Eco DC Brushless Ventilation Fan

Transcription

Eco DC Brushless Ventilation Fan
Improve Indoor Air Quality
Eco DC Brushless Ventilation Fan
www.sunon.com
Headquarters
Sunonwealth Electric Machine Industry Co., Ltd.
TEL:+886-7-8135888
E-mail:[email protected]
URL : www.sunon.com
Sunon SAS ( Europe )
TEL:+33-1-46154515
E-mail:[email protected]
2015/03/10 (009)
© 2015 SUNONWEALTH Electric Machine Industry Co., Ltd.
About Sunon
The world’s leading brand of DC brushless fans and blowers
Founded in 1980, Sunonwealth Electric Machine Industry Co., Ltd. has always adhered to the business
philosophy of “Brand, Innovation, and Value”. Step by step, it has now become a global leader in the fields of
precision motors, mini fans, and thermal modules.
SUNON’s concentration for more than 30 years on the research and development of core motor technology
enables it to release DC Motor Technology that set the pace for the industrial trend. Today SUNON has become
the best thermal solution provider for clients across various industries, such as IT, automobile electronics, optical
electronics, and network communication, LED, among other industries. In 2011, SUNON’s Mighty Mini Fan
accomplished NASA experiment in outer space.
SUNON research center
the driving engine for inventions and innovations
In 2002, SUNON established its invention & innovation center in Kaohsiung, Taiwan, and assigned it the
responsibility of planning, promoting, and executing the company's blueprint on innovation. Furthermore, the
center was also assigned the responsibility of integrating the company’s R & D laboratories and technicians in
Europe, the United States, Japan, and China to plan and build an invention & innovation team consisting of 400
professionals throughout the world and a technical services network that can respond rapidly and professionally.
Based on the “Trinity R & D theory”, SUNON has
been engaged in the research of motor technology
Applied materials research
for
Development and experiments of raw materials
nearly
30
years,
mainly
on
3
major
technological fields -- “motor invention”, “motor
applications”,
and
“total
solutions
for
heat
dissipation”-- and aims to explore the best
performance and unlimited possibilities of motor
applications.
SUNON’s persistent pursuit of
technical breakthrough and product innovation has
pushed
it
to
the
forefront
of
technology
development and enabled it to provide its clients
with key modules in the three major fields of
motors, cooling fans, and cooling modules to help
them to accomplish their goals on next generation
products.
01
SUNON Eco DC Brushless Ventilation Fan
Design, simulation,
Commercialization
and verification of
of motor applications
the total solution
SUNON reliability verification system
SUNON has 5 reliability testing labs worldwide equipped with the topmost precision verification instruments for
testing from the design phase, through pre-production, and into mass production. The complete verification system
is computerized and fully automated for precise analysis of product reliability and quality satisfaction to meet the
market requirements.
Sound Quailty
Analysis & Research
Sound Quailty Lab
Thermal Analysis
Blade Design
Magnetization
Simulation Analysis
SUNON production network
SUNON has established its business headquarters in Kaohsiung, Taiwan and set up various branches and offices
in Europe, the United States, Asia, and other places. These, together with its more than 100 distributors throughout
the world and some 1000 sales & service sites, constitute a large customer service and technical support network
that covers five continents of the world. In order to ensure sufficient capacity for mass produced parts, SUNON has
established four professional production facilities in the following locations : Kaohsiung, Taiwan; Foshan
(Guangdong), China; Kunshan (Jiangsu), China; and Beihai (Guangxi), China, Hefei (Anhui), China.
Europe
China / Foshan
China / Kunshan
Taiwan
Taiwan / Taipei
Japan/ Yokohama
U.S.A.
Research Center
Research Center
Research Center
Research Center
Research Center
Research Center
Research Center
England
Wolfeboro
SUNON SAS
San Jose
(Paris)
Beijing
Wuhan
SUNON INC
Shanghai
Shenzhen
(Yokohama, Japan)
(Los Angeles)
Austin
Taipei
Headquarters
(Kaohsiung, Taiwan)
Kaohsiung Plant
Foshan Plant
Kun Shan Plant
Beihai Plant
Hefei Plant
SUNON Eco DC Brushless Ventilation Fan
02
SUNON helps you
improve indoor air pollution
Today homes are built to be energy efficient for seal
heat and air-conditioning cost. However, these airtight
homes may actually cause health problems due to the
build-up of pollutants and uncirculated stale air. It may
have sealed in old, stale air, pollutants and excess
moisture inside as well. And all of which you’ll breathe
over and over again. In summertime, you're more
likely to close doors and windows to keep the heat out
and save on air-conditioning.
