cv 3-200 e - Europower Components Ltd
Transcription
cv 3-200 e - Europower Components Ltd
Voltage Transducer CV 3-200 VPN = 140 V For the electronic measurement of voltages: DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). 0630 Electrical data VPN VPM VS KN RL CL VC IC Primary nominal voltage rms Primary voltage, measuring range (Analog) secondary voltage @ VP maxi Conversion ratio Load resistance Capacitive loading Supply voltage (± 5 %) Current consumption 140 0 .. ± 200 10 200 V / 10 V ≥1 ≤5 ± 15 32 + VS / R L V V V Overall accuracy @ VP maxi VO Offset voltage @ VP = 0 TA = 25°C - 40°C .. + 85°C TA = 25°C - 40°C .. + 85°C tr Response time 1) to 90 % of VPN step dv/dt dv/dt accurately followed BW Frequency bandwidth (- 1 dB) @ VPN Maxi ± 0.2 ± 0.6 ± 5.0 ± 13.0 0.3 200 DC .. 300 • Closed loop (compensated) voltage transducer kΩ nF V mA • Isolated plastic case recognized according to UL 94-V0 • Patent pending. Advantages Accuracy - Dynamic performance data XG Features % % mV mV µs V/µs kHz • • • • • • Excellent accuracy Very good linearity Low thermal drift Low response time High bandwidth High immunity to external interference • Low disturbance in common mode. Applications • AC variable speed drives and servo General data motor drives TA TS P R1 m Ambient operating temperature Ambient storage temperature Total primary power loss Primary resistance Mass Standards - 40 .. + 85 °C - 45 .. + 90 °C 3.1 W 6.4 kΩ 560 g EN 50155: 1995 • Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies (UPS) • Power supplies for welding applications. Application domain Note: 1) With a dv/dt of 200 V/µs. • Traction. Page 1/3 061219/10 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com Current Transducer CV 3-200 Isolation characteristics Vd Ve Rms voltage for AC isolation test, 50 Hz, 1 min Partial discharge extinction voltage rms @ 10pC 6 2 dCp dCl CTI Creepage distance Clearance distance Comparative Tracking Index (Group I) 83.8 76.4 600 kV kV mm mm Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 061219/10 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com Dimensions CV 3-200 (in mm. 1 mm = 0.0394 inch) Front view Left view Secondary terminals Terminal Terminal Terminal Terminal + M 0 - : : : : supply voltage + 15 V measure 0V supply voltage - 15 V Connection Top view Mechanical characteristics • General tolerance • Transducer fastening Fastening torque maxi • Connection of primary • Connection of secondary Fastening torque maxi Remarks ± 0.3 mm 3 holes ∅ 5.5 mm M5 steel screws 3.8 Nm or 2.80 Lb. -Ft. M5 threaded studs M5 threaded studs 2.2 Nm or 1.62 Lb. -Ft. • VS is positive when VP is applied on terminal +HT. • CEM tested with a shielded secondary cable. Shield connected to 0 V at both ends, or disconnected. • This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 3/3 061219/10 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com