PZ 06-24-2015 AGENDA with associated documents[Icon]
Transcription
PZ 06-24-2015 AGENDA with associated documents[Icon]
SCHERTZ PLANNING & ZONING COMMISSION HAL BALDWIN MUNICIPAL COMPLEX COUNCIL CHAMBERS 1400 SCHERTZ PARKWAY BUILDING #4 SCHERTZ, TEXAS 78154 City of Schertz Core Values Do the right thing Do the best you can Treat others the way you would want to be treated Work together cooperatively as a team AGENDA Wednesday, June 24, 2015 at 6:00 p.m. 1. CALL TO ORDER / ROLL CALL 2. RECOGNITION/OATH OF APPOINTED COMMISSIONERS 3. ELECTION OF CHAIRMAN AND VICE CHAIRMAN 4. HEARING OF RESIDENTS 5. WORKSHOP/DISCUSSION: Public hearing, presentation and discussion on proposed amendments to UDC, Sec. 21.9.5 Exterior A. Construction and Design Standards. 6. ITEMS FOR INDIVIDUAL CONSIDERATION: A. PC2015-015 Consider and act upon a request for approval of a preliminary plat of Rhine Valley Unit 2, an approximately 16 acre tract of land situated in the Miles S. Bennett Survey No. 75, Abstract No. 61, County Block 5057, the Julian Diaz Survey No. 66, Abstract No. 187, County Block 5059, and the William Bracken Survey No. 74, Abstract No. 43, County Block 5056, City of Schertz, Bexar County, Texas, generally located on Lower Seguin Road 3,000 feet east of the intersection of Lower Seguin Road and FM 1518. This time is set aside for any person who wishes to address the Planning and Zoning Commission. Each person should fill out the Speaker’s register prior to the meeting. Presentations should be limited to no more than three (3) minutes. Discussion by the Commission of any item not on the agenda shall be limited to statements of specific factual information given in response to any inquiry, a recitation of existing policy in response to an inquiry, and/or a proposal to place the item on a future agenda. The presiding officer, during the Hearing of Residents portion of the agenda, will call on those persons who have signed up to speak in the order they have registered. B. PC2015-018 Consider and act upon a request for approval of a preliminary plat of The Reserve at Schertz II, Unit 3, an approximately 19 acre tract of land situated in the S. B. Lewis Survey No. 317, Abstract No. 443, and the Antonio Zamora Survey No. 36, Abstract No. 82 City of Schertz, Bexar County, Planning & Zoning June 24, 2015 Page 1 of 2 Texas, generally located on Graytown Road 1,500 feet south east of the intersection of Boenig Drive and Graytown Road. 7. 8. REQUESTS AND ANNOUNCEMENTS: Requests by Commissioners to place items on a future Planning and Zoning Agenda. A. B. Announcements by Commissioners. City and community events attended and to be attended Continuing education events attended and to be attended C. Announcements by City Staff. City and community events attended and to be attended. NEW SITE PLAN APPLICATIONS: The following Site Plans were submitted to the Planning and Zoning Department between June 6, 2015 and June 18, 2015. 1. Windy Meadow Subdivision Unit 1, Lot 14, Block 2 (153 Windy Meadows Drive) - Site Plan- Proposed: 6,000 square foot office building 2. Schertz 15 Acre Industrial Site Subdivision, Lot 1, Block 1 (9850 Doerr Lane) Amended Site Plan – Proposed: 213,864 square foot office/warehouse 3. Schertz 3009 Subdivision II, Lot 2, Block 1 (289 FM 3009) Amended Site Plan – Proposed: 9,947 square foot retail and restaurant 4. Legacy at Forest Ridge, Lot 4, Block 2 (5001 Schertz Parkway) Site Plan Proposed: 11,535 square foot childcare and school ADJOURNMENT OF THE REGULAR MEETING CERTIFICATION I, Patti White, Executive Assistant Development, of the City of Schertz, Texas, do hereby certify that the above agenda was posted on the official bulletin boards on this the 19th day of June, 2015 at 1:00 p.m., which is a place readily accessible to the public at all times and that said notice was posted in accordance with chapter 551, Texas Government Code. Patti White _______________________ Patti White, Executive Assistant Development I certify that the attached notice and agenda of items to be considered by the Schertz Planning & Zoning Commission was removed from the official bulletin board on _____day of _______________, 2015. ____________________________title:__________________________ This facility is accessible in accordance with the Americans with Disabilities Act. Handicapped parking spaces are available. If you require special assistance or have a request for sign interpretative services or other services please call 619-1030 at least 24 hours in advance of meeting. The Planning and Zoning Commission for the City of Schertz reserves the right to adjourn into executive session at any time during the course of this meeting to discuss any of the matters listed above, as authorized by the Texas Open Meetings Act. Executive Sessions Authorized: This agenda has been reviewed and approved by the City’s legal counsel and presence of any subject in any Executive Session portion of the agenda constitutes a written interpretation of Texas Government Code Chapter 551 by legal counsel for the governmental body and constitutes an opinion by the attorney that the items discussed therein may be legally discussed in the closed portion of the meeting considering available opinions of a court of record and opinions of the Texas Attorney General known to the attorney. This provision has been added to this agenda with the intent to meet all elements necessary to satisfy Texas Government Code Chapter 551.144(c) and the meeting is conducted by all participants in reliance on this opinion. Planning & Zoning June 24, 2015 Page 2 of 2 PLANNING AND ZONING COMMISSION MEETING: June 24, 2015 Workshop/ Discussion Agenda Item – 5A TO: Planning and Zoning Commission PREPARED BY: Bryce Cox, Planner CASE: ZC2014-006 – UDC Sec.21.9.5 Exterior Construction and Design Standards – UDC Amendment SUBJECT: Public hearing, presentation and discussion on proposed amendments to UDC, Sec. 21.9.5 Exterior Construction and Design Standards. BACKGROUND: Workshop discussion on at the June 10, 2015 Planning and Zoning Commission Meeting. Commission requested photograph examples of material percentages. As stated in the UDC, City Council from time to time may make amendments, change or modify text to any portion of the UDC to establish and maintain sound stable and desirable development. It is generally considered good practice to periodically review and update the development regulations due to changing conditions, community goals and State and Federal regulations. UDC Sec. 21.9.5 Exterior Construction and Design Standards was identified as a section in need of revision. To assist with the revision to UDC Sec. 21.9.5 Exterior Construction and Design Standards, Planning Staff created a focus group. The Design Standards Focus Group was comprised of various architects, engineers, developers, and City Boards including Board of Adjustments, Schertz Economic Development Board, and Planning and Zoning Commission. Through brainstorming, guided discussions and a photo survey, the focus group diagnosed problems with the current design standards, identified the aspects which promote quality development, and developed the following goals for the new design standards: • • • Clear language- easy to understand and interpret Categorized by building type or what the building is used for Encourages creativity and innovation with sustainable materials GENERAL INFORMATION: Planning Staff drafted this amendment based on the recommendations and input from the Design Standards Focus Group. The revised design standards have been organized based on the intended use of the building. There are five