Haskris Brochure (revised December-02)

Transcription

Haskris Brochure (revised December-02)
Water
Recirculating
Systems
Haskris water recirculating systems are designed to provide a continuous supply of clean,
temperature controlled fluid to your water cooled equipment.
Haskris specializes in custom designs. Please contact us
to discuss your special requirements and let us design a
system tailored to your application.
click on
Refrigerated Models
100 Kelly Street, Elk Grove Village, IL 60007, Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
Non - Refrigerated Models
click for home page
Refrigerated Water Recirculating Systems
100 Kelly Street, Elk Grove Village, IL 60007, Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
Model
Cooling Capacity
Details
R033
Up Up
To To
1200 Watts (4090 Btu/Hr)
Click Button For Tech Specs
R050
Up Up
To To
1750 Watts (5970 Btu/Hr)
Click Button For Tech Specs
R075
UpUp
ToTo
3000 Watts (10,230 Btu/Hr)
Click Button For Tech Specs
R100
UpUp
ToTo
3850 Watts (13,125 Btu/Hr)
Click Button For Tech Specs
R175
UpUp
ToTo
6500 Watts (22,165 Btu/Hr)
Click Button For Tech Specs
R250
UpUp
To To
8500Watts (28,985 Btu/Hr)
Click Button For Tech Specs
R300
Up
UpTo
To
11,000 Watts (37,510 Btu/Hr)
Click Button For Tech Specs
R400
UpTo
To
Up
13,500 Watts (46,025 Btu/Hr)
Click Button For Tech Specs
R500
UpTo
To
Up
17,000 Watts (57,975 Btu/Hr)
Click Button For Tech Specs
R550
UpTo
To
Up
19,500 Watts (66,500 Btu/Hr)
Click Button For Tech Specs
R750
Up
UpTo
To
25,000 Watts (85,250 Btu/Hr)
Click Button For Tech Specs
R1000
Up To
33,000 Watts (112,530 Btu/Hr)
Click Button For Tech Specs
click for home page
Model R033
100 Kelly Street, Elk Grove Village, IL 60007
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
with air cooled condenser
Cooling Capacity
( at 65°F supply water temp. )
Compressor HP
Refrigerant
Water Pump Capacity
several alternatives
available
Pump Motor HP
Reservoir Volume
Power Requirements*
Dimensions
several alternatives
available
( W x D x H ) in.
Shipping Weight
Refrigerated Water Recirculating Systems
Watts
Btu/Hr
950
3,240
with water cooled condenser
Watts
Btu/Hr
1,200
4,090
1/3
1/3
R134a
R134a
1 GPM (3.8 LPM)
1 GPM (3.8 LPM)
1/3
1/3
5 Gallons (19 Liters)
5 Gallons (19 Liters)
115V-1
-60Hz
115V-1
-60Hz
18 x 27 x 29
18 x 27 x 29
250 Lbs. (113 Kgs.)
250 Lbs. (113 Kgs.)
• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.
• Unit specifications will change by adding certain options.
* Also available in 50Hz
Available Options
c l i c k
Similar Models (Click)
Custom Design
c l i c k
Non - Refrigerated Models
c l i c k
R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000
click for home page
Model R050
Refrigerated Water Recirculating Systems
100 Kelly Street, Elk Grove Village, IL 60007
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
with air cooled condenser
Cooling Capacity
Watts
Btu/Hr
( at 65°F supply water temp. )
Compressor HP
several alternatives
available
Power Requirements*
Dimensions
several alternatives
available
( W x D x H ) in.
Shipping Weight
115V-1
1,750
5,970
1/2
R134a
R134a
1 GPM (3.8 LPM)
1 GPM (3.8 LPM)
1/3
1/3
5 Gallons (19 Liters)
5 Gallons (19 Liters)
Pump Motor HP
Reservoir Volume
Watts
Btu/Hr
1,400
4,775
1/2
Refrigerant
Water Pump Capacity
with water cooled condenser
-60HZ
or
208/230V-1
-60Hz
115V-1
-60HZ
or
208/230V-1
18 x 27 x 29
18 x 27 x 29
250 Lbs. (113 Kgs.)
250 Lbs. (113 Kgs.)
-60Hz
• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.
• Unit specifications will change by adding certain options.
