1 - SMC
Transcription
1 - SMC
Information 1-16-4 Shinbashi, Minato-ku, Tokyo 105-8659, JAPAN URL http://www.smcworld.com ©2005 SMC Corporation All Rights Reserved 04-EU515-UK Issued: June, 2005 D-DNP P-120 (DN) Serial Wiring 5 Port Solenoid Valve for EX510 Series VQZ Manifold Variations Body Ported A, B port size Piping with One-touch fitting Series Metric size ø3.2 ø4 ø6 Port piping Inch size ø8 ø10 ø1/8" ø5/32" ø1/4" ø5/16" ø3/8" M5 1/8 1/4 VQZ1000 VQZ2000 VQZ3000 Base Mounted A, B port size Piping with One-touch fitting Series Metric size ø3.2 ø4 ø6 Port piping Inch size ø8 ø10 ø1/8" ø5/32" ø1/4" ø5/16" ø3/8" M5 1/8 1/4 VQZ1000 VQZ2000 VQZ3000 Refer to Best Pneumatics catalogue for detailed specifications and precautions. 1 EX510 Serial Wiring Series VQZ1000/2000/3000 Body Ported How to Order Manifold VV5QZ 1 2 SA -Q 08 Manifold series 1 2 3 Option VQZ1000 VQZ2000 - SI unit COM. - +COM. N –COM. K Stations 2 stations ... ... 08 8 stations Note 1) Maximum 16 stations (For special wiring specifications) How to Order Valve Manifold Assembly (Example) Example VQZ2320-5L0-C6-Q Cylinder port size C6: With one-touch fitting for ø6 VQZ2220-5L0-C6-Q VQZ2120-5L0-C6-Q U 3 sid 1 e 6 7 5 0 1 ta ... S ... 1 ... 2 ... 3 ... 4 ... 5 ... 6 ... 7 n 14 15 R2 P R1 8 9 VV5QZ22-SA07-Q ns tio D e sid VV5QZ22-SA07-Q ∗ VQZ2120-5L0-C6-Q ∗ VQZ2220-5L0-C6-Q ∗ VQZ2320-5L0-C6-Q 1 set (Type SA, 7 station manifold base part no.) 2 sets (Single solenoid part no.) 3 sets (Double solenoid part no.) 2 sets (3 position type no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Enter in order starting from the first station on the D side. Add the valve and option part number under the manifold base part number. In the case of complex arrangement, specify them on the manifold specification sheet. For a manifold for an EX510, the length of the lead wire for a connector assembly depends on the number of stations. Therefore, the manifold assembly is shipped with the valves (including blanking plates) and connector assembly mounted on it, as the standard specification. Be sure to specify the part nos. of the solenoid valves to be mounted. 2 Special wiring specification (Except double wiring) Note) As for , enter the number from the DIN rail dimensions table on page 7. For L dimension, refer to the dimensions of each manifold on page 12 to 14. Symbol No. of stations 02 None With DIN rail (Rail length: Standard) D Without DIN rail (With bracket) D0 D Note) With DIN rail (Rail length: Special) VQZ3000 P, R thread type - Rc 00N 00T 00F NPT NPTF G Body Ported Series VQZ1000/2000/3000 How to Order Valve VQZ 1 1 2 1 Thread type Series 1 2 3 -Q C6 5 M0 VQZ1000 - Rc VQZ2000 N T F NPT VQZ3000 NPTF G Type of actuation 1 2 3 4 5 Note 1) 8 9 Manual override 2 position single 2 position double - Non-locking push type (Tool required) 3 position closed center B Locking type (Tool required) 3 position exhaust center Electrical entry 3 position pressure center L0 M0 3 port for mixture mounting N.C. 3 port for mixture mounting N.O. Seal Metal seal A, B port size Thread piping Rubber seal Symbol Function Symbol M plug terminal without connector Note 1) With light and surge voltage suppressor Note) Except