Transformer solutions across the grid
Transcription
Transformer solutions across the grid
Transformer solutions across the grid Distribution Transformers / Worldwide Support / Customer-Focused Operations / Reliable Performance / Committed to meeting every transformer need. Everything is under (quality) control Generating, distributing and controlling electricity requires proven expertise, in-depth understanding, worldwide experience and a commitment to customer responsiveness. That’s what you get with Prolec GE. Our products are developed, tested, deployed and continually improved with a focus on delivering reliable, customer-focused performance. And a key to that performance is a relentless commitment to quality. Our quality systems are based on solid fundamental processes. Key elements of our Total Quality Model include: These world-class quality systems ensure reliable, safe, durable, and environmentally responsible products that meet real customer needs. Enhancing these sound fundamentals with ongoing research and development, global best practices, and continuous process improvement gives you world-class performance in every product and every procedure. Our processes and products have been certified as meeting or exceeding major international quality standards, including: • ISO 9001 – 2000 • ISO 14001 – Environmental Certifications • UL TQM – Total Quality Management TPS – Toyota Production System Thanks to our dedication to quality, the entire Prolec GE line performs precisely as promised. Helping you generate, distribute and control electricity anywhere on the planet. KDS – Knowledge Dispersion System Tell us what you need, and we’ll deliver for you. Six Sigma Tools Better quality means better performance “The one thing you never get from Prolec GE is surprises. They do what they say they’ll do and their products perform as promised.” Single-Phase Pole-Type Transformers Optional features & accessories Prolec GE designs and manufactures a complete line of single-phase pole-type distribution transformers for installation on utility overhead systems. These highly reliable transformers are available in a wide variety of ratings and accessory combinations. We utilize state-of-the-art technology in our design and manufacturing systems, supported by our ISO-9001 certified processes and quality assurance programs, to provide you with reliable and cost-effective transformer products matched to your system requirements. Standard features • Broad selection of design efficiencies to meet specific customer applications and new DOE minimum requirements • Automatic pressure relief valve • High-voltage taps with external tank mounted no load tap changer • Dual high-voltage ratings (not available with taps) • Connectors for grounding • Stencils and labels according to customer requirements • External tank mounted high-voltage lightning arrester • Low-voltage circuit breaker with reset (and optional overload signal light) • Internal high-voltage expulsion fuse • Under oil arrester • External low-voltage surge arrester • Interlaced secondary windings (through 50 kVA ratings) • RUS compliant 1 bushing designs with double hanger bracket configuration (through 50 kVA) • Stainless steel tank, cover, clamping band • Extra creep options for high-voltage bushings • Variety of features available for wildlife protection • Magnex™ Tests • All transformers are tested in strict accordance with the latest revision of applicable ANSI™, IEEE™, NEMA, and RUS with test reports available by serial number of the transformer • Meets or exceeds current RUS, NEMA and ANSI Standards C57.12.00, ANSI C57.12.20 as applicable Routine tests are: • Mild steel tank with welded lifting lugs and hanger • Leak test brackets for direct-to-pole mounting • Polarity and phase relation • Single piece clamped cover band meets cover • Resistance retention requirements of applicable ANSI standards • No-load losses and excitation current • Electrostatically applied polyester powder paint • Load losses and impedance system for superior corrosion protection • Applied voltage • High-voltage porcelain cover-mounted bushings • Induced voltage (wall mounted for units with high voltage 4160 or below) • Full wave impulse • Tank wall mounted porcelain or polymer low-voltage • Ratio test bushings • Tin-plated bronze terminals for connection to copper or aluminum • Low-voltage ground provisions • Tank ground provision • Insulated cover for wildlife protection • Laser engraved aluminum nameplate • Non-PCB insulating oil • KVA rating on tank wall • Arrester mounting nuts welded to tank (single bushing designs) • One HV bushing with tank ground strap for grounded wye