Terracon Final Phase I ESA Report
Transcription
Terracon Final Phase I ESA Report
Phase I Environmental Site Assessment New Cheyenne Public Safety Center West 17th and Pioneer Ave Cheyenne, Laramie County, WY April 30, 2013 Terracon Project No. 24137705 Prepared for: City of Cheyenne Cheyenne, Wyoming Prepared by: Terracon Consultants, Inc. Cheyenne, Wyoming TABLE OF CONTENTS Page No. EXECUTIVE SUMMARY ............................................................................................................................... i Findings ............................................................................................................................................. i Conclusions .......................................................................................................................................ii Recommendations ........................................................................................................................... iii 1.0 INTRODUCTION.............................................................................................................................. 1 1.1 Site Description ................................................................................................................... 1 1.2 Scope of Services ............................................................................................................... 1 1.3 Standard of Care ................................................................................................................. 2 1.4 Additional Scope Limitations, ASTM Deviations and Significant Data Gaps ...................... 2 1.5 Reliance .............................................................................................................................. 3 1.6 Client Provided Information ................................................................................................. 4 2.0 PHYSICAL SETTING ...................................................................................................................... 4 3.0 HISTORICAL USE INFORMATION ................................................................................................ 5 3.1 Historical Topographic Maps .............................................................................................. 5 3.2 Historical Aerial Photographs .............................................................................................. 6 3.3 Historical City Directories .................................................................................................... 7 3.4 Historical Fire Insurance Maps ......................................................................................... 14 3.5 Site Ownership .................................................................................................................. 17 3.6 Title Search ....................................................................................................................... 17 3.7 Environmental Liens.......................................................................................................... 17 3.8 Historical and Site Interviews ............................................................................................ 17 3.9 Prior Report Review .......................................................................................................... 20 3.10 Historical Use Information Summary ................................................................................ 20 4.0 RECORDS REVIEW ...................................................................................................................... 21 4.1 Federal and State/Tribal Databases ................................................................................. 21 4.2 Local Agency Inquiries ...................................................................................................... 31 4.2.1 Fire Department ................................................................................................... 31 4.2.2 Local/Regional Pollution Control Agency ............................................................. 31 4.3 Records Review Summary ............................................................................................... 31 5.0 SITE RECONNAISSANCE ............................................................................................................ 31 5.1 General Site Information ................................................................................................... 31 5.2 Overview of Current Site Occupants and Operations ....................................................... 32 5.3 Site Observations .............................................................................................................. 32 5.4 Site Reconnaissance Summary ........................................................................................ 36 6.0 ADJOINING PROPERTY RECONNAISSANCE ........................................................................... 36 7.0 ADDITIONAL SERVICES .............................................................................................................. 36 8.0 DECLARATION ............................................................................................................................. 37 TABLE OF CONTENTS (continued) APPENDICES APPENDIX A Exhibit 1 - Topographic Map, Exhibit 2 – Site Diagram, Exhibit 3 – Building Diagram-First Floor, Exhibit 4 – Building Diagram-Basement APPENDIX B Description of Terms and Acronyms APPENDIX C Historical Documentation and User Questionnaire APPENDIX D Environmental Database Information APPENDIX E Site Photographs APPENDIX F Credentials Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 EXECUTIVE SUMMARY This Phase I Environmental Site Assessment (ESA) was performed in accordance with Terracon Proposal No. 2413E009 dated March 11, 2013, and was conducted consistent with the procedures included in ASTM E 1527-05, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process. The ESA was conducted under the supervision or responsible charge of Clay Muirhead, P.E., Environmental Professional. Carrie Harns performed the site reconnaissance on April 30, 2013. Findings A cursory summary of findings is provided below. It should be recognized that details were not included or fully developed in this section, and the report must be read in its entirety for a comprehensive understanding of the items contained herein. Site Description and Use The site includes one building (Dinneen Building) currently used as offices and for storage. The building includes a basement of approximately 24,000 square feet, a first floor of approximately 30,000 square feet, and a roof top parking deck of approximately 15,000 square feet on the west portion of the building. The site also includes two parking lots. The west parking lot is used for paid monthly parking and the east parking lot is rented to Sidles for their parking needs. The northwest portion of the first floor of the building includes four office suites that are occupied by Home Instead Senior Care (Suite A), a real estate office (Suite B), Domonkos Law Office (Suite C), and Wyoming Senior Citizens Inc. (Suite D). Historical Information Based on a review of the historical information, the site was developed prior to 1883. Previous uses of the site included blacksmithing; painting; laundry and dry cleaning; creamery; filling station; vulcanizing; and auto sales, service, repair, and painting. The east portion of the existing building on site was thought to have been constructed between 1915 and 1920 and was used for automobile sales, service, repair, and painting. The west portion of the existing building on-site was constructed in approximately 1961 and was used for automobile sales, service, repair and painting. The site was purchased by Dinneen in 1989 and the building was renovated by Dinneen in 1991. Dinneen used the site for automobile sales, service, repair and painting. The adjoining properties to the north, east, south and west were developed prior to 1883. Previous uses of the adjoining properties to the north included painting; machine repair; steam laundry; a filling station; and auto sales, service, and repair. Previous uses of the adjoining properties to the east included Chinese laundry; photography; tire sales and service; a filling station; automobile service and repair; and machine repair. Previous uses of the adjoining properties to the south included Chinese laundry; painting; blacksmithing; auto repair and machine repair. Previous uses of the adjoining properties to the west included Chinese laundry; Responsive ■ Resourceful ■ Reliable i Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 blacksmithing; auto sales, service and repair; machine repair; and dry cleaning. The above referenced uses of the site and adjoining properties constitute a REC to the site. Records Review Selected federal and state environmental regulatory databases as well as responses from state and local regulatory agencies were reviewed. Several facilities were identified in the regulatory databases. Based on distance, environmental setting and/or facility characteristics, the northeast corner of the site, the northwest adjoining property and three topographically upgradient facilities constitute RECs to the site. Site Reconnaissance Based on site reconnaissance, RECs were identified associated with the current site operations including a former underground hydraulic hoist, oil/water separators, and unidentified floor cuts and penetrations. Adjoining Properties Indications of RECs were not visually observed with the current use of the adjoining properties. Additional Services Per the agreed scope of services specified in the proposal, the following additional services were conducted: Asbestos Survey. Please refer to the IHI Environmental Asbestos-Containing Material Field Survey Report (IHI Project No. AM137527) for the findings of these assessments. Conclusions We have performed a Phase I ESA consistent with the procedures included in ASTM Practice E 1527-05 at 410 W 17th, 416 W 17th, 405 W 18th, 1704 Pioneer, and the associated parking lots, Cheyenne, Laramie County, Wyoming, the site. Recognized environmental conditions were identified in connection with the site and include the following: Past uses of the site and adjoining properties; Interviews identifying the northwest adjoining property as a contaminated site; Regulatory database listings that include the site and three topographically upgradient facilities; and Observations of a former underground hydraulic hoist, oil/water separators and unidentified floor cuts and penetrations in the building. Responsive ■ Resourceful ■ Reliable ii Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Recommendations Based on the scope of services, limitations, and findings of this assessment, Terracon recommends a limited site investigation to obtain additional information regarding the potential impact to the site from the RECs identified herein. Responsive ■ Resourceful ■ Reliable iii PHASE I ENVIRONMENTAL SITE ASSESSMENT NEW CHEYENNE PUBLIC SAFETY CENTER WEST 17TH AND PIONEER AVE CHEYENNE, LARAMIE COUNTY, WYOMING Terracon Project No. 24137705 April 30, 2013 1.0 INTRODUCTION 1.1 Site Description Site Name New Cheyenne Public Safety Center Site Location/Address 410 W 17th, 416 W 17th, 405 W 18th, and 1704 Pioneer, Cheyenne, Laramie County, Wyoming Land Area Approximately 1.31 acres Site Improvements The north portion of the site includes a building with an approximately 30,000 square foot first floor, an approximately 24,000 square foot basement and approximately 15,000 square feet of parking area on the roof of the west portion of the building. The remainder of the site is two paved parking lots on the south end of the site. The building was renovated in 1991. The storm drain system in the alley running through the middle of the site was improved in 1991. The overhead electrical lines were also buried in the alley in 1991. The site location is depicted on Exhibit 1 of Appendix A, which was reproduced from a portion of the USGS 7.5-minute series topographic map. A Site Diagram of the site and adjoining properties is included as Exhibit 2 of Appendix A. Site Building Diagrams are included as Exhibits 3 and 4 of Appendix A. Acronyms and terms used in this report are described in Appendix B. 1.2 Scope of Services This Phase I ESA was performed in accordance with Terracon Proposal No. 2413E009 dated March 11, 2013, and was conducted consistent with the procedures included in ASTM E 152705, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process. The purpose of this ESA was to assist the client in developing information to identify Recognized Environmental Conditions (RECs) in connection with the site as reflected by the scope of this report. This purpose was undertaken through user-provided information, a regulatory database review, historical and physical records review, interviews, including local government inquiries, as applicable, user-provided information, and a visual noninvasive Responsive ■ Resourceful ■ Reliable 1 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 reconnaissance of the site and adjoining properties. Limitations, ASTM deviations, and significant data gaps (if identified) are noted in the applicable sections of the report. As requested by the client, the following additional services were performed: 1.3 Asbestos Survey Standard of Care This ESA was performed in accordance with generally accepted practices of this profession, undertaken in similar studies at the same time and in the same geographical area. We have endeavored to meet this standard of care, but may be limited by conditions encountered during performance, a client-driven scope of work, or inability to review information not received by the report date. Where appropriate, these limitations are discussed in the text of the report, and an evaluation of their significance with respect to our findings has been conducted. Phase I ESAs, such as the one performed at this site, are of limited scope, are noninvasive, and cannot eliminate the potential that hazardous, toxic, or petroleum substances are present or have been released at the site beyond what is identified by the limited scope of this ESA. In conducting the limited scope of services described herein, certain sources of information and public records were not reviewed. It should be recognized that environmental concerns may be documented in public records that were not reviewed. No ESA can wholly eliminate uncertainty regarding the potential for RECs in connection with a property. Performance of this practice is intended to reduce, but not eliminate, uncertainty regarding the potential for RECs. No warranties, express or implied, are intended or made. The limitations herein must be considered when the user of this report formulates opinions as to risks associated with the site or otherwise uses the report for any other purpose. These risks may be further evaluated – but not eliminated – through additional research or assessment. We will, upon request, advise you of additional research or assessment options that may be available and associated costs. 1.4 Additional Scope Limitations, ASTM Deviations and Significant Data Gaps Based upon the agreed-on scope of services, this ESA did not include subsurface or other invasive assessments, business environmental risk evaluations, or other services not particularly identified and discussed herein, including an evaluation of vapor encroachment conditions. Credentials of the company (Statement of Qualifications) have not been included in this report but are available upon request. Pertinent documents are referred to in the text of this report, and a separate reference section has not been included. Reasonable attempts were made to obtain information within the scope and time constraints set forth by the client; however, in some instances, information requested is not, or was not, received by the issuance date of the report. Information obtained for this ESA was received from several sources that we believe to be reliable; nonetheless, the authenticity or reliability of these sources cannot and is not warranted hereunder. This ESA was further limited by the following: Responsive ■ Resourceful ■ Reliable 2 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Historic information was not reasonably ascertainable back to the date the site was developed, which is believed to be prior to 1883. Uses of the site were described as far back as 1883. Office B-1 was locked and inaccessible during the site reconnaissance. An evaluation of the significance of these limitations and missing information with respect to our findings has been conducted, and where appropriate, significant data gaps are identified and discussed in the text of the report. However, it should be recognized that an evaluation of significant data gaps is based on the information available at the time of report issuance, and an evaluation of information received after the report issuance date may result in an alteration of our conclusions, recommendations, or opinions. We have no obligation to provide information obtained or discovered by us after the issuance date of the report, or to perform any additional services, regardless of whether the information would affect any conclusions, recommendations, or opinions in the report. This disclaimer specifically applies to any information that has not been provided by the client. This report represents our service to you as of the report date and constitutes our final document; its text may not be altered after final issuance. Findings in this report are based upon the site‟s current utilization, information derived from the most recent reconnaissance and from other activities described herein; such information is subject to change. Certain indicators of the presence of hazardous substances or petroleum products may have been latent, inaccessible, unobservable, or not present during the most recent reconnaissance and may subsequently become observable (such as after site renovation or development). Further, these services are not to be construed as legal interpretation or advice. 1.5 Reliance This ESA report is prepared for the exclusive use and reliance of City of Cheyenne. Use or reliance by any other party is prohibited without the written authorization of City of Cheyenne and Terracon Consultants, Inc. (Terracon). Reliance on the ESA by the client and all authorized parties will be subject to the terms, conditions and limitations stated in the proposal, ESA report, and Terracon‟s Agreement for Services. The limitation of liability defined in the Agreement for Services is the aggregate limit of Terracon‟s liability to the client and all relying parties. Continued viability of this report is subject to ASTM E 1527-05 Sections 4.6 and 4.8. If the ESA will be used by a different user (third party) than the user for whom the ESA was originally prepared, the third party must also satisfy the user‟s responsibilities in Section 6 of ASTM E 1527-05. Responsive ■ Resourceful ■ Reliable 3 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 1.6 Client Provided Information Prior to the site visit, Lt. Mark Munari, client‟s representative, was asked to provide the following user questionnaire information as described in ASTM E1527-05 Section 6. Client Questionnaire Responses Client Questionnaire Item Client’s Response Client Did Not Respond Yes No Aware of any Environmental Cleanup Liens against the site. X Actual Knowledge of Environmental Liens or Activity Use Limitations (AULs) that may encumber the site. X Aware of any Specialized Knowledge or Experience related to the site or nearby properties. X Actual Knowledge of a Significantly Lower Purchase Price because of hazardous substances or petroleum products. X Commonly Known or Reasonably Ascertainable Information that is material to a release in connection with the site. X Obvious Indicators of Contamination at the site. X Terracon‟s consideration of the client provided information did not identify RECs. A copy of the questionnaire is included in Appendix C. 2.0 PHYSICAL SETTING Physical Setting Information Source Topography (Refer to Appendix A for an excerpt of the Topographic Map) Site Elevation Surface Runoff/ Topographic Gradient Closest Water Soil Type Description Surface Approximately 6068 feet (NGVD) Relatively flat area with general gradient towards the southeast based on site observations Crow Creek, approximately 2500 feet to the east of the site. Soil Characteristics land-Poposhia-Trimad complex, Urban 3-15% slopes Poposhia soil is very deep, well drained, moderately permeable and formed in silty alluvium. The surface layer is brown silt loam, about 6" thick and the Responsive ■ Resourceful ■ Reliable USGS Topographic Map, Cheyenne North, Wyoming Quadrangle, 1994 Laramie County, WY USDA-NRCS Web Soil Survey issued February 22, 2007 4 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Physical Setting Information Source underlying material to a depth of 60"+ is very pale brown silt loam. Trimad soil is very deep, well drained, moderately permeable and formed in very gravelly loamy alluvium. The upper part of the surface layer is dark brown loam about 3" thick and the lower 7" is brown gravelly loam. The upper 24" of the subsoil is very pale brown very gravelly sandy loam. Geology/Hydrogeology Formation Deposits of Fox Farm Terrace Description Consists generally of gravel and gravelly sand overlain by 2-5 feet of silt and sand. Mostly subrounded and subangular pebbles and small cobbles; some large cobbles and a few small boulders may be present. Thickness is approximately 25 feet. M.E. Cooley & M.A. Crist, Geohydrology of the High Plains Aquifer System, Cheyenne Urban Area, Wyoming, USGS WRIR 92-4047. M.E. Cooley & M.A. Crist, Geohydrology of the High Plains Aquifer System, Cheyenne Urban Area, Wyoming, USGS WRIR 92-4047. Estimated Depth to First Occurrence of Groundwater Approximately 13 feet *Hydrogeologic Gradient Not known - may be inferred to be parallel to topographic gradient (primarily to the southeast). * The groundwater flow direction and the depth to shallow, unconfined groundwater, if present, would likely vary depending upon seasonal variations in rainfall and other hydrogeological features. Without the benefit of on-site groundwater monitoring wells surveyed to a datum, groundwater depth and flow direction beneath the site cannot be directly ascertained. 3.0 HISTORICAL USE INFORMATION Terracon reviewed the following historical sources for indications of RECs. A summary of the historical review is included at the end of the Historical Use Information section. Copies of selected historical documents are included in Appendix C. 3.1 Historical Topographic Maps Readily available historical USGS topographic maps were not reviewed to evaluate land development in connection with the site because the site is located in a densely developed part of the city. Responsive ■ Resourceful ■ Reliable 5 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 3.2 Historical Aerial Photographs Selected historical aerial photographs provided by Historic Information Gatherers (HIG) were reviewed at approximately 10 to 15 year intervals, if readily available, to obtain information concerning the history of development on and near the site. Evaluation of these aerials may be limited by a photo‟s quality and scale. Selected photographs are summarized below. HIG, photo ID# 132599, 1947, 1” = 800‟ HIG, photo ID# 132599, 1960, 1” = 500‟ HIG, photo ID# 132599, 1990, 1” = 800‟ HIG, photo ID# 132599, 1994, 1” = 500‟ HIG, photo ID# 132599, 2006, 1” = 500‟ HIG, photo ID# 132599, 2012, 1” = 500‟ Historical Aerial Photographs Direction Description Site Due to the scale of the photographs, the description of the “site” will include the entire th th block from W 17 north to W 18 and Thomes Ave east to Pioneer Ave. The block appears to include several buildings (1947, 1960). Fewer buildings are seen and there appears to be a parking lot (1990). There appears to be two paved parking lots and the remainder of the block is buildings (1994). The block appears unchanged (2006, 2012). North Due to the scale of the photographs, the description of the north adjoining properties th th will include the three blocks from W 18 north to W 19 and O‟Neil Ave east to Carey Ave. Each block includes several buildings (1947). The blocks appear unchanged (1960). There appear to be fewer buildings and more parking areas (1990). The blocks appear unchanged (1994). There appear to be several new and different buildings and paved parking areas (2006). The blocks appear unchanged (2012). East Due to the scale of the photographs, the description of the east adjoining properties th th will include the block from W 17 north to W 18 and from Pioneer Ave east to Carey Ave. The block includes several buildings (1947). The structure of the buildings appears to change over the years (1960, 1990, 1994, 2006, 2012). South Due to the scale of the photographs, the description of the south adjoining properties th th will include the three blocks from W 16 (Lincolnway) north to W 17 and from O‟Neil Ave east to Carey Ave. Each block includes several buildings (1947). The blocks appear unchanged (1960). The easternmost block appears to no longer include buildings (1990). The easternmost block appears to be a paved parking lot (1994). The easternmost block appears as one large structure (2006). There appear to be fewer buildings and more parking areas on the two westernmost blocks (2012). Responsive ■ Resourceful ■ Reliable 6 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Direction Description West Due to the scale of the photographs, the description of the west adjoining properties th th will include the block from W 17 north to W 18 and from O‟Neil Ave east to Thomes Ave. The block appears to include several buildings (1947, 1960). Two buildings are seen in the block, and the rest of the area appears to be cleared and portions paved (1990). The block includes two buildings and the remainder of the block appears to be paved parking areas (1994). The block appears unchanged (2006, 2012). 3.3 Historical City Directories The Cheyenne, WY city directories used in this study were made available through Laramie County Library (selected years reviewed: 1902 through 2010) and were reviewed at approximate ten-year intervals, if readily available. Since these references are copyright protected, reproductions are not provided in this report. Street listings for the site were not available prior to 1902. The current street addresses for the site were identified as 410 W 17th St, 416 W 17th St, 405 W 18th St, and 1704 Pioneer Ave. For the simplicity of the following table, the “site” listings will include all listings for the block from W 17th north to W 18th and from Thomes Ave east to Pioneer Ave (Eddy St); however if the address is an adjoining property, it will be indicated. Historical City Directories Direction Description 1902 – 1706 Eddy St, 1708 Eddy St, 1710 Eddy St, 1716 Eddy St: Residences; 1712 Eddy St (adjoining property): Durant Hose House, residences; 1718 Eddy St: th th Vacant. No listings for W 17 St, W 18 St, and Thomes St. th th th th 1913-14 – 402 W 17 St, 402 ½ W 17 St, 406 W 17 St, 408 W 17 St (adjoining th th th properties): Residences; 412 W 17 St, 412 ½ W 17 St, 418 W 17 St, 418 ½ W th th th th 17 St, 420 W 17 St, 422 W 17 St: Residences; 416 W 17 St: Sherman Hotel. th th 417 W 18 St: Residence; 421 W 18 St: Cheyenne Creamery Co. 1707 Thomes St, 1711 Thomes St: Residences. 