bergman
Transcription
bergman
bergman April - August 2016 Issue 2 Contents TOC-L . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2 Water purification . . . . . . . . . . . . . . page 3 Laboratory chemicals . . . . . . . . . . . page 3 Spectrophotometry . . . . . . . . . . . . . page 4 Nucleic acid purification . . . . . . . . . page 5 Nucleofection™ . . . . . . . . . . . . . . . . . page 6 Genome editing . . . . . . . . . . . . . . . . page 7 Mycoplasma detection . . . . . . . . . page 8 ChIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9 Epigenetics . . . . . . . . . . . . . . . . . . . . page 9 Augmented microscopy . . . . . . . page 10 Heat-On™ Block System . . . . . . . page 11 Plate washer . . . . . . . . . . . . . . . . . page 12 Microplate readers . . . . . . . . . . . . page 12 NanoDrop™ One . . . . . . . . . . . . . . page 13 Laboratory evaporation . . . . . . . . page 14 Media preparation . . . . . . . . . . . . page 15 Labeling and detection . . . . . . . . page 16 BioNordikaBergman AS • tel 23 03 58 00 • [email protected] • www.bionordikabergman.no 2 • The picture on the cover is copyright ELGA Veolia Purified water for Clinical Analyzers Clinical analyzers need to receive a constant and reliable supply of compliant water to produce and reproduce diagnostic tests accurately. Water quality below accepted standards affects the accuracy of the results, and significantly impacts running costs. Our MEDICA range delivers consistent water quality and can feed a single clinical analyzer, large automated analyzers and multiple analyzers on a distribution loop. The MEDICA water purification systems all feature: • Flow rates from 7 liters up to 200 liters an hour (1 to 52 US Gallons an hour) • Meets Clinical Laboratory Reagent Water (CLRW), (formally CLSI Type I) standard • Bypass loop for continual supply of compliant water in emergency situations to the analyzer • Service support for maximum operational time • Low consumable and running costs © ELGA Veolia Our ELGA team can work together with project managers, installation engineers, facility managers and clinical scientists to provide help and expertise at all stages from concept and design through to the build and installation. Which MEDICA water purification system should you use? It is very important to use the correct water quality which meets both the application and analyzer usage requirements. Contact us and we will help you find the system best suited for your needs. Do you have questions about water purification? Contact Monica Laukas at 404 40 960 [email protected] Laboratory Chemicals PanReac AppliChem with almost 75 years experience in the manufacturing of chemical products provides their customers the widest range and highest quality of laboratory reagents. They are specialists in the manufacture of inorganic salts, high purity acids and solvents and other products for special applications, guaranteeing compliance with our customers’ specifications. Their catalogue includes more than 3500 products for laboratory chemical use as for example: • • • • • • • • • • Analytical reagents according to ACS, ISO, Ph. Eur. and or USP High purity solvents for spectroscopy, HPLC and GC Ultra pure acids for trace metal analysis Standard volumetric solutions pH buffers Reagents and solvents for organic synthesis Standards for IC, ICP and AAS Reagents for specific applications as Karl Fischer analysis or Kjeldahl analysis Reagents for clinical diagnosis Auxiliary products as detergents and pH indicator papers 3 Spectrophotometry UV-1800 Double Beam Spectrophotometer • Wavelength range: 190-1100 nm • Spectral bandwidth: 1 nm • Stray light; 0,02% (220 nm, Nal) Campaign Price: Kr. 56 000,- UV-2600 Spectrometer Variable spectral bandwidth • • • • Wavelength range 185-900 nm Option 220-1400 nm Variable Spectral bandwidth: 01nm to 5 nm Stray light 0,005% (220 nm, Nal) Campaign Price: Kr. 89 950,- UV-1280 Spectrometer Our smallest UV-VIS single beam spectrophotometer • Wavelength range 190-1100 nm • Spectral bandwidth 5 nm • Stray light <0,05% (220 