Airborne molds and allergens are problems
the more crowded a place is.
Plasmacluster technology
There are many hazardous substances around us that are invisible to the eye. Air quality has become an issue in places where people
Plasma discharge generates and emits the same positive
and negative ions that occur in nature. Plasmacluster
technology is Sharp’s original air disinfecting technology
that inactivates suspended airborne mold and viruses.
gather such as offices, stores, hotels, schools, hospitals and so forth. The airborne molds, viruses and allergens that permeate these
places are a major cause of discomfort to guests and people who work there. Because of these times, Sharp developed proprietary
Plasmacluster technology that powerfully inactivates harmful airborne substances that permeate indoor air environments.
Winner of the Invention Prize at the 2008
National Invention Awards Ceremony
held by the Japan Institute of Invention
and Innovation (JIII)
What Sharp hopes for is to contribute in whatever way it can to making business environments healthier and more comfortable.
Patented by Sharp (patent No. 3680121)
Inactivates airborne molds, allergens and even viruses.
Welcome the Plasmacluster Ion Generator for a healthier and more comfortable workplace.
Sharp’s Plasmacluster is the only technology that uses positive and negative ions to disinfect the air.
High density and long-lasting ions make a powerful
attack on dirty air across the entire room.
How Plasmacluster ions are generated
Positive and negative voltages are applied to discharge electrodes in
order to electrically breakdown water and oxygen molecules in the
air. This produces positive hydrogen ions and negative oxygen ions.
Plasmacluster ions are the same positive and negative ions found in
nature. The ions are long lasting as surrounded by water molecules,
and are released into the air.
Positive hydrogen ion
H+
Mold Spores
Negative oxygen ion
O 2-
H+
O 2-
Airborne water
Airborne oxygen
H 2O
Hydroxide (OH) radical
H 2O
O2
O2
Viruses
Hydrogen (H)
Discharge
electrode (+)
Plasma area
Discharge
electrode (-)
Plasma area
Protein
The airborne water molecules cluster around the ions like a bunch
of grapes, transforming each ion into a stable cluster ion.
Dust Mite Feces
The ions form hydroxide radicals that are highly oxidizing only when
they adhere to the surfaces of mold and viruses. They instantly remove
the hydrogen from the surface proteins, breaking them down.
The formed ions are unstable on their own.
Positive
ion
Negative
ion
H+
H 2O
H 2O
H 2O
H+
H 2O
O 2-
H 2O
H 2O
H 2O
O 2-
H2O
H 2O
H 2O
“High density Plasmacluster ion
generating unit”
Water molecules cluster around the
ion to stabilize it.
The hydroxide (OH) radicals combine with hydrogen (H) to form
water (H2O) which returns to the air.
When Plasmacluster ions stick to the surface of the airborne
substances, they instantly form OH radicals of strong standard
oxidation potential that robs hydrogen from the protein of the
airborne substances.
Inactivation
of
mold
Sharp continues research into air purification
because of growing social awareness, with the
primar y wish of bringing cleaner air to the world.
Sharp’s original Plasmacluster technology inactivates harmful
airborne substances, and that performance has been steadily
improved since its development in 2000. From the home to the
office. From Japan to the world. We pursue even higher
performance as the means for bringing cleaner air to more
places. We want to spread this new culture of air purification
around the world.
Inactivation
of
Inactivation
of
viruses
allergens
Inactivation
of
adhering
odour
Plasmacluster ions generate OH radicals.
Oxidized substance
(Substance robbed of H+)
Chemical
formula
Standard oxidation potential
(Power to steal H+)
Oxygen radical
• OH
2.81
Oxygen atom
O
2.42
Ozone
O3
2.07
Hydrogen peroxide
H2 O 2
1.78
Oxygen molecule
O2
1.23
Source: Ozone Fundamentals and Applications
• To enable stable emission of high-density Plasmacluster ions, the Plasmacluster ion generating unit module will need to be replaced periodically*.
