Tek-CARE® NC300 II Nurse Call System
Transcription
Tek-CARE® NC300 II Nurse Call System
Tek-CARE® NC300 II Nurse Call System Submittal Package as of 3/15/2016 www.tektone.com Phone: (828) 524-9967 Toll-Free: (800) 327-8466 Sales: Option 2 Tech Support: Option 3 277 Industrial Park Road Franklin, NC 28734 [email protected] Fax: (828) 524-9968 Copyright © 2016 TekTone® Sound & Signal Mfg., Inc., All rights reserved. No part of these publications may be copied without the express written permission of TekTone® Sound & Signal Mfg., Inc. The contents of these specification sheets are furnished for informational use only, are subject to change without notice, and should not be construed as a commitment by TekTone® Sound & Signal Mfg., Inc. TekTone® Sound & Signal Mfg., Inc. assumes no responsibility or liability for any errors or inaccuracies that may appear in this documentation. TekTone, the TekTone logo, Tek-Alert, Tek-Bridge, Tek-Call, Tek-Care, TekCD, Tek-Check-In, Tek-Com, Tek-Entry, Tek-Guard, Tek-Micro, Tek-MMARS, Tek-Paging, Tek-Safe and Tek-Status are either registered trademarks or trademarks of TekTone® Sound & Signal Mfg., Inc. in the United States and/or other countries. All other trademarks are the property of their respective owners. NC305LCD Master Station IL693 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 8 - 07/2013 Features • • • • • • • • • • • • • • • • • • • • • • • • • • UL® 1069 Listed Supervised Serial & Keyboard ports Spill-proof membrane switch with alphabetic characters Easy access to commonly used menu functions Simultaneous display of 20 calls Clear, distinct voice communications Simple, menu-driven programmable functions Master-to-master intercom capability Push-to-Talk button or handset intercom Calls displayed by priority and origination Calls identified by room and bed number Programmable patient priority and privacy Calls-waiting, calls-overtime and cord-out indication View station configuration capability Initiate stat staff emergency request Upgrade patient call Distinct tones for high, medium and low-priority calls Nurse follower function Paging by zone or to all staff Patient monitor single or group Manual tone-silencing switch (for Routine calls only) High priority calls override tone-off feature Simplified multiplex wiring uses plug-in type connectors Continuous display of nurse/aide location and nurse/ aide requested Use masters in parallel or independently Description A major component of the Tek-CARE®NC300II System, the NC305LCD master station supplies the user interface to respond to calls, issue staff requests and alter room programming status to accommodate differing patient needs. The master console allows for room and staff communication by either open speaker or handset for additional privacy. It includes an integrated backlit color LCD VGA display with NC305LCD Master Station 10.4" viewing area to display up to 20 active patient, staff or duty calls, plus columns for two levels of staff presence and STAT priority calls in English language format. Master function buttons are provided to select the system functions as follows: reset aide nurse stat menu page follow talk alpha (black) Terminates most operations. (yellow) Enters an aide service request. (green) Enters a nurse service request. (red) Enters an urgent staff emergency request. (gray) Initiates paging operations. (blue) Displays functions menu for programming additional features. (orange) Initiates nurse-follower operations. (white) Press to speak, press again to listen when using loudspeaker for communications. (white) Changes all function keys to the specifically labeled alpha characters. monitor (blue) www.tektone.com Enables room monitoring. 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) capture (blue) view (blue) priority (blue) Allows for zone assignment. Allows review of station information. Activates menu for changing room priority. tone on (white) Turns normal call-tone on/off. + – > < (white) Adjusts volume up (white) Adjusts volume down (white)Space (white)Backspace Additional programmable functions include: set station priority, set privacy, zone assignments, view station configurations, set password, reset time of day, time display, set overtime, transfer for master stations, paging, system configuration, and system re-initialization. The master station is equipped with volume control for adjustment of incoming voice communication; tone on/off switch for controlling the lowest priority tone signal only; call light with indication of low, medium and high priority calls; CE fault LED; busy and alphanumeric keypad used for entry of station numbers, zone and station selection, and for selection of menu functions. The master station also provides a serial port for connection to ancillary devices. System programming is accessible to the user via the keys on the master station or via the keyboard port which accepts any standard USB keyboard. Listings UL® 1069 listed; UL® File Number E71599. Specifications Dimensions: Capacity: Console: 13.2″ × 9″ × 5.5″ (335mm × 229mm × 140mm) Address up to 512 single or dual patient stations in up to 16 zones Environments:26°C, relative humidity should not exceed 80% Terminations: Plug-on connectors System Protection: All outputs are protected by selfresetting current-limiting devices Current Requirements: 0.75A @ 16VAC Required Components Central Equipment: NC351(A)—4 masters/256 stations –or– NC351(A)/2—8 masters/512 stations IR300C-series Patient Stations NC351A and NC351A/2 Central Equipment IL696 Specification Sheet Tek-CARE® NC300II Nurse Call System • Rev. 10 - 04/2013 Features • • • • • • UL® 1069 Listed Supports 4 masters and 256 stations (NC351A) or 8 masters and 512 stations (NC351A/2) Plug-in connections with multiplexed common wiring Self-contained electronics and power supply Serial port for Tek-PAGING® radio pocket paging system Serial port for Tek-MMARS ® 300 management monitoring and reporting system NC351A and NC351A/2 Central Equipment Description A major component of the Tek-CARE® NC300II Nurse Call System, the NC351A and NC351A/2 central equipment supply the central point for system component integration. The NC351A supports up to 4 master consoles and 256 patient/staff stations, while the NC351A/2 supports up to 8 master consoles and 512 patient/staff stations. The NC351A and NC351A/2 house the necessary firmware and control circuits to operate all the Tek-CARE® NC300II system functions. From a single durable metal enclosure, the central equipment supports 2 isolated serial ports, field station ports, master console ports, and power requirements for up to 256 patient, staff and duty stations (512 with external PK305A Supply). Listings UL® 1069 listed; UL® File Number E71599. Specifications Dimensions: Capacity: 15.25″ × 13″ × 6.25″ (387 mm × 330 mm × 159 mm) up to 4 (NC351A) or 8 (NC351A/2) masters, up to 256 (NC351A) or 512 (NC351/2A) stations Power Input: 115 VAC, 60Hz, 140W Environments: 26°C, relative humidity maximum 80% Terminations: Plug-on connectors System Supervision: Continuous polling of all stations. Stations or wiring faults displayed at masters. System All outputs are protected by self-resetting Protection: current-limiting devices. Audio: Up to 4 (NC351A) or 8 (NC351A/2) audio paths provided. Amplifiers rated at 20 watts. Overload and short circuit protection included. Required Components Tek-CARE®NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) PK305A Supplemental Power Supply IL698 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 6 - 07/2013 Features • • • Plug-in connectors for easy connection to NC351A/2 Central Equipment Provides additional power to the NC351A/2 Central Equipment to support 512 patient stations UL® 1069 Listed Description The PK305A Supplemental Power Supply is used to provide additional power to the NC351A/2 Central Equipment to support 512 patient stations. The supplemental power supply is housed in a durable metal enclosure with provisions for plug-in field wiring connections. Listings UL® 1069 listed; UL® File Number E71599. PK305A Supplemental Power Supply Specifications Dimensions: Console: 10.75″ × 8.75″ × 3.25″ 115 VAC, 60Hz, 140W Power Input: Environments:26°C, maximum 80% relative humidity Plug-in connectors Terminations: System Protection: In-line fuses are provided on primary input Required Components Tek-CARE®NC300II Nurse Call System with NC351A/2 Central Equipment www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) NC385 Tek-BRIDGE® with Tek-MMARS®300 Management Monitoring and Reporting System IL504 Specification Sheet Tek-CARE® NC300/II Nurse Call Systems • Rev. 18 - 03/2016 Features • • • • • • • Proprietary server with built-in speaker, flat panel monitor, keyboard and mouse. Includes reporting, event monitor, and one remote event monitor. Includes paging software module for automatic and manual pages to staff. Includes software module to connect one Tek-CARE® NC300/II nurse call system. Additional licenses are available separately. Optional software modules include up to eight additional remote event monitors, Tek-CARE®400 and Tek-CARE®500ES connections, and email output. 3 network interface cards/ports provide connections to a LAN and a Tek-CARE®400 central equipment. 