nm, Nal) Campaign Price: Kr. 35 500,- UV-2700 Spectrometer Variable spectral bandwidth and very low stray light • • • • Double monochromator Wavelength range 185-900 nm Variable bandwidth 0,1 til 5 nm Stray light: 0,00005% (220 nm, Nal) Campaign Price: Kr. 104 000,- Do you want to learn more about Spectrometry? Contact Hanne Ramstad at 414 79 591 [email protected] 4 © All pictures on this page are copyright Shimadzu and gel purification needs New! Monarch nucleic acid purification kits! Monarch DNA Cleanup Kits rapidly and reliably purify up to 5 µg of concentrated, high-quality DNA. These kits utilize a bind/wash/elute workflow with minimal incubation and spin times. The columns provided with each kit ensure zero buffer retention and no carryover of contaminants, enabling elution of sample in volumes as low as 6 μl. Monarch Buffers have been optimized, and do not require monitoring of pH. Eluted DNA is ready for use in restriction digests, DNA sequencing, ligation and other enzymatic manipulations. advantages • Elute in as little as 6 µl Monarch Plasmid Miniprep Kit Advantages: • • • • • • Elute in low volumes Prevent buffer retention and salt carry over with optimized column design Reduce hands on time with faster protocols and less spin time Monitor completion of certain steps using colored buffer system No need to add RNaseThebefore Monarch starting DNA Gel Extraction Kit can be used to quickly purify DNA from Easily label columns using and other frosted surfaces agarose tab gels. Unlike kits, there is no need to add isopropanol to the melted Monarch DNA Gel Extraction Kit • Prevent buffer retention and salt carryover with optimized column design • Save time with fast, user-friendly protocols specifications • Binding Capacity: up to 5 µg • DNA Size Range: ~50 bp to 25 kb • Typical Recovery: DNA (50 bp to 10 kb): 70–90% DNA (11–25 kb): 50–70% • Elution Volume: ≥ 6 µl • Purity: A260/280 ≥ 1.8 agarose prior to loading on the column, saving you a step. • Protocol Time: Gel Extraction: 10 min of spin and incubation time. PCR & DNA Cleanup: 5 min of spin and incubation time Specifications: Monarch PCR & DNA • Culture Volume: 1–5 ml • Binding Capacity: up to 20 μg Cleanup Kit (5 µg) • • • • • • • Compatible Downstream Applications: ligation, restriction digestion, labeling and other enzymatic manipulations, library construction and DNA sequencing Plasmid Size: up to 25 kb The Monarch PCR & DNA Cleanup Kit (5 µg) can be used to purify DNA from Typical Recovery: up to 20 μg. Yield depends on plasmid copy number, host strain, culture volume, and growth conditions a variety of enzymatic reactions, such as PCR, restriction digestion, ligation Elution Volume: ≥ 30 and μl reverse transcription. The DNA Wash Buffer provided ensures enzymes, primers (≤ 25 Purity: A260/280 andshort A260/230 ≥ nt), 1.8detergents and other low-molecular weight reaction components (e.g., nucleotides, DMSO, betaine) are removed. Protocol Time: 10½ minutes of spin and incubation time Compatible Downstream Applications: restriction digestion and other enzymatic manipulations, transformation, transfection of robust cells, DNA sequencing, PCR, labeling, cell-free protein synthesis, etc. The improved design of the columns supplied with the Monarch Gel Extraction and PCR & DNA Cleanup Kits enables elution in as little as 6 µl, and eliminates buffer retention Optimized column The improved design of the columns supplied with the Monarch Gel Extraction and PCR & DNA Cleanup Kits enables elution in as little as 6 μl, and eliminates buffer retention. This is a great, easy-to-use, small footprint kit... it was great to elute in such a small volume while feeling confident Monarch DNA Gel Extraction Kit that the elution buffer managed to get to all & DNA Cleanup Kit of Monarch the surface areaPCR of the&membrane. – Michelle, Principal Investigator, Central Michigan University, Mount Pleasant, Michigan Made with less plastic for reduced environmental impact Unique, tapered design eliminates buffer carryover & allows for elution in as little as 6 μl