contracer - Measure-All

Transcription

contracer - Measure-All
Surface-, Form-, and Contour Measurement
CONTRACER ®
Bulletin No. 1667
Contour Measuring
Instruments
Mitutoyo’s Contracer CV Series
Powerful Lineup
That's digital!
All models feature a Z-axis with
integrated digital-scale detecting unit.
Mitutoyo’s Contracer CV Series is a high-accuracy
contour measuring instrument with a digital scale
on the X- and Z-axis. Digitization of the Z-axis
gives you the following:
• No need to calibrate the Z-axis according to
measurement magnification
• No need to change the Z-axis detection zone
according to measurement magnification
• High-accuracy measurement for largedisplacement contours
That’s Mitutoyo!
A wide selection of models designed
to make measuring easier, more
comfortable and more accurate!
2
Outstanding measurement support,
thanks to Windows® OS-compatible “FORMPAK®-1000”
Contour Analysis.
Windows® 95 / Windows® 98 / Windows® NT4.0 /
Windows®2000 is used as the OS. Program commands
can be accessed via icons and a powerful Help
function, making it easy for anyone to use…
even a novice!
Selection Guide
Contracer CV Series
Mitutoyo offers a range of models for every requirement.
There’s sure to be one that fits your needs!
CV-H628
■ X-axis/Z-axis measuring range: 8" (200mm)/1" (25mm)
■ Vertical travel:
■ Base size (W x D):
10" (250mm)
24" x 18" (600 x 450mm)
CV-3000W8 / CV-4000W8
■ X-axis/Z-axis measuring range: 8" (200mm)/2" (50mm)
■ Vertical travel:
■ Base size (W x D):
18" (450mm)
40" x 18" (1000 x 450mm)
CV-3000H8 / CV-4000H8
■ X-axis/Z-axis measuring range: 8" (200mm)/2" (50mm)
■ Vertical travel:
■ Base size (W x D):
18" (450mm)
24" x 18" (610 x 450mm)
CV-3000S8 / CV-4000S8
■ X-axis/Z-axis measuring range: 8" (200mm)/2" (50mm)
■ Vertical travel:
■ Base size (W x D):
10" (250mm)
24" x 18" (610 x 450mm)
CV-3000W4 / CV-4000W4
■ X-axis/Z-axis measuring range: 4" (100mm)/2" (50mm)
■ Vertical travel:
■ Base size (W x D):
18" (450mm)
40" x 18" (1000 x 450mm)
CV-3000H4 / CV-4000H4
CV-2000M4
■ X-axis/Z-axis measuring range: 4" (100mm)/2" (50mm)
■ X-axis/Z-axis measuring range: 4" (100mm)/1.5" (40mm)
■ Vertical travel:
■ Vertical travel:
■ Base size (W x D):
18" (450mm)
24" x 18" (610 x 450mm)
CV-3000S4 / CV-4000S4
■ Base size (W x D):
10" (250mm)
24" x 18" (610 x 450mm)
CV-1000N2
■ X-axis/Z-axis measuring range: 4" (100mm)/2" (50mm)
■ X-axis/Z-axis measuring range: 2" (50mm)/1" (25mm)
■ Vertical travel:
■ Vertical travel:
■ Base size (W x D):
10" (250mm)
24" x 18" (610 x 450mm)
■ Base size (W x D):
—
—
3
Contracer
X-axis resolution: .00000025" (0.00000625mm)
Z-axis resolution: .0000005" (0.0000125mm)
World-class resolution and accuracy (Z-axis)
Small-footprint design…
smart, simple operation!
The electronic unit is
housed within the
measuring unit’s
vibration isolator, and
the vertical side table is
a standard configuration
that houses the data
analysis unit.
CV-H628
with personal computer system
4
FEATURES
Equipped with the X- and Z-axis
Laser Holoscale
Principle of
Laser Holoscale
Mitutoyo’s holographic scale, which is based on the interference
phenomenon of diffracted light, is incorporated into the
detector as a measuring unit for the X- and Z-axes.The Laser
Holoscale offers the world’s highest level of resolution along
the X-axis .25µinch (0.00625µm), Z-axis .5µinch (0.0125µm)
over the entire measurement range of the X-axis at 8" (200
mm), and the Z-axis 1" (25 mm).
