CENTER WALL W/
WINDOW MULLION
A
225
226
A
223
CENTER WALL W/
WINDOW MULLION
A
220
A
D31
CENTER WALL W/
WINDOW MULLION
218
219
D34
D35
D36
D27
229
210
STD. WATER FOUNTAIN ( P-3)
NO WORK IN THIS AREA
206
CAP PLUMBING
BEHIND WALL &
REPAIR WALL.
D03
D38
A
NO WORK IN THIS AREA
EXCEPT FOR NEW CASED
OPENING AS NOTED.
A
RELOCATE WATER
FOUNTAINS TO HERE.
212
D04
D44
D43
D42
NEW 3'W. x 7'H. CASED OPENING.
LOCATE BASED ON EXISTING
SYSTEMS FURNITURE AND AWAY
FROM DOOR D04 AS POSSIBLE.
EXISTING 1-HR FIRE RATED
CORRIDOR TO REMAIN
D41
D39
216
SEVENTH & FRANKLIN BUILDING
701 EAST FRANKLIN STREET SUITE 1115
RICHMOND, VIRGINIA 23219-2510
( 804) 783-9800
( 804) 783-9801 FAX
[email protected]
2'-0"
PROVIDE 30"x48"
ACCESSIBLE CLEARANCE
@HANDICAP WATER
FOUNTAIN ( P-2) .
221
224
207
3'-6"
D29
228
202
D02
D37
215
D28
208
201
NEW PLAM WALL & BASE
CABINETS & NEW SINK
( P-1) -SEE DETAILS 1/A4.
222
D30
209
213
D01
A
ALIGN
227
200
214
A
D33
WALL HEIGHT TO BE EXTENDED
FOR GPDW CEILING IN 213.
ALIGN W/
EDGE OF
MULLION
A
A
D32
CENTER WALL W/
WINDOW MULLION
211
7'-1"
A
CENTER WALL W/
WINDOW MULLION
D40
230
252
217
D26
D09
TENANT
MODIFICATIONS
FOR
204
231
203
251
232
NO WORK IN THIS AREA
243
242
D18
D14
D17
241
239
245
D05
D11
NO WORK IN THIS AREA
EXCEPT FOR NEW DOOR.
EXISTING 1-HR FIRE RATED
CORRIDOR TO REMAIN
D16
D13
246
244
5211 W. BROAD STREET
HENRICO, VIRGINIA
249
248
D15
EXISTING 1-HR FIRE RATED
CORRIDOR TO REMAIN
233
S U ITE 200
D10
D25
D24
LU MBER
LIQUIDATORS
205
D12
247
D19
D08
D23
NO WORK IN THIS AREA
D06A
12'-11"
234
D20
A
18'-8"
236
A
237
D21
NO WORK IN THIS AREA
EXCEPT FOR NEW DOOR.
D07
238
ER
C
235
250
D06B
TI
C
T
240
D22
FIE
I
D A RCH
TE
SCALE: 1/8" = 1'-0"
PROJECT NO: 2418.02
PARTITION PLAN
SCALE: 1/8" = 1'-0"
P ARTITION LEG END:
NOTE: CONTRACTOR TO VERIFY EXISTING WALLS AND
MODIFY AS NECESSARY.
EXISTING WALLS
TO BE REMOVED.
EXISTING WALLS TO REMAIN.
A
NEW BLDG. STD. FULL HEIGHT WALLS TO UNDERSIDE
OF ACOUSTICAL CEILING OR GPDW CEILING U.N.O..
1/2" GPDW ON BOTH SIDES OF 3 5/8" METAL STUDS @
24" O.C. W/ 3" ACOUSTICAL INSULATION BETWEEN.
CONTRACTOR TO PROVIDE WALL BRACING USING
METAL STUD ANGLE BRACING SPACED @ 8' O.C. MAX,
ALTERNATING SIDES & ATTACHED USING PARTITION
CLIPS AT SUSPENDED CEILING CONNECTION AND
ANCHORED TO BUILDING STRUCTURE ABOVE.
EXISTING DOOR TO BE REMOVED.
REFERENCE NORTH
DEMOLITIO N NO TES:
1. CONTRACTOR TO REMOVAL ALL WALLS AS NOTED BY DOUBLE
DASHED LINES INCLUDING REMOVAL OF ALL DOORS, FRAMES,
AND ALL ELECTRICAL OUTLETS/COMMUNICATION OUTLETS IN
DEMOLISHED WALLS & ALL OTHER SUSPENDED CEILING
REWORK AND OTHER ITEMS AS INDICATED ON PLANS FOR
COMPLETION OF NEW CONSTRUCTION WORK.
2. REMOVE LIGHT FIXTURES, AND OTHER ITEMS AS NOTED AND
AS NEEDED FOR THE INTENT OF THE DRAWINGS. COORDINATE
ALL DEMOLITION WORK WITH TENANT'S NEEDS AND
DIRECTIONS.