1712 Eddy St: Fire Department (adjoining property). th Site th th 1924 – 400 W 17 St, 406 W 17 St: Residences (adjoining properties), 402 W 17 th St: California Fish Mkt (adjoining property); 404 W 17 St: Vacant (adjoining th th property); 408 W 17 St: Mandanis Bakery & Gro. (adjoining property); 412 W 17 th th th St: Corbet Ice Cream Co.; 416 W 17 St, 416 ½ W 17 St, 418 W 17 St: th th Residences; 420 W 17 St: Vacant; 422 W 17 St: Q & S Oil co., WW Motor Co. 413 th th th th W 18 St, 415 W 18 St, 417 W 18 St: Residences; 421 W 18 St: Cheyenne Creamery Co. 1707 Thomes St: Residence; 1709 Thomes St: Modern Method Beauty Shop; 1711 Thomes St: Cheyenne Radio Shop, The LB Price Mer Co. 1708 Pioneer Ave: Coliseum Billiards, Pioneer Stge & Fur Co; 1708 ½ Pioneer Ave: Coliseum Dance Hall; 1718 Pioneer Ave: Store Room; 1720 Pioneer Ave: Cheyenne Sheet Mtl Wks, Residence; 1722 Pioneer Ave: Cheyenne Filling Station. th th 1933-34 – 400 W 17 St: Wyo Automotive Co (adjoining property); 406 W 17 St: Responsive ■ Resourceful ■ Reliable 7 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Direction Description th Mac Marr‟s gro (adjoining property); 408 W 17 St: Matsuhima Takimatsu barber th th (adjoining property); 410 W 17 St: New Method Clnrs; 412 W 17 St: Corbett Ice th th Cream Co, residence; 416 W 17 St: Farris Market meats; 416 ½ W 17 St: Hazel th th Rooms; 418 W 17 St: Baker John A soft drinks; 418 ½ W 17 St: Residence; 422 W th th th 17 St: California Fish Market, residence. 413 W 18 St: Shuman Clnrs; 417 W 18 th St: Residences; 421 W 18 St: Vacant. 1707 Thomes Ave: Vacant; 1709 Thomes Ave: Denver Post Agency, Robbins Gilbert B bicycles; 1711 Thomes Ave: Wyo Poultry & Egg Co whol. 1704 Pioneer Ave: MacMarr Food Store, Chambers Ray meats; 1704 ½ Pioneer Ave: Coliseum Dance Hall; 1706 Pioneer Ave: Stop Shop Market gro; 1708 Pioneer Ave: Residence, Brunswick Cigar Store; 1710 Pioneer Ave: Vacant; 1712 Pioneer Ave: Residences, Capital Battery & Elec Co. (adjoining property); 1716 Pioneer Ave: Sanitary Home Lndry; 1720 Pioneer Ave: Roe Motor Co. th th th th 1945 – 400 W 17 St: United Auto Supply Stores (adjoining property); 404 W 17 St: th Fader‟s Gun Shop, residence (adjoining property); 406 W 17 St: Ed‟s Linoleum th th Shop (adjoining property); 406 ½ W 17 St: Vacant (adjoining property); 408 W 17 th St: Wahl‟s Cycle & Key Shop (adjoining property); 410 W 17 St: Dr Pepper Bottling th th Co, Squirt Bottling Co; 412 W 17 St: Cohen Benj Z meats; 414 W 17 St, 418 ½ W th th th 17 St: Residences; 418 W 17 St: Baker John A liquors; 420 W 17 St: Shamrock th th th Café; 422 W 17 St: California Fish Market. 413 W 18 St: Elite Clnrs; 417 W 18 St: th Residences; 423 W 18 St: United Service Org. 1707 Thomes Ave: West Side Shoe Shop, McCoy Jas E barber; 1709 Thomes Ave: Kashiwagi Sekichi billiards; 1711 Thomes Ave: Vacant, Manners-Roush Motors auto rprs. 1704 Pioneer Ave: Pioneer Billiards, Pioneer Studio photogs; 1704 ½ Pioneer Ave: Coliseum Apartments; 1706 Pioneer Ave: Fitch F W electric contr; 1708 Pioneer Ave: Casper Supply Co Inc; 1710 Pioneer Ave: Home Servicing Co furn reprs; 1712 Pioneer Ave: Wyoming Automotive Co whol (adjoining property); 1718 Pioneer Ave: Sanitary Home Laundry; 1720 Pioneer Ave: Taylor Pontiac Co. 1955 – 400 W 17 St: United Auto Supply Stores (adjoining property); 406 W 17 St: th Frontier Flooring Co (adjoining property); 408 W 17 St: Wahl‟s Cycle & Key Shop th th (adjoining property); 408 ½ W 17 St: Vacant (adjoining property); 410 W 17 St: Dr. th th Pepper Bottling Co; 412 W 17 St: Cheevers Automotive Mach Shop Inc; 414 W 17 th th St: Vacant; 416 W 17 St: Baker John A (office), Baker‟s Place; 418 ½ W 17 St: th th Residence; 420 W 17 St: Wheel of Fortune Café; 422 W 17 St: California Fish th Market. 423 W 18 St: Montgomery Ward (whse). 1705 Thomes Ave: Veterans Barber Shop; 1707 Thomes Ave, 1711 Thomes Ave: Vacant; 1709 Thomes Ave: Hashimoto Itsuki billiards. 1704 Pioneer Ave: Pioneer Billiards; 1704 ½ Pioneer Billiards: Coliseum Apartments; 1706 Pioneer Ave: Local Finance Co Inc; 1708 Pioneer Ave: Casper Supply Co Inc auto parts; 1712 Pioneer Ave: Wyoming Automotive Co whol; 1716-20 Pioneer Ave: Taylor Building; 1720 Pioneer Ave: Taylor Pontiac Co. th 1965 – 400 W 17 St: Sidles Automotive Supply Store (adjoining property); 406 W th th 17 St: Herrin John W acct (adjoining property); 408 W 17 St: Wahl‟s Cycle & Key th Shop (adjoining property); 408 ½ W 17 St: Vacant (adjoining property); 410-12 W th th 17 St: Cheever‟s Automotive Machine Shop Inc; 418 W 17 St: Klipstein Sales Lot Responsive ■ Resourceful ■ Reliable 8 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Direction Description auto. 1710 Pioneer Ave: Casper Supply Co. Inc auto parts; 1716-20 Pioneer Ave: th Taylor Building; 1720 Pioneer Ave: Taylor Pontiac-Buick Co. No listings for W 18 St and Thomes Ave. th 1975 – 400 W 17 St: Sidles company automotive parts (adjoining property); 406 W th th 17 St: Sidles Co Stge (adjoining property); 408 W 17 St: Wahl‟s Schwinn Cyclery th bicycle sls & serv (adjoining property); 410 W 17 St: Cheever‟s Automotive Machine th Shop Inc; 416 W 17 St: No Return. 1704 Pioneer Ave, 1706 Pioneer Ave: No Return; 1710 Pioneer Ave: West Side Community Center; 1712 Pioneer Ave: No Return (adjoining property); 1716-20 Pioneer Ave: Taylor Building; 1720 Pioneer th Ave: Taylor Pontiac-Buick Jeep Co. No listings for W 18 St and Thomes Ave. th th 1985 – 400 W 17 St: Sidles Co automotive parts (adjoining property); 406 W 17 th St: Sidles co automotive pnt (adjoining property); 408 W 17 St: Wahl‟s Schwinn th Cyclery bicycle sls & serv (adjoining property); 410 W 17 St: Royal Glass; 416 W th 17 St: Residence. 1706 Pioneer Ave, 1710 Pioneer Ave: Vacant; 1712 Pioneer Ave: Vacant (adjoining property); 1720 Pioneer Ave: Mecham Pontiac Buick Jeep th Co. No listings for W 18 St and Thomes Ave. th 1995 – 400 W 17 St: Sidles Co automotive parts (adjoining property); 406 Sidles Co th (Auto Paint Sup) (adjoining property); 408 W 17 St: Wahl‟s Cyclery bicycle sls & th th serv (adjoining property); 420 W 17 St: Dinneen Pontiac Buick auto dlrs. 405 W 18 St: Dinneen Pontiac Buick parts dept; 413 Wyoming Senior Citizens Inc; Senior th Companion Program, Wyoming Older Workers Program govt agency; 419 W 18 St: Wyoming Automobile Dealers Assoc. 1723 Thomes Ave: Edward Jones brokerage firm, BHJ Inc insurance. 1710 Pioneer Ave: Parking Lot; 1712 Pioneer Ave: Ross & Ross lwyrs, Ross Vincent A atty, Ross Anthony F atty, Santini George atty (adjoining property). th 2005 – 406 W 17 St: Sidles Co Automotive Parts auto body shop equip/supl th (adjoining property); 408 W 17 St: Advanced Cash SVC loans (adjoining property); th th 420 W 17 St: Dinneen Detail Shop auto detail & clean-up serv. 413 W 18 St: WY Senior Citizens Inc senior citizens serv; ARC Affordable Residential housing authorities. 1723 Thomes Ave: No current listing, Wyoming Automobile Dealer Assn associations. 1712 Pioneer Ave: Sonic Drive-In restaurants (adjoining property). th 2010 – 406 W 17 St: Sidles Co Automotive Paint auto parts & supl- retail-new th (adjoining property); 408 W 17 St: Advanced Cash SVC payday loans (adjoining th property). 413 W 18 St: Wyoming Senior Citizens Inc senior citizens serv; 419 W th 18 St: Oswald Peter W. 1723 Thomes Ave: Prudential Financial insurance, Home Instead Senior Care senior citizens serv. 1712 Pioneer Ave: Clinical Prevention wellness programs, Corps Today Inc consultants- business, Graham Norris Jr Atty at Law attorneys, Hibbler Bill G attorneys (adjoining property). th North th th th 1902 – (North) 406 W 18 St: Vacant; 410 W 18 St, 412 W 18 St, 416 W 18 St: th th th Residences. (Northwest) 500 W 18 St: H B Emigh Store; 502 W 18 St, 510 W 18 St: Residences. No listings northeast. th th th th 1913-14 – (North) 406 W 18 St, 410 W 18 St, 414 W 18 St, 416 W 18 St: th Residences; 422 W 18 St: African M E Church. 1808 Eddy St: Residence. th th th (Northwest) 502 W 18 St: Socialist Headquarters; 504 W 18 St, 510 W 18 St: Responsive ■ Resourceful ■ Reliable 9 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Direction Description Residences. 1804 Thomes St, 1810 Thomes St: Residences. No listings northeast. th th th 1924 – (North) 410 W 18 St, 412 W 18 St: Residences; 414 W 18 St: Residence, th Western Poultry House; 422 W 18 St: African M E Church. 1808 Pioneer Ave: City th th Auto Trimming Co. (Northwest) 500 W 18 St, 502 W 18 St: Residences; 504 W th th 18 St: Vacant; 506-518 W 18 St: Cheyenne Steam Lndry & Clng Co. 1804 Thomes St, 1810 Thomes St: Residences. No listings northeast. th th 1933-34 – (North) 408 W 18 St: Vizina Arth Motor Co; 414 W 18 St: Vacant; 422 th W 18 St: African M E Ch. 1810 Pioneer Ave: Atlas Tire Shop, Standard Oil Co. th th (Northwest) 500 W 18 St: Faulk Edw H gro; 502 W 18 St: Price L B Merc Co; 504 th th W 18 St: Texas Café; 508 W 18 St: Cheyenne Steam Laundry. No listings northeast. th th th 1945 – (North) 406 W 18 St, 410 W 18 St: Residences; 408 W 18 St: Post Office th th Garage, Capitol Battery & Electric Co; 412 W 18 St: Wood Lunch Room; 418 W 18 th St: Motor Sales Co used cars; 422 W 18 St: African M E Church. 1800 Pioneer Ave: Fort Warren Bus Terminal; 1810 Pioneer Ave: Standard Oil Co of Ind (office), War Manpower Comn US Emp Serv, US Civil Service Comn; State Employment Security th th Comn. (Northwest) 500 W 18 St: American Cleaners & Tailors; 504 W 18 St: th Texas Café, residence; 508 W 18 St: Cheyenne Steam Lndry; 1810 Thomes Ave: Residence. No listings northeast. th th 1955 – (Northeast) 324 W 18 St: General Credit Corp. (North) 406 W 18 St, 410 W th th th 18 St: Residences; 408 W 18 St: Pioneer Motor Co; 412 W 18 St: Blu-Inn Café; th th 418 W 18 St: Pioneer Motor Co used cars; 422 W 18 St: Allen Chapel African M E Church. 1804 Pioneer Ave: Jack‟s Standard Serv gas sta; 1810 Pioneer Ave: Commercial Credit Corp, Standard Oil Co of Ind (ofc), Calver Fire Ins Co. th th (Northwest) 500 W 18 St: American Clns & Tailors; 504 W 18 St: Veteran‟s Café, th residence; 508 W 18 St: Cheyenne Steam Lndry & Dry Cleaners. 1810 Thomes Ave: Residence. th th th th 1965 – (North) 406 W 18 St, 408 W 18 St, 410 W 18 St: Vacant; 422 W 18 St: Allen Chapel AME Church. 1800 Pioneer Ave: Central Credit Co; 1808 Pioneer Ave: State Farm Insurance; 1810 Pioneer Ave: Miller Suyematsu Crowley & Duncan lwyrs, State Div of Vocational Rehabilitation Center, State Dept of Educ, Orthman th th Allen F acct. (Northwest) 500 W 18 St, 504 W 18 St: Vacant. 1810 Thomes Ave: Residence. No listings northeast. th 1975 – (North) 422 W 18 St: Allen Chapel AME Church. 1800 Pioneer Ave: Fidelity Finance Co loans. 1810 Pioneer Ave: Laramie County Legal Service Inc lwyrs. No listings northeast or northwest. 1985 – (Northeast) 1803 Pioneer Ave: First Wyoming National Bank (North) 408 W th 18 St: Vacant. 1800 Pioneer Ave: Vacant, 1810 Pioneer Ave: Barrington Realty Co, US Veterans Administration. No listings northwest. th 1995 – (North) 408 W 18 St: Vacant. 1810 Pioneer Ave: First America Title Guaranty Agency of Cheyenne. (Northeast) 1803 Pioneer Ave: Key Bank of Wyoming. 2005 – (Northeast) 314 W 18 Responsive ■ Resourceful ■ Reliable th St: McGee Hearne & Piaz accountants, Micale 10 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Direction Description Management fuel mgmt. (North) 1810 Pioneer Ave: Health First physicians & th surgeons, individual. (Northwest): 500 W 18 St: First State Bancshares holding companies, Security First Bank banks, MKK Consulting Engineers. th 2010 – (Northeast) 314 W 18 St: McGee Hearne & Piaz LLC accountants, Micale Management fuel mgmt. (North) 1810 Pioneer Ave: Nursing Board government th offices-state. (Northwest): 500 W 18 St: MKK Consulting Engineers, Main Security First Bank banks. 1902 – 1701-05 Eddy St: Dinneen Bros; 1713 Eddy St, 1715 Eddy St, 1717 Eddy St: th th Residences. 320 W 17 St: Residence; 322 W 17 St: Dinneen Bros. No listing W th 18 St. 1913-14 – 1711 Eddy St: Cheyenne Rubber Wks; 1713 Eddy St, 1713 ½ Eddy St, th th 1715 Eddy St: Residences. 320 W 17 St: Residence; 322 W 17 St: James Bros. th No listing W 18 St. th 1924 – 321 W 18 St: Aero Oil Products Co. 1711 Pioneer Ave: Cheyenne Rubber th Tire Wks; 1715 Pioneer Ave, 1719 Pioneer Ave: Residences. 320 W 17 St: Western th States Tlg Co.; 322 W 17 St: Wyoming Hdw Co. th 1933-34 – 321 W 18 St: Smith Frank Auto Parts. 1709 Pioneer Ave: Smith Bros th Glass & Paint Co; 1717 Pioneer Ave: Cheyenne Coca-Cola Bottling Co. 320 W 17 th St: Bruce Wm L locksmith, Meanea F A Harness Shop; 320 ½ W 17 St: Davis Blk th furn rms; 322 W 17 St: Wyoming Hdw Co. th th 1945 – 321 W 18 St: US Railroad Retirement Bd; 325 W 18 St: Wyo Abstract & Tile Co. 1715 Pioneer Ave: Wyoming Aircraft School (br); 1719 Pioneer Ave: Smith th Frank auto serv; 1721 Pioneer Ave: Vacant. 320 W 17 St: Safeway Stores Inc gro th and meats; 320 ½ W 17 St: Davis Apts. th East 1955 – 325 W 18 St: General. 1709 Pioneer Ave: Wyoming State Employment Serv, Employment Security Commission of Wyoming; 1715 Pioneer Ave: Pioneer th th Parking Garage. 320 ½ W 17 St: Davis Block Apartments; 322 W 17 St: Electrical Center Store No 2. th 1965 – 325 W 18 St: The Associates loans. 1709 Pioneer Ave: State Employment Security Comn emp serv; 1715 Pioneer Ave: Goodwill Industries used mdse; 1719 th th Pioneer Ave, 1721 Pioneer Ave; Vacant. 320 W 17 St: Vacant; 320 ½ W 17 St: th Davis Hotel; 322 W 17 St: Coast to Coast Stores hdw. th th 1975 – 321 W 18 St: Acadia Realty Inc, residence; 325 W 18 St: Associates Financial Serv Co of Wyoing Inc loans. 1715 Pioneer Ave: Davis B Furniture Co. 320 th th ½ W 17 St: Vacant; 322 W 17 St: Goodwill Industry Of Wyoming. th 1985 – 321 W 18 St: Friedberg Jack B financial consultant, American Financial Co, Hercules-Seidel Construction designers bldrs & genl contrs, Sav-On Real Estate; th 325 W 18 St: Associates Financial Services loans. 1715 Pioneer Ave: Capitol th Sewing; 1719 Pioneer Ave: Vacant. 320 W 17 St: Goodwill Industries (Living Skills th Ofc); 322 W 17 St: Goodwill Industries of Wyoming (vocatnl dev cntr). th th 1995 – 321 W 18 St: Westward Sew By Rena; 325 W 18 St: Cheyenne Family Chiropractic. 1715 Pioneer Ave: Plush Cue Family Billiards; 1719 Pioneer Ave: th Father Abraham christian bookstore. 320 W 17 St: Goodwill Indus of Wyoming Inc Responsive ■ Resourceful ■ Reliable 11 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Direction Description th living skills center; 322 W 17 St: Goodwill addl sp. th 2005 – 325 W 18 St: Cheyenne Family Chiropractic chiropractors dc. 1715 Pioneer th Ave: Plush Cue Family Billiards billiard parlors. 322 W 17 St: FCS ACC marriage & family counselors, Frontier Correctional Systems drug detections serv & equip. th 2010 – 325 W 18 St: Cheyenne Family Chiropractic chiropractors dc; residence. 1715 Pioneer Ave: Plush Cue Family Billiards billiard equip/supl, residence. 322 W th 17 St: Cheyenne Transitional CTR correctional institutions, residences. th th 1902 – (Southeast) 319 W 17 St, 321 ½ W 17 St: Residences. 1621 Eddy St: th Residence; 1623 Eddy St: Arcade Saloon. (South): 401 W 17 St: Residence; 409 th th th W 17 St: City Hall; 413-15 W 17 St: Amory; 417 W 17 St: The Sherman Co; 419 th th W 17 St: Connor & Miller. 1620-1622 Eddy St: Residence. (Southwest) 501 W 17 th th St, 509 ½ W 17 St: Residences; 509 W 17 St: Geyser Steam Laundry. th th 1913-14 – (Southeast) 319 W 17 St: Residence. (South) 407 W 17 St: City Hall; th th th 413 W 17 St, 417 W 17 St: Residences; 419 W 17 St: Cheyenne Sign Wks; 421 th th W 17 St: Sherman Co; 423 W 17 St: Cheyenne Trading Co. 1621 Thomes St: th Residence. 1623 Eddy St: The Arcade, residence. (Southwest) 505 W 17 St, 507 W th 17 St: Residences. 1620 Thomes St: Residence. th th 1924 – (Southeast) 319 W 17 St: Cheyenne Stamp & Novelty Works; 321 W 17 St: Residence. 1621 Pioneer Ave, 1623 Pioneer Ave: Residence; 1621 ½ Pioneer th th th Ave: IOOF Hall. (South) 411 W 17 St: Loop Café; 413 W 17 St, 415 W 17 St, 417 th th th th W 17 St, 419 W 17 St: Residences; 421 W 17 St: M & M Garage; 423 W 17 St: th th th Salvation Army. (Southwest) 505 W 17 St, 507 W 17 St, 509 ½ W 17 St: th Residences; 509 W 17 St: Wyo Plmbg & Htg Co. th South th 1933-34 – (Southeast) 319 W 17 St: Modern Beauty Supply; 321 W 17 St: Vacant. 1621 Pioneer Ave: Wyoming Produce Co; 1621 ½ Pioneer Ave: Progress Hall; 1623 th Pioneer Ave: Van‟s Food Store. (South) 405 W 17 St: Snug Harbor lodging hse; th th 407 W 17 St: Yocum Floyd W rstr; 409 W 17 St: Universal Machine Shop; 411 W th th 17 St: Silver Abe 2d hd gds; 413 W 17 St: Smith Body and Fender Wks; th th th residence; 415 W 17 St, 417 W 17 St: Vacant; 419 W 17 St: Ronne Thorwald E th th sign pntr; 421 W 17 St: Swanson Louis plmbr. (Southwest) 505 W 17 St: th th th Cheyenne Mattress Co, 507 W 17 St, 509 ½ W 17 St: Residences; 509 W 17 St: Cheyenne Tent & Awning Co, residences. th th 1945 – (Southeast) 319 W 17 St: Capital Studio photogs, residence; 321 W 17 St: Residence. 1621 Pioneer Ave: Caesar‟s Café; 1621 ½ Pioneer Ave: Vacant; 1623 th th Pioneer Ave: Pioneer Bar. (South): 405 W 17 St: Snug Harbor lodging; 407 W 17 th th St: White House Café; 411 W 17 St: Dreamland Palace restr, residence; 413 W 17 th th St: New Moon Barber Shop; 415 W 17 St: Frontier Plmbg & Htg Co; 417 W 17 St: th Wstn Paint & Glass Co glass dept; 419 W 17 St: Prairie Advertisers-Signs; 421 W th th 17 St: Vacant; 423 W 17 St: The Salvation Army. 1619 Thomes Ave: Salvation th Army Rooms. 1622 Pioneer Ave: D&R Appliances. (Southwest) 509 W 17 St: th Cheyenne Tent & Awning Co, residence; 509 ½ W 17 St: Residences. 1620 Thomes Ave: Woody‟s Frontier Service gas and oil. th th 1955 – (Southeast) 319 W 17 St: Vacant; 321 W 17 St: Residence. 1621 Pioneer th Ave: American Legion Post No 93; 1623 Pioneer Ave: Vacant. (South) 405 W 17 St: Responsive ■ Resourceful ■ Reliable 12 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Direction Description th th Vacant; 411 W 17 St: Dreamland Palace café, residence; 413 W 17 St: th th Rehabilitation Industries Inc; 415 W 17 St: Vacant; 419-21 W 17 St: Cook P S Co; th th th 423 W 17 St: The Salvation Army. (Southwest) 503 W 17 St: Vacant; 509 W 17 th St: Cheyenne Tent & Awning Co, residence; 509 ½ W 17 St: Residence.1620 Thomes Ave: Corson W A Co whol auto parts. th th 1965 – (Southeast) 319 W 17 St: GAPA Lodge; 321 W 17 St: Vacant. (South) 405 th th th W 17 : No return; 419 W 17 St: Cook P S Co plmbs; 423 W 17 St: The Salvation th Army. 1622 Pioneer Ave: Caplan Furn Mart. (Southwest) 509 W 17 St: Cheyenne th Tent & Awning Co; 509 ½ W 17 St: Apartments. 1620 Thomes Ave: Corson W A Co whol auto parts. th th 1975 – (Southeast) 319 W 17 St, 321 W 17 St: Vacant. 1623 Pioneer Ave: Vacant. th th (South) 419 W 17 St: Cook P S Co plmbg cntr; 423 W 17 St: Vacant. 1622 th Pioneer Ave: Dinneen Used Car Lot. (Southwest) 501 W 17 St: Corson W A Co th th auto parts; 509 W 17 St: Cheyenne Tent & Awning Co; 509 ½ W 17 St: Apartments. th th 1985 – (Southeast) 319 W 17 St: City Center Parking Lot. (South) 419 W 17 St: th Dinneen‟s Subaru; 421 W 17 St: Parking Lot. 1622 Pioneer Ave: Dinneen Lincoln th Mercury Subaru sls (Used Car Lot). (Southwest) 501 W 17 St: Parking Lot; 509 W th th 17 St: Vacant; 509 ½ W 17 St: Apartments.1620 Thomes Ave: Modern Trend Beauty School. th 1995 – (Southeast) 319 W 17 St: City Parking Lot. 1601 Pioneer Ave: City Public th th Parking Lot. (South) 419 W 17 St: Dinneen‟s Subaru auto dlrs; 421 W 17 St: th th Parking Lot. (Southwest) 501 W 17 St: Parking Lot; 509-509 ½ W 17 St: Vacant (2 Hses). 1620 Thomes Ave: Modern Trend Beauty School. 2005 – (Southeast) 322 W Lincolnway: Cheyenne Transit Program city government. th (South) 419 W 17 St: Dinneen auto rpr & serv, Dinneen Subaru auto dlrs-new cars. (Southwest) 1620 Thomes Ave: Wyoming Trophy & Engraving trophies-mfrs. 2010 – (Southeast) 322 W Lincolnway: Cheyenne Public City Bus bus lines, Cheyenne Transit Program city government. (Southwest) 1620 Thomes Ave: Wyoming Trophy & Engraving trophies-mfrs. 1902 – 1710 Thomes St: Residence; 1712 Thomes St: W E Dinneen Wrehouse; th th 1720 Thomes St: W E Dinneen Pnt Shop. 502 W 17 St, 508-12 W 17 St: th Residences; 504 W 17 St: Vacant. th 1913-14 – 1722 Thomes St: Wilcox & Son. 500 W 17 St: Geyser Laundry, Cleaning th th & Dye Works; 506 W 17 St, 508 W 17 St: Residences. West 1924 – 1712 Thomes St: F G Smith Motor Co; 1720 Thomes St: Residence. 500 W th 17 St: Geyser Laundry Dry Clng & Dye Works. 1933-34 – 1716 Thomes: Welton Garage auto parts; 1722 Thomes: Cook Peter S th th plmbr. 500 W 17 St: Geyser Laundry; 510 W 17 St: Vacant. th 1945 – 1722 Thomes Ave: Cook P S plmbr. 500 W 17 St: Geyser Laundry. th 1955 – 1716 Thomes Ave: Klipstein Mtrs. 500 W 17 St: Geyser Lndry-Dry Clns Inc. 1965 – 1716 Thomes Ave: Klipstein Motor Sales Inc auto dlrs. Responsive ■ Resourceful ■ Reliable 13 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Direction Description th 1975 – 1716 Thomes Ave: D J‟s Mazda of Cheyenne sls & serv. 506 W 17 St: State Employment Service. th 1985 – 1704 Thomes Ave: Vacant. 504 W 17 St: Downtown West Building; 506 W th 17 St: State Fire Prevention-Elec Safety. 1995 – 1704 Thomes Ave: Coldwell Banker; 1706 Thomes Ave: Smith Glen E & th th Associates attys. 504 W 17 St: Downtown West Building; 506 W 17 St: T C I Cablevision. th 2005 – 504 W 17 St: Adecco employment agencies/opportunit, Affiliated Computer SVC computer serv, Wise Anne,US Plant Protection federal government, Wyoming Society of CPA‟s associations, US Food & Nutrition SVC federal government, ACS th insurance; 506 W 17 St: Bresnan Communications internet serv. th 2010 – 504 W 17 St: Adecco Employment SVC employment contractors, ACS info technology serv. RECs were identified associated with the site including several dry cleaner and laundry businesses, oil and automotive businesses, and a gas station. These businesses are considered RECs due to the potential for past releases of hazardous substances or petroleum products. RECs were identified associated with the adjoining properties including several dry cleaners and laundry businesses, oil companies, gas stations, a photo shop and automotive businesses. These businesses are considered RECs due to the potential for past releases of hazardous substances or petroleum products. 3.4 Historical Fire Insurance Maps Historical fire insurance maps produced by the Sanborn Map Company were requested from HIG to evaluate past uses and relevant characteristics of the site and surrounding properties. HIG provided Sanborn maps as summarized below. Several stores and dwellings and various businesses are shown on the Sanborn maps that were reviewed. Primarily the properties of environmental interest are listed in the table below. 1883 1886 1890 1894 1907 1912 1923 1931 1960 Responsive ■ Resourceful ■ Reliable 14 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Historical Fire Insurance Maps Direction Description 1883: Elephant Corral, Blacksmith, City H & L Co, Crochery Furninture, Millinery, Portions of the site are covered by the map legend. 1886: H & L Truck, Blacksmith, Hose House being built, Millinery 1890: Blacksmith, Pioneer Hook & Ladder, Stable, Warehouse, Millinery 1894: Blacksmith, Pioneer Hook & Ladder, Millinery, Tailor, Stable 1907: Transfer Stable, Pioneer Hook & Ladder, Pest, Blacksmith, Wall Paper & Paint Shop, Bicycle repairing, Cobbler, Chinese Laundry, Stables Site 1912: Creamery with open elevator, Fire Dept., Pioneer Hook & Ladder, Clothing Cleaning, Shooting Gallery, D.G, Furniture 1923: Creamery with electric motor & open elevator, Filling Station with gas tank, Sheet Metal Works, Auto Repairing, Fire Department, Dance Hall, Motorcycle Repairing, Carpenter Shop, Creamery with electric motor, Vulcanizing, Oil in Drums 1931: Creamery with electric motor & open elevator, Boiler Room, Dry Cleaning with electric motor, Solvent Tanks, Auto Sales & Service, Steam Laundry, Fire Department, Gas Tank, Miniature Golf Course & Dance Hall, Ware Room, Carpenter with electric motor, Creamery with electric motor, Auto Body Rep, Sign Printing. 1960: Montgomery Ward with open elevator, Used Auto Sales, Boiler Room, Auto Sales & Service with Machine Shop, Repairing, Bicycle Repairing. 1883: (North) Allen Chapel. (Northeast) Livery. Northwest block not provided. 1886: (North) Blacksmith, African ME Church. (Northeast) G.C. Charlton Livery. Northwest block not provided. 1890: (North) African ME Church, Corral. (Northeast) G.C. Charlton Livery. Northwest block not provided. 1894: (North) African ME Church, Corral. (Northeast) J.M. Neman Livery. Northwest block not provided. 1907: (North) Wood Working with electric motor, Paint Shop, Storage, AME Church. Northeast and northwest block not provided. North 1912: (North) Wood Working with electric motor, Machine Shop with electric motor, Allen AME Church. (Northwest) Tailor, Cheyenne Steam Laundry with Dry Room, Engine. Northeast block not provided. 1923: (Northeast) U.S. Post Office. (North) Auto Top Repairing, To Be Auto Repairing, Allen AME Church. Northwest not provided. 1931: (Northeast) U.S. Post Office. (North) Filling Station with gas tanks (4), Auto Greasing, Auto Sales & Service, Carpenter with electric motor, Allen AME Church. Northwest block not provided. 1960: (Northeast) U.S. Post Office. (North) New Car Service, Used Auto Sales, Allen AME Church. Northwest block not provided. East 1883: Carpenter, Stable 1886: Chinese Laundry (2), Shoe Maker, Carpenter Responsive ■ Resourceful ■ Reliable 15 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Direction Description 1890: Chinese Laundry (2), Shoe Maker, Furniture Upholstery 1894: Chinese Laundry, Carriage Repository, Carpenter, Wallpaper & Paint, Tank 1907: Davis Block, Salvation Army Barracks, Millinery 1912: Photo, Cobbler, Rubber Tires, Millinery 1923: Filling Station, Gas Tank, Oil, Crank Case Service, Vulcanizing, Garage 1931: Machine Shop, Paints & Oils 1960: Goodwill Industries with clothing repair 1883: (South) City Hall Hose House. (Southwest) Blacksmith, Wood Working, Wagon Shop. (Southeast) Saloon, Furniture & Glassware. 1886: (South) Chinese Laundry, Stable, D.G.&c., City Hall Hose House (Southwest) Blacksmith. (Southeast) Saloon. 1890: (South) Chinese Laundry, Coal Shed, Carpenter with Paint Shop, City Hall Hose House and Police Station, D.G&c., Stable (Southwest) Blacksmith, Wagon Shop. (Southeast) Saloon, Furniture & Jewelry. 1894: (South) Chinese Laundry (2), City Hall Hose House and Police Station, Tin Shop, Stable. (Southwest) Blacksmith, Wagon Shop. (Southeast) Furniture & Jewelry, Saloon. South 1907: Rug Fac with electric motor, Paint Shop and Wall Paper, Carpenter, Bottling Works, Geyser Laundry with Dry Room, Jail, Furniture, Stable (Southwest) Blacksmith, Carpenter, Stable. (Southeast) Saloon, Furniture. 1912: (South) Wall Paper, Sign Painting, Bottling Works, Jail, Furniture, Paint Storage. (Southwest) Blacksmith, Carpenter. (Southeast) Saloon, Furniture. 1923: (South) Salvation Army Hall, Auto Repairing (2), Blacksmith, Carpenter Shop. (Southeast) Stores. Southwest block not provided. 1931: (South) Salvation Army Hall, Plumbing (2), Machine Shop with electric motor, Sheet Metal & Tin Shop, Sign Painting, Church of the Nazarene. (Southwest) Dwellings. (Southeast) Stores. 1960: Salvation Army Hall, Parking, Furniture (Southeast) Store, Club. (Southwest) Nothing indicated. 