Laser Holoscale
Standard accessories
997123
12AAA567
354903
12AAC169
211-016
546-113
537976
178-052-1
178-016
355130
Pin gage and holder
Cone stylus
Ball stylus
Reversal mounting arm
Reference hemisphere
Dial tension gage
Carrying bolts
Digimatic XY leveling table with swivel
Leveling table
Machine cover
FORMPAK®-1000 software
is easy to operate, and capable of powerful
analysis, concurrently.
Gauge blocks
613192-221 (.2")
613194-221 (.4")
613201-221 (1")
User’s manual (1set), Fuse,Wrenches, Screw driver,
Power cord, GND wire
Gage blocks are provided with Grade K of /ISO/JIS/DIN or Grade 1of Federal Standard
5
Contracer
6
CV-3000S4
with personal
computer system
X-axis resolution: .000002" (0.00005mm)
Z-axis resolution: .000008" (0.0002mm)
CV-4000S4
with personal
computer system
X-axis resolution: .000002" (0.00005mm)
Z-axis resolution: .000002" (0.00005mm)
FEATURES
Featuring a digital scale unit installed
in the Z-axis detection unit (CV-3000 Series)
The CV-3000 Series, which uses a digital scale unit in its Z-axis
detection unit, achieves a resolution of .000008" (0.0002 mm)
at a full stroke of ±1" (±25 mm). And unlike conventional,
differential transformer units, there is no change in resolution
as the range of magnification changes.The result: a dramatic
improvement in operation and performance!
FORMPAK®-1000 software
is easy to operate, and capable of powerful
analysis, concurrently.
Ceramic guides have been employed
for abrasion resistance.
A dedicated control box for ease
of operation.
• The control box, which is independent of the main unit, gives
you remote control over positioning, measurement start/stop,
returning, and other key operations.
• The drive unit's up/down position and the X-axis traverse
can be fine-tuned under manual control.
Mitutoyo’s Holographic Scale delivers
super-high accuracy (CV-4000 Series)
• The new, top-of-the-line Holography Scale is based on the
interference phenomenon of diffracted light, ensuring the
absolute in accuracy. It allows dimensional measurement
at a resolution of .000002" (0.00005mm) over the entire
measurement range of 2" (50mm).
Standard accessories
354884
996506
546-113
178-043-1
178-053-1
211-016
537976
352637
998861
538333
Gauge blocks
High one-side cut stylus
Straight arm
Dial tension gage
Leveling table (CV-4000 only, for metric)
Leveling table (CV-4000 only, for inch/mm)
Symmetry calibration gage (CV-4000 only)
Carrying bolts
Lubricant
Pin gage (inch) and holder
Thread gage (p=.05")
(CV-3000)
611194-231 (.4")
611198-231 (.8")
611202-231 (2")
Gauge blocks (CV-4000)
Laser Holoscale
611194-221 (.4")
611198-221 (.8")
611202-221 (2")
User’s manual (1set), Fuse,Wrenches, Screw driver,
Connecting cables, Power cord, GND wire, Machine cover,
Driving cable assembly, Column cable assembly
Gage blocks are provided with Grade 0 of ISO/JIS/DIN or Grade 2 of Federal Standard
for CV-3000 and Grade K of ISO/JIS/DIN or Grade 1 of Federal Standard for CV-4000
7
Contracer
X-axis resolution: .000008" (0.0002mm)
Z-axis resolution: .000016" (0.0004mm)
Mitutoyo digitizes the X- and Z-axes over
the full range, giving you a wider range
of measurement with higher resolution.
No more reliance on measurement
magnifications!
The CV-1000 is portable and can
be carried to the machine-shop for
measurement of large workpieces.
Even at a site where a power source
may not be nearby, the CV-1000 can work
with the optional display unit (built-in rechargeable battery).
X-axis resolution: .000008" (0.0002mm)
Z-axis resolution: .00002" (0.0005mm)
CV-2000M4
with personal
computer system
8
FEATURES
Display unit and XY plotter
Optional stand
Icons and graphics on the LCD and touch panel make it
easy for anyone — even a novice — to perform key analysis
operations.The contour profile can be confirmed with the
display unit prior to output to an XY plotter.
The Contracer CV-1000N2
can be attached to the
optional stand.
FORMPAK®-1000 software
Connected to a personal computer, the FORMPAK-1000
contour analysis program provides various modes of
measurement and analysis.When connected to an XY plotter,
the contour profile can be checked with the display unit prior
to output.
