berita acara pemberian penjelasan pengadaan alat laboratorium
Transcription
berita acara pemberian penjelasan pengadaan alat laboratorium
BERITA ACARA PEMBERIAN PENJELASAN PENGADAAN ALAT LABORATORIUM STANDARISASI, KALIBRASI DAN INSTRUMENTASI UPTD METROLOGI Nomor Tanggal Lampiran : 027/02/001-ALATLAB.METRO/IV/2015 : 21 April 2015 : 26 (dua puluh enam) lembar Pada hari ini Selasa tanggal Dua Puluh Satu Bulan April Tahun Dua Ribu Lima Belas bertempat di Unit Layanan Pengadaan Provinsi Kalimantan Timur Jl. Gajah Mada No 2 Samarinda, kami selaku Pokja Pengadaan Alat Laboratorium Standarisasi, Kalibrasi dan Instrumentasi UPTD.Metrologi, telah mengadakan Rapat Pemberian Penjelasan secara Online di Website http://spse.kaltimprov.go.id, dengan rincian paket sebagai berikut: Nama Paket : Pengadaan Alat Laboratorium Standarisasi, Kalibrasi dan Instrumentasi UPTD.Metrologi Nilai HPS : Rp 2.781.796.600,Sumber Dana : APBD Provinsi Kaltim Tahun Anggaran 2015 HAL - HAL YANG DISAMPAIKAN : I. Pemberian penjelasan dibuka tanggal 21 April 2015 Pukul 13.00 WITA dan ditutup Pukul 15.30 WITA; II. Hadir Dalam Rapat Online : 1) Kuasa Pengguna Anggaran (KPA) Pengadaan Alat Laboratorium Standarisasi, Kalibrasi dan Instrumentasi UPTD.Metrologi; 2) Pejabat Pelaksana Teknis Kegiatan (PPTK) Pengadaan Alat Laboratorium Standarisasi, Kalibrasi dan Instrumentasi UPTD.Metrologi; 3) Pokja Pengadaan Alat Laboratorium Standarisasi, Kalibrasi dan Instrumentasi UPTD.Metrologi. III. Hasil Penjelasan : Sampai dengan berakhirnya Pemberian Penjelasan Paket Pekerjaan Pengadaan Alat Laboratorium Standarisasi, Kalibrasi dan Instrumentasi UPTD.Metrologi ada 15 (lima belas) pertanyaan yang disampaikan oleh rekanan. (copy penjelasan secara online terlampir). Demikian Berita Acara ini dibuat pada tanggal, bulan, tahun di atas dan merupakan satu kesatuan yang tak terpisahkan dengan Dokumen Lelang. Samarinda, 21 April 2015 POKJA PENGADAAN ALAT LABORATORIUM STANDARISASI, KALIBRASI DAN INSTRUMENTASI UPTD.METROLOGI Ttd LAMPIRAN BA. PEMBERIAN PENJELASAN I. PERTANYAAN PENYEDIA & TANGGAPAN PANITIA *Keterangan : Ada 15 pertanyaan dan sudah ditanggapi oleh Pokja ULP. II. RAB DAN SPESIFIKASI TERLAMPIR III. PENYESUAIAN PERSYARATAN KUALIFIKASI SEMULA : 1) Peserta Yang Berbadan Usaha Harus Memiliki Surat Ijin Usaha Perdagangan (SIUP) Kode 47726, Perdagangan Eceran Alat Laboratorium, Farmasi Dan Kesehatan; 2) Peserta Yang Berbadan Usaha Harus Memiliki pengalaman pada subbidang Perdagangan Eceran Alat Laboratorium, Farmasi Dan Kesehatan; 3) Peserta Yang Ber Berbadan Usaha HarusMemiliki tenaga ahli/teknis/terampil dengan kualifikasi keahlian sebagaimana spesifikasi teknis; MENJADI : 1) Peserta Yang Berbadan Usaha Harus Memiliki Surat Ijin Usaha Perdagangan (SIUP) Kode 47726, Perdagangan Eceran Alat Laboratorium, Farmasi Dan Kesehatan; 2) Peserta Yang Berbadan Usaha Harus Memiliki pengalaman pada subbidang Perdagangan Eceran Alat Laboratorium, Farmasi Dan Kesehatan; IV. PERSYARATAN LAINNYA TETAP MENGACU SEBAGAIMANA DOKUMEN LELANG (LEMBAR DATA PEMILIHAN & LEMBAR DATA KUALIFIKASI) V. KAMI INFORMASIKAN KEPADA SELURUH CALON REKANAN APABILA ADA PIHAK PIHAK YANG TIDAK BERTANGGUNG JAWAB MENGATASNAMAKAN KPA/PPTK/PANITIA MEMINTA IMBALAN DALAM BENTUK APAPUN MENJANJIKAN KEMENANGAN, UNTUK TIDAK DITANGGAPI DAN HENDAKNYA MELAKUKAN KLARIFIKASI/KONFIRMASI KE KANTOR UNIT LAYANAN PENGADAAN PROVINSI KALTIM, GEDUNG B LANTAI 3 KANTOR GUBERNUR KALTIM, JALAN GAJAHMADA NO.2. MARI KITA LAKSANAKAN PENGADAAN YANG BAIK DAN BENAR, MEWUJUDKAN PEMERINTAHAN BERSIH DAN BERWIBAWA MENUJU KALTIM MAJU 2018, TERIMA KASIH POKJA PENGADAAN ALAT LABORATORIUM STANDARISASI, KALIBRASI DAN INSTRUMENTASI UPTD.METROLOGI Ttd LAMPIRAN II. PERUBAHAN NOMENKLATUR RAB Nomor : 027/02/001-ALATLAB.METRO/IV/2015 Tanggal : 21 April 2015 RENCANA ANGGARAN BIAYA (RAB) Program : Peningkatan Sarana dan Prasarana Aparatur Kegiatan : Pengadaan Peralatan Gedung Kantor Pekerjaan : Belanja Modal Pengadaan Alat-Alat Laboratorium Fisika/Geologi/Geodesi Lokasi : Jl. Dahlia No. 6 Samarinda Sumber Dana : APBD Provinsi Kalimantan Timur Tahun Anggaran : 2015 ( Peralatan dan Perlengkapan Standar UPTD Metrologi) RAB SEMULA : Uraian No. 1 Mass Comparator 2 unit Satuan pkt Volume Harga Satuan (Rp.) Jumlah Harga (Rp.) 1.00 - - Kapasitas 22 g, readibility 1 mirogram - - Kapasitas 2.300 g, readibility 0,1 miligram - 2. Anak Timbangan Standar kelas E2, Massa Nominal 1-500 mg dan 1-5 kg, massa nominal 10 kg dan nominal 20 kg 3. set 1.00 - set 1.00 - paket 1.00 - Weigh Fork untuk 2 kg, 5 kg, Aluminium grip handler untuk 10-20 kg dan Weigh Fork untuk 500 g dan 1.000 g - 4. Master Meter Arus BBM ( 1 