1 - SMC

Transcription

1 - SMC
Information
1-16-4 Shinbashi, Minato-ku,
Tokyo 105-8659, JAPAN
URL http://www.smcworld.com
©2005 SMC Corporation
All Rights Reserved
04-EU515-UK Issued: June, 2005
D-DNP P-120 (DN)
Serial Wiring
5 Port Solenoid Valve for EX510
Series VQZ
Manifold Variations
Body Ported
A, B port size
Piping with One-touch fitting
Series
Metric size
ø3.2
ø4
ø6
Port piping
Inch size
ø8
ø10
ø1/8"
ø5/32"
ø1/4"
ø5/16"
ø3/8"
M5
1/8
1/4
VQZ1000
VQZ2000
VQZ3000
Base Mounted
A, B port size
Piping with One-touch fitting
Series
Metric size
ø3.2
ø4
ø6
Port piping
Inch size
ø8
ø10
ø1/8"
ø5/32"
ø1/4"
ø5/16"
ø3/8"
M5
1/8
1/4
VQZ1000
VQZ2000
VQZ3000
Refer to Best Pneumatics catalogue for detailed specifications and precautions.
1
EX510 Serial Wiring
Series VQZ1000/2000/3000
Body Ported
How to Order Manifold
VV5QZ 1 2
SA
-Q
08
Manifold series
1
2
3
Option
VQZ1000
VQZ2000
-
SI unit COM.
-
+COM.
N
–COM.
K
Stations
2 stations
...
...
08
8 stations
Note 1) Maximum 16 stations
(For special wiring
specifications)
How to Order Valve Manifold Assembly (Example)
Example
VQZ2320-5L0-C6-Q
Cylinder port size
C6: With one-touch
fitting for ø6
VQZ2220-5L0-C6-Q
VQZ2120-5L0-C6-Q
U
3
sid
1
e
6
7
5
0
1
ta
... S
... 1
... 2
... 3
... 4
... 5
... 6
... 7
n
14
15
R2
P
R1
8
9
VV5QZ22-SA07-Q
ns
tio
D
e
sid
VV5QZ22-SA07-Q
∗ VQZ2120-5L0-C6-Q
∗ VQZ2220-5L0-C6-Q
∗ VQZ2320-5L0-C6-Q
1 set (Type SA, 7 station manifold base part no.)
2 sets (Single solenoid part no.)
3 sets (Double solenoid part no.)
2 sets (3 position type no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
Enter in order starting from the first station on the D side.
Add the valve and option part number under the manifold base part number. In
the case of complex arrangement, specify them on the manifold specification
sheet. For a manifold for an EX510, the length of the lead wire for a connector
assembly depends on the number of stations. Therefore, the manifold
assembly is shipped with the valves (including blanking plates) and connector
assembly mounted on it, as the standard specification. Be sure to specify the
part nos. of the solenoid valves to be mounted.
2
Special wiring specification
(Except double wiring)
Note) As for , enter the number from the DIN rail
dimensions table on page 7. For L dimension,
refer to the dimensions of each manifold on
page 12 to 14.
Symbol No. of stations
02
None
With DIN rail (Rail length: Standard)
D
Without DIN rail (With bracket)
D0
D Note) With DIN rail (Rail length: Special)
VQZ3000
P, R thread type
-
Rc
00N
00T
00F
NPT
NPTF
G
Body Ported
Series VQZ1000/2000/3000
How to Order Valve
VQZ 1 1 2 1
Thread type
Series
1
2
3
-Q
C6
5 M0
VQZ1000
-
Rc
VQZ2000
N
T
F
NPT
VQZ3000
NPTF
G
Type of actuation
1
2
3
4
5 Note 1)
8
9
Manual override
2 position single
2 position double
-
Non-locking push type (Tool required)
3 position closed center
B
Locking type (Tool required)
3 position exhaust center
Electrical entry
3 position pressure center
L0
M0
3 port for mixture mounting N.C.
3 port for mixture mounting N.O.
Seal
Metal seal
A, B port size
Thread piping
Rubber seal
Symbol
Function
Symbol
M plug terminal without connector
Note 1) With light and surge voltage suppressor
Note) Except VQZ1000 metal seal type.
0
1
L plug terminal without connector
Specifications
M5
02
-
Standard
Symbol
High pressure Note 1)
C3
C4
C6
C8
C10
External pilot Note 3)
Note 1) Metal seal only
Note 2) For an operation under continuous
energiging, use a low-watt type.
Note 3) Applicable to VQZ2000 and 3000.
Rated voltage: 24 VDC
VQZ1000
VQZ2000
VQZ3000


