IFX-Mx-03
Transcription
IFX-Mx-03
THE ULTRASONIC FLOW SOLUTION - HEAT METER IFX-Mx-03 Ultrasonic Residential Heat Meter for heating & cooling from DN15 to DN50 MID Approved (MI004) Warranty conditions are available on this website: www.isoil.com only in English version IFX-Mx-03 INDEX TECHNICAL DAT .......................................................................................................................................................... 3 TABLE OF HEAT METER4…………..……………………………………………………………………………….4 INSTALLATION............................................................................................................................................................. 5 MOUNTING AND CONNECTIONS……………………………………………………………………………………………………… .7 DIMENSIONS ................................................................................................................................................................. 8 SEALING.……………………………………………………………………………………………………………..10 OPERATIONS……………………………………………………………………………………………………… .12 ERROR CODES……………………………………………………………………………………………………….20 HOW TO ORDER…………………………………………………………………………………………………...…21 CERTIFICATION…………………………………………………………………………………………………...…22 The manufacturer guarantees only English text available on our web site: www.isoil.com Page 2 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 TECHNICAL DATA STANDARD FEATURES Application Commercial (local or district heating systems) Heating and cooling Range DN15 to DN50 -MI004 Version Compact Separate (meters of cable to be ordered until 5 meters) Internal Lithium Battery 3,6 V - LiSOCl2 (11 years lifetime) 86 to 106,7 KPa ( Atmospheric); <1,6 MPa (Fluid-PN16) Ambient: 5… +55°C (Calculator); -30… +55°C (Flow sensor) Fluid 5…+130°C <=2,5m3/h; 10…+130°C >= 3,5 m3/h PT100 (PT1000 option) Platinum reistance – 2 wires Matched pairs (supplied in couple) 0…180°C (3…150K or 2…150K on request) EN60751 / EN1434-2 < 93% (IP65) 0÷100% (IP 67 on request) Power supply Pressure Temperature Temperature Probes Humidity Range Accuracy Class 2 to EN1434; (typically 1%) Energy Units kWh, MWh, GJ, Gcal (Max thermal power value 2,63 MW) Additional Inputs 2 programmable inputs, typically for external water meters Display 8 digits-LCD Data Logger Hour, day, month. Reading by remote tool or monthly by display Capacity: 960h; 1116d; 36 last m; The manufacturer guarantees only English text available on our web site: www.isoil.com Page 3 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 OTHERS FEATURES Housing materials Brass body Protection Rate IP65 (IP 67 on request) Transmitter DN50 ceramic plate Remote Cable length Until 5 meters Status By 2xLED inside electronic box pushing test button Output 2x Pulses and/or Mbus; RF 868Hz module Connections Thread until 2”; DN50 flanged Warranty 12 months Technology Time-on flight measurement method WEEE Marking 2002/96/EC Conformity 2004/108/EC as EMC; 2006/95/EC as Low Voltage directives MID Certification Yes – MI004-EN1434 part 1-6, Environment Class C; Electromagnetic E2 2004/22/EC Annex 1 CE Certification Yes TABLE OF HEAT METER flow rates, lengths, connection thread (flanges) and the pressure losses P, at q =qp: Limits of flow rate, m3/h Permanent Upper Lower flow rate flow rate flow rate qp qs, qi 0,6 1,2 0,006 1,0 2,0 0,01 1,5 3,0 0,015 1,5 3,0 0,006 2,5 5,0 0,025 2,5 5,0 0,01 3,5 7,0 0,035 6,0 12,0 0,06 6,0 12,0 0,024 10,0 20,0 0,04 10,0 20,0 0,100 15,0 30,0 0,150 15,0 30,0 0,06 Threshold value of flow rate, m3/h 0,003 0,005 0,003 0,003 0,005 0,005 0,017 0,012 0,012 0,02 0,02 0,03 0,03 Overall length L, mm Pressure losses at 110 110 110 110 130 130 260 260 260 300 300 300 300 23 11,3 17,1 17,1 19,8 19,8 4 10 10 18 18 12 12 Joining to the pipeline (Thread – G, flange–DN) G3/4“ G3/4“ G3/4“ G3/4“ G1“ G1“ G1 1/4“ G1 1/4“ G1 1/4“ G2“or DN40 G2“or DN40 DN50 DN50 qp, kPa (Price list includes only standard version) The manufacturer guarantees only English text available on our web site: www.isoil.com Page 4 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 INSTALLATION It is forbidden to wire signal cables nearby (less than 5 cm) with power cables or cables of other devices. It is forbidden to change length of a cable about temperature probes Factory-installed temperature sensors do not split, shorten or extend the cables. Calculator can be mounted in several different ways: - Wall mounting, without possibility sealing of mounting - Wall mounting, with possibility sealing of mounting - Mounting on standard DIN-rail - Panel mounting - Direct mounting on ultrasonic flow sensor housing, turning every 90o (only when the temperature of the flow does not exceed 90 ° C): On the flow sensor with a thread connection On the flow sensor with flange connection The manufacturer guarantees only English text available on our web site: www.isoil.com Page 5 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 On the wall Panel mounting on standard DIN-rail Adapter plate according to EN1434-2:2007 for wall mounting of calculator (if the aperture in the wall is too large for the calculator) The manufacturer guarantees only English text available on our web site: www.isoil.com Page 6 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 MOUNTING OF FLOW SENSORS - For flow sensors DN15…DN32: no requirements for straight pipeline length in upstream and downstream directions. - For flow sensors DN40…DN50: upstream straight pipeline length must be not less 5DN and downstream straight pipeline length must be not less 3DN Avoid the flow sensor installation near after the pumps which can cause cavitations. Flow sensor can be mounted both vertically and horizontally in pipelines. Vertically mounting of the flowmeter is allowed only if flow direction in the pipeline is from down to up. The direction of the sensor installation (is indicated with the arrow on the label of flow sensor) must match with the flow direction in pipeline. MOUNTING OF TEMPERATURE SENSORS Temperature sensors are mounted by head upwards, is perpendicular to the pipe axis or inclined by 45 ° angle on fluid flow direction so that the sensing element has been inserted in medium at least up to the pipe axis or beyond (as shown in Annex C). For meters with flow sensor joining G3 / 4 ', G1, and G1 ¼' – one temperature sensor is mounted in the flow sensor housing. The manufacturer guarantees only English text available on our web site: www.isoil.com Page 7 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 DIMENSIONS Mechanical dimensions of calculator of heat meter IFX-03 Threaded connections G3/4“ lenght L=110 mm The manufacturer guarantees only English text available on our web site: www.isoil.com Page 8 of 22 Threaded connections G1“ lenght L=130 mm Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 Threaded connections G1 1/4“, lenght L=260 mm Threaded connections G2“ , lenght L=300 mm Flanged connection DN40, mounting lenght L =300 mm The manufacturer guarantees only English text available on our web site: www.isoil.com Page 9 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 Flanged connection DN50 , lenght L= 270 mm SEALING Calculator general view: the cover is closed, and the cover is opened (1-verification seal, 2-manufacturer security seal , 3 –mounting seal) The manufacturer guarantees only English text available on our web site: www.isoil.com Page 10 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 angled 45o perpendicular Mounting for meters with threaded Direct probes connection G3/4, G1 or G1 ¼ in accordance with EN1434-2 (standard 1,5 meter cable lenght) Mounting for other types with longer probes from connection G2“ in accordance with EN1434-2 (standard 2,5 meter cable lenght) The manufacturer guarantees only English text available on our web site: www.isoil.com Page 11 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 OPERATIONS The information can be displayed using control button which are on the top Integral parameters values (1.2) or– if at least one error has been detected – error code (1.1) are displayed if the button has not been presed for more than 60 seconds. (INT - integral parameters, BIL – statistical data, INF- informative parameters - long press ( 3 s) - shift to the right - short press( 3 s) – shift down) The manufacturer guarantees only English text available on our web site: www.isoil.com Page 12 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 ID 1.1 Parameter Error code with data stamp of starting oferror Value Description All three displays, will be displayed in turns in one second interval INT BIL INF INT BIL INF INT BIL INF Calculator errors Temperature 2 errors Temperature 1 errors Flow errors Are shown only at an error in meter work INT BIL INF Description of Error codes is presented in p. 6.3.3 1.2 Energy for heating 1.3 Energy for cooling Are shows only in the heating and cooling energy meters 1.4 Integrated energy of tariff 1 "Snowflake" indicates that the tariff is linked to the meter of cooling energy INT 1.5 Integrated quantity