MeriCheck A1c-CRP.cdr

Transcription

MeriCheck A1c-CRP.cdr
TM
TM
TM
TM
TM
TM
Meril Diagnostics
Emerging from a lineage of successful business enterprise, Meril
Diagnostics is an in-vitro diagnostic arm of the multi million dollar group
MNC.
Meril Diagnostic’s core objective is to design, manufacture and
distribute, clinically relevant, state of the art and best in class analyzers
and reagents to alleviate human suffering and improve Quality of Life.
Corporate Office
Meril Training Academy
While innovations and advancements play a vital role in
contributing towards better health of the society, a larger role
also lies in educating and imparting training to pathologists,
clinicians, technicians and other members of the medical
fraternity.
Meril's corporate office sits proud ensconced within the serene hill sides
of Chala town; located 150 kms north of Mumbai at Vapi
Manufacturing
Meril's Training Academy is a world class, first of its kind
institution that offers both practicing professionals and
students hands on training and knowledge.
300,000 sq feet state of the art manufacturing, research and
development facility located at Vapi for Diagnostics, Orthopaedics,
Endo-surgery equipments and Cardiovascular, comprising a team of
designers, engineers, chemists, microbiologists and R&D scientists.
Modernistic, contemporary academy with Hands on Trainings,
Simulators, Live Case Learning, Distance learning, Hard-ware
play rooms, Libraries, Cadaver and Animal models.
Boronate Affinity (POCT)
High quality Boronate Affinity (HbA1c) and sandwich immunoassay (CRP) principle
Results available in 7sec
3.5 inch Graphic Color Touch LCD
Sample type - Whole blood (Capillary and Venous), Serum, Plasma (CRP test)
Sample volume - 5 µl
Automatic Tray loading
Maximum of 300 test results can be saved in the memory space
Built-in Thermal printer
Optional Barcode reader
USB, RS-232 Interfacing
Voice guide and instruction
5 µl
Tiny drop of blood
using capillary tube
7sec.
Immediate results
available within 7 sec.
(Total Assay Time : 3 min.)
Mericheck A1c/CRP analyzer is an in-vitro diagnostic, POC device with
high performance that uses a Boronate Affinity principle for HbA1c
testing and sandwich immunoassay principle to test CRP; a sensitive
marker of inflammation.
Principle
Glycated haemoglobins (GHb) and glycated plasma proteins (GPP)
differ from non-glycated proteins by the attachment of a sugar
moiety(s) at various binding sites by means of a ketoamine bond. GHb
and GPP thus contain 1,2-cis-diol groups not found in non-glycated
proteins, which provide the basis for separation of glycated and nonglycated components by boronate affinity chromatography.
Ease of Operation
is integrated with Auto Guide Operation
and with Automatic tray feeding to ensure ease of operation.
Sampling
Sample type- Whole blood (Capillary and Venous), Serum, Plasma
(CRP test)
Sample volume- 5 µl
In case of CRP testing, on the test well of the device there is a
membrane coated with immobilized CRP-specific monoclonal
antibodies. A diluted sample is applied to the test device. When the
sample flows through the membrane, the CRP are captured by the
antibodies. CRP trapped on the membrane will then bind the goldantibody conjugate added, in a sandwich-type reaction. Unbound
conjugate is removed from the membrane by the washing solution. A
paper layer underneath the membrane absorbs excess liquid. In the
presence of a pathological level of CRP in the sample, the membrane
appears redpurple with color intensity proportional to the CRP
concentration of the sample.
incorporates both USB and RS232
interface to connect the instrument with the computer.
Display
This makes sure that the instrument can be connected, no matter which
interfaces are installed.
Fast and reliable
has short result measuring time with
immediate results available within 7 seconds. Total assay time is of 180
seconds.
Memory
has storage capacity of 300 test results.
Connectivity
user friendly software enables
operator to program protocols
with ease using 3.5 inch
graphic user interface
(GUI) colour touch LCD.
Built in printer
is integrated with thermal printer to print
the respective results of HBA1c and CRP.
Measuring Principle
Boronate Affinity (A1c) & Sandwich immunoassay (CRP)
Total Assay Time
< 180 sec
Measurement time
7 sec
Measurement range
4 -15% (A1c)
Sample Volume
5 µl
Sample Type
Whole blood (Capillary and Venous), Serum, Plasma (CRP test)
Display
3.5 inch Graphic Color Touch LCD
Memory
300 Test Results
Printer
In-built thermal printer
External interface
USB : Use for upgrading the firmware
RS-232 : Use for Barcode Reader
Input Voltage (DC)
+ 12 V, Dedicated AC adaptor
Electricity Consumption
12W(Max)
Main Adapter
Separate AC to DC mains adapter
Input
100 ~ 240V
Output
12V / 2A
Operating Temperature
5 ~ 35°C / 59 ~ 95°F
Relative Humidity
15 ~ 75% RH
Altitude
3,000m(Max)
Storage Temperature
10 ~ 60°C / 14 ~ 140°F
Dimensions
178 mm (W) x 195 mm (L) x 75 mm (H)
Weight
Approx. 730g
TM
TM
TM
HbA1c Kit (POCT)
30 Tests
MCKCRP-01
CRP Kit (POCT)
30 Tests
TM
TM
TM
D1 - D3, Survey No.
135/2/B & 174/2, Meril Park,
Muktanand Marg, Chala,
Vapi - 396191, Gujarat, India.
+91 22 30732400
Tuzla
MAC|BROCHURE|20140530|V.10|IND
MCKA1C-01
Customer Care: 1-800-266-3745 (Toll Free)