Model GT 1175 Standard Slide Doors **with U30 Control
Transcription
Model GT 1175 Standard Slide Doors **with U30 Control
S82 W18717 Gemini Drive Muskego, Wisconsin 53150 Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com Technical Support: (866) 622-8325 Model GT 1175 Standard Slide Doors **with U30 Control** Installation Manual DN0079 WARNING • Turn OFF all power to the Automatic Door if a Safety System is not working. • Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained technician. Failure to follow these practices may result in serious consequences. • NEVER leave a Door operating without all Safety detection systems operational. Part #15-9244-30 Rev. 10/27/15 THIS PAGE IS INTENTIONALLY LEFT BLANK www.NabcoEntrances.com Rev. 10-27-15 1175 Standard Slide Doors Installation Manual Part #15-9244-30 Table of Contents Warning Labels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii General Safety Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv CHAPTER 1: SCOPE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Section 1a: To the Installer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Section 1b: Objective. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 CHAPTER 2: GETTING STARTED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Section 2a: Parts of the Header . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Section 2b: Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Section 2c: U30 Microprocessor Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Section 2d: Associated Manuals Part Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Section 2e: Header Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Section 2f: Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Section 2g: Holding Beams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Section 2h: Electric Lock (Optional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Section 2i: Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 CHAPTER 3: ASSEMBLE FRAME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8 Section 3a: Prepare to Assemble Door Frame. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8 Section 3b: Assemble Door Frame (No Transom). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 Section 3c: Assemble Door Frame (with Transom). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10 CHAPTER 4: SECURE FRAME TO BUILDING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Section 4a: Secure door Frame to Building. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Section 4b: Complete the Tie Rod Installation (For Transom Units only) . . . . . . . . . . . . . . . . . . . . . 4-16 CHAPTER 5: 120 VAC GENERAL WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17 CHAPTER 6: WIRE THE SWITCH ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-18 CHAPTER 7: LAY DOWN THE THRESHOLD (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . 7-19 CHAPTER 8: INSTALL THE SIDELITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-21 Section 8a: Full Open Sidelite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-21 i 1175 Standard Slide Doors Installation Manual Part #15-9244-30 www.NabcoEntrances.com Rev. 10-27-15 CHAPTER 9: INSTALL THE SLIDE DOOR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-26 Section 9e: Permanently install the Threshold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-30 Section 9f: Threshold Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-30 CHAPTER 10: INSTALL THE WEATHERING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-31 Section 10a: Apply Caulking Bead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-31 CHAPTER 11: INSTALL THE GLASS STOPS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-32 Section 11a: Door Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-32 Section 11b: Transom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-32 Section 11c: Dust Protector Hoods (Clean Room). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-33 CHAPTER 12: ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-35 Section 12a: Adjust Preload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-35 CHAPTER 13: ELECTRIC LOCK WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-38 Section 13a: U30 with Magnetic Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-38 Section 13b: U30 with Fail Secure Electric Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-39 Section 13c: U30 with Fail Safe Electric Lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-40 Section 13d: Strike Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-41 CHAPTER 14: GENERAL WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-42 CHAPTER 15: HANDING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-48 ii www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-27-15 Part #15-9244-30 WARNING LABELS Warning labels are universal and used to alert an individual of potential harm to one’s self or to others. The following warning labels are listed in a hierarchy order that defines the most potential danger first, and the least potential danger last. Please refer to this page in the event that a warning label is displayed within this manual and further definition needs to be explained. DANGER Indicates potentially dangerous situations. Danger is used when there is a hazardous situation where there is a high probability of severe injury or death. It should not be considered for property damage unless personal injury risk is present. WARNING Indicates a hazardous situation which has some probability of severe injury. It should not be considered for property damage unless personal injury risk is present. CAUTION Indicates a hazardous situation which may result in a minor injury. Caution should not be used when there is a possibility of serious injury. Caution should not be considered for property damage accidents unless a personal injury risk is present. Attention: A situation where material could be damaged or the function impaired. Notice: Indicates a statement of company policy as the message relates to the personal safety or protection of property. Notice should not be used when there is a hazardous situation or personal risk. Note: Indicates important information that provides further instruction. iii 1175 Standard Slide Doors Installation Manual Part #15-9244-30 www.NabcoEntrances.com Rev. 10-27-15 GENERAL SAFETY RECOMMENDATIONS WARNING Read this “General Safety Recommendations” section before installing, operating or servicing the automatic door. Failure to follow these practices may result in serious consequences. Notice: Read, study and understand the operating instructions contained in, or referenced in this manual before operating. If you do not understand the instruction, ask the installing qualified technician to teach you how to use the door. WARNING Do not install, operate or service this product unless you have read and understand the General Safety Recommendations, Warning Labels, Installation and Operating Instructions contained in this manual. Failure to do so may result in bodily injury, or property damage. Notice: This manual and the owner’s manual must be given to and retained by the purchasing facility or end user. ►►If the door appears broken or does not seem to work correctly, it should be immediately removed from service until repairs can be carried out or a qualified service technician is contacted for corrective action. ►►Disconnect power at the fused disconnect during all electrical or mechanical service. When uncertain whether power supply is disconnected, always verify using a voltmeter. ►►All electrical troublshooting or service must be performed by qualified electrical technicians and must comply with all applicable governing agency codes. ►►It is the responsibility of the installing door technician to install all warning and instructional labels in accordance with ANSI 156.10. ►►It is the responsibility of the purchasing facility or end user to keep warning and instructional labels and literature legible, intact and with the door. DANGER iv ►►Replacement labels and literature may be obtained from local NABCO Entrances, Inc. distributors. If the name of the local distrubutor is unknown, contact NABCO Entrances, Inc. at 1-877-622-2694 for assistance. Do not place finger or uninsulated tools inside the electrical controller. Touching wires or other parts inside the enclosure may cause electrical shock, serious injury or death. www.NabcoEntrances.com Rev. 10-27-15 1175 Standard Slide Doors Installation Manual Part #15-9244-30 CHAPTER 1: SCOPE Section 1a: To the Installer The purpose of this manual is to familiarize the installer and purchaser with the proper installation and operation of this system. It is essential that this equipment be properly installed and operational before the door is used by the public. It is the installer’s responsibility to inspect the operation of the entrance system to be sure it complies with any applicable standards. In the United States, ANSI Standard 156.10 covers the GT-1175 Slide Door System. Other local standards or codes may apply. Use them in addition to the ANSI standard. The GT-1175 is listed with the Underwriters Laboratory and is identified as such on the label. Instruct the building owners and operator on the essentials of the operation of the door and this device. The owner should follow these instructions to determine whether the door is operating properly and should immediately call for service if there is any malfunction. All installation changes and adjustments must be made by qualified, NABCO trained technicians. Section 1b: Objective The GT-1175 Standard Slide Door system is designed to be installed within a Rough Opening of a Building. The door function is controlled by the U30 Microprocessor Control. This control offers many features to accommodate most installation options. This manual offers step by step instructions. Scope 1-5 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 CHAPTER 2: GETTING STARTED ►►Manufactured out of: • Aluminum • Opening of Building • Bi-Part: (2) Slide Doors that slide apart from the center with (2) Sidelite Panels. ►►Installed within: ►►Mechanical Configurations: • Single Slide: (1) Slide Door that slides to the right or left with (1) Sidelite Panel. ►►Extrusion Configurations: • Pocketed Jamb Tubes • Slick Jamb Tubes ►►Emergency Egress: • Full Open: Both the Slide door and Swing Sidelite break out for emergency egress. • Fixed Sidelite: Fixed Sidelite is secured to the Header and Jamb Tube. Only the Slide door breaks out for emergency egress. Section 2a: Parts of the Header ⑥ ③ INDICATORS 61 6B H 62 BA GYRO TECH CAUTION Adjustments to the door can only be made with the NABCO Handy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. FUNCTION [SLIDING DOOR] 12VDC+ 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Senso r Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) N/O N/C Common SYMBOL No. 9DC12V 1 2 7 3 61 6B 4 5 H 6 M0 7 M1 62 8 SQ 9 10 BA SLS 11 OUT.A 12 OUT.B 13 OUT.C 14 OUT 15 16 7 GYRO TECH DS-150NA (24-11327) MADE IN JAPAN 1 12 11 7 0 98 To maintain warranty,repairs must be made by authorized NABCO facilities. ⑧ HANDY TERMINAL・6P Microprocessor Controller 248901- 10 O 5 A M P I POWER・2P 20VAC 50/60Hz ERROR No. 432 POWER TB2 S1 Mode SW Usage MODE M0 M1 Open Open TWO WAY Open Gnd ONE WAY Gnd Gnd HOLD OPEN Open Gnd NIGHT RELATED DEVICES・16P To protect against risk of fire or electric shock,use only the certified NABCO power supply. MOTOR・12P TRANSFORMER LABEL ZNR1 TB1 WARNING T1 ⑦ 765 NOISE FILTER ZNR2 ⑤ ④ >POM < ② ① ⑩ DN 0369 1. Power Cut Off Switch N/A 6. Belt Clip Assembly 4. U30 Microprocessor Control 24-8901-30 9. Anti Rise Roller 2. 