3M Safety Products For Domestic Preparedness 3
Transcription
3M Safety Products For Domestic Preparedness 3
3M™ Safety Products For Domestic Preparedness Helping to keep response personnel prepared and safe for most emergencies 3Innovation Fast And Sure Response Is Necessary For All Local And National Emergencies An attack with chemical, biological or nuclear weapons is an ever-present threat. Because this threat exists, and because of the danger that it poses at the local, regional and national levels, the highest priority has been given to mitigating this threat. Basically, all units of law enforcement have been asked to prepare for the kinds of emergencies that they may be required to face. Preparation for such an event requires extensive training of all response personnel. This will involve gaining knowledge of different types of agents, learning which procedure is required for the specific contaminant and selecting the equipment that is appropriate in each case. Important Before using these respirators, you must determine the following: 1. If there is sufficient oxygen present. 2. The type of contaminant(s) for which the respirator is being selected. 3. The concentration level of that contaminant. 4. Whether the respirator can be properly fitted on the wearer’s face. All respirator instructions, warnings and use and time limitations must also be read and understood by the wearer before use. See page 9 in this brochure for WARNINGS and Product Use Limitations. First responders–those who are at the forefront of saving lives–need the best equipment available. That’s why 3M has developed a line of personal protective equipment that meets the needs of most emergencies. These products are described in detail in this brochure. 3M offers innovative solutions for personal safety. We want to put our resources to work in helping you to prepare. The first responders canister (FR-C2A1) in this brochure can only be sold to companies or individuals who are registered under the Controlled Goods Legislation. For more information on the registration process please contact the Public Works and Government Services Canada web site at www.pwgsc.gc.ca and look under the Index for Controlled Goods Registration Program. Or call the Information Services Officer at 1-866-333-2477. 3M™ Filtering Facepiece Particulate Respirators Product Features 8293 P100 particulate respirator. Minimum 99.97% filter efficiency. Features adjustable straps, 3M™ Cool Flow™ Exhalation Valve and face seal. Appropriate for use where HEPA was previously required. 8233 N100 particulate respirator. Minimum 99.97% filter efficiency. Features adjustable straps, Cool Flow exhalation valve and face seal. Appropriate for use where HEPA was previously required. Not for use in atmospheres containing oil aerosols. 8577 P95 particulate respirator. Minimum 95% filter efficiency. 3M recommended for relief against nuisance level organic vapor.* Features M-noseclip and Cool Flow exhalation valve. 8271 P95 particulate respirator. Minimum 95% filter efficiency. Features M-noseclip, Cool Flow exhalation valve, and face seal. 8511 N95 particulate respirator. Minimum 95% filter efficiency. Features M-noseclip and Cool Flow exhalation valve. Not for use in atmospheres containing oil aerosols. 8210 N95 particulate respirator. Minimum 95% filter efficiency. Not for use in atmospheres containing oil aerosols. 9210 N95 particulate respirator. Minimum 95% filter efficiency. Features unique 3-panel design and advanced electret media. Not for use in atmospheres containing oil aerosols. Folds flat for easy storage. 9211 N95 particulate respirator. Minimum 95% filter efficiency. Features unique 3-panel design, advanced electret media and Cool Flow exhalation valve. Not for use in atmospheres containing oil aerosols. Folds flat for easy storage. *Nuisance levels refer to concentrations below the OSHA permissible exposure limit. 