4DM Overview

Transcription

4DM Overview
4DM Integrated | 4DM Personal
A high level overview of 4DM functionality and the different ways
the software can be installed on your workstation.
What is 4DM?
Nuclear Cardiac Quantification, Review, & Reporting Software
4DM quantifies perfusion and function. In simplified terms, 4DM assigns values to parts of the heart based on how much blood
the heart muscle retains at rest vs stress – perfusion – and how well the heart expands and contracts at rest vs stress – function.
This quantification enables physicians to assess a patient’s cardiac health by reviewing patient images and 4DM values all in
a single, convenient and configurable application. Integrated reporting – within 4DM or with your PACS platform – further
streamlines the workflow.
4DM fits seamlessly into your current nuclear imaging workflow, receiving data from PET and SPECT cameras and exporting to
PACS and EMRs.
Patient Scan
4DM
PACS | EMR
4DM Quantification Results of Significance
»» Systolic Function: LV Volumes (indexed and unindexed), EF, Cardiac Output
»» Diastolic Function: Peak Filling and Emptying Rates
»» Regional Wall Thickening, Motion, and Time to Peak Contractility
»» Transient Ischemic Dilation (TID)
»» Myocardial Perfusion Quantification (Extent and Severity)
»» Semiquantitative Scoring (SSS, SRS, SDS, VS, SS)
»» Viability Quantification (delineate between ischemic, hibernating, and scar tissue)
»» Standard Uptake Value (SUV) for FDG PET imaging
»» Calcium quantification: Agatston score, volume, and lesions
»» Fully-Automated CFR quantification
Supported Patient Data
»» Nuclear Medicine: Static, Gated, Dynamic, Whole Body
»» SPECT Perfusion: Tomo, Recon Tomo, Gated Tomo, Gated Recon Tomo (SA, HLA, VLA, Transverse)
»» SPECT MUGA: Gated Tomo, Gated Recon Tomo (SA, HLA, VLA, Transverse)
»» PET: Static, Gated, Dynamic, Recon Tomo (SA, HLA, VLA, Transverse)
»» CT, SPECT-CT, PET-CT
»» Attenuation Correction Maps
»» 8- and 24-bit DICOM Static and Multi-Frame Screen Captures
www.inviasolutions.com
|
[email protected]
|
+1 734.205.1231 x214
Supported Cameras
4DM Licenses
Manufacturer | Model
SPECT
PET
Hybrid-CT
CFR
MiE | ECAM SCINTRON





—
—
—
—
—
—
—
—
—
—
—
—

—
—
Philips | Cardio 60; CardioMD; Vertex, Vertex Plus; Axis/Irix; Skylight;
Prism 1000/2000/3000; Forte; BrightView

—
—
—
Siemens | Multispect II/III; c.cam; e.cam; Evo, Evo Excel; Symbia S or “E”
GE Healthcare | Discovery LS (BGO)









—
—
—
—
—
—
—
—
—
—
—

—
—
—






—
—
—






—
—
—
—
—

—

—

—
—
—
—
—
—
—
—

—
—
GE Healthcare | Discovery ST (BGO), STE (BGO), RX (LYSO); 600 (BGO);
690 (LYSO); 710; Discovery IQ PET (BGO) 3R, 4R, 5R
—