3. 5. DS 150/U30 Power Supply Handy Terminal Harness DS 150 Operator Section 2b: Specifications 2-6 ⑨ 14-11741 12-13881 24-11327 7. 8. Figure 4-1 Contents of Header Timing Belt 3/4” wide Idler Assembly 10. Hanger Roller 11-12805 14-0795 22-9210 11-9037 11-10733 Note: Electrical conduit and switch or sensor wires should be pulled through the frame before mounting the GT1175 System. Note: To prevent electrical interference for the 120 Vac Line, always route 120 Vac Power in from the end of the header that is opposite to the controller and motor/operator. Refer to “Model GT 1175 Electrical Installation Manual”; P/N 15-10596-30 for more information Getting Started www.NabcoEntrances.com 1175 Standard Slide Door Installation Manual Rev. 10-27-15 Part #15-9244-30 Table 2-1 Electrical Specifications Electricity Power Input Available current for accessories Available wire size for incoming power Description 120 (±10%) AC 50-60Hz, 5 Amps U Series Control 0.35 Amps 12 Volts DC 14 AWG Section 2c: U30 Microprocessor Control The U30 Microprocessor Control has been designed to control numerous operating characteristics of the slide door system including speed, recycling sensitivity and reduced door opening width. It is programmed after installation is complete. Please refer to the “U30 Microprocessor Control Setup and Programming Manual”, P/N 15-9000-30 for detailed information. Section 2d: Associated Manuals Part Numbers ►►“GT 1175 Standard Slide Doors Quick Setup Parts Guide” (P/N C-00105) ►►“GT 1175 Electrical Installation Manual **with U30 Microprocessor Controller” (P/N 15-10596-30) ►►“U30 Microprocessor Control Setup and Programming Manual” (P/N 15-9000-30) ►►“Automatic Sliding Door Owners Manual” (P/N 14-8907) for Decal Installation ►►“NABCO Price Book” for Sensors, Switches, and Accessories Section 2e: Header Layout ►►Model GT 1175 Electrical Installation Manual ** with U30 Microprocessor Controller** P/N 15-10596-30 Section 2f: Wiring ►►GT 1175 Electrical Installation Manual** with U30 Microprocessor Controller** P/N 15-10596-30 Section 2g: Holding Beams ►►GT 1175 Electrical Installation Manual ** with U30 Microprocessor Controller** P/N 15-10596-30 Section 2h: Electric Lock (Optional) ►►GT 1175 Electrical Installation Manual ** with U30 Microprocessor Controller** P/N 15-10596-30 Section 2i: Troubleshooting ►►GT 1175 Electrical Installation Manual **with U30 Microprocessor Controller** P/N 15-10596-30 ►►U30 Microprocessor Control Setup and Programming Manual P/N 15-9000-30 Getting Started 2-7 1175 Standard Slide Door Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 CHAPTER 3: ASSEMBLE FRAME Section 3a: Prepare to Assemble Door Frame 1. Ensure the Rough Opening is correct size. XX The width of the Rough Opening should equal: PACKAGE WIDTH + 1/4 INCH ON EACH SIDE XX The height of the Rough Opening should equal: PACKAGE HEIGHT + 1/4 INCH R.O. WIDTH 1/4” 90.0° 90.0° R.O. HEIGHT DN 0081 Note: FINISHED FLOOR 1/4” 1/4” Figure 3-1 Masonry Opening Make allowances for tile or other existing materials that may change the floor height. 2. Ensure the floor is level across the entire opening. 1-3/4” Recess Threshold Finished Floor Jamb Tube 4-1/2” Track 1/2” DN 1110 Figure 3-2 Recessed Track 3. Place the Header on a flat surface. Remove (2) 8-32x0.625L Flat head screws used to secure the removable Cover. Remove the Cover by lifting it up and then pulling it out. Cover in Closed Posion DN 0393 3-8 8-32 x 5/8” Phillips Head Screw Swing UP to Open Li UP to Pull out Figure 3-3 Remove Header Cover Assemble Frame www.NabcoEntrances.com 1175 Standard Slide Door Installation Manual Rev. 10-27-15 Part #15-9244-30 4. Unplug the Sensor (if equipped). 5. Remove Parts boxes and/or Parts bags from inside Header. Section 3b: Assemble Door Frame (No Transom) FOR DOOR FRAMES WITH A TRANSOM SKIP TO SECTION 3C SINGLE BIPART DN 0768 1. Position Jamb Tubes on either side of Header according to the instruction sticker located on each Jamb Tube, showing proper location and orientation. Ensure the removable cover side of Header is facing up. 2. Orientate the Frame in relation to the building: XX Fixed Sidelite: Removable Cover side of Header must face the Exterior side of building. XX Full Open: Removable Cover side of Header must face the Interior side of building. NOTE: Header diagrams shown with Access Cover removed. FIXED SIDELITE UNITS: Door ACCESS COVER TYPICALLY Opening FACES THE EXTERIOR Door Opening FULL OPEN UNITS: ACCESS COVER TYPICALLY FACES THE INTERIOR DN 0394 Figure 3-4 Orientate the Door Frame in relation to the Building 3.b.a Secure Header to Slick Jamb Tubes 1. Secure the Header to each Jamb Tube with (6) 1/4-20 x .75 Whizlock screws. a. If installed correctly there will be a 1/8 inch gap between the bottom of Header and the flat surface. Header 1/8” gap Flat Surface DN 1349 Assemble Frame Slick Jamb Tube 1/4-20 x .75” Whizlock Screw Figure 3-5 Secure Header to Jamb Tubes 3-9 1175 Standard Slide Door Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 Section 3c: Assemble Door Frame (with Transom) FOR UNITS NOT INSTALLING A TRANSOM SKIP TO NEXT CHAPTER The Transom is installed on top of the Header when glass windows (or panels) are needed above the Door Unit. The Transom is used to frame glass windows or panels, with four parts: XX Transom Horizontal: • Secured between the top of (2) Pocketed Jamb Tubes, and the top of Rough Opening. • • Secured between the Transom Horizontal and the top of Header. Used to divide where windows or panels are inserted into. XX Transom Vertical: XX Transom Clip: • Installed on the Header to secure Transom Verticals. XX The Glass Stop Assembly: • A retaining strip mounted vertically or horizontally to hold glass windows or panels in place. Transom Horizontal Glass or Panel Transom Vercal Slide Door Header Jamb Tube Fixed or Breakout Panel DN 0688 Figure 3-6 Parts of Slide Door 1. Position Jamb Tubes on either side of Header according to the instruction sticker located on each Jamb Tube, showing proper location and orientation. a. Ensure the removable cover side of Header is facing up. 2. Orientate the Frame in relation to the building: XX Fixed Sidelite: Removable Cover side of Header must face the Exterior side of building. XX Full Open: Removable Cover side of Header must face the Interior side of building. NOTE: Header diagrams shown with Access Cover removed. FIXED SIDELITE UNITS: ACCESS COVER TYPICALLY FACES THE EXTERIOR Door Opening Door Opening FULL OPEN UNITS: ACCESS COVER TYPICALLY FACES THE INTERIOR DN 0661 3-10 Figure 3-7 Orientate the Door Frame in relation to the Building Assemble Frame www.NabcoEntrances.com 1175 Standard Slide Door Installation Manual Rev. 10-27-15 Part #15-9244-30 3.c.a Secure Transom Clips to Header 1. Locate pre-drilled holes on Header. 2. Secure Transom clips to Header with 10 x 1-3/4 inch Phillips Pan Head screws. a. Please refer to the instruction sticker located on the Header for proper location and orientation. b. Be sure to orientate all Transom Clips in relation to the Header cover. Orientaon Scker Vercal Transom Clip 10x1-3/4” Pan Head Screw Header Cover Top of Header HEADER COVER SIDE DN 0419 Figure 3-8 Secure Transom Clips to Header 3.c.b Secure Header and Transom to Pocketed Jamb Tubes Note: 1175 Slide Door Units installed with a Transom are shipped with Pocket Jamb Tubes only. 1. Place the Header between the Pocket Jamb Tubes so the removable cover side is facing up. a. Ensure the Frame is still orientated in relation to the building. 2. Secure the Header to each Jamb Tube with (6) 1/4-20 x .75 Whizlock screws. If installed correctly there will be a 1/8 inch gap between the bottom of Header and the flat surface. 1/8” gap DN 0949 1/4-20 x .75” Whizlock Screw Pocketed Jamb Tube Flat Surface Figure 3-9 Secure Header to Jamb Tubes 3. Slide and secure each Transom Vertical onto (1) Transom clip with 1/4-20 x 1” Flat Head screws. 4. Insert #8 x 1 inch Pan Head screws into each predrilled hole located on top of the Transom Horizontal. 5. Place the Transom Horizontal onto the Transom Verticals. Tighten each #8 x 1 inch Pan Head screw. Assemble Frame 3-11 1175 Standard Slide Door Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 #8 x 1” Pan Head Screw Transom Vercal 1/4-20 x 1” Flat Head Screws Transom Horizontal Transom Vercal Header Cover Transom Clip Header Cover DN 1151 Figure 3-10 Secure Transom Vertical to Transom Clip 6. Insert #8 x 1 inch Pan Head screws into each predrilled hole located on the outside face of each Pocketed Jamb Tube. 7. Align the Transom Horizontal with the Jamb Tubes. Tighten each #8 x 1 inch Pan Head screw. Jamb Tube #8 x 1” Pan Head Screw Transom Horizontal DN 0382 3.c.c Install the Tie Rods Figure 3-11 Attach Horizontal Transom to Jamb Tubes FOR TRANSOMS UNDER 11 FEET SKIP TO NEXT CHAPTER Note: Tie Rods are used for Transom Units that are 11 feet to 12 feet tall. Note: For units taller than 12 feet, please call Technical Support at 1-866-622-8325, for installation instructions. 1. Lift to position the assembled Frame into the rough opening. 2. Shim and Plumb Jamb Tubes in both planes to ensure the rough opening allows a 1/4 inch clearance. 3. Shim and plumb the Transom Horizontal at the top to ensure the rough opening allows a 1/4 inch clearance. Jamb Tube DN 1348 1/4” Shim and plumb for proper clearance 1/4” Horizontal Transom Figure 3-12 Shim and Plumb Frame 4. Go to the side of Header that is closest to the Exterior side of Door Opening, 3-12 Assemble Frame www.NabcoEntrances.com 1175 Standard Slide Door Installation Manual Rev. 10-27-15 Part #15-9244-30 5. Mark the exact location of each Transom Vertical by drawing a horizontal line (the full width of the Transom Vertical); along the outside edge of the Transom Horizontal; onto the ceiling of the Rough Opening. a. Do not draw the line wider than the Transom Vertical. b. It is recommended to use a level for this step. 6. From the center of each Horizontal line, measure 1 inch deep (towards the interior side of building). Mark a Vertical line onto the ceiling of the Rough Opening. a. It is recommended to use a level for this step. Mark Line Exterior side of Door Opening 3/8-16 Concrete Anchor hole end of 1” mark Measure 1” deep from center of Horizontal Line Ceiling 1” DN 0411 Figure 3-13 Mark Transom Vertical Locations 7. Carefully remove the Door Frame from the Rough Opening. Set aside. 