* Replacement is required approximately every 17,500 hours, roughly 2 years when operated continuously for 24 hours a day. Unit will stop operating after about 19,000 hours
(2 years and 2 months) if the Plasmacluster ion generating unit is not replaced.
1
• The final product appearance may differ from the product photos and unit photos in this catalogue.
2
Airborne molds and allergens are problems
the more crowded a place is.
Plasmacluster technology
There are many hazardous substances around us that are invisible to the eye. Air quality has become an issue in places where people
Plasma discharge generates and emits the same positive
and negative ions that occur in nature. Plasmacluster
technology is Sharp’s original air disinfecting technology
that inactivates suspended airborne mold and viruses.
gather such as offices, stores, hotels, schools, hospitals and so forth. The airborne molds, viruses and allergens that permeate these
places are a major cause of discomfort to guests and people who work there. Because of these times, Sharp developed proprietary
Plasmacluster technology that powerfully inactivates harmful airborne substances that permeate indoor air environments.
Winner of the Invention Prize at the 2008
National Invention Awards Ceremony
held by the Japan Institute of Invention
and Innovation (JIII)
What Sharp hopes for is to contribute in whatever way it can to making business environments healthier and more comfortable.
Patented by Sharp (patent No. 3680121)
Inactivates airborne molds, allergens and even viruses.
Welcome the Plasmacluster Ion Generator for a healthier and more comfortable workplace.
Sharp’s Plasmacluster is the only technology that uses positive and negative ions to disinfect the air.
High density and long-lasting ions make a powerful
attack on dirty air across the entire room.
How Plasmacluster ions are generated
Positive and negative voltages are applied to discharge electrodes in
order to electrically breakdown water and oxygen molecules in the
air. This produces positive hydrogen ions and negative oxygen ions.
Plasmacluster ions are the same positive and negative ions found in
nature. The ions are long lasting as surrounded by water molecules,
and are released into the air.
Positive hydrogen ion
H+
Mold Spores
Negative oxygen ion
O 2-
H+
O 2-
Airborne water
Airborne oxygen
H 2O
Hydroxide (OH) radical
H 2O
O2
O2
Viruses
Hydrogen (H)
Discharge
electrode (+)
Plasma area
Discharge
electrode (-)
Plasma area
Protein
The airborne water molecules cluster around the ions like a bunch
of grapes, transforming each ion into a stable cluster ion.
Dust Mite Feces
The ions form hydroxide radicals that are highly oxidizing only when
they adhere to the surfaces of mold and viruses. They instantly remove
the hydrogen from the surface proteins, breaking them down.
The formed ions are unstable on their own.
Positive
ion
Negative
ion
H+
H 2O
H 2O
H 2O
H+
H 2O
O 2-
H 2O
H 2O
H 2O
O 2-
H2O
H 2O
H 2O
“High density Plasmacluster ion
generating unit”
Water molecules cluster around the
ion to stabilize it.
The hydroxide (OH) radicals combine with hydrogen (H) to form
water (H2O) which returns to the air.
When Plasmacluster ions stick to the surface of the airborne
substances, they instantly form OH radicals of strong standard
oxidation potential that robs hydrogen from the protein of the
airborne substances.
Inactivation
of
mold
Sharp continues research into air purification
because of growing social awareness, with the
primar y wish of bringing cleaner air to the world.
Sharp’s original Plasmacluster technology inactivates harmful
airborne substances, and that performance has been steadily
improved since its development in 2000. From the home to the
office. From Japan to the world. We pursue even higher
performance as the means for bringing cleaner air to more
places. We want to spread this new culture of air purification
around the world.
Inactivation
of
Inactivation
of
viruses
allergens
Inactivation
of
adhering
odour
Plasmacluster ions generate OH radicals.
