SIMATIC Microbox PC 427B - Siemens Industry Online Support
Transcription
SIMATIC Microbox PC 427B - Siemens Industry Online Support
Automation and Drives SIMATIC Microbox PC 420 s imatic pc Technical Information SIMATIC Microbox PC 427B Automation and Drives SIMATIC Microbox PC 427B – Developed in Accordance with Customer Requirements SIMATIC Microbox PC 427B Requirements Requirements Basic customer requirements Technical characteristics High compactness Dimensions/volume with functionality High ruggedness EMC Technical Data Temperature Features PC104 Shock/ vibration Zero Maintenance Windows® XPe Other Operating Systems Data Back-Up BIOS EMC-tight full-metal enclosure Isolated power supply Large heat sink to the outside directly on processor Low-voltage CPU/chipset CompactFlash card Rugged enclosure High system availability 24-h continuous operation / 365 days Zero maintenance Without fans Without hard disks (option) Without CMOS battery (option) Ease of mounting Standard mounting rail Wall Access protection BIOS password XPe configuration Upgradeability Profibus DP 3 x PCI-104 4 x USB 2.0 State-of-the-art technology SIMATIC Microbox PC 427B – Technical Information DDR2 RAM Gbit-LAN (via PCI-Express) DVI-I 32-bit buffered SRAM A&D SE IPC, 01/2007 2 Automation and Drives SIMATIC Microbox PC 427B Technical Data Subject to technical changes/improvements. SIMATIC Microbox PC 427B Basic data Requirements Mounting / installation position Standard rail mounting Wall mounting Installation position: horizontal (preference) and vertikal Processor Intel Celeron M 900 MHz, 400 MHz FSB, SLC 0Kb, ULV Intel Celeron M 1 GHz, 400 MHz FSB, SLC 512Kb, ULV 373 Intel Pentium M 1.4 GHz, 400 MHz FSB, SLC 2Mb, LV 738 Chipset Intel Alviso 910GML Main memory Free extension slots Up to 3 x PCI-104 (with extension frame) 3 W per slot Graphics Integrated Intel 2D/3D GMA900 graphics accelerator 8 to 128 MB shared graphics memory (dynamically managed) Resolution CRT: 640*480 pixels up to max. 1600*1200 pixels / true color / 60 to 120 Hz Resolution DVI-D: 640*480 pixels up to max. 1600*1200 pixels / true color Power supply 24 V DC; 20.4 ... 28.8 V DC Isolated Application conditions Without fan Technical Data Technical Data Features PC104 Zero Maintenance Windows® XPe Other Operating Systems Data Back-Up BIOS SIMATIC Microbox PC 427B – Technical Information 256 MByte DDR2-SDRAM or 512 MByte DDR2-SDRAM or 1 GByte DDR2-SDRAM or 2 GByte DDR2-SDRAM A&D SE IPC, 01/2007 3 Automation and Drives SIMATIC Microbox PC 427B Technical Data SIMATIC Microbox PC 427B Subject to technical changes/improvements. Drives SIMATIC PC CompactFlash Replaceable (accessible): 256 Mbyte, 512 Mbyte, 1 Gbyte or 2 Gbyte optional Internal (not accessible): 1 Gbyte or 2 Gbyte optional High-performance, industrial-grade CompactFlash PC104 Hard disk ≥ 60 Gbyte SATA optional Zero Maintenance Floppy /CD-ROM drive/ USB stick Connectable via USB interface Not included in scope of supply Requirements Technical Data Technical Data Features Windows® XPe Other Operating Systems Interfaces Serial COM1 (RS232) Data Back-Up Graphical DVI-I: DVI and VGA combined BIOS USB 4 x USB V 2.0 / high-speed (480 Mbit/sec) Additional strain relief option included in accessories kit Ethernet PROFIBUS DP/MPI 12 Mbit/sec (isolated, CP 5611-compatible), optional With exclusive, non-shared interrupt Other field buses upon request Keyboard, mouse Connectable via USB interface SIMATIC Microbox PC 427B – Technical Information 2 x 10/100/1000 Mbit/sec (RJ 45) 2 independent Intel controllers 82573L (via PCI-Express) One controller with exclusive, non-shared interrupt Both interfaces are teaming-capable A&D SE IPC, 01/2007 4 Automation and Drives SIMATIC Microbox PC 427B Technical Data Subject to technical changes/improvements. SIMATIC Microbox PC 427B Requirements Safety functions Technical Data Technical Data Watchdog Temperature monitoring Processor and basic board (via SIMATIC PC DiagMonitor) Hour meter Via SIMATIC PC DiagMonitor LED display 4 LEDs for system state display 2 of which are freely programmable by the user (each two-colored: yellow/green and yellow/red) Short-time voltage interruption Up to 5 msec Then buffering for at least another 10 msec Network failure signaling through power fail signal Buffer memory 2 Mbyte battery-buffered SRAM 128 kbyte of which are writable within the buffer time Features PC104 Zero Maintenance Program sequence monitoring Monitoring time parameterizable via software Restart parameterizable for fault cases Evaluation of the application program‘s fault states (locally, via LAN) Windows® XPe Other Operating Systems Data Back-Up BIOS SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 5 Automation and Drives SIMATIC Microbox PC 427B Technical Data Subject