USD = Rp. 13.300,00) 5. Termocouple digital unit 2.00 - 6. Alat UjiThermohydrometer set 1.00 - 7 Alat Ukur Kelembaban/Thermometer Ruangan paket 1.00 - 8 Peralatan Kalibrasi Ukur Tetap paket 1.00 - 9 Bourje set 1.00 - 10 Meja Tahan Getar unit 5.00 - 11 Instalasi Uji Komparator Panjang paket 1.00 - 12 Environment meter unit 1.00 - 13 Mag+Probe with Leak Detection and Cabling (Spare Parts) paket 1.00 - 14 Dehumudyfier unit 5.00 - 15 Oven unit 1.00 - 16 Protactor (Alat Ukur Sudut) unit 1.00 - 17 Humidity unit 1.00 - 18 Stop Watch unit 1.00 - 19 Water Distiler unit 1.00 - 20 Power Analyzer unit 1.00 - 21 Precision Thermometer unit 1.00 - 22 5 in 1 Meter unit 1.00 - 23 CO2 Meter unit 1.00 - 24 Meter Air unit 1.00 - (I) Jumlah Harga Pekerjaan - (II) Pajak Pertambahan Nilai (PPn) = 10 % + (I) - (III) Jumlah Harga Pekerjaan termasuk PPn - (IV) Dibulatkan - Samarinda, April 2015 DIREKTUR PT/CV…………………. RAB PERUBAHAN : RENCANA ANGGARAN BIAYA (RAB) Program : Peningkatan Sarana dan Prasarana Aparatur Kegiatan : Pengadaan Peralatan Gedung Kantor Pekerjaan : Pengadaan Alat Laboratorium Standarisasi, Kalibrasi dan Instrumentasi UPTD METROLOGI Lokasi : Jl. Dahlia No. 6 Samarinda Sumber Dana : APBD Provinsi Kalimantan Timur Tahun Anggaran : 2015 Uraian No. 1 Mass Comparator 2 unit Satuan pkt Volume Harga Satuan (Rp.) Jumlah Harga (Rp.) 1.00 - - Kapasitas 22 g, readibility 1 mirogram - - Kapasitas 2.300 g, readibility 0,1 miligram - 2. Anak Timbangan Standar kelas E2, Massa Nominal 1-500 mg dan 1-5 kg, massa nominal 10 kg dan nominal 20 kg 3. set 1.00 - set 1.00 - paket 1.00 - Weigh Fork untuk 2 kg, 5 kg, Aluminium grip handler untuk 10-20 kg dan Weigh Fork untuk 500 g dan 1.000 g (Weighfork = Tweezers dalam spek) - 4. Master Meter Arus BBM ( 1 USD = Rp. 13.300,00) (lihat juga anwising) 5. Termocouple digital unit 2.00 - 6. Alat UjiThermohydrometer (Dalam spek Portable Digital Density Meters) set 1.00 - 7 Sensor Pelengkap Alat Ukur Suhu (Thermocouple Probe Surface) paket 1.00 - 8 Peralatan Kalibrasi Ukur Tetap paket 1.00 - 9 Bourje set 1.00 - 10 Meja Tahan Getar unit 5.00 - 11 Instalasi Uji Komparator Panjang paket 1.00 - 12 Environment meter unit 1.00 - 13 Mag+Probe with Leak Detection and Cabling (Spare Parts) paket 1.00 - 14 Dehumudyfier unit 5.00 - 15 Oven unit 1.00 - 16 Protactor (Alat Ukur Sudut) unit 1.00 - 17 Humidity unit 1.00 - 18 Stop Watch unit 1.00 - 19 Water Distiler unit 1.00 - 20 Power Analyzer unit 1.00 - 21 Precision Thermometer unit 1.00 - 22 5 in 1 Meter unit 1.00 - 23 CO2 Meter unit 1.00 - 24 Meter Air unit 1.00 - (I) Jumlah Harga Pekerjaan - (II) Pajak Pertambahan Nilai (PPn) = 10 % + (I) - (III) Jumlah Harga Pekerjaan termasuk PPn - (IV) Dibulatkan - Samarinda, April 2015 DIREKTUR PT/CV…………………. No 1 Nama Alat Mass Comparator Spesifikasi Teknis - Maximum Load 22 g - Readability 1 µg - Repeatability at nominal load (5x ABA, measure at) 1,5 µg (20 g) - Repeatability at low load (5x ABA, measure at) 0,7 µg (1 g) - Repeatability typical ABA 0,5 µg + 4x10-8 .Rgr - Electrical weighing range 0 - 22 g - Linerarity (electrical weighing range) ± 0,006 mg (6 µg) - Eccentric load deviation (at test load) 0,00 mg (20 g) - Setting time ≤ 3,5 s - Adjusment built-in ProFACT Dual Draft Shield Motorized (2x motorized) - Self centering hanging pan and grid pan - Color graphic display with touch screen operation - Smartsens for automatic operation Status Light Indicator - Green : Comparator Ready for Used - Yellow : in Process, automatic calibration - Red : Comparator not ready to used, error are shown Admissible environmental conditions - Temperature (oC) : 10 - 30 o - Max temp Change ( C /12h) : 0,5 - Relative humidity (%) : 40-70 For Verification/Calibration Weight - OIML Calibration Range E1 : 50 mg – 20 g - OIML Calibration Range E2 : 1 mg – 20 g - OIML Calibration Range F1 : 1 mg – 20 g - OIML Calibration Range F2 : 1 mg – 20 g - OIML Calibration Range M1 : 1 mg – 20 g MC Link Software for WeighhCom Application (Software koneksi ke PC/Komputer, untuk perhitungan kalibrasi AT) Pelatihan Penggunaan alat MC di Samarinda Pelatihan Kalibrasi Alat Timbang Bersertifikat, sesuai Standard ISO 17025 Instalasi MC oleh Tenaga Ahli Bersertifikat Pabrikan Sertifikat Hasil Pengujian dengan Komputerisasi Didukung oleh Service Center Terakreditasi ISO 9001 Jumlah 2 Mass Comparator - Maximum load 2.300 g - Readability 0,1 mg - Repeat ability at nominal load (5x ABA, measure at) 0,1 mg (2 kg) - Repeatability at low load (5x ABA, measure at) 0,08 mg (100 g) - Repeatability typical ABA 0,06 mg + 9x10-9.Rgr - Electrical weighing range 0 - 2.300 g - Linerarity (electrical weighing range) ± 1 mg - Eccentric load deviation (at test load) 0,0 mg (1 kg) - Setting time ≤ 3,5 s - Adjusment Built-in ProFACT Self Centering pan (LevelMatic) – eliminate corner load error Color Graphic display with touch screen operation SmartSens for Automatic Operation Status Light Indicator - Green : Comparator Ready to Used - Yellow : in Process, automatic calibration - Red : Comparator not ready to used, error are shown Level Control Warns if the balance is not correctly leveled Admissible environmental conditions - Temperature (oC) : 10 .. 