Terracon Final Phase I ESA Report

Transcription

Terracon Final Phase I ESA Report
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center
West 17th and Pioneer Ave
Cheyenne, Laramie County, WY
April 30, 2013
Terracon Project No. 24137705
Prepared for:
City of Cheyenne
Cheyenne, Wyoming
Prepared by:
Terracon Consultants, Inc.
Cheyenne, Wyoming
TABLE OF CONTENTS
Page No.
EXECUTIVE SUMMARY ............................................................................................................................... i
Findings ............................................................................................................................................. i
Conclusions .......................................................................................................................................ii
Recommendations ........................................................................................................................... iii
1.0
INTRODUCTION.............................................................................................................................. 1
1.1
Site Description ................................................................................................................... 1
1.2
Scope of Services ............................................................................................................... 1
1.3
Standard of Care ................................................................................................................. 2
1.4
Additional Scope Limitations, ASTM Deviations and Significant Data Gaps ...................... 2
1.5
Reliance .............................................................................................................................. 3
1.6
Client Provided Information ................................................................................................. 4
2.0
PHYSICAL SETTING ...................................................................................................................... 4
3.0
HISTORICAL USE INFORMATION ................................................................................................ 5
3.1
Historical Topographic Maps .............................................................................................. 5
3.2
Historical Aerial Photographs .............................................................................................. 6
3.3
Historical City Directories .................................................................................................... 7
3.4
Historical Fire Insurance Maps ......................................................................................... 14
3.5
Site Ownership .................................................................................................................. 17
3.6
Title Search ....................................................................................................................... 17
3.7
Environmental Liens.......................................................................................................... 17
3.8
Historical and Site Interviews ............................................................................................ 17
3.9
Prior Report Review .......................................................................................................... 20
3.10
Historical Use Information Summary ................................................................................ 20
4.0
RECORDS REVIEW ...................................................................................................................... 21
4.1
Federal and State/Tribal Databases ................................................................................. 21
4.2
Local Agency Inquiries ...................................................................................................... 31
4.2.1 Fire Department ................................................................................................... 31
4.2.2 Local/Regional Pollution Control Agency ............................................................. 31
4.3
Records Review Summary ............................................................................................... 31
5.0
SITE RECONNAISSANCE ............................................................................................................ 31
5.1
General Site Information ................................................................................................... 31
5.2
Overview of Current Site Occupants and Operations ....................................................... 32
5.3
Site Observations .............................................................................................................. 32
5.4
Site Reconnaissance Summary ........................................................................................ 36
6.0
ADJOINING PROPERTY RECONNAISSANCE ........................................................................... 36
7.0
ADDITIONAL SERVICES .............................................................................................................. 36
8.0
DECLARATION ............................................................................................................................. 37
TABLE OF CONTENTS (continued)
APPENDICES
APPENDIX A
Exhibit 1 - Topographic Map, Exhibit 2 – Site Diagram, Exhibit 3 – Building
Diagram-First Floor, Exhibit 4 – Building Diagram-Basement
APPENDIX B
Description of Terms and Acronyms
APPENDIX C
Historical Documentation and User Questionnaire
APPENDIX D
Environmental Database Information
APPENDIX E
Site Photographs
APPENDIX F
Credentials
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
EXECUTIVE SUMMARY
This Phase I Environmental Site Assessment (ESA) was performed in accordance with
Terracon Proposal No. 2413E009 dated March 11, 2013, and was conducted consistent with
the procedures included in ASTM E 1527-05, Standard Practice for Environmental Site
Assessments: Phase I Environmental Site Assessment Process. The ESA was conducted under
the supervision or responsible charge of Clay Muirhead, P.E., Environmental Professional.
Carrie Harns performed the site reconnaissance on April 30, 2013.
Findings
A cursory summary of findings is provided below. It should be recognized that details were not
included or fully developed in this section, and the report must be read in its entirety for a
comprehensive understanding of the items contained herein.
Site Description and Use
The site includes one building (Dinneen Building) currently used as offices and for storage. The
building includes a basement of approximately 24,000 square feet, a first floor of approximately
30,000 square feet, and a roof top parking deck of approximately 15,000 square feet on the
west portion of the building. The site also includes two parking lots. The west parking lot is used
for paid monthly parking and the east parking lot is rented to Sidles for their parking needs. The
northwest portion of the first floor of the building includes four office suites that are occupied by
Home Instead Senior Care (Suite A), a real estate office (Suite B), Domonkos Law Office (Suite
C), and Wyoming Senior Citizens Inc. (Suite D).
Historical Information
Based on a review of the historical information, the site was developed prior to 1883. Previous
uses of the site included blacksmithing; painting; laundry and dry cleaning; creamery; filling
station; vulcanizing; and auto sales, service, repair, and painting. The east portion of the
existing building on site was thought to have been constructed between 1915 and 1920 and was
used for automobile sales, service, repair, and painting. The west portion of the existing building
on-site was constructed in approximately 1961 and was used for automobile sales, service,
repair and painting. The site was purchased by Dinneen in 1989 and the building was renovated
by Dinneen in 1991. Dinneen used the site for automobile sales, service, repair and painting.
The adjoining properties to the north, east, south and west were developed prior to 1883.
Previous uses of the adjoining properties to the north included painting; machine repair; steam
laundry; a filling station; and auto sales, service, and repair. Previous uses of the adjoining
properties to the east included Chinese laundry; photography; tire sales and service; a filling
station; automobile service and repair; and machine repair. Previous uses of the adjoining
properties to the south included Chinese laundry; painting; blacksmithing; auto repair and
machine repair. Previous uses of the adjoining properties to the west included Chinese laundry;
Responsive ■ Resourceful ■ Reliable
i
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
blacksmithing; auto sales, service and repair; machine repair; and dry cleaning. The above
referenced uses of the site and adjoining properties constitute a REC to the site.
Records Review
Selected federal and state environmental regulatory databases as well as responses from state
and local regulatory agencies were reviewed. Several facilities were identified in the regulatory
databases. Based on distance, environmental setting and/or facility characteristics, the
northeast corner of the site, the northwest adjoining property and three topographically upgradient facilities constitute RECs to the site.
Site Reconnaissance
Based on site reconnaissance, RECs were identified associated with the current site operations
including a former underground hydraulic hoist, oil/water separators, and unidentified floor cuts
and penetrations.
Adjoining Properties
Indications of RECs were not visually observed with the current use of the adjoining properties.
Additional Services
Per the agreed scope of services specified in the proposal, the following additional services
were conducted: Asbestos Survey. Please refer to the IHI Environmental Asbestos-Containing
Material Field Survey Report (IHI Project No. AM137527) for the findings of these assessments.
Conclusions
We have performed a Phase I ESA consistent with the procedures included in ASTM Practice
E 1527-05 at 410 W 17th, 416 W 17th, 405 W 18th, 1704 Pioneer, and the associated parking
lots, Cheyenne, Laramie County, Wyoming, the site. Recognized environmental conditions were
identified in connection with the site and include the following:

Past uses of the site and adjoining properties;

Interviews identifying the northwest adjoining property as a contaminated site;

Regulatory database listings that include the site and three topographically upgradient facilities; and

Observations of a former underground hydraulic hoist, oil/water separators and
unidentified floor cuts and penetrations in the building.
Responsive ■ Resourceful ■ Reliable
ii
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Recommendations
Based on the scope of services, limitations, and findings of this assessment, Terracon
recommends a limited site investigation to obtain additional information regarding the potential
impact to the site from the RECs identified herein.
Responsive ■ Resourceful ■ Reliable
iii
PHASE I ENVIRONMENTAL SITE ASSESSMENT
NEW CHEYENNE PUBLIC SAFETY CENTER
WEST 17TH AND PIONEER AVE
CHEYENNE, LARAMIE COUNTY, WYOMING
Terracon Project No. 24137705
April 30, 2013
1.0
INTRODUCTION
1.1
Site Description
Site Name
New Cheyenne Public Safety Center
Site Location/Address
410 W 17th, 416 W 17th, 405 W 18th, and 1704 Pioneer,
Cheyenne, Laramie County, Wyoming
Land Area
Approximately 1.31 acres
Site Improvements
The north portion of the site includes a building with an
approximately 30,000 square foot first floor, an approximately
24,000 square foot basement and approximately 15,000 square
feet of parking area on the roof of the west portion of the building.
The remainder of the site is two paved parking lots on the south
end of the site. The building was renovated in 1991. The storm
drain system in the alley running through the middle of the site was
improved in 1991. The overhead electrical lines were also buried in
the alley in 1991.
The site location is depicted on Exhibit 1 of Appendix A, which was reproduced from a portion of
the USGS 7.5-minute series topographic map. A Site Diagram of the site and adjoining
properties is included as Exhibit 2 of Appendix A. Site Building Diagrams are included as
Exhibits 3 and 4 of Appendix A. Acronyms and terms used in this report are described in
Appendix B.
1.2
Scope of Services
This Phase I ESA was performed in accordance with Terracon Proposal No. 2413E009 dated
March 11, 2013, and was conducted consistent with the procedures included in ASTM E 152705, Standard Practice for Environmental Site Assessments: Phase I Environmental Site
Assessment Process. The purpose of this ESA was to assist the client in developing information
to identify Recognized Environmental Conditions (RECs) in connection with the site as reflected
by the scope of this report. This purpose was undertaken through user-provided information, a
regulatory database review, historical and physical records review, interviews, including local
government inquiries, as applicable, user-provided information, and a visual noninvasive
Responsive ■ Resourceful ■ Reliable
1
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
reconnaissance of the site and adjoining properties. Limitations, ASTM deviations, and
significant data gaps (if identified) are noted in the applicable sections of the report.
As requested by the client, the following additional services were performed:

1.3
Asbestos Survey
Standard of Care
This ESA was performed in accordance with generally accepted practices of this profession,
undertaken in similar studies at the same time and in the same geographical area. We have
endeavored to meet this standard of care, but may be limited by conditions encountered during
performance, a client-driven scope of work, or inability to review information not received by the
report date. Where appropriate, these limitations are discussed in the text of the report, and an
evaluation of their significance with respect to our findings has been conducted.
Phase I ESAs, such as the one performed at this site, are of limited scope, are noninvasive, and
cannot eliminate the potential that hazardous, toxic, or petroleum substances are present or
have been released at the site beyond what is identified by the limited scope of this ESA. In
conducting the limited scope of services described herein, certain sources of information and
public records were not reviewed. It should be recognized that environmental concerns may be
documented in public records that were not reviewed. No ESA can wholly eliminate uncertainty
regarding the potential for RECs in connection with a property. Performance of this practice is
intended to reduce, but not eliminate, uncertainty regarding the potential for RECs. No
warranties, express or implied, are intended or made. The limitations herein must be considered
when the user of this report formulates opinions as to risks associated with the site or otherwise
uses the report for any other purpose. These risks may be further evaluated – but not eliminated
– through additional research or assessment. We will, upon request, advise you of additional
research or assessment options that may be available and associated costs.
1.4
Additional Scope Limitations, ASTM Deviations and Significant Data Gaps
Based upon the agreed-on scope of services, this ESA did not include subsurface or other
invasive assessments, business environmental risk evaluations, or other services not
particularly identified and discussed herein, including an evaluation of vapor encroachment
conditions. Credentials of the company (Statement of Qualifications) have not been included in
this report but are available upon request. Pertinent documents are referred to in the text of this
report, and a separate reference section has not been included. Reasonable attempts were
made to obtain information within the scope and time constraints set forth by the client;
however, in some instances, information requested is not, or was not, received by the issuance
date of the report. Information obtained for this ESA was received from several sources that we
believe to be reliable; nonetheless, the authenticity or reliability of these sources cannot and is
not warranted hereunder. This ESA was further limited by the following:
Responsive ■ Resourceful ■ Reliable
2
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705


Historic information was not reasonably ascertainable back to the date the site
was developed, which is believed to be prior to 1883. Uses of the site were
described as far back as 1883.
Office B-1 was locked and inaccessible during the site reconnaissance.
An evaluation of the significance of these limitations and missing information with respect to our
findings has been conducted, and where appropriate, significant data gaps are identified and
discussed in the text of the report. However, it should be recognized that an evaluation of
significant data gaps is based on the information available at the time of report issuance, and an
evaluation of information received after the report issuance date may result in an alteration of
our conclusions, recommendations, or opinions. We have no obligation to provide information
obtained or discovered by us after the issuance date of the report, or to perform any additional
services, regardless of whether the information would affect any conclusions, recommendations,
or opinions in the report. This disclaimer specifically applies to any information that has not been
provided by the client.
This report represents our service to you as of the report date and constitutes our final
document; its text may not be altered after final issuance. Findings in this report are based upon
the site‟s current utilization, information derived from the most recent reconnaissance and from
other activities described herein; such information is subject to change. Certain indicators of the
presence of hazardous substances or petroleum products may have been latent, inaccessible,
unobservable, or not present during the most recent reconnaissance and may subsequently
become observable (such as after site renovation or development). Further, these services are
not to be construed as legal interpretation or advice.
1.5
Reliance
This ESA report is prepared for the exclusive use and reliance of City of Cheyenne. Use or
reliance by any other party is prohibited without the written authorization of City of Cheyenne
and Terracon Consultants, Inc. (Terracon).
Reliance on the ESA by the client and all authorized parties will be subject to the terms,
conditions and limitations stated in the proposal, ESA report, and Terracon‟s Agreement for
Services. The limitation of liability defined in the Agreement for Services is the aggregate limit of
Terracon‟s liability to the client and all relying parties.
Continued viability of this report is subject to ASTM E 1527-05 Sections 4.6 and 4.8. If the ESA
will be used by a different user (third party) than the user for whom the ESA was originally
prepared, the third party must also satisfy the user‟s responsibilities in Section 6 of ASTM
E 1527-05.
Responsive ■ Resourceful ■ Reliable
3
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
1.6
Client Provided Information
Prior to the site visit, Lt. Mark Munari, client‟s representative, was asked to provide the following
user questionnaire information as described in ASTM E1527-05 Section 6.
Client Questionnaire Responses
Client Questionnaire Item
Client’s
Response
Client Did Not
Respond
Yes
No
Aware of any Environmental Cleanup Liens against the site.
X
Actual Knowledge of Environmental Liens or Activity Use
Limitations (AULs) that may encumber the site.
X
Aware of any Specialized Knowledge or Experience related to the
site or nearby properties.
X
Actual Knowledge of a Significantly Lower Purchase Price because
of hazardous substances or petroleum products.
X
Commonly Known or Reasonably Ascertainable Information that is
material to a release in connection with the site.
X
Obvious Indicators of Contamination at the site.
X
Terracon‟s consideration of the client provided information did not identify RECs. A copy of the
questionnaire is included in Appendix C.
2.0
PHYSICAL SETTING
Physical Setting Information
Source
Topography (Refer to Appendix A for an excerpt of the Topographic Map)
Site Elevation
Surface Runoff/
Topographic
Gradient
Closest
Water
Soil Type
Description
Surface
Approximately 6068 feet (NGVD)
Relatively flat area with general gradient towards the
southeast based on site observations
Crow Creek, approximately 2500 feet to the east of
the site.
Soil Characteristics
land-Poposhia-Trimad complex,
Urban
3-15%
slopes
Poposhia soil is very deep, well drained, moderately
permeable and formed in silty alluvium. The surface
layer is brown silt loam, about 6" thick and the
Responsive ■ Resourceful ■ Reliable
USGS Topographic Map,
Cheyenne North,
Wyoming Quadrangle,
1994
Laramie County, WY
USDA-NRCS Web Soil
Survey issued February
22, 2007
4
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Physical Setting Information
Source
underlying material to a depth of 60"+ is very pale
brown silt loam. Trimad soil is very deep, well
drained, moderately permeable and formed in very
gravelly loamy alluvium. The upper part of the
surface layer is dark brown loam about 3" thick and
the lower 7" is brown gravelly loam. The upper 24"
of the subsoil is very pale brown very gravelly sandy
loam.
Geology/Hydrogeology
Formation
Deposits of Fox Farm Terrace
Description
Consists generally of gravel and gravelly sand
overlain by 2-5 feet of silt and sand. Mostly
subrounded and subangular pebbles and small
cobbles; some large cobbles and a few small
boulders may be present.
Thickness is
approximately 25 feet.
M.E. Cooley & M.A. Crist,
Geohydrology of the High
Plains Aquifer System,
Cheyenne Urban Area,
Wyoming, USGS WRIR
92-4047.
M.E. Cooley & M.A. Crist,
Geohydrology of the High
Plains Aquifer System,
Cheyenne Urban Area,
Wyoming, USGS WRIR
92-4047.
Estimated Depth to
First Occurrence of
Groundwater
Approximately 13 feet
*Hydrogeologic
Gradient
Not known - may be inferred to be parallel to topographic gradient (primarily to the
southeast).
* The groundwater flow direction and the depth to shallow, unconfined groundwater, if present, would likely vary depending upon
seasonal variations in rainfall and other hydrogeological features. Without the benefit of on-site groundwater monitoring wells
surveyed to a datum, groundwater depth and flow direction beneath the site cannot be directly ascertained.
3.0
HISTORICAL USE INFORMATION
Terracon reviewed the following historical sources for indications of RECs. A summary of the
historical review is included at the end of the Historical Use Information section. Copies of
selected historical documents are included in Appendix C.
3.1
Historical Topographic Maps
Readily available historical USGS topographic maps were not reviewed to evaluate land
development in connection with the site because the site is located in a densely developed part
of the city.
Responsive ■ Resourceful ■ Reliable
5
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
3.2
Historical Aerial Photographs
Selected historical aerial photographs provided by Historic Information Gatherers (HIG) were
reviewed at approximately 10 to 15 year intervals, if readily available, to obtain information
concerning the history of development on and near the site. Evaluation of these aerials may be
limited by a photo‟s quality and scale. Selected photographs are summarized below.






HIG, photo ID# 132599, 1947, 1” = 800‟
HIG, photo ID# 132599, 1960, 1” = 500‟
HIG, photo ID# 132599, 1990, 1” = 800‟
HIG, photo ID# 132599, 1994, 1” = 500‟
HIG, photo ID# 132599, 2006, 1” = 500‟
HIG, photo ID# 132599, 2012, 1” = 500‟
Historical Aerial Photographs
Direction
Description
Site
Due to the scale of the photographs, the description of the “site” will include the entire
th
th
block from W 17 north to W 18 and Thomes Ave east to Pioneer Ave. The block
appears to include several buildings (1947, 1960). Fewer buildings are seen and there
appears to be a parking lot (1990). There appears to be two paved parking lots and
the remainder of the block is buildings (1994). The block appears unchanged (2006,
2012).
North
Due to the scale of the photographs, the description of the north adjoining properties
th
th
will include the three blocks from W 18 north to W 19 and O‟Neil Ave east to Carey
Ave. Each block includes several buildings (1947). The blocks appear unchanged
(1960). There appear to be fewer buildings and more parking areas (1990). The
blocks appear unchanged (1994). There appear to be several new and different
buildings and paved parking areas (2006). The blocks appear unchanged (2012).
East
Due to the scale of the photographs, the description of the east adjoining properties
th
th
will include the block from W 17 north to W 18 and from Pioneer Ave east to Carey
Ave. The block includes several buildings (1947). The structure of the buildings
appears to change over the years (1960, 1990, 1994, 2006, 2012).
South
Due to the scale of the photographs, the description of the south adjoining properties
th
th
will include the three blocks from W 16 (Lincolnway) north to W 17 and from O‟Neil
Ave east to Carey Ave. Each block includes several buildings (1947). The blocks
appear unchanged (1960). The easternmost block appears to no longer include
buildings (1990). The easternmost block appears to be a paved parking lot (1994).
The easternmost block appears as one large structure (2006). There appear to be
fewer buildings and more parking areas on the two westernmost blocks (2012).
Responsive ■ Resourceful ■ Reliable
6
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Direction
Description
West
Due to the scale of the photographs, the description of the west adjoining properties
th
th
will include the block from W 17 north to W 18 and from O‟Neil Ave east to Thomes
Ave. The block appears to include several buildings (1947, 1960). Two buildings are
seen in the block, and the rest of the area appears to be cleared and portions paved
(1990). The block includes two buildings and the remainder of the block appears to be
paved parking areas (1994). The block appears unchanged (2006, 2012).
3.3
Historical City Directories
The Cheyenne, WY city directories used in this study were made available through Laramie
County Library (selected years reviewed: 1902 through 2010) and were reviewed at
approximate ten-year intervals, if readily available. Since these references are copyright
protected, reproductions are not provided in this report. Street listings for the site were not
available prior to 1902. The current street addresses for the site were identified as 410 W 17th
St, 416 W 17th St, 405 W 18th St, and 1704 Pioneer Ave. For the simplicity of the following table,
the “site” listings will include all listings for the block from W 17th north to W 18th and from
Thomes Ave east to Pioneer Ave (Eddy St); however if the address is an adjoining property, it
will be indicated.
Historical City Directories
Direction
Description
1902 – 1706 Eddy St, 1708 Eddy St, 1710 Eddy St, 1716 Eddy St: Residences; 1712
Eddy St (adjoining property): Durant Hose House, residences; 1718 Eddy St:
th
th
Vacant. No listings for W 17 St, W 18 St, and Thomes St.
th
th
th
th
1913-14 – 402 W 17 St, 402 ½ W 17 St, 406 W 17 St, 408 W 17 St (adjoining
th
th
th
properties): Residences; 412 W 17 St, 412 ½ W 17 St, 418 W 17 St, 418 ½ W
th
th
th
th
17 St, 420 W 17 St, 422 W 17 St: Residences; 416 W 17 St: Sherman Hotel.
th
th
417 W 18 St: Residence; 421 W 18 St: Cheyenne Creamery Co. 1707 Thomes St,
1711 Thomes St: Residences. 1712 Eddy St: Fire Department (adjoining property).
th
Site
th
th
1924 – 400 W 17 St, 406 W 17 St: Residences (adjoining properties), 402 W 17
th
St: California Fish Mkt (adjoining property); 404 W 17 St: Vacant (adjoining
th
th
property); 408 W 17 St: Mandanis Bakery & Gro. (adjoining property); 412 W 17
th
th
th
St: Corbet Ice Cream Co.; 416 W 17 St, 416 ½ W 17 St, 418 W 17 St:
th
th
Residences; 420 W 17 St: Vacant; 422 W 17 St: Q & S Oil co., WW Motor Co. 413
th
th
th
th
W 18 St, 415 W 18 St, 417 W 18 St: Residences; 421 W 18 St: Cheyenne
Creamery Co. 1707 Thomes St: Residence; 1709 Thomes St: Modern Method
Beauty Shop; 1711 Thomes St: Cheyenne Radio Shop, The LB Price Mer Co. 1708
Pioneer Ave: Coliseum Billiards, Pioneer Stge & Fur Co; 1708 ½ Pioneer Ave:
Coliseum Dance Hall; 1718 Pioneer Ave: Store Room; 1720 Pioneer Ave: Cheyenne
Sheet Mtl Wks, Residence; 1722 Pioneer Ave: Cheyenne Filling Station.
th
th
1933-34 – 400 W 17 St: Wyo Automotive Co (adjoining property); 406 W 17 St:
Responsive ■ Resourceful ■ Reliable
7
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Direction
Description
th
Mac Marr‟s gro (adjoining property); 408 W 17 St: Matsuhima Takimatsu barber
th
th
(adjoining property); 410 W 17 St: New Method Clnrs; 412 W 17 St: Corbett Ice
th
th
Cream Co, residence; 416 W 17 St: Farris Market meats; 416 ½ W 17 St: Hazel
th
th
Rooms; 418 W 17 St: Baker John A soft drinks; 418 ½ W 17 St: Residence; 422 W
th
th
th
17 St: California Fish Market, residence. 413 W 18 St: Shuman Clnrs; 417 W 18
th
St: Residences; 421 W 18 St: Vacant. 1707 Thomes Ave: Vacant; 1709 Thomes
Ave: Denver Post Agency, Robbins Gilbert B bicycles; 1711 Thomes Ave: Wyo
Poultry & Egg Co whol. 1704 Pioneer Ave: MacMarr Food Store, Chambers Ray
meats; 1704 ½ Pioneer Ave: Coliseum Dance Hall; 1706 Pioneer Ave: Stop Shop
Market gro; 1708 Pioneer Ave: Residence, Brunswick Cigar Store; 1710 Pioneer
Ave: Vacant; 1712 Pioneer Ave: Residences, Capital Battery & Elec Co. (adjoining
property); 1716 Pioneer Ave: Sanitary Home Lndry; 1720 Pioneer Ave: Roe Motor
Co.
th
th
th
th
1945 – 400 W 17 St: United Auto Supply Stores (adjoining property); 404 W 17 St:
th
Fader‟s Gun Shop, residence (adjoining property); 406 W 17 St: Ed‟s Linoleum
th
th
Shop (adjoining property); 406 ½ W 17 St: Vacant (adjoining property); 408 W 17
th
St: Wahl‟s Cycle & Key Shop (adjoining property); 410 W 17 St: Dr Pepper Bottling
th
th
Co, Squirt Bottling Co; 412 W 17 St: Cohen Benj Z meats; 414 W 17 St, 418 ½ W
th
th
th
17 St: Residences; 418 W 17 St: Baker John A liquors; 420 W 17 St: Shamrock
th
th
th
Café; 422 W 17 St: California Fish Market. 413 W 18 St: Elite Clnrs; 417 W 18 St:
th
Residences; 423 W 18 St: United Service Org. 1707 Thomes Ave: West Side Shoe
Shop, McCoy Jas E barber; 1709 Thomes Ave: Kashiwagi Sekichi billiards; 1711
Thomes Ave: Vacant, Manners-Roush Motors auto rprs. 1704 Pioneer Ave: Pioneer
Billiards, Pioneer Studio photogs; 1704 ½ Pioneer Ave: Coliseum Apartments; 1706
Pioneer Ave: Fitch F W electric contr; 1708 Pioneer Ave: Casper Supply Co Inc;
1710 Pioneer Ave: Home Servicing Co furn reprs; 1712 Pioneer Ave: Wyoming
Automotive Co whol (adjoining property); 1718 Pioneer Ave: Sanitary Home
Laundry; 1720 Pioneer Ave: Taylor Pontiac Co.