—
1/4
—
—

VQZ1000
VQZ2000
VQZ3000
—
—


—
With one-touch fitting for ø6



With one-touch fitting for ø8
—
—
With one-touch fitting for ø10
—
—



One-touch fitting (Metric size)
K
Y
R
Low wattage type (0.5 W) Note 2)
Port size
M5
Port size
With one-touch fitting for ø3.2
With one-touch fitting for ø4
One-touch fitting (Inch size)
Symbol
Port size
VQZ1000
VQZ2000
VQZ3000
N1
N3
N7
N9
N11
With one-touch fitting for ø1/8"
—
—


—
With one-touch fitting for ø1/4"



With one-touch fitting for ø5/16"
—
—
With one-touch fitting for ø3/8"
—
—
With one-touch fitting for ø5/32"



3
Series VQZ1000/2000/3000
Dimensions/VQZ1000
119 (3 position)
110 (Double)
77 (Single: Metal)
Indicator light
75 (Single: Rubber)
(20)
54.5
55
The broken lines indicate the
DIN rail mounting style [-D].
≈ 10
(For C3, C4, C6)
M plug connector (M)
PE port
12.5
(20)
48
46
(For M5)
Indicator light
16.5 16.5
23.5
4 x 1/8
3(R2), 5(R1) port
31
2 x 1/8
1(P) port
49
L plug connector (L)
4 x ø4.5 mounting hole
n x C3, C4, C6, M5
<4(A), 2(B) port>
C3: One-touch fitting for ø3.2
C4: One-touch fitting for ø4
C6: One-touch fitting for ø6
M5: M5 thread
(6)
(35)
(5.5)
(DIN rail clamp screw)
(11)
7.5
27.5
20
Connector lock pin
U side
n
3
R2
R1
P
5
1
8
2
2
2
2
2
3
2
2
1
(n-1) x 12
L3
L2
L1
4
L4
4
4
14
4
12
4
1
5
R1
P
3
R2
Stations
4
(5.25)
PWR
4
COM
5
4
6
2
4
7
5.5
8.3
Manual
override
D side
5.5
8.3
81 (Single: Rubber)
83 (Single: Metal)
122 (Double)
131 (3 position)
Dimensions
n
L
L1
L2
L3
L4
Maximum 16 stations
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
80
80
80
80
80
92
104
116
128
140
152
164
176
188
200
88
88
88
88
88
100
112
124
136
148
160
172
184
196
208
112.5
112.5
112.5
112.5
112.5
125
137.5
150
162.5
175
187.5
200
212.5
225
237.5
123
123
123
123
123
135.5
148
160.5
173
185.5
198
210.5
223
235.5
248
Note 1) “L” dimensions for 2 ~ 6 stations are the same. Valves are arranged from the “D” side.
4
Body Ported
Series VQZ1000/2000/3000
Dimensions/VQZ2000
137.5 (3 position)
124.5 (Double)
92 (Single)
62
(20)
64.3
Indicator light
The broken lines indicate the
DIN rail mounting style [-D].
11.5
16.5
(20)
52
58
(For M5)
≈ 10
(For C4, C6)
M plug connector (M)
Indicator light
PE port
21
21
2 x 1/4
1(P) port
4 x 1/4
3(R2), 5(R1) port
60
31
L plug connector (L)
4 x ø4.5 mounting hole
n x C4, C6, M5
<4(A), 2(B) port>
C4: One-touch fitting for ø4
C6: One-touch fitting for ø6
M5: M5 thread
(35)
(5.5)
(DIN rail clamp screw)
(11)
34.5
27
(7.5)
U side
n
Connector lock pin
P
R2
1
3
R1
5
4
B
8
4
B
A
2
7
B
B
2
A
2
4
4
B
L1
(n-1) x 17
4
L3
5
A
L2
4
L4
A
2
6
4
B
A
2
3
2
4
B
17
A
2
A
18
1
5
1
3
R1
P
R2
5
Stations
D side
66
Manual
override
(5.25)
PWR
COM
2
10.25
10.25
98 (Single)
136.5 (Double)
149.5 (3 position)
Dimensions
n
L
L1
L2
L3
L4
Maximum 16 stations
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
94
94
94
94
111
128
145
162
179
196
213
230
247
264
281
104
104
104
104
121
138
155
172
189
206
223
240
257
274
291
125
125
125
125
150
162.5
175
200
212.5
237.5
250
262.5
287.5
300
312.5
135.5
135.5
135.5
135.5
160.5
173
185.5
210.5
223
248
260.5
273
298
310.5
323
Note 1) “L” dimensions for 2 to 5 stations are the same. Valves are arranged from the “D” side.
5
Series VQZ1000/2000/3000
Dimensions/VQZ3000
145 (3 position)
132 (Double)
102.5 (Single)
(20)
64
Indicator light
21
21
31
PE port
11.5
16.5
(20)
57
65.5
Indicator light
60
2 x 1/4
1(P) port
L plug connector (L)
(35)
(5.5)
4 x ø4.5 mounting hole
(DIN rail clamp screw)
n x C6, C8, C10, 02
<4(A), 2(B) port>
C6: One-touch fitting for ø6
C8: One-touch fitting for ø8
C10: One-touch fitting for ø10
02: 1/4
(4)
36
27
(11)
(7.5)
Connector lock pin
U side
n
5
R1
4 x 1/4
3(R2), 5(R1) port
(For 02)
≈ 10.5
(For C6, C8)
M plug connector (M)
≈ 17.5
(For C10)
The broken lines indicate the
DIN rail mounting style [-D].
3
R2
P
1
8
2
A
4
A
2
B
7
2
B
2
4
4
A
2
B
L1
(n-1) x 20
A
L2
5
4
L4
A
L3
4
B
6
4
2
2
A
B
1
PWR
P
COM
4
26
2
B
4
20
A
1
3
R2
11
B
3
5
R1
Stations
D side
(5.25)
Manual override
9 9
10.25
10.25
108.5 (Single)
144 (Double)
157 (3 position)
Dimensions
n
L
L1
L2
L3
L4
Maximum 16 stations
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
70
70
90
110
130
150
170
190
210
230
250
270
290
310
330
92
92
112
132
152
172
192
212
232
252
272
292
312
332
352
112.5
112.5
137.5
162.5
175
200
212.5
237.5
262.5
275
300