applications or two HV bushings for wye applications • Recessed tank bottom Porcelain high-voltage bushings (expulsion fuse internally mounted in self-protected unit) High-voltage lightning arrester* Oil fill plug Cover band Welded hanger brackets Low-voltage circuit breaker* Lifting lugs Low-voltage bushings Ground connector Copper ground strap De-energized operation tap changer Nameplate * Accessories for self-protected units Popular configurations Double hanger bracket one highvoltage bushing conventional unit. Single hanger bracket two highvoltage bushings conventional unit. Single hanger bracket one highvoltage bushing self protected unit. Standard sizes and voltages • kVA: 10, 15, 25, 37.5, 50, 75, 100, 167 • HV ratings: 4160GrdY/2400 to 34500GrdY/19920 or 2400 to 19920 (Dual voltages available) • BIL: 60 kV to 150 kV • LV ratings: 240/120 and 480/240 Please contact your GE sales representative for kVA sizes and voltage ratings not listed. For more information contact your local GE Sales Representative or visit our website at www.prolecge.com Phone: Toll free 1 800-437-7653 (US & Canada) / +52 (81) 8030-2341 (Mexico) / Fax: +52 (81) 8030-2323 or 2325 1PHPTTR-0111-03 Single-Phase Pad-Mounted Transformers • Recessed tank bottom • Electrostatically applied polyester powder paint system with urethane top coat for superior corrosion protection • Removable sill Optional features & accessories Prolec GE manufactures a complete line of single-phase pad-mounted distribution transformers designed to provide the features, performance and aesthetics needed for modern underground residential applications. We utilize state-of-the-art technology in our design and manufacturing systems, supported by our ISO-9001 certified processes and quality assurance programs. Standard features • Meets or exceeds applicable ANSI, NEMA, and RUS standards, including ANSI C57.12.00, C57.12.28 and C57.12.38 (enclosure integrity and finishing systems) • Crowned tank top to prevent water retention • Removable flip-top hood opens 180° for easy access with stainless steel hinge pins • Externally clamped high-voltage bushing wells for loop feed or radial feed operation • Externally clamped low-voltage threaded stud bushings • Automatic relief device for internal pressures • Penta-head security bolt with padlock provision (Hexa-head bolt available) • NEMA safety labels • Externally clamped low-voltage bushings • Tank ground provisions • Laser engraved aluminum nameplate • Oil fill/level top plug and bottom drain plug • Broad selection of design efficiencies to meet specific customer applications and new DOE minimum requirements • High-voltage no load tap changer • Dual high-voltage ratings (not available with taps) • Complete stainless steel tank and cabinet or combination of components with mild steel and stainless steel • High-voltage, load-break 2 positions or sectionalizing switch • Multiple fusing options and combinations, including internal and external expulsion fuse in series with isolation link or partial range current limiting fuse • Low-voltage circuit breaker • Under oil arrester • Drain valve with sampling device • Hold-down cleats • Connectors for ground pads • Stencils and labels according to customer needs • Magnex™ (For optional accessories or features not listed above, please contact your GE sales representative). Tests • All transformers are tested in strict accordance with the latest revision of applicable ANSI™, IEEE™, NEMA, and RUS with test reports available by serial number of the transformer Routine tests are: • Polarity and phase relation • Resistance • No-load losses and excitation current • Load losses and impedance • Applied voltage • Induced voltage • Full wave impulse • Ratio test • Leak test Lock mechanism Flip-top hood opens 180° Laser engraved nameplate NEMA safety labels Pressure relief valve Externally accessible expulsion fuse with drip cup Fill plug Parking stand for elbow connectors High-voltage bushing wells Low-voltage threaded stud bushings Removable ground strap Tank ground provisions Drain plug Padlock provision Removable sill Mini-Pad (ANSI Type II) Prolec GE’s Mini-Pad transformers are designed for single-phase residential underground applications where aesthetics and size are important. They meet all applicable ANSI Standard C57.12.38 Type II requirements for cross-cable configuration. Transformers feature loop feed two bushing dead-front primary designs. Ratings are 10 kVA through 167 kVA single-phase, 34.5 kV GrdY and below. Standard voltage ratings as well as dual voltages are offered. Maxi-Pad (ANSI Type I) Prolec GE’s Maxi-Pad transformers offer the same tamper-resistant features and accessibility