3M™ Negative Pressure Respirators 3M™ 6000 Series Full Facepiece Respirators Offer The Flexibility Of Negative/Positive Pressure Operation • As a negative pressure system, the 6000 series full facepiece can be used with 3M™ Cartridges CP3N for tear agents and FR-64 for most military and industrial materials. • Can also be used with other industrial 3M™ Filters and Cartridges • Available in small, medium and large sizes • Comfortable, lightweight • Flexible and durable silicone face seal • Provides a wide field of vision • Easy to adjust head straps • Can be used in negative/positive pressure applications 3M™ 7800S Full Facepiece Respirators — The Standard By Which Other Respirators Are Judged • As a negative pressure system, the 7800S full facepiece can be used with 3M™ Cartridges CP3N for tear agents and FR-64 for most military and industrial materials • Can be used with other industrial 3M™ Filters and Cartridges • 6-point adjustable head strap provides secure, comfortable fit • Can be used in negative/positive pressure applications • Double-flange face seal for added comfort • Designed for versatility, comfort and long life • Available in small, medium and large sizes 3M™ Respiratory Services Quantitative Fit Testing Fit testing is done to: • Identify the size facepiece users can wear to protect themselves • Verify the ability of the user to properly don, position and adjust the straps of the respirator facepieces Qualitative Fit Testing Respiratory Protection Training Course Content: • Nature, extent and effects of respiratory hazards • Operation, limitation and capabilities • Inspection, donning, wearing and removal • Fit testing/user seal checking • Maintenance, cleaning and storage • Emergency situations involving use or malfunction 3M™ Positive Pressure Respirators 3M 3M™ 6000 Series RRPAS™ (Rapid Response Powered Air System)... When Fast Response Is Absolutely Necessary • This is a powered air purifying respirator (PAPR) system in which the components are stored in a unique carrying bag that transforms into a vest with the PAPR in place and ready for use with the 3M™ Canister FR-40 and Cartridge FR-57 • Provides exceptional comfort and mobility • Easy to don and doff • Hook and loop fasteners allow fast and easy adjustment to individual sizes • The power unit provides continuous flow of filtered air • Can be used with rechargeable nicad battery or disposable lithium battery • Approximate weight is 10 lbs. • Also available as belt-mounted PAPR. 3M™ Breathe Easy™ (BE) 10 Butyl Rubber Hood Systems Provide Exceptional Protection For Civilian Responders • The lightweight butyl rubber hood provides protection, excellent mobility and visibility • Butyl rubber meets MIL-C-51251A (EA) for resistance to chemical agents • Provides a continuous flow of filtered air • The belt-mounted power unit is lightweight and comfortable • Can be used with rechargeable nicad battery or disposable lithium battery • The hood can be worn with facial hair and glasses • No fit testing is required prior to wearing a hood • For use with the FR-57 cartridge • Approximate weight is 8 lbs. 3M™ Air-Mate™ SCBAG™ Self-Contained Breathing Apparatus (SCBA) Is Uniquely Innovative • Totally unique with all components stored in a carrying bag that converts into a vest with everything in place and ready to wear • Completely portable • Can be donned in seconds • The lightweight harness has shoulder and back padding for greater comfort • Continuous chest size adjustment up to 58" to fit most wearers • Hook-and-loop closures allow fast and easy donning • The vest distributes weight evenly for added comfort • Great for confined spaces and emergency use • Optional airline connection for extended time usage in IDLH atmospheres • Hoop-wrapped, 30-minute cylinder is positioned for ideal weight distribution and easy valve access • The full facepiece is based on 3M’s innovative technologies • Lightweight and comfortable to wear • Features a quarter-turn pressure-demand valve with first-breath activation • Facepiece available in small, medium and large Selection Chart for First Response Respirators 3M™ Product Product Description Appropriate for Level1 Suggested Applications2 SCBAG™ SCBA System Page 8 Vest mounted, 30 minute, pressure-demand SCBA B Emergency response in IDLH3 oxygen deficient and unknown environments Breathe Easy™ (BE) 10 Butyl Rubber Hood System Page7 Belt-mounted PAPR with loose fitting butyl rubber hood C Response in non-IDLH4 environments, medical evacuation, spill clean-up, decontamination, law enforcement 6000 Series Page 6 Vest-mounted/belt-mounted PAPR with tight-fitting full facepiece C Response in non-IDLH4 environments, medical evacuation, spill clean-up, decontamination, law enforcement 6000/7800S Full Facepieces Page 4 Negative-pressure, full facepiece air-purifying respirators C When properly fitted, use when concentrations are less than 50X PEL. Filtering Facepiece Particulate Respirators Page 3 Negative-pressure, filtering facepiece respirators C When properly fitted, use when concentrations are less than 10X PEL. 1 Level B requires the highest level of respiratory protection – a pressure-demand, full facepiece Self-Contained Breathing Apparatus (SCBA), or combination pressure-demand supplied air respirator with escape SCBA, approved by NIOSH. Level C allows that properly selected, air purifying respirators can be worn providing that the concentration(s) and type(s) of airborne substance(s) are known and the criteria for using air purifying respirators are met (atmosphere is NOT IDLH and NOT oxygen deficient). 