building use categories; Industrial, Commercial, Office/Public, Multi-Family, and Single-Family Residential. This allows for specific standards to be appropriately applied to different building types. There are three design elements that were identified as contributing most to aesthetical appearance: 1. Building materials; 2. Glazing- amounts of windows and doors; 3. Articulations – vertical and horizontal breaks in the rhythm of a building. These three elements are regulated under the current design standards as well. The proposed amendment continues to regulate these elements, but also provides additional flexibility to encourage innovation and promote quality development. This amendment was sent on June 1, 2015 for review and comments to all the members of the focus group. At the time of this report no objections have been received. This amendment is currently under review by the City Attorney. PROPOSED AMENDMENTS: Materials: The current design standards require all Multi-Family and Non-Residential buildings to have a front façade of 100% masonry material, and each of remaining facades must be comprised of a minimum of 75% masonry materials. Masonry materials is defined as brick, stone, stucco, cementatious fiberboard, split face concrete masonry units, concrete with an aggregate finish and faux stone or brick. The proposed amendment provides flexible options for industrial, commercial, office/public and multi-family building types by allowing accent materials to be used on the front façade. Additionally for industrial and multifamily buildings the amendment provides an alternative of a 100% masonry front façade and a cumulative percentage of the entire building as masonry materials. The proposed amendment also specifies which masonry materials can be used on each of the building types. This allows for creativity and innovation in material usage while promoting quality development through the use of aesthetically appropriate materials for the various building types. Glazing: The current design standards require the front façade of commercial buildings to be comprised of 30% windows and doors that provide visibility into the building. Additionally the current design standards requires the front façade of industrial buildings in M-1 and M-2 zoning districts to be comprised of 15% windows and doors that provide visibility into the building. The current requirement does not provide any flexibility for distributing the required glazing around the building. The proposed amendment provides flexible glazing options for industrial, commercial and office/public building types by allowing the applicant to choose a set percentage of the front façade to be comprised of windows and doors or, to use a higher percentage of windows and doors that will be spread around the building. Additionally the proposed amendment clearly defines what side of the building is considered the front and provides additional requirements and options for buildings which front on two or more streets. Articulations: The current design standards require vertical and horizontal articulations on all walls which are longer than twice the walls height. The depth of the articulation is a percentage of the wall’s height. Additionally if a horizontal articulation is required, the length of the new plane created by the articulation must be at least 25% of the walls length. The current requirement is very wordy and lacks clarity in its language. 2 The proposed amendment provides clear language as to when articulations are needed and sets a minimum articulation depth of two feet (2’) instead of a variable percentage. Additionally the proposed amendment provides articulation criteria specific to each building type (industrial, commercial, office/public and multi-family) which allows for flexibility and aesthetics that cater to the specific building type. The proposed amendment regulates the building facades which are most visible to the public, allowing for synergy between the building form, function and aesthetics. Additional Changes: Building Expansions– The amendment proposes to make building expansions which cumulatively increase the gross floor area more than 25% of the original building area, comply with the design standards. This will allow existing older buildings which would like to make a small expansion be able to maintain the original building aesthetics. Single Family Residential Materials- The proposed amendment removes split face CMU from the list of approved masonry materials for a single-family residential dwelling. STAFF ANALYSIS AND RECOMMENDATION: The proposed amendment achieves all the goals created by the Design Standards Focus Group and will provide flexibility in building design while maintaining high standards of development. Staff will be recommending approval of the amendment to the Unified Development Code (UDC), Sec.21.9.5 – Exterior Construction and Design Standards at the June 24, 2015 Planning and Zoning Commission meeting. Attachments: UDC Sec.21.9.5 – Exterior Construction and Design Standards (UDC 11-S-15) UDC Sec.21.9.5 – Exterior Construction and Design Standards (Proposed Draft) 3 Sec. 21.9.5 Exterior Construction and Design Standards A. Intent It is the intent of these design criteria to provide guidelines for new construction in order to provide an aesthetically pleasing appearance as well as ensure sound construction quality. B. Applicability The provisions of this section are deemed to be minimum standards and shall be applicable to the following: 1. All new buildings within the corporate limits of the City; and 2. Building expansions which cumulatively increase the gross floor area more than 25% of the original building area. C. Industrial Buildings 1. Applicability This section shall apply to buildings with an industrial use. 2. Exterior Building Materials Buildings must comply with one of the following: a) At least 80% of each wall (excluding windows and doors) shall be finished in one or more of the following materials: • Brick • Stone • Faux brick or stone • Concrete tiltwall • Split face CMU • Stucco • Tile Or b) 100% of the front façade (façade adjacent to or facing a public street) and a total of 75% of the entire building (excluding windows and doors) shall be finished in one or more of the following materials: • Brick • Stone • Faux brick or stone • Concrete tiltwall • Split face CMU • Stucco • Tile 3. Glazing All buildings must comply with one of the following: a) At least 15% of the front facade (façade adjacent to or facing a public street) shall be comprised of windows or glass doors. For buildings that are adjacent to or face two or more Rev. 6-5-2015 1 public streets at least 15% of each façade adjacent to or facing a public street shall be comprised of windows or glass doors. For buildings that are not adjacent to or face a public street, but instead face or front a private drive, the facade that faces or fronts on the private drive that provides for primary access shall be considered as the front facade; Or b) Windows and doors may be spread around the building, the minimum amount of required windows or glass doors is calculated as 30% of the front façade (façade adjacent to or facing a public street). For buildings that are adjacent to or facing two or more public streets the minimum amount of required windows or glass doors is calculated as 20% of the total area of the façades adjacent to or facing public streets. 