1 - City of Laredo
Transcription
1 - City of Laredo
ADDENDUM NO. 1 CITY OF LAREDO ADMINISTRATION BUILDING SOUTH LAREDO WASTEWATER TREATMENT PLANT 309 RIVER FRONT STREET ARCHITECTS PROJECT NO. 2015-08 To the general contractors, all sub-contractors, holders of plans and specifications and plan rooms, and all interested parties to the project above identified of the following revisions, clarifications to the plans and/or specifications of the above referred, some taking precedence over all previous declarations and notes made on plans/or specifications. Item No. 1 Refer to the Construction Drawings Set: Clarification: See attached Structural Drawings, S1, S2, S3. These documents were inadvertently left out of the construction document set. Item No. 2 Refer to the Construction Drawings Set, Sheet A2.0 Floor Plan, Sheet A6.0 Enlarge Plan, Lab 107: Omit note referring to lab hood by Owner. The laboratory hood is to be included in the project, purchased by the contractor and fully installed per manufacturer instructions for a complete operation as intended. Provide required infrastructure per shop drawings, submittals and MEP documents. Model No: 208-230V (4’ Protector XStream Laboratory Hood) Manufacturer: Labconco Corp. Contact: 1-800-821-5525 or 1-816-333-8811 Fax # 1-816-363-0130 www.labconco.com Item No. 3 Refer to the Construction Drawings Set: Clarification: The Civil Utilities Drawings per C-05 and Plumbing drawings per P-101 and P-201 North side vs east side services coordination utility connection issue, water & sewer connections are to be per Civil Drawings, Plumbing Drawings attached have been updated. Item No. 4 Refer to Civil Utilities Drawings per C-05 which indicates the location of the irrigation system main line to be used as the connection point. Note: the source of the line for the irrigation is effluent water and thus the irrigation system piping must comply with local and state governmental regulatory requirements which require 1) all underground piping and fittings to be PURPLE color Schedule 40 designed by a licensed irrigation designer and installer, 2) metal signs 12”x12” min. with pre-finished professional finish custom signs with text “Irrigation System – Effluent Water Use” mounted on 2” galv. chain link posts throughout site with poured concrete footing as Page 1 of 2 Addendum No. 1, City South Laredo WWTP Administration Building 8-4-16 directed by architect. Item No. 5 Refer to the Specification Booklet, Geo-technical Report: The architectural and civil drawings make reference to the thickness of the asphalt for the parking lot and driveway. Clarification: Per geo-technical report, Page 15, provide installation per recommended thickness of 1.5” and per detail instructions. Item No. 6 Refer to the Specification