The INTACT Filler
Transcription
The INTACT Filler
MEDIntegrityTM 201 Housatonic Avenue New Milford, CT 06776 860.350.1900 MEDInstill Bridges Physics and Microbiology to Engineer the Compliance of Complete Sterile Transfer Systems Turn-Key MFG Lines 2013-14 Regulatory Dispensing Filling INTACT Fill for Topical Non-Preserved at Encube 2011 2007-09 2001-03 1987 STERILITY & COMPLIANCE Licenses INTACT Closed Vial Licenses INTACT Valve MEDInstill & founded by Daniel Py, MD, ScD INTACT Valve “New Standard” for Multi-Dose Dairy Non-Refrigerated EMA Vaccine Approval GSK Synflorix DMF Registered at FDA Qualification PATH Validation for • WHO • B. Gates Foundation • Homeland Security INTACT DMF For DSL Fast-Track 2 LACF Acceptances Over 400 patents granted 02 MEDInstill Technology Platforms * = Pall Exclusive Intact™ Technologies (Platforms) Intact™ Modular Filler Intact™ Products & Services + Filling Mini Intact™ Modular Filler * In-line Sterilization + Container sterilization Dispensing Devices * + Universal Closure Connectors DROC Multiple Dose Syringe * SCOT * Baby bottle Eye Dropper Pouch * Markets • Pharma/Biotech • Nutrition & Beverages • Cosmetics • Compounding Home Care Hospitals • Pharma/Biotech • Nutrition & Beverages • Cosmetics • Pharma/Biotech • Nutrition & Beverages • Cosmetics • Home • Hospitals *Device may be single-dose or multi-dose * • Pharma/Biotech • Nutrition & Beverages • Cosmetics • Home • Hospitals Public Service Announcement MEDInstill has licensed to Pall the SCOT Multi-Use Connector Samples available now MEDInstill and Pall own the Joint Venture, MEDIntegrity to commercialize the INTACT CNC Sterile Filler Schedule trials now EMA Approval of 1st Generation INTACT (DMF filed at FDA) (Parenteral) FDA Submission this year (Parenteral) TM MEDIntegrity Platform is the Intact CNC Filler The IntactTM CNC is a scalable platform for the sterile fill of high value biopharmaceutical, cell therapy and pharmaceutical fluids utilizing a disposable fully closed needle and closed septum format in controlled non-classified manufacturing space. CNC = Controlled-Non-Classified environment • Lock-in / Lock-out • Basic Gowning (Hairnet, gloves, lab coat) 05 INTACT Filler Enables Protein Therapeutic Disposable Platform to be Vial-to-Vial INTACT CNC Sterile Filler Implementation Strategy for Complete Single Use Processing for Biologics, David Pollard, Merck & Co. Inc., IBC Single-Use Conference, 2011 INTACT Filler Enables Cell Therapy Disposable Platforms to be Vial-to-Vial Mini-INTACT Sterile Filler SCOT RSS Multi-Use Sterile Connector INTACT CNC Sterile Filler The INTACT CNC Filler Primary advantages: (Value Proposition) Highest safety 100% closed systems Capital avoidance Reduce facility requirements by hundred million(s) $ Reduce line requirements by tens of millions $ Time to market Reduce build-to-commission time by at least 2 years Reduced operating costs At least $4-6M/yr per line Process flexibility One machine for multiple products, volumes, devices Primary Uses: Repetitive large & small scale sterile fill in CNC environment INTACT CNC Single Module CNC = Controlled Non-Classified, (ISO 8 or Class 100,000) Loading Plate for INTACTTM Pouches, Vials or Multi-Dose Vials Montrac runs through the INTACT CNC Filling Modules(S) TM The Intact CNC is a Breakthrough Sterile Fill Technology with Validated Performance INTACT CNC Fill is validated to meet high performance thresholds: • Robust microbial integrity / Complete exclusion of bioburden • Validation of sterile transfer at 6 log challenge • >165,000 sterile media fills at MEDInstill in 2013 • > 90,000 planned this year at customer sites • Consolidating kit & device validation package per CURRENT industry standards E.P.3.1.9 JP 59 USP 88 Class VI Cytotox ISO 10993 Hemolysis ISO 1099 USP 381 USP661 USP 788 Pyrogen LAL/Endotoxin L/E (per