6 RS232 serial ports provide connections for a paging transmitter, plus up to 4 directly connected Tek-CARE® NC300/II nurse call systems. Description NC385 Tek-BRIDGE® with Tek-MMARS®300 • The NC385 Tek-BRIDGE® with Tek-MMARS®300 software is the management monitoring and reporting system for the Tek-CARE® NC300/II nurse call system. The Tek-BRIDGE® server also supplies ports for a local area network (LAN) or the facility’s LAN, and the radio pocket paging system’s paging transmitter. Each Tek-CARE® NC300/II nurse call system connects either to one of the server’s unused serial ports, or to the LAN using a CT601 Serial to IP Converter. • The Tek-MMARS®300 software includes these modules: • • LS301 Tek-CARE® NC300/II Connection enables Tek-MMARS®300 to monitor one nurse call system. Purchase an LS302 license for each additional Tek-CARE® NC300/II system to be monitored. LS576 Event Monitor displays all activity of monitored Tek-CARE® NC300/II systems on the Tek-BRIDGE®. • LS586 Remote Event Monitors display Tek-CARE® NC300/II nurse call system activity. This software may be installed on up to nine of the facility’s personal computers (PCs) running Microsoft® Windows®, and networked to the Tek-BRIDGE® server. One license is included with the NC385. Purchase additional licenses separately as one license (LSMON1) or a block of five licenses (LSMON5). Tek-CARE® Reporting System records all nurse call activity on the Tek-BRIDGE®, and provides custom reports on this activity for followup review and evaluation by management. Reports are viewed using a web browser (such as Microsoft® Internet Explorer). They may also be printed, saved as HTML files for later viewing in a web browser, or saved as CSV files for viewing in a spreadsheet program (such as Microsoft® Excel). When connected to a facility’s LAN, the Tek-CARE® Reporting System can be accessed by any networked computer via a web browser. LS450 Config Tool is used to set up and customize the Tek-MMARS®300 software, and to save the system configuration. www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by DQS to the ISO 9001 standard. (Reference #10001510.) Optional Software Required Components Available separately, these optional software modules run on the Tek-BRIDGE® server, adding ancillary features to the Tek-CARE® NC300/II nurse call system. Tek-CARE®NC300II nurse call system –or– Tek-CARE®NC300 with Tek-NIOS software version 1.96, 3.06 or 4.06. (Earlier versions and “S” versions of the Tek-NIOS software are not compatible. To determine a system’s software version, push the menu button on the nurse master station.The menu version is displayed at the top of the Menu box, for example: TEK-NIOS 1.96.) • • • • • LS453 Email Output enables email addresses to be added as staff devices. The software sends calls and other events via email to the assigned staff members. Events can also be sent to anything that has an email gateway—for example, sending an SMS message to a cellphone. The LS453 Email Output software also enables the Tek-CARE® Reporting System to automatically send reports via email. LS400 Tek-CARE®400 Connection Software enables the Tek-BRIDGE® to monitor Tek-CARE®400 nurse call system activity. LS501ES Tek-CARE®500 allows the Tek-BRIDGE® to act as the master station for our wireless emergency call system. It also enables use of the NC502 PC-Alarm Panel to auto dial a central monitoring facility. LS601 Tek-ALERT® Integration Manager imports events from other systems (such as nurse call and fire alarm) and displays them on Tek-CARE® NC300/II event monitors. LS701K Tek-CARE®700 Software plus Starter Kit enables the Tek-BRIDGE® to display and store events from the wander management system. Optional Components Software: • LS302 One Tek-CARE® NC300/II Connection License • LS453 Email Output Software • LSMON1 One Remote Event Monitor License • LSMON5 Five Remote Event Monitor Licenses • LS400 Tek-CARE®400 Nurse Call System Connection (requires Tek-CARE®400 hardware) • LS501ES Tek-CARE®500 EchoStream Connection Software (requires Tek-CARE®500 hardware) • LS601 One Tek-ALERT ® Foreign Device License (requires Tek-ALERT® hardware) • LS701K Tek-CARE®700 Software plus Starter Kit (requires Tek-CARE®700 hardware) Hardware: • CT601 Serial to IP Converter Tek-PAGING® UHF Pocket Paging System: • NC365B Paging Transmitter • NC397A Alphanumeric Pagers NOTE: The Tek-BRIDGE® with Tek-MMARS®300 software is ancillary to the nurse call system and must not be used as the primary means of annunciation for the Tek-CARE®NC300/II nurse call system. To respond to calls, staff must have access to features that are available only on the nurse call system’s master stations. CT601 Serial to IP Converter IL918 Specification Sheet Tek-ALERT™ Alert Integration Manager, Tek-MMARS®300 System • Rev. 2 - 07/2013 Description The CT601 Serial to IP Converter is used to connect a TekCARE® NC300/II nurse call system or a monitored foreign system to a facility’s LAN. Events and messages from the connected system are sent across the LAN to either an NC385 Tek-MMARS®300 or a Tek-BRIDGE™ running TekALERT™ Software. The CT601 Serial to IP Converter becomes a virtual COM port on the Tek-MMARS®300 or Tek-BRIDGE™, and provides long distance communication between it and the monitored serial device. The CT601 eliminates the otherwise expensive long-distance cabling required for these connections. Configuring the CT601 is accomplished using software provided with the device. The unit can be wall or DIN-rail mounted. The CT601 incorporates surge protection. Specifications Serial Port: Male DB9 serial port, 1200 bps to 115 Kbps, hardware flow control RS232 Signals: Rx, Tx, RTS, CTS, DTR, DSR, GND, DCD Network Port: 10Base-T Ethernet Protocols: ARP, IP/ICMP, TCP/IP, Telnet, DHCP client, DNS Security: User ID & Password, IP Address filtering Power: 7.5 ~ 15VDC, 300mA 7.5V Environment: 90% non-condensing humidity; 0˚C ~ 50˚C operating temperature. Dimensions:3.9″×2.8″×1.0″ (100mm×72mm×25mm) Certification: FCC (A), CE, MIC CT601 Serial to IP Converter Required Components One of the following: • NC385 Tek-MMARS®300 Management Monitoring and Reporting System • NC470 Tek-BRIDGE™ with Tek-CARE®400 Software • NC501ES Tek-BRIDGE™ with Tek-CARE®500 Software • NC601 Tek-BRIDGE™ with Tek-ALERT™ Software Plus one for each monitored system: • LS302 Tek-CARE® NC300/II Connection License –or– • LS601 Tek-ALERT™ Software License www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) PK250B Power/Standby UPS IL472 Specification Sheet Tek-CARE® and Tek-ALERT® Systems • Rev. 17 - 05/2014 Description The PK250B Uninterruptable Power Supply provides uninterrupted power in the event of utility power failures, brownouts and blackouts. It is for use with the Tek-CARE® NC300II Nurse Call System and the Tek-BRIDGE® Server. Its economical cost and compact size will enhance the operation of your system. When power is interrupted, the PK250B immediately cuts in to provide square wave power for the Tek-CARE® NC300II Central Equipment or the Tek-BRIDGE® until an emergency generator is activated or power is restored. In the event of a prolonged power outage, the PK250B will provide power to the limit of its battery. The green indicator on the front panel indicates power line output when steady, and battery output when flashing. The unit also provides an audible tone during battery output operation. Other features include output receptacles for connection of equipment, and power cord for standard 120 volt, 15 amp power circuit. PK250B Power/Standby UPS Specifications Listings Output Rating Wattage: Voltage: Frequency: Waveform: UL® 1778 Listed and cUL® Listed to CSA C22.1. Input Voltage: Frequency: 300 W 115 VAC 60 Hz Stepped square wave 115 VAC 60 Hz Backup Operation At full load: 2 minutes At half load: 9 minutes Transfer time: 6 ms typical Battery Type: Recharge: Auto cut-off: Size Overall: Weight Required Components Tek-CARE®NC300II Nurse Call System –or– Tek-BRIDGE® Server Maintenance-free 12V 5Ah 8 hours Yes 10.9″ × 3.5″ × 10.8″ 13.5 lbs. (6 kg) Operating temperature range is 0°C–40°C. www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) IR300E Multipurpose Station IL491 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 10 - 07/2013 Features • • • • • • UL® 1069 Listed Supervised Microprocessor design Solid-state multiplex circuitry Simplified multiplex wiring using plug-in connectors Flame-retardant (UL® 94V-0) plastic faceplate Description The IR300E Multipurpose Station provides for audible, visual and digital communications to and from the Tek-CARE®NC300II central equipment (CE) when receiving or sending signals to remotely connected devices. The IR300E includes inputs for contact closures and all types of emergency call switches for these systems. It also provides outputs to speakers or paging amplifiers, and dome or zone lamps. It does not have the controls, LEDs, or speakers normally associated with patient, staff or duty stations. Some practical applications for the IR300E are as follows: provides input for code emergency call stations in an ICU; a PA amplifier interface for the nurse call master; a control point for exit/entry doors and narcotics cabinets; provides input for bath emergency call switches in public bath areas; provides input/output to a remote door intercom station for access control. Listings UL 1069 listed; UL File Number E71599. ® ® IR300E Multipurpose Station Specifications Dimensions: Construction: Connections: Housing: Wiring: Height: 4.5″ (114 mm) Width: 6.375″ (162 mm) Depth: 2.75″ (70 