Booklet, Geo-technical Report: Refer to the geotechnical report dated June 15, 2016 for the recommendations for the preparation of the building pad, parking lot, driveway and underground utilities with additional information per City Standards. Item No. 7 Refer to the Specification Booklet, Section 01020 Allowances: In addition to the other allowances already called out for this section, include in the Base Bid an additional allowance reserved for Furniture and Equipment totaling $55,000.00 net to the Owner. The Owner will have to right to select a vendor(s) of their choosing to provide services, supplying and installing all items as required per Owner’s direction with vendor(s). The chosen vendor(s) will become a subcontractor(s) to the general contractor and the allowance must be covered by the performance / materials bond. A maximum of 5% OH&P may be added to this allowance and line item as this is a pass through line item for the general contractor. This Addendum No. 1 is being submitted on August 4, 2016 to the general contractors, all subcontractors, holders of plans and/or specifications, plan rooms and all interested parties to the project and acknowledgment of it is required in the Base Bid Form. Addendum No. 1 consists of 2 SAA, Inc. sheets, 3 Structural Drawings, S1, S2, and S3, and Plumbing Drawings, P-101, P-201 and P-401. SEPULVEDA ASSOCIATES ARCHTIECTS, INC. 1820 HOUSTON STREET LAREDO, TEXAS 78040 (956) 725-1985 FAX (956) 725-2396 [email protected] Page 2 of 2 REVISIONS: 2 10' - 5 1/2" FRAMING GENERAL NOTES A4.1 TOP & BOTTOM 2x4 METAL STUDS BRIDGING BETWEEN TRUSSES 60' - 0" 11' - 6 1/2" 1. REFER TO MECHANICAL DRAWINGS AC DRAWINGS FOR LOCATION AND SIZE OF REFRIGERANT PIPING AND DUCT WORK, MECHANICAL UNITS, WEIGHTS, & SUPPORTS. 10' - 0 1/2" 2. DIMENSIONS SHOWN ARE TO CMU FACE, COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL PLANS. 3. ROOF FRAMING PLANS, LAYOUTS AND DETAILS ARE PROVIDED TO ILLUSTRATE CONDITIONS OF CONSTRUCTION AND DO NOT NECESSARILY INDICATE SPECIFIC QUANTITIES OF MATERIALS OR COMPONENTS REQUIRED FOR CONSTRUCTION. ARCHITECT WILL HAVE THE OPTION ON SITE OF HAVING FRAMING SUBCONTRACTOR ADD ADDITIONAL MEMEBERS AS MAY BE NECESSARY IN THE OPINION OF THE ARCHITECT OR REQUIRED BY BUILDING INSPECTOR AS NECESSARY. PRE-ENGINEERED LIGHTWEIGHT ROOF TRUSSES AT 48" O.C. LN1 4. CONSTRUCTION BRACING SHALL BE PROVIDED BY THE CONTRACTOR TO MAINTAIN THE BUILDING PLUMB AND TRUE. THIS BRACING SHALL REMAIN UNTIL THE SPECIFIED SHEAR WALLS ARE TOTALLY INSTALLED. ARCHITECT WILL HAVE THE OPTION ON SITE OF HAVING FRAMING SUBCONTRACTOR ADD ADDITIONAL MEMEBERS AS MAY BE NECESSARY IN THE OPINION OF THE ARCHITECT OR REQUIRED BY BUILDING INSPECTOR AS NECESSARY. LN2 GALV. "SIMPSON" TIES OR EQUAL AT EVERY TRUSS FASTENED TO CMU/ WOODEN TOP PLATE LN1 