as the Mini-Pad transformer while allowing straight cable configuration with only a small increase in height. The Maxi-Pad is available in 10 kVA through 167 kVA with the same broad range of voltages and optional accessories as the Mini-Pad. This product meets ANSI Standard C57.12.38 Type I requirements. Standard sizes and voltages • kVA: 10, 15, 25, 37.5, 50, 75, 100, 167 • HV ratings: 4160GrdY/2400 to 34500GrdY/19920 or 2400 to 19920 (Dual voltages available) • BIL: 60 kV to 150 kV • LV ratings: 240/120 and 480/240 Please contact your GE sales representative for kVA sizes and voltage ratings not listed. Standards and certifications available For more information contact your local GE Sales Representative or visit our website at www.prolecge.com Phone: Toll free 1 800-437-7653 (US & Canada) / +52 (81) 8030-2341 (Mexico) / Fax: +52 (81) 8030-2323 or 2325 1PPMTR-1011-03 Three-Phase Pad-Mounted Transformers • Designed, manufactured and tested in accordance with the latest ANSI standards Optional features & accessories High-grade materials, combined with sophisticated engineering design systems, are key elements of a transformer that will deliver years of highly reliable service. • Broad selection of design efficiencies to meet specific customer applications and the new DOE efficiency requirements • 50 Hz • Type II insulating mineral oil • High-fire point fluid, such as silicone, hydrocarbon or vegetable fluids • 55° and 55°/65° C average winding rise • Copper and aluminum windings available • Dual high-voltage ratings • Internal expulsion fuses • Current limiting fuses • Internal oil-immersed partial range current-limiting fuses • Bayonet fuse holders with and without flapper • Non-loadbreak and loadbreak dry-well fuseholders • Internal oil switch (radial or loop) • Under oil internal arresters • Low-voltage molded-case circuit breaker • Seismic Zone III and IV • Stainless steel tank and cabinet construction • Special colors • RUS accepted • Compliance with Canadian Standards (CSA) • Flip-top cabinet Standard features Tests • • • • • • • • Each transformer receives all standard commercial tests in accordance with ANSI C57.12.90 (latest revision), with test reports available by serial number of the transformer. Prolec GE offers a complete line of liquid-filled ThreePhase Pad-Mounted distribution transformers that meet applicable ANSI™/IEEE™ standards. With high voltages up to 34.5 kV and ratings up to 5,000 kVA (ONAN), Prolec GE compartmental-type Three Phase Pad-Mounted Commercial Transformers are designed for outdoor installation on a concrete pad and provide underground power distribution to commercial, industrial and institutional loads. • • • • • • • • • • 60 Hz operation 65° C average winding rise Radial & loop feed arrangements Dead and live front type of HV terminals HV BIL 45 – 150 kV (Dead Front) 200 kV (Live Front) LV BIL 30 – 60 kV Three-point latching of low-voltage door High-voltage door, which can be opened only after the low-voltage door is opened Rigid steel partition Transformer tank welded from cover to base Permanent nameplate One-inch NPT pipe cap filling provision ANSI tank ground pads One-inch drain valve and sampler Automatic pressure-relief valve (35 SCFM) Tap changer with (2) 2.5% full capacity taps above and below nominal One 10”x18” (or 14”x25”) hand hole in transformer tank cover Painted olive-green color (Munsell 7GY 3.29/1.5) • Resistance tests of all windings • Ratio tests on the rated voltage and all tap connections • Polarity and phase relation tests at rated voltage • No load loss at rated voltage • Exciting current at rated voltage • Impedance and load losses • Applied voltage test • Induced voltage test • Full-wave impulse test • Mechanical leak test ANSI is a registered trademark of American National Standards Institute, Incorporated. IEEE is a registered trademark of the Institute of Electrical Electronics Engineers, Inc. Standard voltages Standard ratings Standard Primary Voltage Ratings Minimum BIL (kV) 2400 4160 4800 7200 7620 12000 12470 13200 13800 16340 45 60 60 75 75 95 95 95 95 95 Grounded Wye 4160GrdY/2400 12470GrdY/7200 13200GrdY/7620 13800GrdY/7970 22860GrdY/13200 23900GrdY/13800 24940GrdY/14400 34500GrdY/19920 65 95 95 95 125 125 125 150 Standard kVA Ratings 45 225 1000 75 300 1500 500 2000 Delta or Wye 112.5 150 750 2500 Overall typical dimensions for reference kVA Height Width Depth Typ Weight (Lb) Typ Gal Oil 75 112.5 150 225 300 500 750 1000 1500 2000 2500 64 64 64 66 67 68 75 78 82 86 87 46 46 47 50 53 62 72 75 82 85 88 65 65 65 67 68 70 72 75 83 89 96 2,512 2,729 2,895 3,499 3,866 4,958 6,590 7,647 9,888 11,891 13,794 136 145 145 164 171 203 272 312 