arium® Water Purification Systems
Transcription
arium® Water Purification Systems
arium® Water Purification Systems A Profile of Sartorius Stedim Biotech Sartorius Stedim Biotech is a leading provider of cutting edge equipment and services for the development, quality assurance and production processes of the biopharmaceutical industry. Its integrated solutions covering fermentation, filtration, purification, fluid management and lab technologies support the biopharmaceutical industry around the world to develop and produce drugs safely, timely and economically. Sartorius Stedim Biotech focuses on single-use technologies and value added services to meet the rapidly changing technology requirements of the industry it serves. Strongly rooted in the scientific community and closely allied with customers and technology partners, the company is dedicated to its philosophy of turning science into solutions. Headquartered in Aubagne, France, Sartorius Stedim Biotech is listed on the Eurolist of Euronext Paris. With its own manufacturing and R&D sites in Europe, North America and Asia and a global network of sales companies, Sartorius Stedim Biotech enjoys a worldwide presence. Its key manufacturing and R&D site is in Germany. 2 Contents The Benefits of the arium® Family at a Glance arium® basic – A Cost Effective Alternative arium® 61316 Reverse Osmosis System Page 5 Page 16 Page 26 Environmentally Friendly Use and Quality Assurance Page 38 Solutions for Any Application – Overview of the Systems Page 6 arium® pro and basic – Equipment and Specifications The arium 61316 Reverse Osmosis System Step by Step Technical Service and Support Page 18 Page 28 Page 39 arium® pro Ultrapure Water Systems for Critical Applications arium® EDI 61215 – ASTM Type 2 Pure Water System Page 8 Page 20 Optimal Purification with the arium® pro Family arium® 61215 EDI System Design Page 10 Reliable Water Quality Page 12 Work without Compromise with the arium® pro Family Page 14 ® arium® 61316 – Specifications Page 30 Ordering Information Page 40 arium® 613L Reverse Osmosis System Application | System Overview Page 22 Page 32 Page 48 Functionality of EDI Technology arium® 613L Reverse Osmosis System Specifications Page 24 arium® 61215 EDI – Specifications Page 25 Page 34 Intelligent Design: Flexibility in the Laboratory Page 36 3 In the biopharmaceutical industry, universities, and clinical institutes, it is increasingly important for our customers to use laboratory grade water for the various applications. More demanding requirements and increasingly sensitive analysis equipment set a benchmark to reach the required standard of high quality water. However, with the range of purification technology available, it can often be difficult to select the right equipment to achieve the necessary water quality for your application. The feed water is also an important consideration. 4 The product overview on the rotary disk should help you find the right device for your applications. It also indicates recommended pre-treatment depending on the feed water. The disk provides a general first impression of the arium® family and how it can meet all of your scientific laboratory requirements, taking you from feed water through to ultrapure water. Of course, our specialists are also on hand for individual consultation. ASTM type 1, type 2 or type 3 – Sartorius Stedim Biotech has the right device depending on the application and required water quality. This brochure gives an overview of all water systems with a focus on the new, upgraded versions of our ultrapure water systems: the arium® pro product line offerings. The Benefits of the arium® Family at a Glance All arium® systems are developed by experts, combining know-how with the highest quality standards. The arium® family has standardized features that make working with the devices as simple and efficient as possible. A Higher Standard of Quality The efficient removal of all possible contamination guarantees consistent water quality for optimal and reliable results in any application. Cost Effective and Environmentally Friendly Components and materials in the cartridges have been designed to complement each other resulting in a long service life and optimal purification making these units highly cost effective. Easy to Use All necessary information can be accessed instantly and easily on the practical touch display. Maximum Flexibility The diverse options for configuring the arium® systems in your laboratory based on your individual requirements means optimal flexibility during work and when dispensing water. 5 Solutions for Any Application – Overview of the Systems Sartorius Stedim Biotech offers the right solution for every application and its required water quality, from the pretreatment of feed water in order to allow for efficient use of downstream cleaning steps, to the required polished product water. Type 1 Water Quality The newly developed arium® pro range produces ultrapure water for critical applications. There are four different systems to choose from depending upon your individual requirements. The systems are available both with and without an integrated TOC monitor. In addition, there is also the arium® basic model, a streamlined, cost effective alternative to the arium® pro DI with the most important product features. arium® pro DI arium® pro UV arium® pro UF arium® pro VF arium® basic Type 2 Water Quality For the production of ASTM type 2* water quality, Sartorius Stedim Biotech offers the arium® 61215 EDI system for general applications. An alternative to this system is the arium® 615DI cartridges, which produce type 2* water when used for the secondary treatment of reverse osmosis water. arium® 61215 EDI arium® 615DI * depending on feed water 6 Water Softening for Pretreating Water for arium® RO and EDI Systems For particularly hard water, we recommend the arium® 615S water softener, used to pretreat the water in order to protect the device cartridges. arium® 615S** Complete Deionization Cartridges for Pretreating Water for arium® pro Systems For saline water, we recommend the arium® 615DI deionization cartridges, used to produce completely deionized water as pretreatment for arium® pro ultrapure water systems. arium® 615DI** ** For further information, request the data sheets for these products. Type 3 Water Quality The arium® reverse osmosis systems produces ASTM type 3* water quality. These systems are designed to meet water requirements for general laboratory applications, such as cleaning and rinsing laboratory equipment, as well as for water supplied to an entire building. arium® 61316 – produces up to 16 l/hr arium® 613L – produces up to 50–300 l/hr * depending on feed water 7 arium® pro Ultrapure Water Systems for Critical Applications The new Sartorius Stedim Biotech arium® pro ultrapure water systems reliably produces ASTM type 1 water (18.2 MΩ) and fulfill all requirements for reagent grade water for critical and routine applications. 1 Cartridge Sets For Producing Ultrapure Water In ultrapure water systems, cartridge sets comprising a pretreatment and secondary treatment cartridge. The cartridges are designed for optimal crossflow of resins. The flow of water moves from the top to the bottom of the cartridges to achieve optimal cleaning motion and to prevent the medium inside the cartridges from mixing. – contain granulated, catalytically-active, activated carbon of the highest quality – contain high efficient mixed-bed ion exchange resins – have the highest ion exchange capacity available in the industry and reduce operating costs 2 Dual Wavelenght UV Lamp (185 | 254 nm) For Removing Organic Substances The UV lamp reliably removes organic substances (TOC or total organic carbon), effectively preventing bacterial growth. TOC content can also be monitored with an optional integrated TOC monitor in the arium® pro. 8 3 Ultrafilter For Removing Macromolecules The ultrafilter separates bacterial endotoxins, pyrogens, DNA and RNA. The single-use, hollow-fiber ultrafilter achieves high flow rates and has a low adhesion to leachable substances. 2 3 4 Sterile Final Filter Sartopore® 2 150 Membrane Filter Capsules The Sartopore® 2 150 membrane filter provides additional protection from particles and bacteria and impresses with its constant flow rate. The 0.45 + 0.2 μm polyether sulfone double membrane guarantees microbiological retention in compliance with HIMA and ASTM guidelines for sterile filters and is therefore particularly suited for critical applications. 8 7 6 5 4 5 Display For Complete Control The newly developed display with glass interface and touch screen function is simple to use with the integrated text support. All necessary information can be accessed instantly. A range of basic settings can be restricted to authorized users only by entering a PIN code. Colored warning and system messages provide modern convenience in day-to-day handling of the device. 