3 A4.0 5. CONTRACTOR IS TO SUBMMIT LIGHTWEIGHT STEEL TRUSSES SHOP DRAWINGS TO ARCHITECT FOR REVIEW PRIOR TO FABRICATION 6. ALL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST APPLICABLE CODES AND STANDARDS. AISC, ASTM, IBC, ETC. 30' - 5 1/2" TYPICAL CMU LINTELS AT BEARING WALLS MAX. CLEAR SPAN BLOCK WIDTH (IN) LN1 3'-4" 8" LN2 6'-4" LN3 15'-0" MARK LN2 A4.0 GALV. "SIMPSON" TIES OR EQUAL AT EVERY TRUSS FASTENED TO CMU/ WOODEN TOP PLATE LN1 6' - 0 1/2" LN1 2 LN1 CMU BOND BEAM BELOW PRE-ENGINEERED LIGHTWEIGHT ROOF TRUSSES AT 48" O.C. FURRDOWN BELOW A5.0 TOP & BOTTOM 2x4 METAL STUDS BRIDGING BETWEEN TRUSSES LN1 LN1 LN1 GALV. "SIMPSON" TIES OR EQUAL AT EVERY TRUSS FASTENED TO CMU/ WOODEN TOP PLATE HORIZONTAL REINFORCING SHEAR STIRRUPS REMARKS 16" (2) #5 T&B #3 @ 8" O.C. TYP. AT ALL DOORS 8" 16" (2) #5 T&B #3 @ 8" O.C. 8" 24" (2) #6 EA #3 @ 16" O.C. SPECIAL INSPECTION NOTES: 1. LOCATE FIRST STIRRUP AT 1/2" OF THE REQUIRED SPACING AWAY FROM THE FACE OF THE WALL SUPPORT. (I.E. AT 8" O.C. SPACING, LOCATE 1ST STIRRUP NOT FURTHER THAN 4" FROM THE FACE OF THE WALL) 2. SPECIAL INSPECTION REQUIRED BY THE ARCHITECT OF RECORD AS NOTED ON SCHEDULE 3. SOLID GROUT FULL DEPTH OF LINTEL AND AT LEAST 8" PAST OPENING FOR LINTELS LESS THAN 8'-0" LONG AND PAST 16" OPENING FOR LINTEL LONGER THANT 8'-0" LN1 3" THK COMPOSITE ROOF DECK INSULATION BD. PER SPEC. STAGGERED LAYOUT 13' - 9 1/2" 15 ROOF TOP UNIT REF MEP LINTEL DEPTH (IN) LN1 LN1 6 LN3 A4.2 1 A4.1 LN3 0' - 5" 31' - 9 1/2" 17' - 6 1/2" 32' - 1 1/2" LAREDO, TEXAS ROOF TOP UNIT REF MEP CMU LINTEL SCHEDULE SOUTH LAREDO WASTEWATER TREATMENT PLANT TOP & BOTTOM 2x4 METAL STUDS BRIDGING BETWEEN TRUSSES 50' - 3 1/2" ROOF TOP UNIT REF MEP 7. ALL SHOP AND FIELD WELDING SHALL BE PERFORMED BY WELDERS QUALIFIED AS DESCRIBED IN "AMERICAN WELDING SOCIETY'S STANDARD QUALIFICATION PROCEDURE". ADMINISTRATION BUILDING LN1 CITY OF LAREDO LN3 0' - 5" 82' - 3 1/2" 1 SCHEMATIC FRAMING PLAN A4.0 1 FRAMING PLAN 3/16" = 1'-0" 17, June 2016 DATE CHECKED BY: RJS DRAWN LEP 2015-8 JOB. NO. SHEET NOTE: THE GENERAL CONTRACTOR SHALL VERIFY ALL EXTG. CONDITIONS, DIMENSIONS, AT JOB SITE FOR ALL ASPECTS OF PROPOSED SCOPE OF WORK AS NECESSARY TO ENSURE TOTAL FAMILIARIZATION OF CONDITIONS PRIOR TO BID DATE, REPORT ANY DEVIATIONS FROM PLANS TO ENSURE AN ADDENDUM IS ISSUED. NO EXTRAS WILL BE ALLOWED AFTER BIDDING PHASE. S-2 REVISIONS: 8" CMU BLOCK WALL BRICK VENEER 2" THK. RIGID INSULATION BD. w/ APPLIED MASTIC ALL BUTT JOINTS 16" HI CONTINUOUS MORTAR NETTING ELASTOMERIC SELF ADHESIVE SHEET DAMPROOFING VERTICAL REINFORCING #4'S AT 48" O.C. 5-1/2" THK. SLAB ON GRADE w/ #4'S BARST AT 12" O.C. EACH WAY AT MIDDEPTH OF SLAB OVER 10 MIL VISQUEEN MOISTURE BARRIER OVER APPROVED COMPACTED FILL 2' WIDE 4" THK. 3000 PSI CONCRETE MOWING STRIP w/ 6x6x6 WWF