to technical changes/improvements. SIMATIC Microbox PC 427B Requirements Operating systems Technical Data Technical Data Orderable Without Windows® XP embedded® pre-installed, no activation required in connection with SIMATIC PC CompactFlash ≥ 512 Mbyte or hard disk Windows® XP Professional®, no activation required in connection with hard disk RMOS3 as independent product Project-specific Features PC104 Zero Maintenance Windows® XPe Other Operating Systems Data Back-Up BIOS SIMATIC Microbox PC 427B – Technical Information Linux QNX® VxWorks® Others A&D SE IPC, 01/2007 6 Automation and Drives SIMATIC Microbox PC 427B Technical Data SIMATIC Microbox PC 427B Requirements Technical Data Technical Data Subject to technical changes/improvements. Ambient conditions General In accordance with SIMATIC SPH environment Degree of protection IP 20 in accordance with EN 60529 Vibration Device without hard disk: Requirements in accordance with: IEC 61131-2 Testing in accordance with: IEC 60068-2-6, test Fc 5-9 Hz, 3.5 mm deflection, 10x /axis, 1 octave/min 9-150 Hz, 9.8 m/s2, 10x /axis, 1 octave/min Features PC104 Zero Maintenance Device with hard disk: wall mounting Requirements in accordance with: IEC 61131-2 Testing in accordance with: IEC 60068-2-6, test Fc 10-58 Hz, 0.0375 mm deflection, 10x /axis, 1 octave/min Windows® XPe Other Operating Systems Data Back-Up BIOS 58-200 Hz, 4.9 m/s2, 10x /axis, 1 octave/min Shock SIMATIC Microbox PC 427B – Technical Information Device without hard disk: Requirements in accordance with: IEC 61131-2 Testing in accordance with: IEC 60068-2-27, test Ea Module/rack: 150 m/s2, acceleration, 11 msec shock duration Device with hard disk: wall mounting Requirements in accordance with: IEC 61131-2 Testing in accordance with: IEC 60068-2-27, test Ea Devices with drives: 50 m/s2, acceleration, 30 msec shock duration A&D SE IPC, 01/2007 7 Automation and Drives SIMATIC Microbox PC 427B Technical Data SIMATIC Microbox PC 427B Requirements Technical Data Technical Data Features PC104 Zero Maintenance Windows® XPe Other Operating Systems Data Back-Up BIOS Subject to technical changes/improvements. Ambient conditions Electromagnetic compatibility (EMC): Interference emission Interference resistance to transient disturbance variables Interference resistance to surge voltages Interference resistance to electrostatic discharge Interference resistance to high-frequency irradiation Interference resistance to high-frequency power supply on lines Interference resistance to magnetic fields EN 55022 class B ± 2 kV (IEC 61000-4-4, burst) ± 1 kV (IEC 61000-4-5, surge symmetrical) ± 2 kV (IEC 61000-4-5, surge asymmetrical) ± 6 kV, contact discharge (IEC 61000-4-2) ± 8 kV, air discharge (IEC 61000-4-2) 10 V/m, 80% AM (1 kHz), 80 MHz to 1 GHz (IEC 61000-4-3) 10 V/m, 50% PM, 1.4 GHz to 2 GHz (IEC 61000-4-3) 10 V, 80% AM (1kHz), 10 kHz to 80 MHz (IEC 61000-4-6) 100 A/m effective value, 50/60 Hz (IEC 61000-4-8) Ambient temperature during operation (depending on installation position) 0 to 55 ºC with CompactFlash card (horizontal, with derating) 0 to 50 ºC with CompactFlash card (horizontal) 0 to 45 ºC with CompactFlash card (vertical) 5 to 40 ºC with hard disk (horizontal and vertical) Humid heat With CompactFlash card: 95% With hard disk: 80% SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 8 Automation and Drives SIMATIC Microbox PC 427B Technical Data SIMATIC Microbox PC 427B Requirements Subject to technical changes/improvements. Approvals Safety standards IEC 61131-2 IEC 61010-1 EN 60950-1 Approvals cULus approval in accordance with UL 60950 and UL 508 CE-conformity EC directive 89/336/EEC (EMC directive) Application in industrial environments: Interference emission: EN 61000-6-4 Interference resistance: EN 61000-6-2 Application in residential, business and commercial environments as well as small companies: Interference emission: EN 61000-6-3 Interference resistance: EN 61000-6-1 Technical Data Technical Data Features PC104 Zero Maintenance Windows® XPe Other Operating Systems Data Back-Up BIOS Dimensions and weights Installation dimensions Width x height: Depth basic device: Depth basic device from standard mounting rail: Additional depth per extension (1-3): Weight Approx. 