1 6 Water Dispensing Manual, Volume, and Time Control The slider on the display enables continuous manual water dispensing, during which the flow rate can be freely regulated between 0.5 and 2 l/min. The volume and time controlled dispensing facilitates precise proportioning and avoids waiting for water to be dispensed. 7 Conductivity Measurement In Feed Water and Product Water Measurement of both conductance values help prevents rapid wear of cartridge sets, where applicable. 8 Electronic Connections For Data Storage The newly developed arium® pro features various electronic connections and particularly stands out with its modern data storage option via SD card. It also has the option of transferring data to a printer or via a PC using an RS-232 serial interface. 9 Optimal Purification with the arium® pro Family The new arium® pro range comprises of four different models that can be specially customized to our customers' requirements. It provides optimal water quality for reliable analyses. arium® pro DI This standard system of the arium® pro range contains a cartridge set and sterile filter. The cartridge set is selected individually based on the feed water quality and intended application and comprises a pretreatment cartridge followed by a secondary treatment cartridge. All cartridges use patented Sartorius technology for the creation of ultrapure water that exceeds ASTM criteria for type 1* reagent grade water. Applications: – buffer and media production – reagent manufacture – rinsing of glass containers – inorganic analytical methods: IC, AAS, ICP, ICP-M arium® pro UV (with Optional TOC Monitor) Besides the purification cartridges, the arium® UV device also has a 185 | 254 nm dual wavelenght UV lamp to reliably remove organic substances (TOC). At the same time, the UV radiation inactivates microbial cells via the adsorption of the UV light. This facilitates a sterilized production of ultrapure water. Applications: – chromatography – standard HPLC – analysis of trace elements 10 – photometric methods – reagent manufacture – mass spectrometry * depending on feed water arium® pro UF The arium® UF contains an ultrafilter for removing endotoxins, pyrogens, DNA, and RNA. A 5,000 MWCO (5 kDa) microporous membrane removes macromolecules from the water so that an endotoxin level of < 0.001 EU/ml is achieved. Applications: – cell cultivation – DNA sequence analysis – IVF (in vitro fertilization) – general biochemical applications arium® pro VF (with Optional TOC Monitor) The arium® VF model combines the UV lamp and the ultrafilter in one device to produce water for particularly critical standards, cell cultivation, and chromatography applications. Applications: – chromatography – electrophoresis – HPLC – IVF – molecular biology – cell cultivation – RNA|DNA purification – reagent manufacture – PCR 11 Reliable Water Quality The arium® pro range produces laboratory grade water that meets the ASTM type 1* standard. With 18.2 MΩ + cm as well as the lowest TOC and endotoxin levels, optimal reliability in applications is guaranteed. Product Water Quality pro DI pro UV pro UF pro VF Specific resistance (MO + cm) 18.2 18.2 18.2 18.2 TOC content (ppb)1 @ 25 °C <5 <2 <5 <2 Endotoxins (EU/ml) N/A N/A < 0.001 < 0.001 Particles (at 0.2 μm) < 1/ml < 1/ml < 1/ml < 1/ml Bacteria (CFU/1000 ml) <1 <1 <1 <1 up to 2 up to 2 up to 1.7 up to 1.7 2 Flow rate (l/min) N/A = not applicable 1 Values may vary depending on the quality of the feed water and the content of impurities in the feed water, as well as the type of cartridge used. 2 At a pressure of 2 bar, without final filter Ultrapure Water for Critical Applications The arium® pro VF model produces RNase free and DNase free water with a TOC content of 1–2 and an endotoxin value of < 0.001 EU/ml. 12 arium® pro VF* Laboratory Grade Ultrapure Water The diagram illustrates how water quality fluctuates in freshly prepared ultrapure water. Only ultrapure water without peaks, like that produced with the arium® pro VF, guarantees the highest grade water for stringent requirements. Competitor A* * HPLC application (reverse-phase chromatography) elution with acetonitrile and water 13 Work without Compromise with the arium® pro Family The arium® pro family has been developed to tailor to the requirements of the user. The simple and intuitive glass interface enables each user to operate the system securely as well as having fast access to all relevant data. Thanks to the different options for water dispensing, working with the ultrapure water system is even more convenient. 15:32 23.06.09 0.055 µS/cm c 1.0 ppb TOC Care menu Display The new display with innovative glass interface features impressive operations. The intuitive menu navigation makes working with the system simple while the integrated output function can be directly controlled. Features include: – setting limit values for conductivity of feed water and product water – PIN-protected for basic settings (e.g., setting limit values) – colored warning and alarm messages that indicate a required cartridge change, for example, and which are also emphasized by flashing graphic symbols – constant control of the water and all important parameters visible via the display (e.g., display of system status, countdown for next cartridge or filter change) – direct and continuous output of details, such as feed water and product water conductivity via a printer or PC, as well as data storage on an SD card All illustrations refer to arium® pro systems with integrated TOC monitor. 14 Dispenser Unit The new arium® pro allows users for manual, volume or time controlled water dispensing options via the display. Manual Output (Slider) – continuous transition from 0.5 to 2 l/min – graphic support 15:09 01.02.10 15:09 01.02.10 0.055 µS/cm c 0.055 µS/cm c 1.0 ppb TOC 1.0 ppb TOC 1.2 l Stop Volume Controlled Output – 0.1 – 60 l – 0.1 – 2 l (in 100 ml increments) – 2 – 5 l (in 500 ml increments) – 5 – 60 l (in 1000 ml increments) – display of remaining dispensing volume – volume save function Housing and System Setup The compact design of the device enables you to save space when positioning the system. Its flat surface can accommodate containers or even a second device. The high quality and robust housing guarantees high practicality in your laboratory environment. The design of the units has: – easy-to-open door provides faster access to consumables (time-saving cartridge changes) – separation of customer and service areas in the system (no contact with electronics) 4.0 min Stop Time Controlled Output – output from 30 sec to 59 min – display of remaining time – time save function 15 The arium® basic – A Cost Effective Alternative The arium® basic standard system fulfills the fundamental requirements of an ultrapure water system. It produces ASTM type 1* water which can be used for both critical and routine applications. The arium® basic is a cost effective alternative. Only the most vital functions are included for meeting the requirements of ultrapure water production – streamlined without compromising quality. * depending on feed water 16 Common Applications: – atomic absorption (AA) – ion chromatography – inductively coupled plasma mass spectrometry (ICP-MS) – rinsing of glass containers – preparation of buffers and media – reagent manufacture Pump Design and Features of the arium® basic System: – innovative glass interface with touch screen function – time controlled dispensing – manual, freely adjustable flow rates up to 2 l/min – conductivity measurement for product water – simple menu navigation with integrated text support – data storage via Ethernet or printer – PIN-protected access to basic settings and service – service and alarm functions supported by graphic displays – intelligent alarm system Pre-treatment cartridge Inlet Pre-treatment cartridge Display Outlet Uniform Technology The arium® basic system comes with all of the important features for the production of ultrapure water, including the same high quality cartridge sets as with the arium® pro devices, and achieves the same superior water quality as the arium® pro DI. 17 arium® pro and basic – Equipment and Specifications Function | Equipment Manual dispensing (adjustable via slider) Volume controlled dispensing Time controlled dispensing Monitoring of inlet conductivity Dispensed water display Temperature monitoring Ethernet (not yet available) Data backup via (optional) printer Data backup on SD card Connection for remote dispenser Sanitization port Drainport UV lamp Ultrafilter Options TOC Foot switch Level sensors (2 pcs.) Remote dispenser Versions Benchtop system Wall-mounted system Below-bench unit 18 basic pro DI pro UV pro UF pro VF Product Water Quality basic pro DI pro UV pro UF pro VF Specific resistance (MO + cm): 18.2 18.2 