AirCycler®g2-k brochure here. - Green South Energy Solutions
Transcription
AirCycler®g2-k brochure here. - Green South Energy Solutions
AirCycler® g2-k Whole House Mechanical Ventilation System AirCycler® g2 Controller + FanConnect™ Switch + Fresh Air Damper The AirCycler® g2-k provides the most economical solution to whole-house mechanical ventilation by combining the best aspects of both central fan integrated ventilation and exhaust fan ventilation. How does the AirCycler® g2-k work? Anytime the home’s central fan is turned on by the thermostat to provide heating or cooling, the AirCycler® g2 opens the fresh air damper to let in a measured amount of fresh air. The fresh air is then distributed uniformly throughout the home. Once the ventilation requirements are met, the damper is closed to prevent over-ventilation. Should normal heating and cooling cycles not run long enough to provide the required ventilation, the AirCycler® g2 will power on the smaller and more economical exhaust fan, typically an existing bath fan, to provide the remaining ventilation. With no need to run the large central furnace to provide additional ventilation, homeowner complaints of cold air or noisy operation are eliminated and efficiency is drastically improved. EXAMPLE According to codes, you must add 30 CFM of continuous ventilation. You measure 90 CFM from the fresh air duct to the air handler. You measure 60 CFM exhausted from the bath fan. You can spend a lot of money on a HRV or ERV, or simply let the AirCycler® g2 use what you already have. • Direct replacement for the AirCycler® FRV ventilation controller. • Provides precise ventilation control for ultimate • Simple set-up with our patented new algorithm. • Works with any 24VAC damper. • Can control a 110VAC exhaust fan.* • Provides bath fan delay timer functions.* • Allows for programmable hours of operation. One Hour of Ventilation 0 minutes 15 minutes 30 minutes 60 minutes 45 minutes HRV/ERV System HRV/ERV at 30 CFM continuous for 60 minutes = 1,800 CF of fresh air VS Central Fan AirCycler® g2-k 90 CFM of fresh air during15 minutes of heating/cooling = 1,350 CF Exhaust Fan 60 CFM for 7.5 minutes 1,800 CF of fresh air required - 1,350 CF provided during heating/cooling = 450 CF still needed 450 CF / 60 CFM = 7.5 minutes of exhaust time required to meet the ventilation demand for that hour. ® www.aircycler.com *If used with the optional FanConnect™ switch This product may be protected by one or more of the following patents and patents pending: 8185244, 7258280, 6431268, 881806, 547017, Canada 2245135 TWO SETUP OPTIONS Calculated Flow If you know the amount of fresh air that goes into the air handler as well as the flow required by code, you can simply enter them into the AirCycler® g2 controller during set up. The g2 will do the rest. Calculated Time If you’d prefer to configure the amount of time you want fresh air ventilation per hour, you can enter the total minutes per hour into the AirCycler® g2. The g2 will do the rest. Calculated Flow Setup NORMAL OPERATION DISPLAY THE DAMPER IS OPEN THE EXHAUST FAN IS ON THE THERMOSTAT HAS TURNED ON THE CENTRAL FAN THE AIRCYCLER® G2 HAS FORCED THE FAN PERCENTAGE OF VENTILATION COMPLETE AirCycler® g2 Operating Voltage: 24 VAC (up to 30 VAC max) Calculated Time Setup Current Draw: 0.07 Amps Enter measured outside @HQƦNVSNSGD@HQG@MCKDQ Enter required minutes per GNTQNEUDMSHK@SHNM Enter measured DWG@TRSƦNV FanConnect™ Switch Light: 450 Watts @ 120 VAC (blue wire) *If connecting a FanConnect™ switch Enter required continuous @HQƦNVQDPTHQDCAXBNCD $MSDQLHMGNTQNEDWG@TRS UDMSHK@SHNMCDRHQDC Fan: 150 Watts @ 120 VAC (red wire) *If connecting a FanConnect™ switch Operation: 120 VAC ± 10% Enter optional mix time NO #NXNTV@MSSN RDSUDMSHK@SHNM GNTQR 2DSCDRHQDCGNTQR NENODQ@SHNM Set current time YES Part No. Description ACG2 AirCycler® g2 controller ACG2K-04 AirCycler® g2-k Whole-House Ventilation Kit with 4” Damper ACG2K-06 AirCycler® g2-k Whole-House Ventilation Kit with 6” Damper ACG2K-08 AirCycler® g2-k Whole-House Ventilation Kit with 8” Damper ACG2K-10 AirCycler® g2-k Whole-House Ventilation Kit with 10” Damper ACFCS FanConnect™ Switch $MSDQCDRHQDCCDK@XSHLD *If connecting a FanConnect™ switch END Begin normal operation