2 kg MLFB body 6ES7647-7A SIMATIC Microbox PC 427B – Technical Information 262 x 134 mm 47 mm 50 mm +17 mm each A&D SE IPC, 01/2007 9 Automation and Drives Further Features SIMATIC Microbox PC 427B Microbox offers: Benefits: Reset button Device reset during commissioning without disconnection of the supply voltage Little influence on the overall process No noise development Thanks to the abolishment of fans and hard disk, application also possible in acoustically sensitive areas Status LEDs Serve visual support during: commissioning / operation / servicing Easy and fast diagnostics without auxiliary tools Lower power consumption (approx. ≥ 15 W) than standard PCs Smaller dimensioning of the upstream 24 V power supply possible Compact design thanks to reduced heat development Cable clamp for USB plug Compliance with vibration/shock values also without cable clamp Further improved mechanical design thanks to the cable clamp included in the scope of supply Isolated power supply Power monitoring Query of the battery status for increased system availability Two-level execution of the monitoring function Headless operation Support of system configurations without monitor Start-up possible without monitor and keyboard Monitor can be subsequently connected for diagnostic purposes Requirements Technical Data Features Features PC104 Zero Maintenance Windows® XPe Other Operating Systems Data Back-Up BIOS SIMATIC Microbox PC 427B – Technical Information Prevention of potential transfers Improved system reliability Support of eased potential/grounding concepts Application without additional measures A&D SE IPC, 01/2007 10 Automation and Drives PCI-104 General Information SIMATIC Microbox PC 427B Requirements (also see: http://www.pc104.org/) Technical Data Features PC104 Windows® XPe = = = ISA bus (8 or 16 Bit) ISA bus + PCI-Bus PCI bus (without PC/104) PCI104 and PC/104-Plus cards are consistently usable (use of PCI signals) Old PC104 cards (only ISA bus) are not usable Up to three PC/104 modules can be integrated Data Back-Up BIOS PC/104 PC/104-Plus PCI104 Microbox PC 427B is equipped with a PCI104 interface Zero Maintenance Other Operating Systems Specifications in accordance with the PC/104 committee With extension frame Numerous suppliers of basic and special functions No manufacturer offers a full-range portfolio The long-term availability of PC104 modules from the embedded market bears considerable customer benefits Typical 3 W power consumption per slot possible Two "non-shared interrupts" available for high-performance extensions Optimum EMC connection of interfaces through slot plates on the extension frames SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 11 Automation and Drives Extension Frame SIMATIC Microbox PC 427B Requirements Technical Data Features PC104 Zero Maintenance Windows® XPe Other Operating Systems Data Back-Up BIOS Extension frame Required for the integration of PC104 modules Extend the enclosure towards the front and create space for modules Can be modularly stacked Can be ordered separately as extension kit Extension kit PC/104 6AG4070-0BA00-0XA0 6 extension frames, including mounting material and slot plates 1 extension frame (17 mm) required per PC104 module The basic device's front cover also serves as front-side cover when using the extension frame. Any interfaces of the PC104 modules are routed to the extension frame‘s slot plates via short cables. SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 12 Automation and Drives I/O Cards Selection and Integration SIMATIC Microbox PC 427B Requirements Technical Data Features PC104 Zero Maintenance Windows® XPe Other Operating Systems Data Back-Up BIOS A&D SE IPC provides support in the form of pre-sales services regarding the selection and integration of PC104 extension modules. Integration by customers or by the IPC Customization Center The following steps must be performed by customers: Routing the connection cable between the PC104 module and the slot plate these are partially included in the modules‘ scope of supply Placing cutouts in the slot plates for the interface plugs PC104 modules can be integrated in the Microbox PC by means of customizing, for which the above-mentioned steps have to be performed. The delivery conditions of the manufacturers apply SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 13 Automation and Drives Zero Maintenance SIMATIC Microbox PC 427B Requirements Technical Data Features The zero maintenance of the Microbox PC results from the complete abolishment of rotating parts, i.e.: PC104 Zero Maintenance Maintenance Windows® XPe Other Operating Systems Data Back-Up Abolishment of fans and abolishment of a hard disk by focusing on CompactFlash operation – as far as permitted by the application. Moreover, a battery is not necessarily required, only if remanent data are to be stored in the SRAM due to: Remanent storage of setup data (settable in BIOS) Time synchronization possible via LAN (via DiagMonitor) BIOS The Microbox PC offers zero maintenance if the hard disk and battery can be done away with! SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 14 Automation and Drives Operating Systems Windows® XP embedded SIMATIC Microbox PC 427B Requirements Technical Data Features PC104 Zero Maintenance Why