DVR Specifications Reference Manual MASvideo Rev D

Transcription

DVR Specifications Reference Manual MASvideo Rev D
MASvideo
DVR Specifications
Reference Manual
Rev D
Copyright
Copyright © 2014, UTC Fire & Security. All rights reserved.
This document may not be copied in whole or in part or otherwise reproduced without prior
written consent from UTC Fire & Security except where specifically permitted under US and
international copyright law.
Document revision: Rev D July 2014.
Disclaimer
The information in this document is subject to change without notice. UTC Fire & Security
assumes no responsibility for inaccuracies or omissions and specifically disclaims any
liabilities, losses, or risks, personal or otherwise, incurred as a consequence, directly or
indirectly, of the use or application of any of the contents of this document. For the latest
documentation, contact your local supplier or visit us online at www.utcfireandsecurity.com.
This publication may contain examples of screen captures and reports used in daily
operations. Examples may include fictitious names of individuals and companies. Any
similarity to names and addresses of actual businesses or persons is entirely coincidental.
Trademarks and patents
MASterMind Monitoring and MASterMind Business products and logos are registered
trademarks of UTC Fire & Security.
Other trade names used in this document may be trademarks or registered trademarks of
the manufacturers or vendors of the respective products.
Intended use
Use this product only for the purpose it was designed for; refer to the data sheet and user
documentation. For the latest product information, contact your local supplier or visit us
online at www.utcfireandsecurity.com.
iii
Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Conventions used in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety terms and symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
MASvideo (3.x and 4.x) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Accutrack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
BOSCH (Divar 2, XF, Divar 700, Dibos, VIP X1600 XF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Digia II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Interlogix (HAL supported UTC devices) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Ionit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
MarchNetworks5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
MiraSys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Pelco DX8000/DX8100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Scati . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SerVision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
StreamingMedia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Verint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
MASvideoN (2.x) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Accutrack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Digia II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Intellex 4.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Ionit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Pelco DX8000/DX8100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
MiraSys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Scati . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SerVision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
SymSuite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Verint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
VisioWave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
MASvideo Classic (1.x) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
BOS (Bosch Divar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
DM2 (Dedicated Micros Sprite) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
DMI (Dedicated Micros) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
GEO (Geo Vision) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
INT (Intellex). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
ITG (Integral) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Kalatel (DVMRe) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
LAN (Lanex) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
MAR (March Networks) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
PEL (Pelco) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
iv
MASvideo
DVR Specifications Reference Manual
RAP (Rapid Eye) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Contacting technical support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
MASvideo
DVR Specifications Reference Manual
Preface
This is the MASvideo DVR Specifications Reference Manual. This document details the specifications for
specific digital video recorders (DVRs) compatible with all MASvideo versions.
There is also information describing how to contact technical support if you have questions or concerns.
To use this document effectively, you should have the following minimum qualifications:
•
•
a basic knowledge of MASterMind Monitoring; and
a basic knowledge of video integration.
The most current versions of this and related documentation may be found on MAStech.
Conventions used in this document
The following conventions are used in this document:
Bold
Menu items and buttons.
Italic
Emphasis of an instruction or point; special terms.
File names, path names, windows, panes, tabs, fields, variables, and other GUI elements.
Titles of books and various documents.
Blue italic
(Electronic version.) Hyperlinks to cross-references, related topics, and URL addresses.
Monospace
Text that displays on the computer screen.
Programming or coding sequences.
Safety terms and symbols
These terms may appear in this manual:
CAUTION: Cautions identify important conditions or practices that may have serious implications that affect how the
software functions.
1
2
MASvideo
DVR Specifications Reference Manual
Introduction
This document provides the specifications for specific digital video recorders (DVRs) compatible with the
following MASvideo versions:
•
•
•
•
MASvideo (versions 3.x and 4.x)
MASvideo API (version 3.x and 4.x)
MASvideoN (versions 2.x)
MASvideo Classic (versions 1.x)
MASvideo (3.x and 4.x)
This section lists all MASvideo DVR specifications entered in the Site Options window for MASvideo by
DVR name. For more information, see Setting up video integration on page 3 of the MASvideo Reference
Manual.
MASterMind supports integration of UTC DVRs and continuously updates the plug-in, which provides this
support (see Interlogix (HAL supported UTC devices) on page 4). New hardware from other vendors may
require updated SDKs.