VQZ1000 metal seal type. 0 1 L plug terminal without connector Specifications M5 02 - Standard Symbol High pressure Note 1) C3 C4 C6 C8 C10 External pilot Note 3) Note 1) Metal seal only Note 2) For an operation under continuous energiging, use a low-watt type. Note 3) Applicable to VQZ2000 and 3000. Rated voltage: 24 VDC VQZ1000 VQZ2000 VQZ3000 — 1/4 — — VQZ1000 VQZ2000 VQZ3000 — — — With one-touch fitting for ø6 With one-touch fitting for ø8 — — With one-touch fitting for ø10 — — One-touch fitting (Metric size) K Y R Low wattage type (0.5 W) Note 2) Port size M5 Port size With one-touch fitting for ø3.2 With one-touch fitting for ø4 One-touch fitting (Inch size) Symbol Port size VQZ1000 VQZ2000 VQZ3000 N1 N3 N7 N9 N11 With one-touch fitting for ø1/8" — — — With one-touch fitting for ø1/4" With one-touch fitting for ø5/16" — — With one-touch fitting for ø3/8" — — With one-touch fitting for ø5/32" 3 Series VQZ1000/2000/3000 Dimensions/VQZ1000 119 (3 position) 110 (Double) 77 (Single: Metal) Indicator light 75 (Single: Rubber) (20) 54.5 55 The broken lines indicate the DIN rail mounting style [-D]. ≈ 10 (For C3, C4, C6) M plug connector (M) PE port 12.5 (20) 48 46 (For M5) Indicator light 16.5 16.5 23.5 4 x 1/8 3(R2), 5(R1) port 31 2 x 1/8 1(P) port 49 L plug connector (L) 4 x ø4.5 mounting hole n x C3, C4, C6, M5 <4(A), 2(B) port> C3: One-touch fitting for ø3.2 C4: One-touch fitting for ø4 C6: One-touch fitting for ø6 M5: M5 thread (6) (35) (5.5) (DIN rail clamp screw) (11) 7.5 27.5 20 Connector lock pin U side n 3 R2 R1 P 5 1 8 2 2 2 2 2 3 2 2 1 (n-1) x 12 L3 L2 L1 4 L4 4 4 14 4 12 4 1 5 R1 P 3 R2 Stations 4 (5.25) PWR 4 COM 5 4 6 2 4 7 5.5 8.3 Manual override D side 5.5 8.3 81 (Single: Rubber) 83 (Single: Metal) 122 (Double) 131 (3 position) Dimensions n L L1 L2 L3 L4 Maximum 16 stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 80 80 80 80 80 92 104 116 128 140 152 164 176 188 200 88 88 88 88 88 100 112 124 136 148 160 172 184 196 208 112.5 112.5 112.5 112.5 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225 237.5 123 123 123 123 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 Note 1) “L” dimensions for 2 ~ 6 stations are the same. Valves are arranged from the “D” side. 4 Body Ported Series VQZ1000/2000/3000 Dimensions/VQZ2000 137.5 (3 position) 124.5 (Double) 92 (Single) 62 (20) 64.3 Indicator light The broken lines indicate the DIN rail mounting style [-D]. 11.5 16.5 (20) 52 58 (For M5) ≈ 10 (For C4, C6) M plug connector (M) Indicator light PE port 21 21 2 x 1/4 1(P) port 4 x 1/4 3(R2), 5(R1) port 60 31 L plug connector (L) 4 x ø4.5 mounting hole n x C4, C6, M5 <4(A), 2(B) port> C4: One-touch fitting for ø4 C6: One-touch fitting for ø6 M5: M5 thread (35) (5.5) (DIN rail clamp screw) (11) 34.5 27 (7.5) U side n Connector lock pin P R2 1 3 R1 5 4 B 8 4 B A 2 7 B B 2 A 2 4 4 B L1 (n-1) x 17 4 L3 5 A L2 4 L4 A 2 6 4 B A 2 3 2 4 B 17 A 2 A 18 1 5 1 3 R1 P R2 5 Stations D side 66 Manual override (5.25) PWR COM 2 10.25 10.25 98 (Single) 136.5 (Double) 149.5 (3 position) Dimensions n L L1 L2 L3 L4 Maximum 16 stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 94 94 94 94 111 128 145 162 179 196 213 230 247 264 281 104 104 104 104 