Data sheet Central domestic ventilation unit with heat recovery: ZL 400

Transcription

Data sheet Central domestic ventilation unit with heat recovery: ZL 400
Data sheet ZL 400
Central domestic ventilation unit with heat recovery
Domestic ventilation unit with heat recovery and bypass for controlled ventilation
and de-aeration of apartments and residential buildings with a central air distribution
system. Efficient constant volume flow regulated EC fans with three fan levels,
individually programmable air volumes for each level.Heat recovery from the
exhaust air via cross-counterflow heat exchanger. Ice protection with automatic
defrosting.Automatic summer bypass with adjustable switching temperature for
using cool night air in the summer by interrupting heat recovery.Integrated
self-diagnosis system with safety switch-off of the ventilation unit to prevent the
creation of vacuums in the building, to protect unheated living quarters from
overcooling, optionally via external smoke alarm.Illuminated LCD operator panel
with multilingual clear text menu navigation on the device. Integrated real-time clock
and weekly timer with up to 9 switching programs per day (individual) for 7
weekdays, for timed control of fan levels and automatic operation.The device can
optionally be controlled via a wired remote control, a wireless remote control or
according to need via automatic air volume regulation by using a CO2 and/or
humidity sensor to determine the exhaust air quality. Digital and analogue inputs
and outputs are integrated to enable external control.Filters for supply air, exhaust
air and bypass, filter class G4. Filter change indicator on the ventilation unit display
(can be set between 2 and 6 months). Filters can be changed without the use of
tools.The inner lining of the unit is made of EPP and complies with fire protection
class B2. Outer casing made of powder-coated sheet steel, white (RAL 9010),
inspection doors made of plastic, light grey.Air duct connections on the top of the
device, wall mounting possible using the wall bracket supplied. The condensate
connection is located on the bottom of the ventilation unit. The ventilation unit is
fully functional without any additional accessories.
Technical data
Dimplex Central domestic ventilation unit with heat recovery
Typ
ZL 400
Einsatzbereich
Luftvolumenstrom bei 120 Pa stat. Druckdiff. max.
Ventilatorstufen
Luftvolumenstrom (programmierbar)
Schalldruckpegel in 1 m Entfernung
Wirkungsgrad Wärmerückgewinnung max.
Bypass
Bypass switching temperature
Filterklasse Zuluft / Abluft
Spannungsversorgung
Max. power consumption
Leistungsaufnahme
Schutzart nach VDE
Anschluss Lüftungsleitungen
Condensate pipe connection
Dimensions (W x D x H)
Gewicht ohne Verpackung
m³/h
Stk
m³/h
dB (A)
%
A
W
mm
mm
kg
Living quarters approx. 120-300 m²
380
3
130 / 240 / 350
35 / 48 / 60
87
Yes
18-26 (Standard: 24)
G4 / G4
1/N/PE ~230 V, 50 Hz
2,60
200
IP 20
4x DN 160
Ø 20
750 x 469 x 725
35
*Air volume flow at a pressure loss within the pipe system of 120 Pa.
**Please note that additional space is required for pipe connections, operation and maintenance.
Glen Dimplex Deutschland GmbH
Dimplex Division
Am Goldenen Feld 18
95326 Kulmbach
Page 1/1
Subject to change and errors!
E-mail: [email protected]
Internet: www.dimplex.de
Internet: 21.05.2011
Phone: +49 (0)9221 709-201
Fax: +49 (0)9221 709-339