MATT & CONTROL JOINTS AT EVERY 5' CONCRETE MOWING STRIP 1" SLOPE LEVEL 1 0' - 0" 1" SLOPE 10 MIL MOISTURE BARRIER PER SPEC. TYP. REINF'G. TO BE (2) #6 BARS (T) & (B) WITH # 3 STIRRUPS AT 18" O.C. 10 MIL MOISTURE BARRIER PER SPEC. INTERIOR GRADE BEAM 3/4" = 1'-0" LEVEL 1 0' - 0" LEVEL 1 0' - 0" COMPACTED SELECT FILL PER SPEC. 10 MIL MOISTURE BARRIER PER SPEC. TYP. REINF'G. TO BE (2) #6 BARS (T) & (B) WITH # 3 STIRRUPS AT 18" O.C. 10 MIL MOISTURE BARRIER PER SPEC. FOUNDATION DETAILS 17, June 2016 PERIMETER GRADE BEAM AT ENTRANCE 3/4" = 1'-0" 1' - 0" 1' - 0" 2 PERIMETER GRADE BEAM AT ENTRANCE 3/4" = 1'-0" 1 PERIMETER GRADE BEAM 3/4" = 1'-0" CHECKED BY: RJS DRAWN LEP 2015-8 JOB. NO. SHEET NOTE: THE GENERAL CONTRACTOR SHALL VERIFY ALL EXTG. CONDITIONS, DIMENSIONS, AT JOB SITE FOR ALL ASPECTS OF PROPOSED SCOPE OF WORK AS NECESSARY TO ENSURE TOTAL FAMILIARIZATION OF CONDITIONS PRIOR TO BID DATE, REPORT ANY DEVIATIONS FROM PLANS TO ENSURE AN ADDENDUM IS ISSUED. NO EXTRAS WILL BE ALLOWED AFTER BIDDING PHASE. LAREDO, TEXAS COMPACTED SELECT FILL PER SPEC. DATE 1' - 0" 3 3' - 0" 3' - 0" TYP. REINF'G. TO BE (2) #6 BARS (T) & (B) WITH # 3 STIRRUPS AT 18" O.C. TYP. REINF'G. TO BE (2) #6 BARS (T) & (B) WITH # 3 STIRRUPS AT 18" O.C. 1' - 0" 4 3' - 0" 3' - 0" COMPACTED SELECT FILL PER SPEC. COMPACTED SELECT FILL PER SPEC. 5-1/2" THK. SLAB ON GRADE w/ #4'S BARST AT 12" O.C. EACH WAY AT MIDDEPTH OF SLAB OVER 10 MIL VISQUEEN MOISTURE BARRIER OVER APPROVED COMPACTED FILL 2' WIDE 4" THK. 3000 PSI CONCRETE MOWING STRIP w/ 6x6x6 WWF MATT & CONTROL JOINTS AT EVERY 5' 1' - 8" MIN. EMBED. 1' - 8" LEVEL 1 0' - 0" 1/2" EXPANSION JOINT SEALED VERTICAL REINFORCING #4'S AT 48" O.C. 1/2" EXPANSION JOINT SEALED 5-1/2" THK. SLAB ON GRADE w/ #4'S BARST AT 12" O.C. EACH WAY AT MIDDEPTH OF SLAB OVER 10 MIL VISQUEEN MOISTURE BARRIER OVER APPROVED COMPACTED FILL 1/2" EXPANSION JOINT SEALED 5-1/2" THK. SLAB ON GRADE w/ #4'S BARST AT 12" O.C. EACH WAY AT MIDDEPTH OF SLAB OVER 10 MIL VISQUEEN MOISTURE BARRIER OVER APPROVED COMPACTED FILL GRADE BEAM AT BRICK LUG 3/4" = 1'-0" MIN. EMBED. CMU WALL AND REINFORCING PER PLAN CITY OF LAREDO 5 10 MIL MOISTURE BARRIER PER SPEC. SOUTH LAREDO WASTEWATER TREATMENT PLANT TYP. REINF'G. TO BE (2) #6 BARS (T) & (B) WITH # 3 STIRRUPS AT 18" O.C. ADMINISTRATION BUILDING WEEP HOLES AT 24" O.C. 3' - 0" 0' - 1 1/2" 5" THK. SLAB ON GRADE w/ #4's BARS AT 12" O.C. EACH WAY AT MID-DEPTH OF SLAB OVER APPROVED COMPACTED FILL SD-1 REVISIONS: GENERAL NOTES FOR SITE PREPARATION 81' - 11 1/2" 2 1' - 0" 18' - 7 1/2" 1' - 0" 18' - 8 1/2" 3. SCARIFY THE SUBGRADE AT LEAST (6) SIX INCHES AND MOISTURE CONDITION BETWEEN OPTIMUM TO PLUS THREE (+3) PERCENTAGE POINTS OF THE OPTIMUM MOSTIRE CONTENT AND COMPACTED TO A MINIMUM OF 98% OF THE MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D698 (STD. PROCTOR). 