Twin Fixture - Big Ass Fans
Transcription
Twin Fixture - Big Ass Fans
INSTALLATION GUIDE Twin High Bay LED For help, call 877-BIG FANS or visit www.bigasslight.com/service Questions? Customers in the United States For questions about your product, please contact a customer service representative at 877-BIG FANS (877-244-3267) or visit www.bigasslight.com/service Customers outside the United States For questions about your product or customer service inquiries, please contact your local Big Ass Light representative or fill out a contact form at www.bigasslight.com/service Installation Guide January 2015 Rev. B Model number: BAL-HBL1-40XXXXXX BAL-HBL1-52XXXXXX Conforms to UL Standard 1598, UL Standard 8750, CSA Standard C22.2 No. 250.0, and CSA Standard C22.2 No. 250.13 This product was manufactured in a plant whose Management System is certified as being in conformity with ISO 9001:2008. May be protected by one or more of the following patents: www.bigasssolutions.com/patents Contents Introduction Important Safety Information�������������������������������������������������1 Parts Included�����������������������������������������������������������������������2 Assembly 1. Position Fixtures Side-by-Side������������������������������������������3 2. Clamp the Fixtures Together���������������������������������������������3 4. Open Enclosure�����������������������������������������������������������������4 6. Screw Enclosure Onto Fixtures�����������������������������������������5 7. Wire and Hang������������������������������������������������������������������5 Wiring Basic Wiring��������������������������������������������������������������������������7 Wiring With External Dimming�����������������������������������������������8 Wiring With Onboard Dimming����������������������������������������������9 Wiring With Onboard Occupancy Sensor����������������������������10 Defaults Default Occupancy Sensor Settings������������������������������������11 Maintenance Electrical Preventive Maintenance��������������������������������������13 Removing and Replacing the Lenses����������������������������������13 Cleaning the Lenses������������������������������������������������������������13 TWIN HIGH BAY LED © 2014 BIG ASS LIGHT, LLC. ALL RIGHTS RESERVED WWW.BIGASSLIGHT.COM Introduction 1 This guide contains important instructions and safety information. Leave these instructions with the owner after installation. Important safety information ! WARNING: Disconnect power before servicing. ! WARNING: This product contains high intensity LED devices. To prevent permanent eye damage, do not stare into the light beam at close range. ! The installation of Big Ass Light products must be performed by qualified person(s) in accordance with all applicable codes. Code compliance is your responsibility. Failure to comply with these codes could result in personal injury or property damage. Suitable for operation in ambient temperatures not exceeding 55°C. Suitable for damp locations. Not for use in dwellings. Ensure power is routed to an approved outlet box at the ceiling before beginning installation. Support the fixture so that it does not fall during installation. TWIN HIGH BAY LED © 2014 BIG ASS LIGHT, LLC. ALL RIGHTS RESERVED WWW.BIGASSLIGHT.COM 2 Introduction (cont.) Parts included Note: Drawings below are not to scale. (2) Single Fixture Enclosure Assembly1 (1) Enclosure (1) Power Cable (1) Dimming Cable2 (4) 6-20 Pan Head Screw (1) 3/4” NPT Cord Grip (1) 3/4” NPT Lock Nut (1) 3/4” NPT Conduit Hub (1) 1/2” NPT Cord Grip (1) 1/2” NPT Lock Nut (2) 5-Conductor Splicing Connector (4) 3-Conductor Splicing Connector (7) 12” Wire, Assorted Colors (not shown) Clamp Assembly (4) Clamp Bracket (4) 1/4-20 Hex Head Screw (4) 1/4-20 Hex Nut (2) Y Cable, 20 ft (6 m) 1. Installation may not require all provided parts. See the assembly and wiring instructions for details. 2. Not provided if occupancy sensor is included with the enclosure. TWIN HIGH BAY LED © 2014 BIG ASS LIGHT, LLC. ALL RIGHTS RESERVED WWW.BIGASSLIGHT.COM Assembly 3 1. Position fixtures side-by-side Make sure same-size holes are aligned as shown. 