Mediso | AnyScan PC
—
—
—
—








—
—
—

Digirad | Cardius XPO, Cardius XPO w/XACT AC
SPECT Cameras
GE Healthcare | Millenium; Infinia; Ventri; Discovery 630
GE Healthcare | Discovery 530c - Alcyone
Mediso | Nucline Series; AnyScan S
Spectrum Dynamics | DSPECT
SPECT-CT Cameras
Toshiba | GCA Series; t.cam
GE Healthcare | Discovery 570c - Alcyone
GE Healthcare | Discovery 670; Infinia Hawkeye; Optima 640
Mediso | AnyScan
Mediso | AnyScan SC
Philips | Precedence; BrightView CT
Siemens | Symbia T2, T6, T16; Intevo 2, 6, 16
PET Cameras
GE Healthcare | Advance NXi (BGO)
MiE | ECAT 47, HR+, ACCEL SCINTRON
Philips | C-PET; Allegro
Positron | Attrius
PET-CT Cameras
Siemens | ECAT Exact, HR/HR+, Accel
Philips | Gemini; Gemini GXL, TF; Ingenuity TF; Vereos PET/CT
Siemens | Biograph Duo/B16
Siemens | Biograph TruePoint 3R/4R, mCT 3R/4R, mCT Flow
4DM Integrated vs 4DM Personal
Same Application. Two Ways to Get It.
4DM is available integrated on the platforms of our many reseller partners, who range from large camera manufacturers, to
review workstation providers and integrated PACS developers.
Our resellers and INVIA also offer a stand-alone solution – 4DM Personal. 4DM Personal has the complete functionality of 4DM
Integrated and installs on Windows laptops or workstations.*
*For recommended system requirements, refer to the 4DM Personal Overview.
www.inviasolutions.com
|
[email protected]
|
+1 734.205.1231 x214
Product Features
Single Review Environment
»» Integrated Myocardial Perfusion with Function
»» Planar and SPECT Blood Pool Quantification
»» Multiple image formats (Splash, Three Short Axis)
»» 2D and 3D Polar Maps (Ungated, ED, ES Perfusion, Thickening, Motion, Contractility, Viability, SUV; Raw, Normalized,
Severity, Blackout, Defect Severity, Normalized Mean, Normalized Standard Deviation, and Thresholds)
»» Segmental Scoring Overlays
»» Auto-selected user-defined workflows and screens
»» Multi-monitor support
Quality Assurance & Quantification
»» Automatic quantification and cardiac reorientation
»» User selectable processing algorithms
»» Integrated quantification and review screens
»» Volumetric Co-registration of supported data
»» Tomo QA display (Cine Review, Sinogram, Linogram, Beat Histogram, Count Histogram, Gating Parameters)
Beyond SPECT & PET
»» CT Option (includes CT Review, Calcium Scoring, Vessel and Calcium Fusion, Reporting)
»» SPECT Reconstruction Option (Filtered Backprojection, Filtering, Reorientation)
»» Coronary Flow Reserve Option (Rb-82 and Ammonia PET Tracers)User Customizable Report Templates
»» Software-based fixed and floating licenses
Integrated Reporting
»» Simple interface for entering Patient Information and Stress / EKG results
»» Quantifications and images auto-filled from 4DM
»» Standard and user-customizable report templates
»» Auto-text generation based on quantifications
»» Real-time report preview
»» View EKG data in 4DM while entering findings into 4DM Reporting
»» Print and export reports in XML, RTF, PDF, HL7 v2, and HL7 v3 (CDA) directly from 4DM
»» Automatic report selection based on imaging protocol
Normals Databases
»» SPECT Protocol Databases: One and 2-day Tc99m, Dual Isotope (Tc99m and Tl-201), Tl-201 Stress/Rest/Redistribution
»» PET Protocol Databases: Rb-82 Distribution, FDG Viability (Statistically Generated), Ammonia (N-13)
»» Camera Specific SPECT Databases (C.CAM, C.Clear, Profile AC, Symbia AC, IQ•SPECT, cardiusx•act, 530C, D-SPECT, Astonish AC)
»» Iterative Reconstruction for SPECT (Astonish, Evolution, Flash3D, and nSPEED)
»» User-defined database generation and editing
Configurable
»» Change screen layouts or create custom screens
»» Create a custom workflow
»» Change colorbar preferences
»» Multi-location and multiple user support
Native Language Support
»» 4DM interface translation into: Chinese, Czech, Danish, Dutch, Finnish, French, German, Hungarian, Indonesian, Italian,
Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, and Turkish
»» 4DM Reporting interface translation into: French and German
www.inviasolutions.com
|
[email protected]
|
+1 734.205.1231 x214
One Application
Endless Possibilities
SPECT
PET
Gated Blood Pool (GBP)
Coronary Flow Reserve (CFR)
Hybrid-CT
4DM Reporting*
*Included with all 4DM Personal puchases.
May or may not be included with 4DM Integrated.
www.inviasolutions.com
|
[email protected]
|
+1 734.205.1231 x214
Our mission is to develop advanced imaging software for
medical professionals to optimize patient care.
PC_2016-01A
|