1' - 0" 1' - 0" 18' - 8 1/2" 2. BUILDING AREAS TO SUPPORT SELECT FILL SHOULD BE STRIPPED OF ALL EXISTING VEGETATION AND TOPSOIL EXTENDING AT LEAST 5 FT BEYOND BUILDING PERIMETER. 60' - 0" A4.1 1' - 0" 1. REFER TO CIVIL AND ARCHITECTURAL PLANS FOR FINISH FLOOR ELEVATION. 3"x3"x1/8" TS. COLUMN w/ 1/4" STEEL PLATE GALV. GENERAL NOTES FOR REINFORCED CONCRETE 1. MATERIALS: A. SPECIFICATIONS: IN GENERAL, COMPLY WITH ACI 301-LATES EDITION "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS". B. STRUCTURAL CONCRETE ASTM C-150 TYPE I / II CEMENT. 1' - 0" 36' - 10 1/2" CONCRETE TYPE DESIGN STRENGTH FOUNDATION 3000 PSI 5-1/2" THICK SLAB ON GRADE WITH # 4 BARS AT 12" O.C. EACH WAY AT MID-DEPTH OF SLAB OVER 10 MIL VISQUEEN MOISTURE BARRIER OVER APPROVED COMPACTED FILL. F.D. F.D. TYP. SLAB CONTROL JOINTS AT 10 FT FROM PERIMETER EDGE MAX. NOT TO EXCEED 20 FT AT INTERIOR. INSTALL IN A PERIOD NOT TO EXCEED 12 HRS AFTER POUR 1-1/2" 0.5 0.6 2. FIELD MANUAL: PROVIDE AT LEAST ONE COPY OF ACI FIELD REFERENCE MANUAL, SP-15, IN THE FIELD OFFICE AT ALL TIMES. RECESS SLAB AT SHADED AREA 1-1/2" REFER TO ARCH. & MEP PLANS FOR FLOOR DRAIN LOCATIONS F.D. 5" MAXIMUM MAXIMUM W/C RATION AIR ENTR. NO AIR ENTR. AGGREGATE ALL MIXES SHALL HAVE A MINIMUM OF 5 SACKS OF CEMENT PER CUBIC YARD REGARDLESS OF STRENGTH OBTAINED. C. ALL DEFORMED REINFORCING BARS (ASTM A 615): FY=60,000 D. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A165-85. (SHEET FORM, NOT ROLLED) F.D. 1' - 0" F.D. MAXIMUM SLUMP F.D. 30' - 11 1/2" 13' - 3" F.D. 14' - 8 1/2" 3. CONTINGENCIES: A. PROVIDE SUPPORTS AS REQUIRED TO MAINTAIN ALIGNMENT OF SCHEDULED REINFORCING. SUCH SUPPORTS ARE TO BE REFLECTED IN THE BID. F.D. 51' - 1 1/2" 30' - 11 1/2" 5' - 1 1/2" 4. FOOTINGS: A. DOWELS IN FOOTINGS TO MATCH VERTICAL WALL REINFORCING. B. PROVIDE LEAN CONCRETE (CLASS IV) UNDER FOUNDATIONS FOR ACCIDENTAL OVEREXCAVATION, SOFT SPOTS AND TRENCHES. REFER TO CIVIL PLANS SD-1 14' - 7 1/2" 9' - 1" SD-1 14' - 7 1/2" 1 14' - 10" 1' - 0" 14' - 10" 1' - 0" 16' - 5 1/2" 1' - 0" 10' - 0 1/2" 1' - 0" 10' - 0 1/2" 1' - 0" 8' - 9" 7. CONCRETE COVER: UNLESS NOTED OTHERWISE, DETAIL REINFORCING TO PROVIDE CONCRETE COVER AS FOLLOWS: A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3 IN B. CONCRETE EXPOSED TO EARTH OR WEATHER: #5 BARS AND SMALLER 1-1/2 IN C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER SLABS, WALLS, AND #11 BARS & SMALLER 3/4 IN OTHERS: 1-1/2 IN 1' - 0" 1' - 0" 3' - 8" 1' - 0" 1' - 0" 6. CONSTRUCTION JOINTS: A. CONSTRUCTION JOINTS PERMITTED ONLY WHERE SHOWN OR AS APPROVED BY ARCHITECT. ALL CONSTRUCTION JOINTS ARE TO BE KEYED. KEYWAYS SHALL BE 1-1/2 INCHES DEEP x 1/3 MEMBER THICKNESS. CITY OF LAREDO 5' - 6 1/2" 0.00' 4 1' - 0" SD-1 9' - 1" 2 5' - 6 1/2" 1' - 0" 5. SPLICES: UNLESS NOTED OTHERWISE, LAP SPLICES AND EMBEDMENTS SHALL BE AS SHOWN ON TABLE BELOW. 