Column tip is compatible with vacuum manifolds Product Cat.no. Size Monarch PCR & DNA Cleanup Kit (5 μg) T1030S/L 50/250 preps Monarch Plasmid Miniprep Kit T1010S/L 50/250 preps Monarch DNA Cleanup Columns (5 μg) T1034L 100 columns Monarch Plasmid Miniprep Columns T1017L 100 columns Monarch DNA Cleanup Binding Buffer T1031L 235 ml Monarch DNA Wash Buffer T1032L 25 ml Advantages: • • • Elute in as little as 6 μl Prevent buffer retention and salt carry over with optimized column design Save time with fast, user-friendly protocols Specifications: • Binding Capacity: up to 5 μg Visit NEBMonarch.com to request a•sample. DNA Size Range: ~50 bp to 25 kb Monarch DNA Gel Extraction Kit T1020S/L 50/250 preps Columns available separately Buffers available separately Monarch DNA Elution Buffer T1016L 25 ml Monarch Gel Dissolving Buffer T1021L 235 ml Monarch Plasmid Lysis Buffer (B2) T1012L 2 x 27 ml Monarch Plasmid Neutralization Buffer (B3) T1013L 110 ml Monarch Plasmid Resuspension Buffer (B1) T1011L 55 ml Monarch Plasmid Wash Buffer 1 T1014L 2 x 27 ml Monarch Plasmid Wash Buffer 2 T1015L 30 ml • • • • • Typical Recovery: DNA (50 bp to 10 kb): 70–90% DNA (11–25 kb): 50–70% Elution Volume: ≥ 6 μl Purity: A260/280 ≥ 1.8 Protocol Time: Gel Extraction: 10 min of spin and incubation time. PCR & DNA Cleanup: 5 min of spin and incubation time Compatible Downstream Applications: ligation, restriction digestion, labeling and other enzymatic manipulations, library construction and DNA sequencing Questions about Monarch Nucleic Acid Purification? Contact Gitika Emberland at 940 07 207 [email protected] © All pictures on this page are copyright NEB 5 Nucleofector™ Devices Nucleofection™ A Revolution in Electroporation Electroporation is a transfection technology based on the momentary creation of small pores in cell membranes by applying an electrical pulse. Lonza’s Nucleofector™ Technology is an improved electroporation technology that can help you achieve transfection results never before possible in primary cells, stem cells and hard to transfect cell lines with standard electroporation. In contrast to classical electroporation, with Nucleofection high efficiencies can be reached using much lower substrate amounts and with only moderate impact on viability. The comprehensive way in which Nucleofector™ Programs and cell typespecific solutions are developed enables nucleic acid substrates delivery not only to the cytoplasm, but also through the nuclear membrane and into the nucleus. This allows for high efficiencies up to 99% and makes the transfection success independent from any cell proliferation. 4D-Nucleofector™ system 1-16 samples per run Cell range per sample from 104 to 107 Y-unit for transfection of adherent cells 96 wells Shuttle™ system Up to 96 samples per run Cell range per sample from 104 to 106 The Nucleofector™ Technology Relies on a Unique Combination of: • • • A Nucleofector™ Device: Delivering optimized electroporation parameters pre-programmed for each optimized cell type Nucleofector™ Kits for primary cells or cell lines: Containing a specific Nucleofector™ Solution that provides a protective environment that allows for high transfection efficiency and cell viability, while helping to maintain physiologically relevant cellular functions Cell-specific Optimized Protocols: Providing optimal Nucleofection™ Conditions and comprehensive guidance, including tips for cell sourcing, passage, growth conditions and media, and post-transfection culture Benefits over Standard Electroporation at a Glance • • • • • Electroporation parameters are optimized to gain high transfection efficiency and retain highest viability Excellent preservation of the physiological status of transfected cells More than 650 cell-type specific protocols for direct transfection success with a multitude of different cell types Highly-skilled scientific support team to assist you in your research Invention of Nucleofection of cells in adherence Genome Editing - Successful Transfection of CRISPR & Co. using Nucleofector™ Technology HT