1955 – 400 W 17 St: United Auto Supply Stores (adjoining property); 406 W 17 St:
th
Frontier Flooring Co (adjoining property); 408 W 17 St: Wahl‟s Cycle & Key Shop
th
th
(adjoining property); 408 ½ W 17 St: Vacant (adjoining property); 410 W 17 St: Dr.
th
th
Pepper Bottling Co; 412 W 17 St: Cheevers Automotive Mach Shop Inc; 414 W 17
th
th
St: Vacant; 416 W 17 St: Baker John A (office), Baker‟s Place; 418 ½ W 17 St:
th
th
Residence; 420 W 17 St: Wheel of Fortune Café; 422 W 17 St: California Fish
th
Market. 423 W 18 St: Montgomery Ward (whse). 1705 Thomes Ave: Veterans
Barber Shop; 1707 Thomes Ave, 1711 Thomes Ave: Vacant; 1709 Thomes Ave:
Hashimoto Itsuki billiards. 1704 Pioneer Ave: Pioneer Billiards; 1704 ½ Pioneer
Billiards: Coliseum Apartments; 1706 Pioneer Ave: Local Finance Co Inc; 1708
Pioneer Ave: Casper Supply Co Inc auto parts; 1712 Pioneer Ave: Wyoming
Automotive Co whol; 1716-20 Pioneer Ave: Taylor Building; 1720 Pioneer Ave:
Taylor Pontiac Co.
th
1965 – 400 W 17 St: Sidles Automotive Supply Store (adjoining property); 406 W
th
th
17 St: Herrin John W acct (adjoining property); 408 W 17 St: Wahl‟s Cycle & Key
th
Shop (adjoining property); 408 ½ W 17 St: Vacant (adjoining property); 410-12 W
th
th
17 St: Cheever‟s Automotive Machine Shop Inc; 418 W 17 St: Klipstein Sales Lot
Responsive ■ Resourceful ■ Reliable
8
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Direction
Description
auto. 1710 Pioneer Ave: Casper Supply Co. Inc auto parts; 1716-20 Pioneer Ave:
th
Taylor Building; 1720 Pioneer Ave: Taylor Pontiac-Buick Co. No listings for W 18 St
and Thomes Ave.
th
1975 – 400 W 17 St: Sidles company automotive parts (adjoining property); 406 W
th
th
17 St: Sidles Co Stge (adjoining property); 408 W 17 St: Wahl‟s Schwinn Cyclery
th
bicycle sls & serv (adjoining property); 410 W 17 St: Cheever‟s Automotive Machine
th
Shop Inc; 416 W 17 St: No Return. 1704 Pioneer Ave, 1706 Pioneer Ave: No
Return; 1710 Pioneer Ave: West Side Community Center; 1712 Pioneer Ave: No
Return (adjoining property); 1716-20 Pioneer Ave: Taylor Building; 1720 Pioneer
th
Ave: Taylor Pontiac-Buick Jeep Co. No listings for W 18 St and Thomes Ave.
th
th
1985 – 400 W 17 St: Sidles Co automotive parts (adjoining property); 406 W 17
th
St: Sidles co automotive pnt (adjoining property); 408 W 17 St: Wahl‟s Schwinn
th
Cyclery bicycle sls & serv (adjoining property); 410 W 17 St: Royal Glass; 416 W
th
17 St: Residence. 1706 Pioneer Ave, 1710 Pioneer Ave: Vacant; 1712 Pioneer
Ave: Vacant (adjoining property); 1720 Pioneer Ave: Mecham Pontiac Buick Jeep
th
Co. No listings for W 18 St and Thomes Ave.
th
1995 – 400 W 17 St: Sidles Co automotive parts (adjoining property); 406 Sidles Co
th
(Auto Paint Sup) (adjoining property); 408 W 17 St: Wahl‟s Cyclery bicycle sls &
th
th
serv (adjoining property); 420 W 17 St: Dinneen Pontiac Buick auto dlrs. 405 W 18
St: Dinneen Pontiac Buick parts dept; 413 Wyoming Senior Citizens Inc; Senior
th
Companion Program, Wyoming Older Workers Program govt agency; 419 W 18 St:
Wyoming Automobile Dealers Assoc. 1723 Thomes Ave: Edward Jones brokerage
firm, BHJ Inc insurance. 1710 Pioneer Ave: Parking Lot; 1712 Pioneer Ave: Ross &
Ross lwyrs, Ross Vincent A atty, Ross Anthony F atty, Santini George atty (adjoining
property).
th
2005 – 406 W 17 St: Sidles Co Automotive Parts auto body shop equip/supl
th
(adjoining property); 408 W 17 St: Advanced Cash SVC loans (adjoining property);
th
th
420 W 17 St: Dinneen Detail Shop auto detail & clean-up serv. 413 W 18 St: WY
Senior Citizens Inc senior citizens serv; ARC Affordable Residential housing
authorities. 1723 Thomes Ave: No current listing, Wyoming Automobile Dealer Assn
associations. 1712 Pioneer Ave: Sonic Drive-In restaurants (adjoining property).
th
2010 – 406 W 17 St: Sidles Co Automotive Paint auto parts & supl- retail-new
th
(adjoining property); 408 W 17 St: Advanced Cash SVC payday loans (adjoining
th
property). 413 W 18 St: Wyoming Senior Citizens Inc senior citizens serv; 419 W
th
18 St: Oswald Peter W. 1723 Thomes Ave: Prudential Financial insurance, Home
Instead Senior Care senior citizens serv. 1712 Pioneer Ave: Clinical Prevention
wellness programs, Corps Today Inc consultants- business, Graham Norris Jr Atty at
Law attorneys, Hibbler Bill G attorneys (adjoining property).
th
North
th
th
th
1902 – (North) 406 W 18 St: Vacant; 410 W 18 St, 412 W 18 St, 416 W 18 St:
th
th
th
Residences. (Northwest) 500 W 18 St: H B Emigh Store; 502 W 18 St, 510 W 18
St: Residences. No listings northeast.
th
th
th
th
1913-14 – (North) 406 W 18 St, 410 W 18 St, 414 W 18 St, 416 W 18 St:
th
Residences; 422 W 18 St: African M E Church. 1808 Eddy St: Residence.
th
th
th
(Northwest) 502 W 18 St: Socialist Headquarters; 504 W 18 St, 510 W 18 St:
Responsive ■ Resourceful ■ Reliable
9
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Direction
Description
Residences. 1804 Thomes St, 1810 Thomes St: Residences. No listings northeast.
th
th
th
1924 – (North) 410 W 18 St, 412 W 18 St: Residences; 414 W 18 St: Residence,
th
Western Poultry House; 422 W 18 St: African M E Church. 1808 Pioneer Ave: City
th
th
Auto Trimming Co. (Northwest) 500 W 18 St, 502 W 18 St: Residences; 504 W
th
th
18 St: Vacant; 506-518 W 18 St: Cheyenne Steam Lndry & Clng Co. 1804
Thomes St, 1810 Thomes St: Residences. No listings northeast.
th
th
1933-34 – (North) 408 W 18 St: Vizina Arth Motor Co; 414 W 18 St: Vacant; 422
th
W 18 St: African M E Ch. 1810 Pioneer Ave: Atlas Tire Shop, Standard Oil Co.
th
th
(Northwest) 500 W 18 St: Faulk Edw H gro; 502 W 18 St: Price L B Merc Co; 504
th
th
W 18 St: Texas Café; 508 W 18 St: Cheyenne Steam Laundry. No listings
northeast.
th
th
th
1945 – (North) 406 W 18 St, 410 W 18 St: Residences; 408 W 18 St: Post Office
th
th
Garage, Capitol Battery & Electric Co; 412 W 18 St: Wood Lunch Room; 418 W 18
th
St: Motor Sales Co used cars; 422 W 18 St: African M E Church. 1800 Pioneer Ave:
Fort Warren Bus Terminal; 1810 Pioneer Ave: Standard Oil Co of Ind (office), War
Manpower Comn US Emp Serv, US Civil Service Comn; State Employment Security
th
th
Comn. (Northwest) 500 W 18 St: American Cleaners & Tailors; 504 W 18 St:
th
Texas Café, residence; 508 W 18 St: Cheyenne Steam Lndry; 1810 Thomes Ave:
Residence. No listings northeast.
th
th
1955 – (Northeast) 324 W 18 St: General Credit Corp. (North) 406 W 18 St, 410 W
th
th
th
18 St: Residences; 408 W 18 St: Pioneer Motor Co; 412 W 18 St: Blu-Inn Café;
th
th
418 W 18 St: Pioneer Motor Co used cars; 422 W 18 St: Allen Chapel African M E
Church. 1804 Pioneer Ave: Jack‟s Standard Serv gas sta; 1810 Pioneer Ave:
Commercial Credit Corp, Standard Oil Co of Ind (ofc), Calver Fire Ins Co.
th
th
(Northwest) 500 W 18 St: American Clns & Tailors; 504 W 18 St: Veteran‟s Café,
th
residence; 508 W 18 St: Cheyenne Steam Lndry & Dry Cleaners. 1810 Thomes
Ave: Residence.
th
th
th
th
1965 – (North) 406 W 18 St, 408 W 18 St, 410 W 18 St: Vacant; 422 W 18 St:
Allen Chapel AME Church. 1800 Pioneer Ave: Central Credit Co; 1808 Pioneer Ave:
State Farm Insurance; 1810 Pioneer Ave: Miller Suyematsu Crowley & Duncan
lwyrs, State Div of Vocational Rehabilitation Center, State Dept of Educ, Orthman
th
th
Allen F acct. (Northwest) 500 W 18 St, 504 W 18 St: Vacant. 1810 Thomes Ave:
Residence. No listings northeast.
th
1975 – (North) 422 W 18 St: Allen Chapel AME Church. 1800 Pioneer Ave: Fidelity
Finance Co loans. 1810 Pioneer Ave: Laramie County Legal Service Inc lwyrs. No
listings northeast or northwest.
1985 – (Northeast) 1803 Pioneer Ave: First Wyoming National Bank (North) 408 W
th
18 St: Vacant. 1800 Pioneer Ave: Vacant, 1810 Pioneer Ave: Barrington Realty Co,
US Veterans Administration. No listings northwest.
th
1995 – (North) 408 W 18 St: Vacant. 1810 Pioneer Ave: First America Title
Guaranty Agency of Cheyenne. (Northeast) 1803 Pioneer Ave: Key Bank of
Wyoming.
2005 – (Northeast) 314 W 18
Responsive ■ Resourceful ■ Reliable
th
St: McGee Hearne & Piaz accountants, Micale
10
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Direction
Description
Management fuel mgmt. (North) 1810 Pioneer Ave: Health First physicians &
th
surgeons, individual. (Northwest): 500 W 18 St: First State Bancshares holding
companies, Security First Bank banks, MKK Consulting Engineers.
th
2010 – (Northeast) 314 W 18 St: McGee Hearne & Piaz LLC accountants, Micale
Management fuel mgmt. (North) 1810 Pioneer Ave: Nursing Board government
th
offices-state. (Northwest): 500 W 18 St: MKK Consulting Engineers, Main Security
First Bank banks.
1902 – 1701-05 Eddy St: Dinneen Bros; 1713 Eddy St, 1715 Eddy St, 1717 Eddy St:
th
th
Residences. 320 W 17 St: Residence; 322 W 17 St: Dinneen Bros. No listing W
th
18 St.
1913-14 – 1711 Eddy St: Cheyenne Rubber Wks; 1713 Eddy St, 1713 ½ Eddy St,
th
th
1715 Eddy St: Residences. 320 W 17 St: Residence; 322 W 17 St: James Bros.
th
No listing W 18 St.
th
1924 – 321 W 18 St: Aero Oil Products Co. 1711 Pioneer Ave: Cheyenne Rubber
th
Tire Wks; 1715 Pioneer Ave, 1719 Pioneer Ave: Residences. 320 W 17 St: Western
th
States Tlg Co.; 322 W 17 St: Wyoming Hdw Co.
th
1933-34 – 321 W 18 St: Smith Frank Auto Parts. 1709 Pioneer Ave: Smith Bros
th
Glass & Paint Co; 1717 Pioneer Ave: Cheyenne Coca-Cola Bottling Co. 320 W 17
th
St: Bruce Wm L locksmith, Meanea F A Harness Shop; 320 ½ W 17 St: Davis Blk
th
furn rms; 322 W 17 St: Wyoming Hdw Co.
th
th
1945 – 321 W 18 St: US Railroad Retirement Bd; 325 W 18 St: Wyo Abstract &
Tile Co. 1715 Pioneer Ave: Wyoming Aircraft School (br); 1719 Pioneer Ave: Smith
th
Frank auto serv; 1721 Pioneer Ave: Vacant. 320 W 17 St: Safeway Stores Inc gro
th
and meats; 320 ½ W 17 St: Davis Apts.
th
East
1955 – 325 W 18 St: General. 1709 Pioneer Ave: Wyoming State Employment
Serv, Employment Security Commission of Wyoming; 1715 Pioneer Ave: Pioneer
th
th
Parking Garage. 320 ½ W 17 St: Davis Block Apartments; 322 W 17 St: Electrical
Center Store No 2.
th
1965 – 325 W 18 St: The Associates loans. 1709 Pioneer Ave: State Employment
Security Comn emp serv; 1715 Pioneer Ave: Goodwill Industries used mdse; 1719
th
th
Pioneer Ave, 1721 Pioneer Ave; Vacant. 320 W 17 St: Vacant; 320 ½ W 17 St:
th
Davis Hotel; 322 W 17 St: Coast to Coast Stores hdw.
th
th
1975 – 321 W 18 St: Acadia Realty Inc, residence; 325 W 18 St: Associates
Financial Serv Co of Wyoing Inc loans. 1715 Pioneer Ave: Davis B Furniture Co. 320
th
th
½ W 17 St: Vacant; 322 W 17 St: Goodwill Industry Of Wyoming.
th
1985 – 321 W 18 St: Friedberg Jack B financial consultant, American Financial Co,
Hercules-Seidel Construction designers bldrs & genl contrs, Sav-On Real Estate;
th
325 W 18 St: Associates Financial Services loans. 1715 Pioneer Ave: Capitol
th
Sewing; 1719 Pioneer Ave: Vacant. 320 W 17 St: Goodwill Industries (Living Skills
th
Ofc); 322 W 17 St: Goodwill Industries of Wyoming (vocatnl dev cntr).
th
th
1995 – 321 W 18 St: Westward Sew By Rena; 325 W 18 St: Cheyenne Family
Chiropractic. 1715 Pioneer Ave: Plush Cue Family Billiards; 1719 Pioneer Ave:
th
Father Abraham christian bookstore. 320 W 17 St: Goodwill Indus of Wyoming Inc
Responsive ■ Resourceful ■ Reliable
11
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Direction
Description
th
living skills center; 322 W 17 St: Goodwill addl sp.
th
2005 – 325 W 18 St: Cheyenne Family Chiropractic chiropractors dc. 1715 Pioneer
th
Ave: Plush Cue Family Billiards billiard parlors. 322 W 17 St: FCS ACC marriage &
family counselors, Frontier Correctional Systems drug detections serv & equip.
th
2010 – 325 W 18 St: Cheyenne Family Chiropractic chiropractors dc; residence.
1715 Pioneer Ave: Plush Cue Family Billiards billiard equip/supl, residence. 322 W
th
17 St: Cheyenne Transitional CTR correctional institutions, residences.
th
th
1902 – (Southeast) 319 W 17 St, 321 ½ W 17 St: Residences. 1621 Eddy St:
th
Residence; 1623 Eddy St: Arcade Saloon. (South): 401 W 17 St: Residence; 409
th
th
th
W 17 St: City Hall; 413-15 W 17 St: Amory; 417 W 17 St: The Sherman Co; 419
th
th
W 17 St: Connor & Miller. 1620-1622 Eddy St: Residence. (Southwest) 501 W 17
th
th
St, 509 ½ W 17 St: Residences; 509 W 17 St: Geyser Steam Laundry.
th
th
1913-14 – (Southeast) 319 W 17 St: Residence. (South) 407 W 17 St: City Hall;
th
th
th
413 W 17 St, 417 W 17 St: Residences; 419 W 17 St: Cheyenne Sign Wks; 421
th
th
W 17 St: Sherman Co; 423 W 17 St: Cheyenne Trading Co. 1621 Thomes St:
th
Residence. 1623 Eddy St: The Arcade, residence. (Southwest) 505 W 17 St, 507 W
th
17 St: Residences. 1620 Thomes St: Residence.
th
th
1924 – (Southeast) 319 W 17 St: Cheyenne Stamp & Novelty Works; 321 W 17
St: Residence. 1621 Pioneer Ave, 1623 Pioneer Ave: Residence; 1621 ½ Pioneer
th
th
th
Ave: IOOF Hall. (South) 411 W 17 St: Loop Café; 413 W 17 St, 415 W 17 St, 417
th
th
th
th
W 17 St, 419 W 17 St: Residences; 421 W 17 St: M & M Garage; 423 W 17 St:
th
th
th
Salvation Army. (Southwest) 505 W 17 St, 507 W 17 St, 509 ½ W 17 St:
th
Residences; 509 W 17 St: Wyo Plmbg & Htg Co.
th
South
th
1933-34 – (Southeast) 319 W 17 St: Modern Beauty Supply; 321 W 17 St: Vacant.
1621 Pioneer Ave: Wyoming Produce Co; 1621 ½ Pioneer Ave: Progress Hall; 1623
th
Pioneer Ave: Van‟s Food Store. (South) 405 W 17 St: Snug Harbor lodging hse;
th
th
407 W 17 St: Yocum Floyd W rstr; 409 W 17 St: Universal Machine Shop; 411 W
th
th
17 St: Silver Abe 2d hd gds; 413 W 17 St: Smith Body and Fender Wks;
th
th
th
residence; 415 W 17 St, 417 W 17 St: Vacant; 419 W 17 St: Ronne Thorwald E
th
th
sign pntr; 421 W 17 St: Swanson Louis plmbr. (Southwest) 505 W 17 St:
th
th
th
Cheyenne Mattress Co, 507 W 17 St, 509 ½ W 17 St: Residences; 509 W 17 St:
Cheyenne Tent & Awning Co, residences.
th
th
1945 – (Southeast) 319 W 17 St: Capital Studio photogs, residence; 321 W 17 St:
Residence. 1621 Pioneer Ave: Caesar‟s Café; 1621 ½ Pioneer Ave: Vacant; 1623
th
th
Pioneer Ave: Pioneer Bar. (South): 405 W 17 St: Snug Harbor lodging; 407 W 17
th
th
St: White House Café; 411 W 17 St: Dreamland Palace restr, residence; 413 W 17
th
th
St: New Moon Barber Shop; 415 W 17 St: Frontier Plmbg & Htg Co; 417 W 17 St:
th
Wstn Paint & Glass Co glass dept; 419 W 17 St: Prairie Advertisers-Signs; 421 W
th
th
17 St: Vacant; 423 W 17 St: The Salvation Army. 1619 Thomes Ave: Salvation
th
Army Rooms. 1622 Pioneer Ave: D&R Appliances. (Southwest) 509 W 17 St:
th
Cheyenne Tent & Awning Co, residence; 509 ½ W 17 St: Residences. 1620
Thomes Ave: Woody‟s Frontier Service gas and oil.
th
th
1955 – (Southeast) 319 W 17 St: Vacant; 321 W 17 St: Residence. 1621 Pioneer
th
Ave: American Legion Post No 93; 1623 Pioneer Ave: Vacant. (South) 405 W 17 St:
Responsive ■ Resourceful ■ Reliable
12
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Direction
Description
th
th
Vacant; 411 W 17 St: Dreamland Palace café, residence; 413 W 17 St:
th
th
Rehabilitation Industries Inc; 415 W 17 St: Vacant; 419-21 W 17 St: Cook P S Co;
th
th
th
423 W 17 St: The Salvation Army. (Southwest) 503 W 17 St: Vacant; 509 W 17
th
St: Cheyenne Tent & Awning Co, residence; 509 ½ W 17 St: Residence.1620
Thomes Ave: Corson W A Co whol auto parts.
th
th
1965 – (Southeast) 319 W 17 St: GAPA Lodge; 321 W 17 St: Vacant. (South) 405
th
th
th
W 17 : No return; 419 W 17 St: Cook P S Co plmbs; 423 W 17 St: The Salvation
th
Army. 1622 Pioneer Ave: Caplan Furn Mart. (Southwest) 509 W 17 St: Cheyenne
th
Tent & Awning Co; 509 ½ W 17 St: Apartments. 1620 Thomes Ave: Corson W A Co
whol auto parts.
th
th
1975 – (Southeast) 319 W 17 St, 321 W 17 St: Vacant. 1623 Pioneer Ave: Vacant.
th
th
(South) 419 W 17 St: Cook P S Co plmbg cntr; 423 W 17 St: Vacant. 1622
th
Pioneer Ave: Dinneen Used Car Lot. (Southwest) 501 W 17 St: Corson W A Co
th
th
auto parts; 509 W 17 St: Cheyenne Tent & Awning Co; 509 ½ W 17 St:
Apartments.
th
th
1985 – (Southeast) 319 W 17 St: City Center Parking Lot. (South) 419 W 17 St:
th
Dinneen‟s Subaru; 421 W 17 St: Parking Lot. 1622 Pioneer Ave: Dinneen Lincoln
th
Mercury Subaru sls (Used Car Lot). (Southwest) 501 W 17 St: Parking Lot; 509 W
th
th
17 St: Vacant; 509 ½ W 17 St: Apartments.1620 Thomes Ave: Modern Trend
Beauty School.
th
1995 – (Southeast) 319 W 17 St: City Parking Lot. 1601 Pioneer Ave: City Public
th
th
Parking Lot. (South) 419 W 17 St: Dinneen‟s Subaru auto dlrs; 421 W 17 St:
th
th
Parking Lot. (Southwest) 501 W 17 St: Parking Lot; 509-509 ½ W 17 St: Vacant (2
Hses). 1620 Thomes Ave: Modern Trend Beauty School.
2005 – (Southeast) 322 W Lincolnway: Cheyenne Transit Program city government.
th
(South) 419 W 17 St: Dinneen auto rpr & serv, Dinneen Subaru auto dlrs-new cars.
(Southwest) 1620 Thomes Ave: Wyoming Trophy & Engraving trophies-mfrs.
2010 – (Southeast) 322 W Lincolnway: Cheyenne Public City Bus bus lines,
Cheyenne Transit Program city government. (Southwest) 1620 Thomes Ave:
Wyoming Trophy & Engraving trophies-mfrs.
1902 – 1710 Thomes St: Residence; 1712 Thomes St: W E Dinneen Wrehouse;
th
th
1720 Thomes St: W E Dinneen Pnt Shop. 502 W 17 St, 508-12 W 17 St:
th
Residences; 504 W 17 St: Vacant.
th
1913-14 – 1722 Thomes St: Wilcox & Son. 500 W 17 St: Geyser Laundry, Cleaning
th
th
& Dye Works; 506 W 17 St, 508 W 17 St: Residences.
West
1924 – 1712 Thomes St: F G Smith Motor Co; 1720 Thomes St: Residence. 500 W
th
17 St: Geyser Laundry Dry Clng & Dye Works.
1933-34 – 1716 Thomes: Welton Garage auto parts; 1722 Thomes: Cook Peter S
th
th
plmbr. 500 W 17 St: Geyser Laundry; 510 W 17 St: Vacant.
th
1945 – 1722 Thomes Ave: Cook P S plmbr. 500 W 17 St: Geyser Laundry.
th
1955 – 1716 Thomes Ave: Klipstein Mtrs. 500 W 17 St: Geyser Lndry-Dry Clns Inc.
1965 – 1716 Thomes Ave: Klipstein Motor Sales Inc auto dlrs.
Responsive ■ Resourceful ■ Reliable
13
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Direction
Description
th
1975 – 1716 Thomes Ave: D J‟s Mazda of Cheyenne sls & serv. 506 W 17 St: State
Employment Service.
th
1985 – 1704 Thomes Ave: Vacant. 504 W 17 St: Downtown West Building; 506 W
th
17 St: State Fire Prevention-Elec Safety.
1995 – 1704 Thomes Ave: Coldwell Banker; 1706 Thomes Ave: Smith Glen E &
th
th
Associates attys. 504 W 17 St: Downtown West Building; 506 W 17 St: T C I
Cablevision.
th
2005 – 504 W 17 St: Adecco employment agencies/opportunit, Affiliated Computer
SVC computer serv, Wise Anne,US Plant Protection federal government, Wyoming
Society of CPA‟s associations, US Food & Nutrition SVC federal government, ACS
th
insurance; 506 W 17 St: Bresnan Communications internet serv.
th
2010 – 504 W 17 St: Adecco Employment SVC employment contractors, ACS info
technology serv.
RECs were identified associated with the site including several dry cleaner and laundry
businesses, oil and automotive businesses, and a gas station. These businesses are
considered RECs due to the potential for past releases of hazardous substances or petroleum
products.
RECs were identified associated with the adjoining properties including several dry cleaners and
laundry businesses, oil companies, gas stations, a photo shop and automotive businesses.
These businesses are considered RECs due to the potential for past releases of hazardous
substances or petroleum products.
3.4
Historical Fire Insurance Maps
Historical fire insurance maps produced by the Sanborn Map Company were requested from
HIG to evaluate past uses and relevant characteristics of the site and surrounding properties.
HIG provided Sanborn maps as summarized below. Several stores and dwellings and various
businesses are shown on the Sanborn maps that were reviewed. Primarily the properties of
environmental interest are listed in the table below.









1883
1886
1890
1894
1907
1912
1923
1931
1960
Responsive ■ Resourceful ■ Reliable
14
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Historical Fire Insurance Maps
Direction
Description
1883: Elephant Corral, Blacksmith, City H & L Co, Crochery Furninture, Millinery,
Portions of the site are covered by the map legend.
1886: H & L Truck, Blacksmith, Hose House being built, Millinery
1890: Blacksmith, Pioneer Hook & Ladder, Stable, Warehouse, Millinery
1894: Blacksmith, Pioneer Hook & Ladder, Millinery, Tailor, Stable
1907: Transfer Stable, Pioneer Hook & Ladder, Pest, Blacksmith, Wall Paper & Paint
Shop, Bicycle repairing, Cobbler, Chinese Laundry, Stables
Site
1912: Creamery with open elevator, Fire Dept., Pioneer Hook & Ladder, Clothing
Cleaning, Shooting Gallery, D.G, Furniture
1923: Creamery with electric motor & open elevator, Filling Station with gas tank,
Sheet Metal Works, Auto Repairing, Fire Department, Dance Hall, Motorcycle
Repairing, Carpenter Shop, Creamery with electric motor, Vulcanizing, Oil in Drums
1931: Creamery with electric motor & open elevator, Boiler Room, Dry Cleaning with
electric motor, Solvent Tanks, Auto Sales & Service, Steam Laundry, Fire
Department, Gas Tank, Miniature Golf Course & Dance Hall, Ware Room, Carpenter
with electric motor, Creamery with electric motor, Auto Body Rep, Sign Printing.