30 o - Max temp Change ( C /12h) : 0,5 - Relative humidity (%) : 40-70 For Verification/Calibration Weight - OIML Calibration Range E1 : 1 kg – 2 kg - OIML Calibration Range E2 : 500 g – 2 kg - OIML Calibration Range F1 : 50 g – 2 kg - OIML Calibration Range F2 : 10 g – 2 kg - OIML Calibration Range M1 : 200 mg – 2 kg MC Link Software for WeighhCom Application (Software koneksi ke PC/Komputer, untuk perhitungan kalibrasi AT) Pelatihan Penggunaan alat MC di Samarinda Pelatihan Kalibrasi Alat Timbang Bersertifikat, sesuai Standard ISO 17025 Instalasi MC oleh Tenaga Ahli Bersertifikat Pabrikan Sertifikat Hasil Pengujian dengan Komputerisasi Didukung oleh Service Center Terakreditasi ISO 9001 3 Anak Timbangan E2 - Anak timbangan E2, Nominal 1 mg – 5 kg sebanyak 28 unit - Bahan Stainless steel with adjusting cavity - Density : 8,0 kg/dm3 - Nominal 1 mg – 500 mg bentuk wire - Nominal 1 g – 5 kg bentuk OIML standard, silynder with knob - Magnetic susceptibility < 0,01 - One Piece Design (MonoBloc) - Dilengkapi dengan wadah kotak plastik - Isi weight set : 1 mg (1 buah), 2 mg (2 buah), 5 mg ( 1 buah), 10 mg ( 1 buah), 20 mg (2 buah), 50 mg ( 1 buah), 100 mg (1 buah), 200 mg ( 2 buah), 500 mg ( 1 buah), 1 g (1 buah), 2 g (2 buah), 5 g ( 1 buah), 10 g ( 1 buah), 20 g ( 2 buah), 50 g ( 1 buah), 100 g ( 1 buah), 200 g ( 2 buah), 500 g ( 1 buah), 1 kg ( 1 buah) 2 kg ( 2 buah), 5 kg ( 1 buah) - Anak timbang individual E2, nominal 10 kg, dengan kotak plastik - Anak timbang individual E2, nominal 20 kg, dengan kotak plastik - Sertifikat Metrologi/Laboratorium kalibrasi KAN 4 Portable Digital Density Meters - - Measuring Range : 0 - 2 g/cm3 Resolution 0,0001 g/cm3 Accuracy : ± 0,001 g/cm3 Measurement units : Density, Spesific Grafity, Temperature Compensated Density, Temperature Compensated Spesific Grafity, Brix %, Alcohol, Baume Plato, API (table A, Band D), % Sulfuric Acid, User Defined Unit Temperature Measurement Range : 0 – 40 oC, resolution : 0,1oC, display C or F Temperature Compensation Automatic (Brix%, Alcohol, Plato, API, %Sulfuric acid) Calibration with dry air or pure water or other density standard Data memory up to 1.100 result Dot matrix LCD display with backlit Data interface RS232 or IrDA (optional) Battery operation Portable/handheld 5 Meja Tahan Getar/Tanpa Kaki - Ukuran : 60 x 90 x 15 cm - Toping (permukaan meja) – Granit/Marmer - Damping pad (peredam getaran) 6 Tweezers (WeighFork) - Straight tips for weights 1 mg – 20 g, length 115 mm - Straight tips for weights 1 mg – 20 g, length 220 mm - Straight tips for weights 20 mg – 200 g, length 140 mm - Bent tips for weights 20 g – 200 g, length 200 mm - Bent tips for weights 1 mg – 200 g, length 130 mm 7 Mastermeter Arus BBM (Mechanical Bulk Meters Dan Masterload II Electronic Meter Controller) Meter Type : Rotary Vane Positive Displacement Maximum Working Pressure : 10,5 bar (150 psi) Flow Range : 387 to 3870 LPM (85 to 850 GPM) Manifold Material : Steel Static Seals : High Nitrile Dynamic Seal : Fuorocarbon Rotor : Alumunium Flange Connection : 6’’ANSI 150 FF Typical Accuracy : ±0.02 % Repeatability : Within 0.02 % Fitted With : - Masterload II Electronic Master Meter Standar Consist Of : # Pulse Transmitter # Display Unit;Display;Volume Dispensed, Rate Of Flow, Totalizaer #Temperature Compensation # Power Supply Unit : Baseefa Approval for zone 1 area, 240 VAC # Tested To Master Meter Standard - Certificate Calibration From Metrology Unit - Yellow Label (Type Permission) From Direktorat Metrology Bandung 8 Bourje - Bahan Plat Kuningan Tebal minimal 4 mm - Terdiri dari masing-masing alat uji takaran kapasitas 0,5 dl; 1 dl; 2 dl; 0,5 liter; 1 liter; 2 liter; 5 liter; 10 liter dan 20 liter - Daya baca 1 mm - Dikemas dalam kotak kayu yang baik dan bagian dalamnya dilapisi kain yang non elektrostatis 9 Thermocouple digital - - Dapat digunakan dengan sensor yang berbeda Kokoh dan mudah dibawa Memiliki dua masukan untuk pengukuran Terdiri dari dua tampilan Mampu menampilkan dan menyimpan nilai maksimum, minimum dan rata-rata hasil pengukuran Pembacaan dalam °C, °F, atau °K Rentang Suhu -200 °C sampai dengan 1.372°C Tingkat ketelitian suhu diatas -100 °C adalah ±[0,05%+0,3°C] untuk tipe J, K, T, dan E, dibawah -100 °C adalah ±[0,20%+0,3°C] untuk tipe J, K, dan E, dan ±[0,50%+0,3°C] untuk tipe T 10 Sensor Pelengkap Alat Ukur Suhu (THERMOCOUPLE PROBESURFACE) - - 11 Dapat digunakan dengan sensor yang berbeda Kokoh dan mudah dibawa Memiliki dua masukan untuk pengukuran Terdiri dari dua tampilan Mampu menampilkan dan menyimpan nilai maksimum, minimum dan rata-rata hasil pengukuran panjang kabel 1,3 meter dan panjang probe min. 9,5 cm Pembacaan dalam °C, °F, atau °K Rentang Suhu -200 °C sampai dengan 1.372°C Tingkat ketelitian suhu diatas -100 °C adalah ±[0,05%+0,3°C] untuk tipe J, K, T, dan E, dibawah -100 °C adalah ±[0,20%+0,3°C] untuk tipe J, K, dan E, dan ±[0,50%+0,3°C] untuk tipe T Peralatan Kalibrasi Tangki Roda Ukur Ukur Tetap - Bahan : roda dari kuningan, as roda dari stainless steel/batang besi yang di cat - Terdiri dari 2 buah roda besar, diameter sekitar 28 cm atau lebih, dipasang mengapit 1 buah roda lebih kecil (roda pengarah), diameter sekitar 25 cm - Jarak antara roda besar 35 cm, roda pengarah berada ditengah-tengahnya - Ketiga roda dapat dipasang dan dilepas - Ban Ukur (Roll Meter) - Bahan dari Carbon Steel dilapisi nylon atau resin - Kapasitas maximum pengukuran 30 meter, daya baca 1 mm - Dikemas dalam gulungan sehingga mudah dibawa - Sertifikat kalibrasi dari direktorat metrologi Bandung Depth Tape - Bahan dari Stainless steel, atau carbon steel, dilengkapi bandul pemberat dari bahan stainless steel atau kuningan - Kapasitas pengukuran 20 meter, daya baca 1 mm - Dikemas dalam gulungan sehingga mudah dibawa - Sertifikat kalibrasi dari direktorat metrologi bandung Meter Gulung (Meter Saku) - Berupa rollmeter dengan ukuran lebih kecil - Bahan dari carbon steel dilapis resin - Kapasitas pengukuran 5 meter daya baca 1 mm - Sertifikat kalibrasi dari DIrektorat metrologi Bandung Mistar - Bahan : Stainless steel, lebar sekitar 2,5 cm, tebal sekitar 2 mm - Kapasitas pengukuran : 40 cm, daya baca 1 mm - Sertifikat kalibrasi dari direktorat metrologi Bandung Timbangan Pegas - Berupa timbangan kecil dengan system pegas tunggal, sederhana - Digunakan untuk memperkirakan besarnya kekuatan tarikan pada ban ukur, ketika pengukuran keliling tangki - Kekuatan maksimal 10 kg, daya baca 0,1 kg Waterpass - Bahan dari alumunium dilengkapi dengan kaca penglihat untuk memonitor kedataran Magnetic Clamp - Magnet electronic yang dapat bersifat besi biasa atau magnet dengan cara menyetel tombolnya - Dilengkapi dengan 2 batang pemegang dari stainless steel dan 2 alat pengencang - Digunakan untuk memegang mistar yang ditempelkan ke dinding tangki Bandul Pemberat - Bahan pipa Stainless Steel diameter sekitar 75 mm, panjang sekitar 20 cm - Dilengkapi dengan kaitan yang dapat dibuka/dipasang - Kedalam pipa dapat dimasukkan pemberat berupa timah atau logam lain, sehingga berat keseluruhan sekitar 5 kg Siku-Siku Pembaca - Bahan stainless steel, tebal sekitar 1 mm, panjang sekitar 15 cm, lebar sekitar 10 cm Katrol Tunggal - Bahan dari besi, jenis katrol tunggal biasa ukuran 3 inchi Pasta Air, Pasta Minyak Kawat Seling - Panjang 50 meter diameter sekitar 1 mm Tali Penarik - Berupa tambang rami atau tambang plastic, diameter sekitar ½ inch panjang 30 meter. Kotak Penyimpanan - Bahan kayu yang baik, tebal 1 cm atau lebih, ukuran disesuaikan untuk menyimpan seluruh peralatan strapping, kecuali tambang rami. Kunci Inggris Kunci Pas Kunci L Obeng (+) dan Obeng (-) Tang Kombinasi Sarung Tangan Pegangan Ban Ukur 12 Spare parts (ATG Probe) 1. MAG + PROBE WITH LEAK DETECTION (Setiap Probe / Sensor untuk 1 tangki dan sudah termasuk Kit Pelampung & Riser Cap) 2. CABLING Kabel data SWA 2 x 0,75 mm 13 Humidity Meter FEATURES Humidity + Temperature + Dew point are combined Sampling Time Approx. 0,8 second into one meter, intelligent and professional. 0,01 %RH resolution for the humidity reading degree resolution for the humidity reading. Fast humidity measuring response time. High accuracy and high precision. Temperature Dew point measurement. Manual and auto manual data logger. Data logger function with flexible sampling time selection, can save max. 1.000 reading data with recall. Just few panel buttons, easy operation. Microprocessor circuit assures maximum accuracy, provides special functions and features. Large LCD with two display, easy readout. Heavy duty & compact housing case, designed for easy carry out & operation. Records Maximum and Minimum readings with Recall. Auto shut off saves battery life. Data hold function for freezing the