System diagram
Arc scale on Z-axis
* The following plotters are recommended
• MP5100-51 (Graphtec)
• Y-1 x 50 (DXY-1150, 1250, 1350) (Roland)
Standard accessories
357651
354884
935113
546-113
538333
Gauge blocks
AC adapter
High one-side cut stylus
Straight arm
Dial tension gage
Thread gage (p=.5")
(CV-1000)
611192-231 (.2")
611196-231 (.6")
611194-231 (.4")
611201-231 (1")
Gauge blocks (CV-2000)
611194-231 (.4")
611198-231 (.8")
611201-231 (1")
User’s manual (1set),Wrenches, Screw driver, Power cord,
Connecting cables
Gage blocks are provided with Grade 2 of ISO/JIS/DIN or Federal Standard
9
Software that’s easy to operate,
and capable of powerful analysis, concurrently.
FORMPAK-1000 is a powerful program that
has an enhanced user interface, including mouse
operation, a variety of graphic displays, and online
help which is convenient if the user experiences
a problem. In addition to being able to perform
dimensional measurements such as angle, radius,
and distance measurements, the contour tolerancing
function for evaluating "form" and the report
creation function for outputting measurement
results in a specific format are provided as standard,
ensuring both ease of operation and powerful
analysis capabilities.
Realtime
measurement window
Analysis result window
Online help function
Report creation function
The appropriate help window displaying operating procedures,
the definition of icons, etc., can be opened as required.This
function eliminates the need to find information in the manual.
Geometric measured data, measurement conditions, contour
tolerancing results, and comments can be laid out as desired and
printed out in a report. Once a layout has been saved, it can be
reused as a glossary if the same measurement is made. A report
can be printed in A3 size or from a color printer (option).
Printout
examples
Layout edit
window
10
User customization function
External output function
The size and position of operation buttons on a window
can be modified as desired.This function allows the counter
display, each window, the location of analysis command
buttons, or the display color of measured data and auxiliary
lines to be modified.
Calculation results and tolerancing results can be downloaded
in a readable format to commercial spreadsheet software.This
function increases processing capabilities including statistical
calculation, saving, and management of measurement results.
It also allows measured point group data to be output in
the text format.
Contour tolerancing function
This function compares measured data as “form” with nominal
data, displays the deviation, and then stores it, being different
from dimensional measurement of angle, radius, etc. In addition
to values obtained from an ideal contour in a CAD drawing,
nominal values can be created by converting the measured
data of a master.
Contour tolerancing flow
Developed error
display window
Tolerancing
result window
Specifications
Operation commands
1. Point measurement: Point, peak, contact, intersection, bisector-point
(between elements/pieces of measured data)
2. Line measurement: Line, tangent line, perpendicular, parallel line, bisector
3. Circle measurement: Circle (multi-points, range, center and radius)
4. Position, difference: Coordinate difference, true position judgment
5. Distance, angle: Distance, groove length, step, pitch, distance reference, angle
6. Coordinate system setup: Origin setup, coordinate system rotation
7. Calculation, statistics: Arithmetic calculation, absolute value, square root,
maximum value, minimum value, mean, sum, standard deviation, unbiased
standard deviation, area
8. Editing of measured points: Deletion, translation, rotation, mirror image,
positioning, combination, separation, projection
Contour tolerancing
1. Nominal value data creation
• Function specification (line/circle/aspheric surface, etc.), CAD input
(IGES, DXF), measured data conversion, text file conversion
• Tolerancing direction setup (normal direction/X-axis direction/Z-axis direction)
2. Reference coordinate system translation/rotation
3. Best-fit
• X-axis translation, Z-axis translation, rotating direction, several kinds in combination
4. Nominal value tolerancing
5. Results display
• Result list display, graphic display
Special functions
a. Sub-part program: Calculation procedure can be registered as a Sub-part
program. The Sub-part program can be integrated into a part program facilitating
measurement of batch of workpieces.
b. Measured data/conditions saving: Measured data and analysis procedure can be
saved in the hard disk.
c. Layout Edit function: A measured profile, measurement conditions, etc., can be
arranged in a form and laid out as desired. This function allows an original result
report to be created and printed out.
d. External output of files: Analysis results can be output in the CSV format, and
therefore, can be easily accessed by commercial spreadsheet software. Also,
measured data (point group data) can be output in the ASCII code.
e. Part program: Measurement procedures complete with measurement, analysis,
contour tolerance judgment, print, and save as a file, can be registered as a part
program. The part program can be executed for automatic measurements.
f. Polar coordinate development display: Develops a circular form on to the polar
coordinate system, where the range for circle calculation can be specified.
