A Profile of Sartorius Stedim Biotech
Sartorius Stedim Biotech is a leading provider of cutting edge equipment and services for the
development, quality assurance and production processes of the biopharmaceutical industry.
Its integrated solutions covering fermentation, filtration, purification, fluid management
and lab technologies support the biopharmaceutical industry around the world to develop
and produce drugs safely, timely and economically.
Sartorius Stedim Biotech focuses on single-use
technologies and value added services to meet the
rapidly changing technology requirements of the
industry it serves. Strongly rooted in the scientific
community and closely allied with customers and
technology partners, the company is dedicated to
its philosophy of turning science into solutions.
Headquartered in Aubagne, France, Sartorius Stedim
Biotech is listed on the Eurolist of Euronext Paris.
With its own manufacturing and R&D sites in Europe,
North America and Asia and a global network of
sales companies, Sartorius Stedim Biotech enjoys
a worldwide presence. Its key manufacturing and
R&D site is in Germany.
2
Contents
The Benefits of
the arium® Family
at a Glance
arium® basic –
A Cost Effective
Alternative
arium® 61316
Reverse Osmosis
System
Page 5
Page 16
Page 26
Environmentally Friendly
Use and Quality
Assurance
Page 38
Solutions for Any
Application –
Overview of the
Systems
Page 6
arium® pro and
basic –
Equipment and
Specifications
The arium
61316 Reverse
Osmosis System
Step by Step
Technical
Service and
Support
Page 18
Page 28
Page 39
arium® pro
Ultrapure Water
Systems for Critical
Applications
arium® EDI
61215 – ASTM
Type 2 Pure
Water System
Page 8
Page 20
Optimal
Purification with
the arium® pro
Family
arium® 61215
EDI System
Design
Page 10
Reliable Water
Quality
Page 12
Work without
Compromise with
the arium® pro
Family
Page 14
®
arium® 61316
– Specifications
Page 30
Ordering
Information
Page 40
arium® 613L
Reverse Osmosis
System
Application |
System
Overview
Page 22
Page 32
Page 48
Functionality of
EDI Technology
arium® 613L
Reverse Osmosis
System
Specifications
Page 24
arium®
61215 EDI –
Specifications
Page 25
Page 34
Intelligent
Design:
Flexibility in the
Laboratory
Page 36
3
In the biopharmaceutical industry,
universities, and clinical institutes, it is
increasingly important for our customers to
use laboratory grade water for the various
applications. More demanding requirements
and increasingly sensitive analysis equipment set a benchmark to reach the required
standard of high quality water.
However, with the range of purification
technology available, it can often be
difficult to select the right equipment to
achieve the necessary water quality for
your application. The feed water is also
an important consideration.
4
The product overview on the rotary disk
should help you find the right device
for your applications. It also indicates
recommended pre-treatment depending on
the feed water. The disk provides a general
first impression of the arium® family and
how it can meet all of your scientific
laboratory requirements, taking you from
feed water through to ultrapure water.
Of course, our specialists are also on hand
for individual consultation.
ASTM type 1, type 2 or type 3 – Sartorius
Stedim Biotech has the right device
depending on the application and required
water quality. This brochure gives an
overview of all water systems with a focus
on the new, upgraded versions of our
ultrapure water systems: the arium® pro
product line offerings.
The Benefits of the
arium® Family at a Glance
All arium® systems are developed
by experts, combining know-how
with the highest quality
standards. The arium® family has
standardized features that make
working with the devices as
simple and efficient as possible.
A Higher Standard of Quality
The efficient removal of all
possible contamination guarantees
consistent water quality for
optimal and reliable results in
any application.
Cost Effective and
Environmentally Friendly
Components and materials in the cartridges
have been designed to complement each
other resulting in a long service life and
optimal purification making these units
highly cost effective.
Easy to Use
All necessary information can be
accessed instantly and easily on
the practical touch display.
Maximum Flexibility
The diverse options for configuring the
arium® systems in your laboratory based
on your individual requirements means
optimal flexibility during work and when
dispensing water.
5
Solutions for Any Application –
Overview of the Systems
Sartorius Stedim Biotech offers the right solution for every application and its required
water quality, from the pretreatment of feed water in order to allow for efficient use of
downstream cleaning steps, to the required polished product water.
Type 1 Water Quality
The newly developed arium® pro range produces
ultrapure water for critical applications. There are four
different systems to choose from depending upon your
individual requirements. The systems are available both
with and without an integrated TOC monitor. In addition,
there is also the arium® basic model, a streamlined, cost
effective alternative to the arium® pro DI with the most
important product features.
arium® pro DI
arium® pro UV
arium® pro UF
arium® pro VF
arium® basic
Type 2 Water Quality
For the production of ASTM type 2* water quality,
Sartorius Stedim Biotech offers the arium® 61215
EDI system for general applications. An alternative to this system is the arium® 615DI cartridges,
which produce type 2* water when used for the
secondary treatment of reverse osmosis water.
arium® 61215 EDI
arium® 615DI
* depending on feed water
6
Water Softening for Pretreating
Water for arium® RO and EDI Systems
For particularly hard water, we recommend the arium® 615S water softener,
used to pretreat the water in order to
protect the device cartridges.
arium® 615S**
Complete Deionization Cartridges
for Pretreating Water for arium® pro
Systems
For saline water, we recommend the
arium® 615DI deionization cartridges,
used to produce completely deionized
water as pretreatment for arium® pro
ultrapure water systems.
arium® 615DI**
** For further information, request the data
sheets for these products.
Type 3 Water Quality
The arium® reverse osmosis systems produces
ASTM type 3* water quality. These systems
are designed to meet water requirements
for general laboratory applications, such as
cleaning and rinsing laboratory equipment,
as well as for water supplied to an entire
building.
arium® 61316 – produces up to 16 l/hr
arium® 613L – produces up to 50–300 l/hr
* depending on feed water
7
arium® pro Ultrapure Water Systems for Critical Applications
The new Sartorius Stedim Biotech arium® pro ultrapure water
systems reliably produces ASTM type 1 water (18.2 MΩ)
and fulfill all requirements for reagent grade water for critical
and routine applications.
1 Cartridge Sets
For Producing Ultrapure Water
In ultrapure water systems, cartridge sets comprising a pretreatment and
secondary treatment cartridge. The cartridges are designed for optimal crossflow
of resins. The flow of water moves from the top to the bottom of the cartridges
to achieve optimal cleaning motion and to prevent the medium inside the
cartridges from mixing.
– contain granulated, catalytically-active, activated carbon of the highest quality
– contain high efficient mixed-bed ion exchange resins
– have the highest ion exchange capacity available in the industry and reduce
operating costs
2 Dual Wavelenght UV Lamp (185 | 254 nm)
For Removing Organic Substances
The UV lamp reliably removes organic substances
(TOC or total organic carbon), effectively preventing
bacterial growth. TOC content can also be monitored
with an optional integrated TOC monitor in the
arium® pro.
8
3 Ultrafilter
For Removing Macromolecules
The ultrafilter separates bacterial endotoxins, pyrogens,
DNA and RNA. The single-use, hollow-fiber ultrafilter
achieves high flow rates and has a low adhesion to
leachable substances.
2
3
4 Sterile Final Filter Sartopore® 2 150
Membrane Filter Capsules
The Sartopore® 2 150 membrane filter provides additional protection from particles
and bacteria and impresses with its constant flow rate. The 0.45 + 0.2 μm polyether
sulfone double membrane guarantees microbiological retention in compliance with
HIMA and ASTM guidelines for sterile filters and is therefore particularly suited for
critical applications.
8
7
6
5
4
5 Display
For Complete Control
The newly developed display with glass interface and touch screen
function is simple to use with the integrated text support. All
necessary information can be accessed instantly. A range of basic
settings can be restricted to authorized users only by entering
a PIN code. Colored warning and system messages provide modern
convenience in day-to-day handling of the device.
1
6 Water Dispensing
Manual, Volume, and Time Control
The slider on the display enables continuous manual water
dispensing, during which the flow rate can be freely regulated
between 0.5 and 2 l/min. The volume and time controlled
dispensing facilitates precise proportioning and avoids
waiting for water to be dispensed.
7 Conductivity Measurement
In Feed Water and Product Water
Measurement of both conductance values
help prevents rapid wear of cartridge sets,
where applicable.
8 Electronic Connections
For Data Storage
The newly developed arium® pro features various electronic connections
and particularly stands out with its modern data storage option via
SD card. It also has the option of transferring data to a printer or
via a PC using an RS-232 serial interface.
9
Optimal Purification with the arium® pro Family
The new arium® pro range comprises of four different models that can be specially customized to
our customers' requirements. It provides optimal water quality for reliable analyses.
arium® pro DI
This standard system of the arium® pro range contains a cartridge
set and sterile filter. The cartridge set is selected individually based
on the feed water quality and intended application and comprises
a pretreatment cartridge followed by a secondary treatment
cartridge. All cartridges use patented Sartorius technology
for the creation of ultrapure water that exceeds ASTM criteria
for type 1* reagent grade water.
Applications:
– buffer and media production
– reagent manufacture
– rinsing of glass containers
– inorganic analytical methods:
IC, AAS, ICP, ICP-M
arium® pro UV (with Optional TOC Monitor)
Besides the purification cartridges, the arium® UV device also
has a 185 | 254 nm dual wavelenght UV lamp to reliably remove
organic substances (TOC). At the same time, the UV radiation
inactivates microbial cells via the adsorption of the UV light.
This facilitates a sterilized production of ultrapure water.
Applications:
– chromatography
– standard HPLC
– analysis of trace elements
10
– photometric methods
– reagent manufacture
– mass spectrometry
* depending on feed water
arium® pro UF
The arium® UF contains an ultrafilter for removing
endotoxins, pyrogens, DNA, and RNA. A 5,000 MWCO
(5 kDa) microporous membrane removes macromolecules from the water so that an endotoxin level of
< 0.001 EU/ml is achieved.