18.2 18.2 18.2 Conductivity (μS/cm): 0.055 0.055 0.055 0.055 0.055 TOC content (ppb) @ 25 °C: <5 <5 <2 <5 <2 Endotoxin content (EU/ml): N/A N/A N/A < 0.001 < 0.001 Particles (at 0.2 μm): < 1/ml < 1/ml < 1/ml < 1/ml < 1/ml Bacteria (CFU/1000 ml): <1 <1 <1 <1 <1 Flow rate (l/min) : up to 2 up to 2 up to 2 up to 1.7 up to 1.7 Empty weight: 17 kg 17 kg 18 kg 18 kg 18 kg Operating weight: 27 kg 27 kg 28 kg 28 kg 28 kg Operating weight with integrated TOC monitor: N/A N/A 29 kg N/A 29 kg 1 2 Feed Water Requirements for arium® pro and basic Specifications Dimensions (W + H + D): Interfaces: Power supply: 35 + 49.2 + 45.1 cm ® SD card (for arium pro devices only) RS-232 100–240 V AC (± 10%) 50–60 Hz, 80 W (max.) 130 VA (max.) Minimum inlet pressure: Maximum inlet pressure: depressurized 6.9 bar Specific conductance RO water: Distilled water: Deionized water: 100 μS/cm 4 μS/cm 20 μS/cm TOC: Turbidity: Silica: < 50 ppb < 1 NTU < 1000 ppm Values may vary depending on the quality of the feed water and the content of impurities in the feed water, as well as the type of cartridge used. 2 At a pressure of 2 bar, without final filter 1 19 arium® EDI 61215 – ASTM Type 2* Pure Water System The Sartorius Stedim Biotech arium® EDI 61215 pure water system fulfills all requirements for modern water purification systems. The arium® EDI 61215 consistently and reliably produces ASTM type 2* water in accordance with the specific standards – for successful work in the laboratory. * depending on feed water 20 Quick and Simple at a Glance The display provides all information necessary for a pure water system. Simple and clear menu navigation makes it easy to work with the system. If the limit values entered are exceeded, the service and alarm functions signal the breach. All important parameters can be accessed quickly and easily at the push of a button. – display of conductance for feed water and product water – rejection rate – tank level – temperature Pure Water Quality for General Laboratory Applications The arium® 61215 EDI system guarantees the removal of all contamination in tap water. As well as pretreatment and purification via the reverse osmosis module, the device also performs softening and electronic | chemical deionization. This procedure guarantees high water quality. Common Areas of Application: – preparation of microbiological media and buffers – reagent manufacture – pharmaceutical applications – electrophoresis – general biotechnological applications – feed water for ultrapure water systems – feed water for laboratory devices, such as autoclaves and purification machines 21 arium® 61215 EDI System Design Pretreatment Cartridge For Protection of the Reverse Osmosis Module In the first stage, coarse contamination is removed from the water to protect the reverse osmosis membrane. Conductivity| Retention rate analysis Solenoid Pressure valve regulator Inlet Conductivity cell – activated carbon filter for the removal of chlorine and organic substances – 5 μm particle filter to prevent blockage of the module and to extend service life Pump Solenoid valve Reverse Osmosis Module For Effective Removal of Contamination Reverse osmosis removes all contaminates to a certain degree. The reverse osmosis module filters out 98–99% of charged ions and 99% of all dissolved substances as well as particles and microorganisms. The constant flow rate also guarantees consistent crossflow of the membrane, ensuring optimal water purification. 22 Pretreatment cartridge RO module #1 RO module #2 Softener Reduces Calcium Carbonate The softener cartridge removes remaining calcium residues from the water, ensuring optimal water quality for further processing via electronic | chemical deionization. – effective removal of calcium residues – increases service life of the EDI module Display RO permeate Concentration chamber Conductivity cell Conductivity cell Concentration chamber Concentration chamber Cathode Wastewater Softener EDI Module Ion Removal via Ionpure® EDI Technology Electronic | chemical deionization removes remaining ions from the water in the third purification stage. Anode – Continuous regeneration of the ion exchange resins ensures constant quality and long service life Product water EDI stack RO pressure tank Pressure Tank (30 l, 50 l, 70 l, and 100 l) Secure Storage of Water The completely sealed pressure tanks consist of an FDA-approved, double-butyl membrane capable of storing up to 100 l of pure water. Filling the tank creates an internal pressure of up to 2.5 bar. This removes the necessity for an additional pump for distributing the product water to the point of use. Drain – reduction of contamination through microbes and gases – space-saving setup in desired locations – transfer of product water with up to 2.5 bar to the point of use 23 Functionality of EDI Technology The core of the arium® 61215 EDI system is an EDI module with Ionpure® technology. RO water is fed through the module at right angles to an applied voltage and, thus water gets deionized. The EDI technology is based upon the principle that ions move towards the electrodes in an electrical field. The ions are only allowed to pass through in one direction. The negatively charged anions move towards the anode and the positively charged cations towards the cathode. On their way, the ions pass through ion-selective membranes, the anions through an anion-selective membrane and the cations through a cation-selective membrane. This creates areas with increased ion concentration, known as concentration chambers, and areas with reduced ion concentration, or cleaning chambers. So that this process can proceed without turbulence and back-mixing, the areas are filled with ion exchange resin. The ions are bound to the ion exchange resin and move on its surface to the concentrate areas. Through the dissociation of the water into OH- and H+ ions, this resin continues to regenerate and is capable of further ion exchange. No chemicals are required for regeneration. The concentrate areas are sprayed with a low volume flow to transport the ions away. Thus, the inflow is split into a low salt "diluate flow" and a concentration flow (waste water). 24 RO permeate Concentration chamber Concentration chamber Concentration chamber Cathode Wastewater Anode Product water arium® 61215 EDI – Specifications Water Quality Achieved Conductivity (μS/cm)*: 0.2–0.07 Resistance (MΩ + cm)*: 5–15 TOC*: < 30 ppb Bacteria**: < 1 CFU/1000 ml Particles**: < 1/ml Specifications Feed Water Requirements Flow rate capacity (± 20% at 25°C)*: 15 l/hr Minimum inlet pressure: 1.2 bar Dimensions (W + H + D): 43 + 48 + 33.4 cm Maximum inlet pressure: 6.9 bar Empty weight: 20 kg Maximum conductance***: < 1000 μS/cm Operating weight: 25 kg Temperature: 5–35°C Power supply: 100–240 V AC, 50–60 Hz, single-phase Max. total hardness (max. CaCO3): 360 ppm Fouling index (SDI): <5 Free chlorine: 0.1 ppm Turbidity: < 1 NTU Iron (evaluated as total Fe content): < 0.1 ppm * Values may vary depending on the temperature and quality of the feed water and | or amount of impurities contained in the feed water. ** When using a Sartopore® 2 150 final filter *** In the absence of CO2 25 arium® 61316 Reverse Osmosis System The Sartorius Stedim Biotech arium® 61316 reverse osmosis system is the modern solution for reliable production of up to 16 l/hr ASTM type 3* water. Pure Water Quality for General Laboratory Applications The arium® 61316 reverse osmosis system is guaranteed to produce pure water for general laboratory applications thanks to a 99% rejection rate of ions, organic components, bacteria, and viruses. Common Areas of Application: – feed water for glassware machines, autoclaves, and air humidifiers – feed water for ultrapure water systems – rinsing of glass and laboratory containers – general laboratory applications * depending on feed water 26 Cost Effective Use of Technology The coarse contamination initially contained in the tap water is removed by the pretreatment cartridge to protect the delicate reverse osmosis module. The high performance membranes reliably produce good water quality and reduce water consumption. The modules are optimally protected from deposits via automatic membrane backflushing with permeate. Simple Data Access This device provides all information necessary for a pure water system. As with the EDI system, the arium® 61316 reverse osmosis system comes with professional menu navigation, enabling work to be structured in a convenient and user-friendly manner. The clear system information and text supported service functions make the device easy to understand and facilitates intuitive operation for the user. – display of conductance for feed water and product water – rejection rate as a % – tank fill level indicator – temperature in °C or °F 27 The arium® 61316 Reverse Osmosis System Step by Step Pretreatment Cartridge For Protection of the Reverse Osmosis Module In the first stage, coarse contamination is removed from the water to protect the reverse osmosis membrane. Pressure regulator Inlet Conductivity cell – activated carbon filter for the removal of chlorine and organic substances – 5 μm particle filter to prevent blockage of the module and to extend service life Pump Solenoid valve Reverse Osmosis Module For Effective Removal of Contamination Reverse osmosis removes all contamination to a certain degree. The reverse osmosis module filters out 98–99% of charged ions and 99% of all dissolved substances as well as particles and microorganisms. The constant flow rate also guarantees consistent crossflow of the membrane, ensuring optimal water purification. 