1960: Montgomery Ward with open elevator, Used Auto Sales, Boiler Room, Auto
Sales & Service with Machine Shop, Repairing, Bicycle Repairing.
1883: (North) Allen Chapel. (Northeast) Livery. Northwest block not provided.
1886: (North) Blacksmith, African ME Church. (Northeast) G.C. Charlton Livery.
Northwest block not provided.
1890: (North) African ME Church, Corral. (Northeast) G.C. Charlton Livery.
Northwest block not provided.
1894: (North) African ME Church, Corral. (Northeast) J.M. Neman Livery. Northwest
block not provided.
1907: (North) Wood Working with electric motor, Paint Shop, Storage, AME Church.
Northeast and northwest block not provided.
North
1912: (North) Wood Working with electric motor, Machine Shop with electric motor,
Allen AME Church. (Northwest) Tailor, Cheyenne Steam Laundry with Dry Room,
Engine. Northeast block not provided.
1923: (Northeast) U.S. Post Office. (North) Auto Top Repairing, To Be Auto
Repairing, Allen AME Church. Northwest not provided.
1931: (Northeast) U.S. Post Office. (North) Filling Station with gas tanks (4), Auto
Greasing, Auto Sales & Service, Carpenter with electric motor, Allen AME Church.
Northwest block not provided.
1960: (Northeast) U.S. Post Office. (North) New Car Service, Used Auto Sales, Allen
AME Church. Northwest block not provided.
East
1883: Carpenter, Stable
1886: Chinese Laundry (2), Shoe Maker, Carpenter
Responsive ■ Resourceful ■ Reliable
15
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Direction
Description
1890: Chinese Laundry (2), Shoe Maker, Furniture Upholstery
1894: Chinese Laundry, Carriage Repository, Carpenter, Wallpaper & Paint, Tank
1907: Davis Block, Salvation Army Barracks, Millinery
1912: Photo, Cobbler, Rubber Tires, Millinery
1923: Filling Station, Gas Tank, Oil, Crank Case Service, Vulcanizing, Garage
1931: Machine Shop, Paints & Oils
1960: Goodwill Industries with clothing repair
1883: (South) City Hall Hose House. (Southwest) Blacksmith, Wood Working,
Wagon Shop. (Southeast) Saloon, Furniture & Glassware.
1886: (South) Chinese Laundry, Stable, D.G.&c., City Hall Hose House (Southwest)
Blacksmith. (Southeast) Saloon.
1890: (South) Chinese Laundry, Coal Shed, Carpenter with Paint Shop, City Hall
Hose House and Police Station, D.G&c., Stable (Southwest) Blacksmith, Wagon
Shop. (Southeast) Saloon, Furniture & Jewelry.
1894: (South) Chinese Laundry (2), City Hall Hose House and Police Station, Tin
Shop, Stable. (Southwest) Blacksmith, Wagon Shop. (Southeast) Furniture &
Jewelry, Saloon.
South
1907: Rug Fac with electric motor, Paint Shop and Wall Paper, Carpenter, Bottling
Works, Geyser Laundry with Dry Room, Jail, Furniture, Stable (Southwest)
Blacksmith, Carpenter, Stable. (Southeast) Saloon, Furniture.
1912: (South) Wall Paper, Sign Painting, Bottling Works, Jail, Furniture, Paint
Storage. (Southwest) Blacksmith, Carpenter. (Southeast) Saloon, Furniture.
1923: (South) Salvation Army Hall, Auto Repairing (2), Blacksmith, Carpenter Shop.
(Southeast) Stores. Southwest block not provided.
1931: (South) Salvation Army Hall, Plumbing (2), Machine Shop with electric motor,
Sheet Metal & Tin Shop, Sign Painting, Church of the Nazarene. (Southwest)
Dwellings. (Southeast) Stores.
1960: Salvation Army Hall, Parking, Furniture (Southeast) Store, Club. (Southwest)
Nothing indicated.
1883: Chinese Laundry, Blacksmith, Wood Works
1886: Chinese Laundry, Blacksmith, Wagon Shop, Agriculture Implements
1890: Chinese Laundry, Blacksmith, Wagon Shop, Agriculture Implements
1894: Chinese Laundry, Blacksmith, Wagon Repository, Agriculture Implements
West
1907: Blacksmith, Carpenter, Furniture & Agriculture Implements, Cobbler
1912: Blacksmith, Warehouse, Geyser Laundry
1923: West block not provided
1931: Plumbing, Garage with Auto Repair and gas tank, Gasol & Cleaning with
electric motor
1960: Auto Sales & Service, Dry Cleaning, Vacant & Open Fire Damage
Responsive ■ Resourceful ■ Reliable
16
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
RECs were identified associated with the site including businesses such as dry cleaners,
vulcanizing, gas station, paint shop, and auto repair and service. Gas tanks and solvent tanks
also appeared on the site.
RECs were identified associated with the adjoining properties including businesses such as dry
cleaners, photo shop, oil companies, vulcanizing, gas stations, paint shops, and auto repair and
service. Gas tanks were also identified.
3.5
Site Ownership
Based on a review of information obtained from Laramie County assessor‟s records, the current
site owner is WE Dinneen Incorporated. In addition, previous owners identified included Dinco
Land Incorporated (1989-2011).
3.6
Title Search
At the direction of the client, a title search was not included as part of the scope of services.
Unless notified otherwise, we assume that the client is evaluating this information outside the
scope of this report.
3.7
Environmental Liens
Environmental lien records recorded against the site were not provided by the client. At the
direction of the client, performance of a review of these records was not included as part of the
scope of services and unless notified otherwise, we assume that the client is evaluating this
information outside the scope of this report.
3.8
Historical and Site Interviews
The following individuals were interviewed regarding the current and historical use of the site.
Interviewees
Interviewer
Interviewee/Phone #
Carrie Harns and
Clay
Muirhead,
Terracon
John Dinneen / 307-2216452
Title
Date/Time
04/13/2013 / 11:00 am
Owner/Owner
Representative
05/01/2013 / 3:30 pm
05/02/2013 / 10:00 am
Jennifer Escobedo / 307634-1010
Carrie
Terracon
Harns,
Sara Flanary & Vanessa
Young / 307-778-6644
Occupants
05/02/2013
pm
/
2:00-2:45
Kyle Hoffdahl / 307-4265015
Responsive ■ Resourceful ■ Reliable
17
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Interview with Mr. John Dinneen
Terracon conducted both phone and personal interviews with Mr. John Dinneen, General
Manager of W.E. Dinneen, Inc and Dinco Development LLC, to inquire about historical uses and
known environmental conditions associated with the site. Mr. Dinneen said that he had owned
the property since 1989 and had renovated it in 1991. Mecham Pontiac Buick had owned the
property from approximately 1984 to 1989, and Taylor Pontiac Buick had owned it since
approximately the early 1920s to 1984. Mr. Dinneen stated that he believed the east portion of
the building had been built between approximately 1915 and 1920 and the west portion of the
building had been built in approximately 1961 or 1962. The original use of the basement and
roof of the west portion was for parking. Mr. Dinneen stated the site building had been used as a
car dealership since the early 1920s, but he did not know what it had been used for prior to that.
The first floor of the east portion of the building had once contained a belowground hydraulic
hoist prior to the Dinneen‟s ownership of the building. Several aboveground electric hoists had
been used during the time the Dinneens owned the building. An alignment machine had also
been used during the Dinneen years. Additionally, there had been two waste oil heaters used
for a short amount of time on the first floor of the east portion of the building. The capacity of the
heater tanks was approximately 300 gallons each, and the tanks were used to store waste oil
after the heaters were no longer used. Tri-State Oil Recycling was used to dispose of the waste
oil. Mr. Dinneen was not aware of any USTs on site. Mr. Dinneen stated that there had been a
used oil AST when they bought the building in 1989, but it was hauled off. The basement of the
building had been used for heavy duty mechanical work, car body repair, and painting during
the Taylor and Mecham years. The Dinneens used the basement for detailing and undercoating
only. The Dinneens renovated the building in 1991. Renovations included converting the first
floor of the east portion from a showroom to auto work and maintenance and parts department;
filling in a majority of the floor drains in the west portion of the basement; improving the storm
water system running through the basement floor of the west portion of the building, including
the sump (with pump); replacing the groundwater sumps (with pumps) in the basement of the
east portion of the building; re-plumbing a floor drain to the sanitary sewer sump (with pump) in
the east portion of the basement; improving the south ramp entrance to prevent storm water
from entering the building; burying the electrical lines in the alley; and improving the storm water
drain system in the alley. The basement had flooded prior to the Dinneens purchasing the
property. It was thought to be due to groundwater, so two groundwater pumps were installed in
the east portion of the basement. The Dinneens improved the storm water drain system running
through the west portion of the basement, including the sump (with pump) along the south wall
in the southwest corner of the west portion of the basement, after purchasing the property. Mr.
Dinneen stated that the basement did not flood during the time that they have owned the
building and that the groundwater sump pumps have never run. Solvent washers had been
used in the building, and Safety Kleen was used for disposal and exchange of the used solvent.
Antifreeze was stored in the building in 55-gallon drums, and antifreeze had been washed into
the floor drains during floor cleanings. Dinneen hauled the sump solids to the landfill. The
sumps were tested at a lab approximately every three years for contamination, and the test
results never indicated contamination.
Responsive ■ Resourceful ■ Reliable
18
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
The east portion of the west parking lot had been owned by Royal Glass prior to the Dinneens
purchasing the property from them in 1985. There were two buildings at the south end of the
property and an open lot in the north end. The Dinneens tore down the buildings in
approximately 1988 or 1989 and resurfaced the lot in 1991. Mr. Dinneen said that the
underground electrical connections in the parking lot for the street lights were put in in 1991 as
well. Mr. Dinneen stated that the Henry & Boltoff building occupied the east parking lot prior to
1985 when the Dinneens bought the property. The Dinneens tore down the building and filled
the basement with clean fill dirt. The lot has been rented to Sidles for parking since 1988 and
the lot was surfaced in 1991. Mr. Dinneen said that he was not aware of any dumping, including
that of oils or solvents, on the site. He said that the site has been paved for as long as he can
remember, so he thought the opportunity for dumping would have been very limited.
WE Dinneen Incorporated was not aware of any pending, threatened or past environmental
litigation, proceedings or notices of possible violations of environmental laws or liability or
potential environmental concerns in connection with the site.
When asked about the adjoining properties, Mr. Dinneen stated that there had been a gasoline
UST in the street north of the site and a dispenser pump on the sidewalk that Taylor used to fill
their cars at the dealership. He said that the only connection the pump and dispenser had to the
site was electrical. Mr. Dinneen said that Mecham had the tank removed in 1984 by Hartsook.
Mr. Dinneen indicated that there had been several car dealerships, offices and a variety of
businesses in the adjoining properties over the years. Mr. Dinneen stated that the northwest
adjoining property used to be a dry cleaner, Cheyenne Steam Laundry, and the site was part of
the Voluntary Remediation Program. The dry cleaning building was torn down in 1993 or 1994
after which the current bank was built. He also indicated that the east corner of the north
adjoining property may have been a gas station at one time.
Interview with Ms. Jennifer Escobedo
Terracon conducted a personal interview with Ms. Jennifer Escobedo, WSHIIP Program
Manager for Wyoming Senior Citizens Inc., to inquire about current use of the property and
known environmental conditions. Wyoming Senior Citizens Inc. is the current occupant of 413 W
18th St (Suite D of the Dinneen Building). Ms. Escobedo has been associated with the site for
nine months, but stated that Wyoming Senior Citizens Inc. had been the occupant since 1993.
The current use of the space is as an office providing services for seniors in the state. Ms.
Escobedo was not aware of environmental concerns associated with the site.
Interview with Ms. Sara Flanary and Vanessa Young
Terracon conducted a personal interview with Ms. Sarah Flanary, Quality Assurance
Coordinator for Home Instead Senior Care, and Ms. Vanessa Young, Staffing Coordinator for
Home Instead Senior Care, to inquire about current use of the property and known
environmental conditions. Home Instead Senior Care is the current occupant of 1723 Thomes
Ave, Suite A (Suite A of the Dinneen Building). Ms. Flanary has been associated with the site for
1.5 years and Ms. Young has been associated with the site for 2.5 years. Home Instead Senior
Responsive ■ Resourceful ■ Reliable
19
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Care has been the occupant of Suite A since 2007. The current use of the space is as an office
for managing in-home care for seniors. Ms. Flanary nor Ms. Young were aware of
environmental concerns associated with the site.
Interview with Mr. Kyle Hoffdahl
Terracon conducted a personal interview with Mr. Kyle Hoffdahl of Domonkos Law Office to
inquire about current use of the property and known environmental conditions. Domonkos Law
Office is the current occupant of 419 W 18th St (Suite C of the Dinneen Building). Mr. Hoffdahl
has been associated with the site since December 2010, and Domonkos Law Office has been
the occupant of Suite C since December 2010. The current use of the space is as an office for
providing law services. Mr. Hoffdahl was not aware of environmental concerns associated with
the site.
The occupant of Suite B was unable to be contacted for an interview.
3.9
Prior Report Review
Previous environmental reports for the site were not provided by the client to Terracon for
review.
3.10
Historical Use Information Summary
Based on a review of the historical information, the site was developed prior to 1883. Previous
uses of the site included blacksmithing; painting; laundry and dry cleaning; creamery; filling
station; vulcanizing; and auto sales, service, repair, and painting. The east portion of the
existing building on site was thought to have been constructed between 1915 and 1920 and was
used for automobile sales, service, repair, and painting. The west portion of the existing building
on-site was constructed in approximately 1961 and was used for automobile sales, service,
repair and painting. The site was purchased by Dinneen in 1989 and the building was renovated
by Dinneen in 1991. Dinneen used the site for automobile sales, service, repair and painting.
The adjoining properties to the north, east, south and west were developed prior to 1883.
Previous uses of the adjoining properties to the north included painting; machine repair; steam
laundry; a filling station; and auto sales, service, and repair. Previous uses of the adjoining
properties to the east included Chinese laundry; photography; tire sales and service; a filling
station; automobile service and repair; and machine repair. Previous uses of the adjoining
properties to the south included Chinese laundry; painting; blacksmithing; auto repair and
machine repair. Previous uses of the adjoining properties to the west included Chinese laundry;
blacksmithing; auto sales, service and repair; machine repair; and dry cleaning. The above
referenced uses of the site and adjoining properties constitute a REC to the site.
Responsive ■ Resourceful ■ Reliable
20
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
4.0
RECORDS REVIEW
Regulatory database information was provided by GeoSearch, a contract information services
company. The purpose of the records review was to identify RECs in connection with the site.
Information in this section is subject to the accuracy of the data provided by the information
services company and the date at which the information is updated, and the scope herein did
not include confirmation of facilities listed as "unmappable" by regulatory databases.
In some of the following subsections, the words up-gradient, cross-gradient and down-gradient
refer to the topographic gradient in relation to the site. As stated previously, the groundwater
flow direction and the depth to shallow groundwater, if present, would likely vary depending
upon seasonal variations in rainfall and the depth to the soil/bedrock interface. Without the
benefit of on-site groundwater monitoring wells surveyed to a datum, groundwater depth and
flow direction beneath the site cannot be directly ascertained.
4.1
Federal and State/Tribal Databases
Listed below are the facility listings identified on federal and state/tribal databases within the
ASTM-required search distances from the approximate site boundaries. Database definition,
descriptions, and the database search report are included in Appendix D.
Federal Databases
Radius
(miles)
Listings
Brownfields
are
real
property,
the
expansion,
redevelopment, or reuse of which may be complicated by
the presence or potential presence of a hazardous
substance, pollutant, or contaminant. Cleaning up and
reinvesting in these properties takes development pressures
off of undeveloped, open land, and both improves and
protects the environment. The United States Environmental
Protection Agency maintains this database to track activities
in the various brown field grant programs including grantee
assessment, site cleanup and site redevelopment.
0.5
0
CERCLIS
CERCLIS is the repository for site and non-site specific
Superfund information in support of the Comprehensive
Environmental Response, Compensation and Liability Act
(CERCLA). This United States Environmental Protection
Agency database contains an extract of sites that have been
investigated or are in the process of being investigated for
potential environmental risk.
0.5
1
DNPL
This database includes sites from the United States
Environmental Protection Agency‟s Final National Priorties
List (NPL) where remedies have proven to be satisfactory or
sites where the original analyses were inaccurate, and the
site is no longer appropriate for inclusion on the NPL, and
final publication in the Federal Register has occurred.
1
0
Database
Description
BF
Responsive ■ Resourceful ■ Reliable
21
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Radius
(miles)
Listings
This database includes site locations where Engineering
and/or Institutional Controls have been identified as part of a
selected remedy for the site as defined by United States
Environmental Protection Agency official remedy decision
documents.
A site listing does not indicate that the
institutional and engineering controls are currently in place
nor will be in place once the remedy is complete; it only
indicates that the decision to include either of them in the
remedy is documented as of the completed date of the
document. Institutional controls are actions, such as legal
controls, that help minimize the potential for human
exposure to contamination by ensuring appropriate land or
resource use. Engineering controls include caps, barriers,
or other device engineering to prevent access, exposure, or
continued migration of contamination.
Site
0
ERNSWY
This National Response Center database contains data on
reported releases of oil, chemical, radiological, biological,
and/or etiological discharges into the environment anywhere
in the United States and its territories. The data comes from
spill reports made to the U.S. Environmental Protection
Agency, U.S. Coast Guard, the National Response Center
and/or the U.S. Department of Transportation.
Site
0
LUCIS
The LUCIS database is maintained by the U.S. Navy and
contains information for former Base Realignment and
Closure (BRAC) properties across the United States.
0.5
0
NFRAP
This database includes sites which have been determined
by the United States Environmental Protection Agency,
following preliminary assessment, to no longer pose a
significant risk or require further activity under CERCLA.
After initial investigation, no contamination was found,
contamination was quickly removed or contamination was
not serious enough to require Federal Superfund action or
NPL consideration.
0.5
1
NLRRCRAG
This database includes RCRA Generator facilities that are
no longer regulated by the United States Environmental
Protection Agency or do not meet other RCRA reporting
requirements.
0.125
0
NLRRCRAT
This database includes RCRA Non-Corrective Action TSD
facilities that are no longer regulated by the United States
Environmental Protection Agency or do not meet other
RCRA reporting requirements. This listing includes facilities
that formerly treated, stored or disposed of hazardous
waste.
0.5
1
NPL
This database includes United States Environmental
Protection Agency (EPA) National Priorities List sites that
fall under the EPA's Superfund program, established to fund
the cleanup of the most serious uncontrolled or abandoned
hazardous waste sites identified for possible long-term
remedial action.
1
0
Database
Description
EC
Responsive ■ Resourceful ■ Reliable
22
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Radius
(miles)
Listings
This database contains sites proposed to be included on the
National Priorities List (NPL) in the Federal Register. The
United States Environmental Protection Agency investigates
these sites to determine if they may present long-term
threats to public health or the environment.
1
0
RCRAC
This database includes hazardous waste sites listed with
corrective action activity in the RCRAInfo system. The
Corrective Action Program requires owners or operators of
RCRA facilities (or treatment, storage, and disposal
facilities) to investigate and cleanup contamination in order
to protect human health and the environment. The United
States Environmental Protection Agency defines RCRAInfo
as the comprehensive information system which provides
access to data supporting the Resource Conservation and
Recovery Act (RCRA) of 1976 and the Hazardous and Solid
Waste Amendments (HSWA) of 1984. RCRAInfo replaces
the data recording and reporting abilities of the Resource
Conservation and Recovery Information System (RCRIS)
and the Biennial Reporting System (BRS).
1
2
RCRAGR08
This database includes sites listed as generators of
hazardous waste (large, small, and exempt) in the
RCRAInfo system.
The United States Environmental
Protection Agency defines RCRAInfo as the comprehensive
information system which provides access to data
supporting the Resource Conservation and Recovery Act
(RCRA) of 1976 and the Hazardous and Solid Waste
Amendments (HSWA) of 1984. RCRAInfo replaces the data
recording and reporting abilities of the Resource
Conservation and Recovery Information System (RCRIS)
and the Biennial Reporting System (BRS). This database
includes sites located in EPA Region 8. This region
includes the following states: Colorado, Montana, North
Dakota, South Dakota, Utah, and Wyoming.
Large Quantity Generators: Generate 1,000 kg or more of
hazardous waste during any calendar month; or Generate
more than 1 kg of acutely hazardous waste during any
calendar month; or Generate more than 100 kg of any
residue or contaminated soil, waste or other debris resulting
from the cleanup of a spill, into or on any land or water, or
acutely hazardous waste during any calendar month; or
Generate 1 kg or less of acutely hazardous waste during
any calendar month, and accumulate more than 1kg of
acutely hazardous waste at any time; or Generate 100 kg or
less of any residue or contaminated soil, waste or other
debris resulting from the cleanup of a spill, into or on any
land or water, of acutely hazardous waste during any
calendar month, and accumulated more than 100 kg of that
material at any time.
Small Quantity Generators: Generate more than 100 and
less than 1000 kilograms of hazardous waste during any
calendar month and accumulate less than 6000 kg of
0.1
3
Database
Description
PNPL
Responsive ■ Resourceful ■ Reliable
23
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Database
Description
Radius
(miles)
Listings
0.5
0
Radius
(miles)
Listings
Site
0
hazardous waste at any time; or Generate 100 kg or less of
hazardous waste during any calendar month, and
accumulate more than 1000 kg of hazardous waste at any
time.
Conditionally Exempt Small Quantity Generators: Generate
100 kilograms or less of hazardous waste per calendar
month, and accumulate 1000 kg or less of hazardous waste
at any time; or Generate one kilogram or less of acutely
hazardous waste per calendar month, and accumulate at
any time: 1 kg or less of acutely hazardous waste; or 100 kg
or less of any residue or contaminated soil, waste or other
debris resulting from the cleanup of a spill, into or on any
land or water, or acutely hazardous waste; or Generate 100
kg or less of any residue or contaminated soil, waste or
other debris resulting from the cleanup of a spill, into or on
any land or water, or acutely hazardous waste during any
calendar month, and accumulate at any time: 1 kg or less of
acutely hazardous waste; or 100 kg or less of any residue or
contaminated soil, waste or other debris resulting from the
cleanup of a spill, into or on any land or water, of acutely
hazardous waste.
RCRAT
This database includes Non-Corrective Action sites listed as
treatment, storage and/or disposal facilities of hazardous
waste in the RCRAInfo system.
The United States
Environmental Protection Agency defines RCRAInfo as the
comprehensive information system which provides access
to data supporting the Resource Conservation and
Recovery Act (RCRA) of 1976 and the Hazardous and Solid
Waste Amendments (HSWA) of 1984. RCRAInfo replaces
the data recording and reporting abilities of the Resource
Conservation and Recovery Information System (RCRIS)
and the Biennial Reporting System (BRS).
State/Tribal Databases
Database
Description
IC
As defined by the Wyoming Department of Environmental
Quality (DEQ), institutional controls are legal or
administrative measures that limit human exposure to
contaminants. Examples include use control areas,
easements, zoning restrictions, and deed notices. They are
intended to bolster the integrity of remedies and minimize
the potential exposure to contamination by limiting land or
resource use. This list of sites with institutional controls in
place is provided by the DEQ‟s Voluntary Remediation
Program.
Responsive ■ Resourceful ■ Reliable
24
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Radius
(miles)
Listings
This listing of active storage tank facilities with
contamination is provided by the Wyoming Department of
Environmental Quality‟s Storage Tank Program (STP).
According to Wyoming Statues 35-11-1414 through 35-111428, the state is responsible for remediation of releases
from regulated underground storage tanks and certain
aboveground storage tanks. The STP rules and regulations
apply to all regulated storage tanks in Wyoming. Storage
tank owners/operators are entitled to the state corrective
action program if they register their tank(s), pay applicable
fees, and complete a minimum site assessment (if
applicable). State management of remediation is optional for
owners; however, almost no tank system owners have
elected to complete cleanup at their expense.
0.5
30
LUSTR08
This database, provided by the United States Environmental
Protection Agency (EPA), contains leaking underground
storage tanks on Tribal lands located in EPA Region 8. This
region includes the following states: Colorado, Montana,
North Dakota, South Dakota, Utah, and Wyoming.
0.5
0
ORPHANS
The Orphan Site listing is provided by the Wyoming
Department of Environmental Quality (DEQ). Under the
Environmental Quality Act “Orphan Sites” are defined as:
Sites where the DEQ determines that there is no viable
party that is responsible for causing or contributing to the
contamination present at the site; Sites where DEQ has
issued a no further action letter, and where there is a
subsequent discovery of contamination which was present
at the site when the no further action letter was issued; Spill
sites, where DEQ determines that the person responsible for
the spill cannot be identified or where DEQ must take
prompt action to prevent hazards to human health or the
environment at a site where a responsible party fails to act
promptly.
0.5
0
ST
This listing contains active and inactive storage tank
facilities regulated by the Wyoming Department of
Environmental Quality‟s Storage Tank Program (STP). The
STP regulates underground storage tanks (USTs) that
contain petroleum or hazardous substances; USTs that are
larger than 110 gallons or 1,100 gallons on a farm, ranch, or
residence; and those that are not heating oil tanks. The
STP regulates aboveground storage tanks (ASTs) only if
they contain gasoline or diesel, and they are used by a fuel
dealer to directly fuel vehicles. The STP does not regulate
septic tanks, water storage tanks, hazardous substance
ASTs, heating oil tanks, bulk plants, oil refineries, interstate
pipeline breakout tanks, or temporary construction ASTs.
0.25
29
SWF
This listing of permitted solid waste facilities is provided by
the Solid and Hazardous Waste Division (SHWD) of the
Wyoming Department of Environmental Quality.
The
SHWD‟s Solid Waste and Permitting Corrective Action
Program is responsible for permitting the location, design,
0.5
2
Database
Description
LST
Responsive ■ Resourceful ■ Reliable
25
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Database
Description
Radius
(miles)
Listings
construction, operation, monitoring, closure and post-closure
care and remediation of solid waste management facilities.
