Release Notes for TRICAD MS 2014.8 for MicroStation V8i Release

Transcription

Release Notes for TRICAD MS 2014.8 for MicroStation V8i Release
Daimler AG
Release Notes for TRICAD MS 2014.8
Introduction
Cover sheet
1. Introduction
1.1 Cover sheet
Release Notes for TRICAD MS 2014.8
for MicroStation V8i
Release May 2015
Status:
Author:
04/05/2015
Venturis GmbH
Status 04/05/2015
Page 1 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Introduction
Table of Contents
1.2 Table of Contents
1. Introduction ............................................................................................................1
1.1
1.2
Cover sheet ............................................................................................................................. 1
Table of Contents ................................................................................................................... 2
2 Software Functionalities/Bugfixing TRICAD MS TGA Modules ...........................4
2.1
General .................................................................................................................................... 4
2.1.1
2.1.2
2.1.3
2.1.4
2.1.5
2.2
Fix text position in cell ............................................................................................................................ 4
Captioning of penetrations ..................................................................................................................... 4
Volume of pipelines ................................................................................................................................ 5
Split pipes via shape, line, polyline ........................................................................................................ 6
Insulation extended with ENEV .............................................................................................................. 7
TRICAD MS Heating................................................................................................................ 8
2.2.1
2.2.2
2.2.3
2.2.4
2.2.5
2.3
Length of branch saddles ....................................................................................................................... 8
Storz couplings........................................................................................................................................ 9
Drives for BOAX-SF butterfly valve...................................................................................................... 10
Shutoff valve BOA-SuperCompact ....................................................................................................... 11
WILLBRANDT Rubber expansion joint Type 50 ................................................................................... 12
TRICAD MS Plumbing ........................................................................................................... 13
2.3.1
2.3.2
2.3.3
2.4
Viega Sanpress moulded parts ............................................................................................................ 13
Reworking of PE pipe material ............................................................................................................. 15
SupraLine glass piping material ........................................................................................................... 16
TRICAD MS Ventilation ........................................................................................................ 19
2.4.1
2.5
Diverse new outlets and penetrations ................................................................................................. 19
TRICAD MS Electrical ........................................................................................................... 22
2.5.1
2.5.2
2.6
New Chiaro 2 moisture-proof lights..................................................................................................... 22
New Parametric Lights function........................................................................................................... 23
TRICAD MS Sprinkler ........................................................................................................... 27
2.6.1
2.6.2
2.6.3
2.6.4
2.6.5
2.6.6
Welding neck with loose flange of type "VB" ...................................................................................... 27
Clamps extended .................................................................................................................................. 28
Aerator and bleed valves from AWG company.................................................................................... 29
Feed valve DIN 14461 Part 4 ............................................................................................................... 30
Hose connecting valve for extinguishing water pipes ........................................................................ 31
3D Sprinkler: Wall hydrant Type F Figure 112 01 ............................................................................... 32
3 Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules .. 33
3.1
TRICAD MS equipment layout ............................................................................................. 33
3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
3.1.6
3.1.7
3.1.8
3.1.9
3.1.10
3.1.11
3.1.12
3.1.13
3.1.14
3.1.15
3.1.16
3.1.17
3.1.18
3.1.19
3.1.20
Creating shelving using the graphics group ........................................................................................ 33
Manual workplace top Dialogue control changed .............................................................................. 33
Placing of cell selector: Automatically adopting dimensions as shift values .................................... 34
Manual workplace: set add-on elements in more detail .................................................................... 34
Manual workplace side panel, representation extended.................................................................... 35
Wire-mesh double wing doors .............................................................................................................. 35
Sliding doors as new design for single and double wing doors ......................................................... 36
Extension to placement dialogues ....................................................................................................... 37
Extension to the double door placement dialogue ............................................................................. 37
Extension to the double door definition .............................................................................................. 38
Adopting rotation from the view .......................................................................................................... 39
Inserting elements in railings ............................................................................................................... 39
Extension to parametric shelving racks............................................................................................... 40