28 Pretreatment cartridge RO module #1 Conductivity| Retention rate analysis Display The RO membranes are also rinsed with RO permeate to increase the service life of the module. Conductivity cell RO pressure tank RO module #2 Drain Conductivity Measurement For Controlling the Rejection Rate The integrated conductivity measuring cells measure feed water and product water to display the resulting rejection rate. Pressure Tank (30 l, 50 l, 70 l, and 100 l) Secure Storage of Water The completely sealed pressure tanks consist of an FDA-approved, double-butyl membrane capable of storing up to 100 l of pure water. Filling the tank creates an internal pressure of up to 2.5 bar. This removes the necessity for an additional pump for distributing the product water to the point of use. – reduction of contamination through microbes and gases – space-saving setup in desired locations – transfer of product water with up to 2.5 bar to the point of use 29 arium® 61316 – Specifications 30 Water Quality Achieved Rejection Rates Conductivity (μS/cm)*: < 20 Monovalent ions: up to 98% Resistance (MΩ + cm)*: > 0.05 Polyvalent ions: up to 99% Bacteria**: < 1 CFU/1000 ml Particles: > 99% Particles**: < 1/ml Microorganisms: > 99% Dissolved organic substances (MW > 300): > 99% Specifications Feed Water Requirements Flow rate capacity (± 20% at 25°C)*: 16 l/hr Minimum inlet pressure: 1.2 bar Dimensions (W + H + D): 43 + 48 + 33.4 cm Maximum inlet pressure: 6.9 bar Empty weight: 14 kg Maximum conductance: < 1500 μS/cm Operating weight: 20 kg Temperature: 5–35°C Power supply: 100–240 V AC, 50–60 Hz, single-phase Max. total hardness (max. CaCO3): 360 ppm Fouling index (SDI): <5 Free chlorine: 0.1 ppm Turbidity: < 1 NTU Iron (evaluated as total Fe content): < 0.1 ppm * Values may vary depending on the temperature and quality of the feed water and/or amount of impurities contained in the feed water. ** When using a Sartopore® 2 150 final filter 31 arium® 613L Reverse Osmosis System The Sartorius Stedim Biotech arium® 613L reverse osmosis system reliably produces ASTM type 3* water and is ideally suited for applications with high water consumption. The complete supply to buildings or individual floors is ensured centrally from roof or basement level. * depending on feed water 32 The arium® 613L reverse osmosis system can produce up to 300 l/hr and features an integrated 100 l tank as well as a transport pump capable of supplying different laboratories or several floors. Where larger water volumes are required, the optional tank systems (200 l, 600 l, or 1,000 l) offer a convenient solution. Different output points such as ultrapure water systems, laboratory devices, or direct output options can be connected effortlessly. – integrated pressure booster pump guarantees constant pressure and flow rate – permeate transport pump distributes the product water with up to 2 m3/h at 3.7 bar to the point of use Central Water System for Large Volumes of Pure Water The arium® 613L reverse osmosis system guarantees the removal of all contamination contained in tap water via the 5 μm particle filter to additionally protect the RO module. The systems have been specially developed for applications with a high daily requirement of RO water. In order to meet future increases in water consumption, the arium® 613L can be upgraded cost-effectively in increments of 50 liters per hour up to a total capacity of 300 l/hr. Common Areas of Application: – feed water for glassware machines, autoclaves, and air humidifiers – feed water for ultrapure water systems – general laboratory applications A B C D = Research and development = Scullery = HPLC laboratory = Cell culture laboratory 1 2 3 4 5 6 7 8 9 10 = arium® pro DI = Glassware machines I and II = Autoclaves I and II = Direct dispensing (faucet) = arium® pro UV = arium® pro UF = arium® pro VF = Autoclave = arium® pro VF = arium® pro VF 33 arium® 613L Reverse Osmosis System Specifications 34 Water Quality Achieved Rejection Rates Conductivity: < 20 μS/cm* Monovalent ions: up to 98% Resistance: Polyvalent ions: up to 99% Particles: > 99% Microorganisms: > 99% Dissolved organic substances (MW > 300): > 99% > 0.05 MΩ + cm* Specifications Flow rate capacity (± 20% at 25°C)*: 50, 100, 150, 200, 250, 300 l/hr Max. recovery rate*: approx. 40–80% Dimensions (W + H + D): 58 + 81 + 58 cm Systems 613L050 613L100 613L150 613L200 613L250 613L300 Capacity [l/h]** 50 100 150 200 250 300 Tank [l] 100 100 100 100 100 100 Electrical connection [V] 230 230 230 230 230 230 Power consumption [kW/h] 1.3 1.3 1.3 1.3 1.3 1.3 Power frequency [Hz] 50 50 50 50 50 50 Max. water temperature 25°C 25°C 25°C 25°C 25°C 25°C Max. inlet pressure 7 bar 7 bar 7 bar 7 bar 7 bar 7 bar Min. inlet pressure 2 bar 2 bar 2 bar 2 bar 2 bar 2 bar Weight (full) 150 kg 151 kg 152 kg 153 kg 154 kg 155 kg Bacteria (CFU/1000 ml) <1 <1 <1 <1 Number of membranes 1 2 3 4 5 6 * Depending on feed water quality and temperature ** Potable water quality at 10°C, 3 bar, max. 500 mg/l total salt content ± 5% flow rate 35 Intelligent Design: Flexibility in the Laboratory In terms of flexibility, the new arium® pro and basic series as well as the arium® 61215 EDI and arium® 61316 RO system leaves nothing to be desired. Individually adaptable to the laboratory conditions, the height adjustable displays allow space saving installation of the systems as benchtop, under-the-bench, or even wall-mounted systems. Benchtop Unit arium® benchtop units with head-side integrated display unit are an ideal, space saving solution for standard installation in the laboratory. The top-mounted head assembly enables optimal visibility of the display as well as an ideal position for operating the menu. arium® pro | basic systems are also equipped with integrated stowage space on the top of the system. The horizontal surface therefore provides additional space for accommodating sample containers or sampling chambers, for example. Below-bench Unit Space is a vital commodity in the laboratory. To ensure the highest degree of flexibility with limited space conditions, the systems can also be integrated into the laboratory furniture. The display and dispensing unit can be located up to 2.8 m from the device while still remaining convenient to use. 36 Wall mounted System A further space saving solution is the wall mounted version of the arium® devices. The supplied wall bracket enables the device to be easily positioned above the relevant work area. Thanks to the flexible installation options of the display with the dispensing unit, the operating comfort is maintained without restrictions. Remote Dispenser Accessory The arium® remote dispenser is the solution for greater flexibility in the laboratory. The arium® remote dispenser is an ergonomic, easy-to-handle dispensing unit which, thanks to its different designs, can be used for dispensing both pure and ultrapure water. The variants are available as benchtop units with stand foot or as a wall mounted system depending on space requirements. Thanks to the extended tube guide, the work area for dispensing is extended to up to three meters. Furthermore, the height adjustable stand foot enables optimal adjustment to different sizes of sampling chamber. The stand foot is also optionally available for the display | dispensing unit. Water Monitor Accessory The arium® water monitor provides additional security by identifying water leaks early and guaranteeing optimal protection in the laboratory. 