4. Articulation and architectural features a) Horizontal articulations or offsets are required on any wall greater in length than 100 linear feet, which is adjacent to or facing a public street. (1) The depth of the articulation or offset shall be a minimum of two feet (2’). Articulations or offsets can be of varying depth as long as the minimum two feet (2’) is met. (2) The length of the new plane created by the articulation or offset shall be a minimum of 20% of the total length of the entire wall. b) Vertical articulations or elevation changes are required on all walls and should be designed to screen rooftop equipment. (1) The height of the articulation or elevation change shall be a minimum of two feet (2’). Articulations or elevation changes can be of varying depth as long as the minimum two feet (2’) is met. (2) The length of the new plane created by the articulation or elevation change shall be a minimum of 20% of the total length of the entire wall. 5. Roof Treatments Façade articulations shall provide for vertical and horizontal screening of air conditioning units and all mechanical equipment located on rooftops. The minimum height of the screening shall be equal to the height of the tallest rooftop equipment. D. Commercial Buildings 1. Applicability This section shall apply to buildings with a commercial use. 2. Exterior Building Materials Buildings must comply with the following: a) At least 80% of each wall (excluding windows and doors) shall be finished in one or more of the following primary materials: • Brick • Stone • Faux brick or stone • Tile • Stuccob Rev. 6-5-2015 2 • • Concrete tiltwallc Split face CMUc. b) Stucco may be used in conjunction with one of the other approved primary materials. Stucco cannot be used for more than 50% of each façade. c) Concrete tiltwall and split face CMU may be used in conjunction with one of the other approved primary materials. Concrete tiltwall and split face CMU cannot be used for more than 30% of each façade. 3. Glazing All buildings must comply with one of the following: a) At least 30% of the front façade (façade adjacent to or facing a public street) shall be comprised of windows or glass doors. For buildings that are adjacent to or face two or more public streets at least 30% of each façade adjacent to or facing a public street shall be comprised of windows or glass doors. For buildings that are not adjacent to or face a public street, but instead face or front a private drive, the facade that faces or fronts on the private drive that provides for primary access shall be considered as the front facade; Or b) Windows and doors may be spread around the building, the minimum amount of required windows or glass doors is calculated as 60% of the front façade (façade adjacent to or facing a public street). For buildings that are adjacent to or facing two or more public streets the minimum amount of required windows or glass doors is calculated as 50% of the total area of the façades adjacent to or facing public streets. 4. Articulation and architectural features a) Horizontal articulations or offsets are required on any wall greater in length than 30 linear feet, which is adjacent to or facing a public street, or adjacent to or facing a side lot line of the property. (1) The depth of the articulation or offset shall be a minimum of two feet (2’). Articulations or offsets can be of varying depth as long as the minimum two feet (2’) is met. (2) The length of the new plane created by the articulation or offset shall be a minimum of 20% of the total length of the entire wall. b) Vertical articulations or elevation changes are required on all walls and should be designed to screen rooftop equipment. (1) The height of the articulation or elevation change shall be a minimum of two feet (2’). Articulations or elevation changes can be of varying depth as long as the minimum two feet (2’) is met. (2) The length of the new plane created by the articulation or elevation change shall be a minimum of 20% of the total length of the entire wall. 5. Roof Treatments Façade articulations shall provide for vertical and horizontal screening of air conditioning units and all mechanical equipment located on rooftops. The minimum height of the screening shall be equal to the height of the tallest rooftop equipment. Rev. 6-5-2015 3 E. Office/Public Buildings 1. Applicability This section shall apply to buildings with a professional office or public use. 2. Exterior Building Materials Buildings must comply with the following: a) At least 75% of each wall (excluding windows and doors) shall be finished in one or more of the following materials: • Brick • Stone • Faux brick or stone • Tile • Stucco • Concrete tiltwallb • Split face CMUb b) Concrete tiltwall and split face CMU may be used in conjunction with one of the other approved primary materials. Concrete tiltwall and split face CMU cannot be used for more than 30% of each façade. 3. Glazing All buildings must comply with one of the following: a) At least 25% of the front façade (façade adjacent to or facing a public street) shall be comprised of windows or glass doors. For buildings that are adjacent to or face two or more public streets at least 20% of each façade adjacent to or facing a public street shall be comprised of windows or glass doors. For buildings that are not adjacent to or face a public street, but instead face or front a private drive, the facade that faces or fronts on the private drive that provides for primary access shall be considered as the front facade; Or b) Windows and doors may be spread around the building, the minimum amount of required windows or glass doors is calculated as 50% of the front façade (façade adjacent to or facing a public street). For buildings that are adjacent to or facing two or more public streets the minimum amount of required windows or glass doors is calculated as 40% of the total area of the façades adjacent to or facing public streets. 4. Articulation and architectural features a) Horizontal articulations or offsets are required on any wall greater in length than 50 linear feet. (1) The depth of the articulation or offset shall be a minimum of two feet (2’). Articulations or offsets can be of varying depth as long as the minimum two feet (2’) is met. (2) The length of the new plane created by the articulation or offset shall be a minimum of 20% of the total length of the entire wall. Rev. 6-5-2015 4 b) Vertical articulations or elevation changes are required on all walls and should be designed to screen rooftop equipment. (1) The height of the articulation or elevation change shall be a minimum of two feet (2’). Articulations or elevation changes can be of varying depth as long as the minimum two feet (2’) is met. (2) The length of the new plane created by the articulation or elevation change shall be a minimum of 20% of the total length of the entire wall. 5. Roof Treatments Façade articulations shall provide for vertical and horizontal screening of air conditioning units and all mechanical equipment located on rooftops. The minimum height of the screening shall be equal to the height of the tallest rooftop equipment. F. Multi-Family Buildings 1. Applicability This section shall apply to buildings with a Multifamily Use. 2. Exterior Building Materials Buildings must comply with one of the following: a) At least 80% of each wall (excluding windows and doors) shall be finished in one or more of the following materials: • Brick • Stone • Faux brick or stone • Tile Or b) 100% of the front façade (façade adjacent to or facing a public street) and a total of 60% of the entire building (excluding windows and doors) shall be finished in one or more of the following materials: • Brick • Stone • Faux brick or stone • Tile 3. Articulation and architectural features