8. At the end of each Vertical Line mark, drill (1) 3/8-16 Concrete Anchor hole into the ceiling of the Rough Opening, 9. Obtain all Tie Rods. (1) Tie Rod Parts box is shipped for each Transom Vertical. 10. Snap the Back Plate out from each Transom Vertical for easy access to the Tie Rod. 11. Transom Verticals are pocketed with (2) channels. Determine which channel is closest to the Exterior side of Door Opening. Channel closet to Exterior side of Door Opening DN 1350 Figure 3-14 Determine which Channel is closest to the Exterior Side of Door Opening 12. Insert (1) Tie Rod into that channel. 13. Insert each Tie Rod down into the 1 inch, pre-drilled hole located at the top of Header. 14. Once the Tie Rod is through the Header, loosely attach (1) Backing Plate, (1) 3/8 inch Washer, (1) 3/8 inch Lock Washer and (1) 3/8-16 Hex Nut (in that order) to the bottom of the Tie Rod. a. The length of each Tie Rod equals the distance between the top of the Header and the top of the Transom Horizontal, plus 2-5/8 inches. Assemble Frame 3-13 1175 Standard Slide Door Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 Concrete Anchor Securely fasten Tie Rod to Anchor with 3/4” minimum thread engagement into building structure 3/4” Min Horizontal Transom Tube Transom Vercal Tie Rod Transom Vercal Channel Leg of Roller Track Back Plate Top of Header Header Cover Backing Plate, 3/8” Flat Washer, 3/8” Lock Washer, and 3/8-16 Hex Nuts Figure 3-15 Insert the Tie Rod DN 1152 15. Allow each Tie Rod to rest on the Roller Track “Leg” within the Header. a. The Tie Rod must remain inside the Transom Vertical until the Frame is fully secured into the Rough Opening.Tie Rod Installation is completed after the Frame is installed. Transom Horizontal Tie Rod Vercal Transom (Mullion) Top of Header DN 0404 Boom of Header Figure 3-16 Rest Tie Rods on Roller Track 3-14 Assemble Frame www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-27-15 Part #15-9244-30 CHAPTER 4: SECURE FRAME TO BUILDING Section 4a: Secure door Frame to Building 1. Lift to position the assembled Frame into the rough opening. 2. Shim and Plumb Jamb Tubes in both planes to ensure the rough opening allows a 1/4 inch clearance. Shim and plumb the Header or the Transom Horizontal at the top to ensure the rough opening allows a 1/4 inch clearance. 1/4” Shim and plumb for proper clearance Horizontal Transom 1/4” Shim and plumb for proper clearance Jamb Tube 1/4” Header DN 0760 Figure 4-1 Shim and Plumb Frame 4.a.a Anchor Placements XX Anchors are not provided by NABCO. XX Anchors must be appropriate for the type of structure being fastened to. XX Screw in anchors to secure the Frame (per manufacturer’s specifications). XX Ensure anchor heads do not come in contact with edges of glass to prevent breakage. Note: It is recommended to countersink holes as required to flush the surface. Note: It is recommended to drill tap threads for 1/4 inch anchors in a steel or aluminum structure. Note: Do not overtighten anchors to prevent deforming Jamb Tubes. 36” 48” (914mm) (122mm) max max Y 36” 48” max max (914mm) (122mm) Y Y Y Y Y Y Y Y Y 48” max max XX Jamb Tubes • Y Y SLIDE DOOR DN 0767 48” (122mm) (122mm) SLIDE DOOR w/TRANSOM Figure 4-2 Anchor Placement Use 1/4 inch diameter anchors with a minimum of 3 per Jamb Tube, maximum is 48 inches on center. Drill 1/4 inch diameter holes in the face of Jamb and then countersink each hole. Secure Frame to Building 4-15 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 POCKETED JAMB / VERTICAL TRANSOM 1/4” Anchor 1/4” Anchor Hole(s) DN 0418 XX Transom Horizontal • • SLICK JAMB 1/4” Anchor 1/4” Anchor Hole(s) Figure 4-3 Screw Anchors Use 1/4 inch diameter anchors with a minimum of 3 per Transom tube, maximum is 48 inches on center. Anchoring is required within 8 inches of all vertical mullions. Drill 1/4 inch diameter holes in the face of Transom Horizontal and then countersink each hole. XX Header • To prevent Header sag, use 1/4 inch diameter anchors or 3/8 inch threaded rods, with a maximum 48 inches on center. First anchor maximum is 36 inches from each end of the Header. Drill 1/4 inch diameter holes inside the top of Header. Section 4b: Complete the Tie Rod Installation (For Transom Units only) 1. After the Frame has been installed, slide each Tie Rod up the Channel into each 3/8-16 Anchor located in the ceiling. a. The 3/8-16 Anchor is used to securely fasten the Frame. 2. Go to the bottom of each Tie Rod. Tighten the 3/8-16 Hex Nut and 3/8 inch Lock Washer to secure the Backing Plate. 3. Snap the Back Plate back into each Transom Vertical. a. It may be necessary to use a rubber mallet to slightly tap the Back Plate into place. b. Protect the surface of the Back Plate before hitting it with a rubber mallet. 4-16 Secure Frame to Building www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-27-15 Part #15-9244-30 CHAPTER 5: 120 VAC GENERAL WIRING WARNING Shut the installation site, branch Circuit Breaker OFF. Failure to do so may result in serious personal or fatal injury. When uncertain whether power supply is disconnected, always verify using a voltmeter WARNING All high voltage electrical connections must be made by licensed electricians according to National and Local electrical codes/regulations. CAUTION Permanent wiring shall be employed as required by local codes. CAUTION Keep all Incoming 120 VAC wiring separate from low voltage wiring within Header. 120 VAC Power wires must be routed (separate from other wiring) located near the top of inside Header. CAUTION Ensure that the Grounding of the Electric Power Supply is installed/connected in a proper way (especially the PE Cable from the Building Side). Attention: Insert all Incoming 120 VAC Power wires into the pre drilled Electric Service Access Hole located at the left or right side of Header End Cap. BC DS-1500 D24-113270 Nabtesco Corporation N 32 4 1211 0 8 7 6 5 Auxiliary 120 VAC Power wires 1 7 10 9 L 120 VAC General Wiring T1 (These wires normally coiled and ed up) H M0 Open Gnd Gnd Open Mode SW Usage MODE M1 Open TWO WAY Open ONE WAY Gnd HOLD OPEN Gnd NIGHT ! CAUTION 62 ERROR PE AC 115V ± 10% 50 / 60 Hz GYRO TECH 6B BA MADEI N JAPAN To protect against risk of fire or electric shock,use only the certified NABCO power supply. ! NABC O 61 GYR O TECH TB2 TB1 NOISE FILTER MOTOR・12P POWER INDICATORS PRESS TO RESET O NA NAB CO LOAD RED INDICATES POWER IS OFF ! WARNING NABCO POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 -CIRCUIT-BREAKER- POWER・2P 20VAC 50/60Hz S1 Motor/Operator P/N M-00395 U30 Microprocessor Control P/N V-00020 ! Adjustments to the door can only be made with the NABCO Handy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. ! To maintain warranty,repairs must be made by authorized NABCO facilities. HANDY TERMINAL・6P No. Microprocessor Controller 248901FUNCTION [SLIDING DOOR] 12VDC+ 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RELATED DEVICES・16P On/Off Power Switch Power Supply P/N V-00029 < Ground Wire It is recommended for the Installer to house all Incoming 120 VAC wires within an Electrical Conduit. >PO M Note: 120 VAC DN 0647 5-17 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 CHAPTER 6: WIRE THE SWITCH ASSEMBLY Note: Do not secure the Switch Assembly to the Jamb Tube until after the Slide door installation is complete. Note: The U30 Microprocessor Control, Main Harness comes in three lengths: 36 inches, 72 inches, and 80 inches. The length used is dependant upon the type of installation. Note: The Rocker Switch and the Key Switch are both installed the same way. 1. Go inside the Header. Locate the Pin wiring that is attached to the Main Harness. 2. Draw the Pin wiring through a hole located at the side of Header and Jamb Tube. Continue to route down the Jamb Tube. 3. Pull the Pin Wiring through the cut out. 4. Obtain (1) loose 5 Circuit Pin Housing from the Parts Box. 5. Insert each Pin into the 5 Circuit Pin Housing accordingly: a. 1 = Red, 2 = Orange, 3 = Blue, 4 = Green, 5 = Orange 6. Connect the Switch Harness from the back of the Switch Assembly to the Main Harness. a. Place extra wiring back inside the Jamb Tube. 7. Insert the Switch Assembly into the Cut Out. 8. Secure the Switch Assembly to the Jamb Tube with (2) 10-32 x 1/2 inch Phillips Head Screws. Header Plate Wire Access Hole Jamb Tube Wire Access Hole Female Pin Wiring Key Switch Male Pin Housing DN 1002 6-18 Rocker Switch Red Orange/White Blue Green Orange 1 2 3 4 5 Female Pin Housing Figure 6-1 Secure the Switch Assembly to the Jamb Tube Wire the Switch Assembly www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-27-15 Part #15-9244-30 CHAPTER 7: LAY DOWN THE THRESHOLD (Optional) FOR UNITS NOT INSTALLING A THRESHOLD SKIP TO CHAPTER 8 Note: Do Not permanently secure the Surface Threshold until the Slide Door has been installed. Doing so may cause misalignment. Note: Thresholds are factory cut to be the same width as the door opening. However, extending the Threshold across the entire door opening is optional. To order additional track, please contact customer service at (877) 622-2694. Standard Thresholds vary in width and can be installed two different ways: XX Recessed: Installed into the floor (1/2 inch deep) across the full length of the track. XX Surface: Installed on the surface of the floor with ramps attached to both sides. RECESSED TRACK 4 ” Bumpers DN 0087 SURFACE TRACK 7” Bumpers Figure 7-1 Recessed vs Surface Track Attention: The Threshold must be laid down so the Channels are located on the side of Slide Door. BUMPERS (Used to Cushion Boom Guide Prongs) Jamb Tube FILLER INSERTS Sidelite (Used to Fill In areas Boom Guide does not slide within) Threshold (Channels installed on side of Slide Door) Bumpers DN 1369 Jamb Tube Filler Inserts 7.1 Install the Surface Threshold Figure 7-2 Lay down Threshold Correctly 1. Obtain the Surface Threshold. 2. Snap a chalk line on the floor from Jamb to Jamb. XX Full Open: On the Exterior side XX Fixed Sidelite: On the Interior side Lay Down the Threshold 7-19 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 FULL OPEN Jamb Tube EXTERIOR Chalk Line DN 1027 FIXED SIDELITE Jamb Tube 3. Position the Threshold until the full length is flush with the chalk line. Chalk Line Figure 7-3 Snap Chalk Line 4. Hang a Plumb Bob from the Header. 