3. CONTRACTOR TO REMOVE ALL EXISTING CARPET, VINYL
COMPOSITION TILE, VINYL BASE IN AREA OF WORK. SEE SCOPE
OF NEW WORK.
NEW C O NS TRU C TION NOTES :
1. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND
CONDITIONS. IF DIFFERENT CONDITIONS EXIST, CONTRACTOR
SHALL NOTIFY ARCHITECT BEFORE COMMENCING WORK.
2. SEE PARTITION/DOOR LEGEND FOR GENERAL INTENDED
CONSTRUCTION WORK. WORK SHALL CONSIST OF ENTIRE
CONSTRUCTION WORK AS DETAILED WITH THESE CONSTRUCTION
DOCUMENTS UNLESS OTHERWISE AMENDED IN WRITING BY THE
ARCHITECT.
3. DIMENSIONS TAKE PRECENDENCE OVER SCALE ON
CONSTRUCTION DOCUMENTS. DIMENSIONS ARE TAKEN TO THE
FACE OF PARTITIONS UNLESS OTHERWISE NOTED.
4. ALL CONSTRUCTION AND TENANT IMPROVEMENTS SHALL BE IN
STRICT ACCORDANCE WITH THE CURRENT APPROVED EDITIONS
OF THE UNIFORM STATEWIDE BUILDING CODE; AND ANY
AMENDMENTS REQUIRED BY THE LOCAL JURISDICTION; AND
APPROVED BY THE LOCAL BUILDING INSPECTION OFFICE.
EXISTING DOOR TO REMAIN.
( SEE DOOR SCHEDULE)
5. SEE DOOR SCHEDULE & NOTES. - SEE DOOR SCHEDULE AND
NOTES.
NEW BLDG STD. F.R. DOOR ( 3'0"W. )
TO BE INSTALLED WITH BLDG STD. LEVER HARDWARE.
( SEE DOOR SCHEDULE)
6. CONTRACTOR TO FURNISH AND INSTALL ALL INTERIOR FINISHES
IN ALL NEW AREAS OF WORK. SEE FINISH NOTES FOR ORDERING
INFORMATION. SEE FINISH AND ROOM SCHEDULES AND NOTES.
7. ALL ELECTRICAL WORK AND COMMUNICATION OUTLETS &
WIREWAYS SHALL BE PERFORMED BY THE CONTRACTOR.
COMMUNICATION WIRING AND FINAL TERMINATIONS SHALL BE
PROVIDED BY THE TENANT'S VENDOR. ANY EXISTING
COMMUNICATION WIRING NOT TO BE RE-USED SHALL BE REMOVED
FROM SPACE INCLUDING ABOVE CEILING SPACES. COORDINATE
WIRING DEMOLITION WITH NEW TENANT'S VENDOR PRIOR TO
REMOVAL.
8. CONTRACTOR TO INSTALL NEW PLASTIC LAMINATE WALL &
BASE CABINETS AS INDICATED.
9. CONTRACTOR TO MODIFY EXISTING BLDG. STANDARD MECHANICAL
HVAC SYSTEMS TO PROVIDE UNIFORM COVERAGE AND
DISTRIBUTION IN ALL SPACES AND AS REQUIRED BY CODE.
CONTRACTOR TO EXTEND EXISTING DUCTWORK AND INSTALL NEW
RETURN AIR AND SUPPLY AIR GRILLES AS REQUIRED DUE TO WALL
CHANGES IN THE SPACE.
10. SEE REFLECTED CEILING WORK. ALL FIXTURES, DIFFUSERS,
OUTLETS, AND OTHER CEILING MOUNTED DEVICES SHALL BE
INSTALLED AS NOTED.
11. CONTRACTOR TO FABRICATE NEW OCCUPANCY SIGNS WITH
PERMANENT SIGNAGE ( ENGRAVED AND/OR VINYL LETTERS) AND
INSTALL ADJACENT TO EACH ENTRY DOOR ( APPROX 12"x12") FOR
CLASSROOMS & ASSEMBLY AREAS 224, 231, 237, 240-250, & 251
INDICATING MAXIMUM NUMBER OF PERSONS FOR EACH SPACE. SEE
BUILDING CODE INFORMATION FOR EACH MAXIMUM OCCUPANCY.
B UILDING CO DE INFORMATION:
BUILDING CODE: VA. REHABILITATION CODE - LEVEL 2 ALTERATION
ICC 2012 W/ VA. STATE AMENDMENTS)
USE GROUP CLASSIFICATION - B BUSINESS
TYPE OF CONSTRUCTION - IIB
FIRE PROTECTION: NON-SPRINKLERED
REQUIRED FIRE SEPARATION: 0 HR. - FLOOR/CEILING
2 HR. - FIRE STAIRS - TWO-STORY
2 HR. - SHAFTS - TWO-STORY
1 HR. - CORRIDORS( SERVES >30)
0 HR. - TENANT SEPARATION
EGRESS-
P RO J EC T C ONTACTS :
TENANT CONTACT:
JOE MACCARONE
LUMBER LIQUIDATORS - DIR. OF CONST.