312.5
337.5
362.5
375
123
123
148
173
185.5
210.5
223
248
273
285.5
310.5
323
348
373
385.5
Note 1) “L” dimensions for 2 to 3 stations are the same. Valves are arranged from the “D” side.
6
Body Ported
Series VQZ1000/2000/3000
Manifold Option
Blanking plate assembly
VVQZ1000-10A-2 (VQZ1000)
VVQZ2000-10A-2 (VQZ2000)
VVQZ3000-10A-2 (VQZ3000)
It is used by attaching on the manifold block for being
prepared for removing a valve for maintenance reasons
or planning to mount a spare valve, etc.
L
DIN rail
12.5 5.25
(Pitch)
AXT100-DR-
Each manifold can be mounted on a DIN rail.
Order it by indicating an option symbol for DIN
rail mounting style, -D.
The DIN rail is approximately 30 mm longer than
the length of manifold.
5.5
35
25
∗ As for , enter the number from the DIN rail dimensions table.
For L dimension, refer to the dimensions of each manifold.
7.5
1.25
L Dimension
L = 12.5n + 10.5
No.
1 2 3 4 5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20
L dimension 23 35.5 48 60.5 73 85.5 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5
No.
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
L dimension 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5
Blanking plug
KQP-23-X19
KQP-04-X19
KQP-06-X19
KQP-08-X19
KQP-10-X19
L
A
øD
Dimensions
Color: White
Applicable
fittings size ød
Model
A
L
D
3.2
4
6
8
10
KQP-23-X19
KQP-04-X19
KQP-06-X19
KQP-08-X19
KQP-10-X19
16
16
18
20.5
22
31.5
32
35
39
43
3.2
6
8
10
12
Silencer (For Manifold EXH port)
63
Silencer is installed in the EXH port.
ø22
38
ø13
Dimensions
AN110-01
Model
AN200-02
VQZ1000
VQZ2000
VQZ3000
Silencer P/N
AN110-01
AN200-02
AN200-02
For a silencer to be mounted in a single valve unit, refer to Best Pneumatics catalogue.
Port plug
VVQZ100-CP (VQZ1000/ VQZ2000)
VVQZ2000-CP (VQZ3000)
Used to block a cylinder port when changing 5 port
valves into 3 port valves, etc.
7
Series VQZ1000/2000/3000
Manifold Option
Connector assembly
For single solenoid (AXT661-81A-)
For double solenoid (AXT661-82A--)
(Red)
(Red)
A CB
A CB
A CB
(Black)
(Black)
Housing
Housing
How to Order Connector Assembly
(for a manifold with 8 stations or less with an unspecified layout)
Series
VV5QZ12
VV5QZ22
VV5QZ32
Assembly part no.
Connector mounting position
AXT661-81A-4
Single: for 1 to 8 stations
AXT661-82A-4-8
Double: for 11 to 8 stations
AXT661-81A-5
Single: for 11 to 8 stations
AXT661-82A-5-10
Double: for 11 to 8 stations
AXT661-81A-6
Single: for 11 to 8 stations
AXT661-82A-6-11
Double: for 11 to 8 stations
Note) Since these connector assemblies are used when adding stations or for maintenance, there are no part nos. on them.
Connector assembly
Housing (1 set 8 pieces)
AXT661-81-
SY3000-44-3A
(Red)
(+)
B C A
(–)
(–)
(+)
Triangular mark
Connector
(Black)
How to Order Connector Assembly
(for a manifold with a specified layout)
Series
VV5QZ12
VV5QZ22
VV5QZ32
Assembly part no.
Connector mounting position
AXT661-81-5
A side
AXT661-81-9
B side
AXT661-81-6
A side
AXT661-81-10
B side
AXT661-81-6
A side
AXT661-81-11
B side
AXT661-81-9
A side
AXT661-81-14
B side
AXT661-81-6
A side
AXT661-81-11
B side
AXT661-81-11
A side
AXT661-81-16
B side
For 1 to 8 stations
For 9 to 16 stations
For 1 to 8 stations
For 9 to 16 stations
For 1 to 8 stations
For 9 to 16 stations
Note 1) Since these connector assemblies are used when adding stations or for maintenance, there are no part nos. on them.
Note 2) After inserting the connector assembly into the housing, slightly pull the lead wire to make sure it does not pull out.
Do not reuse the lead wire once it has been inserted.
Note 3) Please note that the wires are longer than the actual wiring distance.
8
9
EX510 Serial Wiring
Series VQZ1000/2000/3000
Base Mounted
How to Order Manifold
VV5QZ 1 5
SA
-Q
08 C4
Option
Manifold series
1
2
3
VQZ1000
-
VQZ2000
D
D0
D
VQZ3000
SI unit COM.
-
+COM.
N
–COM.
Without DIN rail (With bracket)
With DIN rail (Rail length: Special)
Note 1) Applicable to VQZ2000 and 3000.
Thread type
Symbol No. of stations
2 stations
...
...
08
With DIN rail (Rail length: Standard)
N Note 1) With label plate
Special wiring specification (Except double wiring)
K
R Note 1) External pilot
Stations
02
None
8 stations
Note 1) Maximum 16 stations
(For special wiring
specifications)
-
Rc
N
T
F
NPT
G
A, B port size
Thread piping
VQZ1000
VQZ2000
VQZ3000
M5