Oxidized substance
(Substance robbed of H+)
Chemical
formula
Standard oxidation potential
(Power to steal H+)
Oxygen radical
• OH
2.81
Oxygen atom
O
2.42
Ozone
O3
2.07
Hydrogen peroxide
H2 O 2
1.78
Oxygen molecule
O2
1.23
Source: Ozone Fundamentals and Applications
• To enable stable emission of high-density Plasmacluster ions, the Plasmacluster ion generating unit module will need to be replaced periodically*.
* Replacement is required approximately every 17,500 hours, roughly 2 years when operated continuously for 24 hours a day. Unit will stop operating after about 19,000 hours
(2 years and 2 months) if the Plasmacluster ion generating unit is not replaced.
1
• The final product appearance may differ from the product photos and unit photos in this catalogue.
2
Progressing further, high-density Plasmacluster technology.
Higher ion density for an increased effect.
“Plasmacluster” is an original technology of Sharp for purifying air by discharging highly stable + and – ions similar to those that
exist in the natural world. It inactivates a number of airborne substances such as molds, viruses and allergens. Its effect has been
verified by public testing institutions around the world.
Proven Effectiveness of
Plasmacluster Ions
Effectiveness rises with increasing density.
Inactivation of viruses
Increasing viruses inactivation performance
by increasing ion density
Reduction of airborne viruses
High-density Plasmacluster ions are highly effective at inactivating suspended viruses.
They inactivate 99.9% of suspended viruses.
(Experimental result for 1 m3 box)
Without Plasmacluster ions
Reduction of airborne viruses
Percent remaining : 100%
(Experimental result for 1 m3 box)
With
Plasmacluster ions
99% inhibited in about 10 minutes.
(7,000 ions/cm3)
10%
50%
Natural attenuation
60
With Plasmacluster ions
(3,000 ions/cm3)
40
20
0
30
60
90
120
150
180 195 (Min.)
• Tested by: Ishikawa Health Service Association
• Test method: Plasmacluster ions were emitted into an experimental chamber
with a floor area of about 13 m2, and the suspended mold was measured with
an air sampler. Sharp has graphed the results using approximate figures.
(Plasmacluster ion density: 3,000 ions/cm3)
Inactivation of adhering odour
0.1%
1%
Identification of ion types
100%
The types of Plasmacluster ions have been identified
and verified to be the same as naturally existing ions.
• Tested by: Japan Food Research Laboratories
• Test results: No. 208070713-001 of July 23, 2008
• Test method: Sharp generated ions in a space of 2.6 m3,
grew mold on PVC plates for 5 days, and entrusted them to
test institution. Mold growth areas were compared as directed
by JIS Z2911. Sharp plotted the results. (Plasmacluster ion density:
50,000 ions/cm3)
Mold exposed to
Plasmacluster ions
3
(50,000 ions/cm )
* The ion density generated when operated at the
HIGH airstream setting, measured a horizontal distance
of 2 meters (in the direction of ion emission), at a height
of 1.2 meters from the floor.
50 to 100% of total
4
The same type of ions as those in nature
3
Plasmacluster ions are positive and negative ions that adhere
to the surfaces of suspended airborne microbes and form highly
oxidizing hydroxide radicals that physically break down and remove
the proteins on the surfaces of suspended microbes. Since they are
the same as naturally occurring ions while airborne, they can exist in
higher densities in homes.
0 to 25% of total
2
1
0
Mold exposed to Plasmacluster ions
Mold allowed
to grow naturally
(50,000 ions/cm3)*
Mold allowed
to grow naturally
GLP*-compliant test facilities have gathered highly reliable safety data on
Sharp’s Plasmacluster technology.
• Skin irritation/corrosion test
• Eye irritation/corrosion test
• Inhalation toxicity test
(lung tissue genetic impact assessment)
Tested by: Mitsubishi
Chemical Safety Institute
* GLP (Good Laboratory Practice) is a system of management controls for test facilities
and test procedures designed to ensure the reliability of chemical safety assessment tests.
