contracer - Measure-All
Transcription
contracer - Measure-All
Surface-, Form-, and Contour Measurement CONTRACER ® Bulletin No. 1667 Contour Measuring Instruments Mitutoyo’s Contracer CV Series Powerful Lineup That's digital! All models feature a Z-axis with integrated digital-scale detecting unit. Mitutoyo’s Contracer CV Series is a high-accuracy contour measuring instrument with a digital scale on the X- and Z-axis. Digitization of the Z-axis gives you the following: • No need to calibrate the Z-axis according to measurement magnification • No need to change the Z-axis detection zone according to measurement magnification • High-accuracy measurement for largedisplacement contours That’s Mitutoyo! A wide selection of models designed to make measuring easier, more comfortable and more accurate! 2 Outstanding measurement support, thanks to Windows® OS-compatible “FORMPAK®-1000” Contour Analysis. Windows® 95 / Windows® 98 / Windows® NT4.0 / Windows®2000 is used as the OS. Program commands can be accessed via icons and a powerful Help function, making it easy for anyone to use… even a novice! Selection Guide Contracer CV Series Mitutoyo offers a range of models for every requirement. There’s sure to be one that fits your needs! CV-H628 ■ X-axis/Z-axis measuring range: 8" (200mm)/1" (25mm) ■ Vertical travel: ■ Base size (W x D): 10" (250mm) 24" x 18" (600 x 450mm) CV-3000W8 / CV-4000W8 ■ X-axis/Z-axis measuring range: 8" (200mm)/2" (50mm) ■ Vertical travel: ■ Base size (W x D): 18" (450mm) 40" x 18" (1000 x 450mm) CV-3000H8 / CV-4000H8 ■ X-axis/Z-axis measuring range: 8" (200mm)/2" (50mm) ■ Vertical travel: ■ Base size (W x D): 18" (450mm) 24" x 18" (610 x 450mm) CV-3000S8 / CV-4000S8 ■ X-axis/Z-axis measuring range: 8" (200mm)/2" (50mm) ■ Vertical travel: ■ Base size (W x D): 10" (250mm) 24" x 18" (610 x 450mm) CV-3000W4 / CV-4000W4 ■ X-axis/Z-axis measuring range: 4" (100mm)/2" (50mm) ■ Vertical travel: ■ Base size (W x D): 18" (450mm) 40" x 18" (1000 x 450mm) CV-3000H4 / CV-4000H4 CV-2000M4 ■ X-axis/Z-axis measuring range: 4" (100mm)/2" (50mm) ■ X-axis/Z-axis measuring range: 4" (100mm)/1.5" (40mm) ■ Vertical travel: ■ Vertical travel: ■ Base size (W x D): 18" (450mm) 24" x 18" (610 x 450mm) CV-3000S4 / CV-4000S4 ■ Base size (W x D): 10" (250mm) 24" x 18" (610 x 450mm) CV-1000N2 ■ X-axis/Z-axis measuring range: 4" (100mm)/2" (50mm) ■ X-axis/Z-axis measuring range: 2" (50mm)/1" (25mm) ■ Vertical travel: ■ Vertical travel: ■ Base size (W x D): 10" (250mm) 24" x 18" (610 x 450mm) ■ Base size (W x D): — — 3 Contracer X-axis resolution: .00000025" (0.00000625mm) Z-axis resolution: .0000005" (0.0000125mm) World-class resolution and accuracy (Z-axis) Small-footprint design… smart, simple operation! The electronic unit is housed within the measuring unit’s vibration isolator, and the vertical side table is a standard configuration that houses the data analysis unit. CV-H628 with personal computer system 4 FEATURES Equipped with the X- and Z-axis Laser Holoscale Principle of Laser Holoscale Mitutoyo’s holographic scale, which is based on the interference phenomenon of diffracted light, is incorporated into the detector as a measuring unit for the X- and Z-axes.The Laser Holoscale offers the world’s highest level of resolution along the X-axis .25µinch (0.00625µm), Z-axis .5µinch (0.0125µm) over the entire measurement range of the X-axis at 8" (200 mm), and the Z-axis 1" (25 mm). Laser Holoscale Standard accessories 997123 12AAA567 354903 12AAC169 211-016 546-113 537976 178-052-1 178-016 355130 Pin gage and holder Cone stylus Ball stylus Reversal