mm) Projects: 0.375″ (9.5 mm) Flame retardant (UL® 94V-0) plastic Plug-in type Steel City #H3BD with Steel City #3GC plaster ring, or exact equal. Horizontal mount. Multiplex. Required Components Tek-CARE®NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) IR310E Staff Station IL493 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 11 - 07/2013 Features • • • • • • • • • UL® 1069 Listed Supervised Microprocessor design Solid-state multiplex circuitry Field programmable for staff or patient station operation Programmable call priority All stations interchangeable Simplified multiplex wiring using plug-in type connectors Attractive flame retardant (UL® 94V-0) plastic panel IR310E Staff Station Description The IR310E Staff Station provides reliable two-way, hands-free communication between the nurse master station and utility room, examination rooms, kitchen, or any location where staff members may need to originate calls or where cord sets are not required. Calls are placed by use of a momentary push button. Solid-state lights on the panel indicate that the call has been placed and that the intercom is in use. As an additional feature, the staff station is field programmable to function as a patient station, if desired. Listings UL® 1069 listed; UL® File Number E71599. Specifications Dimensions: Construction: Finish: Speaker: Connections: Housing: Height: 4.5″ (114 mm) Width: 6.375″ (162 mm) Depth: 2.75″ ( 70 mm) Projects: 0.5″ (12.7 mm) Flame retardant (UL® 94V‑0) plastic Light texture, white 2.5″ × 2.5″ (64 mm × 64 mm) Plug-in type Steel City #H3BD with Steel City #3GC plaster ring or exact equal. Horizontal mount. Required Components Tek-CARE®NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) IR315F Duty Station IL495 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 12 - 07/2013 Features • • • • • • UL® 1069 Listed Supervised All stations interchangeable Simplified multiplex wiring using plug-in connectors Attractive, flame retardant (UL® 94V-0) plastic faceplate Selective annunciation of call priority Description The IR315F Duty Station provides reliable two-way, handsfree communication between the nurse master station and utility rooms, examination rooms, kitchen, or any location where a nurse may perform a function out of hearing or sight of the master station. Calls are placed to the master station by use of a momentary push button. When the call is answered at the master station, the red in-use indicator on the duty station lights, and the nurse may then carry on a conversation from the remote location. A call originating from a patient station is indicated both audibly and visually at the duty station to which it is assigned. Normal calls are indicated by a steady illumination of the yellow call-placed indicator and a slow repeating tone. Emergency/bath calls cause alternate flashing of the yellow call-placed and red emergency indicators and a rapid repeating tone. Code calls function the same as emergency calls, but at twice the pulse rate. Dome light indication is also provided. All calls initiated from stations other than the duty station can be reset only at the master station or point of origin. Listings UL 1069 listed; UL File Number E71599. ® ® IR315F Duty Station Specifications Dimensions: Construction: Speaker: Connections: Housing: Height: 4.5″ (114 mm) Width: 6.375″ (162 mm) Depth: 2.75″ (70 mm) Projects: 0.5″ (12.7 mm) Flame retardant (UL® 94V-0) plastic 2.5″ × 2.5″ (64 mm × 64 mm), 60 ohm Plug-in type Steel City #H3BD with Steel City #3GC plaster ring, or exact equal. Horizontal mount. Required Components Tek-CARE®NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) IR318B Single Patient Station IL689 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 9 - 07/2013 Features • • • • • • • • UL® 1069 Listed Supervised Microprocessor design Solid-state multiplex circuitry All stations are interchangeable Simplified multiplex wiring using plug-in connectors Flame-retardant (UL® 94V-0) plastic faceplate Six-foot washable TPU plastic pull cord Description The IR318B single patient station provides reliable twoway hands-free communication between patient and nurse, and provides for programmable privacy, paging and patient priority from the master station. Calling the nurse is accomplished by pulling on the end of the pull cord. Solid-state LEDs on the panel indicate the call has been placed and the intercom is in use. Listings UL® 1069 listed; UL® File Number E71599. IR318B Single Patient Station Specifications Dimensions:Height: 4.5″ (119 mm) Width: 6.375″ (162 mm) Depth:2.75″ (70 mm) Projects: 0.5″ (12.7 mm) Construction: Flame-retardant (UL® 94V-0) plastic. Speaker:2.5″ × 2.5″ (64 mm × 64 mm) Connections: Plug-in type Housing: Steel City #H3BD with Steel City #3GC plaster ring, or exact equal. Horizontal mount. Wiring:Multiplex Required Components Tek-CARE®NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) IR319B Single and IR320B Dual Patient Stations IL713 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 4 - 07/2013 Features • • • • • • UL® 1069 Listed Supervised All stations interchangeable Simplified multiplex wiring and plug-in connectors Input available for Hill-Rom® Sidecom® beds or remote call-in button applications Uses pillow speakers or push-button call cords Description The IR319B Single Patient Station provides reliable twoway, hands-free communication between patient and nurse, and provides for programmable privacy, paging and patient priority from the master station. Calling the nurse is accomplished by pressing the call cord button or the area indicated nurse on the pillow speaker. Solid state LEDs on the panel indicate the call has been placed and the intercom is in use. If the pillow speaker or call cord is accidentally removed from its receptacle, the nurse master station registers a non-cancellable cord out call. The call may be reset only by returning the call cord or pillow speaker to its receptacle. The IR320B Dual Patient Station has the same specifications and functions as the IR319B, plus an additional independently operating call cord/pillow speaker receptacle and a second call-placed indicator. Listings UL® 1069 listed; UL® File Number E71599. IR319B Single and IR320B Dual Patient Stations Specifications Dimensions: Height: 4.5″ (114 mm) Width: 6.375″ (162 mm) Depth: 2.75″ (70 mm) Projects: 1.0″ (25 mm) above mounting surface Construction: Flame-retardant (UL® 94V-0) plastic faceplate 2.5″ × 2.5″ (64 mm × 64 mm) Speaker: Connections: Plug-in type Housing: Steel City #H3BD and #3GC plaster ring, or exact equal. Horizontal mount. Required Components Tek-CARE®NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF401A Oxygen-Safe Call Cord IL767 Specification Sheet Tek-CARE®400 P5 Nurse Call System • Rev. 5 - 11/2012 Features • • • • • UL® 1069 Listed Oxygen safe Impact resistant and waterproof Small, lightweight pendant fits comfortably in hand Bed clips included Description The TekTone® SF401A single call cord is for use with the Tek-CARE ® 400, Tek-CARE ® 400 P5, and TekCARE®NC300II nurse call systems, where 8-pin DIN jacks are used. The SF401A is an oxygen safe call cord that is certified safe for use by all patients receiving oxygen therapy. This waterproof and impact resistant call cord has a completely sealed push button. Listings UL® 1069 listed; UL® File Number E71599. Specifications Connection: Construction: Dimensions: SF401A Oxygen-Safe Call Cord Required Components for the Tek-CARE®400 nurse call system: IR411, IR411EPB, IR412, IR412EPB patient stations for the Tek-CARE®400 P5 nurse call system: IR411P5, IR412P5 patient stations for the Tek-CARE®NC300II nurse call system: IR319B, IR320B patient stations 8-pin DIN plug SPST1-A switch Integral brass, fine silver contacts 1 AMP, 115 watt maximum, AC 7' (2.13 m) long polyvinyl-covered cord www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF401G Call Cord IL829 Specification Sheet Tek-CARE® Nurse Call Systems • Rev. 3 - 11/2014 Features • • • • • Sensitive touch activation Oxygen tent safe Ideal for geriatric use Momentary, air-activated switch Adjustable bed clip Description TekTone® SF401G Call Cords are used with 8-pin DIN jack patient stations, including Tek-CARE®400 IR411- and IR412-series patient stations, Tek-CARE®400 P5 IR411P5 and IR412P5 patient stations, and Tek-CARE® NC300II IR319- and IR320-series patient stations. The SF401G Call Cord is specifically designed for use in geriatric and oxygen environments, but may also be used in general applications. To place a call, the patient need only apply slight pressure to the squeeze bulb using any part of the body. The force of air through the vinyl tubing closes a switch in the plug, thus placing a call. An adjustable bed clip is supplied for the SF401G and is attached to the call cord. Specifications Switch: Plug: Cord: Electrical: Dimensions: Momentary contact, air activated Stainless steel 8-pin DIN Vinyl tubing Rated current 1/3 amp, 24 VAC-VDC Cord:6′ long (1.83 m) Bulb: 1.5" diameter (38 mm) SF401G Call Cord Required Components for Tek-CARE®NC300II Nurse Call Systems: IR319- or IR320-series Patient Stations for Tek-CARE®400 Nurse Call Systems: IR411- or IR412-series Patient Stations for Tek-CARE®400 P5 Nurse Call Systems: IR411P5 or IR412P5 Patient Stations www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF401GP Geriatric Pad Call Cord IL989 Specification Sheet Tek-CARE® Nurse