368 433 487 For kVAs not listed, contact factory. Dimensions and weights are approximate and subject to change without notice and should not be used for construction purposes. Standards and certifications available For more information contact your local GE Sales Representative or visit our website at www.prolecge.com Phone: Toll free 1 800-437-7653 (US & Canada) / +52 (81) 8030-2341 (Mexico) / Fax: +52 (81) 8030-2323 or 2325 3PPMTR-0914-04 Flip-Top Cabinet After discussions with numerous customers, Prolec GE is now offering as an option a flip-top cabinet for commercial transformers. Please note information below. Design Overview • Standard for 3-Phase Pad transformers from 45 kVA to 2500 kVA • Opening Angles: 45°, 110° (max) Advantages The new cabinet design has a cover that can be flipped up, with the following benefits: • Enhanced range of access to front-plate components • Improved safety for O&M personnel • Greater visibility, since the open cover allows more sunlight in the cabinet area • Shorter product height Applicable Standards • IEEE C57-12-00 • IEEE C57-12-28 • IEEE C57-12-34 For more information contact your local GE Sales Representative or visit our website at www.prolecge.com Phone: Toll free 1 800-437-7653 (US & Canada) / +52 (81) 8030-2341 (Mexico) / +971 4 429 6101 (Middle East) Fax: +52 (81) 8030-2323 or 2325 FTTR-0914-02 Transformer Solutions for Arc Flash Risks Prolec GE has developed options for reducing arc flash risks to personnel responsible for installation, operation and maintenance routines during transformer operation. Typically, in renewable applications, transformers are very close to the generation point, which justifies precautionary measures against an arc flash event. Our solutions focus on the safety of personnel by offering several packages for added protection. Tamper-proof pad lockable enclosures for externally-accessible accessories Typical Operation and Maintenance activities performed on a transformer for renewable applications: • Switching transformers in and out of the collection circuit • Routinely taking oil samples for dissolved gas analysis testing • Monitoring tank pressure and adding gas as needed • Performing infrared temperature scans of the HV and LV connections Available packages Package Features Value point Basic Accessories externally accessible with Provides a safe access padlock provision for O&M routines. - Drain valves, liquid level, liquid temperature and pressure vacuum gauges, load break switch Off-load Molded circuit breakers installed in Minimize risk when plexiglass barrier in LV compartment de-energizing transformer from IR Windows for thermo scanning generation source. Monitoring capabilities supported via Mitigate the hazard by Monitoring accessories with contact switches, remote monitoring. and SCADA digital communication signals Standards and certifications available Low Voltage Molded circuit breaker installed in a plexiglass barrier For more information contact your local GE Sales Representative or visit our website at www.prolecge.com Phone: Toll free 1 800-437-7653 (US & Canada) / +52 (81) 8030-2341 (Mexico) / +971 4 429 6101 (Middle East) Fax: +52 (81) 8030-2323 or 2325 AFTR-0112-01 Prolec GE Step Up Transformers for Solar Energy Applications Value Added Concept Features Value point Step Up Increased margin for core over excitation, withstanding high magnetizing inrush currents Prevent core saturation or ferroresonance Electronic Protection Network Protection Prolec GE has developed Step Up Transformers designed specifically for Solar Power Generation applications. Operational characteristics include thermal design for higher ambient temperature ranges and core and coils designed for step up application with an electrostatic shield for protection against electrical noise coming from the grid and the inverter. Various efficiency levels are available to match project financial requirements, including ultra-efficient amorphous metal cores. Product scope / Standard features • 700 kVA and 1000 kVA (See Table 1) • High Voltage ratings: 12470 V, 24940 V & 34500 V (See Table 2) • Low voltage rating: 480Y/277 (See Table 2) • HV connection: DELTA • LV connection: Wye • 60 Hz operation • 65°C winding temperature rise • HV tap changer for (2) 5% full capacity tape above and below rated voltage • Loop feed dead front HV terminals • Cooling Class: ONAN • % Impedance: 5.75% +/- 7.5% • ANSI 70 Paint Finish • Altitude of operation up to: 3300 ft • Bayonet expulsion fuse plus partial range current-limiting fuses • Built to all applicable IEEE standards * Solutions for Arc Flash Electrostatic Shield Accessories externally accessible and monitoring of