37 Environmentally Friendly Use and Quality Assurance Environmentally Friendly Technology Eco Mode The arium® models have an automatic eco mode, whose start time can be set individually. The device goes into a standby mode to facilitate energy efficiency when not in use. Cartridges Thanks to the high performance cartridges inserted into the device combined with state-of-the-art technology, such as electronic|chemical deionization, the service life of the filters is increased considerably, which reduces environmental impact. Quality Assurance and Certification Our devices are subjected to constant quality controls during manufacture. The produced water quality is also rigorously tested with regard to observing international standards and regulations. This includes ensuring that the water complies with the following requirements: – ASTM, American Society for Testing and Materials – ISO 3696, International Organization for Standardization; Water for analytical laboratory use – Pharmacopeia, specified materials, including water for medical applications Overview of Regulations and Standards Regulation | arium® arium® Standard pro DI| pro UF basic ASTM type I + + ASTM type II + + ISO 3696 type I + + ISO 3696 type II + + NCCLS + + CAP + + Aqua purificata EU +**** +**** Aqua purificata USP +**** +**** Highly purified water EU* – + WFI EU** – – WFI USP*** – +**** arium® arium® 61316 61512 pro UV pro VF RO EDI + + + + + + +**** +**** – – – +*: depends on feed water quality WFI EU**: validation necessary, distillation necessary WFI USP***: validation necessary +****: validation necessary 38 + + + + + + +**** +**** + – +**** – – – +* +* +* +**** – – – – – + – + – – +**** +**** – – – Technical Service and Support Our application and service specialists undergo special training and understand our customers' applications, keeping in mind all legal requirements for the industry. Our employees have impressive experience in diverse sectors of the pharmaceutical | biotech, chemical, and food and drink industries in which the highest grade water is indispensable. First class service in installation, validation, and maintenance, as well as individual consultation are a standard for us. Take Advantage of the Range of Offers from Our Service Department – Needs analysis – Installation and startup – Technical support – Equipment qualification (IQ, OQ) and validation – Preventive maintenance service and service agreements – Corrective maintenance and spare part service – Customer specific user training For further information, visit www.sartorius-stedim.com/instrument-services 39 Ordering Information Order Number arium® pro Ultrapure arium® H20 pro Water Systems without TOC Monitor 40 Order Number arium® H20 pro with Integrated TOC Monitor Description H2Opro-DI-B – arium® pro DI wall-mounted system for producing ultrapure water for standard applications with front bottom-mounted display | dispenser unit and integrated wall bracket for the system H2Opro-DI-T – arium® pro DI benchtop system for producing ultrapure water for standard applications with front top-mounted display | dispenser unit H2Opro-DI-D – arium® pro DI built-in system for producing ultrapure water for standard applications, including wall-mounting kit for the display | dispenser unit that can be installed up to 2.8 meters from the system H2Opro-UF-B – arium® pro UF wall-mounted system for producing ultrapure water for cell culture applications with front bottom-mounted display | dispenser unit and integrated wall bracket for the system H2Opro-UF-T – arium® pro UF benchtop system for producing ultrapure water for cell culture applications with front top-mounted display | dispenser unit H2Opro-UF-D – arium® pro UF built-in system for producing ultrapure water for cell culture applications, including wall-mounting kit for the display | dispenser unit that can be installed up to 2.8 meters from the system H2Opro-UV-B H2Opro-UV-B-TOC arium® pro UV wall-mounted system for producing ultrapure water for chromato– graphy applications with front bottom-mounted display | dispenser unit and integrated wall bracket for the system H2Opro-UV-T H2Opro-UV-T-TOC arium® pro UV benchtop system for producing ultrapure water for chromato– graphy applications with front top-mounted display | dispenser unit H2Opro-UV-D H2Opro-UV-D-TOC arium® pro UV built-in system for producing ultrapure water for cell chromato– graphy applications, including wall-mounting kit for the display | dispenser unit that can be installed up to 2.8 meters from the system H2Opro-VF-B H2Opro-VF-B-TOC arium® pro VF wall-mounted system for producing ultrapure water for standard, cell culture, and chromatography applications with front bottom-mounted display | dispenser unit and integrated wall bracket for the system H2Opro-VF-T H2Opro-VF-T-TOC arium® pro VF benchtop system for producing ultrapure water for standard, cell culture, and chromatography applications with front top-mounted display | dispenser unit H2Opro-VF-D H2Opro-VF-D-TOC arium® pro UV built-in system for producing ultrapure water for standard, cell culture, and chromatography applications, including wall-mounting kit for the display | dispenser unit that can be installed up to 2.8 meters from the system arium® basic Ultrapure Water System Cartridge sets for arium® pro, arium® basic and arium® 611 systems Order Number Description H20 basic-B arium® basic wall-mounted system for producing ultrapure water for standard applications with front bottom-mounted display | dispenser unit and integrated wall bracket for the system H20 basic-T arium® basic benchtop system for producing ultrapure water for standard applications with front top-mounted display | dispenser unit Order Number Product Name Description H2O-A-PACK Analytical Kit Cartridge set for arium® VF or UV ultrapure water systems H2O-B-PACK Biological Kit Cartridge set for arium® UF ultrapure water systems H2O-E-PACK Elemental Kit Cartridge set for arium® basic and DI ultrapure water systems H2O-U-PACK Universal Kit * Cartridge set for arium® ultrapure water systems with tap water feed * Tap water cartridges should be used only after the feed water specifications have been checked and following consultation with the responsible Sartorius application specialist. 41 arium® pro Consumables Order Number Description 611CDU5 Ultrafilter 611CEL1 UV lamp 611CDS2 Sanitization kit (with 2 syringes) 611CDS6 Sanitization kit (with 6 syringes) 5441307H4--CE--B Sartopore® 2 150 sterile final filters, pore size: 0.2 μm (5 pcs.) arium® pro Accessories 42 Order Number Description H2Opro-AMDG1 Remote dispenser including height-adjustable stand foot H2Opro-AMDG2 Remote dispenser including wall mounting kit H2Opro-ADM1 Display mounting kit including height-adjustable stand foot 611APR1 Dot matrix printer for data logging 610AWGI Water monitor H2O-AFS1 Foot switch for water dispensing H2O-ALS1 Two level sensors for connection to an open tank system arium® 61215 Systems arium® 61215 Consumables arium® 61215 Accessories Order Number arium® 61215 Benchtop Unit Order Number arium® 61215 Built-in Unit Description 61215030F05M1A 61215030F05M1D Complete arium® EDI 61215 ASTM type 2 water system with 30-liter storage tank* (equipment supplied: arium® EDI 61215, water storage tank, 2+ reverse osmosis modules, 4+ softener cartridges, 2 pre-treatment cartridges + disinfection syringes for the reverse osmosis modules and water storage tank). 61215050F05M1A 61215050F05M1D Complete arium® EDI 61215 ASTM type 2 water system with 50-liter storage tank* (equipment supplied: arium® EDI 61215, water storage tank, 2+ reverse osmosis modules, 4+ softener cartridges, 2 pre-treatment cartridges + disinfection syringes for the reverse osmosis modules and water storage tank). 61215070F05M1A 61215070F05M1D Complete arium® EDI 61215 ASTM type 2 water system with 70-liter storage tank* (equipment supplied: arium® EDI 61215, water storage tank, 2+ reverse osmosis modules, 4+ softener cartridges, 2 pre-treatment cartridges + disinfection syringes for the reverse osmosis modules and water storage tank). 61215100F05M1A 61215100F05M1D Complete arium® EDI 61215 ASTM type 2 water system with 100-liter storage tank* (equipment supplied: arium® EDI 61215, water storage tank, 2+ reverse osmosis modules, 4+ softener cartridges, 2 pre-treatment cartridges + disinfection syringes for the reverse osmosis modules and water storage tank). Order Number Description 613CPF05-------V 2+ pre-treatment cartridges 612CPS1--------A 4+ softener cartridges 613CPM4-------V 2+ RO modules 611CDS2 Disinfection set for the tank (2 syringes) 612CDS2 Disinfection set for the RO modules (2 syringes) Order Number Description 613-AMDG1 Remote dispenser for 613APV pressure tank, including height-adjustable stand foot 613-AMDG2 Remote dispenser for 613APV pressure tank, including wall-mounting kit 613APV31 30-liter tank* 613APV50 50-liter tank* 613APV70 70-liter tank* 613APV100 100-liter tank* * With tank pressure of 2.5 bar 43 arium® 61316 Order Number Reverse Osmo- arium® 61316 Benchtop Unit sis System arium® 61316 Consumables arium® 61316 Accessories 44 Order Number arium® 61316 Built-in Unit Description 61316030F05M1A 61316030F05M1D Complete reverse osmosis system with a 30-liter storage tank* (equipment included: arium® 61316, water storage tank, 2+ reverse osmosis modules, 2 pre-treatment cartridges + disinfection syringes for the reverse osmosis modules and water storage tank). 