Nucleofector™ system Up to 384 samples per run Cell range per sample from 104 to 106 Nucleofector™ 2b system 1 sample per run Cell range per sample from 105 to 106 6 © All pictures on this page are copyright Lonza All genome editing tools require co-transfer of several substrates into the cell type of interest for successful modification of genomic DNA. Lonza’s non-viral Nucleofector™ Technology has been shown to work as a reliable and sufficient method for transferring the required DNAor RNA-based components into various cell lines and primary or stem cells, e.g., primary T cells, human embryonic stem cells (hESC) or induced pluripotent stem cells (iPSCs). • • • • High transfection efficiencies for a broad range of cell types, including iPSCs Efficient co-transfection of various substrates Same conditions for transfecting plasmids, DNA, mRNA or PCR cassettes, ssODN Proven for ZFN, TALEN and CRISPR by more than 30 publications, including high ranking journals Do you want to learn more about Nucleofection? Contact Kristin Lundemo at 992 27 101 [email protected] NEB offers Cas9 NLS and other tools that support Genome Editing Workflows. Visit international.neb.com/genomeediting to learn more about the basics of CRISPR/Cas and related applications 7 Mycoplasma detection Mycoplasma Contamination in Cell Cultures One of the most common contaminants present in cell culture laboratories are mycoplasma1. A conservative estimate states that between 15-35% of all continuous cell cultures are contaminated with mycoplasma, some estimates are even higher (up to 80% in some countries2). Mycoplasma Effects on Your Cell Culture Typical routes of infection are cross-contamination from untested infected cells (e.g. via aerosols generated during pipetting, use of same media bottles, handling of more than one cell type at one time), contaminated materials, contaminated donor tissue (<1%) or direct infection from the researcher. The primary source is normally cross-contamination from infected cultures. Mycoplasma grow slowly and do not kill the cells outright but affect various cellular parameters 1,3,4,5,6,7,8,9,10,11. Thus, mycoplasma contaminations can seriously impact the reliability, reproducibility, and consistency of experimental results, representing a major problem for basic research as well as for the manufacturing of bioproducts. Standard testing for mycoplasma is an important quality control. Detect, Eliminate and Prevent Mycoplasma Contamination Lonza provides a powerful product offering for reliable detection and successful elimination and prevention of mycoplasma contaminations: • • • Detection: Easily detect mycoplasma using the MycoAlert™ PLUS Mycoplasma Detection Kit with your own luminometer or Lonza’s single-tube Lucetta™ Luminometer tailormade with a MycoAlert™ Protocol wizard Elimination: Efficiently eliminate mycoplasma with the MycoZap™ Elimination Reagent Prevention: Reliably prevent mycoplasma with MycoZap™ Antibiotics or MycoZap™ Spray Product Cat.no. Size MycoAlert™ PLUS detection kit LT07-701 10 tests MycoAlert™ PLUS detection kit LT07-703 30 tests MycoAlert™ PLUS detection kit LT07-705 50 tests MycoAlert™ PLUS detection kit LT07-710 100 tests MycoAlert™ Assay Control Set LT07-518 10 tests MycoAlert™ PLUS detection kits Lucetta™ Luminometer Lucetta™ Luminometer AAL-1001 MycoZap MycoZap™ 1 treatment kit LT07-818 1 treatment MycoZap™ 5 treatment kit LT07-918 5 treatments MycoZap™ Plus-CL VZA-2011 10 x 1 ml MycoZap™ Plus-CL VZA-2012 1 x 20 ml MycoZap™ Plus-PR VZA-2021 10 x 1 ml MycoZap™ Plus-PR VZA-2022 1 x 20 ml MycoZap™ Prophylactic VZA-2031 10 x 1 ml MycoZap™ Prophylactic VZA-2032 1 x 20 ml MycoZap™ Spray VZA-2001 500 ml MycoZap™ Spray, Refill VZA-2002 1000 ml Mycoplasma References 1) Drexler HG, Uphof CC (2002). Cytotechnology 39: 75–90 2) Koshimizu K, Kotani H (1981). In: Procedures for the Isolation and Identification of Human, Animal and Plant Mycoplasmas (Nakamura, M., ed.), Saikon, Tokyo, 87-102 3) Gong H et al. (1999). Biochem Biophys Res Comm 261: 10-14 4) Ben-Menachem G et al. (2001). FEMS Microbiol Letters 201: 157-162 5) McGarrity MF et al. (1984). In Vitro 20: 1-18 6) Sokolova IA et al. (1998). Immunol Cell Biol 76: 526-534 7) Doersen CJ, Stanbridge EJ (1981). Mol Cell Biol 1: 321-329 8) Stanbridge EJ (1971). Bacteriological Reviews 35): 206-227 9) Darin N et al. (2003). BMC Biochem 4:15 10) Rottem S (2003). Physiol Rev 83: 417-432 Do you want to learn more about mycoplasma detection? 