Release Notes for TRICAD MS 2015.0 for MicroStation V8i
Transcription
Release Notes for TRICAD MS 2015.0 for MicroStation V8i
Daimler AG Release Notes for TRICAD MS 2015.0 Introduction Cover sheet 1. Introduction 1.1 Cover sheet Release Notes for TRICAD MS 2015.0 for MicroStation V8i Release November 2015 Status: Author: Status 30/11/2015 30/11/2015 Venturis GmbH Page 1 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Introduction Table of Contents 1.2 Table of Contents 1. Introduction................................................................................................................ 1 1.1 1.2 Cover sheet.............................................................................................................................. 1 Table of Contents ................................................................................................................... 2 2 Software Functionalities/Bugfixing TRICAD MS TGA Modules ........................ 4 2.1 2.1.1 2.1.2 2.1.3 2.1.4 2.1.5 2.1.6 2.1.7 2.1.8 2.1.9 2.1.10 2.1.11 2.1.12 2.2 2.2.1 2.2.2 2.2.3 2.2.4 2.2.5 2.2.6 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 2.3.6 2.3.7 2.3.8 2.4 2.4.1 2.4.2 2.4.3 2.4.4 2.4.5 2.5 2.5.1 2.5.2 2.6 2.6.1 2.6.2 2.7 2.7.1 2.7.2 2.7.3 2.7.4 2.7.5 2.7.6 2.7.7 General .................................................................................................................................... 4 Adopt connection values................................................................................................................... 4 Placing couplings .............................................................................................................................. 4 Parametric dummy valve .................................................................................................................. 5 Elbow material supplements ............................................................................................................. 6 Tyco material designations ............................................................................................................... 8 3D General: Insulation labelling ....................................................................................................... 9 Labelling tool variable height at storey .......................................................................................... 10 Write coordinates ............................................................................................................................ 11 Annotation scaling in all 3D modules............................................................................................. 12 Change/extend texts in cell ............................................................................................................. 14 Read out user data masks ................................................................................................................ 15 Arguments for report ...................................................................................................................... 16 TRICAD MS 3D Heating .................................................................................................... 18 Piping network calculation with SOLAR Computer ...................................................................... 18 Entries counter ................................................................................................................................ 19 Change + rotate radiator valves ...................................................................................................... 19 Differential pressure gauge ............................................................................................................. 20 Industrial thermometers, vertical/90° angle .................................................................................... 21 Puddle flanges ................................................................................................................................. 22 TRICAD MS 3D Ventilation:.............................................................................................. 23 Segmented bend / flange representation ......................................................................................... 23 Air type combo box now also with designation.............................................................................. 24 Insert offset in the plan view........................................................................................................... 25 Connecting ducts with rivet plate and T-piece ............................................................................... 26 New features in 3D Ventilation Positioning ................................................................................... 28 Free placing of components: ........................................................................................................... 28 Connecting two ducts: .................................................................................................................... 30 End for parametrics can now be defined: ....................................................................................... 31 TRICAD MS 3D Plumbing ................................................................................................. 32 Drinking water calculation with SOLAR computer ....................................................................... 32 Surface drains ................................................................................................................................. 