a) Horizontal articulations or offsets are required on any wall greater in length than 10 linear feet. (1) The depth of the articulation or offset shall be a minimum of two feet (2’). Articulations or offsets can be of varying depth as long as the minimum two feet (2’) is met. (2) The length of the new plane created by the articulation or offset shall be a minimum of 20% of the total length of the entire wall. b) Vertical articulations or elevation changes are required on all walls and should be designed to screen rooftop equipment. Rev. 6-5-2015 5 (1) The height of the articulation or elevation change shall be a minimum of two feet (2’). Articulations or elevation changes can be of varying depth as long as the minimum two feet (2’) is met. (2) The length of the new plane created by the articulation or elevation change shall be a minimum of 20% of the total length of the entire wall. 4. Roof Treatments Façade articulations shall provide for vertical and horizontal screening of air conditioning units and all mechanical equipment located on rooftops. The minimum height of the screening shall be equal to the height of the tallest rooftop equipment. G. Single- Family Residential 1. Exterior Building Materials Buildings must comply with the following: a) At least 80% of the entire building façade (excluding windows and doors) shall be finished in one or more of the following materials: • Brick • Stone • Faux brick or stone • Tile • Concrete tiltwall • Stucco • Cementatious Fiberboard Rev. 6-5-2015 6 PLANNING AND ZONING COMMISSION MEETING: June 24, 2015 Agenda Item 6A TO: Planning and Zoning Commission PREPARED BY: Bryce Cox, Planner CASE: PC2015-015 Rhine Valley Subdivision Unit 2– Preliminary Plat SUBJECT: Consider and act upon a request for approval of a preliminary plat of Rhine Valley Unit 2, an approximately 16 acre tract of land situated in the Miles S. Bennett Survey No. 75, Abstract No. 61, County Block 5057, the Julian Diaz Survey No. 66, Abstract No. 187, County Block 5059, and the William Bracken Survey No. 74, Abstract No. 43, County Block 5056, City of Schertz, Bexar County, Texas, generally located on Lower Seguin Road 3,000 feet east of the intersection of Lower Seguin Road and FM 1518. GENERAL INFORMATION: Owner/Applicant: Fred Development, LLC, Gordon Hartman Project Engineer: KFW Engineers, George Weron, P.E. APPLICATION SUBMITTAL DATE: April 13, 2015 June 1, 2015 June 15, 2015 (Original Application) (Revised Submittal) (Revised Submittal) ITEM SUMMARY: The applicant is proposing to preliminary plat approximately 16 acres of land establishing 70 single family residential lots. Forty-seven (47) of the lots in this unit will be SF 50 lots with a minimum size of 6,000 square feet and the remaining twenty three (23) lots will be SF 45 with a minimum size of 5,400 square feet as dictated by the Rhine Valley PDD (Ordinance 13-S-37). Typical Lot Dimensions Code Area Square Feet “SF 45” 5,400 “SF 50” 6,000 Width (ft.) 45 50 Depth (ft.) 120 120 The site is zoned Planned Development District (PDD). This final plat was reviewed using the Rhine Valley PDD (Ordinance 13-S-37) and the UDC, Ordinance 11-S-15, as amended. GENERAL LOCATION AND SITE DESCRIPTION: The subject property is currently undeveloped and generally located on Lower Seguin Road 3,000 feet east of the intersection of Lower Seguin Road and FM 1518. ACCESS AND CIRCULATION: The UDC, Article 14, requires that all residential subdivisions have a minimum of two (2) locations accessing existing public streets. This development is designed to have two (2) points of access via Lower Seguin Road and Saverne Way which was constructed with Unit 1. TREE MITIGATION AND PRESERVATION: The applicant will be responsible for complying with Unified Development Code (UDC), Section 21.9.9 Tree Preservation and Mitigation. The applicant has submitted a tree affidavit which indicates that this site has not protected or heritage trees. The tree affidavit has been verified by the Parks and Community Services department. PARKS: A five (5) acre public park was dedicated with Unit 1 of this subdivision which meets the parkland dedication requirements for this subdivision. The parkland improvements are being constructed in two (2) phases. Phase I of the improvements is currently under construction and includes a parking lot, gazebo, BBQ pits and playground. Phase II of the improvements will be constructed prior to recording the final plat for the next unit and will include soccer fields and multi-purpose ball fields, a sports court and walking trail. PUBLIC SERVICES: The site is serviced by Schertz water and sewer, CPS, AT&T, and Time Warner Cable. PUBLIC IMPROVEMENTS: All public improvements required for this subdivision are required to be installed prior to recording of the final plat per UDC, Section 21.4.15., unless otherwise specified in an approved development agreement. The civil construction plans must be reviewed and approved by the Public Works and Engineering Departments prior to approval of the final plat. Water and Sewer: This site will be serviced through 8” water lines and 8” sewer lines that will be extended throughout the subdivision and stubbed for future development. Drainage: The applicant is responsible for all drainage associated with the subject property, and for compliance with the Storm Water regulations. A preliminary drainage report has been reviewed and approved by the City Engineer. Sidewalks, Hike and Bike Trails: Sidewalks will be constructed along Lower Seguin Road and on both sides of the street throughout the subdivision. All sidewalks are designed to meet the City of Schertz specifications. Additional Design Criteria: The subject property is affected by the additional design requirements imposed by the PDD Design Standards along Lower Seguin Road to include landscaping buffers and screening. A 6’ masonry fence will be constructed along Lower Seguin Road prior to recording the final plat. Road Improvements: All streets will be developed to City of Schertz specifications. Construction plans for all public improvements will be submitted and approved by Public Works and Engineering prior to approval of the final plat. STAFF ANALYSIS AND RECOMMENDATION: The preliminary plat is consistent with applicable requirements for the property, ordinances and regulations. It has been reviewed with no objections by the City Engineer, Public Works, Parks, Inspections, and Fire. Staff recommends approval. 2 Planning Department Recommendation X Approve as submitted Approve with conditions* Denial * While the Commission can impose conditions; conditions should only be imposed to meet requirements of the UDC. COMMISSIONERS CRITERIA FOR CONSIDERATION: The Planning and Zoning Commission is the final approval authority of the proposed preliminary plat. In considering final action on a preliminary plat, the Commission should consider the criteria within UDC, Section 21.12.8 D. Attachments: Aerial (Maps) Exhibit 3 WA DR 26 ! P ! P ST 07 V 6" [ Ú PE HD ! P C PV 8" R SD 26 121 993 7 12198 63 1219945 FRED DEVELOPMENT LLC ! P 1219865 ! P 6 121986 3 121989 7 121986 8 121986 1219883 1219902 1219876 1219882 1219946 FRED DEVELOPMENT LLC n U S E D S 14 310030 LINDORFER, JANICE S & ROBERT C JR T 1219942 ' 60 sio n a xpU er w (Lo ) SE VESOUL VLY 1219947 O OP PR 1219938 LLC ELOPMENT EV D FRED OP PR T 4S D0 E OS SAVERNE WAY U ! P 1219946 FRED DEVELOPMENT LLC uin g e ad o R L RET GA 027 MAR 310 JR & S RLO 8" PVC SDR 26 1219891 1219879 U D 1219890 1219946 FRED DEVELOPMENT LLC D SE CA ! P 1219878 LOWER SEGUIN R 1219889 1219880 U U U O OP R P A, RZ GA ! P 1219887 1219888 1219881 