mounting arm Reference hemisphere Dial tension gage Carrying bolts Digimatic XY leveling table with swivel Leveling table Machine cover FORMPAK®-1000 software is easy to operate, and capable of powerful analysis, concurrently. Gauge blocks 613192-221 (.2") 613194-221 (.4") 613201-221 (1") User’s manual (1set), Fuse,Wrenches, Screw driver, Power cord, GND wire Gage blocks are provided with Grade K of /ISO/JIS/DIN or Grade 1of Federal Standard 5 Contracer 6 CV-3000S4 with personal computer system X-axis resolution: .000002" (0.00005mm) Z-axis resolution: .000008" (0.0002mm) CV-4000S4 with personal computer system X-axis resolution: .000002" (0.00005mm) Z-axis resolution: .000002" (0.00005mm) FEATURES Featuring a digital scale unit installed in the Z-axis detection unit (CV-3000 Series) The CV-3000 Series, which uses a digital scale unit in its Z-axis detection unit, achieves a resolution of .000008" (0.0002 mm) at a full stroke of ±1" (±25 mm). And unlike conventional, differential transformer units, there is no change in resolution as the range of magnification changes.The result: a dramatic improvement in operation and performance! FORMPAK®-1000 software is easy to operate, and capable of powerful analysis, concurrently. Ceramic guides have been employed for abrasion resistance. A dedicated control box for ease of operation. • The control box, which is independent of the main unit, gives you remote control over positioning, measurement start/stop, returning, and other key operations. • The drive unit's up/down position and the X-axis traverse can be fine-tuned under manual control. Mitutoyo’s Holographic Scale delivers super-high accuracy (CV-4000 Series) • The new, top-of-the-line Holography Scale is based on the interference phenomenon of diffracted light, ensuring the absolute in accuracy. It allows dimensional measurement at a resolution of .000002" (0.00005mm) over the entire measurement range of 2" (50mm). Standard accessories 354884 996506 546-113 178-043-1 178-053-1 211-016 537976 352637 998861 538333 Gauge blocks High one-side cut stylus Straight arm Dial tension gage Leveling table (CV-4000 only, for metric) Leveling table (CV-4000 only, for inch/mm) Symmetry calibration gage (CV-4000 only) Carrying bolts Lubricant Pin gage (inch) and holder Thread gage (p=.05") (CV-3000) 611194-231 (.4") 611198-231 (.8") 611202-231 (2") Gauge blocks (CV-4000) Laser Holoscale 611194-221 (.4") 611198-221 (.8") 611202-221 (2") User’s manual (1set), Fuse,Wrenches, Screw driver, Connecting cables, Power cord, GND wire, Machine cover, Driving cable assembly, Column cable assembly Gage blocks are provided with Grade 0 of ISO/JIS/DIN or Grade 2 of Federal Standard for CV-3000 and Grade K of ISO/JIS/DIN or Grade 1 of Federal Standard for CV-4000 7 Contracer X-axis resolution: .000008" (0.0002mm) Z-axis resolution: .000016" (0.0004mm) Mitutoyo digitizes the X- and Z-axes over the full range, giving you a wider range of measurement with higher resolution. No more reliance on measurement magnifications! The CV-1000 is portable and can be carried to the machine-shop for measurement of large workpieces. Even at a site where a power source may not be nearby, the CV-1000 can work with the optional display unit (built-in rechargeable battery). X-axis resolution: .000008" (0.0002mm) Z-axis resolution: .00002" (0.0005mm) CV-2000M4 with personal computer system 8 FEATURES Display unit and XY plotter Optional stand Icons and graphics on the LCD and touch panel make it easy for anyone — even a novice — to perform key analysis operations.The contour profile can be