Applications:
– cell cultivation
– DNA sequence analysis
– IVF (in vitro fertilization)
– general biochemical applications
arium® pro VF (with Optional TOC Monitor)
The arium® VF model combines the UV lamp and
the ultrafilter in one device to produce water for
particularly critical standards, cell cultivation,
and chromatography applications.
Applications:
– chromatography
– electrophoresis
– HPLC
– IVF
– molecular biology
– cell cultivation
– RNA|DNA purification
– reagent manufacture
– PCR
11
Reliable Water Quality
The arium® pro range produces laboratory grade water that meets the ASTM type 1* standard.
With 18.2 MΩ + cm as well as the lowest TOC and endotoxin levels, optimal reliability in
applications is guaranteed.
Product Water Quality
pro DI
pro UV
pro UF
pro VF
Specific resistance (MO + cm)
18.2
18.2
18.2
18.2
TOC content (ppb)1 @ 25 °C
<5
<2
<5
<2
Endotoxins (EU/ml)
N/A
N/A
< 0.001
< 0.001
Particles (at 0.2 μm)
< 1/ml
< 1/ml
< 1/ml
< 1/ml
Bacteria (CFU/1000 ml)
<1
<1
<1
<1
up to 2
up to 2
up to 1.7
up to 1.7
2
Flow rate (l/min)
N/A = not applicable
1 Values may vary depending on the quality of the feed water and the content of impurities in the feed water,
as well as the type of cartridge used.
2 At a pressure of 2 bar, without final filter
Ultrapure Water for Critical
Applications
The arium® pro VF model produces
RNase free and DNase free water
with a TOC content of 1–2 and an
endotoxin value of < 0.001 EU/ml.
12
arium® pro VF*
Laboratory Grade Ultrapure
Water
The diagram illustrates how
water quality fluctuates
in freshly prepared ultrapure
water. Only ultrapure water
without peaks, like that
produced with the arium® pro
VF, guarantees the highest
grade water for stringent
requirements.
Competitor A*
* HPLC application (reverse-phase chromatography) elution with acetonitrile and water
13
Work without Compromise
with the arium® pro Family
The arium® pro family has been developed to tailor to the requirements of the user. The simple
and intuitive glass interface enables each user to operate the system securely as well as
having fast access to all relevant data. Thanks to the different options for water dispensing,
working with the ultrapure water system is even more convenient.
15:32 23.06.09
0.055 µS/cm c
1.0 ppb TOC
Care menu
Display
The new display with innovative glass interface
features impressive operations. The intuitive menu
navigation makes working with the system simple
while the integrated output function can be
directly controlled. Features include:
– setting limit values for conductivity of feed
water and product water
– PIN-protected for basic settings (e.g., setting
limit values)
– colored warning and alarm messages that
indicate a required cartridge change, for
example, and which are also emphasized by
flashing graphic symbols
– constant control of the water and all important
parameters visible via the display (e.g., display
of system status, countdown for next cartridge
or filter change)
– direct and continuous output of details, such as
feed water and product water conductivity via
a printer or PC, as well as data storage on an
SD card
All illustrations refer to arium® pro systems with integrated TOC monitor.
14
Dispenser Unit
The new arium® pro allows users for
manual, volume or time controlled
water dispensing options via the
display.
Manual Output (Slider)
– continuous transition from
0.5 to 2 l/min
– graphic support
15:09 01.02.10
15:09 01.02.10
0.055 µS/cm c
0.055 µS/cm c
1.0 ppb TOC
1.0 ppb TOC
1.2 l
Stop
Volume Controlled Output
– 0.1 – 60 l
– 0.1 – 2 l (in 100 ml increments)
– 2 – 5 l (in 500 ml increments)
– 5 – 60 l (in 1000 ml increments)
– display of remaining dispensing
volume
– volume save function
Housing and System Setup
The compact design of the device enables you
to save space when positioning the system.
Its flat surface can accommodate containers
or even a second device. The high quality and
robust housing guarantees high practicality
in your laboratory environment. The design
of the units has:
– easy-to-open door provides faster access to
consumables (time-saving cartridge changes)
– separation of customer and service areas in
the system (no contact with electronics)
4.0 min
Stop
Time Controlled Output
– output from 30 sec to 59 min
– display of remaining time
– time save function
15
The arium® basic –
A Cost Effective Alternative
The arium® basic standard system fulfills the fundamental requirements of an ultrapure water system.
It produces ASTM type 1* water which can be used for both critical and routine applications.
The arium® basic is a cost effective alternative. Only the most vital functions are included for meeting
the requirements of ultrapure water production – streamlined without compromising quality.
* depending on feed water
16
Common Applications:
– atomic absorption (AA)
– ion chromatography
– inductively coupled plasma mass
spectrometry (ICP-MS)
– rinsing of glass containers
– preparation of buffers and media
– reagent manufacture
Pump
Design and Features of the
arium® basic System:
– innovative glass interface with touch
screen function
– time controlled dispensing
– manual, freely adjustable flow rates
up to 2 l/min
– conductivity measurement for product
water
– simple menu navigation with integrated
text support
– data storage via Ethernet or printer
– PIN-protected access to basic settings
and service
– service and alarm functions supported
by graphic displays
– intelligent alarm system
Pre-treatment
cartridge
Inlet
Pre-treatment
cartridge
Display
Outlet
Uniform Technology
The arium® basic system comes with all
of the important features for the production of ultrapure water, including
the same high quality cartridge sets as
with the arium® pro devices, and
achieves the same superior water
quality as the arium® pro DI.
17
arium® pro and basic –
Equipment and Specifications
Function | Equipment
Manual dispensing (adjustable via slider)
Volume controlled dispensing
Time controlled dispensing
Monitoring of inlet conductivity
Dispensed water display
Temperature monitoring
Ethernet (not yet available)
Data backup via (optional) printer
Data backup on SD card
Connection for remote dispenser
Sanitization port
Drainport
UV lamp
Ultrafilter
Options
TOC
Foot switch
Level sensors (2 pcs.)
Remote dispenser
Versions
Benchtop system
Wall-mounted system
Below-bench unit
18
basic
pro DI
pro UV
pro UF
pro VF
Product Water Quality
basic
pro DI
pro UV
pro UF
pro VF
Specific resistance (MO + cm):
18.2
18.2
18.2
18.2
18.2
Conductivity (μS/cm):
0.055
0.055
0.055
0.055
0.055
TOC content (ppb) @ 25 °C:
<5
<5
<2
<5
<2
Endotoxin content (EU/ml):
N/A
N/A
N/A
< 0.001
< 0.001
Particles (at 0.2 μm):
< 1/ml
< 1/ml
< 1/ml
< 1/ml
< 1/ml
Bacteria (CFU/1000 ml):
<1
<1
<1
<1
<1
Flow rate (l/min) :
up to 2
up to 2
up to 2
up to 1.7
up to 1.7
Empty weight:
17 kg
17 kg
18 kg
18 kg
18 kg
Operating weight:
27 kg
27 kg
28 kg
28 kg
28 kg
Operating weight with integrated TOC monitor:
N/A
N/A
29 kg
N/A
29 kg
1
2
Feed Water Requirements for arium® pro and basic
Specifications
Dimensions (W + H + D):
Interfaces:
Power supply:
35 + 49.2 + 45.1 cm
®
SD card (for arium pro
devices only)
RS-232
100–240 V AC (± 10%)
50–60 Hz, 80 W (max.)
130 VA (max.)
Minimum inlet pressure:
Maximum inlet pressure:
depressurized
6.9 bar
Specific conductance
RO water:
Distilled water:
Deionized water:
100 μS/cm
4 μS/cm
20 μS/cm
TOC:
Turbidity:
Silica:
< 50 ppb
< 1 NTU
< 1000 ppm
Values may vary depending on the quality of the feed water and the content
of impurities in the feed water, as well as the type of cartridge used.
2 At a pressure of 2 bar, without final filter
1
19
arium® EDI 61215 –
ASTM Type 2* Pure Water System
The Sartorius Stedim Biotech arium® EDI 61215 pure water system fulfills all requirements for modern
water purification systems. The arium® EDI 61215 consistently and reliably produces ASTM type 2*
water in accordance with the specific standards – for successful work in the laboratory.
* depending on feed water
20
Quick and Simple at a Glance
The display provides all information necessary for a
pure water system. Simple and clear menu navigation
makes it easy to work with the system. If the limit
values entered are exceeded, the service and alarm
functions signal the breach. All important parameters
can be accessed quickly and easily at the push of a
button.
– display of conductance for feed water
and product water
– rejection rate
– tank level
– temperature
Pure Water Quality for General Laboratory Applications
The arium® 61215 EDI system guarantees the removal of all
contamination in tap water. As well as pretreatment and
purification via the reverse osmosis module, the device also
performs softening and electronic | chemical deionization.
This procedure guarantees high water quality.
Common Areas of Application:
– preparation of microbiological media and buffers
– reagent manufacture
– pharmaceutical applications
– electrophoresis
– general biotechnological applications
– feed water for ultrapure water systems
– feed water for laboratory devices, such as autoclaves
and purification machines
21
arium® 61215 EDI
System Design
Pretreatment Cartridge
For Protection of the Reverse Osmosis Module
In the first stage, coarse contamination is removed
from the water to protect the reverse osmosis
membrane.
Conductivity|
Retention rate analysis
Solenoid
Pressure
valve
regulator
Inlet
Conductivity
cell
– activated carbon filter for the removal of chlorine
and organic substances
– 5 μm particle filter to prevent blockage of the
module and to extend service life
Pump
Solenoid
valve
Reverse Osmosis Module
For Effective Removal of Contamination
Reverse osmosis removes all contaminates to a certain
degree. The reverse osmosis module filters out 98–99%
of charged ions and 99% of all dissolved substances
as well as particles and microorganisms. The constant
flow rate also guarantees consistent crossflow of the
membrane, ensuring optimal water purification.