61316050F05M1A 61316050F05M1D Complete reverse osmosis system with a 50-liter storage tank* (equipment included: arium® 61316, water storage tank, 2+ reverse osmosis modules, 2 pre-treatment cartridges + disinfection syringes for the reverse osmosis modules and water storage tank). 61316070F05M1A 61316070F05M1D Complete reverse osmosis system with a 70-liter storage tank* (equipment included: arium® 61316, water storage tank, 2+ reverse osmosis modules, 2 pre-treatment cartridges + disinfection syringes for the reverse osmosis modules and water storage tank). 61316100F05M1A 61316100F05M1D Complete reverse osmosis system with a 100-liter storage tank* (equipment included: arium® 61316, water storage tank, 2+ reverse osmosis modules, 2 pre-treatment cartridges + disinfection syringes for the reverse osmosis modules and water storage tank). Order Number Description 613CPF05-------V 2+ pre-treatment cartridges 613CPM4-------V 2+ RO modules 611CDS2 Disinfection set for the tank (2 syringes) 612CDS2 Disinfection set for the RO modules (2 syringes) Order Number Description 613-AMDG1 Remote dispenser for 613APV pressure tank, including height-adjustable stand foot 613-AMDG2 Remote dispenser for 613APV pressure tank, including wall-mounting kit 613APV31 30-liter tank* 613APV50 50-liter tank* 613APV70 70-liter tank* 613APV100 100-liter tank* * With tank pressure of 2.5 bar arium® 613L Reverse Osmosis System arium® 613L Consumables Order Number Description 613L050 Complete arium® RO system with distribution pump, 50 l/h, 230 Volt, 50 Hz, including 5 μm prefilter, RO membrane and 100-l tank 613L050D Complete arium® RO system without distribution pump (in conjunction with an external tank system) 50 l/h, 230 Volt, 50 Hz, including 5 μm prefilter, RO membrane 613L100 Complete arium® RO system with distribution pump, 100 l/h, 230 Volt, 50 Hz, including 5 μm prefilter, 2+ RO membranes and 100-l tank 613L100D Complete arium® RO system without distribution pump (in conjunction with an external tank system) 100 l/h, 230 Volt, 50 Hz, including 5 μm prefilter and 2+ RO membranes 613L150 Complete arium® RO system with distribution pump, 150 l/h, 230 Volt, 50 Hz, including 5 μm prefilter, 3+ RO membranes and 100-l tank 613L150D Complete arium® RO system without distribution pump (in conjunction with an external tank system) 150 l/h, 230 Volt, 50 Hz, including 5 μm prefilter and 3+ RO membranes 613L200 Complete arium® RO system with distribution pump, 200 l/h, 230 Volt, 50 Hz, including 5 μm prefilter, 4+ RO membranes and 100-l tank 613L200D Complete arium® RO system without distribution pump (in conjunction with an external tank system) 200 l/h, 230 Volt, 50 Hz, including 5 μm prefilter and 4+ RO membranes 613L250 Complete arium® RO system with distribution pump, 250 l/h, 230 Volt, 50 Hz, including 5 μm prefilter, 5+ RO membranes and 100-l tank 613L250D Complete arium® RO system without distribution pump (in conjunction with an external tank system) 250 l/h, 230 Volt, 50 Hz, including 5 μm prefilter and 5+ RO membranes 613L300 Complete arium® RO system with distribution pump, 300 l/h, 230 Volt, 50 Hz, including 5 μm prefilter, 6+ RO membranes and 100-l tank 613L300D Complete arium® RO system without distribution pump (in conjunction with an external tank system) 300 l/h, 230 Volt, 50 Hz, including 5 μm prefilter and 6+ RO membranes Order Number Description 613L-AE002 Conductivity meter 613L-AE002 UV lamp with housing 613L-CH001 5 µm prefilter 613L-CH002 RO membrane 45 arium® 613L Accessories Order Number Description 613AOV200 Standard 200-l tank with system-controlled distribution pump (for RO 613L050D, 613L100D, 613L150D, 613L200D, 613L250D, & 613L300D systems) 613AOV600 Standard 600-l tank with system-controlled distribution pump (for RO 613L050D, 613L100D, 613L150D, 613L200D, 613L250D, & 613L300D systems) 613AOV1000 Standard 1000-l tank with system-controlled distribution pump (for RO 613L050D, 613L100D, 613L150D, 613L200D, 613L250D, & 613L300D systems) arium® 615S Order Number Water Soften- 615S004 ing System arium® 615S Consumables 46 Description arium® 615S water softening system for up to 400 l, time-controlled regeneration and 25 kg salt, ready-to-use 615S006 arium® 615S water softening system for up to 600 l, time-controlled regeneration and 25 kg salt, ready-to-use 615S012 arium® 615S water softening system for up to 1200 l, time-controlled regeneration and 25 kg salt, ready-to-use Order Number Description 615SC001 25 kg salt tablets for regeneration arium® 615DI Complete Deionization Cartridges Order Number Description 615DI004 arium® complete deionization cartridge including hose connection set, capacity up to 420 l at 20° dH 615DI007 arium® complete deionization cartridge including hose connection set, capacity up to 650 l at 20° dH 615DI010 arium® complete deionization cartridge including hose connection set, capacity up to 1050 l at 20° dH 615DI014 arium® complete deionization cartridge including hose connection set, capacity up to 1400 l at 20° dH arium® 615DI Consumables Order Number Description 615DIC01 arium® refill pack for complete deionization cartridges, ion exchange resin mix in 25 l PE bag arium® 615DI Accessories Order Number Description 615ALC1 arium® conductivity analyzer for complete deionization cartridges with LED display (red > 20 µS/cm & green < 20 µS/cm) 615ADC1 arium® conductivity analyzer for complete deionization cartridges with digital measurement value display, conductivity measurement range 0.056–200 µS/cm 47 Application | System Overview arium® 61215 EDI arium® 61316 arium® 613L Feed water for glassware machines, autoclaves, air humidifiers ++ +++ +++ Feed water for ultrapure water systems + +++ +++ +++ +++ ++ ++ Application arium® pro DI | basic arium® pro UF arium® pro UV arium® pro VF General laboratory applications Rinsing of glass and laboratory containers ++ Steam generation +++ Preparation microbiological media and buffers +++ Reagent manufacture +++ +++ +++ +++ General media preparation ++ ++ ++ ++ ++ Biological applications Microbiology ++ +++ Molecular biology +++ Biotechnological applications: cell biology, biochemistry, genetics, DNA/RNA applications, medical diagnostics, tissue production, biomolecular procedures, biotech, and life sciences ++ +++ DNA sequence analysis +++ +++ IVF (in vitro fertilization) +++ +++ Cell culture media +++ +++ Protein | Enzyme manufacture + ++ Biochemical applications, general +++ + ++ Biochemical applications, PCR Drug discovery 48 +++ ++ +++ ++ ++ ++ ++ ++ arium® pro DI | basic arium® pro UF arium® pro UV arium® pro VF Inorganic analytical methods: IC, AAS, ICP, ICP-MS +++ ++ +++ ++ Electrochemistry +++ ++ +++ + Chromatography + + +++ +++ HPLC ++ ++ +++ +++ +++ +++ +++ Application arium® 61215 EDI arium® 61316 arium® 613L Analytical applications HPLC with low TOC content Analysis of trace elements (HPLC, IC, TOC) ++ ++ +++ Photometric methods: filter photometer, UV, UV-VIS Chromatography detectors ++ +++ +++ Mass spectrometry + + +++ Electrophoresis Film and gel technology + + +++ Electrophoresis + + ++ +++ Nanotechnology ++ ++ ++ ++ The table shows recommendations for various applications and can be used as a guideline. For help finding a device that meets your special requirements, please contact us directly. + = suitable to a limited extent ++ = suitable +++ = optimal 49 Sales and Service Contacts For further contacts, visit www.sartorius-stedim.com America Asia | Pacific Germany Sartorius Stedim Biotech GmbH August-Spindler-Strasse 11 37079 Goettingen Denmark Sartorius Stedim Nordic A/S Hoerskaetten 6D, 1. DK-2630 Taastrup USA Sartorius Stedim North America Inc. 5 Orville Drive Bohemia, NY 11716 Australia Sartorius Stedim Australia Pty. Ltd. Unit 5, 7-11 Rodeo Drive Dandenong South Vic 3175 Phone +49.551.308.0 Fax +49.551.308.3289 Phone +45.7023.4400 Fax +45.4630.4030 Toll-Free +1.800.368.7178 Fax +1.631.254.4253 Phone +61.3.8762.1800 Fax +61.3.8762.1828 Hungary Sartorius Stedim Hungária Kft Kagyló u. 5 2092 Budakeszi Sartorius Stedim SUS Inc. 1910 Mark Court Concord, CA 94520 China Sartorius Stedim Beijing Representative Office No. 33, Yu’an Road, Airport Industrial Zone B, Shunyi District Beijing 101300 www.sartorius-stedim.com Sartorius Stedim Systems GmbH Schwarzenberger Weg 73–79 34212 Melsungen Phone +49.5661.71.3400 Fax +49.5661.71.3702 www.sartorius-stedim.com France Sartorius Stedim Biotech S.A. ZI Les Paluds Avenue de Jouques – BP 1051 13781 Aubagne Cedex Phone +33.442.845600 Fax +33.442.845619 Sartorius Stedim France SAS ZI Les Paluds Avenue de Jouques – CS 71058 13781 Aubagne Cedex Phone +33.442.845600 Fax +33.442.846545 Austria Sartorius Stedim Austria GmbH Franzosengraben 12 A-1030 Vienna Phone +43.1.7965763.18 Fax +43.1.796576344 Belgium Sartorius Stedim Belgium N.V. Leuvensesteenweg, 248/B 1800 Vilvoorde Phone +32.2.756.06.80 Fax +32.2.756.06.81 Phone +36.23.457.227 Fax +36.23.457.147 Phone +1.925.689.6650 