Accutrack
SDK Rev: 1.0.2952.17944
Supported operating sytems: Windows XP x86
Table 1. Accutrack site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
1024
MAS Video Type
ACCEMC
MAS Video Connect Option
MAS Video Password
1111 (default)
MAS Video Username
admin (default)
MASvideo
DVR Specifications Reference Manual
BOSCH (Divar 2, XF, Divar 700, Dibos, VIP X1600 XF)
MAS no longer supports the latest hardware and SDK of this vendor. Contact the vendor to get the new plugins and support.
SDK Rev: 4.43.04.03
Supported operating sytems: Windows XP/Vista/7 x86/x64
Table 2. BOSCH (Divar 2, Divar XF, Dibos, VIP X1600 XF) site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
0
MAS Video Type
BOSCH
MAS Video Connect
Option
Bosch Divar 2: GCA.Divar2.DeviceProxy
Bosh XF: GCA.DivarXF.DeviceProxy
Bosch 700: DCA.DivarXF.DeviceProxy
Bosch Dibos: GCA.DivarDibos.DeviceProxy
Bosh VIP X1600 XF: GCA.DivarVIP.DeviceProxy
MAS Video Password
DVR password, if required.
MAS Video Username
DVR username, if required
Entering 0,1,1 in the MASvideo Connect Option field sets the audio channels to 1, 1 (output, input).
The MASvideo Connect Option for Bosch devices is not mandatory but this option speeds up the connection
process and success rate. We recommend you leave this field blank if you do not know the exact device type.
Setting the video port to 0 lets the SDK and DVR negotiate usage of available ports.
In case the video stream freezes after starting the playback, disable SmoothReverse by setting the
disableSmoothReverse option to true in the MASvideoBoschPlugin.xml file. This also disables frame
forward/reverse and smooth reverse playback.
This integration requires the Bosch SDK to be installed.
Digia II
SDK Rev: 1.0.0.80
Supported operating sytems: Windows XP/Vista/7 x86/x64
Table 3. Digia II site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
1600 (default)
MAS Video Type
DIGIA
3
4
MASvideo
DVR Specifications Reference Manual
Table 3. Digia II site or system
Option
Option Values
MAS Video Connect Option
11111111 (8 ones) is the default or 33333333
MAS Video Password
4444 (default)
MAS Video Username
admin (default)
Interlogix (HAL supported UTC devices)
SDK Rev: 5.0.200.29 SP2
Supports all UTC DVRs.
Supported operating systems: Windows XP/Vista/7x86/x64
Legacy types
DVMRE
DVSE
DVMRE CS CD
DSR
DVMRE EZT
STORESAFE
DVMRE CT
Sym types:
SYMDEC1
SYMDEC16
SYMDEC4
SYMSAFE
TruVision types:
DVSRXU
TVR40
TVR10
TVR41
TVR11
TVR42
TVR12
TVR60
TVR20
GOVISION
TVR30
GOVISION 2.0
TVR31
VeDVR
NVRs:
TVN10
TVN40
TVN20
TVN50
TVN21
SVR
MASvideo
DVR Specifications Reference Manual
Streaming protocols:
TCP
ReverseTCP
UDP
ReverseTCPIframe
RTP
WaveletWaveJet
RTSP
TCPIFrame
HTTP
Table 4. HAL site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
MAS Video Type
HAL
MAS Video Connect Option
DVRtype or DVRtype^StreamingProtocol for Sym devices
MAS Video Password
DVR password, if required
MAS Video Username
DVR username, if required
This integration requires the HAL SDK to be installed in the plug-in installation folder.