22
Pretreatment
cartridge
RO module
#1
RO module
#2
Softener
Reduces Calcium Carbonate
The softener cartridge removes remaining calcium
residues from the water, ensuring optimal water
quality for further processing via electronic |
chemical deionization.
– effective removal of calcium residues
– increases service life of the EDI module
Display
RO permeate
Concentration
chamber
Conductivity
cell
Conductivity
cell
Concentration
chamber
Concentration
chamber
Cathode
Wastewater
Softener
EDI Module
Ion Removal via Ionpure® EDI Technology
Electronic | chemical deionization removes remaining
ions from the water in the third purification stage.
Anode
– Continuous regeneration of the ion exchange resins
ensures constant quality and long service life
Product water
EDI
stack
RO pressure tank
Pressure Tank (30 l, 50 l, 70 l, and 100 l)
Secure Storage of Water
The completely sealed pressure tanks consist of an
FDA-approved, double-butyl membrane capable of
storing up to 100 l of pure water. Filling the tank
creates an internal pressure of up to 2.5 bar. This
removes the necessity for an additional pump for
distributing the product water to the point of use.
Drain
– reduction of contamination through microbes
and gases
– space-saving setup in desired locations
– transfer of product water with up to 2.5 bar
to the point of use
23
Functionality of
EDI Technology
The core of the arium® 61215 EDI system is an
EDI module with Ionpure® technology. RO water
is fed through the module at right angles to an
applied voltage and, thus water gets deionized.
The EDI technology is based upon the principle that
ions move towards the electrodes in an electrical field.
The ions are only allowed to pass through in one direction. The negatively charged anions move towards
the anode and the positively charged cations towards
the cathode. On their way, the ions pass through
ion-selective membranes, the anions through an
anion-selective membrane and the cations through
a cation-selective membrane. This creates areas with
increased ion concentration, known as concentration
chambers, and areas with reduced ion concentration,
or cleaning chambers.
So that this process can proceed without turbulence
and back-mixing, the areas are filled with ion exchange resin. The ions are bound to the ion exchange
resin and move on its surface to the concentrate areas.
Through the dissociation of the water into OH- and
H+ ions, this resin continues to regenerate and is
capable of further ion exchange. No chemicals are
required for regeneration.
The concentrate areas are sprayed with a low volume
flow to transport the ions away. Thus, the inflow is
split into a low salt "diluate flow" and a concentration
flow (waste water).
24
RO permeate
Concentration
chamber
Concentration
chamber
Concentration
chamber
Cathode
Wastewater
Anode
Product water
arium® 61215 EDI –
Specifications
Water Quality Achieved
Conductivity (μS/cm)*:
0.2–0.07
Resistance (MΩ + cm)*:
5–15
TOC*:
< 30 ppb
Bacteria**:
< 1 CFU/1000 ml
Particles**:
< 1/ml
Specifications
Feed Water Requirements
Flow rate capacity (± 20% at 25°C)*:
15 l/hr
Minimum inlet pressure:
1.2 bar
Dimensions (W + H + D):
43 + 48 + 33.4 cm
Maximum inlet pressure:
6.9 bar
Empty weight:
20 kg
Maximum conductance***:
< 1000 μS/cm
Operating weight:
25 kg
Temperature:
5–35°C
Power supply:
100–240 V AC,
50–60 Hz,
single-phase
Max. total hardness (max. CaCO3):
360 ppm
Fouling index (SDI):
<5
Free chlorine:
0.1 ppm
Turbidity:
< 1 NTU
Iron (evaluated as total Fe content):
< 0.1 ppm
* Values may vary depending on the temperature and quality of the feed water
and | or amount of impurities contained in the feed water.
** When using a Sartopore® 2 150 final filter
*** In the absence of CO2
25
arium® 61316
Reverse Osmosis System
The Sartorius Stedim Biotech arium® 61316 reverse osmosis system is the modern solution
for reliable production of up to 16 l/hr ASTM type 3* water.
Pure Water Quality for General
Laboratory Applications
The arium® 61316 reverse osmosis
system is guaranteed to produce
pure water for general laboratory
applications thanks to a 99%
rejection rate of ions, organic
components, bacteria, and viruses.
Common Areas of Application:
– feed water for glassware machines,
autoclaves, and air humidifiers
– feed water for ultrapure water
systems
– rinsing of glass and laboratory
containers
– general laboratory applications
* depending on feed water
26
Cost Effective Use of Technology
The coarse contamination initially contained in the
tap water is removed by the pretreatment cartridge
to protect the delicate reverse osmosis module.
The high performance membranes reliably produce
good water quality and reduce water consumption.
The modules are optimally protected from deposits
via automatic membrane backflushing with
permeate.
Simple Data Access
This device provides all information necessary for a pure
water system. As with the EDI system, the arium® 61316
reverse osmosis system comes with professional menu
navigation, enabling work to be structured in a
convenient and user-friendly manner. The clear system
information and text supported service functions make
the device easy to understand and facilitates intuitive
operation for the user.
– display of conductance for feed water
and product water
– rejection rate as a %
– tank fill level indicator
– temperature in °C or °F
27
The arium® 61316
Reverse Osmosis System Step by Step
Pretreatment Cartridge
For Protection of the Reverse Osmosis Module
In the first stage, coarse contamination is removed
from the water to protect the reverse osmosis
membrane.
Pressure
regulator
Inlet
Conductivity
cell
– activated carbon filter for the removal of chlorine
and organic substances
– 5 μm particle filter to prevent blockage of the
module and to extend service life
Pump
Solenoid
valve
Reverse Osmosis Module
For Effective Removal of Contamination
Reverse osmosis removes all contamination to a
certain degree. The reverse osmosis module filters out
98–99% of charged ions and 99% of all dissolved
substances as well as particles and microorganisms.
The constant flow rate also guarantees consistent
crossflow of the membrane, ensuring optimal water
purification.
28
Pretreatment
cartridge
RO module
#1
Conductivity|
Retention rate analysis
Display
The RO membranes are also rinsed with RO permeate
to increase the service life of the module.
Conductivity
cell
RO pressure tank
RO module
#2
Drain
Conductivity Measurement
For Controlling the Rejection Rate
The integrated conductivity measuring cells measure
feed water and product water to display the resulting
rejection rate.
Pressure Tank (30 l, 50 l, 70 l, and 100 l)
Secure Storage of Water
The completely sealed pressure tanks consist of an
FDA-approved, double-butyl membrane capable of
storing up to 100 l of pure water. Filling the tank
creates an internal pressure of up to 2.5 bar. This
removes the necessity for an additional pump for
distributing the product water to the point of use.
– reduction of contamination through microbes
and gases
– space-saving setup in desired locations
– transfer of product water with up to 2.5 bar
to the point of use
29
arium® 61316 –
Specifications
30
Water Quality Achieved
Rejection Rates
Conductivity (μS/cm)*:
< 20
Monovalent ions:
up to 98%
Resistance (MΩ + cm)*:
> 0.05
Polyvalent ions:
up to 99%
Bacteria**:
< 1 CFU/1000 ml
Particles:
> 99%
Particles**:
< 1/ml
Microorganisms:
> 99%
Dissolved organic
substances (MW > 300):
> 99%
Specifications
Feed Water Requirements
Flow rate capacity (± 20% at 25°C)*:
16 l/hr
Minimum inlet pressure:
1.2 bar
Dimensions (W + H + D):
43 + 48 + 33.4 cm
Maximum inlet pressure:
6.9 bar
Empty weight:
14 kg
Maximum conductance:
< 1500 μS/cm
Operating weight:
20 kg
Temperature:
5–35°C
Power supply:
100–240 V AC,
50–60 Hz,
single-phase
Max. total hardness (max. CaCO3):
360 ppm
Fouling index (SDI):
<5
Free chlorine:
0.1 ppm
Turbidity:
< 1 NTU
Iron (evaluated as total Fe content):
< 0.1 ppm
* Values may vary depending on the temperature and quality of the feed water and/or amount of impurities contained in the feed water.
** When using a Sartopore® 2 150 final filter
31
arium® 613L
Reverse Osmosis System
The Sartorius Stedim Biotech arium® 613L reverse osmosis system reliably produces ASTM type 3* water
and is ideally suited for applications with high water consumption. The complete supply to buildings or
individual floors is ensured centrally from roof or basement level.
* depending on feed water
32
The arium® 613L reverse osmosis system can produce up to 300 l/hr and features an
integrated 100 l tank as well as a transport pump capable of supplying different
laboratories or several floors. Where larger water volumes are required, the optional
tank systems (200 l, 600 l, or 1,000 l) offer a convenient solution. Different output
points such as ultrapure water systems, laboratory devices, or direct output options can
be connected effortlessly.
– integrated pressure booster pump guarantees constant pressure and flow rate
– permeate transport pump distributes the product water with up to 2 m3/h at 3.7 bar
to the point of use
Central Water System for Large
Volumes of Pure Water
The arium® 613L reverse osmosis system
guarantees the removal of all contamination contained in tap water via the
5 μm particle filter to additionally protect the RO module. The systems have
been specially developed for applications
with a high daily requirement of RO
water. In order to meet future increases
in water consumption, the arium® 613L
can be upgraded cost-effectively in
increments of 50 liters per hour up to
a total capacity of 300 l/hr.
