NBC Air filter unit
Transcription
NBC Air filter unit
PRODUCTS > NBC Air Filtration Unit OUTSIDE 35 C HUMIDITY 90% 22º C Inside PROVIDED BY HEINEN & HOPMAN Heating Ventilation Air Conditioning Refrigeration INTRODUCTION Naval vessels have to operate now a day more and more under the threat of an attack by TIC’s and TIM’s. To be able to operate under these circumstances without being contaminated, reliable NBC filter systems are of the essence. With our NBC filter units, provided with STANAG4447 filter elements, in combination with our overpressure controllers, a safe operating environment (citadel) is created, ensuring the optimal performance of the crew and electronic equipment. Our NBC filter units are available in a capacity range of 900 up to 1800m3/h. APPLICATION Our nuclear, biological and chemical (NBC) filtration system provides clean filtered fresh air, free from NBC contaminates in an over pressure citadel. Three levels of filtration (coalescer, dust, and composite filtration) is applied to incoming air before being supplied to the citadel. The over pressure citadel removes the need for occupants to wear gas masks and protective clothing during NBC attacks. Two modes of operation allows clean fresh air to be supplied during peace time, or conventional combat times, and filtered fresh air during NBC warfare. The control system constantly compares inside and outside pressures, and should the citadel pressurization fail, provide a visual and/or audible warning. The NBC filter unit is designed for external installation to citadels with a supply duct to the citadel interior. The NBC control unit is designed to be installed internally within the citadel covering the air duct to diffuse air entering the citadel. When the NBC filter unit is operational the unit is designed as a fail-safe system, i.e. should the unit sustain damage or an air seal leak, then clean air will leak out of the unit rather than contaminated air being drawn in. KEY FEATURES • • • • • • • • • • • Unique innovative design; Smart and powerful NBC / TIM Filter clamping system; Easy service and maintenance access; Compact and lightweight; Completely closed system; Doors equipped with end switches Analyzed for gas tightness, shock, vibration and EMC; High shock resistance. Up to 60g vertical Design according NATO standard; Design according STANAG 4447; NBC Filter capacity 900, 1200 and 1800m³/h. FUNCTIONING AFU 1800 & AFU 1200 Technical Data AFU-1800 50Hz / 60Hz Air quantity 1.800m3/h Pst 1.000Pa Execution SS316L Filters 6pcs Power supply fan 3x380V-50Hz / 3x440V-60Hz Rated power 4.0kW / 4.8kW Power supply heater 3x380V-50Hz / 3x440V-60HZ Capacity 10kW Power supply valves 1x230V-50Hz / 1x230V-60Hz Weight (incl. NBC filters) 1.350kg Weight (excl. NBC filters) 1.170kg Control panel (separate delivery) 760x760x300mm Technical Data AFU-1200 50Hz / 60Hz Air quantity 1.200m3/h Pst 1.000Pa Execution SS316L Filters 4pcs Power supply fan 3x380V-50Hz / 3x440V-60Hz Rated power 4.0kW / 4.8kW Power supply heater 3x380V-50Hz / 3x440V-60HZ Capacity 10.5kW Power supply valves 1x230V-50Hz / 1x230V-60Hz Weight (incl. NBC filters) 1.350kg Weight (excl. NBC filters) 1.170kg Control panel (separate delivery) 760x760x300mm AFU 900 Technical Data AFU-900 50Hz / 60Hz Air quantity 900m3/h Pst 1.000Pa Execution SS316L Filters 3pcs Power supply fan 3x380V-50Hz / 3x440V-60Hz Rated power 2.6kW / 3.12kW Power supply heater 3x380V-50Hz / 3x440V-60HZ Capacity 10.5kW Power supply valves 1x230V-50Hz / 1x230V-60Hz Weight (incl. NBC filters) 900kg Weight (excl. NBC filters) 810kg Control panel (separate delivery) 760x760x300mm Alternatives available on request. Owing to continued product development Heinen Hopman reserves the right to introduce alternations without prior notice. Brazil T: +55 21 3587 4241/4244 E: [email protected] France T: +33 (0)6 3090 7786 E: [email protected] Germany T:+49 40 73 1680 E: [email protected] India T: +91 33 6499 1293 E: [email protected] Italy T: +39 0187 457970 E: [email protected] The Netherlands (HQ) T: +31 (0)33 299 2500 E: [email protected] The Netherlands (Rotterdam) T: +31 (0)78 890 8050 E: [email protected] Peoples Republic of China T: +86 21 32 53 28 96 E: [email protected] Romania T: +40 236 448 222 E: [email protected] Russia T: +7 (4012) 308 801 E: [email protected] Singapore T: +65 6897 7879 E: [email protected] Spain T: +34 93 225 96 68 E: [email protected] South Korea T: +82 (0)70 4901 0000 E: [email protected] Turkey T: +90 216 493 8118 E: [email protected] USA (Fort Lauderdale, Florida) T: +1 954 463 0110 E: [email protected] USA (Houma, Louisiana) T: +1 800 294 2653 E: [email protected] UAE (Dubai) T: +971 (0)50 624 2961 E: [email protected] UAE (Abu Dhabi) T:+971 (0)2 550 4147 E: [email protected] Heinen & Hopman encourages a more sustainable world. By providing eco-friendly solutions and services we offer our clients the option of reducing energy consumption and thus CO2 emissions. Visit greenmanifest.info for more information. www.heinenhopman.com