33 Kitchen sinks .................................................................................................................................. 34 Continuous flow water heater ......................................................................................................... 35 SupraLine glass piping special components ................................................................................... 36 TRICAD MS 3D Sprinkler.................................................................................................. 37 Sprinkler replacement suspended -> standing ................................................................................ 37 SpriCALC: Actual effective area .................................................................................................... 38 TRICAD MS TGA schematic ............................................................................................. 39 Exchange cells ................................................................................................................................ 39 Schematic symbols adapted ............................................................................................................ 40 TRICAD MS 3D Electrical.................................................................................................. 42 Busbars KTA3200 busbar distributor ............................................................................................. 42 Busbars KTA3200 angled boxes .................................................................................................... 43 KTB0324FA end cover................................................................................................................... 43 Busbars KTB fastenings ................................................................................................................. 44 Move new switch strand ................................................................................................................. 44 TRAFO removal direction .............................................................................................................. 45 Lamp spacing in strip lighting ........................................................................................................ 46 3 Software functionalities/bugfixing TRICAD MS Factory Planning modules ... 47 Status 30/11/2015 Page 2 of 77 pages Daimler AG 3.1 Release Notes for TRICAD MS 2015.0 Introduction Table of Contents TRICAD MS equipment layout .......................................................................................... 47 3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 3.1.6 3.1.7 3.1.8 3.1.9 3.1.10 3.1.11 3.1.12 3.1.13 3.1.14 3.1.15 3.1.16 3.1.17 Axial grid with mesh dimensions ................................................................................................... 47 Automatic start of the paint layout ................................................................................................. 49 Read in XML data sets again .......................................................................................................... 50 Entry of commas in decimal fields ................................................................................................. 50 Integrate pumps and vessels additionally into Media toolbox ........................................................ 50 Error in "Modify work platform" function rectified ....................................................................... 50 Error in "Store robot" function rectified ......................................................................................... 51 Bumper extension to Car Configurator ........................................................................................... 52 Area designation function extension............................................................................................... 54 Edge markings extension ................................................................................................................ 55 Separating by fence, partition wall ................................................................................................. 56 Connect two fences, partition walls using corner ........................................................................... 57 Connecting two fences, partition walls using additional element ................................................... 58 Lengthen or shorten fence, partition wall ....................................................................................... 59 Place, change, define system walls ................................................................................................. 60 Place, change, define mobile walls ................................................................................................. 62 Additional manipulators ................................................................................................................. 63 3.1.17.1 3.1.17.2 3.1.17.3 3.1.17.4 3.1.17.5 3.1.17.6 3.1.17.7 3.2 3.2.1 Manipulators for crane rails ...................................................................................................................... 63 Manipulator for trolleys ............................................................................................................................ 64 Manipulator and tool ................................................................................................................................. 