* Also available in 50Hz
Available Options
c l i c k
Similar Models (Click)
Custom Design
c l i c k
Non - Refrigerated Models
c l i c k
R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000
click for home page
Model R075
100 Kelly Street, Elk Grove Village, IL 60007
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
with air cooled condenser
Cooling Capacity
( at 65°F supply water temp. )
Compressor HP
Refrigerant
Water Pump Capacity
several alternatives
available
Pump Motor HP
Reservoir Volume
Power Requirements*
Dimensions
several alternatives
available
( W x D x H ) in.
Shipping Weight
Refrigerated Water Recirculating Systems
Watts
Btu/Hr
2,200
7,500
with water cooled condenser
Watts
3,000
Btu/Hr 10,230
3/4
3/4
R134a
R134a
1.7 GPM (6.4 LPM)
1.7 GPM (6.4 LPM)
1/3
1/3
6 Gallons (23 Liters)
6 Gallons (23 Liters)
208/230V-1
208/230V-1
-60Hz
-60Hz
21 x 29 x 32
21 x 29 x 32
350 Lbs. (159 Kgs.)
350 Lbs. (159 Kgs.)
• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.
• Unit specifications will change by adding certain options.
* Also available in 50Hz
Available Options
c l i c k
Similar Models (Click)
Custom Design
c l i c k
Non - Refrigerated Models
c l i c k
R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000
click for home page
Model R100
100 Kelly Street, Elk Grove Village, IL 60007
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
with air cooled condenser
Cooling Capacity
( at 65°F supply water temp. )
Compressor HP
Refrigerant
Water Pump Capacity
several alternatives
available
Pump Motor HP
Reservoir Volume
Power Requirements*
Dimensions
several alternatives
available
( W x D x H ) in.
Shipping Weight
Refrigerated Water Recirculating Systems
Watts
Btu/Hr
3,150
10,740
with water cooled condenser
Watts
3,850
Btu/Hr 13,125
1
1
R134a
R134a
1.7 GPM (6.4 LPM)
1.7 GPM (6.4 LPM)
1/3
1/3
6 Gallons (23 Liters)
6 Gallons (23 Liters)
208/230V-1
208/230V-1
-60Hz
-60Hz
21 x 29 x 32
21 x 29 x 32
350 Lbs. (159 Kgs.)
350 Lbs. (159 Kgs.)
• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.
• Unit specifications will change by adding certain options.
* Also available in 50Hz
Available Options
c l i c k
Similar Models (Click)
Custom Design
c l i c k
Non - Refrigerated Models
c l i c k
R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000
click for home page
Model R175
100 Kelly Street, Elk Grove Village, IL 60007
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
with air cooled condenser
Cooling Capacity
( at 65°F supply water temp. )
Refrigerated Water Recirculating Systems
Watts
Btu/Hr
5,500
18,750
with water cooled condenser
Watts
6,500
Btu/Hr 22,165
Compressor HP
1.75
1.75
Refrigerant
R22
R22
3.7 GPM (14.1 LPM)
3.7 GPM (14.1 LPM)
1/3
1/3
9 Gallon (34 Liters)
9 Gallon (34 Liters)
Water Pump Capacity
several alternatives
available
Pump Motor HP
Reservoir Volume
Power Requirements*
Dimensions
several alternatives
available
( W x D x H ) in.
Shipping Weight
208/230V-1
-60Hz
208/230V-1
-60Hz
27 x 26 x 35
27 x 26 x 35
425 Lbs. (193 Kgs.)
425 Lbs. (193 Kgs.)
• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.
• Unit specifications will change by adding certain options.
* Also available in 50Hz
Available Options
c l i c k
Similar Models (Click)
Custom Design
c l i c k
Non - Refrigerated Models
c l i c k
R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000
click for home page
Model R250
Refrigerated Water Recirculating Systems
100 Kelly Street, Elk Grove Village, IL 60007
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
with air cooled condenser
Cooling Capacity
Watts
Btu/Hr
( at 65°F supply water temp. )
with water cooled condenser
Watts
8,500
Btu/Hr 28,985
7,500
25,575
Compressor HP
2.5
2.5
Refrigerant
R22
R22
3.7 GPM (14.1 LPM)
3.7 GPM (14.1 LPM)
1/3
1/3
14 Gallons (53 Liters)
14 Gallons (53 Liters)
Water Pump Capacity
several alternatives
available
Pump Motor HP
Reservoir Volume
Power Requirements*
Dimensions
several alternatives
available
( W x D x H ) in.