Extension to shelving systems, placement dialogue for dimensional drawings ............................... 41
Preview drawings for parametric objects ............................................................................................ 41
Extension to Car-Configurator.............................................................................................................. 41
Extension to robot planning function................................................................................................... 42
Several robots on a common guide rail ............................................................................................... 42
Axial grid function revised. ................................................................................................................... 43
Extending the zone designation functions .......................................................................................... 45
Status 04/05/2015
Page 2 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Introduction
Table of Contents
3.1.21
Automatic captioning of TRICAD-MS cells .......................................................................................... 48
4 Changes in DAIMLER_ENV TGA Modules ........................................................... 49
4.1
4.1.1
4.1.2
4.1.3
4.1.4
4.2
4.2.1
TRICAD MS Electrical ........................................................................................................... 49
New lights .............................................................................................................................................. 49
New components (3D cells) ................................................................................................................. 51
New installation devices (2D symbols) ................................................................................................ 52
Addition of parametric lights to Daimler ENV ..................................................................................... 52
TRICAD MS Plumbing ........................................................................................................... 53
New medium in technical gases .......................................................................................................... 53
5 Changes to DAIMLER_ENV factory planning modules...................................... 54
5.1
5.1.1
5.1.2
5.2
5.2.1
TRICAD MS Module Layout ................................................................................................. 54
Cell selector extended .......................................................................................................................... 54
New vehicle in the Car-Configurator GLA-Class ................................................................................. 54
TRICAD MS module Crane -> Layout .................................................................................. 55
Conversion of an old crane tool to layout of crane functions ............................................................ 55
Status 04/05/2015
Page 3 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
General
2 Software Functionalities/Bugfixing TRICAD MS TGA Modules
2.1 General
2.1.1 Fix text position in cell
2.1.2 Captioning of penetrations
New settings in attributes.cfg for the penetration captions
[DBTXT_NO_LNG] WFR;WDR;DDR
Status 04/05/2015
Page 4 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
General
2.1.3 Volume of pipelines
The volume of pipelines can now also be evaluated via the argument VOL_RM [m3]
. Previous argument VOL_R [mm3].
Status 04/05/2015
Page 5 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
General
2.1.4 Split pipes via shape, line, polyline
New function – split lines via shape/polyline
Status 04/05/2015
Page 6 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
General
2.1.5 Insulation extended with ENEV
The new ordinance on insulation has been implemented in the ENEV selection and can be selected from
the TGA Trades location:
Status 04/05/2015
Page 7 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Heating
2.2 TRICAD MS Heating
2.2.1 Length of branch saddles
The length of the branch saddle is now adjustable.
Status 04/05/2015
Page 8 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Heating
2.2.2 Storz couplings
Storz couplings with inside thread have been added. The following DN are available:
Status 04/05/2015
Page 9 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Heating
2.2.3 Drives for BOAX-SF butterfly valve
Extended selection of drives for the butterfly valve.
Status 04/05/2015
Page 10 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Heating
2.2.4 Shutoff valve BOA-SuperCompact
The selection of shut-off valves has been extended by the addition of a model from KSB.
Status 04/05/2015
Page 11 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Heating
2.2.5 WILLBRANDT Rubber expansion joint Type 50
Selection of expansion joints extended:
Status 04/05/2015
Page 12 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Plumbing
2.3 TRICAD MS Plumbing
2.3.1 Viega Sanpress moulded parts
Special moulded parts for the material Viega Sanpress were added
Status 04/05/2015
Page 13 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Plumbing
Example of attribute mask:
Status 04/05/2015
Page 14 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Plumbing
2.3.2 Reworking of PE pipe material
Material reworked to correspond to Geberit catalogue
Status 04/05/2015
Page 15 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Plumbing
2.3.3 SupraLine glass piping material
QVF® piping made from borosilicate glass 3.3 of the SupraLine product line included.
Considerably more DNs defined in this material. But not all individual parts have been made for each DN.
Elbows, reducers, Tees and cross pieces have been stored.
Status 04/05/2015
Page 16 of55
Daimler AG
Status 04/05/2015
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Plumbing
Page 17 of55
Daimler AG
Status 04/05/2015
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Plumbing
Page 18 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4 TRICAD MS Ventilation
2.4.1 Diverse new outlets and penetrations
New outlets from Krantz have been included:
Radial outlet RA-N with types D and E
Status 04/05/2015
Page 19 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Ventilation
Outlet type Puridrall, round and angular
Outlets in the XML selection:
The version with square connection at the side
could not be illustrated with the XML
outlets and
is therefore stored in the cell selector.
Status 04/05/2015
Page 20 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Ventilation
Outlet type Opticlean, round and rectangular
Outlets in the XML selection:
Status 04/05/2015
Page 21 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Electrical
2.5 TRICAD MS Electrical
2.5.1 New Chiaro 2 moisture-proof lights
Addition of moisture-proof lights to the models from Zumtobel.
Status 04/05/2015
Page 22 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Electrical
2.5.2 New Parametric Lights function
Manufacturer + type can be predefined in the file
"parametrische_leuchten.cfg".
Dimensions of the lamp.