The solid waste facilities that are regulated by this program
include local community landfills (both operating and
closed), municipal waste baling stations and transfer
facilities, industrial waste landfills, industrial waste treatment
facilities and units, and used oil storage facilities.
USTR08
This database, provided by the United States Environmental
Protection Agency (EPA), contains underground storage
tanks on Tribal lands located in EPA Region 8. This region
includes the following states: Colorado, Montana, North
Dakota, South Dakota, Utah, and Wyoming.
0.25
0
VRPBF
Wyoming‟s Voluntary Remediation Program (VRP) was
created by the Wyoming Legislature in 2000 to create new
opportunities, procedures, standards and incentives for
voluntary remediation of contaminated properties. In order
to encourage more people to participate in the VRP, the
Wyoming Department of Environmental Quality (DEQ)
obtained a grant from the U.S. Environmental Protection
Agency to provide technical assistance (Brownfields
Assistance) at brownfield properties that are eligible to
participate in Wyoming‟s VRP. This DEQ listing contains
both VRP and Brownfield properties.
0.5
8
In addition to the above ASTM-required listings, Terracon reviewed other federal, state, local,
and proprietary databases provided by the database firm. A list of the additional reviewed
databases is included in the regulatory database report included in Appendix D.
The following table summarizes the site-specific information provided by the database and/or
gathered by this office for identified facilities. Facilities are listed in order of proximity to the site.
Additional discussion for selected facilities follows the summary table.
Listed Facilities
Facility Name And Location
Mecham Pontiac Buick Jeep
1720 Pioneer Avenue
Sam Menkin
408 West 18th
Dinneen Lincoln Mercury
400 West 16th Street
Former Wortham Machinery Co.
517 W. 17th Street
Eagles Aerie # 128
Responsive ■ Resourceful ■ Reliable
Estimated
Distance/Direction/Gradient
Site
Database Listings
WYST, WYLST
North Adjoining Property
WYST
Approximately 0.060 miles S
Approximately 0.060 miles SW
WYST,
USRCRAGR08,
WYVRPBF
WYVRPBF
Approximately 0.070 miles S
WYLST
26
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Facility Name And Location
Estimated
Distance/Direction/Gradient
1600 Thomes Avenue
Morris A. Wolin Trust
522 West 16th Street
Checker-Yellow Cab Company
1808 O'Neil Avenue
Flack Outdoor Advertising, Inc.
423 West 16th Street
Goodyear Auto Service Center #81
401 West 16 Street
GSA Motor Pool
501 West Lincolnway
Laramie County Detention Center
1910 Pioneer
Fuel Specialists Corporation
519 West 16th Street P.O. Box
445
Haller's Repair
521 W. Lincolnway
Laramie County Government
19th and Carey Avenue
Suburban Propane
601 West Lincolnway
Union Pacific Railroad
201 West 17Th Street
Rutledge Radiator and Welding
621 West Lincolnway
AandI MVMS
723 West 19th Street
Cheyenne Newspapers, Inc.
702 West Lincolnway
Headquarters Fire Station
706 West 19th Street
Parking Lot Rocky Mountain FSB
2002 Carey Avenue
709 West Lincolnway, Cheyenne
709 West Lincolnway
Cheyenne Main
1919 Capitol Avenue 3D
Firestone Store #4855/010456
2001 Carey Avenue
DownTown Conoco
1802 Central Avenue
Snyder Substation
Responsive ■ Resourceful ■ Reliable
Database Listings
WYST
Approximately 0.080 miles S
WYST
Approximately 0.100 miles W
WYST
Approximately 0.100 miles S
WYST
Approximately 0.100 miles S
Approximately 0.100 miles S
WYST,
USRCRAGR08
WYST, WYLST
Approximately 0.100 miles NW
WYST
Approximately 0.110 miles S
WYLST
Approximately 0.110 miles S
USRCRAGR08
Approximately 0.110 miles N
WYST, WYLST
Approximately 0.130 miles S
WYST, WYLST
Approximately 0.130 miles E
USNLRRCRAT
Approximately 0.160 miles SW
WYST
Approximately 0.180 miles W
WYST, WYLST
Approximately 0.180 miles SW
WYST, WYLST
Approximately 0.180 miles W
WYST, WYLST
Approximately 0.180 miles N
WYST, WYLST
Approximately 0.190 miles SW
WYVRPBF
Approximately 0.190 miles NE
WYST, WYLST
Approximately 0.190 miles N
WYST
Approximately 0.200 miles NE
WYST
Approximately 0.210 miles W
WYST, WYLST
27
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Facility Name And Location
Estimated
Distance/Direction/Gradient
Database Listings
800 West 18th Street
Cheyenne Station
121 West 15th Street
Greyhound Lines, Inc. #8203
1503 Capitol Avenue
UPRR Railroad Facility
121 W 15th St.
Uprr Yard (Vulcan Chem Spill)
121 West 15Th St
Emerson Building Emergency
Power
2001 Capitol Avenue
Cheyenne Landfill (10.080)
City Engineers Office, 2101 O'Neil,
Cheyenne Transfer Station
(50.217)
2101 O''Neil Avenue
Jerrys Toppers and Custom
Upholstery
803 West Lincolnway
Dafc/Mvms
801 West 20th Street
Steel Creek Trailer Sales
801 West 19th Street
Union Pacific Railroad
105 West 15th Street
Big D #32
820 West Lincolnway
Cheyenne City Gas Co
Snyder Ave & W 18Th St, Se
Corner
Royal Glass
200 East 17th
Fleet Maintenance Department
1500 Snyder Avenue
Hardee's Restaurant
216 E. Lincolnway
Deluxe Cleaners & Tailors
1614 House Ave.
Kum and Go #956
215 East Lincolnway
Lincolnway Fast Break
300 East Lincolnway
Responsive ■ Resourceful ■ Reliable
Approximately 0.220 miles SE
WYST, WYLST
Approximately 0.220 miles SE
WYST
Approximately 0.220 miles SE
WYVRPBF
Approximately 0.220 miles SE
USRCRAC
Approximately 0.230 miles N
WYST
Approximately 0.240 miles NW
WYSWF
Approximately 0.240 miles NW
WYSWF
Approximately 0.240 miles SW
WYST, WYLST
Approximately 0.250 miles W
WYST
Approximately 0.250 miles W
WYST, WYLST
Approximately 0.250 miles SE
WYST, WYLST
Approximately 0.260 miles SW
WYLST
Approximately 0.270 miles SW
USCERCLIS, USNFRAP
Approximately 0.290 miles E
WYLST
Approximately 0.310 miles SW
WYLST
Approximately 0.320 miles E
WYVRPBF
Approximately 0.330 miles E
WYVRPBF
Approximately 0.330 miles E
WYLST
Approximately 0.370 miles E
WYLST
28
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Facility Name And Location
Snyder Food and Gas
2100 Snyder Avenue
E-Z Auto Sales
1001 West 16th Street
Barrett Building Emergency Power
2301 Central Avenue
Intermountain Safety
1122 West 19th Street
Mesic's Conoco
1131 West Lincolnway
Cheyenne Village Inn
411 E. 16th Street
2500 Block of Thomes Ave,
Cheyenne
2500 Block of Thomes
Amerigas
1000 West 23rd Street
Amerigas Cheyenne
1021 West 23rd Street
Cheyenne Regional Medical
Center
300 East 23rd Street
Vacant Garage - 502 East
Lincolnway
502 East Lincolnway
Glacier Park Property - Cheyenne
West Of B.N. Rr Yard 1201 W
27Th St
Estimated
Distance/Direction/Gradient
Approximately 0.370 miles W
Database Listings
WYLST
Approximately 0.380 miles SW
WYLST
Approximately 0.420 miles N
WYLST
Approximately 0.440 miles W
WYLST
Approximately 0.450 miles SW
WYLST
Approximately 0.460 miles E
WYVRPBF
Approximately 0.500 miles NW
WYVRPBF
Approximately 0.500 miles W
WYLST
Approximately 0.500 miles W
WYLST
Approximately 0.500 miles N
WYLST
Approximately 0.500 miles E
WYLST
Approximately 0.790 miles W
USRCRAC
Mecham Pontiac Buick Jeep, 1720 Pioneer Ave
The facility was located on the northeast corner of the site. Mecham Pontiac Buick Jeep was
listed in the Storage Tank and Leaking Storage Tank databases. Mr. Adrian Ducharme, WDEQSHWD Storage Tank Program District 1 Supervisor, was contacted about the site. Mr.
Ducharme stated that the facility is a resolved contaminated site in respect to gasoline tanks
with contamination concentrations below WDEQ clean-up levels. Two 1,000-gallon gasoline
USTs were removed on February 14, 1989, and there was reportedly no evidence of a
confirmed release of contaminants. One 560-gallon UST was to be filled with an inert material
and left in the ground. Based upon the current regulatory status of the site, this facility is a
historic REC.
Sam Menkin, 408 West 18th
This facility is located in the north adjoining property and is listed in the Storage Tank Program.
Mr. Adrian Ducharme, WDEQ-SHWD Storage Tank Program District 1 Supervisor, was
Responsive ■ Resourceful ■ Reliable
29
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
contacted about the facility and he stated that two 1,000-gallon gasoline USTs were last used in
1989 and both tanks were removed from the ground. He also said that there was no
confirmation of a release from the gasoline USTs at the facility. Since USTs were used at the
facility, this facility is a historic REC.
2500 Block of Thomes Ave, Cheyenne
This facility is located within 0.5 miles of the site and is listed in the Voluntary Remediation
Program and Brownfield Sites database. Ms. Cindi Martinez of the WDEQ-SHWD Voluntary
Remediation Program was contacted about the facility. Ms. Martinez indicated that the facility is
the Cheyenne PCE Plume. The facility is located topographically up-gradient and within the
regulatory search radius and thus constitutes a REC.
Glacier Park Property-Cheyenne, West of B.N. RR Yard 1201 W 27th St
This facility is located within 1 mile of the site and is listed in the Resource Conservation &
Recovery Act-Corrective Action Facilities database. The facility is listed as “Not a Generator” in
the database report. Ms. Cindi Martinez of the WDEQ-SHWD Voluntary Remediation Program
was contacted about the facility. Ms. Martinez did not have information readily available about
the facility. This facility is located topographically up-gradient of the site and within the
regulatory search radius and thus and indicates a REC.
Mr. John Dinneen had mentioned during his interview that the northwest adjoining property was
a contaminated site that was part of the Voluntary Remediation Program (VRP); however, this
site did not appear in the database search. Ms. Cindi Martinez of the WDEQ-SHWD Voluntary
Remediation Program was contacted about this facility. Ms. Martinez stated that work was not
conducted under the VRP (and would not show in a database search) because the property
changed ownership as a result of foreclosure so the acquiring bank was not held responsible for
the contamination. Additional information about the site was not reasonably ascertainable at the
time of this report and thus the site constitutes a REC at this time.
The remaining facilities listed in the database report do not appear to represent RECs to the site
at this time based upon regulatory status, apparent topographic gradient, and/or relative
distance from the site.
Unmapped facilities are those that do not contain sufficient address or location information to
evaluate the facility listing locations relative to the site. The report listed two facilities in the
unmapped section. Determining the location of unmapped facilities is beyond the scope of this
assessment; however, none of these facilities were identified as the site or adjacent properties.
These facilities are listed in the database report in Appendix D.
Responsive ■ Resourceful ■ Reliable
30
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
4.2
Local Agency Inquiries
4.2.1 Fire Department
The City of Cheyenne Fire & Rescue Department was contacted by phone regarding
environmental records or information indicating environmental concerns for the site. Mr. Mark
Norford, Division Chief of Prevention and Fire Marshall, stated that the fire department records
for the site for the last five years did not indicate calls pertaining to hazardous substances.
Additionally, Mr. Norford said that he does not recall calls to the site pertaining to hazardous
substances in the last 8 years.
4.2.2 Local/Regional Pollution Control Agency
The Wyoming Department of Environmental Quality-Solid & Hazardous Waste Division (WDEQSHWD was contacted by phone regarding environmental records for the site. The information
obtained from this agency about the site is summarized in Section 4.1.
4.3
Records Review Summary
Selected federal and state environmental regulatory databases as well as responses from state
and local regulatory agencies were reviewed. Several facilities were identified in the regulatory
databases. Based on distance, environmental setting and/or facility characteristics, the
northeast corner of the site, the northwest adjoining property and three topographically upgradient facilities constitute RECs to the site.
5.0
SITE RECONNAISSANCE
5.1
General Site Information
Information contained in this section is based on a visual reconnaissance conducted while
walking through the site and the accessible interior areas of structures, if any, located on the
site. Exhibit 2 in Appendix A is a Site Diagram of the site. Photo documentation of the site at the
time of the visual reconnaissance is provided in Appendix E. Credentials of the individuals
planning and conducting the site visit are included in Appendix F.
Responsive ■ Resourceful ■ Reliable
31
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
General Site Information
Site Reconnaissance
Field Personnel
Carrie Harns
Reconnaissance Date
April 30, 2013
Weather Conditions
Weather
Site Contact/Title
John Dinneen / General Manager
Building Description
Building
Building
Identification
Use
Dinneen Building (includes
basement and roof top
parking deck)
Offices, storage
Approx.
Construction
Date
1920 (east),
1960 (west)
Number
Approx.
of
Stories
Size (ft²)
1
69,000
Site Utilities
5.2
Drinking Water
City of Cheyenne Board of Public Utilities
Wastewater
City of Cheyenne Board of Public Utilities
Overview of Current Site Occupants and Operations
The site includes one building (Dinneen Building) currently used as offices and for storage. The
building includes a basement of approximately 24,000 square feet, a first floor of approximately
30,000 square feet, and a roof top parking deck of approximately 15,000 square feet on the
west portion of the building. The site also includes two parking lots. The west parking lot is used
for paid monthly parking and the east parking lot is rented to Sidles for their parking needs. The
northwest portion of the first floor of the building includes four office suites that are occupied by
Home Instead Senior Care (Suite A), a real estate office (Suite B), Domonkos Law Office (Suite
C), and Wyoming Senior Citizens Inc. (Suite D).
5.3
Site Observations
The following table summarizes site observations and interviews.
(designated by an “X”) are discussed in more detail following the table.
Responsive ■ Resourceful ■ Reliable
Affirmative responses
32
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Site Characteristics
Category
Item or Feature
Observed
Emergency generators
Elevators
Site Operations,
Processes, and
Equipment
Air compressors
X
Hydraulic lifts
X
Dry cleaning
Photo processing
Ventilation hoods and/or incinerators
Waste treatment systems and/or water treatment
systems
Heating and/or cooling systems
Other processes or equipment
Aboveground
Chemical or
Waste Storage
X
Aboveground storage tanks
Drums, barrels and/or containers  5 gallons
X
MSDS
Underground storage tanks or ancillary UST
equipment
Underground
Chemical or
Waste Storage,
Drainage or
Collection
Systems
Sumps, cisterns, catch basins and/or dry wells
X
Grease traps
Septic tanks and/or leach fields
Oil/water separators
X
Pipeline markers
Interior floor drains
Electrical
Transformers/
PCBs
X
Transformers and/or capacitors
Other equipment
Responsive ■ Resourceful ■ Reliable
33
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
Category
Item or Feature
Observed
Stressed vegetation
Stained soil
Stained pavement or similar surface
Leachate and/or waste seeps
Trash, debris and/or other waste materials
Releases or
Potential Releases
Dumping or disposal areas
Construction/demolition debris and/or dumped fill
dirt
Surface water discoloration, odor, sheen, and/or
free floating product
Strong, pungent or noxious odors
Exterior pipe discharges and/or other effluent
discharges
Surface water bodies
Other Notable Site
Features
Quarries or pits
Wells
Site Operations, Processes, and Equipment
Air compressors
One air compressor was observed in the southeast room of the east portion of the basement.
The air compressor was located on the concrete floor. Minor staining was observed beneath the
air compressor at the time of the site reconnaissance; however, the staining appeared limited to
the concrete floor.
Hydraulic lifts
Floor penetrations for one hydraulic lift unit were observed during the site reconnaissance. The
lift was located on the west side of the first floor of the east portion of the building. The
penetrations were concrete fills surrounded by metal. The unit appeared to have subsurface
components. According to Mr. Dinneen, the unit had subsurface components, but has not been
in the building since at least 1989. No evidence of hydraulic fluid releases was observed from
the lift at the time of the site visit. Information about the status of the subgrade hydraulic oil
tanks was not readily accessible and thus constitutes a REC.
Other processes or equipment
Floor markings for six aboveground electric hoists were evident during the site reconnaissance.
The hoists were located throughout the first floor of the east portion of the building. Floor
markings for an alignment machine were located on the north end of the first floor of the east
portion of the building. A car exhaust system was observed running along the floor drains on the
Responsive ■ Resourceful ■ Reliable
34
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
first floor of the east portion of the building. Floor markings for a paint booth were located in the
southwest end of the basement of the west portion of the building. A steam cleaning machine
was located in the southwest corner of the basement of the west portion of the building. Several
unidentified floor cuts and floor penetrations were evident throughout the building. Evidence of
releases from these processes or equipment was not observed at the time of the site visit.
However, the soil beneath the unidentified floor cuts could not be observed and constitutes a
REC to the site.
Aboveground Chemical or Waste Storage
Drums, barrels, and/or containers  5 gallons
Three empty 55-gallon plastic drums were observed in the southwest corner of the west portion
of the basement of the building at the site. Surficial staining was not observed on the drums or
on the concrete in the vicinity of the drums.
Underground Chemical or Waste Storage, Drainage or Collection Systems
Sumps, cisterns, catch basins and/or dry wells
Evidence of sumps with pumps was observed throughout the basement during the site
reconnaissance. Two groundwater sumps and one sanitary sewer sump were located in the
basement of the east portion of the building. One storm water sump and one sanitary sewer
sump were located in the southwest corner of the west portion of the basement. Based on
information from Mr. Dinneen that these sumps historically contained only water, the sumps do
not constitute a REC to the site.
Oil/water separators
Two oil/water separators were observed during the site reconnaissance; one was located on the
first floor of the east portion of the building and the other was located in the basement of the
west portion of the building. According to Mr. John Dinneen, the oil/water separators were
installed prior to 1989, and were used primarily for collecting floor washings with oil residue. The
oil/water separators receive water from the floor drains and discharge to the sanitary sewer
system. The condition of the oil/water separators, the use of the oil/water separators prior to
1989, and the current amount of product in the tank are unknown. The maintenance record of
the oil/water separators was not available. The oil/water separators constitute a REC to the site.
Interior floor drains
Interior floor drains were observed at the following site locations: southwest side of the
basement of the west portion of the building, first floor ramp exiting to the south, and north and
south sides of the east portion of the first floor. The floor drains on the north side of the east
portion of the first floor each contain a mini sump. According to Mr. John Dinneen, some of the
floor drains discharge to the oil/water separators and then the sanitary sewer, and some of the
floor drains discharge directly to the sanitary sewer. Evidence of staining or other releases to
the floor drains was not observed during the site reconnaissance.
Responsive ■ Resourceful ■ Reliable
35
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
5.4
Site Reconnaissance Summary
Based on site reconnaissance, RECs were identified associated with the current site operations
including a former underground hydraulic hoist, oil/water separators, and unidentified floor cuts
and penetrations.
6.0
ADJOINING PROPERTY RECONNAISSANCE
Visual observations of adjoining properties (from site boundaries) are summarized below.
Adjoining Properties
Direction
Description
th
500 W 18 St: Security First Bank
North
First Interstate Bank Parking
1810 Pioneer Ave: Vacant
th
314 W 18 St: McGee, Hearne & Piaz, LLP
th
325 W 18 St: Offices
East
1712 Pioneer Ave: Offices
1715 Pioneer Ave: Plush Cue Family Billiards
th
322 W 17 St: Cheyenne Transitional Center
Downtown Parking Structure (City)
th
400 W 17 St: Sidles Co Complete Auto Parts Store
th
South
406 W 17 St: Sidles Co
th
408 W 17 St: Advance Cash Services
th
Parking lot (south of W 17 St)
1620 Thomes Ave: Wyoming Trophy & Engraving
th
West
504 W 17 St: Downtown West Building
Parking Lot
Indications of RECs were not visually observed with the current use of the adjoining properties.
7.0
ADDITIONAL SERVICES
Per the agreed scope of services specified in the proposal, the following additional services
were conducted: Asbestos Survey. Please refer to the IHI Environmental Asbestos-Containing
Material Field Survey Report (IHI Project No. AM137527) for the findings of these assessments.
Responsive ■ Resourceful ■ Reliable
36
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
April 30, 2013 ■ Terracon Project No. 24137705
8.0
DECLARATION
I, Clay Muirhead, P.E., declare that, to the best of my professional knowledge and belief, I meet
the definition of Environmental Professional as defined in Section 312.10 of 40 CFR 312; and I
have the specific qualifications based on education, training, and experience to assess a
property of the nature, history, and setting of the site. I have developed and performed the All
Appropriate Inquiries in conformance with the standards and practices set forth in 40 CFR Part
312.
Responsive ■ Resourceful ■ Reliable
37
APPENDIX A
EXHIBIT 1 – TOPOGRAPHIC MAP
EXHIBIT 2 – SITE DIAGRAM
EXHIBIT 3 – BUILDING DIAGRAM-FIRST FLOOR
EXHIBIT 4 – BUILDING DIAGRAM-BASEMENT
APPENDIX B
DESCRIPTION OF TERMS AND ACRONYMS
Description of Selected General Terms and Acronyms
Term/Acronym
ACM
AHERA
AST
BGS
BTEX
CERCLA
CERCLIS
CESQG
CFR
DOT
Description
Asbestos Containing Material. Asbestos is a naturally occurring mineral, three varieties of which (chrysotile, amosite, crocidolite) have been
commonly used as fireproofing or binding agents in construction materials. Exposure to asbestos, as well as ACM, has been documented to
cause lung diseases including asbestosis (scarring of the lung), lung cancer and mesothelioma (a cancer of the lung lining).
Regulatory agencies have generally defined ACM as a material containing greater that one (1) percent asbestos, however some states (e.g.
California) define ACM as materials having 0.1% asbestos. In order to define a homogenous material as non-ACM, a minimum number of
samples must be collected from the material dependent upon its type and quantity. Homogenous materials defined as non-ACM must either
have 1) no asbestos identified in all of its samples or 2) an identified asbestos concentration below the appropriate regulatory threshold.
Asbestos concentrations are generally determined using polarized light microscopy or transmission electron microscopy. Point counting is an
analytical method to statistically quantify the percentage of asbestos in a sample. The asbestos component of ACM may either be friable or
non-friable. Friable materials, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure and have a higher potential for
a fiber release than non-friable ACM. Non-friable ACM are materials that are firmly bound in a matrix by plastic, cement, etc. and, if handled
carefully, will not become friable.
Federal and state regulations require that either all suspect building materials be presumed ACM or that an asbestos survey be performed
prior to renovation, dismantling, demolition, or other activities that may disturb potential ACM. Notifications are required prior to demolition
and/or renovation activities that may impact the condition of ACM in a building. ACM removal may be required if the ACM is likely to be
disturbed or damaged during the demolition or renovation. Abatement of friable or potentially friable ACM must be performed by a licensed
abatement contractor in accordance with state rules and NESHAP. Additionally, OSHA regulations for work classification, worker training and
worker protection will apply.
Asbestos Hazard Emergency Response Act
Above Ground Storage Tanks. ASTs are generally described as storage tanks less than 10% of which are below ground (i.e., buried). Tanks
located in a basement, but not buried, are also considered ASTs. Whether, and the extent to which, an AST is regulated, is determined on a
case-by-case basis and depends upon tank size, its contents and the jurisdiction of its location.
Below Ground Surface
Benzene, Toluene, Ethylbenzene, and Xylenes. BTEX are VOC components found in gasoline and commonly used as analytical indicators of
a petroleum hydrocarbon release.
Comprehensive Environmental Response, Compensation and Liability Act (a.k.a. Superfund). CERCLA is the federal act that regulates
abandoned or uncontrolled hazardous waste sites. Under this Act, joint and several liability may be imposed on potentially responsible
parties for cleanup-related costs.
Comprehensive Environmental Response, Compensation and Liability Information System. An EPA compilation of sites having suspected or
actual releases of hazardous substances to the environment. CERCLIS also contains information on site inspections, preliminary
assessments and remediation of hazardous waste sites. These sites are typically reported to EPA by states and municipalities or by third
parties pursuant to CERCLA Section 103.
Conditionally exempt small quantity generators.
Code of Federal Regulations
U.S. Department of Transportation
Description of Selected General Terms and Acronyms (cont.)
Term/Acronym
EPA
ERNS
ESA
FRP
Hazardous
Substance
Hazardous
Waste
ILP
LQG
LUST
MCL
MSDS
NESHAP
NFRAP
NOV
NPDES
NPL
OSHA
PACM
Description
U.S. Environmental Protection Agency
Emergency Response Notification System. An EPA-maintained federal database which stores information on notifications of oil discharges
and hazardous substance releases in quantities greater than the applicable reportable quantity under CERCLA. ERNS is a cooperative datasharing effort between EPA, DOT, and the National Response Center.
Environmental Site Assessment
Fiberglass Reinforced Plastic
As defined under CERCLA, this is (A) any substance designated pursuant to section 1321(b)(2)(A) of Title 33, (B) any element, compound,
mixture, solution, or substance designated pursuant to section 9602 of this title; (C) any hazardous waste having characteristics identified
under or listed pursuant to section 3001 of the Solid Waste Disposal Act (with some exclusions); (D) any toxic pollutant listed under section
1317(a) of Title 33; (E) any hazardous air pollutant listed under section 112 of the Clean Air Act; and (F) any imminently hazardous chemical
substance or mixture with respect to which the EPA Administrator has taken action under section 2606 of Title 15. This term does not
include petroleum, including crude oil or any fraction thereof which is not otherwise listed as a hazardous substance under subparagraphs
(A) through (F) above, and the term include natural gas, or synthetic gas usable for fuel (or mixtures of natural gas and such synthetic gas).
This is defined as having characteristics identified or listed under section 3001 of the Solid Waste Disposal Act (with some exceptions).
RCRA, as amended by the Solid Waste Disposal Act of 1980, defines this term as a “solid waste, or combination of solid wastes, which
because of its quantity, concentration, or physical, chemical, or infectious characteristics may (A) cause, or significantly contribute to an
increase in mortality or an increase in serious irreversible, or incapacitating reversible illness; or (B) pose a substantial present or potential
hazard to human health or the environment when improperly treated, stored, transported, or disposed of, or otherwise managed.”