Increase in adhering odour removal speed: Approx. doubled*
High-density Plasmacluster ions increase deodorizing speed. They reduced cigarette
smoke odour in a room to an unnoticeable level in about 60 minutes.
Removing cigarette smoke odour
Reducing cigarette smoke odour from cloth
Deodorizes to
unnoticeable level
in about 2 hours.
2.0
2
5
• Tested by: Japan Spinners Inspecting Foundation
• Test method: The deodorizing effectiveness on a
cloth swatch impregnated with cigarette smoke
odour components was evaluated by the six-level
odour intensity indication method. Sharp has
converted and calculated the results.
4
Odour intensity
3.1
1
Ratio of suspended
viruses remaining:
Inactivated by 99.9% in
about 10 minutes.
Reduction of growth of adhering mold
Elimination
Percent remaining (%)
80
0
The ions react only with the protein on the surface of
airborne substances without affecting internal cells, etc.
High-density Plasmacluster ions inactivate suspended mold and reduce the growth of
adhered mold.
100
(5,000 ions/cm3)
1%
Reducing growth of adhering mold
Reduction of airborne mold
With
Plasmacluster ions
Highly reliable safety data has already been obtained by
GLP* (Good Laboratory Practice) compliant test institutes.
With Plasmacluster ions (50,000 ions/cm3)*
0.1%
Natural decrease
Identification of active mechanism
Ratio of suspended
viruses remaining:
99% inactivated in
about 10 minutes.
* The ion density generated when operated at the
HIGH airstream setting, measured a horizontal distance
of 2 meters (in the direction of ion emission), at a height
of 1.2 meters from the floor.
Inactivation of mold
Obtaining of safety data
With Plasmacluster ions (7,000 ions/cm3)
100%
• Tested by: Retroscreen Virology Ltd., UK
• Test method: Viruses were suspended in the air in a 1 m3 box,
and the percentage of airborne viruses inactivated was measured.
(Plasmacluster ion density: 7,000 ions/cm3)
Safety verification
of Plasmacluster
Percent remaining: 100%
• Tested by: Retroscreen Virology Ltd., UK
• Test method: Viruses were suspended in the air in
a 1 m3 box, and the percentage of airborne viruses
inactivated was measured.
Area of mold filaments grown
Without
Plasmacluster ions
Plasmacluster ions are the same as ions found in nature, and their safety has been verified.
3 Odour intensity
Inactivation effectiveness for dust
mite allergens in suspended
house dust
Plasmacluster ions cut through and remove
proteins in suspended allergens generated
by dust mite feces and dead mites, reducing
their effects.
Dust mite feces
Dead dust mite
Natural decrease
Sales of Products Equipped with Sharp’s Plasmacluster Ion Technology Has Reached 20
Million* Units Worldwide.
2
0
Plasmacluster ions
(ion density:
20,000 ions/cm3)
Deodorizing speed:
Approx. doubled*
60 minutes
2 hours later
2
Density change in airborne
dust mite allergens (pg/cm3)
Inactivation of allergens
from dead dust mites
and dust mite feces
* Comparison of 5,000 ions/cm3 and 20,000 ions/cm3 Plasmacluster ion densities
Reduces odour to
unnoticeable level in
about 60 minutes.
3
1
• Tested by: Japan Spinners Inspecting Foundation
• Test method: The deodorizing effectiveness on a cloth swatch
impregnated with cigarette smoke odour components was evaluated by
the six-level odour intensity indication method. Sharp has converted and
calculated the results. (Plasmacluster ion density: 5,000 ions/cm3)
Plasmacluster ions (ion density 5,000 ions/cm3)
Increase
Without Plasmacluster ions
Stops
allergens
increasing.