11) Miller C et al.(2003). Biotechniques 35:812-814 Contact Kristin Lundemo at 992 27 101 [email protected] 8 © All pictures on this page are copyright Lonza SimpleChIP® Enzymatic ChIP Kits from Cell Signaling Technology SimpleChIP® Enzymatic Chromatin IP Kits from Cell Signaling Technology are optimized to detect endogenous levels of protein-DNA interactions in both cultured cells and SimpleChIP® Plus Chromatin IP Kits offer the additional benefit of tissue sample analysis. These kits contain all reagents necessary to perform enzymatic digestion-based chromatin immunoprecipitation (ChIP) experiments quickly and easily, as well as positive and negative controls that ensure confidence in your results. These kits are available with either Protein G agarose or Protein G magnetic beads and contain all buffers and reagents needed to perform up to 30 ChIP assays. © Cell Signaling Technology Benefits include: • Enzymatic digestion of chromatin is milder than sonication and better preserves the integrity of the chromatin and antibody epitopes, which means increased IP efficiency • A detailed and easily scalable protocol optimized for analysis of tissue and cell samples is provided, saving your valuable time and reagents • All reagents and controls are included, saving valuable time and providing the proper experimental controls • These kits are used in-house for validation of our ChIP recommended antibodies, saving you the trouble of optimization • The included ChIP-grade magnetic beads are ideal for downstream ChIP-on-chip or ChIP-sequencing as they provide higher sensitivity and low background • Technical support is provided by the same scientists who developed and produce the kits, ensuring a thorough, fast, and accurate response 9 Augmented Microscopy™ capture analyze Cellular compartments are automatically segmented and analyzed. Annotation tools are available. annotate video Includes temperature, gas, humidity control and a movie maker for live cell time-lapse imaging. Lionheart™ FX Automated Live Cell Imager enables superior digital microscopy with high resolution images up to 100x. From simple fixed cell assays and slide scanning to advanced, environmentally controlled timelapse movies and 3D spheroid formation imaging, Lionheart FX and Gen5 3.0 Software provide qualitative and quantitative data in a compact automated microscopy system. Visit www.lionheartfx.com www.biotek.com 10 Heat-On™ Block System The safer alternative to oil baths Heat-On accepts vials, tubes and flasks from 10ml to 5 litres. Key Benefits: •Replace messy oil baths, heating mantles and avoid spills • Make your chemistry safer, cleaner and faster • Solid aluminium blocks provide even heating • Lightweight design allows rapid heating • Unique well design eliminates cracking of flasks • Blocks feature two probe holes for added convenience • Optional and detachable lifting handles • Optional PTFE Safety Covers reduce risk of user touching hot blocks • Block for Florentine (pear-shaped) flasks • Use up to 260˚C • Fit on all leading hotplate brands with a 145mm Ø top plate; optional adapter plate for 135mm Ø top plates Choice of block finishes: • Fluoropolymer coating gives superb chemical resistance • Anodised finish is durable, lower cost option Oli baths are messy, dangerous and costly: • Oil will discolour and degrade with repeated heating and contamination from chemicals, water and general debris • Degradation results in a dangerous lowering of the oil’s flashpoint as well as increased smoking and fumes • Oil should be regularly replaced to maintain a safe working environment • Disposal of oil waste must be done in an environmentally and