65 Support column manipulators ................................................................................................................... 65 Cantilever arm manipulators ..................................................................................................................... 66 Wall-bracket manipulators ........................................................................................................................ 67 Ceiling column manipulators .................................................................................................................... 69 TRICAD MS stage module.................................................................................................. 70 Definition of wind bracings ............................................................................................................ 70 4 Changes in DAIMLER_ENV TGA modules ........................................................ 72 4.1 4.1.1 4.2 4.2.1 TRICAD MS TGA General ................................................................................................ 72 New levels for interference contours and general equipment ......................................................... 72 TRICAD MS Electrical ....................................................................................................... 73 New lights in the cell selector ......................................................................................................... 73 5 Changes to DAIMLER_ENV factory planning modules..................................... 74 5.1 5.1.1 5.1.2 5.1.3 5.1.4 5.1.5 5.2 5.2.1 TRICAD MS Module Layout.............................................................................................. 74 Cell selector extended ..................................................................................................................... 74 New function Manipulators/Handling devices integrated .............................................................. 74 New system walls and mobile walls function integrated ................................................................ 74 New function Parametric pumps integrated .................................................................................... 74 New function Parametric vessels integrated ................................................................................... 75 TRICAD MS stage ............................................................................................................... 76 New function for wind braces integrated ........................................................................................ 76 Status 30/11/2015 Page 3 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General 2 Software Functionalities/Bugfixing TRICAD MS TGA Modules 2.1 General 2.1.1 Adopt connection values New tick in the settings window – Do not query connection values when connecting – always accept without query 2.1.2 Placing couplings Set flange/gaskets/couplings – mask has been extended by type selection Status 30/11/2015 Page 4 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General 2.1.3 Parametric dummy valve New parametric dummy valve in the cell selector: Status 30/11/2015 Page 5 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General 2.1.4 Elbow material supplements Elbows for 90° and 45° with radius 500 have been added in DIN1127 stainless steel: Status 30/11/2015 Page 6 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General Elbows with radius 340 degrees for 1/8” and 1/ 4” have been added in DIN 10225 galvanised material Status 30/11/2015 Page 7 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General 2.1.5 Tyco material designations The moulded parts elbows, T-pieces and reducers have been added to the material selection in line with data sheet TFP1815. Status 30/11/2015 Page 8 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General Additions to the T-pieces: Adjustment of the dimensions in the reducers: 2.1.6 3D General: Insulation labelling Insulation properties can also be labelled: With the argument ${ISOL_BEZ}, the entire designation is used. With the arguments ${ISOL_BEZ1},${ISOL_BEZ2}, the labelling is used according to the subdivision. Status 30/11/2015 Page 9 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General 2.1.7 Labelling tool variable height at storey Height: Top edge, Bottom edge The height labelling for ducts, trays, pipes is produced via the following variables. Absolute at 0.0: ${OKK} ${UKK} ${MA} Top edge absolute at 0.0 Lower edge absolute at 0.0 Axis absolute at 0.0 referred to storey: ${OKK_STK_D} ${UKK_STK_D} ${MA_STK_D} Top edge of storey, distance from ceiling Lower edge of storey, distance from ceiling Axis of storey, distance from ceiling ${OKK_STK_B} ${UKK_STK_D} ${MA_STK_B} Top edge of storey, distance from floor Lower edge of storey, distance from floor Axis on storey, distance from floor The storey is read from the object. Status 30/11/2015 Page 10 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General 2.1.8 Write coordinates ${P2}, ${P2:0}, ${P2:0:mm} ${P2.X}, ${P2.X:0}, ${P2.X:0:mm} Example: ${P2.X:3:m} P2 ... P2 of element. (P, P2...) This would be the connection coordinate in the case of a nozzle. If only P2 stands there, X,Y,Z is set as label. 12.3,3.1,123.4 P2.X --> If X, Y, Z are present, the X, Y, or Z coordinate will be written. :3 ... Number of places after the decimal point, 0, 1, 2, 3... 