ISIS™ inDASH MAX Dash Indicator Module Manual Table of Contents

Transcription

ISIS™ inDASH MAX Dash Indicator Module Manual Table of Contents
ISIS™inDASHMAXDashIndicatorModuleManual
TableofContents
Overview .......................................................................................................................................... 2 Module Details ................................................................................................................................ 3 Technical Specifications: ................................................................................................................. 3 Kit Includes ...................................................................................................................................... 3 Installation Steps ............................................................................................................................. 4 Connect Power & Ground Harness to inDASH MAX Module ...................................................... 4 Connect the inDASH MAX module to the ISIS CAN network. ...................................................... 4 Connect the inDASH MAX module to indicator lights. ................................................................ 6 Powering Up the System ................................................................................................................. 8 Warranty Information ..................................................................................................................... 9 Contact Information ...................................................................................................................... 10 1
Rev0‐01/2012
Overview
TheISIS™inDASHMAXDashLightingControllerisanexpansionmoduletotheISIS
IntelligentMultiplexSystemthatgivesvehiclefabricatorsaneasywaytocontrolthe
indicatorsandilluminationontheirdashboards.Thisgivesyouasimplewayto
wiretheturn‐signalindicators,high‐beamindicatorsandgaugeillumination,all
fromasimplemodulepluggedintotheISISIntelligentMultiplexSystem.
CommandsaresentfromtheISISMASTERCELLtoinDASHMAXtoactivatethe
LED’sorsmallincandescentbulbsinyourgaugecluster.Thisgetsyouavery
flexiblesystemthatiseasytoexpandanduseslesswirethanothersolutionsonthe
market.CommandsareautomaticallysentfromtheMASTERCELLwhentheturn
signals,high‐beamsorparkinglightswitchesareactivated.Theindicatorsare
managedfromwithininDASHMAX.
2
Rev0‐01/2012
ModuleDetails




Plug&PlaymodulethatconnectsintoanexistingL1orL2systemtodrive
LEDlightingforvehicle.(Oldersystemconfigurationsmayhavetobe
updatedtocommunicatewithinDASHMAX.)
Compactmodulewithintegratedmountingtabsforeasyinstallation.
Applicationsincludeaccentandmoodlightinginlimousines,partybusses,
hotrodsandmore.
6low‐sideswitchedoutputchannels.
TechnicalSpecifications:






Dimensions:5”X2”X1”
Numberofoutputchannels:6
Maximumcurrentdrawperchannel:1.0‐amp.
Operatingvoltage:11.0to14.8‐volts.
EachinDASHMAXmoduleisindividuallyaddressed.
Dimensions:5”X2”X1”
NOTE:DonotexceedthemaximumspecifiedcurrentdrawoninDASHMAX
outputchannels.
KitIncludes
1‐ISIS™inDASHMAXControllerModule
1‐Power&GroundHarnesswithFuseHolder
1‐ISIS™inDASHMAXOutputHarness
1‐ModularISIS™CANJumperHarnesses
6‐22‐AWGButtSpliceTerminals
6‐PiecesofHeatShrinkTubing
1‐InstructionManual
3
Rev0‐01/2012
InstallationSteps
ConnectPower&GroundHarnesstoinDASHMAXModule
1) Removethepositiveterminalfromyourbatteryorbatteriesbeforeinstalling
anyelectricalcomponents.
2) ConnecttheRed22‐AWGwireintheharnesswiththerectangular4‐position
connectortoaconstantbatteryfeed.SplicetheincludedMini™fuseholderin
serieswiththiswire,keepingthefuseholderasclosetothebatteryas
possible.AgoodplacetopickupthisfeedistheMega™fuseholderincluded
withyourISISkit.
3) ConnecttheBlack22‐AWGwireintheharnesswiththerectangular4‐
positionconnectortochassisground.Makesurethatyouhaveagoodmetal‐
to‐metalconnectiontoground.
ConnecttheinDASHMAXmoduletotheISISCANnetwork.
1) PickaconvenientplaceintheISISCANcabletospliceintoforinDASHMAX.
2) Removetheconvoluteloomingfromtheareawhereyouwillmakethesplice.
3) Cutandstripthe6wiresintheinDASHMAXCANjumperharnesstotheright
lengthtospliceintoyourexistingISISCANharness.