1219877 43 3098 ARLENE H OM C Y RANS ND LARR A 1219903 ! P 1219886 ! P 1219884 1219901 1219875 RX 019 MA 310 REN A R, K 1219885 T S 03 LLC 6 94 ENT 19 12 LOPM E EV 1219900 1219874 E CH FIS 1219899 D ED FR U 1219898 T 309842 SCHNEIDER ALTON B AND EILEEN 6 121989 5S D0 ! P 1219872 1219873 GOODENO 1219897 1219871 BARR WAY 5 121989 SE 70 12198 1219941 FRED DEVELOPMENT LLC O OP PR 69 12198 4 121989 R USE D LLEY ES VA ARCH THA ROU 2 121989 U O MULH U DR S 1219940 FRED DEVELOPMENT LLC 121986 4 ! P U D R 310011 FISCHER DONNIE K & CINDY A U ! P ! P ! P 309811 FRIESENHAHN MILTON AND BILLIE PROPOSED 01 ST N Y LE AL SELESTAT PT Y WA I TE S ER Y WA G UR R ! P N UI EG 1103266 FRED DEVELOPMENT LLC ! P BO TD ER W ! P ! P ! P T S 08 N TIA SA AL S RA ST ET U G IN N BE S PO O PR ! P ! P U U Y VL ED ! P 8" P VC S RE M ! P ED OS OP PR ILL Y U U U 310004 FAIRLEY, GARY R ARE ALV 310024 FLUITT SUE N 5 P OR 121 109 ALVAD ZS 310025 ASHER DORIS L/E ASHER M & HARMAN L S 310002 REYES, MARK M 310031 RITTIMAN, JOY LEE 310005 BARSNESS, DARREN AND SANDY 4 RHINE VALLEY SUBDIVISION UNIT 2 <all other values> 60' Expansion 86' Expansion 120' Expansion Abandon 1" 6" 18" Schertz Gravity Neighboring Gravity U Hydrant Highways 60' Proposed 86' Proposed 120' Proposed Other Cities 2" 8" 20" Schertz Pressure Private Pressure ! P Manholes Major Roads 60' Extension 86' Extension 120' Extension Future TXDOT 3" 10" 24" Highway 4" 12" 30" 16" 36" Minor Roads 1 Inch = 200 Feet 200' Buffer 0 100 200 400 600 800 Feet LIMIT S Z RT S HE IT SC Y LIM T CI LEGEND Y CIT R. ER T Z E Y SC H RA RB CO NOTES: KEY NOTES D TT SITE R WE IN GU SE LO TZ ER TY CI RD F.I.R. = FOUND 1/2" IRON ROD S.I.R. = SET 1/2" IRON ROD WITH BLUE CAP STAMPED "KFW SURVEYING" R.O.W. = ITS LIM 10' G.E.T.TV. EASEMENT 2 15' DRAINAGE EASEMENT 3 VARIABLE WIDTH R.O.W DEDICATION TO CITY OF SHERTZ (0.0268 AC.) 4 VARIABLE WIDTH LANDSCAPE EASEMENT 40' DRAINAGE, AND G.E.T.TV.E. EASEMENT (VOL. 9677, PGS. 166-170) 40' DRAINAGE EASEMENT (VOL. 9677, PGS. 166-170) 10' G.E.T.TV. EASEMENT (VOL. 16923, PG. 1548) FM ESMT = EASEMENT O.P.R. = OFFICIAL PUBLIC RECORDS 5 VARIABLE WIDTH LANDSCAPE & G.E.T.TV. EASEMENT GAS, ELECTRIC, TELEPHONE, CABLE T.V., EASEMENT 6 VARIABLE WIDTH CLEAR VISION EASEMENT 7 10' CLEAR VISION EASEMENT 8 5' WALL MAINTENANCE EASEMENT G.E.T.TV.E. = H SC RIGHT-OF-WAY 1 B. S. L. = 5' G.E.T.TV. EASEMENT (VOL. 16923, PG. 1548) 20' REAR SETBACK 20' REAR SETBACK 5' SIDE SETBACK (15' SIDE SETBACK ADJACENT TO STREET R.O.W.) 5' SIDE SETBACK (15' SIDE SETBACK ADJACENT TO STREET R.O.W.) 5' SIDE SETBACK (15' SIDE SETBACK ADJACENT TO STREET R.O.W.) 1. NO STRUCTURE, FENCES, WALLS OR OTHER OBSTRUCTIONS THAT IMPEDE DRAINAGE SHALL BE PLACED WITHIN THE LIMITS OF THE DRAINAGE EASEMENTS SHOWN ON THIS PLAT. NO LANDSCAPING OR OTHER TYPE OF MODIFICATIONS, WHICH ALTER THE CROSS-SECTIONS OF THE DRAINAGE EASEMENTS, AS APPROVED, SHALL BE ALLOWED WITHOUT THE APPROVAL OF THE DIRECTOR OF PUBLIC WORKS. THE CITY OF SCHERTZ SHALL HAVE THE RIGHT OF INGRESS AND EGRESS OVER GRANTOR'S ADJACENT PROPERTY TO REMOVE ANY IMPEDING OBSTRUCTIONS PLACED WITHIN THE LIMITS OF SAID DRAINAGE EASEMENTS AND TO MAKE ANY MODIFICATIONS OR IMPROVEMENTS WITHIN SAID DRAINAGE EASEMENTS. ALL SAID DRAINAGE EASEMENTS WITHIN SAID LOTS SHALL BE PRIVATELY MAINTAINED BY PROPERTY OWNERS. 2. SELLING A PORTION OF THIS ADDITION BY METES AND BOUNDS IS A VIOLATION OF CITY ORDINANCE AND STATE LAW AND IS SUBJECT TO FINES AND WITHHOLDING OF UTILITIES AND BUILDING PERMITS. 3. ALL OPEN SPACE, COMMON AREAS, GREENBELTS, DRAINAGE EASEMENTS OR OTHER AREAS IDENTIFIED AS PRIVATE SHALL BE THE RESPONSIBILITY OF THE OWNER OR OWNERS SUCCESSORS AND / OR ASSIGNS. 5' SIDE SETBACK (15' SIDE SETBACK ADJACENT TO STREET R.O.W.) 120' TYP. 120' TYP. 25' FRONT BUILDING SETBACK 20' FRONT BUILDING SETBACK BUILDING SETBACK LINE 15 18 50' TYP. 9 16' SANITARY SEWER EASEMENT NOT TO SCALE NOT TO SCALE N.T.S. 10' ELEC., GAS, TELE., & CA. T.V. EASEMENT 45' TYP. 10' ELEC., GAS, TELE., & CA. T.V. EASEMENT 4. TWO POINTS OF ACCESS SHALL BE MAINTAINED AT ALL TIMES. 5. THIS PLAT CONSISTS OF 70 BUILDABLE LOTS, 47 SF 50 LOTS AND 23 SF 45 LOTS. 6. ACCORDING TO FEMA FLOOD INSURANCE RATE MAP 315 OF 785, COMMUNITY PANEL NO. 48029C0315F, DATED SEPTEMBER 29, 2010. THE SUBJECT PROPERTY IS NOT WITHIN THE 100-YR FLOODPLAIN. 7. LANDSCAPE AND WALL EASEMENTS WILL BE MAINTAINED AND IRRIGATED BY THE HOME OWNERS ASSOCIATION. 8. LOT 2, BLOCK 16; LOT 7, BLOCK 13; LOT 17, BLOCK 13; LOT 1, BLOCK 22; LOT 13, BLOCK 21 ARE THE RESPONSIBILITY OF THE DEVELOPER OR ITS SUCCESSORS AND/OR ASSIGNS. 9. PROPERTY BEING PLATTED IS CURRENTLY ZONED PDD. 10. THE THOROUGHFARE ALIGNMENTS SHOWN ON THIS EXHIBIT ARE FOR ILLUSTRATION PURPOSES AND DO NOT SET THE ALIGNMENT. ALIGNMENT IS DETERMINED AT TIME OF FINAL PLAT. 11. ALL LOTS ARE TO BE UTILITY SERVICED FROM THE FRONT OF THE LOTS ADJACENT TO THE STREET. 12. WALL MAINTENANCE EASEMENT WILL BE MAINTAINED BY THE HOMEOWNER'S ASSOCIATION. THE PLACEMENT OF OBSTRUCTIONS, FENCES AND/OR PERMANENT STRUCTURES BY THE LOT OWNER SHALL BE PROHIBITED WITHIN SAID EASEMENT. SURVEYOR NOTES: 1. 1/2" DIAMETER REBAR WITH A BLUE PLASTIC CAP STAMPED "KFW SURVEYING" SET AT ALL CORNERS UNLESS NOTED OTHERWISE. 2. BEARINGS ARE BASED ON THE STATE PLANE COORDINATE SYSTEM ESTABLISHED FOR THE TEXAS SOUTH CENTRAL ZONE, NORTH AMERICAN DATUM (NAD) OF 1983. 3. THE COORDINATES SHOWN HEREON ARE GRID WITH A COMBINED SCALE FACTOR OF 1.00017. 4. REFERENCED PROPERTY IS IN ZONE X, AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANUAL CHANCE FLOODPLAIN AS SCALED FROM FEMA FLOOD MAP 315 OF 785, COMMUNITY PANEL NO. 48029C0315F, DATED SEPTEMBER 29, 2010. 5. THE ELEVATIONS FOR THIS SURVEY ARE BASED ON NAVD88 (GEOID09). GRID: N= 13739164.40 E= 2211014.57 EXIST. 14' G.E.T.TV.E. 0' C.P.S. NOTES: 5. ROOF OVERHANGS ARE ALLOWED WITHIN FIVE (5) FOOT WIDE ELECTRIC AND GAS EASEMENTS WHEN ONLY UNDERGROUND ELECTRIC AND GAS FACILITIES ARE PROPOSED OR EXISTING WITHIN THOSE FIVE (5) FOOT WIDE EASEMENTS. CLEAR VISION EASEMENTS MUST BE FREE OF VISUAL OBSTRUCTIONS (E.G. STRUCTURES, WALLS, FENCES, AND VEGETATION), WHICH ARE HIGHER THAN THREE (3) FEET AND LOWER THAN EIGHT (8) FEET ABOVE THE PAVEMENT AS PER THE AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (ASSHTO) POLICY ON GEOMETRIC DESIGN OF HIGHWAYS AND STREETS, OR LATEST REVISION THEREOF. 'L DR AND AI SC NA A GE PE EA BU SE FF ME ER NT _________________________________________________________. AGENT FOR CIBOLO CREEK MUNICIPAL AUTHORITY I, THE UNDERSIGNED, CITY ENGINEER OF THE CITY OF SCHERTZ, TEXAS HEREBY CERTIFY THAT THIS SUBDIVISION PLAT CONFORMS TO ALL REQUIREMENTS OF THE SUBDIVISION REGULATIONS OF THE CITY AS TO WHICH THIS APPROVAL IS REQUIRED. . 30 THIS PLAT DOES NOT AMEND, ALTER, RELEASE OR OTHERWISE AFFECT ANY EXISTING ELECTRIC, GAS, WATER, SEWER, DRAINAGE, TELEPHONE, CABLE EASEMENTS OR ANY OTHER EASEMENTS FOR UTILITIES UNLESS THE CHANGES TO SUCH EASEMENTS ARE DESCRIBED BELOW: CONCRETE DRIVEWAY APPROACHES AND STEPS ARE ALLOWED WITHIN THE FIVE (5) FOOT WIDE ELECTRIC AND GAS EASEMENTS WHEN LOTS ARE SERVED ONLY BY REAR LOT UNDERGROUND ELECTRIC AND GAS FACILITIES. 200' THIS PROPOSED DEVELOPMENT HAS BEEN REVIEWED AND APPROVED BY THE CIBOLO CREEK MUNCIPAL AUTHORITY (C.C.M.A.) FOR WASTEWATER TREATMENT PLANT CAPACITY AND EASEMENTS. ALL FEES DUE FOR IMPACT TO THE SYSTEM AT THE TIME OF CONNECTION WILL BE CALCULATED AT SUBMITTAL OF BUILDING PERMIT APPLICATION. ANY CPS MONETARY LOSS RESULTING FROM MODIFICATIONS REQUIRED OF CPS EQUIPMENT, LOCATED WITHIN SAID EASEMENT, DUE TO GRADE CHANGES OR GROUND ELEVATION ALTERATIONS SHALL BE CHARGED TO THE PERSON OR PERSONS DEEMED RESPONSIBLE FOR SAID GRADE CHANGES OR GROUND ELEVATION ALTERATION. 