5. Ensure the outside edge of the Threshold is 1/8 inch from the Plumb line. Header Header 6-1/2” Plumb Line + 1/8”to edge of track. Jamb Tube 6-1/2” (not Pocketed) 6-3/8” 4-1/2” 1/8” Pocketed Jamb Tube 4-1/2” Track 6-3/8” Track 1/8” DN 0090 6. Locate (2) screw splines on each end (exposed side) of the Threshold. Figure 7-4 Plumb Line 7. Secure (1) Threshold End Cap to each screw spline with (2) 6 x 3/8 inch Phillips Head screws. a. Use a 1/8 inch diameter drill bit to make the screw spline bigger if the Threshold End Cap can not be properly secured with the screws provided. Standard Floor Track 6 x 3/8” Phillips Head Screw Screw Spline Standard Threshold End Cap Figure 7-5 Secure Threshold Cap to Threshold DN 0091 8. Permanently secure the Surface Threshold after Slide Doors are completely installed. 7.2 Recessed Threshold 1. Snap a chalk line on the floor from Jamb to Jamb on both sides. 2. Create a channel that is 1/2 inch deep, full width of Jamb Tubes, and full length of Threshold. 3. Place the Threshold inside the channel so the full length is flush with the chalk line. Floor Surface Track 1/2” DN 0761 7-20 Figure 7-6 Track Recess Lay Down the Threshold www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-29-15 Part #15-9244-30 CHAPTER 8: INSTALL THE SIDELITE There are (2) Sidelite Configurations: XX Full Open: The Swing Sidelite has breakout capabilities. Both the Swing Sidelite and Slide door must breakout at the same time. XX Fixed Sidelite: The Fixed Sidelite does not have breakout capabilities. Only the Slide door can breakout. FULL OPEN FIXED SIDELITE Fixed Sidelite or Wall Track Swing Sidelite Slide Door DN 0762 Figure 8-1 Sidelite Configurations Section 8a: Full Open Sidelite FOR FIXED SIDELITE UNITS SKIP TO SUBSECTION 8.B 8.a.a Install the Bottom Pivot 1. Go to the bottom of the Pivot Jamb Tube. Insert the Bottom Pivot into the hole. 2. Secure the Bottom Pivot to the Pivot Jamb Tube with (1) 1/4-20 x 1/2 inch Phillips Head screw. 3. Go to the screw hole located in front of the Barrel. 4. Secure the Floor Pivot to the Threshold with (1) 1/4-20 x 1/2 inch Phillips Head Screw. 5. Insert (1) 1/4 x 2-3/4 inch Phillips Head Screw inside the Barrel. Tighten. 6. Cap the Barrel with (1) Bushing. Boom Pivot 1/4-20 x 1/2” Phillips Head Screw DN 1045 8.a.b Partially Install the Limit Arm 1/4-20 x 1/2” Phillips Head Screw 1/4 x 2-3/4” Tapcon Screw Bushing Figure 8-2 Temporarily Secure Bottom Bracket to Jamb Tube 1. Slide (1) .255 ID x .900 OD x .125 THK Nylon Washer onto (1) 1/4-20 x 1 inch Phillips Head Screw. 2. Go underneath the Limit Arm. Insert the Washer and Screw up into the screw hole. 3. Go to the pre-drilled screw hole located at the bottom of Header (on the Pivot Side of Sidelite). Install the Sidelite 8-21 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-29-15 4. Secure the Limit Arm to the Header by tightening the Screw. a. Loosely tighten (just enough to keep the Screw assembly from falling out of the hole). b. Limit Arm installation is completed after the Swing Sidelite is fully installed. Limit Arm Limit Arm Wheel .255 x .900 x .125 THK Nylon Washer 1/4-20 x 1” Phillips Head Screw DN 0771 Boom of Header Pivot Hole Figure 8-3 Partially Install the Limit Arm 8.a.c Install the Full Open Sidelite onto the Upper Pivot and Bottom Pivot 1. Locate the Bottom Pivot inside the Pivot Stile (at the bottom). Insert the Bottom Pivot into the Floor Pivot Barrel. Jamb Tube Barrel DN 1046 Boom Pivot Figure 8-4 Position the Swing Sidelite Panel over the Bottom Pivot at 90° angle 2. Go to the Top Pivot that is preinstalled inside the Pivot Stile. Push the Top Pivot down by pressing on the Spring Pin. 3. Align the Top Pivot with the Pivot Hole located at the bottom of Header. 4. Release the Spring Pin to allow the Top Pivot to snap up into the hole. Ensure the Top Pivot fully engages the hole. a. If necessary, use a flathead screwdriver to lift up on the Spring pin until the Pivot Pin is fully seated within the hole. b. Ensure not to pinch Cable Wiring. Cable Wiring from Main Harness (Inside Header) Top Pivot Pivot Sle Hole Spring Pin 8-22 Break Out Direcon Spring Pin DN 0705 Figure 8-5 Insert Top Pivot into Header Install the Sidelite www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-29-15 Part #15-9244-30 8.a.d Complete Installation of the Limit Arm 1. Swing open the Swing Sidelite 90 degrees. Align and then rest the Limit Arm inside the Top Rail. 2. Open the Swing Sidelite all the way. Tighten (1) 1/4-20 x 1 inch Phillips Head screw to secure the Limit Arm to the Header. 8.a.e Adjust the Ball Detents Note: Breakout resistance for Ball Detents must meet ANSI Standard A156.10 or Local Codes. 1. Go to the top of the Strike Stile. With a 15/16” Open End wrench, loosen the Nut to raise or lower the Ball Detent so it has light contact with the Bottom of Header. 2. Open and close the Swing Door several times to score the surface on the Bottom of Header locate and mark where the Score intersects the center groove. 3. With a 1/4 inch drill bit, drill a screw hole through the Bottom of Header. Countersink the screw hole 3/8 inch x 82°. Ball Dentent Drilled and Countersunk Hole Nut Score Mark Top of Strike Sle DN 0764 90° Figure 8-6 Adjust the Ball Dentent on top of Strike Stile 4. Go to the bottom of the Strike Stile. With a 15/16” Open End wrench, loosen the Nut to raise or lower the Ball Detent so it has light contact with the Threshold. 5. Open and close the Swing Door several times to score the surface on the Threshold. Locate and mark where the Score intersects the center groove. 6. With a 1/4 inch diameter drill bit, drill a hole through the Threshold (Just deep enough for the Ball Dentent to fit within). Countersink the screw hole to be 1/4 inch x 82°. 90° Drilled and Countersunk Hole Boom Rail Nut Ball Dentent Score Mark Figure 8-7 Adjust the Ball Dentent on bottom of Strike Stile DN 0765 7. Close and then break open the Swing door to test fit for both Ball Detents. a. To adjust the fit, increase the size of the hole and countersink. b. Do Not over-drill the hole. If hole is overdrilled the Threshold will need to be replaced. c. For additional travel remove the Ball Detent Bracket to lower or raise the Ball Detent. Install the Sidelite 8-23 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-29-15 8.b Fixed Sidelite 8.b.a Secure the Fixed Sidelite to the Door Frame 1. Locate (1) cut out at the top of Strike Stile. Align and then slide the Fixed Sidelite until (1) mounting bracket (preinstalled under the Bottom Lip of Header) can be seated inside the Cut Out. Cut Out Strike Sle Mounng Bracket DN 0862 Figure 8-8 Slide Mounting Bracket into Cut Out 2. Locate (2) Cut Outs on the side of the Pivot Stile. Align and then slide the Fixed Sidelite until (2) Mounting Brackets (preinstalled on the Pivot Jamb Tube) can be seated inside each Cut Out. 3. Slide the Fixed Sidelite towards the Interior of the Building until both Mounting Brackets butt up against the inside wall of the Pivot Stile. 1/4-20 x 1/2” FlatHead Screw Header Mounng Bracket (Inside Vercal Mullion) Cutout Clearance 1/4-20 x 1/2” Flat Head Screw Jamb Tube Mounng Bracket Jamb Tube Mounng Bracket DN 0863 Figure 8-9 Slide Mounting Block into Top Rail 4. Snap a chalk line between Jamb Tubes in front of Sidelite Panel. If the Sidelite Panel runs parallel to chalk line, it is square. 5. Secure the Fixed Sidelite Panel to all (3) Mounting Brackets with 1/4-20 x 1/2 inch Flat Head Screws. Jamb Tube DN 0624 Chalk Line Jamb Tube Fixed Panel Figure 8-10 Ensure Fixed Panel is Square 8.b.b Insert the Bottom Guide Double Roller Assembly under the Strike Stile 1. Go to the bottom of Strike Stile. Remove the Bottom Guide Cover Plate. Set aside. 8-24 Install the Sidelite www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-29-15 Part #15-9244-30 Boom Guide Cover Plate 1/4-20 x 3/4” Phillips Screw DN 0128 Figure 8-11 Remove Bottom Guide Cover 2. Install the Bottom Guide Double Roller Assembly by sliding (2) rollers into the Bottom Rail so the Bracket sticks out from underneath (in direction of where the Slide door is to be installed). 3. Use the Bracket to slide the Bottom Guide Double Roller Assembly towards the Pivot Stile. Boom Guide Assembly Boom Rail Floor DN 0865 8.b.c Install the Floor Bracket Figure 8-12 Slide Bottom Guide Assembly into Bottom Rail 1. Go to the bottom of the Strike Stile. Insert the Floor Bracket inside the Bottom Rail so the bottom plate portion sticks out from underneath (in direction of where the Slide door is to be installed). 2. Close the Slide Door. Adjust the Fixed Panel for weathering gap. Adjust the Slide Door for rocking. 3. Secure the upper plate portion of the Floor Bracket to the side of Strike Stile with (1) 1/4-20 x 1/2 inch Phillips Head screw. 4. Use the Floor Bracket as a template to drill (2) screw holes for #14 x 1-1/4 inch Flathead Tapcon screws. 5. Secure the Floor Bracket to the floor with (2) #14 x 1-1/4 inch Flathead Tapcon screws. Replace the Cover Plate. Boom Rail 1/4 x 1-1/4” Tapcon Screw Strike Sle 1/4-20x1/2” Phillips Head Screw DN 0864 Floor Bracket Install the Sidelite Figure 8-13 Install Bottom Bracket 8-25 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 CHAPTER 9: INSTALL THE SLIDE DOOR 9.a Secure the Slide Door Carrier to Belt Clips CAUTION Do not test Breakout until all adjustments are made and doors are secured. 1. Cover the Sidelite Panel with cardboard on the side that will face the Slide door. An-Rise Roller Carrier Hanger Roller Nut DN 1043 CAUTION Figure 10-1 Carrier with Rollers Do not rotate the Roller Axle counter-clockwise. Doing so will unthread the Axle from the Roller Assembly. 2. Go to the Carrier on top of Slide Door. Loosen (1) 7/16-20 Whiz Lock Nut on each Roller by inserting (1) 7/32” Allen wrench into the exposed end of a Roller Axle. Hold the 7/32 inch Allen wrench in place to keep the Roller Axle stationary. At the same time, loosen (1) 7/16-20 Whiz Lock nut with a 15/16 inch Open End Wrench. An-Rise Roller Hanger Roller Nut End of Roller Axle DN 1028 Figure 10-2 Loosen Nuts 3. Lift and then slightly tilt the Slide door to place all (4) Rollers onto the track (located inside the Header). Track Roller Carrier DN 0779 9-26 Figure 10-3 Install Carrier onto Track Install the Slide Door www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-27-15 Part #15-9244-30 4. Secure the Belt Clip to the Carrier with (2) 1/4-20 x 3/4 inch Whiz-Lock screws. a. Long Belt Clips are installed on Single Slide Door Units or Lead Slide Doors for Simultanuous Pair Units. b. Short Belt Clips are installed on Trail Doors for Simultanuous Pair Units; to the left side of Carrier. LEAD DOORS AND TRAIL DOORS ARE ONLY INSTALLED ON SIMULTANUOUS PAIR UNITS Long Belt Clip used for Single Slide Door and Lead Door Carrier Short Belt Clip used for Trail Doors 1/4”-20 x 3/4” Whiz-Lock Screw DN 0720 Figure 10-4 Secure Belt Clips to Carrier 9.b Install Bottom Guides 9.b.a Insert Bottom Guide into the Threshold (Full Open Sidelite) FOR FIXED SIDELITE UNITS SKIP TO SUBSUBSECTION 9.B.B 1. Locate the Bottom Guide Assembly that was preinstalled inside the Slide Door Strike Stile. 