With Plasmacluster
ions (3,000 ions/cm3)
Initial
value
1
• Tested by: Hiroshima University Graduate School of Advanced Sciences of Matter
• Test method: The effect of dust mite allergens in an uncleaned room (with a floor
area of about 13 m2) was measured in an actual home by the ELISA (Enzyme-Linked
ImmunoSorbant Assay) method. Sharp converted the results and calculated the
average value. (Plasmacluster ion density: 3,000 ions/cm3)
* Total number of Sharp Plasmacluster
products and Plasmacluster ion
generating devices shipped within
Japan and overseas between
October 2000 and December 2008.
• While it can inactivate suspended viruses and other contaminants, it cannot create a completely sterile environment. Sharp does not guarantee its ability to prevent microbial infection.
• Actual numbers of ions and disinfecting/purifying effectiveness will vary according to the room conditions and operating method.
3
4
Progressing further, high-density Plasmacluster technology.
Higher ion density for an increased effect.
“Plasmacluster” is an original technology of Sharp for purifying air by discharging highly stable + and – ions similar to those that
exist in the natural world. It inactivates a number of airborne substances such as molds, viruses and allergens. Its effect has been
verified by public testing institutions around the world.
Proven Effectiveness of
Plasmacluster Ions
Effectiveness rises with increasing density.
Inactivation of viruses
Increasing viruses inactivation performance
by increasing ion density
Reduction of airborne viruses
High-density Plasmacluster ions are highly effective at inactivating suspended viruses.
They inactivate 99.9% of suspended viruses.
(Experimental result for 1 m3 box)
Without Plasmacluster ions
Reduction of airborne viruses
Percent remaining : 100%
(Experimental result for 1 m3 box)
With
Plasmacluster ions
99% inhibited in about 10 minutes.
(7,000 ions/cm3)
10%
50%
Natural attenuation
60
With Plasmacluster ions
(3,000 ions/cm3)
40
20
0
30
60
90
120
150
180 195 (Min.)
• Tested by: Ishikawa Health Service Association
• Test method: Plasmacluster ions were emitted into an experimental chamber
with a floor area of about 13 m2, and the suspended mold was measured with
an air sampler. Sharp has graphed the results using approximate figures.
(Plasmacluster ion density: 3,000 ions/cm3)
Inactivation of adhering odour
0.1%
1%
Identification of ion types
100%
The types of Plasmacluster ions have been identified
and verified to be the same as naturally existing ions.
• Tested by: Japan Food Research Laboratories
• Test results: No. 208070713-001 of July 23, 2008
• Test method: Sharp generated ions in a space of 2.6 m3,
grew mold on PVC plates for 5 days, and entrusted them to
test institution. Mold growth areas were compared as directed
by JIS Z2911. Sharp plotted the results. (Plasmacluster ion density:
50,000 ions/cm3)
Mold exposed to
Plasmacluster ions
3
(50,000 ions/cm )
* The ion density generated when operated at the
HIGH airstream setting, measured a horizontal distance
of 2 meters (in the direction of ion emission), at a height
of 1.2 meters from the floor.
50 to 100% of total
4
The same type of ions as those in nature
3
Plasmacluster ions are positive and negative ions that adhere
to the surfaces of suspended airborne microbes and form highly
oxidizing hydroxide radicals that physically break down and remove
the proteins on the surfaces of suspended microbes. Since they are
the same as naturally occurring ions while airborne, they can exist in
higher densities in homes.
0 to 25% of total
2
1
0
Mold exposed to Plasmacluster ions
Mold allowed
to grow naturally
(50,000 ions/cm3)*
Mold allowed
to grow naturally
GLP*-compliant test facilities have gathered highly reliable safety data on
Sharp’s Plasmacluster technology.
• Skin irritation/corrosion test
• Eye irritation/corrosion test
• Inhalation toxicity test
(lung tissue genetic impact assessment)
Tested by: Mitsubishi
Chemical Safety Institute
* GLP (Good Laboratory Practice) is a system of management controls for test facilities
and test procedures designed to ensure the reliability of chemical safety assessment tests.