Common Areas of Application:
– feed water for glassware machines,
autoclaves, and air humidifiers
– feed water for ultrapure water systems
– general laboratory applications
A
B
C
D
= Research and
development
= Scullery
= HPLC laboratory
= Cell culture
laboratory
1
2
3
4
5
6
7
8
9
10
= arium® pro DI
= Glassware machines I and II
= Autoclaves I and II
= Direct dispensing (faucet)
= arium® pro UV
= arium® pro UF
= arium® pro VF
= Autoclave
= arium® pro VF
= arium® pro VF
33
arium® 613L Reverse Osmosis System
Specifications
34
Water Quality Achieved
Rejection Rates
Conductivity: < 20 μS/cm*
Monovalent ions:
up to 98%
Resistance:
Polyvalent ions:
up to 99%
Particles:
> 99%
Microorganisms:
> 99%
Dissolved organic
substances (MW > 300):
> 99%
> 0.05 MΩ + cm*
Specifications
Flow rate
capacity
(± 20% at 25°C)*:
50, 100, 150,
200, 250,
300 l/hr
Max. recovery
rate*:
approx. 40–80%
Dimensions
(W + H + D):
58 + 81 + 58 cm
Systems
613L050
613L100
613L150
613L200
613L250
613L300
Capacity [l/h]**
50
100
150
200
250
300
Tank [l]
100
100
100
100
100
100
Electrical connection [V]
230
230
230
230
230
230
Power consumption [kW/h]
1.3
1.3
1.3
1.3
1.3
1.3
Power frequency [Hz]
50
50
50
50
50
50
Max. water temperature
25°C
25°C
25°C
25°C
25°C
25°C
Max. inlet pressure
7 bar
7 bar
7 bar
7 bar
7 bar
7 bar
Min. inlet pressure
2 bar
2 bar
2 bar
2 bar
2 bar
2 bar
Weight (full)
150 kg
151 kg
152 kg
153 kg
154 kg
155 kg
Bacteria (CFU/1000 ml)
<1
<1
<1
<1
Number of membranes
1
2
3
4
5
6
* Depending on feed water quality and temperature
** Potable water quality at 10°C, 3 bar, max. 500 mg/l total salt content ± 5% flow rate
35
Intelligent Design:
Flexibility in the Laboratory
In terms of flexibility, the new arium® pro and basic series as well as the arium® 61215 EDI
and arium® 61316 RO system leaves nothing to be desired. Individually adaptable to the
laboratory conditions, the height adjustable displays allow space saving installation of
the systems as benchtop, under-the-bench, or even wall-mounted systems.
Benchtop Unit
arium® benchtop units with head-side integrated display unit are an ideal, space saving solution for standard installation in the laboratory. The top-mounted
head assembly enables optimal visibility of the display
as well as an ideal position for operating the menu.
arium® pro | basic systems are also equipped with
integrated stowage space on the top of the system.
The horizontal surface therefore provides additional
space for accommodating sample containers or
sampling chambers, for example.
Below-bench Unit
Space is a vital commodity in the laboratory. To
ensure the highest degree of flexibility with limited
space conditions, the systems can also be integrated
into the laboratory furniture. The display and
dispensing unit can be located up to 2.8 m from
the device while still remaining convenient to use.
36
Wall mounted System
A further space saving solution is the wall mounted version of
the arium® devices. The supplied wall bracket enables the device
to be easily positioned above the relevant work area. Thanks to
the flexible installation options of the display with the dispensing
unit, the operating comfort is maintained without restrictions.
Remote Dispenser Accessory
The arium® remote dispenser is the solution for greater flexibility
in the laboratory. The arium® remote dispenser is an ergonomic,
easy-to-handle dispensing unit which, thanks to its different
designs, can be used for dispensing both pure and ultrapure water.
The variants are available as benchtop units with stand foot or
as a wall mounted system depending on space requirements.
Thanks to the extended tube guide, the work area for dispensing
is extended to up to three meters. Furthermore, the height adjustable stand foot enables optimal adjustment to different sizes of
sampling chamber. The stand foot is also optionally available for
the display | dispensing unit.
Water Monitor Accessory
The arium® water monitor provides additional security
by identifying water leaks early and guaranteeing optimal
protection in the laboratory.
37
Environmentally Friendly Use
and Quality Assurance
Environmentally Friendly Technology
Eco Mode
The arium® models have an automatic eco mode, whose
start time can be set individually. The device goes into
a standby mode to facilitate energy efficiency when
not in use.
Cartridges
Thanks to the high performance cartridges inserted
into the device combined with state-of-the-art technology, such as electronic|chemical deionization, the
service life of the filters is increased considerably,
which reduces environmental impact.
Quality Assurance and Certification
Our devices are subjected to constant quality controls during
manufacture. The produced water quality is also rigorously
tested with regard to observing international standards and
regulations. This includes ensuring that the water complies
with the following requirements:
– ASTM, American Society for Testing and Materials
– ISO 3696, International Organization for Standardization;
Water for analytical laboratory use
– Pharmacopeia, specified materials, including water for
medical applications
Overview of Regulations and Standards
Regulation | arium® arium®
Standard
pro DI| pro UF
basic
ASTM type I
+
+
ASTM type II
+
+
ISO 3696 type I
+
+
ISO 3696 type II
+
+
NCCLS
+
+
CAP
+
+
Aqua purificata EU
+****
+****
Aqua purificata USP
+****
+****
Highly purified water EU* –
+
WFI EU**
–
–
WFI USP***
–
+****
arium® arium® 61316 61512
pro UV pro VF RO
EDI
+
+
+
+
+
+
+****
+****
–
–
–
+*: depends on feed water quality
WFI EU**: validation necessary, distillation necessary
WFI USP***: validation necessary
+****: validation necessary
38
+
+
+
+
+
+
+****
+****
+
–
+****
–
–
–
+*
+*
+*
+****
–
–
–
–
–
+
–
+
–
–
+****
+****
–
–
–
Technical Service and Support
Our application and service specialists undergo special training and understand our customers'
applications, keeping in mind all legal requirements for the industry. Our employees have impressive
experience in diverse sectors of the pharmaceutical | biotech, chemical, and food and drink industries
in which the highest grade water is indispensable. First class service in installation, validation, and
maintenance, as well as individual consultation are
a standard for us.
Take Advantage of the Range of Offers from
Our Service Department
– Needs analysis
– Installation and startup
– Technical support
– Equipment qualification (IQ, OQ) and
validation
– Preventive maintenance service and service
agreements
– Corrective maintenance and spare part service
– Customer specific user training
For further information, visit
www.sartorius-stedim.com/instrument-services
39
Ordering Information
Order Number
arium® pro
Ultrapure
arium® H20 pro
Water Systems without TOC
Monitor
40
Order Number
arium® H20 pro
with Integrated
TOC Monitor
Description
H2Opro-DI-B
–
arium® pro DI wall-mounted system for producing ultrapure water for standard
applications with front bottom-mounted display | dispenser unit and integrated
wall bracket for the system
H2Opro-DI-T
–
arium® pro DI benchtop system for producing ultrapure water for standard
applications with front top-mounted display | dispenser unit
H2Opro-DI-D
–
arium® pro DI built-in system for producing ultrapure water for standard
applications, including wall-mounting kit for the display | dispenser unit that can
be installed up to 2.8 meters from the system
H2Opro-UF-B
–
arium® pro UF wall-mounted system for producing ultrapure water for cell culture
applications with front bottom-mounted display | dispenser unit and integrated
wall bracket for the system
H2Opro-UF-T
–
arium® pro UF benchtop system for producing ultrapure water for cell culture
applications with front top-mounted display | dispenser unit
H2Opro-UF-D
–
arium® pro UF built-in system for producing ultrapure water for cell culture
applications, including wall-mounting kit for the display | dispenser unit that can
be installed up to 2.8 meters from the system
H2Opro-UV-B
H2Opro-UV-B-TOC
arium® pro UV wall-mounted system for producing ultrapure water for chromato–
graphy applications with front bottom-mounted display | dispenser unit and
integrated wall bracket for the system
H2Opro-UV-T
H2Opro-UV-T-TOC
arium® pro UV benchtop system for producing ultrapure water for chromato–
graphy applications with front top-mounted display | dispenser unit
H2Opro-UV-D
H2Opro-UV-D-TOC
arium® pro UV built-in system for producing ultrapure water for cell chromato–
graphy applications, including wall-mounting kit for the display | dispenser unit
that can be installed up to 2.8 meters from the system
H2Opro-VF-B
H2Opro-VF-B-TOC
arium® pro VF wall-mounted system for producing ultrapure water for standard,
cell culture, and chromatography applications with front bottom-mounted
display | dispenser unit and integrated wall bracket for the system
H2Opro-VF-T
H2Opro-VF-T-TOC
arium® pro VF benchtop system for producing ultrapure water for standard,
cell culture, and chromatography applications with front top-mounted
display | dispenser unit
H2Opro-VF-D
H2Opro-VF-D-TOC
arium® pro UV built-in system for producing ultrapure water for standard, cell
culture, and chromatography applications, including wall-mounting kit for the
display | dispenser unit that can be installed up to 2.8 meters from the system
arium® basic
Ultrapure
Water System
Cartridge sets
for arium® pro,
arium® basic
and arium®
611 systems
Order Number
Description
H20 basic-B
arium® basic wall-mounted system for producing ultrapure water for standard applications with front
bottom-mounted display | dispenser unit and integrated wall bracket for the system
H20 basic-T
arium® basic benchtop system for producing ultrapure water for standard applications with front
top-mounted display | dispenser unit
Order Number
Product Name
Description
H2O-A-PACK
Analytical Kit
Cartridge set for arium® VF or UV ultrapure water systems
H2O-B-PACK
Biological Kit
Cartridge set for arium® UF ultrapure water systems
H2O-E-PACK
Elemental Kit
Cartridge set for arium® basic and DI ultrapure water systems
H2O-U-PACK
Universal Kit *
Cartridge set for arium® ultrapure water systems with tap water feed
* Tap water cartridges should be used only after the feed water specifications have been checked and following consultation
with the responsible Sartorius application specialist.