of heat-conveying liquid 1.7 Integrated reading of pulse input 1 "Snowflake" indicates that the tariff is linked to the meter of cooling energy INT BIL INF INT BIL INF The additional flow sensor can be connected to a pulse input 1 INT 1.10 1.11 1.12 BIL INF Integrated reading of pulse input 2 The additional flow sensor can be connected to a pulse input 1 INT 1.9 INF Integrated energy of tariff 2 1.6 1.8 BIL BIL INF Segment test changes each 1 second INT BIL INF INT BIL INF INT BIL INF Working hours without a energy calculation error Customer number Corresponds to a wire transmission via MBus protocol INT BIL INF INT BIL INF Control number The manufacturer guarantees only English text available on our web site: www.isoil.com Page 13 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 Quantity of thermal energy on set day with date stamp Quantity of thermal energy for cooling on set day with date stamp Changing with date stamp every 1 second INT BIL INF INT BIL INF INT BIL INF INT BIL INF Tariff register 1 on set day with date stamp Changing with date stamp every 1 second INT BIL INF INT BIL INF Tariff register 2 on set day with date stamp Changing with date stamp every 1 second INT BIL INF INT BIL INF Volume of liquid on set day with date stamp Changing with date stamp every 1 second INT BIL INF INT BIL INF st 1 pulse input pulse value on set day with date stamp Changing with date stamp every 1 second INT BIL INF INT BIL INF nd 2 pulse input pulse value on set day with date stamp Quantity of thermal energy on set day of previous month with date stamp The manufacturer guarantees only English text available on our web site: www.isoil.com When meter is intended for heating and cooling, the two separate displays are shown. Changing with date stamp every 1 second Changing with date stamp every 1 second INT BIL INF INT BIL INF INT BIL INF INT BIL INF Page 14 of 22 The user chooses set day in the month according to needs. (If it is set up 31, the data will be recorded in the last day of the month) Registration Time: 23:59:59 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 2.9 2.10 2.11 2.12 2.13 2.14 2.15 Quantity of thermal energy for cooling on set day of previous month with date stamp Tariff register 1 on set day of previous month with date stamp Tariff register 2 on set day of previous month with date stamp Volume of liquid on set day of previous month with date stamp Changing with date stamp every 1 second INT BIL INF INT BIL INF Changing with date stamp every 1 second INT BIL INF INT BIL INF Changing with date stamp every 1 second INT BIL INF INT BIL INF Changing with date stamp every 1 second INT BIL INF INT BIL INF st 1 pulse input pulse value on set day of previous month with date stamp 2 Changing with date stamp every 1 second INT BIL INF INT BIL INF nd pulse input pulse value on set day of previous month with date stamp Changing with date stamp every 1 second INT BIL INF INT BIL INF Maximum Power of previous month with date stamp Changing with date stamp every 1 second INT 2.16 BIL INF Minimum Power (or maximum Power for cooling) of previous month with date stamp Changing with date stamp every 1 second INT The manufacturer guarantees only English text available on our web site: www.isoil.com BIL INF Page 15 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 2.17 Maximum flow rate of previous month with date stamp Changing with date stamp every 1 second INT 2.18 2.19 2.20 2.21 2.22 2.23 Maximum temperature in flow pipe of previous month with date stamp Maximum temperature in return pipe of previous month with date stamp Maximum temperature difference of previous month with date stamp Minimum temperature in flow pipe of previous month with date stamp Minimum temperature in return pipe of previous month with date stamp Minimum temperature difference of previous month with date stamp 3.1 Thermal power 3.2 Flow rate The manufacturer guarantees only English text available on our web site: www.isoil.com BIL INF Changing with date stamp every 1 second INT BIL INF INT BIL INF Changing with date stamp every 1 second INT BIL INF INT BIL INF Changing with date stamp every 1 second INT BIL INF INT BIL INF Changing with date stamp every 1 second INT BIL INF INT BIL INF Changing with date stamp every 1 second INT BIL INF INT BIL INF Changing with date stamp every 1 second INT BIL INF INT BIL INF Page 16 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 3.3 3.4 3.5 3.6* Temperature in flow pipe INT BIL INF INT BIL INF INT BIL