1% SLOPE A4.2 7' - 0" 1 6 A4.1 0' - 2" 31' - 8" 18' - 5 1/2" 31' - 10" 0' - 2" 3 LAREDO, TEXAS 39' - 11 1/2" SOUTH LAREDO WASTEWATER TREATMENT PLANT 3"x3"x1/8" TS. COLUMN w/ 1/4" STEEL PLATE GALV. ADMINISTRATION BUILDING 9' - 11 1/2" 4. REFER TO GEOTECHNICAL ENGINEERING REPORT No. 40805 DATED JUNE 15, 2016 PREPARED BY HOWLAND ENGINEERING SCHEMATIC FOUNDATION PLAN SD-1 82' - 3 1/2" 17, June 2016 DATE 1 SCHEMATIC FOUNDATION PLAN 3/16" = 1'-0" CHECKED BY: RJS DRAWN LEP 2015-8 JOB. NO. SHEET NOTE: THE GENERAL CONTRACTOR SHALL VERIFY ALL EXTG. CONDITIONS, DIMENSIONS, AT JOB SITE FOR ALL ASPECTS OF PROPOSED SCOPE OF WORK AS NECESSARY TO ENSURE TOTAL FAMILIARIZATION OF CONDITIONS PRIOR TO BID DATE, REPORT ANY DEVIATIONS FROM PLANS TO ENSURE AN ADDENDUM IS ISSUED. NO EXTRAS WILL BE ALLOWED AFTER BIDDING PHASE. S-1 REVISIONS: ADDENDUM #1 OUTDOOR EMPLOYEE PORCH 116 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE BEFORE COMMENCING ANY PHASE OF THE WORK. ADJUSTMENTS FOR FIT AND COORDINATION SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. NOTIFY ENGINEER OF ANY CONFLICTS, DISCREPANCIES OR OMISSIONS PRIOR TO COMMENCEMENT OF THE CONTRACT WORK. 2" V REF. MENS 112 LV1 3" SS 3" SS 2" V VTR 3. CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES. 3"FD1 2 4" V VTR MECH ROOM 114 3" SS 4 2" V 3" SS 2" V UR1 WC2 4 SD1 SD1 SD1 SD1 5. PLUMBING CONTRACTOR TO FIELD COORDINATE WITH STRUCTURAL. ROUTE SANITARY LINES OUT AND AWAY FROM BEAMS WHERE POSSIBLE AND CROSS BEAMS PERPENDICULAR WITH SLEEVES AS REQUIRED. 3" WCO WC1 CUST 111 DWV KEYNOTES: FS1 MS1 1 PROVIDE 4"SS TO NEW BUILDING. REFER TO CIVIL SITE PLANS FOR CONTINUATION. 2 PROVIDE 1/2" TRAP PRIMER CONNECTION TO FLOOR DRAIN FROM WATER CLOSET. REFER TO PLUMBING DETAILS. 3 FLOOR DRAIN TO TIE INTO MOP SINK'S DRAIN ABOVE P-TRAP AS INDIRECT CONNECTION. REFER TO DETAIL SHEET. 4 SHOWER DRAIN TO TIE INTO ADJACENT SHOWER DRAIN ABOVE P-TRAP AS INDIRECT CONNECTION. 5 PROVIDE WALL CLEANOUT IN ACCESSIBLE LOCATION. 6 PROVIDE PLUMBING DWV ROUGH-IN FOR COONECTION TO FUME HOOD. FIELD COORDINATE EXACT HOOD PLUMBING REQUIREMENTS WITH OWNER/ARCHITECT. PROVIDE UNDER COUNTER ACID NEUTRALIZER ZURN MODEL" GREEN TURTLE pHIX" UNIT. 2" V 3 SD1 3" SS 3" SS WC2 WC1 SD1 4 HALL 108 2" V 4" SS DATA ROOM 105 2" V 3"FD1 HALL 101 EXIT 117 2 LV1 EWC1 2" V ABV 4" SS 3" SS EXIT 118 3" SS LAB 107 SUPER OFFICE 106 INCUBATOR REF. 6 3" SS LOBBY 100 SOLID MANAGMNT SUPVISOR 103 3" SS SK2 5 2" V OP SUPVISOR OFFICE 102 QC OFFICE 104 4" SS 3" SS 3" SS 2" V 3"WCO 2" V VTR DCO COVERED ENTRANCE PORCH 115 4" SS 1 1 OF TE XA TE TA S PLUMBING DWV PLAN 1 3/16" = 1'-0" S ES LIC E N S E D I G S IO NA L EN ER OF PR SEAN M. RODRIGUEZ 96478 PLUMBING DWV PLAN NE 2" V 8/4/2016 6/17/2016 DATE CHECKED BY: SMR DRAWN AEO JOB. NO. NOTE: THE GENERAL CONTRACTOR SHALL VERIFY ALL EXTG. CONDITIONS, DIMENSIONS, AT JOB SITE FOR ALL ASPECTS OF PROPOSED SCOPE OF WORK AS NECESSARY TO ENSURE TOTAL FAMILIARIZATION OF CONDITIONS PRIOR TO BID DATE, REPORT ANY DEVIATIONS FROM PLANS TO ENSURE AN ADDENDUM IS ISSUED. NO EXTRAS WILL BE ALLOWED AFTER BIDDING PHASE. 