Innocent Landowner/Operator Program
Large quantity generators.
Leaking Underground Storage Tank. This is a federal term set forth under RCRA for leaking USTs. Some states also utilize this term.
Maximum Contaminant Level. This Safe Drinking Water concept (and also used by many states as a ground water cleanup criteria) refers
to the limit on drinking water contamination that determines whether a supplier can deliver water from a specific source without treatment.
Material Safety Data Sheets. Written/printed forms prepared by chemical manufacturers, importers and employers which identify the
physical and chemical traits of hazardous chemicals under OSHA‟s Hazard Communication Standard.
National Emissions Standard for Hazardous Air Pollutants (Federal Clean Air Act). This part of the Clean Air Act regulates emissions of
hazardous air pollutants.
Facilities where there is “No Further Remedial Action Planned,” as more particularly described under the Records Review section of this
report.
Notice of Violation. A notice of violation or similar citation issued to an entity, company or individual by a state or federal regulatory body
indicating a violation of applicable rule or regulations has been identified.
National Pollutant Discharge Elimination System (Clean Water Act). The federal permit system for discharges of polluted water.
National Priorities List, as more particularly described under the Records Review section of this report.
Occupational Safety and Health Administration or Occupational Safety and Health Act
Presumed Asbestos-Containing Material. A material that is suspected of containing or presumed to contain asbestos but which has not
been analyzed to confirm the presence or absence of asbestos.
Description of Selected General Terms and Acronyms (cont.)
Term/Acronym
PCB
pCi/l
PLM
PST
Radon
RCRA
RCRA
Generators
RCRA
CORRACTS/TS
Ds
RCRA
NonCORRACTS/TS
Ds
RCRA
Violators List
RCRIS
REC
SCL
Description
Polychlorinated Biphenyl. A halogenated organic compound commonly in the form of a viscous liquid or resin, a flowing yellow oil, or a
waxy solid. This compound was historically used as dielectric fluid in electrical equipment (such as electrical transformers and capacitors,
electrical ballasts, hydraulic and heat transfer fluids), and for numerous heat and fire sensitive applications. PCB was preferred due to its
durability, stability (even at high temperatures), good chemical resistance, low volatility, flammability, and conductivity. PCBs, however, do
not break down in the environment and are classified by the EPA as a suspected carcinogen. 1978 regulations, under the Toxic
Substances Control Act, prohibit manufacturing of PCB-containing equipment; however, some of this equipment may still be in use today.
Pico Curies per Liter of Air. Unit of measurement for Radon and similar radioactive materials.
Polarized Light Microscopy (see ACM section of the report, if included in the scope of services)
Petroleum Storage Tank. An AST or UST that contains a petroleum product.
A radioactive gas resulting from radioactive decay of naturally-occurring radioactive materials in rocks and soils containing uranium, granite,
shale, phosphate, and pitchblende. Radon concentrations are measured in Pico Curies per Liter of Air. Exposure to elevated levels of
radon creates a risk of lung cancer; this risk generally increases as the level of radon and the duration of exposure increases. Outdoors,
radon is diluted to such low concentrations that it usually does not present a health concern. However, radon can accumulate in building
basements or similar enclosed spaces to levels that can pose a risk to human health. Indoor radon concentrations depend primarily upon
the building's construction, design and the concentration of radon in the underlying soil and ground water. The EPA recommended annual
average indoor “action level” concentration for residential structures is 4.0 pCi/l.
Resource Conservation and Recovery Act. Federal act regulating solid and hazardous wastes from point of generation to time of disposal
(„cradle to grave”). 42 U.S.C. 6901 et seq.
The RCRA generators list is part of the RCRIS database maintained by EPA and lists facilities that generate hazardous waste as part of
their normal business operations, as more particularly defined under Section 4.1 of this report.
The USEPA maintains a database of RCRA facilities associated with treatment, storage, and disposal (TSD) of hazardous materials which
are undergoing “corrective action”. A “corrective action” order is issued when there is a release of hazardous waste or constituents into the
environment from a RCRA facility.
The RCRA Non-CORRACTS/TSD Database is a compilation by the USEPA of facilities which report storage, transportation, treatment, or
disposal of hazardous waste. Unlike the RCRA CORRACTS/TSD database, the RCRA Non-CORRACTS/TSD database does not include
RCRA facilities where corrective action is required.
RAATS. RCRA Administrative Actions Taken. RAATS information is now contained in the RCRIS database and includes records of
administrative enforcement actions against facilities for noncompliance.
Resource Conservation and Recovery Information System, as defined in the Records Review section of this report.
Recognized Environmental Conditions” are defined by ASTM E1527-05 as “the presence or likely presence of any hazardous substances or
petroleum products on a property under conditions that indicate an existing release, a past release, or a material threat of release of any
hazardous substances or petroleum products into structures on the property or into the ground, ground water, or surface water of the
property. The term includes hazardous substances or petroleum products even under conditions of compliance with laws. The term is not
intended to include de minimis conditions that generally do not present a threat to human health or the environment and that generally
would not be the subject of an enforcement action if brought to the attention of appropriate governmental agencies.”
State “CERCLIS” List (see SPL /State Priority List, below).
Description of Selected General Terms and Acronyms (cont.)
Term/Acronym
SPCC
SPL
SQG
SWF
TPH
TRI
TSCA
USACE
USC
USGS
USNRCS
UST
VCP
VOC
Wetlands
Description
Spill Prevention, Control and Countermeasures. SPCC plans are required under federal law (Clean Water Act and Oil Pollution Act) for any
facility storing petroleum in tanks and/or containers of 55-gallons or more that when taken in aggregate exceed 1,320 gallons. SPCC plans
are also required for facilities with underground petroleum storage tanks with capacities of over 42,000 gallons. Many states have similar
spill prevention programs, which may have additional requirements.
State Priority List. State list of confirmed sites having contamination in which the state is actively involved in clean up activities or is actively
pursuing potentially responsible parties for clean up. Sometimes referred to as a State “CERCLIS” List.
Small quantity generator.
Solid Waste Facility
Total Petroleum Hydrocarbons
Toxic Release Inventory. Routine EPA report on releases of toxic chemicals to the environment based upon information submitted by
entities subject to reporting under the Emergency Planning and Community Right to Know Act.
Toxic Substances Control Act. A federal law regulating manufacture, import, processing and distribution of chemical substances not
specifically regulated by other federal laws (such as asbestos, PCBs, lead-based paint and radon). 15 U.S.C 2601 et seq.
United States Army Corps of Engineers
United States Code
United States Geological Survey
United States Department of Agriculture-Natural Resource Conservation Service
Underground Storage Tank. Most federal and state regulations, as well as ASTM E1527-05, define this as any tank, incl., underground
piping connected to the tank, that is or has been used to contain hazardous substances or petroleum products and the volume of which is
10% or more beneath the surface of the ground (i.e., buried).
Voluntary Cleanup Program
Volatile Organic Compound
Areas that are typically saturated with surface or ground water that creates an environment supportive of wetland vegetation (i.e., swamps,
marshes, bogs). The Corps of Engineers Wetlands Delineation Manual (Technical Report Y-87-1) defines wetlands as areas inundated or
saturated by surface or ground water at a frequency and duration sufficient to support, and that under normal circumstances do support, a
prevalence of vegetation typically adapted for life in saturated soil conditions. For an area to be considered a jurisdictional wetland, it must
meet the following criteria: more than 50 percent of the dominant plant species must be categorized as Obligate, Facultative Wetland, or
Facultative on lists of plant species that occur in wetlands; the soil must be hydric; and, wetland hydrology must be present.
The federal Clean Water Act which regulates “waters of the US,” also regulates wetlands, a program jointly administered by the USACE and
the EPA. Waters of the U.S. are defined as: (1) waters used in interstate or foreign commerce, including all waters subject to the ebb and
flow of tides; (2) all interstate waters including interstate wetlands; (3) all other waters such as intrastate lakes, rivers, streams (including
intermittent streams), mudflats, sandflats, wetlands, sloughs, prairie potholes, wet meadows, playa lakes, or natural ponds, etc., which the
use, degradation, or destruction could affect interstate/ foreign commerce; (4) all impoundments of waters otherwise defined as waters of
the U. S., (5) tributaries of waters identified in 1 through 4 above; (6) the territorial seas; and (7) wetlands adjacent to waters identified in 1
through 6 above. Only the USACE has the authority to make a final wetlands jurisdictional determination.
APPENDIX C
HISTORICAL DOCUMENTATION AND USER QUESTIONNAIRE
historicalinfo.com
New Cheyenne Public Safety Center
W 17th St and Pioneer Ave
Cheyenne, WY
´
2012
HIG Project # 132599
Client Project # 24137705
Approximate Scale 1:6000 (1"=500')
historicalinfo.com
New Cheyenne Public Safety Center
W 17th St and Pioneer Ave
Cheyenne, WY
´
2006
HIG Project # 132599
Client Project # 24137705
Approximate Scale 1:6000 (1"=500')
historicalinfo.com
New Cheyenne Public Safety Center
W 17th St and Pioneer Ave
Cheyenne, WY
´
1994
HIG Project # 132599
Client Project # 24137705
Approximate Scale 1:6000 (1"=500')
historicalinfo.com
New Cheyenne Public Safety Center
W 17th St and Pioneer Ave
Cheyenne, WY
´
1990
HIG Project # 132599
Client Project # 24137705
Approximate Scale 1:9600 (1"=800')
historicalinfo.com
New Cheyenne Public Safety Center
W 17th St and Pioneer Ave
Cheyenne, WY
´
1960
HIG Project # 132599
Client Project # 24137705
Approximate Scale 1:6000 (1"=500')
historicalinfo.com
New Cheyenne Public Safety Center
W 17th St and Pioneer Ave
Cheyenne, WY
´
1947
HIG Project # 132599
Client Project # 24137705
Approximate Scale 1:9600 (1"=800')
APPENDIX D
ENVIRONMENTAL DATABASE INFORMATION
Radius Report
http://www.geo-search.net/QuickMap/index.htm?DataID=Standard0000056685
Click on link above to access the map and satellite view of current property
Target Property:
New Cheyenne Public Safety Center
W 17th St and Pioneer Ave
Cheyenne, Laramie County, Wyoming 82001
Prepared For:
Historical Information Gatherers, Inc.
Order #: 24902
Job #: 56685
Project #: 132599
Date: 04/29/2013
phone: 888-396-0042 · fax: 512-472-9967 · www.geo-search.com
TARGET PROPERTY SUMMARY
New Cheyenne Public Safety Center
W 17th St and Pioneer Ave
Cheyenne, Laramie County, Wyoming 82001
USGS Quadrangle: Cheyenne North, WY
Target Property Geometry:Area
Target Property Longitude(s)/Latitude(s):
(-104.818780, 41.133552), (-104.818780, 41.133552), (-104.819660, 41.133222), (-104.819225, 41.132502),
(-104.818682, 41.132689), (-104.818904, 41.133036), (-104.818815, 41.133062), (-104.818709, 41.132884),
(-104.818424, 41.132991), (-104.818548, 41.133187), (-104.818904, 41.133080), (-104.818958, 41.133187),
(-104.818620, 41.133311), (-104.818780, 41.133543), (-104.818780, 41.133552)
County/Parish Covered:
Laramie (WY)
Zipcode(s) Covered:
Cheyenne WY: 82001, 82007
State(s) Covered:
WY
*Target property is located in Radon Zone 1.
Zone 1 areas have a predicted average indoor radon screening level greater than 4 pCi/L
(picocuries per liter).
This report was designed by GeoSearch to meet or exceed the records search requirements of the All Appropriate Inquires Rule (40 CFR
§312.26) and the current version of the ASTM International E1527, Standard Practice for Environmental Site Assessments: Phase I
Environmental Site Assessment Process or, if applicable, the custom requirements requested by the entity that ordered this report. The
records and databases of records used to compile this report were collected from various federal,state and local governmental entities. It is
the goal of GeoSearch to meet or exceed the 40 CFR §312.26 and E1527 requirements for updating records by using the best available
technology. GeoSearch contacts the appropriate governmental entities on a recurring basis. Depending on the frequency with which a
record source or database of records is updated by the governmental entity, the data used to prepare this report may be updated monthly,
quarterly, semi-annually, or annually.
Disclaimer - The information provided in this report was obtained from a variety of public sources. GeoSearch cannot ensure and makes no
warranty or representation as to the accuracy, reliability, quality, errors occurring from data conversion or the customer’s interpretation of
this report. This report was made by GeoSearch for exclusive use by its clients only. Therefore, this report may not contain sufficient
information for other purposes or parties. GeoSearch and its partners, employees, officers and independent contractors cannot be held
liable for actual, incidental, consequential, special or exemplary damages suffered by a customer resulting directly or indirectly from any
information provided by GeoSearch.
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DATABASE FINDINGS SUMMARY
DATABASE
ACRONYM
LOCA- UNLOCATABLE TABLE
SEARCH
RADIUS
(miles)
FEDERAL
AEROMETRIC INFORMATION RETRIEVAL SYSTEM / AIR FACILITY AIRSAFS
0
0
Target Property
SUBSYSTEM
BIENNIAL REPORTING SYSTEM
BRS
0
0
Target Property
CLANDESTINE DRUG LABORATORY LOCATIONS
CDL
0
0
Target Property
EPA DOCKET DATA
DOCKETS
0
0
Target Property
FEDERAL ENGINEERING INSTITUTIONAL CONTROL SITES
EC
0
0
Target Property
EMERGENCY RESPONSE NOTIFICATION SYSTEM
ERNSWY
0
0
Target Property
FACILITY REGISTRY SYSTEM
FRSWY
0
0
Target Property
HAZARDOUS MATERIALS INCIDENT REPORTING SYSTEM
HMIRSR08
0
0
Target Property
0
0
Target Property
ICISNPDES
0
0
Target Property
MATERIAL LICENSING TRACKING SYSTEM
MLTS
0
0
Target Property
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM
NPDESR08
0
0
Target Property
PCB ACTIVITY DATABASE SYSTEM
PADS
0
0
Target Property
PERMIT COMPLIANCE SYSTEM
PCSR08
0
0
Target Property
RCRA SITES WITH CONTROLS
RCRASC
0
0
Target Property
CERCLIS LIENS
SFLIENS
0
0
Target Property
SECTION SEVEN TRACKING SYSTEM
SSTS
0
0
Target Property
TOXICS RELEASE INVENTORY
TRI
0
0
Target Property
TOXIC SUBSTANCE CONTROL ACT INVENTORY
TSCA
0
0
Target Property
NO LONGER REGULATED RCRA GENERATOR FACILITIES
NLRRCRAG
0
0
Target Property and Adjoining
RESOURCE CONSERVATION & RECOVERY ACT - GENERATOR
RCRAGR08
3
0
Target Property and Adjoining
HISTORICAL GAS STATIONS
HISTPST
0
0
0.2500
BROWNFIELDS MANAGEMENT SYSTEM
BF
0
0
0.5000
COMPREHENSIVE ENVIRONMENTAL RESPONSE,
CERCLIS
1
0
0.5000
INTEGRATED COMPLIANCE INFORMATION SYSTEM (FORMERLY ICIS
DOCKETS)
INTEGRATED COMPLIANCE INFORMATION SYSTEM NATIONAL
POLLUTANT DISCHARGE ELIMINATION SYSTEM
FACILITIES
COMPENSATION & LIABILITY INFORMATION SYSTEM
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DATABASE FINDINGS SUMMARY 1
DATABASE FINDINGS SUMMARY
LOCA- UNLOCATABLE TABLE
SEARCH
RADIUS
(miles)
DATABASE
ACRONYM
LAND USE CONTROL INFORMATION SYSTEM
LUCIS
0
0
0.5000
NO FURTHER REMEDIAL ACTION PLANNED SITES
NFRAP
1
0
0.5000
NO LONGER REGULATED RCRA NON-CORRACTS TSD FACILITIES NLRRCRAT
1
0
0.5000
OPEN DUMP INVENTORY
ODI
0
0
0.5000
RESOURCE CONSERVATION & RECOVERY ACT - TREATMENT,
RCRAT
0
0
0.5000
DELISTED NATIONAL PRIORITIES LIST
DNPL
0
0
1.0000
DEPARTMENT OF DEFENSE SITES
DOD
0
0
1.0000
FORMERLY USED DEFENSE SITES
FUDS
0
0
1.0000
NO LONGER REGULATED RCRA CORRECTIVE ACTION
NLRRCRAC
0
0
1.0000
NATIONAL PRIORITIES LIST
NPL
0
0
1.0000
PROPOSED NATIONAL PRIORITIES LIST
PNPL
0
0
1.0000
RESOURCE CONSERVATION & RECOVERY ACT - CORRECTIVE
RCRAC
2
0
1.0000
RODS
0
0
1.0000
8
0
STORAGE & DISPOSAL FACILITIES
FACILITIES
ACTION FACILITIES
RECORD OF DECISION SYSTEM
SUB-TOTAL
STATE (WY)
SITES WITH INSTITUTIONAL CONTROLS IN PLACE
IC
0
0
Target Property
STORAGE TANKS
ST
29
1
0.2500
LEAKING STORAGE TANKS
LST
30
1
0.5000
ORPHAN SITES
ORPHANS
0
0
0.5000
PERMITTED SOLID WASTE FACILITIES
SWF
2
0
0.5000
8
0
0.5000
69
2
0
0
VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES VRPBF
SUB-TOTAL
TRIBAL
UNDERGROUND STORAGE TANKS ON TRIBAL LANDS
USTR08
0.2500
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DATABASE FINDINGS SUMMARY 2
DATABASE FINDINGS SUMMARY
LOCA- UNLOCATABLE TABLE
SEARCH
RADIUS
(miles)
DATABASE
ACRONYM
LEAKING UNDERGROUND STORAGE TANKS ON TRIBAL LANDS
LUSTR08
0
0
0.5000
OPEN DUMP INVENTORY ON TRIBAL LANDS
ODINDIAN
0
0
0.5000
INDIAN RESERVATIONS
INDIANRES
0
0
1.0000
0
0
77
2
SUB-TOTAL
TOTAL
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DATABASE FINDINGS SUMMARY 3
LOCATABLE DATABASE FINDINGS
ACRONYM
Target
Property
SEARCH
RADIUS
(miles)
1/8 Mile
(> TP)
1/4 Mile
(> 1/8)
1/2 Mile
(> 1/4)
1 Mile
(> 1/2)
> 1 Mile
Total
FEDERAL
AIRSAFS
.0200
0
0
0
0
NS
0
BRS
.0200
0
0
0
0
NS
0
CDL
.0200
0
0
0
0
NS
0
DOCKETS
.0200
0
0
0
0
NS
0
EC
.0200
0
0
0
0
NS
0
ERNSWY
.0200
0
0
0
0
NS
0
FRSWY
.0200
0
0
0
0
NS
0
HMIRSR08
.0200
0
0
0
0
NS
0
ICIS
.0200
0
0
0
0
NS
0
ICISNPDES
.0200
0
0
0
0
NS
0
MLTS
.0200
0
0
0
0
NS
0
NPDESR08
.0200
0
0
0
0
NS
0
PADS
.0200
0
0
0
0
NS
0
PCSR08
.0200
0
0
0
0
NS
0
RCRASC
.0200
0
0
0
0
NS
0
SFLIENS
.0200
0
0
0
0
NS
0
SSTS
.0200
0
0
0
0
NS
0
TRI
.0200
0
0
0
0
NS
0
TSCA
.0200
0
0
0
0
NS
0
NLRRCRAG
.1250
0
0
0
0
NS
0
RCRAGR08
.1250
3
0
0
0
NS
3
HISTPST
.2500
0
0
0
0
NS
0
BF
.5000
0
0
0
0
NS
0
CERCLIS
.5000
0
0
1
0
NS
1
LUCIS
.5000
0
0
0
0
NS
0
NFRAP
.5000
0
0
1
0
NS
1
NLRRCRAT
.5000
0
1
0
0
NS
1
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
LOCATABLE DATABASE FINDINGS 1
LOCATABLE DATABASE FINDINGS
ACRONYM
Target
Property
SEARCH
RADIUS
(miles)
1/8 Mile
(> TP)
1/4 Mile
(> 1/8)
1/2 Mile
(> 1/4)
1 Mile
(> 1/2)
> 1 Mile
Total
ODI
.5000
0
0
0
0
NS
0
RCRAT
.5000
0
0
0
0
NS
0
DNPL
1.000
0
0
0
0
NS
0
DOD
1.000
0
0
0
0
NS
0
FUDS
1.000
0
0
0
0
NS
0
NLRRCRAC
1.000
0
0
0
0
NS
0
NPL
1.000
0
0
0
0
NS
0
PNPL
1.000
0
0
0
0
NS
0
RCRAC
1.000
0
1
0
1
NS
2
RODS
1.000
0
0
0
0
NS
0
3
2
2
1
0
8
.0200
0
0
0
0
NS
0
SUB-TOTAL
STATE (WY)
IC
ST
1
.2500
11
17
0
0
NS
29
LST
1
.5000
4
11
14
0
NS
30
ORPHANS
.5000
0
0
0
0
NS
0
SWF
.5000
0
2
0
0
NS
2
VRPBF
.5000
2
2
4
0
NS
8
17
32
18
0
0
69
SUB-TOTAL
2
TRIBAL
USTR08
.2500
0
0
0
0
NS
0
LUSTR08
.5000
0
0
0
0
NS
0
ODINDIAN
.5000
0
0
0
0
NS
0
INDIANRES
1.000
0
0
0
0
NS
0
0
0
0
0
0
0
20
34
20
1
0
77
SUB-TOTAL
TOTAL
2
NOTES:
NS = NO SEARCH REQUESTED BY CUSTOMER
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
LOCATABLE DATABASE FINDINGS 2
RADIUS MAP
Cheyenne
Cheyenne Regional
Regional Airport
Airport
1 Mile
W 2nd Ave
E Pershing Blvd
e
Av
ve
de r
rA
xw
Ma
e
Av
ell
28
St
E1
20 ’26
9t h
St
E1
’
17&
S
6th
t
1/8 Mile
ley
Av
e
Av
S
th
t
Hw
5
y8
E5
e
e ll
t
th S
US
ay
lnw
co
n
i
L
d
Bra
ss
Ru
E9
E7
m
De
W
1/4 Mile
t
e
Av
Old Happy Jack Rd
S
rd
ans
Ev
21
0
23
&48
&42
2nd
x an
Al e
ve
Hw
y
⊗ 49
1/2 Mile
E2
&19 34
&47
’22 & 37
11
&
8
’
39 ⊗ 45
&40 18
⊗
&
36⊗ 38
2’
&
31’ &
&1 "13
15& ’9
30& 23
3
25’
&
"
5 "
&43 33(
4’
%
%&29
&
"
"
7
’
16
&’&&6 10 24
32& ⊗
&21 14 12
&
41& 35 27
44&
&46
&50
e
St
ve
W
St
at
ve
h
26 t
ou
ym
lA
yA
W
rA
yde
Sn
%
%51
Se
tra
all
Av
e
re
Ca
I 25
n
Ce
Cribbon Ave
Ra
nd
t
th S
in g
Dr
Parsley Blvd
Snyder Ave
E3
rd
St
E 1st St
I 80
Target Property (TP)
&
LST
’
ST
"
"
RCRAGR08
"
⊗
%
%
NLRRCRAT
New Cheyenne Public Safety
Center
W 17th St and Pioneer Ave
Cheyenne, Wyoming
82001

VRPBF
RCRAC
0'
1000'
SWF
(
CERCLIS
SCALE: 1" = 2000'
www.geo-search.com - phone: 888-396-0042 - fax: 512-472-9967
JOB #: 56685 - 4/29/2013
2000'
3000'
RADIUS MAP
nda
l
re
Ca
Ra
E2
ve
rA
ve
0t h
St
E1
9t h
e
Av
ell
e
Av
1/8 Mile
20 ’ 26
17 &’
& 19
’ 22
& 11
’8
E2
xw
Ma
Ave
e
Av
e
Av
28
& 40
se
nt
50
u
Ho
Be
46
ve
1/4 Mile
e
Av
e
Av
&
&
lA
ve
ed
es
om
Th
Re
t
ans
Ev
pit o
rA
e
Av
ee
e il
ve
W
S
rd
48
& 42
Ca
n
Pio
On
rA
yde
Sn
W
2
St
4th
ou
ym
&
t
⊗ 49
23
St
Se
hS
26 t
1/2 Mile
en
enn
nL
Va
W
2nd
yA
l Av
e
St
8th
E1
lo
Dil
18
2 ’
’
&
31
& 1
" 13
15 & ’ 9
30 & &
3
23
25 ’ &
"
"
5
29
& 43
(
%
%
" 7
4 ’& ’"
33
&16 & & 10
24
’
6
t
S
⊗
th
32 &
12
17
W
&
14
&
21
41 & 35 27
44 &
nA
ve
sA
e
Av
e
Am
y
De
& 47
34
37
&
⊗ & 39 ⊗ 45
⊗
36 &
38
ve
5
Hw
y2
10
S
th
8
Hwy
US
te
Sta
W
16
t
Ave
es
Am
y
wa
o ln
Deming
Dr
W
10
th S
t
Sn
Target Property (TP)
&
LST
’
ST
"
"
RCRAGR08
"
⊗
%
%
NLRRCRAT
New Cheyenne Public Safety
Center
W 17th St and Pioneer Ave
Cheyenne, Wyoming
82001

VRPBF
RCRAC
0'
500'
SWF
(
CERCLIS
SCALE: 1" = 1000'
www.geo-search.com - phone: 888-396-0042 - fax: 512-472-9967
JOB #: 56685 - 4/29/2013
1000'
1500'
TOPOGRAPHIC MAP
1 Mile
1/2 Mile
1/4 Mile
1/8 Mile
Target Property (TP)
Quadrangle(s): Cheyenne North
Source: USGS, 1992
New Cheyenne Public Safety
Center
W 17th St and Pioneer Ave
Cheyenne, Wyoming
82001

0'
1000'
SCALE: 1" = 2000'
www.geo-search.com - phone: 888-396-0042 - fax: 512-472-9967
JOB #: 56685 - 4/29/2013
2000'
3000'
REPORT SUMMARY OF LOCATABLE SITES
MAP DATABASE
ID#
NAME
SITE ID#
DISTANCE
FROM SITE
1
ST
0-000012
0.010 SE
1
LST
12
2
ST
3
CITY, ZIP CODE
PAGE
#
MECHAM PONTIAC BUICK 1720 PIONEER AVENUE
JEEP
CHEYENNE, 82001
1
0.010 SE
MECHAM PONTIAC BUICK 1720 PIONEER AVENUE
JEEP
CHEYENNE, 82001
2
0-003686
0.030 NW
SAM MENKIN
408 WEST 18TH
CHEYENNE, 82001
3
ST
0-003251
0.060 S
DINNEEN LINCOLN
MERCURY
400 WEST 16TH STREET
CHEYENNE, 82001
4
3
VRPBF
2139
0.060 S
DINNEEN PROPERTY
400 WEST 16TH STREET
CHEYENNE
5
3
RCRAGR08
WYD036001873
0.060 S
DINNEEN LINCOLN
MERCURY SUBARU
400 WEST 16TH STREET
CHEYENNE, 82001
6
4
VRPBF
2056
0.060 SW
FORMER WORTHAM
MACHINERY CO.
