Manual and assembly instructions Replacing RSU90 limit switch unit
Transcription
Manual and assembly instructions Replacing RSU90 limit switch unit
Manual and assembly instructions Replacing RSU90 limit switch unit RW241 Motor Gearboxes 1-phase\230V\50Hz Ridder Drive Systems Lorentzstraat 36-38 䡩 3846 AX Harderwijk P.O. Box 360 䡩 3840 AJ Harderwijk The Netherlands T +31 (0)341 416 854 䡩 F +31 (0)341 416 611 E [email protected] 䡩 I www.ridder.com 265097EN - V01 - 201012 Contents Scope of RW-RSU manual and assembly instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warnings contained in the manual and assembly instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Conditions for internal switching on the power supply of RW241 motor gearboxes . . . . . . . . . . . . 3 General warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Wiring diagram symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 RW241 motor gearbox wiring diagram: 230V\50Hz\1~\RC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 RSU limit switch system replacement instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Adjusting the RSU limit switch system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Rotational directions of RW241 motor gearboxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Scope of RW-RSU manual and assembly instructions The manual and assembly instructions contain important information for installers for replacing and operating the RSU limit switch unit of the Ridder 1-phase RW241 motor gearbox. Please read the manual and instructions before replacing the RSU limit switch unit. All work must be carried out by qualified and licensed mechanical and/or electrical installers under safe and responsible conditions. Warnings contained in the manual and assembly instructions This manual contains tips, observations and warnings of various types and degrees. Below is a list and description of the meaning of a tip, observation or warning. TIP A suggestion or advice in respect of carrying out an operation. WARNING Remarks and extra information regarding potential problems arising when an operation is carried out incorrectly. CAUTION The product or system may become damaged when an operation is carried out incorrectly. DANGER The user or installer could suffer physical and/or life-threatening injury when an operation is carried out incorrectly. Ridder Drive Systems 2010.12 䡩 T +31 (0)341 416 854 䡩 2 F +31 (0)341 416 611 䡩 I www.ridder.com Conditions for internal switching on the power supply of RW241 motor gearboxes The RSU limit switch system of a Ridder 1-phase RW241 motor gearbox can be used to switch on the power supply of the 1-phase electric motor, provided the following conditions are met: r RSU limit switch unit 501102 (230, 1-phase, >60mA); r 1-phase, 220-230V power supply; r Maximum 1.2A motor current; r RC circuits are applied with the RSU working switches (250V, 0.033mF0.1mF, 100W); r The neutral conductor (N) of the power supply must be connected via the safety switches of the RSU limit switch unit. Failure to meet the conditions for switching on the power supply of the RSU limit switch system may cause system damage and/or create hazardous situations. DANGER General warnings DANGER Disconnect the power supply before performing (maintenance) work on the RW241 motor gearbox or the driven system. CAUTION Parallel connecting of 2 or more RW motor gearboxes with 1-phase electric motors is not allowed! CAUTION Wait two seconds after operating a RW motor gearbox before driving it in the opposite direction. Wiring diagram symbols Symbol EM ES11, ES12 ES21, ES22 K11, K21 L1, N, PE Q11 RC Description Electric motor RSU limit switch system duty switches RSU limit switch system safety switches Reverse switching relay Phase, Neutral, Earth Motor safety switch RC circuit Ridder Drive Systems 2010.12 䡩 T +31 (0)341 416 854 䡩 3 F +31 (0)341 416 611 䡩 I www.ridder.com RW241 motor gearbox wiring diagram: 230V\50Hz\1~\RC Before switching on the power supply of the RW241 motor gearbox of the RSU limit switch system, check that the wiring is connected according to the following wiring diagram. The RC circuits must be connected to the contacts of the duty switches of the RSU limit switch system (as shown in the RSU box). Cables may not be connected to the RSU limit switch system as shown in the RSU , RSU and RSU boxes. PE N L1 Q11 K22 