2. Clamp the fixtures together Make sure the clamp brackets fit snugly. If they are loose, rotate one bracket and fit them back together as shown. Make sure fit is snug Brackets should fit snugly If misaligned, rotate one bracket Slide a pair of clamp brackets out to the endcap. Clamp as shown, tightening to approximately 12 in·lb (1.4 N·m). Repeat on the other end of the fixture. Clamp assembly hardware a. (4) 1/4-20 Hex Nut b. (4) 1/4-20 Hex Head Screw c. (4) Clamp Bracket Clamp at endcap a c TWIN HIGH BAY LED © 2014 BIG ASS LIGHT, LLC. b b ALL RIGHTS RESERVED WWW.BIGASSLIGHT.COM 4 Assembly (cont.) 4. Open enclosure Remove screws as shown to remove the endplates and top panel of the enclosure. Note: Reserve screws to reassemble the enclosure after wiring. OR TWIN HIGH BAY LED © 2014 BIG ASS LIGHT, LLC. ALL RIGHTS RESERVED WWW.BIGASSLIGHT.COM 5 Assembly (cont.) 6. Screw enclosure onto fixtures Position the enclosure and fixtures so corresponding holes and knockouts are aligned as shown below. Screw the enclsoure to the fixtures. Enclosure hardware a. (4) 6-20 Pan head screw Align knockouts and holes a Power (3/4” NPT) Dimming (1/2” NPT) 7. Wire and hang ! WARNING: Do not use conduit to support the weight of the fixture. Always hang twinned fixtures using the provided cables. Secure the 12” (30 cm) green wire in the ground lug inside the enclosure. Refer to the following instructions to wire the fixture: Basic Wiring�������������������������������������������������������������������������������������������7 Wiring With External Dimming����������������������������������������������������������������8 Wiring With Onboard Dimming���������������������������������������������������������������9 Wiring With Onboard Occupancy Sensor���������������������������������������������10 After wiring the fixture, close the enclosure and secure with reserved screws. Hang the fixture at least 2 ft (0.6 m) from the ceiling using the provided cables. TWIN HIGH BAY LED © 2014 BIG ASS LIGHT, LLC. ALL RIGHTS RESERVED WWW.BIGASSLIGHT.COM Wiring 7 Basic wiring L1 GROUND (GREEN) Facility Power L2 Enclosure Ground Lug GROUND Remove enclosure knockouts as needed. Connect as shown below. GROUND (GREEN) GROUND (GREEN) Fixture L2 (WHITE) L2 (WHITE) L1 (BLACK) L1 (BLACK) Fixture’s L1 (black) connects to Fixture’s L2 (white) connects to 120 VAC, 1 Ф derived from 1 Ф, 240/120 V panel H (black) N (white) 208 VAC, 3 Ф derived from 3 Ф, 208/120 V panel L1 (black), L2 (red), or L3 (blue) L2 (red), L3 (blue), or L1 (black) 240 VAC, 1 Ф derived from 1 Ф, 240/120 V panel L1 (black) L2 (red) 240 VAC, 1 Ф derived from 3 Ф, 240/120 V panel, B phase wild L1 (black), L2 (orange), or L3 (blue) L2 (orange), L3 (blue), or L1 (black) 277 VAC, 1 Ф derived from 3 Ф, 480/277 V panel L1 (brown), L2 (orange), or L3 (yellow) N (white) 347 VAC, 1 Ф derived from 3 Ф, 600/347 V panel L1 (red), L2 (black), or L3 (blue) N (white) 480 VAC, 3 Ф derived from 3 Ф, 480/277 V panel L1 (brown), L2 (orange), or L3 (yellow) L2 (orange), L3 (yellow), or L1 (brown) 480 VAC, 1 Ф derived from 3 Ф, 480 V panel, corner ground L1 (brown) or L3 (yellow) L2/Grounded conductor (white or gray) All Low voltage fixture (120–277 V ± 15%) Supply voltage High voltage fixture (347–480 V ± 15%) Fixture TWIN HIGH BAY LED © 2014 BIG ASS LIGHT, LLC. ALL RIGHTS RESERVED WWW.BIGASSLIGHT.COM 8 Wiring (cont.) Wiring with external dimming Remove enclosure knockouts as needed. Connect as shown below. L1 GROUND (GREEN) Facility Power L2 GROUND Enclosure Ground Lug GROUND (GREEN) GROUND (GREEN) L2 (WHITE) L2 (WHITE) L1 (BLACK) L1 (BLACK) DIM+ (VIOLET) DIM+ (VIOLET) DIM- (GRAY) DIM(GRAY) Facility Dimming (1–10 V DC) Fixture’s L1 (black) connects to Fixture’s L2 (white) connects to 120 VAC, 1 Ф derived from 1 Ф, 120/240 V panel H (black) N (white) 208 VAC, 3 Ф derived from 3 Ф, 120/208 V panel L1 (black), L2 (red), or L3 (blue) L2 (red), L3 (blue), or L1 (black) 240 VAC, 1 Ф derived from 1 Ф, 120/240 V panel L1 (black) L2 (red) 240 VAC, 1 Ф derived from 3 Ф, 120/240 V panel, B phase wild L1 (black), L2 (orange), or L3 (blue) L2 (orange), L3 (blue), or L1 (black) 277 VAC, 1 Ф derived from 3 Ф, 277/480 V panel L1 (brown), L2 (orange), or L3 (yellow) N (white) 347 VAC, 1 Ф derived from 3 Ф, 347/600 V panel L1 (red), L2 (black), or