4933 Bid Set.dwf - SRC Services, Inc.
Transcription
4933 Bid Set.dwf - SRC Services, Inc.
1 2 3 4 5 6 7 K 8 9 10 11 12 13 14 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 REMODEL 2.0 PREMIUM CONSULTANT PROJECT150066 # Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect J SEAL FOR RIVERCHASE GALLERIA H STORE #4933 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A G IF REQ'D, STOCKROOM SHELVING TO BE UNDER SEPARATE PERMIT, SUBMITTED BY SHELVING MANUFACTURER. DRAWING INDEX F DRAWING DESCRIPTION SUNGLASS HUT SPACE:#236A LEVEL 2 OF 2 E G-001 COVER SHEET G-002 RESPONSIBILITY & DOOR SCHEDULE A-101 DEMOLITION / LEASE PLAN A-102 FLOOR PLAN A-103 FINISH / FIXTURE PLAN A-104 REFLECTED CEILING PLAN A-201 ELEVATIONS A-301 NOT USED D USER: PDICKERSON STOREFRONT PLAN & ELEVATION A-501 STOREFRONT DETAILS A-502 GENERAL DETAILS A-503 NOT USED A-504 NOT USED A-505 NOT USED A-701 ARCHITECTURAL SPECIFICATIONS A-702 ARCHITECTURAL SPECIFICATIONS PROJECT CONTACTS C Project Manager B GENERAL GROWTH PROPERTIES, INC. 110 NORTH WACKLER DRIVE CHICAGO,IL 60606 Contact:PHYLLIS WETHERALL Phone: 312-960-5873 Store Planner SYMBOLS LEGEND Architect LUXOTTICA 4000 LUXOTTICA PLACE MASON, OH 45040 CONTACT: SHEILA HULL PHONE: 513-765-3847 E-MAIL: [email protected] SHREMSHOCK ARCHITECTS, INC. 7400 W. CAMPUS RD. SUITE 150 NEW ALBANY, OH 43054 CONTACT: JASON RICHARDSON PHONE: 614-545-4550 E-MAIL: [email protected] 2009 IBC 2009 IPC 2008 NEC 2009 IMC 2009 IECC ICC.ANSI A117.1 USE GROUP: CONSTRUCTION TYPE: SEISMIC CATEGORY: M-MERCANTILE IIB, FULLY SPRINKLERED B SALES AREA: NON-SALES AREA: TOTAL: 601/30 = 21 57/30 = 2 23 EXITS REQUIRED: EXITS PROVIDED: 1 1 WATER CLOSETS: LAVATORIES: Landlord LUXOTTICA 4000 LUXOTTICA PLACE MASON, OH 45040 CONTACT: SCOTT YOUNG PHONE: 940-445-3122 E-MAIL: [email protected] BUILDING CODE: PLUMBING CODE: ELECTRICAL CODE: MECHANICAL CODE: ENERGY CODE: ACCESSIBILITY: TENNANT SEPARATION WALLS:1 HR SALES/NON-SALES WALLS: 0 HR CEILING: 0 HR COLUMNS: 0 HR NORTH PLOTTED: 7/8/2015 - 4:45 PM P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\G-001_04933.dwg LAYOUT: G-001 A-401 BUILDING CODE THIS PROJECT IS A TENANT BUILD OUT OF A NEW MERCANTILE SPACE IN AN EXISTING INTERIOR CENTER. A1 SECTION ID SHEET NUMBER A-301 A1 ROOM NAME DETAIL ID SHEET NUMBER A-401 101 AT LANDLORD NOTES REV. 1 MALL KEY PLAN - DRINKING FOUNTAIN: PUBLIC ACCESS: SERVICE SINK: E-101 POWER PLAN E-102 LIGHTING PLAN & LIGHTING LEGEND E-501 ELECTRICAL DETAILS, SYMBOLS & ABBREVIATIONS E-601 ELECTRICAL SINGLE LINE DIAGRAM & PANEL SCHEDULES E-701 ELECTRICAL SPECIFICATIONS E-702 ELECTRICAL SPECIFICATIONS - 1 1 NOT REQUIRED NOT REQUIRED NOT REQUIRED RIVERCHASE GALLERIA 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM NAME NUMBER SGH STORE #:4933 AREA CALCULATIONS Purchasing Coordinator MEP Consultant LUXOTTICA 4000 LUXOTTICA PLACE MASON, OH 45040 CONTACT: DAWN SPARKS PHONE: 513-765-3947 E-MAIL: [email protected] 1 A1 SHREMSHOCK ENGINEERING, INC. 7400 W. CAMPUS RD. SUITE 150 NEW ALBANY, OH 43054 CONTACT: JEROMY PERRY PHONE: 614-545-4550 E-MAIL: [email protected] 2 3 ELEVATION ID SHEET NUMBER A-201 4 LOCATION ELEVATION STOREFRONT FRONTAGE: SHEET NUMBER A-201 ELEVATION ID A7 FLOOR 0'-0" DRAWN BY:PWD REVIEWED BY:RJH/JRM A1 A RIVERCHASE GALLERIA SIGNAGE AND SPRINKLER PLAN TO BE SUBMITTED UNDER SEPARATE COVER RETAIL AREA STOCK AREA: NORTH TOTAL: LEASED TOTAL 1 1 5 6 AUTHORIZED FOR: 34 LF 601 SF 0 SF COVER SHEET 658 SF 766 SF MATERIAL NUMBER 7 8 G-001 9 10 11 12 13 14 4 5 6 AMERICANS WITH DISABILITIES ACT ACCESSIBILITIES GUIDELINES ABOVE FINISH FLOOR CENTERLINE CEILING CERAMIC TILE COLUMN CONCRETE CONTINUOUS DIAMETER DIMENSION DETAIL DRAWINGS ELECTRICAL CONTRACTOR EXISTING EXPOSED EQUAL FIXTURE CONTRACTOR GYPSUM BOARD GENERAL CONTRACTOR A.F.F. CL. CLG. CT. COL. CONC. CONT. DIA. DIM. DTL. DWGS. E.C. EX. OR (E) EXP. EQ. F.C. G.B. G.C. J G.A.T. M.C. N.I.C. O.C. OPP. O/ P.C. REQ. R. SCH. SIM. TYP. U.N.O. V.I.F. VERT. W.C. WD. W.R. DOOR INFORMATION MARK H T = TENANT/OWNER G = GENERAL CONTRACTOR L = LANDLORD E = EXISTING GYPSUM CEILING TILE MECHANICAL CONTRACTOR NOT IN CONTRACT ON CENTER OPPOSITE OVER PLUMBING CONTRACTOR REQUIRED RADIUS SCHEDULED SIMILAR TYPICAL UNLESS NOTED OTHERWISE VERIFY IN FIELD VERTICAL WATER CLOSET WOOD WATER RESISTANT ITEM FRAME INFORMATION LOCATION NOMINAL SIZE A1 (E) ENTRY PR. 3'-0"W. x 8'-10"H. x 1/2" ALUMINUM / GLASS PREFIN. ALUMINUM PREFIN. - A B1 SALES / NON-SALES 3'-0"W. x 7'-0"H. x 1 3/4" HOLLOW METAL P-3 HOLLOW METAL P-3 - B (E) TOILET ROOM 3'-0"W. x 6'-8"H. x 1 3/4" HOLLOW METAL P-4 HOLLOW METAL P-4 - C (E) SERVICE 3'-0"W. x 7'-0"H. x 1 3/4" C1 D1 MATERIAL HOLLOW METAL FINISH P-4 MATERIAL HOLLOW METAL FINISH P-4 FIRE RATING EXIST. FURNISHED BY A.D.A.A.G. K 7 - EXISTING TO REMAIN. EXISTING TO REMAIN LOCKSET: BOTTOM RAIL CYLINDER LOCK C - UNFI INISHED DOOR AND FRAME SUPPLIED, INSTALLED AND FINISHED BY G.C. (U.N.O.) PRIVACY SET: CORBIN RUSSWIN MODEL #CL3620 NZD (LEVER STYLE); FINISH #BHMA 626 OR SCHLAGE EQUAL; PUSH BUTTON ON INSIDE AND KEY ON OUTSIDE LOCK CORES: BEST LOCK CORP.; 9K SERIES DOOR CLOSER: CORBIN RUSSWIN DC4610 SERIES PARALLEL ARM WITH HOLD OPEN. HINGES: BOMMER 1 1/2 PAIR PER LEAF, 4-1/2" x 4-1/2", NO. BB5004N STANDARD WEIGHT, AVERAGE FREQUENCY, FULL MORTISE, BALL BEARING HINGE, FINISH STAINLESS STEEL KICKPLATE: STANLEY DOOR SYSTEM; FULL WIDTH x 10"H x 1/8" STAINLESS STEEL INSTALLED 1" FROM BOTTOM OF DOOR FLOOR MOUNTED STOP: IVES MODEL #FS13US26 CAST BRASS, CHROME PLATED (OR EQUAL) SILENCERS: G.C. TO SELECT F USER: JYOUNG D SE D 3'-0" A1 1. A B1 7'-0" 6'-8" 7'-0" 8'-10" B 3'-0" 3'-0" NO TU 3'-0" SE D C NO TU PLOTTED: 7/9/2015 - 10:43 AM P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\G-002_04933.dwg LAYOUT: G-002 E 3'-0" C1 D1 VERIFYING EXISTING DOOR HARDWARE TYPE AT LOCATIONS WHERE EXISTING EXTERIOR/ENTRANCE DOORS ARE TO REMAIN. ANY NON-GENERIC/BRANDED DOOR HARDWARE TO BE IDENTIFIED AND REPLACEMENT MUST BE COORDINATED WITH LUXOTTICA PROJECT MANAGER. A1 SCALE: 10 11 HDWR. D NOTE: VERIFY ALL ITEMS IN THIS SCHEDULE FOR ACCURACY PRIOR TO BEGINNING CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE PROJECT MANAGER IMMEDIATELY. FURN. INST. REMARKS T PERMIT APPLIED FOR BY TENANT / OBTAINED AND PAID FOR BY CONTRACTOR TEMPORARY BARRICADES (WITH GRAPHIC) T T TEMPORARY CONSTRUCTION WINDOW VINYL T T DIVISION 03 - CONCRETE FURN. INST. REMARKS CONCRETE SLAB E G.C. TO VERIFY AS REQUIRED G.C. TO COORDINATE WITH LANDLORD BARRICADE VENDOR FURN. INST. STRUCTURAL STEEL E TENANT SEPARARTION WALL E DIVISION 08 - OPENINGS FURN. INST. STOREFRONT SYSTEM E/T STOREFRONT DOORS AND HARDWARE E/G E REMARKS 14 THE CONTRACTOR SHALL HAVE EVIDENCE OF CURRENT WORKER'S COMPENSATION INSURANCE ON FILE IN COMPLIANCE WITH LOCAL CODES. 2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL SHOW EVIDENCE OF ALL INSURANCE REQUIREMENTS. 3. THE CONTRACTOR SHALL BE FAMILIAR WILL ALL LANDLORD REQUIREMENTS AND SHALL BE RESPONSIBLE FOR COMPLIANCE WITH REQUIREMENTS. THE CONTRACTOR SHALL INVESTIGATE LOCAL CODES AND PROCEDURES AND SHALL COMPLY WITH REQUIREMENTS. 4. SIGN CONTRACTOR TO OBTAIN SIGN PERMITS FROM BUILDING DEPARTMENT AS APPLICABLE. 5. CONTRACTOR SHALL CONTACT LANDLORD REPRESENTATIVE BEFORE CONSTRUCTION COMMENCES. 6. ALL CONDUIT, EQUIPMENT AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST SAFETY RULES AND REGULATION OF ALL AUTHORITIES AND AGENCIES HAVING JURISDICTION. 7. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE DURATION OF THE WORK ALL EXITS, EXIT LIGHTING, FIRE PROTECTION DEVICES AND ALARMS IN CONFORMANCE WITH ALL APPLICABLE CODES AND ORDINANCES. 8. PROVIDE ADDITIONAL EXIT SIGNS AND FIRE EXTINGUISHERS IN TYPE , NUMBER, AND LOCATION AS DIRECTION BY THE AUTHORITIES HAVING JURISDICTION. SEE PLANS 9. DURING ALL PHASES OF WORK DO NOT DISTURB THE DELIVERIES AND FUNCTIONS OF ADJACENT AND NEIGHBORING TENANTS. REMARKS 10. EACH CONTRACTOR SHALL LEAVE THE SITE IN A NEAT, CLEAN AND ORDERLY CONDITION UPON THE COMPLETION OF THEIR WORK ON A DAILY BASIS. AREA OF WORK TO BE DUSTED, SWEPT AND MOPPED TO SAME CONDITION AS START OF WORK. ALL WASTE OR EXCESS MATERIALS SHALL BE REMOVED FROM THE SITE PROMPTLY. THE G.C. SHALL BE RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL TRASH, INCLUDING TRASH GENERATED FROM OWNER FURNISHED ITEMS AND BY OWNERS CONTRACTORS FOR THE DURATION OF THE PROJECT. COORDINATE LOCKSMITH IF NOT COMPATIBLE WITH TENANT KEY SYSTEM 11. ALL EXISTING WORK NOT IN THIS SCOPE OF WORK SHALL BE MAINTAINED IN ITS ORIGINAL CONDITION, U.N.O. E/T T/G 13 1. REMARKS BUILDING PERMIT DIVISION 05 - METALS 12 GENERAL NOTES DIVISION 01 - GENERAL DOOR LOCK CORES AND KEYS T DIVISION 09 - FINISHES FURN. INST. TENANT SEPARATION PARTITIONS (GYPSUM WALLBOARD) E E/G G.C. TO VERIFY, PATCH/REPAIR AS REQUIRED STOREFRONT BULKHEAD E E/G G.C. TO VERIFY, PATCH/REPAIR AS REQUIRED CEILING E E/G 14. G.C. SHALL BE RESPONSIBLE FOR COORDINATION WITH OWNERS REPRESENTATIVE TO PROVIDE A TIMELY ARRIVAL OF ALL MATERIALS, EQUIPMENT AND OTHER SUCH ITEMS TO BE UTILIZED ON THIS PROJECT. G.C. SHALL NOTIFY OWNER'S REPRESENTATIVE IN WRITING WITHIN 5 DAYS OF DATE OF APPROVED WORK AUTHORIZATION OF THOSE ITEMS THAT MAY BY READILY AVAILABLE. IF NOTIFICATION IS NOT PROVIDED TO THE OWNER'S REPRESENTATIVE, THE CONTRACT ACCEPTS RESPONSIBILITY FOR THE PROPER ORDERING AND FOLLOW-UP OF SPECIFIED ITEMS AND WILL PURSUE WHATEVER MEANS NECESSARY AT NO ADDITIONAL COST TO OWNER. 1/8" GROUT JOINTS TYP. 15. CONTRACTOR TO ENSURE AVAILABILITY OF ALL SPECIFIED ITEMS SO AS NOT TO CREATE A HARDSHIP TO THE OWNER AND NOT DELAY PROGRESS OF THE WORK. NO EXTENSION OF TIME SHALL BE PERMITTED. REMARKS 2 3 4 CONSULTANT PROJECT # 150066 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect SEAL 13. WHEN CONTRACTOR ACCEPTS DELIVERY OF ALL ITEMS NOTED ON PLANS WHETHER IN CONTRACT OR NOT IN CONTRACT, THE G.C. SHALL BE RESPONSIBLE FOR LOSS AND/OR DAMAGE TO THESE ITEMS. T G GROUT G G MALL FLOORING E/L L/G ALUMINUM BASE MOULDING (HPL-06) T G DIVISION 10 - SPECIALTIES FURN. INST. SIGNAGE E/T AWNING - DIVISION 12 - FURNISHINGS FURN. INST. REMARKS MILLWORK FLOOR FIXTURES T T G.C. TO COORDINATE WITH VENDOR U-RAIL GRAPHIC HANGING SYSTEM (TBD) T G LOOSE FIXTURES/PROPS T T G.C. TO COORDINATE WITH VENDOR, G.C. TO UNBOX, UNWRAP AND STORE IN B.O.H. MISCELLANEOUS EQUIPMENT T G SEE EQUIPMENT SCHEDULE GRAPHICS GRID T G 16. CONTRACTOR SHALL BE RESPONSIBLE TO RECEIVE, INVENTORY, STORE, AND SECURE ANY OWNER FURNISHED ITEMS SUPPLIES AND DELIVERED TO THE JOBSITE, OR OTHER AGREED UPON LOCATION, AND FORWARD THE RECEIVING DOCUMENTS TO THE OWNER. REMARKS 17. NO MATERIAL SUBSTITUTIONS WILL BE ALLOWED UNLESS NOTED OTHERWISE OR SUBMITTED IN WRITING TO AND APPROVED BY THE OWNER'S REPRESENTATIVE. T G.C. TO COORDINATE WITH VENDOR 18. ANY WOOD CONSTRUCTION SHALL BE FIRE RETARDANT TREATED, U.N.O. - N/A 19. G.C. SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTOR'S BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OR RESPONSIBILITY IN PERFORMANCE OF WORK. 20. ALL CONTRACTORS, SUBCONTRACTORS, VENDORS AND MATERIAL SUPPLIES SHALL BE RESPONSIBLE FOR REVIEWING THE COMPLETE SET OF DOCUMENTS AS SHOWN IN THE SHEET INDEX. FAILURE TO REVIEW CONSTRUCTION DOCUMENTS WILL NOT RELIEVE ANY CONTRACTORS, SUBCONTRACTORS, VENDORS OR MATERIAL SUPPLIES FOR PERFORMING WORK OR PROVIDING MATERIALS REQUIRED FOR THE COMPLETION OF THIS PROJECT AS DEFINED WITHIN THE DOCUMENTS AT TIME OF BID. TOILET ACCESSORIES G DIVISION 21 - FIRE SUPPRESSION FURN. INST. SPRINKLER SYSTEM MODIFICATIONS E E FIRE SPRINKLER MAIN E E DIVISION 22 - PLUMBING FURN. INST. WATER AND SEWER STUB E E 24. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DRAWINGS. WATER METER E E GAS METER E E 25. ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER OTHER DRAWINGS FOR LAYOUT DIMENSIONS AND NUMBER OF ITEMS PROVIDED. UPON DISCOVERY OF DISCREPANCIES BETWEEN ARCHITECTURAL DRAWINGS AND ENGINEERING DRAWINGS, OWNER SHALL BE IMMEDIATELY NOTIFIED IN WRITING. PLUMBING FIXTURES E E DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING FURN. INST. G AIR CURTAIN E E EXHAUST FANS AND VENTING E E HVAC UNIT E E HVAC CONTROLS E E 21. G.C. SHALL COORDINATE WORK PERFORMED BY OTHER CONTRACTORS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE OWNER'S ATTENTION (VERBALLY AND DOCUMENTED IN WRITING) BEFORE PROCEEDING WITH WORK. REMARKS 22. SHOULD A CONFLICT EXIST BETWEEN THE CONSTRUCTION DOCUMENTS AND/OR THE SPECIFICATIONS, THE OWNER'S REPRESENTATIVE SHALL BE INFORMED (VERBALLY AND DOCUMENTED IN WRITING) OF THIS DISCREPANCY IMMEDIATELY, AT WHICH TIME OWNER'S REPRESENTATIVE SHALL PROVIDE DIRECTION ON HOW TO PROCEED. 23. INSPECT SITE AND VERIFY FIELD DIMENSIONS BEFORE COMMENCING WITH CONSTRUCTION. NOTIFY OWNER'S REPRESENTATIVE AND LANDLORD IMMEDIATELY IF THERE ARE ANY DISCREPANCIES. REMARKS 26. IF ANY ERRORS OR OMISSIONS APPEAR IN THE CONTRACT DOCUMENTS, CONTRACTOR SHALL NOTIFY OWNER IN WRITING OF SUCH ERRORS OR OMISSIONS. 27. DIMENSIONS SHOWN ON PLANS ARE TO FACE OF CMU, CONCRETE COLUMNS OR GRID LINES AND FACE OF GYPSUM BOARD UNLESS NOTED OTHERWISE. REMARKS 28. THE CONTRACTOR SHALL REVIEW ALL CONSTRUCTION DOCUMENTS, VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AND CONFIRM WORK IS BUILDABLE AS SHOWN. ANY CONFLICTS OR OMISSIONS, ETC. SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT FOR CLARIFICATION PRIOR TO PERFORMANCE OF ANY WORK IN QUESTION. 29. COLUMN CENTER LINE (OR GRID LINES) ARE SHOWN FOR DIMENSIONS. VERIFY EXACT LOCATION IN FIELD. ENERGY MANAGEMENT SYSTEM (EMS) - - HVAC DISTRIBUTION DUCTWORK, DIFFUSERS E E CURBS & SUPPORTS FOR CONDENSING UNITS - - N/A SMOKE EVACUATION SYSTEM & CONTROLS E E - DUCT SMOKE DETECTORS - - N/A DIVISION 26 - ELECTRICAL FURN. INST. ELECTRICAL SERVICE, CONDUIT, WIRING E/G E/G ELECTRIC METER, SEPARATE E/G E/G ELECTRICAL PANELS E/G E/G TRACK CURRENT LIMITING PANEL - - EMERGENCY LIGHTING E/T E/G EXIT SIGNS E/T E/G FIRE ALARM SYSTEM - - LIGHT FIXTURES E/T E/G LAMPS E/T E/G SOUND SYSTEM & SPEAKERS T T COORDINATE WITH VENDOR TENANT TELEPHONE EQUIPMENT T T COORDINATE WITH VENDOR TELEPHONE CONDUIT TO SPACE L/E TELEPHONE WIRING TO SPACE L/E SECURITY - FACILITY/HARDWARE & WIRING/VECTOR (ALARMS) T T COORDINATE WITH VENDOR SECURITY - PRODUCT/HARDWARE & WIRING/- A1 (CAMERAS) T T COORDINATE WITH VENDOR TRAFFIC COUNTER T T COORDINATE WITH VENDOR N/A 30. OWNER'S REPRESENTATIVE AND TENANT ARE THE SAME FOR PURPOSES OF THESE DRAWINGS. 31. ALL OPENINGS, FLASHING, COUNTER FLASHING, AND EXPANSION JOINTS SHALL BE WATERTIGHT IN EXTERIOR STORES. 32. ALL OPEN JOINTS, PENETRATIONS AND OTHER OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED OR WEATHER-STRIPPED TO LIMIT AIR LEAKAGE IN EXTERIOR STORES. 33. ALL SAW CUTTING AND CORING LOCATIONS SHALL BE REVIEWED AND COORDINATED WITH THE LANDLORD PRIOR TO CUTTING/ CORING. REMARKS 34. G.C. IS RESPONSIBLE FOR MAINTAINING REQUIRED FIRE RATINGS AND FIRE PROOFING IN ALL INSTANCES. 35. GC TO COVER THE STOREFRONT WINDOWS AND DOORS WITH KRAFT PAPER FROM THE TIME THE BARRICADE IS REMOVED UNTIL THE STORE OPENS. 36. GC TO SCHEDULE A PRE-TURNOVER CLEANING FOR WEDNESDAY MORNING AND A FINAL DETAIL CLEANING TUESDAY MORNING AT 9:00 AM PRIOR TO OPENING. 37. TIMECLOCK TO BE SET TO "ON" 30 MINUTES PRIOR TO MALL OPENING AND 30 MINUTES AFTER MALL CLOSE. 38. INSTRUCTIONS FOR MODIFYING THE TIMECLOCK OPERATION TO BE LEFT WITH THE STORE AND DETAILED MANAGEMENT AT TURNOVER. 39. GC IS RESPONSIBLE TO ACCEPT DELIVERY OF ALL PROPS - UN-BOX, SORT AND COUNT. THE SUPERINTENDENT SHOULD GIVE A CHECK-IN SHEET NOTING ALL DISCREPANCIES TO THE PROJECT MANAGER UPON ARRIVAL FOR THE PUNCHLIST. 40. ALL CARDBOARD SHOULD BE REMOVED FROM THE SITE PRIOR TO TURNOVER, HOWEVER, THE PROPS SHOULD BE LEFT IN THE PLASTIC TO PROTECT FROM DAMAGE/DUST. 5 6 7 8 RIVERCHASE GALLERIA 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM SGH STORE #: 4933 DRAWN BY: PWD/CBV/XXX REVIEWED BY: RJH AUTHORIZED FOR: RESPONSIBILITY & DOOR SCHEDULE G-002 DOOR SCHEDULE 1 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 12. PROTECT WORK FROM DAMAGE RESULTING FROM THIS WORK. CERAMIC TILE FLOORING A 9 STOREFRONT TILE G.C. TO REPLACE ANY MISSING OR DAMAGED HARDWARE G 8 RESPONSIBILITY SCHEDULE AT 3 RIVERCHASE GALLERIA 2 ABBREVIATIONS INSTALLED BY 1 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 GENERAL NOTES 1. TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE PUBLIC AND/OR WORKERS ON THE JOB AND TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON ON, ABOUT, OR ADJACENT TO THE PREMISES. COMPLY WITH ALL LAWS, ORDINANCES, CODES, RULES AND REGULATIONS RELATIVE TO SAFETY AND THE PREVENTION OF ACCIDENTS. 2. THIS DEMOLITION PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET OF WORKING DRAWINGS. DO NOT REMOVE OR DEMOLISH ANYTHING WITHOUT VERIFYING AND COORDINATING WITH ALL GENERAL TRADES AS TO HOW THEY RELATE TO THE OVERALL PROJECT. 3. ALL CONTRACTORS SHALL BE RESPONSIBLE FOR DEMOLISHING AND REMOVING EXISTING CONSTRUCTION WHICH WILL INTERFERE WITH THEIR NEW WORK AND ANY TEMPORARY BRACING OR PERMANENT SUPPORT STRUCTURES. 4. WHEN EXISTING ELECTRICAL SERVICE, POWER, AND LIGHTING IS REMOVED, STUB BACK AND CAP AS REQUIRED IN AREAS BETWEEN EXISTING CONDITIONS AND NEW WORK. 5. ANY EXISTING ROOFTOP AIR CONDITIONING UNIT, ROOF CURBS AND ALL ASSOCIATED DUCTWORK, GRILLES, DIFFUSERS, HANGER, CONTROL WIRING, ELECTRICAL WIRING, CONDUITS, AND CONDUIT HANGERS, IF APPLICABLE PER PROJECT STORE SITE, TO REMAIN UNLESS NOTED OTHERWISE ON PLANS. REFER TO MECHANICAL DRAWINGS. 6. IN ACCORDANCE WITH THE DRAWINGS, THOSE ITEMS WHICH ARE REMOVED, AND ARE NOT RELOCATED OR REUSED, SHALL BE DISPOSED OF BY THE G.C. 7. PROVIDE AND INSTALL TEMPORARY BARRICADE. COORDINATE REQUIREMENTS WITH LANDLORD. ELEVATION SHOWN IS A REPRESENTATION OF INTENT. ACTUAL VINYL GRAPHIC ARTWORK IS TO BE SUBMITTED TO LANDLORD FOR REVIEW BY THE SUNGLASS HUT'S MARKETING DEPARTMENT FOR APPROVAL PRIOR TO PRODUCTION AND INSTALLATION. K TENANT TO SUPPLY GRAPHICS. COORDINATE WITH LANDLORD BARRICADE SIGNAGE REQUIREMENTS TURN IN BARRICADE TURN IN BARRICADE TURN IN BARRICADE 12'-0"± A.F.F. T.O. BARRICADE J A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150066 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect SEAL TEMPORARY BARRICADE 0'-0" A.F.F. H 1. BOSTON BARRICADE SHALL CONSTRUCT A TEMPORARY BARRICADE PER LL REQUIREMENTS. 2. BARRICADE IS TO BE 100% COMPLETE AND READY FOR GRAPHICS TO BE INSTALLED NOT MORE THAN TWO DAYS AFTER CONSTRUCTION START. G.C. TO CONTACT OWNERS REPRESENTATIVE UPON COMPLETION TO COORDINATE GRAPHICS INSTALLATION. 3. G.C. IS RESPONSIBLE FOR MAINTAINING BARRICADE DURING CONSTRUCTION. FINISH FLOOR BARRICADE PROVIDED BY BOSTON BARRICADE 20'-73 8"± 6'-114"± (UNFOLDED) 16'-114"± (UNFOLDED) 6'-114"± (UNFOLDED) 4. REMOVE BARRICADE WHEN 100% OF STOREFRONT IS COMPLETE ON THE EVENING BEFORE G.C.'S PUNCHLIST IS COMPLETED, PRIOR TO OWNER VERIFICATION, AND AFTER LANDLORD APPROVAL IS RECEIVED. CARE IS TO BE TAKEN WHEN DISASSEMBLING AND REMOVING BARRICADE. ON INTERIOR SIDE (STORE SIDE), PAPER WINDOWS WITH WHITE CONSTRUCTION PAPER OVER GLAZING ONLY. TRIM 1/2" OFF EDGES AND TAPE CONTINUOUSLY AROUND PERIMETER WITH WHITE TAPE. G.C. IS TO RESTORE NEUTRAL PIER(S), MALL FLOORING AND BULKHEAD TO A 'LIKE NEW' CONDITION AND FINISH. G G1 SCALE: BARRICADE ELEVATION 2'-07 8" L.L. TO L.L. 35'-312" L.L. TO L.L. F J H 17'-63 8" 5'-918" 12'-0" 2'-63 8" L.L. TO L.L. 22 10 4 12 9 15 26 S C 20 C1 8 3 1 26 S C 4'-0" CUSTOM FILLER PANEL 10 18 25 19 FROM LEASE LINE S C 15 4 6 S LEASE LINE. 5. EXISTING STOREFRONT SIGNAGE TO BE RELOCATED ONCE RECLADDING HAS BEEN FINISHED. 6. REMOVE EXISTING FLOORING MATERIAL. PATCH AND PREPARE FLOOR AS REQ'D TO PROVIDE SMOOTH FLOOR FOR NEW FLOORING PER PLAN ON SHEET A-103. CAP EXISTING MECHANICAL, PLUMBING AND ELECTRICAL SERVICES FLUSH WITH EXISTING SLAB AS REQ'D. 7. EXISTING PENDANT LIGHTING TO BE REMOVED. 11. EXISTING GYPSUM BOARD CEILING TO REMAIN, PATCH AND REPAIR AS REQUIRED. 13. ALL EXISTING PLUMBING FIXTURES TO REMAIN U.N.O. 14. EXISTING ELECTRICAL PANEL TO REMAIN. A1 10 8 15. EXISTING LIGHTING, CEILING DEVICES, ACCESS PANELS, SOFFITS AND CEILING SYSTEM TO REMAIN, U.N.O. REFER TO ELECTRICAL DRAWINGS. BARRICADE BY BOSTON BARRICADE. REFER TO VENDOR SHOP DRAWINGS 16. PENDANTS TO BE REMOVED, U.N.O. SEE SHEET A-104. 21 S C 2'-0" 21 5 17. EXISTING FLOOR OUTLETS TO REMAIN. COL 18. EXISTING SMOKE DETECTOR TO REMAIN, 19. EXISTING SPEAKER TO BE RELOCATED. 14 ADJACENT TENANT (N.I.C.) REMOVE EXISTING TRACK AND FIXTURES. 10. EXISTING DOOR TO REMAIN. CLEAN TO "LIKE NEW" CONDITION. 25 (E ) 26 C 8. EXISTING SOFFITS TO REMAIN. 9. 12. EXISTING WALL TO REMAIN. 11 17 26 OVERALL LEASE LINE 3 S FE 21. EXISTING MALL COLUMN TO REMAIN. LEASE LINE 9 3 B 22. LIGHTING PANEL TO BE REMOVED AND RELOCATED. REFER TO ELECTRICAL SHEETS. MALL COMMON AREA 1 RIVERCHASE GALLERIA 20. EXISTING SPEAKER TO REMAIN. 4 23. TRANSFORMER TO BE RELOCATED ABOVE CEILING. REFER TO ELECTRICAL SHEETS. G1 26. EXISTING SLOT DIFFUSERS TO REMAIN A-101 8 '-2 7 25. EXISTING RECESSED LIGHTS TO BE REMOVED 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM SGH STORE #: 4933 27. EXISTING GRAB BAR TO REMAIN. DRAWN BY: PWD VE 16 "L .L .T O 1 L.L RA 8'. LL 11 1 LE 2 " AS E LIN E 24. EXISTING PHONE BOARD TO REMAIN. REVIEWED BY: RJH/JRM O GRAPHICAL KEY AUTHORIZED FOR: EXIST. TO BE REMOVED U.N.O. EXIST. TO REMAIN U.N.O. L. 2 'L. 8 5 TO 8 " L. L. LAYOUT: A-101 P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\A-101_04933.dwg 2 " -0 4' PLOTTED: 7/9/2015 - 8:22 AM 18 REMOVE EXISTING CASHWRAP, FLOOR CASEWORK, AND ASSOCIATED ELECTRICAL & DATA HOOK-UP. REMOVE WIRING/ CONDUIT BACK TO SOURCE. 3. 7 (E) 12 " . 5 8 .L '-9 L L 3 1 RA L VE O USER: PDICKERSON 24 (E) GLAZING ASSEMBLY & FRAMING TO REMAIN. CLEAN TO "LIKE NEW" CONDITION. (E) STORE FRONT FINISHES TO BE REMOVED. AS REQUIRED TO ACCOMMODATE INSTALLATION OF NEW FINISH MATERIALS. 2. 4. EXISTING MILLWORK TO BE REMOVED. 