DN: Diameter of the round lamp
DN-2D: the diameter of the 2D cell can be explicitly
defined here.
Attributes:
Identifier, circuit and IP address
If the "+" switch is on, the IP address is increased
by 1 after the placing!
Graphics of the light. The graphics consist of 2D and
3D cells
Emergency lighting: If the cell for emergency
lighting is defined in "Leuchten_grafik.cfg", the
symbol for the emergency lighting can be displayed
here.
Reference point: Place cell with datum point
Transfer active light to strip light function
The associated files are:
Configuration files: parametrische_leuchten.cfg; Leuchten_grafik.cfg
Application: cellsel_anwendung.cfg (attributs.cfg)
Cell library
Change attributes of the light via INFOMASKE (assign New Graphic, Change dimensions... etc..)
Status 04/05/2015
Page 23 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Electrical
Procedure for placing:
Select light or enter dimensions and define 3D/2D Graphic
The light hangs on the cursor (otherwise select reference point!)
The placement window is opened:
Set storey, Z-coordinate, angle of rotation,
reference edge, application (colour + level)
.
Set light via datum point.
Status 04/05/2015
Page 24 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Electrical
Change attributes of the light via INFOMASKE
These buttons are stored with functions.
All are filled in again via the configuration files.
--> OK --> The light is reconstructed with the new dimensions/graphic.
Status 04/05/2015
Page 25 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Electrical
Transfer active light to strip light function
Procedure:
All attributes of the parametric light are set.
Select
function.
The strip light function is called up. The parametric light is transferred.
All settings such as degree of filling, distance start/end
profile are made.
!!! IMPORTANT: Do not select the light any more....
PARA_LIGHT now stands there. The active parametric
placed!
Select
Status 04/05/2015
and place strip light.
Page 26 of55
and
light is
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Sprinkler
2.6 TRICAD MS Sprinkler
2.6.1 Welding neck with loose flange of type "VB"
The selection of gaskets and flanges has been extended for PE SDR11,17,33 with PN 10,16.
Status 04/05/2015
Page 27 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Sprinkler
2.6.2 Clamps extended
Two types have been included for the Couplings/Pipe clamp/Support function:
Tapping sleeve_Type99_QuickLet
Sprinkler clamp_VTS
The schematic representation in the drawing
Status 04/05/2015
Page 28 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Sprinkler
2.6.3 Aerator and bleed valves from AWG company
Aerator and bleed valves DN 50 acc. to DIN 14463-3 PN 16 for extinguishing water pipe systems, acc. to
DIN 14462 “dry” and “wet/dry” for vertical installation.
Connection: Inlet G2A, overflow G 1 ¼" Housing: red brass
Status 04/05/2015
Page 29 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Sprinkler
2.6.4 Feed valve DIN 14461 Part 4
Feed valve DIN 14461 Part 4 for "dry" riser, PN16, from Minimax
Status 04/05/2015
Page 30 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Sprinkler
2.6.5 Hose connecting valve for extinguishing water pipes
Further feed valves for extinguishing water lines "dry" connecting system Storz or thread
Status 04/05/2015
Page 31 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS TGA Modules
TRICAD MS Sprinkler
2.6.6 3D Sprinkler: Wall hydrant Type F Figure 112 01
Addition to the water extinguishing systems - feed valves
Status 04/05/2015
Page 32 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
3 Software Functionalities/Bugfixing TRICAD MS Factory
Planning Modules
3.1 TRICAD MS equipment layout
3.1.1 Creating shelving using the graphics group
3.1.2 Manual workplace top Dialogue control changed
The box height can only be defined
when the “Closed box” in the context menu is selected.
Status 04/05/2015
Page 33 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
3.1.3 Placing of cell selector: Automatically adopting dimensions as shift values
The dimensions of the currently selected element are taken over into the data fields
3.1.4 Manual workplace: set add-on elements in more detail
At the manual workplace, add-on elements can now be set next to the cell origin with 3 x 3 x 3 reference points.
Status 04/05/2015
Page 34 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
3.1.5 Manual workplace side panel, representation extended
The side panels can now be set with a configurable bevel. The panel height can be entered from the lower edge of the work
top or from the floor level.
3.1.6 Wire-mesh double wing doors
Double doors can now be generated optionally as wire mesh type.
Extension to the definition dialogue
Status 04/05/2015
Page 35 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
3.1.7 Sliding doors as new design for single and double wing doors
Extension of the door definition to include sliding doors (and sliding gates)
Wire mesh doors can be created as wing or sliding doors
Status 04/05/2015
Page 36 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
3.1.8 Extension to placement dialogues
The doors listed in the combobox can be pre-filtered using the “Wing doors”, “Sliding doors”, “Sliding gates” filter. If sliding
doors/gates are placed, the program interchanges the alignment and opening angle symbols.
Extension to the door and wire mesh door data masks.
3.1.9 Extension to the double door placement dialogue
Selection filters and appropriate symbols are also available here.
Status 04/05/2015
Page 37 of55
Daimler AG
3.1.10
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