Windows XP embedded? The bulk memory requirement of Windows XP Professional is too large for a CompactFlash-based system The license costs of Windows XP embedded are considerably lower than those of Windows XP Windows® XPe Windows® XPe Other Operating Systems Data Back-Up BIOS Windows XP embedded contains additional features for embedded applications, e.g.: Enhanced write filter: Activatable write protection for partitions to increase system stability Message box interception: Configurable output suppression of system and fault messages for unattended systems SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 15 Automation and Drives Operating Systems Windows® XP embedded SIMATIC Microbox PC 427B Requirements Technical Data Features PC104 Zero Maintenance Windows® XPe Windows® XPe Other Operating Systems Windows XP embedded is pre-installed on the Microbox PC to allow for manifold applications Can the customer subsequently install, e.g., Microsoft Word? Data Back-Up BIOS Small size facilitates application on CF card 512 Mbyte or larger Standard drivers/functions included, e.g. CD-ROM, memory stick, print service, UPS support, etc. If required, drivers can be subsequently installed The pre-installed Windows XP embedded is system-tested Turn-key system Cost reductions in terms of system generation, tests and commissioning Yes. For license reasons, the Microsoft Office packages must only be used application-specifically; no general use (e.g. letter preparation) permissible. Incl. Service Pack 2 Feature Pack 2007 Latest hot fixes and security patches for increased system reliability Booting of USB bulk memories, e.g. to boot USB flash drives in service cases Improved Enhanced Write Filter (EWF) allows, e.g., for the write protection for individual files instead of partitions only SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 16 Automation and Drives Windows® XP embedded Optimization SIMATIC Microbox PC 427B Requirements Technical Data Features PC104 Zero Maintenance Windows® XPe Windows® XPe Other Operating Systems Data Back-Up If required, XPe can be further optimized for special applications Adding of components not contained in the standard image Reduced demand for CF cards thanks to abolishment of unnecessary components A special tool chain (Target Designer) and respective know-how are required for these adjustments A&D SE IPC CC offers a project-specific generation of XP embedded BIOS SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 17 Automation and Drives Windows® XP embedded Basic Images SIMATIC Microbox PC 427B Requirements Two basic versions cover the basic requirements. Technical Data Features PC104 Zero Maintenance Windows® XPe Windows® XPe Other Operating Systems Data Back-Up 1. Basic image for applications in rough environments Application on Microbox with CF card ( Restricted Windows functional scope Full interface support Enhanced Write Filter enabled Support of Win AC Basis 512 Mbyte) BIOS 2. Basic image for universal applications Application on Microbox with hard disk Full functional scope of XP Professional Subsequent installation of any customer software Enhanced Write Filter possible but not enabled SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 18 Automation and Drives Windows® XP embedded Updates / Virus Scan / Firewall SIMATIC Microbox PC 427B Requirements Updates Technical Data Features PC104 Zero Maintenance Windows® XPe Windows® XPe Other Operating Systems Virus scanner Data Back-Up BIOS XPe fillings contain a “Desktop Update” component for the subsequent installation of XP Professional hot fixes via USB devices (CD-ROM, USB stick ..) or via LAN Subsequent installation of complete service packages not possible Microsoft offers correspondingly updated components for XPe time-delayed to the respective service packs . These components are integrated in the XPe fillings as required. With its configurable Enhanced Write Filter (EWF), XPe offers a better protection against viruses than Windows XP Professional A virus scan can be installed, updates are carried out with the conventional mechanisms as with XP-Professional in consideration of the EWF (disabling with installations) via USB devices (CD-ROM, USB stick ..) or via LAN Firewall The XPe fillings of the Microbox contain the “Internet Connection Firewall” It has to be configured by the end user SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 19 Automation and Drives Operating Systems Others SIMATIC Microbox PC 427B Requirements Technical Data Features Thanks to the standard architecture, also other operating systems can be employed. Installation and switch-on test with Suse Linux Further operating systems (QNX, VxWorks ...) upon request PC104 Zero Maintenance Windows® XPe Other Other Operating