4. 150' CLEAR VISION NOTE: & 3. EXISTING 8" WATER LI NE EXISTING 8" SEWER LI NE CITY PUBLIC SERVICE BOARD IS HEREBY DEDICATED THE EASEMENTS AND RIGHTS-OF-WAY FOR ELECTRIC AND GAS DISTRIBUTION AND SERVICE FACILITIES IN THE AREAS DESIGNATED ON THIS PLAT AS "ELECTRIC EASEMENT," "GAS EASEMENT," "ANCHOR EASEMENT," "SERVICE EASEMENT," "OVERHANG EASEMENT," "UTILITY EASEMENT," AND "TRANSFORMER EASEMENT" FOR THE PURPOSE OF INSTALLING, CONSTRUCTING, RECONSTRUCTING, MAINTAINING, REMOVING, INSPECTING, PATROLLING, AND ERECTING POLES, HANGING OR BURYING WIRES, CABLES, CONDUITS, PIPELINES OR TRANSFORMERS, EACH WITH ITS NECESSARY APPURTENANCES TOGETHER WITH THE RIGHT OF INGRESS AND EGRESS OVER GRANTOR'S ADJACENT LAND, THE RIGHT TO RELOCATE SAID FACILITIES WITHIN SAID EASEMENT AND RIGHT-OF-WAY AREAS, AND THE RIGHT TO REMOVE FROM SAID LANDS ALL TREES OR PARTS THEREOF, OR OTHER OBSTRUCTIONS WHICH ENDANGER OR MAY INTERFERE WITH THE EFFICIENCY OF SAID LINES OR APPURTENANCES THERETO. IT IS AGREED AND UNDERSTOOD THAT NO BUILDINGS, CONCRETE SLABS, OR WALLS WILL BE PLACED WITHIN SAID EASEMENT AREA. CH A 12 EL 15 60 AS .00 (V S 6 LO HER AC OL CH W & R . E E L ES ZO 1603 RTZ R S IND E A , NI 5, NG PG TX GUI HA 7 N R : R . 9 81 -A 20 54 RD MAN & O. DV P. L R.) 2. 100' CITY ENGINEER MI 1. 50' THIS PLAT OF THE HAS BEEN SUBMITTED TO AND CONSIDERED BY THE CITY PLANNING AND ZONING COMMISSION OF THE CITY OF SCHERTZ, TEXAS AND IS HEREBY APPROVED BY SUCH COMMISSION. 14' G.E.T.TV.E. COUNTY OF BEXAR DATED THIS THIS THE _________ DAY OF __________. _____________________________________. OWNER: FRED DEVELOPMENT, LLC. 1202 W. BITTERS, BLDG 1 SUITE 1200 SAN ANTONIO, TX 78216 PHONE: 210-490-1798 FAX: 210-493-2811 GIVEN UNDER MY HAND AND SEAL OF OFFICE THIS A..D. ______. DAY OF ____________ . LOT 7, BLOCK 13 PRIVATE OPEN SPACE AND VARIABLE WIDTH DRAINAGE EASEMENT . BY: . SECRETARY STATE OF TEXAS COUNTY OF BEXAR I, COUNTY CLERK OF SAID COUNTY, DO HEREBY CERTIFY THAT THIS PLAT WAS FILED FOR RECORD IN MY OFFICE, ON THE 14' G.E.T.TV.E. DAY OF RECORDED THE A.D. AT DAY OF A.D. BEXAR COUNTY IN BOOK/VOLUME M. AND DULY AT M. IN THE RECORDS OF PAGE . IN TESTIMONY WHEREOF, WITNESS MY HAND AND OFFICIAL SEAL OF OFFICE, THIS DAY OF A.D. . COUNTY CLERK, BEXAR COUNTY,TEXAS BY: , DEPUTY BEXAR COUNTY TEXAS DETAIL "B" SEE PAGE 2 OF 2 STATE OF TEXAS COUNTY OF BEXAR I THE UNDERSIGNED, A REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF TEXAS, HEREBY CERTIFY THAT PROPER ENGINEERING CONSIDERATION HAS BEEN GIVEN TO THIS PLAT. . REGISTERED PROFESSIONAL ENGINEER _______________________, P.E. KFW ENGINEERS STATE OF TEXAS COUNTY OF BEXAR I HEREBY CERTIFY THAT THE ABOVE PLAT CONFORMS TO THE MINIMUM STANDARDS SET FORTH BY THE TEXAS BOARD OF PROFESSIONAL LAND SURVEYING ACCORDING TO AN ACTUAL SURVEY MADE ON THE GROUND. . TERESA A. SEIDEL REGISTERED PROFESSIONAL LAND SURVEYOR NO. 5672 KFW SURVEYING, LLC 14603 HUEBNER RD. BLDG. 40 SAN ANTONIO, TEXAS 78230 PHONE: 210-979-8444 FAX: 210-979-8441 FIRM LICENSE NO. 10122300 19.50 ACRES JOY LEE RITTIMAN 12740 LOWER SEGUIN RD SCHERTZ, TX 78154 R.) (VOL. 15243, PG. 1106 D.P. ZONING: R-A & DVL NOTARY PUBLIC . CHAIRPERSON 19.47 ACRES SUE N. FLUITT 12610 LOWER SEGUIN RD SCHERTZ, TX 78154 (VOL. 8472, PG. 1941 D.P.R.) ZONING: R-A & DVL BEFORE ME, THE UNDERSIGNED AUTHORITY ON THIS DAY PERSONALLY APPEARED , KNOWN TO ME TO BE THE PERSON WHOSE NAME IS SUBSCRIBED TO THE FOREGOING INSTRUMENT, AND ACKNOWLEDGED TO ME THAT HE EXECUTED THE SAME FOR THE PURPOSES AND CONSIDERATIONS THEREIN EXPRESSED AND IN THE CAPACITY THEREIN STATED. A.D. 20 BY: DETAIL "A" SEE PAGE 2 OF 2 STATE OF TEXAS COUNTY OF BEXAR DAY OF VARIABLE WIDTH WATER TRANSMISSION LINE AND RIGHT-OF-WAY EASEMENT (VOL. 9899 PG. 559) 2.00 ACRES SALVADOR P. ALVAREZ 12610 LOWER SEGUIN RD SCHERTZ, TX 78154 (VOL. 12023, PG. 647 D.P.R.) ZONING: R-A & PRE I, (WE) THE OWNER(S) OF THE LAND SHOWN ON THIS PLAT, AND DESIGNATED HEREIN AS THE RHINE VALLEY SUBDIVISION UNIT 2 OF SCHERTZ, TEXAS AND WHOSE NAME IS SUBSCRIBED HERETO, HEREBY DEDICATE FOR THE USE OF THE PUBLIC FOREVER ALL STREETS, ALLEYS, PARKS, WATER COURSES, DRAINS, EASEMENTS, AND PUBLIC PLACES THEREON SHOWN FOR THE PURPOSE AND CONSIDERATION THEREIN EXPRESSED. RHINE VALLEY SUBDIVISION UNIT 2 A 15.2988 ACRE TRACT OF LAND IN THE CITY OF SCHERTZ, BEXAR COUNTY, TEXAS OUT OF THE MILES S. BENNETT SURVEY NO. 75, ABSTRACT NO. 61, COUNTY BLOCK 5057, THE JULIAN DIAZ SURVEY NO. 66, ABSTRACT NO. 187, COUNTY BLOCK 5059 AND THE WILLIAM BRACKEN SURVEY NO. 74, ABSTRACT NO. 43, COUNTY BLOCK 5056, BEXAR COUNTY, TEXAS AND BEING OUT OF A 137.51 ACRE TRACT OF LAND CONVEYED TO FRED DEVELOPMENT, LLC OF RECORD IN VOLUME 15711 PAGE 1407 OF THE OFFICIAL PUBLIC RECORDS OF BEXAR COUNTY, TEXAS. 14' G.E.T.TV.E. 30' LANDSCAPE BUFFER & DRAINAGE EASEMENT VARIABLE WIDTH WATER TRANSMISSION LINE AND RIGHT-OF-WAY EASEMENT (VOL. 9899 PG. 559) REMAINDER OF 110.58 ACRES MILTON & BILLIE FRIESENHAHN (VOL. 15867, PGS. 1756 O.P.R.) ZONING: R-A & DVL GRID: N= 13740091.50 E= 2211891.96 Date: Jun 15, 2015, 12:13pm User ID: HHernandez File: P:\205\14\08\Design\Civil\Plat\PL2051408-PRELIM.dwg LIMIT S Z RT S HE IT SC Y LIM T CI LEGEND R. ER T Z Y CIT TD Y SC H RA R CO NOTES: KEY NOTES T BE SITE R WE IN GU SE LO TZ ER TY CI RD 2 15' DRAINAGE EASEMENT S.I.R. = SET 1/2" IRON ROD WITH BLUE CAP STAMPED "KFW SURVEYING" 3 VARIABLE WIDTH R.O.W DEDICATION TO CITY OF SHERTZ (0.0268 AC.) RIGHT-OF-WAY 4 VARIABLE WIDTH LANDSCAPE EASEMENT 40' DRAINAGE, AND G.E.T.TV.E. EASEMENT (VOL. 9677, PGS. 166-170) 40' DRAINAGE EASEMENT (VOL. 9677, PGS. 166-170) FM ESMT = EASEMENT O.P.R. = OFFICIAL PUBLIC RECORDS 5 VARIABLE WIDTH LANDSCAPE & G.E.T.TV. EASEMENT GAS, ELECTRIC, TELEPHONE, CABLE T.V., EASEMENT 6 VARIABLE WIDTH CLEAR VISION EASEMENT 7 10' CLEAR VISION EASEMENT 8 5' WALL MAINTENANCE EASEMENT B. S. L. = 1. NO STRUCTURE, FENCES, WALLS OR OTHER OBSTRUCTIONS THAT IMPEDE DRAINAGE SHALL BE PLACED WITHIN THE LIMITS OF THE DRAINAGE EASEMENTS SHOWN ON THIS PLAT. NO LANDSCAPING OR OTHER TYPE OF MODIFICATIONS, WHICH ALTER THE CROSS-SECTIONS OF THE DRAINAGE EASEMENTS, AS APPROVED, SHALL BE ALLOWED WITHOUT THE APPROVAL OF THE DIRECTOR OF PUBLIC WORKS. THE CITY OF SCHERTZ SHALL HAVE THE RIGHT OF INGRESS AND EGRESS OVER GRANTOR'S ADJACENT PROPERTY TO REMOVE ANY IMPEDING OBSTRUCTIONS PLACED WITHIN THE LIMITS OF SAID DRAINAGE EASEMENTS AND TO MAKE ANY MODIFICATIONS OR IMPROVEMENTS WITHIN SAID DRAINAGE EASEMENTS. ALL SAID DRAINAGE EASEMENTS WITHIN SAID LOTS SHALL BE PRIVATELY MAINTAINED BY PROPERTY OWNERS. 2. SELLING A PORTION OF THIS ADDITION BY METES AND BOUNDS IS A VIOLATION OF CITY ORDINANCE AND STATE LAW AND IS SUBJECT TO FINES AND WITHHOLDING OF UTILITIES AND BUILDING PERMITS. 3. ALL OPEN SPACE, COMMON AREAS, GREENBELTS, DRAINAGE EASEMENTS OR OTHER AREAS IDENTIFIED AS PRIVATE SHALL BE THE RESPONSIBILITY OF THE OWNER OR OWNERS SUCCESSORS AND / OR ASSIGNS. 10' G.E.T.TV. EASEMENT (VOL. 16923, PG. 1548) FOUND 1/2" IRON ROD G.E.T.TV.E. = H SC 10' G.E.T.TV. EASEMENT F.I.R. = R.O.W. = ITS LIM 1 5' G.E.T.TV. EASEMENT (VOL. 16923, PG. 1548) BUILDING SETBACK LINE 18 15 9 4. TWO POINTS OF ACCESS SHALL BE MAINTAINED AT ALL TIMES. 5. THIS PLAT CONSISTS OF 70 BUILDABLE LOTS, 47 SF 50 LOTS AND 23 SF 45 LOTS. 6. ACCORDING TO FEMA FLOOD INSURANCE RATE MAP 315 OF 785, COMMUNITY PANEL NO. 48029C0315F, DATED SEPTEMBER 29, 2010. THE SUBJECT PROPERTY IS NOT WITHIN THE 100-YR FLOODPLAIN. 7. LANDSCAPE AND WALL EASEMENTS WILL BE MAINTAINED AND IRRIGATED BY THE HOME OWNERS ASSOCIATION. 8. LOT 2, BLOCK 16; LOT 7, BLOCK 13; LOT 17, BLOCK 13; LOT 1, BLOCK 22; LOT 13, BLOCK 21 ARE THE RESPONSIBILITY OF THE DEVELOPER OR ITS SUCCESSORS AND/OR ASSIGNS. 