121 138 155 172 189 206 223 240 257 274 291 125 125 125 125 150 162.5 175 200 212.5 237.5 250 262.5 287.5 300 312.5 135.5 135.5 135.5 135.5 160.5 173 185.5 210.5 223 248 260.5 273 298 310.5 323 Note 1) “L” dimensions for 2 to 5 stations are the same. Valves are arranged from the “D” side. 5 Series VQZ1000/2000/3000 Dimensions/VQZ3000 145 (3 position) 132 (Double) 102.5 (Single) (20) 64 Indicator light 21 21 31 PE port 11.5 16.5 (20) 57 65.5 Indicator light 60 2 x 1/4 1(P) port L plug connector (L) (35) (5.5) 4 x ø4.5 mounting hole (DIN rail clamp screw) n x C6, C8, C10, 02 <4(A), 2(B) port> C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 C10: One-touch fitting for ø10 02: 1/4 (4) 36 27 (11) (7.5) Connector lock pin U side n 5 R1 4 x 1/4 3(R2), 5(R1) port (For 02) ≈ 10.5 (For C6, C8) M plug connector (M) ≈ 17.5 (For C10) The broken lines indicate the DIN rail mounting style [-D]. 3 R2 P 1 8 2 A 4 A 2 B 7 2 B 2 4 4 A 2 B L1 (n-1) x 20 A L2 5 4 L4 A L3 4 B 6 4 2 2 A B 1 PWR P COM 4 26 2 B 4 20 A 1 3 R2 11 B 3 5 R1 Stations D side (5.25) Manual override 9 9 10.25 10.25 108.5 (Single) 144 (Double) 157 (3 position) Dimensions n L L1 L2 L3 L4 Maximum 16 stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 70 70 90 110 130 150 170 190 210 230 250 270 290 310 330 92 92 112 132 152 172 192 212 232 252 272 292 312 332 352 112.5 112.5 137.5 162.5 175 200 212.5 237.5 262.5 275 300 312.5 337.5 362.5 375 123 123 148 173 185.5 210.5 223 248 273 285.5 310.5 323 348 373 385.5 Note 1) “L” dimensions for 2 to 3 stations are the same. Valves are arranged from the “D” side. 6 Body Ported Series VQZ1000/2000/3000 Manifold Option Blanking plate assembly VVQZ1000-10A-2 (VQZ1000) VVQZ2000-10A-2 (VQZ2000) VVQZ3000-10A-2 (VQZ3000) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. L DIN rail 12.5 5.25 (Pitch) AXT100-DR- Each manifold can be mounted on a DIN rail. Order it by indicating an option symbol for DIN rail mounting style, -D. The DIN rail is approximately 30 mm longer than the length of manifold. 5.5 35 25 ∗ As for , enter the number from the DIN rail dimensions table. For L dimension, refer to the dimensions of each manifold. 7.5 1.25 L Dimension L = 12.5n + 10.5 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L dimension 23 35.5 48 60.5 73 85.5 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 No. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 L dimension 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 Blanking plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 L A øD Dimensions Color: White Applicable fittings size ød Model A L D 3.2 4 6 8 10 KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 Silencer (For Manifold EXH port) 63 Silencer is installed in the EXH port. ø22 38 ø13 Dimensions AN110-01 Model AN200-02 VQZ1000 VQZ2000 VQZ3000 Silencer P/N AN110-01 AN200-02 AN200-02 For a silencer to be mounted in a single valve unit, refer to Best Pneumatics catalogue. Port plug VVQZ100-CP (VQZ1000/ VQZ2000) VVQZ2000-CP (VQZ3000) Used to block a cylinder port when changing 5 port valves into 3 port valves, etc. 7 Series VQZ1000/2000/3000 Manifold Option Connector assembly For single solenoid (AXT661-81A-) For double solenoid (AXT661-82A--) (Red) (Red) A CB A CB A CB (Black) (Black) Housing Housing How to Order Connector Assembly (for a manifold with 8 stations or less with an unspecified layout) Series VV5QZ12 VV5QZ22 VV5QZ32 Assembly part no. Connector mounting position AXT661-81A-4 Single: for 1 to 8 stations AXT661-82A-4-8 Double: for 11 to 8 stations AXT661-81A-5 Single: for 11 to 8 stations AXT661-82A-5-10 Double: for 11 to 8 stations AXT661-81A-6 Single: for 11 to 8 stations AXT661-82A-6-11 Double: for 11 to 8 stations Note) Since these connector assemblies are used when adding stations or for maintenance, there are no part nos. on them. Connector assembly Housing (1 set 8 pieces) AXT661-81- SY3000-44-3A (Red) (+) B C A (–) (–) (+) Triangular mark Connector (Black) How to Order Connector Assembly (for a manifold with a specified layout) Series VV5QZ12 VV5QZ22 VV5QZ32 Assembly part no. Connector mounting position AXT661-81-5 A side AXT661-81-9 B side AXT661-81-6 A side AXT661-81-10 B side AXT661-81-6 A side AXT661-81-11 B side AXT661-81-9 A side AXT661-81-14 B side AXT661-81-6 A side AXT661-81-11 B side AXT661-81-11 A side AXT661-81-16 B side For 1 to 8 stations For 9 to 16 stations For 1 to 8 stations For 9 to 16 stations For 1 to 8 stations For 9 to 16 stations Note 1) Since these connector assemblies are used when adding stations or for maintenance, there are no part nos. on them. Note 2) After inserting the connector assembly into the housing, slightly pull the lead wire to make sure it does not pull out. Do not reuse the lead wire once it has been inserted. Note 3) Please note that the wires are longer than the actual wiring distance. 8 9 EX510 Serial Wiring Series VQZ1000/2000/3000 Base Mounted How to Order Manifold VV5QZ 1 5 SA -Q 08 C4 Option Manifold series 1 2 3 VQZ1000 - VQZ2000 D D0 D VQZ3000 SI unit COM. - +COM. N –COM. Without DIN rail (With bracket) With DIN rail (Rail length: Special) Note 1) Applicable to VQZ2000 and 3000. Thread type Symbol No. of stations 2 stations ... ... 08 With DIN rail (Rail length: Standard) N Note 1) With label plate Special wiring specification (Except double wiring) K R Note 1) External pilot Stations 02 None 8 stations Note 1) Maximum 16 stations (For special wiring specifications) - Rc N T F NPT G A, B port size Thread piping VQZ1000 VQZ2000 VQZ3000 M5 — — 1/8 — — 1/4 — — VQZ1000 VQZ2000 VQZ3000 — — With one-touch fitting for ø8 — — With one-touch fitting for ø6 With one-touch fitting for ø10 — — Mixture of port size VQZ2000 VQZ3000 — — — Port size Symbol How to Order Valve Manifold Assembly (Example) NPTF M5 01 02 One-touch fitting (Metric size) Example VQZ2350-5L0-Q VQZ2250-5L0-Q VQZ2150-5L0-Q Symbol C3 C4 C6 C8 C10 CM Port size With one-touch fitting for ø3.2 With one-touch fitting for ø4 One-touch fitting (Inch size) 3 U sid 1 e 6 7 5 0 1 ... S ... 1 ... 2 ... 3 ... 4 ... 5 ... 6 ... 