SR-SD-A series Solar Intelligent Charging Controller Operation instruction manual . Main features
Transcription
SR-SD-A series Solar Intelligent Charging Controller Operation instruction manual . Main features
SR-SD-A series Solar Intelligent Charging Controller Operation instruction manual Ⅳ. Status indications LED lamp Ⅰ. Main features 1. 12V/24V identify automatically. 2. LED constant current source is internally installed and its efficiency can reach 96%. 3. Light control and timer control. With intelligent four phases PWM digital dimming, the capacity control is much more accurate and the performance of color temperature is perfected. 4. Smart power mode, automatically adjust the load power according to the battery energy for maximum service life. 5. Outstanding ripple current control and degree of linearity control utmost lessening the LED light decline and increase LED life span. 6. Ceramic capacitor design extends the service life. 7. IP 68 waterproof level and aluminum outer shell is able to effectively prevent various kinds of corrosion. 8. Adopt high-precision crystal oscillator which make the timing more precise. 9. External temperature sensor can realize high-precision temperature compensation. 10. Metal outer casing design. 11. TVS lightning protection 12. Varies system protection function. Indications Status Functions Long-term On There is voltage on battery panel Charging Long-term Off No voltage on battery panel indication Slow twinkling Be on charged Fast twinkling Overpressure of system Long-term On Storage battery works normally Storage Long-term Off Storage battery is not connected Battery Slow twinkling Storage battery is undervoltage Fast twinkling Storage battery is excessively discharged Long-term On Load is on. Working with power of 100% Load is on. Working with power of 75% Load Ⅱ. Installation and wiring 1. Installation of controller should be stable and dimensions are as follows: Overall dimension: 82×58×20(mm) Installation dimension: 43×75(mm) Installation hole diameter: 3.5(mm) Load is on. Working with power of 50% Load is on. Working with power of25% off The load is off Ⅴ. Introduction of mode and table of settings SR-SD-A series controller has two working modes. Table of settings is as follows: 1. Light control + time control (1.-4.): When there is no sunlight, the light intensity will fall to the starting point. The controller will affirm the starting signal after a delay of 10 minutes. Load will be opened as per set parameters to start working and will switch the power as per the set time. When there is sunlight, the light intensity will rise up to the starting point. The controller will close output after confirming closing signal in a delay of 10 minutes and the load will stop working. 2. Demo mode (6.): Under this mode the user can control the on and off of load by keys no matter day or night. The time for demo mode is 8 seconds. Without key press after 8 seconds, it will return to the normal working mode. Ⅵ. Smart power control 2. SR-SD-A series controller can work under 12V or 24V voltage. Please connect storage battery at first for use. Controller will automatically identify voltage of storage battery and start to work. If it is the 12V system, the nixie tube will show ‘12’. If it is the 24V system, the nixie tube will show ‘24’. 3. Please connect the storage battery first, and then connect the photoelectric cell and the load. Pay attention to the “+” and “–” in case of reverse connection. 4. The anti-reverse connection is available. Even the photocell and battery connected wrongly, the controller will not be damaged. Wiring diagram is as below: When running the “smart power” mode, now the controller will enter to the smart power control mode. Led load power will automatically adjust the load power according to the battery energy. It still valid for the presetting the working time and load power. The system will choose the smaller one as the load output power after compare with the smart power and customize power. For example, when battery energy is 50%, smart power mode calculate the load power is 30%,if now customize load power is 100%,the controller will run in 30% but not 100%;If customize load power is 20%,the controller will run in 20%. LED1 LED 2 Mode parameter Display 1. 2. 3. 4. Working with 100% power Working with 75% power Working with 50% power Working with 25% power Display 0 – 4. 0 – 4. 0 – 4. 0 – 4. 