2 Respirators must be properly selected for each concentration and type of airborne substance. 3 IDLH-Immediately Dangerous to Life or Health is an atmospheric concentration of any toxic, corrosive or asphyxiant substance that poses an immediate threat to life or would cause irreversible or delayed adverse health effects or would interfere with an individual’s ability to escape from a dangerous atmosphere. 4 Non-IDLH – one which is not IDLH, is not oxygen deficient and where the concentration(s) and type(s) of airborne substance(s) are known. 5 Systems not approved with a pass-through device. WARNING • Before using any of the respiratory products pictured in this brochure, the wearer must read and understand all warnings, use limitations and fitting instructions accompanying each product. Failure to do so may result in serious bodily injury, sickness or death. • Use of 3M™ Respirators by untrained or unqualified persons, or use not in accordance with the instructions, may adversely affect product performance and result in serious bodily injury, sickness or death. • Each respirator must be properly selected based on the contaminant and concentration levels to which the worker is exposed. • 3M respirators are to be used only by qualified persons properly trained in their use and maintenance, and only in accordance with their operating and maintenance manuals. Each person using these products must first read and understand the operator’s manual. Failure to do so may result in serious bodily injury, sickness or death. • The compressed air used with any SCBA, Escape SCBA or supplied air system shall meet at least the requirements for grade D breathing air per Compressed Gas Association Commodity Specification, CGA G-7.1-1989, in the United States, and Table 2 of the CSA Standard CAN3-Z180.1-M85, in Canada. The compressor shall be equipped with safety and standby devices per OSHA Standard 1910.134 or CSA Standard CAN3-Z180.1-M85. • Be sure breathing air couplings are incompatible with outlets for nonrespirable plant air or other gas systems to prevent servicing of airline respirators with nonrespirable air or oxygen. • The employer must also have established a satisfactory respirator program such as described in OSHA Standard 1910.134 or CSA Standard Z94.4-93. • Airborne exposure limits have not been established for biological hazards. Respirators can only reduce the exposure. They do not eliminate the risk of contracting disease or infection. Use Limitations 1. Failure to comply with all instructions and warnings on the use of these products and/or failure to wear the respirator during all times of exposure may reduce respirator effectiveness and result in serious bodily injury, sickness or death. 2. Never alter or modify this respirator. 3. Repair or replace respirator parts if they become damaged or worn. Use appropriate 3M parts only. 4. DO NOT use Air Purifying Respirators when concentrations of contaminants are unknown or immediately dangerous to life or health (IDLH). 5. Use of the equipment described in this catalog should be in accordance with applicable safety and health standards, respirator selection tables contained in such publications as ANSI Z88.2-1992, or pursuant to the recommendations of an industrial hygienist. 6. If you have any doubts about the applicability of the equipment to your job situation, it is recommended you consult an industrial hygienist or call 3M Occupational Health and Environmental Safety Division, Technical Service Department, 1-800-267-4414. Ordering Information 3M™ Product Number National Stock Numbers Product Description NIOSH Approval Number* Filtering Facepiece Particulate Respirators 8293 4240-01-475-8293 8293 P100 Particulate Respirator 8233 4240-01-452-8348 8233 N100 Particulate Respirator TC-84A-2561 TC-84A-1298 8577 4240-01-452-8331 8577 P95 Particulate Respirator with nuisance level organic vapor relief TC-84A-1166 8271 4240-01-247-5686 8271 P95 Particulate Respirator TC-84A-1166 8511 4240-01-247-2348 8511 N95 Particulate Respirator TC-84A-1299 