7 n 14 15 R2 P R1 8 9 VV5QZ25-SA07C6-Q ns tio ta D e sid VV5QZ25-SA07C6-Q ∗ VQZ2150-5L0-Q ∗ VQZ2250-5L0-Q ∗ VQZ2350-5L0-Q 1 set (Type SA, 7 station manifold base part no.) 2 sets (Single solenoid part no.) 3 sets (Double solenoid part no.) 2 sets (3 position type no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Enter in order starting from the first station on the D side. Add the valve and option part number under the manifold base part number. In the case of complex arrangement, specify them on the manifold specification sheet. For a manifold for an EX510, the length of the lead wire for a connector assembly depends on the number of stations. Therefore, the manifold assembly is shipped with the valves (including blanking plates) and connector assembly mounted on it, as the standard specification. Be sure to specify the part nos. of the solenoid valves to be mounted. 10 Symbol N1 N3 N7 N9 N11 NM VQZ1000 Port size With one-touch fitting for ø1/8" With one-touch fitting for ø5/32" With one-touch fitting for ø1/4" With one-touch fitting for ø5/16" — With one-touch fitting for ø3/8" — — Mixture of port size Base Mounted Series VQZ1000/2000/3000 How to Order Valves VQZ 1 1 5 1 5 M0 -Q Series 1 2 3 VQZ1000 VQZ2000 VQZ3000 Type of actuation 1 2 3 4 5 Note 1) 8 9 Manual override 2 position single - Non-locking push type (Tool required) 2 position double B Locking type (Tool required) 3 position closed center 3 position exhaust center 3 position pressure center 3 port for mixture mounting N.C. Electrical entry 3 port for mixture mounting N.O. L0 M0 Note) Except VQZ1000 metal seal type. Seal 0 1 M plug terminal without connector Note 1) With light and surge voltage suppressor Metal seal Rubber seal Function Symbol L plug terminal without connector Rated voltage: 24 VDC Specifications - Standard K Y R High pressure Note 1) Low wattage type (0.5 W) Note 2) External pilot Note 3) Note 1) Metal seal only Note 2) For an operation under continuous energiging, use a low-watt type. Note 3) Applicable to VQZ2000 and 3000. 11 Series VQZ1000/2000/3000 Dimensions/VQZ1000 119 (3 position) 110 (Double) 77 (Single: Metal) 75 (Single: Rubber) 52 62.5 Indicator light The broken lines indicate the DIN rail mounting style [-D]. M plug connector (M) 8.5 13.6 3.3 29 20 56 Indicator light 15.5 15.5 PE port (30.5) 2 x 1/8 1(P) port 31 ≈ 6.5 54 4 x 1/8 3(R2), 5(R1) port L plug connector (L) (11) (7.5) 36 29 2n x C3, C4, C6 C3: One-touch fitting for ø3.2 C4: One-touch fitting for ø4 C6: One-touch fitting for ø6 14 (35) (5.5) (4.5) 6.5 4 x ø4.5 mounting hole 12 B B B B 5 1 3 R1 P R2 14 4 16.1 B 12 2 B Stations PWR COM 1 A 4 A A 2 A 3 (n-1) x 12 L2 L1 (L3) 4 A (L4) A 5 B 4 A 5 R1 A 6 1 P Manual override 7 3 R2 n 2 B Connector lock pin DIN rail clamp screw U side D side 58 2n x M5 8 8 30.5 12 81 (Single: Rubber) 83 (Single: Metal) 131 (3 position) For M5 Dimensions n L L1 L2 L3 L4 17.7 14.5 2 B 4 A 122 (Double) Maximum 16 stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 80 80 80 80 80 92 104 116 128 140 152 164 176 188 200 88 88 88 88 88 100 112 124 136 148 160 172 184 196 208 112.5 112.5 112.5 112.5 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225 237.5 123 123 123 123 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 Note 1) “L” dimensions for 2 to 6 stations are the same. Valves are arranged from the “D” side. 12 Base Mounted Series VQZ1000/2000/3000 Dimensions/VQZ2000 137.5 (3 position) 124.5 (Double) The broken lines indicate the DIN rail mounting style [-D]. 