1883: Chinese Laundry, Blacksmith, Wood Works 1886: Chinese Laundry, Blacksmith, Wagon Shop, Agriculture Implements 1890: Chinese Laundry, Blacksmith, Wagon Shop, Agriculture Implements 1894: Chinese Laundry, Blacksmith, Wagon Repository, Agriculture Implements West 1907: Blacksmith, Carpenter, Furniture & Agriculture Implements, Cobbler 1912: Blacksmith, Warehouse, Geyser Laundry 1923: West block not provided 1931: Plumbing, Garage with Auto Repair and gas tank, Gasol & Cleaning with electric motor 1960: Auto Sales & Service, Dry Cleaning, Vacant & Open Fire Damage Responsive ■ Resourceful ■ Reliable 16 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 RECs were identified associated with the site including businesses such as dry cleaners, vulcanizing, gas station, paint shop, and auto repair and service. Gas tanks and solvent tanks also appeared on the site. RECs were identified associated with the adjoining properties including businesses such as dry cleaners, photo shop, oil companies, vulcanizing, gas stations, paint shops, and auto repair and service. Gas tanks were also identified. 3.5 Site Ownership Based on a review of information obtained from Laramie County assessor‟s records, the current site owner is WE Dinneen Incorporated. In addition, previous owners identified included Dinco Land Incorporated (1989-2011). 3.6 Title Search At the direction of the client, a title search was not included as part of the scope of services. Unless notified otherwise, we assume that the client is evaluating this information outside the scope of this report. 3.7 Environmental Liens Environmental lien records recorded against the site were not provided by the client. At the direction of the client, performance of a review of these records was not included as part of the scope of services and unless notified otherwise, we assume that the client is evaluating this information outside the scope of this report. 3.8 Historical and Site Interviews The following individuals were interviewed regarding the current and historical use of the site. Interviewees Interviewer Interviewee/Phone # Carrie Harns and Clay Muirhead, Terracon John Dinneen / 307-2216452 Title Date/Time 04/13/2013 / 11:00 am Owner/Owner Representative 05/01/2013 / 3:30 pm 05/02/2013 / 10:00 am Jennifer Escobedo / 307634-1010 Carrie Terracon Harns, Sara Flanary & Vanessa Young / 307-778-6644 Occupants 05/02/2013 pm / 2:00-2:45 Kyle Hoffdahl / 307-4265015 Responsive ■ Resourceful ■ Reliable 17 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Interview with Mr. John Dinneen Terracon conducted both phone and personal interviews with Mr. John Dinneen, General Manager of W.E. Dinneen, Inc and Dinco Development LLC, to inquire about historical uses and known environmental conditions associated with the site. Mr. Dinneen said that he had owned the property since 1989 and had renovated it in 1991. Mecham Pontiac Buick had owned the property from approximately 1984 to 1989, and Taylor Pontiac Buick had owned it since approximately the early 1920s to 1984. Mr. Dinneen stated that he believed the east portion of the building had been built between approximately 1915 and 1920 and the west portion of the building had been built in approximately 1961 or 1962. The original use of the basement and roof of the west portion was for parking. Mr. Dinneen stated the site building had been used as a car dealership since the early 1920s, but he did not know what it had been used for prior to that. The first floor of the east portion of the building had once contained a belowground hydraulic hoist prior to the Dinneen‟s ownership of the building. Several aboveground electric hoists had been used during the time the Dinneens owned the building. An alignment machine had also been used during the Dinneen years. Additionally, there had been two waste oil heaters used for a short amount of time on the first floor of the east portion of the building. The capacity of the heater tanks was approximately 300 gallons each, and the tanks were used to store waste oil after the heaters were no longer used. Tri-State Oil Recycling was used to dispose of the waste oil. Mr. Dinneen was not aware of any USTs on site. Mr. Dinneen stated that there had been a used oil AST when they bought the building in 1989, but it was hauled off. The basement of the building had been used for heavy duty mechanical work, car body repair, and painting during the Taylor and Mecham years. The Dinneens used the basement for detailing and undercoating only. The Dinneens renovated the building in 1991. Renovations included converting the first floor of the east portion from a showroom to auto work and maintenance and parts department; filling in a majority of the floor drains in the west portion of the basement; improving the storm water system running through the basement floor of the west portion of the building, including the sump (with pump); replacing the groundwater sumps (with pumps) in the basement of the east portion of the building; re-plumbing a floor drain to the sanitary sewer sump (with pump) in the east portion of the basement; improving the south ramp entrance to prevent storm water from entering the building; burying the electrical lines in the alley; and improving the storm water drain system in the alley. The basement had flooded prior to the Dinneens purchasing the property. It was thought to be due to groundwater, so two groundwater pumps were installed in the east portion of the basement. The Dinneens improved the storm water drain system running through the west portion of the basement, including the sump (with pump) along the south wall in the southwest corner of the west portion of the basement, after purchasing the property. Mr. Dinneen stated that the basement did not flood during the time that they have owned the building and that the groundwater sump pumps have never run. Solvent washers had been used in the building, and Safety Kleen was used for disposal and exchange of the used solvent. Antifreeze was stored in the building in 55-gallon drums, and antifreeze had been washed into the floor drains during floor cleanings. Dinneen hauled the sump solids to the landfill. The sumps were tested at a lab approximately every three years for contamination, and the test results never indicated contamination. Responsive ■ Resourceful ■ Reliable 18 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 The east portion of the west parking lot had been owned by Royal Glass prior to the Dinneens purchasing the property from them in 1985. There were two buildings at the south end of the property and an open lot in the north end. The Dinneens tore down the buildings in approximately 1988 or 1989 and resurfaced the lot in 1991. Mr. Dinneen said that the underground electrical connections in the parking lot for the street lights were put in in 1991 as well. Mr. Dinneen stated that the Henry & Boltoff building occupied the east parking lot prior to 1985 when the Dinneens bought the property. The Dinneens tore down the building and filled the basement with clean fill dirt. The lot has been rented to Sidles for parking since 1988 and the lot was surfaced in 1991. Mr. Dinneen said that he was not aware of any dumping, including that of oils or solvents, on the site. He said that the site has been paved for as long as he can remember, so he thought the opportunity for dumping would have been very limited. WE Dinneen Incorporated was not aware of any pending, threatened or past environmental litigation, proceedings or notices of possible violations of environmental laws or liability or potential environmental concerns in connection with the site. When asked about the adjoining properties, Mr. Dinneen stated that there had been a gasoline UST in the street north of the site and a dispenser pump on the sidewalk that Taylor used to fill their cars at the dealership. He said that the only connection the pump and dispenser had to the site was electrical. Mr. Dinneen said that Mecham had the tank removed in 1984 by Hartsook. Mr. Dinneen indicated that there had been several car dealerships, offices and a variety of businesses in the adjoining properties over the years. Mr. Dinneen stated that the northwest adjoining property used to be a dry cleaner, Cheyenne Steam Laundry, and the site was part of the Voluntary Remediation Program. The dry cleaning building was torn down in 1993 or 1994 after which the current bank was built. He also indicated that the east corner of the north adjoining property may have been a gas station at one time. Interview with Ms. Jennifer Escobedo Terracon conducted a personal interview with Ms. Jennifer Escobedo, WSHIIP Program Manager for Wyoming Senior Citizens Inc., to inquire about current use of the property and known environmental conditions. Wyoming Senior Citizens Inc. is the current occupant of 413 W 18th St (Suite D of the Dinneen Building). Ms. Escobedo has been associated with the site for nine months, but stated that Wyoming Senior Citizens Inc. had been the occupant since 1993. The current use of the space is as an office providing services for seniors in the state. Ms. Escobedo was not aware of environmental concerns associated with the site. Interview with Ms. Sara Flanary and Vanessa Young Terracon conducted a personal interview with Ms. Sarah Flanary, Quality Assurance Coordinator for Home Instead Senior Care, and Ms. Vanessa Young, Staffing Coordinator for Home Instead Senior Care, to inquire about current use of the property and known environmental conditions. Home Instead Senior Care is the current occupant of 1723 Thomes Ave, Suite A (Suite A of the Dinneen Building). Ms. Flanary has been associated with the site for 1.5 years and Ms. Young has been associated with the site for 2.5 years. Home Instead Senior Responsive ■ Resourceful ■ Reliable 19 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Care has been the occupant of Suite A since 2007. The current use of the space is as an office for managing in-home care for seniors. Ms. Flanary nor Ms. Young were aware of environmental concerns associated with the site. Interview with Mr. Kyle Hoffdahl Terracon conducted a personal interview with Mr. Kyle Hoffdahl of Domonkos Law Office to inquire about current use of the property and known environmental conditions. Domonkos Law Office is the current occupant of 419 W 18th St (Suite C of the Dinneen Building). Mr. Hoffdahl has been associated with the site since December 2010, and Domonkos Law Office has been the occupant of Suite C since December 2010. The current use of the space is as an office for providing law services. Mr. Hoffdahl was not aware of environmental concerns associated with the site. The occupant of Suite B was unable to be contacted for an interview. 3.9 Prior Report Review Previous environmental reports for the site were not provided by the client to Terracon for review. 3.10 Historical Use Information Summary Based on a review of the historical information, the site was developed prior to 1883. Previous uses of the site included blacksmithing; painting; laundry and dry cleaning; creamery; filling station; vulcanizing; and auto sales, service, repair, and painting. The east portion of the existing building on site was thought to have been constructed between 1915 and 1920 and was used for automobile sales, service, repair, and painting. The west portion of the existing building on-site was constructed in approximately 1961 and was used for automobile sales, service, repair and painting. The site was purchased by Dinneen in 1989 and the building was renovated by Dinneen in 1991. Dinneen used the site for automobile sales, service, repair and painting. The adjoining properties to the north, east, south and west were developed prior to 1883. Previous uses of the adjoining properties to the north included painting; machine repair; steam laundry; a filling station; and auto sales, service, and repair. Previous uses of the adjoining properties to the east included Chinese laundry; photography; tire sales and service; a filling station; automobile service and repair; and machine repair. Previous uses of the adjoining properties to the south included Chinese laundry; painting; blacksmithing; auto repair and machine repair. Previous uses of the adjoining properties to the west included Chinese laundry; blacksmithing; auto sales, service and repair; machine repair; and dry cleaning. The above referenced uses of the site and adjoining properties constitute a REC to the site. Responsive ■ Resourceful ■ Reliable 20 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 4.0 RECORDS REVIEW Regulatory database information was provided by GeoSearch, a contract information services company. The purpose of the records review was to identify RECs in connection with the site. Information in this section is subject to the accuracy of the data provided by the information services company and the date at which the information is updated, and the scope herein did not include confirmation of facilities listed as "unmappable" by regulatory databases. In some of the following subsections, the words up-gradient, cross-gradient and down-gradient refer to the topographic gradient in relation to the site. As stated previously, the groundwater flow direction and the depth to shallow groundwater, if present, would likely vary depending upon seasonal variations in rainfall and the depth to the soil/bedrock interface. Without the benefit of on-site groundwater monitoring wells surveyed to a datum, groundwater depth and flow direction beneath the site cannot be directly ascertained. 4.1 Federal and State/Tribal Databases Listed below are the facility listings identified on federal and state/tribal databases within the ASTM-required search distances from the approximate site boundaries. Database definition, descriptions, and the database search report are included in Appendix D. Federal Databases Radius (miles) Listings Brownfields are real property, the expansion, redevelopment, or reuse of which may be complicated by the presence or potential presence of a hazardous substance, pollutant, or contaminant. Cleaning up and reinvesting in these properties takes development pressures off of undeveloped, open land, and both improves and protects the environment. The United States Environmental Protection Agency maintains this database to track activities in the various brown field grant programs including grantee assessment, site cleanup and site redevelopment. 0.5 0 CERCLIS CERCLIS is the repository for site and non-site specific Superfund information in support of the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA). This United States Environmental Protection Agency database contains an extract of sites that have been investigated or are in the process of being investigated for potential environmental risk. 0.5 1 DNPL This database includes sites from the United States Environmental Protection Agency‟s Final National Priorties List (NPL) where remedies have proven to be satisfactory or sites where the original analyses were inaccurate, and the site is no longer appropriate for inclusion on the NPL, and final publication in the Federal Register has occurred. 1 0 Database Description BF Responsive ■ Resourceful ■ Reliable 21 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Radius (miles) Listings This database includes site locations where Engineering and/or Institutional Controls have been identified as part of a selected remedy for the site as defined by United States Environmental Protection Agency official remedy decision documents. A site listing does not indicate that the institutional and engineering controls are currently in place nor will be in place once the remedy is complete; it only indicates that the decision to include either of them in the remedy is documented as of the completed date of the document. Institutional controls are actions, such as legal controls, that help minimize the potential for human exposure to contamination by ensuring appropriate land or resource use. Engineering controls include caps, barriers, or other device engineering to prevent access, exposure, or continued migration of contamination. Site 0 ERNSWY This National Response Center database contains data on reported releases of oil, chemical, radiological, biological, and/or etiological discharges into the environment anywhere in the United States and its territories. The data comes from spill reports made to the U.S. Environmental Protection Agency, U.S. Coast Guard, the National Response Center and/or the U.S. Department of Transportation. Site 0 LUCIS The LUCIS database is maintained by the U.S. Navy and contains information for former Base Realignment and Closure (BRAC) properties across the United States. 0.5 0 NFRAP This database includes sites which have been determined by the United States Environmental Protection Agency, following preliminary assessment, to no longer pose a significant risk or require further activity under CERCLA. After initial investigation, no contamination was found, contamination was quickly removed or contamination was not serious enough to require Federal Superfund action or NPL consideration. 0.5 1 NLRRCRAG This database includes RCRA Generator facilities that are no longer regulated by the United States Environmental Protection Agency or do not meet other RCRA reporting requirements. 0.125 0 NLRRCRAT This database includes RCRA Non-Corrective Action TSD facilities that are no longer regulated by the United States Environmental Protection Agency or do not meet other RCRA reporting requirements. This listing includes facilities that formerly treated, stored or disposed of hazardous waste. 0.5 1 NPL This database includes United States Environmental Protection Agency (EPA) National Priorities List sites that fall under the EPA's Superfund program, established to fund the cleanup of the most serious uncontrolled or abandoned hazardous waste sites identified for possible long-term remedial action. 1 0 Database Description EC Responsive ■ Resourceful ■ Reliable 22 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Radius (miles) Listings This database contains sites proposed to be included on the National Priorities List (NPL) in the Federal Register. The United States Environmental Protection Agency investigates these sites to determine if they may present long-term threats to public health or the environment. 1 0 RCRAC This database includes hazardous waste sites listed with corrective action activity in the RCRAInfo system. The Corrective Action Program requires owners or operators of RCRA facilities (or treatment, storage, and disposal facilities) to investigate and cleanup contamination in order to protect human health and the environment. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). 1 2 RCRAGR08 This database includes sites listed as generators of hazardous waste (large, small, and exempt) in the RCRAInfo system. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). This database includes sites located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. Large Quantity Generators: Generate 1,000 kg or more of hazardous waste during any calendar month; or Generate more than 1 kg of acutely hazardous waste during any calendar month; or Generate more than 100 kg of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month; or Generate 1 kg or less of acutely hazardous waste during any calendar month, and accumulate more than 1kg of acutely hazardous waste at any time; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste during any calendar month, and accumulated more than 100 kg of that material at any time. Small Quantity Generators: Generate more than 100 and less than 1000 kilograms of hazardous waste during any calendar month and accumulate less than 6000 kg of 0.1 3 Database Description PNPL Responsive ■ Resourceful ■ Reliable 23 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Database Description Radius (miles) Listings 0.5 0 Radius (miles) Listings Site 0 hazardous waste at any time; or Generate 100 kg or less of hazardous waste during any calendar month, and accumulate more than 1000 kg of hazardous waste at any time. Conditionally Exempt Small Quantity Generators: Generate 100 kilograms or less of hazardous waste per calendar month, and accumulate 1000 kg or less of hazardous waste at any time; or Generate one kilogram or less of acutely hazardous waste per calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste. RCRAT This database includes Non-Corrective Action sites listed as treatment, storage and/or disposal facilities of hazardous waste in the RCRAInfo system. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). State/Tribal Databases Database Description IC As defined by the Wyoming Department of Environmental Quality (DEQ), institutional controls are legal or administrative measures that limit human exposure to contaminants. Examples include use control areas, easements, zoning restrictions, and deed notices. They are intended to bolster the integrity of remedies and minimize the potential exposure to contamination by limiting land or resource use. This list of sites with institutional controls in place is provided by the DEQ‟s Voluntary Remediation Program. Responsive ■ Resourceful ■ Reliable 24 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Radius (miles) Listings This listing of active storage tank facilities with contamination is provided by the Wyoming Department of Environmental Quality‟s Storage Tank Program (STP). According to Wyoming Statues 35-11-1414 through 35-111428, the state is responsible for remediation of releases from regulated underground storage tanks and certain aboveground storage tanks. The STP rules and regulations apply to all regulated storage tanks in Wyoming. Storage tank owners/operators are entitled to the state corrective action program if they register their tank(s), pay applicable fees, and complete a minimum site assessment (if applicable). State management of remediation is optional for owners; however, almost no tank system owners have elected to complete cleanup at their expense. 0.5 30 LUSTR08 This database, provided by the United States Environmental Protection Agency (EPA), contains leaking underground storage tanks on Tribal lands located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. 0.5 0 ORPHANS The Orphan Site listing is provided by the Wyoming Department of Environmental Quality (DEQ). Under the Environmental Quality Act “Orphan Sites” are defined as: Sites where the DEQ determines that there is no viable party that is responsible for causing or contributing to the contamination present at the site; Sites where DEQ has issued a no further action letter, and where there is a subsequent discovery of contamination which was present at the site when the no further action letter was issued; Spill sites, where DEQ determines that the person responsible for the spill cannot be identified or where DEQ must take prompt action to prevent hazards to human health or the environment at a site where a responsible party fails to act promptly. 0.5 0 ST This listing contains active and inactive storage tank facilities regulated by the Wyoming Department of Environmental Quality‟s Storage Tank Program (STP). The STP regulates underground storage tanks (USTs) that contain petroleum or hazardous substances; USTs that are larger than 110 gallons or 1,100 gallons on a farm, ranch, or residence; and those that are not heating oil tanks. The STP regulates aboveground storage tanks (ASTs) only if they contain gasoline or diesel, and they are used by a fuel dealer to directly fuel vehicles. The STP does not regulate septic tanks, water storage tanks, hazardous substance ASTs, heating oil tanks, bulk plants, oil refineries, interstate pipeline breakout tanks, or temporary construction ASTs. 0.25 29 SWF This listing of permitted solid waste facilities is provided by the Solid and Hazardous Waste Division (SHWD) of the Wyoming Department of Environmental Quality. The SHWD‟s Solid Waste and Permitting Corrective Action Program is responsible for permitting the location, design, 0.5 2 Database Description LST Responsive ■ Resourceful ■ Reliable 25 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Database Description Radius (miles) Listings construction, operation, monitoring, closure and post-closure care and remediation of solid waste management facilities. The solid waste facilities that are regulated by this program include local community landfills (both operating and closed), municipal waste baling stations and transfer facilities, industrial waste landfills, industrial waste treatment facilities and units, and used oil storage facilities. USTR08 This database, provided by the United States Environmental Protection Agency (EPA), contains underground storage tanks on Tribal lands located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. 0.25 0 VRPBF Wyoming‟s Voluntary Remediation Program (VRP) was created by the Wyoming Legislature in 2000 to create new opportunities, procedures, standards and incentives for voluntary remediation of contaminated properties. In order to encourage more people to participate in the VRP, the Wyoming Department of Environmental Quality (DEQ) obtained a grant from the U.S. Environmental Protection Agency to provide technical assistance (Brownfields Assistance) at brownfield properties that are eligible to participate in Wyoming‟s VRP. This DEQ listing contains both VRP and Brownfield properties. 