Shipping Weight
208/230V-1
-60Hz
or
208/230V-3
-60Hz
208/230V-1
-60Hz
or
208/230V-3
35 x 31 x 48
27 x 26 x 43
750 Lbs. (340 Kgs.)
525Lbs. (238 Kgs.)
-60Hz
• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.
• Unit specifications will change by adding certain options.
* Also available in 50Hz
Available Options
c l i c k
Similar Models (Click)
Custom Design
c l i c k
Non - Refrigerated Models
c l i c k
R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000
click for home page
Model R300
Refrigerated Water Recirculating Systems
100 Kelly Street, Elk Grove Village, IL 60007
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
with air cooled condenser
Cooling Capacity
Watts
Btu/Hr
( at 65°F supply water temp. )
Compressor HP
several alternatives
available
3
R22
R22
7.9 GPM (30.0 LPM)
7.9 GPM (30.0 LPM)
3/4
3/4
14 Gallons (53 Liters)
14 Gallons (53 Liters)
Pump Motor HP
Reservoir Volume
Power Requirements*
Dimensions
several alternatives
available
( W x D x H ) in.
Shipping Weight
208/230V-1
Watts 11,000
Btu/Hr 37,510
10,000
34,100
3
Refrigerant
Water Pump Capacity
with water cooled condenser
-60Hz
or
208/230V-3
-60Hz
208/230V-1
-60Hz
or
208/230V-3
35 x 31 x 48
30 x 26 x 43
750 Lbs. (340 Kgs.)
600 Lbs. (272 Kgs.)
-60Hz
• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.
• Unit specifications will change by adding certain options.
* Also available in 50Hz
Available Options
c l i c k
Similar Models (Click)
Custom Design
c l i c k
Non - Refrigerated Models
c l i c k
R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000
click for home page
Model R400
100 Kelly Street, Elk Grove Village, IL 60007
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
with air cooled condenser
Cooling Capacity
( at 65°F supply water temp. )
Compressor HP
Refrigerant
Water Pump Capacity
several alternatives
available
Pump Motor HP
Reservoir Volume
Power Requirements*
Dimensions
several alternatives
available
( W x D x H ) in.
Shipping Weight
Refrigerated Water Recirculating Systems
Watts
Btu/Hr
12,500
42,625
with water cooled condenser
Watts 13,500
Btu/Hr 46,025
4
4
R22
R22
7.9 GPM (30.0 LPM)
7.9 GPM (30.0 LPM)
3/4
3/4
30 Gallons (114 Liters)
30 Gallons (114 Liters)
208/230V-3
-60Hz
208/230V-3
-60Hz
47 x 36 x 56
30 x 36 x 48
900 Lbs. (408 Kgs.)
600 Lbs. (272 Kgs.)
• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.
• Unit specifications will change by adding certain options.
* Also available in 50Hz
Available Options
c l i c k
Similar Models (Click)
Custom Design
c l i c k
Non - Refrigerated Models
c l i c k
R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000
click for home page
Model R500
Refrigerated Water Recirculating Systems
100 Kelly Street, Elk Grove Village, IL 60007
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
with air cooled condenser
Cooling Capacity
Watts
Btu/Hr
( at 65°F supply water temp. )
Compressor HP
several alternatives
available
5
R22
R22
9 GPM (34.2 LPM)
9 GPM (34.2 LPM)
1
1
30 Gallons (114 Liters)
30 Gallons (114 Liters)
Pump Motor HP
Reservoir Volume
Power Requirements*
Dimensions
several alternatives
available
( W x D x H ) in.
Shipping Weight
Watts 17,000
Btu/Hr 57,975
15,500
52,850
5
Refrigerant
Water Pump Capacity
with water cooled condenser
208/230V-3
-60Hz
or
460V-3
-60Hz
208/230V-3
-60Hz
or
460V-3
47 x 36 x 56
30 x 36 x 48
900 Lbs. (408 Kgs.)
650 Lbs. (295Kgs.)
-60Hz
• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.
• Unit specifications will change by adding certain options.