517 W. 17TH STREET
CHEYENNE
8
4
ST
0-001342
0.080 S
MORRIS A. WOLIN TRUST
522 WEST 16TH STREET
CHEYENNE, 82001
9
5
ST
0-004335
0.070 S
EAGLES AERIE # 128
1600 THOMES AVENUE
CHEYENNE, 82001
10
5
LST
4335
0.070 S
EAGLES AERIE # 128
1600 THOMES AVENUE
CHEYENNE, 82001
11
6
LST
5054
0.100 S
GSA MOTOR POOL
501 WEST LINCOLNWAY
CHEYENNE, 82001
12
6
LST
164
0.110 S
FUEL SPECIALISTS
CORPORATION
519 WEST 16TH STREET P.O. BOX CHEYENNE, 82001
445
13
6
ST
0-005054
0.100 S
GSA MOTOR POOL
501 WEST LINCOLNWAY
CHEYENNE, 82001
14
6
ST
0-000164
0.110 S
FUEL SPECIALISTS
CORPORATION
519 WEST 16TH STREET
P. O. BOX 445
CHEYENNE, 82001
15
6
RCRAGR08
WYR000212449
0.110 S
HALLER'S REPAIR
521 W. LINCOLNWAY
CHEYENNE, 82001
16
7
ST
0-005047
0.100 S
GOODYEAR AUTO
SERVICE CENTER #81
401 WEST 16 STREET
CHEYENNE, 82001
17
7
RCRAGR08
WYD981549900
0.100 S
GOODYEAR TIRE &
RUBBER CO
401 W 16TH ST
CHEYENNE, 82001
18
8
ST
0-005094
0.100 NW
LARAMIE COUNTY
DETENTION CENTER
1910 PIONEER
CHEYENNE, 82001
19
9
ST
0-000941
0.100 W
CHECKER-YELLOW CAB
COMPANY
1808 O'NEIL AVENUE
CHEYENNE, 82001
20
10
ST
0-003520
0.100 S
FLACK OUTDOOR
ADVERTISING, INC.
423 WEST 16TH STREET
CHEYENNE, 82001
21
11
ST
0-000860
0.110 N
LARAMIE COUNTY
GOVERNMENT
19TH AND CAREY AVENUE
CHEYENNE
22
11
LST
860
0.110 N
LARAMIE COUNTY
GOVERNMENT
19TH AND CAREY AVENUE
CHEYENNE
23
12
ST
0-004172
0.130 S
SUBURBAN PROPANE
601 WEST LINCOLNWAY
CHEYENNE, 82001
24
12
LST
4172
0.130 S
SUBURBAN PROPANE
601 WEST LINCOLNWAY
CHEYENNE, 82001
25
SITE NAME
ADDRESS
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
SUMMARY 1
REPORT SUMMARY OF LOCATABLE SITES
MAP DATABASE
ID#
NAME
SITE ID#
DISTANCE
FROM SITE
SITE NAME
13
NLRRCRAT
WYD988874673
0.130 E
14
ST
0-001124
15
ST
15
CITY, ZIP CODE
PAGE
#
UNION PACIFIC RAILROAD 201 WEST 17TH STREET
CHEYENNE, 82001
26
0.160 SW
RUTLEDGE RADIATOR AND 621 WEST LINCOLNWAY
WELDING
CHEYENNE, 82001
28
0-001491
0.180 W
AANDI MVMS
723 WEST 19TH STREET
CHEYENNE, 82001
29
LST
1491
0.180 W
AANDI MVMS
723 WEST 19TH STREET
CHEYENNE, 82001
30
16
ST
0-005173
0.180 SW
CHEYENNE NEWSPAPERS, 702 WEST LINCOLNWAY
INC.
CHEYENNE, 82001
31
16
LST
5173
0.180 SW
CHEYENNE NEWSPAPERS, 702 WEST LINCOLNWAY
INC.
CHEYENNE, 82001
32
17
ST
0-005048
0.180 N
PARKING LOT ROCKY
MOUNTAIN FSB
2002 CAREY AVENUE
CHEYENNE, 82001
33
17
LST
5048
0.180 N
PARKING LOT ROCKY
MOUNTAIN FSB
2002 CAREY AVENUE
CHEYENNE, 82001
34
18
ST
0-000858
0.180 W
HEADQUARTERS FIRE
STATION
706 WEST 19TH STREET
CHEYENNE, 82001
35
18
LST
858
0.180 W
HEADQUARTERS FIRE
STATION
706 WEST 19TH STREET
CHEYENNE, 82001
36
ADDRESS
19
ST
0-003588
0.190 NE
CHEYENNE MAIN
1919 CAPITOL AVENUE 3D
CHEYENNE, 82001
37
19
LST
3588
0.190 NE
CHEYENNE MAIN
1919 CAPITOL AVENUE 3D
CHEYENNE, 82001
38
20
ST
0-000488
0.190 N
FIRESTONE STORE
#4855/010456
2001 CAREY AVENUE
CHEYENNE, 82001
39
21
VRPBF
2053
0.190 SW
709 WEST LINCOLNWAY,
CHEYENNE
709 WEST LINCOLNWAY
CHEYENNE
40
22
ST
0-001079
0.200 NE
DOWNTOWN CONOCO
1802 CENTRAL AVENUE
CHEYENNE, 82001
41
23
ST
0-001681
0.210 W
SNYDER SUBSTATION
800 WEST 18TH STREET
CHEYENNE, 82001
42
23
LST
1681
0.210 W
SNYDER SUBSTATION
800 WEST 18TH STREET
CHEYENNE, 82001
43
24
LST
2590
0.220 SE
CHEYENNE STATION
121 WEST 15TH STREET
CHEYENNE, 82001
44
24
ST
0-002590
0.220 SE
CHEYENNE STATION
121 WEST 15TH STREET
CHEYENNE, 82001
45
24
VRPBF
2040
0.220 SE
UPRR RAILROAD FACILITY 121 W 15TH ST.
CHEYENNE
47
24
RCRAC
WYD120371810
0.220 SE
UPRR YARD (VULCAN
CHEM SPILL)
121 WEST 15TH ST
CHEYENNE, 82001
48
25
ST
0-002701
0.220 SE
GREYHOUND LINES, INC.
#8203
1503 CAPITOL AVENUE
CHEYENNE, 82001
50
26
ST
0-004281
0.230 N
EMERSON BUILDING
EMERGENCY POWER
2001 CAPITOL AVENUE
CHEYENNE, 82001
51
27
ST
0-005166
0.240 SW
JERRYS TOPPERS AND
CUSTOM UPHOLSTERY
803 WEST LINCOLNWAY
CHEYENNE, 82001
52
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
SUMMARY 2
REPORT SUMMARY OF LOCATABLE SITES
MAP DATABASE
ID#
NAME
SITE ID#
DISTANCE
FROM SITE
27
LST
5166
28
SWF
28
SITE NAME
ADDRESS
CITY, ZIP CODE
PAGE
#
0.240 SW
JERRYS TOPPERS AND
CUSTOM UPHOLSTERY
803 WEST LINCOLNWAY
CHEYENNE, 82001
53
111
0.240 NW
CHEYENNE LANDFILL
(10.080)
CITY ENGINEERS OFFICE, 2101
O'NEIL,
CHEYENNE, 82001
54
SWF
398
0.240 NW
CHEYENNE TRANSFER
STATION (50.217)
2101 O''NEIL AVENUE
CHEYENNE, 82001
55
29
ST
0-003980
0.250 SE
UNION PACIFIC RAILROAD 105 WEST 15TH STREET
CHEYENNE, 82001
56
29
LST
3980
0.250 SE
UNION PACIFIC RAILROAD 105 WEST 15TH STREET
CHEYENNE, 82001
57
30
ST
0-004015
0.250 W
STEEL CREEK TRAILER
SALES
801 WEST 19TH STREET
CHEYENNE, 82001
58
30
LST
4015
0.250 W
STEEL CREEK TRAILER
SALES
801 WEST 19TH STREET
CHEYENNE, 82001
59
31
ST
0-001492
0.250 W
DAFC/MVMS
801 WEST 20TH STREET
CHEYENNE, 82001
60
32
LST
179
0.260 SW
BIG D #32
820 WEST LINCOLNWAY
CHEYENNE, 82001
61
33
NFRAP
WY0000551762
0.270 SW
CHEYENNE CITY GAS CO
SNYDER AVE & W 18TH ST, SE
CORNER
CHEYENNE, 82001
62
33
CERCLIS
WY0000551762
0.270 SW
CHEYENNE CITY GAS CO
SNYDER AVE & W 18TH ST, SE
CORNER
CHEYENNE, 82001
63
34
LST
5018
0.290 E
ROYAL GLASS
200 EAST 17TH
CHEYENNE, 82001
64
35
LST
1366
0.310 SW
FLEET MAINTENANCE
DEPARTMENT
1500 SNYDER AVENUE
CHEYENNE, 82001
65
36
VRPBF
2090
0.320 E
HARDEE'S RESTAURANT
216 E. LINCOLNWAY
CHEYENNE, 82601
66
37
VRPBF
2132
0.330 E
DELUXE CLEANERS &
TAILORS
1614 HOUSE AVE.
CHEYENNE
67
38
LST
3475
0.330 E
KUM AND GO #956
215 EAST LINCOLNWAY
CHEYENNE
68
39
LST
2017
0.370 E
LINCOLNWAY FAST BREAK 300 EAST LINCOLNWAY
CHEYENNE, 82001
69
40
LST
1308
0.370 W
SNYDER FOOD AND GAS
2100 SNYDER AVENUE
CHEYENNE, 82001
70
41
LST
2232
0.380 SW
E-Z AUTO SALES
1001 WEST 16TH STREET
CHEYENNE, 82001
71
42
LST
4328
0.420 N
BARRETT BUILDING
EMERGENCY POWER
2301 CENTRAL AVENUE
CHEYENNE, 82001
72
43
LST
2282
0.440 W
INTERMOUNTAIN SAFETY 1122 WEST 19TH STREET
CHEYENNE, 82001
73
44
LST
3368
0.450 SW
MESIC'S CONOCO
1131 WEST LINCOLNWAY
CHEYENNE, 82001
74
45
VRPBF
1007
0.460 E
CHEYENNE VILLAGE INN
411 E. 16TH STREET
CHEYENNE
75
46
LST
3978
0.500 W
AMERIGAS
1000 WEST 23RD STREET
CHEYENNE, 82001
76
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
SUMMARY 3
REPORT SUMMARY OF LOCATABLE SITES
MAP DATABASE
ID#
NAME
SITE ID#
DISTANCE
FROM SITE
47
LST
4307
48
LST
49
SITE NAME
ADDRESS
CITY, ZIP CODE
PAGE
#
0.500 E
VACANT GARAGE - 502
EAST LINCOLNWAY
502 EAST LINCOLNWAY
CHEYENNE, 82001
77
276
0.500 N
CHEYENNE REGIONAL
MEDICAL CENTER
300 EAST 23RD STREET
CHEYENNE, 82001
78
VRPBF
2029
0.500 NW
2500 BLOCK OF THOMES
AVE, CHEYENNE
2500 BLOCK OF THOMES
CHEYENNE
79
50
LST
527
0.500 W
AMERIGAS CHEYENNE
1021 WEST 23RD STREET
CHEYENNE, 82001
80
51
RCRAC
WYD988870226
0.790 W
GLACIER PARK PROPERTY WEST OF B.N. RR YARD 1201 W
- CHEYENNE
27TH ST
CHEYENNE, 82001
81
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
SUMMARY 4
STORAGE TANKS (ST)
MAP ID# 1
Distance from Property: 0.01 mi. SE
SITE INFORMATION
SITE ID:
0-000012
SITE NAME:
MECHAM PONTIAC BUICK JEEP
1720 PIONEER AVENUE
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
SAFE SUCTION
2
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
SAFE SUCTION
3
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
OTHER
TANK CAPACITY:
560
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
SAFE SUCTION
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
1
LEAKING STORAGE TANKS (LST)
MAP ID# 1
Distance from Property: 0.01 mi. SE
SITE INFORMATION
SITE ID:
12
SITE NAME:
ADDRESS:
MECHAM PONTIAC BUICK JEEP
1720 PIONEER AVENUE
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
2
STORAGE TANKS (ST)
MAP ID# 2
Distance from Property: 0.03 mi. NW
SITE INFORMATION
SITE ID:
0-003686
SITE NAME:
SAM MENKIN
408 WEST 18TH
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
2
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
3
STORAGE TANKS (ST)
MAP ID# 3
Distance from Property: 0.06 mi. S
SITE INFORMATION
SITE ID:
0-003251
SITE NAME:
DINNEEN LINCOLN MERCURY
400 WEST 16TH STREET
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
01-JAN-70
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
USED OIL
TANK CAPACITY:
500
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
GRAVITY FEED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
4
VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF)
MAP ID# 3
Distance from Property: 0.06 mi. S
SITE INFORMATION
SITE NUMBER: 2139
SITE NAME:
DINNEEN PROPERTY
ADDRESS:
400 WEST 16TH STREET
CHEYENNE, WY
COUNTY:
LARAMIE
STATUS:
OPEN
VOLUNTEER:
SITE TYPE:
W.E. DINNEEN, INC./ DINCO LAND, INC.
VRP
VRP ACCEPTANCE DATE: 10/8/2010
PRELIMINARY REMEDIATION AGREEMENT DATE: 2/22/2011
REMEDY AGREEMENT DATE: NOT REPORTED
LIABILITY ASSURANCE:
NOT REPORTED
VRP PROJECT MANAGER: CINDI MARTINEZ
INSTITUTIONAL CONTROL: NO
TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
5
RESOURCE CONSERVATION & RECOVERY ACT - GENERATOR FACILITIES (RCRAGR08)
MAP ID# 3
Distance from Property: 0.06 mi. S
FACILITY INFORMATION
EPA ID#: WYD036001873
OWNER TYPE: PRIVATE
NAME: DINNEEN LINCOLN MERCURY SUBARU
OWNER NAME: DINNEEN W.J.
ADDRESS: 400 WEST 16TH STREET
OPERATOR TYPE: NOT REPORTED
OPERATOR NAME: NOT REPORTED
CHEYENNE, WY 82001
CONTACT NAME: JOHN DINNEEN
CONTACT ADDRESS: P.O. BOX 27
CHEYENNE, WY 82003
CONTACT PHONE: 3076347733
NON-NOTIFIER: NOT A NON-NOTIFIER
DATE RECEIVED BY AGENCY: 04/04/1986
CERTIFICATION
- NO CERTIFICATION REPORTED -
INDUSTRY CLASSIFICATION (NAICS)
- NO NAICS INFORMATION REPORTED
SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS)
DATE RECEIVED BY AGENCY: 04/04/86
NAME: DINNEEN LINCOLN MERCURY SUBARU
GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR
ACTIVITY INFORMATION
GENERATOR STATUS: SMALL QUANTITY GENERATOR
SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO
TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO
TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO
NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO
CORRECTIVE ACTION WORKLOAD UNIVERSE: NO
IMPORTER: NO
UNDERGROUND INJECTION: NO
MIXED WASTE GENERATOR: NO
UNIVERSAL WASTE DESTINATION FACILITY: NO
RECYCLER: NO
TRANSFER FACILITY: NO
TRANSPORTER: NO
USED OIL FUEL BURNER: NO
ONSITE BURNER EXEMPTION: NO
USED OIL PROCESSOR: NO
FURNACE EXEMPTION: NO
USED OIL FUEL MARKETER TO BURNER: NO
USED OIL REFINER: NO
SPECIFICATION USED OIL MARKETER: NO
USED OIL TRANSFER FACILITY: NO
USED OIL TRANSPORTER: NO
COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION
EVALUATIONS
1993/08/19
CEI COMPLIANCE EVALUATION INSPECTION ON-SITE
1994/01/03
NRR NON-FINANCIAL RECORD REVIEW
1994/05/05
NRR NON-FINANCIAL RECORD REVIEW
1995/04/12
CEI COMPLIANCE EVALUATION INSPECTION ON-SITE
1995/04/27
NRR NON-FINANCIAL RECORD REVIEW
1998/01/26
CEI COMPLIANCE EVALUATION INSPECTION ON-SITE
1998/01/26
FUI FOLLOW-UP INSPECTION
VIOLATIONS
1993/12/28
262.A GENERATORS - GENERAL
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
6
RESOURCE CONSERVATION & RECOVERY ACT - GENERATOR FACILITIES (RCRAGR08)
1993/12/28
279.C USED OIL - GENERATORS
1998/01/26
262.A GENERATORS - GENERAL
1998/01/26
262.B GENERATORS - MANIFEST
1998/01/26
279.C USED OIL - GENERATORS
ENFORCEMENTS
1994/01/12
120 WRITTEN INFORMAL
HAZARDOUS WASTE
UNIVERSAL WASTE
NO HAZARDOUS WASTE INFORMATION REPORTED
- NO UNIVERSAL WASTE REPORTED -
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
7
VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF)
MAP ID# 4
Distance from Property: 0.06 mi. SW
SITE INFORMATION
SITE NUMBER: 2056
SITE NAME:
ADDRESS:
FORMER WORTHAM MACHINERY CO.
517 W. 17TH STREET
CHEYENNE, WY
COUNTY:
LARAMIE
STATUS:
CLOSED
VOLUNTEER:
SITE TYPE:
DINCO LAND, INC.
VRP
VRP ACCEPTANCE DATE: 7/13/2005
PRELIMINARY REMEDIATION AGREEMENT DATE: 7/29/2005
REMEDY AGREEMENT DATE: NA
LIABILITY ASSURANCE:
NA
VRP PROJECT MANAGER: NOT APPLICABLE
INSTITUTIONAL CONTROL: NO
TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
8
STORAGE TANKS (ST)
MAP ID# 4
Distance from Property: 0.08 mi. S
SITE INFORMATION
SITE ID:
0-001342
SITE NAME:
MORRIS A. WOLIN TRUST
522 WEST 16TH STREET
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
24-FEB-71
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
4000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
2
DATE INSTALLED:
24-FEB-71
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
4000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
3
DATE INSTALLED:
24-FEB-71
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
8000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
9
STORAGE TANKS (ST)
MAP ID# 5
Distance from Property: 0.07 mi. S
SITE INFORMATION
SITE ID:
0-004335
SITE NAME:
EAGLES AERIE # 128
1600 THOMES AVENUE
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
10
LEAKING STORAGE TANKS (LST)
MAP ID# 5
Distance from Property: 0.07 mi. S
SITE INFORMATION
SITE ID:
4335
SITE NAME:
ADDRESS:
EAGLES AERIE # 128
1600 THOMES AVENUE
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
11
LEAKING STORAGE TANKS (LST)
MAP ID# 6
Distance from Property: 0.10 mi. S
SITE INFORMATION
SITE ID:
5054
SITE NAME:
GSA MOTOR POOL
ADDRESS:
501 WEST LINCOLNWAY
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
12
LEAKING STORAGE TANKS (LST)
MAP ID# 6
Distance from Property: 0.11 mi. S
SITE INFORMATION
SITE ID:
164
SITE NAME:
FUEL SPECIALISTS CORPORATION
ADDRESS:
519 WEST 16TH STREET P.O. BOX 445
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
UNRESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NO
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
13
STORAGE TANKS (ST)
MAP ID# 6
Distance from Property: 0.10 mi. S
SITE INFORMATION
SITE ID:
0-005054
SITE NAME:
GSA MOTOR POOL
ADDRESS:
501 WEST LINCOLNWAY
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
USED OIL
TANK CAPACITY:
500
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
GRAVITY FEED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
14
STORAGE TANKS (ST)
MAP ID# 6
Distance from Property: 0.11 mi. S
SITE INFORMATION
SITE ID:
0-000164
SITE NAME:
FUEL SPECIALISTS CORPORATION
519 WEST 16TH STREET
ADDRESS:
P. O. BOX 445
CHEYENNE,
WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
21-JUN-64
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
3000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
PRESSURIZED
2
DATE INSTALLED:
21-JUN-64
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
4000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
PRESSURIZED
3
DATE INSTALLED:
01-JAN-40
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
2000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
4
DATE INSTALLED:
01-JAN-40
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
15
RESOURCE CONSERVATION & RECOVERY ACT - GENERATOR FACILITIES (RCRAGR08)
MAP ID# 6
Distance from Property: 0.11 mi. S
FACILITY INFORMATION
EPA ID#: WYR000212449
OWNER TYPE: NOT REPORTED
NAME: HALLER'S REPAIR
OWNER NAME: NOT REPORTED
ADDRESS: 521 W. LINCOLNWAY
OPERATOR TYPE: NOT REPORTED
OPERATOR NAME: NOT REPORTED
CHEYENNE, WY 82001
CONTACT NAME: NOT REPORTED
CONTACT ADDRESS:
,
CONTACT PHONE: NOT REPORTED
NON-NOTIFIER: NOT A NON-NOTIFIER
DATE RECEIVED BY AGENCY: 08/06/2012
CERTIFICATION
- NO CERTIFICATION REPORTED -
INDUSTRY CLASSIFICATION (NAICS)
- NO NAICS INFORMATION REPORTED
SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS)
DATE RECEIVED BY AGENCY: 08/06/12
NAME: HALLER'S REPAIR
GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR
ACTIVITY INFORMATION
GENERATOR STATUS: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR
SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO
TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO
TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO
NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO
CORRECTIVE ACTION WORKLOAD UNIVERSE: NO
IMPORTER: NO
UNDERGROUND INJECTION: NO
MIXED WASTE GENERATOR: NO
UNIVERSAL WASTE DESTINATION FACILITY: NO
RECYCLER: NO
TRANSFER FACILITY: NO
TRANSPORTER: NO
USED OIL FUEL BURNER: NO
ONSITE BURNER EXEMPTION: NO
USED OIL PROCESSOR: NO
FURNACE EXEMPTION: NO
USED OIL FUEL MARKETER TO BURNER: NO
USED OIL REFINER: NO
SPECIFICATION USED OIL MARKETER: NO
USED OIL TRANSFER FACILITY: NO
USED OIL TRANSPORTER: NO
COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION
EVALUATIONS
2012/08/06
CEI COMPLIANCE EVALUATION INSPECTION ON-SITE
VIOLATIONS
2012/08/06
279.C USED OIL - GENERATORS
ENFORCEMENTS - NO ENFORCEMENTS REPORTED HAZARDOUS WASTE
UNIVERSAL WASTE
NO HAZARDOUS WASTE INFORMATION REPORTED
- NO UNIVERSAL WASTE REPORTED -
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
16
STORAGE TANKS (ST)
MAP ID# 7
Distance from Property: 0.10 mi. S
SITE INFORMATION
SITE ID:
0-005047
SITE NAME:
GOODYEAR AUTO SERVICE CENTER #81
401 WEST 16 STREET
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
01-JUN-86
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
USED OIL
TANK CAPACITY:
550
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
GRAVITY FEED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
17
RESOURCE CONSERVATION & RECOVERY ACT - GENERATOR FACILITIES (RCRAGR08)
MAP ID# 7
Distance from Property: 0.10 mi. S
FACILITY INFORMATION
EPA ID#: WYD981549900
OWNER TYPE: PRIVATE
NAME: GOODYEAR TIRE & RUBBER CO
OWNER NAME: GOODYEAR TIRE & RUBBER CO
ADDRESS: 401 W 16TH ST
OPERATOR TYPE: NOT REPORTED
OPERATOR NAME: NOT REPORTED
CHEYENNE, WY 82001
CONTACT NAME: GORDON KARDELL
CONTACT ADDRESS: PO BOX 7177 PARKHILL STATION
DENVER, CO 80207
CONTACT PHONE: 3033946626
NON-NOTIFIER: NOT A NON-NOTIFIER
DATE RECEIVED BY AGENCY: 07/14/1987
CERTIFICATION
- NO CERTIFICATION REPORTED -
INDUSTRY CLASSIFICATION (NAICS)
- NO NAICS INFORMATION REPORTED
SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS)
DATE RECEIVED BY AGENCY: 07/14/87
NAME: GOODYEAR TIRE & RUBBER CO
GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR
ACTIVITY INFORMATION
GENERATOR STATUS: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR
SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO
TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO
TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO
NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO
CORRECTIVE ACTION WORKLOAD UNIVERSE: NO
IMPORTER: NO
UNDERGROUND INJECTION: NO
MIXED WASTE GENERATOR: NO
UNIVERSAL WASTE DESTINATION FACILITY: NO
RECYCLER: NO
TRANSFER FACILITY: NO
TRANSPORTER: NO
USED OIL FUEL BURNER: NO
ONSITE BURNER EXEMPTION: NO
USED OIL PROCESSOR: NO
FURNACE EXEMPTION: NO
USED OIL FUEL MARKETER TO BURNER: NO
USED OIL REFINER: NO
SPECIFICATION USED OIL MARKETER: NO
USED OIL TRANSFER FACILITY: NO
USED OIL TRANSPORTER: NO
COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION
EVALUATIONS
2000/06/05
CEI COMPLIANCE EVALUATION INSPECTION ON-SITE
2000/06/05
NRR NON-FINANCIAL RECORD REVIEW
VIOLATIONS
2000/06/05
279.C USED OIL - GENERATORS
ENFORCEMENTS - NO ENFORCEMENTS REPORTED HAZARDOUS WASTE
D001
IGNITABLE WASTE
UNIVERSAL WASTE
- NO UNIVERSAL WASTE REPORTED -
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
18
STORAGE TANKS (ST)
MAP ID# 8
Distance from Property: 0.10 mi. NW
SITE INFORMATION
SITE ID:
0-005094
SITE NAME:
LARAMIE COUNTY DETENTION CENTER
1910 PIONEER
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
01-AUG-89
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
8000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
U.S. SUCTION
2
DATE INSTALLED:
01-NOV-01
TANK STATUS:
CURRENTLY IN USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
2500
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
SAFE SUCTION
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
19
STORAGE TANKS (ST)
MAP ID# 9
Distance from Property: 0.10 mi. W
SITE INFORMATION
SITE ID:
0-000941
SITE NAME:
CHECKER-YELLOW CAB COMPANY
1808 O'NEIL AVENUE
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
550
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
2
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
550
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
3
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
NOT LISTED
TANK CAPACITY:
550
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
20
STORAGE TANKS (ST)
MAP ID# 10
Distance from Property: 0.10 mi. S
SITE INFORMATION
SITE ID:
0-003520
SITE NAME:
FLACK OUTDOOR ADVERTISING, INC.