0.5 8 In addition to the above ASTM-required listings, Terracon reviewed other federal, state, local, and proprietary databases provided by the database firm. A list of the additional reviewed databases is included in the regulatory database report included in Appendix D. The following table summarizes the site-specific information provided by the database and/or gathered by this office for identified facilities. Facilities are listed in order of proximity to the site. Additional discussion for selected facilities follows the summary table. Listed Facilities Facility Name And Location Mecham Pontiac Buick Jeep 1720 Pioneer Avenue Sam Menkin 408 West 18th Dinneen Lincoln Mercury 400 West 16th Street Former Wortham Machinery Co. 517 W. 17th Street Eagles Aerie # 128 Responsive ■ Resourceful ■ Reliable Estimated Distance/Direction/Gradient Site Database Listings WYST, WYLST North Adjoining Property WYST Approximately 0.060 miles S Approximately 0.060 miles SW WYST, USRCRAGR08, WYVRPBF WYVRPBF Approximately 0.070 miles S WYLST 26 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Facility Name And Location Estimated Distance/Direction/Gradient 1600 Thomes Avenue Morris A. Wolin Trust 522 West 16th Street Checker-Yellow Cab Company 1808 O'Neil Avenue Flack Outdoor Advertising, Inc. 423 West 16th Street Goodyear Auto Service Center #81 401 West 16 Street GSA Motor Pool 501 West Lincolnway Laramie County Detention Center 1910 Pioneer Fuel Specialists Corporation 519 West 16th Street P.O. Box 445 Haller's Repair 521 W. Lincolnway Laramie County Government 19th and Carey Avenue Suburban Propane 601 West Lincolnway Union Pacific Railroad 201 West 17Th Street Rutledge Radiator and Welding 621 West Lincolnway AandI MVMS 723 West 19th Street Cheyenne Newspapers, Inc. 702 West Lincolnway Headquarters Fire Station 706 West 19th Street Parking Lot Rocky Mountain FSB 2002 Carey Avenue 709 West Lincolnway, Cheyenne 709 West Lincolnway Cheyenne Main 1919 Capitol Avenue 3D Firestone Store #4855/010456 2001 Carey Avenue DownTown Conoco 1802 Central Avenue Snyder Substation Responsive ■ Resourceful ■ Reliable Database Listings WYST Approximately 0.080 miles S WYST Approximately 0.100 miles W WYST Approximately 0.100 miles S WYST Approximately 0.100 miles S Approximately 0.100 miles S WYST, USRCRAGR08 WYST, WYLST Approximately 0.100 miles NW WYST Approximately 0.110 miles S WYLST Approximately 0.110 miles S USRCRAGR08 Approximately 0.110 miles N WYST, WYLST Approximately 0.130 miles S WYST, WYLST Approximately 0.130 miles E USNLRRCRAT Approximately 0.160 miles SW WYST Approximately 0.180 miles W WYST, WYLST Approximately 0.180 miles SW WYST, WYLST Approximately 0.180 miles W WYST, WYLST Approximately 0.180 miles N WYST, WYLST Approximately 0.190 miles SW WYVRPBF Approximately 0.190 miles NE WYST, WYLST Approximately 0.190 miles N WYST Approximately 0.200 miles NE WYST Approximately 0.210 miles W WYST, WYLST 27 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Facility Name And Location Estimated Distance/Direction/Gradient Database Listings 800 West 18th Street Cheyenne Station 121 West 15th Street Greyhound Lines, Inc. #8203 1503 Capitol Avenue UPRR Railroad Facility 121 W 15th St. Uprr Yard (Vulcan Chem Spill) 121 West 15Th St Emerson Building Emergency Power 2001 Capitol Avenue Cheyenne Landfill (10.080) City Engineers Office, 2101 O'Neil, Cheyenne Transfer Station (50.217) 2101 O''Neil Avenue Jerrys Toppers and Custom Upholstery 803 West Lincolnway Dafc/Mvms 801 West 20th Street Steel Creek Trailer Sales 801 West 19th Street Union Pacific Railroad 105 West 15th Street Big D #32 820 West Lincolnway Cheyenne City Gas Co Snyder Ave & W 18Th St, Se Corner Royal Glass 200 East 17th Fleet Maintenance Department 1500 Snyder Avenue Hardee's Restaurant 216 E. Lincolnway Deluxe Cleaners & Tailors 1614 House Ave. Kum and Go #956 215 East Lincolnway Lincolnway Fast Break 300 East Lincolnway Responsive ■ Resourceful ■ Reliable Approximately 0.220 miles SE WYST, WYLST Approximately 0.220 miles SE WYST Approximately 0.220 miles SE WYVRPBF Approximately 0.220 miles SE USRCRAC Approximately 0.230 miles N WYST Approximately 0.240 miles NW WYSWF Approximately 0.240 miles NW WYSWF Approximately 0.240 miles SW WYST, WYLST Approximately 0.250 miles W WYST Approximately 0.250 miles W WYST, WYLST Approximately 0.250 miles SE WYST, WYLST Approximately 0.260 miles SW WYLST Approximately 0.270 miles SW USCERCLIS, USNFRAP Approximately 0.290 miles E WYLST Approximately 0.310 miles SW WYLST Approximately 0.320 miles E WYVRPBF Approximately 0.330 miles E WYVRPBF Approximately 0.330 miles E WYLST Approximately 0.370 miles E WYLST 28 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Facility Name And Location Snyder Food and Gas 2100 Snyder Avenue E-Z Auto Sales 1001 West 16th Street Barrett Building Emergency Power 2301 Central Avenue Intermountain Safety 1122 West 19th Street Mesic's Conoco 1131 West Lincolnway Cheyenne Village Inn 411 E. 16th Street 2500 Block of Thomes Ave, Cheyenne 2500 Block of Thomes Amerigas 1000 West 23rd Street Amerigas Cheyenne 1021 West 23rd Street Cheyenne Regional Medical Center 300 East 23rd Street Vacant Garage - 502 East Lincolnway 502 East Lincolnway Glacier Park Property - Cheyenne West Of B.N. Rr Yard 1201 W 27Th St Estimated Distance/Direction/Gradient Approximately 0.370 miles W Database Listings WYLST Approximately 0.380 miles SW WYLST Approximately 0.420 miles N WYLST Approximately 0.440 miles W WYLST Approximately 0.450 miles SW WYLST Approximately 0.460 miles E WYVRPBF Approximately 0.500 miles NW WYVRPBF Approximately 0.500 miles W WYLST Approximately 0.500 miles W WYLST Approximately 0.500 miles N WYLST Approximately 0.500 miles E WYLST Approximately 0.790 miles W USRCRAC Mecham Pontiac Buick Jeep, 1720 Pioneer Ave The facility was located on the northeast corner of the site. Mecham Pontiac Buick Jeep was listed in the Storage Tank and Leaking Storage Tank databases. Mr. Adrian Ducharme, WDEQSHWD Storage Tank Program District 1 Supervisor, was contacted about the site. Mr. Ducharme stated that the facility is a resolved contaminated site in respect to gasoline tanks with contamination concentrations below WDEQ clean-up levels. Two 1,000-gallon gasoline USTs were removed on February 14, 1989, and there was reportedly no evidence of a confirmed release of contaminants. One 560-gallon UST was to be filled with an inert material and left in the ground. Based upon the current regulatory status of the site, this facility is a historic REC. Sam Menkin, 408 West 18th This facility is located in the north adjoining property and is listed in the Storage Tank Program. Mr. Adrian Ducharme, WDEQ-SHWD Storage Tank Program District 1 Supervisor, was Responsive ■ Resourceful ■ Reliable 29 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 contacted about the facility and he stated that two 1,000-gallon gasoline USTs were last used in 1989 and both tanks were removed from the ground. He also said that there was no confirmation of a release from the gasoline USTs at the facility. Since USTs were used at the facility, this facility is a historic REC. 2500 Block of Thomes Ave, Cheyenne This facility is located within 0.5 miles of the site and is listed in the Voluntary Remediation Program and Brownfield Sites database. Ms. Cindi Martinez of the WDEQ-SHWD Voluntary Remediation Program was contacted about the facility. Ms. Martinez indicated that the facility is the Cheyenne PCE Plume. The facility is located topographically up-gradient and within the regulatory search radius and thus constitutes a REC. Glacier Park Property-Cheyenne, West of B.N. RR Yard 1201 W 27th St This facility is located within 1 mile of the site and is listed in the Resource Conservation & Recovery Act-Corrective Action Facilities database. The facility is listed as “Not a Generator” in the database report. Ms. Cindi Martinez of the WDEQ-SHWD Voluntary Remediation Program was contacted about the facility. Ms. Martinez did not have information readily available about the facility. This facility is located topographically up-gradient of the site and within the regulatory search radius and thus and indicates a REC. Mr. John Dinneen had mentioned during his interview that the northwest adjoining property was a contaminated site that was part of the Voluntary Remediation Program (VRP); however, this site did not appear in the database search. Ms. Cindi Martinez of the WDEQ-SHWD Voluntary Remediation Program was contacted about this facility. Ms. Martinez stated that work was not conducted under the VRP (and would not show in a database search) because the property changed ownership as a result of foreclosure so the acquiring bank was not held responsible for the contamination. Additional information about the site was not reasonably ascertainable at the time of this report and thus the site constitutes a REC at this time. The remaining facilities listed in the database report do not appear to represent RECs to the site at this time based upon regulatory status, apparent topographic gradient, and/or relative distance from the site. Unmapped facilities are those that do not contain sufficient address or location information to evaluate the facility listing locations relative to the site. The report listed two facilities in the unmapped section. Determining the location of unmapped facilities is beyond the scope of this assessment; however, none of these facilities were identified as the site or adjacent properties. These facilities are listed in the database report in Appendix D. Responsive ■ Resourceful ■ Reliable 30 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 4.2 Local Agency Inquiries 4.2.1 Fire Department The City of Cheyenne Fire & Rescue Department was contacted by phone regarding environmental records or information indicating environmental concerns for the site. Mr. Mark Norford, Division Chief of Prevention and Fire Marshall, stated that the fire department records for the site for the last five years did not indicate calls pertaining to hazardous substances. Additionally, Mr. Norford said that he does not recall calls to the site pertaining to hazardous substances in the last 8 years. 4.2.2 Local/Regional Pollution Control Agency The Wyoming Department of Environmental Quality-Solid & Hazardous Waste Division (WDEQSHWD was contacted by phone regarding environmental records for the site. The information obtained from this agency about the site is summarized in Section 4.1. 4.3 Records Review Summary Selected federal and state environmental regulatory databases as well as responses from state and local regulatory agencies were reviewed. Several facilities were identified in the regulatory databases. Based on distance, environmental setting and/or facility characteristics, the northeast corner of the site, the northwest adjoining property and three topographically upgradient facilities constitute RECs to the site. 5.0 SITE RECONNAISSANCE 5.1 General Site Information Information contained in this section is based on a visual reconnaissance conducted while walking through the site and the accessible interior areas of structures, if any, located on the site. Exhibit 2 in Appendix A is a Site Diagram of the site. Photo documentation of the site at the time of the visual reconnaissance is provided in Appendix E. Credentials of the individuals planning and conducting the site visit are included in Appendix F. Responsive ■ Resourceful ■ Reliable 31 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 General Site Information Site Reconnaissance Field Personnel Carrie Harns Reconnaissance Date April 30, 2013 Weather Conditions Weather Site Contact/Title John Dinneen / General Manager Building Description Building Building Identification Use Dinneen Building (includes basement and roof top parking deck) Offices, storage Approx. Construction Date 1920 (east), 1960 (west) Number Approx. of Stories Size (ft²) 1 69,000 Site Utilities 5.2 Drinking Water City of Cheyenne Board of Public Utilities Wastewater City of Cheyenne Board of Public Utilities Overview of Current Site Occupants and Operations The site includes one building (Dinneen Building) currently used as offices and for storage. The building includes a basement of approximately 24,000 square feet, a first floor of approximately 30,000 square feet, and a roof top parking deck of approximately 15,000 square feet on the west portion of the building. The site also includes two parking lots. The west parking lot is used for paid monthly parking and the east parking lot is rented to Sidles for their parking needs. The northwest portion of the first floor of the building includes four office suites that are occupied by Home Instead Senior Care (Suite A), a real estate office (Suite B), Domonkos Law Office (Suite C), and Wyoming Senior Citizens Inc. (Suite D). 5.3 Site Observations The following table summarizes site observations and interviews. (designated by an “X”) are discussed in more detail following the table. Responsive ■ Resourceful ■ Reliable Affirmative responses 32 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Site Characteristics Category Item or Feature Observed Emergency generators Elevators Site Operations, Processes, and Equipment Air compressors X Hydraulic lifts X Dry cleaning Photo processing Ventilation hoods and/or incinerators Waste treatment systems and/or water treatment systems Heating and/or cooling systems Other processes or equipment Aboveground Chemical or Waste Storage X Aboveground storage tanks Drums, barrels and/or containers 5 gallons X MSDS Underground storage tanks or ancillary UST equipment Underground Chemical or Waste Storage, Drainage or Collection Systems Sumps, cisterns, catch basins and/or dry wells X Grease traps Septic tanks and/or leach fields Oil/water separators X Pipeline markers Interior floor drains Electrical Transformers/ PCBs X Transformers and/or capacitors Other equipment Responsive ■ Resourceful ■ Reliable 33 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 Category Item or Feature Observed Stressed vegetation Stained soil Stained pavement or similar surface Leachate and/or waste seeps Trash, debris and/or other waste materials Releases or Potential Releases Dumping or disposal areas Construction/demolition debris and/or dumped fill dirt Surface water discoloration, odor, sheen, and/or free floating product Strong, pungent or noxious odors Exterior pipe discharges and/or other effluent discharges Surface water bodies Other Notable Site Features Quarries or pits Wells Site Operations, Processes, and Equipment Air compressors One air compressor was observed in the southeast room of the east portion of the basement. The air compressor was located on the concrete floor. Minor staining was observed beneath the air compressor at the time of the site reconnaissance; however, the staining appeared limited to the concrete floor. Hydraulic lifts Floor penetrations for one hydraulic lift unit were observed during the site reconnaissance. The lift was located on the west side of the first floor of the east portion of the building. The penetrations were concrete fills surrounded by metal. The unit appeared to have subsurface components. According to Mr. Dinneen, the unit had subsurface components, but has not been in the building since at least 1989. No evidence of hydraulic fluid releases was observed from the lift at the time of the site visit. Information about the status of the subgrade hydraulic oil tanks was not readily accessible and thus constitutes a REC. Other processes or equipment Floor markings for six aboveground electric hoists were evident during the site reconnaissance. The hoists were located throughout the first floor of the east portion of the building. Floor markings for an alignment machine were located on the north end of the first floor of the east portion of the building. A car exhaust system was observed running along the floor drains on the Responsive ■ Resourceful ■ Reliable 34 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 first floor of the east portion of the building. Floor markings for a paint booth were located in the southwest end of the basement of the west portion of the building. A steam cleaning machine was located in the southwest corner of the basement of the west portion of the building. Several unidentified floor cuts and floor penetrations were evident throughout the building. Evidence of releases from these processes or equipment was not observed at the time of the site visit. However, the soil beneath the unidentified floor cuts could not be observed and constitutes a REC to the site. Aboveground Chemical or Waste Storage Drums, barrels, and/or containers 5 gallons Three empty 55-gallon plastic drums were observed in the southwest corner of the west portion of the basement of the building at the site. Surficial staining was not observed on the drums or on the concrete in the vicinity of the drums. Underground Chemical or Waste Storage, Drainage or Collection Systems Sumps, cisterns, catch basins and/or dry wells Evidence of sumps with pumps was observed throughout the basement during the site reconnaissance. Two groundwater sumps and one sanitary sewer sump were located in the basement of the east portion of the building. One storm water sump and one sanitary sewer sump were located in the southwest corner of the west portion of the basement. Based on information from Mr. Dinneen that these sumps historically contained only water, the sumps do not constitute a REC to the site. Oil/water separators Two oil/water separators were observed during the site reconnaissance; one was located on the first floor of the east portion of the building and the other was located in the basement of the west portion of the building. According to Mr. John Dinneen, the oil/water separators were installed prior to 1989, and were used primarily for collecting floor washings with oil residue. The oil/water separators receive water from the floor drains and discharge to the sanitary sewer system. The condition of the oil/water separators, the use of the oil/water separators prior to 1989, and the current amount of product in the tank are unknown. The maintenance record of the oil/water separators was not available. The oil/water separators constitute a REC to the site. Interior floor drains Interior floor drains were observed at the following site locations: southwest side of the basement of the west portion of the building, first floor ramp exiting to the south, and north and south sides of the east portion of the first floor. The floor drains on the north side of the east portion of the first floor each contain a mini sump. According to Mr. John Dinneen, some of the floor drains discharge to the oil/water separators and then the sanitary sewer, and some of the floor drains discharge directly to the sanitary sewer. Evidence of staining or other releases to the floor drains was not observed during the site reconnaissance. Responsive ■ Resourceful ■ Reliable 35 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 5.4 Site Reconnaissance Summary Based on site reconnaissance, RECs were identified associated with the current site operations including a former underground hydraulic hoist, oil/water separators, and unidentified floor cuts and penetrations. 6.0 ADJOINING PROPERTY RECONNAISSANCE Visual observations of adjoining properties (from site boundaries) are summarized below. Adjoining Properties Direction Description th 500 W 18 St: Security First Bank North First Interstate Bank Parking 1810 Pioneer Ave: Vacant th 314 W 18 St: McGee, Hearne & Piaz, LLP th 325 W 18 St: Offices East 1712 Pioneer Ave: Offices 1715 Pioneer Ave: Plush Cue Family Billiards th 322 W 17 St: Cheyenne Transitional Center Downtown Parking Structure (City) th 400 W 17 St: Sidles Co Complete Auto Parts Store th South 406 W 17 St: Sidles Co th 408 W 17 St: Advance Cash Services th Parking lot (south of W 17 St) 1620 Thomes Ave: Wyoming Trophy & Engraving th West 504 W 17 St: Downtown West Building Parking Lot Indications of RECs were not visually observed with the current use of the adjoining properties. 7.0 ADDITIONAL SERVICES Per the agreed scope of services specified in the proposal, the following additional services were conducted: Asbestos Survey. Please refer to the IHI Environmental Asbestos-Containing Material Field Survey Report (IHI Project No. AM137527) for the findings of these assessments. Responsive ■ Resourceful ■ Reliable 36 Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY April 30, 2013 ■ Terracon Project No. 24137705 8.0 DECLARATION I, Clay Muirhead, P.E., declare that, to the best of my professional knowledge and belief, I meet the definition of Environmental Professional as defined in Section 312.10 of 40 CFR 312; and I have the specific qualifications based on education, training, and experience to assess a property of the nature, history, and setting of the site. I have developed and performed the All Appropriate Inquiries in conformance with the standards and practices set forth in 40 CFR Part 312. Responsive ■ Resourceful ■ Reliable 37 APPENDIX A EXHIBIT 1 – TOPOGRAPHIC MAP EXHIBIT 2 – SITE DIAGRAM EXHIBIT 3 – BUILDING DIAGRAM-FIRST FLOOR EXHIBIT 4 – BUILDING DIAGRAM-BASEMENT APPENDIX B DESCRIPTION OF TERMS AND ACRONYMS Description of Selected General Terms and Acronyms Term/Acronym ACM AHERA AST BGS BTEX CERCLA CERCLIS CESQG CFR DOT Description Asbestos Containing Material. Asbestos is a naturally occurring mineral, three varieties of which (chrysotile, amosite, crocidolite) have been commonly used as fireproofing or binding agents in construction materials. Exposure to asbestos, as well as ACM, has been documented to cause lung diseases including asbestosis (scarring of the lung), lung cancer and mesothelioma (a cancer of the lung lining). Regulatory agencies have generally defined ACM as a material containing greater that one (1) percent asbestos, however some states (e.g. California) define ACM as materials having 0.1% asbestos. In order to define a homogenous material as non-ACM, a minimum number of samples must be collected from the material dependent upon its type and quantity. Homogenous materials defined as non-ACM must either have 1) no asbestos identified in all of its samples or 2) an identified asbestos concentration below the appropriate regulatory threshold. Asbestos concentrations are generally determined using polarized light microscopy or transmission electron microscopy. Point counting is an analytical method to statistically quantify the percentage of asbestos in a sample. The asbestos component of ACM may either be friable or non-friable. Friable materials, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure and have a higher potential for a fiber release than non-friable ACM. Non-friable ACM are materials that are firmly bound in a matrix by plastic, cement, etc. and, if handled carefully, will not become friable. Federal and state regulations require that either all suspect building materials be presumed ACM or that an asbestos survey be performed prior to renovation, dismantling, demolition, or other activities that may disturb potential ACM. Notifications are required prior to demolition and/or renovation activities that may impact the condition of ACM in a building. ACM removal may be required if the ACM is likely to be disturbed or damaged during the demolition or renovation. Abatement of friable or potentially friable ACM must be performed by a licensed abatement contractor in accordance with state rules and NESHAP. Additionally, OSHA regulations for work classification, worker training and worker protection will apply. Asbestos Hazard Emergency Response Act Above Ground Storage Tanks. ASTs are generally described as storage tanks less than 10% of which are below ground (i.e., buried). Tanks located in a basement, but not buried, are also considered ASTs. Whether, and the extent to which, an AST is regulated, is determined on a case-by-case basis and depends upon tank size, its contents and the jurisdiction of its location. Below Ground Surface Benzene, Toluene, Ethylbenzene, and Xylenes. BTEX are VOC components found in gasoline and commonly used as analytical indicators of a petroleum hydrocarbon release. Comprehensive Environmental Response, Compensation and Liability Act (a.k.a. Superfund). CERCLA is the federal act that regulates abandoned or uncontrolled hazardous waste sites. Under this Act, joint and several liability may be imposed on potentially responsible parties for cleanup-related costs. Comprehensive Environmental Response, Compensation and Liability Information System. An EPA compilation of sites having suspected or actual releases of hazardous substances to the environment. CERCLIS also contains information on site inspections, preliminary assessments and remediation of hazardous waste sites. These sites are typically reported to EPA by states and municipalities or by third parties pursuant to CERCLA Section 103. Conditionally exempt small quantity generators. Code of Federal Regulations U.S. Department of Transportation Description of Selected General Terms and Acronyms (cont.) Term/Acronym EPA ERNS ESA FRP Hazardous Substance Hazardous Waste ILP LQG LUST MCL MSDS NESHAP NFRAP NOV NPDES NPL OSHA PACM Description U.S. Environmental Protection Agency Emergency Response Notification System. An EPA-maintained federal database which stores information on notifications of oil discharges and hazardous substance releases in quantities greater than the applicable reportable quantity under CERCLA. ERNS is a cooperative datasharing effort between EPA, DOT, and the National Response Center. Environmental Site Assessment Fiberglass Reinforced Plastic As defined under CERCLA, this is (A) any substance designated pursuant to section 1321(b)(2)(A) of Title 33, (B) any element, compound, mixture, solution, or substance designated pursuant to section 9602 of this title; (C) any hazardous waste having characteristics identified under or listed pursuant to section 3001 of the Solid Waste Disposal Act (with some exclusions); (D) any toxic pollutant listed under section 1317(a) of Title 33; (E) any hazardous air pollutant listed under section 112 of the Clean Air Act; and (F) any imminently hazardous chemical substance or mixture with respect to which the EPA Administrator has taken action under section 2606 of Title 15. This term does not include petroleum, including crude oil or any fraction thereof which is not otherwise listed as a hazardous substance under subparagraphs (A) through (F) above, and the term include natural gas, or synthetic gas usable for fuel (or mixtures of natural gas and such synthetic gas). This is defined as having characteristics identified or listed under section 3001 of the Solid Waste Disposal Act (with some exceptions). RCRA, as amended by the Solid Waste Disposal Act of 1980, defines this term as a “solid waste, or combination of solid wastes, which because of its quantity, concentration, or physical, chemical, or infectious characteristics may (A) cause, or significantly contribute to an increase in mortality or an increase in serious irreversible, or incapacitating reversible illness; or (B) pose a substantial present or potential hazard to human health or the environment when improperly treated, stored, transported, or disposed of, or otherwise managed.” Innocent Landowner/Operator Program Large quantity generators. Leaking Underground Storage Tank. This is a federal term set forth under RCRA for leaking USTs. Some states also utilize this term. Maximum Contaminant Level. This Safe Drinking Water concept (and also used by many states as a ground water cleanup criteria) refers to the limit on drinking water contamination that determines whether a supplier can deliver water from a specific source without treatment. Material Safety Data Sheets. Written/printed forms prepared by chemical manufacturers, importers and employers which identify the physical and chemical traits of hazardous chemicals under OSHA‟s Hazard Communication Standard. National Emissions Standard for Hazardous Air Pollutants (Federal Clean Air Act). This part of the Clean Air Act regulates emissions of hazardous air pollutants. Facilities where there is “No Further Remedial Action Planned,” as more particularly described under the Records Review section of this report. Notice of Violation. A notice of violation or similar citation issued to an entity, company or individual by a state or federal regulatory body indicating a violation of applicable rule or regulations has been identified. National Pollutant Discharge Elimination System (Clean Water Act). The federal permit system for discharges of polluted water. National Priorities List, as more particularly described under the Records Review section of this report. Occupational Safety and Health Administration or Occupational Safety and Health Act Presumed Asbestos-Containing Material. A material that is suspected of containing or presumed to contain asbestos but which has not been analyzed to confirm the presence or absence of asbestos. Description of Selected General Terms and Acronyms (cont.) Term/Acronym PCB pCi/l PLM PST Radon RCRA RCRA Generators RCRA CORRACTS/TS Ds RCRA NonCORRACTS/TS Ds RCRA Violators List RCRIS REC SCL Description Polychlorinated Biphenyl. A halogenated organic compound commonly in the form of a viscous liquid or resin, a flowing yellow oil, or a waxy solid. This compound was historically used as dielectric fluid in electrical equipment (such as electrical transformers and capacitors, electrical ballasts, hydraulic and heat transfer fluids), and for numerous heat and fire sensitive applications. PCB was preferred due to its durability, stability (even at high temperatures), good chemical resistance, low volatility, flammability, and conductivity. PCBs, however, do not break down in the environment and are classified by the EPA as a suspected carcinogen. 