Increase in adhering odour removal speed: Approx. doubled*
High-density Plasmacluster ions increase deodorizing speed. They reduced cigarette
smoke odour in a room to an unnoticeable level in about 60 minutes.
Removing cigarette smoke odour
Reducing cigarette smoke odour from cloth
Deodorizes to
unnoticeable level
in about 2 hours.
2.0
2
5
• Tested by: Japan Spinners Inspecting Foundation
• Test method: The deodorizing effectiveness on a
cloth swatch impregnated with cigarette smoke
odour components was evaluated by the six-level
odour intensity indication method. Sharp has
converted and calculated the results.
4
Odour intensity
3.1
1
Ratio of suspended
viruses remaining:
Inactivated by 99.9% in
about 10 minutes.
Reduction of growth of adhering mold
Elimination
Percent remaining (%)
80
0
The ions react only with the protein on the surface of
airborne substances without affecting internal cells, etc.
High-density Plasmacluster ions inactivate suspended mold and reduce the growth of
adhered mold.
100
(5,000 ions/cm3)
1%
Reducing growth of adhering mold
Reduction of airborne mold
With
Plasmacluster ions
Highly reliable safety data has already been obtained by
GLP* (Good Laboratory Practice) compliant test institutes.
With Plasmacluster ions (50,000 ions/cm3)*
0.1%
Natural decrease
Identification of active mechanism
Ratio of suspended
viruses remaining:
99% inactivated in
about 10 minutes.
* The ion density generated when operated at the
HIGH airstream setting, measured a horizontal distance
of 2 meters (in the direction of ion emission), at a height
of 1.2 meters from the floor.
Inactivation of mold
Obtaining of safety data
With Plasmacluster ions (7,000 ions/cm3)
100%
• Tested by: Retroscreen Virology Ltd., UK
• Test method: Viruses were suspended in the air in a 1 m3 box,
and the percentage of airborne viruses inactivated was measured.
(Plasmacluster ion density: 7,000 ions/cm3)
Safety verification
of Plasmacluster
Percent remaining: 100%
• Tested by: Retroscreen Virology Ltd., UK
• Test method: Viruses were suspended in the air in
a 1 m3 box, and the percentage of airborne viruses
inactivated was measured.
Area of mold filaments grown
Without
Plasmacluster ions
Plasmacluster ions are the same as ions found in nature, and their safety has been verified.
3 Odour intensity
Inactivation effectiveness for dust
mite allergens in suspended
house dust
Plasmacluster ions cut through and remove
proteins in suspended allergens generated
by dust mite feces and dead mites, reducing
their effects.
Dust mite feces
Dead dust mite
Natural decrease
Sales of Products Equipped with Sharp’s Plasmacluster Ion Technology Has Reached 20
Million* Units Worldwide.
2
0
Plasmacluster ions
(ion density:
20,000 ions/cm3)
Deodorizing speed:
Approx. doubled*
60 minutes
2 hours later
2
Density change in airborne
dust mite allergens (pg/cm3)
Inactivation of allergens
from dead dust mites
and dust mite feces
* Comparison of 5,000 ions/cm3 and 20,000 ions/cm3 Plasmacluster ion densities
Reduces odour to
unnoticeable level in
about 60 minutes.
3
1
• Tested by: Japan Spinners Inspecting Foundation
• Test method: The deodorizing effectiveness on a cloth swatch
impregnated with cigarette smoke odour components was evaluated by
the six-level odour intensity indication method. Sharp has converted and
calculated the results. (Plasmacluster ion density: 5,000 ions/cm3)
Plasmacluster ions (ion density 5,000 ions/cm3)
Increase
Without Plasmacluster ions
Stops
allergens
increasing.