9 13 S C D 4 8 14'-53 8" 3 11'-11" L.L. TO L.L. 3'-107 8" OVERALL L.L. E 3 27 17'-718" 14 1. AT KEY NOTES ADJACENT TENANT (N.I.C.) 23 RIVERCHASE GALLERIA 37'-43 8" OVERALL LEASE LINE A DEMOLITION / LEASE PLAN NORTH A1 SCALE: A-101 DEMOLITION / LEASE PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 3 4 5 ACCESSORY ID DESCRIPTION 8 1 GRAB BAR B-5806x42 BOBRICK GRAB BAR B-5806x36 BOBRICK 3 VERTICAL GRAB BAR B-5806x18 BOBRICK 4 MIRROR B-165 1836 BOBRICK ABOVE LAV. REFER TO G6/A-502 5 MIRROR B-165 2460 BOBRICK RESTROOM DOOR 6 TOILET TISSUE DISPENSER B-5543 BOBRICK NON-LOCKING 7 UTILITY HOOK B-2116 BOBRICK HOOK STRIP B-232x24 9 MOP HOLDER B-223x24 BOBRICK PAPER TOWEL DISPENSER KT1024 SIMPLE HUMAN 11 LAVATORY FAUCET 7038.101 AMERICAN STANDARD MODEL # MANUFACTURER LOCKERS(#) EMPLOYEE LOCKERS 36168/ 36368 LOCKERS.COM SAFE SMALL DROP SLOT SAFE UC-025K SENTRYSAFE MICRO MICROWAVE OVEN M01108SST AVANTI FRIDGE REFRIGERATOR RM3316B AVANTI XxYxZ PIPP SHELVING STORAGE SHELVING PIPP 11 COLOR: GRAY, LOCKS: 33390, # = NUMBER OF 12" WIDE UNITS TO BE LOCATED IN CASHWRAP COLOR: BLACK X = WIDTH, Y = DEPTH, Z = HEIGHT, SEE A7/A-502 8. GRAB BAR MIRROR (N) TOILET TISSUE DISPENSER (N) SE D SE D HOOK STRIP 14 10. 11. COORDINATE CORE DRILLING WITH MALL OPERATIONS MANAGER PRIOR TO BEGINNING WORK. PREPARE THE FLOOR SLAB AND PROCURE MATERIALS REQUIRED AT THE ENTRANCE TO PRODUCE A FLUSH CONDITION BETWEEN THE TENANT STORE CLOSURE LINE AND THE EXISTING MALL FLOORING. INSTALL ALL FINISH FLOORING (I.E.: CARPET, WOOD, TILE) AND ALL FINISH WALL MATERIALS BEHIND AND UNDER ALL MILLWORK. ADEQUATE ACCESS PANELS OR DOORS SHALL BE INCORPORATED INTO TENANT WORK FOR INSPECTION SERVICE AND REPLACEMENT OF BOTH LANDLORD AND TENANT EQUIPMENT, COORDINATE PLACEMENT WITH LANDLORD'S ON-SITE REPRESENTATIVE. PROVIDE 3/4" FIRE RETARDANT PLYWOOD BEHIND ALL ELECTRICAL AND TELEPHONE PANELS, PAINT TO MATCH WALL COLOR FINISH PRIOR TO HARDWARE INSTALLATION. PROVIDE EXPANSION BETWEEN ALL NEW WALLS AND THE EXISTING ROOF STRUCTURE ABOVE. PATCH/REPAIR ALL SURFACES (WALLS, FLOOR, CEILING, ETC.) AFFECTED BY DEMOLITION WORK. TRANSITIONS BETWEEN DISSIMILAR FLOOR MATERIALS TO BE SMOOTH AND FLUSH. REFER TO SHEET A-502 FOR FOR APPLICABLE FLOOR TRANSITION DETAILS. ALL FINISH MATERIALS SHALL BE INSTALLED PER MANUFACTURER'S STANDARD WRITTEN DETAILS AND SPECIFICATIONS. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. PROVIDE A LEVEL 4 GYP. BD. FINISH ON ALL NEW AND EXISTING WALLS. SEAL CONTROL JOINTS IN CONCRETE FLOORS. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150066 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect SEAL 4'-0" 6'-0" 4'-0" UTILITY HOOK (N) 13 NO TU 1'-7" MIN. MIRROR (E) NO TU 6'-2" 7"-9" 9. SE D PLAN VIEW NO TU 1'-4" MIN 1'-6" MAX EQUIPMENT SCHEDULE 3'-4" NO TU NO 3'-0" GRAB BAR (E) SE D SE D TU 3'-4" 3'-4" TU NO 3'-0" GRAB BAR (N) 4. 7. SCALE: SE D 3'-0" MIN CL 2'-0" 12" MIN MIN 1'-0" 2. 6. J8 3'-6" 1. 3. STAPLES #180969 TOILET ACCESSORY SCHEDULE H 12 GENERAL NOTES REMARKS BOBRICK J4 G 10 DESCRIPTION 5. 10 SCALE: 9 EQUIPMENT NAME REMARKS 2 8 J 7 MANUFACTURER 4'-0" K 6 MODEL # NO TU 2 SE D 1 MOP HOLDER (N) PAPER TOWEL DISPENSER (E) G4 SCALE: TOILET ACCESSORY MOUNTING HEIGHTS ADJACENT TENANT (N.I.C.) J 17'-63 8" H 3 2'-63 8" L.L. TO L.L. 102 1 3 EXISTING TENANT SEPARATION WALL TO REMAIN. G.C. SHALL PATCH/ REPAIR GYP BD. AS REQUIRED. MAINTAIN REQUIRED RATING. 4. CONCRETE MUST BE LEVEL AND CLEAN OF ANY FOREIGN MATERIALS PRIOR TO INSTALLING NEW FINISHED FLOORING. G.C. TO PERFORM MOISTURE BARRIER TEST BEFORE INSTALLING ANY FLOORING - REFER TO SPECIFICATIONS FOR MOISTURE TEST PROCEDURES 5. LINE OF SOFFIT ABOVE. 6. EXISTING ELECTRICAL DISTRIBUTION EQUIPMENT. REFER TO ELECTRICAL DRAWINGS. 7. NOT USED. 8. NOT USED. 17'-718" 4 1 14'-53 8" 5 100 D 2 5 SALES 5 OVERALL LEASE LINE 9. (E) 14 11'-11" L.L. TO L.L. C1 6 NOT USED. 10. NOT USED. 11. NOT USED. E8 12. NOT USED. A-401 13. NOT USED. 14. EXISTING PHONE BOARD. 15. NOT USED. 5 C (E ) 1 16. RELOCATED TRANSFORMER ABOVE. A1 MALL COMMON AREA (N.I.C.) 2'-0" 5 3 COL 14 5 LEASE LINE OVERHEAD LINEWORK WALL CONSTRUCTION WALL INFILL CONSTRUCTION EXISTING WALL CONSTRUCTION A1 8 "L .L .T O 18 L. ' L. LL -11 1 LE 2 " AS E LIN E RA O 16 '-2 7 2 VE B RIVERCHASE GALLERIA GRAPHICAL KEY 1 ADJACENT TENANT (N.I.C.) 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM SGH STORE #: 4933 DOOR WITH TYPE AND SIZE - SEE G-002 & D4/A-502 DRAWN BY: PWD E1 (E) A1 A-401 EXISTING DOOR WITH TYPE AND SIZE - SEE G-002 REVIEWED BY: RJH/JRM AUTHORIZED FOR: X L. 2 ' L . -8 5 TO 8 " L. L. PLOTTED: 7/9/2015 - 9:03 AM EXISTING STOREFRONT SYSTEM. 3. 1 " . 5 8 .L '-9 L L 3 1 RA L VE O P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\A-102_04933.dwg LAYOUT: A-102 3'-107 8" OVERALL L.L. E USER: PDICKERSON LEASE LINE. 2. 5'-918" 12'-0" TOILET ROOM 16 1. AT F KEY NOTES 2'-07 8" L.L. TO L.L. 35'-312" L.L. TO L.L. RIVERCHASE GALLERIA 37'-43 8" OVERALL LEASE LINE A NORTH FE PARTITION TYPE - SEE A8/A-503 FIRE EXTINGUISHER. FOR EXACT LOCATIONS AND REQUIREMENTS CONSULT WITH LOCAL FIRE DEPARTMENT INSPECTOR FLOOR PLAN A1 SCALE: A-102 FLOOR PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 FLOOR K J GR-01 GROUT FOR CERAMIC TILE LATTICRETE COLOR:45 RAVEN T-02 CERAMIC TILE ATLAS CONCORDE ATLAS CONCORDE EVOLVE COLOR: EVOLVE IRON FINISH: MATTE SIZE: 60x60 - 23 5/8”x23 5/8” GROUT SPACING: 1/8" VT-01 VINYL TILE ARMSTRONG COMMERCIAL FLOORING STANDARD EXCELON IMPERIAL TEXTURE COLOR: 51861 SOFT WARM GRAY SIZE: 12" x 12" x 1/8" 5 6 P-3 ACRYLIC PAINT BENJAMIN MOORE REGAL SELECT COLOR: 2132-10 BLACK SHEEN: SEMI-GLOSS P-4 ACRYLIC PAINT BENJAMIN MOORE REGAL SELECT COLOR: PM-1 SUPER WHITE SHEEN: SEMI-GLOSS P-6 ACRYLIC PAINT BENJAMIN MOORE REGAL SELECT COLOR: 2126-60 ANCHOR GRAY SHEEN: FLAT 7 8 9 10 11 12 13 14 GENERAL NOTES 1. PROVIDE AND INSTALL FIRE EXTINGUISHERS AS DIRECTED BY THE FIRE MARSHAL. (SUGGESTED LOCATIONS ON PLAN. IF EXISTING AND NOT CURRENT, CONTACT P.M. 2. EXAMINE ALL SURFACES TO BE PAINTED UNDER THIS CONTRACT AND SEE THAT THE WORK OF OTHER TRADES HAVE BEEN LEFT OR INSTALLED IN A SATISFACTORY CONDITION TO RECEIVE PAINT OR SPECIFIED FINISH. 3. MAINTAIN ALL FINISHES IN THE STORE, WALLS, FLOOR AND CEILING PRIOR TO TURNOVER. TOUCH-UP ALL CORNER BEADS, WALLS, CEILING AND FLOORING AS REQUIRED PRIOR TO TURNOVER AND ANY DAMAGE CAUSED BY OTHER TRADES INCLUDING MILLWORKER. 4. SEE SHEET A-201 FOR SALES ELEVATIONS AND FINISH DESIGNATIONS. 5. G.C. TO CLEAN EXISTING FLOORING TO 'LIKE NEW' CONDITION. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150066 STOREFRONT Shremshock Architects, Inc. MET-01 BASE HPL-06 DECOMETAL LAMINATE APPLIED TO WOOD BASE. FORMICA FINISH: BRUSHED ALUMINIUM VB-01 VINYL BASE JOHNSONITE 4" H. x 1/8" THICK COLOR: 38-PEWTER 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect ALUMINUM BRAKE METAL RETAIL STOREFRONT GROUP #063 ALUMINUM COLOR: TRANSFER BLACK FINISH: SEMI-GLOSS SEAL WALL P-1 ACRYLIC PAINT BENJAMIN MOORE REGAL SELECT COLOR: 2132-10 BLACK SHEEN: EGGSHELL P-2 ACRYLIC PAINT BENJAMIN MOORE REGAL SELECT COLOR: PM-1 SUPER WHITE SHEEN: EGGSHELL H KEY NOTES 1. H.C. ACCESSIBLE CASHWRAP. 6. SIGNAGE ABOVE. REFER TO ELEVATIONS. 7. (54) PRODUCT STORAGE TRAYS. FURNISHED BY OWNER, INSTALLED BY G.C. NOT USED. 11. NEW MOP HOLDER. REFER TO J4/A102 FOR ADDITIONAL INFORMATION FINISH MATERIAL SCHEDULE 12. NOT USED. J 15. NEW RETRACTABLE LAVATORY FAUCET. REFER TO J4/A102 FOR ADDITIONAL INFORMATION. 16. CUSTOM FILLER PANEL H 5'-918" 12'-0" ADJACENT TENANT (N.I.C.) 8 812" SP 10.8R SP 14.0-4 SP 10.5L ACCESSORY 6 1'-6" 17'-718" SP 10.5R A-201 E1 4' -0 " 100 EQ . A-201 3'-0" SALES 6 H1 14 H6 EQ . -1 CT SP 3' -0 " 6 3 RIVERCHASE GALLERIA W IN D O W " '-6 EQ COL 14 J6 SP 11 .5 R " '-2 " . 5 8 .L '-9 L L 3 1 RA L VE O SP 6) (3 11 .5 L 5 5. 13 1 C 2'-0" " '-0 7 ADJACENT TENANT (N.I.C.) MALL COMMON AREA (N.I.C.) CW 3.1L E6 CUSTOM FILLER PANEL TH EM E " 4' -0 15 -2 CT 8) (1 102 .4 11 TOILET ROOM SP 11 D 3' -6 " 4' -0 " A1 A-201 T 02 GR 01 14'-53 8" 5 J9 OVERALL LEASE LINE SP 10.5L 10 11'-11" L.L. TO L.L. 4 SP 10.0 ST SP 10.5R 2'-0" 2 7 SP 10.5L SP 10.4(18) STOREFRONT 16 18" MIN. ADJACENT TENANT (N.I.C.) 3'-6" 3'-107 8" OVERALL L.L. E AT 17'-63 8" 2'-63 8" L.L. TO L.L. F 14. SALES FLOOR MIRROR PROVIDED & INSTALLED BY MILLWORKER. G.C. TO PROVIDE BLOCKING AS REQUIRED. 2'-07 8" L.L. TO L.L. 35'-312" L.L. TO L.L. RIVERCHASE GALLERIA 13. START TILE (FULL TILE) CENTERED ON ENTRY AS SHOWN 37'-43 8" OVERALL LEASE LINE 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM TO 18 L. ' L. LL -11 1 LE 2 " AS E LIN E AL DI GIT 11 .8 L EQ B CAPACITY CALCULATIONS RA L. 2 ' L . -8 5 TO 8 " L. L. O VE 8" 16 '-2 7 L. L. SP LAYOUT: A-103 TYPICAL TOILET ROOM FINISHES: FLOOR: VT-01, BASE: VB-01, WALLS: P-2, DOORS: P-4, CEILING :EXISTING. 5. 9. SCALE: P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\A-103_04933.dwg NOT USED. 4. 10. NEW DOOR MIRROR. REFER TO J4/A102 & J4/A-502 FOR ADDITIONAL INFORMATION G1 PLOTTED: 7/9/2015 - 9:03 AM TECH RACK & SECURITY SHELVES FOR EQUIPMENT/MUZAK ( IN BACK WRAP). 3. 8. (N) GRAB BAR G USER: PDICKERSON NOT USED. 2. A NORTH A1 SCALE: FIXTURE ID THEME CT-HC CT-1 CT-2 FS 1.0 GO 1.0 SP 10.0 SP 10.1 SP10.0 ST SP 11.0 SP 11.1 STORY PANEL FIXTURE QUANTITY 1 0 1 1 0 0 3 1 1 3 2 0 FIXTURE CAPACITY 0 0 0 0 52 104 80 40 80 80 40 -26 TOTAL TOTAL FACINGS 0 0 0 0 0 0 240 40 80 240 80 0 680 2 REVIEWED BY: RJH/JRM AUTHORIZED FOR: FINISH / FIXTURE PLAN A-103 FINISH/FIXTURE PLAN 1 SGH STORE #: 4933 DRAWN BY: PWD 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 GENERAL NOTES 1. 2. REFER TO LIGHTING SPECIFICATIONS SCHEDULE FOR ADDITIONAL INFORMATION. GRID LAYOUT FOR ACOUSTICAL CEILING TILE TO BE CENTRALLY LOCATED WITHIN RETAIL SPACE AS INDICATED AT PLAN LAYOUT UNLESS SPECIFICALLY NOTED OTHERWISE. REFER TO PLAN LAYOUT FOR EQUAL/EQUAL DIMENSIONS TO BE MAINTAINED. 3. IT SHALL BE THE E.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE E.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. 4. E.C. SHALL RE-LAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD. 5. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR AIMING TRACK HEADS PER SGH STANDARDS. ELECTRICAL CONTRACTOR TO CONTACT LUXOTTICA PM FOR FOCUSING DIRECTIVE IF NEEDED. 6. G.C. IS RESPONSIBLE TO PATCH/REPAIR ALL GYP.BD. CEILING SURFACES AFFECTED BY DEMOLITION/NEW CONSTRUCTION. 7. EXISTING GYP.BD. CEILING SURFACES TO RECEIVE A FRESH COAT OF PAINT UPON COMPLETION OF SCOPE OF CEILING WORK. LIGHTING INSTALLER IS RESPONSIBLE TO TOUCH UP ANY AREAS DAMAGED BY THEIR WORK. 8. CENTER CEILING GRID & CEILING DEVICES U.N.O. 9. SPRINKLER HEADS SHOWN FOR REFERENCE ONLY. FIRE PROTECTION CONTRACTOR TO DETERMINE ACTUAL AMOUNT AND LOCATION OF HEADS. SPRINKLER HEADS SHOULD BE LOCATED SYMMETRICALLY IN THE CEILING AND SURFACE MOUNTED WHEN APPLICABLE. K J (E) GYP CEILING A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150066 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect SEAL 9'-0" A.F.F. B.O. SALES CEILING DISPLAY GRID (REFER TO CEILING PLAN). HARDWARE AND ANCHORS PROVIDED WITH GRID. USE 6 HOOKS PER 5' LONG SECTION OF GRID. EXISTING MALL BULKHEAD EXISTING STOREFRONT SYSTEM 8" MIN G 6. TRACK LIGHT - REFER TO ELECTRICAL SHEETS 7. 1'-4" HOLD GRAPHIC GRID OWNER PROVIDED. G.C. INSTALLED, COORDINATE TO MATCH CEILING 8. NOT USED. 9. NOT USED. 10. NOT USED. 11. RELOCATED LIGHT FIXTURE. GRAPHICS GRID DETAIL 12. NOT USED. 13. LIGHT FIXTURE TRIM TO MATCH SOFFIT COLOR. 2'-07 8" L.L. TO L.L. 35'-312" L.L. TO L.L. J H 2'-63 8" L.L. TO L.L. (E) GYP(P-2) 10'-4" AFF OVERALL LEASE LINE 14'-53 8" 11'-11" L.L. TO L.L. 17'-718" A3W A3B 2'-0" 6 " '-0 W A3 W A3 W A3 (E) 13 L. 2 ' L . -8 5 TO 8 " L. L. O VE 16 '-2 7 A3B L. L. TO 18 L. '-1 L. 11 LE 2 " AS E LIN E W A3 A3W (E) A NORTH A1 2 X4 RECESSED ADJUSTABLE DOWN LIGHT C1B RECESSED ADJUSTABLE DOWN LIGHT (BLACK) C4W RECESSED ADJUSTABLE DOWN LIGHT (WHITE) C4B RECESSED ADJUSTABLE DOWN LIGHT (BLACK) B1 2x2 LED RECESSED MOUNT B2 2x4 LED RECESSED MOUNT EXIT & EMERGENCY LIGHT COMBINATION EMERGENCY LIGHT REMOTE POWER SUPPLY ADJUSTABLE TRACK HEAD (WHITE) ADJUSTABLE TRACK HEAD (BLACK) C1W EXIT SIGN A P TC (E) (R) 3 4 5 6 7 8 9 10 11 TRAFFIC COUNTER EXISTING RELOCATION 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM S C SECURITY CAMERA S SPEAKER SGH STORE #: 4933 S SMOKE DETECTOR DRAWN BY: PWD REVIEWED BY: RJH/JRM AUTHORIZED FOR: REFLECTED CEILING PLAN 4'-1 LED STRIP SUSPENDED B3 AT 13'-0" A.F.F. CONCEALED SPRINKLER HEAD 12 RIVERCHASE GALLERIA WIRELESS ACCESS POINT A-104 UPRIGHT SPRINKLER HEAD REFLECTED CEILING PLAN 1 LIGHT TRACK w/ LENGTH (BLACK) TB (E) GYP (P-1) 9'-0" AFF X3 LIGHT TRACK w/ LENGTH TW 14 W " COL LL W A3 '-0 RECEPTACLE DUPLEX 13 B X2 EXHAUST FAN 6 )T (N " . 5 8 .L '-9 L L 3 1 RA L VE O 4 A3B (E) (E) (E) X1B EXIT LIGHT (BLACK) SUPPLY DIFFUSER 2 4 ADJACENT TENANT (N.I.C.) A3B A3 B S S C (E) X1A EXIT LIGHT - CEILING MOUNTED X1 EXIT LIGHT RETURN AIR GRILLE (R) (E) (E) (E) FIXTURE EXTENTS BELOW RA W A3 (E) (R) SYMBOLS LEGEND / GRAPHICAL KEY 8" W A3 11 G1 A-104 MALL COMMON AREA (N.I.C.) A X1 W A3 (E) 13 TB5'-0" (E) (E) 13 A3 B 100 " SALES 6' -0 W A3 (E) 7 S C 1 A3 B W A3 A3 W (E) GYP(P-2) 12'-0" AFF P " 4' -0 " W A3 A3 W 6 11 A (E) 2 (R) 3 S C (E) A3 W (E) GYP(P-1) 10'-4" AFF C (E) 6 4 " '-0 W A3 102 (E) (E) (E) S (E) (E) GYP(P-1) 9'-0" AFF 1'-1" (E) (E) (E) GYP(P-2) 10'-4" AFF (E) A3W A3W A3W EQ(N) TW6'-0" (E) 10 TOILET ROOM 4 (E) TW W A3 6 (E) (E) A3W A3W TW S (N) S C D (N) TW5'-0" EQ (E) (E) 2 A3W A3W A3W A3W A3W '-7 (E) (E) GYP(P-2) 11'-4" AFF A3W A3W A3W (N) TW8'-0" FE (E) (E) ACT- EXISTING 11'-6" AFF A3W A3W A3W 2 S C 1'-11" 3'-6" (E) 4'-0" 13 6 4'-0" 3'-107 8" OVERALL L.L. E ADJACENT TENANT (N.I.C.) AT 5'-918" 12'-0" ADJACENT TENANT (N.I.C.) LAYOUT: A-104 SECURITY CAMERAS. UNDERSIDE OF SOFFIT 17'-63 8" P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\A-104_04933.dwg NOT USED. FINISH, FIELD CUT TO THE DIM. AS SHOWN. CENTER IN DISPLAY WINDOW & MOUNT TO F PLOTTED: 7/9/2015 - 8:38 AM LOCATION OF WIRELESS ACCESS POINT. REFER TO E-102. LEASE LINE 37'-43 8" USER: PDICKERSON PREFERRED SPEAKER LOCATION. SPEAKER TO MATCH CEILING COLOR. 3. 5. OVERALL LEASE LINE SCALE: LOCATION OF TRAFFIC COUNTER (SHOPPER TRAK). REFER TO E-102. 2. 4. (E) ACCESS PANELS. G1 SCALE: 1. RIVERCHASE GALLERIA H KEY NOTES 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 GENERAL NOTES P P 2 K B.O. CEILING 12'-0" AFF B.O. CEILING 12'-0" AFF B.O. CEILING 10'-4" AFF B.O. CEILING 10'-4" AFF T.O. STOREFRONT 9'-0" AFF T.O. STOREFRONT 9'-0" P 2 1. REFER TO OWNER'S SIGNAGE STANDARD FOR ADDITIONAL SIGN INFORMATION. SIGNAGE WORK TO BE SUBMITTED UNDER SEPARATE PERMIT. 2. SEE SHEET A-103 FOR FINISH MATERIAL SCHEDULE A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT150066 # CUSTOM FILLER PANEL 1 DIGITAL TOOL P 2 SP 11.0 SP 11.5L SP 11.8L SP 11.5R J SP 11.0 SP 5.5 (36) FINISH FLOOR 0'-0" AFF SP 11.0 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect FINISH FLOOR 0'-0" AFF SEAL SP 11.4(18) HPL06 H H1 H6 SCALE: ELEVATION P 2 P B.O. CEILING 12'-0" AFF B.O. CEILING 12'-0" AFF B.O. CEILING 10'-4" AFF T.O. STOREFRONT 9'-0" AFF B.O. CEILING 10'-4" AFF 2 P 1 P 2 B.O. CEILING 11'-4" T.O. STOREFRONT 9'-0" FINISH FLOOR 0'-0" AFF FINISH FLOOR 0'-0" AFF SP 10.5L SP 10.0 ST HPL06 P 1 SP 10.8R SP10.5L SP10.5R F STOREFRONT CUSTOM FILLER PANEL SP 10.0 SP 10.4(18) SP 10.0 SP 10.5R SP 14.0-4 SP 10.5L SP 10.0 AT G ELEVATION HPL06 HPL06 E E1 USER: PDICKERSON E6 SCALE: ELEVATION ELEVATION D P C ON BOTH SIDES OF DOOR & FRAME P 3 P 1 1 SIGNAGE MATRIX B.O. CEILING 12'-0" AFF B.O. CEILING 10'-4" AFF TYPE ID QTY. REMARKS BARRICADE VINYL 1 BY BOSTON BARRICADE STOREFRONT - - BY SIGN VENDOR BLADE SIGN SGH.BL-1 SGH.BL-2 1 BY SIGN VENDOR CRASH GRAPHICS SGH-CGL 2 BY SIGN VENDOR B PLOTTED: 7/9/2015 - 8:41 AM P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\A-201_04933.dwg LAYOUT: A-201 SCALE: RIVERCHASE GALLERIA SCALE: SGH STORE #:4933 REVIEWED BY:RJH/JRM HPL06 A A1 A6 SCALE: ELEVATION 1 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM DRAWN BY:PWD FINISH FLOOR 0'-0" AFF SCALE: RIVERCHASE GALLERIA 2 3 4 5 BACKWRAP SGH.BW 1 BY MILLWORKER IDENTIFICATION SIGN SGH.ID - BY MILLWORKER VINYL DOT PATTERN - - BY SIGN VENDOR NOT USED 6 7 8 9 10 11 12 13 14 AUTHORIZED FOR: ELEVATIONS A-201 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 K CONSULTANT PROJECT # 150066 RELOCATE EXISTING SIGN AFTER RECLADDING IS COMPLETE MET-01 Shremshock Architects, Inc. J 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect (N)BLADE SIGN MET-01 SEAL B.O. L.L. BULKHEAD 10'-10" A.F.F. B.O. L.L. BULKHEAD 10'-10" A.F.F. SIM. H B.O. SOFFIT 8'-10" A.F.F. LEASE LINE H11 LEASE LINE 5'-0" EXISTING STOREFRONT GLAZING TO REMAIN F LINE OF FIXTURES BEYOND T.O. STOREFRONT BASE 0'-6" A.F.F. T.O. STOREFRONT BASE 0'-6" A.F.F. FINISH FLOOR 0'-0" A.F.F. FINISH FLOOR 0'-0" A.F.F. TURN IN STOREFRONT LINE OF FIXTURES BEYOND E (E) STOREFRONT SYSTEM TURN IN STOREFRONT (E) ENTRY DOORS TURN IN STOREFRONT E1 USER: PDICKERSON PLOTTED: 7/9/2015 - 10:12 AM P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\A-401_04933.dwg LAYOUT: Model SCALE: TURN IN STOREFRONT STOREFRONT SIGNAGE DRAWINGS TO BE SUBMITTED UNDER SEPARATE COVER AT TURN IN STOREFRONT TURN IN STOREFRONT E8 SCALE: STOREFRONT ELEVATION STOREFRONT ELEVATION RIVERCHASE GALLERIA EXISTING STOREFRONT GLAZING TO REMAIN G D C RIVERCHASE GALLERIA 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM B SGH STORE #: 4933 DRAWN BY: PWD REVIEWED BY: RJH AUTHORIZED FOR: A STOREFRONT PLAN & ELEVATION A1 SCALE: A-401 NOT USED 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 4" W. X 18 GA CONTINUOUS SHEET METAL BLOCKING WITH TOGGLE BOLTS. IF TOGGLE BOLTS CANNOT BE USED, (EX: THE HAT CHANNEL SITES IN THE WAY OF THE TRACK), THEN FLAT HEAD SCREWS MATCHING SPIDER TRACK ARE TO BE USED FOR FLUSH MOUNTING REFER TO SECTIONS FOR FRAMING A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 K J T NO 1 1/2" 5/8" TYPE 'X' GYP. BD. OVER 3 5/8" METAL STUDS, TYP. 1/2" CORIAN ON 3/4" F.R.T. PLYWOOD OVER 3 5/8" METAL STUDS, TYP. ED US HATCH INDICATES EXISTING TENANT CONSTRUCTION TO REMAIN B.O. BULKHEAD REFER TO SECTIONS F.R.T. BLOCKING AS REQUIRED T.O. ENTRY CEILING REFER TO SECTIONS METAL PANEL OVER 3/4" PLYWOOD SHEATHING INSTALLED BY G.C. E11 A-501 9 3/4" H MET 01 MET 01 METAL PANEL OVER 3/4" PLYWOOD SHEATHING INSTALLED BY G.C. SEAL 4" BACKER ROD & SEALANT 1'-8 1/2" H1 SCALE: Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect EXISTING DOOR SYSTEM HEADER TO REMAIN HATCH INDICATES EXISTING TENANT CONSTRUCTION TO REMAIN 5" CONSULTANT PROJECT # 150066 BACKER ROD & SEALANT H8 SCALE: STOREFRONT DETAIL H11 SCALE: STOREFRONT DETAIL DOOR HEAD DETAIL G METAL PANEL OVER 3/4" PLYWOOD SHEATHING INSTALLED BY G.C. HATCH INDICATES EXISTING TENANT CONSTRUCTION TO REMAIN F BACKER ROD & SEALANT BACKER ROD & SEALANT AT F.R.T. BLOCKING AS REQUIRED METAL PANEL OVER 3/4" PLYWOOD SHEATHING INSTALLED BY G.C. E MET 01 E8 E11 SCALE: STOREFRONT DETAIL STOREFRONT HEAD DETAIL LAYOUT: A-501 SCALE: RIVERCHASE GALLERIA MET 01 EXISTING CONSTRUCTION FINISHES, PATCH AND REPAIR TO LIKE NEW CONDITION AS REQUIRED. USER: PDICKERSON PLOTTED: 7/9/2015 - 10:14 AM P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\A-501_04933.dwg D C RIVERCHASE GALLERIA 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM B SGH STORE #: 4933 DRAWN BY: JLG REVIEWED BY: RJH/JRM AUTHORIZED FOR: A STOREFRONT DETAILS A1 E8 E11 SCALE: SCALE: SCALE: NOT USED 1 2 3 4 5 6 7 NOT USED 8 9 10 11 A-501 NOT USED 12 13 14 3 4 5 6 J-CHANNEL G.C. TO MECHANICALLY FASTEN (EVERY 12"-18") THE TOP, BOTTOM, AND ONE SIDE J-CHANNEL, SLIDE MIRROR IN (WITH MIRROR MASTIC) AND ATTACH THE OTHER SIDE J-CHANNEL. GC TO USE ANCHORS AS REQUIRED TO SECURELY FASTEN. K 7 8 10 11 12 13 1/8" THICK ZINC TRANSITION STRIP FURNISHED AND INSTALLED BY TILE CONTRACTOR. FLASH PATCH BY G.C. BOBRICK B-1651836 MIRROR WITH STAINLESS STEEL CHANNEL FRAME 18" ATTACH WALL HANGER TO IN-WALL BLOCKING W/ #8 X 1 1/2" F/H MTL SCREWS WHERE REQUIRED, TYP. J4 J9 SCALE: 36" CONSULTANT PROJECT # 150066 THIN SET MORTAR BED NOTE: PREPARE EXISTING CONCRETE SLAB AS REQUIRED TO PROVIDE LEVEL TRANSITION TO MALL FLOORING DOOR MIRROR DETAIL A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 TILE FLOORING PER PLANS & SCHEDULE LINE OF EXISTING CONCRETE SLAB THIN SET MORTAR BED NO T PROVIDE IN-WALL BLOCKING AS REQUIRED DOOR J 1/8" THICK ZINC TRANSITION STRIP FURNISHED AND INSTALLED BY TILE CONTRACTOR. TILE FLOORING PER PLANS & SCHEDULE LINE OF EXISTING CONCRETE SLAB 14 D SE U T NO 36" MIN. TAPER VINYL TILE MIRROR BY G.C. SCALE: 9 212" 2 US ED 1 NOTE: PREPARE EXISTING CONCRETE SLAB AS REQUIRED TO PROVIDE LEVEL TRANSITION TO MALL FLOORING FLOOR TRANSITION VCT TO PORCELAIN TILE J12 SCALE: Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect FLOOR TRANSITION TILE TO TILE ED US SEAL DOOR T NO (E) MALL FLOORING. FIELD VERIFY TYPE. LINE OF EXISTING CONCRETE SLAB 412" NOTE: PREPARE EXISTING CONCRETE SLAB AS REQUIRED TO PROVIDE LEVEL TRANSITION TO MALL FLOORING G G1 G4 SCALE: G6 SCALE: NOT USED SCALE: NOT USED J6 SCALE: RESTROOM MIRROR DETAIL G12 SCALE: FLOOR TRANSITION CONCRETE TO VINYL B.O. (E) ROOF DECK / STRUCTURE OR (E) FLOOR DECK / STRUCTURE F ALL CAT 6 AND CAMERA CABLING TO BE RAN INSIDE WALL BEHIND TECH RACK T NO 24" W. x 18" D. SHELVING RATED TO 100 LBS (TYP.) ON 60" WHITE DOUBLE SLOTTED STANDARDS 24" W 8" D SHELF MONITOR, KEYBOARD AND MOUSE ON SHELF 5/8" GYPSUM BOARD SEE WALL TYPE FOR FRAMING T NO FASTENING TO STRUCTURE ABOVE TO COMPLY WITH LANDLORD AND OR LOCAL BUILDING DEPARTMENT REQUIREMENTS. ED S U CONFORM TO BASIC MINIMUM REQUIREMENTS ESTABLISHED IN ASTM C636 12 PORT PATCH PANEL 10" SAFE 2'-0" 1'-6" TECH RACK D4 PHONE BOARD/SECURITY ELEVATION SCALE: T NO ED S U 17-19" ED S U CONCEALED CONTINUOUS HINGE T NO ED S U SGH STORE #: 4933 2'-1114" 1'-05 8" 3 SIDE 3 4" 3 SCALE: 4 5 6 A11 SCALE: PIPP SHELVING 7 8 9 10 AUTHORIZED FOR: 4" ACCESS PANEL WITH METAL DOOR. FINISH TO MATCH CEILING. SHELF SPACING AND BIN ARRANGEMENTS CEILING MOUNTED ACCESS PANEL METAL FLUSH MOUNTED 11 12 13 DRAWN BY: PWD REVIEWED BY: RJH/JRM SCREWDRIVER OPERATED LATCH. VARIES REFER TO CLG PLAN 1'-65 8" 1'-1114" A7 DISABLED ACCESS SIGNAGE RIVERCHASE GALLERIA REFER TO CEILING PLAN VARIES 5/8" GYP. BD. FRONT SCALE: ATTACH WITH #8 SHEET METAL SCREWS. 