41
arium® pro
Consumables
Order Number
Description
611CDU5
Ultrafilter
611CEL1
UV lamp
611CDS2
Sanitization kit (with 2 syringes)
611CDS6
Sanitization kit (with 6 syringes)
5441307H4--CE--B Sartopore® 2 150 sterile final filters, pore size: 0.2 μm (5 pcs.)
arium® pro
Accessories
42
Order Number
Description
H2Opro-AMDG1
Remote dispenser including height-adjustable stand foot
H2Opro-AMDG2
Remote dispenser including wall mounting kit
H2Opro-ADM1
Display mounting kit including height-adjustable stand foot
611APR1
Dot matrix printer for data logging
610AWGI
Water monitor
H2O-AFS1
Foot switch for water dispensing
H2O-ALS1
Two level sensors for connection to an open tank system
arium® 61215
Systems
arium® 61215
Consumables
arium® 61215
Accessories
Order Number
arium® 61215
Benchtop Unit
Order Number
arium® 61215
Built-in Unit
Description
61215030F05M1A
61215030F05M1D
Complete arium® EDI 61215 ASTM type 2 water system with 30-liter storage
tank* (equipment supplied: arium® EDI 61215, water storage tank, 2+ reverse
osmosis modules, 4+ softener cartridges, 2 pre-treatment cartridges +
disinfection syringes for the reverse osmosis modules and water storage tank).
61215050F05M1A
61215050F05M1D
Complete arium® EDI 61215 ASTM type 2 water system with 50-liter storage
tank* (equipment supplied: arium® EDI 61215, water storage tank, 2+ reverse
osmosis modules, 4+ softener cartridges, 2 pre-treatment cartridges +
disinfection syringes for the reverse osmosis modules and water storage tank).
61215070F05M1A
61215070F05M1D
Complete arium® EDI 61215 ASTM type 2 water system with 70-liter storage
tank* (equipment supplied: arium® EDI 61215, water storage tank, 2+ reverse
osmosis modules, 4+ softener cartridges, 2 pre-treatment cartridges +
disinfection syringes for the reverse osmosis modules and water storage tank).
61215100F05M1A
61215100F05M1D
Complete arium® EDI 61215 ASTM type 2 water system with 100-liter storage
tank* (equipment supplied: arium® EDI 61215, water storage tank, 2+ reverse
osmosis modules, 4+ softener cartridges, 2 pre-treatment cartridges +
disinfection syringes for the reverse osmosis modules and water storage tank).
Order Number
Description
613CPF05-------V
2+ pre-treatment cartridges
612CPS1--------A
4+ softener cartridges
613CPM4-------V
2+ RO modules
611CDS2
Disinfection set for the tank (2 syringes)
612CDS2
Disinfection set for the RO modules (2 syringes)
Order Number
Description
613-AMDG1
Remote dispenser for 613APV pressure tank, including height-adjustable stand foot
613-AMDG2
Remote dispenser for 613APV pressure tank, including wall-mounting kit
613APV31
30-liter tank*
613APV50
50-liter tank*
613APV70
70-liter tank*
613APV100
100-liter tank*
* With tank pressure of 2.5 bar
43
arium® 61316 Order Number
Reverse Osmo- arium® 61316
Benchtop Unit
sis System
arium® 61316
Consumables
arium® 61316
Accessories
44
Order Number
arium® 61316
Built-in Unit
Description
61316030F05M1A
61316030F05M1D
Complete reverse osmosis system with a 30-liter storage tank* (equipment
included: arium® 61316, water storage tank, 2+ reverse osmosis modules,
2 pre-treatment cartridges + disinfection syringes for the reverse osmosis
modules and water storage tank).
61316050F05M1A
61316050F05M1D
Complete reverse osmosis system with a 50-liter storage tank* (equipment
included: arium® 61316, water storage tank, 2+ reverse osmosis modules,
2 pre-treatment cartridges + disinfection syringes for the reverse osmosis
modules and water storage tank).
61316070F05M1A
61316070F05M1D
Complete reverse osmosis system with a 70-liter storage tank* (equipment
included: arium® 61316, water storage tank, 2+ reverse osmosis modules,
2 pre-treatment cartridges + disinfection syringes for the reverse osmosis
modules and water storage tank).
61316100F05M1A
61316100F05M1D
Complete reverse osmosis system with a 100-liter storage tank* (equipment
included: arium® 61316, water storage tank, 2+ reverse osmosis modules,
2 pre-treatment cartridges + disinfection syringes for the reverse osmosis
modules and water storage tank).
Order Number
Description
613CPF05-------V
2+ pre-treatment cartridges
613CPM4-------V
2+ RO modules
611CDS2
Disinfection set for the tank (2 syringes)
612CDS2
Disinfection set for the RO modules (2 syringes)
Order Number
Description
613-AMDG1
Remote dispenser for 613APV pressure tank, including height-adjustable stand foot
613-AMDG2
Remote dispenser for 613APV pressure tank, including wall-mounting kit
613APV31
30-liter tank*
613APV50
50-liter tank*
613APV70
70-liter tank*
613APV100
100-liter tank*
* With tank pressure of 2.5 bar
arium® 613L
Reverse Osmosis System
arium® 613L
Consumables
Order Number
Description
613L050
Complete arium® RO system with distribution pump, 50 l/h, 230 Volt, 50 Hz, including 5 μm prefilter,
RO membrane and 100-l tank
613L050D
Complete arium® RO system without distribution pump (in conjunction with an external tank system)
50 l/h, 230 Volt, 50 Hz, including 5 μm prefilter, RO membrane
613L100
Complete arium® RO system with distribution pump, 100 l/h, 230 Volt, 50 Hz, including 5 μm prefilter,
2+ RO membranes and 100-l tank
613L100D
Complete arium® RO system without distribution pump (in conjunction with an external tank system)
100 l/h, 230 Volt, 50 Hz, including 5 μm prefilter and 2+ RO membranes
613L150
Complete arium® RO system with distribution pump, 150 l/h, 230 Volt, 50 Hz, including 5 μm prefilter,
3+ RO membranes and 100-l tank
613L150D
Complete arium® RO system without distribution pump (in conjunction with an external tank system)
150 l/h, 230 Volt, 50 Hz, including 5 μm prefilter and 3+ RO membranes
613L200
Complete arium® RO system with distribution pump, 200 l/h, 230 Volt, 50 Hz, including 5 μm prefilter,
4+ RO membranes and 100-l tank
613L200D
Complete arium® RO system without distribution pump (in conjunction with an external tank system)
200 l/h, 230 Volt, 50 Hz, including 5 μm prefilter and 4+ RO membranes
613L250
Complete arium® RO system with distribution pump, 250 l/h, 230 Volt, 50 Hz, including 5 μm prefilter,
5+ RO membranes and 100-l tank
613L250D
Complete arium® RO system without distribution pump (in conjunction with an external tank system)
250 l/h, 230 Volt, 50 Hz, including 5 μm prefilter and 5+ RO membranes
613L300
Complete arium® RO system with distribution pump, 300 l/h, 230 Volt, 50 Hz, including 5 μm prefilter,
6+ RO membranes and 100-l tank
613L300D
Complete arium® RO system without distribution pump (in conjunction with an external tank system)
300 l/h, 230 Volt, 50 Hz, including 5 μm prefilter and 6+ RO membranes
Order Number
Description
613L-AE002
Conductivity meter
613L-AE002
UV lamp with housing
613L-CH001
5 µm prefilter
613L-CH002
RO membrane
45
arium® 613L
Accessories
Order Number
Description
613AOV200
Standard 200-l tank with system-controlled distribution pump (for RO 613L050D, 613L100D,
613L150D, 613L200D, 613L250D, & 613L300D systems)
613AOV600
Standard 600-l tank with system-controlled distribution pump (for RO 613L050D, 613L100D,
613L150D, 613L200D, 613L250D, & 613L300D systems)
613AOV1000
Standard 1000-l tank with system-controlled distribution pump (for RO 613L050D, 613L100D,
613L150D, 613L200D, 613L250D, & 613L300D systems)
arium® 615S
Order Number
Water Soften- 615S004
ing System
arium® 615S
Consumables
46
Description
arium® 615S water softening system for up to 400 l, time-controlled regeneration and 25 kg salt,
ready-to-use
615S006
arium® 615S water softening system for up to 600 l, time-controlled regeneration and 25 kg salt,
ready-to-use
615S012
arium® 615S water softening system for up to 1200 l, time-controlled regeneration and 25 kg salt,
ready-to-use
Order Number
Description
615SC001
25 kg salt tablets for regeneration
arium® 615DI
Complete
Deionization
Cartridges
Order Number
Description
615DI004
arium® complete deionization cartridge including hose connection set, capacity up to 420 l at 20° dH
615DI007
arium® complete deionization cartridge including hose connection set, capacity up to 650 l at 20° dH
615DI010
arium® complete deionization cartridge including hose connection set, capacity up to 1050 l at 20° dH
615DI014
arium® complete deionization cartridge including hose connection set, capacity up to 1400 l at 20° dH
arium® 615DI
Consumables
Order Number
Description
615DIC01
arium® refill pack for complete deionization cartridges, ion exchange resin mix
in 25 l PE bag
arium® 615DI
Accessories
Order Number
Description
615ALC1
arium® conductivity analyzer for complete deionization cartridges with LED display
(red > 20 µS/cm & green < 20 µS/cm)
615ADC1
arium® conductivity analyzer for complete deionization cartridges with digital measurement value
display, conductivity measurement range 0.056–200 µS/cm
47
Application | System Overview
arium®
61215 EDI
arium®
61316
arium®
613L
Feed water for glassware machines, autoclaves,
air humidifiers
++
+++
+++
Feed water for ultrapure water systems
+
+++
+++
+++
+++
++
++
Application
arium®
pro DI | basic
arium®
pro UF
arium®
pro UV
arium®
pro VF
General laboratory applications
Rinsing of glass and laboratory containers
++
Steam generation
+++
Preparation microbiological media and buffers
+++
Reagent manufacture
+++
+++
+++
+++
General media preparation
++
++
++
++
++
Biological applications
Microbiology
++
+++
Molecular biology
+++
Biotechnological applications:
cell biology, biochemistry, genetics, DNA/RNA applications,
medical diagnostics, tissue production, biomolecular
procedures, biotech, and life sciences
++
+++
DNA sequence analysis
+++
+++
IVF (in vitro fertilization)
+++
+++
Cell culture media
+++
+++
Protein | Enzyme manufacture
+
++
Biochemical applications, general
+++
+
++
Biochemical applications, PCR
Drug discovery
48
+++
++
+++
++
++
++
++
++
arium®
pro DI | basic
arium®
pro UF
arium®
pro UV
arium®
pro VF
Inorganic analytical methods:
IC, AAS, ICP, ICP-MS
+++
++
+++
++
Electrochemistry
+++
++
+++
+
Chromatography
+
+
+++
+++
HPLC
++
++
+++
+++
+++
+++
+++
Application
arium®
61215 EDI
arium®
61316
arium®
613L
Analytical applications
HPLC with low TOC content
Analysis of trace elements (HPLC, IC, TOC)
++
++
+++
Photometric methods:
filter photometer, UV, UV-VIS
Chromatography detectors
++
+++
+++
Mass spectrometry
+
+
+++
Electrophoresis
Film and gel technology
+
+
+++
Electrophoresis
+
+
++
+++
Nanotechnology
++
++
++
++
The table shows recommendations for various applications and can be used as a guideline. For help finding a device that
meets your special requirements, please contact us directly.