2. Lift up the Prongs until the Bottom Guide is directly above the Guide Channels. Drop the Prongs into the Guide Channels. Li Up Boom Guide; Prongs Guide Channels DN 0894 Figure 10-5 Drop Prongs into Channel Guides 9.b.b Secure the Bottom Guide Double Roller Assembly to the Slide Door (Fixed Sidelite) FOR FULL OPEN UNITS SKIP TO SUBSECTION 9.C 1. Go to the Bottom Rail of Fixed Sidelite. 2. Locate the Bottom Guide Double Roller Assembly. a. The Bracket will be sticking out from underneath. Fixed Sidelite DN 0640 Install the Slide Door Slide Door Washer 1/4 - 20 x 3/4” Whiz-Lock Screw Figure 10-6 Install Sliding door to Bottom Guide Assembly 9-27 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 3. Slide the Slide Door’s Pivot Stile onto the Bracket. 4. Support the weight of the Fixed Sidelite. 5. Breakout the Slide door to Full Open position. 6. Secure the Bracket to the Pivot Stile with (2) 1/4 - 20 x 3/4 inch Whiz-Lock screws. 9.c Adjust the Rollers 9.c.a Hanger Rollers 1. Raise or lower the Slide door by turning the Axle clockwise with a 15/16” Open End Wrench. a. The appropriate gap between the Bottom Rail and floor is between 11/16 inch to 15/16 inch; with the nominal gap being 7/8 inch. Hanger Roller 55mm An-Rise Rollers Hanger Roller Hanger Roller Centers must be to the RIGHT of their bolts. DN 1044 Figure 10-7 Door Adjustment 2. Ensure the Leading Edge of the Slide door and (other Slide door or Jamb Tube) are parallel. 3. Ensure the Leading Edge of the Slide door and Header are parallel. 4. Tighten the 7/16-20 Whizlock nuts. Do not overtighten. Parallel Gap Parallel Gap Parallel Gap Parallel Gap Parallel Gap DN 0895 BIPART 11/16” (17mm) to 15/16” (24mm); 7/8” (22mm) nominal 9.c.b Anti Rise Rollers SINGLE Figure 10-8 Floor Gap 1. Loosen (2) Anti-Rise Rollers located towards the middle of the Carrier. 2. Slide the Anti-Rise Roller up or down within the slot until there is 1/64 inch to 1/32 inch gap between the Roller Wheel and the Top Track. Gap should be about the same thickness as a credit card. 9-28 3. Tighten the 7/16-20 Whizlock nuts. Do not overtighten. Install the Slide Door www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-27-15 Part #15-9244-30 An-Rise Track 1/64 inch to 1/32 inch clearance Insert 7/32” Allen Wrench Slide An-Rise Roller up in slot unl a 1/64 inch to 1/32 inch clearance is between the An-Riser Wheel and the An-Riser Track. 9.d Adjust the Interlocks DN 0633 Figure 10-9 Wheel and Track Clearance 1. Manually close the Slide Door. Ensure the Interlocks are properly engaged. If not, adjust the Interlocks. DN 1051 Interlock Correctly Engaged Interlock NOT Correctly Engaged Figure 10-10 Close Door to Adjust Interlocks 9.d.a Adjust the Interlock Note: Adjust Interlocks so there is no contact between the Rail and the Interlock. Any contact will cause the Slide Door to bind. 1. Obtain (1) parts bag containing (4) Shims that was taped to the Slide Door at the NABCO factory. 2. Remove the Interlock on the Sidelite, Strike Stile. 3. Place (1+) shims directly underneath the Interlock. Line up the screw holes. 4. Secure the Interlock assembly to the Sidelite Strike Stile with (2) #10-32 x 5/8 inch Phillips Head Screws. a. Loosely tighten the mounting screws just enough to keep the Interlock assembly from falling out of place. Sle Shim Interlock #10-32 x 5/8” Phillips Head Screw DN 0745 Figure 10-11 Place (1+) Shim under Interlock 5. Go to the Interlock located on the Pivot Stile of the Slide Door. Loosen the mounting screws. 6. Manually close the Slide Door. The loosened Interlocks will automatically adjust to proper position. 7. Lock the Interlock and 1+ Shim in place by tightening the #10-32 x 5/8 inch Phillips Head Screws. Install the Slide Door 9-29 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 Section 9e: Permanently install the Threshold 1. Go to each end of Threshold. Mark (1) drill hole approximately 4” from each edge. 2. Mark remaining drill holes to be evenly spaced. Drill Screw Holes in Metal Strip Figure 10-12 Mark and Drill Holes on Threshold DN 1047 3. With a 1/4 inch masonry drill bit, drill through the Threshold and into the floor no less than 1-1/2 inch deep. 4. Secure the Threshold with Fasteners not provided by NABCO. Section 9f: Threshold Maintenance 1. Check for wear of Bottom Guide Roller and Bumpers inserted within Threshold Channels. 2. Listen for squeaking/grinding noise. 3. Look for dirt/debris/excessive build-up. If dirt/debris/excessive build-up is found. 1. Vacuum to remove loose material. 2. Wipe off the Threshold. 3. Use (1) slotted Screw Driver to remove dirt/debris and/or excessive build–up located within Threshold Channels. 4. Inspect weekly and daily during winter as snow and ice can build up. Fastener not provide by NABCO Metal Strip Flat Surface DN 1048 9-30 Figure 10-13 Secure Threshold to Flat Surface Install the Slide Door www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-27-15 Part #15-9244-30 CHAPTER 10: INSTALL THE WEATHERING FIXED SIDELITE Roller Assembly FULL OPEN Boom Guide Slide Door Weathering 1/8” Swing Sidelite BREAKOUT SIDE Weathering Figure 10-1 Weathering Placement Slide Door Weathering DN 0119 1. Install Brush by sliding it into the Brush Holder: ►►Fixed Sidelite 1. Secure the Brush Holder against the Bottom Rail of Slide door with (3) #6 x 1/2 inch self tapping screws. ►►Full Open 1. Secure the Brush Holder against the Bottom Rail of Swing Sidelite with (3) #6 x 1/2 inch self tapping screws. a. It is recommended to leave at least a 1/8 inch gap between the Edge of the Pivot Stile and the Brush Holder, while allowing 1/8 inch Vinyl to extend past the Brush Holder so the gap is filled. 2. Breakout the Swing Sidelite. Secure the Brush Holder against the Bottom Rail of Slide door with (3) #6 x 1/2 inch self tapping screws. Section 10a: Apply Caulking Bead 1. Ensure the entire Door Frame is properly secured to the Rough Opening. 2. Apply caulking bead between the Door Frame and Rough Opening (inside and outside). 3. Apply caulking bead to the Threshold at the bottom of Door Frame. Caulk the top and both sides of Door Frame DN 0883 Install the Weathering Caulk the Threshold 10-31 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 CHAPTER 11: INSTALL THE GLASS STOPS Glazer must be fully trained and qualified. Failure to do so may result in bodily injury, or property damage. WARNING Note: Ensure the installation area is free of debris and/or sharp objects. Failure to do so may damage the glass or contaminate the glazing process. Section 11a: Door Panel Note: The Snap Base and Vinyl Seals/Gaskets are preinstalled at the NABCO Factory. 1. Ensure the Snap Base is free of debris and/or sharp objects. 2. Install the Setting Blocks (not provided by NABCO) and Glass Panel. 3. Snap the Glass Stop into the Snap Base. 1/4” (6mm) Glass Stop Seng Block Glass Panel Vinyl Bumper 1/4” (6mm) Snap Base DN 1031 Section 11b: Transom Figure 11-1 Door Panel Glass Stop Note: Vinyl Bumpers are preinstalled at the NABCO Factory. 1. At the top of Header, snap each Snap Base inside the Channel on either side of Vertical Transoms. XX Full Open Doors: • • Install the Snap Base on the Exterior Side of the Building. Removable Cover faces Interior Side of the Building. XX Fixed Sidelite Doors: • • Install the Snap Base on the Exterior Side of the Building. Removable Cover faces the Exterior Side of the Building. 2. Install the Setting Blocks (not provided by NABCO) and Glass Panel. 3. Snap (1) Glass Stop into each Snap Base. 11-32 Install the Glass Stops www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-27-15 Part #15-9244-30 1/4” (6mm) Snap Base 1/4” (6mm) Glass Stop FIXED SIDELITE SLIDE DOOR UNIT (Removable Cover on Exterior Side) 1/4” (6mm) Glass Stop Channel 1/4” (6mm) Snap Base Channel FULL OPEN SLIDE DOOR UNIT (Removable Cover on Interior Side) DN 1032 Section 11c: Dust Protector Hoods (Clean Room) Figure 11-2 Transom Glass Stops Note: All Aluminum Hoods and Vinyl Shields are installed for Clean Room Slide Door Units only and are not manufactured by NABCO. Please call Customer Service for replacement parts at 1-888-679-3319. 11.c.a Door Panel and Transom Note: Aluminum Hoods are installed at the bottom of each Door panel and Transom. 1. Install Glass Stops according to Subsection 14.1 and Subsection 14.2. 2. Place each Aluminum Hood over each Glass Stop so the bottom edge of the Aluminum Hood is resting on the surface. a. Do Not remove protective paper from double sided Cladding Tape at this time. 3. Insert the bottom half of each Vinyl Strip inside the gap that is located behind the Aluminum Hood. The Vinyl Flap must be laying on top the Aluminum Hood. 4. Hold the assembly in place while it is pressed up against the Glass Panel. Make a temporary Mark along the full length of the Vinyl Strip. a. Ensure the bottom edge of the Aluminum Hood is still resting on the surface for proper alignment. 5. Remove the assembly. 6. Remove the protective paper to expose the Cladding Tape from the Vinyl Shield. 7. Align the Vinyl Strip to the temporary Mark and adhere to the Glass Panel. 8. Remove the protective paper to expose the Cladding Tape from the Aluminum Hood. 1. Align the Aluminum Hood with the Vinyl Shield. 2. Adhere the Aluminum Hood to the Glass Stop and tuck it under the Vinyl Flap. Install the Glass Stops 11-33 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 Glass Panel Tuck Aluminum Hood under Vinyl Shield Adhere Vinyl Shield along Mark Line Mark Line Vinyl Shield Gap Adhere Aluminum Hood to Glass Stop Surface Aluminum Hood DN 1033 Inside Face Aluminum Hood Cladding Tape Vinyl Flap Cladding Tape Assembly Vinyl Shield Figure 11-3 Install Dust Protector Hoods for Door Panels and Transoms 11.c.b Header 1. Go to the side of Header that has the Removable Cover. 2. Position the Stainless Steel Hood on top of the Header so the (turned under) bottom lip is resting on the Header surface and the inside face is pressed up against the building. a. Ensure proper length and fit is correct. 3. Remove all protective paper to expose the Cladding tape. 4. Adhere the Stainless Steel Hood to the Header. 3/8” Dust Protector Hood Building 45 DN 1034 1/2” Header Figure 11-4 Install Dust Protector Hoods for Header 11-34 Install the Glass Stops www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-27-15 Part #15-9244-30 CHAPTER 12: ADJUSTMENTS Section 12a: Adjust Preload 1. Support the weight of Slide Door, then Breakout Slide door approximately 5 degrees (just enough to expose the Preload Adjustment Screw located on back edge of door). Do not let Slide door push up against any other Door Panel. 2. Check for door sag. The Slide door should latch without having to be manually lifted. Preload Adjustment Screw Pivot bar Carrier Door Sag Pivot Block Preload Adjust DN 0726 Figure 12-1 Check Door Sag 3. Go to the Preload Block located inside Top Rail. Loosen (2) Locking Bolts. 