5211 W. BROAD ST, SUITE 200
RICHMOND, VIRGINIA 23230
( 757) 778-9672
CONTRACTOR:
CORINNA GROGAN / JOHN GENTRY
DOMINION CONSTRUCTION PARTNERS
1840 WEST BROAD STREET, SUITE 300
RICHMOND, VIRGINIA 23220
( 804) 249-2600 ( OFFICE)
[email protected]
[email protected]
< 75' MAX. COMMON PATH OF EGRESS
< 200' MAX. EXIT ACCESS TRAVEL DISTANCE
BUSINESS OCCUPANCY LOAD ( NEW & EXISTING TENANT SPACE) :
NEW 14,600 SF/100 SF ( B-USE)
=146 PERSONS
EXISTING 5615 SF/100 SF ( B-USE) = 57 PERSONS
CONF. RM./ASSEMBLY OCCUPANCY USE:
CONF. RM. 224:
350 SF/20 SF ( TABLE/CHAIRS)
= 18 PERSONS
CONF. RM. 231:
385 SF/20 SF ( TABLE/CHAIRS)
= 20 PERSONS
CONF. RM. 237:
200 SF/20 SF ( TABLE/CHAIRS )
= 10 PERSONS
CONF. RM./ASSEMBLY 240 & 250 COMBINED:
1150 SF/7 SF ( CHAIRS )
= 165 PERSONS
CONF. RM. 251:
590 SF/20 SF ( TABLE/CHAIRS)
= 40 PERSONS
AREA OF
WORK
BLDG. OWNER CONTACT: TERRY COOPER
BERNSTEIN ENTERPRISES
5206 MARKEL DRIVE SUITE 306
RICHMOND, VIRGINIA 23230
( 804) 288-1232
> 50 PERSONS
( W/ 2 MEANS OF EGRESS)
FLOOR LOADS: 75 PSF ( LIVE LOAD)
DATE: 24 MARCH 2015
ARCHITECT:
RICHARD COMESS, AIA
ARCHITECTURAL & INTERIOR SERVICES
701 E. FRANKLIN ST, SUITE 1115
RICHMOND, VIRGINIA 23219
( 804) 783-9800 ( OFFICE)
[email protected]
5211 W. BROAD ST.
1
KEY P LAN
REFERENCE NORTH
C ONS TRU CTION
P LAN
SHEET:
A1
OF
2
N
N
225
223
N
N
N
N
214
220
219
218
N
N
N
N
S
S
N
S
S
N
210
S
215
SEVENTH & FRANKLIN BUILDING
701 EAST FRANKLIN STREET SUITE 1115
RICHMOND, VIRGINIA 23219-2510
( 804) 783-9800
( 804) 783-9801 FAX
[email protected]
207
206
EM
EM
221
229
212
224
EM
EM
228
201
N
N
222
227
202
208
EXTEND EXIST.
CEILING TO MATCH
EXIST. GPDW. CLG.
S
S
209
213
N
N
N
200
EM
EM
EM
211
216
230
252
217
EM
226
N
EM
N
TENANT
MODIFICATIONS
FOR
EM
N
231
204
N
203
251
LU MBER
LIQUIDATORS
N
EM
N
232
EM
S U ITE 200
EM
5211 W. BROAD STREET
HENRICO, VIRGINIA
242
243
248
249
205
EM
EM
241
233
239
246
EM
247
EM
EM
N
236
EM
S
250
237
ER
T
C
S
N
N
C
T
N
240
EM
EM
N
235
244
EM
EM
EM
234
EM
245
IF
238
I ED A RCH I
TE
SCALE: 1/8" = 1'-0"
REFLEC TED C EILING PLAN
DATE: 24 MARCH 2015
SCALE: 1/8" = 1'-0"
REFERENCE NORTH
C EILING P LAN LEGEND:
LIG HT F IXTURES
VERIFY ALL EXISTING CONDITIONS.
NEW AND/OR EXISTING 2'x4' RECESSED/SURFACE FIXTURE
TO MATCH BLDG. STD. FIXTURES NOTED "N" INDICATES
NEW LIGHT FIXTURE AND/OR LOCATION.
CONTRACTOR TO VERIFY COUNTS & ADD NEW FIXTURES
AS REQUIRED.
S
WALL SWITCH - BLDG. STD. - 48" AF CONTROLS LIGHT
FIXTURE( S) IN SAME SPACE UNLESS OTHERWISE
NOTED. PROVIDE MOTION SENSOR SWITCHING OPTION.
AREA OF
WORK
HVAC LEGEND:
CONTRACTOR TO RE-USE EXISTING CEILING
SUPPLY & RETURN GRILLES AND MODIFY AND EXTEND
DUCTWORK AND GRILLE LOCATIONS TO PROVIDE
UNIFORM AIR DISTRIBUTION TO ALL SPACES.