+ = suitable to a limited extent
++ = suitable
+++ = optimal
49
Sales and Service Contacts
For further contacts, visit www.sartorius-stedim.com
America
Asia | Pacific
Germany
Sartorius Stedim Biotech GmbH
August-Spindler-Strasse 11
37079 Goettingen
Denmark
Sartorius Stedim Nordic A/S
Hoerskaetten 6D, 1.
DK-2630 Taastrup
USA
Sartorius Stedim North America Inc.
5 Orville Drive
Bohemia, NY 11716
Australia
Sartorius Stedim Australia Pty. Ltd.
Unit 5, 7-11 Rodeo Drive
Dandenong South Vic 3175
Phone +49.551.308.0
Fax +49.551.308.3289
Phone +45.7023.4400
Fax +45.4630.4030
Toll-Free +1.800.368.7178
Fax +1.631.254.4253
Phone +61.3.8762.1800
Fax +61.3.8762.1828
Hungary
Sartorius Stedim Hungária Kft
Kagyló u. 5
2092 Budakeszi
Sartorius Stedim SUS Inc.
1910 Mark Court
Concord, CA 94520
China
Sartorius Stedim Beijing
Representative Office
No. 33, Yu’an Road,
Airport Industrial Zone B, Shunyi District
Beijing 101300
www.sartorius-stedim.com
Sartorius Stedim Systems GmbH
Schwarzenberger Weg 73–79
34212 Melsungen
Phone +49.5661.71.3400
Fax +49.5661.71.3702
www.sartorius-stedim.com
France
Sartorius Stedim Biotech S.A.
ZI Les Paluds
Avenue de Jouques – BP 1051
13781 Aubagne Cedex
Phone +33.442.845600
Fax +33.442.845619
Sartorius Stedim France SAS
ZI Les Paluds
Avenue de Jouques – CS 71058
13781 Aubagne Cedex
Phone +33.442.845600
Fax +33.442.846545
Austria
Sartorius Stedim Austria GmbH
Franzosengraben 12
A-1030 Vienna
Phone +43.1.7965763.18
Fax +43.1.796576344
Belgium
Sartorius Stedim Belgium N.V.
Leuvensesteenweg, 248/B
1800 Vilvoorde
Phone +32.2.756.06.80
Fax +32.2.756.06.81
Phone +36.23.457.227
Fax +36.23.457.147
Phone +1.925.689.6650
Toll Free +1.800.914.6644
Fax +1.925.689.6988
Italy
Sartorius Stedim Italy S.p.A.
Via dell’Antella, 76/A
50012 Antella-Bagno a Ripoli (FI)
Sartorius Stedim Systems Inc.
201 South Ingram Mill Road
Springfield, MO 65802
Phone +39.055.63.40.41
Fax +39.055.63.40.526
Phone +1.417.873.9636
Fax +1.417.873.9275
Phone +86.10.80426516
Fax +86.10.80426580
Sartorius Stedim Shanghai
Represantative Office
Room 618, Tower 1, German Centre,
Shanghai, PRC., 201203
Phone +86.21.28986393
Fax +86.21.28986392.11
Netherlands
Sartorius Stedim Netherlands B.V.
Edisonbaan 24
3439 MN Nieuwegein
Argentina
Sartorius Argentina S.A.
Int. A. Avalos 4251
B1605ECS Munro
Buenos Aires
Phone +31.30.6025080
Fax +31.30.6025099
Phone +54.11.4721.0505
Fax +54.11.4762.2333
Poland
Sartorius Stedim Poland Sp. z o.o.
ul. Wrzesinska 70
62-025 Kostrzyn
Brazil
Sartorius do Brasil Ltda
Av. Dom Pedro I, 241
Bairro Vila Pires
Santo André
São Paulo
Cep 09110-001
India
Sartorius Stedim India Pvt. Ltd.
#69/2-69/3, Jakkasandra
Kunigal Road, Nelamangala Tq
Bangalore – 562 123
Phone +55.11.4451.6226
Fax +55.11.4451.4369
Phone +91.80.4350.5361
Fax +91.80.4350.5253
Mexico
Sartorius de México S.A. de C.V.
Circuito Circunvalación Poniente No. 149
Ciudad Satélite
53100 Naucalpan, Estado de México
Japan
Sartorius Stedim Japan K.K.
KY Building, 8–11
Kita Shinagawa 1-chome
Shinagawa-ku
Tokyo 140-0001
Phone +48.61.647.38.40
Fax +48.61.879.25.04
Spain
Sartorius Stedim Spain SA
C/Isabel Colbrand 10,
Oficina 70
Polígono Industrial de Fuencarral
28050 Madrid
Phone +34.90.2110935
Fax +34.91.3589623
Switzerland
Sartorius Stedim Switzerland AG
Ringstr. 24 a
8317 Tagelswangen
Phone +41.52.354.36.36
Fax +41.52.354.36.46
U.K.
Sartorius Stedim UK Limited
Longmead Business Park
Blenheim Road, Epsom
Surrey KT19 9 QQ
Phone +44.1372.737159
Fax +44.1372.726171
Phone +52.5555.62.1102
Fax +52.5555.62.2942
Sartorius Stedim Guangzhou Office
Room 704, Broadway Plaza,
No. 233–234 Dong Feng West Road
Guangzhou 510180
Phone +86.20.8351.7921
Fax +86.20.8351.7931
Phone +81.3.3740.5407
Fax +81.3.3740.5406
Malaysia
Sartorius Stedim Malaysia Sdn. Bhd.
Lot L3-E-3B, Enterprise 4
Technology Park Malaysia
Bukit Jalil
57000 Kuala Lumpur
Phone +60.3.8996.0622
Fax +60.3.8996.0755
Singapore
Sartorius Stedim Singapore Pte. Ltd.
1 Science Park Road,
The Capricorn, #05-08A,
Singapore Science Park 2
Singapore 117528
Phone +65.6872.3966
Fax +65.6778.2494
Specifications subject to change without notice. Printed in Germany on paper that has been bleached without any use of chlorine. | W
Publication No.: XX-0000-e07051 · Order No.: 00000-000-00 · Ver. MM | YYYY
Europe
Type 1 Water
Ma
chr nufa
c
pho omat ture
tom ogr of r
etr aphy eage
ic m , H nt
eth PLC s, ele
ods , an ctr
, m aly och
ass sis o em
spe f tr istr
ctr ace y,
om
etr elem
y
ent
s,
Preparation of buffers and media,
manufacture of reagents, rinsing of glass
vessels, inorganic analytical methods:
IC, AAS, ICP, ICP-MS, electrochemistry
Manufacture of reagents, molecular biology,
RNA | DNA purification, DNA sequence analysis,
IVF, cell culture media, PCR, chromatography,
HPLC, analysis of trace elements, electrophoresis
arium pro VF
®
I
ED
15
2
61
–
–
615DI cartridges
–
r
ne
fte
o
S 5S al at
61 ption H)
(o 0° d
>2
I
D
615
16 or
615S RO 613 DI
Softener l
5
1
612 E
(optiona dH)
°
0
2
at >
16 )
613atory
O
R lig
(ob
UV
pro
m®
RO
E DI
DI
r
ate
W
p
I ca
rtri
dge
Soft
s
(opt ener 6
i
1
at > onal 5S
20°
RO 6
dH)
6121 1316 o
5 ED r
I
–
615
D
–
Ty p
e
T
–
ate
r
e
yp
ari
u
DI
Tap
W
2
arium® pro DI
arium® basic
r
Tap Wate
RO
EDI
R
ED O
I
Ta
Type 3
Reverse osmosis systems
61316 (16 l/h)
613L (50–300 l/h)
RO
Type 3
r
ate
pW
r
Tap Wate
RO
DI
3W
a
t er
61215 EDI
system (15 l/h)
So
61 ftene
(op 5S r
>26 tiona
° dH l at
)
6
Type 2
Ta
r
6o
31 DI
1
6 E
trid
RO 215
car
1
S
I
6
15
5D
61
r6
e
n l )
fte na H
So ptio 0° d
(o t >2
a
s
ge
p
W
ate
r
ter
Wa
UF
31
–
arium® pro
(1.7–2 l/min)
um
ari
pro
61
–
Type 1
®
L
or
615S RO 61316 I
Softener l
D
E
5
1
612
(optiona dH)
at >20°
613
615DI cartridges
–
DI
–
Ta
RO
EDI
Your System
–
S
6 oft
(o 15S ener
> pt
2
0° iona
dH l a
) t
Wa
t er
Fee
as d wa
fee air hu ter fo
gla d wa midif r diff
t
s
s
and er fo iers, a erent
lab r ult uto labo
o
r
a ra- clav rat
p
t
o
ry v ure w es, g ory e
la
q
ess
e ate ssw uip
l
s
, st r syst are m ment
eam em
ach , suc
g s;
h
i
n
r
e
n
era insin es;
tio g o
n
f
Recommended
Pre-treatment
,
on)
ati
z
i
l
ti
fer
itro ical
v
n
m
F (i he
, IV l bioc ods
s
i
s
h
t
ly
ra
ana ene me
ce ia, g etric
n
e
d
m
equ me to
Your
A s lture s, pho
DNApplications
u
n
lc
io
cel licat
app
RO
Ty p
e1
Your Required ASTM
Water Quality
Turn the disk to the water quality and applications you require and see which system
meets your requirements. You can also view the recommended pre-treatments.