9. PROPERTY BEING PLATTED IS CURRENTLY ZONED PDD. 10. THE THOROUGHFARE ALIGNMENTS SHOWN ON THIS EXHIBIT ARE FOR ILLUSTRATION PURPOSES AND DO NOT SET THE ALIGNMENT. ALIGNMENT IS DETERMINED AT TIME OF FINAL PLAT. 11. ALL LOTS ARE TO BE UTILITY SERVICED FROM THE FRONT OF THE LOTS ADJACENT TO THE STREET. 12. WALL MAINTENANCE EASEMENT WILL BE MAINTAINED BY THE HOMEOWNER'S ASSOCIATION. THE PLACEMENT OF OBSTRUCTIONS, FENCES AND/OR PERMANENT STRUCTURES BY THE LOT OWNER SHALL BE PROHIBITED WITHIN SAID EASEMENT. 16' SANITARY SEWER EASEMENT THE COORDINATES SHOWN HEREON ARE GRID WITH A COMBINED SCALE FACTOR OF 1.00017. 4. REFERENCED PROPERTY IS IN ZONE X, AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANUAL CHANCE FLOODPLAIN AS SCALED FROM FEMA FLOOD MAP 315 OF 785, COMMUNITY PANEL NO. 48029C0315F, DATED SEPTEMBER 29, 2010. LOT 13 BLK 23 LOT 12 BLK 23 CE T VIN 1 S BEARINGS ARE BASED ON THE STATE PLANE COORDINATE SYSTEM ESTABLISHED FOR THE TEXAS SOUTH CENTRAL ZONE, NORTH AMERICAN DATUM (NAD) OF 1983. 3. 5. 30' LANDSCAPE BUFFER AND DRAINAGE EASEMENT LOT 11 BLK 23 4 8 VARIABLE WIDTH LANDSCAPE AND DRAINAGE EASEMENT LOT 2 BLK 16 L7 2. 1/2" DIAMETER REBAR WITH A BLUE PLASTIC CAP STAMPED "KFW SURVEYING" SET AT ALL CORNERS UNLESS NOTED OTHERWISE. LOT 2, BLK 16 13 .78 ' 1. .S.L. 15' B LOT 10 BLK 23 SURVEYOR NOTES: A NT W Y N.T.S. 23.8 THE ELEVATIONS FOR THIS SURVEY ARE BASED ON NAVD88 (GEOID09). S.I.R. 6' .46'' 56 14' G.E.T.TV.E. C.P.S. NOTES: 4. CONCRETE DRIVEWAY APPROACHES AND STEPS ARE ALLOWED WITHIN THE FIVE (5) FOOT WIDE ELECTRIC AND GAS EASEMENTS WHEN LOTS ARE SERVED ONLY BY REAR LOT UNDERGROUND ELECTRIC AND GAS FACILITIES. 5. ROOF OVERHANGS ARE ALLOWED WITHIN FIVE (5) FOOT WIDE ELECTRIC AND GAS EASEMENTS WHEN ONLY UNDERGROUND ELECTRIC AND GAS FACILITIES ARE PROPOSED OR EXISTING WITHIN THOSE FIVE (5) FOOT WIDE EASEMENTS. ENT ST. VINC 4 VARIABLE WIDTH WATER TRANSMISSION LINE AND RIGHT-OF-WAY EASEMENT (VOL. 9899 PG. 559) . 15' B.S.L LOT 1 BLK 20 LOT 1 BLK 22 THIS PLAT DOES NOT AMEND, ALTER, RELEASE OR OTHERWISE AFFECT ANY EXISTING ELECTRIC, GAS, WATER, SEWER, DRAINAGE, TELEPHONE, CABLE EASEMENTS OR ANY OTHER EASEMENTS FOR UTILITIES UNLESS THE CHANGES TO SUCH EASEMENTS ARE DESCRIBED BELOW: F.I.R. AD LOW IN RO EGU ER S CLEAR VISION NOTE: CLEAR VISION EASEMENTS MUST BE FREE OF VISUAL OBSTRUCTIONS (E.G. STRUCTURES, WALLS, FENCES, AND VEGETATION), WHICH ARE HIGHER THAN THREE (3) FEET AND LOWER THAN EIGHT (8) FEET ABOVE THE PAVEMENT AS PER THE AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (ASSHTO) POLICY ON GEOMETRIC DESIGN OF HIGHWAYS AND STREETS, OR LATEST REVISION THEREOF. THIS PROPOSED DEVELOPMENT HAS BEEN REVIEWED AND APPROVED BY THE CIBOLO CREEK MUNCIPAL AUTHORITY (C.C.M.A.) FOR WASTEWATER TREATMENT PLANT CAPACITY AND EASEMENTS. ALL FEES DUE FOR IMPACT TO THE SYSTEM AT THE TIME OF CONNECTION WILL BE CALCULATED AT SUBMITTAL OF BUILDING PERMIT APPLICATION. ROAD 3. ANY CPS MONETARY LOSS RESULTING FROM MODIFICATIONS REQUIRED OF CPS EQUIPMENT, LOCATED WITHIN SAID EASEMENT, DUE TO GRADE CHANGES OR GROUND ELEVATION ALTERATIONS SHALL BE CHARGED TO THE PERSON OR PERSONS DEEMED RESPONSIBLE FOR SAID GRADE CHANGES OR GROUND ELEVATION ALTERATION. S.I.R. 6 3 SEGUIN 2. CITY PUBLIC SERVICE BOARD IS HEREBY DEDICATED THE EASEMENTS AND RIGHTS-OF-WAY FOR ELECTRIC AND GAS DISTRIBUTION AND SERVICE FACILITIES IN THE AREAS DESIGNATED ON THIS PLAT AS "ELECTRIC EASEMENT," "GAS EASEMENT," "ANCHOR EASEMENT," "SERVICE EASEMENT," "OVERHANG EASEMENT," "UTILITY EASEMENT," AND "TRANSFORMER EASEMENT" FOR THE PURPOSE OF INSTALLING, CONSTRUCTING, RECONSTRUCTING, MAINTAINING, REMOVING, INSPECTING, PATROLLING, AND ERECTING POLES, HANGING OR BURYING WIRES, CABLES, CONDUITS, PIPELINES OR TRANSFORMERS, EACH WITH ITS NECESSARY APPURTENANCES TOGETHER WITH THE RIGHT OF INGRESS AND EGRESS OVER GRANTOR'S ADJACENT LAND, THE RIGHT TO RELOCATE SAID FACILITIES WITHIN SAID EASEMENT AND RIGHT-OF-WAY AREAS, AND THE RIGHT TO REMOVE FROM SAID LANDS ALL TREES OR PARTS THEREOF, OR OTHER OBSTRUCTIONS WHICH ENDANGER OR MAY INTERFERE WITH THE EFFICIENCY OF SAID LINES OR APPURTENANCES THERETO. IT IS AGREED AND UNDERSTOOD THAT NO BUILDINGS, CONCRETE SLABS, OR WALLS WILL BE PLACED WITHIN SAID EASEMENT AREA. LOWER 1. S.I.R. VARIABLE WIDTH WATER TRANSMISSION LINE AND RIGHT-OF-WAY EASEMENT (VOL. 9899 PG. 559) 1 WAY DETAIL "A" SCALE: 1" = 50' _________________________________________________________. AGENT FOR CIBOLO CREEK MUNICIPAL AUTHORITY I, THE UNDERSIGNED, CITY ENGINEER OF THE CITY OF SCHERTZ, TEXAS HEREBY CERTIFY THAT THIS SUBDIVISION PLAT CONFORMS TO ALL REQUIREMENTS OF THE SUBDIVISION REGULATIONS OF THE CITY AS TO WHICH THIS APPROVAL IS REQUIRED. . CITY ENGINEER 8 LOT 2 BLK 20 14' G.E.T.TV.E. THIS PLAT OF THE HAS BEEN SUBMITTED TO AND CONSIDERED BY THE CITY PLANNING AND ZONING COMMISSION OF THE CITY OF SCHERTZ, TEXAS AND IS HEREBY APPROVED BY SUCH COMMISSION. COUNTY OF BEXAR I, (WE) THE OWNER(S) OF THE LAND SHOWN ON THIS PLAT, AND DESIGNATED HEREIN AS THE RHINE VALLEY SUBDIVISION UNIT 2 OF SCHERTZ, TEXAS AND WHOSE NAME IS SUBSCRIBED HERETO, HEREBY DEDICATE FOR THE USE OF THE PUBLIC FOREVER ALL STREETS, ALLEYS, PARKS, WATER COURSES, DRAINS, EASEMENTS, AND PUBLIC PLACES THEREON SHOWN FOR THE PURPOSE AND CONSIDERATION THEREIN EXPRESSED. DETAIL "B" DATED THIS DAY OF A.D. 20 . SCALE: 1" = 50' BY: . CHAIRPERSON BY: . SECRETARY THIS THE _________ DAY OF __________. STATE OF TEXAS COUNTY OF BEXAR _____________________________________. OWNER: FRED DEVELOPMENT, LLC. 1202 W. BITTERS, BLDG 1 SUITE 1200 SAN ANTONIO, TX 78216 PHONE: 210-490-1798 FAX: 210-493-2811 I, COUNTY CLERK OF SAID COUNTY, DO HEREBY CERTIFY THAT THIS PLAT WAS FILED FOR RECORD IN MY OFFICE, ON THE DAY OF RECORDED THE STATE OF TEXAS COUNTY OF BEXAR A.D. AT DAY OF A.D. BEXAR COUNTY IN BOOK/VOLUME BEFORE ME, THE UNDERSIGNED AUTHORITY ON THIS DAY PERSONALLY APPEARED , KNOWN TO ME TO BE THE PERSON WHOSE NAME IS SUBSCRIBED TO THE FOREGOING INSTRUMENT, AND ACKNOWLEDGED TO ME THAT HE EXECUTED THE SAME FOR THE PURPOSES AND CONSIDERATIONS THEREIN EXPRESSED AND IN THE CAPACITY THEREIN STATED. GIVEN UNDER MY HAND AND SEAL OF OFFICE THIS A..D. ______. DAY OF ____________ M. AND DULY AT M. IN THE RECORDS OF PAGE . IN TESTIMONY WHEREOF, WITNESS MY HAND AND OFFICIAL SEAL OF OFFICE, THIS DAY OF A.D. . COUNTY CLERK, BEXAR COUNTY,TEXAS BY: , DEPUTY . NOTARY PUBLIC BEXAR COUNTY TEXAS STATE OF TEXAS COUNTY OF BEXAR I THE UNDERSIGNED, A REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF TEXAS, HEREBY CERTIFY THAT PROPER ENGINEERING CONSIDERATION HAS BEEN GIVEN TO THIS PLAT. . REGISTERED PROFESSIONAL ENGINEER _______________________, P.E. KFW ENGINEERS STATE OF TEXAS COUNTY OF BEXAR I HEREBY CERTIFY THAT THE ABOVE PLAT CONFORMS TO THE MINIMUM STANDARDS SET FORTH BY THE TEXAS BOARD OF PROFESSIONAL LAND SURVEYING ACCORDING TO AN ACTUAL SURVEY MADE ON THE GROUND. . TERESA A. SEIDEL REGISTERED PROFESSIONAL LAND SURVEYOR NO. 5672 KFW SURVEYING, LLC 14603 HUEBNER RD. BLDG. 40 SAN ANTONIO, TEXAS 78230 PHONE: 210-979-8444 FAX: 210-979-8441 FIRM LICENSE NO. 10122300 RHINE VALLEY SUBDIVISION UNIT 2 A 15.2988 ACRE TRACT OF LAND IN THE CITY OF SCHERTZ, BEXAR COUNTY, TEXAS OUT OF THE MILES S. BENNETT SURVEY NO. 75, ABSTRACT NO. 61, COUNTY BLOCK 5057, THE JULIAN DIAZ SURVEY NO. 66, ABSTRACT NO. 187, COUNTY BLOCK 5059 AND THE WILLIAM BRACKEN SURVEY NO. 74, ABSTRACT NO. 43, COUNTY BLOCK 5056, BEXAR COUNTY, TEXAS AND BEING OUT OF A 137.51 ACRE TRACT OF LAND CONVEYED TO FRED DEVELOPMENT, LLC OF RECORD IN VOLUME 15711 PAGE 1407 OF THE OFFICIAL PUBLIC RECORDS OF BEXAR COUNTY, TEXAS. Date: Jun 15, 2015, 12:13pm