4. Go to the back edge of Pivot Stile. Reduce Door sag by tightening the 5/8 inch Set Screw with an 7/32 inch Allen Wrench. Do Not allow the Adjustment Set Screw to protrude more than 7/32 inch past the end of stile. a. If deemed necessary, substitute the 5/8 inch Set Screw with the optional 1/2 inch Set Screw supplied by NABCO. 5/16” Adjustment Set Screw Preload Block (If needed: use oponal 1/2” Set Screw provided by NABCO) DN 0727 12.a.a Correct Preload Misalignment Locking Bolts Limit Arm Figure 12-2 Adjust the Preload 1. Break Open the Slide Door. Locate the Carrier Pivot Assembly inside the Top Door Web. 2. Loosen the 5/16-24 x 1/2 Set Screw located on the Pivot Stile at the Top. 3. Loosen (2) 1/4-20 x 1.75 Hex Screws used to secure the Carrier Pivot Assembly to the Top Door Web. 4. Slide the Carrier Bar to the left or right, until the Slide Door is aligned to the Carrier. 5. Tighten all screws. Install the Weathering 12-35 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 1/4-20 x 1-3/4” Hex Screw Carrier and Door Misaligned aer adjusng preload Pivot Carrier Misaligned 5/16-24 x 1/2” Set Screw DN 0741 Figure 12-3 Correct Preload Misalignment 6. Verify that the Lower Panic Catch inside the Door Web is still aligned to the Upper Panic Catch inside the Carrier. If an adjustment is necessary: 1. Go to the Lower Panic Catch. Loosen (2) 1/4-20 X 1-1/4 inch Socket Screws used to to secure the Lower Panic Catch to the Door Web. 2. Slide the Lower Panic Catch to the right or to the left until it is aligned to the Upper Panic Catch. Tighten Socket Screws. 1/4”-20 x 1-3/4” Socket Screw Lower Panic Catch Assembly DN 1368 12.a.b Adjust the Ball Plunger Figure 12-4 Align the Lower Panic Catch to the Upper Panic Catch 1. Breakout the Slide door. Go inside the Top Rail (closest to the Strike Stile). Remove the Panic Catch Assembly. 1/4-20 x 1-1/4” Socket Screw Panic Catch Loosen the Set Screw 2. Loosen the Set screw that is located in front of the Panic Catch. Ball Plunger DN 0122 Figure 12-5 Panic Adjustment 3. Go underneath the Panic Catch. Raise or lower the Ball Plunger to adjust the engagement. a. The Ball Plunger must be adjusted for proper breakout resistance to meet ANSI A156.10 code and/or local code. b. Use minimal engagement if Panic Hardware is used. 4. Tighten the Set screw. Secure the Panic Catch Asssembly inside the Top Rail with (2) 1/4-20 x 1-1/4 inch Socket Head screws. 12-36 Install the Weathering www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-27-15 Part #15-9244-30 12.a.c Adjust the Breakout Magnet 1. The Magnet is secured to the Limit Arm Bracket that can slide to the Left and Right. Slide the Breakout Magnet to the Left or to the Right until it is aligned with the Magnetic Reed Switch. a. The Magnetic Reed Switch is a 3/8 inch diameter black circle located on the Bottom Lip of Header. Magnet Magnet Boom Lip of Header Magnec Reed Switch DN 0781 Breakout Slide Door Figure 12-6 Breakout Magnet Location 12.a.d Units 54 Inches Wide (or greater) and/or over 200 Pounds 1. Go to the Bottom Rail. Remove (1) End Cap. 2. Break Open the Slide door. Locate the Nose Caster that was pre-installed within the Strike Stile. 3/8 - 16 Nut Strike Edge of Rail DN 0636 Nose Caster Floor 1/16” (1.59mm) to 1/8” (3mm) gap from floor Figure 12-7 Adjust the Nose Caster 3. Loosen the #8-32 Set Screw. Position the Wheel so it is perpendicular to the Bottom Rail. Retighten the #8-32 Set Screw. 4. Fully close the Slide door. Ensure the Nose Caster does not hit or scrape the floor. Reinstall the End Cap. Install the Weathering 12-37 S1 5 A M P GROUND HARNESS P/N 14-11872 ON/OFF POWER SWITCH 1 NR T1 AUXILIARY 120 VAC POWER WIRES (THESE WIRES NORMALLY COILED AND TIED UP) 120 VAC TB2 NABCO WHITE BLACK BROWN BLUE POWER SUPPLY HARNESS P/N 14-11874 MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 GYRO TECH RED NABCO OUTPUT TIMER 0 = (DO NOT USE) 1 = (DO NOT USE) 2 = (DO NOT USE) 3 = ELECTRIC STRIKE FUNCTION OUTPUT: 0 = ELECTRIC STRIKE OUTPUT OUTPUT TIMER 1.0 SEC OPENING 3 SEC ON FULLY CLOSED OUTPUT SIGNAL OFF ACTIVATION SIGNAL OFF CLOSING FULL OPEN ON FULLY CLOSED U30 ELECTRIC STRIKE OUTPUT SIGNAL HANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER = 0, 1 or 2, ROCKER SWITCH SETTING: ONE WAY OR NIGHT MODE WIRING FOR ELECTRIC LOCK ONLY SHOWN P/N 24-11877 SYMBOL No. 9DC12V 1 1 7 2 2 3 61 3 6B 4 4 5 H 5 6 M0 6 7 M1 7 Exterior Activation 8 62 8 Sequential Activation SQ 9 9 Breakout Detector 10 BA 10 11 SLS Sidelite Presence Sensor 11 Contact Output (Class2 Load only) 12 N/O OUT.A 12 GRAY (OUT B) 30V(42.4Vpeak)max. 13 N/C OUT.B 13 VIOLET 5Amax.(0-20V), 3.2Amax.(20-30V) 14 14 Common OUT.C Auxiliary Output (Open-Collector) 15 OUT 15 7 16 16 12VDC-COMMON LABEL ON U30 CONTROL TERMINAL ON U30 MAIN HARNESS FUNCTION [SLIDING DOOR] 12VDC+ 12VDC-(COMMON) INTERIOR ACTIVATION HOLDING BEAM REDUCED OPENING SWITCH Mode Switch (see Mode SW Usage shown left) GROUND LUG SCREW TO HEADER BLACK (HOT) WHITE (COMMON) AC115V 10 50/60 H TB1 NR 2 NOISE FILTER POWER SUPPLY P/N 14-11741 TRANSFORMER RELATED DEVICES - 16P NA BC O 5 6 7 POWER SUPPLY 14-14299 BLACK E IT MO E RED BLACK IN ICATORS A 2 ! ! T ! M O O G G SW U M1 Ad ustments to the door can only e made with the NABCO Handy Terminal. A C S 2A O S -C 2L 2 - UNCTION SLI ING OOR C 24 9 1- NO NC C M M1 2 S A SLS OUT A OUT OUT C OU T 1 SYM OL 9 C12 AN Y TERMINAL P MAGNETIC LOCK S P C O 42 4 A -2 A O 12 C- C E R O M 12 C 12 C- C I N 9 1 11 12 1 14 1 1 4 N . 1 2 RELATED DEVICES・16P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 N1 Some magnetic locks (as well other types of locks) require a voltage suppression device such as a diode or MOV. Connect here if needed. Read the instructions provided with the lock for details. To maintain warranty,repairs must e made y authori ed NABCO facilities. Do not disassem le the control ox. There are no user servicea le parts inside. MO E TWO WAY ONE WAY OL OPEN NIG T A NIN M O G G O ! CAUTION GYRO TEC NABCO ! U30 MICROPROCESSOR CONTROL P/N 24-8901-30 MOTOR 12P 1 O ERROR POWER 2P 2 AC MOTOR/OPERATOR P/N 24-11327 2 34 0 7 8 9 10 11 12 1 13-38 POM U WIT MAGNETIC LOCK NOTE LOCK WORKS ONLY IN NIG T MO E 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 Section 13a: U30 with Magnetic Lock CHAPTER 13: ELECTRIC LOCK WIRING Electric Lock Wiring 5 A M P GROUND HARNESS P/N 14-11 72 ON/OFF POWER SWITCH S1 T1 10 11 12 13 14 15 16 1 2 3 4 5 6 7 VIOLET GRAY (OUT A) TERMINAL ON U30 MAIN HARNESS WIRING FOR ELECTRIC LOCK ONLY SHOWN P/N 24-11 77 SYMBOL N . DC12V 1 7 2 61 3 6B 4 5 H M0 6 ) 7 M1 62 S 10 BA 11 SLS 12 OUT.A 13 OUT.B 14 OUT.C 15 OUT 7 16 AUXILIARY 120 VAC POWER WIRES (THESE WIRES NORMALLY COILED AND TIED UP) 120 VAC TB2 MOTOR/OPERATOR P/N 24-11327 OUTPUT TIMER 0 = (DO NOT USE) 1 = (DO NOT USE) 2 = (DO NOT USE) 3 = ELECTRIC STRIKE FUNCTION OUTPUT: 0 = ELECTRIC STRIKE OUTPUT OPENING 3 SEC ON FULLY CLOSED OFF ON CLOSING FULL OPEN FULLY CLOSED 6 1 INDICATORS T D T A . GYRO TECH FAIL SECURE LOCK ASSY. P.N. 22-10522-03 GRY VIO BLK WHT 110V ERROR BA 62 H 6B 61 POWER MOTOR・12P T , z NABCO H T . M N . 24 01- . NABCO . S ( M SW U . FAIL SECURE E A S A B D S P S C O (C 2L 30V(42.4V ) . 5A .(0-20V), 3.2A .(20-30V ) A O (O ) -C 12VDC-(C ) M N/O N/C C SYMBOL N . DC12V 1 2 7 3 61 4 6B 5 H 6) M0 M1 7 62 S BA 10 SLS 11 ) OUT.A 12 OUT.B 13 OUT.C 14 OUT 15 7 16 C HANDY TERMINAL・6P 01-30 SW U M1 MODE O FUNCTION SLIDING DOOR TWO WAY O ONE WAY 12VDC ) G HOLD OPEN 12VDC-(C I A G NIGHT H B R O S , CAUTION M0 O G G O M NABCO WARNING U30 CONTROL P/N 24- DN 0552 10 11 12 13 14 15 16 1 2 3 4 5 6 7 Rev. 10-27-15 OUTPUT TIMER 1.0 SEC OUTPUT SIGNAL ACTIVATION SIGNAL OFF BLACK WHITE POWER SUPPLY HARNESS P/N 14-11 74 U30 ELECTRIC STRIKE OUTPUT SIGNAL HANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER = 3, ROCKER SWITCH SETTING: ONE WAY OR NIGHT MODE E A S A B D S P S C O (C 2L N/O ) 30V(42.4V ) . N/C 5A .(0-20V), 3.2A .(20-30V) C A O (O ) -C 12VDC-COMMON LABEL ON U30 CONTROL FUNCTION SLIDING DOOR 12VDC 12VDC-(COMMON) INTERIOR ACTIVATION HOLDING BEAM REDUCED OPENING SWITCH M S ( M SW U GROUND LUG SCREW TO HEADER AC115V ± 10% 50 / 60 Hz BLACK (HOT) WHITE (COMMON) TB1 ZN R1 R2 ZN NOISE FILTER POWER SUPPLY P/N 14-11741 TRANSFORMER RELATED DEVICES - 16P MADE IN JAPAN DS-150NA GYRO TECH (24-11327) Electric Lock Wiring POWER・2P 20VAC 50/60Hz U30 WITH FAIL SECURE ELECTRIC LOCK NOTE: LOCK WORKS ONLY IN NIGHT MODE & EXIT MODE www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Part #15-9244-30 Section 13b: U30 with Fail Secure Electric Lock 13-39 RELATED DEVICES・16P GROUND HARNESS P/N 14-11872 ON/OFF POWER SWITCH S1 5 A M P T1 TB2 AUXILIARY 120 VAC POWER WIRES (THESE WIRES NORMALLY COILED AND TIED UP) 120 VAC TRANSFORMER OUTPUT TIMER 0 = (DO NOT USE) 1 = (DO NOT USE) 2 = (DO NOT USE) 3 = ELECTRIC STRIKE FUNCTION OUTPUT: 0 = ELECTRIC STRIKE OUTPUT GRAY BLACK FULLY CLOSED OFF OPENING 3 SEC CLOSING FULL OPEN ON FULLY CLOSED VIOLET WHITE POWER SUPPLY HARNESS P/N 14-11874 POM 6 1 INDICATORS WARNING To maintain warranty,repairs must e made y authori ed NABCO facilities. Do not disassem le the control ox. There are no user servicea le parts e made CAUTION HANDY TERMINAL・6P Microprocessor Controller 248901- No. OTHER WIRES NOT SHOWN FOR SIMPLICITY FAIL SAFE RELATED DEVICES・16P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DN 0551 SYMBOL No. 9DC12V 1 7 2 61 3 6B 4 H 5 M0 6 Mode Switch (see Mode SW Usage shown left) M1 7 Exterior Activation 62 8 Sequential Activation SQ 9 Breakout Detector BA 10 Sidelite Presence Sensor SLS 11 Contact Output (Class2 Load only) N/O OUT.A 12 30V(42.4Vpeak)max. N/C OUT.B 13 5Amax.(0-20V), 3.2Amax.(20-30V) Common OUT.C 14 Auxiliary Output (Open-Collector) OUT 15 12VDC-(Common) 7 16 Mode SW Usage M0 M1 MODE Open Open TWO WAY FUNCTION [SLIDING DOOR] Gnd Open ONE WAY 12VDC+ Gnd Gnd HOLD OPEN 12VDC-(Common) Open Gnd NIGHT Interior Activation Holding Beam Reduced Opening Switch To protect against risk of fire or electric shock,use only the certified NABCO power supply. Ad ustments to the door can only with the NABCO Handy Terminal. GYRO TECH FAIL SAFE LOCK ASSY. P.N. 22-10522-04 GRY VIO BLK WHT 110V ERROR BA 62 H 6B 61 POWER MOTOR・12P U30 CONTROL P/N 24-8901-30 Part #15-9244-30 OUTPUT TIMER 1.0 SEC OUTPUT SIGNAL ACTIVATION SIGNAL OFF ON 6 MOTOR/OPERATOR P/N 24-11327 U30 ELECTRIC STRIKE OUTPUT SIGNAL HANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER = 3, ROCKER SWITCH SETTING: ONE WAY OR NIGHT MODE WIRING FOR ELECTRIC LOCK ONLY SHOWN P/N 24-11877 SYMBOL No. 9DC12V 1 1 7 2 2 61 3 3 6B 4 4 5 H 5 6 M0 6 7 M1 7 Exterior Activation 62 8 8 Sequential Activation SQ 9 9 Breakout Detector 10 BA 10 11 Sidelite Presence Sensor SLS 11 Contact Output (Class2 Load only) 12 N/O OUT.A 12 30V(42.4Vpeak)max. 13 FAIL SAFE (OUT B) N/C OUT.B 13 5Amax.