Call Systems • Rev. 0 - 10/2015 Features • • • • • Non-powered pneumatically operated switch Large 3.5″ diameter pad for easy activation Oxygen safe Latex free Includes security clip Description The SF401GP Geriatric Call Cord is a round, flattened soft vinyl pad with gripping feet to prevent it from slipping off the patient’s bed. The SF401GP works well for residents who have limited hand dexterity. It has a mechanical switch that is activated by slight pressure from the hand, arm or body, or can even be positioned under the resident’s chin. The SF401GP has an 8-foot cord and an 8-pin DIN plug. Also available is the SF401GP/10 with a 10-foot cord. Listings SF401GP Geriatric Pad Call Cord UL® 1069 Listed and cUL® Listed to CSA C22.2 No. 205; UL® File Number E61802. Specifications Cord Length: 8′ (2.44 meters) Connections: 8-pin DIN plug Switch: Momentary contact Electrical Rating:24 volts AC or DC at 0.33 amps Required Components for Tek-CARE®NC300II Nurse Call Systems: IR319B or IR320B Patient Station SF401EX Strain Relief Cable for Tek-CARE®400 Nurse Call Systems: IR411-series or IR412-series Patient Station SF401EX Strain Relief Cable www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF401EX Strain Relief Cable IL886 Specification Sheet Tek-CARE®400 P5 Nurse Call System • Rev. 2 - 11/2012 Features • • • • UL® 1069 Listed Molded connectors Clean break-away action Increases life of call cords, pillow speakers and room stations Description The SF401EX Strain Relief Cable is used to increase the life span of call cords, pillow speakers and room stations. The 8-pin DIN cable is placed between the call cord or pillow speaker and the room station. If the call cord or pillow speaker is attached to a bed and then the bed is pulled away, the strain relief cable disconnects. This prevents damage to both the room station and the call cord or pillow speaker. Listings UL® 1069 listed; UL® File Number E71599. SF401EX Strain Relief Cable Specifications Required Components Length: Connections: Construction: for Tek-CARE®NC300II Nurse Call Systems: IR319- or IR320-series Patient Stations SF4-series Call Cords or Pillow Speakers 6" (153 mm) 8-pin DIN plugs 24-gauge polyvinyl-covered cord with molded ends for Tek-CARE®400 Nurse Call Systems: IR411- or IR412-series Patient Stations SF4-series Call Cords or Pillow Speakers for Tek-CARE®400 P5 Nurse Call Systems: IR411P5 or IR412P5 Patient Stations SF4-series Call Cords or Pillow Speakers www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF41-series Pillow Speakers IL824 Specification Sheet Tek-CARE®400 P5 Nurse Call System • Rev. 7 - 11/2012 Features • • • • • • • • SF41ZKL (standard) for Zenith Digital TVs, includes direct channel access, digital volume controls and 2 light controls UL® 1069 Listed Oxygen safe Fully sealed for easy cleaning Flame-retardant (UL® 94V-0) high-impact plastic Long lasting switches surpass UL®1069 requirements 8-foot cord with DIN plug and security clip Provides pillow speaker intercom and light control (when used with the appropriate modules) Special Order: RCA or Philips TV controls, analog volume control, 10-foot cord, earphone jack Description SF41-series Pillow Speakers are used with Tek-CARE®400 IR411- and IR412-series patient stations, Tek-CARE®400 P5 IR411P5 and IR412P5 patient stations, and Tek-CARE® NC300II IR319- and IR320-series patient stations. The pillow speakers provide call placement to the master station, as well as remote control for hospital-grade digital TVs (Zenith is standard; RCA and Philips are available by special order). When used in conjunction with the appropriate TekTone® pillow speaker modules, the pillow speakers also supply two-way, hands-free communication with the master station, and automatic silencing of TV audio while the intercom is in use. Push buttons are provided to call the nurse, plus TV power, channel selection up/down, Closed Captioning, mute and two light controls. Buttons are also provided for volume up/down (analog volume controls are available by special order), and for direct channel access (in some models). Listings UL® 1069 listed; UL® File Number E165723. SF41ZDL (standard) fo r Z e n i t h D i g i t a l T Vs , includes channel up/down, digital volume controls and 2 light controls SF41-series Pillow Speakers Required Components Hospital-grade Zenith Digital TV for Tek-CARE®NC300II Nurse Call Systems: IR319- or IR320-series Patient Station PM311C or PM312C Pillow Speaker Intercom Module PM321B or PM322B Light Control Module for Tek-CARE®400 Nurse Call Systems: IR411- or IR412-series Patient Station PM421 or PM422 Pillow Speaker & Bed Interface Module for Tek-CARE®400 P5 Nurse Call Systems: IR411P5 or IR412P5 Patient Station PM421P5 or PM422P5 Pillow Speaker Module www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) PM311C, PM312C Pillow Speaker Intercom Modules IL429 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 12 - 07/2013 Features • • • UL® 1069 Listed (when used with IR319B, IR320B, IR311E or IR312E patient stations) Provides hands-free pillow speaker intercom Mounts directly to patient stations Description The PM311C and PM312C Pillow Speaker Intercom Modules are for use with the Tek-CARE®NC300II Nurse Call System using IR319B, IR320B, IR311E or IR312E patient stations and SF41ZDL, SF41ZKL, SF31ZDL or SF31ZKL pillow speakers. The modules provide for reliable, two-way handsfree communication from the pillow speaker to the master station. Calling the nurse is accomplished by pressing the push button identified with the nurse symbol. Call placed assurance is indicated at the patient station. If the pillow speaker is removed from its receptacle during communication, the call is automatically transferred to the patient station speaker. If the pillow speaker or call cord is removed from its receptacle when not in use, a non-cancellable cord-out call is registered at the master station. Standard SF401-series or SF311-series call cords may be used without removing modules. Communication is automatically transferred to the patient station speaker. Listings UL® 1069 listed; UL® File Number E71599. PM312C Pillow Speaker Intercom Module Specifications Dimensions:Width: 5″ (127 mm) Depth:1.875″ (47.6 mm) Height:0.5″ (12.7 mm) Construction: PC board with quality electronic components Mounting: Plug-in connectors mounted to patient station Wiring:Multiplex Required Components Tek-CARE®NC300II Nurse Call System IR319B or IR320B Patient Stations with SF41ZDL or SF41ZKL Pillow Speakers –or– IR311E or IR312E Patient Stations with SF31ZDL or SF31ZKL Pillow Speakers www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) PM321B, PM322B Multiplex Lamp Control Modules IL461 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 11 - 07/2013 Features • • • UL® 1069 Listed (when used with IR319B, IR320B, IR311E or IR312E patient stations) Provides on/off control of two lamp sources Mounts directly to patient station or to pillow speaker intercom module (if used). Description The PM321B and PM322B Multiplex Lamp Control Modules are for use with the Tek-CARE®NC300II Nurse Call System using IR319B, IR320B, IR311E or IR312E patient stations and SF41ZDL, SF41ZKL, SF31ZDL or SF31ZKL pillow speakers. The modules provide on/off control through the pillow speaker of two lamp sources, typically the overhead room lamp and a separate reading lamp. Circuitry for low voltage lamp switching is provided by others. Turning the lamps on or off is accomplished by pressing the appropriate push buttons on the pillow speaker. The lamp control module can be mounted directly to the patient station, or can be mounted to the station’s PM311C or PM312C pillow speaker intercom module. Standard SF401-series or SF311-series call cords may be used without removing modules. Listings UL® 1069 listed; UL® File Number E71599. Specifications PM322B Multiplex Lamp Control Module Required Components Tek-CARE®NC300II Nurse Call System IR319B or IR320B Patient Stations with SF41ZDL or SF41ZKL Pillow Speakers –or– IR311E or IR312E Patient Stations with SF31ZDL or SF31ZKL Pillow Speakers Dimensions:Width: 5″ (127 mm) Depth:1.625″ (41 mm) Height:0.5″ (13 mm) Construction: PC board with quality electronic components Mounting: Plug-in connectors mounted to patient station or to PM311C/PM312C (if used) Wiring:Multiplex www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) IR311E Single & IR312E Dual Patient Stations IL494 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 9 - 07/2013 Features • • • • • • UL® 1069 Listed Fully supervised All stations interchangeable Simplified multiplex wiring & plug-in type connectors Input available for Hill-Rom® Sidecom® beds or remote call-in button applications Uses pillow speakers or push button call cords Description The IR311E Single Patient Station provides reliable twoway, hands-free communication between patient and nurse, and provides for programmable privacy, paging, and patient priority from the master station. Calling the nurse is accomplished by pressing the call cord button or the area indicated nurse on the pillow speaker. Solid-state LEDs on the panel indicate the call has been placed and the intercom is in use. If the pillow speaker or call cord is accidentally removed from its receptacle, the nurse master station registers a non-cancelable call with cord out indication. The call may be reset only by returning the call cord or pillow