confirmed with the display unit prior to output to an XY plotter. The Contracer CV-1000N2 can be attached to the optional stand. FORMPAK®-1000 software Connected to a personal computer, the FORMPAK-1000 contour analysis program provides various modes of measurement and analysis.When connected to an XY plotter, the contour profile can be checked with the display unit prior to output. System diagram Arc scale on Z-axis * The following plotters are recommended • MP5100-51 (Graphtec) • Y-1 x 50 (DXY-1150, 1250, 1350) (Roland) Standard accessories 357651 354884 935113 546-113 538333 Gauge blocks AC adapter High one-side cut stylus Straight arm Dial tension gage Thread gage (p=.5") (CV-1000) 611192-231 (.2") 611196-231 (.6") 611194-231 (.4") 611201-231 (1") Gauge blocks (CV-2000) 611194-231 (.4") 611198-231 (.8") 611201-231 (1") User’s manual (1set),Wrenches, Screw driver, Power cord, Connecting cables Gage blocks are provided with Grade 2 of ISO/JIS/DIN or Federal Standard 9 Software that’s easy to operate, and capable of powerful analysis, concurrently. FORMPAK-1000 is a powerful program that has an enhanced user interface, including mouse operation, a variety of graphic displays, and online help which is convenient if the user experiences a problem. In addition to being able to perform dimensional measurements such as angle, radius, and distance measurements, the contour tolerancing function for evaluating "form" and the report creation function for outputting measurement results in a specific format are provided as standard, ensuring both ease of operation and powerful analysis capabilities. Realtime measurement window Analysis result window Online help function Report creation function The appropriate help window displaying operating procedures, the definition of icons, etc., can be opened as required.This function eliminates the need to find information in the manual. Geometric measured data, measurement conditions, contour tolerancing results, and comments can be laid out as desired and printed out in a report. Once a layout has been saved, it can be reused as a glossary if the same measurement is made. A report can be printed in A3 size or from a color printer (option). Printout examples Layout edit window 10 User customization function External output function The size and position of operation buttons on a window can be modified as desired.This function allows the counter display, each window, the location of analysis command buttons, or the display color of measured data and auxiliary lines to be modified. Calculation results and tolerancing results can be downloaded in a readable format to commercial spreadsheet software.This function increases processing capabilities including statistical calculation, saving, and management of measurement results. It also allows measured point group data to be output in the text format. Contour tolerancing function This function compares measured data as “form” with nominal data, displays the deviation, and then stores it, being different from dimensional measurement of angle, radius, etc. In addition to values obtained from an ideal contour in a CAD drawing, nominal values can be created by converting the measured data of a master. Contour tolerancing flow Developed error display window Tolerancing result window Specifications Operation commands 1. Point measurement: Point, peak, contact, intersection, bisector-point (between elements/pieces of measured data) 2. Line measurement: Line, tangent line, perpendicular, parallel line, bisector 3. Circle measurement: Circle (multi-points, range, center