11
Optional Accessories
Rugged tables
Rotary vises
Cross-travel table
Rotary vise
• Table top: 11" x 7" (280 x 180mm) • Two-slide jaw type.
• XY travel: 4" x 2" (100 x 50mm)
• Max. workpiece size: ø2.4" (60mm)
• Minimum reading: 1°
Rotary table
Rotary table
• Table top: ø5.7" (146mm DIA)
• Minimum reading: 2'
• Holder with clamp (176-107)
can be mounted.
Holder with clamp
Holder with clamp
• Used with a cross-travel table or
rugged table.
• Max. workpiece height: 1.3" (35mm)
218-001 (mm)
218-011 (inch)
176-107
218-003
Cross-travel table
• Table top: 11" x 6" (280 x 152mm) Rotary vise
• One-slide jaw type.
• XY travel: 2" x 1" (50 x 25mm)
• Max. workpiece size: ø2.4" (60mm)
• Minimum reading: 5°
172-196
Leveling tables
XY leveling table with swivel
• Table top: 5" x 4" (130 x 100mm)
• Leveling range: ±1.5°
• XY travel: ±.5" (±12.5mm)
Center supports
Swivel center support
• Max. workpiece diameter:
3.1" (80mm)*
*2.5" (65mm) when swiveled 10°
• Max. workpiece length: 5.5" (140mm)
218-041 (mm)
218-051 (inch)
Rugged table
172-144
• Table top: 11" x 7" (280 x 180mm)
V-blocks
• Provided with T-grooves for
mounting workpiece fixtures.
V-block with clamp
• Used with a cross-travel table
or rugged table.
• Max. workpiece diameter:
2" (50mm)
218-002
172-197
178-043-1 (mm)
178-053-1 (inch)
Center support
• Max. workpiece diameter:
4.7" (120mm)
• 2.3" (60mm) riser is optional
(172-143).
Digimatic XY leveling table
with swivel
• Table top: 5" x 4" (130 x 100mm)
• Leveling range: ±1.5°
• XY travel: ±.5" (±12.5mm)
172-142
Center support riser
• Used with a center support.
• Max. workpiece diameter:
9.4" (240mm)
Vibrator isolator
Vibration isolator
• Dimensions (W x D x H):
30" x 22" x 2.3"
(750 x 550 x 59mm)
• Stand is optional (178-024).
172-234
V-block with clamp
• Used with a cross-travel table
or rugged table.
• Max. workpiece diameter:
1" (25mm)
178-042-1 (mm)
178-052-1 (inch/mm)
Leveling table
• Table top: 5" x 4" (130 x 100mm)
• Leveling range: ±1.5°
• Height: 1.57" (40mm)
178-023
172-143
Vise
Precision vise
• Max. workpiece size: 1.42" (36mm)
• Can be mounted on a leveling table.
172-378
178-016
12
178-019
Optional Accessories
V-block
V-block
• Workpiece diameter:
.04" to 6.3" (1mm to 160mm)
• Can be mounted on a leveling
table.
Symmetry calibration gages
Used to calibrate a slight circular error due to attachment errors of the
stylus and arm. These gages are usually required to perform high-accuracy
measurement of a lens, etc.
Symmetry calibration gage
(angle measurement type)
Symmetry calibration gage
(sphere measurement type)
Others
CV-H628
Windshield cover (12AAC168)
CV-1000/2000
Display unit (218-341■)
■ Suffix: A for 120V, D for 220V,
E for 240V or non for 100V
CV-1000
Measuring stand (218-024)
RAM card
997996
211-016
(12AAA841)
998291
Pin gage unit (CV-1000/2000)
998862 (mm)
998861 (inch)
13
Arms
Optional Accessories
For CV-3000/4000
Unit: inch (mm)
Straight type
996504
996505
996506*
996507
996508
Eccentric type
for .24" (6mm) high stylus
for .47" (12mm) high stylus
for .79" (20mm) high stylus
for 1.18" (30mm) high stylus
for 1.65" (42mm) high stylus
996509
996510
996511
996512
996513
For small hole stylus
for .24" (6mm) high stylus
for .47" (12mm) high stylus
for .79" (20mm) high stylus
for 1.18" (30mm) high stylus
for 1.65" (42mm) high stylus
996514
*Standard accessory
For CV-1000/2000
Unit: inch (mm)
Straight type
935111
935112
935113*
935114
935115
Eccentric type
for .24" (6mm) high stylus
for .47" (12mm) high stylus
for .79" (20mm) high stylus
for 1.18" (30mm) high stylus
for 1.65" (42mm) high stylus
935116
935117
935118
935119
935120
For small hole stylus
935110
for .24" (6mm) high stylus
for .47" (12mm) high stylus
for .79" (20mm) high stylus
for 1.18" (30mm) high stylus
for 1.65" (42mm) high stylus
*Standard accessory
ARM and STYLUS SET
For CV-3000/4000
996660
Consists of three special arms and five special styli.