Your Feed
Water
Type 1 Water
pe
ter
y
tor
ora ater rs
b
a
w
rl
ffe
r fo -pure cal bu
e
t
wa ltra logi
eed for u robio nts
f
,
r
ic age
ion te
rat d wa of m of re
e
n
ge fee tion ure
am nt, ara act
Ste ipme , prep anuf
equ tems ia, m
sys med
and
Ty
a
1W
Softener 615S
Deionization
cartridges 615DI
Type 1 Water
Pre
ma para
ves nufa tion o
IC, sels, cture f buf
AA ino of
f
S, I rga rea ers a
CP nic ge nd
, IC
n
m
P-M analy ts, ri edia
S, e tica nsing ,
lec l me of
tro
che thods glass
mis :
try
arYour
ium ® System
pro
VF
RO
6
L
13
16
613
Ma
RN nufa
c
IVF A | D ture
HP , cell NA pu of re
a
LC, cul
ana tur rifica gents
lysi e m tion , mo
s o edia , DN lec
f tr
u
ace , PCR A seq lar b
ele , chr uen iolo
me om ce gy,
nts ato an
a
, el
ect graph lysis,
rop y,
hor
esi
s
Softener
615S
(optional at
>20° dH)
Type 3
ener
Soft
5
61 Sional at
(opt ° dH)
>20
–
RO
DI
61215 E
615DI
RO 61316
(obligatory)
I ca
rtri
dge
Soft
s
(opt ener 6
i
1
at > onal 5S
20°
RO 6
dH)
6121 1316 o
5 ED r
I
–
Ta
–
61215 EDI
system (15 l/h)
Type 3
615
D
–
r
ate
W
p
T
–
RO
E DI
DI
3
UV
ari
u
ari m ® p
um ® ro
bas DI
ic
r
Tap Wate
DI
arium® pro
(1.7–2 l/min)
pro
RO
Type 2
ate
r
e
yp
r
6o
31 DI
1
6 E
trid
RO 215
car
1
S
I
6
15
5D
61
r6
e
n l )
fte na H
So ptio 0° d
(o t >2
a
s
ge
Tap
W
Type 1
m
riu
a
R
ED O
I
–
®
Tap Water
or
S RO 61316
DI
E
5
1
2
1
6
615
Softener l
(optiona dH)
at >20°
–
DNA sequence analysis, IVF (in vitro fertilization),
cell culture media, general biochemical
applications, photometric methods
arium® pro UF
615DI cartridges
r
ne
t
fte
So 5S nal a
61 ptio H)
(o 6° d
>2
RO
EDI
Steam generation, feed water for laboratory
equipment, feed water for ultra-pure water
systems, preparation of microbiological buffers
and media, manufacture of reagents
R
ED O
I
DI
Wa
t er
ate
r
Ty p
e1
Tap
W
615
ts,
,
try emen
s
i
em el
och ace
ctr of tr etry
e
l
is
m
,e
nts alys ctro
age C, an s spe
e
r
s
f HPL
ma
eo
tur aphy, hods,
c
a
f
Your
nu atogr c met
MaApplications
m etri
o
r
ch tom
o
ph
ter
Wa
–
–
ter
Wa
Wa
t er
T ap
–
DI
car
trid
Soft
Recommended
ges
e
(opt ner 6
Pre-treatment
i
1
o
5
at > nal
S
20°
RO 6
dH)
6121 1316 o
5 ED r
I
–
DI
Your Required ASTM
Water Quality
Turn the disk to the water quality and applications you require and see which system
meets your requirements. You can also view the recommended pre-treatments.
Your Feed
Water
Type 2 Water
1
h
suc
nt, es;
e
ipm hin f
equ e mac sing o
y
r
r
ato wa ; rin n
bor glass stems ratio
a
l
e
t
s,
y
ren ave er s gen
iffe utocl wat eam
d
r
a ure s, st
p
l
r fo rs,
ate idifie ultra- vesse
w
y
d
m
r
r
e
u
o
o
Fe air h ter f rat
as d wa d labo
fee ss an
gla
T
e
yp
Ty p
e1
ter
Wa
Reverse osmosis systems
61316 (16 l/h)
613L (50–300 l/h)
Softener 615S
Deionization
cartridges 615DI
Type 1 Water
Tap
W
Ste
equ am g
sys ipme enera
and tems nt, f tion
me , pre eed w , feed
dia par
, m atio ater wate
fo
anu n
r
fac of m r ultr for la
tur icr a-p bo
e o obi ur rat
f re olo e w ory
age gic ate
nts al b r
uff
e rs
R
ED O
I
DI
Wa
t er
ate
r
Ty p
e2
RO
EDI
VF
6 or
615S RO 6131DI
E
Softener l
5
1
2
1
6
(optiona dH)
at >20°
DI
pro ic
um as
ari m® b
u
ari
RO 613L
612
Type 3
Softener
615S
(optional at
>26° dH)
Soften
e
615S r
(option
>20° d al at
H)
Type 3
Type 2
RO 61316
I
5D
–
So
615 ftene
(op S r
>2 tiona
0°
dH l at
)
Ta
–
–
s
ge
DN
cel A seq
app l cult uenc
lica ure e an
tio med aly
ns,
s
pho ia, ge is, IVF
tom nera (in
etr l bi vitr
ic m och o f
eth emi ertili
ods cal zat
ion
),
Tap
W
r
ate
W
p
61
or
16 I
3
61 ED
trid
RO 1215
car
S
I
6
5
5D
61
61
er l )
n
e
a
ft n H
So ptio 0° d
(o t >2
a
15 E
D
I
®
RO
(ob 613
liga 16
tor
y)
RO
E DI
DI
–
Type 1
Manufacture of reagents, electrochemistry,
chromatography, HPLC, analysis of trace elements,
photometric methods, mass spectrometry
y,
log sis,
bio analy ,
ar
cul ce phy is
ole uen ogra hores
t
, m eq
nts A s oma trop
age , DN chr elec
f re ion R, ts,
e o cat , PC en
tur purifi edia elem
fac
nu NA re m race
Ma A | D cultu s of t
RN , cell alysi
IVF LC, an
HP
–
r
pro
s
las
a,
edi of g
m
:
g
nd sin ods y
r
rs a rin th
ffe ents, al me emist
u
b ag tic
h
f
c
o
f re aly ctro
on
ati ure o nic an , ele
r
a
S
t
p
a
Your
c
Pre nufa inorg ICP-M
a ls,
,
P
mApplications
C
e
I
s
ves AAS,
IC,
arium® pro UV
615DI cartridges
ate
®
um
ari
arYour
ium ® System
pro
UF
1W
615
pe
–
–
r
Tap Wate
Wa
t er
Ty
r
6o
s
31 I
ge
61 ED
rid
RO 1215
art
S
Ic
6
15
5D
61
r6
ne l )
fte na H
So ptio 0° d
(o t >2
a
–
DI
car
trid
Recommended
Soft
ges
(opt ener 6Pre-treatment
1
i
at > onal 5S
20°
RO 6
dH)
6121 1316 o
5 ED r
I
–
DI
Your Required ASTM
Water Quality
–
r
ate
W
p
Ty p
e1
Turn the disk to the water quality and applications you require and see which system
meets your requirements. You can also view the recommended pre-treatments.