and radius) 4. Position, difference: Coordinate difference, true position judgment 5. Distance, angle: Distance, groove length, step, pitch, distance reference, angle 6. Coordinate system setup: Origin setup, coordinate system rotation 7. Calculation, statistics: Arithmetic calculation, absolute value, square root, maximum value, minimum value, mean, sum, standard deviation, unbiased standard deviation, area 8. Editing of measured points: Deletion, translation, rotation, mirror image, positioning, combination, separation, projection Contour tolerancing 1. Nominal value data creation • Function specification (line/circle/aspheric surface, etc.), CAD input (IGES, DXF), measured data conversion, text file conversion • Tolerancing direction setup (normal direction/X-axis direction/Z-axis direction) 2. Reference coordinate system translation/rotation 3. Best-fit • X-axis translation, Z-axis translation, rotating direction, several kinds in combination 4. Nominal value tolerancing 5. Results display • Result list display, graphic display Special functions a. Sub-part program: Calculation procedure can be registered as a Sub-part program. The Sub-part program can be integrated into a part program facilitating measurement of batch of workpieces. b. Measured data/conditions saving: Measured data and analysis procedure can be saved in the hard disk. c. Layout Edit function: A measured profile, measurement conditions, etc., can be arranged in a form and laid out as desired. This function allows an original result report to be created and printed out. d. External output of files: Analysis results can be output in the CSV format, and therefore, can be easily accessed by commercial spreadsheet software. Also, measured data (point group data) can be output in the ASCII code. e. Part program: Measurement procedures complete with measurement, analysis, contour tolerance judgment, print, and save as a file, can be registered as a part program. The part program can be executed for automatic measurements. f. Polar coordinate development display: Develops a circular form on to the polar coordinate system, where the range for circle calculation can be specified. 11 Optional Accessories Rugged tables Rotary vises Cross-travel table Rotary vise • Table top: 11" x 7" (280 x 180mm) • Two-slide jaw type. • XY travel: 4" x 2" (100 x 50mm) • Max. workpiece size: ø2.4" (60mm) • Minimum reading: 1° Rotary table Rotary table • Table top: ø5.7" (146mm DIA) • Minimum reading: 2' • Holder with clamp (176-107) can be mounted. Holder with clamp Holder with clamp • Used with a cross-travel table or rugged table. • Max. workpiece height: 1.3" (35mm) 218-001 (mm) 218-011 (inch) 176-107 218-003 Cross-travel table • Table top: 11" x 6" (280 x 152mm) Rotary vise • One-slide jaw type. • XY travel: 2" x 1" (50 x 25mm) • Max. workpiece size: ø2.4" (60mm) • Minimum reading: 5° 172-196 Leveling tables XY leveling table with swivel • Table top: 5" x 4" (130 x 100mm) • Leveling range: ±1.5° • XY travel: ±.5" (±12.5mm) Center supports Swivel center support • Max. workpiece diameter: 3.1" (80mm)* *2.5" (65mm) when swiveled 10° • Max. workpiece length: 5.5" (140mm) 218-041 (mm) 218-051 (inch) Rugged table 172-144 • Table top: 11" x 7" (280 x 180mm) V-blocks • Provided with T-grooves for mounting workpiece fixtures. V-block with clamp • Used with a cross-travel table or rugged table. • Max. workpiece diameter: 2" (50mm) 218-002 172-197 178-043-1 (mm) 178-053-1 (inch) Center support • Max. workpiece diameter: 4.7" (120mm) • 2.3" (60mm) riser is optional (172-143). Digimatic XY leveling table with swivel • Table top: 5" x 4" (130 x 100mm) • Leveling range: ±1.5° • XY travel: ±.5" (±12.5mm) 172-142 Center support riser • Used with a center support. • Max. workpiece diameter: 9.4" (240mm) Vibrator isolator Vibration isolator • Dimensions (W x D x H): 30" x 22" x 2.3" (750 x 550 x 59mm) • Stand is optional (178-024). 