12, 12.3, 12.34, 12.345 :m ... Coordinate in metres. (m, cm, mm) mm with 0 places after the point Status 30/11/2015 Page 11 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General 2.1.9 Annotation scaling in all 3D modules The is supported for labelling in all 3D modules! Procedure: Create sheet model with “Annotation scaling” … If labelling or dimensioning is now done, the TRICAD-MS texts adjust according to the factor – so 2.5 times greater in this case Status 30/11/2015 Page 12 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General Example for switch is Switched off! Example for switch is Switched on! Status 30/11/2015 Page 13 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General 2.1.10 Change/extend texts in cell Display all text numbers – the numbers of all texts in the cell are shown Status 30/11/2015 Page 14 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General 2.1.11 Read out user data masks The user data masks are read out again also with MODUL_SKEY and MODUL_SKEYF: IMPORTANT: Always with MODULE! In the example, the valve in the “HEAT” module has the following KEYS: Firstly, the MODUL_SKEY is searched for: M_addTo_HEAT_VGFL If MODUL_SKEY is not found, a search is made for MODUL_SKEYF: M_addTo_HEAT_VALVE and further search made using data masks + KBZ..... as before. Status 30/11/2015 Page 15 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General 2.1.12 Arguments for report With the MEDK argument in the report, the short designation (KBZ) of the medium is read out and written into the report. Select argument or enter by hand and define column header with Name. Status 30/11/2015 Page 16 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules General Possible selection list: In this example, the full and short medium designations are issued in the report. Status 30/11/2015 Page 17 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Heating 2.2 TRICAD MS 3D Heating 2.2.1 Piping network calculation with SOLAR Computer A complete nom. diameter, pressure loss calculation and valve design can be carried out for TRICAD-MS 3D heating pipe networks. The established calculation program SOLAR-COMPUTER heating pipe network from SOLAR-COMPUTER GmbH is used for the core calculation. Short description: A 3D TRICAD-MS heating pipe network consisting of pipes, pumps, valves, radiators, reducers, elbows is compiled, beginning with the start pipe. Many default values for pipes, valves, radiators, pumps and components can be automatically taken as a basis. All designations for valves, pipe material, calculation strategies and other items are so defined that the SOLAR-COMPUTER heating pipe network calculation can directly process these values. In the SOLAR-COMPUTER heating pipe network calculation, all transferred values can certainly be modified, but all necessary values are always transferred so that the network read in can be directly calculated. Two calculation modes are possible: sizing and recalculation. In the sizing mode, TRICAD-MS does not transfer nom. diameters to SOLAR-COMPUTER heating pipe network calculation so that an optimum network is calculated whose nom. diameters and insulation thicknesses can be subsequently displayed in TRICAD-MS and can be adopted as an option. In the recalculation mode, pressure losses, flow velocities, heat losses, etc. are calculated, displayed in TRICAD-MS and can be taken over into the data masks. The results of the calculation can be displayed and adopted into the data masks. A calculation log is issued by the SOLAR-COMPUTER heating pipe network calculation in a form that is acceptable to the authorities. Status 30/11/2015 Page 18 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Heating 2.2.2 Entries counter The entries for all counters have been re-sorted in the cell selector. 2.2.3 Change + rotate radiator valves The “Change radiators” function has been extended by the following functions Change + rotate valves Status 30/11/2015 Page 19 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Heating 2.2.4 Differential pressure gauge A differential pressure gauge with DN8 connections is included in the range of measurement valves. Status 30/11/2015 Page 20 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Heating 2.2.5 Industrial thermometers, vertical/90° angle Industrial thermometers from the SUKU company were added to the measurement valves: Status 30/11/2015 Page 21 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Heating 2.2.6 Puddle flanges Puddle flanges from Frank GmbH have been included as construction elements. Status 30/11/2015 Page 22 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Ventilation: 2.3 TRICAD MS 3D Ventilation: 2.3.1 Segmented bend / flange representation Correction of the representation of flanges on a segmented bend. Old: NEW: Status 30/11/2015 Page 23 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Ventilation: 2.3.2 Air type combo box now also with designation In the settings, the selection according to air type is supplemented by the designations. Status 30/11/2015 Page 24 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Ventilation: 2.3.3 Insert offset in the plan view In the top / plan view, mostly set as layout, the Insert Offset function can be applied. Status 30/11/2015 Page 25 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Ventilation: 2.3.4 Connecting ducts with rivet plate and T-piece Procedure: 1. Click pipe/duct. That is ALWAYS the object to be connected! 