AUTOMATIC URINALS GW12..Z GW12..X GW 121 - GOLEM Water saving High hygiene Contactless control Simplier adjusted by magnet Antivandal design GW 122 - APOLLO PROPERTIES reacts only on usage of urinal (evaluets changes of temperature inside of urinal) does not react to standing or passing people flush time is adjustable in the parameter of 2 - 20 seconds thanks to permanen magnet Operating data GW 12..Z Power supply Power input GW 123 - LIVO Flushing time Working pressure Input of water Ooutlet water drain GW 12..X AC 20 V 4,2 VA DC 6V (battery) pulse operation durability cca 2 years 2 ÷ 20 sekund 0,1 ÷ 1 MPa inside screw G1/2" armature with seal f50 mm (novodur) Recommended accessories: GW 091Z - source AC 20 V for supplying max. 3 pieces of urinals together GW 092Z - source AC 20 V for supplying max. 5 pieces of urinals together CRP 2 - lithium 6 V Battery Guliwer electronics, s.r.o., Dukelských hrdinù 1011, 563 01 Lanškroun, Czech Republic Tel./fax: +420 465 461 531 Mobil: +420 603 162 962; +420 603 843 695; e-mail: [email protected]; http: //www.guliwer.cz Scheme of wiring and instalation: for GOLEM assembly holes / wall plug D14 240 power supply 20VAC / CYKY 2x0,75 water inlet G1/2 downpipe 1 - water input 2 - corner valve with filtration netting 3 - connecting hose 4 - electromagnetic valve 5 - outflow with seal 6 - electronics with sensor 7 - el. supply for electronics 8 - ceramic urinal 9 - self-priming trap 10 - waste tube Recommendation for installation: - instalation of waterinstalation and electroinstalation must agree with prewritten norms and they can be done only by skilled persons - before joining the piping, it is recommended to was input of water from dirt and deposits (it wil prevent possible damage of electromagnetic valve) - corner valve with filtration install onto input of water and connect up the hose with electromagnetic valve (see pict. 1) - connectors from power source connect to the electromagnetic valve and on terminal unit will be connected to the supply voltage - attachment of urinal, input and outpput of water ( the pipe must have ø 50 mm) and input of electric supply do according to picture 2 Examples of ordering: 222 GW 121Z - automatic urinal with power source AC 20 V, electromagnetic valve input and output G 1/2" GW 121Z-M - automatic urinal with power source AC 20 V, demountable electromagnetic valve input and output G 1/2" GW 121X - automatic urinal with power source from 6 V battery Guliwer electronics, s.r.o., Dukelských hrdinù 1011, 563 01 Lanškroun, Czech Republic Tel./fax: +420 465 461 531 Mobil: +420 603 162 962; +420 603 843 695; e-mail: [email protected]; http: //www.guliwer.cz