14
Order No.
996660
Components
in set
996504 Straight arm for .24" (6mm) high stylus
996511 Eccentric arm for .79" (20mm) high stylus
996514 Arm for small hole stylus
354882 .24" (6mm) high one-sided cut stylus
354889 .79" (20mm) high intersecting cut stylus
354894 .79" (20mm) high cone stylus
996540 Small hole stylus
996542 Small hole stylus
Styli
Optional Accessories
For CV-3000/4000, CV-1000/2000, (CV-H628)
One-sided cut
Intersecting cut
Tip angle: 20°
Tungsten carbide
Tip angle: 12°
Tungsten carbide
H
.24" (6mm)
.47" (12mm)
.79" (20mm)
1.18" (30mm)
1.65" (42mm)
Order No.
354882
354883 (CV-H628)
354884*
354885
354886
H
.24" (6mm)
.47" (12mm)
.79" (20mm)
1.18" (30mm)
1.65" (42mm)
Order No.
354887
354888 (CV-H628)
354889
354890
354891
* CV-1000/2000/3000/4000 Standard accessory
Tip angle: 20°
Edge width: 3mm
Tungsten carbide
Order No.
354897
354898 (CV-H628)
354899
354900
354901
Tip angle: 30°
Sapphire or Tungsten carbide
H
Order No.
Sapphire tip
.24" (6mm)
354887
.47" (12mm) 354888
(CV-H628)
.79" (20mm) 354889
1.18" (30mm) 354890
1.65" (42mm) 354891
Ball
Knife edge
H
.24" (6mm)
.47" (12mm)
.79" (20mm)
1.18" (30mm)
1.65" (42mm)
For small hole stylus
12AAA568
12AAA569
12AAA570
Diamond
Ball diameter: 1mm
Tungsten carbide
H
.24" (6mm)
.47" (12mm)
.79" (20mm)
1.18" (30mm)
1.65" (42mm)
Order No.
Tungsten tip
12AAA566
12AAA567
Order No.
354902
354903 (CV-H628)*
354904
354905
354906
Cone Tip angle: 50°
High accuracy type
H
.24" (6mm)
.47" (12mm)
.79" (20mm)
1.18" (30mm)
1.65" (42mm)
Order No.
—
—
355129
—
—
* Standard accessory
For CV-3000/4000
Unit: inch (mm)
Small hole
996540
Tip angle: 20°
Tungsten carbide
996541
Tip angle: 20°
Tungsten carbide
996542
Tip angle: 20°
Tungsten carbide
For CV-1000/2000
Small hole
(ø4.5mm or larger)
(ø2.5mm or larger)
932693
Tip angle: 20° (one-sided cut)
Tungsten carbide
932694
Tip angle: 20° (one-sided cut)
Tungsten carbide
(ø7mm or larger)
932695
Tip angle: 20°
(one-sided cut)
Tungsten carbide
15
Contracer
Technical data
Specifications
Model
CV-H628
Dimensions – CV-H628
Order No.
218-797A
Type
inch/mm
Unit: inch (mm)
Model
Measuring
range
CV-H628
8" (200mm)
1" (25mm)
.25µinch (0.00625µm)
5µinch (0.0125µm)
(20 + 3L)µinch, [(0.5 + 0.003L)µm]*
±(20 + | 20H |)µinch, [±(0.5 + | 0.02H |)µm]**
(11.8+2L)µinch, (0.3+0.002L)µm
Downward
Traversing direction
Measuring force
Maximum traceable angle
Measuring speed
Forward/backward
30mN (3gf)
60 degrees for upward/downward slope***
.0008"/s (0.02mm/s) to .08"/s (2mm/s),
Can be specified by 7 steps.
