ACCUTRACK PRODUCT SOLUTIONS
ACCUTRACK PRODUCT SOLUTIONS
AFTC5
AFTC5
Audio Frequency Track Circuit
5th Generation
CONFIGURATION INFORMATION
Configuration item
Description
Quantity
AFTC5 subrack
Enclosure, backplane, auxiliary boards and
configuration keys
1–4 per customer’s 19-inch rack, as required
TCU (Track Control Unit) module
Enclosure, processor board, transceiver board,
amplifier board
2–6 per AFTC5 subrack, as required
(1 per field connection)
PSU (Power Supply Unit) subrack
Enclosure and backplane
1 per 2 AFTC5 subracks
PSU module
Enclosure and PSU board
1–4 per PSU subrack, as required
SPECIFICATIONS
AFTC5 is Alstom's next
generation Audio
Frequency Track Circuit
for heavy rail and light rail
transit applications
MAIN FEATURES
Functional / safety / reliability
Electrical / mechanical
Power supply
110VAC ±20%
47Hz to 63Hz
MTBF
200,000 hours
MTBHE
greater than 109 hours
Power factor
greater than 95%
MTTR
less than 15 minutes
Power consumption
115 W maximum per TCU
AFTC5 subrack dimensions
(including cables)
in: 19 W x 10.5 H x 23.5 D
cm: 48.3 W x 26.6 H x 59.7 D
PSU subrack dimensions
in: 19 W x 5.2 H x 11.9 D
cm: 48.3 W x 13.3 H x 37.6 D
Field connection cable length
5500 ft. maximum (longer if used
with compensating capacitors)
Compliance
AREMA
Yes
CENELEC SIL 4
Yes
•• Provides train detection, cab
signaling and train-wayside
communication
•• Offers advanced
maintenance capabilities
•• Reduces costs and wiring
AFTC5 The Alstom Advantage
Meeting all market needs. AFTC5 is a highly configurable, jointless Audio
Frequency Track Circuit. It is designed to operate between the interlocking and trackside
AFTC equipment to vitally generate and receive rate-coded carrier for train detection and
generate rate-coded carrier for speed commands to the train.
Additionally, AFTC5 can generate and receive bidirectional non-vital train-wayside
communication signals. AFTC5 eliminates the need for discrete wiring due to Ethernet
communications with other AFTC5 units and interlocking processors.
EASILY CONFIGURABLE —
AT LOWER COST
Parameters, such as frequencies, code
rates, transmit/receive levels and IP
addresses, are software configurable,
allowing identical track circuit hardware
to be used. AFTC5 reduces wiring costs
using simple connections to the power
supply, Ethernet, and trackside equipment.
AFTC5 provides the clear advantages
of accurate frequency transmission and
reception and improved stability due to
its digital signal processing capabilities.
Environmental
Operating temperature
-40°F to 158°F
-40°C to 70°C
Storage temperature
-67°F to 185°F
-55°C to 85°C
Vibration
AREMA 11.5.1 Class C
EMI/EMC
AREMA 11.5.2
For more information
please contact:
abcd
REMOTE DIAGNOSTICS
Alstom’s Maintenance Management
System (MMS) provides extensive
diagnostic information for maintainers
with remote or local access to perform
preventive and corrective maintenance.
MMS communicates with AFTC5
using Ethernet, collecting historic
data measurements to determine
overall track circuit health.
AFTC5’s compact solution supports six
track circuits in its 19-inch subrack.
Typically four AFTC5 subracks can be
mounted in a customer’s 19-inch rack,
to support up to 24 track circuits.
Phone: (800) 717-4477
P2531A. © 2015. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or
correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to
change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Alstom contributes to the protection
of the environment. This leaflet is printed on environmentally friendly paper.
AFTC5 supports installed Alstomcompatible trackside equipment and
the wide range of customer-assigned
frequency sets. AFTC5 Ethernet
communication easily works with single
and redundant interlocking processors.
Signaling design is streamlined through
the use of configurable AFTC5 modules
and interlocking processors.
COMPACT SIZE
Alstom Signaling Inc.
1025 John Street
West Henrietta, NY 14586
USA
Visit us online:
alstomsignalingsolutions.com
FLEXIBILITY
Example AFTC5 Subrack
P2531A. © 2015. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or
correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to
change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Alstom contributes to the protection
of the environment. This leaflet is printed on environmentally friendly paper.
The power supply subrack(s), with either
single or redundant power supplies, is
included with the AFTC5 System.
abcd
ACCUTRACK PRODUCT SOLUTIONS
AFTC5
APPLICATION DEVELOPMENT
TOOL (ADT)
Example Configuration Windows
Signaling engineers use this
application development tool
to configure the AFTC5 system.
ADT documents key technical
features, capturing train detection,
cab signaling, train-wayside
communication, network and
interfaced field equipment
configuration data.
Configuration data generated
using ADT is flashed onto
configuration keys used to program
each TCU module. ADT supports
efficient configuration when TCU
modules require replacement
and are reprogrammed using the
configuration keys.
Field Interface
Example AFTC5 Subrack
PSU
PSU
PSU
PSU
WZ-17
1NAAL
T
1-3
1RABL
PSU
1-3T
Ethernet Switch
Ethernet Switch
1RAAL
PSU
WZ-18
Auxiliary
•• Up to eight train detection carrier frequencies, in the range of 1kHz–10kHz
•• Up to three train detection code rates, in the range of 1.25Hz–27.5Hz
•• Single code (same train detection and cab signal code rates) or dual code
(different train detection and cab signal code rates) operation
•• Train detection transmit/receive, transmit only, receive only or receive/receive
•• Digital Signal Processing filters to ensure proper rejection of substation
harmonics and other undesired signals
•• Broken rail detection
PSU
Vital train detection
PSU
Ethernet Switch
Ethernet Switch
KEY TECHNICAL FEATURES
Example Track Layout
TCU
TCU
TCU
TCU
TCU
Up to two cab signal carrier frequencies in the range of 990Hz–10kHz
Up to 15 cab signal code rates, in the range of 1.25Hz–27.5Hz
Code rate phase synchronization between adjacent track circuits
Temporary speed restriction settable to any available code rate
TCU
••
••
••
••
Auxiliary
Vital cab signals
WZ-18
7X
1RAAL
••
••
••
••
••
••
••
WEE-Z® (impedance) bonds
Tuned loops—4-ft.
Untuned loops—2-ft., 4-ft., long wire loop
High-definition loops
Terminating receivers
Bridging receivers
Train-wayside communication antennas
7R
1NAAL
5R
WZ-17
1ABT
1RABL
TCU
TCU
TCU
TCU
TCU
MAINTENANCE MANAGEMENT
SYSTEM (MMS)
TCU
Compatible field equipment
Auxiliary
Digital signal processing
•• All signals are transmitted and received using Digital Signal Processing techniques,
allowing for future upgrades of filters and modulation types
1AAT
TCU
TCU
TCU
TCU
TCU
TCU
Auxiliary
Non-vital train-wayside communication signals
•• Frequency Shift Keying with 9650Hz ±150Hz or 9800Hz ±150Hz carrier frequencies
•• Gross bit rate of 100 or 110 bits/s
•• Manchester encoding, Return to Carrier encoding or no encoding
1X
The MMS software application
provides a graphical representation
of AFTC5 system health indications
and supports both local and remote
module-level troubleshooting.
Example Rack Configuration
Example Maintenance Windows