(0-20V), 3.2Amax.(20-30V) 14 14 Common OUT.C Auxiliary Output (Open-Collector) 15 OUT 15 7 16 16 12VDC-COMMON LABEL ON U30 CONTROL TERMINAL ON U30 MAIN HARNESS FUNCTION [SLIDING DOOR] 12VDC+ 12VDC-(COMMON) INTERIOR ACTIVATION HOLDING BEAM REDUCED OPENING SWITCH Mode Switch (see Mode SW Usage shown left) GROUND LUG SCREW TO HEADER BLACK (HOT) WHITE (COMMON) A C115V 10 50 / 60 H TB1 2 NR NR 1 NOISE FILTER POWER SUPPLY P/N 14-11741 MADE IN APAN DS-150NA GYRO TECH (24-11327) RELATED DEVICES - 16P 2 34 0 7 8 9 10 11 12 1 13-40 POWER・2P 20VAC 50/60H U30 WITH FAIL SAFE ELECTRIC LOCK NOTE: LOCK WORKS ONLY IN NIGHT MODE & EXIT MODE 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Rev. 10-27-15 Section 13c: U30 with Fail Safe Electric Lock Electric Lock Wiring www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-27-15 Part #15-9244-30 Section 13d: Strike Adjustment For detailed Electric Lock Wiring information and instructions, please refer to; P/N 15-10596-30, U30 Electric Manual”. Electric Lock Assembly LATCHBOLT POSITION: • BIPART UNITS • LH SINGLE F.O. • RH SINGLE F.S. Dead Bolt Engaged with Electric Strike Electric Strike (Door in Full Closed Posion) Slight Gap (Between Strike Wall and Dead Bolt) Belt Clip Terminal Strip (Strike Side of Door) Dead Bolt Assembly LATCHBOLT POSITION: • RH SINGLE F.O. • LH SINGLE F.S. Electric Lock Wiring DN 1026 Figure 13-1 Adjust the Strike 13-41 S1 PRESS TO RESET Common N/O N/C LOAD TWO WAY HOLD OPEN ONE WAY NIGHT OFF ON BACK SIDE OF ROCKER SWITCH SHOWN ROCKER SWITCH FOR U30 PN 14-11875 KEY SWITCH FOR U30 PN 14-11876 FULL OPEN ORANGE RED ORG/WHT RED GREEN ORG/WHT RED ORANGE WHITE WHITE U30 TERMINAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 MAGNETIC POWER DOWN SWITCH P/N 22-9222 WHITE BLUE BLUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WHITE RED RED ORG/WHT BLUE GREEN ORANGE BLUE BROWN RED BLACK WHITE GREEN ORANGE ORG/WHT BLK/RED YELLOW BLUE GRN/WHT MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 GYRO TECH NABCO NABCO NA BC O 1211 7 0 1 ! ! ! WARNING M0 Open Gn d Gn d Open Mode SW Usage MODE M1 Open TWO WAY Open ONE WAY Gn d HOLD OPEN Gn d NIGH T To protect against risk of Fire or electric shock,use only the cerfied NABCO power supply. To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION GYRO TECH ! NABCO Exterio r Acvaon Sequenal Acvaon Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) Mode Switch (see Mode SW Usage shown le) 12VDC + 12VDC-(Common) Interior Acvao n Holding Beam Reduced Opening Switch FUNCTION (SLIDING DOOR) ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED U30 TERMINAL P/N 24-11877 DN 0539 OPTEX HOLDING BEAM CONTROLLER PT. NO. PN 14-9710-03 TERM #1 BROWN &RED (CIRCUIT 1 & 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Optex OS-12C Controller RED TERM #4 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WHITE TERM #5 EXTERIOR ACUSENSOR PT. NO. 14-8902 YELLOW GRAY BROWN BLK/RED P/N 14-11874 N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT. A OUT. B OUT. C OU T 7 HANDY TERMINAL 6P Microprocessor Controller 248901- No. Power Harness ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED INTERIOR ACUSENSOR PT. NO. 14-8902 YELLOW GRAY BROWN BLK MAIN HARNESS FOR U30 P/N 24-11877 ERROR BA 62 H 6B 61 POWER MOTOR 12P U30 MICROPROCESSOR CONTROL P/N 24-8901-30 Part #15-9244-30 REDUCED OPEN RED BLUE WHITE WHITE BLUE TB2 Auxiliary 120 VAC Power Wires (These wires are normally POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROL LABEL Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common Mode Switch Holding Beam Reduced Opening Switch -CIRCUIT-BREAKERRED INDICATES POWER IS OFF T1 8 12 VDC+ 12VDC- (Common) P/N 14-11872 TB1 NOISE FILTER ON/OFF Power Switch PE Grounding Wire (Common) White Wire AC115V ± 10% 50 / 60 Hz MOTOR/OPERATOR P/N 24-11327 3 2 4 INDICATORS POWER 2P 20VAC 50/60Hz POWER SUPPLY P/N 14-11741 RELATED DEVICES・16P 14-42 N 7 6 5 L 10 9 Related Devices - 16P >POM < Black Wire (Hot) 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Rev. 10-27-15 CHAPTER 14: GENERAL WIRING 14.1 (2) Acusensors and (1) Holding Beam General Wiring General Wiring Common N/O N/C LOAD TWO WAY FULL OPEN ORANGE RED REDUCED OPEN RED ORG/WHT RED GREEN ORG/WHT RED ORANGE BLUE WHITE WHITE BLUE WHITE WHITE U30 TERMINAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 MAGNETIC POWER DOWN SWITCH P/N 22-9222 WHITE BLUE BLUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NABCO WHITE RED RED ORG/WHT BLUE GREEN ORANGE BLUE BROWN RED BLACK WHITE GREEN ORANGE ORG/WHT BLK/RED YELLOW BLUE GRN/WHT MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 GYRO TECH NABCO NA BC 3 2 1 1211 7 0 ! ! M0 Open Gn d Gn d Open Mode SW Usage MODE M1 Open TWO WAY Open ONE WAY Gn d HOLD OPEN NIGH T Gn d ! WARNING To protect against risk of Fire or electric shock,use only the cerfied NABCO power supply. To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION GYRO TECH NABCO GRAY WHITE GRAY ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED U30 TERMINAL P/N 24-11877 DN 0685 OPTEX HOLDING BEAM CONTROLLER PT. NO. PN 14-9710-03 TERM #1 BROWN &RED (CIRCUIT 1 & 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Optex OS-12C Controller RED TERM #4 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WHITE TERM #5 N/O N/C Common EXTERIOR OPTEX I-1 PT. NO. 14-13036 YELLOW GRAY YELLOW Mode Switch (see Mode SW Usage shown le) Exterio r Acvaon Sequenal Acvaon Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT. A OUT. B OUT. C OU T 7 HANDY TERMINAL 6P Microprocessor Controller 248901- No. FUNCTION (SLIDING DOOR) 12VDC + 12VDC-(Common) Interior Acvao n Holding Beam Reduced Opening Switch BLK BROWN BLK/RED OPTEX HARNESS P/N 12-13018 WHITE GRAY ERROR BA 62 H 6B ! MOTOR 12P 61 POWER Power Harness P/N 14-11874 ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED INTERIOR OPTEX I-1 PT. NO. 14-13036 YELLOW GRAY YELLOW GRAY BROWN BLK MAIN HARNESS FOR U30 P/N 24-11877 O U30 MICROPROCESSOR CONTROL P/N 24-8901-30 Rev. 10-27-15 HOLD OPEN ONE WAY NIGHT OFF ON BACK SIDE OF ROCKER SWITCH SHOWN ROCKER SWITCH FOR U30 PN 14-11875 KEY SWITCH FOR U30 PN 14-11876 TB2 Auxiliary 120 VAC Power Wires (These wires are normally POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 T1 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROL LABEL Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common Mode Switch Holding Beam Reduced Opening Switch S1 PRESS TO RESET RED INDICATES POWER IS OFF -CIRCUIT-BREAKER- NOISE FILTER ON/OFF Power Switch TB1 MOTOR/OPERATOR P/N 24-11327 RELATED DEVICES・16P POWER SUPPLY P/N 14-11741 8 12 VDC+ 12VDC- (Common) Grounding Wire P/N 14-11872 White Wire (Common) AC115V ± 10% 50 / 60 Hz PE 4 INDICATORS POWER 2P 20VAC 50/60Hz N 7 6 5 L 10 9 Related Devices - 16P >POM < Black Wire (Hot) www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Part #15-9244-30 14.2 (2) Optex i-One Sensors, (1) Holding Beam and (1) Breakout Beam 14-43 S1 PRESS TO RESET RED INDICATES POWER IS OFF -CIRCUIT-BREAKER- N/O N/C Common TWO WAY HOLD OPEN ONE WAY NIGHT OFF ON BACK SIDE OF ROCKER SWITCH SHOWN ROCKER SWITCH FOR U30 PN 14-11875 KEY SWITCH FOR U30 PN 14-11876 FULL OPEN ORG/WHT RED GREEN ORG/WHT RED ORANGE WHITE WHITE WHITE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ROCKER SWITCH EXTENSION HARNESS FOR U30 PN 14-11884 BLUE RED RED ORG/WHT BLUE GREEN ORANGE BROWN RED BLACK WHITE GREEN ORANGE ORG/WHT BLK/RED YELLOW BLUE GRN/WHT WHITE U30 TERMINAL MAGNETIC POWER DOWN SWITCH P/N 22-9222 WHITE BLUE BLUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 GY RO TECH NABCO NA O BC 1 12 11 7 0 43 2 MOTOR/OPERATOR P/N 24-11327 ERROR BA 62 H 6B 61 Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION Mode SW Usage MODE M0 M1 Open Open TWO WAY Open Gnd ONE WAY GndG nd HOLD OPEN Open Gnd NIGHT To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. FUNCTION [SLIDING DOOR] Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 HANDY TERMINAL・6P Microprocessor Controller 248901- No. 12VDC+ 12VDC-(Common) No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WHITE GRAY ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED BLUE (TERM #4) BLUE (TERM #3) U30 TERMINAL P/N 14-11873 TERM #1 TERM #1 BROWN &RED (TERM 1 & 2) DN 0542 OPTEX OPTEX HOLDING BEAM BREAKOUT BEAM CONTROLLER CONTROLLER PT. NO. PT. NO. PN 14-9710-03 PN 14-9710-03 Optex OS-12C Controller BROWN &RED (TERM 1 & 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Optex OS-12C Controller RED TERM #4 WHITE TERM #5 EXTERIOR OPTEX I-ONE PN 14-10364-A YELLOW GRAY YELLOW GRAY BROWN BLK/RED OPTEX HARNESS PN 12-13018 WHITE GRAY ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED INTERIOR OPTEX I-ONE PN 14-10364-A YELLOW GRAY YELLOW GRAY BROWN BLK MAIN HARNESS FOR U30 P/N 24-11877 ! WARNING To protect against risk of fire or electric shock,use only the certified NABCO power supply. RELATED DEVICES・16P U30 MICROPROCESSOR CONTROLLER P/N 24-8901-30 ! ! ! NABCO GYRO TECH MOTOR・12P POWER Power Harness P/N 14-11874 NABCO Part #15-9244-30 ORANGE RED REDUCED OPEN RED BLUE WHITE BLUE TB2 Auxiliary 120 VAC Power Wires (These wires are POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 T1 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROLLER LABEL Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common Mode Switch Holding Beam Reduced Opening Switch 12 VDC+ 12VDC- (Common) P/N 14-11872 PE ON/OFF Power Switch TB1 NOISE FILTER 8 Grounding Wire (Common) White Wire AC115V ± 10% 50 / 60 Hz LOAD POWER SUPPLY P/N 14-11741 INDICATORS POWER・2P 20VAC 50/60Hz 14-44 N 7 65 L 10 9 Related Devices - 16P >POM < Black Wire (Hot) 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Rev. 10-27-15 14.3 (2) Optex i-One Sensors, (1) Holding Beam and (1) Breakout Beam General Wiring General Wiring -CIRCUIT-BREAKER- S1 PRESS TO RESET RED INDICATES POWER IS OFF Common N/O N/C LOAD TWO WAY FULL OPEN ORANGE RED REDUCED OPEN RED ORG/WHT RED GREEN ORG/WHT RED ORANGE BLUE WHITE WHITE ROCKER SWITCH EXTENSION HARNESS FOR U30 P/N 14-11884 MAGNETIC POWER DOWN SWITCH P/N 22-9222 WHITE BLUE BLUE RED RED ORG/WHT BLUE GREEN ORANGE BROWN RED BLACK WHITE GREEN ORANGE ORG/WHT BLK/RED YELLOW BLUE GRN/WHT WHITE U30 TERMINAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 GY RO TECH NABCO NABCO O BC 7 0 11 1 12 INDICATORS ERROR BA 62 H 6B ! WARNING To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION Mode SW Usage M0 M1 MODE Open Open TWO WAY Open ONE WAY Gnd GndG nd HOLD OPEN Open NIGHT Gnd To protect against risk of fire or electric shock,use only the certified NABCO power supply. Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) 12VDC-(Common) 12VDC+ FUNCTION [SLIDING DOOR] N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 HANDY TERMINAL・6P Microprocessor Controller 248901- No. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 BLUE (TERM #4) BLUE (TERM #3) U30 TERMINAL P/N 14-11873 OPTEX OS-12C Controller TERM #1 TERM #1 BROWN &RED (TERM 1 & 2) OPTEX OS-12C Controller BROWN &RED (TERM 1 & 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DN 0541 OPTEX OPTEX HOLDING BEAM BREAKOUT BEAM CONTROLLER CONTROLLER PT. NO. PT. NO. P/N 14-9710-03 P/N 14-9710-03 ACUSENSOR EXTENSION HARNESS P/N 22-9267-00 RED RED WHITE (TERM #5) RED (TERM #4) EXTERIOR ACUSENSOR P/N YELLOW GRAY BROWN BLK/RED WHITE Power Harness (P/N 14-11874) ! ! ! NABCO GYRO TECH MOTOR・12P 61 POWER ACUSENSOR EXTENSION HARNESS P/N 22-9267-00 RED RED INTERIOR ACUSENSOR P/N YELLOW GRAY BROWN BLK Main Harness For U30 P/N 24-11877 NA RELATED DEVICES・16P U30 MICROPROCESSOR CONTROLLER P/N 24-8901-30 Rev. 10-27-15 HOLD OPEN ONE WAY NIGHT OFF ON BACK SIDE OF ROCKER SWITCH SHOWN ROCKER SWITCH FOR U30 P/N 14-11875 KEY SWITCH FOR U30 P/N 14-11876 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 BLUE 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROLLER LABEL Mode Switch (See Mode SW Usage Shown Le ) Exterior Ac va on al Ac va on Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common TB2 Auxiliary 120 VAC Power Wires (These wires are normally coiled and ed up) POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 T1 8 12 VDC+ 12VDC- (Common) Interior Ac va on Holding Beam Reduced Opening Switch P/N 14-11872 TB1 NOISE FILTER ON/OFF Power Switch PE Grounding Wire (Common) White Wire AC115V ± 10% 50 / 60 Hz MOTOR/OPERATOR P/N 24-11327 32 4 N POWER・2P 20VAC 50/60Hz L 7 65 POWER SUPPLY P/N 14-11741 < 10 9 Related Devices - 16P >POM Black Wire (Hot) www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Part #15-9244-30 14.4 (2) Acusensors, (1) Holding Beam and (1) Breakout Beam 14-45 S1 PRESS TO RESET RED INDICATES POWER IS OFF -CIRCUIT-BREAKER- N/O N/C Common TWO WAY HOLD OPEN ONE WAY NIGHT OFF ON BACK SIDE OF ROCKER SWITCH SHOWN ROCKER SWITCH FOR U30 PN 14-11875 KEY SWITCH FOR U30 PN 14-11876 FULL OPEN ORG/WHT RED GREEN ORG/WHT RED ORANGE WHITE WHITE WHITE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 BLUE RED RED ORG/WHT BLUE GREEN ORANGE O BC 1 12 11 7 0 MOTOR/OPERATOR P/N 24-11327 ERROR BA 62 H YELLOW BLACK BLUE GREEN On Remote Control Set: “F1” to “1” If programming without the Remote: Parameter “13” to “1” RED BROWN WHITE ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED INTERIOR IXIO PN 14-14264 GRAY BROWN BLK MAIN HARNESS FOR U30 P/N 24-11877 ! WARNING To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION Mode SW Usage MODE M0 M1 Open Open TWO WAY Open Gnd ONE WAY GndG nd HOLD OPEN Open Gnd NIGHT To protect against risk of fire or electric shock,use only the certified NABCO power supply. FUNCTION [SLIDING DOOR] Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 HANDY TERMINAL・6P Microprocessor Controller 248901- No. 12VDC+ 12VDC-(Common) No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RELATED DEVICES・16P BLACK BLUE GREEN YELLOW RED BROWN WHITE ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED BLUE (TERM #4) BLUE (TERM #3) U30 TERMINAL P/N 14-11873 Optex OS-12C Controller TERM #1 TERM #1 BROWN &RED (TERM 1 & 2) Optex OS-12C Controller BROWN &RED (TERM 1 & 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DN 0555 OPTEX OPTEX HOLDING BEAM BREAKOUT BEAM CONTROLLER CONTROLLER PT. NO. PT. NO. PN 14-9710-03 PN 14-9710-03 WHITE TERM #5 EXTERIOR IXIO PN 14-14264 GRAY BROWN BLK/RED RED TERM #4 U30 MICROPROCESSOR CONTROLLER P/N 24-8901-30 ! ! ! NABCO GYRO TECH MOTOR・12P 6B 61 POWER Power Harness P/N 14-11874 NA 43 2 White and Green wires from Sensor provide output for ROCKER SWITCH EXTENSION HARNESS FOR U30 PN 14-11884 MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 BROWN RED BLACK WHITE GREEN ORANGE ORG/WHT BLK/RED YELLOW BLUE GRN/WHT WHITE U30 TERMINAL MAGNETIC POWER DOWN SWITCH P/N 22-9222 WHITE BLUE BLUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NABCO GY RO TECH NABCO Part #15-9244-30 ORANGE RED REDUCED OPEN RED BLUE WHITE BLUE TB2 Auxiliary 120 VAC Power Wires (These wires are POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 T1 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROLLER LABEL Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common Mode Switch Holding Beam Reduced Opening Switch 12 VDC+ 12VDC- (Common) P/N 14-11872 PE ON/OFF Power Switch TB1 NOISE FILTER 8 Grounding Wire (Common) White Wire AC115V ± 10% 50 / 60 Hz LOAD POWER SUPPLY P/N 14-11741 INDICATORS POWER・2P 20VAC 50/60Hz 14-46 N 7 65 L 10 9 Related Devices - 16P >POM < Black Wire (Hot) 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Rev. 10-27-15 14.5 (2) IXIO, (1) Holding Beam and (1) Breakout Beam General Wiring General Wiring S1 PRESS TO RESET RED INDICATES POWER IS OFF -CIRCUIT-BREAKER- N/O N/C Common TWO WAY HOLD OPEN ONE WAY NIGHT OFF ON BACK SIDE OF ROCKER SWITCH SHOWN ROCKER SWITCH FOR U30 PN 14-11875 KEY SWITCH FOR U30 PN 14-11876 FULL OPEN ORANGE RED ORG/WHT RED GREEN ORG/WHT RED ORANGE WHITE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WHITE BLUE RED RED ORG/WHT BLUE GREEN ORANGE O BC 11 7 0 1 12 MOTOR/OPERATOR P/N 24-11327 H ERROR BA 62 YELLOW BLACK BLUE GREEN On Remote Control Set: “F1” to “1” If programming without the Remote: Parameter “13” to “1” RED BROWN WHITE ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED INTERIOR IXIO PN 14-14264 GRAY BROWN BLK MAIN HARNESS FOR U30 P/N 24-11877 ! WARNING To maintain warranty,repairs must be made by authorized NABCO facilities. Do not disassemble the control box. There are no user serviceable parts inside. Adjustments to the door can only be made with the NABCO Handy Terminal. ! CAUTION Mode SW Usage MODE M0 M1 Open Open TWO WAY Open Gnd ONE WAY GndG nd HOLD OPEN Open Gnd NIGHT To protect against risk of fire or electric shock,use only the certified NABCO power supply. FUNCTION [SLIDING DOOR] Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 HANDY TERMINAL・6P Microprocessor Controller 248901- No. 12VDC+ 12VDC-(Common) No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RELATED DEVICES・16P BLACK BLUE GREEN YELLOW GRAY BROWN BLK/RED EXTERIOR IXIO PN 14-14264 RED BROWN WHITE ACUSENSOR EXTENSION HARNESS PN 22-9267-00 RED RED U30 TERMINAL P/N 14-11873 Optex OS-12C Controller TERM #1 BROWN &RED (c IRc UIt 1 & 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DN 0554 OPTEX HOLDING BEAM CONTROLLER PT. NO. PN 14-9710-03 WHITE TERM #5 RED TERM #4 U30 MICROPROCESSOR CONTROLLER P/N 24-8901-30 ! ! ! NABCO GYRO TECH MOTOR・12P 6B 61 POWER Power Harness P/N 14-11874 NA 43 2 White and Green wires from Sensor provide output for ROCKER SWITCH EXTENSION HARNESS FOR U30 PN 14-11884 MADE IN JAPAN Nabtesco Corporation DS-1500 D24-113270 BROWN RED BLACK WHITE GREEN ORANGE ORG/WHT BLK/RED YELLOW BLUE GRN/WHT WHITE U30 TERMINAL MAGNETIC POWER DOWN SWITCH P/N 22-9222 WHITE BLUE BLUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NABCO GY RO TECH NABCO Rev. 10-27-15 REDUCED OPEN RED BLUE WHITE WHITE TB2 Auxiliary 120 VAC Power Wires (These wires are POWER SUPPLY ASSEMBLY P/N 9418800100 NABCO ENTRANCES, INC. 14-11741 T1 9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7 U30 MICROPROCESSOR CONTROL LABEL Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V (42.4V peak) max. 5A max, (0-20V), 3.2A max. (20-30V) Auxiliary Output (Open Collector) 12VDC Common Mode Switch Holding Beam Reduced Opening Switch 12 VDC+ 12VDC- (Common) P/N 14-11872 PE ON/OFF Power Switch TB1 NOISE FILTER 8 Grounding Wire (Common) White Wire AC115V ± 10% 50 / 60 Hz LOAD POWER SUPPLY P/N 14-11741 INDICATORS POWER・2P 20VAC 50/60Hz N 7 65 L 10 9 Related Devices - 16P >POM < Black Wire (Hot) www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Part #15-9244-30 14.6 (2) IXIO, and (1) Holding Beam 14-47 1175 Standard Slide Doors Installation Manual www.NabcoEntrances.com Part #15-9244-30 Rev. 10-27-15 CHAPTER 15: HANDING WHEN VIEWED FROM BREAKOUT SIDE TYPICALLY EXTERIOR Full Open Units: Doors slide behind Sidelite Fixed Sidelite Units: Doors slide in front of Sidelite Le Hand: Door slides to the Le Right Hand: Door slides to the Right Le Hand Right Hand DN 1381 15.a Test the Handing 1. Turn Power OFF. 2. Manually slide the Slide door half way open. 3. Turn Power ON. The Slide door should slowly close (per Power On factory settings). 15.b Install the Handing Harness 1. Turn Power OFF. 2. Obtain the Handy Terminal Harness. Plug the Telephone Jack end into the U30 Microprocessor Control. Remove the Protective Cap from the female end. 3. Obtain the Cable. Slide back the metal sleeve on the male end of the Cable. Connect the Cable to the female end of the Handy Terminal Harness. a. The male end of the Cable has multiple prongs that must line up with the socket. Gently turn the plug end clockwise while trying to insert the male end until a connection can be made. 4. Connect the other end of the Cable to the Handy Terminal. Turn Power ON. 5. Press: ENTRY until the screen displays: SPECIAL FUNCTION ADJUSTMENTS Then select: Y 6. Continue pressing: ENTRY until the Screen displays: RECYCLE Change the setting Y/N. 7. Disconnect the Handy Terminal. a. Wait at least (10) seconds before disconnecting Handy Terminal to allow last test to complete and message display to stabilize. 15-48 8. Turn Power OFF. Handing www.NabcoEntrances.com 1175 Standard Slide Doors Installation Manual Rev. 10-27-15 Part #15-9244-30 9. Manually slide the Slide door half way open. 1. Turn Power ON. 2. The Slide door should slowly close (per Power ON factory settings). 3. Plug the Handy Terminal back into the Terminal Connector. Handy Terminal Harness P/N M-01517 INDICATORS GYRO TECH 6B H POWER・2P 20VAC 50/60Hz M0 Open Gnd Gnd Open Mode SW Usage MODE M1 Open TWO WAY Open ONE WAY Gnd HOLD OPEN NIGHT Gnd ! CAUTION 62 BA ERROR To protect against risk of fire or electric shock,use only the certified NABCO power supply. ! NABC O 61 ! Adjustments to the door can only be made with the NABCO Handy Terminal. Do not disassemble the control box. There are no user serviceable parts inside. ! To maintain warranty,repairs must be made by authorized NABCO facilities. HANDY TERMINAL・6P No. Microprocessor Controller 248901FUNCTION [SLIDING DOOR] 12VDC+ 12VDC-(Common) Interior Activation Holding Beam Reduced Opening Switch Mode Switch (see Mode SW Usage shown left) Exterior Activation Sequential Activation Breakout Detector Sidelite Presence Sensor Contact Output (Class2 Load only) 30V(42.4Vpeak)max. 5Amax.(0-20V), 3.2Amax.(20-30V) Auxiliary Output (Open-Collector) 12VDC-(Common) N/O N/C Common SYMBOL 9DC12V 7 61 6B H M0 M1 62 SQ BA SLS OUT.A OUT.B OUT.C OUT 7 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RELATED DEVICES・16P ! WARNING MOTOR・12P POWER Handy Terminal P/N V-00356 U30 Microprocessor Control P/N V-00020 DN 1367 Handing Remove Protecve Cap from the Handy Terminal Harness Cable P/N M-01410 Figure 10-1 Connect the Handy Terminal to the U30 Microprocessor Control 15-49