172-234 V-block with clamp • Used with a cross-travel table or rugged table. • Max. workpiece diameter: 1" (25mm) 178-042-1 (mm) 178-052-1 (inch/mm) Leveling table • Table top: 5" x 4" (130 x 100mm) • Leveling range: ±1.5° • Height: 1.57" (40mm) 178-023 172-143 Vise Precision vise • Max. workpiece size: 1.42" (36mm) • Can be mounted on a leveling table. 172-378 178-016 12 178-019 Optional Accessories V-block V-block • Workpiece diameter: .04" to 6.3" (1mm to 160mm) • Can be mounted on a leveling table. Symmetry calibration gages Used to calibrate a slight circular error due to attachment errors of the stylus and arm. These gages are usually required to perform high-accuracy measurement of a lens, etc. Symmetry calibration gage (angle measurement type) Symmetry calibration gage (sphere measurement type) Others CV-H628 Windshield cover (12AAC168) CV-1000/2000 Display unit (218-341■) ■ Suffix: A for 120V, D for 220V, E for 240V or non for 100V CV-1000 Measuring stand (218-024) RAM card 997996 211-016 (12AAA841) 998291 Pin gage unit (CV-1000/2000) 998862 (mm) 998861 (inch) 13 Arms Optional Accessories For CV-3000/4000 Unit: inch (mm) Straight type 996504 996505 996506* 996507 996508 Eccentric type for .24" (6mm) high stylus for .47" (12mm) high stylus for .79" (20mm) high stylus for 1.18" (30mm) high stylus for 1.65" (42mm) high stylus 996509 996510 996511 996512 996513 For small hole stylus for .24" (6mm) high stylus for .47" (12mm) high stylus for .79" (20mm) high stylus for 1.18" (30mm) high stylus for 1.65" (42mm) high stylus 996514 *Standard accessory For CV-1000/2000 Unit: inch (mm) Straight type 935111 935112 935113* 935114 935115 Eccentric type for .24" (6mm) high stylus for .47" (12mm) high stylus for .79" (20mm) high stylus for 1.18" (30mm) high stylus for 1.65" (42mm) high stylus 935116 935117 935118 935119 935120 For small hole stylus 935110 for .24" (6mm) high stylus for .47" (12mm) high stylus for .79" (20mm) high stylus for 1.18" (30mm) high stylus for 1.65" (42mm) high stylus *Standard accessory ARM and STYLUS SET For CV-3000/4000 996660 Consists of three special arms and five special styli. 14 Order No. 996660 Components in set 996504 Straight arm for .24" (6mm) high stylus 996511 Eccentric arm for .79" (20mm) high stylus 996514 Arm for small hole stylus 354882 .24" (6mm) high one-sided cut stylus 354889 .79" (20mm) high intersecting cut stylus 354894 .79" (20mm) high cone stylus 996540 Small hole stylus 996542 Small hole stylus Styli Optional Accessories For CV-3000/4000, CV-1000/2000, (CV-H628) One-sided cut Intersecting cut Tip angle: 20° Tungsten carbide Tip angle: 12° Tungsten carbide H .24" (6mm) .47" (12mm) .79" (20mm) 1.18" (30mm) 1.65" (42mm) Order No. 354882 354883 (CV-H628) 354884* 354885 354886 H .24" (6mm) .47" (12mm) .79" (20mm) 1.18" (30mm) 1.65" (42mm) Order No. 354887 354888 (CV-H628) 354889 354890 354891 * CV-1000/2000/3000/4000 Standard accessory Tip angle: 20° Edge width: 3mm Tungsten carbide Order No. 354897 354898 (CV-H628) 354899 354900 354901 Tip angle: 30° Sapphire or Tungsten carbide H Order No. Sapphire tip .24" (6mm) 354887 .47" (12mm) 354888 (CV-H628) .79" (20mm) 354889 1.18" (30mm) 354890 1.65" (42mm) 354891 Ball Knife edge H .24" (6mm) .47" (12mm) .79" (20mm) 1.18" (30mm) 