Firmware version listing:
Recording device
Supported firmware
Network recorders
TruVision NVR50 (TVN50)
1.0m and above
TruVision NVR40 (TVN40)
4.3.0 and above
TruVision NVR21 (TVN21)
1.0k and above
TruVision NVR20 (TVN20)
2.0h and above
TruVision NVR10 (TVN10)
1.0.i and above
Analog and hybrid recorders
TruVision DVR60 (TVR60)
4.5a and above
TruVision DVR42 (TVR42)
1.0h and above
TruVision DVR41 (TVR41)
v2.0.e build 130228 and above
TruVision DVR40 (TVR40)
v3.2 and bove
TruVision DVR31 (TVR31)
v8000 and above
TruVision DVR30 (TVR30)
031j-028B-0676-8000 and above
TruVision DVR12-C (TVR12c)
1.0.g and above
TruVision DVR12 (TVR12)
1.0.g and above
5
6
MASvideo
DVR Specifications Reference Manual
Recording device
Supported firmware
TruVision DVR11-C (TVR11c)
2.1a and above
TruVision DVR11 (TVR11)
2.1 and above
TruVision DVR10 (TVR10)
v2.7 and above
TruVision SVR
7.0.816.7 and above
VeDVR
2.1 and above
SymDec 16 plus 4
1.46r, 1.47k, 1.51e, 1.52b, 1.53, and 1.60c
SymDec 4
1.47e and 1.48a
SymDec 1
1.47e and 1.48a
SymSafe Pro Series
1.27b, 1.28i, 1.30b, 1.31.b, 1.32, and 1.40c
SymSafe Basic Series
1.27b, 1.28i, 1.30b, 1.31.b, and 1.32
DVSRxU
v2.3 build 091110 (v2.31s)
DVMRE CT (Triplex) Series
5.68a, 5.69, 5.71, and 5.72
DVMRE CT II Series
6.28a, 6.29, 6.31, and 6.32
DVMRE PRO Series
5.68a, 5.69, and 5.71
DVMRE ezT Series
5.68a, 5.69, and 5.71
DVMRE CS Series
5.21
DVMRE CD Series
3.24
StoreSafe Series
5.68a, 5.69, 5.71 and 5.72
StoreSafe Pro II Series
6.28a, 6.29, 6.31 and 6.32
StoreSafe Advanced Series
6.28a, 6.29, 6.31 and 6.32
DSR
2.23d and 2.24a
DVSE Series
1.20g, 1.41w and 3.04
Compatible firmware is available at:
http://www.interlogix.com/video/
http://www.utcfssecurityproductspages.eu/videoupgrades
http://utcfssecurityproducts.com/CustomerSupport/Pages/VideoSurveillance.aspx
MASvideo
DVR Specifications Reference Manual
Ionit
SDK Rev: 1.3
Supported operating sytems: Windows XP x86
Table 5. Ionit site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
40001 (default)
MAS Video Type
IONIT
MAS Video Connect Option
MAS Video Password
DVR password, if required
MAS Video Username
DVR username, if required
MarchNetworks5
SDK Rev: 5.5.2.2200
Supported operating sytems: Windows XP/Vista/7 x86/x64
Table 6. MarchNetworks5 site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
MAS Video Type
MAR5
MAS Video Connect Option ESM server address (Enterprise Service Manager), if required
MAS Video Password
DVR password, if required
MAS Video Username
DVR username, if required
When setting up IP cameras in MASterMind Monitoring, enter the camera numbers in 1000s. For example,
enter 1006 instead of the analog camera number 6.
This integration requires the MarchNetworks5 SDK to be installed.
7
8
MASvideo
DVR Specifications Reference Manual
MiraSys
SDK Rev: MirasysSDK2.1.1
Supported operating sytems: Windows XP x86
Table 7. MiraSys site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
5001 (default)
MAS Video Type
MIRSYS
MAS Video Connect Option
MAS Video Password
MIRADVR32 (default)
MAS Video Username
admin/0803 (default)
Pelco DX8000/DX8100
MAS no longer supports the latest hardware and SDK of this vendor. Contact the vendor to get new plug-ins
and support.