423 WEST 16TH STREET
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
24-JAN-59
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
2
DATE INSTALLED:
24-JAN-59
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
3
DATE INSTALLED:
24-JAN-59
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
21
STORAGE TANKS (ST)
MAP ID# 11
Distance from Property: 0.11 mi. N
SITE INFORMATION
SITE ID:
0-000860
SITE NAME:
LARAMIE COUNTY GOVERNMENT
19TH AND CAREY AVENUE
ADDRESS:
CHEYENNE, WY
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
11-APR-85
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
560
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
2
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
22
LEAKING STORAGE TANKS (LST)
MAP ID# 11
Distance from Property: 0.11 mi. N
SITE INFORMATION
SITE ID:
860
SITE NAME:
ADDRESS:
LARAMIE COUNTY GOVERNMENT
19TH AND CAREY AVENUE
CHEYENNE, WY
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
23
STORAGE TANKS (ST)
MAP ID# 12
Distance from Property: 0.13 mi. S
SITE INFORMATION
SITE ID:
0-004172
SITE NAME:
SUBURBAN PROPANE
601 WEST LINCOLNWAY
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
01-JAN-70
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
10000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
SAFE SUCTION
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
24
LEAKING STORAGE TANKS (LST)
MAP ID# 12
Distance from Property: 0.13 mi. S
SITE INFORMATION
SITE ID:
4172
SITE NAME:
ADDRESS:
SUBURBAN PROPANE
601 WEST LINCOLNWAY
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
25
NO LONGER REGULATED RCRA NON-CORRACTS TSD FACILITIES (NLRRCRAT)
MAP ID# 13
Distance from Property: 0.13 mi. E
FACILITY INFORMATION
EPA ID#: WYD988874673
OWNER TYPE: PRIVATE
NAME: UNION PACIFIC RAILROAD
OWNER NAME: UNION PACIFIC RAILROAD
ADDRESS: 201 WEST 17TH STREET
OPERATOR TYPE: PRIVATE
OPERATOR NAME: UNION PACIFIC RAILROAD
CHEYENNE, WY 82001
CONTACT NAME: GARY L HONEYMAN
CONTACT ADDRESS: 15TH & CAPITOL STREET
CHEYENNE, WY 82001
CONTACT PHONE: 4022331007
NON-NOTIFIER: NOT A NON-NOTIFIER
DATE RECEIVED BY AGENCY: 05/18/2010
CERTIFICATION
CERTIFICATION NAME:
CERTIFICATION TITLE:
CERTIFICATION SIGNED DATE:
GARY L HONEYMAN
MGR ENV. SITE REMEDIATION
20100517
EDGAR R MCNUTT
MGR.COMPL.MEAS.
19940327
WILLIAM L HAMMOND
MANAGER
19960225
INDUSTRY CLASSIFICATION (NAICS)
482111 - LINE-HAUL RAILROADS
SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS)
DATE RECEIVED BY AGENCY: 02/25/96
NAME: UNION PACIFIC RAILROAD
GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR
DATE RECEIVED BY AGENCY: 03/27/94
NAME: UPRR CHEYENNE
GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR
DATE RECEIVED BY AGENCY: 05/18/10
NAME: UPRR CHEYENNE RAILROAD FACILITY
GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR
DATE RECEIVED BY AGENCY: 07/09/93
NAME: UNION PACIFIC RAILROAD
GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
26
NO LONGER REGULATED RCRA NON-CORRACTS TSD FACILITIES (NLRRCRAT)
ACTIVITY INFORMATION
GENERATOR STATUS: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR
SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO
TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO
TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO
NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO
CORRECTIVE ACTION WORKLOAD UNIVERSE: NO
IMPORTER: NO
UNDERGROUND INJECTION: NO
MIXED WASTE GENERATOR: NO
UNIVERSAL WASTE DESTINATION FACILITY: NO
RECYCLER: NO
TRANSFER FACILITY: NO
TRANSPORTER: NO
USED OIL FUEL BURNER: NO
ONSITE BURNER EXEMPTION: NO
USED OIL PROCESSOR: NO
FURNACE EXEMPTION: NO
USED OIL FUEL MARKETER TO BURNER: NO
USED OIL REFINER: NO
SPECIFICATION USED OIL MARKETER: NO
USED OIL TRANSFER FACILITY: NO
USED OIL TRANSPORTER: NO
COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION
EVALUATIONS
2012/08/30
CEI COMPLIANCE EVALUATION INSPECTION ON-SITE
VIOLATIONS
2012/08/30
279.C USED OIL - GENERATORS
ENFORCEMENTS - NO ENFORCEMENTS REPORTED HAZARDOUS WASTE
U210
ETHENE, TETRACHLORO-
D002
CORROSIVE WASTE
D006
CADMIUM
D009
MERCURY
D010
SELENIUM
UNIVERSAL WASTE
- NO UNIVERSAL WASTE REPORTED -
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
27
STORAGE TANKS (ST)
MAP ID# 14
Distance from Property: 0.16 mi. SW
SITE INFORMATION
SITE ID:
0-001124
SITE NAME:
RUTLEDGE RADIATOR AND WELDING
621 WEST LINCOLNWAY
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
16-APR-36
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
750
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
2
DATE INSTALLED:
16-APR-36
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
750
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
3
DATE INSTALLED:
16-APR-36
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1500
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
4
DATE INSTALLED:
16-APR-36
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1500
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
28
STORAGE TANKS (ST)
MAP ID# 15
Distance from Property: 0.18 mi. W
SITE INFORMATION
SITE ID:
0-001491
SITE NAME:
AANDI MVMS
723 WEST 19TH STREET
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
01-JAN-74
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
10000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
SAFE SUCTION
2
DATE INSTALLED:
01-JAN-74
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
10000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
SAFE SUCTION
3
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
10000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
SAFE SUCTION
4
DATE INSTALLED:
01-MAY-91
TANK STATUS:
CURRENTLY IN USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
20000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
SAFE SUCTION
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
29
LEAKING STORAGE TANKS (LST)
MAP ID# 15
Distance from Property: 0.18 mi. W
SITE INFORMATION
SITE ID:
1491
SITE NAME:
ADDRESS:
AANDI MVMS
723 WEST 19TH STREET
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
1
CONFIRMED RELEASE DATE: 06/23/91
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
30
STORAGE TANKS (ST)
MAP ID# 16
Distance from Property: 0.18 mi. SW
SITE INFORMATION
SITE ID:
0-005173
SITE NAME:
CHEYENNE NEWSPAPERS, INC.
702 WEST LINCOLNWAY
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
NOT LISTED
TANK CAPACITY:
NOT REPORTED
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
31
LEAKING STORAGE TANKS (LST)
MAP ID# 16
Distance from Property: 0.18 mi. SW
SITE INFORMATION
SITE ID:
5173
SITE NAME:
ADDRESS:
CHEYENNE NEWSPAPERS, INC.
702 WEST LINCOLNWAY
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
32
STORAGE TANKS (ST)
MAP ID# 17
Distance from Property: 0.18 mi. N
SITE INFORMATION
SITE ID:
0-005048
SITE NAME:
PARKING LOT ROCKY MOUNTAIN FSB
2002 CAREY AVENUE
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
01-JAN-28
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
33
LEAKING STORAGE TANKS (LST)
MAP ID# 17
Distance from Property: 0.18 mi. N
SITE INFORMATION
SITE ID:
5048
SITE NAME:
ADDRESS:
PARKING LOT ROCKY MOUNTAIN FSB
2002 CAREY AVENUE
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
34
STORAGE TANKS (ST)
MAP ID# 18
Distance from Property: 0.18 mi. W
SITE INFORMATION
SITE ID:
0-000858
SITE NAME:
HEADQUARTERS FIRE STATION
706 WEST 19TH STREET
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
12-APR-79
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
2000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
2
DATE INSTALLED:
12-APR-79
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
4000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
3
DATE INSTALLED:
12-APR-79
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
6000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
4
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
USED OIL
TANK CAPACITY:
500
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
5
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
OTHER
TANK CAPACITY:
560
SPECIFICATION DESCRIPTION: FIBERGLASS REINFORCED PLASTIC - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
35
LEAKING STORAGE TANKS (LST)
MAP ID# 18
Distance from Property: 0.18 mi. W
SITE INFORMATION
SITE ID:
858
SITE NAME:
ADDRESS:
HEADQUARTERS FIRE STATION
706 WEST 19TH STREET
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
36
STORAGE TANKS (ST)
MAP ID# 19
Distance from Property: 0.19 mi. NE
SITE INFORMATION
SITE ID:
0-003588
SITE NAME:
CHEYENNE MAIN
1919 CAPITOL AVENUE 3D
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
30-JUN-69
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
3000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
2
DATE INSTALLED:
01-JAN-50
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
NOT LISTED
TANK CAPACITY:
750
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
37
LEAKING STORAGE TANKS (LST)
MAP ID# 19
Distance from Property: 0.19 mi. NE
SITE INFORMATION
SITE ID:
3588
SITE NAME:
ADDRESS:
CHEYENNE MAIN
1919 CAPITOL AVENUE 3D
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
38
STORAGE TANKS (ST)
MAP ID# 20
Distance from Property: 0.19 mi. N
SITE INFORMATION
SITE ID:
0-000488
SITE NAME:
FIRESTONE STORE #4855/010456
2001 CAREY AVENUE
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
01-JAN-79
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
USED OIL
TANK CAPACITY:
560
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
39
VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF)
MAP ID# 21
Distance from Property: 0.19 mi. SW
SITE INFORMATION
SITE NUMBER: 2053
SITE NAME:
ADDRESS:
709 WEST LINCOLNWAY, CHEYENNE
709 WEST LINCOLNWAY
CHEYENNE, WY
COUNTY:
LARAMIE
STATUS:
OPEN
VOLUNTEER:
SITE TYPE:
MECHANICAL SYSTEMS
VRP
VRP ACCEPTANCE DATE: 6/16/2005
PRELIMINARY REMEDIATION AGREEMENT DATE: NA
REMEDY AGREEMENT DATE: 6/18/2007
LIABILITY ASSURANCE:
6/18/2007
VRP PROJECT MANAGER: CINDI MARTINEZ
INSTITUTIONAL CONTROL: NO
TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
40
STORAGE TANKS (ST)
MAP ID# 22
Distance from Property: 0.20 mi. NE
SITE INFORMATION
SITE ID:
0-001079
SITE NAME:
DOWNTOWN CONOCO
1802 CENTRAL AVENUE
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
01-JAN-85
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
2000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
SAFE SUCTION
2
DATE INSTALLED:
01-JAN-85
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
2000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
SAFE SUCTION
3
DATE INSTALLED:
01-JAN-77
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
6000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
SAFE SUCTION
4
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
USED OIL
TANK CAPACITY:
500
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
SAFE SUCTION
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
41
STORAGE TANKS (ST)
MAP ID# 23
Distance from Property: 0.21 mi. W
SITE INFORMATION
SITE ID:
0-001681
SITE NAME:
SNYDER SUBSTATION
800 WEST 18TH STREET
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
26-JUN-65
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
20000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
SAFE SUCTION
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
42
LEAKING STORAGE TANKS (LST)
MAP ID# 23
Distance from Property: 0.21 mi. W
SITE INFORMATION
SITE ID:
1681
SITE NAME:
ADDRESS:
SNYDER SUBSTATION
800 WEST 18TH STREET
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
43
LEAKING STORAGE TANKS (LST)
MAP ID# 24
Distance from Property: 0.22 mi. SE
SITE INFORMATION
SITE ID:
2590
SITE NAME:
CHEYENNE STATION
ADDRESS:
121 WEST 15TH STREET
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
44
STORAGE TANKS (ST)
MAP ID# 24
Distance from Property: 0.22 mi. SE
SITE INFORMATION
SITE ID:
0-002590
SITE NAME:
CHEYENNE STATION
ADDRESS:
121 WEST 15TH STREET
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
USED OIL
TANK CAPACITY:
20000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
2
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
500
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
3
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
500
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
4
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
20000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
5
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
USED OIL
TANK CAPACITY:
500
SPECIFICATION DESCRIPTION: FIBERGLASS REINFORCED PLASTIC - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
45
STORAGE TANKS (ST)
TANK ID:
6
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
USED OIL
TANK CAPACITY:
500
SPECIFICATION DESCRIPTION: FIBERGLASS REINFORCED PLASTIC - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
46
VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF)
MAP ID# 24
Distance from Property: 0.22 mi. SE
SITE INFORMATION
SITE NUMBER: 2040
SITE NAME:
ADDRESS:
UPRR RAILROAD FACILITY
121 W 15TH ST.
CHEYENNE, WY
COUNTY:
LARAMIE
STATUS:
OPEN
VOLUNTEER:
SITE TYPE:
UNION PACIFIC RAILROAD
VRP
VRP ACCEPTANCE DATE: 1/7/2004
PRELIMINARY REMEDIATION AGREEMENT DATE: 6/1/2004
REMEDY AGREEMENT DATE: NOT REPORTED
LIABILITY ASSURANCE:
NOT REPORTED
VRP PROJECT MANAGER: CINDI MARTINEZ
INSTITUTIONAL CONTROL: NO
TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
47
RESOURCE CONSERVATION & RECOVERY ACT - CORRECTIVE ACTION FACILITIES (RCRAC)
MAP ID# 24
Distance from Property: 0.22 mi. SE
FACILITY INFORMATION
EPA ID#: WYD120371810
OWNER TYPE: NOT REPORTED
NAME: UPRR YARD (VULCAN CHEM SPILL)
OWNER NAME: NOT REPORTED
ADDRESS: 121 WEST 15TH ST
OPERATOR TYPE: PRIVATE
OPERATOR NAME: UPRR VULCAN CHEMICAL SPILL
CHEYENNE, WY 82001
CONTACT NAME: TOM PARROTT
CONTACT ADDRESS: PO BOX 7689
BIRMINGHAM, AL 35253
CONTACT PHONE: 2058773851
NON-NOTIFIER: NOT A NON-NOTIFIER
DATE RECEIVED BY AGENCY: 07/14/2006
INDUSTRY CLASSIFICATION (NAICS)
211112 - NATURAL GAS LIQUID EXTRACTION
482111 - LINE-HAUL RAILROADS
48821 - SUPPORT ACTIVITIES FOR RAIL TRANSPORTATION
SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS)
DATE RECEIVED BY AGENCY: 02/16/00
NAME: UNION PACIFIC RAILROAD YARD
GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR
DATE RECEIVED BY AGENCY: 02/28/92
NAME: UNION PACIFIC RAILROAD YARD
GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR
DATE RECEIVED BY AGENCY: 03/15/90
NAME: UNION PACIFIC RAILROAD YARD
GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR
DATE RECEIVED BY AGENCY: 03/27/96
NAME: UNION PACIFIC RAILROAD YARD
GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR
DATE RECEIVED BY AGENCY: 07/14/06
NAME: UPRR YARD (VULCAN CHEM SPILL)
GENERATOR CLASSIFICATION: NOT A GENERATOR
DATE RECEIVED BY AGENCY: 08/04/89
NAME: UPRR YARD (VULCAN CHEM SPILL)
GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
48
RESOURCE CONSERVATION & RECOVERY ACT - CORRECTIVE ACTION FACILITIES (RCRAC)
ACTIVITY INFORMATION
GENERATOR STATUS: NOT A GENERATOR
SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO
TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO
TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO
NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO
CORRECTIVE ACTION WORKLOAD UNIVERSE: YES
IMPORTER: NO
UNDERGROUND INJECTION: NO
MIXED WASTE GENERATOR: NO
UNIVERSAL WASTE DESTINATION FACILITY: NO
RECYCLER: NO
TRANSFER FACILITY: NO
TRANSPORTER: NO
USED OIL FUEL BURNER: NO
ONSITE BURNER EXEMPTION: NO
USED OIL PROCESSOR: NO
FURNACE EXEMPTION: NO
USED OIL FUEL MARKETER TO BURNER: NO
USED OIL REFINER: NO
SPECIFICATION USED OIL MARKETER: NO
USED OIL TRANSFER FACILITY: NO
USED OIL TRANSPORTER: NO
COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION
EVALUATIONS
2002/01/17
CEI COMPLIANCE EVALUATION INSPECTION ON-SITE
2006/02/13
OAM OPERATION AND MAINTENANCE INSPECTION
VIOLATIONS
- NO VIOLATIONS REPORTED -
ENFORCEMENTS - NO ENFORCEMENTS REPORTED HAZARDOUS WASTE
F003
THE FOLLOWING SPENT NON-HALOGENATED SOLVENTS: XYLENE, ACETONE, ETHYL ACETATE, ETHYL BENZENE,
ETHYL ETHER, METHYL ISOBUTYL KETONE, N-BUTYL ALCOHOL, CYCLOHEXANONE, AND METHANOL; ALL SPENT
SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONLY THE ABOVE SPENT NONHALOGENATED SOLVENTS;
AND ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONE OR MORE OF THE ABOVE
NONHALOGENATED SOLVENTS, AND A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF
THOSE SOLVENTS LISTED IN F001, F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE
SPENT SOLVENTS AND SPENT SOLVENT MIXTURES.
U210
ETHENE, TETRACHLORO-
UNIVERSAL WASTE
- NO UNIVERSAL WASTE REPORTED -
CORRECTIVE ACTION AREA
SPILL SITE ON UPRR YARD
YES
YES
NO
-----
CORRECTIVE ACTION EVENT
CA110
19990922
INVESTIGATION WORKPLAN RECEIVED
CA150
19991105
INVESTIGATION WORKPLAN APPROVED
CA190
20000830
INVESTIGATION REPORT RECEIVED
CA260
20000830
CMS WORKPLAN RECEIVED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
49
STORAGE TANKS (ST)
MAP ID# 25
Distance from Property: 0.22 mi. SE
SITE INFORMATION
SITE ID:
0-002701
SITE NAME:
GREYHOUND LINES, INC. #8203
1503 CAPITOL AVENUE
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
01-JAN-84
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
10000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
PRESSURIZED
2
DATE INSTALLED:
01-JAN-84
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
10000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
PRESSURIZED
3
DATE INSTALLED:
16-JUN-71
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
12000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
50
STORAGE TANKS (ST)
MAP ID# 26
Distance from Property: 0.23 mi. N
SITE INFORMATION
SITE ID:
0-004281
SITE NAME:
EMERSON BUILDING EMERGENCY POWER
2001 CAPITOL AVENUE
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
01-FEB-82
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
2
DATE INSTALLED:
13-OCT-00
TANK STATUS:
CURRENTLY IN USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
SAFE SUCTION
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
51
STORAGE TANKS (ST)
MAP ID# 27
Distance from Property: 0.24 mi. SW
SITE INFORMATION
SITE ID:
0-005166
SITE NAME:
JERRYS TOPPERS AND CUSTOM UPHOLSTERY
803 WEST LINCOLNWAY
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
NOT LISTED
TANK CAPACITY:
NOT REPORTED
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
52
LEAKING STORAGE TANKS (LST)
MAP ID# 27
Distance from Property: 0.24 mi. SW
SITE INFORMATION
SITE ID:
5166
SITE NAME:
ADDRESS:
JERRYS TOPPERS AND CUSTOM UPHOLSTERY
803 WEST LINCOLNWAY
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
UNRESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: Yes
PRIORITY RANKING: 435
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
53
PERMITTED SOLID WASTE FACILITIES (SWF)
MAP ID# 28
Distance from Property: 0.24 mi. NW
SITE INFORMATION
SITE ID:
111
SITE NAME:
ADDRESS:
CHEYENNE LANDFILL (10.080)
CITY ENGINEERS OFFICE, 2101 O'NEIL, ROOM 202
CHEYENNE, WY 82001
OWNER:
CHEYENNE (CITY OF)
SITE DETAILS
FACILITY STATUS:
ACTIVE
FACILITY TYPE:
TYPE I MUNICIPAL
USED OIL ACCEPTED: F
WASTE TYPE:
CONSTRUCTION/DEMOLITION
WASTE TYPE:
MUNICIPAL SW
WASTE TYPE:
PETROLEUM CONTAMINATED SOILS
WASTE TYPE:
SCRAP TIRES
WASTE TYPE:
DEAD ANIMALS
WASTE TYPE:
USED OIL
WASTE TYPE:
SUMP WASTE (NON-HAZARDOUS)
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
54
PERMITTED SOLID WASTE FACILITIES (SWF)
MAP ID# 28
Distance from Property: 0.24 mi. NW
SITE INFORMATION
SITE ID:
398
SITE NAME:
ADDRESS:
CHEYENNE TRANSFER STATION (50.217)
2101 O''NEIL AVENUE
CHEYENNE, WY 82001
OWNER:
CHEYENNE (CITY OF)
SITE DETAILS
FACILITY STATUS:
ACTIVE
FACILITY TYPE:
SW TSD
USED OIL ACCEPTED: F
WASTE TYPE:
HOUSEHOLD HAZARDOUS WASTE
WASTE TYPE:
USED OIL
WASTE TYPE:
CESQG
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
55
STORAGE TANKS (ST)
MAP ID# 29
Distance from Property: 0.25 mi. SE
SITE INFORMATION
SITE ID:
0-003980
SITE NAME:
UNION PACIFIC RAILROAD
105 WEST 15TH STREET
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
500
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
2
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
10000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
NOT LISTED
3
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
500
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
NOT LISTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
56
LEAKING STORAGE TANKS (LST)
MAP ID# 29
Distance from Property: 0.25 mi. SE
SITE INFORMATION
SITE ID:
3980
SITE NAME:
ADDRESS:
UNION PACIFIC RAILROAD
105 WEST 15TH STREET
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
57
STORAGE TANKS (ST)
MAP ID# 30
Distance from Property: 0.25 mi. W
SITE INFORMATION
SITE ID:
0-004015
SITE NAME:
STEEL CREEK TRAILER SALES
801 WEST 19TH STREET
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
KEROSENE
TANK CAPACITY:
1000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
SAFE SUCTION
2
DATE INSTALLED:
NOT REPORTED
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
2000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
SAFE SUCTION
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
58
LEAKING STORAGE TANKS (LST)
MAP ID# 30
Distance from Property: 0.25 mi. W
SITE INFORMATION
SITE ID:
4015
SITE NAME:
ADDRESS:
STEEL CREEK TRAILER SALES
801 WEST 19TH STREET
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
59
STORAGE TANKS (ST)
MAP ID# 31
Distance from Property: 0.25 mi. W
SITE INFORMATION
SITE ID:
0-001492
SITE NAME:
DAFC/MVMS
801 WEST 20TH STREET
ADDRESS:
CHEYENNE, WY 82001
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
01-JAN-74
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
10000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
TANK ID:
SAFE SUCTION
2
DATE INSTALLED:
01-JAN-74
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
GASOLINE
TANK CAPACITY:
10000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
SAFE SUCTION
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
60
LEAKING STORAGE TANKS (LST)
MAP ID# 32
Distance from Property: 0.26 mi. SW
SITE INFORMATION
SITE ID:
179
SITE NAME:
ADDRESS:
BIG D #32
820 WEST LINCOLNWAY
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
9
CONFIRMED RELEASE DATE: 03/16/98
SITE TYPE:
UNRESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: Yes
PRIORITY RANKING: 843
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
61
NO FURTHER REMEDIAL ACTION PLANNED SITES (NFRAP)
MAP ID# 33
Distance from Property: 0.27 mi. SW
FACILITY INFORMATION
EPA ID#: WY0000551762
SITE ID#: 0801457
NAME: CHEYENNE CITY GAS CO
ADDRESS: SNYDER AVE & W 18TH ST, SE CORNER
CHEYENNE, WY 82001
COUNTY: LARAMIE
ACTION
START DATE
COMPLETION DATE
RESPONSIBILITY
DS - DISCOVERY
NOT REPORTED
12/15/1993
EPA FUND
PA - PRELIMINARY ASSESSMENT
NOT REPORTED
11/14/1994
EPA FUND
SI - SITE INSPECTION
NOT REPORTED
9/25/1997 00:00:00
EPA FUND
VS - ARCHIVE SITE
NOT REPORTED
11/20/2001
EPA IN-HOUSE
ACTION DESCRIPTIONS
DS - (DISCOVERY) - THE PROCESS BY WHICH A POTENTIAL HAZARDOUS WASTE SITE IS BROUGHT TO THE ATTENTION OF
THE EPA. THE PROCESS CAN OCCUR THROUGH THE USE OF SEVERAL MECHANISMS SUCH AS A PHONE CALL OR
REFERRAL BY ANOTHER GOVERNMENT AGENCY.
PA - (PRELIMINARY ASSESSMENT) - COLLECTION OF DIVERSE EXISTING INFORMATION ABOUT THE SOURCE AND NATURE
OF THE SITE HAZARD. IT IS EPA POLICY TO COMPLETE THE PRELIMINARY ASSESSMENT WITHIN ONE YEAR OF SITE
DISCOVERY.
SI - (SITE INSPECTION) - THE PROCESS OF COLLECTING SITE DATA AND SAMPLES TO CHARACTERIZE THE SEVERITY OF
THE HAZARD FOR THE HAZARD RANKING SCORE AND/OR ENFORCEMENT SUPPORT.
VS - (ARCHIVE SITE) - THE DECISION IS MADE THAT NO FURTHER ACTIVITY IS PLANNED AT THE SITE.