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM 3'-1114" TYPICAL LAVATORY/SHELVING ELEVATION 2 T NO 1'-6" LAVATORY, REFER TO PLUMBING DRAWINGS A4 1 7'-1118" RESTROOM BRAILLE SIGN PER 1991 ADA REQ'TS 4'-8" 9" 29" MIN 27" MIN 34" MIN RE ST ROOM FRAMING AS REQUIRED. REFER TO SPECIFIC DETAILS AND STRUCTURAL DRAWINGS. METAL TRIM A1 SCALE: ANSI APPROVED E.S. PLASTIC NEMA RATED SELF EXTINGUISHING ADHESIVE MOUNTED 40" MIN 60" MAX 8'-0" 40" MAX INSULATE HOT WATER AND DRAIN PIPING SUSPENDED GYP. BD. CEILING DETAIL INSTALLATION ON VERTICAL WALL TO BE SIMILAR. ALL FASTENER REQUIREMENTS AND SPECIFICATIONS ARE THE SAME. NOTE: ALL SIGNAGE SHALL CONFORM WITH ADA ACCESSIBILITY GUIDELINES, INCLUDING BUT NOT LIMITED TO PROPORTION, COLOR CONTRAST AND RELIEF AND GRADE 2 BRAILLE REQUIREMENTS. 2'-0" 0.C. A D11 BRACKET BLUE B FASTENING TO STRUCTURE ABOVE TO COMPLY WITH LANDLORD AND OR LOCAL BUILDING DEPARTMENT REQUIREMENTS. ALIGN 3'-0" CL 5/8" GYP. BD. 'TYPE X' 1/2" SHELF VARIES REFER TO PLAN MIRROR, REFER TO G6/A-502 1 1/2" CHANNEL 4'-0" O.C. MAX. G.C. IS TO PROVIDE A ONE-HOUR FIRE RATED CEILING SYSTEM (WHEN-REQUIRED). REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS. SCALE: ACOUSTICAL CEILING TILE 12" 12" 12" 12" 12" 12" O.C. O.C. O.C. O.C. O.C. O.C. C D SE U T NO 20 GA. METAL STUD WITH 1 5/8" FLANGE AND 1/2" LIPS. (MIN.) STANDARD STORES (LOW SEISMIC) IBC SEISMIC DESIGN CATEGORIES A,B&C D7 SCALE: 3'-0" WIDE X 2" DEEP X 3/4" THICK WHITE MELAMINE SHELVING, FINISHED ON ALL SURFACES WITH WHITE DOUBLE SLOTTED BRACKETS & STANDARDS. FASTEN SHELVES TO BRACKETS REFER TO G4/A-102 FOR TOILET ACCESSORY MOUNTING HEIGHTS,TYP. METAL FURRING CHANNEL CLIP INTERMEDIATE DUTY SUSPENDED GRID SYSTEM CROSS "T" MEMBER @ 2'-0" OR 4'-0" O.C. (REFER TO SPECIFIC CEILING TYPE). WALL MOLDING. SIZE TO MATCH SIZE OF MAIN RUNNERS HOLLOW METAL JAMB / HEAD DETAIL HANGER SPACING 4'-0" O.C. MAX. 24" O.C. MAX. SPACING WALL OR SOFFIT FRAMING AND FINISHES. REFER TO SPECIFIC DETAILS. D1 SCALE: MINIMUM OF 3 TIGHT TURNS AT ALL WIRES. REFER TO CEILING PLAN VARIES HOLLOW METAL FRAME 24" W. X 48" H. PHONE BOARD 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EA. WAY. AND MAX. 8" FROM ALL EDGES. SEE COMPRESSION STRUT DETAIL FOR SEISMIC CONDITIONS D, E & F. ON A-505 INTERMEDIATE DUTY SUSPENDED GRID SYSTEM MAIN RUNNER @ 2'-0" O.C. ACOUSTICAL CEILING TILES DOUBLE QUAD OUTLET 3" 3'-0" 4'-0" D 33"-36" LAYOUT: A-502 P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\A-502_04933.dwg PLOTTED: 7/9/2015 - 10:19 AM USER: PDICKERSON DEDICATED QUAD OUTLET BEHIND TECH RACK FRIDGE 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EA. WAY. AND MAX. 8" FROM ALL EDGES. MINIMUM OF 3 TIGHT TURNS AT ALL WIRES. DSL MONITOR MICRO VARIES A66 PHONE BLOCK MICROWAVE AND REFRIGERATOR BY TENANT T NO 8" MAX. AT PERIMETER CLEAR SPACE FOR ELECTRICAL PANEL ANGLE BRACKET OR CLIP. ATTACH PER MANUFACTURER RECOMMENDATIONS. ED US 1 1/2" MAX E ED S U LINE OF EXISTING CONCRETE SLAB NOTE: PREPARE EXISTING CONCRETE SLAB AS REQUIRED TO PROVIDE LEVEL TRANSITION TO MALL FLOORING FLOOR TRANSITION TILE TO MALL VINYL TILE AT G.C. TO ADJUST SETTING BED AS REQUIRED TO ACHIEVE FLUSH TRANSITION ALUMINUM THRESHOLD PROVIDE LATEX LEVELING COMPOUND AS REQUIRED TO CREATE FLUSH CONDITION AT THRESHOLD. RIVERCHASE GALLERIA TILE FLOORING PER PLANS & SCHEDULE 37 8" H 1/8" THICK ZINC TRANSITION STRIP FURNISHED AND INSTALLED BY TILE CONTRACTOR. 1 " 4 LOCKING DEVICES AUTOMATICALLY SECURE MIRROR TO CONCEALED WALL HANGER WHEN IT IS LOWERED INTO FINAL POSITION, TYP. GENERAL DETAILS A-502 14 3 4 5 A. 1. DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE COMPLIMENTARY. SPECIFIC INFORMATION MAY BE FOUND IN EITHER OR BOTH. 2. THE TERM 'OWNER' AS STATED IN THE FOLLOWING SPECIFICATIONS AND CONSTRUCTION DOCUMENTS, REFERS TO THE TENANT OF THIS SPACE ONLY AND DOES NOT REFER TO THE LANDLORD OF THE PREMISES. 3. APPROVED VARIANCES TO THE PLANS AND SPECIFICATIONS ON ONE PROJECT SHALL NOT CONSTITUTE AN APPROVAL OF LIKE VARIANCES ON SUBSEQUENT PROJECTS. K B. C. D. E. B. 1. THE CONTRACTOR SHALL FURNISH FULL TIME CONTINUOUS SUPERVISION. THE PROJECT SUPERINTENDENT SHALL REMAIN ON SITE THROUGH THE MERCHANDISE DATE OR THE COMPLETION OF THE PUNCHLIST WHICHEVER IS LAST TO OCCUR. 2. SUSPENSION OF ALL CEILING AND OVERHEAD FRAMING IS TO BE FROM STRUCTURAL MALL BEAMS AND TOP CHORD OF TRUSSES ONLY, NOT FROM MALL DECK. 3. GENERAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF IN-WALL BLOCKING FOR ALL ITEMS IN STORE. REVIEW DRAWINGS THOROUGHLY. 4. ALL OWNER-FURNISHED MATERIALS ARE FURNISHED TAILGATE DELIVERY ONLY. THE CONTRACTOR IS RESPONSIBLE TO UNLOAD, EXAMINE, AND TRANSPORT MATERIALS FROM THE POINT OF OFF-LOAD TO THE JOBSITE OR STORAGE AREA AS APPLICABLE. MATERIALS WILL BE DELIVERED TO THE CLOSEST AVAILABLE TRUCK DOCK OR OTHER LOCATION AS DIRECTED BY THE LANDLORD. 5. THE CONTRACTOR IS RESPONSIBLE FOR DAMAGE, LOSS, THEFT, OR DESTRUCTION OF ALL OWNER-FURNISHED MATERIALS. THE CONTRACTOR WILL BE BACK-CHARGED THE FULL COST OF REPLACEMENT MATERIALS INCLUDING FREIGHT CHARGES. 6. THE GENERAL CONTRACTOR SHALL EMPLOY SUBCONTRACTORS WHO ARE EXPERIENCED AND WHO EMPLOY EXPERIENCED TRADESMEN. 7. THE GENERAL CONTRACTOR SHALL NOT EMPLOY NOISY CONSTRUCTION TECHNIQUES OR EQUIPMENT DURING MALL OR STORE HOURS. 8. THE CONTRACTORS SHALL WORK IN COOPERATION AND HARMONY WITH THE LANDLORD AND THE ADJACENT TENANTS IN SCHEDULING WORK IN ORDER TO CAUSE THE LEAST INCONVENIENCE TO PERSONNEL AND PROPERTY. IF SECURITY IS REQUIRED WHILE WORKING IN ADJACENT TENANTS SPACE, THIS COST WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 9. THE CONTRACTOR SHALL NOT UTILIZE GAS-OPERATED EQUIPMENT IN OCCUPIED SHOPPING CENTERS. THE CONTRACTOR SHALL WORK IN HARMONY WITH THE LANDLORD'S REQUIREMENTS RELATING TO NOISE ABATEMENT AND SAFETY. 10. THE CONTRACTOR SHALL FURNISH DUMPSTERS AS REQUIRED FOR THE EXCLUSIVE USE BY STORE PERSONNEL DURING MERCHANDISING. THE CONTRACTOR SHALL INCLUDE IN THE BID A MINIMUM OF ONE 40-YARD DUMPSTER OR THE EQUIVALENT. IF THE SALES AREA EXCEEDS 8,000 SQUARE FEET, THE CONTRACTOR SHALL INCLUDE ONE ADDITIONAL DUMPSTER. J H F. C. 1. EXERCISE PROPER PRECAUTION TO VERIFY ALL EXISTING CONDITIONS AND LAYOUT OF WORK. CONTRACTOR TO NOTIFY OWNER'S CONSTRUCTION MANAGER OF ANY DISCREPANCIES IMMEDIATELY. CONTRACTOR IS RESPONSIBLE FOR ANY ERROR RESULTING FROM FAILURE TO EXERCISE SUCH PRECAUTION. SUCH ERROR WILL NOT BE CONSIDERED SUBSEQUENTLY AS A BASIS FOR EXTRA COMPENSATION. 2. SHOULD A CONTRACTOR FIND DISCREPANCIES IN, OR OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS, OR SHOULD HE BE IN DOUBT AS TO THEIR MEANING, HE SHALL AT ONCE NOTIFY THE OWNER'S CONSTRUCTION MANAGER. 3. GENERAL CONTRACTOR IS RESPONSIBLE FOR SUPPLYING OR RENTING ALL TOOLS, WELDERS, GENERATORS, ETC. FOR COMPLETING PROJECT. G D. 1. ALL WORK, MATERIALS AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH ALL ORDINANCES, STATE AND LOCAL BUILDING CODES, LATEST EDITION, AND FOLLOW APPLICABLE LANDLORD REQUIREMENTS. 2. DESIGN LOADS: LOADS AND CODE RESTRICTIONS FOR ALL DESIGN CONSIDERATIONS SHALL CONFORM TO THE LOCAL AND STATE CODES, AND ALL GOVERNING CODES. F. E. F 1. THE AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT A201 "GENERAL CONDITIONS OF THE CONTRACTOR FOR CONSTRUCTION" IS A PART OF THE CONTRACT DOCUMENTS. 6 EQUATION TO DETERMINE VAPOR EMISSION IN POUNDS: 1. 2. E 3. USER: PDICKERSON PLOTTED: 7/9/2015 - 8:47 AM P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\A-701_04933.dwg LAYOUT: A-702 4. 5. D 6. C 7. 8. 9. 10. 11. B 12. TOTAL HOURS POUNDS PER 1,000 SQUARE FEET IN 24 HOURS THE VAPRECISION ANHYDROUS CALCIUM CHLORIDE TEST KIT, INSTRUCTIONS, CALCULATIONS AND ALL OTHER PRINTED INFORMATION ARE PROPERTY OF VAPRECISION TESTING SYSTEMS, COPYRIGHT 1994. REVISED AUGUST 1999. THE VAPRECISION ANHYDROUS CALCIUM CHLORIDE TEST KIT CONFORMS TO THE AMERICAN SOCIETY FOR TESTING & MATERIALS DOCUMENTATION ASTM E-1907-97 AND ASTM-F_1869-98 AND IS ACTUALLY PICTURED IN THE ASTM E-1907 SPECIFICATION. ASTM DOCUMENTS ARE THE COPYRIGHT PROPERTY OF ASTM, AND CAN BE PURCHASED EASILY FROM THEIR WEB SITE AT WWW.ASTM.ORG. : THE FORMULA ABOVE COMPLIES TO ASTM DOCUMENTATION AS OF 8/99 AND DEDUCTS THE AREA OF THE CALCIUM CHLORIDE DISH IN CONTACT WITH THE SLAB. THERE IS A DEBATE REGARDING THIS ISSUE. TO CALCULATE THE TEST RESULT WITHOUT DEDUCTING THE AREA OF THE DISH, USE 108.846 INSTEAD OF 118.932. A. THE CONTRACTOR SHALL ACCOMPLISH ANY MISCELLANEOUS MASONRY WORK INDICATED ON THE PLANS, OR NOT INDICATED ON THE PLANS YET INCIDENTAL TO THE ACCOMPLISHMENT OF OTHER WORK. WHERE APPLICABLE, MASONRY WORK SHALL MATCH EXISTING WORK. FINISH BRICK WORK SHALL BE NEATLY TOOTHED INTO EXISTING MASONRY IF APPLICABLE. A. STRUCTURAL STEEL: REFER TO STRUCTURAL DRAWINGS (WHERE APPLICABLE.) B. METAL STUDS: COLD-FORMED GALVANIZED STEEL STUDS SIZED AS INDICATED ON DRAWINGS, WHICH CONFORM TO ASTM C955 & C1007 . INCLUDE ALL ACCESSORIES, SUCH AS BRIDGING, TRACK, ETC. PROVIDE ALL MISCELLANEOUS BOLTS, CLIPS, ANCHORS, ANGLES, BRACKETS, SLEEVES, FASTENERS, AND OTHER METAL ITEMS AS REQUIRED. WOOD STUDS MAY BE SUBSTITUTED WHERE PERMISSIBLE BY CODES. 1. COLD FORMED STEEL FRAMING SHALL CONFORM TO REQUIREMENTS OF THE LATEST EDITION OF ANSI "SPECIFICATION FOR DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS" 2. STUDS SHALL BE INSTALLED SO THE ENDS ARE POSITIONED AGAINST THE INSIDE OF THE RUNNER TRACK WEB PRIOR TO FASTENING AND SHALL BE ATTACHED TO BOTH FLANGES OF THE UPPER AND LOWER RUNNER TRACKS. 3. FOR VERTICAL STUDS WHERE THERE IS NO SHEATHING ATTACHED (SUCH AS ABOVE THE CEILING,) OR WHERE SHEATHING IS ATTACHED TO ONLY ONE FACE, PROVIDE STANDARD BRIDGING AT 48" O.C. MAX. ATTACH PER MANUFACTURER'S SPECIFICATIONS. STEEL, C. DECORATIVE METALS: INSTALL OWNER PROVIDED DECORATIVE METAL SUCH AS STAINLESS PREFINISHED METAL, ETC. AS INDICATED ON DRAWINGS, PER MANUFACTURER'S RECOMMENDATIONS. D. OWNER SUPPLIED METALS: G.C. IS RESPONSIBLE TO CONTACT VENDOR FOR ORDERING OF PREFINISHED METAL STOREFRONT PANELS, CORNER GUARDS AT TILE FACED COLUMNS. REFER TO INDIVIDUAL DETAILS FOR APPLICATION AND INSTRUCTIONS. E. MISCELLANEOUS METALS: PROVIDE METAL SHAPES AND FABRICATIONS AS REQUIRED AND NOT INCLUDED AS PART OF OTHER SECTIONS, WITH ANCHORS AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. SUBMIT SHOP DRAWINGS FOR CUSTOM DATA, PRODUCT DATA FOR MANUFACTURED ITEMS AND TEMPLATES FOR ANCHOR INSTALLATION BY OTHERS. STEEL SHAPES TO BE ASTM A36 STEEL. A. PROVIDE NEW LUMBER, BEARING GRADE AND TRADEMARK OF ASSOCIATION UNDER WHICH IT WAS PRODUCED. B. LAYOUT, CUT, FIT AND ERECT FRAMING FOR ROUGH AND FINISHED WORK. INSTALL BLOCKING, NAILERS, FURRING AND OTHER ROUGH AND FINISHED MATERIALS AS REQUIRED. BRACE, PLUMB LEVEL MEMBERS IN TRUE ALIGNMENT AND RIGIDLY SECURE IN PLACE WITH SUFFICIENT NAILS, SCREWS AND BOLTS AS NECESSARY. C. USE FIRE RETARDANT LUMBER AND TRIM WHERE REQUIRED BY STATE OR LOCAL CODES, WHICH BEAR THE MANUFACTURER'S STAMP OF AUTHENTICITY. D. FURNISH AND INSTALL ALL GROUNDS OR BLOCKING REQUIRED TO RECEIVE STORE FIXTURES OR OTHER WALL HUNG ELEMENTS, IF SHOWN ON DRAWINGS. E. FURNISH AND INSTALL ALL ROUGH HARDWARE, ANCHORS, BOLTS, ETC., AS REQUIRED FOR CARPENTRY WORK. F. FINISH CARPENTRY: CONFORM TO ARCHITECTURAL WOODWORK INSTITUTE (AWI) QUALITY STANDARDS OR WOODWORK INSTITUTE OF CALIFORNIA (WIC) "MANUAL OF MILLWORK" STANDARDS. PROVIDE PRIMED WOOD WALL BASE - COPE ALL CORNERS, MITER ALL OUTSIDE CORNERS, COUNTER SINK AND PUTTY ALL NAIL HOLES AND SAND SMOOTH. 13. a. OVERALL WIDTH (FACE OF GYPSUM BOARD ON DEMISING WALL TO FACE OF GYPSUM BOARD ON DEMISING WALL). OVERALL LENGTH (LEASE LINE TO INNER-FACE OF GYPSUM BOARD ON REAR WALL.) ANY AND ALL COLUMN LOCATIONS - FREE STANDING OR PROJECTING. AVAILABLE CLEAR HEIGHT FOR GRILLE AND CEILING AS DIMENSIONED ON DRAWINGS. b. c. d. A A. THE CONTRACTOR IS RESPONSIBLE TO DETERMINE IF A NEW CONCRETE SLAB IS REQUIRED IN ALL OR PART OF THE LEASED SPACE. SUCH FLOOR SLAB SHALL BE INSTALLED IN ACCORDANCE WITH ALL REQUIREMENTS, LOCAL CODES, OR COMMON STANDARDS OF PRACTICE TO THE LOCALITY OF THE PROJECT OR WHICHEVER IS STRICTER. IN THE ABSENCE OF THE ABOVE, THE CONTRACTOR SHALL CONTACT THE OWNER FOR DIRECTION. MINIMUM REQUIREMENTS FOR THE FLOOR SLABS ON GRADE 1 2 3 4 5 9 10 11 12 6 7 13 14 (3) E. 1. F. 1. EDGE SEALING: IMMEDIATELY AFTER CUTTING THE FINAL SIZES, AND APPLYING EDGE TREATMENT; FACTORY SEAL EDGES OF MIRRORS WITH EDGE SEALER TO PREVENT CHEMICAL OR ATMOSPHERIC PENETRATION OF GLASS COATING. 6. MISCELLANEOUS MATERIALS a. SETTING BLOCK: NON-RUBBER OR NON-NEOPRENE BASED ELASTOMERIC MATERIAL MANUFACTURED FOR SETTING SILVERED FLAT GLASS MIRRORS, COMPATIBLE WITH ADHESIVE USED FOR PLACEMENT, WITH A TYPE A SHORE DUROMETER HARDNESS OF 85, PLUS OR MINUS 5. 1/8" WIDE X 1/4" HIGH X 4" LONG. b. EDGE SEALER: COATING COMPATIBLE WITH GLASS COATING AND APPROVED BY MIRROR MANUFACTURER FOR USE IN PROTECTING AGAINST SILVER DETERIORATION AT MIRROR EDGES. c. MIRROR MASTIC: PALMER PRODUCTS CORP., "MIRROR-MASTIC", (502) 893-3668, (800) 431-6151, FAX (502) 895-9253. d. DRYWALL AND PLYWOOD PAINT (POROUS SUBSTRATE PRIMER): PALMER PRODUCTS CORP. "MIRROR-MASTIC BOND", (502) 893-3668, (800) 431-6151, FAX (502) 895-9253. : GENERAL CONTRACTOR TO CONTACT LANDLORD'S ON-SITE MANAGER FOR SPECIFICATIONS ON ROOF PATCHING OR NAME OF ROOFING CONTRACTOR TO CONTACT FOR REPAIRS. : GENERAL CONTRACTOR TO PROVIDE AND INSTALL RIGID AND/OR FULL BATT INSULATION AND 4 MIL POLYETHELENE (VISQUEEN) VAPOR RETARDER AT WALLS AND CEILING AS REQUIRED BY LANDLORD AND CONSTRUCTION DRAWINGS. C. 1. GENERAL: PROVIDE EXTERIOR AND INTERIOR JOINT SEALERS NOT PROVIDED ELSEWHERE; TYPE SUITABLE FOR APPLICATION INDICATED WITH ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. 2. INSTALLER QUALIFICATIONS: FIRM WITH MINIMUM FIVE YEAR'S SUCCESSFUL EXPERIENCE ON PROJECTS OF SIMILAR TYPE AND SIZE, USING SPECIFIED PRODUCTS. 3. WARRANTY: REPAIR OR REPLACE JOINT SEALERS WHICH FAIL TO PERFORM AS INTENDED, BECAUSE OF LEAKING, CRUMBLING, HARDENING, SHRINKAGE, BLEEDING, SAGGING, STAINING OR LOSS OF ADHESION; WARRANTY PERIOD TWO YEARS. 4. EXTERIOR NON-TRAFFIC JOINTS: GE/SILPRUF, DOW/790-795 OR PECORA/854, LOW MODULES SILICONE SEALANT. 5. TRAFFIC BEARING JOINTS: MAMECO/VULKEM 245 OR PECORA/NR-200 UREXPAN, MULTI-COMPONENT POLYURETHANE, SELF-LEVELING JOINT SEALER. 6. MILDEW-RESISTANT SANITARY SEALANTS: GE/SANITARY SEALANT, DOW/BATHTUB CAULK, OR PECORA/863 #345 WHITE; PROVIDE AT INTERIOR AREAS WHERE SEALANT WILL BE EXPOSED TO WATER. 7. GENERAL INTERIOR JOINT SEALER: PECORA/AC-20 OR SONNEBORN/SONOLAC, ACRYLIC OR LATEX EMULSION. MISCELLANEOUS MATERIALS: PRIMERS, SEALERS, JOINT CLEANERS, BOND BREAKER TAPE 8. AND SEALANT BACKER RODS AS RECOMMENDED BY SEALANT MANUFACTURER FOR APPLICATIONS INDICATED. a. OVERSIZE BACKER ROD MINIMUM 30 % TO 50 %%% OF JOINT OPENING. 9. COLORS: AS INDICATED OR SELECTED BY OWNER'S PROJECT MANAGER FROM MANUFACTURER'S FULL RANGE OF COLORS. 10. PREPARATION: CLEAN JOINT SURFACES IMMEDIATELY BEFORE INSTALLATION OF JOINT SEALER AND PRIME OR SEAL JOINT SURFACES AS RECOMMENDED BY MANUFACTURER. 11. INSTALLATION: COMPLY WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS AND ASTM C1193. b. EMPLOY INSTALLATION TECHNIQUES WHICH WILL ENSURE JOINT SEALERS ARE DEPOSITED IN UNIFORM, CONTINUOUS RIBBONS WITHOUT GAPS OR AIR POCKETS, WITH COMPLETE "WETTING" OF BOND SURFACES. e. D. 1. 2. NEW CONSTRUCTION - GENERAL CONTRACTOR TO FURNISH AND INSTALL 48" WIDE REFLECTIVE BUBBLE INSULATION MADE WITH TWO LAYER REFLECTIVE METALIZED ALUMINUM SEPARATED BY A 5/16" ENCLOSED AIR SPACE. INSTALL PER MANUFACTURERS SPECIFICATIONS. EXISTING CONSTRUCTION - GENERAL CONTRACTOR TO FURNISH AND INSTALL 24" WIDE .024 WHITE ALUMINUM TRIM COIL. INSTALL PER MANUFACTURERS SPECIFICATIONS. E. 7. WEATHER BARRIER MEMBRANE (DUPONT TYVEK COMMERCIALWRAP) MANUFACTURER: DUPONT; 4417 LANCASTER PIKE, CHESTNUT RUN PLAZA 728, WILMINGTON, DE 19805; 1-800-44-TYVEK (8-9835); INSTALLATION SHALL BE IN ACCORDANCE WITH WEATHER BARRIER MANUFACTURER'S INSTALLATION GUIDELINES AND RECOMMENDATIONS. SECURE USING WEATHER BARRIER MANUFACTURER RECOMMENDED FASTENERS, SPACE 12-18 INCHES VERTICALLY ON CENTER ALONG STUD LINE, AND 24 INCHES ON CENTER, MAXIMUM HORIZONTALLY. 8. : 1. DOOR HARDWARE: REFER TO DOOR SCHEDULE FOR HARDWARE SPECIFICATIONS. 2. HOLLOW METAL FRAMES: K.D. MINIMUM 16 GAUGE. SIZE AND SHAPE PER DOOR SCHEDULE. 3. LABELED DOORS: WHERE REQUIRED, PROVIDE U.L. LABEL DOORS AND FRAMES PER APPLICABLE STATE AND LOCAL BUILDING CODES. LABEL DOORS TO RECEIVE DOOR CLOSER. 4. FABRICATE AND ERECT TRUE, PLUMB AND SQUARE AS SPECIFIED AND AS DETAILED AND PER MANUFACTURER'S RECOMMENDATIONS. B. : 1. GLASS a. STOREFRONT GLASS TO BE HORIZONTALLY TEMPERED. SIZE AND NUMBER OF PIECES AS SHOWN ON DRAWINGS. GLAZING CONTRACTOR TO PROVIDE AND INSTALL ALL GLAZING CHANNELS, GASKETS, BLOCKING, ETC., REQUIRED FOR COMPLETE INSTALLATION. PROVIDE NEAT, UNIFORM (1/4" WIDE UNLESS NOTED OTHERWISE) GAPS BETWEEN GLASS PANES AND BETWEEN PANES AND ADJACENT VERTICAL SURFACES. b. ARRISSED EDGE: EDGES TO BE DIAMOND GROUND 1/16" 45 DEGREE BEVEL AT FRONT AND BACK FACES WITH ALL EXPOSED EDGES UNIFORMLY MACHINE POLISHED. c. OWNER REQUIRES THAT STOREFRONT GLASS NOT BOW MORE THAN +/- 1/16" OUT OF VERTICAL. d. ALL GLASS TO BE SET IN GLAZING GASKETS THE SIZE AND SHAPE NECESSARY TO ACCOMPLISH GOOD WORKMANSHIP. CAULKING NOT PERMITTED. C. : 1. QUALITY ASSURANCE a. INSTALLER QUALIFICATIONS: AN EXPERIENCED INSTALLER WHO HAS COMPLETED MIRROR GLAZING SIMILAR IN MATERIAL, DESIGN, AND EXTENT TO THAT INDICATED; WHOSE WORK HAS RESULTED IN MIRROR INSTALLATIONS WITH A RECORD OF NOT LESS THAN 5 YEARS OF SUCCESSFUL IN-SERVICE PERFORMANCE. b. SOURCE LIMITATIONS FOR MIRRORS: OBTAIN MIRRORS FROM ONE SUPPLIER/MANUFACTURER FOR EACH TYPE OF MIRROR INDICATED. c. SOURCE LIMITATIONS FOR GLAZING ACCESSORIES: OBTAIN GLAZING ACCESSORIES FROM ONE SOURCE FOR EACH TYPE OF ACCESSORY INDICATED. d. GLAZING PUBLICATIONS: COMPLY WITH THE APPLICABLE RECOMMENDATIONS OF THE FOLLOWING. WHERE RECOMMENDATIONS CONFLICT THE MORE STRINGENT SHALL APPLY. e. GLASS ASSOCIATION OF NORTH AMERICA (GANA): "GLAZING MANUAL" AND THE MIRROR DIVISION'S "MIRRORS, HANDLE WITH EXTREME CARE: TIPS FOR THE PROFESSIONAL ON THE CARE AND HANDLING OF MIRRORS." f. NATIONAL GLASS ASSOCIATION (NGA): "CUSTOM MIRRORS, FABRICATION AND INSTALLATION. 2. DELIVERY, STORAGE, AND HANDLING. a. PROTECT MIRRORS ACCORDING TO MIRROR MANUFACTURER'S WRITTEN INSTRUCTIONS AND AS NEEDED TO PREVENT DAMAGE TO MIRRORS FROM CONDENSATION, TEMPERATURE CHANGES DIRECT EXPOSURE TO SUN, OR OTHER CAUSES. b. COMPLY WITH MIRROR MANUFACTURER'S WRITTEN INSTRUCTIONS FOR SHIPPING, STORING, AND HANDLING MIRRORS AS NEEDED TO PREVENT DETERIORATION OF SILVERING, DAMAGE TO EDGES, AND ABRASION OF GLASS SURFACES AND APPLIED COATINGS. STORE INDOORS, PROTECTED FROM MOISTURE INCLUDING CONDENSATION. 3. PROJECTION CONDITIONS: ENVIRONMENTAL LIMITATIONS - DO NOT INSTALL MIRRORED GLASS UNTIL AMBIENT TEMPERATURE AND HUMIDITY CONDITIONS ARE MAINTAINED AT LEVELS INDICATED FOR FINAL OCCUPANCY. 4. SILVERED FLAT GLASS MIRROR MATERIAL: 6.0 MM THICK AND COMPLYING WITH ASTM C 1503, MIRROR SELECT QUALITY FOR USE IN VISUALLY DEMANDING APPLICATIONS REQUIRING MINIMAL DISTORTIONS AND BLEMISHES. 5. FABRICATION a. CUTOUTS: FABRICATE CUTOUTS FOR NOTCHES AND HOLES IN MIRRORS WITHOUT MARRING VISIBLE SURFACES. LOCATE AND SIZE CUTOUTS SO THEY FIT CLOSELY AROUND PENETRATIONS IN MIRRORS. b. MIRROR EDGE TREATMENT: CUTTING AND POLISHING (1) TYPICAL MIRRORS: FLAT EDGES WHERE THE CLEAN CUT "SQUARE" EDGE OF THE GLASS IS FLAT AND SURFACES EDGES ARE SLIGHTLY ARRISSED. AFTER GRINDING THE ARISSES, EDGES SHALL BE POLISHED TO A HIGH GLOSS SURFACE WHERE THE SURFACE REFLECTIVITY IS SIMILAR IN APPEARANCE TO THE MAJOR SURFACE OF THE GLASS. (2) BEVELED EDGED MIRRORS: PROVIDE BEVELED EDGED MIRRORS WHERE THE SURFACE EDGE OF THE GLASS IS BEVELED TO WIDTH INDICATED ON THE OWNER FURNISHED DRAWINGS. THE ANGLE FORMED BY THE INTERSECTION OF THE PLANCE OF THE BEVEL WITH THE MAJOR SURFACE FACE OF THE GLASS SHALL BE BETWEEN 3 TO 10 DEGREES. THE BEVELED SURFACE AND THE NOSE OF THE BEVEL SHALL BE POLISHED TO A HIGH GLOSS SURFACE WHERE THE SURFACE REFLECTIVITY IS SIMILAR IN APPEARANCE TO THE MAJOR SURFACE OF THE GLASS. 8 9 10 TOP AND BOTTOM ALUMINUM J CHANNELS: ALUMINUM EXTRUSIONS WITH A RETURN DEEP ENOUGH TO PRODUCE A GLAZING CHANNEL TO ACCOMMODATE 6 MM THICK MIRRORS AND HEAVY BODIED MIRROR MASTIC SPECIFIED AND IN A SINGLE PIECE. THE ENDS OF THE BACK LIPS OF ALL CHANNELS SHALL BE FACTORY SNIPPED AND FILED SO THAT THEY WILL NOT BE SEEN AFTER INSTALLATION. (1) BOTTOM AND SIDE TRIM: C.R. LAURENCE CO. INC., 1/4" STANDARD "J" CHANNEL (CATALOG NUMBER D636P POLISHED FINISH), (800) 421-6144, FAX (800) 262-3299. J-CHANNELS FORMED WITH FRONT LEG AND BACK LEG NOT LESS THAN 3/8" AND 7/8" IN HEIGHT, RESPECTIVELY. D. 1. 2. 4. 