—
—
1/8
—

—
1/4
—
—

VQZ1000
VQZ2000
VQZ3000
—
—
With one-touch fitting for ø8
—



—
With one-touch fitting for ø6



With one-touch fitting for ø10
—
—

Mixture of port size



VQZ2000
VQZ3000
—
—
—
Port size
Symbol
How to Order Valve Manifold Assembly (Example)
NPTF
M5
01
02
One-touch fitting (Metric size)
Example
VQZ2350-5L0-Q
VQZ2250-5L0-Q
VQZ2150-5L0-Q
Symbol
C3
C4
C6
C8
C10
CM
Port size
With one-touch fitting for ø3.2
With one-touch fitting for ø4


One-touch fitting (Inch size)
3
U
sid
1
e
6
7
5
0
1
... S
... 1
... 2
... 3
... 4
... 5
... 6
... 7
n
14
15
R2
P
R1
8
9
VV5QZ25-SA07C6-Q
ns
tio
ta
D
e
sid
VV5QZ25-SA07C6-Q
∗ VQZ2150-5L0-Q
∗ VQZ2250-5L0-Q
∗ VQZ2350-5L0-Q
1 set (Type SA, 7 station manifold base part no.)
2 sets (Single solenoid part no.)
3 sets (Double solenoid part no.)
2 sets (3 position type no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
Enter in order starting from the first station on the D side.
Add the valve and option part number under the manifold base part number. In
the case of complex arrangement, specify them on the manifold specification
sheet. For a manifold for an EX510, the length of the lead wire for a connector
assembly depends on the number of stations. Therefore, the manifold
assembly is shipped with the valves (including blanking plates) and connector
assembly mounted on it, as the standard specification. Be sure to specify the
part nos. of the solenoid valves to be mounted.
10
Symbol
N1
N3
N7
N9
N11
NM
VQZ1000
Port size

With one-touch fitting for ø1/8"
With one-touch fitting for ø5/32"
With one-touch fitting for ø1/4"