EM K21 RSU PE 1 RC PE W1 U1 12 V1 10 11 9 RC 7 8 6 4 5 3 1 2 L2 M 1~ L1 ES22 C ES12 ES21 ES11 B A PE RSU PE RSU N 2 N 3 12 11 10 9 ES22 8 7 ES12 B 6 5 4 3 ES21 2 1 12 ES11 10 9 ES22 䡩 8 7 ES12 B A Ridder Drive Systems 2010.12 11 6 5 4 3 ES21 2 RSU PE 4 12 1 11 10 9 ES22 ES11 8 7 ES12 T +31 (0)341 416 854 䡩 4 F +31 (0)341 416 611 5 4 3 ES21 2 1 ES11 A B A 6 䡩 I www.ridder.com RSU limit switch system replacement instructions These instructions describe how to replace the RSU limit switch system of the RW241 motor gearbox and how to connect the RSU limit switch system for switching on the power supply of the 1-phase electric motor of the RW241 motor gearbox. 1 Switch off the power supply before replacing the RSU limit switch system of a Ridder RW motor gearbox! DANGER The following tools are required for replacing the RSU limit switch system: 2 - Screwdriver - Star screwdriver - Side cutter pliers The following replacement set is required for replacing the RSU limit switch system: - 501107 RSU90-230\1\>60mA\RC SET 3 This set includes a manual, an RSU limit switch system, two RC circuits and a connection wire. 4 The RSU limit switch system is located under the limit switch cover of the RW241 motor gearbox (white border). 5 Take the limit switch cover off the RW241 motor gearbox by removing the 4 screws holding it in place. Ridder Drive Systems 2010.12 䡩 T +31 (0)341 416 854 䡩 5 F +31 (0)341 416 611 䡩 I www.ridder.com Position the new RSU limit switch system near the RSU limit switch system to be replaced. 6 U1 W1 N L2 L1 V1 RSU RC 12 11 10 9 8 W1 1 RC 7 6 5 4 L2 3 2 V1 1 Now transfer the wiring from the first RSU limit switch system to the new one. Connect the wiring to the RSU as shown in the RSU diagram. L1 RSU 2 12 11 0 10 9 8 7 6 5 4 3 2 1 If the wiring is initially connected as shown in the RSU or RSU diagrams, make wiring connections as shown in the RSU diagram. 7 W1 L2 V1 L1 RSU RS 3 12 11 10 0 U1 9 8 W1 7 6 5 4 N L2 3 2 1 L1 V1 RSU RS 4 12 11 0 10 9 8 7 6 5 4 3 2 1 If, however, wiring is initially connected as shown in the RSU diagram, you will not need to change anything. Depending on the connection situation, follow the instructions provided in 7A for RSU , instructions in 7B for RSU , and instructions 7C for RSU . Transfer and connect the wiring as follows: RSU 7A 2 rL1 from 1 to 1 (existing RSU to new RSU); rL2 from 7 to 7; rV1 from 3 to 3 (or W1 from 3 to 3, depending on direction of rotation of electric motor); rW1 from 9 to 9 (or V1 from 9 to 9); rConnect N to clamp 4 (new RSU); rConnect U1 to clamp 12; rConnect jumper wire (supplied) to clamps 6 and 10. RSU 1 Proceed to step 8. Ridder Drive Systems 2010.12 䡩 T +31 (0)341 416 854 䡩 6 F +31 (0)341 416 611 䡩 I www.ridder.com Transfer and connect the wiring as follows: RSU 7B 3 rL1 from 1 to 1 (existing RSU to new RSU); rL2 from 7 to 7; rV1 from 6 to 3 (or W1 from 6 to 3, depending on direction of rotation of electric motor); rW1 from 12 to 9 (or V1 from 12 to 9); rConnect N to clamp 4 (new RSU); rConnect U1 to clamp 12; rConnect jumper wire (supplied) to clamps 6 and 10. r(Wires between 3-4 and 9-10 are not used) RSU 1 Proceed to step 8. Transfer and connect the wiring as follows: RSU 7C 4 rL1 from 1 to 1 (existing RSU to new RSU); rL2 from 7 to 7; rV1 from 3 to 3 (or W1 from 3 to 3, depending on direction of rotation of electric motor); rW1 from 9 to 9 (or V1 from 9 to 9); rN from 4 to 4; rU1 from 12 to 12; rConnect jumper wire (supplied) to clamps 6 and 10. RSU 1 Proceed to step 8. Remove the existing RSU switch system by loosening the two fastening screws (screws are located under the opening at the top of the RSU switch system). 8 CAUTION Mount the new, wired RSU limit switch system on the RW motor gearbox. Attention! When mounting the limit switch system, make sure that the long set screws of the limit switch system do not touch the switch spring arms of microswitches and the RSU limit switch system. 9 Now secure the RSU limit switch to the gear housing by tightening the screws. Ridder Drive Systems 2010.12 䡩 T +31 (0)341 416 854 䡩 7 F +31 (0)341 416 611 䡩 I www.ridder.com 12 mm 10 After connecting and installing the new RSU limit switch system, connect the RC circuits. But first cut the connecting wires of the RC circuits down to about 12 mm. 11 Mount the first RC circuit on the clamping strip of the RSU limit switch system on clamps 1 and 3. 