92 (Single) 60.5 Indicator light 16 20 35 13.8 15.2 8 26 66.5 36.5 31.2 17 69.5 2 x M5 external pilot port 20 37.4 M plug connector (M) Indicator light ≈ 11 66.5 20 20 2 x 1/4 1(P) port 13.8 15.2 5.3 20 63 External pilot specifications 4 x 1/4 (38) 31 ≈ 11 3(R2), 5(R1) port 67 L plug connector (L) 2n x C4, C6, C8 C4: One-touch fitting for ø4 C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 (12) (7.5) 7.7 41 33 15 (35) (2) 4 x ø4.5 mounting hole (5.5) DIN rail clamp screw Connector lock pin 2 B A R1 5 Manual override 7 P 1 n 5 1 3 R1 P R2 R2 3 4 U side 6 17 20.4 17 18 2 B 4 1 5 Stations PWR 2 COM A 3 (n-1) x 17 L2 L1 4 (L3) (L4) 5 D side 10 10 2n x 1/8 66.5 38 23.9 17 136.5 (Double) 149.5 (3 position) 16.9 2 B 4 A 98 (Single) For 1/8 Dimensions n L L1 L2 L3 L4 Maximum 16 stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 94 94 94 94 111 128 145 162 179 196 213 230 247 264 281 104 104 104 104 121 138 155 172 189 206 223 240 257 274 291 125 125 125 125 150 162.5 175 200 212.5 237.5 250 262.5 287.5 300 312.5 135.5 135.5 135.5 135.5 160.5 173 185.5 210.5 223 248 260.5 273 298 310.5 323 Note 1) “L” dimensions for 2 ~ 5 stations are the same. Valves are arranged from the “D” side. 13 Series VQZ1000/2000/3000 Dimensions/VQZ3000 145 (3 position) 132 (Double) 102.5 (Single) 65 76.5 Indicator light The broken lines indicate the DIN rail mounting style [-D]. M plug connector (M) 21 PE port (12) (7.5) 9.4 50.5 41 19.5 (42) 31 2 x 3/8 1(P) port 2 x M5 external pilot port (External pilot specification (R) only) 2n x C6, C8, C10 C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 C10: One-touch fitting for ø10 21 26 20.5 19.1 20 37 9.2 (12) 69.5 (41) Indicator light 4 x 1/4 3(R2), 5(R1) port ≈ 11 73 L plug connector (L) (35) (5.5) 4 x ø4.5 mounting hole DIN rail clamp screw Connector lock pin U side 2 B B B 26 5 1 3 R1 P R2 11 2 B 4 20 22.9 20 Stations PWR COM 1 A SMC A 2 B A 3 (n-1) x 20 L2 L1 (L3) 4 A (L4) A 5 B A 6 B B 4 3 1 A R2 P Manual override 7 A R1 5 n D side 11.5 71 2n x 1/4 11.5 42 19.5 n L1 L2 L3 L4 157 (3 position) 9.4 For 1/4 Dimensions L 144 (Double) 19.2 26.6 2 B 4 A 20 108.5 (Single) Maximum 16 stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 70 70 90 110 130 150 170 190 210 230 250 270 290 310 330 92 92 112 132 152 172 192 212 232 252 272 292 312 332 352 112.5 112.5 137.5 162.5 175 200 212.5 237.5 262.5 275 300 312.5 337.5 362.5 375 123 123 148 173 185.5 210.5 223 248 273 285.5 310.5 323 348 373 385.5 Note 1) “L” dimensions for 2 ~ 3 stations are the same. Valves are arranged from the “D” side. 14 Base Mounted Series VQZ1000/2000/3000 Manifold Option Blanking plate assembly VVQZ1000-10A-5 (VQZ1000) VVQZ2000-10A-5 (VQZ2000) VVQZ3000-10A-5 (VQZ3000) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. Throttle valve spacer (For VQZ2000 only) VVQZ2000-20A-5 39.5 74.5 Mount a throttle valve spacer between manifold base and valve, and thus making it possible to control cylinder speed by meter-out. Individual SUP spacer M5 : VQZ1000 Rc1/8 : VQZ2000 Rc1/4 : VQZ3000 D VVQZ1000-P-5-M5 (VQZ1000) VVQZ2000-P-5-01 (VQZ2000) VVQZ3000-P-5-02 (VQZ3000) Supply port can be installed individually by mounting an individual supply spacer onto the manifold block. It’s