With one-touch fitting for ø5/16"
—



With one-touch fitting for ø3/8"
—
—
Mixture of port size






Base Mounted
Series VQZ1000/2000/3000
How to Order Valves
VQZ 1 1 5 1
5 M0
-Q
Series
1
2
3
VQZ1000
VQZ2000
VQZ3000
Type of actuation
1
2
3
4
5 Note 1)
8
9
Manual override
2 position single
-
Non-locking push type (Tool required)
2 position double
B
Locking type (Tool required)
3 position closed center
3 position exhaust center
3 position pressure center
3 port for mixture mounting N.C.
Electrical entry
3 port for mixture mounting N.O.
L0
M0
Note) Except VQZ1000 metal seal type.
Seal
0
1
M plug terminal without connector
Note 1) With light and surge voltage suppressor
Metal seal
Rubber seal
Function
Symbol
L plug terminal without connector
Rated voltage: 24 VDC
Specifications
-
Standard
K
Y
R
High pressure Note 1)
Low wattage type (0.5 W) Note 2)
External pilot Note 3)
Note 1) Metal seal only
Note 2) For an operation under continuous
energiging, use a low-watt type.
Note 3) Applicable to VQZ2000 and 3000.
11
Series VQZ1000/2000/3000
Dimensions/VQZ1000
119 (3 position)
110 (Double)
77 (Single: Metal)
75 (Single: Rubber)
52
62.5
Indicator light
The broken lines indicate the
DIN rail mounting style [-D].
M plug connector (M)
8.5
13.6
3.3
29
20
56
Indicator light
15.5 15.5
PE port
(30.5)
2 x 1/8
1(P) port
31
≈ 6.5
54
4 x 1/8
3(R2), 5(R1) port
L plug connector (L)
(11)
(7.5)
36
29
2n x C3, C4, C6
C3: One-touch fitting for ø3.2
C4: One-touch fitting for ø4
C6: One-touch fitting for ø6
14
(35)
(5.5)
(4.5)
6.5
4 x ø4.5 mounting hole
12
B
B
B
B
5
1
3
R1
P
R2
14
4
16.1
B
12
2
B
Stations
PWR
COM
1
A
4
A
A
2
A
3
(n-1) x 12
L2
L1
(L3)
4
A
(L4)
A
5
B
4
A
5
R1
A
6
1
P
Manual override
7
3
R2
n
2
B
Connector lock pin
DIN rail clamp screw
U side
D side
58
2n x M5
8 8
30.5
12
81 (Single: Rubber)
83 (Single: Metal)
131 (3 position)
For M5
Dimensions
n
L
L1
L2
L3
L4
17.7
14.5
2
B
4
A
122 (Double)
Maximum 16 stations
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
80
80
80
80
80
92
104
116
128
140
152
164
176
188
200
88
88
88
88
88
100
112
124
136
148
160
172
184
196
208
112.5
112.5
112.5
112.5
112.5
125
137.5
150
162.5
175
187.5
200
212.5
225
237.5
123
123
123
123
123
135.5
148
160.5
173
185.5
198
210.5
223
235.5
248
Note 1) “L” dimensions for 2 to 6 stations are the same. Valves are arranged from the “D” side.
12
Base Mounted
Series VQZ1000/2000/3000
Dimensions/VQZ2000
137.5 (3 position)
124.5 (Double)
The broken lines indicate the
DIN rail mounting style [-D].
92 (Single)
60.5
Indicator light
16
20
35
13.8
15.2
8
26
66.5
36.5
31.2
17
69.5
2 x M5 external pilot port
20
37.4
M plug connector (M)
Indicator light
≈ 11
66.5
20
20
2 x 1/4
1(P) port
13.8
15.2
5.3
20
63
External pilot specifications
4 x 1/4
(38)
31
≈ 11 3(R2), 5(R1) port
67
L plug connector (L)
2n x C4, C6, C8
C4: One-touch fitting for ø4
C6: One-touch fitting for ø6
C8: One-touch fitting for ø8
(12)
(7.5)
7.7
41
33
15
(35)
(2)
4 x ø4.5 mounting hole
(5.5)
DIN rail clamp screw
Connector lock pin
2
B
A
R1
5
Manual override
7
P
1
n
5
1