L3 (blue) N (white) 480 VAC, 3 Ф derived from 3 Ф, 277/480 V panel L1 (brown), L2 (orange), or L3 (yellow) L2 (orange), L3 (yellow), or L1 (brown) 480 VAC, 1 Ф derived from 3 Ф, 480 V panel, corner ground L1 (brown) or L3 (yellow) L2/Grounded conductor (white or gray) All Low voltage fixture (120–277 V ± 15%) Supply voltage High voltage fixture (347–480 V ± 15%) Fixture DIM- (GRAY) DIM+ (VIOLET) Fixture TWIN HIGH BAY LED © 2014 BIG ASS LIGHT, LLC. ALL RIGHTS RESERVED WWW.BIGASSLIGHT.COM Wiring (cont.) 9 Wiring with onboard dimming Refer to the example illustrations below to determine where to place your dimmer along the center wall of the enclosure so that the dimming and power wires remain on their respective sides. Remove the corresponding knockout in the center wall and secure the dimmer in place. Connect the fixture to power as shown on page 5. Wire and configure the dimmer according to the dimmer manufacturer’s instructions. TWIN HIGH BAY LED © 2014 BIG ASS LIGHT, LLC. ALL RIGHTS RESERVED WWW.BIGASSLIGHT.COM 10 Wiring (cont.) Wiring with onboard occupancy sensor 120/277 V fixtures only Remove enclosure knockouts as needed. Connect as shown below. Fixture GROUND (GREEN) L2 (WHITE) DIM+ (VIOLET) L1 (BLACK) DIM- (GRAY) Occupancy Sensor Facility Power LOAD (RED) DIM+ (VIOLET) L1 LINE (BLACK) L2 NEUTRAL (WHITE) DIM- (GRAY) GROUND (GREEN) GROUND GROUND (GREEN) Fixture Enclosure Ground Lug L1 (BLACK) L2 (WHITE) GROUND (GREEN) DIM+ (VIOLET) DIM- (GRAY) Sensor’s Line (black) connects to Fixture’s L2 (white) and sensor’s Neutral (white) connect to 120 VAC, 1 Ф derived from 1 Ф, 120/240 V panel H (black) N (white) 208 VAC, 3 Ф derived from 3 Ф, 120/208 V panel L1 (black), L2 (red), or L3 (blue) L2 (red), L3 (blue), or L1 (black) 240 VAC, 1 Ф derived from 1 Ф, 120/240 V panel L1 (black) L2 (red) 240 VAC, 1 Ф derived from 3 Ф, 120/240 V panel, B phase wild L1 (black), L2 (orange), or L3 (blue) L2 (orange), L3 (blue), or L1 (black) 277 VAC, 1 Ф derived from 3 Ф, 277/480 V panel L1 (brown), L2 (orange), or L3 (yellow) N (white) Supply voltage TWIN HIGH BAY LED © 2014 BIG ASS LIGHT, LLC. ALL RIGHTS RESERVED WWW.BIGASSLIGHT.COM Default Occupancy Sensor Settings 11 Occupancy sensors are programmed with the following default settings: High Mode..................... 10 V Sensitivity...................... Max Low Mode ..................... 1 V Setpoint......................... None Time Delay.................... 5 min Ramp Up....................... None Cut Off........................... 1 hr Fade Down.................... None Force Off Setpoint with Occupied..................................................Disable Note: Because Setpoint is set to “None,” lights will return to full brightness whenever the sensor detects motion. These settings can be modified at any time using the handheld remote programming device. For further assistance, contact Customer Service. TWIN HIGH BAY LED © 2014 BIG ASS LIGHT, LLC. ALL RIGHTS RESERVED WWW.BIGASSLIGHT.COM Maintenance 13 Electrical preventive maintenance Big Ass Light suggests an electrical preventive maintenance program similar to that described in NFPA 70B: Recommended Practice For Electrical Equipment Maintenance by the National Fire Protection Association. Removing and replacing the lenses The lenses are designed to be removable for cleaning or replacement. Note: Handle lenses with care. To remove a lens, grasp the end grip and gently slide the lens out as shown. To insert a lens, slide in and push firmly until the grip is flush with the edge of the fixture. Cleaning the lenses ! CAUTION: Do not clean the fixture—especially the lenses—with scouring pads, alkaline cleaning substances, gasoline, thinner, benzene, heating oil, glycol, alcohol, or polishing powder. ! CAUTION: Do not pressure wash or use a water hose to clean the fixture. Clean the lenses periodically to ensure optimal performance. Remove lenses and wipe with a clean, damp cloth. Allow to dry thoroughly before replacing. If necessary, use a mild soap or a gentle liquid cleaner. TWIN HIGH BAY LED © 2014 BIG ASS LIGHT, LLC. ALL RIGHTS RESERVED WWW.BIGASSLIGHT.COM BAL-INST-34-MUL-01 REV B 2425 Merchant St., Lexington, KY 40511 1 (877) BIG-FANS | WWW.BIGASSFANS.COM