2. Click continuous duct, pipe. Status 30/11/2015 Page 26 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Ventilation: The two ducts, pipe-duct, pipe-pipe are connected. The following objects can also be connected using this function. Pipe to pipe Pipe to duct Status 30/11/2015 Page 27 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Ventilation: 2.3.5 New features in 3D Ventilation Positioning Without stop in separators and branches 2.3.6 Free placing of components: The CLW value has been entered in the cell selector of the components. This means that the window for entering the height is displayed during the placement. The reference edge in the component window can now be selected, e.g. duct top edge. Status 30/11/2015 Page 28 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Ventilation: When freely placing, i.e. not connected to the duct, the component is therefore correctly placed – 60mm below the ceiling in the example. Status 30/11/2015 Page 29 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Ventilation: 2.3.7 Connecting two ducts: New query as to whether the lengths of the duct are not to be changed. Set an elbow at the beginning/end! OK: The lengths of the ducts are not changed. NO: End of duct is corner of elbow (as before). Ducts are therefore shortened. Status 30/11/2015 Page 30 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Ventilation: 2.3.8 End for parametrics can now be defined: Prompt “Define end” “Define end” The elements are queried step-by-step. Element is end: The strand is parametrised up to this element. Further: The next element is displayed. Cancel: No parametrics! Status 30/11/2015 Page 31 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Plumbing 2.4 TRICAD MS 3D Plumbing 2.4.1 Drinking water calculation with SOLAR computer Left: MicroStation Right: SOLAR-COMPUTER drinking water network calculation A complete nom. diameter, pressure loss calculation can be carried out for TRICAD-MS 3D drinking water pipe networks. The established program SOLAR-COMPUTER drinking water calculation from SOLARCOMPUTER GmbH is used for this. A TRICAD-MS 3D drinking water piping network consisting of pipes, elbows, reducers, valves and consumers (single and mixed consumers) is compiled, beginning with the start pipe (= house water connection point). The data read in can be subsequently transferred to an ASCII file that is imported from the SOLAR-COMPUTER drinking water calculation and then calculated. If no nom. diameters have been exported from the CAD model to the SOLAR-COMPUTER drinking water calculation, SOLARCOMPUTER drinking water program calculates the optimum nom. diameters and transfers these in an ASCII file to TRICAD-MS. TRICAD-MS can now mark all elements with too large or too small nom. diameters. The calculated nom. diameters are (as also in the TRICAD-MS heating pipe network calculation) adopted into the data mask. A calculation log from the SOLAR-COMPUTER drinking water calculation program issued in a form acceptable to the authorities Status 30/11/2015 Page 32 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Plumbing 2.4.2 Surface drains The selection of surface drains has been extended. Status 30/11/2015 Page 33 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Plumbing 2.4.3 Kitchen sinks In the selection of sanitary objects, kitchen sinks with one and two basins have been included. Status 30/11/2015 Page 34 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Plumbing 2.4.4 Continuous flow water heater Continuous flow water heaters have been included in the selection for water heaters. Status 30/11/2015 Page 35 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Plumbing 2.4.5 SupraLine glass piping special components Special components in the SupraLine which uses borosilicate glass 3.3 have been added to the existing QVF® piping. Status 30/11/2015 Page 36 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Sprinkler 2.5 TRICAD MS 3D Sprinkler 2.5.1 Sprinkler replacement suspended -> standing Setting sprinklers from standing to suspended via the function “Exchange cell” – Set tick at new variant “Retain cell position e.g. sprinkler”. Change sprinkler from standing to suspended. Switch MUST be on. Status 30/11/2015 Page 37 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Sprinkler 2.5.2 SpriCALC: Actual effective area The IDAT sprinkler calculation has been extended so that area defined by a fence (in which the switchedon sprinklers are located) is now transferred to IDAT as the actual effective area. Here an example: OLD: NEW: It can be seen that IDAT has naturally changed the calculated minimum water flow produced. The product of effective area and minimum water flow remains the same. Status 30/11/2015 Page 38 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS TGA schematic 2.6 TRICAD MS TGA schematic 2.6.1 Exchange cells The “Exchange cells” function is now also available in the TGA schematic. Status 30/11/2015 Page 39 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS TGA schematic 2.6.2 Schematic symbols adapted The schematic symbols for smoke and fire dampers as well as overflow dampers have been adapted in the ventilation schematic: Status 30/11/2015 Page 40 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS TGA schematic The symbols for components in the 3D Ventilation module have also been supplemented: Butterfly valve and pressure reducer have been added for the Heating schematic. Status 30/11/2015 Page 41 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Electrical 2.7 TRICAD MS 3D Electrical 2.7.1 Busbars KTA3200 busbar distributor The elements are located in “Placing busbars”: KTA3200EH740 busbar distributor 4000 mm with 3 branch points KH KTA3200EH720 busbar distributor 2000 mm with 3 branch points KH KTA3200TP710SP element for converting outer conductor (busbar distributor for changing the phase) KTA3200TN710SP element for converting neutral conductor TN (busbar