T
EMERG ENC Y & EXIT FIXTURES
EM
NEW EMERGENCY LIGHT FIXTURE ( EITHER WALL
AND/OR CEILING MOUNTED TIED INTO THE
BUILDING EMERGENCY CIRCUIT AS
REQUIRED TO PROVIDE 1 FOOTCANDLE
IN EGRESS EXITWAY PATH. REPLACE ALL EXIST.
FIXTURES W/ NEW LED EMERGENCY FIXTURES. SEE
ELECTRICAL/COMMUNICATION PLAN - DWG. A3 FOR
REQUIRED PATH OF EGRESS. FIXTURE SPACING MAY
DIFFER TO INDICATED FIXTURE SPACING BASED ON
FIXTURE TYPE.
1.
CONTRACTOR TO REWORK EXISTING CEILING GRID, CEILING
TILES, LIGHT FIXTURE PLACEMENT AND SUPPLY/RETURN AIR
DUCTWORK AS REQUIRED DUE TO NEW WALL CHANGES AND TO
PROVIDE UNIFORM COVERAGE TO ALL SPACES. ALL REWORKED
CEILINGS GRIDS, ACOUSTICAL CEILING TILES AND DRYWALL
CEILINGS SHALL BE CLEAN AND PROVIDE UNIFORM AND NEW-LIKE
APPEARANCE IN ALL SPACES. ALL EXISTING LIGHT FIXTURES
SHALL BE CLEANED AND RELAMPED WITH( 4100 K. LAMPS) U.N.O.
AND NEW LIGHT FIXTURES SHALL MATCH TO EXISTING.
2.
MODIFY EXISTING BLDG. STANDARD MECHANICAL HVAC TO
PROVIDE UNIFORM COVERAGE AND DISTRIBUTION AS REQUIRED
BY CODE. ALL EXISTING AIR DIFFUSERS AND/OR RETURN AIR
GRILLES SHALL BE CLEANED.
CONTRACTOR TO RELOCATE THERMOSTAT TO
PROVIDE BALANCED HVAC TO ALL SPACES.
NEW THERMOSTAT LOCATION TO BE LOCATED BY
HVAC CONTRACTOR. NOT ALL LOCATIONS SHOWN ON
PLANS WITH CONTRACTOR TO VERIFY. SEE ELECTRICAL/
COMMUNICATION PLANS FOR INDICATED LOCATIONS.
P ATH OF EGRES S
NEW EXIT SIGN - BUILDING STANDARD EXIT SIGN.
CEILING MOUNTED.
PROVIDE NEW LED EXIT SIGNS W/ EMERGENCY
BATTERY AS INDICATED FOR NEW FIXTURES.
REFLEC TED C EILING NOTES :
PATH OF EGRESS SHOWN BY DASHED LINE. SEE
DWG A3 FOR PATHWAY AND DIRECTION.
5211 W. BROAD ST.
1
PROJECT NO: 2418.02
KEY P LAN
REFERENCE NORTH
REF LECTED
C EILING PLAN
SHEET:
A2
OF
4
COORDINATE OUTLET LOCATIONS
W/ CASEWORK - SEE ELEVATIONS.
200
d +46"AF
225
226
223
220
218
219
214
213
d +30"AF
gfi& d
+46"AF
209
202
208
201
gfi& d
+46"AF
222
227
PP
PP
d
d FOR PTR.
228
229
212
221
224
206
207
210
215
SEVENTH & FRANKLIN BUILDING
701 EAST FRANKLIN STREET SUITE 1115
RICHMOND, VIRGINIA 23219-2510
( 804) 783-9800
( 804) 783-9801 FAX
[email protected]
216
230
PP
211
252
217
PP
PP
PP
d FOR PTR.
232
TENANT
MODIFICATIONS
FOR
204
d FOR PTR.
PP
231
203
251
PP
LU MBER
LIQUIDATORS
PP
S U ITE 200
3'-8"
MIN.
PP
242
243
248
5211 W. BROAD STREET
HENRICO, VIRGINIA
249
PP
245
PP
205
COPIER
233
239
d
PTR.
d
241
246
244
247
PP
234
240
PP
237
ER
T
C
T
C
235
236
250
IF
238
I ED ARCH I
TE
SCALE: 1/8" = 1'-0"
SCALE: 1/8" = 1'-0"
DATE: 24 MARCH 2015
ARROWS INDICATE ACCESSIBLE PATH OF EGRESS
IN SPACE. VCC - SECTION 1007
REFERENCE NORTH
AREA OF
WORK
ELECTRICAL AND
C OMMU NICATION LEGEND:
GENERAL NOTES: CONTRACTOR TO PROVIDE ALL
ELECTRICAL WORK AND TEL/COMM. WALL CONDUIT AND
JUNCTION BOXES RECESSED IN WALLS ONLY U.N.O.
TENANT TO PROVIDE ALL TEL/COMM. WIRING ( CAT 6) , &
FINAL TERMINATIONS & TEL/COMM. OUTLETS.