8210 4240-01-429-2685 8210 N95 Particulate Respirator TC-84A-0007 9210 9210 N95 Particulate Respirator TC-84A-2669 9211 9211 N95 Particulate Respirator TC-84A-2668 Cartridges for 6000, 7800S Air Purifying, Negative Pressure Facepieces 450-02-11R06 4240-01-418-2634 CP3N Canister, 6000DIN, 7800S 60926 60926 Cartridge, 6000DIN TC-84A-0704 60926 Cartridge, 7800S TC-84A-0537 4240-01-455-7370 TC-14G-0251 FR-C2A1 FR-C2A1 Cartridge, FR-M40 TC-84A-3281 FR-64 FR-64 Cartridge, FR-M40, 6000DIN, 7800S Pending 6000 and 7800S Series Facepieces 7800SSm 4240-01-314-2780 7800S Full Facepiece – Silicone, (Small) See Cartridges 7800S M 4240-01-342-5239 7800S Full Facepiece – Silicone, (Medium) See Cartridges 7800S L 4240-01-301-3200 7800S Full Facepiece – Silicone, (Large) See Cartridges 6700DIN 4240-01-479-1593 6000 Full Facepiece, (Small) See Cartridges 6800DIN 4240-01-479-1598 6000 Full Facepiece, (Medium) See Cartridges 6900DIN 4240-01-479-1597 6000 Full Facepiece, (Large) See Cartridges Batteries and Chargers for Breathe Easy (BE) 10 and 6000 RRPAS 520-01-61SGL Battery Charger, “Smart Charger”, Single Unit for Breathe Easy Systems only 520-01-61FIV Battery Charger, “Smart Charger”, 5 Unit for Breathe Easy Systems only Component Component 520-01-15R01 Nicad Rechargeable Battery Pack for Breathe Easy Systems only Component 520-01-17R01 Nicad Rechargeable Battery Pack for Breathe Easy Systems only Component 520-04-57R01 Lithium Disposable Battery Pack for Breathe Easy Systems only Component Breathe Easy (BE) 10 and 6000 RRPAS Cartridge and Canister 453-03-02R06 4240-01-480-1387 FR-57 Cartridge TC-23C-2072 453-03-03R06 4240-01-480-1386 FR-40 Canister TC-14G-0261 FR-40L68 RRPAS Rapid Response Powered Air Purifying Respirator System, 6800DIN Lithium Battery and FR-40 Canister See Canister FR-57N68 RRPAS Rapid Response Powered Air Purifying Respirator System, 6800DIN Nicad Battery and FR-57 Cartridge See Cartridge FR-57L69 RRPAS Rapid Response Powered Air Purifying Respirator System, 6900DIN Lithium Battery and FR-57 Cartridge See Cartridge FR-57N69 RRPAS Rapid Response Powered Air Purifying Respirator System, 6900DIN Nicad Battery and FR-57 Cartridge FR-40N68 RRPAS Rapid Response Powered Air Purifying Respirator System, 6800DIN Nicad Battery and FR-40 Canister See Canister FR-40L69 RRPAS Rapid Response Powered Air Purifying Respirator System, 6900DIN Lithium Battery and FR-40 Canister See Canister FR-57L68 RRPAS Rapid Response Powered Air Purifying Respirator System, 6800DIN Lithium Battery and FR-57 Cartridge See Cartridge FR-40N69 RRPAS Rapid Response Powered Air Purifying Respirator System, 6900DIN Nicad Battery and FR-40 Canister 6000 RRPAS See Cartridge See Canister Breathe Easy (BE) 10 Butyl Rubber Hood Systems FR-57N10 Breathe Easy 10 with Butyl Rubber Hood, Nicad Battery and FR-57 Cartridge See Cartridges FR-57L10 Breathe Easy 10 with Butyl Rubber Hood, Lithium Battery and FR-57 Cartridge See Cartridges BA-4430-S SCBAG(small facepiece) TC-13F-454 BA-4530-S SCBAG w/Airline (small facepiece) TC-13F-454 BA-4430-M SCBAG (medium facepiece) TC-13F-454 Air-Mate SCBAG BA-4530-M SCBAG w/Airline (medium facepiece) TC-13F-454 BA-4430-L SCBAG (large facepiece) TC-13F-454 BA-4530-L SCBAG w/Airline (large facepiece) TC-13F-454 *NIOSH approval numbers apply to whole systems only. NIOSH approval numbers apply only to system and cartridge or filter listed. Systems used in configurations other than those listed may have separate NIOSH approval numbers; please see product insert. Technical Information: Cartridges /Canisters 3M™ Air-Purifying Cartridges and Canisters for Air Purifying Respirators for Responder Applications Air purifying respirators (APR) can be used when the contaminant and concentration are known and below IDLH limits and sufficient oxygen is present. The maximum use concentration (MUC) in which an APR can be utilized is the product of the assigned protection factor (APF) multiplied by the airborne exposure limit (such as the TLV®). This number however must be lower than the IDLH, otherwise the IDLH becomes the MUC. Respirator 3M System APF Negative Pressure, Full Facepiece APR Full Facepiece Respirator, 6000 Full Facepiece Respirator, 7800S Full Facepiece Respirator 501 PAPR with Hood, Helmet, or Tight-Fitting Full Facepiece Breathe Easy (BE) 10 Butyl Rubber Hood, BE 10 and 6000 RRPAS 1000 3M Air-Purifying Cartridge or Canister – NIOSH Approvals2 Negative Pressure Applications PAPR Applications NIOSH Approvals TLV3 Organic Vapors * Sulfur Dioxide 2 ppm 5 