the transformer Provide a pathway to ground for any residual resonance Prevent capacitive coupling between the grid and capacitive banks of the inverter Mitigate the hazard during the performance of the O&M routines * Detailed information in PGE catalog: Transformer solutions for Arc Flash Risks. Special / Optional features • • • • • • • • • • • • • • From: 500 kVA to 2000 kVA Other connections available LV ratings: from 208 V to 600 V HV BIL: from 95 kV to 200 kV* LV BIL: from 30 kV to 60 kV 50 Hz operation 55°C winding temperature rise Bayonet fuse holders with flappers High fire point fluids, such as silicone, hydrocarbon or vegetable fluids Internal oil switch (radial or loop) Under oil internal arresters Seismic designs IBC Certified Stainless steel tank and cabinet construction Optional colors * 200 kV BIL on Coil Standards and certifications available Table 1 Overall typical dimensions for reference Table 2 Standard ratings kVA A* Height B* Width C* Depth WEIGHT (lb) Core Material kVA HV Ratings BIL 700 1000 700 1000 70 75 75 80 70 90 85 90 80 80 80 80 7,000 9,000 8,000 11,000 Silicon Steel Amorphous Metal 700 1000 12470 DELTA 24940 DELTA 34500 DELTA 95 150 150 LV Ratings 480Y/277 * Dimensions in inches ** Dimensions and weight are approximate and subject to change without notice and should not be used for construction purposes *** Other ratings available upon request For more information contact your local GE Sales Representative or visit our website at www.prolecge.com Phone: Toll free 1 800-437-7653 (US & Canada) / +52 (81) 8030-2341 (Mexico) / +971 4 429 6101 (Middle East) Fax: +52 (81) 8030-2323 or 2325 SETR-0112-01 Substation Transformers Optional features & accessories Prolec GE offers a complete line of liquidfilled distribution transformers that meet current applicable ANSI™ / IEEE™ standards. With high voltages up to 34.5kV and ratings up to 15 MVA (ONAN), Prolec GE primary and secondary substation transformers are used in a wide range of utility, commercial and industrial applications. High-grade materials, combined with state of the art technology in our design and manufacturing systems, are key elements of a transformer that will deliver years of high reliability service. Prolec GE Primary and Secondary Substation Transformers meet all of your industrial applications for electric distribution. Standard features • Insulating mineral oil • 60 Hertz operation • Externally operated de-energized tap changer with (2) 2.5% full capacity taps above and below nominal • 65° C average winding rise • Side-mounted bushings • HV and LV flange connections • Pressure-vacuum gauge • Top filter press valve provision • Liquid level gauge • Liquid temperature gauge • Pressure test valve • ANSI grounding pad • Drain / filter valve with sampling device • Tank lifting lugs • Corrosion resistant nameplate • ANSI 61 paint finish, 5 mils thickness • ANSI 70 paint finish, 5 mils thickness • Hydran provision (above 7.5 MVA) • High-fire point fluid, such as silicone, hydrocarbon or vegetable fluids. (up to 10 MVA) • 55° C 55/65° C average winding rise • Forced air cooling • Forced air cooling with 2 stages (from 7.5 MVA and up to 15 MVA) • Future fan wiring and control • Removable radiators • Pressure relief device • Winding temperature device • Sudden pressure relay with or without seal in • Devices with alarm contacts • Top filter press valve • HV & LV air terminal compartments • HV lightning arresters in ATC • Current transformers • Neutral grounding resistor • Special impedances • Low losses • Special environment (i.e: classified areas) • Special / low sound level • 50 Hertz • Seismic zone III and IV • IBC/CBC certified product line up to 5 MVA • Retrofit to specific dimensions • Non-standard loading conditions such as harmonic loading or specified K-factor • Stainless steel removable radiators • Galvanized steel removable radiators • Special paint for marine ambient • Special paint thickness • Special colors • CSA compliance • Other special features upon request Tests Each transformer receives all standard commercial tests in accordance with ANSI C57.12.90 (latest revision), with test reports available by serial number of the transformer. Routine tests include: • Resistance tests of all windings • Ratio tests on the rated voltage and all tap connections • Polarity and phase relation tests at rated voltage • No load loss at rated voltage • Exciting current at rated voltage • Impedance and load losses • Applied voltage test • Induced voltage test • Full wave impulse test ANSI is a registered trademark of American National Standards Institute, Incorporated. IEEE is a registered trademark of the Institute of Electrical