speaker to its receptacle. The pillow speaker also provides television control. The IR312E Dual Patient Station has the same specifications and functions as the IR311E, and has an additional independently operating call cord/pillow speaker receptacle, and another call-placed indicator. Listings UL® 1069 listed; UL® File Number E71599. IR312E Dual Patient Station Specifications Dimensions: Height: 4.5″ (114 mm) Width: 6.375″ (162 mm) Depth: 2.75″ (70 mm) Projects: 0.5″ (12.7 mm) above mounting surface Construction: Flame-retardant (UL® 94V-0) plastic faceplate Speaker: 2.5″ × 2.5″ (64 mm × 64 mm) Connections: Plug-in type Steel City #H3BD and #3GC plaster ring, Housing: or exact equal. Horizontal mount. Required Components Tek-CARE®NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF31ZDL, SF31ZKL Pillow Speakers IL930 Specification Sheet Tek-CARE® NC300II Nurse Call Systems • Rev. 1 - 04/2013 Features • • • • • • • • UL® 1069 Listed Oxygen safe Fully sealed for easy cleaning Flame-retardant (UL® 94V-0) high-impact plastic Long lasting switches surpass UL®1069 requirements 8-foot cord with 8-pin 8P8C plug and security clip Provides pillow speaker intercom and light control (when used with the appropriate modules) Special Order: RCA or Philips TV controls, analog volume control, 10-foot cord, earphone jack SF31ZKL for Zenith Digital TVs, includes direct channel access, digital volume controls and 2 light controls Description The SF31ZDL and SF31ZKL Pillow Speakers are used with Tek-CARE® NC300II IR311-series and IR312-series patient stations. The pillow speakers provide call placement to the master station, as well as remote control for hospital-grade digital TVs (Zenith is standard; RCA and Philips are available by special order). When used in conjunction with the appropriate TekTone® pillow speaker modules, the pillow speakers also supply two-way, hands-free communication with the master station, and automatic silencing of TV audio while the intercom is in use. Push buttons are provided to call the nurse, plus TV power, channel selection up/down, Closed Captioning, mute and two light controls. Buttons are also provided for volume up/down (analog volume controls are available by special order), and for direct channel access (in some models). SF31ZDL for Zenith Digital TVs, includes channel up/down, digital volume controls and 2 light controls SF31ZDL, SF31ZKL Pillow Speakers Required Components Hospital-grade Zenith Digital TV IR311- or IR312-series Patient Station PM311C or PM312C Pillow Speaker Intercom Module PM321B or PM322B Light Control Module Listings UL® 1069 listed; UL® File Number E71599. www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) LI380 Corridor Dome Light IL519 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 9 - 07/2013 Features • • • • • UL® 1069 Listed Easy bulb replacement Snap-in colored lens sections Excellent visibility Interchangeable lenses Description TekTone®’s LI380 Corridor Dome Light provides visual indication of calls originating from patient, staff, duty, bath, emergency, presence and code call stations. Patient priority and staff presence are indicated by amber, green, red and white colored lenses. When used with any room station or IR310E Staff Station, the LI380 indicates all calls originated from that room. When used with the IR300E Multipurpose Station or the IR315F Duty Station, the LI380 may be used as a zone light to indicate all calls from the zones to which those stations are assigned. Listings UL® 1069 listed; UL® File Number E71599. LI380 Corridor Dome Light Required Components Tek-CARE®NC300II Nurse Call System Specifications Dimensions:Height: 4.5625″ (115 mm) Width:4.5625″ (115 mm) Depth:3.3″ (84 mm) Bulbs: #1829 28v. 70mA Power: 24 VDC, 205 mA Finish: Base is flame-retardant (UL® 94V-0) plastic. Amber, green and red lenses are flame-retardant translucent polycarbonate plastic. White lens is flame-retardant translucent polystyrene plastic. Housing: Fits standard dual gang box with either single gang ring or dual gang ring. www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) LI380LED Corridor Dome Light IL913 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 2 - 07/2013 Features • • • • • UL® 1069 Listed Long lasting LEDs No bulb replacement required Plug-in connector supplied Attractive flame-retardant plastic panel Description TekTone®’s LI380LED Corridor Dome Light provides visual indication of calls originating from patient, staff, duty, bath, emergency, presence and code call stations. Patient call priority and staff presence are indicated by amber, green, red and white colored LEDs. When used with any room station or IR310E Staff Station, the LI380LED indicates all calls originated from that room. When used with the IR300E Multipurpose Station or the IR315F Duty Station, the LI380LED may be used as a zone light to indicate all calls from the zones to which those stations are assigned. Listings UL® 1069 listed; UL® File Number E71599. LI380LED Corridor Dome Light Specifications Dimensions:Height: 4.8″ (122 mm) Width:5.0″ (127 mm) Depth:2.755″ ( 70 mm) LEDs: 2V 20mA per LED Power: 24 VDC Finish: Base is flame-retardant (UL ® 94HB) plastic. Lens is flame-retardant translucent polycarbonate plastic. Housing: Fits standard one- or two-gang box with one- or two-gang ring. Required Components Tek-CARE®NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) LI381 Corridor Light & LI382 Corridor Zone Light IL518 Specification Sheet Tek-CARE® Nurse Call & CM800 Emergency Call Systems • Rev. 18 - 07/2013 Features • • • • • UL® 1069 Listed Snap-in lens Easy bulb replacement Attractive flame-retardant HIPS30 plastic panel Excellent visibility Description The LI381 Corridor Light and LI382 Corridor Zone Light provide visual indication of calls when used with a nurse call system, emergency call system, or similar application. Emergency calls are indicated by the rapid flashing of the LI381 Corridor Light associated with the calling station. Normal calls produce a steady illumination. The LI382 Corridor Zone Light indicates an emergency call by the rapid flashing of the red-covered bulb associated with the zone or area from which an emergency call has been placed. Normal calls are indicated by a steady illumination of the white bulb. If an emergency and normal call are placed in the same zone at the same time, the red covered bulb connected to the emergency station will flash rapidly, while the white bulb associated with the normal call will maintain a steady illumination. The standard mounting plate accommodates both models and features an easily removable white flame-retardant translucent polystyrene plastic lens for bulb replacement. Listings UL® 1069 listed; UL® File Number E71599. LI381 Corridor Light & LI382 Corridor Zone Light Specifications Dimensions: Bulbs: Power: Finish: Housing: Height: 4.5625″ (115 mm) Width: 4.5625″ (115 mm) Depth: 3.3″ ( 84 mm) #1829 28V 70 mA LI381: 24 VDC, 51mA LI382: 24 VDC, 102mA White flame-retardant translucent polystyrene plastic lens mounted on a flame-retardant (UL® 94V-0) plastic panel. Fits either standard dual gang box and ring or single gang box and ring. Required Components Tek-CARE® NC110, NC150, NC200 or NC300II Nurse Call System –or– CM800 Emergency Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) LI382LED Corridor Zone Light IL898 Specification Sheet Tek-CARE® Nurse Call & CM800 Emergency Call Systems • Rev. 3 - 11/2014 Features • • • • • UL® 1069 Listed Long lasting LEDs No bulb replacement required Plug-in connector supplied Attractive flame-retardant plastic panel Description The LI382LED Corridor Zone Light provides visual indication of calls when used with a nurse call system, emergency call system, or similar application. The LI382LED Corridor Zone Light indicates an emergency call by the rapid flashing of the two red LED bulbs associated with the zone or area from which an emergency call has been placed. Normal calls are indicated by a steady illumination of the two white LEDs. If an emergency and normal call are placed in the same zone at the same time, the red LEDs connected to the emergency station will flash rapidly, while the white LEDs associated with the normal call will maintain a steady illumination. The standard mounting plate features both one- and twogang mounting options. LI382LED Corridor Zone Light Specifications Dimensions:Height: 4.8″ (122 mm) Width:5.0″ (127 mm) Depth:2.755″ ( 70 mm) LEDs: 2V 20mA per LED Power: 24 VDC Finish: Base is flame-retardant (UL ® 94HB) plastic. Lens is flame-retardant translucent polycarbonate plastic. Housing: Fits standard one- or two-gang box with one- or two-gang ring. Listings UL® 1069 listed; UL® File Number E71599. Required Components Tek-CARE® NC110, NC150, NC200 or NC300II Nurse Call System with NC110-, NC150-, or NC200-series master station –or– CM800 Emergency Call System with CM800-series speaker panel www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) LI386C Addressable Dome/Zone Light IL547 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 12 - 07/2013 Features • • • • • • • • UL® 1069 Listed Supervised Easy bulb replacement Excellent visibility Lamp supervision Interchangeable lens caps Simplified multiplex wiring Plug-in connectors Description TekTone ®’s LI386C Dome/Zone Light with built-in multipurpose station provides visual indication of calls originating from bath, emergency