Sample gas probe GAS 222.17

Transcription

Sample gas probe GAS 222.17
Sample gas probe GAS 222.17
Technical data:
Flow Diagram
! Material: 1.4571
! Seals: Graphite/1.4404 and see filter elements
! Operating temperature: max. 395°F
! Max. working pressure: 85 psig
! Voltage: 115/230 V, 50/60Hz
! Temperature: Self-regulating 355°F
! Low temperature alarm
Contact is open at operating temperature
Closes at < 285°F, current max. 4A
Description:
! Heated sample gas probe with downstream filter
! Ambient temperature: -5 to 175°F
and weather protection shield
! Filter can be replaced without tools
Order information: Base unit:
! Effective insulation and protection shield
! GAS 222.17 p/n 4622217
! Self-regulating up to 355°F with low temperature
alarm
! Dust concentration up to 2 g/m³
! Not for hazardous areas
Options:
To customize the base unit to meet the needs of any
application, please refer to data sheet DA461099
"Accessories for Gas Sample Probes.”
! Various probe tubes
! Unheated extensions
! Filters
! Calibration gas port
! ANSI flange 3"
For general information see data sheet "Gas Sample Probes GAS 222" DA 461000.
DA 46 1017
12/2006
Buhler Technologies LLC
1030 West Hamlin Road, Rochester Hills, MI 48309
Phone: 248.652.1546
Fax: 248.652.1598
Internet: www.buhlertech.com
e-mail: [email protected]