safe way, with associated costs Special Offer! Buy 2 Heat-On™ products and get a 3rd free! Reasons for choosing Heat-On: Cleaner, greener, safer! The risk of oil fires and injury from hot oil spills, plus the mess and cost associated with the use of oil means that oil baths no longer represent safe working practice in labs. Heating mantles are expensive, difficult to clean, do not respond well to spills and often create hot spots when heating. Scientists are increasingly turning to specially designed aluminium blocks located on stirring hotplates to heat standard round bottom flasks. © Radleys Do you want to learn more about the products from Radleys? Contact Marte Tøften at 922 11 099 [email protected] 11 ELx50 strip washer • • • • • • • • • Washes 96- and 384-well microplates Magnetic and polystyrene bead assays ELISAs and cell-based assays Filtration-to-waste processes Patented Dual-Action™ wash manifold for independent control of dispense and aspiration tubes Comprehensive onboard software makes programming quick and easy Automatic switching for up to three wash buffers Programmable shaking duration and intensity Built-in maintenance programs Epoch & Take3 nanodrop plate A microplate reader and a nanodrop in one instrument • • • • • • • • • • Save valuable sample by using Take3 to quantitate 2 μL volumes of DNA, RNA and proteins Monitor cell growth using the Epoch’s well scanning capability Run spectral scans of 2 μL samples, or samples contained in a microplate or cuvette Dial in individual wavelengths from 200 – 999 nm Perform rapid qualitative or quantitative analysis in microplates from 6- to 384-wells Measure kinetic rates of reaction Run multiplex assays quickly and easily Save space on the benchtop with its very small footprint Avoid costly maintenance with the robust, thoughtfully engineered optics and hardware Never purchase costly absorbance filters MultiFlo FX Dispenser/Washer • • • • • • • Up to four independent reagents dispensed in parallel with no potential for carryover Unique Parallel Dispense technologies – choice of peristaltic or syringe pumps for unique assay requirements Large, high resolution color touch screen display Onboard computer with two USB flash drive ports for file transfer, storage and operation Optional plate washing module increases functionality Modular and upgradable ELISAs, cell-based assays (including automated staining and fixing for imaging) and bead-based assays such as Luminex xMAP® Do you want to learn more? Contact Hanne Ramstad at 414 79 591 [email protected] 12 © All pictures on this page are copyright BioTek MOLECUL AR SPECTROSCOPY Product Specif ications Thermo Scientific NanoDrop One Microvolume UV-Vis Spectrophotometers Intelligent microvolume analysis Thermo Scientific™ NanoDrop™ One microvolume UV-Vis spectrophotometers quantify and qualify DNA, RNA, and proteins in seconds using only 1–2 µL of sample. These next-generation NanoDrop instruments are built with Thermo Scientific™ Acclaro™ Sample Intelligence technology that helps you understand the quality of your sample before using it in downstream applications, bringing you one step closer to discovery. With contaminant analysis, sample information alerts and on-demand technical support, the Acclaro technology brings a new level of confidence in results, making NanoDrop One the ideal UV-Vis spectrophotometer for life science researchers. Easily transfer data from NanoDrop One standalone instrument to your computer via a USB device. Pipette. Measure. Know. Expect NanoDrop reliability and enhanced performance with these NanoDrop One advantages: Fast and easy evaluation of nucleic acids and proteins with Auto-Measure and pre-programmed applications Modern standalone design with local control and high-resolution touchscreen interface saves bench space Accurate measurements up to 27,500 ng/μL (dsDNA) with extended auto-range pathlength technology No consumables needed– pipette directly onto the pedestal sample-retention system Enhanced connectivity with data transfer via USB, Ethernet, Bluetooth® and