Extension to the double door definition
Extension to the double door/gate data masks.
Double door examples:
Wire mesh double sliding door in a frame surround
Status 04/05/2015
Page 38 of55
Daimler AG
3.1.11
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
Adopting rotation from the view
When working with rotational views, the rotation of a view can be used as a basis for placement in other views. Some
placement functions did not have this option and have been extended. Axial grids, tables, cabinets, robots, shelving,
containers, container guide rails, trailers, transport vehicles, control cabinets, control consoles and paint module immersion
tanks.
3.1.12
Inserting elements in railings
Extension to the Railing toolbox The railing is always “broken” over its entire height. When moving or deleting built-in parts, the
railing is automatically corrected, as with walls and fences.
Status 04/05/2015
Page 39 of55
Daimler AG
3.1.13
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
Extension to parametric shelving racks
Side and rear panels can be stabilised using diagonal bracing or a panel.
Rack shelves and pallet racks have had a common shelving data mask M_2100 up to now.
The new panel parameters can only be used for rack shelves and are in the new shelf data mask M_2105. There is a new
Settings.xml entry for pallet racks.
Status 04/05/2015
Page 40 of55
Daimler AG
3.1.14
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
Extension to shelving systems, placement dialogue for dimensional drawings
New dimensional drawings to explain the shelving system parameters.
3.1.15
Preview drawings for parametric objects
Extension to all placement dialogues for crane rail objects, vehicles, construction space, captions, instruction text, legends,
escape routes and stages for additional preview images.
Examples:
3.1.16
Extension to Car-Configurator
Manufacturer with icon as pre-filter
Status 04/05/2015
Page 41 of55
Daimler AG
3.1.17
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
Extension to robot planning function
Adjustment to various robot cells so that the displayed base height corresponds to the real height.
Defining the robot base by placement (foundation, slide, slide+rail, none)
The 2D representation of all robots lies on the same level.
3.1.18
Several robots on a common guide rail
Robot and slide are placed on an already existing rail.
AccuDraw is aligned and the new robot can be placed on the rail at a defined distance from the first robot.
Status 04/05/2015
Page 42 of55
Daimler AG
3.1.19
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
Axial grid function revised.
Rotated axial grid Text representation with rotated axial grids remedied; the texts sometimes stood on their heads with very
large angles of rotation.
Rotated longitudinal axis captions If longitudinal axis captions are shown rotated by 90°, the dimension chains now remain
unchanged – and are not rotated as well.
Axial grid crossing point captioning extended by intermediate text
Do not write longitudinal and transverse axis designations directly adjacent to each other
Show axial grid texts optionally with any character set (instead of text style) all 10 text properties extended
Status 04/05/2015
Page 43 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
Definition of the search volume height over the grid square (= grid height)
The value is transferred as height to the axial grid data mask.
Optionally, a standard search area for height can be defined with the axial grid data acceptance if the axial grid does not
possess a height.
Status 04/05/2015
Page 44 of55
Daimler AG
3.1.20
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
Extending the zone designation functions
Additional options for entering polylines (= e.g. clicking the corner points of existing plan views)
New properties, height, volume or wire frame representation, transparency
Status 04/05/2015
Page 45 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
Example: Layout with zone designations in wire frame representation:
or volume representation:
Adopt attributes of zone designations in TRICAD-MS data masks
with information:
Status 04/05/2015
Page 46 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
Designations of nested zones can also be used, e.g. complete building, storeys, rooms, ventilation zones, etc. The information
to be assigned should then however also always be explicit
As with axial grid, a standard height can be defined for the search area if the data masks do not include a height.
Which values of the zone designation are to be entered into the attributes of the search area cells is defined in the
Settings.xml file. As an option, changing the attributes by the user can be deactivated, AreaAttSensitive = 0.
Example: the target attributes cannot be changed
Status 04/05/2015
Page 47 of55
Daimler AG
3.1.21
Release Notes for TRICAD MS 2014.8
Software Functionalities/Bugfixing TRICAD MS Factory Planning Modules
TRICAD MS equipment layout
Automatic captioning of TRICAD-MS cells
The functions for automatic cell captioning have been simplified. The more complex settings can be accessed via “Further
settings”.
Special case: automatic captioning of zone designations with the setting Text reference point =mid-point
The volume mid-point (3D range) is not used here but rather a point is sought that lies on floor level within the area
Status 04/05/2015
Page 48 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Changes in DAIMLER_ENV TGA Modules
TRICAD MS Electrical
4 Changes in DAIMLER_ENV TGA Modules
4.1 TRICAD MS Electrical
4.1.1 New lights