4) Locatethepairofblue*22‐AWGwiresintheCANharness.Pickoneofthe
bluewiresandcutit.Bothofthebluewiresareelectricallythesamesoyou
maychooseeitherbluewire.
5) Stripbacktheinsulationonbothsidesofthecutblue22‐AWGwire.
6) Sliponepieceofheat‐shrinktubingoneachendofthecutblue22‐AWGwire
intheexistingCANharness.
7) Crimponeendoftheincludedbutt‐spliceterminalstoeachofthecutendsin
theexistingCANharness.
8) Crimptheotherendsofthebutt‐spliceterminalstothebluewiresinthe
inDASHMAXCANjumperharness.Thesewiresareelectricallythesamesoit
doesnotmatterwhichofthebluewiresconnecttothebluewiresinyour
existingCANharness.
9) Locatethepairofgreen*22‐AWGwiresintheCANharness.Pickoneofthe
greenwiresandcutit.Bothofthegreenwiresareelectricallythesameso
youmaychooseeithergreenwire.
10)Stripbacktheinsulationonbothsidesofthecutgreen22‐AWGwire.
11)Sliponepieceofheat‐shrinktubingoneachendofthecutgreen22‐AWG
wireintheexistingCANharness.
4
Rev0‐01/2012
12)Crimponeendoftheincludedbutt‐spliceterminalstoeachofthecutendsin
theexistingCANharness.
13)Crimptheotherendsofthebutt‐spliceterminalstothegreenwiresinthe
inDASHMAXCANjumperharness.Thesewiresareelectricallythesamesoit
doesnotmatterwhichofthegreenwiresconnecttothegreenwiresinyour
existingCANharness.
14)Locatetheblack*22‐AWGwireintheCANharness.
15)Stripbacktheinsulationonbothsidesofthecutblack22‐AWGwire.
16)Sliponepieceofheat‐shrinktubingoneachendofthecutblack22‐AWG
wireintheexistingCANharness.
17)Crimponeendoftheincludedbutt‐spliceterminalstoeachofthecutendsin
theexistingCANharness.
18)Crimptheotherendsofthebutt‐spliceterminalstotheblackwiresinthe
inDASHMAXCANjumperharness.Thesewiresareelectricallythesamesoit
doesnotmatterwhichoftheblackwiresconnecttotheblackwiresinyour
existingCANharness.
19)Slidethepiecesofheat‐shrinktubingoverthebutt‐splicesintheharness.
20)Useaheat‐guntoshrinkthetubingoverthesplices.
21)Re‐loomtheCANcable.
22)Plugthe3‐positionrectangularconnectorintoeitherofthesocketslabeled
CANontheinDASHMAXmodule.
*Note:SomegenerationsofISISCANcablemayhavedifferentwirecolors.Please
contactISISPowertechnicalsupportifyourwirecolorsdonotmatchtheones
describedabove.
5
Rev0‐01/2012
ConnecttheinDASHMAXmoduletoindicatorlights.
1) inDASHisdesignedtogroundswitchasmalllightorthecathodesideofa
lightemittingdiode.Thedifferentcoloredwiresontheoutputharnessare
assignedtospecificindicatorsforyourdash.SeeTable1forthewirecolors.
a. LeftTurnSignal‐indicatorwillflashwhentheleftturnsignalsare
flashing.
b. RightTurnSignal‐indicatorwillflashwhentherightturnsignalsare
flashing.
c. Boththeleft&rightturnsignalindicatorswillflashtogetherwhenthe
4‐waysareon.
d. High‐Beamindicatorwillturnonwhenthehigh‐beamoutputis
active.
e. GaugeIlluminationoutputwillbeactivewhentheparkinglightsare
turnedon.
f. SecurityIndicatorwillflashwhenISISsecurityissetfrominLINKor
inTOUCHMobile.
g. ISISStatuswillturnonsolidwhentheISISnetworkstatusisokay.It
willflashtoindicateanyproblemsontheISISbus.Checkyour
inSIGHTmodulesformessagesifthislightflashes.NOTE:thisoutput
isoptional.
2) SetthenumberontherotarydialontherearofinDASHMAXtotheaddress
specifiedonyourISISConfigurationSheet.Thedefaultaddressis“5”.
3) ConnecttheRed22‐AWGwireintheinDASHMAXoutputharnesstooneside
ofyourlights.IfyouareusingLED’s,thiswireshouldconnecttotheanode
side.
4) ConnecttheotherwiresintheinDASHMAXoutputharnesstoyour
indicatorsusingFigure1.