12 Mount the second RC circuit on the clamping strip of the RSU limit switch system on clamps 7 and 9. Replacement of the RSU limit switch system is now complete. 13 Check that the RSU limit switch system is functioning properly by driving the RW motor gearboxes in both end positions. WARNING To readjust the limit switch system, follow the instructions for “Adjusting the RSU limit switch system”. Mount the limit switch cover of the RW241 motor gearbox and tighten the 4 screws that hold it in place. 14 Ridder Drive Systems 2010.12 䡩 T +31 (0)341 416 854 䡩 8 F +31 (0)341 416 611 䡩 I www.ridder.com Adjusting the RSU limit switch system ES11 B ES21 A a 12 11 10 6 b A B A 4 2 3 9 8 7 6 5 4 3 2 1 b a C NC NO C NC NO C NC NO C NC NO 7 7 3 2 4 1 6 B ES22 ES12 ES21 ES11 ES12 ES22 RSU limit switch system installation The following describes the steps for adjusting the RSU limit switch system of the RW motor gearbox. Current and voltage range The contacts in the switches for the Ridder RSU limit switch system can be connected to the following currents: r 24V-AC, currents 60 mA to 130 mA; r 230V, current to 1.2 A. Ridder RSU limit switch system The Ridder RSU limit switch system is a linear switch system, specifically designed for use in RW motor gearboxes. The limit switch system is driven by the output shaft of the motor gearbox via a secondary transmission. The number of revolutions of the output shaft can be set between a starting and ending position. The maximum range equates to 86 revolutions of the output shaft. Delivery The RSU limit switch system will not have been adjusted on delivery. The adjusting rings (3) can be moved freely round the milled nuts (2). This means that the range of the drive in both rotational directions is not limited and also prevents a switch system failure due to outside operation. How it works The main shaft of the motor gearbox drives the wire shaft (1) of the RSU limit switch system via a secondary transmission. When running, the switch followers (4) will move along the threaded shaft as it rotates. The friction between the threaded shaft and the switch follower pushes the setscrew (a) lightly against one of the two switch springs (which one it will be depends on the direction of rotation). When a switch follower reaches the end of the threaded shaft, it will change its linear motion and rotate with the threaded shaft. The setscrew (a) then pushes against the switch spring, causing it to deflect and trip a duty switch (ES11 or ES12). This in turn causes a signal that activates the relay, stopping the motor gearbox. Should a relay or duty switch fail, then a safety switch (ES21 or ES22) will also be tripped by the switch spring. This causes a signal that activates a safety relay, stopping the controller and also thereby the motor gearbox. This prevents consequential damage to the system. Ridder Drive Systems 2010.12 䡩 T +31 (0)341 416 854 䡩 9 F +31 (0)341 416 611 䡩 I www.ridder.com Connection When connecting the Ridder RSU limit switch system, please refer to the wiring diagrams provided for this purpose. Setting The end positions are set as follows: r Rotate the main shaft of the motor gear box system to bring the system to the end position (completely open or completely closed) and determine which duty switch (ES11 or ES12) should be tripped. r The milled nut (2) can easily be screwed by hand along the threaded shaft (1). The switch follower (4) also moves along the threaded shaft. Turn the milled nut on the appropriate side, “hand tight” up to the stop (7). r Now rotate the adjusting ring (3) over the milled nut just far enough to trip the duty switch. r Then fasten the adjusting ring with setscrews (a and b) firmly on the milled nut. The adjusting ring can no longer be rotated over the milled nut. Repeat the previous steps to adjust the limit switch system for the opposite direction of rotation. WARNING Always check the operation of the limit switch system after setting the two end positions! CAUTION Always prevent overrunning of the adjusted limits when operating the motor gearbox manually (with hexagon in the electric motor). This will damage the limit switch system! Rotational directions of RW241 motor gearbox B A A B A B A B Ridder Drive Systems 2010.12 䡩 T +31 (0)341 416 854 䡩 10 F +31 (0)341 416 611 䡩 I www.ridder.com Ridder Drive Systems 2010.12 䡩 T +31 (0)341 416 854 䡩 11 F +31 (0)341 416 611 䡩 I www.ridder.com