Accutrack AFTC 5 - ALSTOM Signaling Inc
Transcription
Accutrack AFTC 5 - ALSTOM Signaling Inc
ACCUTRACK PRODUCT SOLUTIONS ACCUTRACK PRODUCT SOLUTIONS AFTC5 AFTC5 Audio Frequency Track Circuit 5th Generation CONFIGURATION INFORMATION Configuration item Description Quantity AFTC5 subrack Enclosure, backplane, auxiliary boards and configuration keys 1–4 per customer’s 19-inch rack, as required TCU (Track Control Unit) module Enclosure, processor board, transceiver board, amplifier board 2–6 per AFTC5 subrack, as required (1 per field connection) PSU (Power Supply Unit) subrack Enclosure and backplane 1 per 2 AFTC5 subracks PSU module Enclosure and PSU board 1–4 per PSU subrack, as required SPECIFICATIONS AFTC5 is Alstom's next generation Audio Frequency Track Circuit for heavy rail and light rail transit applications MAIN FEATURES Functional / safety / reliability Electrical / mechanical Power supply 110VAC ±20% 47Hz to 63Hz MTBF 200,000 hours MTBHE greater than 109 hours Power factor greater than 95% MTTR less than 15 minutes Power consumption 115 W maximum per TCU AFTC5 subrack dimensions (including cables) in: 19 W x 10.5 H x 23.5 D cm: 48.3 W x 26.6 H x 59.7 D PSU subrack dimensions in: 19 W x 5.2 H x 11.9 D cm: 48.3 W x 13.3 H x 37.6 D Field connection cable length 5500 ft. maximum (longer if used with compensating capacitors) Compliance AREMA Yes CENELEC SIL 4 Yes •• Provides train detection, cab signaling and train-wayside communication •• Offers advanced maintenance capabilities •• Reduces costs and wiring AFTC5 The Alstom Advantage Meeting all market needs. AFTC5 is a highly configurable, jointless Audio Frequency Track Circuit. It is designed to operate between the interlocking and trackside AFTC equipment to vitally generate and receive rate-coded carrier for train detection and generate rate-coded carrier for speed commands to the train. Additionally, AFTC5 can generate and receive bidirectional non-vital train-wayside communication signals. AFTC5 eliminates the need for discrete wiring due to Ethernet communications with other AFTC5 units and interlocking processors. EASILY CONFIGURABLE — AT LOWER COST Parameters, such as frequencies, code rates, transmit/receive levels and IP addresses, are software configurable, allowing identical track circuit hardware to be used. AFTC5 reduces wiring costs using simple connections to the power supply, Ethernet, and trackside equipment. AFTC5 provides the clear advantages of accurate frequency transmission and reception and improved stability due to its digital signal processing capabilities. Environmental Operating temperature -40°F to 158°F -40°C to 70°C Storage temperature -67°F to 185°F -55°C to 85°C Vibration AREMA 11.5.1 Class C EMI/EMC AREMA 11.5.2 For more information please contact: abcd REMOTE DIAGNOSTICS Alstom’s Maintenance Management System (MMS) provides extensive diagnostic information for maintainers with remote or local access to perform preventive and corrective maintenance. MMS communicates with AFTC5 using Ethernet, collecting historic data measurements to determine overall track circuit health. AFTC5’s compact solution supports six track circuits in its 19-inch subrack. Typically four AFTC5 subracks can be mounted in a customer’s 19-inch rack, to support up to 24 track circuits. Phone: (800) 717-4477 P2531A. © 2015. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Alstom contributes to the protection of the environment. This leaflet is printed on environmentally friendly paper. AFTC5 supports installed Alstomcompatible trackside equipment and the wide range of customer-assigned frequency sets. AFTC5 Ethernet communication easily works with single and redundant interlocking processors. Signaling design is streamlined through the use of configurable AFTC5 modules and interlocking processors. COMPACT SIZE Alstom Signaling Inc. 1025 John Street West Henrietta, NY 14586 USA Visit us online: alstomsignalingsolutions.com FLEXIBILITY Example AFTC5 Subrack P2531A. © 2015. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Alstom contributes to the protection of the environment. This leaflet is printed on environmentally friendly paper. The power supply subrack(s), with either single or redundant power supplies, is included with the AFTC5 System. abcd ACCUTRACK PRODUCT SOLUTIONS AFTC5 APPLICATION DEVELOPMENT TOOL (ADT) Example Configuration Windows Signaling engineers use this application development tool to configure the AFTC5 system. ADT documents key technical features, capturing train detection, cab signaling, train-wayside communication, network and interfaced field equipment configuration data. Configuration data generated using ADT is flashed onto configuration keys used to program each TCU module. ADT supports efficient configuration when TCU modules require replacement and are reprogrammed using the configuration keys. Field Interface Example AFTC5 Subrack PSU PSU PSU PSU WZ-17 1NAAL T 1-3 1RABL PSU 1-3T Ethernet Switch Ethernet Switch 1RAAL PSU WZ-18 Auxiliary •• Up to eight train detection carrier frequencies, in the range of 1kHz–10kHz •• Up to three train detection code rates, in the range of 1.25Hz–27.5Hz •• Single code (same train detection and cab signal code rates) or dual code (different train detection and cab signal code rates) operation •• Train detection transmit/receive, transmit only, receive only or receive/receive •• Digital Signal Processing filters to ensure proper rejection of substation harmonics and other undesired signals •• Broken rail detection PSU Vital train detection PSU Ethernet Switch Ethernet Switch KEY TECHNICAL FEATURES Example Track Layout TCU TCU TCU TCU TCU Up to two cab signal carrier frequencies in the range of 990Hz–10kHz Up to 15 cab signal code rates, in the range of 1.25Hz–27.5Hz Code rate phase synchronization between adjacent track circuits Temporary speed restriction settable to any available code rate TCU •• •• •• •• Auxiliary Vital cab signals WZ-18 7X 1RAAL •• •• •• •• •• •• •• WEE-Z® (impedance) bonds Tuned loops—4-ft. Untuned loops—2-ft., 4-ft., long wire loop High-definition loops Terminating receivers Bridging receivers Train-wayside communication antennas 7R 1NAAL 5R WZ-17 1ABT 1RABL TCU TCU TCU TCU TCU MAINTENANCE MANAGEMENT SYSTEM (MMS) TCU Compatible field equipment Auxiliary Digital signal processing •• All signals are transmitted and received using Digital Signal Processing techniques, allowing for future upgrades of filters and modulation types 1AAT TCU TCU TCU TCU TCU TCU Auxiliary Non-vital train-wayside communication signals •• Frequency Shift Keying with 9650Hz ±150Hz or 9800Hz ±150Hz carrier frequencies •• Gross bit rate of 100 or 110 bits/s •• Manchester encoding, Return to Carrier encoding or no encoding 1X The MMS software application provides a graphical representation of AFTC5 system health indications and supports both local and remote module-level troubleshooting. Example Rack Configuration Example Maintenance Windows