and code call switches when used as a dome light. The LI386C also indicates calls originating from patient, staff and duty stations when used as a zone light. The LI386C also indicates all calls from the zones to which those stations are assigned and provides communication to and from the central equipment, including the nurse master station and monitor. It is used with remotely-mounted devices such as switches, contact closures, or other signal-originating equipment. No controls are provided. Listings UL® 1069 listed; UL® File Number E71599. LI386C Addressable Dome/Zone Light Specifications Dimensions: Bulbs: Power: Connections: Finish: Housing: Height: 4.5625″ (115 mm) Width: 4.5625″ (115 mm) Depth: 3.3″ (84 mm) #1829 28v. 70mA 24 VDC, 51 mA Ramp lock plug-in type Base is flame retardant (UL® 94V-0) plastic. Amber, red and green lenses are flame-retardant translucent polycarbonate plastic. White lens is flame retardant translucent polystyrene plastic. Standard dual gang box and ring. Required Components Tek-CARE® NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) LI386LED Addressable Dome/Zone Light IL914 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 3 - 01/2015 Features • • • • • • • UL® 1069 Listed Long lasting LEDs No bulb replacement required Plug-in connector supplied Attractive flame-retardant plastic panel Addressable station with data signal supervision Simplified multiplex wiring Description TekTone®’s LI386LED Dome/Zone Light with built-in multipurpose station provides visual indication of calls originating from bath, emergency and code call switches when used as a dome light. The LI386LED indicates calls originating from patient and staff stations when used as a zone light. The LI386LED also indicates all calls from the zones to which those stations are assigned and provides communication to and from the central equipment, including the nurse master station and monitor. No controls are provided. Listings UL® 1069 listed; UL® File Number E71599. LI386LED Addressable Dome/Zone Light Required Components Specifications Dimensions:Height: 4.8″ (122 mm) Width:5.0″ (127 mm) Depth:2.755″ ( 70 mm) LEDs: 2V 20mA per LED Power: 24 VDC Finish: Base is flame-retardant (UL ® 94HB) plastic. Lens is flame-retardant translucent polycarbonate plastic. Housing: Fits standard one- or two-gang box with one-or two-gang ring. Tek-CARE® NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) RY351B Hill-Rom® SideCom® Adapter IL477 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 12 - 07/2013 Features • • • • UL® 1069 Listed Provides for the following functions from a Hill-Rom® SideCom® Unit: ◊ Call-placed indication ◊ Monitor indication ◊ Hands-free two-way communication ◊ Nurse Call Supervised Ramp lock plug-in connectors Description The RY351B SideCom® adapter is designed for use with IR311E, IR312E, IR319B and IR320B patient stations, and a Hill-Rom® SideCom® unit. When used with the above patient stations and the Hill-Rom® SideCom® unit, the RY351B adapter will provide all the necessary circuitry for a Hill-Rom® SideCom® unit to control all functions normally controlled by a pillow speaker. This includes, but is not limited to, nurse call and patient communications. Note: There is one RY351B SideCom® adapter required per SideCom® unit. Listings UL® 1069 listed; UL® File Number E71599. RY351B Hill-Rom® SideCom® Adapter Specifications Dimensions:Length: 4.25″ (108 mm) Width:2.00″ (50.8 mm) Height:1.25″ (31.8 mm) Construction: Circuit board mounted on a rugged aluminum mounting bracket. Connections: Reliable ramp lock plug-ins. Housing: Single gang ring, or single gang ring and double gang box, or exact equivalent. Required Components Tek-CARE® NC300II Nurse Call System JK401 Dummy plug for IR319B or IR320B patient stations www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF350B Presence Station IL407 Specification Sheet Tek-CARE®400 P5 & NC300II Nurse Call Systems • Rev. 11 - 11/2012 Features • • • • • UL® 1069 Listed Push button and green LED for nurse presence indication Push button and yellow LED for aide presence indication Automatic nurse follower transfer Flame retardant (UL® 94V-0) plastic faceplate Description The SF350B Presence Station provides push button registration of nurse presence (green LED indication), or aide presence (yellow LED indication) at remote locations. The nurse/aide presence indicator unit can also be used to transfer nurse follower feature from room to room as nursing staff proceeds with rounds. Depressing the nurse presence registration button automatically transfers indication of all subsequent patient calls to the remote location of the nurse, as well as to the master station. Plugin connectors provide for simple wiring. SF350B Presence Station Specifications Dimensions: Construction: Connections: Housing: Height: Width: Depth: Projects: 4.50" (114 mm) 2.75" (70 mm) 1.50" (38 mm) 0.4375" (11 mm) from mounting surface Flame retardant (UL® 94V-0) plastic faceplate. Switches and electronic components are circuit board mounted. Plug-in connectors. Single gang ring (IH357) with square box (IH358), or exact equal. Listings UL® 1069 listed; UL® File Number E71599. Applicable Systems Tek-CARE®400 P5 Nurse Call System Tek-CARE®NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF337C Emergency Shower Switch IL629 Specification Sheet Tek-CARE® Nurse Call Systems • Rev. 13 - 10/2015 Features • • • • • • • UL® 1069 Listed Waterproof if installed per manufacturer’s instructions Call-placed indicator Call cancel at point of origin Attractive, flame-retardant (UL ® 94V-0) plastic faceplate 1.1″ (28mm) wide pull-down lever Washable TPU plastic pull cord kit is included Description The SF337C Emergency Shower Switch is for any location where activation of an emergency signal is required. The design is such that it may be located anywhere in a shower, bath or tub room, regardless of environmental conditions. The combination of rubber-grommetted mounting screws, rubber mounting gasket, and completely sealed front faceplate make it waterproof (if properly installed). Electronic components are mounted on a circuit board, including an industry-proven reliable reed switch for call initiation. The activating magnet is mounted on the large pull-down lever, which is completely sealed in plastic. The indicator LED is also completely sealed. Due to the flexibility of its design, the SF337C may be used as a pull cord or as a pull down activated emergency switch. The pull cord supplied may be used for emergency call activation, or if desired, the large 1.1″ (28 mm) red pull-down lever may be used. Dome light and system annunciation vary according to the manner in which the SF337C is connected. Listings UL® 1069 listed; UL® File Number E71599. SF337C Emergency Shower Switch (cord not shown) Specifications Dimensions: Construction: Connections: Flush Housing: Height: 4.5″ (114.3 mm) Width: 2.8125″ (71.4 mm) Overall Depth: 1.75″ (44.4 mm) Projects Front: 0.71″ (18 mm) Projects Rear: 1.04″ (26.4 mm) ® Flame-retardant (UL 94V-0) plastic Plug-in type. Single-gang ring with square box; for Tek-CARE®500 use plastic single-gang box with minimum 2.875″ × 2.125″ opening. Surface Housing: TekTone® IH527 plastic back box for Tek-CARE®500. Applicable Systems Tek-CARE®400 P5 Nurse Call System Tek-CARE®NC300II Nurse Call System Tek-CARE® NC200, NC150, NC110 Nurse Call Systems Tek-CARE®500 Wireless Emergency Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF339 Emergency Switch IL744 Specification Sheet Tek-CARE® Nurse Call Systems • Rev. 6 - 10/2015 Features • • • • • • UL® 1069 Listed Simple and flexible operation Call-placed indicator Call cancel at point of origin Flame-retardant (UL® 94V-0) plastic faceplate 0.9″ diameter (23 mm) red mushroom-style button Description The SF339 Emergency Switch includes a locking mushroomstyle switch, and is for use in any location where activation of an emergency signal is required. All electronic components are mounted on a circuit board, including a reliable industryproven DPDT switch for circuit initiation. The DPDT switch and the indicator LED are completely sealed in plastic. The SF339 may be used as an emergency switch or as a staff-assist emergency call switch. The large mushroomstyle button is easily activated, so that calls may be placed using an elbow, shoulder, etc., when using the hands is inconvenient or inappropriate. Calls are cancelled by turning the mushroom-style button clockwise. Dome light indication and system annunciation vary according to the manner in which the SF339 is installed. SF339 Emergency Switch Listings UL® 1069 listed; UL® File Number E71599. Specifications Dimensions: Construction: Height: 4.5″ (114.3 mm) Width: 2.8125″ (71.4 mm) Overall Depth: 2″ (50.8 mm) Projects Front: 0.95″ (24.1 mm) Projects Rear: 1.05″ (26.7 mm) Flame-retardant (UL® 94V-0) plastic faceplate. DPDT switch and electronic components are circuit board mounted. Connections: Plug-in connectors. Flush Housing: Single-gang ring with square box; for Tek-CARE®500 use plastic single-gang box with minimum 2.875″ × 2.125″ opening. Surface Housing: TekTone® IH527 plastic back box for Tek-CARE®500. Applicable Systems Tek-CARE®400 P5 Nurse Call System Tek-CARE®NC300II Nurse Call System Tek-CARE® NC200, NC150, NC110 Nurse Call Systems Tek-CARE®500 Wireless Emergency Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF340B