3
R1
P
R2
R2
3
4
U side
6
17
20.4 17
18
2
B
4
1
5
Stations
PWR
2
COM
A
3
(n-1) x 17
L2
L1
4
(L3)
(L4)
5
D side
10 10
2n x 1/8
66.5
38
23.9 17
136.5 (Double)
149.5 (3 position)
16.9
2
B
4
A
98 (Single)
For 1/8
Dimensions
n
L
L1
L2
L3
L4
Maximum 16 stations
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
94
94
94
94
111
128
145
162
179
196
213
230
247
264
281
104
104
104
104
121
138
155
172
189
206
223
240
257
274
291
125
125
125
125
150
162.5
175
200
212.5
237.5
250
262.5
287.5
300
312.5
135.5
135.5
135.5
135.5
160.5
173
185.5
210.5
223
248
260.5
273
298
310.5
323
Note 1) “L” dimensions for 2 ~ 5 stations are the same. Valves are arranged from the “D” side.
13
Series VQZ1000/2000/3000
Dimensions/VQZ3000
145 (3 position)
132 (Double)
102.5 (Single)
65
76.5
Indicator light
The broken lines indicate the
DIN rail mounting style [-D].
M plug connector (M)
21
PE port
(12)
(7.5)
9.4
50.5
41
19.5
(42)
31
2 x 3/8
1(P) port
2 x M5 external pilot port
(External pilot specification (R) only)
2n x C6, C8, C10
C6: One-touch fitting for ø6
C8: One-touch fitting for ø8
C10: One-touch fitting for ø10
21
26
20.5
19.1
20
37
9.2
(12)
69.5
(41)
Indicator light
4 x 1/4
3(R2), 5(R1) port
≈ 11
73
L plug connector (L)
(35)
(5.5)
4 x ø4.5 mounting hole
DIN rail clamp screw
Connector lock pin
U side
2
B
B
B
26
5
1
3
R1
P
R2
11
2
B
4
20
22.9 20
Stations
PWR
COM
1
A
SMC
A
2
B
A
3
(n-1) x 20
L2
L1
(L3)
4
A
(L4)
A
5
B
A
6
B
B
4
3
1
A
R2
P
Manual override
7
A
R1
5
n
D side
11.5
71
2n x 1/4
11.5
42
19.5
n
L1
L2
L3
L4
157 (3 position)
9.4
For 1/4
Dimensions
L
144 (Double)
19.2
26.6
2
B
4
A
20
108.5 (Single)
Maximum 16 stations
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
70
70
90
110
130
150
170
190
210
230
250
270
290
310
330
92
92
112
132
152
172
192
212
232
252
272
292
312
332
352
112.5
112.5
137.5
162.5
175
200
212.5
237.5
262.5
275
300
312.5
337.5
362.5
375
123
123
148
173
185.5
210.5
223
248
273
285.5
310.5
323
348
373
385.5
Note 1) “L” dimensions for 2 ~ 3 stations are the same. Valves are arranged from the “D” side.
14
Base Mounted
Series VQZ1000/2000/3000
Manifold Option
Blanking plate assembly
VVQZ1000-10A-5 (VQZ1000)
VVQZ2000-10A-5 (VQZ2000)
VVQZ3000-10A-5 (VQZ3000)
It is used by attaching on the manifold block for being
prepared for removing a valve for maintenance reasons
or planning to mount a spare valve, etc.
Throttle valve spacer (For VQZ2000 only)
VVQZ2000-20A-5
39.5
74.5
Mount a throttle valve spacer between manifold base
and valve, and thus making it possible to control cylinder
speed by meter-out.
Individual SUP spacer
M5 : VQZ1000
Rc1/8 : VQZ2000
Rc1/4 : VQZ3000
D
VVQZ1000-P-5-M5 (VQZ1000)
VVQZ2000-P-5-01 (VQZ2000)
VVQZ3000-P-5-02 (VQZ3000)
Supply port can be installed individually by mounting an
individual supply spacer onto the manifold block. It’s
used for such cases that the different pressure should be
supplied into each valve, etc.
A
B
C
Dimensions
A
B
VQZ1000 29 35
VQZ2000 33 43
VQZ3000 41 52
Note) For grommet
C
40
52
63
D Note)
67
81
93
C
40
52
63
D Note)
67
81
93