Wi-Fi options; PC software available for data management Optional cuvette position for measuring dilute solutions and performing temperature sensitive experiments Know More with Acclaro Sample Intelligence Technology Make informed decisions on sample suitability for your application. Acclaro technology offers enhanced sample analysis with: • Contaminant identification and corrected results • Instant feedback about sample quality with on-demand technical support and guided troubleshooting • Embedded sensor and digital image analysis that ensures measurement integrity Add a Cuvette Position The Thermo Scientific™ NanoDrop™ OneC spectrophotometer adds experimental flexibility and increases the dynamic range. Use cuvettes to measure dilute samples and optical density of bacterial cultures or to perform kinetics experiments. Includes cuvette temperature control and stirring. Do you want to learn more about NanoDrop One? Contact Kristin Lundemo at 992 27 101 [email protected] 13 Laboratory Evaporation Rotavapor® R-300 Convenient and efficient rotary evaporation The Rotavapor® R-300 represents high reliability and convenience in laboratory rotary evaporation applications. The Rotavapor® R-300 is available with either an electronic or manual lift, and can optionally include the Heating Bath B-301 or B-305 and, a glass assembly of your choice and the Interface I-300 or I-300 Pro. All accessories and connections are included for out of the box usage. • • • • • • • • • Comfortable flask and vapor duct removal thanks to easy to use Combi-Clip User-friendly operation due to ergonomic electric or manual lift Immediate adjustment of heating temperature and rotation speed with intuitively positioned control knobs Easy plug & play extension to a fully integrated system including a central interface, vacuum pump and recirculating chiller according to your needs Choice between 5 L high-temperature and 1 L fast-heating bath Wide range of beneficial accessories available: seven different glass assemblies, safety shield, lid for heating bath, automatic distillation and automatic foam detection Precise operation control with integrated digital display of heating temperature, rotation speed and lift position Traceability of all process parameters including data recording and charting with the optional Interface I-300 Pro Instant alert with push notification on mobile devices in case of process deviation (with Interface I-300/I-300 Pro only) Reference: “The method-based guided operation simplifies the distillation task. Thus, we can entrust the lab assistants to safely perform a reproducible purification process using the Rotavapor® system, and dedicate ourselves to other tasks.” Dr. Yasuhiro Shirai, Group Leader Photovoltaic Polymer Materials Global Research Center for Environment and Energy based on Nanomaterials Science, GREEN, Japan. Rotavapor® R-100 Economical evaporation The Rotavapor® R-100 is a high-quality rotary evaporator to meet the essential needs in clas¬sical laboratory applications. It is capable of a manually adjustable rotation speed of 20 to 280 rpm and equipped with an action jack lift for manual lifting of the evaporating flask. Included is the selected condenser, 1 L receiving and evaporating flasks and a vapor duct. All accessories are included for out of the box usage. • • • • • • • Effective Rotavapor for limited budgets Fundamental design fulfills essential needs of evaporation Quick and ergonomic operation with manual lift mechanism Easy flask handling and vapor duct removal with Combi-Clip Easy operation by integrating interface, vacuum pump and recirculating chiller Expandable with a wide range of accessories and various glass assemblies Flexibility to use the independent heating bath for further applications Do you want to learn more about our rotavapors from Buchi? Contact Marte Tøften at 922 11 099 [email protected] 14 © All pictures on this page are copyright Buchi Media preparation MEDIAJET The MEDIAJET system offers the unique flexibility to fill Petri dishes of various sizes, Petri dishes with