CONTRACTOR TO REMOVE ALL EXISTING COMM. WIRING
NOT TO BE RE-USED ( COORDINATE WITH TENANT'S
VENDOR) AND ALL ELEC./COMM. DEVICES IN WALLS TO
BE REMOVED.
ELEC TRICAL AND
C OMMU NICATION NOTES:
ELEC TRICAL:
1.
2.
3.
4.
EXISTING DUPLEX ELECTRICAL
RECEPTACLE WALL MOUNTED
d
gfi
NEW DUPLEX ELECTRICAL
RECEPTACLE WALL MOUNTED
DEDICATED ELEC. CIRCUIT ( 20 AMP)
GROUND FAULT PROTECTION
NEW TELEPHONE/COMMUNICATION ( DATA)
OUTLET WALL MOUNTED
PP
POWER POLE TO CONNECT SYSTEMS FURNITURE
WITH POWER & COMMUNICATION WIRING.
CONTRACTOR TO PROVIDE JUNCTION BOX ABOVE CEILING AND
CONNECT POWER TO TENANT FURNISHED POWER POLES.
VERIFY POWER REQUIREMENT/CIRCUITS.
5211 W. BROAD ST.
1
ELEC TRIC AL & C OMMU NICATION PLAN
PROJECT NO: 2418.02
ALL RECEPTACLES SHALL BE MOUNTED MIN. OF 18" ABOVE FINISHED
FLOOR WITH BUILDING STANDARD RECEPTACLE COVERS UNLESS
OTHERWISE NOTED.
PATCH WALL WHERE ANY WALL MOUNTED OUTLETS ARE REMOVED.
CONTRACTOR SHALL REVIEW WITH TENANT LOCATIONS, INSTALLATION
AND TYPES OF ELECTRICAL AND COMMUNICATION OUTLETS AND
CONDUIT/JUNCTION BOX SIZES REQUIRED AS WELL AS RESPONSIBILITIES
OF WORK TO BE PERFORMED BY TENANT AND CONTRACTOR.
CONTRACTOR SHALL PERFORM ALL REQUIRED ENGINEERING REQUIRED
TO PROPERLY CIRCUIT AND RUN ALL CABLING IN ACCORDANCE WITH THE
NEC, GOOD ENGINEERING PRACTICES AND LOCAL ORDINANCES HAVING
JURISDICTION. ALL NEW WORK SHALL MATCH BUILDING STANDARD
ELECTRICAL WORK PRESENTLY IN PLACE WITH EQUAL OR BETTER MEANS
AND METHODS.
C OMMU NIC ATION:
1.
2.
3.
CONTRACTOR TO FURNISH AND INSTALL WALL OUTLET BOX WITH PULL
STRING TO CEILING PLENUM ABOVE. TENANT TO PROVIDE CABLING AND
FINAL CONNECTIONS.
CONTRACTOR TO PROVIDE BLDG. STD. COVER PLATES FOR ALL UN-USED
BOXES.
CONTRACTOR SHALL REMOVE ALL EXISTING WIRING NOT TO BE REUSED.
KEY P LAN
REFERENCE NORTH
ELECT/ COMMU N.
P LAN
SHEET:
A3
OF
4
NO
NEW/EX.
MATL
WIDTH
H.M.
WD.
3'-0"
HEIGHT
THICK
HAR DWAR E S C HEDU LE:
FIN
HDW
FTYPE
FMATL
FFIN
REMARKS
-
-
B.S.
-
H.M.
HM
-
EXISTING FIRE STAIR DOOR TO REMAIN "AS-IS"
-
7'-0"
7'-0"
1 3/4"
7'-0"
-
-
-
-
HM
-
WD.
3'-0"
7'-0"
1 3/4"
STN
LS#2
B.S.
HM
-
EXISTING ELEVATOR DOORS - NO CHANGE
MATCH TYPE & FINISHES TO EXISTING DOOR D02.
WD.
3'-0"
7'-0"
PS#1
B.S.
HM
PT-2
-
WD.
WD
7'-0"
7'-0"
1 3/4"
1 3/4"
1 3/4"
PT-2
3'-0"
3'-0"
PT-2
PT-2
PS#1
PS#1
B.S.
B.S.
H.M.
H.M.
PT-2
PT-2
-ADD LITE KIT TO EXISTING DOOR.
EXIST C
WD
3-0"
7'-0"
1 3/4"
PT-2
LS#4
B.S.
HM
PT-2
ADD NEW PANIC HARDWARE & 8" x 30" LITE KITE.
EXIST C
EXIST A
WD
3'-0"
7'-0"
1 3/4"
PT-2
LS#4
B.S.
HM
PT-2
WD
3'-0"
7'-0"
1 3/4"
PT-2
LS#3
B.S.
HM
PT-2
ADD NEW PANIC HARDWARE & 8" x 30" LITE KITE.
-
WD
3'-0"
7'-0"
PS#1
B.S.
HM
-
ADD LITE KIT TO EXISTING DOOR.
WD
3'-0"
PT-2
LS#1
D12
WD
3-0"
1 3/4"
PT-2
LS#1
B.S.