distributor for changing the N phase) Status 30/11/2015 Page 42 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Electrical 2.7.2 Busbars KTA3200 angled boxes KTA3200LP7C1 angled box, flat KTA3200LP7C2 angled box, flat KTA3200LP7B2 angled box, flat KTA3200LC7SP angled box, upright 2.7.3 KTB0324FA end cover This element is located in "Place end flange” Status 30/11/2015 Page 43 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Electrical 2.7.4 Busbars KTB fastenings KTB0000ZA1 fixing, horizontal KTB0404ZA4 fixing bracket, horizontal KTB0324ZA5 fixing, vertical KT040A9 fire protection block These elements are located in “Placing accessories” Procedure: click the busbar -> the element can then be moved along the busbar 2.7.5 Move new switch strand A tray (open) containing 2 inner, closed trays is to be moved. The "Move objects" function is used for this. If this switch is on, only one strand is moved… Status 30/11/2015 Page 44 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Electrical 2.7.6 TRAFO removal direction The removal direction of the TRAFO component has been extended by a query on direction. It can either be removed forwards or sideways. Sideways: Forwards: Complete isometric: Status 30/11/2015 Page 45 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software Functionalities/Bugfixing TRICAD MS TGA Modules TRICAD MS 3D Electrical 2.7.7 Lamp spacing in strip lighting The spacing between lamps in [mm] can be defined in the Strip lighting function. Status 30/11/2015 Page 46 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3 Software functionalities/bugfixing TRICAD MS Factory Planning modules 3.1 TRICAD MS equipment layout 3.1.1 Axial grid with mesh dimensions Axial grids can also receive, in addition to the XY representation, vertically arranged axial designations, dimensions and dimensioning lines at the edges. This means that the grids are also visible in printouts of side, front and rear elevations. If, for example, only the beginning of the longitudinal axis is labelled, only a vertical label is shown at the beginning of the longitudinal axis. If all 4 axial grid sides are labelled, vertical labels can also be set up at all 4 sides. If all vertical additional labels are to be created, this must be set in the axial grid definition dialogue or in the data mask. Each vertical additional label can be shown as a mirrored version. The labels and dimension texts can therefore be read from the left or right depending on the set view. Example: Status 30/11/2015 Page 47 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout Mirroring of texts and dimensions: The label shown at the side, separation lines and dimension representation are filled in at 2 levels: Axial grid X-axes side view and axial grid Y-axes front/rear views: These levels are laid down in the axial grid definition: Status 30/11/2015 Page 48 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.2 Automatic start of the paint layout If a customer only has one TRILACK licence (and no DCLT equipment layout licence ), the paint layout program will be started. If all DCLT licences are in use, the paint layout is not to be started automatically if the customer wishes to continue working with the equipment layout. The software decides in this case, on the basis of the program environment used, whether the paint layout program is to be opened: “Is a paint environment set in the Projekt Settings.xml (Application = PAINT) ? ” Yes: the paint layout will be started No: an error message appears “no licence available” Settings.xml Message on missing licence Status 30/11/2015 Page 49 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.3 Read in XML data sets again If the parameters of XML objects were changed before the placing, these altered data are maintained till the end of the layout program. To ensure that all original XML object data are reset, the option “Read in the XML data set again” in the object definition dialogue is clicked. The program then reads again the XML file of the particular object type, e.g. all robot definitions. 3.1.4 Entry of commas in decimal fields If commas instead of decimal points are entered, the program automatically corrects the input and sets the text field cursor after the last character (MicroStation standard behaviour when updating text fields) 3.1.5 Integrate pumps and vessels additionally into Media toolbox The Electrical, Media toolbox has been expanded by 2 new buttons from the paint layout, 3.1.6 Error in "Modify work platform" function rectified If work platforms that deviate in size from the standard have been changed, the currently used left/right width is ignored and the standard widths used. Error rectified Status 30/11/2015 Page 50 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.7 Error in "Store robot" function rectified Various tools and bases are entered in the robot data sets of the Roboter.xml file. This allows special tools / bases to be set for the selected robots. If the user has stored his own robots, the tool/base selection assigned to the robot is not available. The robot XML file has now been extended by 2 additional folders in which standard tools and standard bases can be entered. These standard add-on parts are transferred when storing user-robots in the user XML file. Status 30/11/2015 Page 51 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.8 Bumper extension to Car Configurator Bumper has been added as a new add-on element type. Bumpers found are listed in the “Vehicle add-on elements” definition dialogue: Status 30/11/2015 Page 52 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout Extension to all data masks Example: Bumper, shown in red Example: Bodywork without bumper (bodywork still has to be reworked) Status 30/11/2015 Page 53 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.9 Area designation function extension The label texts can be set once the area designations have been placed,. Area designation and associated labelling text are entered into a graphics group. Definition of preset texts and text parameters Status 30/11/2015 Page 54 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.10 Edge markings extension The label texts can be set once the area designations have been placed: Status 30/11/2015 Page 55 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.11 Separating by fence, partition wall The button of the Fence, Partition-wall toolbox is used for splitting fences and partition walls. The separation region can now be clicked at any points on this fence line. After the clicking of the 2nd split point, the two clicked-on fence segments are shortened and the fences/posts lying in between are removed. End-posts are shown at the new ends. Status 30/11/2015 Page 56 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.12 Connect two fences, partition walls using corner The button of the Fence, Partition-wall toolbox is used for connecting fences and partition walls. Fence chains can be lengthened up to the common intersection point. The fences to be joined are clicked one after the other and then connected together. Defining the corner posts The end post of the first fence to be clicked is used as corner post. In the case of centred fence posts, the corner post is placed exactly at the calculated fence corner. Examples: before after before after Different fence and partition wall types can also be connected to each other. Status 30/11/2015 Page 57 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.13 Connecting two fences, partition walls using additional element The button of the fence, partition-wall toolbox connects two fences, partition walls using an additional element. Fence chains can be connected using an additional fence. The program uses the first clicked fence as standard for creating the connection fence. The fences to be joined are clicked one after the other and then connected together. The data of the first fence to be clicked are used for creating the connecting fence. The end posts of the fences to be connected remain. The connecting fence has no end posts of its own. Example: before before: Status 30/11/2015 after The green fence was clicked first and is used as the connecting fence. after Page 58 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.14 Lengthen or shorten fence, partition wall The button of the Fence, Partition-wall toolbox is used for lengthening or shortening fences and partition walls. All adjacent fences and posts of the same graphic group are read in by the program and regarded as logical fence chain that is shortened or lengthened. The last fence element of the line is used as template for the lengthening. Example: The last element (single wall) is used as template for new walls. The last element and the associated built-in windows are used as template for new walls. Status 30/11/2015 Page 59 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.15 Place, change, define system walls System walls are post/partition-wall combinations with floor rail. The posts can be set up with supporting walls as an option. Any built-in wall parts can be shown in system walls. A ceiling connection strip above the system walls will be shown as an option. A cabin floor and cabin ceiling can be created when the system wall border is closed. Lengths of 0.25m to 3.00m with many different built-in features are placed at the height of 2.55m. Extract from system wall module and data set from the combo boxes as selection: After clicking the placement button or , the following options are available in the placement dialogues: Alignment of the system walls, creating ceiling connection strip and floor rails, show the posts at the beginning and end of the system wall, show supporting walls, showing floor and ceiling panels, additional functions with "System wall individual placement" Example of supporting walls and floor rail: Status 30/11/2015 Page 60 of 77 pages Daimler AG Status 30/11/2015 Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout Page 61 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.16 Place, change, define mobile walls Mobile walls are combinations of building walls and associated built-in parts (windows, doors, etc.). Mobile walls have a predefined length and can be simply placed in a line. Ceiling rails and floor rails, and hangers and floor storage are not displayed. Selection of mobile wall module and data set from the combo boxes: When placing freely between the corner points, the mobile walls are placed directly together in sequence. The last wall is possibly shortened to achieve the exact overall length. Status 30/11/2015 Page 62 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.17 Additional manipulators 3.1.17.1 Manipulators for crane rails The button of the crane rail toolbox Manipulators can be attached to individual crane rails as well as to single-girder and double-girder crane rails. These are put together from trolley, manipulator and holder/tool. Status 30/11/2015 Page 63 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.17.2 Manipulator for trolleys Status 30/11/2015 Page 64 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.17.3 Manipulator and tool 3.1.17.4 Support column manipulators After clicking the "Place manipulator" button manipulator parameters. Status 30/11/2015 a dialogue field opens showing a variety of Page 65 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.17.5 Cantilever arm manipulators After clicking the "Place manipulator" button manipulator parameters: Status 30/11/2015 a dialogue field opens showing a variety of Page 66 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout The cantilever arm manipulator data mask contains the cantilever arm length, O, as additional parameter. 