* Also available in 50Hz
Available Options
c l i c k
Similar Models (Click)
Custom Design
c l i c k
Non - Refrigerated Models
c l i c k
R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000
click for home page
Model R550
Refrigerated Water Recirculating Systems
100 Kelly Street, Elk Grove Village, IL 60007
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
with air cooled condenser
Cooling Capacity
Watts
Btu/Hr
( at 65°F supply water temp. )
with water cooled condenser
Watts 19,500
Btu/Hr 66,500
18,000
61,375
Compressor HP
5.5
5.5
Refrigerant
R22
R22
9 GPM (34.2 LPM)
9 GPM (34.2 LPM)
1
1
30 Gallons (114 Liters)
30 Gallons (114 Liters)
Water Pump Capacity
several alternatives
available
Pump Motor HP
Reservoir Volume
Power Requirements*
Dimensions
several alternatives
available
( W x D x H ) in.
Shipping Weight
208/230V-3
-60Hz
or
460V-3
-60Hz
208/230V-3
-60Hz
or
460V-3
47 x 36 x 56
30 x 36 x 48
900 Lbs. (408 Kgs.)
650 Lbs. (295 Kgs.)
-60Hz
• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.
• Unit specifications will change by adding certain options.
* Also available in 50Hz
Available Options
c l i c k
Similar Models (Click)
Custom Design
c l i c k
Non - Refrigerated Models
c l i c k
R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000
click for home page
Model R750
Refrigerated Water Recirculating Systems
100 Kelly Street, Elk Grove Village, IL 60007
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
with air cooled condenser
Cooling Capacity
Watts
Btu/Hr
( at 65°F supply water temp. )
with water cooled condenser
Watts 25,000
Btu/Hr 85,250
23,000
78,425
Compressor HP
7.5
7.5
Refrigerant
R22
R22
12.5 GPM (47.5 LPM)
12.5 GPM (47.5 LPM)
1.5
1.5
30 Gallons (114 Liters)
30 Gallons (114 Liters)
Water Pump Capacity
several alternatives
available
Pump Motor HP
Reservoir Volume
Power Requirements*
Dimensions
several alternatives
available
( W x D x H ) in.
Shipping Weight
208/230V-3
-60Hz
or
460V-3
-60Hz
208/230V-3
-60Hz
or
460V-3
47 x 36 x 66
30 x 36 x 56
1000 Lbs. (454 Kgs.)
775 Lbs. (332 Kgs.)
-60Hz
• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.
• Unit specifications will change by adding certain options.
* Also available in 50Hz
Available Options
c l i c k
Similar Models (Click)
Custom Design
c l i c k
Non - Refrigerated Models
c l i c k
R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000
click for home page
Model R1000
100 Kelly Street, Elk Grove Village, IL 60007
Refrigerated Water Recirculating Systems
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
with air cooled condenser
with water cooled condenser
Watts
30,000
Btu/Hr 102,300
Watts 33,000
Btu/Hr 112,530
Compressor HP
10
10
Refrigerant
R22
R22
17 GPM (64.6 LPM)
17 GPM (64.6 LPM)
2
2
30 Gallons (114 Liters)
30 Gallons (114 Liters)
Cooling Capacity
( at 65°F supply water temp. )
Water Pump Capacity
several alternatives
available
Pump Motor HP
Reservoir Volume
Power Requirements*
Dimensions
several alternatives
available
( W x D x H ) in.
Shipping Weight
460V-3
-60Hz
460V-3
-60Hz
47 x 36 x 66
30 x 36 x 56
1200Lbs. (544 Kgs.)
900 Lbs. (408 Kgs.)
• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.
• Unit specifications will change by adding certain options.
* Also available in 50Hz
Available Options
c l i c k
Similar Models (Click)
Custom Design
c l i c k
Non - Refrigerated Models
c l i c k
R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000
click for home page
Non-Refrigerated Water Recirculating Systems
( Water-to-Water )
100 Kelly Street, Elk Grove Village, IL 60007, Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
Model
Cooling Capacity
Details
WW1
UpUp
ToTo
6,000 Watts (20,460 Btu/Hr)
Click Button For Tech Specs
WW2
UpToTo
Up
25,000 Watts (85,250 Btu/Hr)
Click Button For Tech Specs
WW3
Up
Up To
To
50,000 Watts (170,500 Btu/Hr)
Click Button For Tech Specs
WW4
Up To
150,000 Watts (511,500 Btu/Hr)
Click Button For Tech Specs
Available Options
c l i c k
Custom Design
c l i c k
Refrigerated Models
c l i c k
click for home page
Non-Refrigerated Water Recirculating Systems
Model WW1
100 Kelly Street, Elk Grove Village, IL 60007
12
Cooling Capacity
Determined by temperature and flow of
building water. See performance curve to
the right.
several alternatives
available
Pump Motor HP
1.7 GPM (6.4 LPM)
1/3
Reservoir Volume
Power Requirements*
5 Gallons (19 Liters)
several alternatives
available
( W x D x H ) in.