1978 regulations, under the Toxic Substances Control Act, prohibit manufacturing of PCB-containing equipment; however, some of this equipment may still be in use today. Pico Curies per Liter of Air. Unit of measurement for Radon and similar radioactive materials. Polarized Light Microscopy (see ACM section of the report, if included in the scope of services) Petroleum Storage Tank. An AST or UST that contains a petroleum product. A radioactive gas resulting from radioactive decay of naturally-occurring radioactive materials in rocks and soils containing uranium, granite, shale, phosphate, and pitchblende. Radon concentrations are measured in Pico Curies per Liter of Air. Exposure to elevated levels of radon creates a risk of lung cancer; this risk generally increases as the level of radon and the duration of exposure increases. Outdoors, radon is diluted to such low concentrations that it usually does not present a health concern. However, radon can accumulate in building basements or similar enclosed spaces to levels that can pose a risk to human health. Indoor radon concentrations depend primarily upon the building's construction, design and the concentration of radon in the underlying soil and ground water. The EPA recommended annual average indoor “action level” concentration for residential structures is 4.0 pCi/l. Resource Conservation and Recovery Act. Federal act regulating solid and hazardous wastes from point of generation to time of disposal („cradle to grave”). 42 U.S.C. 6901 et seq. The RCRA generators list is part of the RCRIS database maintained by EPA and lists facilities that generate hazardous waste as part of their normal business operations, as more particularly defined under Section 4.1 of this report. The USEPA maintains a database of RCRA facilities associated with treatment, storage, and disposal (TSD) of hazardous materials which are undergoing “corrective action”. A “corrective action” order is issued when there is a release of hazardous waste or constituents into the environment from a RCRA facility. The RCRA Non-CORRACTS/TSD Database is a compilation by the USEPA of facilities which report storage, transportation, treatment, or disposal of hazardous waste. Unlike the RCRA CORRACTS/TSD database, the RCRA Non-CORRACTS/TSD database does not include RCRA facilities where corrective action is required. RAATS. RCRA Administrative Actions Taken. RAATS information is now contained in the RCRIS database and includes records of administrative enforcement actions against facilities for noncompliance. Resource Conservation and Recovery Information System, as defined in the Records Review section of this report. Recognized Environmental Conditions” are defined by ASTM E1527-05 as “the presence or likely presence of any hazardous substances or petroleum products on a property under conditions that indicate an existing release, a past release, or a material threat of release of any hazardous substances or petroleum products into structures on the property or into the ground, ground water, or surface water of the property. The term includes hazardous substances or petroleum products even under conditions of compliance with laws. The term is not intended to include de minimis conditions that generally do not present a threat to human health or the environment and that generally would not be the subject of an enforcement action if brought to the attention of appropriate governmental agencies.” State “CERCLIS” List (see SPL /State Priority List, below). Description of Selected General Terms and Acronyms (cont.) Term/Acronym SPCC SPL SQG SWF TPH TRI TSCA USACE USC USGS USNRCS UST VCP VOC Wetlands Description Spill Prevention, Control and Countermeasures. SPCC plans are required under federal law (Clean Water Act and Oil Pollution Act) for any facility storing petroleum in tanks and/or containers of 55-gallons or more that when taken in aggregate exceed 1,320 gallons. SPCC plans are also required for facilities with underground petroleum storage tanks with capacities of over 42,000 gallons. Many states have similar spill prevention programs, which may have additional requirements. State Priority List. State list of confirmed sites having contamination in which the state is actively involved in clean up activities or is actively pursuing potentially responsible parties for clean up. Sometimes referred to as a State “CERCLIS” List. Small quantity generator. Solid Waste Facility Total Petroleum Hydrocarbons Toxic Release Inventory. Routine EPA report on releases of toxic chemicals to the environment based upon information submitted by entities subject to reporting under the Emergency Planning and Community Right to Know Act. Toxic Substances Control Act. A federal law regulating manufacture, import, processing and distribution of chemical substances not specifically regulated by other federal laws (such as asbestos, PCBs, lead-based paint and radon). 15 U.S.C 2601 et seq. United States Army Corps of Engineers United States Code United States Geological Survey United States Department of Agriculture-Natural Resource Conservation Service Underground Storage Tank. Most federal and state regulations, as well as ASTM E1527-05, define this as any tank, incl., underground piping connected to the tank, that is or has been used to contain hazardous substances or petroleum products and the volume of which is 10% or more beneath the surface of the ground (i.e., buried). Voluntary Cleanup Program Volatile Organic Compound Areas that are typically saturated with surface or ground water that creates an environment supportive of wetland vegetation (i.e., swamps, marshes, bogs). The Corps of Engineers Wetlands Delineation Manual (Technical Report Y-87-1) defines wetlands as areas inundated or saturated by surface or ground water at a frequency and duration sufficient to support, and that under normal circumstances do support, a prevalence of vegetation typically adapted for life in saturated soil conditions. For an area to be considered a jurisdictional wetland, it must meet the following criteria: more than 50 percent of the dominant plant species must be categorized as Obligate, Facultative Wetland, or Facultative on lists of plant species that occur in wetlands; the soil must be hydric; and, wetland hydrology must be present. The federal Clean Water Act which regulates “waters of the US,” also regulates wetlands, a program jointly administered by the USACE and the EPA. Waters of the U.S. are defined as: (1) waters used in interstate or foreign commerce, including all waters subject to the ebb and flow of tides; (2) all interstate waters including interstate wetlands; (3) all other waters such as intrastate lakes, rivers, streams (including intermittent streams), mudflats, sandflats, wetlands, sloughs, prairie potholes, wet meadows, playa lakes, or natural ponds, etc., which the use, degradation, or destruction could affect interstate/ foreign commerce; (4) all impoundments of waters otherwise defined as waters of the U. S., (5) tributaries of waters identified in 1 through 4 above; (6) the territorial seas; and (7) wetlands adjacent to waters identified in 1 through 6 above. Only the USACE has the authority to make a final wetlands jurisdictional determination. APPENDIX C HISTORICAL DOCUMENTATION AND USER QUESTIONNAIRE historicalinfo.com New Cheyenne Public Safety Center W 17th St and Pioneer Ave Cheyenne, WY ´ 2012 HIG Project # 132599 Client Project # 24137705 Approximate Scale 1:6000 (1"=500') historicalinfo.com New Cheyenne Public Safety Center W 17th St and Pioneer Ave Cheyenne, WY ´ 2006 HIG Project # 132599 Client Project # 24137705 Approximate Scale 1:6000 (1"=500') historicalinfo.com New Cheyenne Public Safety Center W 17th St and Pioneer Ave Cheyenne, WY ´ 1994 HIG Project # 132599 Client Project # 24137705 Approximate Scale 1:6000 (1"=500') historicalinfo.com New Cheyenne Public Safety Center W 17th St and Pioneer Ave Cheyenne, WY ´ 1990 HIG Project # 132599 Client Project # 24137705 Approximate Scale 1:9600 (1"=800') historicalinfo.com New Cheyenne Public Safety Center W 17th St and Pioneer Ave Cheyenne, WY ´ 1960 HIG Project # 132599 Client Project # 24137705 Approximate Scale 1:6000 (1"=500') historicalinfo.com New Cheyenne Public Safety Center W 17th St and Pioneer Ave Cheyenne, WY ´ 1947 HIG Project # 132599 Client Project # 24137705 Approximate Scale 1:9600 (1"=800') APPENDIX D ENVIRONMENTAL DATABASE INFORMATION Radius Report http://www.geo-search.net/QuickMap/index.htm?DataID=Standard0000056685 Click on link above to access the map and satellite view of current property Target Property: New Cheyenne Public Safety Center W 17th St and Pioneer Ave Cheyenne, Laramie County, Wyoming 82001 Prepared For: Historical Information Gatherers, Inc. Order #: 24902 Job #: 56685 Project #: 132599 Date: 04/29/2013 phone: 888-396-0042 · fax: 512-472-9967 · www.geo-search.com TARGET PROPERTY SUMMARY New Cheyenne Public Safety Center W 17th St and Pioneer Ave Cheyenne, Laramie County, Wyoming 82001 USGS Quadrangle: Cheyenne North, WY Target Property Geometry:Area Target Property Longitude(s)/Latitude(s): (-104.818780, 41.133552), (-104.818780, 41.133552), (-104.819660, 41.133222), (-104.819225, 41.132502), (-104.818682, 41.132689), (-104.818904, 41.133036), (-104.818815, 41.133062), (-104.818709, 41.132884), (-104.818424, 41.132991), (-104.818548, 41.133187), (-104.818904, 41.133080), (-104.818958, 41.133187), (-104.818620, 41.133311), (-104.818780, 41.133543), (-104.818780, 41.133552) County/Parish Covered: Laramie (WY) Zipcode(s) Covered: Cheyenne WY: 82001, 82007 State(s) Covered: WY *Target property is located in Radon Zone 1. Zone 1 areas have a predicted average indoor radon screening level greater than 4 pCi/L (picocuries per liter). This report was designed by GeoSearch to meet or exceed the records search requirements of the All Appropriate Inquires Rule (40 CFR §312.26) and the current version of the ASTM International E1527, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process or, if applicable, the custom requirements requested by the entity that ordered this report. The records and databases of records used to compile this report were collected from various federal,state and local governmental entities. It is the goal of GeoSearch to meet or exceed the 40 CFR §312.26 and E1527 requirements for updating records by using the best available technology. GeoSearch contacts the appropriate governmental entities on a recurring basis. Depending on the frequency with which a record source or database of records is updated by the governmental entity, the data used to prepare this report may be updated monthly, quarterly, semi-annually, or annually. Disclaimer - The information provided in this report was obtained from a variety of public sources. GeoSearch cannot ensure and makes no warranty or representation as to the accuracy, reliability, quality, errors occurring from data conversion or the customer’s interpretation of this report. This report was made by GeoSearch for exclusive use by its clients only. Therefore, this report may not contain sufficient information for other purposes or parties. GeoSearch and its partners, employees, officers and independent contractors cannot be held liable for actual, incidental, consequential, special or exemplary damages suffered by a customer resulting directly or indirectly from any information provided by GeoSearch. www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DATABASE FINDINGS SUMMARY DATABASE ACRONYM LOCA- UNLOCATABLE TABLE SEARCH RADIUS (miles) FEDERAL AEROMETRIC INFORMATION RETRIEVAL SYSTEM / AIR FACILITY AIRSAFS 0 0 Target Property SUBSYSTEM BIENNIAL REPORTING SYSTEM BRS 0 0 Target Property CLANDESTINE DRUG LABORATORY LOCATIONS CDL 0 0 Target Property EPA DOCKET DATA DOCKETS 0 0 Target Property FEDERAL ENGINEERING INSTITUTIONAL CONTROL SITES EC 0 0 Target Property EMERGENCY RESPONSE NOTIFICATION SYSTEM ERNSWY 0 0 Target Property FACILITY REGISTRY SYSTEM FRSWY 0 0 Target Property HAZARDOUS MATERIALS INCIDENT REPORTING SYSTEM HMIRSR08 0 0 Target Property 0 0 Target Property ICISNPDES 0 0 Target Property MATERIAL LICENSING TRACKING SYSTEM MLTS 0 0 Target Property NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM NPDESR08 0 0 Target Property PCB ACTIVITY DATABASE SYSTEM PADS 0 0 Target Property PERMIT COMPLIANCE SYSTEM PCSR08 0 0 Target Property RCRA SITES WITH CONTROLS RCRASC 0 0 Target Property CERCLIS LIENS SFLIENS 0 0 Target Property SECTION SEVEN TRACKING SYSTEM SSTS 0 0 Target Property TOXICS RELEASE INVENTORY TRI 0 0 Target Property TOXIC SUBSTANCE CONTROL ACT INVENTORY TSCA 0 0 Target Property NO LONGER REGULATED RCRA GENERATOR FACILITIES NLRRCRAG 0 0 Target Property and Adjoining RESOURCE CONSERVATION & RECOVERY ACT - GENERATOR RCRAGR08 3 0 Target Property and Adjoining HISTORICAL GAS STATIONS HISTPST 0 0 0.2500 BROWNFIELDS MANAGEMENT SYSTEM BF 0 0 0.5000 COMPREHENSIVE ENVIRONMENTAL RESPONSE, CERCLIS 1 0 0.5000 INTEGRATED COMPLIANCE INFORMATION SYSTEM (FORMERLY ICIS DOCKETS) INTEGRATED COMPLIANCE INFORMATION SYSTEM NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM FACILITIES COMPENSATION & LIABILITY INFORMATION SYSTEM www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DATABASE FINDINGS SUMMARY 1 DATABASE FINDINGS SUMMARY LOCA- UNLOCATABLE TABLE SEARCH RADIUS (miles) DATABASE ACRONYM LAND USE CONTROL INFORMATION SYSTEM LUCIS 0 0 0.5000 NO FURTHER REMEDIAL ACTION PLANNED SITES NFRAP 1 0 0.5000 NO LONGER REGULATED RCRA NON-CORRACTS TSD FACILITIES NLRRCRAT 1 0 0.5000 OPEN DUMP INVENTORY ODI 0 0 0.5000 RESOURCE CONSERVATION & RECOVERY ACT - TREATMENT, RCRAT 0 0 0.5000 DELISTED NATIONAL PRIORITIES LIST DNPL 0 0 1.0000 DEPARTMENT OF DEFENSE SITES DOD 0 0 1.0000 FORMERLY USED DEFENSE SITES FUDS 0 0 1.0000 NO LONGER REGULATED RCRA CORRECTIVE ACTION NLRRCRAC 0 0 1.0000 NATIONAL PRIORITIES LIST NPL 0 0 1.0000 PROPOSED NATIONAL PRIORITIES LIST PNPL 0 0 1.0000 RESOURCE CONSERVATION & RECOVERY ACT - CORRECTIVE RCRAC 2 0 1.0000 RODS 0 0 1.0000 8 0 STORAGE & DISPOSAL FACILITIES FACILITIES ACTION FACILITIES RECORD OF DECISION SYSTEM SUB-TOTAL STATE (WY) SITES WITH INSTITUTIONAL CONTROLS IN PLACE IC 0 0 Target Property STORAGE TANKS ST 29 1 0.2500 LEAKING STORAGE TANKS LST 30 1 0.5000 ORPHAN SITES ORPHANS 0 0 0.5000 PERMITTED SOLID WASTE FACILITIES SWF 2 0 0.5000 8 0 0.5000 69 2 0 0 VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES VRPBF SUB-TOTAL TRIBAL UNDERGROUND STORAGE TANKS ON TRIBAL LANDS USTR08 0.2500 www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DATABASE FINDINGS SUMMARY 2 DATABASE FINDINGS SUMMARY LOCA- UNLOCATABLE TABLE SEARCH RADIUS (miles) DATABASE ACRONYM LEAKING UNDERGROUND STORAGE TANKS ON TRIBAL LANDS LUSTR08 0 0 0.5000 OPEN DUMP INVENTORY ON TRIBAL LANDS ODINDIAN 0 0 0.5000 INDIAN RESERVATIONS INDIANRES 0 0 1.0000 0 0 77 2 SUB-TOTAL TOTAL www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DATABASE FINDINGS SUMMARY 3 LOCATABLE DATABASE FINDINGS ACRONYM Target Property SEARCH RADIUS (miles) 1/8 Mile (> TP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2) > 1 Mile Total FEDERAL AIRSAFS .0200 0 0 0 0 NS 0 BRS .0200 0 0 0 0 NS 0 CDL .0200 0 0 0 0 NS 0 DOCKETS .0200 0 0 0 0 NS 0 EC .0200 0 0 0 0 NS 0 ERNSWY .0200 0 0 0 0 NS 0 FRSWY .0200 0 0 0 0 NS 0 HMIRSR08 .0200 0 0 0 0 NS 0 ICIS .0200 0 0 0 0 NS 0 ICISNPDES .0200 0 0 0 0 NS 0 MLTS .0200 0 0 0 0 NS 0 NPDESR08 .0200 0 0 0 0 NS 0 PADS .0200 0 0 0 0 NS 0 PCSR08 .0200 0 0 0 0 NS 0 RCRASC .0200 0 0 0 0 NS 0 SFLIENS .0200 0 0 0 0 NS 0 SSTS .0200 0 0 0 0 NS 0 TRI .0200 0 0 0 0 NS 0 TSCA .0200 0 0 0 0 NS 0 NLRRCRAG .1250 0 0 0 0 NS 0 RCRAGR08 .1250 3 0 0 0 NS 3 HISTPST .2500 0 0 0 0 NS 0 BF .5000 0 0 0 0 NS 0 CERCLIS .5000 0 0 1 0 NS 1 LUCIS .5000 0 0 0 0 NS 0 NFRAP .5000 0 0 1 0 NS 1 NLRRCRAT .5000 0 1 0 0 NS 1 www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 LOCATABLE DATABASE FINDINGS 1 LOCATABLE DATABASE FINDINGS ACRONYM Target Property SEARCH RADIUS (miles) 1/8 Mile (> TP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2) > 1 Mile Total ODI .5000 0 0 0 0 NS 0 RCRAT .5000 0 0 0 0 NS 0 DNPL 1.000 0 0 0 0 NS 0 DOD 1.000 0 0 0 0 NS 0 FUDS 1.000 0 0 0 0 NS 0 NLRRCRAC 1.000 0 0 0 0 NS 0 NPL 1.000 0 0 0 0 NS 0 PNPL 1.000 0 0 0 0 NS 0 RCRAC 1.000 0 1 0 1 NS 2 RODS 1.000 0 0 0 0 NS 0 3 2 2 1 0 8 .0200 0 0 0 0 NS 0 SUB-TOTAL STATE (WY) IC ST 1 .2500 11 17 0 0 NS 29 LST 1 .5000 4 11 14 0 NS 30 ORPHANS .5000 0 0 0 0 NS 0 SWF .5000 0 2 0 0 NS 2 VRPBF .5000 2 2 4 0 NS 8 17 32 18 0 0 69 SUB-TOTAL 2 TRIBAL USTR08 .2500 0 0 0 0 NS 0 LUSTR08 .5000 0 0 0 0 NS 0 ODINDIAN .5000 0 0 0 0 NS 0 INDIANRES 1.000 0 0 0 0 NS 0 0 0 0 0 0 0 20 34 20 1 0 77 SUB-TOTAL TOTAL 2 NOTES: NS = NO SEARCH REQUESTED BY CUSTOMER www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 LOCATABLE DATABASE FINDINGS 2 RADIUS MAP Cheyenne Cheyenne Regional Regional Airport Airport 1 Mile W 2nd Ave E Pershing Blvd e Av ve de r rA xw Ma e Av ell 28 St E1 20 ’26 9t h St E1 ’ 17& S 6th t 1/8 Mile ley Av e Av S th t Hw 5 y8 E5 e e ll t th S US ay lnw co n i L d Bra ss Ru E9 E7 m De W 1/4 Mile t e Av Old Happy Jack Rd S rd ans Ev 21 0 23 &48 &42 2nd x an Al e ve Hw y ⊗ 49 1/2 Mile E2 &19 34 &47 ’22 & 37 11 & 8 ’ 39 ⊗ 45 &40 18 ⊗ & 36⊗ 38 2’ & 31’ & &1 "13 15& ’9 30& 23 3 25’ & " 5 " &43 33( 4’ % %&29 & " " 7 ’ 16 &’&&6 10 24 32& ⊗ &21 14 12 & 41& 35 27 44& &46 &50 e St ve W St at ve h 26 t ou ym lA yA W rA yde Sn % %51 Se tra all Av e re Ca I 25 n Ce Cribbon Ave Ra nd t th S in g Dr Parsley Blvd Snyder Ave E3 rd St E 1st St I 80 Target Property (TP) & LST ’ ST " " RCRAGR08 " ⊗ % % NLRRCRAT New Cheyenne Public Safety Center W 17th St and Pioneer Ave Cheyenne, Wyoming 82001 VRPBF RCRAC 0' 1000' SWF ( CERCLIS SCALE: 1" = 2000' www.geo-search.com - phone: 888-396-0042 - fax: 512-472-9967 JOB #: 56685 - 4/29/2013 2000' 3000' RADIUS MAP nda l re Ca Ra E2 ve rA ve 0t h St E1 9t h e Av ell e Av 1/8 Mile 20 ’ 26 17 &’ & 19 ’ 22 & 11 ’8 E2 xw Ma Ave e Av e Av 28 & 40 se nt 50 u Ho Be 46 ve 1/4 Mile e Av e Av & & lA ve ed es om Th Re t ans Ev pit o rA e Av ee e il ve W S rd 48 & 42 Ca n Pio On rA yde Sn W 2 St 4th ou ym & t ⊗ 49 23 St Se hS 26 t 1/2 Mile en enn nL Va W 2nd yA l Av e St 8th E1 lo Dil 18 2 ’ ’ & 31 & 1 " 13 15 & ’ 9 30 & & 3 23 25 ’ & " " 5 29 & 43 ( % % " 7 4 ’& ’" 33 &16 & & 10 24 ’ 6 t S ⊗ th 32 & 12 17 W & 14 & 21 41 & 35 27 44 & nA ve sA e Av e Am y De & 47 34 37 & ⊗ & 39 ⊗ 45 ⊗ 36 & 38 ve 5 Hw y2 10 S th 8 Hwy US te Sta W 16 t Ave es Am y wa o ln Deming Dr W 10 th S t Sn Target Property (TP) & LST ’ ST " " RCRAGR08 " ⊗ % % NLRRCRAT New Cheyenne Public Safety Center W 17th St and Pioneer Ave Cheyenne, Wyoming 82001 VRPBF RCRAC 0' 500' SWF ( CERCLIS SCALE: 1" = 1000' www.geo-search.com - phone: 888-396-0042 - fax: 512-472-9967 JOB #: 56685 - 4/29/2013 1000' 1500' TOPOGRAPHIC MAP 1 Mile 1/2 Mile 1/4 Mile 1/8 Mile Target Property (TP) Quadrangle(s): Cheyenne North Source: USGS, 1992 New Cheyenne Public Safety Center W 17th St and Pioneer Ave Cheyenne, Wyoming 82001 0' 1000' SCALE: 1" = 2000' www.geo-search.com - phone: 888-396-0042 - fax: 512-472-9967 JOB #: 56685 - 4/29/2013 2000' 3000' REPORT SUMMARY OF LOCATABLE SITES MAP DATABASE ID# NAME SITE ID# DISTANCE FROM SITE 1 ST 0-000012 0.010 SE 1 LST 12 2 ST 3 CITY, ZIP CODE PAGE # MECHAM PONTIAC BUICK 1720 PIONEER AVENUE JEEP CHEYENNE, 82001 1 0.010 SE MECHAM PONTIAC BUICK 1720 PIONEER AVENUE JEEP CHEYENNE, 82001 2 0-003686 0.030 NW SAM MENKIN 408 WEST 18TH CHEYENNE, 82001 3 ST 0-003251 0.060 S DINNEEN LINCOLN MERCURY 400 WEST 16TH STREET CHEYENNE, 82001 4 3 VRPBF 2139 0.060 S DINNEEN PROPERTY 400 WEST 16TH STREET CHEYENNE 5 3 RCRAGR08 WYD036001873 0.060 S DINNEEN LINCOLN MERCURY SUBARU 400 WEST 16TH STREET CHEYENNE, 82001 6 4 VRPBF 2056 0.060 SW FORMER WORTHAM MACHINERY CO. 517 W. 17TH STREET CHEYENNE 8 4 ST 0-001342 0.080 S MORRIS A. WOLIN TRUST 522 WEST 16TH STREET CHEYENNE, 82001 9 5 ST 0-004335 0.070 S EAGLES AERIE # 128 1600 THOMES AVENUE CHEYENNE, 82001 10 5 LST 4335 0.070 S EAGLES AERIE # 128 1600 THOMES AVENUE CHEYENNE, 82001 11 6 LST 5054 0.100 S GSA MOTOR POOL 501 WEST LINCOLNWAY CHEYENNE, 82001 12 6 LST 164 0.110 S FUEL SPECIALISTS CORPORATION 519 WEST 16TH STREET P.O. BOX CHEYENNE, 82001 445 13 6 ST 0-005054 0.100 S GSA MOTOR POOL 501 WEST LINCOLNWAY CHEYENNE, 82001 14 6 ST 0-000164 0.110 S FUEL SPECIALISTS CORPORATION 519 WEST 16TH STREET P. O. BOX 445 CHEYENNE, 82001 15 6 RCRAGR08 WYR000212449 0.110 S HALLER'S REPAIR 521 W. LINCOLNWAY CHEYENNE, 82001 16 7 ST 0-005047 0.100 S GOODYEAR AUTO SERVICE CENTER #81 401 WEST 16 STREET CHEYENNE, 82001 17 7 RCRAGR08 WYD981549900 0.100 S GOODYEAR TIRE & RUBBER CO 401 W 16TH ST CHEYENNE, 82001 18 8 ST 0-005094 0.100 NW LARAMIE COUNTY DETENTION CENTER 1910 PIONEER CHEYENNE, 82001 19 9 ST 0-000941 0.100 W CHECKER-YELLOW CAB COMPANY 1808 O'NEIL AVENUE CHEYENNE, 82001 20 10 ST 0-003520 0.100 S FLACK OUTDOOR ADVERTISING, INC. 423 WEST 16TH STREET CHEYENNE, 82001 21 11 ST 0-000860 0.110 N LARAMIE COUNTY GOVERNMENT 19TH AND CAREY AVENUE CHEYENNE 22 11 LST 860 0.110 N LARAMIE COUNTY GOVERNMENT 19TH AND CAREY AVENUE CHEYENNE 23 12 ST 0-004172 0.130 S SUBURBAN PROPANE 601 WEST LINCOLNWAY CHEYENNE, 82001 24 12 LST 4172 0.130 S SUBURBAN PROPANE 601 WEST LINCOLNWAY CHEYENNE, 82001 25 SITE NAME ADDRESS www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 SUMMARY 1 REPORT SUMMARY OF LOCATABLE SITES MAP DATABASE ID# NAME SITE ID# DISTANCE FROM SITE SITE NAME 13 NLRRCRAT WYD988874673 0.130 E 14 ST 0-001124 15 ST 15 CITY, ZIP CODE PAGE # UNION PACIFIC RAILROAD 201 WEST 17TH STREET CHEYENNE, 82001 26 0.160 SW RUTLEDGE RADIATOR AND 621 WEST LINCOLNWAY WELDING CHEYENNE, 82001 28 0-001491 0.180 W AANDI MVMS 723 WEST 19TH STREET CHEYENNE, 82001 29 LST 1491 0.180 W AANDI MVMS 723 WEST 19TH STREET CHEYENNE, 82001 30 16 ST 0-005173 0.180 SW CHEYENNE NEWSPAPERS, 702 WEST LINCOLNWAY INC. CHEYENNE, 82001 31 16 LST 5173 0.180 SW CHEYENNE NEWSPAPERS, 702 WEST LINCOLNWAY INC. CHEYENNE, 82001 32 17 ST 0-005048 0.180 N PARKING LOT ROCKY MOUNTAIN FSB 2002 CAREY AVENUE CHEYENNE, 82001 33 17 LST 5048 0.180 N PARKING LOT ROCKY MOUNTAIN FSB 2002 CAREY AVENUE CHEYENNE, 82001 34 18 ST 0-000858 0.180 W HEADQUARTERS FIRE STATION 706 WEST 19TH STREET CHEYENNE, 82001 35 18 LST 858 0.180 W HEADQUARTERS FIRE STATION 706 WEST 19TH STREET CHEYENNE, 82001 36 ADDRESS 19 ST 0-003588 0.190 NE CHEYENNE MAIN 1919 CAPITOL AVENUE 3D CHEYENNE, 82001 37 19 LST 3588 0.190 NE CHEYENNE MAIN 1919 CAPITOL AVENUE 3D CHEYENNE, 82001 38 20 ST 0-000488 0.190 N FIRESTONE STORE #4855/010456 2001 CAREY AVENUE CHEYENNE, 82001 39 21 VRPBF 2053 0.190 SW 709 WEST LINCOLNWAY, CHEYENNE 709 WEST LINCOLNWAY CHEYENNE 40 22 ST 0-001079 0.200 NE DOWNTOWN CONOCO 1802 CENTRAL AVENUE CHEYENNE, 82001 41 23 ST 0-001681 0.210 W SNYDER SUBSTATION 800 WEST 18TH STREET CHEYENNE, 82001 42 23 LST 1681 0.210 W SNYDER SUBSTATION 800 WEST 18TH STREET CHEYENNE, 82001 43 24 LST 2590 0.220 SE CHEYENNE STATION 121 WEST 15TH STREET CHEYENNE, 82001 44 24 ST 0-002590 0.220 SE CHEYENNE STATION 121 WEST 15TH STREET CHEYENNE, 82001 45 24 VRPBF 2040 0.220 SE UPRR RAILROAD FACILITY 121 W 15TH ST. CHEYENNE 47 24 RCRAC WYD120371810 0.220 SE UPRR YARD (VULCAN CHEM SPILL) 121 WEST 15TH ST CHEYENNE, 82001 48 25 ST 0-002701 0.220 SE GREYHOUND LINES, INC. #8203 1503 CAPITOL AVENUE CHEYENNE, 82001 50 26 ST 0-004281 0.230 N EMERSON BUILDING EMERGENCY POWER 2001 CAPITOL AVENUE CHEYENNE, 82001 51 27 ST 0-005166 0.240 SW JERRYS TOPPERS AND CUSTOM UPHOLSTERY 803 WEST LINCOLNWAY CHEYENNE, 82001 52 www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 SUMMARY 2 REPORT SUMMARY OF LOCATABLE SITES MAP DATABASE ID# NAME SITE ID# DISTANCE FROM SITE 27 LST 5166 28 SWF 28 SITE NAME ADDRESS CITY, ZIP CODE PAGE # 0.240 SW JERRYS TOPPERS AND CUSTOM UPHOLSTERY 803 WEST LINCOLNWAY CHEYENNE, 82001 53 111 0.240 NW CHEYENNE LANDFILL (10.080) CITY ENGINEERS OFFICE, 2101 O'NEIL, CHEYENNE, 82001 54 SWF 398 0.240 NW CHEYENNE TRANSFER STATION (50.217) 2101 O''NEIL AVENUE CHEYENNE, 82001 55 29 ST 0-003980 0.250 SE UNION PACIFIC RAILROAD 105 WEST 15TH STREET CHEYENNE, 82001 56 29 LST 3980 0.250 SE UNION PACIFIC RAILROAD 105 WEST 15TH STREET CHEYENNE, 82001 57 30 ST 0-004015 0.250 W STEEL CREEK TRAILER SALES 801 WEST 19TH STREET CHEYENNE, 82001 58 30 LST 4015 0.250 W STEEL CREEK TRAILER SALES 801 WEST 19TH STREET CHEYENNE, 82001 59 31 ST 0-001492 0.250 W DAFC/MVMS 801 WEST 20TH STREET CHEYENNE, 82001 60 32 LST 179 0.260 SW BIG D #32 820 WEST LINCOLNWAY CHEYENNE, 82001 61 33 NFRAP WY0000551762 0.270 SW CHEYENNE CITY GAS CO SNYDER AVE & W 18TH ST, SE CORNER CHEYENNE, 82001 62 33 CERCLIS WY0000551762 0.270 SW CHEYENNE CITY GAS CO SNYDER AVE & W 18TH ST, SE CORNER CHEYENNE, 82001 63 34 LST 5018 0.290 E ROYAL GLASS 200 EAST 17TH CHEYENNE, 82001 64 35 LST 1366 0.310 SW FLEET MAINTENANCE DEPARTMENT 1500 SNYDER AVENUE CHEYENNE, 82001 65 36 VRPBF 2090 0.320 E HARDEE'S RESTAURANT 216 E. LINCOLNWAY CHEYENNE, 82601 66 37 VRPBF 2132 0.330 E DELUXE CLEANERS & TAILORS 1614 HOUSE AVE. CHEYENNE 67 38 LST 3475 0.330 E KUM AND GO #956 215 EAST LINCOLNWAY CHEYENNE 68 39 LST 2017 0.370 E LINCOLNWAY FAST BREAK 300 EAST LINCOLNWAY CHEYENNE, 82001 69 40 LST 1308 0.370 W SNYDER FOOD AND GAS 2100 SNYDER AVENUE CHEYENNE, 82001 70 41 LST 2232 0.380 SW E-Z AUTO SALES 1001 WEST 16TH STREET CHEYENNE, 82001 71 42 LST 4328 0.420 N BARRETT BUILDING EMERGENCY POWER 2301 CENTRAL AVENUE CHEYENNE, 82001 72 43 LST 2282 0.440 W INTERMOUNTAIN SAFETY 1122 WEST 19TH STREET CHEYENNE, 82001 73 44 LST 3368 0.450 SW MESIC'S CONOCO 1131 WEST LINCOLNWAY CHEYENNE, 82001 74 45 VRPBF 1007 0.460 E CHEYENNE VILLAGE INN 411 E. 16TH STREET CHEYENNE 75 46 LST 3978 0.500 W AMERIGAS 1000 WEST 23RD STREET CHEYENNE, 82001 76 www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 SUMMARY 3 REPORT SUMMARY OF LOCATABLE SITES MAP DATABASE ID# NAME SITE ID# DISTANCE FROM SITE 47 LST 4307 48 LST 49 SITE NAME ADDRESS CITY, ZIP CODE PAGE # 0.500 E VACANT GARAGE - 502 EAST LINCOLNWAY 502 EAST LINCOLNWAY CHEYENNE, 82001 77 276 0.500 N CHEYENNE REGIONAL MEDICAL CENTER 300 EAST 23RD STREET CHEYENNE, 82001 78 VRPBF 2029 0.500 NW 2500 BLOCK OF THOMES AVE, CHEYENNE 2500 BLOCK OF THOMES CHEYENNE 79 50 LST 527 0.500 W AMERIGAS CHEYENNE 1021 WEST 23RD STREET CHEYENNE, 82001 80 51 RCRAC WYD988870226 0.790 W GLACIER PARK PROPERTY WEST OF B.N. RR YARD 1201 W - CHEYENNE 27TH ST CHEYENNE, 82001 81 www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 SUMMARY 4 STORAGE TANKS (ST) MAP ID# 1 Distance from Property: 0.01 mi. SE SITE INFORMATION SITE ID: 0-000012 SITE NAME: MECHAM PONTIAC BUICK JEEP 1720 PIONEER AVENUE ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: SAFE SUCTION 2 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: SAFE SUCTION 3 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: OTHER TANK CAPACITY: 560 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: SAFE SUCTION www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 1 LEAKING STORAGE TANKS (LST) MAP ID# 1 Distance from Property: 0.01 mi. SE SITE INFORMATION SITE ID: 12 SITE NAME: ADDRESS: MECHAM PONTIAC BUICK JEEP 1720 PIONEER AVENUE CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 2 STORAGE TANKS (ST) MAP ID# 2 Distance from Property: 0.03 mi. NW SITE INFORMATION SITE ID: 0-003686 SITE NAME: SAM MENKIN 408 WEST 18TH ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 2 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 3 STORAGE TANKS (ST) MAP ID# 3 Distance from Property: 