SDK Rev: Version 3.2 with Service Pack 3
Supported operating sytems: Windows XP/Vista/7 x86/x64
Table 8. Pelco DX8000/DX8100 site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
9002 (default)
MAS Video Type
PELCO
MAS Video Connect Option
MAS Video Password
DVR password, if required
MAS Video Username
DVR username, if required
Scati
SDK Rev: 3.3.3/1.3.4
Supported operating sytems: Windows XP x86
Table 9. Scati site or system
Option
MAS Video IP Address
Option Values
MASvideo
DVR Specifications Reference Manual
Table 9. Scati site or system
Option
Option Values
MAS Video Port
8000 (default)
MAS Video Type
SCATI
MAS Video Connect Option Numbers of PTZ camera list, if needed, dash (-) separated list (1-2-3)
MAS Video Password
DVR password, if required
MAS Video Username
DVR username, if required
SerVision
SDK Rev: Version 1.5.4.40
Supported operating sytems: Windows XP/Vista/7 x86/x64
Table 10. SerVision site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
9980
MAS Video Type
SER
MAS Video Connect Option
MAS Video Password
DVR password, if required
MAS Video Username
DVR username, if required
StreamingMedia
SDK Rev: 2.1.1
Supported operating sytems: Windows XP/Vista/7 x86/x64
Table 11. StreamingMedia site or system
Option
Option Values
MAS Video IP Address
Address of device stream (can be video or audio-video stream; do not provide protocol
here)
MAS Video Port
Not used (by default 554, can be specified in Address connection option in accordance with
RTSP source URL Syntax: ip_address[:rtsp_port]/server_URL)
MAS Video Type
STRMED
MAS Video Connect Option Protocol^Camera description (e.g.: RTSP^Lobby camera)
MAS Video Password
Device user password
MAS Video Username
Device user name
9
10
MASvideo
DVR Specifications Reference Manual
Verint
SDK Rev: 4.0.0.18029
Supported operating sytems: Windows XP/Vista/7 x86/x64
Table 12. Verint site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
1024 (default)
MAS Video Type
VERINT
MAS Video Connect Option n/a
MAS Video Password
DVR password, if required
MAS Video Username
DVR username, if required
MASvideoN (2.x)
This sections lists all MASvideoN DVR specifications entered in the Site Options window for MASvideo by
DVR name. For more information, see Setting up video integration on page 3 of the MASvideo Reference
Manual.
Note: MASvideoN integrations are based on older SDKs. These integrations have not been tested on Windows versions
newer than Windows XP and may not work with newer equipment from respective vendors. To operate the latest UTC
DVRs, use MASvideo 3.x or 4.x instead.
Accutrack
SDK Rev: AccEMCControl
Table 13. Accutrack site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
1024
MAS Video Type
ACCEMC
MAS Video Connect Option
MAS Video Password
1111 (default)
MAS Video Username
admin (default)
MASvideo
DVR Specifications Reference Manual
Digia II
SDK Rev: Digia 2 SDK for Digia 204/209/216
Table 14. Digia II site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
1600 (default)
MAS Video Type
DIGIA
MAS Video Connect Option
11111111 (8 ones) is the default or 33333333
MAS Video Password
4444 (default)
MAS Video Username
admin (default)
2-way audio
Supports 2-way audio
Intellex 4.1
SDK Rev: Rev 4.1
Table 15. Intellex 4.1 site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
5000 (default)
MAS Video Type
INTELX
MAS Video Connect Option
5001 (default playback port)
MAS Video Password
Always leave this blank
MAS Video Username
DVR username, if required
Ionit
SDK Rev: 1.3
Table 16. Ionit site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
40001 (default)
MAS Video Type
IONIT
MAS Video Connect Option
MAS Video Password
DVR password, if required
11
12
MASvideo
DVR Specifications Reference Manual
Table 16. Ionit site or system
Option
Option Values
MAS Video Username
DVR username, if required
Pelco DX8000/DX8100
SDK Rev: Version 3.2 with Service Pack 3
Table 17. Pelco DX8000/DX8100 site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
9002 (default)
MAS Video Type
PELCO
MAS Video Connect Option
MAS Video Password
DVR password, if required
MAS Video Username
DVR username, if required
MiraSys
SDK Rev: MirasysSDK2.1.1
Table 18. MiraSys site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
5001
MAS Video Type
MIRSYS
MAS Video Connect Option
MAS Video Password
MIRADVR32 (default)
MAS Video Username
admin/0803 (default)
Scati
SDK Rev: RealTimeX.ocx
Table 19. Scati site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
8000 (default)
MASvideo
DVR Specifications Reference Manual
Table 19. Scati site or system
Option
Option Values
MAS Video Type
SCATI
MAS Video Connect Option Numbers of PTZ camera list, if needed, dash (-) separated list (1-2-3)
MAS Video Password
DVR password, if required
MAS Video Username
DVR username, if required
SerVision
SDK Rev: Version 1.5.4.40
Table 20. SerVision site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
9980
MAS Video Type
SER
MAS Video Connect Option
MAS Video Password
DVR password, if required
MAS Video Username
DVR password, if required
SymSuite
SDK Rev: SymSDK 1.8 (R7)
Table 21. SymDec 16 site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
1024
MAS Video Type
SYMSTE
MAS Video Connect Option SYMDEC16 (uses SYMDEC16-UDP)
SYMDEC16-UDP
SYMDEC16-REVERSETCP
SYMDEC16-MULTICAST
SYMDEC16-TCPIFRAME
SYMDEC16 -REVERSETCPIFRAME
SYMSAFE (SYMSAFE-UDP)
SYMSAFE-UDP
SYMSAFE-REVERSETCP
SYMSAFE-MULTICAST
SYMSAFE-TCPIFRAME
SYMSAFE-REVERSETCPIFRAME
13
14
MASvideo
DVR Specifications Reference Manual
Table 21. SymDec 16 site or system
Option
Option Values
MAS Video Password
1111 (default)
MAS Video Username
admin (default)
Streaming types for SymSuite
UDP. High bandwidth mode and uses UDP stream. This requires you to pass UDP ports to SDK (otherwise the
SDK internally considers the ports ranging from 8110) and for the system administrator to open ports on the
PC’s side.