1.65" (42mm) For small hole stylus 12AAA568 12AAA569 12AAA570 Diamond Ball diameter: 1mm Tungsten carbide H .24" (6mm) .47" (12mm) .79" (20mm) 1.18" (30mm) 1.65" (42mm) Order No. Tungsten tip 12AAA566 12AAA567 Order No. 354902 354903 (CV-H628)* 354904 354905 354906 Cone Tip angle: 50° High accuracy type H .24" (6mm) .47" (12mm) .79" (20mm) 1.18" (30mm) 1.65" (42mm) Order No. — — 355129 — — * Standard accessory For CV-3000/4000 Unit: inch (mm) Small hole 996540 Tip angle: 20° Tungsten carbide 996541 Tip angle: 20° Tungsten carbide 996542 Tip angle: 20° Tungsten carbide For CV-1000/2000 Small hole (ø4.5mm or larger) (ø2.5mm or larger) 932693 Tip angle: 20° (one-sided cut) Tungsten carbide 932694 Tip angle: 20° (one-sided cut) Tungsten carbide (ø7mm or larger) 932695 Tip angle: 20° (one-sided cut) Tungsten carbide 15 Contracer Technical data Specifications Model CV-H628 Dimensions – CV-H628 Order No. 218-797A Type inch/mm Unit: inch (mm) Model Measuring range CV-H628 8" (200mm) 1" (25mm) .25µinch (0.00625µm) 5µinch (0.0125µm) (20 + 3L)µinch, [(0.5 + 0.003L)µm]* ±(20 + | 20H |)µinch, [±(0.5 + | 0.02H |)µm]** (11.8+2L)µinch, (0.3+0.002L)µm Downward Traversing direction Measuring force Maximum traceable angle Measuring speed Forward/backward 30mN (3gf) 60 degrees for upward/downward slope*** .0008"/s (0.02mm/s) to .08"/s (2mm/s), Can be specified by 7 steps. .004/s" (0.1mm/s) to 0.2"/s (5mm/s), Can be adjusted manually with a joystick box. .004"/s (0.1mm/s) to .2"/s (5mm/s), Can be adjusted manually with a joystick box. Via GPIB interface 10°C to 30°C 100V AC - 240V AC 150VA (at maximum) 30.1" x 17.7" x 35" (765 x 450 x 890mm) 9.8" x 15" x 11.8" (250 x 380 x 300mm) 44.5" x 24.8" x 30" (1130 x 630 x 760mm) X-axis Z-axis Resolution X-axis Z-axis Measuring X-axis accuracy (20°C) Z-axis Straightness of drive unit Stylus tip orientation Moving speed X-axis Column Digital data output Operating temperature Power supply Power consumption Dimensions Main unit (W x D xH ) Control unit Vibration isolation table Side desk Mass Main unit Control unit Vibration isolation table Side desk 24.4" x 37" x 47.2" (620 x 940 x 1200mm) 308 Ibs. (140kg) 15.4 Ibs. (7kg) 286 Ibs. (130kg) 88 Ibs. (40kg) * L = Traverse length (inch [mm]) ** H = Measuring height (within ±1inch [±25mm]) *** Depends on the workpiece surface condition. 16 Contracer Technical data Model CV-1000N2 CV-2000M4 Order No. 218-621A 218-641A Type inch/mm inch/mm Dimensions – CV-1000N2 Unit: inch (mm) Dimensions – CV-2000M4 Unit: inch (mm) Specifications Model Measuring range X-axis Z-axis X-axis Z-axis X-axis Z-axis Resolution Measuring accuracy Straightness Stylus tip orientation Traversing direction Measuring force Stylus traceable angle Stylus speed Digital data output Operating temperature Power supply Power consumption Dimensions Main unit (W x D x H) Display unit Mass Main unit Display unit CV-1000N2 CV-2000M4 2" (50mm) 4" (100mm) 1" (25mm) 1.5" (40mm) .008µinch (0.2µm) .016µinch (0.4µm) .02µinch (0.5µm) (138 + 20L)µinch [(3.5 + 0.02L)µm]* ±(138 + |157H | )µinch [±(3.5 + | 4H |/25)µm]** .14µinch / 2" .14µinch / 4" (3.5µm / 50mm) (3.5µm / 100mm) Downward Forward 10 to 30mN (1 to 3gf) Ascent: 77° (depends on the workpiece surface condition) Descent: 87° (depends on the workpiece surface condition) .008"/s (0.2mm/s) or .02"/s (0.5mm/s) for tracing .008"/s (0.2mm/s) or .04"/s (1mm/s) or manual feeding for retracing Via RS-232C interface 0°C to 40°C 100V AC - 240V AC 150VA (at maximum) 19.30" x 7.01" x 5.43" 23.62" x 17.71" x 18.80" (490 x 178 x 138mm) (600 x 450 x 740mm) 12.05" x 6.50" x 3.11" (306 