desired value Included on display. RS 232 PC serial interface. Show the humidity & temperature values on the LCD display at same time. Built-in low battery indicator. Wide humidity & temp. measuring range Separate humidity & temp. probe, easy operation. & remote measurement. General Specifications Circuit Custom one-chip of microprocessor LSI circuit. Display LCD size : 61 mm x 35 mm dual function LCD display. Measurement Unit : 1. Humidity 2. Temperature 3. Dew point Response Time 5 to 30 seconds typically @ Reach the 85% reading value Temperature compensation Automatic temp. compesation for humidity function. Sampling Time of Data Logger Manual : Push the data logger button once will save data one time. Auto: 1, 2, 10, 30, 60, 600, 1.800, 3.600 seconds Data: Hold Freeze the display reading. Memory Recall : Maximum & Minimum value. Sampling Time : Approx. 0,8 second Power off : Auto shut off saves battery life or manual, off by push button. Data Output : RS 232 PC serial interface. Operating : 0 to 50 0C. Operating Main instrument : Less than 85% R.H. Humidity Probe : 0 to 95 %RH. Power Supply DC 9V battery( Alkaline or Heavy duty type ). Power Current Approx. DC 4,6 mA. Weight : 306 g/ 0.67 LB. possible @ Battery is included. Dimension Main instrument : 180 x 72 x 32 mm (7,1 x 2,8 x1,3 inch) Humidity Sensor Probe : 197 mm ( 7,8 inch ) in length. Accessories Included : Instruction manual........................1 PC Humidity probe.............................1 PC Carrying case................................1 PC Optional Accessories : RS232 cable/UPCB-01, USB cable/USB-01, Data Acquisitio software, SW-U801-WIN Data Logger software, SW-DL2005 Electrical Specifications (23±5 0C) * Humidity/ Temperature 1. Humidity : - Range 10 % to 95 % R.H. - Resolution 0,01 % R.H - Accuracy ≥ 70% RH : ± (3% reading + 1% RH). < 70% RH : ± 3% RH. 2.Temperature : - Range 0 0C to 50 0C,32 0F to 122 0F. - Resolution 0,01 degree - Accuracy 0C – 0,8 0C, 0F – 1,5 0F. * Dew Point 0 C : Range -25,3 0C to 48,9 0C Resolution 0,01 0C 0 F : Range -13.5 0F to 120,1 0F. Resolution 0,01 0F 14 Dehumidifier (Pengatur Kelembaban) - - Dehumidifier with slim design and digital display, also has 4 wheels for easy mobility, washable filter, auto defrost function, continuous drainage, full tank indicator, 3-level fan speed and 24-hour timer, ionizer and oscillation functions. Capacity: 20 LITER 15 Alat Ukur Suhu dan Kelembaban Ruangan (Thermohygrometer) - 16 PROTACTOR (Alat Ukur Sudut) Rentang Suhu: 0 – 110 °C Rentang Kelembaban: 20 – 95% Mampu menyimpan 1.000 data suhu Mampu menyimpan 1.000 data kelembaban Resolusi suhu 0,1 °C Resolusi kelembaban 1% Mampu menyimpan daya listrik secara otomatis ketika listrik padam Didukung software penyimpan data dan sistem cetak otomatis data yang tersimpan FEATURES High - precision angle gage for accurate angle measurement of machines, molds and jigs Can be attached to height gages BENEFITS High accuracy High Precision SPECIFICATION Graduation : 5 min. (0o-90o-0o) Blade Edge Angle : 30o,45o&60o DESCRIPTION Universal Bevel Protractor 6 mm with Blade Length 17 Meter Air TYPICAL PERFORMANCE - Nominal Diameter : 3 “ - Starting Flow Rate : 0,3 m3/h - Accuracy ± 2% from : 1,2 m3/h - Accuracy ± 5% from : 0,75 m3/h - Admissible peak flow (10’ max) : 250 m3/h - Max. admissible flowrate (continuous) : 120 m3/h - Head loss at Qmax : 0,55 bar - Max. admissible temperature : 50 °C - Max. admissible pressure : 20 bar - Min. scale interval : 2 L - Indicating range : 9999999,9 m3 - Cyble HF pulse weight : 100 L 18 Stop Watch - Times single or cumulative events from 1 μs to 999,999 hrs - Timing resolution to 0.2 μs - Selectable HH.MM.SS clock format or H, M or S decimal format - Inputs from NPN or PNP proximity switches, contact closures, digital - logic, magnetic pickups down to 12 mV, or AC inputs up to 250 Vac - Triggers on positive or negative pulse edges - - Universal 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac power - Transducer excitation output (isolated) - Wide choice of options: 2 or 4 relays, mechanical or solid state (isolated) 1 or 2 analog outputs (isolated) Serial data I/O: Ethernet, USB, RS485, RS232 (isolated) 19 Oven VENTILATION AND CONTROL - Adjustment of pre-heated fresh air admixture by air flap control in 10% steps - Vent connection with restrictor flap - Adaptive multifunctional digital PID microprocessor controller with high-definition TFT-colour display - Self-diagnostics for fault analysis - 1 Pt100 sensor DIN class A in 4-wire-circuit - Digital timer adjustable from 1 minute to 99 days, 23 hours - Parameters adjustable on ControlCOCKPIT: temperature (Celsius or Fahrenheit), fan speed, air flap position, programme time, time zones, summer time/winter time - Set point WAIT function - the process time does not start until the set temperature is reached - Resolution of display for setpoint values 0.1°C up to 99.9°C, 0.5°C from 100°C and for actual values 0.1°C (LED) - Calibration facility directly at ControlCOCKPIT for three freely selectable temperature values - Programme stored in case of power failure - Incl. works calibration certificate for +160°C TEXTURED STAINLESS STEEL CASING - Fully insulated stainless steel door with 2-point locking (compression door lock) - Rear zinc-plated steel INTERIOR-HEATING CONCEPT - Easy-to-clean interior,made of stainless steel,reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides - 1 stainless steel grid TEMPERATURE RANGE - Up to +300°C VOLTAGE/POWER RATING - 230 V (+/- 10%), 50/60 Hz 20 Water Distiller - Good distillate quality, conductivity approx. 2,3 μs / cm at 25 °C - Heating element made of stainless steel, material no. 1.4876 - Thermostatic low water cut-off, to protect the heating element in case of low water - Energy-saving through distillation of the heated cooling water - Degassing of carbon dioxide through vent in the top - Evaporator with baffle is easily accessible by lifting the lids. Material: stainless steel, material no. 1.4301 - Storage tank for distillate accepts double the hourly capacity of the unit. Material: stainless steel, material no. 1.4301 - Condenser (cooling coil) in the storage tank, easily exchangeable. Material: stainless steel, material no. 1.4301 - Water supply through a built-in solenoid valve with connection for water pressure hose 1/2 inch (inner Ø 12,7 mm) - Cooling water pressure required: > 3 bar to max. 7 bar. After switching on the main switch the solenoid valve opens the water supply and closes it once the storage tank is full, thus avoiding unnecessary waste of water - Cooling water outlet with hose connection 3/4 inch (inner Ø 19 mm). Water that has not been condensed flows off through the cooling water outlet - Distillate withdrawal through the drain cock on the front of the unit. The drain cock can be opened in either continuous or touch position - An electronic level switch switches the still off when the storage tank is full and restarts it automatically when distillate is withdrawn 21 Precision Thermometer FEATURES - Professional thermometer with high accuracy & 0,01 resolution. PT 100 probe input cooperate with an 0.00385 alpha coefficient, meet DIN IEC 751. - Cooperate with 4 wires Pt 100 ohm probe, high precision. - Wide range display from -199,99 to 850 °C. - Build in °C & °F select button on the front panel. - Build in 0,01& 0,1 select switch on the front panel. - RS 232 computer serial interface. - Super large LCD with unit display, easy readout. - Data hold function to store the desired value. - Memory function to record the maximum & - minimum reading with recall. Built-in low battery indicator. Optional carrying cases are available. PROBE TYPE Platinum PT 100 ohm FUNCTIONS °C, °F, 0,01, 0,1 Data hold. RESOLUTION 0.01 °C /0.1 °C, 0.02 °F /0.1 °F. CIRCUIT Use the software to make linearity correction instead the traditional hardware circuit PROBE INPUT SOCKET DIN 4 pin socket SAMPLING TIME Approx. 0,4 second DATA OUTPUT RS232 PC serial interface OPERATING TEMPERATURE 0 to 50 °C (32 to 122 °F). OPERATING HUMIDITY Less than 80% RH OPTIONAL ACCESORIES Carying case, PT 100 probe, RS232 cable, USB cable application software Electrical Specifications (23±5 0C) 1. °C : - Range -199,99 to 199,99 0C. - Resolution 0,01 0C - Range 200,0 to 850,0 0C. - Resolution 0,1 0C . 2. °F : - Range -199,99 to 392,00 0F. - Resolution 0,01 0F - Range 392,0 to 1.562,0 0F. - Resolution 0,1 0F 22 5 in 1 Meter FEATURES - 5 in 1 professional measuring instrument: Anemometer, Hygrometer, Type K Thermometer, Light meter, Sound level meter. - Anemometer use low-friction ball bearing mounted wheel design provides high accuracy. - Light meter use exclusive photo diode and colorcorrection filter light sensor, spectrum meets C.I.E. photopic. - Type K thermometer use standard type K (NiCr-NiAl) thermocouple input jack suitable for all kinds of type K probe. - Humidity meter use high precision humidity sensor with fast response time. - Sound level meter's characteristic is simulated as " Human Ear Listing" response, used the " - - A " frequency weighting and " Fast " time weighting to meet IEC 61672 class 2. Sound level meter can cooperate the external 94 dB sound calibrator and just press the front buttons to make the calibration Built- in microprocessor circuit assures excellent performance and accuracy. Concise and compact buttons arrangement, easy operation. Memorize the maximum and minimum value with recall. Hold function to freeze the current reading value. 