How can you have an airtight, energy efficient home
that's also healthy and well-ventilated?
SUNON’s DC motor technology, features energy
saving up to 60% compared to AC motor. With an
ultra-low power consumption of merely 10.5W, it
delivers an ultra-high air flow of 80 CFM. Save money
on your electricity bills up to 60% and save the
environment.
03
SUNON Eco DC Brushless Ventilation Fan
Builders’ smart choice for green construction
DC motor technology
Long Life
Harmony
on Sound
SUNON Eco Brushless Ventilation
Fans are engineered soft start
function to reduce the wear on
motor bearing and prolongs the
motor bearing’s life.
SUNON’s sound quality analysis
focuses not only the dBA but also
psychoacoustic analysis.
Energy
Saving
Energy
Efficiency
SUNON Eco Brushless
Ventilation Fans use 60% less
power than AC motor exhaust
fans.
SUNON Eco Brushless
Ventilation Fans are among the
most efficient ventilation fans
available, exceeding ENERGY
STAR requirements for efficiency.
SUNON
Ventilation Fan
Marketing
AC Fan
(BVA080M001)
Motor Type
AC motor
DC motor
Power Rating (V/Hz)
120 / 60
120 / 60
Static Pressure (Inch-H2O)
0.1
0.1
Air Flow (CFM)
80
80
Noise (Sones)
2.0
1.2
reduce 40%
Power Consumption (Watt)
26.1
10.5
reduce 60%
Energy Efficiency (CFM/Watt)
3.07
7.61
* following Energy Star V3.2 need to meet 2.8 CFM/W
** following Energy Star Most efficient 2014 need to meet 7.5 CFM/W
SUNON Eco DC Brushless Ventilation Fan
04
You should know-selection guide
About Energy Star
ENERGY STAR certified ventilation fans :
• provide better efficiency and comfort with less
noise.
• feature high performance motors and improved
ENERGY STAR : Conserv
Conserve energy and
blade design, providing better performance and
energy expenditures.
longer life.
Earning
the
ENERGY
STAR
means
products meet strict energy efficiency
guidelines set by the US Environmental
Protection Agency. Products that have
earned
the
ENERGY
STAR
deliver
exceptional features, while using less
energy. Saving energy helps you save
money on utility bills and protect our
As a ENERGY STAR partner, SUNON is committed to
environmental protection and strives to create
products meeting standards in energy star.
SUNON Eco DC Brushless Ventilation Fan features
high efficiency motors and lighting that can reduce
climate by helping prevent harmful carbon
energy consumption by as much as 80%—all without
pollution and reducing other greenhouse
sacrificing performance.
gases.
What is HVI
The Home Ventilating Institute (HVI) is an
independent organization that certifies the
• You are purchasing a product that has been tested
and certified to meet specific industry standards.
airflow and sound performance claimed by
• This product will perform as claimed.
manufacturers of ventilation products. HVI
• When installed correctly, you will enjoy proper
certification is your insurance that the air
ventilation that will maximize your indoor air quality.
flow (CFM rate) and noise level (sone) of
• The certified air flow and noise level ratings for the
our ventilation products were measured
ventilation equipment you have chosen have been
during rigorous testing conducted by an
determined through testing by an independent
independent laboratory. HVI certification is
laboratory.
your assurance that:
SUNON has approved Regular Membership by
Home Ventilating Institute (HVI).
05
SUNON Eco DC Brushless Ventilation Fan
What is sone
The amount of noise a fan makes is an important
consideration in choosing your fan. The industry
standard for measuring the amount of sound a fan
makes when it operates is called “sones”. One sone
is equivalent to the sound of quiet refrigerator. The
lower the sone rating, the quieter the fan will be. A
quiet bathroom fan will be rated at about 1.5 sones or
less.
What is CFM
CFM is the acronym for Cubic Feet per Minute—the
measure of air volume moved by the fan blower.
Choose a fan with a CFM rating appropriate for your
room size to ensure adequate ventilation.
The right choosing for ventilation fan
The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) sets the standard for residential
ventilation at a minimum of 0.35 air changes per hour, and not less than 15 cubic feet per minute (cfm) per person.
(ft2)
Use this simple formula or the chart to calculate
Bedrooms
Floor Area
the required CFM for continuous ventilation.
0-1
2-3
4-5
6-7
>7
<1500
30
45
60
75
90
1501-3000
45
60
75
90
105
3001-4500
60
75
90
105
120
4501-6000
75
90
105
120
135
5001-7500
90
105
120
135
150
7.5 x (3+1) = 30
>7500
105
120
135
150
165
Add together for a total of 60 CFM
CFM = .01 x floor area (in square feet) plus
7.5 x (number of bedrooms + 1).