ppm STEL Hydrogen Chloride 5 ppm C Chlorine 0.5 ppm TWA, 1 ppm STEL Chlorine Dioxide 0.1 ppm TWA 0.3 ppm STEL Hydrogen Fluoride 3 ppm C Ammonia 25 ppm TWA, 35 ppm STEL Methylamine 5 ppm TWA 15 ppm STEL Formaldehyde 0.3 ppm C Hydrogen Sulfide 10 ppm TWA (escape)5 15 ppm STEL Phosphine 0.3 ppm 1 ppm STEL CN6 0.3 mg/m3 6 CS 0.39 mg/m3 P100 Particulates5 * High Efficiency (HE) * Particulate7 Negative Pressure Applications PAPR Applications Military Specification TLV3 Testing8 Diethyl NA Methylphosphonate (DMMP)9 Hydrogen Cyanide 4.7 ppm C Cyanogen Chloride 0.3 ppm C Chloropicrin 0.1 ppm TWA Phosgene 0.1 ppm TWA CN6 0.3 mg/m3TWA 6 CS 0.39 mg/m3 OASG limit value10 Sarin (GB) 0.0001 mg/m3 CP3N • 60926 • FR-C2A1 • FR-64 • FR-40 FR-57 • IDLH Limit4 * TWA 100 ppm • • • • • • • • • • • 100 ppm 30 ppm • • • • • • • • • • 10 ppm • • 30 ppm 500 ppm • • • • 100 ppm • • • 30 ppm 300 ppm • • • • • 200 ppm TWA 101 mg/m3 C 1.9 mg/m3 * * • • • • • • • • • • • • • • • • • • • • • • 3M Air-Purifying Cartridge or Canister – Common Military Agents2 • • • • IDLH Limit4 NA • • • • 50 ppm ND 4 ppm 2 ppm 101 mg/m3 C 1.9 mg/m3 OASG limit value10 > 0.2 mg/m3 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • TWA = time weighted average, C = Ceiling Limit, STEL = short term exposure limit, NA = not applicable, ND = not determined * Limits depend on specific contaminant. However, exposure limits have been set for particulates not otherwise classified (PNOC) and particulates not otherwise regulated (PNOR). 1 APF applies only when respirator has been quantitatively fit tested. If fit tested qualitatively, an APF of 10 applies. 2 Assumes that the criterion for using air-purifying respirators is met: the agent and concentration are known and are below maximum use concentrations and IDLH limits and sufficient oxygen is present. 3 TLV = threshold limit value from the American Conference of Governmental Industrial Hygienists. ACGIH Threshold Limit Values and Biological Exposure Indices, 2000. 4 IDLH = Immediately Dangerous to Life or Health limit. NIOSH Pocket Guide to Chemical Hazards. 1990. DHHS (NIOSH) Publication No. 90-117. 5 H2S escape only and P100 approvals are available for negative pressure, air purifying respirators only. 6 CN, CS approvals are available for tight fitting, air purifying respirators only. They are not available for respirators with loose-fitting headgear such as hoods or helmets. 7 High Efficiency (HE) particulate filter approval is available for PAPRs only. 8 3M Respirators are not NIOSH approved for these agents. There are no NIOSH approval schedules for DMMP, GB, hydrogen cyanide, cyanogen chloride, chloropicrin, and phosgene. See footnote 6 for explanation of CN and CS. 9 DMMP is a common surrogate test agent for the nerve agents. 10 TLV and IDLH Limit values have not been established for sarin. The values listed for sarin (GB) are the airborne exposure limit and the limit for which an SCBA is the only acceptable respiratory protection. The Office of the US Army Surgeon General (OASG) established these values. 3M™ Personal Protection Products 3M™ Sorbents And Spill Kits • For many first-response applications • Petroleum, maintenance and chemical sorbents fill many needs • Also available in unique folded sorbents; one product that is a pillow, pad, roll or boom in the same box. 3M™ Disposable Ear Plugs 1100 • Tapered design to conform to ear canal and provide added comfort • Smooth, dirt resistant surface for hygiene • Bright, orange color for visibility • Soft foam seals ear comfortably 3M™ Three Position Ear Muffs 1427 • 3-position adjustable head strap • Rotating headband allows easy adjustment for most secure fit • NRR: 27 dB • Use for applications up to 100 dBA TWA • For exposure to gun fire, 3M recommends dual protection (ear muffs and ear plugs worn together) 3M™ First Aid Kit 7730 • 3M™ Steri-Strip™ Skin Closures Also sold separately • 3M™ Coban™ Self-Adherent Wrap • 3M™ Cold & Hot Therapy • 3M™ Opticlude™ Orthoptic Products Eye Patch For more information contact: Technical Assistance 1-800-267-4414 3M O.H.E.S. Marketing 1-800-265-1840, ext. 6137 Internet www.3M.com/ca/occsafety E-mail [email protected] 3 Occupational Health and Environmental Safety 3M Canada Post Office Box 5757 London, Ontario N6A 4T1 “3M”, “Breathe Easy”, “RRPAS”, “Air-Mate” and “SCBAG” are trademarks of 3M. Used under licence in Canada. TLV is a registered trademark of American Conference of Governmental Industrial Hygienists. Printed in Canada © 3M 2001 0110-SK-14589-b-E