6
Rev0‐01/2012
Table1:WireColorDefinitionsforinDASHMAXOutputHarness
WireColor
Description
Pink/Red
FusedPowerfrominDASHMAX
Brown
LeftTurnSignalIndicator
Purple
RightTurnSignalIndicator
Blue
High‐BeamIndicator
Yellow
GaugeIllumination
Pink
SecurityActiveIndicator
Grey
ISISStatusOkayIndicator
N
R
U
T
TF
EL
inDASH MAX
N
R
U
TT
H
G
I
R
M
A
E
B
‐
H
G
I
H
E
G
U
A
G
N
O
I
T
A
IN
M
U
LL
I
Y
IT
R
U
C
ES
S
U
T
A
TS
S
IS
I
NOTE: Wire locations in this drawing for illustrative purposes only. Actual wire locations in the harness may not match the locations shown. Figure1:WiringSchematicforISISinDASHMAX.
7
Rev0‐01/2012
PoweringUptheSystem
1) Reconnectthebatterytothesystem.
2) inDASHMAXwillflashatestpatternonthedifferentindicatorstoindicate
thatitisconnectedproperly.
3) ChecktoseeiftheISISinDASHMAXmoduleisinsysteminventory.
a. FromaMASTERCELLwiththeinSIGHTLCD
i. Pressthe“HOME”button
ii. Pressthe“SCROLLDOWN”button
iii. inDASHMAXisinstalledcorrectlyifyousee“CELLAXRGB‐6
Ch”inthesysteminventory.TheXafterCELLAcorresponds
totheaddresssetoninDASHMAX.
b. FromaMASTERCELLwithinTOUCHMAX
i. Pressthe“TOOLS”buttononthemainscreen.
ii. PressISIS01ENDonthetouchscreenkeypad.
iii. inDASHMAXisinstalledcorrectlyifyousee“ISISLED
Controller6ChVer1”inthesysteminventory.
8
Rev0‐01/2012
WarrantyInformation
WarrantyforISIS™IntelligentMultiplexSystem™
Infinitybox, LLC (“Infinitybox”) warrants against any defects in materials and
workmanship to the Product’s ISIS™ modules, wiring harnesses and accessory
modulesforaperiodofone(1)yearfromthefirstdateofpurchase.Subjecttothe
termsofthiswarrantydescribedbelow,Infinityboxwillreplaceanysuchdefective
Product that is returned to Infinitybox within the one (1) year period from initial
purchase. Replacement of any defective part or Product will not extend the
applicablewarrantyperiod.
Thewarrantydoesnotapplyto:(i)anyProductthatisnotinstalledincompliance
with the applicable Product documentation; (ii) any defect in, or failure of, the
Productresultingfromanaccident,shock,negligence,waterimmersionormisuse;
(iii)anyProductthathasbeenmodified,adjusted,repaired,ordisassembledbyany
party other than Infinitybox; or (iv) any defect other than in materials and
workmanship.
This warranty covers only the original purchaser of Product purchased from an
Infinitybox authorized dealer in the United States. In order to receive warranty
service, purchaser must provide Infinitybox with a copy of the receipt stating the
dealer name, product purchased and date of purchase. Products found to be
defectiveduringthewarrantyperiodwillbereplaced(withaproductdeemedtobe
equivalentorbetter)atthediscretionofInfinitybox.
Infinitybox’s sole liability for any defective Product is limited solely to the
replacementofProductpursuanttothiswarranty.Infinityboxreservestherightto
replaceanyrepairablepartswithneworrefurbishedparts.
INFINITYBOXDISCLAIMSALLOTHERWARRANTIES,WHETHEREXPRESS,IMPLIED
OR STATUTORY, SUCH AS WARRANTIES OF MERCHANTABILITY AND FITNE SS
FORPURPOSE.INNOEVENTSHALLINFINITYBOXBELIABLEFORANYPUNITIVE,
INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT
LIMITATION, LIABILITY FOR LOSS OF USE, LOSS OF PROFITS, LOSS OF PRODUCT
ORBUSINESSINTERRUPTIONHOWEVERTHESAMEMAYBECAUSED,INCLUDING
NEGLIGENCE.
9
Rev0‐01/2012
ContactInformation
TheISIS™IntelligentMultiplexSystemisaproductof
Infinitybox,LLC
1‐847‐232‐1991
[email protected]
www.isispower.com
10
Rev0‐01/2012