Multicast stream. Supports multicast stream. This mode requires you to pass the destination multicast
address.
TCPIFRAME. Low bandwidth mode and uses TCP stream. This mode is deprecated.
REVERSETCP. High bandwidth mode and uses TCP stream. This mode is only applicable to SymDec16 and
SymSafe models.
REVERSETCPIFRAME. Low bandwidth mode and requests i-frames.
Verint
SDK Rev: 4.0.0.18029
Table 22. Verint site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
1024 (default)
MAS Video Type
VERINT
MAS Video Connect Option n/a
MAS Video Password
DVR password, if required
MAS Video Username
DVR username, if required
VisioWave
SDK Rev: 4.2
Table 23. VisioWave site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
5000
MAS Video Type
Visio
MASvideo
DVR Specifications Reference Manual
Table 23. VisioWave site or system
Option
Option Values
MAS Video Connect Option
MAS Video Password
MAS Video Username
In addition, VisioWave uses separate ports for each controllable subsystem. The MASterMind integration
requires these defaults. Table 24 describes how these ports must be configured.
Table 24. VisioWave configuration for MASvideoN integration
VisioWave Component
Required Ranges
Cameras
5001-5028 (Camera 1 is port 5001)
PTZ Controls
8001-8028 (Camera 1 PTZ is port 8001)
Audio Output
7501-7528 (Controlled by the Audio Out Channel on the site, Channel 1 is port 7501)
Audio Input
5501-5528 (Controlled by the Audio In Channel on the site, Channel 1 is port 5501)
Relay Contacts
6501-6528 (Controlled by the Contact Number on the site, Contact is port 6501)
Digital Inputs
4444 (Event manager Port)
MASvideo Classic (1.x)
This sections lists all MASvideo Classic DVR specifications (also known as legacy MASvideo) entered in the
Site Options window for MASvideo by DVR name. For more information, see Setting up video integration on
page 3 of the MASvideo Reference Manual.
Note: MASvideoN integrations are based on older SDKs. These integrations have not been tested on Windows versions
newer than Windows XP and may not work with newer equipment from respective vendors. To operate the latest UTC
DVRs, use MASvideo 3.x or 4.x instead.
BOS (Bosch Divar)
SDK Rev: 2.01
Table 25. BOS (Bosch Divar) site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
0
MAS Video Type
BOS
MAS Video Connect
Option
N/A
MAS Video Password
DVR password, if required.
15
16
MASvideo
DVR Specifications Reference Manual
Table 25. BOS (Bosch Divar) site or system
Option
Option Values
MAS Video Username
Username demoe (default)
DM2 (Dedicated Micros Sprite)
SDK Rev: DM Version 0.9.0.382 of the DMCom3Java.ocx
Table 26. DM2 (Dedicated Micros Sprite) site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
0
MAS Video Type
DM2
MAS Video Connect
Option
N/A
MAS Video Password
DVR password, if required.
MAS Video Username
DVR username, if required.
DMI (Dedicated Micros)
SDK Rev: DM Version 0.9.0.382 of the DMCom3Java.ocx
Table 27. DM1 (Dedicated Micros) site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
0
MAS Video Type
DM1
MAS Video Connect
Option
DVIP
MAS Video Password
password (default)
MAS Video Username
user (default)
GEO (Geo Vision)
SDK Rev: 6.01
Table 28. GEO (Geo Vision) site or system
Option
MAS Video IP Address
Option Values
MASvideo
DVR Specifications Reference Manual
Table 28. GEO (Geo Vision) site or system
Option
Option Values
MAS Video Port
0
MAS Video Type
GEO
MAS Video Connect
Option
N/A
MAS Video Password
Install101 (default)
MAS Video Username
secure (default)
INT (Intellex)
SDK Rev: 3.01
Table 29. INT (Intellex) site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
5001
MAS Video Type
INT
MAS Video Connect
Option
5000
MAS Video Password
DVR password, if required.