B.S.
H.M.
HM
PT-2
PT-2
ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR.
EXIST B
7'-0"
7'-0"
1 3/4"
1 3/4"
PT-2
D11
EXIST C
EXIST B
D13
EXIST B
EXIST B
EXIST B
WD
7'-0"
1 3/4"
PT-2
LS#1
B.S.
HM
PT-2
ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR.
WD
3'-0"
3'-0"
LS#1
LS#1
HM
B.S.
HM
PT-2
PT-2
ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR.
1 3/4"
1 3/4"
PT-2
PT-2
B.S.
3'-0"
7'-0"
7'-0"
1 3/4"
WD
B.S.
B.S.
H.M.
HM
PT-2
PT-2
ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR.
B.S.
HM
PT-2
ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR.
EXIST EX.
D02
EXIST EX.
D03
H.M.
D04
EXIST EX.
NEW
C
D05
NEW
D06A
D06B
EXIST. C
NEW
C
D07
D08
D10
D14
D15
C
PR. 3-0"
1 3/4"
D16
EXIST B
WD
3'-0"
7'-0"
PT-2
LS#1
D17
EXIST B
WD
3-0"
7'-0"
1 3/4"
PT-2
D18
WD
1 3/4"
PT-2
WD
3'-0"
3'-0"
7'-0"
D19
EXIST B
EXIST C
LS#1
LS#1
D20
EXIST -
H.M.
3'-0"
D21
NEW
D22
EXIST B
WD
WD
D23
EXIST B
EXIST B
WD
D24
D25
D26
EXIST C
EXIST. A
WD
D27
D28
EXIST B
EXIST C
EXIST B
D29
D30
D31
C
WD
WD
WD
WD
WD
PT-2
PS#1
B.S.
HM
PT-2
PT-2
LS#4
B.S.
HM
PT-2
VERIFY PROPER OPERATION OF EXISTING EGRESS DOOR.
3'-0"
PS#1
3-0"
7'-0"
PT-2
LS#1
B.S.
B.S.
H.M.
HM
PT-2
PT-2
-
1 3/4"
PT-2
3'-0"
3'-0"
7'-0"
1 3/4"
PT-2
LS#1
B.S.
HM
PT-2
7'-0"
1 3/4"
PT-2
LS#1
B.S.
HM
PT-2
ADD NEW LITE KIT TO EXIST. DOOR.
ADD NEW LITE KIT TO EXIST. DOOR.
3'-0"
3'-0"
7'-0"
7'-0"
PT-2
PS#1
LS#1
7'-0"
7'-0"
B.S.
B.S.
B.S.
HM
H.M.
HM
PT-2
3-0"
3'-0"
3'-0"
1 3/4"
1 3/4"
1 3/4"
B.S.
HM
PT-2
3'-0"
3'-0"
3'-0"
7'-0"
7'-0"
D32
D33
3'-0"
7'-0"
D34
D35
NEW
NEW
B
B
WD
WD
3'-0"
3-0"
7'-0"
7'-0"
D36
D37
NEW
NEW
B
B
WD
WD
3'-0"
3'-0"
7'-0"
7'-0"
D38
D39
EXIST A
EXIST A
WD
3'-0"
3'-0"
7'-0"
D40
D41
D42
NEW
B
EXIST A
EXIST A
D43
D44
EXIST A
EXIST A
WD
3-0"
3'-0"
3'-0"
WD
WD
3'-0"
3'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
1 3/4"
PT-2
PT-2
1 3/4"
1 3/4"
1 3/4"
PT-2
LS#1
B.S.
HM
PT-2
PT-2
LS#1
LS#1
B.S.
B.S.
HM
HM
PT-2
PT-2
PT-2
1 3/4"
1 3/4"
1 3/4"
1 3/4"
PT-2
PT-2
LS#1
LS#1
B.S.
B.S.
HM
HM
PT-2
PT-2
PT-2
PT-2
LS#1
LS#1
B.S.
B.S.
H.M.
HM
PT-2
PT-2
1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
PT-2
PT-2
LS#1
LS#1
B.S.
B.S.
HM
HM
PT-2
LS#1
LS#1
B.S.
B.S.
B.S.
HM
H.M.
HM
PT-2
PT-2
PT-2
B.S.
1 3/4"
1 3/4"
1 3/4"
1 3/4"
PT-2
PT-2
PT-2
LS#3
LS#3
PT-2
PT-2
PT-2
VERIFY PROPER OPERATION OF EXIST. DOOR.
VERIFY PROPER OPERATION OF EXIST. DOOR.
VERIFY PROPER OPERATION OF EXIST. DOOR.
-
B.S.
B.S.
HM
HM
24"x30"
LITE KIT
( F.R. AS
INDICATED
ON SCHEDULE)
-
A
STANDARD DOOR
B.S. WOOD
DOOR IN HM FRAME.
B.S. WOOD
DOOR IN HM FRAME.