two compartments as well as test tubes of various diameters and length. At the same time, MEDIAJET requires only minimal bench space in the laboratory. • Easy handling: The intuitive, full size graphical user interface makes it very easy to control all functions of MEDIAJET. The operation of the system is entirely self-explanatory, as all functions and prompts are explained in plaintext. • Reliable walk-away automation: With the novel Feed-In / Stack-Out technology, MEDIAJET guarantees a reliable and completely user independent operation. Typical production variations in the diameter or shape of the Petri dishes are easily handled by the unit, as they are actively guided throughout the entire filling process. Moreover, the optical dish sensors of MEDIAJET can be easily adjusted to virtually every Petridish brand at the user interface level. • Media cost reduction: MEDIAJET has a built-in “Agar Spread Function” which ensures a homogenous distribution and an even surface of the agar. It helps to optimize the agar level in the Petri dish and thereby allows a significant reduction of media costs. • Eliminating sources of contamination: For consistent agar plate quality, a clean environment during the dispensing process is essential. The surface of the filling chamber is manufactured of a single piece of resistant PE, which allows convenient and efficient cleaning. In addition, MEDIAJET is equipped with a UV lamp extending over the full length of the rotor where the dishes are opened during the dispensing process. The lamp emits powerful 2.1 W UV-C radiation for optimal bactericidal efficiency in the area most vulnerable to contamination. • Biplate: For many applications, the amount of required agar can be reduced by using two-compartment Petri dishes. However, pouring biplates by hand is time-consuming and inefficient. With the MEDIAJET vario biplate option you have an efficient and reliable solution to fill two-compartment Petri dishes automatically. Dose IT peristatic pump Store Application Protocols. Up to 20 application protocols can be stored and recalled anytime. Compact Design This pump fits everywhere and can be moved easily. Large Display Allows for an intuitive programming and operation. Fliptop Pumphead Allows for an easy and quick tubing exchange Different tubing sizes. Compatible with tubing from 1 to 8 mm ID, DOSE IT allows fast and precise dispensing from 100 µl to several litres. Do you have questions about the products from Integra? Contact Monica Laukas at 404 40 960 [email protected] © All pictures on this page are copyright Integra 15 PIONEERS in State of the Art Labeling & Detection In Situ Hybridization DNA/RNA Applications Immunofluorescence Immunohistochemistry Multiple Antigen Labeling Neuronal Tracing Blot Detection Enzyme Immunoassays Glycobiology Studies Cellular Imaging Since 1976 As a U.S. based primary manufacturer of the highest quality detection reagents, Vector Laboratories is able to provide our products to customers in standard, bulk and OEM formats, at low cost directly from our facilities. Producers of innovative products including: VECTASTAIN® ABC Kits • ImmPRESS™ Enzyme Polymer Reagents • Mouse on Mouse (M.O.M.™) Kits • ImmPACT™ Substrates Avidin/Biotin Systems • Secondary Antibodies • NEUROBIOTIN™ Tracers • Lectins VECTASHIELD® Mounting Media w w w. v e c t o r l a b s . c o m BioNordikaBergman AS • tel 23 03 58 00 bergman • fax 23 03 58 01 • [email protected] • Promo code: NL-2/16 www.bionordikabergman.no Note! The promo code is required to obtain the special prices! The offers are valid until 31.08.16 and cannot be combined with other offers or agreements. The prices are listed excl. VAT and shipping charges. We reserve the right to typos. BioNordikaBergman AS • tel 23 03 58 00 • [email protected] • www.bionordikabergman.no
Similar documents
bergman
Accurate quantitation of next-generation sequencing libraries is essential for maximizing data output and quality from each sequencing run. Furthermore, for Illumina sequencing, accurate quantitati...
More information