User ID: HHernandez File: P:\205\14\08\Design\Civil\Plat\PL2051408-PRELIM.dwg PLANNING AND ZONING COMMISSION MEETING: June 24, 2015 Agenda Item 6B TO: Planning and Zoning Commission PREPARED BY: Bryce Cox, Planner CASE: PC2015-018 The Reserve at Schertz II, Unit 3 – Preliminary Plat SUBJECT: Consider and act upon a request for approval of a preliminary plat of The Reserve at Schertz II, Unit 3, an approximately 19 acre tract of land situated in the S. B. Lewis Survey No. 317, Abstract No. 443, and the Antonio Zamora Survey No. 36, Abstract No. 82 City of Schertz, Bexar County, Texas, generally located on Graytown Road 1,500 feet south east of the intersection of Boenig Drive and Graytown Road. GENERAL INFORMATION: Owner/Developer/Applicant: Triple H Development, LLC, Harry Hausman, Developer Project Engineer: Briones Engineers, Andy Rodriquez, Project Manager APPLICATION SUBMITTAL DATE: May 11, 2015 June 2, 2015 June 15, 2015 (Original Application) (Revised Submittal) (Revised Submittal) ITEM SUMMARY: The applicant is proposing to preliminary plat approximately 19 acres of land establishing 23 single family residential lots with a minimum lot size of 21,780 square feet and 25’ building setbacks on all sides dictated by the zoning district. The site is zoned Residential Agriculture (RA). GENERAL LOCATION AND SITE DESCRIPTION: The subject property is currently undeveloped and is located on Graytown Road 1,500 feet south east of the intersection of Boenig Drive and Graytown Road, adjacent to The Reserve at Schertz Unit 1. ACCESS AND CIRCULATION: The UDC, Article 14, requires that all residential subdivisions have a minimum of two (2) locations accessing existing public streets. This development is designed to have two (2) points of access via Graytown Road and Ivy Jet which was constructed with Unit 1 of The Reserve at Schertz. TREE MITIGATION AND PRESERVATION: The applicant will be responsible for complying with Unified Development Code (UDC), Section 21.9.9 Tree Preservation and Mitigation. The applicant has submitted a tree affidavit which indicates that this site has not protected or heritage trees. The tree affidavit has been verified by the Parks and Community Services department. PARKS: There is no parkland being proposed with this subdivision. The Parks, Recreation and Community Services Department has determined that a fee-in lieu of parkland dedication in the amount of $1000 per dwelling unit will be paid by the Developer prior to recording of the final plat. This application was reviewed under UDC, Ordinance 11-S-15. PUBLIC SERVICES: The site is serviced by Schertz water, SARA, CPS, AT&T, and Time Warner Cable. PUBLIC IMPROVEMENTS: All public improvements required for this subdivision are required to be installed prior to recording of the final plat of each Unit per UDC, Section 21.4.15., unless otherwise specified in an approved development agreement. The civil construction plans must be reviewed and approved by the Public Works and Engineering Departments prior to approval of the final plat. Water and Sewer: This site is serviced through 8” water lines and 8” sewer lines that will be extended throughout the subdivision and stubbed out for future sewer extension. Sewer service will be provided by the San Antonio River Authority (SARA) who holds the certificate of Convenience and Necessity (CCN) for this site. Water service will be provided by the City of Schertz. Drainage: The applicant is responsible for all drainage associated with the subject property, and for compliance with the Storm Water regulations. A preliminary drainage report has been reviewed and approved by the City Engineer. The subdivision will be providing onsite detention. Sidewalks, Hike and Bike Trails: Sidewalks will be constructed along Graytown Road and on both sides of the street throughout the subdivision. All sidewalks will be designed to meet the City of Schertz specifications. Additional Design Criteria: The subject property is affected by the additional design requirements of the UDC, Section 21.14.3. along Graytown Road to include landscaping buffers and screening. An 8’ masonry screening wall will be constructed along the side of Graytown Road for the length of the subdivision prior to the recording of the final plat. Two landscape buffer lots (Lot 16, Block 15 and Lot 37, Block 18) adjacent to Graytown Road have been provided with this plat. Road Improvements: The streets within the subdivision will be constructed according to City of Schertz specifications. Construction plans for all public improvements will be submitted and approved by Public Works and Engineering prior to approval of the final plat. STAFF ANALYSIS AND RECOMMENDATION: The preliminary plat has been reviewed with no objections by the City Engineer, Public Works, Parks, Inspections, Fire and Police. The plat is consistent with all applicable zoning requirements, ordinances, and regulations. Staff recommends approval of the preliminary plat. Planning Department Recommendation X Approve as submitted Approve with conditions* Denial * While the Commission can impose conditions; conditions should only be imposed to meet requirements of the UDC. COMMISSIONERS CRITERIA FOR CONSIDERATION: The Planning and Zoning Commission is the final approval authority of the proposed preliminary plat. In considering final action on a preliminary plat, the Commission should consider the criteria within UDC, Section 21.12.8 D. Attachments: Aerial (Map) Plat Exhibit R DE UN CT GA GE PA RK OD WO S LE TS U U LA VA NO DO S HT RA N 619193 TRIPLE H DEVELOPMENT LLC U PA RK CO NN U ' 86 LY NS 119 384 9 T ro 'P 60 PO ND 119 386 9 HO RN 11 93 87 0 AY OW LEN 1188101 COSGROVE MATHEW T 619212 SCHUCHERT ARTHUR J ETAL U U s po U 1192966 COSGROVE MATHEW T THE RESERVE AT SCHERTZ II U3 619230 MUZNY ALAN G & BARBARA K <all other values> 60' Expansion 86' Expansion 120' Expansion Abandon 1" 6" 18" Schertz Gravity Neighboring Gravity U Hydrant Highways 60' Proposed 86' Proposed 120' Proposed Other Cities 2" 8" 20" Schertz Pressure Private Pressure ! P Manholes Major Roads 60' Extension 86' Extension 120' Extension Future TXDOT 3" 10" 24" Highway 4" 12" 30" 16" 36" Minor Roads KE L IVY AN U 619017 BOECK FARM CO LTD 4 JE IN TA r) o t c ne N OU R IV Y M ED U U Y IV LAK U U E ( ed U U JAD RD t as st e &W U 119 386 2 61 38 9 11 51 U 38 9 11 OR AN M Y IV n Co AF N OW 1193850 RESERVE AT SCHERTZ HOA INC 619214 TUDYK CHARLES & VIRGINIA LE CT T AY GR 2 85 93 1 1 119 386 6 IVY EN N 1193853 619201 LEANIN DIPPER INVESTMENTS LTD ETAL U 119 386 3 119 385 5 U 119 386 7 119 386 4 119 385 6 U U 119 386 5 119 385 7 119 385 4 119 386 8 IVY L JA 119 385 8 U U U IVY MISTY JE IVY 119 384 8 LA U IV Y EL L 119 384 7 ON N IVY U VE DO GA GE C ) ON AY W 119 384 6 FF LU B A URU IVY ad Ro 619193 TRIPLE H DEVELOPMENT LLC 119 384 5 E DR NI G BO E wn yto ra (G CT U r) n 44 11938 io ns EK U cto pa DE R U NIC SM U FIE LD 6 ES D 69192 AVID & EV ELY TOR R U YT PA SC E U HA e nn Ex 619030 VELMA DEVELOPMENT LLC U AN Y U WA Co STOB 669191 BS E & HE DWARD H ATHE RC U ' 86 CARD 6 INAL 69190 LAW REN & RO SE-LI CE DAVI LIIAN D 669 MAR 189 ICRU Z&A LFAR O M & KA REN K BERN AL 619198 BARNETT GLENN H & JANET K uth So 6 N ED 69188 WAR DN U 12 HE 0285 NR YE 2 &M ELV A & rth No U STU LTZ U d( ADDI SO U e os ON MO IVY op VD BL LENE S HT Y D JO U Pr N GARC 6 IA JO 69187 SE E III & AR U IW AY ND IE LA U PENNY PKWY EL LP ON D E AV 619195 STULTZ HENRY E & MELVA S HT Y PO W LIA PK M JA A OZ G R R E OW L F IVYU IE LL HA R ZA LA 619193 TRIPLE H DEVELOPMENT LLC E SH 619038 VELMA DEVELOPMENT LLC H LIE 1 Inch = 300 Feet 200' Buffer 0 150 300 600 900 1,200 Feet