Large Surface and Suspension Installation

Transcription

Large Surface and Suspension Installation
SURFACE MULTIFORMS
SURFACE AND SUSPENSION MOUNT
INSTALLATION INSTRUCTIONS
Warnings:
* Risk of fire or electric shock.
* Disconnect all power before installing or servicing.
* Installation Instructions for qualified electricians only.
* Install per National Electrical Code and local regulations.
* Read Installation Instructions completely before installation.
* Failure to follow Installation Instructions may void warranties.
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
®
C
US
Page 1 of 2
PREPARE FIXTURE:
1. Remove LAMP FRAME from Housing by pulling straight out. The frame is
locked into place via 4 ball catch retainers See Fig 1.
Fixture
Housing
Ball Catch
Studs
ELECTRICAL CONNECTION:
The housing features an easy access WIRING ENCLOSURE for simplified field
wiring installation.
Ball Catch
Retainers
DO NOT modify the factory wiring settings as it may cause the luminaire to
malfunction. Provide electrical service, according to the “National Electrical
Code” or your local electrical code.
Gimbal / Lamp Frame
Notes: Review fixture labeling to make sure it is rated for the voltage installation being used. Make sure no bare wires are exposed outside the wire nut
connectors.
INSTALLATION: (*2 MOUNTING OPTIONS)
1. REMOVE THE ELECTRICAL ACCESS panel from the inside at
the top of the housing. See Fig 1
*2.Junction Box Mounting - Knock out center location at top
of housing / mounting bracket. SECURELY FASTEN HOUSING
to MOUNTING SURFACE with applicable hardware and connect
power supply lines to quick disconnects provided.
Mounting
Surface
Junction
Box
*3. Suspension Cable Mounting - Designed for optional
SUSPENDED CABLE system, cables provided for convenience.
See SMH Suspended series instruction sheet (attached).
4. FEED POWER SUPPLY line thru the access panel and
RE-ATTACH PANEL.
Electrical Compartment
Access Panel
5. REMOVE LAMP RETAINING RING from gimbal, set lamp into
gimbal assembly, carefully SECURE LAMP WITH RETAINING RING
AND CONNECT SOCKET.
6. ATTACH POWER SUPPLY line to lamp sockets and SLIDE
LAMP/GIMBAL FRAME INTO HOUSING.
7. Reattach LAMP/GIMBAL FRAME by pushing frame into
housing and firmly snap into ball catch receivers.
Ball Catch
Retainers
Fixture
Housing
Mounting
Screws
Ball Catch
Studs
Lamp / Gimbal Frame
FIGURE 1
©2015 LF ILLUMINATION LLC
HEADQUARTERS
Telephone: 818-885-1335
We reserve the right to change or
9200 Deering Avenue
Toll Free: 855-885-1335
withdraw specifications without prior notice.
Chatsworth CA 91311
Fax: 818-576-1335
www.lfillumination.com
rev: 030515
SURFACE MULTIFORMS
SUSPENSION MOUNT & HARDWARE
INSTALLATION INSTRUCTIONS
Warnings:
NOTE: ALL WORK MUST BE DONE WITH CIRCUIT OFF AND FRAME SHOULD NOT BE INSTALLED WHEN
FIXTURE IS ENERGIZED. READ ALL CAUTIONS ON PAGE 1
Pre-Installation Preparation
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
1. Screw Toggle Nut in place on 1/4 - 20 Screw using several turns. See Fig 2.
2. Make 3/4 inch diameter hole through Ceiling. See Fig 2.
Page 2 of 2
FIXTURE MOUNTING:
1. Measure desired vertical height of ceiling to fixture.
2. Cut loose end of Cable to measured ceiling to fixture height.
3. Depress Griplock Glider Device Plunger and insert loose end of Cable
into Griplock Glider Device.
4. Release Plunger to secure Cable and tighten plunger cap. See Fig 4.
NOTE:
To shorten fixture height after installation, depress Plunger on Griplock
Glider Device, remove Cable, cut Cable to new length and reinsert into
Griplock Glider Device.
3/4”
1/4 - 20
Toggle Bolt
1/16” Cable
Toggle Nut
Cable
Coupler
Closed
Toggle Nut
Ceiling
Coupler
Ceiling
Coupler
FIGURE 1
Pre-Installed
Griplock Glider
Device
Ceiling
Lighting Fixture Housing
FIGURE 2
FIGURE 4
ELECTRICAL CONNECTION:
J-box (octagonal box recommended, provided by others.)
5” diameter steel canopy with power feed outlet and cable connector provided.
HARDWARE MOUNTING:
1. Press Toggle Nut Closed and slide through 3/4 inch hole in Ceiling.
See Fig 2.
2. With Toggle Nut Expanded tighten Cable Coupler until Ceiling stays tight
between Toggle Nut and Cable Coupler. See Fig 3.
3. Screw Ceiling Coupler Cable Assembly onto screw. See Fig 3.
DO NOT modify the factory wiring settings as it may cause the luminaire to
malfunction. Provide electrical service, according to the “National Electrical
Code” or your local electrical code, from a suitable junction box (octagonal
junction box recommended).
Make sure no bare wires are exposed and canopy, cable mounting is set
securely in place.
Mounting
Surface
Junction
Box
Power Supply
with J-Box Canopy
Toggle Nut
Cable Grip Hardware
1 @ Each Corner
(4 places)
Ceiling / Cable
Coupler Assembly
Ceiling
1/16” Cable
Electrical Compartment
Access Panel
Ball Catch
Retainers
FIGURE 3
Fixture
Housing
Mounting
Screws
Ball Catch
Studs
Lamp / Gimbal Frame
©2015 LF ILLUMINATION LLC
HEADQUARTERS
Telephone: 818-885-1335
We reserve the right to change or
9200 Deering Avenue
Toll Free: 855-885-1335
withdraw specifications without prior notice.
Chatsworth CA 91311
Fax: 818-576-1335
www.lfillumination.com
030515