0.06 mi. S SITE INFORMATION SITE ID: 0-003251 SITE NAME: DINNEEN LINCOLN MERCURY 400 WEST 16TH STREET ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 01-JAN-70 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: USED OIL TANK CAPACITY: 500 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: GRAVITY FEED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 4 VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF) MAP ID# 3 Distance from Property: 0.06 mi. S SITE INFORMATION SITE NUMBER: 2139 SITE NAME: DINNEEN PROPERTY ADDRESS: 400 WEST 16TH STREET CHEYENNE, WY COUNTY: LARAMIE STATUS: OPEN VOLUNTEER: SITE TYPE: W.E. DINNEEN, INC./ DINCO LAND, INC. VRP VRP ACCEPTANCE DATE: 10/8/2010 PRELIMINARY REMEDIATION AGREEMENT DATE: 2/22/2011 REMEDY AGREEMENT DATE: NOT REPORTED LIABILITY ASSURANCE: NOT REPORTED VRP PROJECT MANAGER: CINDI MARTINEZ INSTITUTIONAL CONTROL: NO TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 5 RESOURCE CONSERVATION & RECOVERY ACT - GENERATOR FACILITIES (RCRAGR08) MAP ID# 3 Distance from Property: 0.06 mi. S FACILITY INFORMATION EPA ID#: WYD036001873 OWNER TYPE: PRIVATE NAME: DINNEEN LINCOLN MERCURY SUBARU OWNER NAME: DINNEEN W.J. ADDRESS: 400 WEST 16TH STREET OPERATOR TYPE: NOT REPORTED OPERATOR NAME: NOT REPORTED CHEYENNE, WY 82001 CONTACT NAME: JOHN DINNEEN CONTACT ADDRESS: P.O. BOX 27 CHEYENNE, WY 82003 CONTACT PHONE: 3076347733 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 04/04/1986 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 04/04/86 NAME: DINNEEN LINCOLN MERCURY SUBARU GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR ACTIVITY INFORMATION GENERATOR STATUS: SMALL QUANTITY GENERATOR SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 1993/08/19 CEI COMPLIANCE EVALUATION INSPECTION ON-SITE 1994/01/03 NRR NON-FINANCIAL RECORD REVIEW 1994/05/05 NRR NON-FINANCIAL RECORD REVIEW 1995/04/12 CEI COMPLIANCE EVALUATION INSPECTION ON-SITE 1995/04/27 NRR NON-FINANCIAL RECORD REVIEW 1998/01/26 CEI COMPLIANCE EVALUATION INSPECTION ON-SITE 1998/01/26 FUI FOLLOW-UP INSPECTION VIOLATIONS 1993/12/28 262.A GENERATORS - GENERAL www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 6 RESOURCE CONSERVATION & RECOVERY ACT - GENERATOR FACILITIES (RCRAGR08) 1993/12/28 279.C USED OIL - GENERATORS 1998/01/26 262.A GENERATORS - GENERAL 1998/01/26 262.B GENERATORS - MANIFEST 1998/01/26 279.C USED OIL - GENERATORS ENFORCEMENTS 1994/01/12 120 WRITTEN INFORMAL HAZARDOUS WASTE UNIVERSAL WASTE NO HAZARDOUS WASTE INFORMATION REPORTED - NO UNIVERSAL WASTE REPORTED - www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 7 VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF) MAP ID# 4 Distance from Property: 0.06 mi. SW SITE INFORMATION SITE NUMBER: 2056 SITE NAME: ADDRESS: FORMER WORTHAM MACHINERY CO. 517 W. 17TH STREET CHEYENNE, WY COUNTY: LARAMIE STATUS: CLOSED VOLUNTEER: SITE TYPE: DINCO LAND, INC. VRP VRP ACCEPTANCE DATE: 7/13/2005 PRELIMINARY REMEDIATION AGREEMENT DATE: 7/29/2005 REMEDY AGREEMENT DATE: NA LIABILITY ASSURANCE: NA VRP PROJECT MANAGER: NOT APPLICABLE INSTITUTIONAL CONTROL: NO TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 8 STORAGE TANKS (ST) MAP ID# 4 Distance from Property: 0.08 mi. S SITE INFORMATION SITE ID: 0-001342 SITE NAME: MORRIS A. WOLIN TRUST 522 WEST 16TH STREET ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 24-FEB-71 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 4000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 2 DATE INSTALLED: 24-FEB-71 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 4000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 3 DATE INSTALLED: 24-FEB-71 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 8000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 9 STORAGE TANKS (ST) MAP ID# 5 Distance from Property: 0.07 mi. S SITE INFORMATION SITE ID: 0-004335 SITE NAME: EAGLES AERIE # 128 1600 THOMES AVENUE ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 10 LEAKING STORAGE TANKS (LST) MAP ID# 5 Distance from Property: 0.07 mi. S SITE INFORMATION SITE ID: 4335 SITE NAME: ADDRESS: EAGLES AERIE # 128 1600 THOMES AVENUE CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 11 LEAKING STORAGE TANKS (LST) MAP ID# 6 Distance from Property: 0.10 mi. S SITE INFORMATION SITE ID: 5054 SITE NAME: GSA MOTOR POOL ADDRESS: 501 WEST LINCOLNWAY CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 12 LEAKING STORAGE TANKS (LST) MAP ID# 6 Distance from Property: 0.11 mi. S SITE INFORMATION SITE ID: 164 SITE NAME: FUEL SPECIALISTS CORPORATION ADDRESS: 519 WEST 16TH STREET P.O. BOX 445 CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: UNRESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NO PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 13 STORAGE TANKS (ST) MAP ID# 6 Distance from Property: 0.10 mi. S SITE INFORMATION SITE ID: 0-005054 SITE NAME: GSA MOTOR POOL ADDRESS: 501 WEST LINCOLNWAY CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: USED OIL TANK CAPACITY: 500 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: GRAVITY FEED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 14 STORAGE TANKS (ST) MAP ID# 6 Distance from Property: 0.11 mi. S SITE INFORMATION SITE ID: 0-000164 SITE NAME: FUEL SPECIALISTS CORPORATION 519 WEST 16TH STREET ADDRESS: P. O. BOX 445 CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 21-JUN-64 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 3000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: PRESSURIZED 2 DATE INSTALLED: 21-JUN-64 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 4000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: PRESSURIZED 3 DATE INSTALLED: 01-JAN-40 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 2000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 4 DATE INSTALLED: 01-JAN-40 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 15 RESOURCE CONSERVATION & RECOVERY ACT - GENERATOR FACILITIES (RCRAGR08) MAP ID# 6 Distance from Property: 0.11 mi. S FACILITY INFORMATION EPA ID#: WYR000212449 OWNER TYPE: NOT REPORTED NAME: HALLER'S REPAIR OWNER NAME: NOT REPORTED ADDRESS: 521 W. LINCOLNWAY OPERATOR TYPE: NOT REPORTED OPERATOR NAME: NOT REPORTED CHEYENNE, WY 82001 CONTACT NAME: NOT REPORTED CONTACT ADDRESS: , CONTACT PHONE: NOT REPORTED NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 08/06/2012 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 08/06/12 NAME: HALLER'S REPAIR GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR ACTIVITY INFORMATION GENERATOR STATUS: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 2012/08/06 CEI COMPLIANCE EVALUATION INSPECTION ON-SITE VIOLATIONS 2012/08/06 279.C USED OIL - GENERATORS ENFORCEMENTS - NO ENFORCEMENTS REPORTED HAZARDOUS WASTE UNIVERSAL WASTE NO HAZARDOUS WASTE INFORMATION REPORTED - NO UNIVERSAL WASTE REPORTED - www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 16 STORAGE TANKS (ST) MAP ID# 7 Distance from Property: 0.10 mi. S SITE INFORMATION SITE ID: 0-005047 SITE NAME: GOODYEAR AUTO SERVICE CENTER #81 401 WEST 16 STREET ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 01-JUN-86 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: USED OIL TANK CAPACITY: 550 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: GRAVITY FEED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 17 RESOURCE CONSERVATION & RECOVERY ACT - GENERATOR FACILITIES (RCRAGR08) MAP ID# 7 Distance from Property: 0.10 mi. S FACILITY INFORMATION EPA ID#: WYD981549900 OWNER TYPE: PRIVATE NAME: GOODYEAR TIRE & RUBBER CO OWNER NAME: GOODYEAR TIRE & RUBBER CO ADDRESS: 401 W 16TH ST OPERATOR TYPE: NOT REPORTED OPERATOR NAME: NOT REPORTED CHEYENNE, WY 82001 CONTACT NAME: GORDON KARDELL CONTACT ADDRESS: PO BOX 7177 PARKHILL STATION DENVER, CO 80207 CONTACT PHONE: 3033946626 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 07/14/1987 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 07/14/87 NAME: GOODYEAR TIRE & RUBBER CO GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR ACTIVITY INFORMATION GENERATOR STATUS: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 2000/06/05 CEI COMPLIANCE EVALUATION INSPECTION ON-SITE 2000/06/05 NRR NON-FINANCIAL RECORD REVIEW VIOLATIONS 2000/06/05 279.C USED OIL - GENERATORS ENFORCEMENTS - NO ENFORCEMENTS REPORTED HAZARDOUS WASTE D001 IGNITABLE WASTE UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 18 STORAGE TANKS (ST) MAP ID# 8 Distance from Property: 0.10 mi. NW SITE INFORMATION SITE ID: 0-005094 SITE NAME: LARAMIE COUNTY DETENTION CENTER 1910 PIONEER ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 01-AUG-89 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 8000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: U.S. SUCTION 2 DATE INSTALLED: 01-NOV-01 TANK STATUS: CURRENTLY IN USE SUBSTANCES: DIESEL TANK CAPACITY: 2500 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: SAFE SUCTION www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 19 STORAGE TANKS (ST) MAP ID# 9 Distance from Property: 0.10 mi. W SITE INFORMATION SITE ID: 0-000941 SITE NAME: CHECKER-YELLOW CAB COMPANY 1808 O'NEIL AVENUE ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 550 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 2 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 550 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 3 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: NOT LISTED TANK CAPACITY: 550 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 20 STORAGE TANKS (ST) MAP ID# 10 Distance from Property: 0.10 mi. S SITE INFORMATION SITE ID: 0-003520 SITE NAME: FLACK OUTDOOR ADVERTISING, INC. 423 WEST 16TH STREET ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 24-JAN-59 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 2 DATE INSTALLED: 24-JAN-59 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 3 DATE INSTALLED: 24-JAN-59 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 21 STORAGE TANKS (ST) MAP ID# 11 Distance from Property: 0.11 mi. N SITE INFORMATION SITE ID: 0-000860 SITE NAME: LARAMIE COUNTY GOVERNMENT 19TH AND CAREY AVENUE ADDRESS: CHEYENNE, WY SITE DETAILS TANK ID: 1 DATE INSTALLED: 11-APR-85 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 560 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 2 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 22 LEAKING STORAGE TANKS (LST) MAP ID# 11 Distance from Property: 0.11 mi. N SITE INFORMATION SITE ID: 860 SITE NAME: ADDRESS: LARAMIE COUNTY GOVERNMENT 19TH AND CAREY AVENUE CHEYENNE, WY SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 23 STORAGE TANKS (ST) MAP ID# 12 Distance from Property: 0.13 mi. S SITE INFORMATION SITE ID: 0-004172 SITE NAME: SUBURBAN PROPANE 601 WEST LINCOLNWAY ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 01-JAN-70 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 10000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: SAFE SUCTION www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 24 LEAKING STORAGE TANKS (LST) MAP ID# 12 Distance from Property: 0.13 mi. S SITE INFORMATION SITE ID: 4172 SITE NAME: ADDRESS: SUBURBAN PROPANE 601 WEST LINCOLNWAY CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 25 NO LONGER REGULATED RCRA NON-CORRACTS TSD FACILITIES (NLRRCRAT) MAP ID# 13 Distance from Property: 0.13 mi. E FACILITY INFORMATION EPA ID#: WYD988874673 OWNER TYPE: PRIVATE NAME: UNION PACIFIC RAILROAD OWNER NAME: UNION PACIFIC RAILROAD ADDRESS: 201 WEST 17TH STREET OPERATOR TYPE: PRIVATE OPERATOR NAME: UNION PACIFIC RAILROAD CHEYENNE, WY 82001 CONTACT NAME: GARY L HONEYMAN CONTACT ADDRESS: 15TH & CAPITOL STREET CHEYENNE, WY 82001 CONTACT PHONE: 4022331007 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 05/18/2010 CERTIFICATION CERTIFICATION NAME: CERTIFICATION TITLE: CERTIFICATION SIGNED DATE: GARY L HONEYMAN MGR ENV. SITE REMEDIATION 20100517 EDGAR R MCNUTT MGR.COMPL.MEAS. 19940327 WILLIAM L HAMMOND MANAGER 19960225 INDUSTRY CLASSIFICATION (NAICS) 482111 - LINE-HAUL RAILROADS SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 02/25/96 NAME: UNION PACIFIC RAILROAD GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 03/27/94 NAME: UPRR CHEYENNE GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 05/18/10 NAME: UPRR CHEYENNE RAILROAD FACILITY GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 07/09/93 NAME: UNION PACIFIC RAILROAD GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 26 NO LONGER REGULATED RCRA NON-CORRACTS TSD FACILITIES (NLRRCRAT) ACTIVITY INFORMATION GENERATOR STATUS: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 2012/08/30 CEI COMPLIANCE EVALUATION INSPECTION ON-SITE VIOLATIONS 2012/08/30 279.C USED OIL - GENERATORS ENFORCEMENTS - NO ENFORCEMENTS REPORTED HAZARDOUS WASTE U210 ETHENE, TETRACHLORO- D002 CORROSIVE WASTE D006 CADMIUM D009 MERCURY D010 SELENIUM UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 27 STORAGE TANKS (ST) MAP ID# 14 Distance from Property: 0.16 mi. SW SITE INFORMATION SITE ID: 0-001124 SITE NAME: RUTLEDGE RADIATOR AND WELDING 621 WEST LINCOLNWAY ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 16-APR-36 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 750 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 2 DATE INSTALLED: 16-APR-36 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 750 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 3 DATE INSTALLED: 16-APR-36 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1500 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 4 DATE INSTALLED: 16-APR-36 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1500 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 28 STORAGE TANKS (ST) MAP ID# 15 Distance from Property: 0.18 mi. W SITE INFORMATION SITE ID: 0-001491 SITE NAME: AANDI MVMS 723 WEST 19TH STREET ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 01-JAN-74 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 10000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: SAFE SUCTION 2 DATE INSTALLED: 01-JAN-74 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 10000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: SAFE SUCTION 3 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 10000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: SAFE SUCTION 4 DATE INSTALLED: 01-MAY-91 TANK STATUS: CURRENTLY IN USE SUBSTANCES: GASOLINE TANK CAPACITY: 20000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: SAFE SUCTION www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 29 LEAKING STORAGE TANKS (LST) MAP ID# 15 Distance from Property: 0.18 mi. W SITE INFORMATION SITE ID: 1491 SITE NAME: ADDRESS: AANDI MVMS 723 WEST 19TH STREET CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: 1 CONFIRMED RELEASE DATE: 06/23/91 SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 30 STORAGE TANKS (ST) MAP ID# 16 Distance from Property: 0.18 mi. SW SITE INFORMATION SITE ID: 0-005173 SITE NAME: CHEYENNE NEWSPAPERS, INC. 702 WEST LINCOLNWAY ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: NOT LISTED TANK CAPACITY: NOT REPORTED SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 31 LEAKING STORAGE TANKS (LST) MAP ID# 16 Distance from Property: 0.18 mi. SW SITE INFORMATION SITE ID: 5173 SITE NAME: ADDRESS: CHEYENNE NEWSPAPERS, INC. 702 WEST LINCOLNWAY CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 32 STORAGE TANKS (ST) MAP ID# 17 Distance from Property: 0.18 mi. N SITE INFORMATION SITE ID: 0-005048 SITE NAME: PARKING LOT ROCKY MOUNTAIN FSB 2002 CAREY AVENUE ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 01-JAN-28 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 33 LEAKING STORAGE TANKS (LST) MAP ID# 17 Distance from Property: 0.18 mi. N SITE INFORMATION SITE ID: 5048 SITE NAME: ADDRESS: PARKING LOT ROCKY MOUNTAIN FSB 2002 CAREY AVENUE CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 34 STORAGE TANKS (ST) MAP ID# 18 Distance from Property: 0.18 mi. W SITE INFORMATION SITE ID: 0-000858 SITE NAME: HEADQUARTERS FIRE STATION 706 WEST 19TH STREET ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 12-APR-79 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 2000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 2 DATE INSTALLED: 12-APR-79 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 4000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 3 DATE INSTALLED: 12-APR-79 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 6000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 4 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: USED OIL TANK CAPACITY: 500 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 5 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: OTHER TANK CAPACITY: 560 SPECIFICATION DESCRIPTION: FIBERGLASS REINFORCED PLASTIC - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 35 LEAKING STORAGE TANKS (LST) MAP ID# 18 Distance from Property: 0.18 mi. W SITE INFORMATION SITE ID: 858 SITE NAME: ADDRESS: HEADQUARTERS FIRE STATION 706 WEST 19TH STREET CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 36 STORAGE TANKS (ST) MAP ID# 19 Distance from Property: 0.19 mi. NE SITE INFORMATION SITE ID: 0-003588 SITE NAME: CHEYENNE MAIN 1919 CAPITOL AVENUE 3D ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 30-JUN-69 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 3000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 2 DATE INSTALLED: 01-JAN-50 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: NOT LISTED TANK CAPACITY: 750 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 37 LEAKING STORAGE TANKS (LST) MAP ID# 19 Distance from Property: 0.19 mi. NE SITE INFORMATION SITE ID: 3588 SITE NAME: ADDRESS: CHEYENNE MAIN 1919 CAPITOL AVENUE 3D CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 38 STORAGE TANKS (ST) MAP ID# 20 Distance from Property: 0.19 mi. N SITE INFORMATION SITE ID: 0-000488 SITE NAME: FIRESTONE STORE #4855/010456 2001 CAREY AVENUE ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 01-JAN-79 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: USED OIL TANK CAPACITY: 560 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 39 VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF) MAP ID# 21 Distance from Property: 0.19 mi. SW SITE INFORMATION SITE NUMBER: 2053 SITE NAME: ADDRESS: 709 WEST LINCOLNWAY, CHEYENNE 709 WEST LINCOLNWAY CHEYENNE, WY COUNTY: LARAMIE STATUS: OPEN VOLUNTEER: SITE TYPE: MECHANICAL SYSTEMS VRP VRP ACCEPTANCE DATE: 6/16/2005 PRELIMINARY REMEDIATION AGREEMENT DATE: NA REMEDY AGREEMENT DATE: 6/18/2007 LIABILITY ASSURANCE: 6/18/2007 VRP PROJECT MANAGER: CINDI MARTINEZ INSTITUTIONAL CONTROL: NO TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 40 STORAGE TANKS (ST) MAP ID# 22 Distance from Property: 0.20 mi. NE SITE INFORMATION SITE ID: 0-001079 SITE NAME: DOWNTOWN CONOCO 1802 CENTRAL AVENUE ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 01-JAN-85 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 2000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: SAFE SUCTION 2 DATE INSTALLED: 01-JAN-85 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 2000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: SAFE SUCTION 3 DATE INSTALLED: 01-JAN-77 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 6000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: SAFE SUCTION 4 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: USED OIL TANK CAPACITY: 500 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: SAFE SUCTION www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 41 STORAGE TANKS (ST) MAP ID# 23 Distance from Property: 0.21 mi. W SITE INFORMATION SITE ID: 0-001681 SITE NAME: SNYDER SUBSTATION 800 WEST 18TH STREET ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 26-JUN-65 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 20000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: SAFE SUCTION www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 42 LEAKING STORAGE TANKS (LST) MAP ID# 23 Distance from Property: 0.21 mi. W SITE INFORMATION SITE ID: 1681 SITE NAME: ADDRESS: SNYDER SUBSTATION 800 WEST 18TH STREET CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 43 LEAKING STORAGE TANKS (LST) MAP ID# 24 Distance from Property: 0.22 mi. SE SITE INFORMATION SITE ID: 2590 SITE NAME: CHEYENNE STATION ADDRESS: 121 WEST 15TH STREET CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 44 STORAGE TANKS (ST) MAP ID# 24 Distance from Property: 0.22 mi. SE SITE INFORMATION SITE ID: 0-002590 SITE NAME: CHEYENNE STATION ADDRESS: 121 WEST 15TH STREET CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: USED OIL TANK CAPACITY: 20000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 2 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 500 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 3 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 500 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 4 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 20000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 5 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: USED OIL TANK CAPACITY: 500 SPECIFICATION DESCRIPTION: FIBERGLASS REINFORCED PLASTIC - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 45 STORAGE TANKS (ST) TANK ID: 6 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: USED OIL TANK CAPACITY: 500 SPECIFICATION DESCRIPTION: FIBERGLASS REINFORCED PLASTIC - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 46 VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF) MAP ID# 24 Distance from Property: 0.22 mi. SE SITE INFORMATION SITE NUMBER: 2040 SITE NAME: ADDRESS: UPRR RAILROAD FACILITY 121 W 15TH ST. CHEYENNE, WY COUNTY: LARAMIE STATUS: OPEN VOLUNTEER: SITE TYPE: UNION PACIFIC RAILROAD VRP VRP ACCEPTANCE DATE: 1/7/2004 PRELIMINARY REMEDIATION AGREEMENT DATE: 6/1/2004 REMEDY AGREEMENT DATE: NOT REPORTED LIABILITY ASSURANCE: NOT REPORTED VRP PROJECT MANAGER: CINDI MARTINEZ INSTITUTIONAL CONTROL: NO TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 47 RESOURCE CONSERVATION & RECOVERY ACT - CORRECTIVE ACTION FACILITIES (RCRAC) MAP ID# 24 Distance from Property: 0.22 mi. SE FACILITY INFORMATION EPA ID#: WYD120371810 OWNER TYPE: NOT REPORTED NAME: UPRR YARD (VULCAN CHEM SPILL) OWNER NAME: NOT REPORTED ADDRESS: 121 WEST 15TH ST OPERATOR TYPE: PRIVATE OPERATOR NAME: UPRR VULCAN CHEMICAL SPILL CHEYENNE, WY 82001 CONTACT NAME: TOM PARROTT CONTACT ADDRESS: PO BOX 7689 BIRMINGHAM, AL 35253 CONTACT PHONE: 2058773851 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 07/14/2006 INDUSTRY CLASSIFICATION (NAICS) 211112 - NATURAL GAS LIQUID EXTRACTION 482111 - LINE-HAUL RAILROADS 48821 - SUPPORT ACTIVITIES FOR RAIL TRANSPORTATION SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 02/16/00 NAME: UNION PACIFIC RAILROAD YARD GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 02/28/92 NAME: UNION PACIFIC RAILROAD YARD GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 03/15/90 NAME: UNION PACIFIC RAILROAD YARD GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 03/27/96 NAME: UNION PACIFIC RAILROAD YARD GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 07/14/06 NAME: UPRR YARD (VULCAN CHEM SPILL) GENERATOR CLASSIFICATION: NOT A GENERATOR DATE RECEIVED BY AGENCY: 08/04/89 NAME: UPRR YARD (VULCAN CHEM SPILL) GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 48 RESOURCE CONSERVATION & RECOVERY ACT - CORRECTIVE ACTION FACILITIES (RCRAC) ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: YES IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 2002/01/17 CEI COMPLIANCE EVALUATION INSPECTION ON-SITE 2006/02/13 OAM OPERATION AND MAINTENANCE INSPECTION VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED HAZARDOUS WASTE F003 THE FOLLOWING SPENT NON-HALOGENATED SOLVENTS: XYLENE, ACETONE, ETHYL ACETATE, ETHYL BENZENE, ETHYL ETHER, METHYL ISOBUTYL KETONE, N-BUTYL ALCOHOL, CYCLOHEXANONE, AND METHANOL; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONLY THE ABOVE SPENT NONHALOGENATED SOLVENTS; AND ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONE OR MORE OF THE ABOVE NONHALOGENATED SOLVENTS, AND A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THOSE SOLVENTS LISTED IN F001, F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. U210 ETHENE, TETRACHLORO- UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA SPILL SITE ON UPRR YARD YES YES NO ----- CORRECTIVE ACTION EVENT CA110 19990922 INVESTIGATION WORKPLAN RECEIVED CA150 19991105 INVESTIGATION WORKPLAN APPROVED CA190 20000830 INVESTIGATION REPORT RECEIVED CA260 20000830 CMS WORKPLAN RECEIVED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 49 STORAGE TANKS (ST) MAP ID# 25 Distance from Property: 0.22 mi. SE SITE INFORMATION SITE ID: 0-002701 SITE NAME: GREYHOUND LINES, INC. #8203 1503 CAPITOL AVENUE ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 01-JAN-84 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 10000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: PRESSURIZED 2 DATE INSTALLED: 01-JAN-84 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 10000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: PRESSURIZED 3 DATE INSTALLED: 16-JUN-71 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 12000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 50 STORAGE TANKS (ST) MAP ID# 26 Distance from Property: 0.23 mi. N SITE INFORMATION SITE ID: 0-004281 SITE NAME: EMERSON BUILDING EMERGENCY POWER 2001 CAPITOL AVENUE ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 01-FEB-82 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 2 DATE INSTALLED: 13-OCT-00 TANK STATUS: CURRENTLY IN USE SUBSTANCES: DIESEL TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: SAFE SUCTION www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 51 STORAGE TANKS (ST) MAP ID# 27 Distance from Property: 0.24 mi. SW SITE INFORMATION SITE ID: 0-005166 SITE NAME: JERRYS TOPPERS AND CUSTOM UPHOLSTERY 803 WEST LINCOLNWAY ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: NOT LISTED TANK CAPACITY: NOT REPORTED SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 52 LEAKING STORAGE TANKS (LST) MAP ID# 27 Distance from Property: 0.24 mi. SW SITE INFORMATION SITE ID: 5166 SITE NAME: ADDRESS: JERRYS TOPPERS AND CUSTOM UPHOLSTERY 803 WEST LINCOLNWAY CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: UNRESOLVED CONTAMINATED SITE CORRECTIVE ACTION: Yes PRIORITY RANKING: 435 www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 53 PERMITTED SOLID WASTE FACILITIES (SWF) MAP ID# 28 Distance from Property: 0.24 mi. NW SITE INFORMATION SITE ID: 111 SITE NAME: ADDRESS: CHEYENNE LANDFILL (10.080) CITY ENGINEERS OFFICE, 2101 O'NEIL, ROOM 202 CHEYENNE, WY 82001 OWNER: CHEYENNE (CITY OF) SITE DETAILS FACILITY STATUS: ACTIVE FACILITY TYPE: TYPE I MUNICIPAL USED OIL ACCEPTED: F WASTE TYPE: CONSTRUCTION/DEMOLITION WASTE TYPE: MUNICIPAL SW WASTE TYPE: PETROLEUM CONTAMINATED SOILS WASTE TYPE: SCRAP TIRES WASTE TYPE: DEAD ANIMALS WASTE TYPE: USED OIL WASTE TYPE: SUMP WASTE (NON-HAZARDOUS) www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 54 PERMITTED SOLID WASTE FACILITIES (SWF) MAP ID# 28 Distance from Property: 0.24 mi. NW SITE INFORMATION SITE ID: 398 SITE NAME: ADDRESS: CHEYENNE TRANSFER STATION (50.217) 2101 O''NEIL AVENUE CHEYENNE, WY 82001 OWNER: CHEYENNE (CITY OF) SITE DETAILS FACILITY STATUS: ACTIVE FACILITY TYPE: SW TSD USED OIL ACCEPTED: F WASTE TYPE: HOUSEHOLD HAZARDOUS WASTE WASTE TYPE: USED OIL WASTE TYPE: CESQG www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 55 STORAGE TANKS (ST) MAP ID# 29 Distance from Property: 0.25 mi. SE SITE INFORMATION SITE ID: 0-003980 SITE NAME: UNION PACIFIC RAILROAD 105 WEST 15TH STREET ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 500 