Shipping Weight
115-V-1
-60Hz
208/230V-1
dT= 10°F
10
Capacity (kW)
Water Pump Capacity
Dimensions
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
dT= 15°F
dT= 20°F
8
dT= 25°F
6
4
-60Hz
2
19 x 26 x 25
175 Lbs. (79 Kgs.)
0
1
• Unit specifications will change by adding certain options.
2
3
4
Building Water Flow (GPM)
* Also available in 50Hz
dT= Temperature differential between the building water and the supply water to your equipment.
BUILDING WATER = any source of cold water, including tap water or in-house chilled water.
Custom Design
Available Options
c l i c k
Similar Models (Click)
Refrigerated Models
c l i c k
c l i c k
WW1
WW2
WW3
WW4
click for home page
Non-Refrigerated Water Recirculating Systems
Model WW2
100 Kelly Street, Elk Grove Village, IL 60007
80
Cooling Capacity
Determined by temperature and flow of
building water. See performance curve to
the right.
several alternatives
available
Pump Motor HP
dT= 15°F
Power Requirements*
3.7 GPM (14.1 LPM)
14 Gallons (53 Liters)
several alternatives
available
( W x D x H ) in.
Shipping Weight
dT= 20°F
60
1/3
Reservoir Volume
dT= 10°F
70
Capacity (kW)
Water Pump Capacity
Dimensions
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
115-V-1
-60Hz
208/230V-1
-60Hz
dT= 25°F
50
40
30
20
30 x 25 x 34
10
250 Lbs. (113 Kgs.)
0
2
3
• Unit specifications will change by adding certain options.
4
5
6
7
8
Building Water Flow (GPM)
* Also available in 50Hz
dT= Temperature differential between the building water and the supply water to your equipment.
BUILDING WATER = any source of cold water, including tap water or in-house chilled water.
Custom Design
Available Options
c l i c k
Similar Models (Click)
Refrigerated Models
c l i c k
c l i c k
WW1
WW2
WW3
WW4
click for home page
Non-Refrigerated Water Recirculating Systems
Model WW3
100 Kelly Street, Elk Grove Village, IL 60007
Cooling Capacity
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
several alternatives
available
140
Pump Motor HP
3/4
Reservoir Volume
Power Requirements*
14 Gallons (53 Liters)
several alternatives
available
( W x D x H ) in.
Shipping Weight
dT= 10°F
dT= 15°F
120
7.9 GPM (30.0 LPM)
Capacity (kW)
Water Pump Capacity
Dimensions
160
Determined by temperature and flow of
building water. See performance curve to
the right.
115V
or 208/230V-1
208/230V-3
-60Hz
dT= 20°F
dT= 25°F
100
-60Hz
80
60
40
30 x 25 x 34
20
300 Lbs. (136 Kgs.)
0
4
5
6
7
8
9
10
11
12
13
14
15
Building Water Flow (GPM)
• Unit specifications will change by adding certain options.
dT= Temperature differential between the building water and the supply water to your equipment.
* Also available in 50Hz
BUILDING WATER = any source of cold water, including tap water or in-house chilled water.
Custom Design
Available Options
c l i c k
Similar Models (Click)
Refrigerated Models
c l i c k
c l i c k
WW1
WW2
WW3
WW4
click for home page
Non-Refrigerated Water Recirculating Systems
Model WW4
100 Kelly Street, Elk Grove Village, IL 60007
180
Cooling Capacity
Determined by temperature and flow of
building water. See performance curve to
the right.
several alternatives
available
Pump Motor HP
160
17 GPM (64.6 LPM)
1.5
Reservoir Volume
Power Requirements*
30 Gallons (113 Liters)
several alternatives
available
( W x D x H ) in.