MAS Video Username
DVR username, if required.
ITG (Integral)
SDK Rev: 1.03
Table 30. ITG (Integral) site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
18772
MAS Video Type
ITG
MAS Video Connect
Option
N/A
MAS Video Password
letmein (default)
MAS Video Username
user (default)
17
18
MASvideo
DVR Specifications Reference Manual
Kalatel (DVMRe)
Table 31. Kalatel (DVMRe) site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
1024
MAS Video Type
KAL
MAS Video Connect
Option
N/A
MAS Video Password
DVR password, if required.
MAS Video Username
DVR username, if required.
LAN (Lanex)
SDK Rev: 1.01 Build 8
Table 32. LAN (Lanex) site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
7114
MAS Video Type
LAN
MAS Video Connect
Option
N/A
MAS Video Password
DVR password, if required.
MAS Video Username
DVR username, if required.
MAR (March Networks)
SDK Rev: March R5
Table 33. MAR (March Networks) site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
0
MAS Video Type
MAR
MAS Video Connect
Option
N/A
MAS Video Password
DVR password, if required.
MASvideo
DVR Specifications Reference Manual
Table 33. MAR (March Networks) site or system
Option
Option Values
MAS Video Username
DVR username, if required.
2-way audio
Supports 2-way audio
PEL (Pelco)
SDK Rev: 2.01
Table 34. Pelco site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
9002
MAS Video Type
PEL
MAS Video Connect
Option
N/A
MAS Video Password
DVR password, if required.
MAS Video Username
DVR username, if required.
RAP (Rapid Eye)
SDK Rev: Honeywell RapidEye Multi-Media 7.0, Version 7.0.60.0 of the Jplayer.dll
Table 35. Rapid Eye site or system
Option
Option Values
MAS Video IP Address
MAS Video Port
0
MAS Video Type
RAP
MAS Video Connect
Option
N/A
MAS Video Password
DVR password, if required.
MAS Video Username
DVR username, if required.
19
20
MASvideo
DVR Specifications Reference Manual
Contacting technical support
You can reach MAS about MASterMind products at 2955 Red Hill Ave, Costa Mesa, CA 92626; phone
949.737.7800, or Internet at www.masmonitoring.com.
Support
For assistance with MASterMind Monitoring, MASterMind Business, or MASweb, you may contact our
helpdesks using any of the methods described in the table below.
Table 36. Support contact information
Description
Helpdesk
i-Support
e-service
MAS support personnel are
dedicated to providing timely
worldwide assistance in all
product areas. Our help desks
are available Monday through
Friday, excluding holidays,
between 06:00 and 17:00
Pacific Time.
MAS provides this Internet-based
service, where you can both
submit new inquires and monitor
the status of existing inquires. You
must obtain a username and
password to use i-Support by
emailing us at the address below.
MAS provides customers the
means to e-mail in a new issue
directly to the Support Desk. The
e-mail should include the product
name, details of the problem,
contact name, and phone number.
When the e-mail is received by our
system, it will then automatically
generate a support ticket. All MAS
Helpdesk Personnel review this
queue.
Toll-free: 800.225.9056 (US,
including Alaska and Hawaii;
Puerto Rico; Canada)
If you need to register for this
service, send your request to:
[email protected].
Send inquiries directly to the
helpdesk at:
[email protected]
Outside the toll-free area:
949.737.7800
After you register, access i-Support
via our website.
24/7 Code Red support is also
available using the phone
numbers listed below.
Contact Info
Note: Please have your customer number available before contacting the Helpdesk.
Sales
Want to know more about MASterMind products or have questions we can answer? Just contact our Sales
Department at 800.447.6721, or email us at [email protected].
MAStech
MAS provides customers the means for downloading software and documentation via MAStech, our accesscontrolled Internet site. If you need to register for this service, send your request to: [email protected].
Once registered, access MAStech via our web site: https://supportcentral.1utcfs.com/products/
sup_products.asp?prod_id=89413.
Training
MAS offers an extensive class catalog and custom classes designed to provide a complete understanding of
MASterMind products. For more information about our training, contact our Training Department by clicking
here or calling us at 949.737.7800.