5656 S. STAPLES, SUITE 360, CORPUS CHRISTI, TX 78411 P - 361.852.2727 F - 361.852.2922 TEXAS ENGINEERING FIRM NO. 005318 16063 LAREDO, TEXAS WOMEN 110 SOUTH LAREDO WASTEWATER TREATMENT PLANT 3"FD1 EMPLOYEE WORKROOM 109 4. SEAL ALL WALL, ROOF, AND FLOOR PENETRATIONS WITH UL LISTED FIRE SEALANT. ADMINISTRATION BUILDING SK1 2. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, MECHANICAL & STRUCTURAL DRAWINGS AND SPECIFICATIONS FOR ANY ADDITIONAL REQUIREMENTS. CITY OF LAREDO 5 08/04/2016 GENERAL NOTES: 2" V 3"WCO - 16063 SHEET P-101 REVISIONS: ADDENDUM #1 - 08/04/2016 OUTDOOR EMPLOYEE PORCH 116 1/2" HW 1/2"CW&HW TO LAVS., TYP. 1/2" CW MECH ROOM 114 REF. SK1 4 LV1 LV1 3 3 MENS 112 3/4" CW 1/2" HW 1/2" HW 3/4" CW 1 1/4" CW 3/4" HW WC2 WC1 SHR2 GENERAL NOTES: SHR1 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE BEFORE COMMENCING ANY PHASE OF THE WORK. ADJUSTMENTS FOR FIT AND COORDINATION SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. NOTIFY ENGINEER OF ANY CONFLICTS, DISCREPANCIES OR OMISSIONS PRIOR TO COMMENCEMENT OF THE CONTRACT WORK. 1 1/4" CW 1 1/4" HW 2" CW UR1 EWH1 3/4"CW&HW TO MS1, TYP. 2. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, MECHANICAL & STRUCTURAL DRAWINGS AND SPECIFICATIONS FOR ANY ADDITIONAL REQUIREMENTS. MS1 CUST 111 3. CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES. 1/2"HW&CW TO SHOWERS, TYP. WC2 HALL 108 4. SEAL ALL WALL, ROOF, AND FLOOR PENETRATIONS WITH UL LISTED FIRE SEALANT. 5. PLUMBING CONTRACTOR TO FIELD COORDINATE WITH STRUCTURAL. ROUTE SANITARY LINES OUT AND AWAY FROM BEAMS WHERE POSSIBLE AND CROSS BEAMS PERPENDICULAR WITH SLEEVES AS REQUIRED. WC1 1 1/2" CW SHR1 1/2" CW 3/4" CW WATER KEYNOTES: 2" CW DATA ROOM 105 1/2" HW 2" CW EWC1 3 LV1 1/2" HW 3/4" CW LV1 3 WOMEN 110 1/2"CW&HW TO LAVS., TYP. EXIT 117 EXIT 118 HALL 101 1/2" CW 1/2" CW IMB SUPER OFFICE 106 INCUBATOR REF. 1/2" HW 4 5 1/2" CW LAB 107 LOBBY 100 OP SUPVISOR OFFICE 102 SOLID MANAGMNT SUPVISOR 103 1 PROVIDE 2"CW; REFER TO CIVIL SITE PLAN FOR CONTINUATION. 2 PROVIDE ELECTRIC WATER HEATER. INSTALL PER MANUFACTURER'S INSTALLATION INSTRUCTION. REFER TO PLUMBING FIXTURE SCHEDULE FOR SIZE AND TYPE. COORDINATE ELECTRICAL CONNECTION WITH ELECTRICAL CONTRACTOR. ROUTE T&P AND PAN DRAIN TO FLOOR SINK. 3 PROVIDE POINT-OF-USE THERMOSTATIC MIXING VALVE AT LAVATORY. SET VALVE TO DELIVER 105°F TEMPERED WATER. INSTALL PER MANUFACTURER'S INSTALLATION INSTRUCTION. 