With Plasmacluster
ions (3,000 ions/cm3)
Initial
value
1
• Tested by: Hiroshima University Graduate School of Advanced Sciences of Matter
• Test method: The effect of dust mite allergens in an uncleaned room (with a floor
area of about 13 m2) was measured in an actual home by the ELISA (Enzyme-Linked
ImmunoSorbant Assay) method. Sharp converted the results and calculated the
average value. (Plasmacluster ion density: 3,000 ions/cm3)
* Total number of Sharp Plasmacluster
products and Plasmacluster ion
generating devices shipped within
Japan and overseas between
October 2000 and December 2008.
• While it can inactivate suspended viruses and other contaminants, it cannot create a completely sterile environment. Sharp does not guarantee its ability to prevent microbial infection.
• Actual numbers of ions and disinfecting/purifying effectiveness will vary according to the room conditions and operating method.
3
4
Discharges a high density Plasmacluster ions across a wide area to quickly
and powerfully inactivate airborne substances and purify air in crowded places.
The delivery mechanism is Sharp's original technology for applying flow control.
Technology for delivering high density Plasmacluster around people
A high density of Plasmacluster ions inactivate airborne
substances and purify air across a wide area where people
are active.
Ions follow the layer of air
across the room.
The layer of air presses
on the ions.
The airflow blown from the highest louver creates a layer
of air that presses on the ions to ensure a high density
reaches far across the room.
It simultaneously generates a large quantity of Plasmacluster ions and delivers them far across the entire room.
Delivered in high density, the Plasmacluster ions powerfully inactivate airborne molds and viruses.
Efficiently releases a high density ions across wide areas.
Wide louver for high output.
The wide louver the product employs efficiently releases a
high density of Plasmacluster ions across wide areas such
as lobbies and waiting rooms.
The airflow near the Plasmacluster ion generating
unit increases to produce more ions.
Delivery range of high density Plasmacluster ions
Applicable floor surface
area: Approx. 50 m2
Approx. 6 m
Applicable floor surface area:
Approx. 50 m2
Airflow is
evenly divided by the Coanda
effect of the internal walls of the
air channel.
480 mm
*What is the Coanda effect?
It is a characteristic of air and liquid jets that, when blown
along surfaces, tend to follow the surface even if exhausted
or curved downstream.
Approx. 8 m
Applicable floor surface
area: Approx. 23 m2
Approx. 3 m
Approx. 7.5 m
•Actual numbers of ions and disinfecting/purifying effectiveness will vary according to the room conditions and operating method.
Applicable floor surface area: Approx. 23 m2
940 mm
Higher ion densities with a Plasmacluster ion
generating unit.
The Plasmacluster ion generating device has been built
and incorporated as a detachable modular unit, which
both increases the density of the ion flow and ensures a
stable consistent flow of ions at all times. A lamp on the
front panel of the product notifies the user when it is time
to replace the unit.
480 mm
Wall
surface
Profile
60 mm
or more
230 mm
Plasmacluster ion generating unit for replacement
(Plasmacluster ion generating unit will need to be replaced periodically.)
*After about 17,500 total hours of operations (about 2 years when run continuously 24 hours
a day), a lamp on the front panel starts flashing to notify the user that it is time to replace
the unit.
Filter cleaning lamp
Unit replacement lamp
Air volume lamp
594 mm
Plasmacluster ion generating unit replacement
•The Plasmacluster ion generating unit will need to be replaced periodically to enable continuous stable emission of high-density
Plasmacluster ions.
•The product stops running after about 19,000 hours (approx. 2 years and 2 months) if the unit is not replaced.
•The Plasmacluster ion generating unit may need to be replaced sooner when used in some environments or locations (such as locations of
suspended cooking oil droplets or other oil components, dusty or humid locations, or locations where sprays or chemicals are used).
Designed for both low power consumption and quiet
operation for comfortable use year-round
The product is designed to consume about 10 W*.
Furthermore, the operating noise is the same 34 db*
demanded for libraries, so the product can be used
comfortably all year-round.
5
• The final product appearance may differ from the product photos and unit photos in this catalogue.