BPSA) ADCF Certifications 010 The INTACT Filler “Kit” is Multi-Use and Disposable SCOT Connector ISCON Needle (To Fill Reservoir or surge vessel) (To filled Device) INTACT Fill Head ISCON Needles (Caps On) INTACT Devices from MEDInstill INTACT Value Proposition Highest Safety INTACT Provides Highest Safety at Lowest Cost Class 100 12G 12G 12G Class 100,000 12G 385,000X Safety Increase CapEx ($60M - $150M) For 2ml Vial ISO 5 CR = 5/10,000/1hr Total System Exposure (mm2) Aseptic Open 12g Needle + 2ml Open Vial Aseptic Cannula + Vial + Stopper Aseptic Cannula + Closed Vial Closed Needle + Closed Vial 173 32 Safety Index 1/Total Exposure (mm2) (Needle + Vial + Stopper) 4.5 x 10-4 CR = 1/10,000/1hr ISO 7 Aseptic Open 12g Needle + 2ml Closed Vial Clean Fill, Preserved INTACT CNC Closed 12g ISCON + 2ml Closed Vial CR = 1/10,000,000/1hr ISO 8 6 x10-3 3 x10-2 2 x103 Safety Index (2ml Vial) Contamination Risk (CR) is function of: Surface exposure Exposure duration INTACT Provides Unmatched Safety for Preservative-Free Multi-Dose Devices The INTACT dispensing valve “utilizes an anti-contamination visco-elastic valve which uses a stress differential effect to force out any residue and prevent microbial ingress.” (PATH, Sept. 30, 2013. “Review of multi-dose primary packaging and delivery systems for vaccines without preservative.”) The INTACT Anti-Contamination Valve For Multi-Dose Dispensing PATH = Program for the Appropriate Technology in Health Validation of Safety • Link to microbial validation data • Link to particle validation data • Link to L/E data INTACT Value Proposition Lowest Capital Requirements Scenario 1: 6ml Devices / 3ml fill Assumptions Sales = 20,000,000 vials per year Depreciation capital / yr Asceptic in Existing Facility not fully depreciatedShifts INTACT is 3 Module Hr. per shift Total hr. / day Time to Market (Mo.) Aseptic INTACT FTE / Shift 18 2 Days / Yr Source/deliver filler 4 1 $ FTE / Day Install/Qualify filler 12 9 Direct labor / yr $ Validate filler TOTAL (Mo) 34 12 Devices/min Theoretic output / yr Uptime Downtime Actual output / yr Prep space for Fill Hardware (ft2) (Class 10000 for Aseptic, CNC for INTACT Value Concepts INTACT) Reduced capital Prep space cost/ft2 Reduced time to market Space for Fill Hardware (ft2) Reduced risk of contamination (Class 100 for Aseptic, CNC for INTACT) Reduced labor Cost fill hardware space (ft2) Reduced HVAC hardware Total cost space for filler Increase facility effiency (Reduced downtime) Depreciation filler space / yr Cost HVAC / yr Eliminate SIP / CIP Filler hardware Eliminate HVAC validation Depreciation filler/yr Reduce costs SIP/CIP Hardware Plumbing cost Space for SIP/CIP (ft2) Cost SIP/CIP space (ft2) Total cost SIP/SIP space Depreciation SIP/CIP space Cost SIP/CIP Validation / yr QA/QC/Maintenance SIP/CIP /yr Waste water treatment structure Space for WIFI (ft2) Total cost WIFI space Depreciation WIFI space (ft2) WIFI hardware Depreciation WIFI hardware QA/QC/Maintenance WIFI /yr Total /Yr Distilling the Value Proposition Aseptic 0.1 2 8 16 4 250 $1,000 2,000,000.00 200 48,000,000 49% 51% 23,298,000 INTACT Delta Cap 0.1 1 8 8 2 250 $1,000 $500,000 240 28,800,000 82% 18% 23,726,400 1,000 1,000 $1,300 $300 2,000 1,000 Delta Ops/yr $1,500,000 $1,600 $300 $4,500,000 $600,000 $3,900,000 $450,000 $60,000 $390,000 $300,000 $0 $300,000 $9,000,000 $6,000,000 $3,000,000 $1,800,000 $1,200,000 $600,000 $3,000,000 0 1,000 0 $300 $300 $3,300,000 $0 $3,300,000 $330,000 $0 $330,000 $500,000 $0 $500,000 $200,000 $0 $200,000 $800,000 $0 $800,000 1000 0 $300,000 $0 $300,000 $30,000 $0 $30,000 $3,000,000 $0 $3,000,000 $600,000 $0 $600,000 $200,000 $0 $200,000 Total /Yr $14,300,000 $4,650,000 Validation of Cost Models • Link to cost models • Link to case studies INTACT Value Proposition Fastest Time to Market Time to Market (Mo.) Aseptic INTACT Source/deliver