Emergency Switch IL509 Specification Sheet Tek-CARE®400 P5 & NC300II Nurse Call Systems • Rev. 17 - 11/2012 Features • • • • • • • UL® 1069 Listed Simple and flexible operation Call-placed indicator Call cancel at point of origin Flame-retardant (UL® 94V-0) plastic faceplate 1.1" (28 mm) wide pull-down lever Washable TPU plastic pull cord kit is included Description The SF340B Emergency Switch is for use in any location where activation of an emergency signal is required. All electronic components are mounted on a circuit board. The specially mounted LED is completely sealed in plastic. Due to the flexibility of its design, the SF340B may be used as a pull cord emergency switch, a pull down activated emergency switch, or a staff assist emergency call switch. The pull cord supplied may be used for emergency call activation or, if desired, the large 1.1" (28 mm) red pulldown lever may be used. Dome light and system annunciation vary according to the manner in which the SF340B is connected. SF340B Emergency Switch (pull cord not shown) Listings UL® 1069 listed; UL® File Number E71599. Specifications Dimensions: Construction: Connections: Housing: Height: Width: Depth: Projects: 4.5" (114 mm) 2.8125" (72 mm) 1.625" (41 mm) 0.6875" (17 mm) from mounting surface (including pull-down lever) Flame-retardant (UL ® 94V-0) plastic faceplate. Switch and electronic components are circuit board mounted. Plug-in connectors. Single gang ring (IH357) with square box (IH358), or exact equal. Applicable Systems Tek-CARE®400 P5 Nurse Call System Tek-CARE®NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF341B Code Call Switch IL510 Specification Sheet Tek-CARE®400 P5 & NC300II Nurse Call Systems • Rev. 15 - 11/2012 Features • • • • • • • • • UL® 1069 Listed Supervised Registers audible and visual calls at master station Indicates local call origination on dome lights Simple and flexible operation Call-placed indicator Call cancel at point of origin Flame retardant (UL® 94V-0) plastic faceplate 1.1" (28 mm) wide pull-down lever Description The SF341B Code Call Switch operates all system code signals, and is designed for use in ICU/CCU, physical therapy rooms, post-op recovery, or any location where code call initiation may be required. The large 1.1" (28 mm) blue pull-down lever is used for code call activation. The red callplaced LED indicator flashes to provide for call assurance. Calls are registered on the master station (and duty station, if used) via audible and visual signals pulsing at a rate of twice that of a standard emergency signal. Local indication on dome lights is also provided. Call cancellation is possible only at the originating location. SF341B Code Call Switch Listings UL® 1069 listed; UL® File Number E71599. Specifications Dimensions: Construction: Connections: Housing: Height: Width: Depth: Projects: 4.50" (114 mm) 2.8125" (72 mm) 1.625" (41 mm) 0.6875" (17 mm) from mounting surface (including pull down lever) Flame retardant (UL® 94V-0) plastic faceplate. Switch and electronic components are circuit board mounted. Plug-in connectors. Single gang ring (IH357) with square box (IH358), or exact equal. Applicable Systems Tek-CARE®400 P5 Nurse Call System Tek-CARE®NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF381 Emergency & SF382 Code Standalone Stations IL753 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 4 - 07/2013 Features • • • • • UL® 1069 Listed Plug-on connection Supervised connections Standalone installation SF381 includes a washable TPU plastic pull cord kit Description The SF381 Emergency Station and the SF382 Code Call Station are for use in any location where an emergency or code call switch is needed without the need to install another device (such as a multipurpose station or other addressable device). The stations are designed to be connected directly to the station bus wiring of the Tek-CARE® NC300II system. The stations include dome lamp outputs, and are addressed using dip switches mounted on the rear of the stations. Listings UL® 1069 listed; UL® File Number E71599. SF381 Emergency & SF382 Code Standalone Stations Specifications Dimensions: Height 4.5″ (114 mm) Width:2.8125″ (75 mm) Depth:1.625″ (41 mm) Projects:0.6875″ (17 mm) (Including pull-down lever) Construction: Flame-retardant (UL® 94V-0) plastic faceplate. Electronic components are mounted on a printed circuit board. Connections: Plug-on connectors. Housing: Single gang ring or double gang box with single gang ring. Required Components Tek-CARE® NC300II Nurse Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF380A Visual-Only Patient Station IL866 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 4 - 04/2014 Features • • • • • Call-placed indicator Signaling for routine, bath emergency, code, and fire with smoke detectors Low power requirements Addressable—requires no IR-series station Station-bus connector pin-compatible with existing IR-series stations Description The SF380A Visual-Only Patient Station controls two dome light bulbs, senses button presses and switch closures, and provides routine, bath emergency, and code calls (when partnered with the proper peripheral switches) to the Tek-CARE® NC300II central equipment for display at the system master stations. The SF380A provides routine call input via a push-button call cord, and can signal a cord out call. When used with an emergency switch, it provides a medium priority bath emergency call. When used with a code switch, it provides a high priority code call. The SF380A also has a smoke detector input. Station addressing uses a 7-position dipswitch. Six switches set the station address; the seventh switch determines whether lamps are supervised. The SF380A is a drop-in replacement for the SF380C, with dipswitchselectable lamp supervision. Listings UL® 1069 listed; UL® File Number E71599. SF380A Visual-Only Patient Station Specifications Dimensions:Height: 4.5″ (114 mm) Width:2.75″ (69 mm) Depth:2.5″ (64 mm) Projects:0.4375″ (11 mm) Construction: Flame-retardant (UL® 94V-0) plastic faceplate. All electronic components are circuit-board mounted. Connections: Plug-in connectors for all wiring. Housing: Single-gang ring & double-gang back box. Required Components Tek-CARE® NC300II Nurse Call System LI380, LI382 or LI384A Corridor Dome Light SF301A Push-button or SF301G Geriatric Call Cord www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF301A, SF302 Call Cords IL338 Specification Sheet Tek-CARE® Nurse Call Systems • Rev. 18 - 06/2013 Features • • • • • UL® 1069 Listed Oxygen safe Impact resistant and waterproof Small, lightweight pendant fits comfortably in hand Bed clips included Description The TekTone® SF301A (single) or SF302 (double) call cords are for use with the Tek-CARE® NC110N, NC150N, NC200N and NC300™II Nurse Call Systems, and the Tek-CARE®500 Wireless Emergency Call System, where ¼″ phono jacks are used. Ten-foot cords are also available as SF301A/10 and SF302/10. The SF301A and SF302 are oxygen safe call cords certified safe for use by all patients receiving oxygen therapy. These waterproof and impact resistant call cords have completely sealed push buttons. Listings UL® 1069 Listed; UL® File Number E71599. Specifications Connection:¼″ (6.35 mm) plug-in phono jack Construction: SPST-1A switch Integral brass, fine silver contacts 1 AMP, 115 watt maximum, AC Dimensions: 7′ (2.13 m) long polyvinyl covered cord SF301A, SF302 Call Cords Required Components Tek-CARE®500 Wireless Emergency Call System with SF530 Room Station or Tek-CARE® NC300™II Nurse Call System with SF380A Patient Stations or Tek-CARE® NC200N or NC150N Nurse Call Systems with IR151B or IR152B Patient Stations or Tek-CARE® NC110N Nurse Call System with SF100C or SF102 Patient Stations www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SF301G, SF302G Call Cords IL434 Specification Sheet Tek-CARE® Nurse Call Systems • Rev. 15 - 06/2013 Features • • • • • • UL® 1069 Listed Sensitive touch activation Oxygen tent safe Ideal for geriatric use Momentary, air-activated switch Adjustable bed clip(s) Description TekTone® SF301G and SF302G Call Cords are for use with the Tek-CARE® NC110N, NC150N, NC200N and NC300II Nurse Call Systems, where ¼″ phono jacks are used. Patient stations include SF100C, IR151B, IR152B, SF380C, SF380P and SF530. SF301G and SF302G Call Cords are specifically designed for use in geriatric and oxygen environments, but may also be used in general applications. To place a call, the patient applies slight pressure to the squeeze bulb using any part of the body. The force of air through the vinyl tubing closes a switch in the plug, thus placing a call. An adjustable bed clip is supplied for the SF301G and is attached to the call cord. Two adjustable bed clips are supplied with the SF302G. Listings UL® 1069 Listed; UL® File Number E71599. Specifications Switch: Momentary contact, air activated Plug: Stainless steel Cord: Vinyl tubing Electrical: Rated current 1/3 amp, 24 VAC-VDC Dimensions:Cord: 6′ long (1.83 m) Plug:1.25″ long (32 mm) Bulb:1.5″ diameter(38 mm) SF301G Call Cord Required Components Tek-CARE®500 Wireless Emergency Call System with SF530 Room Station or Tek-CARE® NC300™II Nurse Call System with SF380A Patient Stations or Tek-CARE® NC200N or NC150N Nurse Call Systems with IR151B or IR152B Patient Stations or Tek-CARE® NC110N Nurse Call System with SF100C or SF102 Patient Stations