Breaker interlock to prevent unnecessary running
If the breaker interlock switch is
set in the ON position and then the
product is accidentally unplugged
or the breaker trips during use, the
last used operating mode resumes
automatically when power is restored.
6
Discharges a high density Plasmacluster ions across a wide area to quickly
and powerfully inactivate airborne substances and purify air in crowded places.
The delivery mechanism is Sharp's original technology for applying flow control.
Technology for delivering high density Plasmacluster around people
A high density of Plasmacluster ions inactivate airborne
substances and purify air across a wide area where people
are active.
Ions follow the layer of air
across the room.
The layer of air presses
on the ions.
The airflow blown from the highest louver creates a layer
of air that presses on the ions to ensure a high density
reaches far across the room.
It simultaneously generates a large quantity of Plasmacluster ions and delivers them far across the entire room.
Delivered in high density, the Plasmacluster ions powerfully inactivate airborne molds and viruses.
Efficiently releases a high density ions across wide areas.
Wide louver for high output.
The wide louver the product employs efficiently releases a
high density of Plasmacluster ions across wide areas such
as lobbies and waiting rooms.
The airflow near the Plasmacluster ion generating
unit increases to produce more ions.
Delivery range of high density Plasmacluster ions
Applicable floor surface
area: Approx. 50 m2
Approx. 6 m
Applicable floor surface area:
Approx. 50 m2
Airflow is
evenly divided by the Coanda
effect of the internal walls of the
air channel.
480 mm
*What is the Coanda effect?
It is a characteristic of air and liquid jets that, when blown
along surfaces, tend to follow the surface even if exhausted
or curved downstream.
Approx. 8 m
Applicable floor surface
area: Approx. 23 m2
Approx. 3 m
Approx. 7.5 m
•Actual numbers of ions and disinfecting/purifying effectiveness will vary according to the room conditions and operating method.
Applicable floor surface area: Approx. 23 m2
940 mm
Higher ion densities with a Plasmacluster ion
generating unit.
The Plasmacluster ion generating device has been built
and incorporated as a detachable modular unit, which
both increases the density of the ion flow and ensures a
stable consistent flow of ions at all times. A lamp on the
front panel of the product notifies the user when it is time
to replace the unit.
480 mm
Wall
surface
Profile
60 mm
or more
230 mm
Plasmacluster ion generating unit for replacement
(Plasmacluster ion generating unit will need to be replaced periodically.)
*After about 17,500 total hours of operations (about 2 years when run continuously 24 hours
a day), a lamp on the front panel starts flashing to notify the user that it is time to replace
the unit.
Filter cleaning lamp
Unit replacement lamp
Air volume lamp
594 mm
Plasmacluster ion generating unit replacement
•The Plasmacluster ion generating unit will need to be replaced periodically to enable continuous stable emission of high-density
Plasmacluster ions.
•The product stops running after about 19,000 hours (approx. 2 years and 2 months) if the unit is not replaced.
•The Plasmacluster ion generating unit may need to be replaced sooner when used in some environments or locations (such as locations of
suspended cooking oil droplets or other oil components, dusty or humid locations, or locations where sprays or chemicals are used).
Designed for both low power consumption and quiet
operation for comfortable use year-round
The product is designed to consume about 10 W*.
Furthermore, the operating noise is the same 34 db*
demanded for libraries, so the product can be used
comfortably all year-round.
5
• The final product appearance may differ from the product photos and unit photos in this catalogue.
Breaker interlock to prevent unnecessary running
If the breaker interlock switch is
set in the ON position and then the
product is accidentally unplugged
or the breaker trips during use, the
last used operating mode resumes
automatically when power is restored.
6
Plasmacluster Ion Generator
Sales of Products Equipped with
Sharp’s Plasmacluster Ion Technology Has Reached
*
Worldwide
Powerfully Inactivate Airborne Substances
High Density Plasmacluster Technology Incorporated
Design and specifications subject to change without notice.