INF INT BIL INF INT BIL INF INT BIL INF INT BIL INF Next replacement date of the battery 3.8* Real time clock 3.11* INF Temperatute difference Real time calendar 3.10* BIL Temperature in return pipe 3.7* 3.9* INT Yearly set day Monthly set day Tariff 1 Tariff 1, when T1-T2 < 10.0 oC INT BIL INF It is possible to choose: One of the measured parameters, 1st or 2nd pulse input (if it is configured as an input), one of the temperature or the temperature difference. Or >10.0 oC INT BIL INF Or in interval from 10.0 to 40.0oC (changes each 1 s.) INT BIL INF INT BIL INF Or there is the time interval in hours (0024h.) INT BIL INF Or tariff is activated The manufacturer guarantees only English text available on our web site: www.isoil.com Page 17 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 directly by pulse input: INT 3.12* Tariff 2 3.13* 1st pulse input/output configuration BIL INF Similarly ID 3.11, only „L1“,changes in the „L2“ Input: INT BIL INF Input (tariff activation): INT BIL See 3.11 Inputs: Can be configured only for a quantity of water. Maximum pulse resolution is displayed 0.00001 m3. Outputs: Can be configured for a quantity of water (m3), for heating (In a shown case) / cooling(additional snowflake is displayed) energy or to one of tariffs. INF Outputs: energy, quantity of liquid INT BIL INF Tariff INT BIL INF INT BIL INF Tariff condition: INT nd BIL INF 3.14* 2 pulse input/output configuration Similarly ID 3.13, only „1“,changes in the „2“ 3.15 Type of heat-conveying liquid 3.16 Pressure value for energy calculations "160E4"-corresponds to the pressure 1.6 MPa 3.17* Customer number Are transferred on telegram Mbus Type of heat-conveying liquid: “---“ (crosses) - water INT 3.18 See 3.13 BIL INF Softvare version number The manufacturer guarantees only English text available on our web site: www.isoil.com Page 18 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 3.19 3.20* 3.21 3.22* Serial number INT BIL INF INT BIL INF INT BIL INF INT BIL INF MBus adress Working hours without a power calculation error Battery operation time Remark: Values of the parameters marked with "*" and energy measurement units (MWh, Gcal or GJ) can be modified by installing a meter. Replacement is possible via optical interface and in conjunction with the special configuration programme in a test mode, when jumper is set In the same way it is possible to switch off indication of irrelevant parameters. The manufacturer guarantees only English text available on our web site: www.isoil.com Page 19 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 ERROR CODES Calculator errors Temperature 2 errors Temperature 1 errors Flow errors INT BIL INF Error code may consist from up to 4 symbols. Each symbol may have values 0…8 Code Status of calculator Status of temperature sensor 2 (return pipe) Status of temperature sensor 1 (flow pipe) Description 0 - no error, normal operation 1 - warning – ending battery life 2- temperature difference is greater than the permitted limits 4- temperature difference is less than the permitted limits 8- electronics failure 0- no error, normal operation 4- short circuit 8- sensor failure (oper circuit or short circuit) 0- no error, normal operation 4- short circuit 8- sensor failure (oper circuit or short circuit) Status of flow sensor 0- no error, normal operation 1- no signal, flow sensor is empty 2- flow flows in an reverse direction 4- flow rate greater than 1.2∙qs (are displayed q=1,2qs) 8- electronics failure Active error codes are added and simultaneously displayed, if it is detected more than one error 3 - corresponds errors 2 + 1 5 - corresponds errors 4 + 1 7 - corresponds errors 4 + 2 + 1 9 - corresponds errors 8 + 1 A - corresponds errors 8 + 2 B - corresponds errors 8 + 2 + 1 D - corresponds errors 8 + 4 + 1 E - corresponds errors 8 + 4 + 2 F - corresponds errors 8 + 4 + 2 +1 When value of one digit of error code is ≥ 8, at least – calculation of thermal energy and total of volume of water and operation time without errors are stopping In case of the flow sensor error "4" - duration of time, "when the flow rate q> 1.2 ∙ qs" is registered in addition. The manufacturer guarantees only English text available on our web site: www.isoil.com Page 20 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 HOW TO ORDER (see price list for others options) The manufacturer guarantees only English text available on our web site: www.isoil.com Page 21 of 22 Isoflux IFX_Mx_03 data Sheet_v1302 IFX-Mx-03 CERTIFICATION