x 165 x 79mm) 11 Ibs. (5kg) 255 Ibs. (115.8kg) 11 Ibs. (5kg) * L = Measuring length (inch [mm]) ** H = Measuring height from the horizontal (within ±.5inch [±12.5mm]) 17 Contracer Technical data Model CV-3000S4 CV-3000H4 CV-3000W4 CV-3000S8 CV-3000H8 CV-3000W8 CV-4000S4 CV-4000H4 CV-4000W4 CV-4000S8 CV-4000H8 CV-4000W8 Order No. 218-662A 218-663A 218-664A 218-667A 218-668A 218-669A 218-682A 218-683A 218-684A 218-687A 218-688A 218-689A Type inch/mm inch/mm inch/mm inch/mm inch/mm inch/mm inch/mm inch/mm inch/mm inch/mm inch/mm inch/mm Specifications Model Measuring range Resolution Measuring accuracy (20°C) CV-3000S4/4000S4 X-axis Z-axis X-axis Z-axis X-axis Z-axis Linearity of drive unit Drive unit vertical travel Drive unit inclinating range Stylus tip orientation Traversing direction Measuring force Maximum traceable angle Stylus speed Tracing Retracting Positioning Digital data output Operating temperature Power supply Power consumption Dimensions Main unit (W x D x H) Control unit Operation box Mass Main unit Control unit Operation box CV-3000W4/4000W4 CV-3000S8/4000S8 CV-3000H8/4000H8 8" (200mm) 2" (50mm) CV-3000W8/4000W8 .000002" (0.00005mm) CV-3000 models: .000008" (0.0002mm) CV-4000 models: .000002" (0.00005mm) CV-3000S4/H4/W4: ±(40+20L)µinch [±(1+2L/100)µm]* CV-3000S8/H8/W8: ±(40+20L)µinch [±(1+4L/200)µm]* CV-4000S4/H4/W4: ±(31+20L)µinch [±(0.8+2L/100)µm]* CV-4000S8/H8/W8: ±(31+20L)µinch [±(0.8+4L/200)µm]* CV-3000 models: ±(120+|40H|)µinch [±(3+|2H|/25)µm]** CV-4000 models: ±(31+|10H|)µinch [±(0.8+|0.5H|/25)µm]** 32µinch/4" (0.8µm/100mm) 80µinch/8" (2µm/200mm) 10" (250mm) 18" (450mm) 10" (250mm) 18" (450mm) ±45 degrees Downward/upward Forward/backward 30mN (3gf) 77 degrees for upward slope*** 87 degrees for downward slope*** .0008"/s (0.02mm/s) to .08"/s (2mm/s), Can be specified by 7 steps. .2"/s (5mm/s) .004"/s (0.1mm/s) to .2"/s (5mm/s), Can be adjusted manually with a operation box. Via RS-232C interface 15°C to 25°C 100V AC – 240V AC 150VA (at maximum) 29.17" x 17.7" x 35.63" 29.17" x 17.7" x 43.5" 44.02" x 17.7" x 43.5" 30.2" x 17.7" x 35.63" 30.2" x 17.7" x 43.5" 45.04" x 17.7" x 43.5" (741 x 450 x 905mm) (741 x 450 x 1105mm) (1118 x 450 x 1105mm) (767 x 450 x 905mm) (767 x 450 x 1105mm) (1144 x 450 x 1105mm) 7.1" x 15" x 11.8" (180 x 380 x 300mm) 9.6" x 4.6" x 3.1" (245 x 116 x 78mm) 308 lbs. (140kg) 330 lbs. (150kg) 330 lbs. (150kg) 319 lbs. (145kg) 341 lbs. (155kg) 341 lbs. (155kg) 14.3 lbs. (6.5kg) 1.76 lbs. (0.8kg) * L = Traverse length (inch [mm]) 18 CV-3000H4/4000H4 4" (100mm) 2" (50mm) **H = Measuring height (within ±1inch [±25mm]) ***Depends on the workpiece surface condition. Dimensions – CV-3000/4000 Unit: inch (mm) 19 Coordinate Measuring Machines Vision Measuring Systems Surface Roughness, Form and Contour Measurement Digital Scale and DRO Systems Optical Measuring Machines Sensor Systems Hardness Measuring Machines Small Tool Instruments and Data Management Made to Measure JSAQ-052 ISO 9001 Mitutoyo America Corporation Regional Offices: Michigan (734) 459-2810 Illinois (630) 978-5385 California (626) 961-9661 Massachusetts (978) 692-8765 Indiana (317) 577-6070 No. Carolina (704) 875-8332 www.mitutoyo.com © 2003 Mitutoyo America Corporation, Aurora IL We reserve the right to change specifications and prices without notice. 3B-11 • Printed in USA • August 2003
Similar documents
Contracer CV
1. Point measurement: Point, peak, contact, intersection, bisector-point (between elements/ pieces of measured data) 2. Line measurement: Line, tangent line, perpendicular, parallel line, bisector ...
More information