Your Feed
Water
RO
ate
r
Tap Water
Type 3 Water
RO
EDI
DI
–
Ta
1
Feed water for different laboratory equipment, such
as air humidifiers, autoclaves, glassware machines;
feed water for ultra-pure water systems; rinsing of
glass and laboratory vessels, steam generation
T
e
yp
ter
Wa
arium® pro
(1.7–2 l/min)
61215 EDI
system (15 l/h)
Reverse osmosis systems
61316 (16 l/h)
613L (50–300 l/h)
Softener 615S
Deionization
cartridges 615DI
Type 1 Water
Fee
as d wa
fee air hu ter fo
gla d wa midif r diff
ss a ter
e
ie
nd for rs, au rent l
a
lab ult
r
ora a- toclav borat
tor pur es, ory
y v e w gla eq
ess
els ater s sswar uipm
, st
e
eam ystem e ma nt, su
gen s; rin chine ch
era sin s;
tio g o
n
f
6
L
31
613
RO
RO
61
R
ED O
I
Wa
t er
DI
ate
r
Tap
W
So
615ftener
(op S
>26 tiona
° dH l at
)
Ta
S
6 oft
(o 15S ener
>2 ptio
0° na
dH l a
) t
Ta
r
ate
W
p
Ma
chr nufa
c
pho omat ture
tom ogr of r
etr aphy eage
ic m , H nt
eth PLC s, ele
ods , an ctr
, m aly och
ass sis o em
spe f tr istr
ctr ace y,
om
etr elem
y
ent
s,
Type 3
Reverse osmosis systems
61316 (16 l/h)
613L (50–300 l/h)
Softener 615S
Deionization
cartridges 615DI
Type 1 Water
RO
r
p
W
ate
r
61215 EDI
system (15 l/h)
Type 3
Manufacture of reagents, molecular biology,
RNA | DNA purification, DNA sequence analysis,
IVF, cell culture media, PCR, chromatography,
HPLC, analysis of trace elements, electrophoresis
–
Type 2
ate
21
61
16 )
613atory
O
R lig
(ob
r
ne
fte
So 5S al at
61 ption H)
(o 0° d
>2
I
D
5E
),
ion
zat
tili
fer
itro al
n v mic
F (i he
, IV ioc ds
ysis al b etho
nal ner
e a , ge ric m
enc dia met
equ me to
A s ure pho
DN l cult ions,
cel licat
app
–
DI
615
1W
–
arium® pro
(1.7–2 l/min)
UF
or
615S RO 61316 I
Softener l
D
E
5
1
612
(optiona dH)
at >20°
Type 1
Preparation of buffers and media,
manufacture of reagents, rinsing of glass
vessels, inorganic analytical methods:
IC, AAS, ICP, ICP-MS, electrochemistry
arium® pro DI
arium® basic
615DI cartridges
pe
pro
–
Ty
®
um
arYour
ium ® System
pro
UV
ory
rat
bo ater fers
a
l
w
r
f
r fo ure l bu
ate tra-p ogica
w
ed r ul biol ts
n
o
, fe fo
on ater micr reage
i
t
ra d w of of
e
n
n
e
ge fe tio ure
am nt, ara act
Your
Ste ipme , prep anuf
u
s
m
eqApplications
tem ia,
sys med
and
arium® pro VF
615
ari
RO
EDI
Wa
t er
–
–
DI
car
trid
Soft
Recommended
ges
e
(opt ner 6
Pre-treatment
i
1
o
5
at > nal
S
20°
RO 6
dH)
6121 1316 o
5 ED r
I
–
DI
Ty p
e1
RO
EDI
Your Required ASTM
Water Quality
–
615DI cartridges
or
615S RO 61316 I
Softener l
D
61215 E
(optiona dH)
at >20°
–
–
r
6o
31 I
s
ge
61 ED
rid
RO 215
art
S
Ic
61
15
5D
61
r6
ne l )
fte na H
So ptio 0° d
(o t >2
a
Ty p
e3
RO
EDI
DI
Turn the disk to the water quality and applications you require and see which system
meets your requirements. You can also view the recommended pre-treatments.
Your Feed
Water
r
Tap Wate
r
Tap Wate
–
r
ate
W
2
pe
DI
Ty
r
ate
W
p
Ta
Type 2 Water
T
3
RO
EDI
DI
DI
RO
EDI
Tap
W
Your Required ASTM
Water Quality
Ty p
e1
ate
r
–
–
615
D
I
car
trid
Sof
ges
(op tener 6
at >tional 15S
20°
d H)
Wa
t er
DI
R
ED O
I
R
ED O
I
DI
ate
r
Tap
W
Type 1 Water
3L
61
Ty p
e
Type 3
1W
a
t er
Ta
r
Pre
ma para
ves nufa tion o
IC, sels, cture f buf
AA ino of
f
S, I rga rea ers a
CP nic ge nd
, IC
n
m
P-M analy ts, ri edia
S, e tica nsing ,
lec l me of
tro
che thods glass
mis :
try
,
y,
nts
istr leme
hem e e
roc f trac ry
t
ect
, el is o me
nts alys ctro
age , an spe
f re HPLC ass
m
eo
tur aphy, hods,
fac
et
nu ogr
Ma omat etric m
chr tom
pho
r
ate
W
p
ate
RO
pe
Tap Water
Ty
VF
16
613
DNA sequence analysis, IVF (in vitro fertilization),
cell culture media, general biochemical
applications, photometric methods
61215 EDI
system (15 l/h)
pro
DI
61215 E
RO
Type 2
ium ®
Steam generation, feed water for laboratory
equipment, feed water for ultra-pure water
systems, preparation of microbiological buffers
and media, manufacture of reagents
Ma
RN nufa
c
IVF A | D ture
HP , cell NA pu of re
a
LC, cul
an tu rifica gent
a
l
ysis re me tion, s, mo
of dia, DNA lecu
t
r
a
ce PCR, sequ lar bio
ele chr
me om ence logy,
n
t
s, e atog analy
lec rap sis,
tr
hy
o
p
hor ,
esi
s
arium® pro
(1.7–2 l/min)
r
ne
t
fte
So 5S nal a
61 ptio H)
(o 6° d
>2
h
suc
nt, es;
e
ipm hin f
equ e mac sing o
y
r
r
ato wa ; rin n
bor glass stems ratio
a
l
e
t
s,
y
ren ave er s gen
iffe utocl wat eam
d
r
a ure s, st
p
l
r fo rs,
ate idifie ultra- vesse
w
y
d
m
r
Your
r
e
u
o
o
Fe air h ter f rat
a
bo
asApplications
d w d la
fee ss an
gla
615DI
RO
ener
Soft
5
61 Sional at
(opt ° dH)
>20
Type 1
ari
um ® System
arYour
ium ® pro
bas DI
ic
UV
–
pro
Softener
615S
(optional at
>20° dH)
®
RO 61316
(obligatory)
um
–
ari
DI
car
trid
Soft
Recommended
ges
e
(opt ner 6
Pre-treatment
i
1
o
5
at > nal
S
20°
RO 6
dH)
6121 1316 o
5 ED r
I
–
–
615
ar
Your Feed
Water
–
–
RO
6
6121 1316 o
5 ED r
I
–
arium® pro UF
r
6o
31 I
s
ge
61 ED
rid
RO 215
art
S
Ic
61
15
5D
61
r6
ne l )
fte na H
So ptio 0° d
(o t >2
a
Turn the disk to the water quality and applications you require and see which system
meets your requirements. You can also view the recommended pre-treatments.
1W
615DI cartridges
316 or
615S RO 61 EDI
Softener l
61215
(optiona dH)
at >20°
–
r
ate
W
p
r
Tap Wate
–
Ta
e
yp
ter
Wa
Type 3
Reverse osmosis systems
61316 (16 l/h)
613L (50–300 l/h)
Softener 615S
Deionization
cartridges 615DI
Type 3 Water
DI
R
ED O
I
um
®
pro
VF
Type 3
pe
1W
ate
ate
r
y,
log sis,
bio analy ,
ar
cul ce phy is
ole uen ogra hores
t
, m eq
nts A s oma trop
age , DN chr elec
f re ion R, ts,
e o cat , PC en
tur purifi edia elem
fac
nu NA re m race
Ma A | D cultu s of t
RN , cell alysi
IVF LC, an
HP
r
Reverse osmosis systems
61316 (16 l/h)
613L (50–300 l/h)
Softener 615S
Ty
Tap
W
r
6o
s
31 I
ge
61 ED
rid
RO 1215
art
S
Ic
6
15
5D
61
r6
ne l )
fte na H
So ptio 0° d
(o t >2
a
ari
Ty p
e
61215 EDI
system (15 l/h)
1W
a
t er
,
ass
dia f gl
o
me
:
nd sing ods y
r
rs a rin th
ffe ents, al me emist
bu
of reag alytic troch
f
c
on
ati re o c an , ele
S
par ctu ani
Pre nufa inorg ICP-M
ma sels, ICP,
ves AAS,
IC,
Type 3
Manufacture of reagents, electrochemistry,
chromatography, HPLC, analysis of trace elements,
photometric methods, mass spectrometry
DN
cel A seq
app l cult uenc
lica ure e an
m
a
t
i
o
ns, edia lysis,
pho , ge IVF
to ne
(i
n
m
etr ral bi vitr
ic m och o f
e
e
tho emic rtiliz
ati
ds al
on)
,
Type 2
Ste
equ am g
sys ipme enera
and tems nt, f tion
me , pre eed w , feed
dia par
, m atio ater wate
fo
anu n
r
fac of m r ultr for la
tur icr a-p bo
e o obi ur rat
f re olo e w ory
age gic ate
nts al b r
uff
ers
Deionization
cartridges 615DI
Type 1 Water
Feed water for different laboratory equipment, such
as air humidifiers, autoclaves, glassware machines;
feed water for ultra-pure water systems; rinsing of
glass and laboratory vessels, steam generation
RO 613L
Softener
615S
(optional at
>26° dH)
RO
EDI
DI
RO 61316
Your
Applications
r
ate
1W
pe
DI
Ty
r
ate
pW
15 E
–
ari
um ®
612
–
RO 6
6121 1316 o
5 ED r
I
5
UF
61
DI System
Your
pro
)
Soften
e
615S r
(option
>20° d al at
H)
arium® pro
(1.7–2 l/min)
Wa
t er
Ta
615
D
I
car
trid
Sof
ges
(op tener 6
at >tional 15S
20°
dH)
RO
–
–
ory
I
oD
® pr
c
um asi
ari m® b
u
ari
–
arium® pro UV
r
6o
s
31 I
ge
61 ED
rid
RO 1215
art
S
Ic
6
15
5D
61
r6
ne l )
fte na H
So ptio 0° d
(o t >2
a
–
So
Your Feed
615 ftene
Water
(op S r
RO
>2 tiona Recommended
(ob 613
0°
dH l aPre-treatment
liga 16
t
)
t
Tap Water
ate
r
–
Tap
W
Your Required ASTM
Water Quality
Ty p
e2
–
RO
EDI
Turn the disk to the water quality and applications you require and see which system
meets your requirements. You can also view the recommended pre-treatments.
–
Type 1
DI
615DI cartridges
6 or
615S RO 6131DI
Softener l
61215 E
(optiona dH)
at >20°
–
–
Ta
r
ate
W
p
RO
EDI
DI
r
Tap Wate
The arium® Family
at a Glance
Sartorius Stedim Biotech GmbH
August-Spindler-Strasse 11
37079 Goettingen, Germany
Phone +49.551.308.0
Fax +49.551.308.3289
www.sartorius-stedim.com
Specifications subject to change without notice.
Printed in Germany on paper that has been
bleached without any use of chlorine. | W
Publication no.: SL-1531-e11092
Order no.: 85032-537-71