filler 18 2 Install/Qualify filler 4 1 Validate filler 12 9 34 12 TOTAL (Mo) Confidential INTACT Fill Reduces Time to Market Design INTACT Filler Build & Deliver <2 months (See case study) Design INTACT Facility (Existing CNC) Install & SAT 1 Week (See Case Study) INTACT Fill Reduces Time to Market Remote Location: Design, Build, Install & SAT A MEDInstill Placement Confidential Stainless Steel Reservoir Conveyor Open for the Reservoir Passage Peristaltic Pumps on INTACT Kits Stainless Steel Reservoir Confidential The 1st Non-Preserved Dermatologic Cream Manufacturing in the World • Delivered in less than 2 months from PO • Installation & SAT less than 1 week • At a fraction of an aseptic line cost Confidential INTACT Value Proposition Lowest Cost of Goods Cost Savings From Class “C” to CNC Savings per year in bulk drug substance facility with 180 operators, 15,000 ft2 class ’C’ space versus controlled not classified (CNC), air changes from 30 to 10 per hour and humidity ranges from 45% to 60%. Source: Challenging the Cleanroom Paradigm for Biopharmaceutical Manufacturing of Bulk Drug Substances. Aug 1, 2011 / BioPharm International, Volume 24, Issue 7. By: Simon Chalk, Scott Probst, Paul Gil, Tim Palberg, Matt Kennedy, Joe Rogalewicz, Jeff Johnson, Ken Green Cost Savings of INTACT Devices Eliminates all labor, capital requirements, process validation, utilities and risk associated with traditional vial (or device): • • • • • • • Vial (or device) sterilization WIFI Rinse Hot air tunnel Stopper sterilization Siliconization Stopper seal Stopper crimping Customer Study 1 Module INTACT Filler in Existing Building CONVENTIONAL DEDICATED VIAL FILLING SYSTEM IN AN ISOLATOR CONVENTIONAL SYRINGE FILLING SYSTEM IN AN ISOLATOR Capex $3M $3.8M $5M Throughput / minute Up to 120 (10ml Vials) Up to 60 (1 to 3ml Syringe) Up to 40 (1 to 10 ml Vials & Syringes) Uptime 40% 40% 85% Annual Volume / shift (250 days) 6M 5M 8M CNC Pilot Filler Customer Study 3 Module INTACT Filler in a Existing Building CONVENTIONAL Aseptic Filler CNC 3-Module Filler Capex + Peripherals $10M $10M Throughput / minute Up to 500 (10ml Vials) Up to 480 (1 to 10 ml Vials & Syringes) Uptime 40% 80% Annual Volume / shift (250 days) 25M 49M Customer Study 3 Module INTACT Filler in a New Building CONVENTIONAL Aseptic Filler CNC 3-Module Filler Capex + Peripherals $10M $10M Capex Suite $8M $2M Capex Building $60M $5M Throughput / minute Up to 500 (10ml Vials) Up to 480 (1 to 10 ml Vials & Syringes) Uptime 40% 80% Annual Volume / shift (250 days) 25M 49M Validation of Cost Models • Link to cost models & case studies INTACT Value Proposition Unmatched Flexibility Same Filler for Multiple MEDInstill Devices IntactTM Filling Head (“Kit”) ( ISCON , Tubing, SCOT Connector) INTACT Bottle INTACT Pouches INTACT Multi-Dose INTACT Vials The INTACT filler is quickly converted from one product to another and one INTACT device to another. The INTACT Multi-Dose device adds exponential value The INTACT Filler Series CNC 3 module in double line filler Generation of Filler CNC 3 module Filler CNC 1 module Filler CNC Mini-Filler 4 3 Large Commercial Volumes 2 Medium to Large Commercial Volumes 1 Validation, Pilot Plant, R&D, Launch & Medium Volumes + R&D, Qualification ++++ Volume / year The INTACT Fill Technology is Scalable CNC Pilot Filler CNC Filler / 3 Modules CNC Filler / 3 Modules CNC Filler / 3 Modules CNC Filler / 3 Modules Containers / Vehicle 4 4 12 32 40 Device per Line 4 4 6 8 10 Number of Rows 1 1 2 4 4 Production Rate / min 40 80 240 640 800 Production Rate / hour 2,400 4,800 14,400 38,400 48,000 4 8 24 65 82 Annual Production Rate / year/shift (M) Note: 10ml Device Assumption Fill Kits Installation in <10’ INTACT ISCON Needle Ready to be uncapped by 1st vehicle in closed canopy Multiple MEDInstill INTACT Devices in Same Filler Thank you.