Toll Free +1.800.914.6644 Fax +1.925.689.6988 Italy Sartorius Stedim Italy S.p.A. Via dell’Antella, 76/A 50012 Antella-Bagno a Ripoli (FI) Sartorius Stedim Systems Inc. 201 South Ingram Mill Road Springfield, MO 65802 Phone +39.055.63.40.41 Fax +39.055.63.40.526 Phone +1.417.873.9636 Fax +1.417.873.9275 Phone +86.10.80426516 Fax +86.10.80426580 Sartorius Stedim Shanghai Represantative Office Room 618, Tower 1, German Centre, Shanghai, PRC., 201203 Phone +86.21.28986393 Fax +86.21.28986392.11 Netherlands Sartorius Stedim Netherlands B.V. Edisonbaan 24 3439 MN Nieuwegein Argentina Sartorius Argentina S.A. Int. A. Avalos 4251 B1605ECS Munro Buenos Aires Phone +31.30.6025080 Fax +31.30.6025099 Phone +54.11.4721.0505 Fax +54.11.4762.2333 Poland Sartorius Stedim Poland Sp. z o.o. ul. Wrzesinska 70 62-025 Kostrzyn Brazil Sartorius do Brasil Ltda Av. Dom Pedro I, 241 Bairro Vila Pires Santo André São Paulo Cep 09110-001 India Sartorius Stedim India Pvt. Ltd. #69/2-69/3, Jakkasandra Kunigal Road, Nelamangala Tq Bangalore – 562 123 Phone +55.11.4451.6226 Fax +55.11.4451.4369 Phone +91.80.4350.5361 Fax +91.80.4350.5253 Mexico Sartorius de México S.A. de C.V. Circuito Circunvalación Poniente No. 149 Ciudad Satélite 53100 Naucalpan, Estado de México Japan Sartorius Stedim Japan K.K. KY Building, 8–11 Kita Shinagawa 1-chome Shinagawa-ku Tokyo 140-0001 Phone +48.61.647.38.40 Fax +48.61.879.25.04 Spain Sartorius Stedim Spain SA C/Isabel Colbrand 10, Oficina 70 Polígono Industrial de Fuencarral 28050 Madrid Phone +34.90.2110935 Fax +34.91.3589623 Switzerland Sartorius Stedim Switzerland AG Ringstr. 24 a 8317 Tagelswangen Phone +41.52.354.36.36 Fax +41.52.354.36.46 U.K. Sartorius Stedim UK Limited Longmead Business Park Blenheim Road, Epsom Surrey KT19 9 QQ Phone +44.1372.737159 Fax +44.1372.726171 Phone +52.5555.62.1102 Fax +52.5555.62.2942 Sartorius Stedim Guangzhou Office Room 704, Broadway Plaza, No. 233–234 Dong Feng West Road Guangzhou 510180 Phone +86.20.8351.7921 Fax +86.20.8351.7931 Phone +81.3.3740.5407 Fax +81.3.3740.5406 Malaysia Sartorius Stedim Malaysia Sdn. Bhd. Lot L3-E-3B, Enterprise 4 Technology Park Malaysia Bukit Jalil 57000 Kuala Lumpur Phone +60.3.8996.0622 Fax +60.3.8996.0755 Singapore Sartorius Stedim Singapore Pte. Ltd. 1 Science Park Road, The Capricorn, #05-08A, Singapore Science Park 2 Singapore 117528 Phone +65.6872.3966 Fax +65.6778.2494 Specifications subject to change without notice. Printed in Germany on paper that has been bleached without any use of chlorine. | W Publication No.: XX-0000-e07051 · Order No.: 00000-000-00 · Ver. MM | YYYY Europe Type 1 Water Ma chr nufa c pho omat ture tom ogr of r etr aphy eage ic m , H nt eth PLC s, ele ods , an ctr , m aly och ass sis o em spe f tr istr ctr ace y, om etr elem y ent s, Preparation of buffers and media, manufacture of reagents, rinsing of glass vessels, inorganic analytical methods: IC, AAS, ICP, ICP-MS, electrochemistry Manufacture of reagents, molecular biology, RNA | DNA purification, DNA sequence analysis, IVF, cell culture media, PCR, chromatography, HPLC, analysis of trace elements, electrophoresis arium pro VF ® I ED 15 2 61 – – 615DI cartridges – r ne fte o S 5S al at 61 ption H) (o 0° d >2 I D 615 16 or 615S RO 613 DI Softener l 5 1 612 E (optiona dH) ° 0 2 at > 16 ) 613atory O R lig (ob UV pro m® RO E DI DI r ate W p I ca rtri dge Soft s (opt ener 6 i 1 at > onal 5S 20° RO 6 dH) 6121 1316 o 5 ED r I – 615 D – Ty p e T – ate r e yp ari u DI Tap W 2 arium® pro DI arium® basic r Tap Wate RO EDI R ED O I Ta Type 3 Reverse osmosis systems 61316 (16 l/h) 613L (50–300 l/h) RO Type 3 r ate pW r Tap Wate RO DI 3W a t er 61215 EDI system (15 l/h) So 61 ftene (op 5S r >26 tiona ° dH l at ) 6 Type 2 Ta r 6o 31 DI 1 6 E trid RO 215 car 1 S I 6 15 5D 61 r6 e n l ) fte na H So ptio 0° d (o t >2 a s ge p W ate r ter Wa UF 31 – arium® pro (1.7–2 l/min) um ari pro 61 – Type 1 ® L or 615S RO 61316 I Softener l D E 5 1 612 (optiona dH) at >20° 613 615DI cartridges – DI – Ta RO EDI Your System – S 6 oft (o 15S ener > pt 2 0° iona dH l a ) t Wa t er Fee as d wa fee air hu ter fo gla d wa midif r diff t s s and er fo iers, a erent lab r ult uto labo o r a ra- clav rat p t o ry v ure w es, g ory e la q ess e ate ssw uip l s , st r syst are m ment eam em ach , suc g s; h i n r e n era insin es; tio g o n f Recommended Pre-treatment , on) ati z i l ti fer itro ical v n m F (i he , IV l bioc ods s i s h t ly ra ana ene me ce ia, g etric n e d m equ me to Your A s lture s, pho DNApplications u n lc io cel licat app RO Ty p e1 Your Required ASTM Water Quality Turn the disk to the water quality and applications you require and see which system meets your requirements. You can also view the recommended pre-treatments. Your Feed Water Type 1 Water pe ter y tor ora ater rs b a w rl ffe r fo -pure cal bu e t wa ltra logi eed for u robio nts f , r ic age ion te rat d wa of m of re e n ge fee tion ure am nt, ara act Ste ipme , prep anuf equ tems ia, m sys med and Ty a 1W Softener 615S Deionization cartridges 615DI Type 1 Water Pre ma para ves nufa tion o IC, sels, cture f buf AA ino of f S, I rga rea ers a CP nic ge nd , IC n m P-M analy ts, ri edia S, e tica nsing , lec l me of tro che thods glass mis : try arYour ium ® System pro VF RO 6 L 13 16 613 Ma RN nufa c IVF A | D ture HP , cell NA pu of re a LC, cul ana tur rifica gents lysi e m tion , mo s o edia , DN lec f tr u ace , PCR A seq lar b ele , chr uen iolo me om ce gy, nts ato an a , el ect graph lysis, rop y, hor esi s Softener 615S (optional at >20° dH) Type 3 ener Soft 5 61 Sional at (opt ° dH) >20 – RO DI 61215 E 615DI RO 61316 (obligatory) I ca rtri dge Soft s (opt ener 6 i 1 at > onal 5S 20° RO 6 dH) 6121 1316 o 5 ED r I – Ta – 61215 EDI system (15 l/h) Type 3 615 D – r ate W p T – RO E DI DI 3 UV ari u ari m ® p um ® ro bas DI ic r Tap Wate DI arium® pro (1.7–2 l/min) pro RO Type 2 ate r e yp r 6o 31 DI 1 6 E trid RO 215 car 1 S I 6 15 5D 61 r6 e n l ) fte na H So ptio 0° d (o t >2 a s ge Tap W Type 1 m riu a R ED O I – ® Tap Water or S RO 61316 DI E 5 1 2 1 6 615 Softener l (optiona dH) at >20° – DNA sequence analysis, IVF (in vitro fertilization), cell culture media, general biochemical applications, photometric methods arium® pro UF 615DI cartridges r ne t fte So 5S nal a 61 ptio H) (o 6° d >2 RO EDI Steam generation, feed water for laboratory equipment, feed water for ultra-pure water systems, preparation of microbiological buffers and media, manufacture of reagents R ED O I DI Wa t er ate r Ty p e1 Tap W 615 ts, , try emen s i em el och ace ctr of tr etry e l is m ,e nts alys ctro age C, an s spe e r s f HPL ma eo tur aphy, hods, c a f Your nu atogr c met MaApplications m etri o r ch tom o ph ter Wa – – ter Wa Wa t er T ap – DI car trid Soft Recommended ges e (opt ner 6 Pre-treatment i 1 o 5 at > nal S 20° RO 6 dH) 6121 1316 o 5 ED r I – DI Your Required ASTM Water Quality Turn the disk to the water quality and applications you require and see which system meets your requirements. You can also view the recommended pre-treatments. Your Feed Water Type 2 Water 1 h suc nt, es; e ipm hin f equ e mac sing o y r r ato wa ; rin n bor glass stems ratio a l e t s, y ren ave er s gen iffe utocl wat eam d r a ure s, st p l r fo rs, ate idifie ultra- vesse w y d m r r e u o o Fe air h ter f rat as d wa d labo fee ss an gla T e yp Ty p e1 ter Wa Reverse osmosis systems 61316 (16 l/h) 613L (50–300 l/h) Softener 615S Deionization cartridges 615DI Type 1 Water Tap W Ste equ am g sys ipme enera and tems nt, f tion me , pre eed w , feed dia par , m atio ater wate fo anu n r fac of m r ultr for la tur icr a-p bo e o obi ur rat f re olo e w ory age gic ate nts al b r uff e rs R ED O I DI Wa t er ate r Ty p e2 RO EDI VF 6 or 615S RO 6131DI E Softener l 5 1 2 1 6 (optiona dH) at >20° DI pro ic um as ari m® b u ari RO 613L 612 Type 3 Softener 615S (optional at >26° dH) Soften e 615S r (option >20° d al at H) Type 3 Type 2 RO 61316 I 5D – So 615 ftene (op S r >2 tiona 0° dH l at ) Ta – – s ge DN cel A seq app l cult uenc lica ure e an tio med aly ns, s pho ia, ge is, IVF tom nera (in etr l bi vitr ic m och o f eth emi ertili ods cal zat ion ), Tap W r ate W p 61 or 16 I 3 61 ED trid RO 1215 car S I 6 5 5D 61 61 er l ) n e a ft n H So ptio 0° d (o t >2 a 15 E D I ® RO (ob 613 liga 16 tor y) RO E DI DI – Type 1 Manufacture of reagents, electrochemistry, chromatography, HPLC, analysis of trace elements, photometric methods, mass spectrometry y, log sis, bio analy , ar cul ce phy is ole uen ogra hores t , m eq nts A s oma trop age , DN chr elec f re ion R, ts, e o cat , PC en tur purifi edia elem fac nu NA re m race Ma A | D cultu s of t RN , cell alysi IVF LC, an HP – r pro s las a, edi of g m : g nd sin ods y r rs a rin th ffe ents, al me emist u b ag tic h f c o f re aly ctro on ati ure o nic an , ele r a S t p a Your c Pre nufa inorg ICP-M