real nitrate sensor
Transcription
real nitrate sensor
REAL NITRATE SENSOR GL series Specification Sheet REAL NITRATE SENSOR Monitoring nitrates in real-time for drinking water and wastewater is straight forward and affordable with Real Tech’s nitrate sensor. Using the UV absorption measurement principle, precise, accurate and reliable data can be obtained without the use of reagents or complex sample preparation. This simple and effective method saves time and labour, providing a practical solution for many real-time nitrate monitoring applications. Applications • Groundwater and surface water monitoring • Monitoring nitrate reduction through source water blending • Finished drinking water product monitoring • Distribution system monitoring • Ion exchange/reverse osmosis removal efficiency monitoring • Nitrification/denitrification process efficiency monitoring • Surface water monitoring for contamination events and locating source pollution • Nitrogen removal process monitoring • and more..... “ The solutions offered by Real Tech combine outstanding performance and rock-solid reliability for even our most demanding applications. Real Tech delivers.” Dr. Peter Gallant Vice-President, ENDETEC Sensor Group | Veolia Water Solutions & Technologies REALTECHWATER.COM REALTECHWATER.COM Features and Benefits • Continuous online nitrate measurement • Easy to install and simple to operate • Proven UV absorption measurement principle • Practical and affordable monitoring system • Reagentless operation • Low operating cost with long life lamp • Reliable Split-Sense Pro technology • Various measurement ranges (mg/L) Simple. Accurate. Affordable. Real Tech’s Nitrate sensor uses ultraviolet (UV) and visible (VIS) absorbance technology to simply and accurately measure nitrates in real-time without the need for reagents or complex analytical methods. Low maintenance. Stable output. Real Tech’s innovative Split-Sense Pro technology uses a method of moving the sample from a test position to a reference position, allowing for continuous compensation of lamp and sensor drift. This practical method allows for long term stability in measurements, avoiding the need for frequent calibration. Full Control Operation and control of the Real Nitrate sensor is simple with Real Tech’s “plug and play” controllers. A single sensor or multiple sensors can be connected to one controller, bringing all data to one central location for quick and simple analysis. Access and Support With Real Tech’s optional remote monitoring capabilities, real-time data can be accessed anywhere, anytime allowing our clients to take control immediately. Additionally, this feature allows Real Tech to provide remote support for sensors giving our clients peace of mind and confidence in their data. Optional Automatic Chemical Cleaning The optional Real Clean systems are the ideal choice to keep maintenance to a minimum and performance at its best. The system can be programmed to meet the cleaning demands of each site, with the ability to recycle 90% of the chemical cleaning fluid - further reducing maintenance. UV Absorbance Measurement Principle Nitrate ions have a natural absorbance peak in the 200-220 nm wavelength range in the UV spectrum. As the concentration of nitrates in water increase, the absorbance of light in this distinct wavelength range will also increase. Common interferences with nitrate measurement at 220 nm, such as organic compounds, nitrite, iron (II), and turbidity or suspended solids are compensated for by measuring absorbance at additional reference wavelengths in the UV-VIS spectrum where the interfering compounds absorb, but nitrates do not. This multiple wavelength measurement approach ensures a high degree of accuracy. TAKE CONTROL, KNOW WHAT’S IN YOUR WATER REALTECHWATER.COM REALTECHWATER.COM Table 1: Models and Measurement Range Model Path Length NO3-N (mg/L) NO3 (mg/L) GL2010.Nitrate 1 mm 0-80 0-320 GL2020.Nitrate 2 mm 0-40 0-160 GL2040.Nitrate 4 mm 0-20 0-80 GL2080.Nitrate 8 mm 0-10 0-40 GL3500.Nitrate 50 mm 0-1.3 0-6 GL4000.Nitrate 250 mm 0-0.2 0-1 Table 2: Technical Specifications Characteristic Units Sampling Time Technical Data mg/L 10 seconds to 1 minute (depending on application) Calibration In-situ zeroing to DI water / Nitrate standards for NO3 calibration Cleaning In-situ chemical cleaning or optional automatic chemical cleaning Self-Diagnostics Alarms Humidity Control Detection and diagnosis of internal system fault Dry contact terminals allow for operator configurable alarms for: high and low set points, low lamp output, leak detected, system fault, etc. Humidity sensor with large plug-in regenerating desiccant system Wavelengths Up to 40 wavelengths between 200-750 nm Light Source Xenon Flash Lamp Lamp Life Dimensions 2-5 years 16”H x 20”W x 8”D Enclosure 1P66, NEMA 4, wall mountable Flow Rate 300-1000 mL/min Pressure Rating Fluid Connections Storage Temp. Operating Temp. Weight Warranty Technology Options 20 PSI 1/4” OD tube push-in fittings -20 to 60°C (-4 to 140°F) 0 to 45°C (32 to 113°F) 44 lbs 2-year limited warranty (Extended care packages available) Split-Sense Pro Dual Feed, Real Clean, Pump Clean, Seawater Upgrade, High Temperature Upgrade, etc. *Additional models and spec options available, contact Real Tech for more information. 1150 Champlain Court, Whitby ON L1N 6K9 Canada T 905.665.6888 TF 1.877.779.2888 F 905.665.7025 E [email protected] www.realtechwater.com