Electronics Engineers, Inc. Pressure-relief device Sudden-pressure relay Lifting lugs Fill plug Vacuum pressure gauge Filter press valve gauge Winding temperature gauge Liquid-level gauge Liquid temperature gauge Tap changer Radiators Nameplate Drain valve Control box Overall typical dimensions for reference Standard ratings (ONAN) Oil Filled; 65˚C Rise; BIL 95 kV Standard kVA Ratings kVA Height Flange - Flange Depth Total Weight (Lb) 750 1000 1500 2000 2500 3000 3750 5000 7500 10000 12000 15000 90 90 95 95 95 100 105 105 120 130 130 130 50 60 60 65 65 70 70 75 80 80 85 130 60 70 75 75 80 90 90 95 110 135 135 155 6,400 7,300 9,500 11,400 13,100 15,800 18,200 22,000 29,000 32,800 38,200 70,000 225 300 500 750 1000 1500 2000 2500 3750 5000 7500 10000 12000 15000 Standard voltages (V) Standard Primary Voltage Ratings * 2400 4160 4800 6900 7200 12000 12470 13200 13800 23000 34500 Other Standard Secondary Voltage Ratings kVA 750 1000 1500 2000 2500 3000 3750 5000 7500 10000 12000 High Fire Point Fluid; 65˚C; BIL 95 kV Depth Total Weight (Lb) Height Flange - Flange 85 85 85 90 95 100 100 100 110 115 125 55 60 60 65 70 70 75 80 80 90 95 60 75 85 85 90 95 95 105 125 135 135 6,300 7,400 9,500 11,900 13,400 15,700 18,300 22,100 30,400 33,000 35,700 * 208Y * 240 480 600 2400 4160Y 4800 12000 12470 13200 13800 Other Standards and certifications available For kVAs not listed, contact factory. Dimensions and weights are approximate and subject to change without notice and should not be used for construction purposes. For more information contact your local GE Sales Representative or visit our website at www.prolecge.com Phone: Toll free 1 800-437-7653 (US & Canada) / +52 (81) 8030-2341 (Mexico) / Fax: +52 (81) 8030-2323 or 2325 SBTR-1011-02 Substation Transformers up to 69 kV • • • • • • • Corrosion resistant nameplate ANSI 61 paint finish, 5 mils thickness ANSI 70 paint finish, 5 mils thickness Hydran Provision Removable radiators 60 Hertz operation 65° C average winding rise Optional features & accessories Prolec GE offers a complete line of liquid-filled distribution transformers that meet current applicable ANSI™ / IEEE™ standards. In addition to the already existing Substation Transformers product line Prolec GE now offers its brand new transformers, with high voltages from 34.5 kv to 69 kV and ranging from 5 MVA to 12 MVA (ONAN). These type of transformers are used in a wide range of utility, and industrial applications. High-grade materials, combined with state of the art technology in our design and manufacturing systems, are key elements of a transformer that will deliver years of high reliability service. Prolec GE Substation Transformers meet all of your industrial applications for electric distribution. Standard features • Insulating mineral oil • Externally operated de-energized tap changer with (2) 2.5% full capacity taps above and below nominal • High voltage cover-mounted bushings • Low voltage cover and side-mounted bushings • Pressure-vacuum gauge • Top filter press valve provision • Liquid level gauge • Liquid temperature gauge • Winding temperature device • Pressure relief device • Pressure test valve • ANSI grounding pad • Drain / filter valve with sampling device • Tank lifting lugs • • • • • • • • • • • • • • • • • • • • • Forced air cooling Future fan wiring and control Winding temperature device (additional) Sudden pressure relay with or without seal in Devices with alarm contacts Top filter press valve Low voltage flange connections Low Voltage air terminal compartments Current transformers (additional) Neutral grounding resistor Special impedances and low losses Special environment (i.e: classified areas) Special/Low sound level 50 Hertz Seismic zone III and IV and IBC Stainless and galvanized steel removable radiators Special paint for marine environment Special colors and paint thickness CSA compliance Other special features upon request 55° C, 55/65° C average winding rise Tests Each transformer receives all standard commercial tests in accordance with ANSI C57.12.90 (latest revision), with test reports available by serial number of the transformer. Routine tests include: • • • • • • • • • Resistance tests of all windings Ratio test on all tap positions Polarity and phase relation tests at rated voltage No load loss at rated voltage Exciting current at rated voltage Impedance and load losses Applied voltage test Induced voltage test Full wave impulse test ANSI is a registered trademark of American National Standards Institute, Incorporated. IEEE is a registered trademark of the Institute of Electrical Electronics Engineers, Inc. High voltage bushings Current transformers connection Pressure