5. TOP TRIM: C.R. LAURENCE CO. INC., 1/4" DEEP NOSE "J" CHANNEL (CATALOG NUMBER D645P POLISHED FINISH), (800) 421-6144, FAX (800) 262-3299. J-CHANNELS FORMED WITH FRONT LEG AND BACK LEG NOT LESS THAN 5/8" AND 1-3/16" IN HEIGHT, RESPECTIVELY. f. STUD FASTENERS: PROVIDE #6 GAGE DIAMETER, 1-5/8" LONG, PHILLIPS BUGLE HEAD, SELF-DRILLING TYPE, FINE THREADED STEEL SCREW FASTENERS IN QUANTITY AS REQUIRED FOR SUPPORT AND FASTENING OF WOOD TRIMS AND MIRRORS CHANNELS TO DRYWALL STUD FRAMING AND SHEET METAL BACKER PLATES. HILTI KWI-PRO SELF DRILL DRYWALL SCREWS, ORDERING NAME: 6" X 1'-5/8" PBH SD, ITEM #: 00086216; HILTI CORPORATION (800) 879-8000. g. PLASTIC WOOD FILLER: COMMERCIAL QUALITY WOOD FILLER SPECIFICALLY MANUFACTURED TO ADVANCE THE FINAL BUILD AND SMOOTHNESS OF THE INSTALLED WOOD TRIM SURFACE BY FILLING DENTS, SCRATCHES, MITER JOINTS, AND VOIDS ABOVE COUNTERSUNK FASTENER HEADS. THE SELECTED FILLER SHALL BE EITHER NEUTRAL OR TINTED TO MATCH THE COLOR OF THE WOOD TRIM. h. PLYWOOD FASTENERS: PROVIDE MINIMUM #6 GAGE DIAMETER, PHILLIPS FLAT HEAD, SHARP POINTED, COARSE THREADED, STEEL WOOD SCREW FASTENERS IN QUANTITY AS REQUIRED. FURNISH PLYWOOD FASTENERS IN LENGTH AS REQUIRED TO SPAN THROUGH WOOD MIRROR TRIM, AND MIRROR CHANNELS, PLUS 3/4" i. WOOD MIRROR TRIM EXAMINATION a. EXAMINE SUBSTRATES, OVER WHICH MIRRORS ARE TO BE MOUNTED, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH INSTALLATION TOLERANCES, SUBSTRATE PREPARATION, AND OTHER CONDITIONS AFFECTING PERFORMANCE. (1) VERIFY COMPATIBILITY AND SUITABILITY OF SUBSTRATES, INCLUDING COMPATIBILITY OF MIRROR MASTIC WITH EXISTING FINISHES OR PRIMERS. PROCEED WITH MIRRORED GLASS INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED AND SURFACES ARE DRY. PREPARATION a. COMPLY WITH MASTIC MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS FOR PREPARATION OF SUBSTRATES. (1) MIRROR, DRYWALL AND PLYWOOD SUBSTRATES SHALL BE FREE OF DUST, BE CLEAN, AND DRY PRIOR TO APPLICATION OF MIRROR MASTIC AND DRYWALL AND PLYWOOD PAINT. IF PLYWOOD OR DRYWALL SURFACES HAVE BEEN PAINTED PRIOR TO APPLICATION OF THE SPECIFIED DRYWALL AND PLYWOOD PAINT THE EXISTING PAINT SHALL BE SANDED THROUGH THE ORIGINAL SURFACE AND THE SUBSTRATE CLEANED PRIOR TO THE APPLICATION OF DRYWALL AND PLYWOOD PAINT. : GENERAL: INSTALL MIRRORS WITH MIRROR GLAZING CHANNELS TO COMPLY WITH WRITTEN INSTRUCTION OF MIRROR AND MIRROR GLAZING CHANNEL MANUFACTURERS, WITH REFERENCED GANA AND NGA PUBLICATIONS, OWNER FURNISHED DRAWINGS, AND AS SPECIFIED. MOUNT MIRRORS PLUMB, IN LINE AND IN A MANNER THAT AVOIDS DISTORTING REFLECTED IMAGES MIRROR CHANNEL INSTALLATION: a. TO PLYWOOD: DRILL, DO NOT DIMPLE, BACK LIP OF CHANNEL TO RECEIVE FASTENERS WITH HOLES PROPERLY SIZED AND SPACED TO RECEIVE FASTENERS. ATTACH MIRROR CHANNELS BY SCREW ATTACHING MIRROR CHANNEL THROUGH THE BACK LIP OF THE CHANNEL TO PLYWOOD SUBSTRATE IN ACCORDANCE WITH THE FASTENER MANUFACTURERS WRITTEN INSTRUCTIONS. INSTALL THE WEB OF THE TOP CHANNEL 1/4" HIGHER THAN THE HEIGHT OF THE MIRROR TO ALLOW THE RAISING OF THE MIRROR IN TO THE TOP CHANNEL AND ITS SUBSEQUENT LOWERING INTO THE BOTTOM CHANNEL. AFTER INSTALLING FASTENERS PLACE MASKING TAPE OVER THE ENTIRE LENGTH OF THE BACK LIP OF THE CHANNEL COMPLETELY COVERING THE FASTENER HEADS TO PROTECT THE MIRROR FROM BEING CHIPPED IN SETTING. ADHERE SETTING BLOCKS AT QUARTER POINTS FOR BOTTOM MIRROR CHANNELS USING ONLY 2 SETTING BLOCKS PER MIRROR PANEL. b. TO DRYWALL: MARK THE LOCATIONS FOR THE STUD FASTENERS ON THE BACK LIP OF EACH MIRROR CHANNEL AT EQUAL INTERVALS NOT OVER 8" ON CENTER, AND NOT MORE THAN 3" FROM ENDS PRIOR TO DRILLING THE CHANNEL. DRILL AND COUNTERSINK, DO NOT DIMPLE BACK LIP OF CHANNEL TO RECEIVE STUD FASTENERS AT MARKED LOCATIONS WITH HOLES PROPERLY SIZED TO RECEIVE STUD FASTENERS. ATTACH MIRROR CHANNELS BY SCREW ATTACHING MIRROR CHANNEL THROUGH THE BACK LIP OF THE CHANNEL THROUGH DRYWALL, STUD FRAMING AND SHEET METAL BACKER PLATE SUBSTRATES IN ACCORDANCE WITH THE FASTENERS MANUFACTURERS WRITTEN INSTRUCTIONS. (1) INSTALL THE WEB OF THE TOP CHANNEL 1/4" HIGHER THAN THE HEIGHT OF THE MIRROR TO ALLOW THE RAISING OF THE MIRROR INTO THE TOP CHANNEL AND ITS SUBSEQUENT LOWERING ONTO THE WEB OF THE BOTTOM CHANNEL. AFTER INSTALLING FASTENERS PLACE MASKING TAPE OVER THE ENTIRE LENGTH OF THE BACK LIP OF THE CHANNEL COMPLETELY COVERING THE FASTENER HEADS TO PROTECT THE MIRROR FROM BEING CHIPPED IN SETTING. ADHERE SETTING BLOCKS TO THE WEB OF THE BOTTOM MIRROR CHANNELS, LOCATED AT QUARTER POINTS, USING 2 SETTING BLOCKS PER MIRROR PANEL. WOOD TRIM & INSTALLATION a. BEFORE INSTALLING MIRROR WOOD TRIM, EXAMINE SHOP-FABRICATED WORK FOR COMPLETION AND COMPLETE WORK AS REQUIRED. PRIME TO ALL EXPOSED SURFACES OF THE MIRROR WOOD TRIM WHICH WILL BE IN CONTACT WITH THE MIRROR BACKING TO ELIMINATE INTERACTIONS BETWEEN THE RESINS IN THE WOOD AND THE MIRROR BACKING. b. INSTALL MIRROR WOOD TRIM PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. SCRIBE AND CUT MIRROR WOOD TRIM TO FIT ADJOINING WORK, AND REFINSH CUT SURFACES AND REPAIR DAMAGED FINISH AT CUTS. INSTALL WITH MINIMUM NUMBER OF JOINTS POSSIBLE, USING FULL-LENGTH PIECES (FROM MAXIMUM LENGTH OF WOOD TRIM AVAILABLE) TO GREATEST EXTENT POSSIBLE. DO NOT USE PIECES LESS THAN 16" LONG, EXCEPT WHERE SHORTER SINGLE-LENGTH PIECES ARE NECESSARY. SCARF RUNNING JOINTS. MITERS OVER 4" LONG SHALL BE SPLINED AND GLUED. PROTECTION AND CLEANING a. PROTECT MIRRORS FROM BREAKAGE AND CONTAMINATING SUBSTANCES RESULTING FROM CONSTRUCTION OPERATIONS. USING CLEAN WARM WATER, CLEAN MIRRORS BY METHODS RECOMMENDED IN REFERENCED GLAZING STANDARDS. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150066 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect SEAL (2) A. 4.5 X 118.932 = 8.3 64.5 POUNDS PER 1,000 SQUARE FEET IN 24 HOURS WEIGHT GAIN X 118.932 = WITHIN FIVE (5) DAYS OF COMMENCEMENT OF CONSTRUCTION, OR WITHIN TWO (2) DAYS FOLLOWING COMPLETION OF DEMOLITION, THE CONTRACTOR SHALL CAREFULLY EXAMINE THE SITE AND REPORT TO THE OWNER'S CONSTRUCTION MANAGER ANY DISCREPANCIES IN THE LEASE-HOLD DIMENSIONS OR CONFLICTS BETWEEN THE PHYSICAL SPACE AND THE INTENT OF THE WORKING DRAWINGS (G.C. TO PAY SPECIAL ATTENTION TO POP-UP CEILING AREAS, CEILING HEIGHTS, AND AVAILABLE HEIGHT FOR ROLL-UP ENTRANCE GRILLES). GENERAL CONTRACTOR IS TO CONTACT LANDLORD'S ON-SITE MANAGER PRIOR TO ANY DEMOLITION WORK TO DETERMINE THE AVAILABILITY OF DUMPSTER PLACEMENT, NOISE AND DUST ABATEMENT REQUIREMENTS, ETC. GENERAL CONTRACTOR IS TO ARRANGE WITH THE LANDLORD A CONVENIENT TIME TO PERFORM DEMOLITION WORK AND INSTALL TEMPORARY PROTECTED MEANS OF EGRESS FROM REQUIRED EXITS, INCLUDING TEMPORARY LIGHTING AND SAFETY DEVICES, ALL IN ACCORDANCE WITH GOVERNING STATE AND LOCAL CODE AND LANDLORD REQUIREMENTS. GENERAL CONTRACTOR TO ERECT BARRICADE AT STOREFRONT PER LANDLORD'S SPECIFICATIONS. GENERAL CONTRACTOR TO INSTALL OWNER SUPPLIED BARRICADE SIGN (IF PROVIDED) AS SHOWN ON INSTRUCTIONS SENT WITH BID PACKAGES. THE GENERAL CONTRACTOR SHALL REMOVE, REPAIR, RESTORE AND REPLACE WHERE NECESSARY OR INDICATED ON THE DRAWINGS OR AS REQUIRED. CUT ALL NECESSARY OPENINGS FOR ANY REQUIRED PURPOSE AND REPAIR, WHERE NECESSARY, AFTER CUTTING. INSOFAR AS POSSIBLE, ALL PROTRUSIONS, MARKS, CRACKS OR OTHER EVIDENCE OF A DEFICIENT OR DAMAGED CONDITION SHALL BE ELIMINATED UNLESS SPECIFICALLY NOTED OTHERWISE. ANY PARTS WHICH ARE SPLIT, CRACKED, CHIPPED, SPALLED, BROKEN, MISSING, OR OUT OF LINE OR ADJUSTMENT, MECHANICALLY OR STRUCTURALLY UNSAFE OR UNSOUND, BENT, TORN, OR OTHERWISE DEFICIENT OR INJURED IN ANY MANNER, SHALL BE REMOVED, REPLACED, RESTORED, OR SATISFACTORILY REPAIRED AS DIRECTED BY THE OWNER'S CONSTRUCTION MANAGER. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL LEASE-HOLD IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO: INTERIOR WALLS, CEILINGS, FLOOR COVERINGS (ALL ADHESIVES), PLATFORMS, STORE-FRONTS, ETC. (UNLESS INDICATED OTHERWISE ON ARCHITECTURAL DRAWINGS). ALL EXISTING UNUSED MECHANICAL, ELECTRICAL AND/OR PLUMBING FIXTURES AND EQUIPMENT, INCLUDING ABANDONED ROOFTOP HVAC EQUIPMENT AND CURBS (UNLESS INDICATED OTHERWISE ON MECHANICAL AND ELECTRICAL DRAWINGS) AND/OR SKYLIGHTS ARE TO BE REMOVED AND THE ROOF PATCHED PER ITEM #12 BELOW: CAPPING IS PERMITTED! GENERAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL LOOSE ITEMS SUCH AS, BUT NOT LIMITED TO: TRADE FIXTURES, MISCELLANEOUS DECORATIONS, KITCHEN EQUIPMENT, ETC. ALL ABANDONED ELECTRICAL/TELEPHONE CONDUIT, PLUMBING LINES AND MECHANICAL DUCTWORK MUST BE REMOVED TO THE POINT OF ORIGIN. INFORM THE LANDLORD'S ON-SITE MANAGER OF ANY UTILITY NEEDING TO BE DISCONNECTED OR CAPPED, PRIOR TO DOING SO. GENERAL CONTRACTOR IS TO EXERCISE EXTREME CARE DURING DEMOLITION SO AS NOT TO DAMAGE OR DISRUPT UTILITIES OR SPRINKLER LINES WHICH MIGHT PASS THROUGH THIS SPACE TO SERVICE OTHER MALL SPACES OR OTHER TENANTS (G.C. WILL BEAR SOLE RESPONSIBILITY FOR ANY SUCH DAMAGE OR DISRUPTION). GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK AND MUST INFORM OWNER'S CONSTRUCTION MANAGER OF THE EXTENT OF SUCH WORK, PRIOR TO BIDDING. GENERAL CONTRACTOR IS TO DETERMINE HIS RESPONSIBILITY FOR THE FLOOR SLAB AND DEMISING WALL INSTALLATION OR MODIFICATIONS WITH LANDLORD AND OWNER'S CONSTRUCTION MANAGER TO MEET ALL TENANT IMPROVEMENT CRITERIA AND RESPONSIBILITY SET BY THE LANDLORD OR OWNER. GENERAL CONTRACTOR IS TO VERIFY THE ACTUAL CONDITION OF THE PERIMETER DEMISING WALLS AND/OR FLOOR SLAB PRIOR TO BIDDING. BID IS TO INCLUDE ALL WORK REQUIRED. 8 NUMERIC EXAMPLE W/ A 4.5 GAIN IN 64.5 HRS. (ALWAYS ROUND TO THE NEAREST TENTH): WEIGHT GAIN X 118.932 = POUNDS TOTAL HOURS A. 7 SHALL BE FOUR INCH THICK CONCRETE SLAB REINFORCED WITH 6"x 6"W.W.F.; CONCRETE TO BE 3,500 PSI OR HIGHER PLACED OVER COMPACTED SAND AGGREGATE BASE. PLACE 10 MIL VAPOR BARRIER AT THE MIDPOINT OF THE COMPACTED SAND/AGGREGATE BASE. THE SOIL SHALL BE INSECT TREATED IF CUSTOMARY TO THE LOCALITY OR AS REQUIRED BY LANDLORD. PROVIDE JOINT SEALANT IN ALL CONCRETE CONTROL JOINTS AS SPECIFIED IN DIVISION 7. PROVIDE JOINT FILLER STRIPS WHERE APPLICABLE: ASTM D-1751, CELLULOSE FIBER. VAPOR RETARDER, CLEAR 10 MIL POLYETHELENE SHEET. SLAB FINISHES 1. FLOAT FINISH FOR INTERIOR STEPS, RAMPS AND SURFACES TO RECEIVE WATER PROOFING OR OTHER DIRECT-APPLIED MATERIAL 2. TROWELED FINISH FOR FLOOR SURFACES AND FLOORS TO RECEIVE FLOOR COVERINGS, PAINT OR OTHER THIN FILM FINISH COATINGS. 3. TROWEL AND FINE BROOM FINISH FOR SURFACES TO RECEIVE THINSET TILE. 4. NON-SLIP BROOM FINISH FOR EXTERIOR CONCRETE PLATFORMS, STEPS AND RAMPS. ANHYDROUS CALCIUM CHLORIDE CONCRETE MOISTURE VAPOR EMISSION TEST KIT CONDUCTING THE MOISTURE TEST 1. : BEFORE YOU TEST, MAKE SURE YOU HAVE BASIC TOOLS FOR CLEANING THE SLAB, INCLUDING A SCRAPER AND WIRE BRUSH. MAKE SURE YOU HAVE A QUALITY GRAM SCALE AND A PROPER SUPPLY OF TEST KITS AND PROTECTIVE CONES. ENSURE BUILDING CLIMATE IS BETWEEN 65 & 85 DEGREES FAHRENHEIT WITH RELATIVE HUMIDITY % BETWEEN 40-60 FOR AT LEAST 48 HOURS PRIOR TO, AND DURING TESTING. 2. : THE SLAB MUST BE CLEAN OF DEBRIS AND ADHESIVE RESIDUE. SHOT BLAST SURFACE OR WIRE BRUSH SLAB CLEAN. REMOVE DUST THOROUGHLY. DO NOT USE CHEMICALS OF ANY KIND TO CLEAN THE FLOOR. AVOID TEST LOCATIONS NEAR CRACKS OR JOINTS, OR IN DIRECT SUNLIGHT. PREPARE 3 TEST SITES FOR THE FIRST 1,000 SQ. FT. AND INCLUDE 1 MORE TEST FOR EACH ADDITIONAL 1,000 SQUARE FEET OF AREA. 3. : READ THE WARNING LABEL ON PACKAGE AND THEN OPEN THE CONTAINER BAG. SET THE ENTIRE TAPE SEALED DISH ON THE GRAM SCALE AND RECORD ITS WEIGHT ON THE DISH LID AND ON THE TEST KIT BOOKLET. RECORD THE STARTING DATE AND TIME AS WELL. ENSURE THAT THE SAME SCALE WILL BE AVAILABLE FOR RE-WEIGHING THE DISH, OR THE VALIDITY OF THIS TEST WILL BE COMPROMISED. 4. : REMOVE THE BLUE VINYL TAPE FROM THE DISH. BE CAREFUL NOT TO LOSE THE TAPE AS YOU WILL NEED TO RESEAL THE DISH LATER. STORE THE DISH LID CAREFULLY AND STICK THE TAPE ALONG THE SIDE OF THE PLASTIC. DOME TO KEEP IT SAFE. SOME PEOPLE PREFER TO TAPE THE DISH'S LID TO THE INSIDE OF THE DOME WHERE IT CAN BE READ THROUGH THE TOP. DO NOT TOUCH OR SPILL THE CALCIUM CHLORIDE. 5. : PLACE THE OPEN DISH ON THE SLAB MAKING SURE THE CALCIUM CHLORIDE INSIDE IS FAIRLY LEVEL. DO NOT SET THE KIT DIRECTLY OVER A CONTROL JOINT OR CRACK. REMOVE THE WHITE PAPER ON THE DOME, AND CENTER THE DOME OVER THE DISH. THE ONLY MOISTURE ABSORBED BY THE CALCIUM CHLORIDE MUST BE WITHIN THE 70 SQUARE INCH AREA OF THE DOME THAT IS IN CONTACT WITH THE CONCRETE SLAB. 6. : USING THE HANDLE OF YOUR WIRE BRUSH OR OTHER TOOL, FIRMLY SQUASH THE GASKET UNDER THE FLANGES OF THE DOME. THE IDEAL INSTALLATION WILL SEAT THE OUTER FLANGE OF THE DOME TO THE SLAB. THEN THE GASKET MATERIAL WILL MOVE TO LINE UP WITH THE INSIDE EDGE OF THE DOME. PLACE YOUR HAND OVER THE DOME AND GENTLY APPLY PRESSURE. THERE SHOULD BE NO LEAKS IN THE GASKET. 7. : PLACE THE OPTIONAL SAFETY CONE OVER THE DOME AND LET THE TEST REMAIN UNDISTURBED FOR 60 TO 72 HOURS. MOST MANUFACTURERS OF FLOORING PRODUCTS RECOMMEND AT LEAST ONE KIT PER 1,000 SQUARE FEET. THE TEST ONLY MEASURES A SMALL AREA OF SLAB SURFACE AND MOISTURE LEVELS CAN VARY GREATLY OVER 1,000 SQ. FT. TEST SEVERAL AREAS WHENEVER POSSIBLE. 8. : AFTER 60 TO 72 HOURS, CUT OPEN THE DOME AND CAREFULLY RETRIEVE THE DISH. REPLACE THE LID AND SEAL IT BACK UP WITH THE BLUE TAPE. WEIGH THE DISH AGAIN ON THE SAME GRAM SCALE. RECORD THE ENDING WEIGHT, DATE, AND TIME ON THE DISH LID AS WELL AS ON THE TEST KIT BOOKLET. FOLLOW THE INSTRUCTIONS IN THIS BOOKLET TO COMPUTE THE MOISTURE VAPOR EMISSION RATE. CALCULATING RESULTS: USE THE FOLLOWING EQUATION TO DETERMINE THE VAPOR EMISSION VOLUME IN POUNDS PER 1,000 SQUARE FEET IN 24 HOURS. SEE FOOTNOTE. AT 2 RIVERCHASE GALLERIA 1 RIVERCHASE GALLERIA 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM SGH STORE #: 4933 DRAWN BY: PWD REVIEWED BY: RJH/JRM AUTHORIZED FOR: ARCHITECTURAL SPECIFICATIONS A-701 11 12 13 14 1. K 2. 3. 4. 5. 6. 7. 8. 9. J 10. 11. H 12. 13. G 3 4 : GENERAL: INSTALL OWNER SUPPLIED EXTRUDED ALUMINUM STOREFRONT AND ENTRANCE SYSTEM WITH DOORS, FRAMES, HARDWARE, AND ACCESSORIES AS REQUIRED FOR COMPLETE WEATHERTIGHT INSTALLATION. STANDARDS: COMPLY WITH ARCHITECTURAL ALUMINUM MANUFACTURERS ASSOCIATION (AAMA) "ALUMINUM STORE FRONT AND ENTRANCE MANUAL." CODES AND REGULATIONS: COMPLY WITH APPLICABLE CODES AND REGULATIONS. SUBMITTALS: NOT REQUIRED. INSTALLATION WARRANTY MANUFACTURER: OLD CASTLE OR EQUAL , AS APPROVED BY OWNER. STOREFRONT: EXTRUDED ALUMINUM ENTRANCE SYSTEM AS INDICATED ON DRAWINGS. a. ALUMINUM TYPE: AS RECOMMENDED BY MANUFACTURER FOR APPLICATION INDICATED, BUT NOT LESS THAN EXTRUDED ALUMINUM, ASTM B221, 6061 OR 6063 ALLOY AND T5 OR T6 TEMPER. FINISH: SEE DRAWINGS GLAZING: ASTM C1048, PROVIDE FULLY TEMPERED SELECT GLAZING QUALITY CLEAR FLOAT GLASS; NOMINAL 1/2" SAFETY GLASS UNLESS OTHERWISE INDICATED. a. APPLIED GLAZING FILM: SUPPLY & APPLY 3M FILM ON ALUMINUM FRAMED STOREFRONT GLASS WHERE INDICATED ON DRAWINGS. GLAZING ACCESSORIES: OF TYPE RECOMMENDED BY MANUFACTURER TO SUIT SECURITY LOCATIONS AND APPLICATIONS FOR DRY GLAZING INSTALLATION. MISCELLANEOUS MATERIALS: a. STEEL REINFORCEMENT AND BRACKETS: MANUFACTURER'S STANDARD WITH MINIMUM 2 OZ. HOT-DIP ZINC COATING, ASTM A123, APPLIED AFTER FABRICATION. b. BITUMINOUS PAINT: COLD-APPLIED MASTIC, SSPC PAINT 12, COMPOUNDED FOR 30 MIL THICKNESS PER COAT. c. FLASHING: INSTALL SUB-SILL FLASHING MEMBERS; MINIMUM 22 GAGE SHEET ALUMINUM OF SIZES AND SHAPES INDICATED AND AS REQUIRED TO DRAIN WATER TO EXTERIOR; MATCH ADJACENT ALUMINUM MEMBER FINISH. d. ANCHORING DEVICES: CORROSION RESISTANT TYPE CAPABLE OF SUPPORTING ENTRANCE SYSTEM AND SUPERIMPOSED DESIGN LOADS; DESIGN TO ALLOW ADJUSTMENTS OF SYSTEM PRIOR TO BEING PERMANENTLY FASTENED IN PLACE. FABRICATION: a. ACCURATELY FIT TOGETHER JOINTS AND CORNERS; MATCH COMPONENTS ENSURING CONTINUITY OF LINE AND DESIGN; ENSURE JOINTS AND CONNECTIONS ARE FLUSH, 1/64th INCH MAX. AND WEATHERPROOF. NO CAULK AT ANY JOINTS OR CONNECTIONS. NO EXCEPTIONS! b. SEPARATE DISSIMILAR MATERIALS WITH BITUMINOUS PAINT OR PREFORMED SEPARATORS WHICH WILL PREVENT CORROSION. INSTALLATION: INSTALL ALUMINUM FRAMED STOREFRONT ASSEMBLIES, INCLUDING ENTRANCES, IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND TO MEET DESIGN REQUIREMENTS INDICATED, FOR WEATHERTIGHT INSTALLATION. a. ENSURE ASSEMBLIES ARE PLUMB, LEVEL AND FREE OF WARP OR TWIST; MAINTAIN DIMENSIONAL TOLERANCES AND ALIGNMENT WITH ADJACENT WORK. b. USE SUFFICIENT ANCHORAGE DEVICES TO SECURELY AND RIGIDLY FASTEN ASSEMBLIES TO BUILDING. c. INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, USING PROPER TEMPLATES. COORDINATE INSTALLATION OF CYLINDERS WITH SECTION 08700. d. INSTALL SILL MEMBERS AND THRESHOLDS IN BED OF COMPOUND, JOINT FILLERS OR GASKETS TO PROVIDE WEATHERTIGHT CONSTRUCTION. e. GLASS INSTALLATION: COMPLY WITH GANA GLAZING MANUAL AND GLAZING MANUFACTURER INSTRUCTIONS. DO NOT ALLOW GLASS TO TOUCH METAL SURFACES. E. 1. 2. LAYOUT: A-702 P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\A-701_04933.dwg PLOTTED: 7/9/2015 - 8:47 AM USER: PDICKERSON : FURNISH AND INSTALL ALL GYPSUM DRYWALL AND SYSTEMS COMPLETE WITH PARTITION FRAMING, CEILING SUSPENSION SYSTEMS AND RELATED ACCESSORIES, PARTS, MATERIALS, ETC. AS SHOWN ON DRAWINGS AND AS SPECIFIED. INSTALL ALL MATERIALS PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 2. GYPSUM DRYWALL: U.S. GYPSUM 5/8" THICK FIRE CODE SHEETROCK (TYPE 'X') PANELS OF STANDARD QUALITY. GENERAL CONTRACTOR MAY USE NON-RATED 5/8" THICK BOARD IN AREAS OF STORE WHERE ALLOWED BY STATE AND LOCAL CODES. ALWAYS USE TYPE 'X' ON DEMISING WALLS. 3. FASTENERS: DRYWALL SCREWS OF PROPER SIZE AND TYPE, PER MANUFACTURER'S RECOMMENDATIONS. 4. METAL ACCESSORIES: U.S. GYPSUM OR GOLD BOND SYSTEM OF COMPONENTS AND JOINT TAPE. 5. JOINT TREATMENT: U.S. GYPSUM OR GOLD BOND SYSTEM OF COMPONENTS AND JOINT TAPE. 6. METAL FRAMING: WHERE NOT SHOWN AND SPECIFIED TO BE COLD-FORMED METAL FRAMING IN THE DRAWINGS, CONFORM TO ASTM C645 AND ASTM C754. 7. FINISHING: COMPLY WITH GYPSUM ASSOCIATION (GA) "LEVELS OF GYPSUM BOARD FINISH" - GA LEVEL 4, THREE COAT FINISHING AND SANDING IS REQUIRED FOR SURFACES INDICATED TO BE PAINTED, PROVIDE FLUSH, SMOOTH JOINTS AND SURFACES READY FOR APPLIED PAINT FINISHES. B. 1. C B : CERAMIC TILE AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. (IF APPLICABLE) INSTALL CERAMIC TILE USING RECOMMENDED METHODS OF THE TILE CONTRACTORS ASSOCIATION OF AMERICA AND THE TILE COUNCIL OF AMERICA, INC. 3. INSTALL CERAMIC TILE USING GROUT AND JOINT SPACING SPECIFIED IN FINISH SCHEDULE. 4. ADHESIVE IS TO BE PROVIDED AND INSTALLED BY GENERAL CONTRACTOR (PER MANUFACTURER'S SPECIFICATIONS). 5. CAREFULLY CLEAN ALL WORK AND REPLACE OR REPOINT ANY DAMAGED WORK AND LEAVE IN PERFECT CONDITION. USE NO ACID, AGENT OR DEVICE THAT WILL MAR SURFACE. CONSULT WITH OWNER'S CONSTRUCTION MANAGER FOR INSTRUCTIONS (DO NOT POLISH CERAMIC TILE). 6. CERAMIC TILES ARE TO BE SET WITHOUT TRIPPING HAZARD TO CUSTOMERS OR STAFF. 7. THE GENERAL CONTRACTOR IS RESPONSIBLE TO CORRECT RAISED CERAMIC TILES FOR THE ENTIRE DURATION OF THE WARRANTY PERIOD AT THE DIRECTION OF THE OWNER'S CONSTRUCTION MANAGER. 2. C. : 1. FURNISH AND INSTALL CEILING SYSTEM COMPLETE WITH SUSPENSION SYSTEM AND RELATED ACCESSORIES AS SHOWN ON DRAWINGS AND AS SPECIFIED. 2. SUSPENSION SYSTEMS SHALL BE ADEQUATE TO SUPPORT LIGHT FIXTURES, CEILING, GRILLES, DIFFUSERS AND OTHER NORMAL ACCESSORIES. PROVIDE SYSTEM COMPONENTS FROM A SINGLE MANUFACTURER. 3. INSTALL CEILING AND SUSPENSION SYSTEMS IN STRICT ACCORDANCE WITH ASTM C754, ASTM C635 AND ASTM C636. FINISH CEILING SHALL BE LEVEL, WITH JOINTS SNUG AND SQUARE, AND TILES OR PANELS IN PERFECT CONDITION. 4. MATERIALS AND FINISHES a. REFER TO DRAWINGS FOR LOCATION OF SPECIFIED MATERIALS AND FINISHES WHEN APPLICABLE. b. NON-SALES CEILING: AS SCHEDULED OR EQUAL. CLASS "A" RATING. c. WHEN A ONE-HOUR FIRE-RATED CEILING ASSEMBLY IS REQUIRED BY LANDLORD, STATE OR LOCAL CODES, THEN GENERAL CONTRACTOR IS TO CONFORM WITH UNDERWRITER'S LABORATORIES DESIGN FOR A ONE-HOUR RATED ASSEMBLY AS SCHEDULED. d. G.C. TO PROVIDE ONE BOX OF THE SPECIFIED CEILING TILES ON SITE FOR FUTURE USE. 5. SEISMIC ZONES: PROVIDE TO COMPLY WITH STATE AND LOCAL REQUIREMENTS FOR SEISMIC BRACING OF CEILING SUSPENSION SYSTEM, WITH ASTM E580 AND AS DETAILED ON DRAWINGS. COMPLY ALSO WITH AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE 7-02) AND CEILING AND INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION (CISCA) STANDARDS. CONSULT LOCAL CODES FOR MINIMUM CEILING AREA REQUIREMENTS. D. 1. A 2. : GENERAL: G.C. TO INSTALL OWNER SUPPLIED VINYL FLOORING SYSTEM WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. PROJECT CONDITIONS: PRIOR TO INSTALLATION OF ANY FLOORING, GC MUST ENSURE THAT THE JOBSITE AND SUB-FLOOR MEET THE REQUIREMENTS OF THE FOLLOWING INSTRUCTION. a. G.C. TO PERFORM MOISTURE TEST ON ALL CONCRETE FLOORS AS DIRECTED BY NWFA AND INSTALL BOSTIK MVP4 VAPOR BARRIER. MOISTURE CONTENT OF WOOD SUB-FLOOR MUST NOT EXCEED 12% AND CONCRETE MOISTURE CONTENT MUST NOT EXCEED 3LBS. b. G.C. TO PROVIDE MOISTURE TEST REPORT TO CONSTRUCTION MANAGER 1 2 3 7 : SEE FINISH SCHEDULE. BUTT BASE TO FLOOR AND WALL WITH NO GAPS. FILL ALL CRACKS, JOINTS, ETC. IN SUB-FLOOR WITH CRACK FILLER APPROVED BY FLOORING MANUFACTURER. INSTALL ALL MATERIALS WITH WATERPROOF TYPE ADHESIVES AS RECOMMENDED BY FLOORING MANUFACTURER FOR MATERIALS AND SURFACES INVOLVED. THIS SPECIFICATION DEFINES THE REQUIREMENTS FOR SURFACE PREPARATION, COATING SYSTEMS, MINIMUM AND MAXIMUM DRY FILM THICKNESS, SPECIAL APPLICATION INSTRUCTIONS WHEN NECESSARY AND INSPECTION FOR PAINTING OF SPECIFIED SUBSTRATES. 2. IF INSTRUCTIONS CONTAINED IN THIS SPECIFICATION, BID DOCUMENTS OR THE PAINTING SCHEDULE ARE AT VARIANCE WITH THE PAINT MANUFACTURER'S INSTRUCTIONS OR THE APPLICABLE STANDARDS AND CODES PUBLISHED BY SSPC OF OSHA, SURFACES SHALL BE PREPARED AND PAINT APPLIED TO MEET THE HIGHER STANDARD, AS DETERMINED BY THE DESIGN AUTHORITY. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REQUESTING PROMPT CLARIFICATION WHEN INSTRUCTIONS ARE LACKING, CONFLICTS OCCUR IN THE SPECIFICATION AND/OR PAINT MANUFACTURER'S LITERATURE, OR THE PROCEDURE SPECIFIED IS NOT CLEARLY UNDERSTOOD. IN THE EVENT, THE CONTRACTOR FAILS TO RESOLVE THE CONFLICTS, WHICH MAY EXIST, HE SHALL BE RESPONSIBLE FOR HANDLING THE DISCREPANCIES IN A MANNER AS PRESCRIBED BY THE DESIGN AUTHORITY AT NO ADDITIONAL COST TO THE OWNER. 4. ALL PERTINENT SAFETY REGULATIONS, BOTH THE OWNER'S AND OSHA'S SHALL BE ADHERED TO RIGIDLY. IN ADDITION, ALL SAFETY PRECAUTIONS NOTED ON THE MANUFACTURER'S PRODUCT DATA SHEETS AND LABELS SHALL BE OBSERVED FOR BOTH MATERIALS AND EQUIPMENT. 5. THE APPLICATION SHALL LEAVE NO SAGS, RUNS OR HOLIDAYS. ANY DAMAGE IN ANY COAT SHALL BE REPAIRED TO CONFORM TO THIS SPECIFICATION PRIOR TO FINAL INSPECTION. 6. WHERE REQUIRED, IMPERFECTIONS AND HOLES IN SURFACES TO BE COATED SHALL BE CLEANED AND REPAIRED ACCORDING TO HIGHEST INDUSTRY STANDARDS AND IN A MANNER APPROVED BY THE DESIGN AUTHORITY. 7. ALL MATERIALS SPECIFIED FROM BENJAMIN MOORE & CO., AND ARE INTENDED TO ESTABLISH STANDARDS OF QUALITY AND GENERIC TYPES. COATING SUBSTITUTIONS ARE PROHIBITED. 8. ALL COATING MATERIALS SHALL BE DELIVERED TO OTHER JOB SITE IN THE ORIGINAL AND UNOPENED CONTAINERS, PLAINLY MARKED WITH THE PROPER DESIGNATION OF THE PRODUCT, AS WELL AS THE NAME OF THE MANUFACTURER. ALL COATING MATERIALS AT THE JOB SITE SHALL BE SUBJECT TO INSPECTION BY THE OWNER'S REP. 9. ALL PAINTING MATERIALS SHALL BE STORED IN A CLEAN, DRY WELL VENTILATED PLACE, PROTECTED FROM SPARKS, FLAME, DIRECT RAYS OF THE SUN, AND EXCESSIVE HEAT OR COLD. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE PROTECTION AND SAFETY OF THE MATERIALS STORED BY G.C. AT THE JOB SITE. 10. PAINT ADDITIVES ARE PROHIBITED. 11. COLORS FOR INDIVIDUAL ITEMS SHALL BE AS SPECIFIED IN THE FINISH PAINTING SCHEDULE, OF THIS SPECIFICATION AND/OR THE PAINTING SCHEDULE SUBMITTED AS A PART OF THE SCOPE OF WORK DOCUMENTS WITH THE SCOPE OF WORK SCHEDULE TAKING PRECEDENCE. COLORS SHALL NOT BE SUBSTITUTED. 12. SURFACES NOT TO BE PAINTED SHALL BE PROTECTED DURING CLEANING & PAINTING OPERATIONS. 13. BEFORE ANY SURFACE IS COATED, IT SHALL BE CLEANED CAREFULLY OF ALL DUST, DIRT, GREASE, LOOSE RUST, MILL SCALE, OLD PAINT, ETC. 14. ALL CLEANED METAL SHALL BE PRIME COATED , AS SPECIFIED, IMMEDIATELY AFTER CLEANING TO PREVENT NEW RUSTING OR OXIDATION OF CLEANED SURFACES. 15. SURFACES 15.1 SURFACE PREPARATION (ALL METAL AND WOOD SURFACES) a. SOLVENT CLEANING SSPC-SP1 - THIS IS A METHOD FOR REMOVING OIL, GREASE, DRAWING AND CUTTING FLUIDS FROM THE SURFACE. A COMPLETE DESCRIPTION OF THE PROCEDURES CAN BE FOUND IN STEEL STRUCTURES PANTING COUNCIL SPECIFICATION "SSPC-SP-1 SOLVENT CLEANING" b. EMULSIFIER SOLVENT CLEANING - ALL AREAS TO BE PAINTED SHOULD BE CLEANED THOROUGHLY WITH A SOLUTION OF OIL AND GREASE EMULSIFIER. THIS CLEANER EMULSIFIES ALL OF THE OILY SUBSTANCE CONVERTING IT TO SOAP AND FLOATS IF OUT OF THE SURFACE. THOROUGHLY SCRUB ALL AREAS UNTIL SURFACE APPEARS CLEAN, AND THE RINSE WELL WITH CLEAN WATER. THIS PROCESS SHOULD BE REPEATED TO ENSURE THAT THERE ARE NO OTHER OILY CONTAMINANTS REMAINING. 15.2 WALLS AND COLUMNS - EGGSHELL FINISH a. PRIMER: APPLY ONE (1) COAT OF SUPER SPEC LATEX ENAMEL UNDERCOATER & PRIMER SEALER (PRODUCT # 253) AT A WET FILM THICKNESS OF 3.6 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.1 MILS PER COAT. (TINT PRIMER ONE SHADE LIGHTER THAN FINISH COAT). b. FINISH: APPLY TWO (2) COATS OF REGAL SELECT PREMIUM INTERIOR PAINT EGGSHELL FINISH (549) AT A WET FILM THICKNESS OF 3.8 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.5 MILS PER COAT. c. APPLICATION: BRUSH SMALL AREAS AND AROUND TRIM AND CEILING WITH PREMIUM QUALITY NYLON/POLYESTER BRUSH. FIRST COAT MAY BE SPRAYED, BUT BACKROLL WITH SOFT WOVEN COVER NO LARGER THAN ½” NAP TO MINIMIZE TEXTURE. SECOND COAT SHALL BE APPLIED BY ROLLER ONLY. 15.3 CEILINGS AND SOFFITS - FLAT FINISH a. PRIMER: APPLY ONE (1) COAT OF SUPER SPEC LATEX ENAMEL UNDERCOATER & PRIMER SEALER (PRODUCT # 253) AT A WET FILM THICKNESS OF 3.6 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.1 MILS PER COAT. (TINT PRIMER ONE SHADE LIGHTER THAN FINISH COAT). b. FINISH: APPLY TWO (2) COATS OF REGAL SELECT PREMIUM INTERIOR PAINT FLAT FINISH (547) AT A WET FILM THICKNESS OF 3.8 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.4 MILS PER COAT. c. APPLICATION: BRUSH SMALL AREAS AND AROUND TRIM AND CEILING WITH PREMIUM QUALITY NYLON/POLYESTER BRUSH. FIRST COAT MAY BE SPRAYED, BUT BACKROLL WITH SOFT WOVEN COVER NO LARGER THAN ½” NAP TO MINIMIZE TEXTURE. SECOND COAT SHALL BE APPLIED BY ROLLER ONLY. 15.4 WALL BASE, CASING, AND TRIM - SEMI GLOSS FINISH a. PRIMER: APPLY ONE (1) COAT OF SUPER SPEC LATEX ENAMEL UNDERCOATER & PRIMER SEALER (PRODUCT # 253) AT A WET FILM THICKNESS OF 3.6 MILS PER COAT TO ACHIEVE A. 1. D 6 F. 1. F E 5 IMMEDIATELY AFTER DEMOLITION AND/OR 1 WEEK PRIOR TO FLOOR INSTALLATION. IF THE G.C. FAILS TO PROVIDE REPORT, ANY FLOOR FAILURE ATTRIBUTED TO MOISTURE, IT WILL BE THE RESPONSIBILITY OF THE G.C. TO REPLACE (LABOR AND MATERIAL). c. ALL WORK INVOLVING WATER OR MOISTURE SHOULD BE COMPLETED BEFORE FLOOR INSTALLATION. d. ROOM TEMPERATURE AND HUMIDITY OF INSTALLATION AREA SHOULD BE CONSISTENT WITH NORMAL, YEAR-ROUND LIVING CONDITIONS FOR AT LEAST A WEEK BEFORE INSTALLATION. ROOM TEMPERATURE OF 60 TO 70 DEGREE F AND HUMIDITY RANGE OF 40 TO 60% IS RECOMMENDED. e. G.C. TO STORE FLOORING AT INSTALLATION SITE FOR 72 HOURS BEFORE INSTALLATION TO ALLOW FLOORING TO ADJUST TO ROOM TEMPERATURE AND HUMIDITY. DO NOT STORE DIRECTLY ON CONCRETE OR NEAR OUTSIDE WALLS. THIS FLOORING MAY NOT BE ACCEPTABLE FOR FULL BATHROOM INSTALLATIONS BECAUSE OF MOISTURE ASSOCIATED WITH SUCH LOCATIONS. f. COMMENCEMENT OF WORK IS ACCEPTANCE OF CONDITIONS. 3. MANUFACTURERS: REFER TO FINISH SCHEDULE. 4. ADHESIVE: AS RECOMMENDED BY MANUFACTURER TO ENSURE MAXIMUM DURABILITY OVER TIME; NONTOXIC, WATERPROOF TYPE SUITABLE FOR FLOORING, SUBSTRATE, AND ACCEPTABLE TO APPLICABLE AUTHORITIES. 5. MOISTURE VAPOR PROTECTION: BOSTIK MVP4 MOISTURE BARRIER OR AS RECOMMENDED BY MANUFACTURER; ONE-PART, TROWEL APPLIED, ELASTOMERIC, MOISTURE CURE URETHANE MEMBRANE. APPLY WITH 3/16" X 5/32" V-NOTCH TROWEL IS RECOMMENDED. 6. VINYL BASE: PROVIDE 1/8" COVED BASE FOR HARD FLOOR SURFACES AND STRAIGHT (TOP SET) BASE FOR CARPETED AREAS. PROVIDE PRE-MOULDED END STOPS AND EXTERNAL CORNERS. COLOR, TYPE AND HEIGHT AS SHOWN ON THE DRAWINGS. 4 5 6 7 8 9 10 A DRY FILM THICKNESS OF 1.1 MILS PER COAT. (TINT PRIMER ONE SHADE LIGHTER THAN FINISH COAT). b. FINISH: APPLY TWO (2) COATS OF REGAL SELECT PREMIUM INTERIOR PAINT SEMI-GLOSS FINISH (551) AT A WET FILM THICKNESS OF 3.8 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.4 MILS PER COAT. c. APPLICATION: BRUSH APPLY WITH PREMIUM QUALITY NYLON/POLYESTER BRUSH. PRIMER MAY BE SPRAYED. ALWAYS KEEP A WET EDGE DURING APPLICATION. A MAXIMUM OF ONE PINT PER GALLON OF CLEAN WATER MAY BE ADDED FOR A DESIRED CONSISTENCY AND FLOW. 15.5 METAL DOORS AND METAL DOOR JAMBS - SEMI GLOSS FINISH a. PRIMER: APPLY ONE (1) COAT OF SUPER SPEC HP ACRYLIC METAL PRIMER (P04) AT A WET FILM THICKNESS OF 4.0-4.5 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.7-2.3 MILS PER COAT. (TINT PRIMER ONE SHADE LIGHTER THAN FINISH COAT). b. FINISH: APPLY TWO (2) COATS OF REGAL SELECT PREMIUM INTERIOR PAINT SEMI-GLOSS FINISH (551) AT A WET FILM THICKNESS OF 3.8 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.4 MILS PER COAT. c. APPLICATION: FOR JAMBS: BRUSH APPLY WITH PREMIUM QUALITY NYLON/POLYESTER BRUSH. ALWAYS KEEP A WET EDGE DURING APPLICATION. FOR DOORS, A SOFT WOVEN COVER OF NO MORE THAN ½” IS RECOMMENDED FOR A SMOOTH APPEARANCE. A MAXIMUM OF ONE PINT PER GALLON OF CLEAN WATER MAY BE ADDED FOR A DESIRED CONSISTENCY AND FLOW. 15.6 CONCRETE FLOOR SEALERS: PROVIDE AS INDICATED ON THE DRAWINGS OR, IF NOT INDICATED THERE PROVIDE AS FOLLOWS FOR ALL EXPOSED CONCRETE AREAS WITHOUT A SPECIFIED FINISH a. INTERIOR CLEAR CONCRETE FLOOR SEALER (WATER-BASED) MP1#58, H&C SILICONE ACRYLIC CONCRETE SEALER, APPLIED PER MANUFACTURER'S WRITTEN INSTRUCTIONS. b. EXTERIOR CLEAR CONCRETE SEALER MP1#99, H&C CONCRETE & MASONRY WATER PROOFING SEALER, APPLIED PER MANUFACTURER'S RECOMMENDATIONS. 15.7 NOTES AND CAUTIONS a. ENSURE PROPER CONDITIONS FOR APPLICATION - BEFORE ANY SURFACE IS COATED, IT SHALL BE CLEANED OF ALL DUST, DIRT, GREASE, LOOSE RUST, MILL SCALE, LOOSE PAINT, ETC. IMPERFECTIONS AND HOLES IS SURFACES TO BE COATED SHALL BE CLEANED AND FILLED IN AN APPROVED MANNER. b. ALL PROJECTS SHOULD BE INSPECTED - AT VARIOUS STAGES OF SURFACE PREPARATION AND COATING APPLICATION. INSPECTIONS SHOULD BE CARRIED OUT BY G.C. INSPECTION & OWNERS REP. OR BY OUTSIDE INSPECTION FIRMS. c. CLEAN ANY BOLTS AND PAINT THEM USING A BRUSH - COLORS SHOULD BE DEGREASED BEFORE PRIMING. THE PRIMER AND TOPCOATS SHOULD BE APPLIED BY BRUSH TO ACHIEVE COMPLETE AND UNIFORM COVERAGE. d. MASK FAYING SURFACES AFTER PRIMING - IF FAYING SURFACES ARE TO BE PRIMED, THEY MUST BE MASKED AFTER PRIMING TO PREVENT TOPCOATING OF THE FAYING SURFACES. APPLICATION OF THE TOPCOAT TO A FAYING SURFACE MY LEAD TO LOOSENING OF FRICTION JOINTS. e. ENSURE ADEQUATE VENTILATION - ADEQUATE VENTILATION WHILE APPLYING AND CURING COATINGS IS IMPORTANT FOR HEALTH AND SAFETY REASONS AND TO ENSURE PROPER CURING OF THE COATING. WHEN APPLYING COATINGS IN CONFINED SPACES, SOLVENT VAPORS MAY ACCUMULATE, LEADING TO INTOXICATION OF WORKERS OR FIRE AND EXPLOSION. FLAMMABLE SOLVENTS AND THE ATOMIZED COATINGS ARE GENERALLY HEAVIER THAN AIR AND TEND TO SETTLE IN THE LOWER AREAS OF CONFINED CONSIDER THIS WHEN DESIGNING AND INSTALLING THE VENTILATION SYSTEM. f. PAINT BEFORE INSTALLING HARDWARE. G. 1. GENERAL: INSTALL VINYL WALL COVERING AND PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. 2. MAINTENANCE INSTRUCTIONS: FURNISH MANUFACTURER'S RECOMMENDED CLEANING MATERIALS AND APPLICATION METHODS, INCLUDING PRECAUTIONS IN USE OF CLEANING MATERIALS WHICH MAY BE DETRIMENTAL TO SURFACES. 3. MANUFACTURER: AS NOTED ON DRAWINGS. 4. TYPE: VINYL WALL COVERING CONFORMING TO FS DD-G-408, TYPE II VINYL WALL COVERING WITH CLOTH BACKING, MINIMUM 24 TO 26 OZ.; WITH MAXIMUM 25 FLAME SPREAD AND SMOKE DEVELOPED, ASTM E84 (UL CLASS A, UBC CLASS I). 5. ADHESIVE: NONTOXIC TYPE RECOMMENDED BY WALL COVERING MANUFACTURER TO SUIT APPLICATION. 6. PRIMER: PROVIDE NON-STAINING, NON-TOXIC RELEASE COAT PRIMER AS RECOMMENDED BY WALL COVERING MANUFACTURER. a. PROVIDE PRIMER WHICH ALLOWS REMOVAL OF WALL COVERING FROM GYPSUM BOARD WITHOUT DAMAGING PAPER FACING OF BOARD, AND WITHOUT PREMATURE SEPARATION OF WALL COVERING FROM WALL. 7. EXAMINATION: ENSURE SURFACES TO RECEIVE WALL COVERING ARE CLEAN, TRUE AND FREE OF IRREGULARITIES, DO NOT COMMENCE WITH WORK UNTIL SURFACES ARE SATISFACTORY. a. ENSURE WALL SURFACE FLATNESS TOLERANCE DOES NOT VARY MORE THAN 1/8" IN 10'-0", NOR VARY AT A RATE GREATER THAN 1/16" PER RUNNING FOOT. 8. PREPARATION: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS; FILL NICKS, GOUGES AND OTHER MINOR IMPERFECTIONS OF SUBSTRATES WITH LATEX FILLER; SAND SMOOTH, FLUSH WITH SURFACE; APPLY PRIME COAT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 9. APPLICATION: HANDLE AND APPLY WALL COVERING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS; MIX AND APPLY ADHESIVE IN ACCORDANCE WITH ADHESIVE MANUFACTURER'S RECOMMENDATIONS. a. USE FABRIC PANELS IN EXACT ORDER AS CUT FROM ROLLS; USE ROLLS IN CONSECUTIVE ORDER AS NUMBERED BY MANUFACTURER. b. HORIZONTAL SEAMS AND CUTTING AT CORNERS ARE NOT ACCEPTABLE; CUT NO CLOSER THAN 2" OF AN INSIDE CORNER, AND NOT CLOSER THAN 6" OF AN OUTSIDE CORNER. c. FILL SPACES ABOVE AND BELOW WINDOWS, DOORS, AND SIMILAR AREAS IN SEQUENCE FROM ROLL. 11 H. 1. 2. 3. 4. 5. 6. 7. I. 1. 2. J. 1. 2. K. 1. 2. 3. 12 13 14 GENERAL: PROVIDE TOILET ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS WITH DISABILITIES. MANUFACTURERS: AS NOTED ON DRAWINGS. TYPES: STAINLESS STEEL ACCESSORIES AS INDICATED ON DRAWINGS; PROVIDE GRAB BARS WITH CONCEALED MOUNTING, SIZES AND SHAPES AS INDICATED AND AS REQUIRED BY APPLICABLE CODES AND REGULATIONS. MATERIALS: STAINLESS STEEL, ASTM A666, COMMERCIAL GRADE, TYPE 302/304, NUMBER 4 SATIN FINISH, SATIN CHROME ACCEPTABLE WHERE STAINLESS STEEL IS NOT AVAILABLE FOR ACCESSORY ITEM SCHEDULED; GAGES AS STANDARD WITH MANUFACTURER OF SPECIFIED ITEMS. a. FASTENERS, SCREWS, AND BOLTS: HOT DIP GALVANIZED; AS RECOMMENDED BY ACCESSORY MANUFACTURER FOR COMPONENT AND SUBSTRATE. b. CONCEALED SURFACES: PRETREAT AND CLEAN, SPRAY APPLY ONE COAT PRIMER AND BAKED ENAMEL FINISH. FABRICATION: WELD AND GRIND SMOOTH JOINTS OF FABRICATED COMPONENTS; FORM EXPOSED SURFACES FROM ONE SHEET OF STOCK, FREE OF JOINTS. a. FABRICATE UNITS WITH TIGHT SEAMS AND JOINTS, EXPOSED EDGES ROLLED; HANG DOORS AND ACCESS PANELS WITH CONTINUOUS PIANO HINGES; PROVIDE CONCEALED ANCHORAGE WHERE POSSIBLE. b. PROVIDE STEEL ANCHOR PLATES AND ANCHOR COMPONENTS FOR INSTALLATION. c. FORM SURFACES FLAT WITHOUT DISTORTION; MAINTAIN FLAT SURFACES WITHOUT SCRATCHES AND WITHOUT DENTS; FINISH EXPOSED EDGES EASED, FREE OF SHARP EDGES WHERE POTENTIAL EXISTS FOR PHYSICAL CONTACT. d. HOT DIP GALVANIZE FERROUS METAL ANCHORS AND FASTENING DEVICES. e. SHOP ASSEMBLE COMPONENTS; PACKAGE COMPLETE WITH ANCHORS AND FITTINGS. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE CODES AND REGULATIONS. 9 10 CONSULTANT PROJECT # 150066 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect SEAL FIRE EXTINGUISHERS, CABINETS, AND ACCESSORIES AS REQUIRED BY APPLICABLE CODE. a. COMPLY WITH NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS. b. LISTED AND LABELED FOR TYPE, RATING, AND CLASSIFICATION BY AN INDEPENDENT TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. PRODUCTS a. FIRE EXTINGUISHERS: PORTABLE MULTIPURPOSE DRY-CHEMICAL TYPE, UL RATED 4-A: 60-B:, 10-LB NOMINAL CAPACITY, IN ENAMELED STEEL CONTAINER. b. FIRE EXTINGUISHER CABINETS: SIZED TO FIT FIRE EXTINGUISHER; APPROVED BY ARCHITECT. GENERAL: INSTALL STORAGE SHELVING AS INDICATED ON THE DRAWINGS; PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS. INSTALL UNITS AND ACCESSORIES AT LOCATIONS SHOWN IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS, LEVEL, PLUMB, SECURE AND AT PROPER HEIGHT PROVIDE SIGNAGE AS INDICATED ON THE DRAWINGS. COMPLY WITH APPLICABLE PROVISIONS IN ADA-ABA ACCESSIBILITY GUIDELINES AS APPLICABLE ALL COLORS, TYPE, STYLE, FONT SIZE AND MATERIALS TO BE AS SHOWN ON DRAWINGS AND AS SELECTED AND APPROVED BY OWNER. LOCATE SIGNS WHERE INDICATED, USING MOUNTING METHODS OF TYPES DESCRIBED AND COMPLYING WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, EXCEPT WHERE MORE STRINGENT REQUIREMENTS APPLY. A. GENERAL CONTRACTOR IS RESPONSIBLE FOR ASSEMBLY AND PLACEMENT OF OFFICE AND NON-SALES EQUIPMENT AND FURNITURE. B. THE CONTRACTOR IS RESPONSIBLE TO UNCRATE, ASSEMBLE, AND PLACE TRADE FIXTURES AND PRESENTATION ITEMS IN SALES AREA; FIXTURES TO BE LOCATED PER THE DIRECTION OF THE OWNER. A. ACCESS PANEL: FOR GYPSUM BOARD SOFFIT OR WALL (COLOR TO MATCH ADJACENT FINISH): 24" X 24" SURFACE MOUNTED, MODEL #AP24, AS MANUFACTURED BY INTEXFORMS INC. (916) 388-9933 OR OTHER WHICH MUST BE APPROVED BY OWNERS CONSTRUCTION MANAGER. SUBSTITUTE WITH "B" LABEL FIRE PANEL, MODEL FW 5050, KEY LOCK, ONLY IF A RATED DOOR IS REQUIRED PER CODES. B. ACCESS PANELS: FOR HVAC EQUIPMENT ARE NORMALLY INDICATED ON THE HVAC AND REFLECTED CEILING PLANS. IN ABSENCE OF DEFINED LOCATIONS, THE GENERAL CONTRACTOR IS TO FURNISH AND INSTALL ACCESS PANELS AS NECESSARY TO FURNISH REASONABLE, SAFE ACCESS TO SERVICE ALL SERVICEABLE COMPONENTS OF EACH PIECE OF EQUIPMENT. ASSUMED ACCESS SHALL BE BY A TECHNICIAN(S) STANDING FIRMLY ON A LADDER. WHERE ACCESS PANELS OR REMOVABLE DIFFUSERS CANNOT BE LOCATED IMMEDIATELY ADJACENT TO THE EQUIPMENT, C. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ASSEMBLE ALL MISCELLANEOUS NON-SALES AREA WALL STANDARDS, SHELVES, BRACKETS, ETC. D. LAVATORY FIXTURES & ACCESSORIES: REFER TO MECHANICAL DRAWINGS, TOILET ROOM DETAILS SHEET, AND RESPONSIBILITY SCHEDULE. E. RESTORE LANDLORD'S STRUCTURAL STEEL FIREPROOFING TO MAINTAIN INTEGRITY OF SAME AND FIREPROOF NEW STEEL AS REQUIRED. F. CLEANING: THE G.C. IS RESPONSIBLE FOR 2 PROFESSIONAL CLEANINGS. ONE CLEANING TO BE PRIOR TO THE PUNCH-LIST DATE. THE SECOND IS TO BE AFTER THE STORE IS MERCHANDISED BEFORE THE OPENING DATE. STORE IS TO BE TURNED OVER IN A DUST-FREE, DIRT-FREE CONDITION. CLEANING SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: 1. STOREFRONT GLASS (INSIDE AND OUT) 2. MIRRORS 3. STOREFRONT METAL 4. SIGNS 5. LIGHT FIXTURES INCLUDING CANS, TRIM, TRACK AND TRACK HEADS 6. FLOORING (PER MANUFACTURER'S RECOMMENDATIONS) 7. VINYL RESILIENT FLOOR TILE CLEANED AND WAXED 8. PRESENTATION ITEMS, PROPS, AND TRADE FIXTURES 9. WOOD BASE 10. WALL COVERINGS 11. NON-SALES SHELVING, STORAGE PLATFORMS, ETC. G. - GENERAL: G.C. TO COORDINATE AWNING AND FRAME INSTALLATION WITH OWNER'S PROJECT MANAGER. SUBCONTRACTOR TO PROVIDE BLOCKING AS REQUIRED. COORDINATE WITH OWNER'S VENDOR. 8 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 AT 2 RIVERCHASE GALLERIA 1 E. RIVERCHASE GALLERIA 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM SGH STORE #: 4933 DRAWN BY: PWD REVIEWED BY: RJH/JRM AUTHORIZED FOR: ARCHITECTURAL SPECIFICATIONS A-702 11 12 13 14 3 4 5 6 7 8 9 10 11 KEY NOTES J H 1. 2. K ADJACENT TENANT (N.I.C.) TOILET ROOM 102 A-16 A-1 3. 6 A-20 16 5 PANEL 'HP' XFMR 4. 10 A-19 TO LIGHT SEE E-102 J PANEL 'A' TIME CLOCK & CONTACTORS 13 A-19 4 5. A-24 11 9 18 A-5 7 S 20 21 13 6. 7. EX VAV 14 3 10. 100 16 A-10 STUB-UP (TYPICAL) H 12 (TYP) SALES 15 ON 8. 9. (E) 11. 22 12. 13. 14. 15. 16. 17. COL MALL COMMON AREA (N.I.C.) G ADJACENT TENANT (N.I.C.) 18. 19. 14 5 20. 2 (E) A-7 6 F 21. 4 NORTH A-14 22. FURNISH AND INSTALL FLOOR MOUNTED RECEPTACLE. SEE DIMENSION PLAN THIS SHEET FOR LOCATION. FURNISH AND INSTALL FLOOR MOUNTED POWER/DATA COMBINATION. CONTRACTOR SHALL FURNISH AND INSTALL (1) 1-1/4" CONDUIT WITH CAT6 CABLE PULLED BACK TO RACK FOR DATA OUTLET, SEE DIMENSION PLAN THIS SHEET FOR LOCATION. ON DEDICATED 24 HOUR CIRCUIT. CONDUIT FOR CASH REGISTER POWER CIRCUIT. COORDINATE INSTALLATION REQUIREMENTS WITH CONSTRUCTION MANAGER AND MILLWORK CONTRACTOR . CHECK LENGTH OF SCREWS BEFORE ATTACHING OUTLETS TO MILLWORK. VERIFY SCREWS ARE NOT TOO LONG AND WILL NOT DAMAGE OTHER SIDE OF MILLWORK WHEN TIGHTENED. TRENCH AND PATCH FLOOR AS REQUIRED, COORDINATE LOCATION IN FIELD WITH LANDLORD'S REPRESENTATIVE AND OWNER'S FIELD REPRESENTATIVE PRIOR TO ROUGH-IN . PROVIDE (1) 1" CONDUIT FOR POWER BELOW FLOOR. COORDINATE TRENCH LOCATIONS IN FIELD WITH LANDLORD'S REPRESENTATIVE. REPAIR FLOOR TO MATCH EXISTING CONDITIONS. PROVIDE (1) 1-1/4" CONDUIT FOR TELE/DATA BELOW FLOOR. COORDINATE TRENCH LOCATIONS IN FIELD WITH LANDLORD'S REPRESENTATIVE. REPAIR FLOOR TO MATCH EXISTING CONDITIONS. EXTEND CONDUIT FOR TELE/DATA TO TELE/DATA DISTRIBUTION EQUIPMENT. EXTEND CONDUIT TO TECH RACK DISTRIBUTION EQUIPMENT. EXISTING TELEPHONE BOARD WITH SURFACE MOUNTED QUAD RECEPTACLE TO REMAIN. REFER TO ELEVATION SHEET A-502 FOR MORE INFORMATION. EXISTING TIME CLOCK AND CONTACTORS REFER TO ONE LINE DIAGRAM FOR ADDITIONAL INFORMATION. SEE LIGHTING CONTROL DETAIL ON E-501. EXISTING ELECTRICAL DISTRIBUTION EQUIPMENT TO REMAIN. TRANSFORMER TO BE RELOCATED ABOVE CEILING. SEE ONE LINE DIAGRAM ON SHEET E-601. FURNISH AND INSTALL (1) DUPLEX RECEPTACLE MOUNTED AT 2'-6" A.F.F. (TO CENTER OF DEVICE) FOR FRAME WARMER. EXISTING RECEPTACLE MOUNTED ON CEILING FOR SHOW WINDOW AS REQUIRED BY N.E.C. FURNISH AND INSTALL RECEPTACLE FOR POWER OF DISPLAY CASES BELOW BASE OF MILLWORK SO CORDS AND RECEPTACLE ARE CONCEALED BEHIND FIXTURES. COORDINATE EXACT LOCATION WITH MILLWORK VENDOR. EXISTING MECHANICAL EQUIPMENT TO REMAIN. EXISTING INSTANTANEOUS WATER HEATER TO REMAIN. SEE EQUIPMENT CONNECTION SCHEDULE ON SHEET E-601. CONTROL CIRCUIT THROUGH LIGHTING SWITCH BANK. SEE DETAIL ON SHEET E-501. FURNISH AND INSTALL GFI DUPLEX RECEPTACLE ADJACENT TO UNIT IF NOT EXISTING/FURNISHED WITH EQUIPMENT. CIRCUIT AS INDICATED, FURNISH WEATHER PROOF ENCLOSURES AND COVERS AS REQUIRED. EXISTING THERMOSTAT/REMOTE SENSOR TO REMAIN. DUCT SMOKE DETECTOR/REMOTE TEST STATION: DUCT MOUNTED SMOKE DETECTOR IS FIELD INSTALLED. CONTRACTOR SHALL INTERLOCK SMOKE DETECTOR WITH HVAC UNIT, REMOTE TEST ALARM STATION AND FIRE ALARM SYSTEM (IF APPLICABLE). MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A COMPLETE SYSTEM. HVAC UNIT TO SHUT DOWN UPON ACTIVATION OF SMOKE DETECTOR. COORDINATE WITH LANDLORD TO AVOID CONFLICTS IN FIEL D. EXISTING FIRE ALARM CONTROL PANEL TO REMAIN. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO BID. EXISTING FIRE ALARM MANUAL PULL STATION TO REMAIN. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. EXISTING FIRE ALARM HORN/STROBE TO REMAIN. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. F1 SCALE: 12 POWER PLAN J 21. H 22. E 23. 24. 14 26. 27. REFER TO MECHANICAL PLAN FOR LOCATION OF MECHANICAL EQUIPMENT. FIELD VERIFY EXACT LOCATIONS. PROVIDE AND INSTALL ALL CONVENIENCE RECEPTACLES, SAFETY SWITCHES, WIRING, OR OTHER EQUIPMENT TO ENSURE A COMPLETE AND OPERABLE HVAC SYSTEM. ALL WALL MOUNTED RECEPTACLES, SWITCHES, AND COVERPLATES SHALL MATCH WALL, REFER TO SHEET A-201FOR FINISHES. THE CEILING RECEPTACLES AND COVERPLATES SHALL MATCH CEILING. CONDUIT FOR DATA/TELEPHONE OUTLETS SHALL HAVE NO MORE THAN THREE 90° BENDS. IF THE CONDUIT RUN REQUIRES MORE THAN THREE 90° BENDS, PROVIDE A PULL/JUNCTION BOX AFTER EACH SET OF THREE 90° BENDS. LABEL ALL COVERPLATES ON INSIDE FACE OF PLATE WITH CIRCUIT NUMBER AND PANEL DESIGNATION. I.E. "A-1". CIRCUIT SHALL BE WRITTEN WITH PERMANENT MARKER IN A CONTRASTING COLOR. ALL TELEPHONE/DATA CABLING TO BE RUN IN CONDUIT TO 6" ABOVE CEILING. PROVIDE 6' OF EXTRA CABLING AT ALL TELEPHONE/DATA TERMINATIONS. ALL CABLING SHALL BE PLENUM RATED. RUN PHONE/DATA CABLING (CAT 6) COMPLETELY IN CONDUIT IF LOCAL CODES/MUNICIPALITIES REQUIRE IT (FIELD VERIFY). ALL CABLING SHALL BE ROUTED AWAY FROM ALL ELECTRIC EQUIPMENT (WITHIN 18") AND SECURED TO STRUCTURE ABOVE. ALL TELEPHONE/DATA CABLING FURNISHED & INSTALLED BY ELECTRICAL CONTRACTOR. ALL MOUNTING HEIGHTS FROM THE CENTERLINE OF THE BOX TO THE FINISHED FLOOR ARE AS FOLLOWS, UNLESS NOTED OTHERWISE ON PLAN: SWITCHES-48", ELECTRICAL/TELEPHONE/DATA OUTLETS-18", THERMOSTATS-5'-0", TOP OF PANELBOARDS-6'-6". ALL ROOF PENETRATIONS TO BE COORDINATED WITH THE LANDLORD'S DESIGNATED ROOFING CONTRACTOR. FLEXIBLE CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO MILLWORK, INTERIOR LIGHTING FIXTURES, AND EQUIPMENT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE 6'-0". CONDUIT AND OUTLETS FOR SECURITY, DATA, TELEPHONE, AND ELECTRIC MAY REQUIRE REMOVAL OF CONCRETE SLAB OR ROUTING OF CONDUIT UNDER FLOOR IN SPACE BELOW. ALL WORK TO BE COORDINATED WITH THE LANDLORD DISCONNECT SWITCHES SHALL BE GENERAL DUTY IN APPROPRIATE NEMA ENCLOSURES. A LINE VOLTAGE, HORSEPOWER RATED DISCONNECT SWITCH SHALL BE INSTALLED ADJACENT TO EACH MOTOR. TRANSFORMER NEUTRALS SHALL BE SECURELY GROUNDED TO THE BUILDING STEEL AND COLD WATER PIPING PER THE N.E.C. AND LOCAL CODE REQUIREMENTS. INSTALL TRANSFORMERS ON VIBRATION ISOLATION PADS. ELECTRICAL EQUIPMENT EXPOSED TO WEATHER MUST BE WEATHERPROOF. ALL TEMPORARY WIRING SHALL BE REMOVED WHEN PERMANENT POWER IS AVAILABLE. IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS, THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING "AS BUILT" DRAWINGS FROM THE SUBCONTRACTORS AND SUBMITTING SAME TO SUN GLASS HUT. CONTRACTOR SHALL PURCHASE AT SGH NATIONAL ACCOUNT AGREED PRICING, ALL DISCONNECT SWITCHES, ELECTRIC DISTRIBUTION PANELS, TRANSFORMERS, CIRCUIT BREAKERS AND FUSES. CONTACT SUN GLASS HUT'S NATIONAL ACCOUNT REPRESENTATIVE FOR PRICING INFORMATION AND INCLUDE IN BID. SEE ARCHITECTURAL ELEVATIONS FOR ADDITIONAL INFORMATION ON PLACEMENT OF OUTLETS & SWITCHES. FOR ALL CASHWRAP MILLWORK ELECTRIC, DATA, AND TELEPHONE OUTLETS, REFER TO THE DETAILS ON SHEET E-501. ALL DATA/PHONE CABLING MUST BE PROPERLY IDENTIFIED WITH NUMBER AND/OR COLOR SYSTEM AT BOTH ENDS. ANY PENETRATIONS THROUGH FIRE-RESISTANT/RATED WALLS, PARTITIONS, FLOORS, AND CEILINGS SHALL BE FIRESTOPPED USING APPROVED UL METHODS TO MAINTAIN THE FIRE RESISTANCE RATING. RECEPTACLE CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS ABOVE 250'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. ELECTRICAL CONTRACTOR SHALL PROVIDE JUNCTION BOX AND RACEWAY FOR THERMOSTATS AT 60" A.F.F. THERMOSTATS AND TEMPERATURE SENSORS INSTALLED AND WIRED BY MECHANICAL CONTRACTOR. COORDINATE EXACT LOCATIONS WITH MECHANICAL CONTRACTOR. TYPICAL OF ALL. DUCTWORK AND PIPING SHALL NOT BE ROUTED OVER ELECTRIC PANELS OR TRANSFORMERS. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REVIEW ALL ARCHITECTURAL, MECHANICAL, PLUMBING, STRUCTURAL, FIRE ALARM AND FIRE PROTECTION AND ELECTRICAL DRAWINGS AND NOTES TO ENSURE THAT ALL ELECTRICAL REQUIREMENTS ARE MET. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES AND ORDINANCES. GC'S ELECTRICIAN TO PULL ALL LOW VOLTAGE TELEPHONE AND DATA LINES INCLUDING INSTALLATION OF DEVICES. PUNCH DOWN OF LINE(S) AT THE TERMINAL BOARD IS BY OTHERS. REFER TO SHEET E-501 FOR ABBREVIATIONS AND SYMBOLS REFER TO SHEET G-002 FOR RESPONSIBILITY SCHEDULE. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150066 Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com SEAL D 22'-3" 7'-9" C RIVERCHASE GALLERIA COL B 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM 14 SGH STORE #: 4933 DRAWN BY: SRH REVIEWED BY: RAP AUTHORIZED FOR: 1 " '-6 PLOTTED: 7/9/2015 - 12:50 PM P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\E-101_04933.dwg LAYOUT: E-101 25. USER: SHOLLAND 13 GENERAL NOTES AT 2 RIVERCHASE GALLERIA 1 POWER PLAN A NORTH A1 SCALE: E-101 DIMENSION PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 2 3 4 5 6 7 8 9 10 11 KEY NOTES 1. LIGHTING SPECIFICATIONS K MARK TYPE SUPPLIER A3W A3B J A3W A3B CONTECH LIGHTING CONTECH LIGHTING (E) (E) EXISTING PRODUCT TYPE WATT #LP LAMP CTL830P 13 N/A LED12P30SD30KNFL CTL830B 13 N/A 39 2 LED 12P30SD30KNFL LED TRACK HEAD - FRONT LOADING PAR30 GIMBAL RING TRACKHEAD WHITE FINISH RESTICKER FOR 13 WATTS LED TRACK HEAD - FRONT LOADING PAR30 GIMBAL RING TRACKHEAD WHITE FINISH RESTICKER FOR 13 WATTS 4. PAR20 EXISTING DUAL LAMP RECESSED LUMINARIES 5. (E) (E) EXISTING 42 1 42W TRIPLE TUBE 4 PIN EXISTING DUAL LAMP RECESSED LUMINARIES 6. TB4'-0" TB CONTECH LIGHTING LT-(2, 4, 6, 8)-B N/A N/A N/A PROVIDE TRACK, LENGTH AS INDICATED, BLACK FINISH. SOME PIECES WILL BE FIELD CUT TO MATCH LENGTH SHOWN ON PLANS. PROVIDE END FEEDS AND CONNECTORS AS REQUIRED. 7. 8. TW4'-0" TW CONTECH LIGHTING LT-(2, 4, 6, 8)-P N/A N/A N/A (R) (R) RELOCATED 42 1 42W TRIPLE TUBE 4 PIN RELOCATED DUAL LAMP RECESSED LUMINARIES (E) EXISTING 32 1 32W T8 EXISTING 4' SURFACE MOUNTED SINGLE TUBE STRIP (E) CIRCUIT VIA MASTER LIGHTING SWITCH BANK. SEE LIGHTING CONTROL DETAIL ON E-501. CIRCUIT SHOW WINDOW & SIGN LIGHTING THROUGH TIME CLOCK. FURNISH AND INSTALL JUNCTION BOX AND DISCONNECT TOGGLE TYPE SWITCH WITH MINIMUM 12" WHIP PER N.E.C. LOCATE ABOVE CEILING NEAR ACCESS PANEL IN CONCEALED LOCATION. CIRCUIT THROUGH TIMECLOCK/CONTACTOR. SEE ARCHITECTURAL SHEETS FOR SIGN LOCATION. FURNISH AND INSTALL GANGED SWITCH FOR LOCAL LIGHTING SWITCHES. PROVIDE COMMON FACEPLATE OR MULTIPLE FACEPLATES OF EQUAL WIDTHS. SEE LIGHTING CONTROL DETAIL ON E-501. CONNECT EMERGENCY FIXTURE TO EMERGENCY/NIGHT LIGHTING CIRCUIT (A-22) PER NEC 700-12(A) AND LIFE SAFETY CODE. EMERGENCY FIXTURE TO BE SERVED BY LOCAL LIGHTING CIRCUIT AHEAD OF ALL SWITCHING. PER NEC 700-12(A) AND LIFE SAFETY CODE. FURNISH AND INSTALL WALL MOUNTED OCCUPANCY SENSOR FURNISH AND INSTALL CONDUIT FROM TECH RACK TO 24" ABOVE CEILING FOR TERMINATION AT TRAFFIC COUNTER PROVIDE CAT6 DATA CABLE WITH MINIMUM 6FT COILED CABLE AT BOTH ENDS. FURNISH AND INSTALL CONDUIT FROM TECH RACK TO 24" ABOVE CEILING FOR TERMINATION AT WIRELESS POWER INJECTOR BRICK/WIRELESS ACCESS POINT PROVIDE CAT6 DATA CABLE WITH MINIMUM 6FT COILED CABLE AT BOTH ENDS. EXISTING SECURITY CAMERA FOR CCTV SYSTEM TO REMAIN. 18"x18" CORIAN ACCESS PANEL 2. 3. DESCRIPTION 9. 10. 11. 12 13 14 GENERAL NOTES H G NOTE: NOT ALL FIXTURES MAY BE USED ON THIS PROJECT F 1. EMERGENCY (EM) LUMINAIRES SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT" TO PROVIDE CONTINUOUS POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF. 2. ALL NIGHT-LIGHT (NL) LUMINAIRES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING 3. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE CONTRACTOR SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. 4. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON-SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT SGH PROJECT MANAGER FOR DIRECTION. 5. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT SGH PROJECT MANAGER FOR DIRECTION. 6. LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. 7. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE THRU-WIRING WHEREVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. LIGHTING FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE THRU-WIRING, ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. 8. CONTRACTOR'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY SGH. CONTRACTOR IS RESPONSIBLE TO ENSURE THE ADJUSTABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, CONTRACTOR SHALL CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH SGH. 9. EMERGENCY AND EXIT LUMINAIRES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST NATIONAL ELECTRICAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL-VOLTAGE WITH BATTERY BACKUP (120/277 VOLT INPUT). INSTALL A CENTRAL BATTERY SYSTEM WHERE THE USE OF INDIVIDUAL BATTERY UNITS ARE PROHIBITED BY LOCAL CODES. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT SGH PROJECT MANAGER FOR DIRECTION. 10. CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 11. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND QUANTITY OF LIGHTING FIXTURES. 12. CONTRACTOR IS RESPONSIBLE FOR ALL REFLECTED CEILING PLAN NOTES ON ARCHITECTURAL DRAWINGS. 13. LOW VOLTAGE WIRING: THE GC IS RESPONSIBLE TO DETERMINE IF LOW VOLTAGE WIRING IS REQUIRED BY EITHER LL OR BUILDING DEPARTMENT TO BE ENCASED IN CONDUIT, IF SO, CONDUIT TO BE PROVIDED AND INSTALLED BY GC'S ELECTRICIAN. 14. REFER TO SHEET E-501 FOR SYMBOLS LEGEND. 15. REFER TO RESPONSIBILITY SCHEDULE ON SHEET G-002. 16. CONTRACTOR SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150066 Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com SEAL F1 LIGHTING FIXTURE SCHEDULE J AT SCALE: H E 9 S C (E) W A3 W A3 (E) 1 S A X1 W A3 NL/EM 5 (R) A-6 A3B W A3 A3 B (E) A3 B W A3 (E) 5 (R) S C A-12 SPEAKER (TYPICAL) RIVERCHASE GALLERIA 5 (E) EM (E) (E) 3 COL (E) W A3 14 A-8 W 6 " '-0 W A3 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM 1 )T (N B A3B AP 8 A3 W (E) (R) NL/EM 5 " W A3 ADJACENT TENANT S C (E) " '-0 W A3 (E) A3 W (E) S (E) (E) 100 A3 W (E) A3W A3W A3W (E) (E) SALES 11 C (E) 1 (E) NL/EM 5 (E) A3W A3W (N) TW6'-0" A3W A3B A-2 (E) S (N) S C (N) TW5'-0" A3 B (E) A3W A3W A3W A3W A3W TB5'-0" A3W A3W A3W 6' -0 (E) A3W A3W A3W (N) TW8'-0" 3 1 A-4 TW S C (E) 10 P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\E-102_04933.dwg (E) TW 2 W A3 W A3 W A3 PLOTTED: 7/9/2015 - 1:23 PM 10 (TYP) S 7 D W A3 USER: SHOLLAND 2 A-15 4 SSS LAYOUT: E-102 TOILET ROOM RIVERCHASE GALLERIA 1 (E) 11 MALL COMMON AREA (N.I.C.) SGH STORE #: 4933 DRAWN BY: SRH (E) REVIEWED BY: RAP AUTHORIZED FOR: (E) LIGHTING PLAN & LIGHTING LEGEND NORTH A A1 SCALE: E-102 LIGHTING PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 2 3 4 5 6 7 8 9 10 11 12 ELECTRICAL SYMBOLS K IG 120 VOLT DUPLEX RECEPTACLE WP = WEATHERPROOF GFI = GROUND FAULT INTERRUPTER @ 16" 120 VOLT IG DUPLEX RECEPTACLE @ 16" LIGHTING/POWER PANELBOARD 120 VOLT DOUBLE DUPLEX (QUAD) RECEPTACLE @ 16" 120 VOLT SIMPLEX RECEPTACLE @ 16" 208V OR 120/208V RECEPTACLE @ 16" 120 VOLT DUPLEX RECEPTACLE CEILING MOUNTED SF = STOREFRONT CASH REGISTER SUPPLIES FIRE ALARM CONTROL PANEL FABP FIRE ALARM BOOSTER PANEL FAAP FIRE ALARM ANNUNCIATOR PANEL (REMOTE) A REMOTE ANNUNCIATOR/TEST STATION S CEILING MOUNTED PHOTO/IONIZATION DETECTOR H CEILING MOUNTED HEAT DETECTOR S PHOTO/IONIZATION DETECTOR-DUCT MOUNTED V ALARM HORN WITH VISUAL INDICATOR PANELBOARD 480/277V (TYP.) 3P BREAKER BROTHER PRINTER PANELBOARD 208/120V MAIN BREAKER THERMOSTAT S N HVAC SENSOR Z ZONE DAMPER TELEPHONE OUTLET BOX @ 16" DATA OUTLET BOX @ 16" DATA/TELEPHONE OUTLET BOX @ 16" VISUAL ALARM INDICATOR WITH NO HORN B ALARM BELL S FIRE ALARM SPEAKER WITH VISUAL INDICATOR S FIRE ALARM SPEAKER F MANUAL PULL STATION DATA OUTLET BOX - FLOOR MOUNTED DATA/TELEPHONE - FLOOR MOUNTED WALL MOUNTED VOLUME CONTROL @ 48" VS WALL MOUNTED VARIABLE SPEED CONTROLLER @ 48" K KEYPAD VC @ 80" NEUTRAL BAR P TC TRAFFIC COUNTER AP WIRELESS ACCESS POINT PRESSURE SWITCH TS TAMPER SWITCH R FIRE ALARM RELAY FIRE ALARM JUNCTION BOX MAGNETIC DOOR HOLDER-WALL OR FLOOR MOUNTED AS INDICATED D GLASS BREAK SENSOR @ 48" OCCUPANCY SENSOR @ 48" O S OCCUPANCY SENSOR - CEILING MOUNTED DOUBLE REMOTE HEAD DS DAYLIGHT SENSOR TRACK HEAD DD DIMMING SENSOR WALL MOUNTED FIXTURE V VACANCY SENSOR EM/NL WALL MOUNTED FIXTURE CURRENT LIMITER - NUMBER INDICATES AMPERAGE OF BREAKER RECESSED CAN LIGHT TIMER SWITCH @ 48" D DIMMER SWITCH @ 48" J N 3 J J J 2 ONE (1) 1" DIA. RIGID CONDUIT FOR POWER STUBBED BELOW CASHWRAP BASE (FRAME WARMER AND TECH RACK) ONE (1) 1" DIA. RIGID CONDUIT FOR POWER (IG) STUBBED BELOW CASHWRAP BASE (1 CIRCUIT) ONE (1) 1-1/4" DIA. RIGID CONDUIT FOR TELE/DATA STUBBED BELOW CASHWRAP BASE. PROVIDE 4 CAT6 CABLES. CUT HOLES AS REQUIRED AT REAR OF BASE FOR FLEX CONDUIT SECURITY CAMERA GENERAL DETAIL NOTES: CEILING MOUNTED SPEAKER SINGLE REMOTE HEAD 1. CHECK LENGTH OF SCREWS BEFORE ATTACHING OUTLETS TO MILLWORK. VERIFY SCREWS ARE NOT TOO LONG, SO AS NOT TO DAMAGE OTHER SIDE OF CASHWRAP WHEN SCREWS ARE TIGHTENED. 2. JUNCTION BOXES IN CASHWRAP ARE TO COME PREINSTALLED BY THE MILLWORK MANUFACTURER. F6 SCALE: EM/NL RECESSED CAN LIGHT TS CKT #2 CKT #1 DEVICE LOCATIONS DOOR CONTACT G WALL SWITCH - NUMBER INDICATES 2, 3 OR 4 POLE; LETTER INDICATES FIXTURE(S) TO BE CONTROLLED BY SWITCH S ACCESSIBLE EXOTHERMIC CONNECTION MOTION DETECTOR D C PUSHBUTTON S 2 SEAL QUAD RECEPTACLE (TYP. OF 1) BURGULAR SYSTEM PANEL CHIME/BELL TRANSFORMER S C TECH RACK EFFECTIVELY GROUNDED BUILDING STEEL COLUMN 1 F A B FRAME WARMER DUPLEX RECEPTACLE 24 HOUR CIRCUIT #2 QUAD RECEPTACLE 24 HOUR CIRCUIT #1 (TYP. OF 2) EQUIPMENT GROUND DRY TYPE TRANSFORMER D H M 3 BONDING JUMPER 1 NEUTRAL BAR @ 48" 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com EQUIPMENT LOCATIONS 2 GROUNDING ELECTRODE CONDUCTOR CONDUIT GROUND O S S F XX WATER FLOW SWITCH PS BURG CHIME/BELL G W F Shremshock Engineering, Inc. 1 GROUNDED (NEUTRAL CONDUCTOR) TELEPHONE OUTLET - FLOOR MOUNTED H SAFE SECURITY TRANSFORMER GROUND DETAIL NOTES @ 80" ALARM HORN V D TRASH CPU GROUND BAR T GROUND BAR JUNCTION BOX A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 TECH RACK CONSULTANT PROJECT # 150066 @ 60" 120 VOLT DUPLEX RECEPTACLE FLOOR MOUNTED J 14 SEE PLAN FOR CORRECT MONITOR RIGHT HAND/LEFT HAND LOCATION. FRAME WARMER PHONE TRANSFORMER (XFMR) FACP J 13 RECEIPT PRINTER MONITOR DRY-TYPE TRANSFORMER GROUND DETAIL F11 SCALE: 1 REGISTER CASHWRAP ELEVATION AT CEILING MOUNTED EXIT SIGN WALL MOUNTED EXIT SIGN SINGLE PHASE MOTOR E THREE PHASE MOTOR COMBINATION EMERGENCY AND EXIT LIGHT EQUIPMENT DISCONNECT SWITCH REMOTE EMERGENCY POWER PACK MAGNETIC COMBINATION MOTOR STARTER OR CONTACTOR DISCONNECT SWITCH WALL MOUNTED EMERGENCY LIGHT C E R MAGNETIC STARTER OR CONTACTOR MASTER LIGHTING SWITCH BANK CEILING MOUNTED EXISTING RELOCATED A-2 A-12 C2 GENERAL SALES (a) (SPST) GENERAL SALES (b) (SPST) DISPLAY & DECORATIVE LIGHTING (c) (SPST) USER: SHOLLAND PLOTTED: 7/9/2015 - 1:26 PM P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\E-501_04933.dwg LAYOUT: E-501 NON-MAGNETIC MANUAL MOTOR STARTER ABBREVIATIONS A D AFC AFF AFG AMP ANSI ARCH ASHRAE AWG ABOVE FINISHED CEILING ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERES AMERICAN NAT'L STANDARDS INST. ARCHITECT, ARCHITECTURAL AMERICAN SOCIETY OF HEATING, REFRIGERATION & AC ENGINEERS AMERICAN WIRE GAUGE B C BKR BLDG BMS CONDUIT CABLE TELEVISION SYSTEM CLOSED CIRCUIT TELEVISION CIRCUIT CEILING H HTR HVAC HZ HEATER HEATING, VENTILATING & A/C HERTZ KVA KW KWH KILOVOLT-AMPS KILOWATTS KILOWATT-HOUR LOCKED ROTOR AMPS LIGHTING M MAX MCA MCB MH MIN MOCP dB DECIBEL DIA (OR Ø) DIAMETER DISC DISCONNECT DN DOWN DWG DRAWING DPST DOUBLE POLE SINGLE THROW MTD MAXIMUM MINIMUM CIRCUIT AMPACITY MAIN CIRCUIT BREAKER MANHOLE, METAL HALIDE MINIMUM MAXIMUM OVER CURRENT PROTECTION MOUNTED N/A NEC NEMA NFPA NIC N.O. NTS F RELAY FOR MUSIC SHUT-OFF ON CENTER OCCUPATIONAL SAFETY &HEALTH ADMIN. NOT APPLICABLE NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MFR'S ASSOC. NATIONAL FIRE PROTECTION ASSOC. NOT IN CONTRACT NORMALLY OPEN NOT TO SCALE PF PH PVC D6 POWER FACTOR PHASE POLYVINYL CHLORIDE SCALE: NOT USED R RCP REV REX RLA RM 120V. REFLECTED CEILING PLAN, REVISION, REVISE REMOVE EXISTING RUNNING LOAD AMPS ROOM SF SPST V VA QUADRUPLEX RECEPTACLE THROUGH TYPICAL MONITOR UNDERWRITERS LABORATORIES, INC. UNLESS OTHERWISE NOTED UNINTERRUPTABLE POWER SUPPLY FIRE ALARM FIRE ALARM CONTROL PANEL FULL LOAD AMPS FOOT, FEET REFER TO ARCH DETAILS ON SHEET A-502 AND RESPONSIBILITY SCHEDULE ON SHEET G-002 FOR ADDITIONAL INFORMATION. EXTEND CABLE TO PROPOSED HEAD END EQUIPMENT LOCATION. PROVIDE ENOUGH EXCESS CABLE TO REACH ANY WALL IN BACK ROOM. COIL AND MARK CABLE AS CCTV. HEAD END EQUIPMENT LOCATION MUST BE WITHIN 10' OF THE 'NETWORK SWITCH ACCESS'. 2. FOR CAMERAS, PROVIDE WHITE PLENUM RATED CAT 5E CABLING. COIL 5' OF CABLING AT EACH CAMERA LOCATION FOR CONNECTIONS. 3. PROVIDE RJ-45 CONNECTORS AT CAMERA LOCATIONS ONLY. CONNECTORS NOT NEEDED AT THE HEAD END EQUIPMENT LOCATION. VOLT VOLT-AMPERE WATT A6 SCALE: ABBREVIATIONS AND SYMBOLS 1 2 3 4 5 C1 A-8 SPARE A-15 SPARE STOREFRONT SIGN SHOW WINDOW RECEPTACLES STOREFRONT TRACK LIGHTS POWER CONTACTOR FROM CIRCUIT A-41 THRU SWITCH 'c' SEE SHEET E-101 FOR ACTUAL NUMBER OF DEVICES, AND ADDITIONAL NOTES. ALL MATERIALS SHALL BE NEW AND BEAR UL LABELS. SUPPLY SHOP DRAWINGS FOR FIRE ALARM SYSTEM TO LOCAL AUTHORITY FOR APPROVAL PRIOR TO INSTALLATION. 4. FURNISH AND INSTALL ALL LABOR AND MATERIALS REQUIRED FOR A COMPLETE INSTALLATION AS INDICATED. 5. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NEC, NFPA, STATE AND LOCAL CODES. CAMERA (QUANTITY ON PLAN) 1. W W POWER CONTACTOR AND TC1 FROM CIRCUIT A-41 CONTACTOR CONTROLLED BY TIMECLOCK REUSE EXISTING ANNUNCIATING DEVICES, SEE SHEET E-101 FOR LOCATION AND QUANTITY. REUSE EXISTING PULL STATION SEE SHEET E-101 FOR LOCATION AND QUANTITY. 1. 2. 3. 3 SQUARE FEET, SQUARE FOOT SINGLE POLE SINGLE THROW U UL UON UPS F 1 T THRU TYP V EXISTING FIRE ALARM PANEL. SEE SHEET E-101 FOR LOCATION AND ADDITIONAL NOTES 2 DVD-R S A1 SCALE: R P V N E FA FACP FLA FT OC OSHA LRA LTG ETR EXISTING TO REMAIN EWC ELECTRICAL WATER COOLER EXH EXHAUST EX, EXIST EXISTING A G GAS, GROUND GC GENERAL CONTRACTOR GFI, GFCI GROUND FAULT INTERRUPTER GRND GROUND L D B O K BREAKER BUILDING BUILDING MANAGEMENT SYSTEM C C CATV CCTV CKT CLG G RIVERCHASE GALLERIA 1 1. C2 UPON ALARM SIGNAL FROM ANY INITIATING DEVICE THE FIRE ALARM PANEL SHALL: A. INITIATE AN ALARM SIGNAL AT TENANT'S FIRE ALARM PANEL. B. SHUT DOWN TENANT'S HVAC SYSTEM (IF APPLICABLE) C. INITIATE TENANT'S HORN/STROBES. D. ACTIVATE THE TENANT ZONE SMOKE CONTROL EXHAUST SYSTEM.(IF APPLICABLE) E. NOTIFY LOCAL FIRE DEPARTMENT OF FIRE EMERGENCY LOCATION. F. SEND SIGNAL TO OWNERS SECURITY AND LOSS PREVENTION CENTRAL MONITORING SYSTEM. 6 SGH STORE #: 4933 DRAWN BY: SRH REVIEWED BY: RAP AUTHORIZED FOR: ELECTRICAL DETAILS & ABBREVIATIONS SCALE: 7 RIVERCHASE GALLERIA 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM NOTES: · ALL CONTACTORS ARE NORMALLY OPEN, ELECTRICALLY HELD CLOSED, WITH THE NUMBER OF POLES AS SHOWN. · SUPPLY POWER TO CONTACTORS THRU A-41 IN ALL CASES. · LOCATE CONTACTORS AND TIME CLOCK ADJACENT TO PANEL 'A'. A8 CCTV SYSTEM SALES TRACK LIGHTS SALES TRACK LIGHTS SALES AREA DISPLAY CASES SALES AREA DISPLAY CASES A-4 A-6 A-10 A-20 SPARE SPARE SPARE SPARE A12 SCALE: FIRE ALARM SYSTEM 8 9 10 11 E- 501 LIGHTING CONTROL DIAGRAM 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 K DOUBLE NUT AND SQUARE WASHERS. CONSULTANT PROJECT # 150066 TRANSFORMER FASTEN UNISTRUT TO JOIST CHORD ANGLE WITH P2785 UNISTRUT CLAMP (TYP. OF 8). Shremshock Engineering, Inc. MECHANICAL EQUIPMENT FEEDER/CONNECTION SCHEDULE J H FEEDERS ITEM VOLTAGE HP KW M.C.A. WIRE COND TYPE OF CONN EX IWH 120V 1PH --- 3.6 --- EXISTING 1" EXSTING EX VAV 480V 3PH --- --- 6 EXISTING 3/4" THRU DISC. SWITCH DISC SW BRANCH BREAKER 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com REMARKS P2000 UNISTRUT FRAME TO SPAN (2) JOISTS. 30A-1P EXISTING SEE NOTE #1 15A-3P SEAL NOTE: 1. DISCONNECT IS FURNISHED WITH UNIT. 2. DISCONNECT IS TO BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR 1/2" HANGER RODS (TYP. OF 4). VIBRATION ISOLATION PADS (TYP. OF 4) DOUBLE NUT HANGER ROD TO SUPPORT UNISTRUT FRAME AFTER EQUIPMENT IS LEVELED. P2000 UNISTRUT FRAME G G5 SCALE: EQUIPMENT SCHEDULES TRANSFORMER JOIST MOUNT F LEASE LINE E AT TENANT EXISTING 1 1/2" CONDUIT BACK TO LANDLORDS ELECTRICAL ROOM. FIELD VERIFY PRIOR TO BID USER: SHOLLAND PLOTTED: 7/9/2015 - 12:55 PM P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\E-601_04933.dwg LAYOUT: E-601 CEILING RELOCATED XFMR 15KVA, 480V, 3PH PRIMARY, 208V/120Y SECONDARY. EXISTING TRANSFORMER TO BE RELOCATED ABOVE CEILING EXISTING ELECTRICAL SWITCHGEAR D C-1 C-2 ZONE ZONE "SF" "C" TC EXISTING PANEL A 120/208V 3PH, 4W 60A MCB #6 CU BOND TO BUILDING STEEL RIVERCHASE GALLERIA G1 SCALE: EXISTING PANEL HP 277/480V 3PH, 4W 60A MCB C FINISH FLOOR APPROX. 150'-0" RIVERCHASE GALLERIA 1. 2. 3. B 4. 5. 6. 7. 8. 9. A 10. HVAC CIRCUIT BREAKERS TO BE "HACR" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. TENANTS ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT K.A.I.C. RATING OF LANDLORD'S DISTRIBUTION EQUIPMENT. FURNISH AND INSTALL TENANTS ELECTRICAL SYSTEM TO MATCH. ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT, UNDER LOAD CONDITIONS, TO ±7% BETWEEN PHASES: A/B, B/C, A/C REGARDLESS OF CIRCUITING INDICATED. ELECTRICAL CONTRACTOR SHALL MAINTAIN PROPER CLEARANCE FOR ELECTRICAL EQUIPMENT PER N.E.C. ARTICLE 110.26. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM/ AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. TENANT'S NAME AND SPACE SHALL BE ENGRAVED ON A BAKELITE PLATE WITH 1" HIGH LETTERS. SCREW FASTEN TO THE METER SOCKET AND DISCONNECT SWITCH AT THE SERVICE DISTRIBUTION POINT. ALL CONNECTIONS TO LANDLORD'S SERVICE EQUIPMENT SHALL BE AS DIRECTED BY LANDLORD'S SITE REPRESENTATIVE. TENANT ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TERMINATION EXPENSES. SYSTEM SHALL BE GROUNDED TO THE MAIN BUILDING'S GROUNDING SYSTEM. ELECTRICAL CONTRACTOR SHALL INCLUDE IN BID ALL WORK AND MODIFICATIONS REQUIRED TO COMPLY WITH LANDLORDS TENANT CRITERIA, ENERGY CODES, NATIONAL, STATE AND LOCAL CODES. ALL EQUIPMENT TO BE SUPPLIED & INSTALLED PER RESPONSIBILITY SCHEDULE AS SHOWN ON THIS SHEET. 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM SGH STORE #: 4933 DRAWN BY: SRH REVIEWED BY: RAP AUTHORIZED FOR: ELECTRICAL SINGLE LINE DIAGRAM AND PANEL SCHEDULES A1 SCALE: A9 SCALE: ELECTRICAL SINGLE LINE DIAGRAM 1 2 3 4 5 6 7 8 E-601 PANEL SCHEDULES AND LOAD SUMMARY 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 26 05 29 DISTRIBUTION M. ALL PERMITS REQUIRED BY LAWS, ORDINANCES AND BUILDING CODES HAVING JURISDICTION SHALL AH. MANUFACTURER'S CATALOG CUTS MAY BE SUBMITTED FOR STANDARD CATALOG LIGHTING BE OBTAINED AT PROPER TIME BY AND AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. FIXTURES AND OTHER EQUIPMENT. CATALOG CUTS MAY BE MARKED UP TO MEET THE PROJECTA. GENERAL CONTRACTOR SHALL FURNISH ALL LABOR, MISC. MATERIALS AND EQUIPMENT SPECIFICATIONS. CUTS SHALL BE MARKED TO INDICATE MODEL NUMBER, SIZE, TYPE, COLOR, THE FOLLOWING TERMS SHALL APPLY TO ALL WORK DONE UNDER THIS CONTRACT: NECESSARY TO INSTALL ALL OF THE ELECTRICAL SERVICE FROM THE LANDLORD'S ELECTRICAL N. ALL ELECTRICAL WORK SHALL BE INSPECTED BY THE GOVERNMENTAL AGENCY HAVING RATING, ETC., OF THE ITEM TO BE FURNISHED. SERVICE ROOM INCLUDING (AS INDICATED ON SHEET E4.0) BUT NOT LIMITED TO THE SECONDARY 1. ANY REFERENCE TO TENANT OR TENANT'S CONSTRUCTION MANAGER OR FURNISHED BY ANY JURISDICTION, INCLUDING LOCAL INSPECTION AUTHORITIES. CABLES, CONDUIT, PULL WIRE AND GROUND ROD AND SLEEVE AS REQUIRED. COORDINATE AI. PROVIDE INSTRUCTION TO TENANT'S OPERATING PERSONNEL AS NECESSARY, SHOWING LOCATIONSREQUIREMENTS WITH LANDLORD PRIOR TO BID. THE GENERAL CONTRACTOR SHALL COORDINATE OF THE ABOVE REFERS TO SUNGLASS HUT. O. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE AND PROPER OPERATION OF MAJOR ITEMS OF EQUIPMENT AND SYSTEM COMPONENTS AND 2. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND INSTALLATION OF THE DISCONNECT SWITCHES AND PANELBOARD WITH THIS WORK. REFERRING TO THE OPERATING INSTRUCTION MANUAL DESCRIBED BELOW AS A GUIDE. SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATIONS SECTIONS, APPLY TO THIS SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL AND THE OTHER SECTIONS OF DIVISION 26 THROUGH 28. B. ALL CONDUCTORS SHALL BE COPPER. ALUMINUM CONDUCTORS AREPERMITTED. 3. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW BE SUBJECT TO APPROVAL IN WRITING, THROUGH SHOP DRAWING SUBMITTAL PROCESS, BY AJ. GENERAL CONTRACTOR SHALL GUARANTEE THIS WORKMANSHIP AND MATERIALS, EXCEPT FOR TENANT-SUPPLIED MATERIALS, FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE C. (IN COORDINATE WORK PROVIDED BY LANDLORD PRIOR TO BID AND INCLUDE THE COST OF ANY DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF TENANT'S CONSTRUCTION MANAGER PRIOR TO ACCEPTANCE. THE USE OF ANY UNAUTHORIZED THIS WORK AND THE WORK OF THE SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE.WRITING) OF THE INSTALLATION BY TENANT'S CONSTRUCTION MANAGER/ENGINEERING MANAGER SUCH WORK AS DIRECTED BY LANDLORD. WIRING OF METERING EQUIPMENT SHALL BE BY GENER AND LEAVE THIS WORK IN PERFECT ORDER AT COMPLETION. THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE SUBCONTRACTORS WITH A COMPLETE CONTRACTOR AS DIRECTED BY THE ELECTRIC COMPANY. P. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO TENANT'S SET OF BID DOCUMENTS. 4. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OFCONSTRUCTION MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN AK. SHOULD DEFECTS DEVELOP WITHIN GUARANTEE PERIOD, GENERAL CONTRACTOR SHALL, UPOND. METERING EQUIPMENT SHALL BE FURNISHED BY GENERAL CONTRACTOR AND INSTALLED TO THE PROJECT TO ALLOW SEVEN (7) WORKING DAYS FOR TENANT'S CONSTRUCTION MANAGER'S REVIEWNOTICE OF SAME, REMEDY SUCH DEFECTS AND HAVE DAMAGES TO OTHER WORK OR FURNISHINGS MALL'S REQUIREMENTS. THIS WORK AND THE WORK OF THE SUBCONTRACTORS TO COMPLY WITH THE OWNER'S WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THECAUSED BY DEFECTS OR WORK OR CORRECTIONS TO SAME REPAIRED AND/OR REPLACED AT THIS SCHEDULE AND THE PROJECT COMPLETION DATE. STAMP OF THE GENERAL CONTRACTOR AND/OR SUB-CONTRACTOR SHOWING THAT THEY HAVE CONTRACTOR'S EXPENSE TO CONDITION BEFORE SUCH DEFECTS OR DAMAGE. 5. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE E. DISCONNECT SWITCHES SHALL BE HEAVY-DUTY TYPE, UL LISTED. REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. AL. COMPILE TWO (2) WRITTEN MANUALS OF OPERATING INSTRUCTIONS INCLUDING COPIES OF SHOP DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND F. DISCONNECT SWITCHES SHALL BE BY SQUARE D, GENERAL ELECTRIC, SIEMENS, OR CUTLER DRAWINGS AND A LISTING OF EQUIPMENT SUPPLIERS.MATERIAL SHALL BE AS FOLLOWS: QUALIFIED IN THE CONTRACTOR'S BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF HAMMER. Q. FOR ANY PHASED STORE CONSTRUCTION, THIS CONTRACTOR IS TO INCLUDE IN THIS BID ALL KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NECESSARY ELECTRICAL SERVICE CHANGES REQUIRED TO KEEP THE OPERATING PHASE OF THE 1. LIST OF MAJOR EQUIPMENT USED IN PROJECT ACCOMPANIED BY CONTRACTOR PURCHASEG. ALL SWITCHES SHALL HAVE SWITCH BLADES WHICH ARE FULLY VISIBLE IN THE "OFF" POSITION ORDER NUMBERS AND SUPPLIERS' NAMES AND ADDRESSES. STORE'S ELECTRIC SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE WITH TENANT'S NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. WHEN THE SWITCH DOOR IS OPEN. SWITCHES SHALL HAVE REMOVABLE ARC SUPPRESSORS 6. REFER TO RESPONSIBILITY SCHEDULE ON THE ARCHITECTURAL DRAWINGS FOR INFORMATIONCONSTRUCTION MANAGER AND LANDLORD (IN WRITING) ONE WEEK PRIOR TO ANY SHUT DOWN OF 2. ONE COPY OF EACH SHOP DRAWING GROUPED BY TYPES OF EQUIPMENT, I.E., LIGHTING WHERE NECESSARY TO PERMIT EASY ACCESS TO LINE SIDE LUGS. LUGS SHALL BE FRONT THE P.O.S., CASH REGISTERS, ELECTRICAL, TELEPHONE OR FIRE ALARM SYSTEMS. ADVISE GENERAL FIXTURES, PANELBOARDS, ETC. IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. REMOVABLE AND UL LISTED FOR 75 DEGREES C., ALUMINUM OR COPPER WIRES. CONTRACTOR AND TENANT AT TIME OF BID IF ANY CONFLICTS EXIST. 3. SECTION FOR EACH SYSTEM, INCLUDING: a. BRIEF DESCRIPTION OF SYSTEM OPERATION WITH LOCATION OF MAJOR COMPONENTS. H. SWITCHES SHALL BE QUICK-MAKE, QUICK-BREAK. THE OPERATING HANDLE SHALL BE AN INTEGRA PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL NEW b. LIST OF ITEMS IN SYSTEM REQUIRING PERIODIC SERVICE. REQUIRES SEPARATE SECTION COMPLETE ELECTRICAL SYSTEM AS INDICATED ON DRAWINGS, AS REQUIRED BY CODE AND AS R. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF PART OF THE BOX, NOT THE COVER. PROVISIONS FOR PADLOCKING THE SWITCH IN THE "OFF" EXISTING WORK. COORDINATE ANY EXISTING EQUIPMENT TO BE LEFT INTACT AND ADVISE TENANT'S FOR EACH OF: ELECTRICAL DISTRIBUTION SYSTEM FROM THE SERVICE ENTRANCE TO EACH POSITION WITH AT LEAST THREE LOCKS SHALL BE PROVIDED. SWITCHES SHALL HAVE A DUAL SPECIFIED HEREIN, IN DIVISIONS 26, 27, AND 28. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO, CONSTRUCTION MANAGER AT TIME OF BID. LIGHTING AND POWER PANEL AND OTHER SYSTEMS (I.E. CONTROL SYSTEMS AND ANY OTHER COVER INTERLOCK TO PREVENT UNAUTHORIZED OPENING OF THE SWITCH DOOR WHEN THE THE FOLLOWING: GENERAL CONTRACTOR SYSTEM LISTED IN THESE SPECIFICATIONS.) HANDLE IS IN THE "ON" POSITION, AND TO PREVENT CLOSING OF THE SWITCH MECHANISM WITH S. ELECTRICAL CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF 1. TEMPORARY SERVICE AS REQUIRED. THE DOOR OPEN. THE HANDLE POSITION SHALL INDICATE WHETHER THE SWITCH IS "ON" OR "OFF ALL EXISTING CONDUIT, FIRE ALARM SYSTEM, SWITCH GEAR, PITCH POCKETS AND EQUIPMENT,AM. ETC. OWNER'S SHALL PROVIDE A COMPLETE 12-MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT 2. PRIMARY DISTRIBUTION BY ELECTRIC COMPANY. UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PROVIDED BY TENANT AND TENANT'S VENDORS. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL 3. EMERGENCY AND EXIT LIGHTING SYSTEMS. I. SWITCHES SHALL BE FURNISHED IN NEMA 1 GENERAL PURPOSE ENCLOSURE EXCEPT ALL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONIES 4. CONDUIT AND CABLES FOR TELEPHONE AND DATA SYSTEMS AS SHOWN ON THE DRAWINGS. PRESUMED ABANDONED EQUIPMENT, CONDUIT AND SWITCH GEAR PRIOR TO REMOVAL. PITCH SWITCHES LOCATED OUTDOORS SHALL BE NEMA 3R WEATHERPROOF (WP). NEMA 3R ENCLOSURE POCKETS SHALL BE REMOVED AND THE ROOF PATCHED, AS REQUIRED BY THE LANDLORD. ALL SHOULD BE INCLUDED IN THE BID. 5. ELECTRICAL PANEL AND BRANCH CIRCUIT WIRING. SHALL BE MANUFACTURED FROM GALVANIZED STEEL. ENCLOSURES SHALL HAVE A GRAY BAKED EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE 6. WIRING DEVICES AND PLATES. ENAMEL FINISH, ELECTRODEPOSITED, ON CLEANED, PHOSPHATIZED STEEL. REMOVED AND ROOF/WALL/FLOOR PATCHED/REPAIRED TO LIKE NEW CONDITION. EXISTING AN. AT THE END OF THE PROJECT, THIS CONTRACTOR SHALL CLEAN ALL EQUIPMENT, INCLUDING LIGHT 7. LIGHTING FIXTURES AND LAMPS, INSTALLATION AND WIRING. ABANDONED CONDUIT OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE FIXTURES, TO THE SATISFACTION OF OWNER'S. ALL DUST, DIRT, DEBRIS, PAINT AND FOREIGN J. 8. LIGHTING CONTROLS. SWITCHES SHALL BE RATED FOR AC. FUSIBLE SWITCHES MUST ACCEPT CLASS R FUSES AND HAV INACCESSIBLE, ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN MATTER SHALL BE REMOVED FROM ALL EQUIPMENT. 9. ELECTRICAL CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS, SIGNS, CORNICE PROVISIONS TO REJECT ALL FUSES EXCEPT CLASS R. THE UL LISTED SHORT CIRCUIT RATING OF THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, LIGHTING, CASE LIGHTING, ETC., AS SHOWN ON DRAWINGS. THE SWITCHES SHALL BE 200,000 RMS SYMMETRICAL AMPERES WHEN CLASS R FUSES ARE ABANDONED CONDUIT MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM EXTENT OF DEMOLITION 10. INSTALLATION OF CONDUIT AND CABLES FOR SOUND SYSTEM AS SHOWN ON DRAWINGS. USED. 26 05 19 LOW VOLTAGE ELECTRICAL POWER CONDUCTORS PRIOR TO BID AND INCLUDE IN PROPOSAL. 11. SMOKE/FIRE ALARM WIRING, DEVICES AND CONDUIT, AS SHOWN OR DESCRIBED ON A. CONDUCTORS SHALL BE COPPER, 90°C TYPE THHN OR THWN UNLESS NOTED OTHERWISE ON THE DRAWINGS OR AS NECESSARY TO MEET LANDLORD, STATE, LOCAL, INSURANCE AND FIRE K. NAMEPLATES SHALL INDICATE FUNCTION OF EACH DEVICE. NAMEPLATES SHALL BE LAMINATED T. GENERAL CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE DRAWINGS, THE MINIMUM COPPER WIRE SIZES FOR WET AND DRY AREAS AS DEFINED BY THE DEPARTMENT REQUIREMENTS. PHENOLIC WITH A WHITE SURFACE AND BLACK CORE. USE 1/16" THICK MATERIAL FOR 12. INSTALLATION OF CONDUITS STUBBED TO ABOVE CEILING FOR HVAC. ALSO, ANY ADDITIONAL INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITIONN.E.C. SHALL BE AS FOLLOWS: NAMEPLATES UP TO 2"X4" AND USE 1/8" THICK MATERIAL FOR LARGER SIZES. ALL NAMEPLATES AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, CONDUIT FOR HVAC CONTROL EQUIPMENT WHERE PLENUM RATED CABLES ARE NOT SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. GENERAL CONTRACTOR TO WHICH SHALL EXTEND 2" ABOVE THE FLOOR. 20 AMP CKT BKR OR FUSE = #12 AWG, THHN/THWN PERMITTED. COORDINATE WITH THE LOCAL BUILDING AUTHORITY OR BUILDING INSPECTOR ON WHICH ITEMS 30 AMP CKT BKR OR FUSE = #10 AWG, THHN/THWN 13. THE GENERAL CONTRACTOR SHALL PAY FOR ALL ELECTRICITY PRIOR TO STORE SHOULD HAVE A NAMEPLATE. U. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR FLOORS SHALL BE FIRE SEALED 40 AMP CKT BKR OR FUSE = #8 AWG, THHN/THWN MERCHANDISING, AND INCLUDE COST IN BID. WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO 50 AMP CKT BKR OR FUSE = #8 AWG, THHN/THWN L. ALL FUSES SHALL BE UL LISTED, CURRENT-LIMITING TYPE, MINIMUM 200,000 AMPS RETAIN THEIR FIRE RATING. 100 AMP CKT BKR OR FUSE = #3 AWG, THHN/THWN WORK WHICH SHALL BE PERFORMED BY OTHERS, UNLESS NOTED OTHERWISE, INCLUDES THE INTERRUPTING CAPACITY. 125 AMP CKT BKR OR FUSE = #1 AWG, THHN/THWN FOLLOWING: V. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS AND PARTITIONS SHALL BE STANDARD WEIGHT 200 AMP CKT BKR OR FUSE = #3/0 AWG, THHN/THWN M. FUSES 1 AMP AND ABOVE SHALL BE BUSSMANN "LOW PEAK" RK-1. 250 VOLT FUSES SHALL BE STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH 1. TEMPERATURE CONTROL WIRING THAT IS FURNISHED BY OTHERS PRE-WIRED IN UNITS. USED ON 208/120 VOLT SYSTEMS. 600 VOLT FUSES SHALL BE USED ON 480/277 VOLT SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL CONDUIT, SLEEVES SHALL BE 22 U.S.G. B. MINIMUM WIRE SIZES FOR 20A BRANCH CIRCUITS SHALL BE ADJUSTED FOR DISTANCE, 2. TELEPHONES AND FINAL CONNECTION OF WIRING THERETO. SYSTEMS. GALVANIZED STEEL MINIMUM. MEASURED FROM THE PANELBOARD CIRCUIT BREAKER TO THE FURTHEST OUTLET, 3. INTERNAL WIRING OF EQUIPMENT FURNISHED AND PRE-WIRED BY OTHERS. AS FOLLOWS: 4. SECURITY SYSTEM FURNISHED AND INSTALLED BY SECURITY CONTRACTOR (IF REQUIRED). N. CONTROL FUSES FOR MOTOR STARTERS, CONTACTORS, AND CONTROL PANEL TRANSFORMERS W. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, WIRE, UNISTRUT, LESS THAN 100 FT - #12 SHALL BE BUSSMANN FNQ-R SIZED AT 500% RATED CURRENT. C-CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE BETWEEN 101 AND 150 FEET - #10 ELECTRICAL EQUIPMENT FURNISHED BY OTHER TRADES OR BY TENANT AND SPECIFIED IN OR SHOWN BETWEEN 151 AND 250 FEET - #8 ON CONTRACT DOCUMENTS SHALL BE INSTALLED AND CONNECTED BY GENERAL CONTRACTOR, INSTALLATION OF WORK. O. FURNISH SPARE FUSES TO THE TENANT IN THE FOLLOWING QUANTITIES: 10% OF TOTAL PROJECT OVER 251 FEET - #6 EXCEPT AS OTHERWISE NOTED. PROVIDE BRANCH CIRCUIT CONNECTIONS TO ELECTRICALLY QUANTITY (BUT NOT LESS THAN THREE (3) FOR EACH TYPE AND RATING OF FUSES). OPERATED EQUIPMENT FURNISHED BY OTHERS AS SPECIFIED IN OR SHOWN ON THE CONTRACTX. HANGERS, SUPPORTS OR FASTENINGS SHALL BE PROVIDED AT EACH ELBOW, AT THE ENDS OF STRAIGHT RUNS TERMINATING AT BOXES OR CABINETS, AND AT INTERMEDIATE POINTS AS C. CONDUCTORS USED FOR EMERGENCY LIGHTING CIRCUITS SHALL BE #10 AWG, MINIMUM, DOCUMENTS. TEMPORARY WIRING FOR OTHER CONTRACTORS SHALL BE INSTALLED BY THE P. TYPED LIST OF ALL SPARES SHALL ALSO BE INCLUDED. ELECTRICAL CONTRACTOR WHO SHALL BE ENTIRELY RESPONSIBLE TO THE TENANT FOR THE SAFE REQUIRED BY CODE. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, AND SHALL BE RUN IN SEPARATE CONDUIT USED FOR NO OTHER PURPOSE. BUT NOT TO OTHER CONDUIT OR PIPING. HANGERS UPPER ATTACHMENT MUST BE SUPPORTED AND SATISFACTORY OPERATION OF SAID TEMPORARY WIRING. CONTRACTOR REQUIRING SUCH Q. EXISTING PANELBOARDS TO REMAIN. FROM THE TOP OF THE BAR JOIST. HANGING FROM METAL DECK IS NOT PERMITTED. WHERE D. CONDUCTORS MAY BE STRANDED FOR SIZES #10 AWG AND LARGER. CONDUCTORS SIZE TEMPORARY WIRING SHALL PAY FOR ALL DAMAGE TO PROPERTY RESULTING FROM ITS USE. COMPLY INTERFERENCES OCCUR, IN ORDER TO SUPPORT CONDUIT, THE CONTRACTOR MUST INSTALL #12 AND SMALLER SHALL BE SOLID (NOT STRANDED). WITH LATEST REQUIREMENTS OF OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA). PROVIDE R. ALL PANELBOARDS ARE EXISTING TO REMAIN. SHALL BE LISTED UNDER UL 67 AND SHALL HAVE PERSONNEL GROUND FAULT PROTECTION ON ALL TEMPORARY POWER AND LIGHTING CIRCUITS 30 TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE APPROPRIATE LABELING. ALL BUSSING SHALL BE SOLID COPPER. WITH ACCESS TO FIRE DAMPERS, VALVES, JUNCTION BOXES, ACCESS DOORS, OTHER EQUIPMENT E. ON ALL 20 AMP BRANCH CIRCUITS, CONDUCTORS LARGER THAN #10 AWG SHALL BE REDUCED TO AMPERES OR LESS. GROUND FAULT CIRCUIT INTERRUPTERS ON CONSTRUCTION CIRCUITS ARE NOT REQUIRED WHERE CIRCUIT IS A PERMANENT CIRCUIT TO BE A PART OF THE COMPLETED BUILDING. SERVICE REQUIREMENTS AND/OR OTHER TRADES. HANGER TYPES AND INSTALLATION METHODS ARE#10 AWG WITHIN 10 FEET OF PANELBOARD AND DEVICES IN JUNCTION BOXES ON RATED S. PANELBOARDS FOR USE ON 480Y/277V SYSTEM SHALL HAVE A MINIMUM INTEGRATED SUBJECT TO LANDLORD CRITERIA. TERMINAL STRIPS. HOWEVER, CONTRACTOR SHALL PROVIDE APPROVED CORD SETS INCORPORATING GFCI EQUIPMENT SHORT CIRCUIT CURRENT RATING OF 14,000 AMPS RMS SYMMETRICAL. PROTECTION FOR PERSONNEL. SEE THE LOCALLY ADOPTED EDITION OF THE N.E.C. ALL FINISH PANELBOARDS FOR USE ON 208Y/120V VOLT SYSTEM SHALL HAVE A MINIMUM INTEGRATED Y. FIXTURE SUPPORTS SHALL BE IN ACCORDANCE WITH NEC ARTICLE 410.30 OR ANY LOCAL CODESF. ALUMINUM CONDUCTORS ARE PERMITTED. PAINTING IS TO BE PERFORMED BY GENERAL CONTRACTOR EXCEPT THAT THIS CONTRACTOR SHALL EQUIPMENT SHORT CIRCUIT CURRENT RATING OF 10,000 AMPS RMS SYMMETRICAL. EXACT RESTORE TO ORIGINAL CONDITION ANY PAINTING DEFACED BY THIS CONTRACTOR AFTER ORIGINALTHAT MAY APPLY. RATING SHALL BE DETERMINED BY AVAILABLE FAULT CURRENT FROM UTILITY. GENERAL G. THE FOLLOWING COLOR CODE SHALL BE USED: PAINTING. CONTRACTOR SHALL FURNISH PANELS BASED ON UTILITY COMPANY INFORMATION. ALL LUG Z. UPON COMPLETION OF THE WORK, GENERAL CONTRACTOR SHALL FURNISH TO THE ARCHITECT A CONNECTIONS SHALL BE 75 DEGREES C RATED. CERTIFICATE OF INSPECTION AND APPROVAL FROM THE ABOVE DEPARTMENT BEFORE FINAL PHASE A BLACK BROWN ELECTRICAL CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING PAYMENT ON CONTRACT WILL BE ALLOWED. PHASE B RED ORANGE REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY T. PANELBOARD FRONT ASSEMBLY SHALL INCLUDE A HINGED DOOR WITH A FLUSH MOUNTED PHASE C BLUE YELLOW TENANT'S CONSTRUCTION MANAGER AND THE LANDLORD. PATCHING IS TO BE "AS NEW CONDITION". CYLINDER LOCK TYPE SPRING LOADED LATCH. ALL LOCKS SHALL BE KEYED ALIKE. DOOR SHALL AA. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND GROUNDS BEFORE ANY EQUIPMENT IS NEUTRAL WHITE GRAY INCLUDE A TYPED CIRCUIT DIRECTORY CARD MOUNTED IN A FRAME WITH A CLEAR PLASTIC CONNECTED. WHEN DIRECTED BY ARCHITECT, DEMONSTRATE BY PROPER VOLTAGE MEGGER TEST GROUND GREEN GREEN ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, OF INSULATION RESISTANCE OF ANY CONDUCTORS AND REPLACE ALL CONDUCTORS WHICH FAIL PROTECTIVE COVER. ISOLATED GROUND GREEN/ YELLOW STRIPE GREEN/YELLOW STRIPE SERVICING, MAINTAINING AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SAID TESTS UNTIL ALL CONDUCTORS ARE FREE FROM INSULATION FAULTS. SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. U. EACH PANELBOARD SHALL HAVE A FULL CAPACITY SOLID COPPER NEUTRAL SUBASSEMBLY. H. CIRCUIT BREAKER/FUSE AND WIRE SIZE COMBINATIONS NOT SHOWN ABOVE SHALL BE APPROVED AB. ELECTRICAL LAYOUTS ARE SCHEMATIC. THE FINAL LOCATIONS OF ALL EQUIPMENT, OUTLETS, ETC. BY THE ENGINEER PRIOR TO INSTALLATION. ANY ACCESS PANELS REQUIRED, BUT NOT SPECIFIED OR SHOWN ON DRAWINGS, SHALL BE V. EACH PANELBOARD SHALL INCLUDE A SOLID COPPER GROUND BUS SUBASSEMBLY, SIMILAR IN SHALL BE SUBJECT TO REASONABLE CHANGES IN LOCATION UP TO THE TIME OF ROUGHING-IN AT FURNISHED BY GENERAL CONTRACTOR WITH DESIGN TO BE APPROVED BY ARCHITECT BEFORE CONSTRUCTION TO THE NEUTRAL SUBASSEMBLY, FACTORY MOUNTED AND BONDED TO THE BOX. NO ADDITIONAL COST TO THE OWNER. EXACT LOCATIONS ARE DETERMINED BY EXACT LOCATION OF 26 05 26 GROUNDING AND BONDING STARTING INSTALLATION. EQUIPMENT, AND MAY BE REVISED TO SUIT THE CONSTRUCTION CONDITIONS AND COORDINATION W. EACH PANELBOARD SHALL INCLUDE (WHERE SPECIFIED) A SOLID COPPER ISOLATED GROUND BUS WITH OTHER TRADES. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY SUBASSEMBLY, SIMILAR IN CONSTRUCTION TO THE NEUTRAL SUBASSEMBLY, FACTORY SUPPLIED TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING PRIOR TOA. FURNISH AND INSTALL A COMPLETE GROUNDING SYSTEM IN COMPLIANCE WITH ALL REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE. MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE TENANT'S FIELD INSTALLED. MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NORCONSTRUCTION MANAGER IN WRITING OF ANY VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO B. A SEPARATE EQUIPMENT GROUNDING CONDUCTOR, MINIMUM SIZE PER NEC TABLE 250.122, X. INTERIOR LABELING SHALL INCLUDE A CONNECTION DIAGRAM AND LABELS INDICATING PROPER CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS NECESSARY TO COMPLETE THE WORK OR SUBMISSION OF THE BID. OTHERWISE, TENANT'S CONSTRUCTION MANAGER'S INTERPRETATION OF SHALL BE INSTALLED IN CONDUIT ALONG WITH ALL FEEDERS, BRANCH CIRCUITS AND CONTROL WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION. TORQUE AND WIRE TYPES FOR MAIN INPUT CONNECTIONS AND BOTH LINE AND LOAD SIDE CIRCUITS. CONDUCTOR INSULATION SHALL BE GREEN. CONTRACT. CIRCUIT BREAKER CONNECTIONS. BRANCH CIRCUIT BREAKERS SHALL BE QUICK MAKE, QUICK AC. ELECTRICAL DRAWINGS ARE INTENDED TO INDICATE APPROXIMATE LOCATIONS OF SWITCHES, C. CONDUIT SYSTEM SHALL BE ELECTRICALLY CONTINUOUS. ALL ENCLOSURES AND NON-CURRENT BREAK, THERMAL MAGNETIC TRIP (ENCLOSURE COMPENSATED), MOLDED CASE TYPE, UL LISTED. ALL WORK SHALL BE DONE IN ACCORDANCE WITH: 15 AND 20 AMP SINGLE POLE BREAKERS SHALL CARRY THE UL "SWD" MARKING. LINE SIDE RECEPTACLES, LIGHTING FIXTURES AND OTHER ITEMS OF VARIOUS ELECTRICAL SYSTEMS OF CARRYING METALS TO BE GROUNDED. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR TERMINALS SHALL BE BOLTED TO MAIN BUSBARS. BREAKER RATINGS SHALL BE PER DRAWINGS. PROJECT. EXACT LOCATIONS AND ROUGH-IN DIMENSIONS FOR ALL WORK AND EQUIPMENT SHALL PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON-CURRENT CARRYING 1. THE NATIONAL ELECTRICAL CODE (NFPA 70). ALL BREAKERS FEEDING HVAC EQUIPMENT SHALL BE HACR RATED, UNLESS NOTED OTHERWISE. BE OBTAINED FROM ARCHITECT OR ARCHITECT'S REPRESENTATIVE AS WORK PROGRESSES. METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED 2. STATE, CITY, AND COUNTY BUILDING CODES AND ORDINANCES. SHOULD THE GENERAL CONTRACTOR FAIL TO PROPERLY OBTAIN SUCH LOCATIONS OR DIMENSIONS, CLAMPS. 3. NATIONAL BOARD OF FIRE UNDERWRITERS (NFPA 72), (NFPA 101). Y. TERMINALS FOR CONNECTION OF THE FEEDER TO THE PANELBOARD MAINS TO MAIN BREAKER THE ARCHITECT SHALL CHANGE THIS WORK AT THE GENERAL CONTRACTORS EXPENSE WHEN 4. CERTAIN CODES AND STANDARDS AS SET UP BY VARIOUS TECHNICAL SOCIETIES SUCH AS SHALL BE UL RECOGNIZED AS SUITABLE FOR THE TYPE OF CONDUCTORS SPECIFIED. REQUESTED BY ARCHITECT. ARCHITECT RESERVES THE RIGHT TO MAKE MINOR CHANGES IN D. ALL RECEPTACLES SHALL BE BONDED TO A GROUND CONDUCTOR USING A #12 AWG MINIMUM UL, NEMA, NECA, IEEE, ASTM, IES, IPCEA, AND ANSI. LOCATION OF ELECTRICAL WORK OR EQUIPMENT PRIOR TO ROUGHING IN WITH NO ADDITIONAL BONDING JUMPER BETWEEN RECEPTACLE TERMINAL AND GROUND CONDUCTOR. METAL-TO-METAL 5. THIS WORK SHALL BE GOVERNED ALSO BY LOCAL INSPECTOR'S REQUIREMENTS. COST TO TENANT. TENANT'S CONSTRUCTION MANAGER RESERVES THE RIGHT TO RELOCATE ANY CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE FOR EITHERZ. NAMEPLATES SHALL BE PROVIDED WITH DESIGNATIONS AS SCHEDULED ON DRAWINGS FOR 6. FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT STANDARDS. PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS. NAMEPLATES SHAL OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. 7. AMERICANS WITH DISABILITIES ACT. BE LAMINATED PHENOLIC WITH A WHITE SURFACE AND BLACK CORE. 26 05 00 COMMON WORK RESULTS FOR ELECTRICA L B. H G C. F D. LAYOUT: E-701 (480v) E E. D USER: SHOLLAND PLOTTED: 7/9/2015 - 12:56 PM P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\E-701_04933.dwg F. G. H. C I. B J. K. A L. AD. THE ARCHITECT RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ANY ITEM WHICH, E. BOND TRANSFORMER NEUTRAL TO A GROUNDING ELECTRODE SYSTEM. CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND IN THEIR OPINION, SHALL NOT PRESENT AN ORDERLY OR REASONABLY NEAT OR WORKMANLIKE AA. MANUFACTURER: SQUARE D TYPE NQ FOR 208Y/120V APPLICATIONS, TYPE NF FOR 480Y/277V REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID APPEARANCE, PROVIDED THAT SUCH ITEM CAN BE PROPERLY INSTALLED IN SUCH ORDERLY WAY BY APPLICATIONS. EQUAL EQUIPMENT BY GENERAL ELECTRIC, SIEMENS, OR CUTLER HAMMER WILL B F. THE GROUNDING ELECTRODE CONDUCTOR FOR SEPARATELY DERIVED SYSTEMS, SUCH AS AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE METHODS USUAL IN SUCH WORK, OR WHICH DOES NOT COMPLY WITH CONTRACT DRAWINGS OR DRY-TYPE TRANSFORMERS, SHALL BE RUN IN NON-METALLIC (PVC) CONDUIT TO MINIMIZE GROUNDACCEPTED. LINE ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SPECIFICATIONS. SUCH REMOVALS OR REPLACEMENTS SHALL BE DONE BY CONTRACTOR WHEN SO IMPEDANCE. SHALL BE REIMBURSED BY TENANT TO THE CONTRACTOR. AB. EACH PANELBOARD SHALL BE INSTALLED WITH TOP CIRCUIT BREAKER AT 6'-0" ABOVE FLOOR, DIRECTED IN WRITING BY ARCHITECT AND AT CONTRACTOR'S EXPENSE. FLUSH OR SURFACE MOUNTED. ALL FLUSH PANELBOARDS SHALL HAVE (3) 3/4" EMPTY CONDUITS G. LIGHTING FIXTURES SHALL BE GROUNDED BY THE USE OF A PIGTAIL FASTENED ON BARE METAL WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES, THE LANDLORD INSTALLED TO ABOVE ACCESSIBLE CEILING FOR FUTURE USE. AE. THE ELECTRICAL CONTRACTOR SHALL KEEP ONE SET OF WORKING DRAWINGS ON WHICH ALL THAT IS FREE OF PAINT. OR TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE DEVIATIONS, AND CHANGES FROM THE CONTRACT DOCUMENTS, AS WELL AS CONCEALED FEEDER SYSTEM WITH THE MOST STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE AC. ALL CONNECTIONS AT PANELS AND SWITCHES ARE TO BE MADE, ALL SPLICES COMPLETE, ALL ROUTINGS, SHALL BE RECORDED. THESE DRAWINGS, SHALL NOT BE USED FOR OTHER PURPOSES. H. BOND ALL STRUCTURAL STEEL TO EARTH, GROUND RODS OR PLATES, OR WATER SYSTEM. BOND DRAWINGS, UNLESS NOTED OTHERWISE. FUSES IN PLACE, AND ALL CIRCUITS CONTINUOUS FROM POINT OF SERVICE CONNECTION TO IT'S THIS SET OF WORKING DRAWINGS SHALL BE DELIVERED TO THE OWNER IN GOOD CONDITION AS A ALL ROOF MOUNTED EQUIPMENT TO ACCEPTABLE GROUNDS PER THE N.E.C. FINAL DESTINATION, AND ALL COVERS AND PLATES INSTALLED AND FINAL ELECTRICAL INSPECTIO PERMANENT RECORD OF THE INSTALLATION CONSTRUCTED. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING PRIOR TO THE TIME OF FINAL INSPECTION BY OWNER'S CONSTRUCTION MANAGER. ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED, AF. THE MATERIALS AND EQUIPMENT INSTALLED IN THE WORK SHALL MEET THE REQUIREMENTS OF THE MEET OSHA REQUIREMENTS AND SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL CONTRACT DOCUMENTS. AD. TEST AND MAKE CORRECTIONS/ADJUSTMENTS FOR PHASE BALANCING. ELECTRICAL CODE, STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. (ELECTRICAL SPECIFICATIONS CONTINUED ON SHEET E-702) AG. ELECTRICAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL BEFORE STARTING THE WORK INVOLVED PER THE DOCUMENTS PROVIDED BY THE TENANT. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 CONSULTANT PROJECT150066 # Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com SEAL AT J A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 RIVERCHASE GALLERIA A. K RIVERCHASE GALLERIA 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM SGH STORE #:4933 DRAWN BY:SRH REVIEWED BY:RAP AUTHORIZED FOR: ELECTRICAL SPECIFICATIONS 2 3 4 A. B. C. D. E. J F. G. H. I. H J. K. G L. F USER: SHOLLAND PLOTTED: 7/9/2015 - 12:56 PM P:\SGH\150066 SGH-Riverchase Galleria Birmingham, AL\E-701_04933.dwg LAYOUT: E-701 (480v) E D C B A 6 7 8 9 10 11 J. 27 00 00 GENERAL REQUIREMENTS 12 13 14 WORKSTATION: LABEL CABLES WITHIN OUTLET BOXES AND NEATLY TYPED ON THE INTEGRAL LABEL IN THE FACEPLATE WITH THE PATCH PANEL PORT NUMBER. FURNISH AND INSTALL OUTLET BOXES FOR ALL DEVICES AS REQUIRED, (RECEPTACLES, LIGHTING A. INSTALL ALL WIRING DEVICES, INCLUDING SWITCHES, RECEPTACLES AND POWER RECEPTACLES, A. PROVIDE ALL MATERIALS, LABOR, TOOLS, TRANSPORTATION INCIDENTALS AND APPURTENANCES FIXTURES, MOTORS, SYSTEMS EQUIPMENT CONNECTIONS, SPECIAL OUTLETS AND AS OTHERWISE K. WARRANTY PERIOD FOR COMMUNICATIONS CONNECTIVITY (INCLUDING ALL COPPER): TELEPHONE OUTLET BOXES, COVER PLATES AND BLANK OUTLET PLATES AS SHOWN OR DESCRIBED TO COMPLETE IN EVERY DETAIL AND LEAVE IN WORKING ORDER ALL WORK CALLED FOR HEREIN. REQUIRED). MANUFACTURER'S STANDARD, BUT NOT LESS THAN 25 YEARS FROM DATE OF CONTRACT ON DRAWINGS. COMPLETION. B. ALL NEW MATERIAL AND EQUIPMENT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING ALL OUTLET BOXES SHALL BE GALVANIZED PRESSED STEEL, NOT LESS THAN 14 GAUGE IN B. UNLESS OTHERWISE NOTED ON DRAWINGS OR OTHERWISE REQUIRED BY THE NATIONAL STANDARDS: THICKNESS, OF THE STANDARD KNOCKOUT TYPE. NO ROUND OUTLET BOXES SHALL BE PERMITTED, 23 31 11 DIGITAL ADDRESSABLE FIRE ALARM SYSTEM. 1. TELECOMMUNICATIONS INDUSTRY ASSOC./ELECTRONIC INDUSTRIES ALLIANCE (TIA/EIA): EXCEPT AS SPECIFICALLY NOTED ON DRAWINGS. CONCEALED BOXES SHALL NOT BE LESS THAN 4" ELECTRICAL CODE, ACCESSIBILITY CODES OR LOCAL CODES, OUTLET HEIGHTS SHALL BE AS FOLLOWS: a. TIA/EIA 568A.1, 2, AND 3 TELECOMMUNICATION CABLING STANDARD. SQUARE AND 1-1/2" DEEP, WITH PLASTER RINGS. A. EXISTING FIRE ALARM SYSTEM TO REMAIN, SHALL BE UNDER A SEPARATE PERMIT. ALL REQUIRED b. TIA/EIA 569 TELECOMMUNICATION PATHWAYS AND SPACES. FIRE ALARM DEVICES, CONDUITS, WIRES, BACKBOXES, ETC. SHALL BE INSTALLED AT TENANT'S 1. SWITCH HEIGHT 48" FROM FINISHED FLOOR TO CENTERLINE OF OUTLET. c. TIA/EIA 606 ADMINISTRATION OF INFRASTRUCTURE ALL KNOCKOUT BOXES, UPON WHICH LIGHTING FIXTURES ARE TO BE INSTALLED, SHALL BE EXPENSE UNDER A SEPARATE PERMIT BY MALL FIRE/LIFE SAFETY CONTRACTOR. INDICATE ON PLAN 2. TELEPHONE OUTLETS SHALL BE LOCATED AS NOTED ON DRAWINGS. d. TIA/EIA 607 GROUNDING AND BONDING EQUIPPED WITH 3/8" FIXTURE STUDS. THAT IS REQUIRED, A VARIANCE WILL BE PROVIDED. e. COMPLY WITH TIA/EIA 568, 569, AND BIC STANDARDS. f. COMPLY WITH NFPA 70. RECESSED OUTLET BOXES SHALL BE STAMPED STEEL SUITABLE FOR THE DEVICE INSTALLED. C. DUPLEX RECEPTACLES SHALL BE GROUNDING TYPE, NEMA 5-20R, RATED FOR A 20 AMPS, 125 SURFACE MOUNTED OUTLET BOXES SHALL BE CAST IRON SUITABLE FOR THE DEVICE INSTALLED. VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING.GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLES SHALL BE PROVIDED WHERE INDICATED. C. THE CONTRACTOR SHALL BEAR ALL COSTS OF PERMITS, INSPECTIONS TESTS, AND/OR APPROVALS. EXTERIOR BOXES SHALL BE CAST ALUMINUM TYPE WITH GASKETED DEVICE COVERS TO SUIT. D. SWITCHES SHALL BE TOGGLE OPERATED, QUIET TYPE, RATED FOR 20 AMPS, 120/277 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. THREE WAY AND FOUR WAY SWITCHES SHALL BE D. THE CONTRACTOR SHALL PROVIDE ON-SITE PERSONNEL TO TROUBLESHOOT AND REPAIR ANY PROVIDED WHERE INDICATED. PROBLEMS THAT ARISE DURING CUTOVER AS THEY RELATE TO THEIR INSTALLED SYSTEM. INSTALL BOXES RIGIDLY FROM BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE BOX EXTENSIONS TO EXTEND BOXES TO FINISHEDE. DIMMERS SHALL BE LUTRON "NOVA T-STAR" SERIES, OF A RATING, VOLTAGE AND WATTAGE SUITABLE FOR LOAD SERVED. E. AFTER COMPLETION, A WARRANTY SHALL BE FURNISHED FOR ALL COMPONENTS, PARTS, AND FACES OF FLOORS, CEILINGS, WALLS ETC. ALL OUTLET BOXES TO BE PROVIDED WITH CADDY F. COLORS OF DEVICES SHALL MATCH WALL. ASSEMBLIES AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. WARRANTY SERVICES SHALL "QUICK-MOUNT BOX SUPPORT" TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN G. WIRING DEVICES SHALL BE SPECIFICATION GRADE, AS MANUFACTURED BY HUBBELL, PASS & BE PROVIDED BY A CERTIFIED, FACTORY TRAINED REPRESENTATIVE OF THE EQUIPMENT PLUGGING/UNPLUGGING INTO THESE DEVICES. SEYMOUR, ARROW HART, LEVITON AND GENERAL ELECTRIC. MANUFACTURER FOR A MINIMUM OF ONE YEAR OR AS SPECIFIED IN EACH INDIVIDUAL SECTION. ALL ELECTRICAL CONDUCTORS SHALL BE ENCLOSED IN CONTINUOUS GROUNDED RACEWAY H. FLOOR RECEPTACLES SHALL BE HUBBELL "SYSTEMONE" SERIES FOR FLUSH FLOOR APPLICATIONS. 27 05 10 TELEPHONE AND DATA CONDUIT SYSTEM SYSTEM EXCEPT AS OTHERWISE NOTED (I.E. LOW-VOLTAGE PLENUM-RATED WIRE). a. FLOOR BOX - MODEL S1PFB NON-METALLIC ROUND FLOOR BOX A. FURNISH AND INSTALL A SYSTEM OF CONDUIT RACEWAYS, OUTLET BOXES, PULL WIRES, AND b. POKE-THRU - MODEL S1PTFIT THRU-FLOOR FITTING (DUAL CHANNEL) NO OTHER CIRCUITS ARE TO BE RUN IN SAME CONDUIT FEEDING ISOLATED GROUND RECEPTACLES. TERMINAL BOARDS AS SHOWN ON THE DRAWINGS UNLESS OTHERWISE NOTED ON PLANS. c. SUB PLATE - MODEL S1SP SUB-PLATE(STYLE LINE/GFCI) TELEPHONE SWITCHING APPARATUS, CONDUCTORS, INSTRUMENTS, MISCELLANEOUS EQUIPMENT RACEWAY AND ENCLOSURE SIZES SHALL BE AS SHOWN ON DRAWINGS OR, IF NOT SHOWN, SHALL d. COVER - MODEL S1TFCAL (ALUMINUM FINISH). AND APPURTENANCES ARE NOT PART OF THIS CONTRACT AND WILL BE PROVIDED AND INSTALLED BE SIZED TO COMPLY WITH N.E.C. FILL REQUIREMENTS FOR CONDUCTORS ENCLOSED. OTHER EQUIVALENT DEVICES WITH MATCHING COVER PLATES MAY BE FURNISHED AS APPROVED BY OTHERS. PULL OR JUNCTION BOXES SHALL BE PROVIDED IN ALL RACEWAY SYSTEMS AT MAXIMUM OF 100 BY OWNER'S. B. CONDUITS FOR TELEPHONE WALL OUTLETS AND DATA WIRING SHALL BE A MINIMUM OF 1" UNLESS FOOT INTERVALS AND WHERE REQUIRED TO AVOID EXCESSIVE NUMBER OF BENDS, TO FACILITATE WIRE PULLING OR TO PROVIDE ACCESS TO RACEWAY SYSTEM. BOXES AND COVERS SHALL BE I. WIRING DEVICES, UNLESS OTHERWISE PROPERLY AUTHORIZED, SHALL BE SAME MANUFACTURERSNOTED OTHERWISE. GALVANIZED STEEL OF CODE GAUGE SIZE. TO THE EXTENT POSSIBLE, AVOID THE USE OF JUNCTION ONLY; NO ADDITIONAL MANUFACTURERS SHALL BE PERMITTED UNLESS SPECIFICALLY C. FURNISH AND INSTALL A 3/4" THICK, FIRE-TREATED, PLYWOOD TELECOM BACKBOARD AT LOCATION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS AUTHORIZED BY TENANT OR TENANT'S REPRESENTATIVE. SHOWN ON THE DRAWINGS. PAINT WITH FIRE RETARDANT "P-1B" OR AS DIRECTED BY TENANT'S SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR CONSTRUCTION MANAGER. THE PLYWOOD BACKBOARD SHALL BE SECURELY ATTACHED TO THE GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. JUNCTION AND PULL BOXES MUST BE J. LOW VOLTAGE CONTROL DEVICES SHALL BE AS NOTED ON DRAWINGS OR AS REQUIRED. BUILDING WALLS TO SUPPORT RELAY PANELS, TERMINAL BLOCKS AND OTHER HARDWARE WEIGHING LABELED WITH CIRCUIT NUMBER IDENTIFICATION AND SYSTEM TYPE ON COVER. APPROXIMATELY 10 POUNDS PER SQUARE FOOT. 26 29 13 MOTOR CONTROLLERS RACEWAYS AND ENCLOSURES SHALL BE ADEQUATELY SUPPORTED FROM BUILDING STRUCTURE D. ALL CONDUIT RUNS FOR DATA AND TELEPHONE SHALL BE CONTINUOUS WITH NO JUNCTION BOXES WITH APPROVED SUPPORT RODS AND/OR CLAMPS IN ACCORDANCE WITH ARTICLE 300.7 OF THE A. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL MOTOR CONTROLS, INCLUDING EXCEPT AS NOTED ON DRAWINGS. THIS INCLUDES BUT IS NOT LIMITED TO RUNS BETWEEN NATIONAL ELECTRIC CODE. STARTERS, SAFETY DEVICES AND REMOTE CONTROL STATIONS, UNLESS FURNISHED BY TELEPHONE BOARD, MANAGER'S OFFICE, SOUND SYSTEM, CASHWRAPS AND TELEPHONE SETS. EQUIPMENT MANUFACTURER IN PRE-WIRED ASSEMBLIES. ALL CONDUIT SHALL BE RIGID HEAVYWALL GALVANIZED STEEL OR THIN WALL EMT WHERE PERMITTED E. INSTALL PULL STRING IN EMPTY CONDUITS. ALL CONDUITS SHALL BE LABELED FOR PURPOSE BY CODE OR AS HEREINAFTER SPECIFIED. PVC SCHEDULE 80 CONDUIT MAY BE USED UNDER B. FURNISH AND INSTALL MANUAL MOTOR STARTERS WITH OVERLOAD RELAYS IN EACH LINE DESIGNATED. FLOOR SLAB. ROMEX, BX OR AC, ETC., ARE NOT PERMITTED. CONDUCTOR FOR ALL FRACTIONAL HORSEPOWER MOTORS NOT EQUIPPED WITH BUILT-IN RUNNING OVERCURRENT PROTECTION, NOT REQUIRING AUTOMATIC CONTROLLERS. F. FURNISH AND INSTALL GROUND ROD AND #6 GROUND WIRE FROM TELECOM BACKBOARD TO M. MINIMUM SIZE OF CONDUIT SHALL BE 1/2" FOR INDIVIDUAL LIGHTING FIXTURE CONNECTIONS OR TO INDIVIDUAL LIGHT SWITCHES (IF ACCEPTABLE BY THE LANDLORD AND LOCAL CODE OFFICIALS) C. MANUAL MOTOR STARTERS SHALL INCLUDE OVERLOAD RELAYS IN ALL LINE POLES SIZED TO TRIP SERVICE ENTRANCE GROUND AND GROUND ROD PER TELEPHONE COMPANY'S REQUIREMENTS. AND 3/4" FOR ALL OTHER LOCATIONS. IF HVAC CONTROL WIRING IS REQUIRED TO BE RUN IN SWITCH AT 125% OF MOTOR FULL LOAD RUNNING CURRENT, NEON PILOT LIGHTS, AND NEMA G. OUTLET BOXES TO BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. CONDUIT, IT SHALL BE A MINIMUM OF 1/2", UNLESS NOTED OTHERWISE ON DRAWINGS. ALL ENCLOSURES, AS MANUFACTURED BY SQUARE-D, GENERAL ELECTRIC, ALLEN BRADLEY, SIEMEN'S IN/UNDER FLOOR CONDUIT SHALL BE OF MINIMUM 1" SIZE. OR CUTLER HAMMER. 27 05 15 INTERIOR COMMUNICATIONS PATHWAYS N. EMT THIN WALL CONDUIT MAY BE USED INSIDE HOLLOW PARTITIONS, AND ABOVE SUSPENDED D. FURNISH AND INSTALL AUTOMATIC MOTOR STARTERS FOR ONE (1) HP OR LARGER SINGLE PHASE A. INTERIOR COMMUNICATIONS PATHWAYS SHALL BE INSTALLED BY THE GENERAL CONTRACTOR AND CEILINGS AND EXPOSED ABOVE 8'-0" ABOVE FINISHED FLOOR OR ABOVE PANELBOARDS. EMT AND THREE PHASE MOTORS OR MOTORIZED EQUIPMENT FURNISHED WITHOUT STARTERS, BY THE TELECOMMUNICATIONS CONTRACTOR AS SPECIFIED HEREIN. CONDUIT MAY NOT BE USED BURIED IN EARTH OR FILL, IN OR UNDER CONCRETE FLOOR OR IN REQUIRINGAUTOMATIC STARTERS FOR CONTROL REGARDLESS OF HORSEPOWER RATING. ALL POURED CONCRETE CONSTRUCTION. THREE PHASE STARTERS SHALL HAVE ANTI-SINGLE PHASING, UNDERVOLTAGE PROTECTION, AND B. CONDUITS SHALL BE INSTALLED, AS DETAILED IN DRAWINGS. THESE CONDUITS SHALL BE PHASE REVERSAL PROTECTION RELAYS EITHER INCLUDED IN STARTERS OR WIRED TO STARTER INSTALLED BY THE GENERAL CONTRACTOR. O. PVC CONDUIT USED UNDER FLOOR SLABS SHALL HAVE RIGID GALVANIZED STEEL ELLS AND CONTROL CIRCUIT. METALLIC CONDUIT ABOVE FLOOR SLAB. E. PROTECTIVE RELAYS SHALL HAVE ADJUSTABLE TIME DELAY RELAY IN CIRCUIT TO AVOID NUISANCE 27 11 00 HORIZONTAL CABLING AND CONNECTIVITY P. FLEXIBLE METAL CONDUIT (FMC) SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK ANDSHUT DOWNS. TIME MARK OR SIMILAR EQUIPMENT IS ACCEPTABLE, IF PROTECTION IS NOT PART A. PROVIDE A 10/100/1000 MBPS FULL-DUPLEX TRANSMISSION ETHERNET NETWORK OVER 4-PAIR, AS THE FINAL CONNECTION TO RECESSED FIXTURES, MOTORS, AND ELECTRICAL EQUIPMENT THATOF STARTER. DO NOT RELY ON PROPERLY SIZED FUSES AND MOTOR STARTER OVERLOAD HEATERS CATEGORY 5E UTP HORIZONTAL CABLING. THE SYSTEM SHALL BE A CERTIFIED SOLUTION BY THE MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. FMC SHALL BE UL APPROVED, AND ALONE TO AVOID SINGLE PHASING BURNOUTS. CONNECTIVITY MANUFACTURER. THE HORIZONTAL INFRASTRUCTURE SHALL SUPPORT BOTH VOICE BOTH THE CONDUIT AND FITTINGS SHALL BE LISTED FOR GROUNDING. FMC SHALL BE KEPT TO F. SIX FURNISH AND INSTALL CONTACTORS, CONTROL RELAYS, PUSHBUTTON STATIONS, SELECTOR AND DATA APPLICATIONS. FEET (6'-0") MAXIMUM LENGTH AND SHALL BE MINIMUM ONE-HALF INCH (1/2") ELECTRICAL TRADE SWITCHES, PILOT LIGHTS, FUSES AND SIMILAR CONTROL AUXILIARIES AS SHOWN ON DRAWINGS AND/OR REQUIRED TO PROVIDE PROPER CONTROL AND ISOLATION BETWEEN VARIOUS AUTOMATIC SIZE. WHEN CONNECTED TO HARD CONDUIT, THE FMC MUST BE THE SAME SIZE AS THE HARD B. THIS SECTION INCLUDES WIRE, CABLE, CONNECTING DEVICES, INSTALLATION, AND TESTING FOR CONTROLLERS AND EQUIPMENT SHOWN ON THE DRAWINGS. CONDUIT IT IS CONNECTED TO. AN EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED IN WIRING SYSTEMS TO BE USED AS SIGNAL PATHWAYS FOR VOICE, VIDEO, AND DATA ALL RUNS OF FMC. TRANSMISSION. THE SYSTEM SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: G. ALL CIRCUIT BREAKERS FEEDING MOTOR LOADS SHALL BE HACR TYPE. 1. MOUNTING ELEMENTS Q. LIQUID-TIGHT FLEXIBLE METAL CONDUIT (LFMC) AND LIQUID-TIGHT FITTINGS SHALL BE USED IN 2. UNSHIELDED TWISTED-PAIR CABLE. AREAS EXPOSED TO THE WEATHER OR EXCESSIVE MOISTURE AS THE FINAL CONNECTION TO H. EQUIPMENT SHALL BE SAME MAKE AS MOTOR STARTERS. PUSHBUTTON STATIONS, SELECTOR 3. PATCH, STATION, AND CROSS CONNECT CORDS MOTORS, AND ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SWITCHES, PILOT LIGHTS: HEAVY DUTY, OIL TIGHT, STANDARD SIZE, WITH TRANSFORMER TYPE 4. JACKS AND FACEPLATES SYSTEM. LFMC SHALL BE UL APPROVED, AND BOTH THE CONDUIT AND FITTINGS SHALL BE LISTED PILOT LIGHTS, FLUSH MOUNTED WHERE PRACTICAL. 5. TERMINATION AND PATCH PANELS FOR GROUNDING. LFMC SHALL BE KEPT TO SIX FEET (6'-0") MAXIMUM LENGTH AND SHALL BE I. ALL OVERLOAD DEVICES, INCLUDING EQUIPMENT FURNISHED UNDER OTHER CONTRACTS, SHALL BE MINIMUM ONE-HALF INCH (1/2") ELECTRICAL TRADE SIZE. WHEN CONNECTED TO HARD CONDUIT, C. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE THE LFMC MUST BE THE SAME SIZE AS THE HARD CONDUIT IT IS CONNECTED TO. AN EQUIPMENT SET AND ADJUSTED TO SUIT THE LOAD CONDITIONS. OF THE FOLLOWING: GROUNDING CONDUCTOR MUST BE INSTALLED IN ALL RUNS OF LFMC. 1. COPPER CABLES (UTP): 26 51 00 INTERIOR LIGHTING a. BERK-TEK, INC. R. ALL CONDUIT IN EXPOSED AREAS SHALL BE CONCEALED. CONDUIT SMALLER THAN 3/4' SHALL NOT A. INSTALL LIGHTING FIXTURES SPECIFIED ON THE FIXTURE SCHEDULE AND SHOWN ON THE DRAWINGS. b. BELDEN BE USED FOR ANY CIRCUIT HOMERUN. NO CONDUIT SHALL BE RUN IN SLAB, EXCEPT AS REQUIRED c. MOHAWK FOR FLOOR-MOUNTED DEVICES. PROVIDE PROPERLY LABELED PULL STRING IN ALL EMPTY B. ALL FIXTURES TO BE LISTED AND LABELED BY UNDERWRITERS LABORATORIES AND ALL BALLASTS d. GENERAL CONDUITS. TO BE CBM CERTIFIED BY ETL. e. UNIPRISE 2. MODULAR JACKS & FACEPLATES: S. EXPOSED CONDUIT WILL BE PERMITTED IN ELECTRIC ROOMS, AND SIMILAR UNFINISHED SPACES, C. EMERGENCY LIGHTING AS INDICATED, SHALL PROVIDE A MINIMUM OF ONE FOOT-CANDLE ALONG a. LEVITON OVERHEAD IN AREAS WITHOUT CEILINGS AND ELSEWHERE AT THE DISCRETION OF THE ARCHITECT. THE PATH OF EGRESS. FIXTURE SUPPLIER SHALL PROVIDE FOOT-CANDLE PRINTOUT TO VERIFY b. HUBBELL EMERGENCY LIGHT LEVELS. c. ORTRONICS T. ALL CONDUIT FITTINGS SHALL BE GALVANIZED MALLEABLE IRON OR STEEL. CONNECTORS AND d. PANDUIT COUPLINGS SHALL BE THREADED OR CUPPED SET SCREW TYPE, CONCRETE TIGHT. CONDUIT D. FIXTURES ARE TO BE PROVIDED COMPLETE WITH BALLASTS, SOCKET, LAMPS, END AND TRIP e. UNIPRISE BODIES SHALL BE MALLEABLE IRON, THREADED FOR HEAVYWALL CONDUIT AND CUPPED SET PLATES AND ALL MOUNTING ACCESSORIES REQUIRED FOR A COMPLETE FIXTURE INSTALLATION. SCREW TYPE FOR EMT, WITH CADMIUM FINISH AND CADMIUM PLATED SHEET STEEL COVERS. D. HORIZONTAL CABLES FOR VOICE/DATA/VIDEO INFRASTRUCTURE: SYNTHETIC RUBBER GASKETS SHALL BE USED UNDER BODY COVERS EXPOSED TO WEATHER. EMT E. INCANDESCENT AND HIGH INTENSITY DISCHARGE RECESSED LIGHTING FIXTURES TO BE FURNISHED CONNECTORS SHALL BE INSULATED THROAT TYPE. 1. LISTED AS COMPLYING WITH CATEGORY 5E OF TIA/EIA-568-A. WITH THERMAL CUT OUTS AS REQUIRED BY THE NEC. 2. CONDUCTORS: SOLID COPPER. U. INSTALL EXPANSION FITTINGS AT ALL LOCATIONS WHERE CONDUITS CROSS BUILDING EXPANSION 3. UTP CABLE: COMPLY WITH TIA/EIA-568-A. FOUR THERMOPLASTIC-INSULATED, INDIVIDUALLY F. BALLASTS SHALL BE INSTANT-START, ELECTRONIC TYPE, CLASS P, "A" SOUND RATING AND JOINTS OR TRAVERSE FROM ONE INDEPENDENT STRUCTURE TO ANOTHER. INSTALL WHEREVER TWISTED PAIR OF CONDUCTORS; NO. 2 AWG, COLOR-CODED; ENCLOSE IN A JACKET. MAXIMUM HARMONIC CONTENT OF 10%. DIMMING BALLASTS SHALL BE 3-WIRE TYPE, WITH CONDUITS TRAVERSE STRUCTURES HAVING SEPARATE FOUNDATIONS OR WHERE EXISTING 4. CABLE RATING: PLENUM - LISTED FOR USE IN AIR-HANDLING SPACES, DIMMING CAPABILITY TO 10% OF FULL RATED OUTPUT. UNLESS NOTED OTHERWISE. FURNISH BUILDINGS ARE JOINED TO A NEW STRUCTURE. 5. NON-PLENUM IN ALL OTHER AREAS. SPECIAL LOW TEMPERATURE BALLASTS FOR EXTERIOR MOUNTED FIXTURES. 6. COLOR CODING: BLUE FOR DATA, YELLOW FOR VOICE AND WHITE FOR VIDEO V. DURING ROUGHING-IN, CAP ALL CONDUITS WHICH MAY BECOME FOULED WITH FOREIGN MATERIAL. G. FLUORESCENT LAMPS SHALL BE 3500k. INCANDESCENT LAMPS SHALL BE 130 VOLT. HIGH E. WORKSTATION OUTLETS: SINGLE JACK CONNECTOR ASSEMBLIES MOUNTED IN FACEPLATE. W. NO MORE THAN THREE (3) 90 DEGREE BENDS WILL BE ALLOWED IN ANY ONE CONDUIT RUN. WHEREINTENSITY DISCHARGE LAMPS SHALL BE COATED. 3 4 5 6 7 8 9 10 11 Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com SEAL 2000 RIVERCHASE GALLERIA BIRMINGHAM, AL 35244 SPACE #236A 2.0 TYPE: PREMIUM SGH STORE #:4933 DRAWN BY:SRH REVIEWED BY:RAP AUTHORIZED FOR: ELECTRICAL SPECIFICATIONS PATCH PANEL PORT NUMBER. LABEL EACH CABLE WITHIN 3 INCHES OF EACH TERMINATION, WHERE IT IS ACCESSIBLE IN A CABINET OR JUNCTION OR OUTLET BOX, AND ELSEWHERE AS INDICATED. 2 CONSULTANT PROJECT150066 # RIVERCHASE GALLERIA MORE BENDS ARE NECESSARY IN ANY SINGLE RUN, A PULL BOX SHALL BE INSTALLED. ALL CONDUIT 1. FACEPLATE: HIGH IMPACT PLASTIC; COLOR TO BE WHITE. H. ALL RECESSED HID FIXTURES SHALL CARRY A ULR LISTING. THEY SHALL HAVE A THERMAL CUT OUT EXCEPT IN CONCRETE SLAB OR EARTH SHALL BE ROUTED PARALLEL OR PERPENDICULAR TO THE 2. MOUNTING: FLUSH, UNLESS OTHERWISE INDICATED. ON BOTH THE BALLAST AND THE FIXTURE ITSELF. LINES OF THE BUILDING, AND NO OUT-OF-PLUMB OR DIAGONAL LINES WILL BE ACCEPTED. 3. LABELING: SHALL HAVE INTEGRAL LABEL WITH LABEL COVER. 4. JACK SPACES: AS INDICATED ON THE DRAWINGS WITH ANY NECESSARY BLANKS. I. USE STEEL WIRE HANGERS FASTENED TO THE BUILDING STRUCTURE TO SUPPORT RECESSED 26 09 23 LIGHTING CONTROLS BLANKS SHALL MATCH FACEPLATE COVER. FIXTURES AT EACH CORNER. (FOUR CORNER SUSPENDED). FIXTURES TO FIT TIGHT AGAINST A. WHERE LIGHTING CONTACTORS ARE INDICATED ON THE DRAWINGS, THEY WILL BE FURNISHED ANDCONSTRUCTION TO ELIMINATE LIGHT LEAKS. F. WIRING METHOD: INSTALL HORIZONTAL CABLING IN RACEWAY WITHIN RACKS AND ENCLOSURES, INSTALLED BY ELECTRICAL CONTRACTOR COMPLETE WITH CONDUIT. THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE TO INSTALL THE CONTACTORS AND PULL ALL WIRES AS DETAILED ON THESE J. WALL-MOUNTED FIXTURES SHALL BE MOUNTED PLUMB WITH BUILDING LINES AND INSTALLED WITHAND EXCEPT IN ACCESSIBLE CEILING SPACES AND IN GYPSUM BOARD PARTITIONS WHERE CABLE WIRING METHOD MAY BE USED. CONCEAL RACEWAY AND CABLING EXCEPT IN UNFINISHED SPACES. DRAWINGS AND CIRCUITED EXACTLY AS DIAGRAMMED ON THE ELECTRICAL DETAIL DRAWINGS. NO PROPER BOX AND COVER HARDWARE. IN ACCESSIBLE CEILINGS, USE APPROPRIATELY SIZED J-HOOKS TO SUPPORT THE CABLING EVERY VARIATIONS TO THE CIRCUITING ARE ALLOWED. K. SURFACE-MOUNTED FIXTURES SHALL COVER MOUNTING HARDWARE. USE A CANOPY THAT IS NO FOUR FEET (MAXIMUM). 26 22 00 LOW VOLTAGE TRANSFORMERS LONGER THAN THE LENGTH AND WIDTH OF THE FIXTURE AND AT A HEIGHT THAT IS NO HIGHER THAN G. INSTALL CABLE USING TECHNIQUES, PRACTICES, AND METHODS THAT ARE CONSISTENT WITH REQUIRED TO MOUNT FIXTURE ABSOLUTELY VERTICAL. CANOPY FINISH SHALL MATCH FIXTURE A. DRY TYPE DISTRIBUTION TRANSFORMER IS EXISTING TO BE RELOCATED. CATEGORY 5E RATING OF COMPONENTS AND THAT INSURE CATEGORY 5E PERFORMANCE OF FINISH. COMPLETED AND LINKED SIGNAL PATHS, END TO END. B. THIS CONTRACTOR IS TO BALANCE THE VOLTAGE LEAVING THE STEP-DOWN TRANSFORMER TO PROVIDE A SECONDARY VOLTAGE OF 120 MINIMUM TO 125 VOLTS MAXIMUM BY ADJUSTING THEL. STEM-MOUNTED FIXTURES SHALL BE MOUNTED SO AS TO BE ABSOLUTELY VERTICAL AND H. DO NOT BEND CABLE IN HANDLING OR IN INSTALLING TO SMALLER RADII THAN MINIMUMS TRANSFORMER TAPS ONCE ALL THE FINAL CONNECTIONS HAVE BEEN MADE TO THE LOW VOLTAGEHORIZONTAL. INSTALL AND SUPPORT AS SHOWN ON DRAWINGS. RECOMMENDED BY MANUFACTURER. PANELBOARD. PROVIDE FINAL BALANCE REPORT TO OWNER'S CONSTRUCTION MANAGER AT TIME OF PUNCH-OUT. I. HORIZONTAL CABLES: LABEL CABLES AT THE WORK AREA END AND AT THE CLOSET END WITH THE 1 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 AT K 5 26 27 26 WIRING DEVICES RIVERCHASE GALLERIA 1 26 05 33 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS 12 13 14