3.1.17.6 Wall-bracket manipulators After clicking the "Place manipulator" button manipulator parameters: Status 30/11/2015 a dialogue field opens showing a variety of Page 67 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout The wall-bracket manipulator data mask contains the cantilever arm length, O, as additional parameter. Status 30/11/2015 Page 68 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.17.7 Ceiling column manipulators After clicking the "Place manipulator" button manipulator parameters: a dialogue field opens showing a variety of The ceiling column manipulator data mask contains the column length, O, as additional parameter. Status 30/11/2015 Page 69 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS stage module 3.2 TRICAD MS stage module 3.2.1 Definition of wind bracings Wind bracing profile Wind bracings are bracings for truss girders that absorb and transfer horizontal wind forces. The stage module creates steel girders for surrounds, floor profiles, supports, balustrades, stairs etc. There are no specific entry dialogues or properties for these objects. Standard steel girders and wind bracing steel girders are produced using the same functions. There are however different graphic properties (3D level, 3D colour, 3D line values) and different data mask location entries. All change, new structure, and SDNF export functions differentiate between steel girders and wind braces. 1. File env\db\bm\bm_settings.cfg Extension of all property sets concerning wind braces: (level, colour, line values, visibility) Status 30/11/2015 Page 70 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Software functionalities/bugfixing TRICAD MS Factory Planning modules TRICAD MS stage module 2. File env\db\bm\bmSDNFconfig.xml insert in all export nodes Attribute “Windbrace 1” (= Export of wind brace profiles to the SDNF file) 3. File tribm.cfg new optional control entries available “>UPDATEVIEW 1” and “>NOUPDATEVIEW 0” Status 30/11/2015 Page 71 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Changes in DAIMLER_ENV TGA modules TRICAD MS TGA General 4 Changes in DAIMLER_ENV TGA modules 4.1 TRICAD MS TGA General 4.1.1 New levels for interference contours and general equipment New levels have been created for the placing of 3D interference spaces and various 3D equipment items in all TGA trades: Example from the CAD guidelines: The levels are to be kept neutral. The exact occupancy is to be discussed in the projects. Status 30/11/2015 Page 72 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Changes in DAIMLER_ENV TGA modules TRICAD MS Electrical 4.2 TRICAD MS Electrical 4.2.1 New lights in the cell selector New strip-lighting lamp SITECO_DUS_5LJ14531R_asymmetric S40 Status 30/11/2015 Page 73 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Changes to DAIMLER_ENV factory planning modules TRICAD MS Module Layout 5 Changes to DAIMLER_ENV factory planning modules 5.1 TRICAD MS Module Layout 5.1.1 Cell selector extended The cell selector has been extended in some areas. Please set the filter “Release 11/2015" in the cell selector for further details. 5.1.2 New function Manipulators/Handling devices integrated The new functions for placing manipulators and handling devices have been adopted in the Daimler settings files of TRICAD MS Layout. The button of the crane rail toolbox 5.1.3 New system walls and mobile walls function integrated The new functions for placing system walls and mobile walls have been adopted in the Daimler settings files of TRICAD MS Layout. 5.1.4 New function Parametric pumps integrated The new function for placing parametric pumps has been adopted in the Daimler settings files of TRICAD MS Layout. Status 30/11/2015 Page 74 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Changes to DAIMLER_ENV factory planning modules TRICAD MS Module Layout 5.1.5 New function Parametric vessels integrated The new function for placing parametric vessels has been adopted in the Daimler settings files of TRICAD MS Layout. Status 30/11/2015 Page 75 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Changes to DAIMLER_ENV factory planning modules TRICAD MS stage 5.2 TRICAD MS stage 5.2.1 New function for wind braces integrated The new function for placing wind braces vessels has been adopted in the Daimler settings files of TRICAD MS stage module. Any steel girder can now be defined as a wind brace: A new level for the wind braces has been created: Status 30/11/2015 Page 76 of 77 pages Daimler AG Release Notes for TRICAD MS 2015.0 Changes to DAIMLER_ENV factory planning modules TRICAD MS stage The settings files and the CAD guidelines have been appropriately extended: The wind braces have also been taken into account in the SDNF data exchange: Status 30/11/2015 Page 77 of 77 pages
Similar documents
Release Notes for TRICAD MS 2014.8 for MicroStation V8i Release
Several robots on a common guide rail ............................................................................................... 42 Axial grid function revised. ..................................
More information