used for such cases that the different pressure should be supplied into each valve, etc. A B C Dimensions A B VQZ1000 29 35 VQZ2000 33 43 VQZ3000 41 52 Note) For grommet C 40 52 63 D Note) 67 81 93 C 40 52 63 D Note) 67 81 93 Individual EXH spacer VVQZ1000-R-5-M5 (VQZ1000) VVQZ2000-R-5-01 (VQZ2000) VVQZ3000-R-5-02 (VQZ3000) D M5 : VQZ1000 Rc1/8 : VQZ2000 Rc1/4 : VQZ3000 Dimensions A B C Exhaust port can be installed individually by mounting an individual exhaust spacer on to the manifold block. It’s used for such cases that the valve exhaust is likely to affect other stations due to circuit, etc. A B VQZ1000 29 35 VQZ2000 33 43 VQZ3000 41 52 Note) For grommet Port plug VVQZ1000-CP (VQZ1000) VVQZ2000-CP (VQZ2000) VVQZ3000-CP (VQZ3000) Used to block a cylinder port when changing 5 port valves into 3 port valves, etc. 15 Series VQZ1000/2000/3000 Manifold Option Connector assembly For single solenoid (AXT661-81A-) For double solenoid (AXT661-82A--) (Red) (Red) A CB A CB A CB (Black) (Black) Housing Housing How to Order Connector Assembly (for a manifold with 8 stations or less with an unspecified layout) Series VV5QZ15 VV5QZ25 VV5QZ35 Assembly part no. Connector mounting position AXT661-81A-4 Single: for 1 to 8 stations AXT661-82A-4-8 Double: for 1 to 8 stations AXT661-81A-5 Single: for 1 to 8 stations AXT661-82A-5-10 Double: for 1 to 8 stations AXT661-81A-6 Single: for 1 to 8 stations AXT661-82A-6-11 Double: for 1 to 8 stations Note) Since these connector assemblies are used when adding stations or for maintenance, there are no part nos. on them. Connector assembly Housing (1 set 8 pieces) AXT661-81- SY3000-44-3A (Red) (+) B C A (–) (–) (+) Triangular mark Connector (Black) How to Order Connector Assembly (for a manifold with a specified layout) Series VV5QZ15 VV5QZ25 VV5QZ35 Assembly part no. Connector mounting position AXT661-81-5 A side AXT661-81-9 B side AXT661-81-6 A side AXT661-81-10 B side AXT661-81-6 A side AXT661-81-11 B side AXT661-81-9 A side AXT661-81-14 B side AXT661-81-6 A side AXT661-81-11 B side AXT661-81-11 A side AXT661-81-16 B side For 1 to 8 stations For 9 to 16 stations For 1 to 8 stations For 9 to 16 stations For 1 to 8 stations For 9 to 16 stations Note 1) Since these connector assemblies are used when adding stations or for maintenance, there are no part nos. on them. Note 2) After inserting the connector assembly into the housing, slightly pull the lead wire to make sure it does not pull out. Do not reuse the lead wire once it has been inserted. Note 3) Please note that the wires are longer than the actual wiring distance. 16
Similar documents
Product Overview
IS1000E-20F01-X215 IS1000E-20F02-X215 IS1000E-20F03-X215 IS1000E-30F02-X215 IS1000E-30F03-X215 IS1000E-30F04-X215 IS1000E-40F02-X215 IS1000E-40F03-X215 IS1000E-40F04-X215 IS1000E-40F06-X215
More informationVQZ100/200/300
tests were performed on the axis and right angle direction of the main valve and armature, for both energized and de-energized states. (Value in the initial stage.) Vibration resistance: No malfunc...
More informationSeries SQ1000/2000
4 sets (Single solenoid part no.) 3 sets (Double solenoid part no.) 1 set (Blanking plate part no.)
More information