5. Smart power open and close 0–1 6. Demo mode 0–4 Working for 0-14 hours with 100% power Working for 0-14 hours with 75% power Working for 0-14 hours with 50% power Working for 0-14 hours with 25% power 0 Smart power off 1 Smart power on 0 load is off 1 load works with 100% power 2 load works with 75% power 3 load works with 50% power 4 load works with 25% power Warm Tip: All controllers are light control priorities. Ⅶ. Methods for setting Ⅲ. Connection of LED 1. The SR-SD-A Controller is internally installed with constant current source. The max output voltage is 70V. The max amount of LED lights can be connected is 20pcs. 2. The SR-SD controller can automatically identify voltage of 12V and 24V. While connect with LED load, please ensure the number of LED lights in series is appropriate. The following data is we recommended. 12V The Min No.(n) Of LED lights In series n ≥ 5 24V n ≥ 10 System voltage Output voltage Output power VO ≥ 16V PLED ≤ 30W VO≥ 32V PLED ≤ 70W 3. Please connect LED light first and then open the load. Warning: if the number of LED in series is not appropriate, the controller or the LED load will be damaged. 1. Modes and parameter scan There are two nixie tubes installed on the controller. The first one shows the modes and the second shows the parameter under the mode. When working normally, press the button, mode and the parameter will be showed on. Then the mode value will change by each time you press, and the second tube will show the parameter under this mode. Mode and the parameter setting list can refer to the above list. 2. Adjustment of parameter. According to the operational approach of ” Mode and browse parameter”, press the button to set the mode, after setting the mode, press the button for more than 3s until the second tube flash .Then press the button to change the number showed on the second tube to set the parameter which you need. Stop press until the second tube stop flash or press the button more than 3s to finish setting. Setting more parameters, please repeat this step. 3. Smart power open and close According to “Smart power open and close” progress, setting the first tube show 5.(Five point),long press the key more than 3 seconds until the second tube flash then relax the key. Now the number showed on the second tube will change according to each short press. At the same time,smart power will be running according to your setting. 4. Demo mode. According to the step of ” Mode and browse parameter”, press the button until the first tube show “5.”, then press more than 3s till the second tube begin flash, release the button to set the parameter. Each press the second tube number will change, meanwhile the load power will change by the “Mode introduction and setting”. After the end of demo, stop press until the light stop flash then return to the working mode. Ⅷ. Instructions for parameters System voltage Output current No-load loss Solar input voltage The Max. charging current Overvoltage protection Equal charging voltage Ascending charging voltage Float charging voltage Return voltage during charging Return voltage for 12V/24V Auto 330mA – 2310mA 5mA/12V;7mA/24V < 55V 8A 17.0V; ×2/24V 14.6V; ×2/24V(25℃), duration:1h 14.4V; ×2/24V(25℃), duration:2h 13.8V; ×2/24V (25℃) 13.2V; ×2/24V (25℃) 12.5V; ×2/24V over-discharging Over-discharging voltage Temperature compensation Light-control voltage Efficiency of constant current Current accuracy Light-control judgment time The Max. output voltage Working temperature Protection level Weight Dimensions 11.1V; ×2/24V -4.0mv/℃/2V; Light-control open 5V; light-control close 6V 90% - 96% +/-2% 10min <70V -40℃ to +70℃; IP68 160g 82×58×20(mm)(L×W×H) Ⅸ. Problems and solutions Phenomena There is sunlight but indicator lamp of battery panel is not on. Indicator lamp for charging of battery panel twinkles fast Indicator lamp of battery panel is off; voltage of battery is normal and there is no output Indicator lamp of battery is not on Indicator lamp of storage battery twinkles fast and there is output Indicator lamp of load twinkles slowly and there is no output Indicator lamp of load twinkles fast and there is no output Indicator lamp of load is on permanently and there is no output Other phenomena Problems and solutions Please check the wiring of photocell and the contact. Overvoltage of the system; please check whether voltage of the storage batter is too high. Wait for 10 minutes and the load will open automatically. Power supply to storage battery fails. Please check the connection of storage battery. Storage battery is over discharged. Charge the battery fully. Power of load exceeds rated power. Press the key for long one time after reducing the use of electric equipments. Load is under short circuit. After removing fault, press the key once for a long time or wait until the next day. Please check whether connections of electric equipments are correct and reliable. Check the reliability of wiring and the automatic identification of 12V/24V system. The above information is subject to change without prior notice.