www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) JK300A, JK300/2 Monitor Call Interface IL558 Specification Sheet Tek-CARE® Nurse Call Systems • Rev. 10 - 11/2012 Features • • • Easy installation Mounted on a flame-retardant (UL® 94V-0) plastic panel Simple, reliable operation Description The JK300A Monitor Call Interface is for use in applications where a simple interface is needed to connect the monitor input of an IR300-series or IR400P5-series station to an external contact closure. The JK300A accepts a standard ¼" phono-type jacks and registers a monitor call if a plug is removed. A ¼" dummy plug is included for use when the monitor point is not connected to an external device. The JK300/2 Monitor Call Interface provides two ¼" jacks and two dummy plugs. Specifications Dimensions: Construction: Connections: Housing: Height: Width: Depth: Projects: 4.5" (114 mm) 2.75" (70 mm) 1.5" (38 mm) 0.25" (6.5 mm) from mounting surface Reliable components mounted on a flameretardant (UL® 94V-0) plastic panel Wire lead pigtails Single-gang electrical box or ring JK300A, JK300/2 Monitor Call Interface Applicable Systems Tek-CARE®400 P5 Nurse Call System IR400P5-series Multipurpose, Patient, Resident, CheckIn, Staff or Duty Stations -or- Tek-CARE®400 Nurse Call System PM423 Auxiliary Input Module IR400-series Multipurpose, Patient, Resident, Check-In, Staff or Duty Stations -or- Tek-CARE®NC300II Nurse Call System IR300-series Multipurpose, Patient, Staff or Duty Stations www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) PM368K Short Haul Modem Kit IL833 Specification Sheet Tek-CARE®NC300II Nurse Call System • Rev. 4 - 07/2013 Features • • • • Converts RS232 signaling to RS422 Transmits up to 2000′ Uses CAT5 cabling Provides CTS/RTS for supervision functionality. Description TekTone®’s PM368K Short Haul Modem Kit increases the distance of serial signaling data by converting RS232 signaling to RS422 signaling. This extends the distance (using CAT5 cable) to 2000′ between a Tek-BRIDGE™ and a serial printer, Tek-PAGING® system, Tek-CARE®NC300II Central Equipment, or a monitored foreign system. Specifications Electrical: Rated 12VDC@100mA DC connectors Dimensions: Transformers: 2.2″×1.7″×1.5″ with 5.6′ cable Short Haul Modems: 2.2″×1.7″×0.65″ CT549 with CA132: 2′ Other Cable Assemblies: 1′ Cable distance: up to 2000′ CAT5 PM368K Short Haul Modem Kit Required Components for the Tek-CARE® NC300II Nurse Call System: Tek-PAGING® Paging System, or Serial Printer, or Tek-MMARS®300 Management Monitoring and Reporting System for the Tek-CARE®500 Wireless Emergency Call System: Tek-PAGING® Paging System, or Serial Printer for the Tek-ALERT™ Integration Manager: Foreign System to be monitored, Tek-PAGING® Paging System, or Serial Printer www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) NC365B Paging Transmitter IL670 Specification Sheet Tek-CARE® Nurse Call Systems • Rev. 12 - 10/2015 Description The NC365B Paging Transmitter receives alphanumeric messages and patient call information via serial interface and transmits the information directly to pagers. Information is sent to the transmitter at 9600 baud to minimize bottlenecks. Call type and location are determined by the system supplying information to the transmitter. The NC365B Paging Transmitter is pre-programmed for use with TekTone® systems for simplified plug-and-play setup. The system’s range depends upon the site and the transmitter’s location. To determine the exact coverage, conduct a site survey. Under ideal conditions, the NC365B Paging Transmitter’s range is approximately one mile. The unit includes a ¼-wave BNC-terminated antenna to provide coverage that meets most requirements. Specifications Dimensions:7.48″ × 12.99″ × 2.76″ (190 mm × 330 mm × 70 mm) NC365B Paging Transmitter Clearance:7.87″ (200 mm) minimum clearance on all sides Ports: Scope protocol RS232 serial DB9 COMP2 protocol RS232 serial DB9 8 dry contact inputs configured as Normally Open (#8 is preprogrammed to send RANGE TEST to CAP code 400 using included dummy plug.) Housing: Surface mounted Frequency: 457.55 MHz Channel Spacing: 12.5 KHz Adjacent Channel: better than 200nW @ 4.5 KHz deviation Baud Rate: 9600 serial input 1200 transmit Power: 115 VAC 0.8A, 50/60 Hz input 2 Watt output Consumption less than 50mA standby; up to 2.4A transmit 13.8 Volts DC operating voltage Optional Components BA365K Battery Backup Kit Required Components NC397A Pagers plus one of these systems: • Tek-CARE®400 P5 Nurse Call System • Tek-CARE®400 Nurse Call System • Tek-CARE®NC300II Nurse Call System • Tek-CARE ® NC110/150/200 Nurse Call System (requires NC377-series Paging Interface Adapter/ Voltage Interface) • Tek-CARE®500 Wireless Emergency Call System • Tek-ALERT® Alert Integration System Each paging system installed in the United States is required by law to have an FCC license. The FCC license can be obtained directly by the end user or through an authorized agent. The FCC application process takes approximately two weeks and provides the end user with a ten-year renewable license. To apply for an FCC license, visit: wireless.fcc.gov/index.htm?job=online_filing. Paging is an ancillary method of call annunciation, and is not intended to replace the primary annunciation provided by the nurse call system. www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) NC397A Alphanumeric Pager (Scope Geo 40A9) IL734 Specification Sheet Tek-CARE® Nurse Call Systems • Rev. 9 - 03/2015 Features • • • • • • • • • Alphanumeric 2-line 20-character backlit display Easy to use large 4-button design Preprogrammed with up to 8 user-specified CAP codes 4 vibrate patterns and 5 tone alert styles Real-time clock Message time stamping Low battery indicators Includes holster belt clip and bungee safety cord Description The NC397A alphanumeric pager is a radio pager with a large 2-line display. It includes a holster/belt clip and bungee safety cord. The pager is designed for use with TekTone®’s Tek-CARE® nurse call systems, Tek-CARE®500 wireless emergency call system, and Tek-ALERT® alert integration system. The pager stores up to 60 messages of 239 characters each. Messages may be selectively deleted or locked into memory. Messages not locked into memory are automatically deleted as new messages arrive (beyond the 60 message limit), with the oldest messages deleted first. The NC397A Pager may be configured for annunciation via vibration or audible tones, and has one alarm for daily annunciation. It can be programmed to turn on and off at preset times each day. The NC397A Pager is pre-programmed to receive call information from TekTone® systems. Specifications Dimensions: 2.087″ × 2.99″× 0.67″ (53 mm × 76 mm × 17 mm) without holster belt clip Weight: 1.76 oz. (50 g) without battery Protocol: POCSAG Operating Freq.:457.550 Mhz Power: 1 AAA battery NC397A Alphanumeric Pager Required Components NC365B Paging Transmitter plus one of these systems: • Tek-CARE®400 P5 Nurse Call System • Tek-CARE®400 Nurse Call System • Tek-CARE®NC300II Nurse Call System • Tek-CARE ® NC110/150/200 Nurse Call System (requires NC377-series Paging Interface Adapter/ Voltage Interface) • Tek-CARE®500 Wireless Emergency Call System • Tek-ALERT® Alert Integration System Paging is an ancillary method of call annunciation, and is not intended to replace the primary annunciation provided by the nurse call system. www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.) SI005 LED Messaging Sign IL890 Specification Sheet Tek-ALERT® and Tek-CARE®400, 400 P5, 500 & 550 Systems • Rev. 5 - 04/2015 Features • • • • • • One-line backlit LED display Displays 10 to 40 alphanumeric characters per line Configurable for audible alerts Programmable for up to 6 CAP codes Wireless data input Receives text messages from Tek-CARE® and TekALERT® systems SI005 LED Messaging Sign Description The SI005 LED Message Sign is a radio paging receiver with a large one-line alphanumeric display. It is designed for use with TekTone®’s Tek-ALERT® Alert Integration Manager, Tek-CARE ®400 Nurse Call, Tek-CARE ®500 Wireless Emergency Call, and Tek-CARE®550 Wireless Nurse Call Systems. The SI005 stores up to 24 messages. The messages are deleted after a predetermined length of time. Messages are automatically deleted as new messages arrive (beyond the 24 message limit), with the oldest messages being deleted first. The SI005 may be configured for annunciation via audible tones. The SI005 has been pre-programmed to receive call information from TekTone® systems, and it can be programmed for up to six CAP codes. Specifications Dimensions: Weight: Construction: 28″ L × 6.75″ H (711 mm × 171 mm) 8.4 lbs. LED display board with RF paging circuitry enclosed in a plastic housing. Operating Freq.:457.550 Mhz Power supply: Input 115 VAC Required Component NC365B Paging Transmitter Applicable Systems Tek-ALERT® Alert Integration Manager Tek-CARE®400 P5 Nurse Call System Tek-CARE®400 Nurse Call System Tek-CARE®500 Wireless Emergency Call System Tek-CARE®550 Wireless Nurse Call System The LED message sign is an ancillary method of call annunciation, and is not intended to replace the primary annunciation provided by the nurse call system. www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • [email protected] Phone: (828) 524-9967 • Fax: (828) 524-9968 • Sales: Choose option 2 • Tech Support: Choose option 3 TekTone®’s quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.)