a ls, , P mApplications C e I s ves AAS, IC, arium® pro UV 615DI cartridges ate ® um ari arYour ium ® System pro UF 1W 615 pe – – r Tap Wate Wa t er Ty r 6o s 31 I ge 61 ED rid RO 1215 art S Ic 6 15 5D 61 r6 ne l ) fte na H So ptio 0° d (o t >2 a – DI car trid Recommended Soft ges (opt ener 6Pre-treatment 1 i at > onal 5S 20° RO 6 dH) 6121 1316 o 5 ED r I – DI Your Required ASTM Water Quality – r ate W p Ty p e1 Turn the disk to the water quality and applications you require and see which system meets your requirements. You can also view the recommended pre-treatments. Your Feed Water RO ate r Tap Water Type 3 Water RO EDI DI – Ta 1 Feed water for different laboratory equipment, such as air humidifiers, autoclaves, glassware machines; feed water for ultra-pure water systems; rinsing of glass and laboratory vessels, steam generation T e yp ter Wa arium® pro (1.7–2 l/min) 61215 EDI system (15 l/h) Reverse osmosis systems 61316 (16 l/h) 613L (50–300 l/h) Softener 615S Deionization cartridges 615DI Type 1 Water Fee as d wa fee air hu ter fo gla d wa midif r diff ss a ter e ie nd for rs, au rent l a lab ult r ora a- toclav borat tor pur es, ory y v e w gla eq ess els ater s sswar uipm , st e eam ystem e ma nt, su gen s; rin chine ch era sin s; tio g o n f 6 L 31 613 RO RO 61 R ED O I Wa t er DI ate r Tap W So 615ftener (op S >26 tiona ° dH l at ) Ta S 6 oft (o 15S ener >2 ptio 0° na dH l a ) t Ta r ate W p Ma chr nufa c pho omat ture tom ogr of r etr aphy eage ic m , H nt eth PLC s, ele ods , an ctr , m aly och ass sis o em spe f tr istr ctr ace y, om etr elem y ent s, Type 3 Reverse osmosis systems 61316 (16 l/h) 613L (50–300 l/h) Softener 615S Deionization cartridges 615DI Type 1 Water RO r p W ate r 61215 EDI system (15 l/h) Type 3 Manufacture of reagents, molecular biology, RNA | DNA purification, DNA sequence analysis, IVF, cell culture media, PCR, chromatography, HPLC, analysis of trace elements, electrophoresis – Type 2 ate 21 61 16 ) 613atory O R lig (ob r ne fte So 5S al at 61 ption H) (o 0° d >2 I D 5E ), ion zat tili fer itro al n v mic F (i he , IV ioc ds ysis al b etho nal ner e a , ge ric m enc dia met equ me to A s ure pho DN l cult ions, cel licat app – DI 615 1W – arium® pro (1.7–2 l/min) UF or 615S RO 61316 I Softener l D E 5 1 612 (optiona dH) at >20° Type 1 Preparation of buffers and media, manufacture of reagents, rinsing of glass vessels, inorganic analytical methods: IC, AAS, ICP, ICP-MS, electrochemistry arium® pro DI arium® basic 615DI cartridges pe pro – Ty ® um arYour ium ® System pro UV ory rat bo ater fers a l w r f r fo ure l bu ate tra-p ogica w ed r ul biol ts n o , fe fo on ater micr reage i t ra d w of of e n n e ge fe tio ure am nt, ara act Your Ste ipme , prep anuf u s m eqApplications tem ia, sys med and arium® pro VF 615 ari RO EDI Wa t er – – DI car trid Soft Recommended ges e (opt ner 6 Pre-treatment i 1 o 5 at > nal S 20° RO 6 dH) 6121 1316 o 5 ED r I – DI Ty p e1 RO EDI Your Required ASTM Water Quality – 615DI cartridges or 615S RO 61316 I Softener l D 61215 E (optiona dH) at >20° – – r 6o 31 I s ge 61 ED rid RO 215 art S Ic 61 15 5D 61 r6 ne l ) fte na H So ptio 0° d (o t >2 a Ty p e3 RO EDI DI Turn the disk to the water quality and applications you require and see which system meets your requirements. You can also view the recommended pre-treatments. Your Feed Water r Tap Wate r Tap Wate – r ate W 2 pe DI Ty r ate W p Ta Type 2 Water T 3 RO EDI DI DI RO EDI Tap W Your Required ASTM Water Quality Ty p e1 ate r – – 615 D I car trid Sof ges (op tener 6 at >tional 15S 20° d H) Wa t er DI R ED O I R ED O I DI ate r Tap W Type 1 Water 3L 61 Ty p e Type 3 1W a t er Ta r Pre ma para ves nufa tion o IC, sels, cture f buf AA ino of f S, I rga rea ers a CP nic ge nd , IC n m P-M analy ts, ri edia S, e tica nsing , lec l me of tro che thods glass mis : try , y, nts istr leme hem e e roc f trac ry t ect , el is o me nts alys ctro age , an spe f re HPLC ass m eo tur aphy, hods, fac et nu ogr Ma omat etric m chr tom pho r ate W p ate RO pe Tap Water Ty VF 16 613 DNA sequence analysis, IVF (in vitro fertilization), cell culture media, general biochemical applications, photometric methods 61215 EDI system (15 l/h) pro DI 61215 E RO Type 2 ium ® Steam generation, feed water for laboratory equipment, feed water for ultra-pure water systems, preparation of microbiological buffers and media, manufacture of reagents Ma RN nufa c IVF A | D ture HP , cell NA pu of re a LC, cul an tu rifica gent a l ysis re me tion, s, mo of dia, DNA lecu t r a ce PCR, sequ lar bio ele chr me om ence logy, n t s, e atog analy lec rap sis, tr hy o p hor , esi s arium® pro (1.7–2 l/min) r ne t fte So 5S nal a 61 ptio H) (o 6° d >2 h suc nt, es; e ipm hin f equ e mac sing o y r r ato wa ; rin n bor glass stems ratio a l e t s, y ren ave er s gen iffe utocl wat eam d r a ure s, st p l r fo rs, ate idifie ultra- vesse w y d m r Your r e u o o Fe air h ter f rat a bo asApplications d w d la fee ss an gla 615DI RO ener Soft 5 61 Sional at (opt ° dH) >20 Type 1 ari um ® System arYour ium ® pro bas DI ic UV – pro Softener 615S (optional at >20° dH) ® RO 61316 (obligatory) um – ari DI car trid Soft Recommended ges e (opt ner 6 Pre-treatment i 1 o 5 at > nal S 20° RO 6 dH) 6121 1316 o 5 ED r I – – 615 ar Your Feed Water – – RO 6 6121 1316 o 5 ED r I – arium® pro UF r 6o 31 I s ge 61 ED rid RO 215 art S Ic 61 15 5D 61 r6 ne l ) fte na H So ptio 0° d (o t >2 a Turn the disk to the water quality and applications you require and see which system meets your requirements. You can also view the recommended pre-treatments. 1W 615DI cartridges 316 or 615S RO 61 EDI Softener l 61215 (optiona dH) at >20° – r ate W p r Tap Wate – Ta e yp ter Wa Type 3 Reverse osmosis systems 61316 (16 l/h) 613L (50–300 l/h) Softener 615S Deionization cartridges 615DI Type 3 Water DI R ED O I um ® pro VF Type 3 pe 1W ate ate r y, log sis, bio analy , ar cul ce phy is ole uen ogra hores t , m eq nts A s oma trop age , DN chr elec f re ion R, ts, e o cat , PC en tur purifi edia elem fac nu NA re m race Ma A | D cultu s of t RN , cell alysi IVF LC, an HP r Reverse osmosis systems 61316 (16 l/h) 613L (50–300 l/h) Softener 615S Ty Tap W r 6o s 31 I ge 61 ED rid RO 1215 art S Ic 6 15 5D 61 r6 ne l ) fte na H So ptio 0° d (o t >2 a ari Ty p e 61215 EDI system (15 l/h) 1W a t er , ass dia f gl o me : nd sing ods y r rs a rin th ffe ents, al me emist bu of reag alytic troch f c on ati re o c an , ele S par ctu ani Pre nufa inorg ICP-M ma sels, ICP, ves AAS, IC, Type 3 Manufacture of reagents, electrochemistry, chromatography, HPLC, analysis of trace elements, photometric methods, mass spectrometry DN cel A seq app l cult uenc lica ure e an m a t i o ns, edia lysis, pho , ge IVF to ne (i n m etr ral bi vitr ic m och o f e e tho emic rtiliz ati ds al on) , Type 2 Ste equ am g sys ipme enera and tems nt, f tion me , pre eed w , feed dia par , m atio ater wate fo anu n r fac of m r ultr for la tur icr a-p bo e o obi ur rat f re olo e w ory age gic ate nts al b r uff ers Deionization cartridges 615DI Type 1 Water Feed water for different laboratory equipment, such as air humidifiers, autoclaves, glassware machines; feed water for ultra-pure water systems; rinsing of glass and laboratory vessels, steam generation RO 613L Softener 615S (optional at >26° dH) RO EDI DI RO 61316 Your Applications r ate 1W pe DI Ty r ate pW 15 E – ari um ® 612 – RO 6 6121 1316 o 5 ED r I 5 UF 61 DI System Your pro ) Soften e 615S r (option >20° d al at H) arium® pro (1.7–2 l/min) Wa t er Ta 615 D I car trid Sof ges (op tener 6 at >tional 15S 20° dH) RO – – ory I oD ® pr c um asi ari m® b u ari – arium® pro UV r 6o s 31 I ge 61 ED rid RO 1215 art S Ic 6 15 5D 61 r6 ne l ) fte na H So ptio 0° d (o t >2 a – So Your Feed 615 ftene Water (op S r RO >2 tiona Recommended (ob 613 0° dH l aPre-treatment liga 16 t ) t Tap Water ate r – Tap W Your Required ASTM Water Quality Ty p e2 – RO EDI Turn the disk to the water quality and applications you require and see which system meets your requirements. You can also view the recommended pre-treatments. – Type 1 DI 615DI cartridges 6 or 615S RO 6131DI Softener l 61215 E (optiona dH) at >20° – – Ta r ate W p RO EDI DI r Tap Wate The arium® Family at a Glance Sartorius Stedim Biotech GmbH August-Spindler-Strasse 11 37079 Goettingen, Germany Phone +49.551.308.0 Fax +49.551.308.3289 www.sartorius-stedim.com Specifications subject to change without notice. Printed in Germany on paper that has been bleached without any use of chlorine. | W Publication no.: SL-1531-e11092 Order no.: 85032-537-71 Ver. 09 | 2011
Similar documents
arium® pro Ultrapure Water Systems
Analogous to the arium® pro DI, the arium® pro UV uses not only 3-step purification technology, but also the removal of organic matter by means of photo-oxidation. With two different wavelengths, t...
More information