Shipping Weight
dT= 10°F
dT= 15°F
140
Capacity (kW)
Water Pump Capacity
Dimensions
Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
208/230V-1
-60Hz
208/230V-3
-60Hz
dT= 20°F
120
dT= 25°F
100
80
60
40
31 x 36 x 34
20
400 Lbs. (181 Kgs.)
0
5
10
20
15
25
Building Water Flow (GPM)
• Unit specifications will change by adding certain options.
dT= Temperature differential between the building water and the supply water to your equipment.
* Also available in 50Hz
BUILDING WATER = any source of cold water, including tap water or in-house chilled water.
Custom Design
Available Options
c l i c k
Similar Models (Click)
Refrigerated Models
c l i c k
c l i c k
WW1
WW2
WW3
WW4
click for home page
Optional Design Features
Applies to all Haskris models
Basic Design Options:
To Refine or Enhance Performance:
Option (G): Manual refrigerant hot gas bypass system for improved
water temperature stability.
Option (C): Water-cooled condenser with water saver control valve.
For refrigerated units only.
For refrigerated units cooling a steady heat load. See option(H).
Option (D): Two separate water pumping systems.
Option (H): Electronically controlled refrigerant hot gas bypass
system for improved water temperature stability, to
+/- 0.1 C or better
.
Option (R): Alternate Water Pump
Option (Y): Multiple water circuits with flowmeters and metering
valves, when cooling more than one piece of equipment
from a single pump.
For refrigerated units cooling a variable heat load. Also
recommended for refrigerated units with air cooled condensers,
when ambient air temperatures are variable and water
temperature stability is critical.
Option (O): Hand shut-off valves. Recommended with Option (Y).
Option (I):
For refrigerated units with air cooled condensers, when
ambient air temperatures are excessively high.
Option (J):
For refrigerated units with air cooled condensers, when
ambient air temperatures are excessively low.
Option (H): Electronic close control for improved water
temperature stability.
For non-refrigerated, water-to-water (WW) units only.
Convenience Options:
Option (A): Flowmeter, to visually display flow of water through
equipment.
Option (M): Time clock, to operate the unit after normal working
hours, up to 60 minutes.
Option (P): Locking casters (in lieu of standard levelling legs).
To Protect Your Equipment:
Option (B): High temperature thermostat to de-energize pump
motor on a rise in water temperature.
Alternately, can be interlocked with your equipment.
Option (N): Alarm system for high water temperature. Choice of
“buzzer” only (single stage), or “buzzer” and pump
cutout in sequence (two stage).
Miscellaneous Options:
Option (K): Used to designate any “non-standard” feature you
would like built into your unit.
Option (S): Flow switch to provide protection if water flow fails for
any reason.
Option (L): Supply water filter.
Refrigerated Models
c l i c k
Click on the Custom Design button below
Non - Refrigerated Models
c l i c k
100 Kelly Street, Elk Grove Village, IL 60007, Ph: 847-956-6420 Fax: 847-956-6595, [email protected]
Custom Design
c l i c k
click for home page
100 Kelly Street, Elk Grove Village, IL 60007
Ph: 847-956-6420
Fax: 847-956-6595
[email protected]
Please call us to speak with one of our design engineers.
e
l
p
m
a
x
e
All Haskris systems are built to order.
We specialize in custom designs.
While we have a standard product
line and many standard options, we
rarely sell a standard system .
Rather, we learn the application and
customize the cooling system to the
specific needs of the application. We
strongly encourage our customers to
"think outside the box" when
developing the design spec. for the
chiller because we have complete
flexibility with our design. We can
do things other chiller manufacturers
are not set up to do.
s
Custom Design
• Special materials of construction
(stainless steel, PVC, food grade components, etc)
• Low temp designs
• High temp design
• Custom dimensions to fit into a confined space
• Piping manifolds for remote flow control
• Multiple pumping systems
• High pressure designs
• Remote control panels
• RS-232 communication
• Custom alarms, safeties & interlocks
• Flow rates from 0.1 GPM to 75.0 GPM
• Custom designs for uncommon electrical service
• Split refrigeration systems
• Alternate refrigerants
• Automatic reservoir refill
• Automatic city water switchover
• Water-to-air heat exchangers
• Etc...
We look forward to working with you to design a cooling system tailored to the
special needs of your equipment or installation site.