relief device Low voltage bushings Lifting lugs Winding temperature gauge Liquid temperature gauge Fill valve Control box Ground connection Drain valve Overall dimensions for reference Weight (Lbs.) Volume (Gallons) and Dimensions (Inches) kVA Height Large Depth Oil Weight 5000 7500 10000 12000 154 158 167 164 180 175 263 263 150 185 157 177 2,400 2,800 3,200 3,200 48,000 60,000 74,000 77,000 Standard Primary Voltage Ratings, kV Standard Secondary Voltage Ratings 46 69 4160 Y / 2400 V 12470 Y / 7200 V 13200 Y / 7620 V 13800 Y / 7960 V 23000 Y / 13280 V For kVAs not listed, contact factory. Dimensions and weights are approximate and subject to change without notice and should not be used for construction purposes. Standard kVA Ratings 5000 7500 10000 12000 Liquid filled impulse ratings Nominal System Standard BIL, kV Voltage, kV 46 69 250 350 For more information contact your local GE Sales Representative or visit our website at www.prolecge.com Phone: Toll free 1 800-437-7653 (US & Canada) / +52 (81) 8030-2341 (Mexico) / Fax: +52 (81) 8030-2323 or 2325 SPSTTR-0409-01 The people and philosophy behind the products At Prolec GE, we’re proud of the dedication, integrity, skill and resourcefulness of our people. We carefully recruit, train, develop and promote only motivated, customer-focused professionals to power our operations. These outstanding individuals act as a team to help ensure our customers receive the products, service and support they need to thrive. Technology development Research and development is serious business at Prolec GE. Our Applied Technology Center boasts more than 80 engineers and specialists developing multi-generational product plans, design platforms, and continuous improvement processes. Their expertise and efforts make our customers’ operations more reliable, efficient and environmentally sound. We also draw technology expertise and ideas from our partners, including GE and its worldwide technology resources, our suppliers, customers, consultants, and university centers. Professionals at every level Our people are highly qualified professionals driven by a strong commitment to service, quality and performance. We emphasize the individual development of each member of our team through training and educational programs. We encourage vand reward employees who understand the value of building a career, instead of merely holding a job. Complete range of turnkey services You can trust Prolec GE with every aspect of your transformer solution for accountability and continuity advantages. Your project team coordinates and orchestrates your entire transformer package, including: • Rigging and Mobilizations • Transportation • Installation • Storage Preparation • Field Services • Maintenance • Training • Condition Assessment • Spare Parts Community Our strong values and behavior standards are part of our organizational culture. They guide our daily activities and influence our performance. From a ten-acre, on-site family activity center to integrated efforts that protect our environment, we make a concerted effort to improve the lives of our employees, our neighbors and our planet. Growing to meet your growing needs Worldwide energy needs are forecasted to skyrocket as we move through the 21st century. Prolec GE is uniquely situated to meet those needs. Our state-of-the-art facility continues to grow with multi-million-dollar expansions and ongoing equipment upgrades. Our strong supply-chain connections and worldwide resources provide us with a healthy stream of raw materials, shipping resources and business partners. So as your energy demands grow, you can continue to count on Prolec GE for the reliable solutions that power your individual needs. Headquarters & Service Sales Monterrey, N.L., Mexico Blvd. Carlos Salinas de Gortari Km. 9.25 Apodaca, N.L. 66600 Mexico Tel: +52 (81) 8030-2000 +52 (81) 8030-2400 Fax: +52 (81) 8030-2500 USA & Canada Contact your local GE sales representative or call 1-800-437-7653 or +52 (81) 8030-2341 24/7 Contact us: 1-800-4377-653 +52 (81) 8030-2360 Mexico City Paseo de la Reforma No. 222 - 8vo. Piso Col. Juarez Delegacion Cuauhtemoc, C.P. 06500 Mexico, D.F. Tel: +52 (55) 5329-2700 +52 (81) 8030-2400 01-800-377-6532 Fax: +52 (55) 5329-2727 Middle East General Electric International Operations Co., Inc. Dubai, United Arab Emirates Dubai Internet City, PO BOX 11549 Office G01, Building #18 Tel: +971 4 429 6101 Fax: +971 4 429 6133 ADDITIONAL CONTACT INFORMATION: See your local GE sales representative or visit our website www.prolecge.com or email [email protected] or [email protected] For information about our facilities in India: www.prolecge.in DTTR-0914-07