Example: A 3,000 square foot home with
3 bedrooms would require 60 cfm:
.01 x 3,000 = 30
SUNON Eco DC Brushless Ventilation Fan
06
Elegant and all kinds of design.
You can have a variety of choices.
It’s a hidden ventilation fan!
07
SUNON Eco DC Brushless Ventilation Fan
Eco DC Brushless Ventilation Fan
Energy Saving
up to
Waterproof
60%
IPX5
Ventilation Fan
BVA080M001
BVA080M006
4
4
Power Rating (VAC)
110V-220V (50-60Hz)
110V-220V (50-60Hz)
Noise (Sones) @0.1Ps
1.2
1.0
model
Duct Dimensions (inch)
Static Pressure (Inch-H2O)
0.1
0.25
0.1
0.25
Air Flow (CFM)
80
69
80
69
10.5
12.5
10.5
12.5
Power Consumption (Watts)
※ Specifications in this catalog are preliminary specification for reference. Specifications are subject to change without notice.
Vantilation
Fan / LED Light
‧ CT 3000~3500K, 12W LED Light
model
BVA080M004
BVA080M003
BVA080M007
4
4
4
Power Rating (VAC)
110V-220V (50-60Hz)
110V-220V (50-60Hz)
110V-220V (50-60Hz)
Noise (Sones) @0.1Ps
1.0
1.0
1.0
Duct Dimensions (inch)
Static Pressure (Inch-H2O)
0.1
0.25
0.1
0.25
0.1
0.25
Air Flow (CFM)
80
69
80
69
42
35
10.5
12.5
10.5
12.5
7
8
Power Consumption (Watts)
※ Specifications in this catalog are preliminary specification for reference. Specifications are subject to change without notice.
Patent No.:ZL201320715356.4, ZL201320714973.2, ZL201330476885.9, ZL201330476884.4, ZL201330364650.0, ZL201420286641.3, ZL201420157902.1,
ZL201420310661.X, D162170, D161521, D162171
SUNON Eco DC Brushless Ventilation Fan
08
Flow2 One
Air Exchange System
IImprove IIndoor
d
Ai
Air Q
Quality
lit
Low Power
Consumption
4.6
W
09
Ultra-high
Air Flow
3M Filter
16.36 PM2.5
CFM
SUNON Eco DC Brushless Ventilation Fan
Filtration Efficiency 82%
Flow2 One Air Exchange System
In wintertime, you're more likely to close doors and windows to keep warm air and keep the cold air out. How
can you have an airtight, energy efficient home that's also healthy and well-ventilated? Flow2 One air exchange
system stands for single room ventilator. It is a technology to provide fresh air into a building, extract stale air
from the building. It can improve indoor air quality and you are always breathing in air that feels better.
Flow2 One is similar to a balanced ventilation system, it uses the heat in the outgoing stale air to warm up the
fresh air. A typical unit features two fans—one to take out household air and the other to bring in fresh air. What
makes an HRV unique is the heat-exchange core.
vent cap
fresh air in
outdoor temp.
14℉
Heat Removal
Efficiency
42%
Air-Conditioner
stale air out
36.7℉
14℉
68℉
3M PM2.5 Filter
What is Heat Recovery
Heat recovery is a process of continuously
preheating incoming cool supply air by warming it
Ø8.11
2.52
with the outgoing exhaust air. Warm air is not simply
Ø3.94
exhausted but transfers most of its heat to supply air
in a highly efficient heat recovery exchanger. At no
time do the airstreams mix as the heat radiates
through the plates of the exchanger.
Benefits and Features:
unit:inch
Flow2 One Air Exchange System
Specification
Mounting Dimensions (Duct size)
4"
Improve indoor air quality
Power Rating (V/Hz)
110-230 (50/60Hz)
Low power consumption 4.6W
Speed
high
low
Long life DC motor
Power Consumption (Watts)
4.6
3.7
42% heat recovery efficiency
Air Flow (CFM)
16.36
11.24
Through the wall mounted heat recovery unit
Noise (dB(A))
30.0
23.0
3M Filter PM 2.5 (Filtration Efficiency 82%)
Heat Removal Efficiency (%)
Efficient supply and exhaust single room ventilation
42%
※ Specifications are subject to change without notice. Product specifications are reference only.
Patent No.:
ZL201320621667.4, ZL201420214577.8, ZL201320627035.9, ZL201420214577.8, ZL201320627035.9
SUNON Eco DC Brushless Ventilation Fan
10