Individual EXH spacer
VVQZ1000-R-5-M5 (VQZ1000)
VVQZ2000-R-5-01 (VQZ2000)
VVQZ3000-R-5-02 (VQZ3000)
D
M5 : VQZ1000
Rc1/8 : VQZ2000
Rc1/4 : VQZ3000
Dimensions
A
B
C
Exhaust port can be installed individually by mounting an
individual exhaust spacer on to the manifold block. It’s
used for such cases that the valve exhaust is likely to
affect other stations due to circuit, etc.
A
B
VQZ1000 29 35
VQZ2000 33 43
VQZ3000 41 52
Note) For grommet
Port plug
VVQZ1000-CP (VQZ1000)
VVQZ2000-CP (VQZ2000)
VVQZ3000-CP (VQZ3000)
Used to block a cylinder port when changing 5 port
valves into 3 port valves, etc.
15
Series VQZ1000/2000/3000
Manifold Option
Connector assembly
For single solenoid (AXT661-81A-)
For double solenoid (AXT661-82A--)
(Red)
(Red)
A CB
A CB
A CB
(Black)
(Black)
Housing
Housing
How to Order Connector Assembly
(for a manifold with 8 stations or less with an unspecified layout)
Series
VV5QZ15
VV5QZ25
VV5QZ35
Assembly part no.
Connector mounting position
AXT661-81A-4
Single: for 1 to 8 stations
AXT661-82A-4-8
Double: for 1 to 8 stations
AXT661-81A-5
Single: for 1 to 8 stations
AXT661-82A-5-10
Double: for 1 to 8 stations
AXT661-81A-6
Single: for 1 to 8 stations
AXT661-82A-6-11
Double: for 1 to 8 stations
Note) Since these connector assemblies are used when adding stations or for maintenance, there are no part nos. on them.
Connector assembly
Housing (1 set 8 pieces)
AXT661-81-
SY3000-44-3A
(Red)
(+)
B C A
(–)
(–)
(+)
Triangular mark
Connector
(Black)
How to Order Connector Assembly
(for a manifold with a specified layout)
Series
VV5QZ15
VV5QZ25
VV5QZ35
Assembly part no.
Connector mounting position
AXT661-81-5
A side
AXT661-81-9
B side
AXT661-81-6
A side
AXT661-81-10
B side
AXT661-81-6
A side
AXT661-81-11
B side
AXT661-81-9
A side
AXT661-81-14
B side
AXT661-81-6
A side
AXT661-81-11
B side
AXT661-81-11
A side
AXT661-81-16
B side
For 1 to 8 stations
For 9 to 16 stations
For 1 to 8 stations
For 9 to 16 stations
For 1 to 8 stations
For 9 to 16 stations
Note 1) Since these connector assemblies are used when adding stations or for maintenance, there are no part nos. on them.
Note 2) After inserting the connector assembly into the housing, slightly pull the lead wire to make sure it does not pull out.
Do not reuse the lead wire once it has been inserted.
Note 3) Please note that the wires are longer than the actual wiring distance.
16

Similar documents

Product Overview

Product Overview IS1000E-20F01-X215 IS1000E-20F02-X215 IS1000E-20F03-X215 IS1000E-30F02-X215 IS1000E-30F03-X215 IS1000E-30F04-X215 IS1000E-40F02-X215 IS1000E-40F03-X215 IS1000E-40F04-X215 IS1000E-40F06-X215

More information

VQZ100/200/300

VQZ100/200/300 tests were performed on the axis and right angle direction of the main valve and armature, for both energized and de-energized states. (Value in the initial stage.) Vibration resistance: No malfunc...

More information

Series SQ1000/2000

Series SQ1000/2000 4 sets (Single solenoid part no.) 3 sets (Double solenoid part no.) 1 set (Blanking plate part no.)

More information