0 C /0F detection by pressing button on the front panel. Lux/Feet-candle selection by pressing front button. Air velocity measuring units selection by pressing button on the front panel for five kinds of units. Multi channel display for relative humidity and temperature measured values or air velocity and temperature measured values at the same time. Zero button design makes light meter calibration. Rough housing case suitable for handling with one hand, RS232/USB computer data bus GENERAL SPESIFICATIONS MEASUREMENT 5 in 1 : Anemometer ( Air velocity + Temp. ) Humidity ( %RH + Temp. ) Light Thermometer ( type K ) Sound level OPERATING HUMIDITY Max. 80% RH. OPERATING TEMPERATURE 0 to 50°C (32 to 122 °F). DATA OUTPUT RS232/USB PC serial interface. - Connect the optional RS232 cable UPCB-02 will get the RS232 plug. - Connect the optional USB cable USB-01 will get the USB plug. OPTIONAL ACCESORIES Carying case, Type K Temperature probe, Sound Calibrator/SC-941, USB Cable/USB-01, RS232 cable/UPCB-02, Data Acquisition Software, SWU801-WIN, AC to DC power adapter. 23 Power Analyzer FEATURES - Multi-functions : WATT, VA, Whr, COS θ (Power factor ), ACV, ACA, DCV, DCA, Hz, ohm. - True AC power( Watt ) & apparent power (VA) measurement. - True rms display for ACV, ACA. - 0.1 W resolution ( < 1000 W ), high precision an high resolution in the low wat range, good performance for low power LED lamp watt measurement. - Supper large LCD, easy to read-out, display the Watt, Power factor, Voltage & Current value at the same time. - Accept different kinds current input signal as direct input, inductive clamp probe or CT ( current transformer ). - Auto range. - Built-in peak hold & data hold function. - Watt & VA measurement with Hi, low alarm setting capability. - RS-232 output interface. - Exclusive custom exclusive design LSI circuit, provides high accuracy, reliability and durability. - Built-in over input indication. - Power supply by batteries or AC to DC adapter. - Built-in low battery indicator . - Durable bench type housing plastic case with carrying handle. GENERAL SPECIFICATIONS Multi-display unit, show Volt, Ampere, Watt, Power factor or Hz at same time. - Measurement : WATT, VA, Whr,, Power factor, ACV, ACA, DCV, DCA, Hz, ohm. - Zero Adjustment : Whr: External adjustment by push button. DCV, ACV, DCA, ACA : Automatic adjustment. - Polarity : Automatic switching, "-" indicates reverse polarity. - Current input mode : Direct input, inductive clamp probe or CT. - Data Output : RS232 serial interface. - Sampling Time : W, VA, ACA, ACV, COS θ , Hz : Approx. 1.5 Sec. DCV, DCA, OHM : Approx. 1 Sec. - Operating Temp. : 0 to 50 °C (32 to 122 °F). - Operating Humidity : Less than 80 % R.H.. - Power Consumption : Approx. DC 55 mA - ELECTRICAL SPECIFICATIONS - Watt (AC, true power), current mode from direct input Range : 6.000 Watt Resolution : 0,1 Watt (< 1.000W) 1 Watt (≥ 1000W) Accuracy ± (1,5% + 5d) - Watt (AC, true power), current input cooperate with inductive probe or CT Range : 0,1 to 999,9 Watt Resolution : 0,1 Watt Range : 9.999 Watt Resolution : 1 Watt Range : 99,99 KW Resolution 0,01 KW Range : 999,9 KW Resolution 0,1 KW - VA (AC, apparent power), current mode from direct input Range : 99,99 VA Resolution : 0,01 VA Range : 999,9 VA Resolution : 0,1 VA Range : 9,999 VA Resolution 1 VA Accuracy : ± (2% + 2d) - POWER FACTOR current mode from direct input only Range : 0,01 to 1,00 Resolution : 0,01 Accuracy : ± (1,5% + 2d) - AC VOLTAGE (true rms), DC VOLTAGE Range : 0,1 V to 299,9 V Resolution : 0,1 V Range : 300 V to 600 V Resolution : 1 V Accuracy : DCV : ± ( 1 % + 1d ) ACV (≤10 V) : ± ( 1 % + 7d ) ACV (11 V to 100 V) : ± ( 1 % + 5d ) ACV (Others) : ± ( 1 % + 1d ) - AC CURRENT (true rms), DC CURRENT current mode from direct input - ACA Range : 0,05 A to 1,999 A, Resolution : 1 mA, Accuracy : ± ( 1 % + 3d ) Range : 2,00 A to 10,00 A, Resolution : 10 mA, Accuracy : ± ( 1 % + 3d ) - DCA Range : 0,01 A to 10,00 A, Resolution : 10 mA, Accuracy : ± ( 1 % + 1d ) - AC CURRENT (true rms), DC CURRENT current mode from inductive probe - ACA Range : < 20 A, Resolution : 0,01 A, Range : 20 A to 199,9 A, Resolution : 0,1 A Range : 200 A to 1.000 A, Resolution : 1 A - DCA Range : 1000 A, Resolution : 1 A, Accuracy : Meter voltage range accuracy plus Inductive Probe’s accuracy ACA is true rms - AC CURRENT Current mode from