Systems Operating Systems Data Back-Up BIOS Project-specific solutions are realized by the SIMATIC PC Customization Center. If required, a customer-provided software image can be pre-installed ex works. Realtime operating system SICOMP RMOS3 system-tested on Microbox PC 427B SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 20 Automation and Drives Back-Up and Restoration SIMATIC Microbox PC 427B Requirements Technical Data Features PC104 Zero Maintenance Windows® XPe Other Operating Systems Data Back-Up Data Back-Up BIOS A restore DVD is included in the standard scope of supply. For data back-up and restoration, the standard IPC tools ("SIMATIC PC/PG Image & Partition Creator“) or comparable products can be used. With the CompactFlash version, the application of a PCMCIA adapter in the programming device is recommendable. For monitoring the Microbox PC, the "SIMATIC PC DiagMonitor" monitoring and remote signaling software can be employed. SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 21 Automation and Drives Restore DVD SIMATIC Microbox PC 427B Requirements Technical Data Features PC104 The restore DVD contains the as-delivered XPe image of the SIMATIC Microbox PC 427B for the respective filling Transfer of the image to the hard disk / CF card via Ghost (component DVD) Delivery of SIMATIC Microbox PC without restore DVD Customers can order the restore DVD from the Customer Support Zero Maintenance Windows® XPe Other Operating Systems SIMATIC Microbox PC Data Back-Up Data Back-Up BIOS Siemens CS Fuerth + Customer application Customer Restore DVD SIMATIC Microbox PC + Customer application SIMATIC Microbox PC + Customer application SIMATIC Microbox PC + Customer application Machine image + Customer application SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 22 Automation and Drives Data Back-Up via Buffered SRAM SIMATIC Microbox PC 427B 2 Mbyte SRAM for data back-up in case of network failures Requirements Data storage via integrated battery Technical Data Features PC104 Zero Maintenance Windows® XPe Other Operating Systems Data Back-Up Data Back-Up High-performance bus interface (32-bit PCI, memory-mapped) High-capacity battery (> 5-year service life) Remanence strategies Cyclic storage of important data Storage of all required data in case of network failure Initialization of data recovery via Powerfail and NMI Storage time after interrupt at least 10 msec, depending on HW configuration Currently application-specific implementation of data back-up Network failure BIOS NMI, initialization of the interrupt service routine 1-3msec frequent normal voltage interruptions Computer power OFF Storage time in full configuration 10 msec (with max. power demand) 5msec SIMATIC Microbox PC 427B – Technical Information min. 10 msec A&D SE IPC, 01/2007 23 Automation and Drives Microbox PC Data Back-Up Customer Benefits SIMATIC Microbox PC 427B Requirements Technical Data Features PC104 Zero Maintenance Important data can be rapidly stored in the battery-buffered SRAM even after switch-off Faster writing of small data volumes on SRAM than on CompactFlash or hard disk WinAC can store data blocks and continue operation with the saved data upon the next start- up Windows® XPe Other Operating Systems SRAM on-board, i.e. no additional HW (memory board) required Data Back-Up Data Back-Up BIOS SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 24 Automation and Drives Microbox PC Data Back-Up Status Win XPe SIMATIC Microbox PC 427B Requirements Technical Data Features PC104 Zero Maintenance Windows® XPe Other Operating Systems Data Back-Up Data Back-Up Windows XPe works with the same mechanisms as Windows XP Professional Storage of remanent data in the SRAM via access to memory in the SRAM by employing an I/O driver (e.g. IMCEA driver) via WinAC and use of suitable remanence library Data back-up is carried out application-specifically by means of suitable cyclic storage measures BIOS Safe shutdown in case of voltage failures (incl. prior storage of open files) via UPS SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 25 Automation and Drives BIOS SIMATIC Microbox PC 427B Requirements Technical Data Features PC104 Zero Maintenance Windows® XPe Other Operating Systems Data Back-Up BIOS Boot devices CompactFlash disk Hard disk USB floppy disk USB optical disk (CD, DVD) USB memory stick LAN via PXE (preboot execution environment) Adjustment of Microbox PC-specific functions Watchdog Field bus interface IDE operating mode enhanced / legacy Setup values can be stored in EPROM. Legacy support for keyboard, mouse and drives USB2.0 legacy support USB drivers have to be available for realtime applications Unique number (stored via DMI) SIMATIC Microbox PC 427B – Technical Information A&D SE IPC, 01/2007 26