Wall light: BEGA 200 x 200 x 135 mm



Built-in light: RIDI EDLR_150_2000_840_SMB_DALI
Built-in light: RIDI EP_R1X115_30_DA_P_DALI
Built-in light: RIDI VLDF_114_24_DALI

Moisture-proof light: PFAG_T16_R1X145_35_DA_DALI
Status 04/05/2015
Page 49 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Changes in DAIMLER_ENV TGA Modules
TRICAD MS Electrical

Strip light: VLG_R1X115_30_7DA_DALI

Office light: EBRE_LED_414_5200_840_MPS_DALI
Status 04/05/2015
Page 50 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Changes in DAIMLER_ENV TGA Modules
TRICAD MS Electrical
4.1.2 New components (3D cells)




KEBA_KeContact_home
Pedestal
Pedestal_V1_KEBA_KeContact_P20
Pedestal_V2_KEBA_KeContact_P20
Status 04/05/2015
Page 51 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Changes in DAIMLER_ENV TGA Modules
TRICAD MS Electrical
4.1.3 New installation devices (2D symbols)








Alarm light
Reassurance light
Cord switch
Ackn. button
Alarm horn
Duty room display
Mains device
Alarm button

Symbol for fire brigade information centre
4.1.4 Addition of parametric lights to Daimler ENV
The new TRICAD MS function for parametric lights has been integrated into the Daimler ENV and given a
neutral manufacturer designation.
This function is only to be used in exceptional cases when the appropriate light is not available in the cell
selector.
Status 04/05/2015
Page 52 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Changes in DAIMLER_ENV TGA Modules
TRICAD MS Plumbing
4.2 TRICAD MS Plumbing
4.2.1 New medium in technical gases
Ammonia has been introduced as a new medium in TGA Mechanical specialist area, Technical Gases
discipline.
Status 04/05/2015
Page 53 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Changes to DAIMLER_ENV factory planning modules
TRICAD MS Module Layout
5 Changes to DAIMLER_ENV factory planning modules
5.1 TRICAD MS Module Layout
5.1.1 Cell selector extended
The cell selector has been extended in some areas. Please set the filter “Release 05/2015" in the cell selector for further
details.
5.1.2 New vehicle in the Car-Configurator GLA-Class
Status 04/05/2015
Page 54 of55
Daimler AG
Release Notes for TRICAD MS 2014.8
Changes to DAIMLER_ENV factory planning modules
TRICAD MS module Crane -> Layout
5.2 TRICAD MS module Crane -> Layout
5.2.1 Conversion of an old crane tool to layout of crane functions
The previous TRICAD MS Crane module is replaced by the new crane functions of the module TRICAD MS Equipment Layout
To this end, a new layout Daimler Settings Environment (FK) has been created for the crane functions.
Crane files (Transportation Technology specialist area, Crane Systems discipline) are created and processed with immediate
effect using the layout functions. A migration of the old data is not provided for. The CAD data structures (levels, colours etc.)
are retained.
Parametric changes to old objects cannot be made; these must be deleted as required and replaced by new objects.
Status 04/05/2015
Page 55 of55