ADD NEW LITE KIT TO EXIST. DOOR.
-
-
PT-2
PT-2
B.S. WOOD
DOOR IN HM FRAME.
ADD NEW LITE KIT TO EXIST. DOOR.
PT-2
HM
DOOR & WI NDOW TYPES:
ADD NEW LITE KIT TO EXIST. DOOR.
ADD NEW LITE KIT TO EXIST. DOOR.
ADD NEW LITE KIT TO EXIST. DOOR.
HM
B.S.
LS#3 - BUILDING STANDARD CLOSET DOOR LOCK SET.
CLOSET FUNCTION, B.S. HINGES, DOOR STOP.
ADD NEW LITE KIT TO EXIST. DOOR.
-
-
LS#2 - BUILDING STANDARD ENTRY DOOR LOCK SET -ENTRANCE
DOOR LOCK W/ INSIDE ALWAYS FREE, B.S. DOOR
CLOSER, B.S. 1 1/2 PAIR HINGES, DOOR STOP
COORDINATE DOOR HARDWARE WITH TENANT CONTROLLED
ACCESS DEVICES.
LS#4 - NEW PANIC PUSHBAR RELEASE FROM INSIDE OF SPACE.
WITH LEVER LATCHSET ON OUTSIDE. INSIDE ALWAYS FREE,
B.S. 1 1/2 PAIR HINGES, B.S. DOOR STOP.
RELOCATED DOOR, ADD 24" x 30" LITE KIT.
PT-2
PT-2
PT-2
LS#1 - BUILDING STANDARD OFFICE DOOR LOCK SET
RM. LOCKSET. OFFICE FUNCTION, INSIDE ALWAYS FREE,
B.S. HINGES, DOOR STOP.
SEVENTH & FRANKLIN BUILDING
701 EAST FRANKLIN STREET SUITE 1115
RICHMOND, VIRGINIA 23219-2510
( 804) 783-9800
( 804) 783-9801 FAX
[email protected]
ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR.
1 3/4"
1 3/4"
WD
WD
WD
WD
WD
ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR.
1 3/4"
LS#1
PS#1
PS#1 - BUILDING STANDARD ( B.S.) PASSAGE SET B.S. LEVER HARDWARE, B.S. DOOR HINGES, B.S. WALL
MOUNTED ( U.N.O.) DOOR STOP
ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR.
7'-0"
7'-0"
7'-0"
PT-2
PT-2
PT-2
CONTRACTOR SHALL COORDINATE ALL DOOR HARDWARE TO
MATCH EXISTING TENANT HARDWARE AND FUNCTION.
COORDINATE ALL CONTROLLED ACCESS DEVICES AND LOCKS
WITH TENANT PRIOR TO HARDWARE ORDER.
-
ADD NEW PANIC HARDWARE & 8" x 30" LITE KITE.
EXIST B
EXIST B
NEW
B
NEW
B
WD
WD
EXISTING TENANT ENTRY DOORS TO REMAIN "AS-IS"
NOTES: CONTRACTOR TO RE-USE & MATCH TO EXISTING
BUILDING STANDARD DOORS, H.M. FRAMES & LEVER HARDWARE
WHERE POSSIBLE. SEE DOOR SCHEDULE. NEW HARDWARE TO
MATCH EXISTING . CONTRACTOR TO PROVIDE FINAL TOUCH-UP
OF ALL DOORS TO PROVIDE NEW-LIKE APPEARANCE.
43" MAX AF
D01
D09
ROOM S C HEDULE
TYPE
DOOR S C HEDU LE
8"x30"
LITE KIT
43" MAX AF
FINIS H S C HEDU LE
B
OFFICE DOOR
C
CONFERENCE ROOM DOOR
TENANT
MODIFICATIONS
FOR
LU MBER
LIQUIDATORS
S U ITE 200
5211 W. BROAD STREET
HENRICO, VIRGINIA
3/4" THK SHELVES
( MEL-1 FINISH)
W/ ADJ. BRACKETS
PLAM FINISHED END
BUTCHER BLOCK
COUNTERTOP. - TENANT
FURNISHED; CONTRACTOR
INSTALLED.
PLAM FINISHED END
DEDICATED ELEC.
OUTLET @46"A.F.
DEDICATED & GFI ELEC.
OUTLET @46"A.F.
MICROWAVE SHELF
18" D x 1 1/2" THK.) &
RECESSED AREA.
( UPPER & LOWER)
ADA SINGLE
BOWL SINK P-1
DEDICATED & GFI ELEC.
OUTLET @46"A.F.
DEDICATED ELEC.
OUTLET @30"A.F.
TENANT
FURNISHED
REFRIGERATOR
TENANT
FURNISHED
VENDING
MACHINE
CONTRACTOR
FURNISHED
WATER CONNECTIONSVERIFY NUMBER REQ'D.