CT (current transformer) Range : CT 100/5A, 0,1 to 200 A Resolution : 0,01 A, < 20 A, 0,1 A, ≥ 20 A Range : CT 1.000/5A, 1 to 2.000 A Resolution : 0,1 A, < 200 A, 1 A, ≥ 200 A Accuracy : Meter current range accuracy plus CT (current transformer) accuracy. ACA is true rms - Watt Hour current from direct input Range : 0,001 Whr to 9,999 Whr Resolution : 0,001 Whr Range : 10,00 Whr to 99,99 Whr Resolution : 0,01 Whr Range : 100,0 Whr to 999,9 Whr Resolution : 0,1 Whr Range : 1.000 Whr to 9999 Whr Resolution : 1 Whr Range : 10 KWhr to 99,99 KWhr Resolution : 10 Whr Range : 100 KWhr to 999,9 KWhr Resolution : 100 Whr Range : 1.000 KWhr to 9999 KWhr Resolution : 1 KWhr - When Watt Hour value over 9999 K Whr, the Display value will reset to 0000 K Whr, then count up again. - Accuracy & other specification requirement same as " Watt " range exactly - OHMS Range : 9.999 ohm Resolution : 1 ohm Range : 19,99 Kohm Resolution : 1 ohm Accuracy : ± (1% + 1d) - Auto range. - Overload protection “ Max. AC/DC 300V. 24 CO2 Meter FEATURES - NDIR method principal for CO2 ( Carbon dioxide ) measurement, available for long term operation. - High repeatability and high accuracy. - Two probes, one is for CO2/Temp. measurement, the other probe is for Humidity/Temp./Dew point measurement. - Separate probe, easy operation and convenient for remote measurement. CO2 function with alarm setting. Humidity measurement with fast response time. Large S-TN LCD, high contrast, easy readout. Data hold function for freezing the desired value on display. Records Maximum and Minimum readings with Recall. RS232/USB computer interface. Microprocessor circuit assures maximum possible accuracy, provides special functions and features. Heavy duty & compact housing with hard carrying case, designed for easy carry out & operation. Auto shut off is available to save battery life. Power supply from batteries or DC 9V adapter in. GENERAL SPESIFICATIONS CIRCUIT Custom one-chip of microprocessor LSI circuit. MEASUREMENT CO2 ( Carbon dioxide ), Temperature, Humidity UNIT CO2 : ppm Humidity : % RH Dew point : °C, °F Temperature : °C, °F DATA OUTPUT RS232/USB PC serial interface. - Connect the optional RS232 cable UPCB-02 will get the RS232 plug. - Connect the optional USB cable USB-01 will get the USB plug. OPTIONAL ACCESORIES RS232 cable/UPCB-02, USB cable, USB-01 Data Acquisition Software, SW-U801-WIN ELECTRICAL SPECIFICATIONS (23 ± 5 °C) - CO2 (Carbon dioxide) Range : 0 to 4.000 Watt Resolution : 1 ppm Accuracy : ± 40 ppm * ≤ 1.000 ppm ± 5% of reading * > 1.000 ppm ≤ 3.000 ppm ± 250 ppm typically * > 3.000 ppm, reference only Repeatibility : ± 20 ppm * ≤ 3.000 ppm - Temperature Range : 0 °C to 50 °C, 32 °F to 122 °F Resolution : 0,1 degree Accuracy : °C – 0,8 °C, °F – 1,5 °F - Humidity/ Temperature/ Dew point Humidity Range : 10% to 95 % R.H. Resolution : 0,1 % R.H. Accuracy : ≥ 70 % : ± (3% reading + 1% R.H.) < 70 % R.H. : ± 3 % R.H. - Temperature Range : - 0 to 50 0C, 32 to 122 0F - Resolution 0,1 0 - Accuracy : °C – 0,8 °C, °F – 1,5 °F. - Dew Point 1. °C : - Range -25,3 to 48,9 0C. - Resolution 0,1 0C . 2. °F 25 Environment Meter : - Range -13,5 to 120,1 0F. - Resolution 0,1 0F FEATURES * 11 in 1 professional environmen tinstruments: 1. Airvelocty/Temp., 2. Humidity/Temp., 3. UV Light 4. Barometer,5. CFM,CMM,6. Dewpoint, 7. Wet bulb, 8. Wind chill, 9.Heat index, 10. Altitude, 11. PT 1000 ohm Temp. (optional) - Tiny bone shape with light weight and small size case design are suitable for handling with one hand. - Wristlet design provides extra protection to the instrument especially for user one hand operation. - Low-friction ball bearing mounted wheel design provides high accuracy at high and low air velocity - UV sensor structure The exclusive UV photo sensor with the cosine correction filter. - High precision humidity sensor with fast response time. - Build in baro sensor for the atomsphere value and altitude measurement precisely. - Optional PT 1000 ohm Temp.probe for the precision Temp. measurement. - Built in microprocessor circuit assures excellent performance and accuracy - Concise and compact buttons arrangement, easy operation - Memorize the maximum and minimum - value with recall. ℃/℉ detection by pressing button on the front panel. Hold function to freeze the current reading value. GENERAL SPECIFICATIONS - Display : 8 mm LCD display - Measurement : Airvelocty/Temp, Humidity/Temp., UVLight, Barometer, CFM,CMM, Dewpoint, Wetbulb, Windchill, Heatindex, Altitude, PT 1000 ohm Temp.(optional) Samarinda, Maret 2015 Kuasa Pengguna Anggaran, Ttd Ir. H. ERWINSYAH, M.Si. NIP. 19630805 199212 1 002