.004/s" (0.1mm/s) to 0.2"/s (5mm/s),
Can be adjusted manually with a joystick box.
.004"/s (0.1mm/s) to .2"/s (5mm/s),
Can be adjusted manually with a joystick box.
Via GPIB interface
10°C to 30°C
100V AC - 240V AC
150VA (at maximum)
30.1" x 17.7" x 35" (765 x 450 x 890mm)
9.8" x 15" x 11.8" (250 x 380 x 300mm)
44.5" x 24.8" x 30" (1130 x 630 x 760mm)
X-axis
Z-axis
Resolution
X-axis
Z-axis
Measuring
X-axis
accuracy (20°C)
Z-axis
Straightness of drive unit
Stylus tip orientation
Moving speed
X-axis
Column
Digital data output
Operating temperature
Power supply
Power consumption
Dimensions
Main unit
(W x D xH ) Control unit
Vibration
isolation table
Side desk
Mass
Main unit
Control unit
Vibration
isolation table
Side desk
24.4" x 37" x 47.2" (620 x 940 x 1200mm)
308 Ibs. (140kg)
15.4 Ibs. (7kg)
286 Ibs. (130kg)
88 Ibs. (40kg)
* L = Traverse length (inch [mm])
** H = Measuring height (within ±1inch [±25mm])
*** Depends on the workpiece surface condition.
16
Contracer
Technical data
Model
CV-1000N2
CV-2000M4
Order No.
218-621A
218-641A
Type
inch/mm
inch/mm
Dimensions – CV-1000N2
Unit: inch (mm)
Dimensions – CV-2000M4
Unit: inch (mm)
Specifications
Model
Measuring
range
X-axis
Z-axis
X-axis
Z-axis
X-axis
Z-axis
Resolution
Measuring
accuracy
Straightness
Stylus tip orientation
Traversing direction
Measuring force
Stylus traceable angle
Stylus speed
Digital data output
Operating temperature
Power supply
Power consumption
Dimensions Main unit
(W x D x H)
Display unit
Mass
Main unit
Display unit
CV-1000N2
CV-2000M4
2" (50mm)
4" (100mm)
1" (25mm)
1.5" (40mm)
.008µinch (0.2µm)
.016µinch (0.4µm)
.02µinch (0.5µm)
(138 + 20L)µinch [(3.5 + 0.02L)µm]*
±(138 + |157H | )µinch [±(3.5 + | 4H |/25)µm]**
.14µinch / 2"
.14µinch / 4"
(3.5µm / 50mm)
(3.5µm / 100mm)
Downward
Forward
10 to 30mN (1 to 3gf)
Ascent: 77°
(depends on the workpiece surface condition)
Descent: 87°
(depends on the workpiece surface condition)
.008"/s (0.2mm/s) or .02"/s (0.5mm/s) for tracing
.008"/s (0.2mm/s) or .04"/s (1mm/s)
or manual feeding for retracing
Via RS-232C interface
0°C to 40°C
100V AC - 240V AC
150VA (at maximum)
19.30" x 7.01" x 5.43" 23.62" x 17.71" x 18.80"
(490 x 178 x 138mm) (600 x 450 x 740mm)
12.05" x 6.50" x 3.11"
(306 x 165 x 79mm)
11 Ibs. (5kg)
255 Ibs. (115.8kg)
11 Ibs. (5kg)
* L = Measuring length (inch [mm])
** H = Measuring height from the horizontal (within ±.5inch [±12.5mm])
17
Contracer
Technical data
Model
CV-3000S4
CV-3000H4
CV-3000W4
CV-3000S8
CV-3000H8
CV-3000W8
CV-4000S4
CV-4000H4
CV-4000W4
CV-4000S8
CV-4000H8
CV-4000W8
Order No.