PLAM FINISHED END
3/4" THK SHELVES
( MEL-1 FINISH)
W/ ADJ. BRACKETS
ER
T
INSULATED
PIPES
C
T
C
FULL EXTENSION
DRAWERS ( MEL-1)
IF
I ED ARCH I
TE
OPEN
SCALE: 1/8" = 1'-0"
PROJECT NO: 2418.02
1.
1.
3.
4.
5.
ALL SPACES IN AREAS OF WORK SHALL RECEIVE NEW FINISHES
UNLESS OTHERWISE NOTED. SEE FINISH AND ROOM SCHEDULES.
OPTION WORK MAY INCLUDE UPDATED FINISHES IN MENS TOILET
ROOM, AND NEW LOBBY FLOORING.
CONTRACTOR SHALL FOLLOW MANUFACTURER'S REQUIREMENTS
FOR PROPER INSTALLATION OF ALL FINISHES AS SCHEDULED.
FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR SURFACE
PREPARATION. REPAIR ALL EXISTING SURFACES TO PROVIDE
SMOOTH AND STRAIGHT SURFACES TO RECEIVE NEW FINISHES.
REPAIRS SHALL INCLUDE PATCHING AND LEVELING OF FLOOR
SURFACES AND DRYWALL .
CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD MEASURING & ALL
CALCULATIONS FOR MATERIAL QUANTITY NEEDED AND RECEIVING
AND INSPECTION FOR FLAWS. CONTRACTOR IS RESPONSIBLE FOR
CLEAN-UP OF ALL FINISH MATERIALS WITH FINISHES TO BE CLEAN
AND FREE OF MARKS, LOOSE THREADS AND OTHER IMPERFECTIONS.
PROVIDE ALL TRANSITION STRIPS MEETING ACCESSIBLE
STANDARDS AND MATCHING MATERIALS & FINISH JOINING CARPET
AREAS I.E. WOOD TRANSITION STRIP AT WOOD/CARPET
TRANSITION, AND/OR OTHER SIMILIAR MATERIALS WHERE
APPLICABLE.
CONTRACTOR SHALL RETURN ALL SURPLUS PAINT, CARPET & BASE
OVER TO TENANT FOR LATER REPAIRS/ REPLACEMENT.
1
DATE: 24 MARCH 2015
SCALE: 1/2" = 1'-0"
C AS EWORK NO TES :
AREA OF
WORK
PLU MB ING FIXTURE S C HEDULE
5211 W. BROAD ST.
FINIS H NO TES :
NEW WALL & BAS E C AB INETS &
C OU NTERTOP W/ NEW S INK IN AREA 213
1. ALL PLASTIC LAMINATE CASEWORK ITEMS SHALL BE FABRICATED IN
STRICT ACCORDANCE WITH AWI SECTION 400 CUSTOM GRADE WITH
FLUSH OVERLAY CONSTRUCTION W/ PLASTIC LAMINATE EXPOSED
SURFACES. SEE FINISH SCHEDULE FOR FINISH SELECTIONS.
2. CONTRACTOR TO PROVIDE SURFACE WOOD BLOCKING AS REQUIRED
TO PROVIDE PROPER SUPPORT OF WALL HUNG CASEWORK.
BRACE WALLS TO STRUCTURE ABOVE AS REQUIRED.
CONTRACTOR SHALL PROVIDE AND INSTALL PLUMBING FIXTURES AS INDICATED
AND PROVIDE ANY ADDITIONAL ASSEMBLIES INCLUDING DRAIN,
STRAINER, STOP, BACK-FLOW PREVENTER, ETC. TO PROVIDE A COMPLETE
FIXTURE INSTALLATION.
SEE PLUMBING FIXTURE SCHEDULE FOR NEW SINK & PROVIDE NEW
WATER CONNECTIONS FOR ICE MAKER IN REFRIGERATOR ( TENANT FURNISHED)
APPLIANCES AND WATER CONNECTIONS FOR VENDING MACHINES AS NEEDED.
3. THE SINK SHALL COMPLY WITH ICC A117.1-2009 FOR ACCESSIBILITY.
MODIFICATIONS SHALL BE MADE TO PROVIDE FULL COMPLIANCE.
P LU MBING NOTES :
1. CONTRACTOR SHALL COORDINATE ALL WORK WITH ARCHITECTURAL DRAWING,
EXISTING PLUMBING LINES, & PROPOSED FIXTURES & NEW WALLS PRIOR
TO ROUGH-IN PLUMBING FIXTURES AND CAPPING/RE-CONFIG. EXISTING LINES.
2. TRENCHING, INSUALTION AND BACK-FILLING FOR PIPING AND MAINTAINING PROPER
SLOPE PIPE SIZING & PROVIDING APPROVED ENGINEERED DRAWINGS OF ALL
PLUMBING WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
3. ALL PIPING SHALL BE CONCEALED IN WALLS AND ANY MAIN
WATER CUT-OFFS OR CONTROLS IN WALLS WILL BE ACCESSED
THRU FLUSH ACCESS DOORS.
KEY P LAN
REFERENCE NORTH
S C HEDU LES &
DETAILS
SHEET:
A4
OF
4