Quick Start Guide Resources & Next Steps A GATEWAY

Transcription

Quick Start Guide Resources & Next Steps A GATEWAY
Resources & Next Steps
Quick Start Guide
• Connect via RShell for advanced reader settings.
XARRAY®
• Develop controlling application using Octane SDK.
GATEWAY
XARRAY ACCESSORIES
Description
Part Number
Universal Power Supply
IPJ-A2002-000
AC Power Cord (region-specific)
IPJ-A2051-xxx
Console Cable
IPJ-A4000-000
This guide provides simple steps to quickly start using your new
xArray® gateway. For a full description of connection methods, reader
configuration and system setup options, please consult the xArray
Installation and Operations Manual.
Find Helpful Information:
Box Contents
Sales: http://www.impinj.com/contact-us/
Support: http://support.impinj.com
General: http://www.impinj.com
Certified Partners: http://www.impinj.com/where-to-buy/
• 1 xArray Gateway
• 1 Quick Start Guide
• May include tag samples from Impinj
inlay partners* featuring Monza® chips
Optional accessories:
• Power supply**
• Power cord
• Console cable
Notices: Copyright © 2014, Impinj, Inc. All rights reserved.
Impinj gives no representation or warranty, express or implied, for accuracy or reliability of information in this document. Impinj reserves the
right to change its products and services and this information at any time without notice.
EXCEPT AS PROVIDED IN IMPINJ’S TERMS AND CONDITIONS OF SALE (OR AS OTHERWISE AGREED IN A VALID WRITTEN INDIVIDUAL
AGREEMENT WITH IMPINJ), IMPINJ ASSUMES NO LIABILITY WHATSOEVER AND IMPINJ DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY,
RELATED TO SALE AND/OR USE OF IMPINJ PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR
PURPOSE, MERCHANTABILITY, OR INFRINGEMENT.
NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY PATENT, COPYRIGHT, MASK WORK RIGHT, OR OTHER
INTELLECTUAL PROPERTY RIGHT IS GRANTED BY THIS DOCUMENT.
Impinj assumes no liability for applications assistance or customer product design. Customers should provide adequate design and operating
safeguards to minimize risks.
Impinj products are not designed, warranted or authorized for use in any product or application where a malfunction may reasonably be
expected to cause personal injury or death or property or environmental damage (“hazardous uses”) or for use in automotive environments.
Customers must indemnify Impinj against any damages arising out of the use of Impinj products in any hazardous or automotive uses.
Impinj, xArray, Indy, Monza, Speedway, and STP are trademarks or registered trademarks of Impinj, Inc. All other product or service names are
trademarks of their respective companies.
The xArray gateway is covered by one or more of the following U.S. patents. Other patents pending. 7026935, 7030786, 7049964, 7107022,
7187290, 7245213, 7246751, 7283037, 7304579, 7382257, 7391329, 7405660, 7408466, 7417548, 7419096, 7432814, 7436308, 7501953, 7510117,
7589618, 7592897, 7633376, 7696882, 7830262, 7830322, 7920046, 7973643, 7973645, 7982611, 8063740, 8072327, 8077013, 8082556,
8115590, 8120494, 8174367, 8154385, 8237562, 8260241, 8325014, 8350665, 8390425, 8390430, 8391785, 8427315, 8446258, 8451119,
8471708, 8570157, 8698629, 8810376, 8830065, D570337, D574369, D574370
Before getting started, download and install the following on your PC:
http://support.impinj.com
• xArray test software utility
• xArray Installation and Operations Manual
• Octane Firmware version 5.2 or later (provided by Impinj Certified Partner)
http://support.apple.com/kb/dl999
• Bonjour Print Services
*Samples are provided courtesy of our inlay partner(s), and may not be available with every reader. Samples are provided for use in reader
setup and to experience unique Monza features, and are not intended to represent all the Monza-based inlay varieties available from Impinj
inlay partners. We encourage you to ask your provider about RFID labels or inlays featuring Monza tag chips.
Impinj, Inc. 701 N. 34th Street, Suite 300 Seattle, WA 98103
www.impinj.com Tel: 206.517.5300 Fax: 206.517.5262
4
Document Version 1.0 Part Number: 51342-407
© 2014, Impinj, Inc.
**This product should be used with a Listed/Certified power supply, marked LPS or Class 2, with 24Vdc output, rated minimum 2.5A.
(Ce produit est conçu pour être alimenté avec une alimentation Mis / certifiés, marqué LPS ou de classe 2, avec sortie 24V, 2,5 A nominal minimum)
Document Version 1.0 Part Number: 51342-407
© 2014, Impinj, Inc.
Reading Tags with the xArray Gateway
1) Remove the mounting plate
a) Push the mounting clip away from the xArray
Gateway and the mounting plate will release.
b) Once the mounting plate is released, it can be
slid out and removed during setup.
2) Connect using PoE
d) If desired, test your connection by pinging hostname.local. The
hostname follows the format xarray-XX-XX-XX where XX-XX-XX is the
last three couplets of the gateway ’s MAC address (printed on reader label).
(e.g., ping xarray-10-28-42.local)
NOTE: If your network does not support DHCP, use a Cisco-style console cable (RJ-45 to DB9)
for a direct RS-232 serial connection to the gateway. The RShell command line interface
can configure a static IP address (consult the xArray Installation and Operations Manual). Once
completed, you can connect to the product over Ethernet.
3) Set region (optional) and check firmware version
a) With the mounting plate removed, the unit’s connectors are exposed.
a) Connect to the WebUI using a web browser
http://<xArray name or IP address>.
b) Log in using default credentials:
user name: root
password: impinj
c) Select your region from the drop down list. You, the user, are responsible to
ensure operation with the correct RF settings and are solely responsible for
any fines and other damages due to incorrect or non-compliant country/ region
settings. NOTE: GX1 and GX2 xArrays have no region pre-configured and will not
transmit RFID signals until region is selected.
b) Connect to the xArray gateway using a IEEE802.3af (Power over Ethernet)
compliant power network switch or power injector.
d) Click the REBOOT button. When changing operating region, the change does
not take effect until the next reboot.
e) Note the “Software Version” shown on the WebUI. Ask your Impinj Certified
Partner for the latest released version and upgrade if necessary using the
“Reader Upgrade” utility in the WebUI. The firmware for xArray is named Octane.
4) Read tags with Impinj test software utility
power + data
data
If PoE is not available, connect to the xArray gateway using a Listed/Certified
power supply, marked LPS or Class 2, with 24Vdc output, rated minimum
2.5A.
c) If connecting to a network with a DHCP server, ensure your PC has Bonjour
Print Services enabled (install if necessary) and test your connection as
described in Step 2d.
a) Install (if necessary) and open the test software utility application.
b) Click “Configure Settings” and add information to connect to your xArray.
c) Place tags in the field of view. Click the Start button and watch tag information
as it is read and displayed.
d) Some basic settings can be changed in the test software utility, review Impinj
documents to learn about each setting.
If connecting directly to your computer, use Bonjour, or if the address is
not found, access the xArray at IP address 169.254.1.1. Using a web browser,
connect to http://169.254.1.1. Connect to RShell using ssh 169.254.1.1.
2
Document Version 1.0
Part Number: 51342-407
© 2014, Impinj, Inc.
3