4 PROVIDE 1/2"CW LINE AND STOP AT 24"A.F.F. FOR REFRIGERATOR ICE MACHINE. 5 PROVIDE PLUMBING ROUGH-IN FOR COONECTION TO FUME HOOD. FIELD COORDINATE EXACT HOOD PLUMBING REQUIREMENTS WITH OWNER/ARCHITECT. QC OFFICE 104 1/2" HW 2" CW SK2 NFHB1 1 2" CW COVERED ENTRANCE PORCH 115 OF PR SEAN M. RODRIGUEZ 96478 ES LIC E N S E D I G S IO NA L EN ER PLUMBING WATER PLAN 3/16" = 1'-0" PLUMBING WATER PLAN NE 1 OF TE XA TE TA S S 1 8/4/2016 6/17/2016 DATE CHECKED BY: SMR DRAWN AEO JOB. NO. NOTE: THE GENERAL CONTRACTOR SHALL VERIFY ALL EXTG. CONDITIONS, DIMENSIONS, AT JOB SITE FOR ALL ASPECTS OF PROPOSED SCOPE OF WORK AS NECESSARY TO ENSURE TOTAL FAMILIARIZATION OF CONDITIONS PRIOR TO BID DATE, REPORT ANY DEVIATIONS FROM PLANS TO ENSURE AN ADDENDUM IS ISSUED. NO EXTRAS WILL BE ALLOWED AFTER BIDDING PHASE. 5656 S. STAPLES, SUITE 360, CORPUS CHRISTI, TX 78411 P - 361.852.2727 F - 361.852.2922 TEXAS ENGINEERING FIRM NO. 005318 16063 LAREDO, TEXAS EMPLOYEE WORKROOM 109 2 SOUTH LAREDO WASTEWATER TREATMENT PLANT 2" CW 1 1/4" HW 1 1/4" CW ADMINISTRATION BUILDING 1/2" CW CITY OF LAREDO NFHB1 16063 SHEET P-201 REVISIONS: ADDENDUM #1 3/4" CW - 08/04/2016 1/2" HW NFHB1 SK1 2" CW 3/4" HW 1/2" CW 3/4" CW 1/2" HW 2" CW 1/2" HW 1/2" HW 3/4" CW SA1 1/2" CW 3/4" CW 1/2" HW 1/2" CW 1/2" CW 3/4" CW 3/4" HW 2" CW SA1 2" CW LV1 1/2" CW 1/2" HW 3/4" CW 3/4" HW SA1 1/2" HW 3/4" CW 3/4" CW EWC1 SK2 1/2" HW LV1 1/2" CW MS1 UR1 WC2 1 1/4" CW 1 1/4" HW SA1 1/2" HW 1/2" CW 1/2" HW 1/2" CW 3/4" CW 1 1/4" HW LV1 NFHB1 LV1 1/2" CW 1/2" HW 1 1/4" CW WC2 1 1/2" CW WC1 1 1/2" CW TO EWH1 2" V VTR 2" CW 1/2" CW 1/2" HW SHR1 1/2" HW SHR2 1/2" CW SHR1 1 2" V WATER RISER DIAGRAM 2 3" SS 2" V VTR 2" V 4" V VTR CITY OF LAREDO 2" V 2" V 2" V 2" V 2" V 2" V 3" SS 2" V 2" V 2" V 2" V 2" V 4"LV1 V 2" V LV1 2" V SK2 3" SS 2" V UR1 2" V ABV EWC1 SHR2 WC2 2" V WC2 WC1 4" SS 3" SS LV1 2" SS 3"FD1 2" V 2" SS SD1 SD1 SHR1 2" V SD1 4" SS 4" SS BEL 3" SS SHR1 3"FD1 WC1 LV1 2" V 3" SS 2" V 2" V MS1 3"FD1 2" V 2" V SD1 SD1 SD1 3" WCO 3" SS FS1 3" SS 3" SS 3" SS 3" SS 4" SS S PLUMBING RISER DIAGRAMS OF TE XA TE TA S 4" SS DCO 4" SS DWV RISER DIAGRAM NE 8/4/2016 4" SS 1 ER OF PR SEAN M. RODRIGUEZ 96478 ES LIC E N S E D I G S IO NA L EN 6/17/2016 DATE CHECKED BY: SMR DRAWN AEO 1 JOB. NO. NOTE: THE GENERAL CONTRACTOR SHALL VERIFY ALL EXTG. CONDITIONS, DIMENSIONS, AT JOB SITE FOR ALL ASPECTS OF PROPOSED SCOPE OF WORK AS NECESSARY TO ENSURE TOTAL FAMILIARIZATION OF CONDITIONS PRIOR TO BID DATE, REPORT ANY DEVIATIONS FROM PLANS TO ENSURE AN ADDENDUM IS ISSUED. NO EXTRAS WILL BE ALLOWED AFTER BIDDING PHASE. 5656 S. STAPLES, SUITE 360, CORPUS CHRISTI, TX 78411 P - 361.852.2727 F - 361.852.2922 TEXAS ENGINEERING FIRM NO. 005318 16063 LAREDO, TEXAS 2" SS SOUTH LAREDO WASTEWATER TREATMENT PLANT ADMINISTRATION BUILDING SK1 16063 SHEET P-401