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 2 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 10000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: NOT LISTED 3 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 500 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: NOT LISTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 56 LEAKING STORAGE TANKS (LST) MAP ID# 29 Distance from Property: 0.25 mi. SE SITE INFORMATION SITE ID: 3980 SITE NAME: ADDRESS: UNION PACIFIC RAILROAD 105 WEST 15TH STREET CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 57 STORAGE TANKS (ST) MAP ID# 30 Distance from Property: 0.25 mi. W SITE INFORMATION SITE ID: 0-004015 SITE NAME: STEEL CREEK TRAILER SALES 801 WEST 19TH STREET ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: KEROSENE TANK CAPACITY: 1000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: SAFE SUCTION 2 DATE INSTALLED: NOT REPORTED TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 2000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: SAFE SUCTION www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 58 LEAKING STORAGE TANKS (LST) MAP ID# 30 Distance from Property: 0.25 mi. W SITE INFORMATION SITE ID: 4015 SITE NAME: ADDRESS: STEEL CREEK TRAILER SALES 801 WEST 19TH STREET CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 59 STORAGE TANKS (ST) MAP ID# 31 Distance from Property: 0.25 mi. W SITE INFORMATION SITE ID: 0-001492 SITE NAME: DAFC/MVMS 801 WEST 20TH STREET ADDRESS: CHEYENNE, WY 82001 SITE DETAILS TANK ID: 1 DATE INSTALLED: 01-JAN-74 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 10000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: TANK ID: SAFE SUCTION 2 DATE INSTALLED: 01-JAN-74 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: GASOLINE TANK CAPACITY: 10000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: SAFE SUCTION www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 60 LEAKING STORAGE TANKS (LST) MAP ID# 32 Distance from Property: 0.26 mi. SW SITE INFORMATION SITE ID: 179 SITE NAME: ADDRESS: BIG D #32 820 WEST LINCOLNWAY CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: 9 CONFIRMED RELEASE DATE: 03/16/98 SITE TYPE: UNRESOLVED CONTAMINATED SITE CORRECTIVE ACTION: Yes PRIORITY RANKING: 843 www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 61 NO FURTHER REMEDIAL ACTION PLANNED SITES (NFRAP) MAP ID# 33 Distance from Property: 0.27 mi. SW FACILITY INFORMATION EPA ID#: WY0000551762 SITE ID#: 0801457 NAME: CHEYENNE CITY GAS CO ADDRESS: SNYDER AVE & W 18TH ST, SE CORNER CHEYENNE, WY 82001 COUNTY: LARAMIE ACTION START DATE COMPLETION DATE RESPONSIBILITY DS - DISCOVERY NOT REPORTED 12/15/1993 EPA FUND PA - PRELIMINARY ASSESSMENT NOT REPORTED 11/14/1994 EPA FUND SI - SITE INSPECTION NOT REPORTED 9/25/1997 00:00:00 EPA FUND VS - ARCHIVE SITE NOT REPORTED 11/20/2001 EPA IN-HOUSE ACTION DESCRIPTIONS DS - (DISCOVERY) - THE PROCESS BY WHICH A POTENTIAL HAZARDOUS WASTE SITE IS BROUGHT TO THE ATTENTION OF THE EPA. THE PROCESS CAN OCCUR THROUGH THE USE OF SEVERAL MECHANISMS SUCH AS A PHONE CALL OR REFERRAL BY ANOTHER GOVERNMENT AGENCY. PA - (PRELIMINARY ASSESSMENT) - COLLECTION OF DIVERSE EXISTING INFORMATION ABOUT THE SOURCE AND NATURE OF THE SITE HAZARD. IT IS EPA POLICY TO COMPLETE THE PRELIMINARY ASSESSMENT WITHIN ONE YEAR OF SITE DISCOVERY. SI - (SITE INSPECTION) - THE PROCESS OF COLLECTING SITE DATA AND SAMPLES TO CHARACTERIZE THE SEVERITY OF THE HAZARD FOR THE HAZARD RANKING SCORE AND/OR ENFORCEMENT SUPPORT. VS - (ARCHIVE SITE) - THE DECISION IS MADE THAT NO FURTHER ACTIVITY IS PLANNED AT THE SITE. www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 62 COMPREHENSIVE ENVIRONMENTAL RESPONSE, COMPENSATION & LIABILITY INFORMATION SYSTEM (CERCLIS) MAP ID# 33 Distance from Property: 0.27 mi. SW FACILITY INFORMATION EPA ID#: WY0000551762 SITE ID#: 0801457 NAME: CHEYENNE CITY GAS CO ADDRESS: SNYDER AVE & W 18TH ST, SE CORNER CHEYENNE, WY 82001 COUNTY: LARAMIE NATIONAL PRIORITY LISTING: N - NOT ON THE NPL FEDERAL FACILITY CLASSIFICATION: N - NOT A FEDERAL FACILITY NON-NPL STATUS: NF - NFRAP PHYSICAL CLASSIFICATION OF SITE / INCIDENT: ABANDONED SITE DESCRIPTION - NO SITE DESCRIPTION INFORMATION AVAILABLE SITE HISTORY - NO SITE HISTORY INFORMATION AVAILABLE ACTIONS TYPE: DS - DISCOVERY START DATE: NR COMPLETION DATE: 12/15/1993 ACTION TYPE DEFINITION: THE PROCESS BY WHICH A POTENTIAL HAZARDOUS WASTE SITE IS BROUGHT TO THE ATTENTION OF THE EPA. THE PROCESS CAN OCCUR THROUGH THE USE OF SEVERAL MECHANISMS SUCH AS A PHONE CALL OR REFERRAL BY ANOTHER GOVERNMENT AGENCY. TYPE: PA - PRELIMINARY ASSESSMENT START DATE: NR COMPLETION DATE: 11/14/1994 ACTION TYPE DEFINITION: COLLECTION OF DIVERSE EXISTING INFORMATION ABOUT THE SOURCE AND NATURE OF THE SITE HAZARD. IT IS EPA POLICY TO COMPLETE THE PRELIMINARY ASSESSMENT WITHIN ONE YEAR OF SITE DISCOVERY. TYPE: SI - SITE INSPECTION START DATE: NR COMPLETION DATE: 09/25/1997 ACTION TYPE DEFINITION: THE PROCESS OF COLLECTING SITE DATA AND SAMPLES TO CHARACTERIZE THE SEVERITY OF THE HAZARD FOR THE HAZARD RANKING SCORE AND/OR ENFORCEMENT SUPPORT. TYPE: VS - ARCHIVE SITE START DATE: NR COMPLETION DATE: 11/20/2001 ACTION TYPE DEFINITION: THE DECISION IS MADE THAT NO FURTHER ACTIVITY IS PLANNED AT THE SITE. CONTAMINANTS - NO CONTAMINATION INFORMATION AVAILABLE LISTING OF PUBLISHED INSTITUTIONAL CONTROL SITE REPORT - NOT AN INSTITUTIONAL CONTROL SITE - www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 63 LEAKING STORAGE TANKS (LST) MAP ID# 34 Distance from Property: 0.29 mi. E SITE INFORMATION SITE ID: 5018 SITE NAME: ADDRESS: ROYAL GLASS 200 EAST 17TH CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 64 LEAKING STORAGE TANKS (LST) MAP ID# 35 Distance from Property: 0.31 mi. SW SITE INFORMATION SITE ID: 1366 SITE NAME: ADDRESS: FLEET MAINTENANCE DEPARTMENT 1500 SNYDER AVENUE CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: 3 CONFIRMED RELEASE DATE: 05/17/91 SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NO PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 65 VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF) MAP ID# 36 Distance from Property: 0.32 mi. E SITE INFORMATION SITE NUMBER: 2090 SITE NAME: ADDRESS: HARDEE'S RESTAURANT 216 E. LINCOLNWAY CHEYENNE, WY 82601 COUNTY: LARAMIE STATUS: CLOSED VOLUNTEER: SITE TYPE: BIG SKY LAND COMPANY LLC VRP VRP ACCEPTANCE DATE: 10/23/2006 PRELIMINARY REMEDIATION AGREEMENT DATE: 7/5/2007 REMEDY AGREEMENT DATE: NA LIABILITY ASSURANCE: NA VRP PROJECT MANAGER: NOT APPLICABLE INSTITUTIONAL CONTROL: NO TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 66 VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF) MAP ID# 37 Distance from Property: 0.33 mi. E SITE INFORMATION SITE NUMBER: 2132 SITE NAME: ADDRESS: DELUXE CLEANERS & TAILORS 1614 HOUSE AVE. CHEYENNE, WY COUNTY: LARAMIE STATUS: OPEN VOLUNTEER: SITE TYPE: BASH, INC. VRP VRP ACCEPTANCE DATE: 9/25/2009 PRELIMINARY REMEDIATION AGREEMENT DATE: 11/29/2010 REMEDY AGREEMENT DATE: NOT REPORTED LIABILITY ASSURANCE: NOT REPORTED VRP PROJECT MANAGER: NOT APPLICABLE INSTITUTIONAL CONTROL: NO TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 67 LEAKING STORAGE TANKS (LST) MAP ID# 38 Distance from Property: 0.33 mi. E SITE INFORMATION SITE ID: 3475 SITE NAME: KUM AND GO #956 ADDRESS: 215 EAST LINCOLNWAY CHEYENNE, WY SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: UNRESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 68 LEAKING STORAGE TANKS (LST) MAP ID# 39 Distance from Property: 0.37 mi. E SITE INFORMATION SITE ID: 2017 SITE NAME: ADDRESS: LINCOLNWAY FAST BREAK 300 EAST LINCOLNWAY CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: 2 CONFIRMED RELEASE DATE: 04/04/97 SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 69 LEAKING STORAGE TANKS (LST) MAP ID# 40 Distance from Property: 0.37 mi. W SITE INFORMATION SITE ID: 1308 SITE NAME: ADDRESS: SNYDER FOOD AND GAS 2100 SNYDER AVENUE CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: 2 CONFIRMED RELEASE DATE: 02/01/99 SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 70 LEAKING STORAGE TANKS (LST) MAP ID# 41 Distance from Property: 0.38 mi. SW SITE INFORMATION SITE ID: 2232 SITE NAME: ADDRESS: E-Z AUTO SALES 1001 WEST 16TH STREET CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 71 LEAKING STORAGE TANKS (LST) MAP ID# 42 Distance from Property: 0.42 mi. N SITE INFORMATION SITE ID: 4328 SITE NAME: ADDRESS: BARRETT BUILDING EMERGENCY POWER 2301 CENTRAL AVENUE CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: UNRESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 72 LEAKING STORAGE TANKS (LST) MAP ID# 43 Distance from Property: 0.44 mi. W SITE INFORMATION SITE ID: 2282 SITE NAME: ADDRESS: INTERMOUNTAIN SAFETY 1122 WEST 19TH STREET CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: UNRESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NO PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 73 LEAKING STORAGE TANKS (LST) MAP ID# 44 Distance from Property: 0.45 mi. SW SITE INFORMATION SITE ID: 3368 SITE NAME: ADDRESS: MESIC'S CONOCO 1131 WEST LINCOLNWAY CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 74 VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF) MAP ID# 45 Distance from Property: 0.46 mi. E SITE INFORMATION SITE NUMBER: 1007 SITE NAME: ADDRESS: CHEYENNE VILLAGE INN 411 E. 16TH STREET CHEYENNE, WY COUNTY: LARAMIE STATUS: CLOSED VOLUNTEER: SITE TYPE: GULLEY ENTERPRISES VRP/ICP VRP ACCEPTANCE DATE: 4/26/2001 PRELIMINARY REMEDIATION AGREEMENT DATE: 5/29/2001 conditional REMEDY AGREEMENT DATE: NA LIABILITY ASSURANCE: NA VRP PROJECT MANAGER: NOT APPLICABLE INSTITUTIONAL CONTROL: NO TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 75 LEAKING STORAGE TANKS (LST) MAP ID# 46 Distance from Property: 0.50 mi. W SITE INFORMATION SITE ID: 3978 SITE NAME: ADDRESS: AMERIGAS 1000 WEST 23RD STREET CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 76 LEAKING STORAGE TANKS (LST) MAP ID# 47 Distance from Property: 0.50 mi. E SITE INFORMATION SITE ID: 4307 SITE NAME: ADDRESS: VACANT GARAGE - 502 EAST LINCOLNWAY 502 EAST LINCOLNWAY CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: UNRESOLVED CONTAMINATED SITE CORRECTIVE ACTION: Yes PRIORITY RANKING: 759 www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 77 LEAKING STORAGE TANKS (LST) MAP ID# 48 Distance from Property: 0.50 mi. N SITE INFORMATION SITE ID: 276 SITE NAME: ADDRESS: CHEYENNE REGIONAL MEDICAL CENTER 300 EAST 23RD STREET CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: 2 CONFIRMED RELEASE DATE: 01/01/87 SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 78 VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF) MAP ID# 49 Distance from Property: 0.50 mi. NW SITE INFORMATION SITE NUMBER: 2029 SITE NAME: ADDRESS: 2500 BLOCK OF THOMES AVE, CHEYENNE 2500 BLOCK OF THOMES CHEYENNE, WY COUNTY: LARAMIE STATUS: OPEN VOLUNTEER: SITE TYPE: STATE OF WY, A & I CONSTRUCTION (FORMERLY SAFEWAY INC.) VRP VRP ACCEPTANCE DATE: 6/2/2003 PRELIMINARY REMEDIATION AGREEMENT DATE: NOT REPORTED REMEDY AGREEMENT DATE: NOT REPORTED LIABILITY ASSURANCE: NOT REPORTED VRP PROJECT MANAGER: AL THOMPSON INSTITUTIONAL CONTROL: NO TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 79 LEAKING STORAGE TANKS (LST) MAP ID# 50 Distance from Property: 0.50 mi. W SITE INFORMATION SITE ID: 527 SITE NAME: ADDRESS: AMERIGAS CHEYENNE 1021 WEST 23RD STREET CHEYENNE, WY 82001 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 80 RESOURCE CONSERVATION & RECOVERY ACT - CORRECTIVE ACTION FACILITIES (RCRAC) MAP ID# 51 Distance from Property: 0.79 mi. W FACILITY INFORMATION EPA ID#: WYD988870226 OWNER TYPE: NOT REPORTED NAME: GLACIER PARK PROPERTY - CHEYENNE OWNER NAME: NOT REPORTED ADDRESS: WEST OF B.N. RR YARD 1201 W 27TH ST. OPERATOR TYPE: NOT REPORTED OPERATOR NAME: NOT REPORTED CHEYENNE, WY 82001 CONTACT NAME: NOT REPORTED CONTACT ADDRESS: , CONTACT PHONE: NOT REPORTED NON-NOTIFIER: NON-NOTIFIER DATE RECEIVED BY AGENCY: 09/09/1991 INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 09/09/91 NAME: GLACIER PARK PROPERTY - CHEYENNE GENERATOR CLASSIFICATION: NOT A GENERATOR ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: YES CORRECTIVE ACTION WORKLOAD UNIVERSE: YES IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 1991/07/15 NRR NON-FINANCIAL RECORD REVIEW 1991/09/09 FUI FOLLOW-UP INSPECTION VIOLATIONS 1991/07/15 264.N TSD - LANDFILL STANDARDS ENFORCEMENTS 1991/09/10 320 FINAL IMMINENT HAZARD ORDER HAZARDOUS WASTE UNIVERSAL WASTE NO HAZARDOUS WASTE INFORMATION REPORTED - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA ENTIRE FACILITY ----- ----- YES ----- www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 81 RESOURCE CONSERVATION & RECOVERY ACT - CORRECTIVE ACTION FACILITIES (RCRAC) CORRECTIVE ACTION EVENT CA100 19910910 INVESTIGATION IMPOSITION www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 82 REPORT SUMMARY OF UNLOCATABLE SITES DATABASE TYPE SITE ID# SITE NAME ADDRESS CITY ZIP CODE LST 3056 CNF TRANSPORTATION P. O. BOX 2067 CHEYENNE 82009 ST 0-001115 MARVIN BERRY P. O. BOX 167 CHEYENNE 82009 MERIDEN ROUTE www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 1 LEAKING STORAGE TANKS (LST) SITE INFORMATION SITE ID: 3056 SITE NAME: ADDRESS: CNF TRANSPORTATION P. O. BOX 2067 CHEYENNE, WY 82009 SITE DETAILS TOTAL ACTIVE: NOT REPORTED CONFIRMED RELEASE DATE: NOT REPORTED SITE TYPE: RESOLVED CONTAMINATED SITE CORRECTIVE ACTION: NOT REPORTED PRIORITY RANKING: NOT REPORTED www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 1 STORAGE TANKS (ST) SITE INFORMATION SITE ID: 0-001115 SITE NAME: MARVIN BERRY P. O. BOX 167 ADDRESS: MERIDEN ROUTE CHEYENNE, WY 82009 SITE DETAILS TANK ID: 1 DATE INSTALLED: 01-JUL-79 TANK STATUS: PERMANENTLY OUT OF USE SUBSTANCES: DIESEL TANK CAPACITY: 3000 SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION PUMP TYPE DESCRIPTION: SAFE SUCTION www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 2 ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL AIRSAFS Aerometric Information Retrieval System / Air Facility Subsystem VERSION DATE: 8/2012 The United States Environmental Protection Agency (EPA) modified the Aerometric Information Retrieval System (AIRS) to a database that exclusively tracks the compliance of stationary sources of air pollution with EPA regulations: the Air Facility Subsystem (AFS). Since this change in 2001, the management of the AIRS/AFS database was assigned to EPA's Office of Enforcement and Compliance Assurance. Brownfields Management System BF VERSION DATE: 4/2013 Brownfields are real property, the expansion, redevelopment, or reuse of which may be complicated by the presence or potential presence of a hazardous substance, pollutant, or contaminant. Cleaning up and reinvesting in these properties takes development pressures off of undeveloped, open land, and both improves and protects the environment. The United States Environmental Protection Agency maintains this database to track activities in the various brown field grant programs including grantee assessment, site cleanup and site redevelopment. BRS Biennial Reporting System VERSION DATE: 12/2009 The United States Environmental Protection Agency (EPA), in cooperation with the States, biennially collects information regarding the generation, management, and final disposition of hazardous wastes regulated under the Resource Conservation and Recovery Act of 1976 (RCRA), as amended. The Biennial Report captures detailed data on the generation of hazardous waste from large quantity generators and data on waste management practices from treatment, storage and disposal facilities. Currently, the EPA states that data collected between 1991 and 1997 was originally a part of the defunct Biennial Reporting System and is now incorporated into the RCRAInfo data system. CDL Clandestine Drug Laboratory Locations VERSION DATE: 3/2012 The U.S. Department of Justice ("the Department") provides this information as a public service. It contains addresses of some locations where law enforcement agencies reported they found chemicals or other items that indicated the presence of either clandestine drug laboratories or dumpsites. In most cases, the source of the entries is not the Department, and the Department has not verified the entry and does not guarantee its accuracy. Members of the public must verify the accuracy of all entries by, for example, contacting local law enforcement and local health departments. The Department does not establish, implement, enforce, or certify compliance with clean-up or remediation standards for contaminated sites; the public should contact a state or local health department or environmental protection agency for that information. www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DEFINITIONS 1 ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL CERCLIS Comprehensive Environmental Response, Compensation & Liability Information System VERSION DATE: 12/2012 CERCLIS is the repository for site and non-site specific Superfund information in support of the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA). This United States Environmental Protection Agency database contains an extract of sites that have been investigated or are in the process of being investigated for potential environmental risk. DNPL Delisted National Priorities List VERSION DATE: 12/2012 This database includes sites from the United States Environmental Protection Agency’s Final National Priorties List (NPL) where remedies have proven to be satisfactory or sites where the original analyses were inaccurate, and the site is no longer appropriate for inclusion on the NPL, and final publication in the Federal Register has occurred. DOCKETS EPA Docket Data VERSION DATE: 12/2005 The United States Environmental Protection Agency Docket data lists Civil Case Defendants, filing dates as far back as 1971, laws broken including section, violations that occurred, pollutants involved, penalties assessed and superfund awards by facility and location. Please refer to ICIS database as source of current data. DOD Department of Defense Sites VERSION DATE: 12/2005 This information originates from the National Atlas of the United States Federal Lands data, which includes lands owned or administered by the Federal government. Army DOD, Army Corps of Engineers DOD, Air Force DOD, Navy DOD and Marine DOD areas of 640 acres or more are included. Federal Engineering Institutional Control Sites EC VERSION DATE: 4/2013 This database includes site locations where Engineering and/or Institutional Controls have been identified as part of a selected remedy for the site as defined by United States Environmental Protection Agency official remedy decision documents. A site listing does not indicate that the institutional and engineering controls are currently in place nor will be in place once the remedy is complete; it only indicates that the decision to include either of them in the remedy is documented as of the completed date of the document. Institutional controls are actions, such as legal controls, that help minimize the potential for human exposure to contamination by ensuring appropriate land or resource use. Engineering controls include caps, barriers, or other device engineering to prevent access, exposure, or continued migration of contamination. www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DEFINITIONS 2 ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL ERNSWY Emergency Response Notification System VERSION DATE: 12/2012 This National Response Center database contains data on reported releases of oil, chemical, radiological, biological, and/or etiological discharges into the environment anywhere in the United States and its territories. The data comes from spill reports made to the U.S. Environmental Protection Agency, U.S. Coast Guard, the National Response Center and/or the U.S. Department of Transportation. FRSWY Facility Registry System VERSION DATE: 11/2012 The United States Environmental Protection Agency's Office of Environmental Information (OEI) developed the Facility Registry System (FRS) as the centrally managed database that identifies facilities, sites or places subject to environmental regulations or of environmental interest. The Facility Registry System replaced the Facility Index System or FINDS database. FUDS Formerly Used Defense Sites VERSION DATE: 2/2013 The 2011 FUDS inventory includes properties previously owned by or leased to the United States and under Secretary of Defense jurisdiction. The remediation of these properties is the responsibility of the Department of Defense. HISTPST Historical Gas Stations VERSION DATE: 7/1930 This historic directory of service stations is provided by the Cities Service Company. The directory includes Cities Service filling stations that were located throughout the United States in 1930. HMIRSR08 Hazardous Materials Incident Reporting System VERSION DATE: 1/2013 The HMIRS database contains unintentional hazardous materials release information reported to the U.S. Department of Transportation located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. ICIS Integrated Compliance Information System (formerly DOCKETS) VERSION DATE: 8/2012 ICIS is a case activity tracking and management system for civil, judicial, and administrative federal Environmental Protection Agency enforcement cases. ICIS contains information on federal administrative and federal judicial cases under the following environmental statutes: the Clean Air Act, the Clean Water Act, the Resource Conservation and Recovery Act, the Emergency Planning www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DEFINITIONS 3 ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL and Community Right-to-Know Act - Section 313, the Toxic Substances Control Act, the Federal Insecticide, Fungicide, and Rodenticide Act, the Comprehensive Environmental Response, Compensation, and Liability Act, the Safe Drinking Water Act, and the Marine Protection, Research, and Sanctuaries Act. ICISNPDES VERSION DATE: 8/2012 Integrated Compliance Information System National Pollutant Discharge Elimination System In 2006, the Integrated Compliance Information System (ICIS) - National Pollutant Discharge Elimination System (NPDES) became the NPDES national system of record for select states, tribes and territories. ICIS-NPDES is an information management system maintained by the United States Environmental Protection Agency's Office of Compliance to track permit compliance and enforcement status of facilities regulated by the NPDES under the Clean Water Act. ICIS-NPDES is designed to support the NPDES program at the state, regional, and national levels. LUCIS Land Use Control Information System VERSION DATE: 9/2006 The LUCIS database is maintained by the U.S. Navy and contains information for former Base Realignment and Closure (BRAC) properties across the United States. MLTS Material Licensing Tracking System VERSION DATE: 1/2013 MLTS is a list of approximately 8,100 sites which have or use radioactive materials subject to the United States Nuclear Regulatory Commission (NRC) licensing requirements. NFRAP No Further Remedial Action Planned Sites VERSION DATE: 12/2012 This database includes sites which have been determined by the United States Environmental Protection Agency, following preliminary assessment, to no longer pose a significant risk or require further activity under CERCLA. After initial investigation, no contamination was found, contamination was quickly removed or contamination was not serious enough to require Federal Superfund action or NPL consideration. NLRRCRAC No Longer Regulated RCRA Corrective Action Facilities VERSION DATE: 3/2013 This database includes RCRA Corrective Action facilities that are no longer regulated by the United States Environmental Protection Agency or do not meet other RCRA reporting requirements. www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DEFINITIONS 4 ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL NLRRCRAG No Longer Regulated RCRA Generator Facilities VERSION DATE: 3/2013 This database includes RCRA Generator facilities that are no longer regulated by the United States Environmental Protection Agency or do not meet other RCRA reporting requirements. This listing includes facilities that formerly generated hazardous waste. Large Quantity Generators: Generate 1,000 kg or more of hazardous waste during any calendar month; or Generate more than 1 kg of acutely hazardous waste during any calendar month; or Generate more than 100 kg of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month; or Generate 1 kg or less of acutely hazardous waste during any calendar month, and accumulate more than 1kg of acutely hazardous waste at any time; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste during any calendar month, and accumulated more than 100 kg of that material at any time. Small Quantity Generators: Generate more than 100 and less than 1000 kilograms of hazardous waste during any calendar month and accumulate less than 6000 kg of hazardous waste at any time; or Generate 100 kg or less of hazardous waste during any calendar month, and accumulate more than 1000 kg of hazardous waste at any time. Conditionally Exempt Small Quantity Generators: Generate 100 kilograms or less of hazardous waste per calendar month, and accumulate 1000 kg or less of hazardous waste at any time; or Generate one kilogram or less of acutely hazardous waste per calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste. NLRRCRAT No Longer Regulated RCRA Non-CORRACTS TSD Facilities VERSION DATE: 3/2013 This database includes RCRA Non-Corrective Action TSD facilities that are no longer regulated by the United States Environmental Protection Agency or do not meet other RCRA reporting requirements. This listing includes facilities that formerly treated, stored or disposed of hazardous waste. NPDESR08 National Pollutant Discharge Elimination System VERSION DATE: 4/2007 Information in this database is extracted from the Water Permit Compliance System (PCS) database which is used by United States Environmental Protection Agency to track surface water permits issued under the Clean Water Act. This database includes permitted facilities located in www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DEFINITIONS 5 ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. The NPDES database was collected from December 2002 until April 2007. Refer to the PCS and/or ICIS-NPDES database as source of current data. NPL National Priorities List VERSION DATE: 12/2012 This database includes United States Environmental Protection Agency (EPA) National Priorities List sites that fall under the EPA's Superfund program, established to fund the cleanup of the most serious uncontrolled or abandoned hazardous waste sites identified for possible long-term remedial action. Open Dump Inventory ODI VERSION DATE: 6/1985 The open dump inventory was published by the United States Environmental Protection Agency. An “open dump” is defined as a facility or site where solid waste is disposed of which is not a sanitary landfill which meets the criteria promulgated under section 4004 of the Solid Waste Disposal Act (42 U.S.C. 6944) and which is not a facility for disposal of hazardous waste. This inventory has not been updated since June 1985. PADS PCB Activity Database System VERSION DATE: 11/2012 The PCB Activity Database System (PADS) is used by the United States Environmental Protection Agency to monitor the activities of polychlorinated biphenyls (PCB) handlers. PCSR08 Permit Compliance System VERSION DATE: 8/2012 The Permit Compliance System is used in tracking enforcement status and permit compliance of facilities controlled by the National Pollutant Discharge Elimination System (NPDES) under the Clean Water Act and is maintained by the United States Environmental Protection Agency's Office of Compliance. PCS is designed to support the NPDES program at the state, regional, and national levels. This database includes permitted facilities located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. PNPL Proposed National Priorities List VERSION DATE: 12/2012 This database contains sites proposed to be included on the National Priorities List (NPL) in the Federal Register. The United States Environmental Protection Agency investigates these sites to determine if they may present long-term threats to public health or the environment. www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DEFINITIONS 6 ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL RCRAC Resource Conservation & Recovery Act - Corrective Action Facilities VERSION DATE: 3/2013 This database includes hazardous waste sites listed with corrective action activity in the RCRAInfo system. The Corrective Action Program requires owners or operators of RCRA facilities (or treatment, storage, and disposal facilities) to investigate and cleanup contamination in order to protect human health and the environment. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). RCRAGR08 Resource Conservation & Recovery Act - Generator Facilities VERSION DATE: 3/2013 This database includes sites listed as generators of hazardous waste (large, small, and exempt) in the RCRAInfo system. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). This database includes sites located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. Large Quantity Generators: Generate 1,000 kg or more of hazardous waste during any calendar month; or Generate more than 1 kg of acutely hazardous waste during any calendar month; or Generate more than 100 kg of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month; or Generate 1 kg or less of acutely hazardous waste during any calendar month, and accumulate more than 1kg of acutely hazardous waste at any time; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste during any calendar month, and accumulated more than 100 kg of that material at any time. Small Quantity Generators: Generate more than 100 and less than 1000 kilograms of hazardous waste during any calendar month and accumulate less than 6000 kg of hazardous waste at any time; or Generate 100 kg or less of hazardous waste during any calendar month, and accumulate more than 1000 kg of hazardous waste at any time. Conditionally Exempt Small Quantity Generators: Generate 100 kilograms or less of hazardous waste per calendar month, and accumulate 1000 kg or less of hazardous waste at any time; or Generate one kilogram or less of acutely hazardous waste per calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DEFINITIONS 7 ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL waste during any calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste. RCRASC RCRA Sites with Controls VERSION DATE: 6/2012 This list of Resource Conservation and Recovery Act sites with institutional controls in place is provided by the U.S. Environmental Protection Agency. RCRAT Resource Conservation & Recovery Act - Treatment, Storage & Disposal Facilities VERSION DATE: 3/2013 This database includes Non-Corrective Action sites listed as treatment, storage and/or disposal facilities of hazardous waste in the RCRAInfo system. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). RODS Record of Decision System VERSION DATE: 1/2013 These decision documents maintained by the United States Environmental Protection Agency describe the chosen remedy for NPL (Superfund) site remediation. They also include site history, site description, site characteristics, community participation, enforcement activities, past and present activities, contaminated media, the contaminants present, and scope and role of response action. SFLIENS CERCLIS Liens VERSION DATE: 6/2012 A Federal CERCLA ("Superfund") lien can exist by operation of law at any site or property at which United States Environmental Protection Agency has spent Superfund monies. These monies are spent to investigate and address releases and threatened releases of contamination. CERCLIS provides information as to the identity of these sites and properties. This database contains those CERCLIS sites where the Lien on Property action is complete. SSTS Section Seven Tracking System VERSION DATE: 12/2009 The United States Environmental Protection Agency tracks information on pesticide establishments through the Section Seven Tracking System (SSTS). SSTS records the registration of new www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DEFINITIONS 8 ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL establishments and records pesticide production at each establishment. The Federal Insecticide, Fungicide and Rodenticide Act (FIFRA) requires that production of pesticides or devices be conducted in a registered pesticide-producing or device-producing establishment. ("Production" includes formulation, packaging, repackaging, and relabeling.) Toxics Release Inventory TRI VERSION DATE: 12/2011 The Toxics Release Inventory, provided by the United States Environmental Protection Agency, includes data on toxic chemical releases and waste management activities from certain industries as well as federal facilities. This inventory contains information about the types and amounts of toxic chemicals that are released each year to the air, water, and land as well as information on the quantities of toxic chemicals sent to other facilities for further waste management. TSCA Toxic Substance Control Act Inventory VERSION DATE: 12/2006 The Toxic Substances Control Act (TSCA) was enacted in 1976 to ensure that chemicals manufactured, imported, processed, or distributed in commerce, or used or disposed of in the United States do not pose any unreasonable risks to human health or the environment. TSCA section 8(b) provides the United States Environmental Protection Agency authority to "compile, keep current, and publish a list of each chemical substance that is manufactured or processed in the United States." This TSCA Chemical Substance Inventory contains non-confidential information on the production amount of toxic chemicals from each manufacturer and importer site. www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DEFINITIONS 9 ENVIRONMENTAL RECORDS DEFINITIONS - STATE (WY) Sites with Institutional Controls in Place IC VERSION DATE: 12/2012 As defined by the Wyoming Department of Environmental Quality (DEQ), institutional controls are legal or administrative measures that limit human exposure to contaminants. Examples include use control areas, easements, zoning restrictions, and deed notices. They are intended to bolster the integrity of remedies and minimize the potential exposure to contamination by limiting land or resource use. This list of sites with institutional controls in place is provided by the DEQ’s Voluntary Remediation Program. LST Leaking Storage Tanks VERSION DATE: 1/2013 This listing of active storage tank facilities with contamination is provided by the Wyoming Department of Environmental Quality’s Storage Tank Program (STP). According to Wyoming Statues 35-11-1414 through 35-11-1428, the state is responsible for remediation of releases from regulated underground storage tanks and certain aboveground storage tanks. The STP rules and regulations apply to all regulated storage tanks in Wyoming. Storage tank owners/operators are entitled to the state corrective action program if they register their tank(s), pay applicable fees, and complete a minimum site assessment (if applicable). State management of remediation is optional for owners; however, almost no tank system owners have elected to complete cleanup at their expense. ORPHANS Orphan Sites VERSION DATE: 1/2013 The Orphan Site listing is provided by the Wyoming Department of Environmental Quality (DEQ). Under the Environmental Quality Act “Orphan Sites” are defined as: Sites where the DEQ determines that there is no viable party that is responsible for causing or contributing to the contamination present at the site; Sites where DEQ has issued a no further action letter, and where there is a subsequent discovery of contamination which was present at the site when the no further action letter was issued; Spill sites, where DEQ determines that the person responsible for the spill cannot be identified or where DEQ must take prompt action to prevent hazards to human health or the environment at a site where a responsible party fails to act promptly. Storage Tanks ST VERSION DATE: 1/2013 This listing contains active and inactive storage tank facilities regulated by the Wyoming Department of Environmental Quality’s Storage Tank Program (STP). The STP regulates underground storage tanks (USTs) that contain petroleum or hazardous substances; USTs that are larger than 110 gallons or 1,100 gallons on a farm, ranch, or residence; and those that are not heating oil tanks. The STP regulates aboveground storage tanks (ASTs) only if they contain gasoline or diesel, and they are used by a fuel dealer to directly fuel vehicles. The STP does not www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DEFINITIONS 10 ENVIRONMENTAL RECORDS DEFINITIONS - STATE (WY) regulate septic tanks, water storage tanks, hazardous substance ASTs, heating oil tanks, bulk plants, oil refineries, interstate pipeline breakout tanks, or temporary construction ASTs. SWF Permitted Solid Waste Facilities VERSION DATE: 8/2012 This listing of permitted solid waste facilities is provided by the Solid and Hazardous Waste Division (SHWD) of the Wyoming Department of Environmental Quality. The SHWD’s Solid Waste and Permitting Corrective Action Program is responsible for permitting the location, design, construction, operation, monitoring, closure and post-closure care and remediation of solid waste management facilities. The solid waste facilities that are regulated by this program include local community landfills (both operating and closed), municipal waste baling stations and transfer facilities, industrial waste landfills, industrial waste treatment facilities and units, and used oil storage facilities. VRPBF Voluntary Remediation Program and Brownfield Sites VERSION DATE: 12/2012 Wyoming’s Voluntary Remediation Program (VRP) was created by the Wyoming Legislature in 2000 to create new opportunities, procedures, standards and incentives for voluntary remediation of contaminated properties. In order to encourage more people to participate in the VRP, the Wyoming Department of Environmental Quality (DEQ) obtained a grant from the U.S. Environmental Protection Agency to provide technical assistance (Brownfields Assistance) at brownfield properties that are eligible to participate in Wyoming’s VRP. This DEQ listing contains both VRP and Brownfield properties. www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DEFINITIONS 11 ENVIRONMENTAL RECORDS DEFINITIONS - TRIBAL INDIANRES Indian Reservations VERSION DATE: 1/2000 The Department of Interior and Bureau of Indian Affairs maintains this database that includes American Indian Reservations, off-reservation trust lands, public domain allotments, Alaska Native Regional Corporations and Recognized State Reservations. LUSTR08 Leaking Underground Storage Tanks On Tribal Lands VERSION DATE: 2/2013 This database, provided by the United States Environmental Protection Agency (EPA), contains leaking underground storage tanks on Tribal lands located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. ODINDIAN Open Dump Inventory on Tribal Lands VERSION DATE: 11/2006 This Indian Health Service database contains information about facilities and sites on tribal lands where solid waste is disposed of, which are not sanitary landfills or hazardous waste disposal facilities, and which meet the criteria promulgated under section 4004 of the Solid Waste Disposal Act (42 U.S.C. 6944). USTR08 Underground Storage Tanks On Tribal Lands VERSION DATE: 2/2013 This database, provided by the United States Environmental Protection Agency (EPA), contains underground storage tanks on Tribal lands located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 DEFINITIONS 12 APPENDIX E SITE PHOTOGRAPHS Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705 Photo 1 View is south of floor drain on west end of basement. Photo 3 View of body repair anchors in north end of west portion of basement. Reliable ■ Responsive ■ Resourceful Photo 2 View is east of filled in floor drain in west portion of basement. Photo 4 View is north of oil-water separator in basement. Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705 Photo 5 View of storm water sump in southwest corner of west portion of basement. Photo 7 Transmission fluid stain in south end of west portion of basement. Reliable ■ Responsive ■ Resourceful Photo 6 View of sanitary sewer sump in southwest corner of west portion of basement. Photo 8 View of large stain in south end of west portion of basement. Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705 Photo 9 View of footer cut along the south wall of the ramp into the basement in the west portion of the basement. Photo 11 View of groundwater sump in the Body Parts room in the east portion of the basement. Reliable ■ Responsive ■ Resourceful Photo 10 View is north of re-plumbing floor cuts to sanitary sewer sump in northwest corner of east portion of basement. Photo 12 View is east of east portion of basement. Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705 Photo 13 Photo 15 View is north of groundwater sump along north wall of east portion of basement. View is west of floor drain and exhaust system through east portion of first floor. Reliable ■ Responsive ■ Resourceful Photo 14 View of footer cut along south wall of east portion of first floor. Photo 16 View is south of oil-water separator in east portion of first floor. Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705 Photo 17 View is east of sand trap in east portion of first floor. Photo 19 Floor penetration for underground hydraulic hoist used in east portion of first floor. Reliable ■ Responsive ■ Resourceful Photo 18 Floor penetration for aboveground electric hoists used in east portion of first floor. Photo 20 View is northwest of east northwest end of east portion of first floor showing floor drains. Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705 Photo 21 View of showroom in west portion of first floor. Photo 22 View is south of roof top parking on west portion of building. Photo 23 View is east of roof of east portion of building. Photo 24 View is southeast of west parking lot. Photo 25 View is southeast of east parking lot. Photo 26 Northwest adjoining property. Reliable ■ Responsive ■ Resourceful Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705 Photo 27 North adjoining property. Photo 29 East adjoining properties. Reliable ■ Responsive ■ Resourceful Photo 28 North and northwest adjoining properties. Photo 30 Site building and attached south adjoining property. Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705 East parking lot of site and neighboring south adjoining property. Photo 32 South adjoining property. Photo 33 Southwest adjoining property. Photo 34 West adjoining property. Photo 35 West adjoining property. Photo 36 View is east of site building. Photo 31 Reliable ■ Responsive ■ Resourceful Phase I Environmental Site Assessment New Cheyenne Public Safety Center ■ Cheyenne, WY Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705 Photo 37 View is southeast of site building. Reliable ■ Responsive ■ Resourceful APPENDIX F CREDENTIALS CLAY MUIRHEAD, P.E. SENIOR ENVIRONMENTAL ENGINEER, PRINCIPAL & ENVIRONMENTAL MANAGER PROFESSIONAL EXPERIENCE Mr. Muirhead has over 20 years of experience in environmental engineering, due diligence services (Phase I and II Environmental Site Assessments), Federal Brownfields and Wyoming Voluntary Remediation Program assessments, solid waste engineering, and construction management. He is a principal and manager of environmental services in Terracon’s Cheyenne office. PROJECT EXPERIENCE – Environmental Site Assessments • Phase I and II Environmental Site Assessments, Various Sites Wyoming, Colorado and Nebraska Performed Phase I Environmental Site Assessments on various commercial, industrial and agricultural properties and facilities located throughout Wyoming, Colorado and Nebraska. Clients have included Albertson’s, American National Bank, Cheyenne LEADS, City of Cheyenne, Community First National Bank, Cracker Barrel Restaurants, Gundle, Halladay Motors, Koll Telecommunications, McLeod USA, New Frontier Bank, Sierra Trading Post, Simon Contractors, U.S. Bank, VAE Nortrak, Volk Real Estate, Wal-Mart, Wendy’s Restaurants, Wyoming Association of Municipalities, Wyoming Bank and Trust, and more. Phase II ESA’s performed on several. • Voluntary Remediation Program Assessment, Cheyenne Transit Facility – Cheyenne, Wyoming Project Manager for Wyoming Voluntary Remediation Program assessment of historic dump site in Cheyenne, WY for development of the site as a transit bus facility. Project included a subsurface site characterization, public meetings, risk assessment and mitigation alternatives. • Brownfield Pilot Assessment, Historic Railroad Roundhouse – Evanston, Wyoming Project Manager for Federal EPA Brownfield Pilot Assessment of historic railroad roundhouse. Project included environmental site assessments, public meetings, human health and ecological risk assessments, and evaluation of mitigation alternatives. • Environmental Feasibility Analysis, Wind Energy Project - Reno Junction, Wyoming Project Manager for environmental feasibility analysis for proposed wind energy project near Reno Junction, WY for Third Planet Windpower. Project included review and mapping of published information for site geotechnical and geological hazards, wetlands, threatened and endangered species, and historic and archeological resources. • WDEQ Subdivision Applications, Various Sites - Laramie County and Platte County, Wyoming Project Manager for various subdivision applications to develop residential subdivisions in which on-site water supply and waste water systems were proposed under the Wyoming Department of Environmental Quality Subdivision Program. The applications included a subsurface soil and groundwater assessment, aquifer testing, and an evaluation of the nitrate impact from the proposed waste water systems. EDUCATION Master of Business Administration, 1987, University of Denver Bachelor of Science, Civil Engineering, 1985, University of Wyoming REGISTRATIONS Professional Engineer: Wyoming CERTIFICATIONS 40-Hour OSHA Hazardous Waste Operations Training Nuclear Density Gauge Safety Training Radiation Safety Training: X-ray Fluorescence Analyzer AFFILIATIONS Cheyenne-Laramie County Corporation for Economic Development (LEADS) Greater Cheyenne Chamber of Commerce Wyoming Engineering Society (WES) Wyoming Solid Waste and Recycling Association (WSWRA), Board Member and Past President Cheyenne Household Hazardous Waste Collection Committee (CH2WC2), Charter Board Member and Publicity Chairman WORK HISTORY Terracon, Environmental Engineer, 1996-present City of Cheyenne, Solid Waste Engineer, 1992-1995 Edward’s Construction, Inc., Estimator/Project Manager, 1991-1992 Homer J. Olsen, Inc., Civil Engineer, 1989-1991 H.J. Stabile and Son, Inc., Estimator, 1987-1989 MUIRHEAD, CLAY 2 PROJECT EXPERIENCE – Environmental Engineering • Operation and Maintenance of Remedial Systems for Leaking Underground Storage Tank Sites – Cheyenne and Rock Springs, WY Project Manager for operation and maintenance of groundwater and vadose zone remedial systems for leaking underground storage tank sites (gasoline and diesel) in Cheyenne and Rock Springs Wyoming. Client is Wyoming Department of Environmental Quality Storage Tank Program. Remedial systems include groundwater extraction, soil vapor extraction, duel phase vapor extraction and air sparge. PROJECT EXPERIENCE – Landfill Siting, Permitting and Design • Variance Application, Lateral Expansion Design, and Permit Application, Eastern Laramie County Solid Waste Disposal District Landfill - Burns, WY Manager for landfill design and permit application project for a lateral and vertical expansion to the Burns Landfill. Prior to the design, Terracon completed a variance application to expand within the prohibited siting Project distance from an occupied dwelling and water well. The project includes a subsurface characterization, public meetings, and a design that is sensitive to the concerns of adjacent landowners. • Title V Air Quality Permit Applications, Casper Regional Landfill and Casper Balefill – Casper, WY Project Manager for preparation of Title V Air Quality Permit Applications for the Casper Regional Landfill and Casper Balefill. Projects included categorization and summary of landfill and balefill point source emissions, process flow diagrams, emissions inventories using the EPA Landfill Gas Emission Model, and WDEQ/Air Quality Division (AQD) permit applications. • Siting, Permitting and Design of New Landfill – Cheyenne, Wyoming Project Manager for politically sensitive, multi-year project for siting, permitting and design of new municipal solid waste landfill for Cheyenne and Western Laramie County, WY. The project included coordination of a team of professionals, preparation and execution of a public participation plan, consultation with a public advisory committee appointed by the Mayor, geographic information system (GIS) siting study, geotechnical and multi-aquifer hydrogeological investigation, biological and cultural resource surveys, landfill design with leak detection system, permit application, and construction cost estimates. • Design of Phase III of North Trench, Cheyenne Sanitary Landfill – Cheyenne, Wyoming Project Manager for landfill cell design project for the Cheyenne Sanitary Landfill. Project included a subsurface investigation, liner materials alternative evaluation, surface water drainage design, leachate collection system design, engineered containment system design, contractor bidding services and construction quality assurance services. • Leachate System Design and Management, Cheyenne Sanitary Landfill – Cheyenne, Wyoming Project Manager for leachate system design and management projects for the Cheyenne Sanitary Landfill. Projects included preparation of long-term leachate management plan; storm water and leachate calculations, Hydrologic Evaluation of Landfill Performance (HELP) modeling, underground leachate pipeline design, leachate evaporation pond design, and construction quality assurance (CQA) services. • Alternative Earthen Final Cover Assessment, Cheyenne Sanitary Landfill – Cheyenne, Wyoming Project Manager for alternative earthen final cover (AEFC) feasibility assessment at the Cheyenne Landfill. Project included soil testing and analysis of on site soils, and modeling to compare and evaluate an AEFC with a WDEQ prescriptive final cover system. • Landfill Cap Design, Cheyenne Sanitary Landfill – Cheyenne, Wyoming Project Manager for landfill cap design, surface water run-off design, and construction quality control for the South Trench Cells at the Cheyenne Sanitary Landfill. The cap design utilized a high density polyethylene (HDPE) liner system. • Environmental Compliance Engineering, Cheyenne Sanitary Landfill – Cheyenne, Wyoming Project Manager for comprehensive, multi-year landfill engineering project at the Cheyenne Landfill that included a permit renewal application, creek channel realignment permit with U.S. Army Corps of Engineers and WDEQ, preliminary landfill expansion / new landfill development evaluation citizen landfill advisory committee, multi-aquifer hydrogeologic investigation, vertical expansion design, and Tier 1 NMOC emission rate assessment. MUIRHEAD, CLAY 3 PROJECT EXPERIENCE – Landfill Environmental Monitoring • Environmental Monitoring and Reporting, Casper Regional Landfill and Casper Balefill – Casper, WY Project Manager for multi-year environmental monitoring and reporting projects for Casper Regional Landfill and Casper Balefill. Projects include updating the facility environmental monitoring plans, quality control (QC) review of groundwater sampling data and laboratory results, groundwater data reduction and statistical analysis, landfill gas emission rate calculations and air quality reporting, aerial photography and mapping, volumetric calculations, and quarterly and annual groundwater quality and air emissions reports. • Post Closure Monitoring, Base Landfills - F.E. Warren Air Force Base, Wyoming Project Manager for post closure monitoring project at three landfill sites at F.E. Warren Air Force Base in Cheyenne, Wyoming for the Air Force Center for Environmental Excellence (AFCEE). The project included groundwater, surface water, and methane sampling. Micropurge and diffusion sampling technology used for groundwater sampling. PROJECT EXPERIENCE – Solid Waste Transfer Stations and Recycling Facilities • Transfer Station Permit Application and Household Hazardous Waste Facility Design – City of Cheyenne Transfer Station Project Manager for Wyoming Department of Environmental Quality solid waste permit application for the Felix Pino Transfer Station in Cheyenne, WY. The project included the design and permitting of a permanent household hazardous waste (HHW) facility at the transfer station. • Transfer Station Permit Application, City of Casper Solid Waste Transfer Facility – Casper, Wyoming Project Manager for Wyoming Department of Environmental Quality solid waste permit renewal application for the City of Casper Solid Waste Transfer Facility in Casper, WY. The facility is the largest municipal solid waste (MSW) baling facility in WY and includes a sophisticated scale house, multi-level baling facility, compost facility, household hazardous waste (HHW) facility, and recycling center. • Solid Waste Baler Evaluation and Replacement, Casper Balefill – Casper, Wyoming Project Manager on multi-year baler evaluation and replacement project for the Casper Balefill Transfer Station. Project includes research of solid waste baling and bale bag/wrapping equipment, tours of select solid waste baling facilities throughout the United States, equipment cost estimates, building modifications, bid specifications, bidding services, and construction quality assurance (CQA) services. • E-Waste Recycling Facility Permit Application, Tatooine Electronic Systems - Cheyenne, WY Project Manager for first electronic waste (e-waste) recycling facility permit from Wyoming Department of Environmental Quality (WDEQ). Project included negotiations with WDEQ to develop standards for e-waste recycling facilities, preparation of a permit application for approval by the WDEQ, and public meetings. ADDITIONAL COURSES Senior Leadership Course, Terracon Consultants, Inc., Olathe, Kansas. Fundamentals of Professional Practice, ASFE, Kansas City, Kansas. Designing and Implementing Alternative Earthen Final Covers for Waste Containment Facilities, University of Wisconsin, Held at University of California, Los Angeles (UCLA). Fundamentals of Groundwater Contamination and Remediation Techniques, University of Wisconsin, Madison, Wisconsin. Sanitary Landfill Design, University of Wisconsin, Madison, Wisconsin.