218-662A
218-663A
218-664A
218-667A
218-668A
218-669A
218-682A
218-683A
218-684A
218-687A
218-688A
218-689A
Type
inch/mm
inch/mm
inch/mm
inch/mm
inch/mm
inch/mm
inch/mm
inch/mm
inch/mm
inch/mm
inch/mm
inch/mm
Specifications
Model
Measuring
range
Resolution
Measuring
accuracy (20°C)
CV-3000S4/4000S4
X-axis
Z-axis
X-axis
Z-axis
X-axis
Z-axis
Linearity of drive unit
Drive unit vertical travel
Drive unit inclinating range
Stylus tip orientation
Traversing direction
Measuring force
Maximum traceable angle
Stylus speed
Tracing
Retracting
Positioning
Digital data output
Operating temperature
Power supply
Power consumption
Dimensions
Main unit
(W x D x H)
Control unit
Operation box
Mass
Main unit
Control unit
Operation box
CV-3000W4/4000W4
CV-3000S8/4000S8
CV-3000H8/4000H8
8" (200mm)
2" (50mm)
CV-3000W8/4000W8
.000002" (0.00005mm)
CV-3000 models: .000008" (0.0002mm) CV-4000 models: .000002" (0.00005mm)
CV-3000S4/H4/W4: ±(40+20L)µinch [±(1+2L/100)µm]* CV-3000S8/H8/W8: ±(40+20L)µinch [±(1+4L/200)µm]*
CV-4000S4/H4/W4: ±(31+20L)µinch [±(0.8+2L/100)µm]* CV-4000S8/H8/W8: ±(31+20L)µinch [±(0.8+4L/200)µm]*
CV-3000 models: ±(120+|40H|)µinch [±(3+|2H|/25)µm]** CV-4000 models: ±(31+|10H|)µinch [±(0.8+|0.5H|/25)µm]**
32µinch/4" (0.8µm/100mm)
80µinch/8" (2µm/200mm)
10" (250mm)
18" (450mm)
10" (250mm)
18" (450mm)
±45 degrees
Downward/upward
Forward/backward
30mN (3gf)
77 degrees for upward slope***
87 degrees for downward slope***
.0008"/s (0.02mm/s) to .08"/s (2mm/s), Can be specified by 7 steps.
.2"/s (5mm/s)
.004"/s (0.1mm/s) to .2"/s (5mm/s), Can be adjusted manually with a operation box.
Via RS-232C interface
15°C to 25°C
100V AC – 240V AC
150VA (at maximum)
29.17" x 17.7" x 35.63" 29.17" x 17.7" x 43.5" 44.02" x 17.7" x 43.5"
30.2" x 17.7" x 35.63" 30.2" x 17.7" x 43.5"
45.04" x 17.7" x 43.5"
(741 x 450 x 905mm) (741 x 450 x 1105mm) (1118 x 450 x 1105mm) (767 x 450 x 905mm) (767 x 450 x 1105mm) (1144 x 450 x 1105mm)
7.1" x 15" x 11.8" (180 x 380 x 300mm)
9.6" x 4.6" x 3.1" (245 x 116 x 78mm)
308 lbs. (140kg)
330 lbs. (150kg)
330 lbs. (150kg)
319 lbs. (145kg)
341 lbs. (155kg)
341 lbs. (155kg)
14.3 lbs. (6.5kg)
1.76 lbs. (0.8kg)
* L = Traverse length (inch [mm])
18
CV-3000H4/4000H4
4" (100mm)
2" (50mm)
**H = Measuring height (within ±1inch [±25mm])
***Depends on the workpiece surface condition.
Dimensions – CV-3000/4000
Unit: inch (mm)
19
Coordinate Measuring Machines
Vision Measuring Systems
Surface Roughness, Form and
Contour Measurement
Digital Scale and DRO Systems
Optical Measuring Machines
Sensor Systems
Hardness Measuring Machines
Small Tool Instruments and
Data Management
Made to Measure
JSAQ-052
ISO 9001
Mitutoyo America Corporation
Regional Offices:
Michigan (734) 459-2810
Illinois (630) 978-5385
California (626) 961-9661
Massachusetts (978) 692-8765
Indiana (317) 577-6070
No. Carolina (704) 875-8332
www.mitutoyo.com
© 2003 Mitutoyo America Corporation, Aurora IL
We reserve the right to change specifications and prices without notice.
3B-11 • Printed in USA • August 2003

Similar documents

Contracer CV

Contracer CV 1. Point measurement: Point, peak, contact, intersection, bisector-point (between elements/ pieces of measured data) 2. Line measurement: Line, tangent line, perpendicular, parallel line, bisector ...

More information

CONTRACER CV-2100 Series

CONTRACER CV-2100 Series 218-001 (mm), 218-011 (inch)

More information