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
62
COMPREHENSIVE ENVIRONMENTAL RESPONSE, COMPENSATION & LIABILITY INFORMATION SYSTEM
(CERCLIS)
MAP ID# 33
Distance from Property: 0.27 mi. SW
FACILITY INFORMATION
EPA ID#: WY0000551762
SITE ID#: 0801457
NAME: CHEYENNE CITY GAS CO
ADDRESS: SNYDER AVE & W 18TH ST, SE CORNER
CHEYENNE, WY 82001
COUNTY: LARAMIE
NATIONAL PRIORITY LISTING: N - NOT ON THE NPL
FEDERAL FACILITY CLASSIFICATION: N - NOT A FEDERAL FACILITY
NON-NPL STATUS: NF - NFRAP
PHYSICAL CLASSIFICATION OF SITE / INCIDENT: ABANDONED
SITE DESCRIPTION - NO SITE DESCRIPTION INFORMATION AVAILABLE SITE HISTORY - NO SITE HISTORY INFORMATION AVAILABLE ACTIONS
TYPE:
DS - DISCOVERY
START DATE: NR
COMPLETION DATE: 12/15/1993
ACTION TYPE DEFINITION:
THE PROCESS BY WHICH A POTENTIAL HAZARDOUS WASTE SITE IS BROUGHT TO THE ATTENTION OF THE EPA. THE
PROCESS CAN OCCUR THROUGH THE USE OF SEVERAL MECHANISMS SUCH AS A PHONE CALL OR REFERRAL BY ANOTHER
GOVERNMENT AGENCY.
TYPE:
PA - PRELIMINARY ASSESSMENT
START DATE: NR
COMPLETION DATE: 11/14/1994
ACTION TYPE DEFINITION:
COLLECTION OF DIVERSE EXISTING INFORMATION ABOUT THE SOURCE AND NATURE OF THE SITE HAZARD. IT IS EPA
POLICY TO COMPLETE THE PRELIMINARY ASSESSMENT WITHIN ONE YEAR OF SITE DISCOVERY.
TYPE:
SI - SITE INSPECTION
START DATE: NR
COMPLETION DATE: 09/25/1997
ACTION TYPE DEFINITION:
THE PROCESS OF COLLECTING SITE DATA AND SAMPLES TO CHARACTERIZE THE SEVERITY OF THE HAZARD FOR THE
HAZARD RANKING SCORE AND/OR ENFORCEMENT SUPPORT.
TYPE:
VS - ARCHIVE SITE
START DATE: NR
COMPLETION DATE: 11/20/2001
ACTION TYPE DEFINITION:
THE DECISION IS MADE THAT NO FURTHER ACTIVITY IS PLANNED AT THE SITE.
CONTAMINANTS
- NO CONTAMINATION INFORMATION AVAILABLE LISTING OF PUBLISHED INSTITUTIONAL CONTROL SITE REPORT - NOT AN INSTITUTIONAL CONTROL SITE -
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
63
LEAKING STORAGE TANKS (LST)
MAP ID# 34
Distance from Property: 0.29 mi. E
SITE INFORMATION
SITE ID:
5018
SITE NAME:
ADDRESS:
ROYAL GLASS
200 EAST 17TH
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
64
LEAKING STORAGE TANKS (LST)
MAP ID# 35
Distance from Property: 0.31 mi. SW
SITE INFORMATION
SITE ID:
1366
SITE NAME:
ADDRESS:
FLEET MAINTENANCE DEPARTMENT
1500 SNYDER AVENUE
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
3
CONFIRMED RELEASE DATE: 05/17/91
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NO
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
65
VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF)
MAP ID# 36
Distance from Property: 0.32 mi. E
SITE INFORMATION
SITE NUMBER: 2090
SITE NAME:
ADDRESS:
HARDEE'S RESTAURANT
216 E. LINCOLNWAY
CHEYENNE, WY 82601
COUNTY:
LARAMIE
STATUS:
CLOSED
VOLUNTEER:
SITE TYPE:
BIG SKY LAND COMPANY LLC
VRP
VRP ACCEPTANCE DATE: 10/23/2006
PRELIMINARY REMEDIATION AGREEMENT DATE: 7/5/2007
REMEDY AGREEMENT DATE: NA
LIABILITY ASSURANCE:
NA
VRP PROJECT MANAGER: NOT APPLICABLE
INSTITUTIONAL CONTROL: NO
TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
66
VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF)
MAP ID# 37
Distance from Property: 0.33 mi. E
SITE INFORMATION
SITE NUMBER: 2132
SITE NAME:
ADDRESS:
DELUXE CLEANERS & TAILORS
1614 HOUSE AVE.
CHEYENNE, WY
COUNTY:
LARAMIE
STATUS:
OPEN
VOLUNTEER:
SITE TYPE:
BASH, INC.
VRP
VRP ACCEPTANCE DATE: 9/25/2009
PRELIMINARY REMEDIATION AGREEMENT DATE: 11/29/2010
REMEDY AGREEMENT DATE: NOT REPORTED
LIABILITY ASSURANCE:
NOT REPORTED
VRP PROJECT MANAGER: NOT APPLICABLE
INSTITUTIONAL CONTROL: NO
TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
67
LEAKING STORAGE TANKS (LST)
MAP ID# 38
Distance from Property: 0.33 mi. E
SITE INFORMATION
SITE ID:
3475
SITE NAME:
KUM AND GO #956
ADDRESS:
215 EAST LINCOLNWAY
CHEYENNE, WY
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
UNRESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
68
LEAKING STORAGE TANKS (LST)
MAP ID# 39
Distance from Property: 0.37 mi. E
SITE INFORMATION
SITE ID:
2017
SITE NAME:
ADDRESS:
LINCOLNWAY FAST BREAK
300 EAST LINCOLNWAY
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
2
CONFIRMED RELEASE DATE: 04/04/97
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
69
LEAKING STORAGE TANKS (LST)
MAP ID# 40
Distance from Property: 0.37 mi. W
SITE INFORMATION
SITE ID:
1308
SITE NAME:
ADDRESS:
SNYDER FOOD AND GAS
2100 SNYDER AVENUE
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
2
CONFIRMED RELEASE DATE: 02/01/99
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
70
LEAKING STORAGE TANKS (LST)
MAP ID# 41
Distance from Property: 0.38 mi. SW
SITE INFORMATION
SITE ID:
2232
SITE NAME:
ADDRESS:
E-Z AUTO SALES
1001 WEST 16TH STREET
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
71
LEAKING STORAGE TANKS (LST)
MAP ID# 42
Distance from Property: 0.42 mi. N
SITE INFORMATION
SITE ID:
4328
SITE NAME:
ADDRESS:
BARRETT BUILDING EMERGENCY POWER
2301 CENTRAL AVENUE
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
UNRESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
72
LEAKING STORAGE TANKS (LST)
MAP ID# 43
Distance from Property: 0.44 mi. W
SITE INFORMATION
SITE ID:
2282
SITE NAME:
ADDRESS:
INTERMOUNTAIN SAFETY
1122 WEST 19TH STREET
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
UNRESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NO
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
73
LEAKING STORAGE TANKS (LST)
MAP ID# 44
Distance from Property: 0.45 mi. SW
SITE INFORMATION
SITE ID:
3368
SITE NAME:
ADDRESS:
MESIC'S CONOCO
1131 WEST LINCOLNWAY
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
74
VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF)
MAP ID# 45
Distance from Property: 0.46 mi. E
SITE INFORMATION
SITE NUMBER: 1007
SITE NAME:
ADDRESS:
CHEYENNE VILLAGE INN
411 E. 16TH STREET
CHEYENNE, WY
COUNTY:
LARAMIE
STATUS:
CLOSED
VOLUNTEER:
SITE TYPE:
GULLEY ENTERPRISES
VRP/ICP
VRP ACCEPTANCE DATE: 4/26/2001
PRELIMINARY REMEDIATION AGREEMENT DATE: 5/29/2001 conditional
REMEDY AGREEMENT DATE: NA
LIABILITY ASSURANCE:
NA
VRP PROJECT MANAGER: NOT APPLICABLE
INSTITUTIONAL CONTROL: NO
TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
75
LEAKING STORAGE TANKS (LST)
MAP ID# 46
Distance from Property: 0.50 mi. W
SITE INFORMATION
SITE ID:
3978
SITE NAME:
ADDRESS:
AMERIGAS
1000 WEST 23RD STREET
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
76
LEAKING STORAGE TANKS (LST)
MAP ID# 47
Distance from Property: 0.50 mi. E
SITE INFORMATION
SITE ID:
4307
SITE NAME:
ADDRESS:
VACANT GARAGE - 502 EAST LINCOLNWAY
502 EAST LINCOLNWAY
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
UNRESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: Yes
PRIORITY RANKING: 759
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
77
LEAKING STORAGE TANKS (LST)
MAP ID# 48
Distance from Property: 0.50 mi. N
SITE INFORMATION
SITE ID:
276
SITE NAME:
ADDRESS:
CHEYENNE REGIONAL MEDICAL CENTER
300 EAST 23RD STREET
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
2
CONFIRMED RELEASE DATE: 01/01/87
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
78
VOLUNTARY REMEDIATION PROGRAM AND BROWNFIELD SITES (VRPBF)
MAP ID# 49
Distance from Property: 0.50 mi. NW
SITE INFORMATION
SITE NUMBER: 2029
SITE NAME:
ADDRESS:
2500 BLOCK OF THOMES AVE, CHEYENNE
2500 BLOCK OF THOMES
CHEYENNE, WY
COUNTY:
LARAMIE
STATUS:
OPEN
VOLUNTEER:
SITE TYPE:
STATE OF WY, A & I CONSTRUCTION (FORMERLY SAFEWAY INC.)
VRP
VRP ACCEPTANCE DATE: 6/2/2003
PRELIMINARY REMEDIATION AGREEMENT DATE: NOT REPORTED
REMEDY AGREEMENT DATE: NOT REPORTED
LIABILITY ASSURANCE:
NOT REPORTED
VRP PROJECT MANAGER: AL THOMPSON
INSTITUTIONAL CONTROL: NO
TYPE OF INSTITUTIONAL CONTROL: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
79
LEAKING STORAGE TANKS (LST)
MAP ID# 50
Distance from Property: 0.50 mi. W
SITE INFORMATION
SITE ID:
527
SITE NAME:
ADDRESS:
AMERIGAS CHEYENNE
1021 WEST 23RD STREET
CHEYENNE, WY 82001
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
80
RESOURCE CONSERVATION & RECOVERY ACT - CORRECTIVE ACTION FACILITIES (RCRAC)
MAP ID# 51
Distance from Property: 0.79 mi. W
FACILITY INFORMATION
EPA ID#: WYD988870226
OWNER TYPE: NOT REPORTED
NAME: GLACIER PARK PROPERTY - CHEYENNE
OWNER NAME: NOT REPORTED
ADDRESS: WEST OF B.N. RR YARD 1201 W 27TH ST.
OPERATOR TYPE: NOT REPORTED
OPERATOR NAME: NOT REPORTED
CHEYENNE, WY 82001
CONTACT NAME: NOT REPORTED
CONTACT ADDRESS:
,
CONTACT PHONE: NOT REPORTED
NON-NOTIFIER: NON-NOTIFIER
DATE RECEIVED BY AGENCY: 09/09/1991
INDUSTRY CLASSIFICATION (NAICS)
- NO NAICS INFORMATION REPORTED
SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS)
DATE RECEIVED BY AGENCY: 09/09/91
NAME: GLACIER PARK PROPERTY - CHEYENNE
GENERATOR CLASSIFICATION: NOT A GENERATOR
ACTIVITY INFORMATION
GENERATOR STATUS: NOT A GENERATOR
SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO
TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO
TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO
NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: YES
CORRECTIVE ACTION WORKLOAD UNIVERSE: YES
IMPORTER: NO
UNDERGROUND INJECTION: NO
MIXED WASTE GENERATOR: NO
UNIVERSAL WASTE DESTINATION FACILITY: NO
RECYCLER: NO
TRANSFER FACILITY: NO
TRANSPORTER: NO
USED OIL FUEL BURNER: NO
ONSITE BURNER EXEMPTION: NO
USED OIL PROCESSOR: NO
FURNACE EXEMPTION: NO
USED OIL FUEL MARKETER TO BURNER: NO
USED OIL REFINER: NO
SPECIFICATION USED OIL MARKETER: NO
USED OIL TRANSFER FACILITY: NO
USED OIL TRANSPORTER: NO
COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION
EVALUATIONS
1991/07/15
NRR NON-FINANCIAL RECORD REVIEW
1991/09/09
FUI FOLLOW-UP INSPECTION
VIOLATIONS
1991/07/15
264.N TSD - LANDFILL STANDARDS
ENFORCEMENTS
1991/09/10
320 FINAL IMMINENT HAZARD ORDER
HAZARDOUS WASTE
UNIVERSAL WASTE
NO HAZARDOUS WASTE INFORMATION REPORTED
- NO UNIVERSAL WASTE REPORTED -
CORRECTIVE ACTION AREA
ENTIRE FACILITY
-----
-----
YES
-----
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
81
RESOURCE CONSERVATION & RECOVERY ACT - CORRECTIVE ACTION FACILITIES (RCRAC)
CORRECTIVE ACTION EVENT
CA100
19910910
INVESTIGATION IMPOSITION
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
82
REPORT SUMMARY OF UNLOCATABLE SITES
DATABASE
TYPE
SITE
ID#
SITE
NAME
ADDRESS
CITY
ZIP CODE
LST
3056
CNF TRANSPORTATION
P. O. BOX 2067
CHEYENNE
82009
ST
0-001115
MARVIN BERRY
P. O. BOX 167
CHEYENNE
82009
MERIDEN ROUTE
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
1
LEAKING STORAGE TANKS (LST)
SITE INFORMATION
SITE ID:
3056
SITE NAME:
ADDRESS:
CNF TRANSPORTATION
P. O. BOX 2067
CHEYENNE, WY 82009
SITE DETAILS
TOTAL ACTIVE:
NOT REPORTED
CONFIRMED RELEASE DATE: NOT REPORTED
SITE TYPE:
RESOLVED CONTAMINATED SITE
CORRECTIVE ACTION: NOT REPORTED
PRIORITY RANKING: NOT REPORTED
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
1
STORAGE TANKS (ST)
SITE INFORMATION
SITE ID:
0-001115
SITE NAME:
MARVIN BERRY
P. O. BOX 167
ADDRESS:
MERIDEN ROUTE
CHEYENNE,
WY 82009
SITE DETAILS
TANK ID:
1
DATE INSTALLED:
01-JUL-79
TANK STATUS:
PERMANENTLY OUT OF USE
SUBSTANCES:
DIESEL
TANK CAPACITY:
3000
SPECIFICATION DESCRIPTION: STEEL - UNKNOWN SPECIFICATION
PUMP TYPE DESCRIPTION:
SAFE SUCTION
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
2
ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL
AIRSAFS
Aerometric Information Retrieval System / Air Facility Subsystem
VERSION DATE: 8/2012
The United States Environmental Protection Agency (EPA) modified the Aerometric Information
Retrieval System (AIRS) to a database that exclusively tracks the compliance of stationary sources
of air pollution with EPA regulations: the Air Facility Subsystem (AFS). Since this change in 2001,
the management of the AIRS/AFS database was assigned to EPA's Office of Enforcement and
Compliance Assurance.
Brownfields Management System
BF
VERSION DATE: 4/2013
Brownfields are real property, the expansion, redevelopment, or reuse of which may be
complicated by the presence or potential presence of a hazardous substance, pollutant, or
contaminant. Cleaning up and reinvesting in these properties takes development pressures off of
undeveloped, open land, and both improves and protects the environment. The United States
Environmental Protection Agency maintains this database to track activities in the various brown
field grant programs including grantee assessment, site cleanup and site redevelopment.
BRS
Biennial Reporting System
VERSION DATE: 12/2009
The United States Environmental Protection Agency (EPA), in cooperation with the States,
biennially collects information regarding the generation, management, and final disposition of
hazardous wastes regulated under the Resource Conservation and Recovery Act of 1976 (RCRA),
as amended. The Biennial Report captures detailed data on the generation of hazardous waste
from large quantity generators and data on waste management practices from treatment, storage
and disposal facilities. Currently, the EPA states that data collected between 1991 and 1997 was
originally a part of the defunct Biennial Reporting System and is now incorporated into the
RCRAInfo data system.
CDL
Clandestine Drug Laboratory Locations
VERSION DATE: 3/2012
The U.S. Department of Justice ("the Department") provides this information as a public service. It
contains addresses of some locations where law enforcement agencies reported they found
chemicals or other items that indicated the presence of either clandestine drug laboratories or
dumpsites. In most cases, the source of the entries is not the Department, and the Department
has not verified the entry and does not guarantee its accuracy. Members of the public must verify
the accuracy of all entries by, for example, contacting local law enforcement and local health
departments. The Department does not establish, implement, enforce, or certify compliance with
clean-up or remediation standards for contaminated sites; the public should contact a state or local
health department or environmental protection agency for that information.
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DEFINITIONS 1
ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL
CERCLIS
Comprehensive Environmental Response, Compensation & Liability Information System
VERSION DATE: 12/2012
CERCLIS is the repository for site and non-site specific Superfund information in support of the
Comprehensive Environmental Response, Compensation and Liability Act (CERCLA). This United
States Environmental Protection Agency database contains an extract of sites that have been
investigated or are in the process of being investigated for potential environmental risk.
DNPL
Delisted National Priorities List
VERSION DATE: 12/2012
This database includes sites from the United States Environmental Protection Agency’s Final
National Priorties List (NPL) where remedies have proven to be satisfactory or sites where the
original analyses were inaccurate, and the site is no longer appropriate for inclusion on the NPL,
and final publication in the Federal Register has occurred.
DOCKETS
EPA Docket Data
VERSION DATE: 12/2005
The United States Environmental Protection Agency Docket data lists Civil Case Defendants, filing
dates as far back as 1971, laws broken including section, violations that occurred, pollutants
involved, penalties assessed and superfund awards by facility and location. Please refer to ICIS
database as source of current data.
DOD
Department of Defense Sites
VERSION DATE: 12/2005
This information originates from the National Atlas of the United States Federal Lands data, which
includes lands owned or administered by the Federal government. Army DOD, Army Corps of
Engineers DOD, Air Force DOD, Navy DOD and Marine DOD areas of 640 acres or more are
included.
Federal Engineering Institutional Control Sites
EC
VERSION DATE: 4/2013
This database includes site locations where Engineering and/or Institutional Controls have been
identified as part of a selected remedy for the site as defined by United States Environmental
Protection Agency official remedy decision documents. A site listing does not indicate that the
institutional and engineering controls are currently in place nor will be in place once the remedy is
complete; it only indicates that the decision to include either of them in the remedy is documented
as of the completed date of the document. Institutional controls are actions, such as legal controls,
that help minimize the potential for human exposure to contamination by ensuring appropriate land
or resource use. Engineering controls include caps, barriers, or other device engineering to
prevent access, exposure, or continued migration of contamination.
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DEFINITIONS 2
ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL
ERNSWY
Emergency Response Notification System
VERSION DATE: 12/2012
This National Response Center database contains data on reported releases of oil, chemical,
radiological, biological, and/or etiological discharges into the environment anywhere in the United
States and its territories. The data comes from spill reports made to the U.S. Environmental
Protection Agency, U.S. Coast Guard, the National Response Center and/or the U.S. Department
of Transportation.
FRSWY
Facility Registry System
VERSION DATE: 11/2012
The United States Environmental Protection Agency's Office of Environmental Information (OEI)
developed the Facility Registry System (FRS) as the centrally managed database that identifies
facilities, sites or places subject to environmental regulations or of environmental interest. The
Facility Registry System replaced the Facility Index System or FINDS database.
FUDS
Formerly Used Defense Sites
VERSION DATE: 2/2013
The 2011 FUDS inventory includes properties previously owned by or leased to the United States
and under Secretary of Defense jurisdiction. The remediation of these properties is the
responsibility of the Department of Defense.
HISTPST
Historical Gas Stations
VERSION DATE: 7/1930
This historic directory of service stations is provided by the Cities Service Company. The directory
includes Cities Service filling stations that were located throughout the United States in 1930.
HMIRSR08
Hazardous Materials Incident Reporting System
VERSION DATE: 1/2013
The HMIRS database contains unintentional hazardous materials release information reported to
the U.S. Department of Transportation located in EPA Region 8. This region includes the following
states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming.
ICIS
Integrated Compliance Information System (formerly DOCKETS)
VERSION DATE: 8/2012
ICIS is a case activity tracking and management system for civil, judicial, and administrative federal
Environmental Protection Agency enforcement cases. ICIS contains information on federal
administrative and federal judicial cases under the following environmental statutes: the Clean Air
Act, the Clean Water Act, the Resource Conservation and Recovery Act, the Emergency Planning
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DEFINITIONS 3
ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL
and Community Right-to-Know Act - Section 313, the Toxic Substances Control Act, the Federal
Insecticide, Fungicide, and Rodenticide Act, the Comprehensive Environmental Response,
Compensation, and Liability Act, the Safe Drinking Water Act, and the Marine Protection,
Research, and Sanctuaries Act.
ICISNPDES
VERSION DATE: 8/2012
Integrated Compliance Information System National Pollutant Discharge Elimination
System
In 2006, the Integrated Compliance Information System (ICIS) - National Pollutant Discharge
Elimination System (NPDES) became the NPDES national system of record for select states, tribes
and territories. ICIS-NPDES is an information management system maintained by the United
States Environmental Protection Agency's Office of Compliance to track permit compliance and
enforcement status of facilities regulated by the NPDES under the Clean Water Act. ICIS-NPDES
is designed to support the NPDES program at the state, regional, and national levels.
LUCIS
Land Use Control Information System
VERSION DATE: 9/2006
The LUCIS database is maintained by the U.S. Navy and contains information for former Base
Realignment and Closure (BRAC) properties across the United States.
MLTS
Material Licensing Tracking System
VERSION DATE: 1/2013
MLTS is a list of approximately 8,100 sites which have or use radioactive materials subject to the
United States Nuclear Regulatory Commission (NRC) licensing requirements.
NFRAP
No Further Remedial Action Planned Sites
VERSION DATE: 12/2012
This database includes sites which have been determined by the United States Environmental
Protection Agency, following preliminary assessment, to no longer pose a significant risk or require
further activity under CERCLA. After initial investigation, no contamination was found,
contamination was quickly removed or contamination was not serious enough to require Federal
Superfund action or NPL consideration.
NLRRCRAC
No Longer Regulated RCRA Corrective Action Facilities
VERSION DATE: 3/2013
This database includes RCRA Corrective Action facilities that are no longer regulated by the United
States Environmental Protection Agency or do not meet other RCRA reporting requirements.
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DEFINITIONS 4
ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL
NLRRCRAG
No Longer Regulated RCRA Generator Facilities
VERSION DATE: 3/2013
This database includes RCRA Generator facilities that are no longer regulated by the United States
Environmental Protection Agency or do not meet other RCRA reporting requirements. This listing
includes facilities that formerly generated hazardous waste.
Large Quantity Generators: Generate 1,000 kg or more of hazardous waste during any calendar
month; or Generate more than 1 kg of acutely hazardous waste during any calendar month; or
Generate more than 100 kg of any residue or contaminated soil, waste or other debris resulting
from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any
calendar month; or Generate 1 kg or less of acutely hazardous waste during any calendar month,
and accumulate more than 1kg of acutely hazardous waste at any time; or Generate 100 kg or less
of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into
or on any land or water, of acutely hazardous waste during any calendar month, and accumulated
more than 100 kg of that material at any time.
Small Quantity Generators: Generate more than 100 and less than 1000 kilograms of hazardous
waste during any calendar month and accumulate less than 6000 kg of hazardous waste at any
time; or Generate 100 kg or less of hazardous waste during any calendar month, and accumulate
more than 1000 kg of hazardous waste at any time.
Conditionally Exempt Small Quantity Generators: Generate 100 kilograms or less of hazardous
waste per calendar month, and accumulate 1000 kg or less of hazardous waste at any time; or
Generate one kilogram or less of acutely hazardous waste per calendar month, and accumulate at
any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated
soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or
acutely hazardous waste; or Generate 100 kg or less of any residue or contaminated soil, waste or
other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous
waste during any calendar month, and accumulate at any time: 1 kg or less of acutely hazardous
waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from
the cleanup of a spill, into or on any land or water, of acutely hazardous waste.
NLRRCRAT
No Longer Regulated RCRA Non-CORRACTS TSD Facilities
VERSION DATE: 3/2013
This database includes RCRA Non-Corrective Action TSD facilities that are no longer regulated by
the United States Environmental Protection Agency or do not meet other RCRA reporting
requirements. This listing includes facilities that formerly treated, stored or disposed of hazardous
waste.
NPDESR08
National Pollutant Discharge Elimination System
VERSION DATE: 4/2007
Information in this database is extracted from the Water Permit Compliance System (PCS)
database which is used by United States Environmental Protection Agency to track surface water
permits issued under the Clean Water Act. This database includes permitted facilities located in
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DEFINITIONS 5
ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL
EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South
Dakota, Utah, and Wyoming. The NPDES database was collected from December 2002 until April
2007. Refer to the PCS and/or ICIS-NPDES database as source of current data.
NPL
National Priorities List
VERSION DATE: 12/2012
This database includes United States Environmental Protection Agency (EPA) National Priorities
List sites that fall under the EPA's Superfund program, established to fund the cleanup of the most
serious uncontrolled or abandoned hazardous waste sites identified for possible long-term remedial
action.
Open Dump Inventory
ODI
VERSION DATE: 6/1985
The open dump inventory was published by the United States Environmental Protection Agency.
An “open dump” is defined as a facility or site where solid waste is disposed of which is not a
sanitary landfill which meets the criteria promulgated under section 4004 of the Solid Waste
Disposal Act (42 U.S.C. 6944) and which is not a facility for disposal of hazardous waste. This
inventory has not been updated since June 1985.
PADS
PCB Activity Database System
VERSION DATE: 11/2012
The PCB Activity Database System (PADS) is used by the United States Environmental Protection
Agency to monitor the activities of polychlorinated biphenyls (PCB) handlers.
PCSR08
Permit Compliance System
VERSION DATE: 8/2012
The Permit Compliance System is used in tracking enforcement status and permit compliance of
facilities controlled by the National Pollutant Discharge Elimination System (NPDES) under the
Clean Water Act and is maintained by the United States Environmental Protection Agency's Office
of Compliance. PCS is designed to support the NPDES program at the state, regional, and
national levels. This database includes permitted facilities located in EPA Region 8. This region
includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and
Wyoming.
PNPL
Proposed National Priorities List
VERSION DATE: 12/2012
This database contains sites proposed to be included on the National Priorities List (NPL) in the
Federal Register. The United States Environmental Protection Agency investigates these sites to
determine if they may present long-term threats to public health or the environment.
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DEFINITIONS 6
ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL
RCRAC
Resource Conservation & Recovery Act - Corrective Action Facilities
VERSION DATE: 3/2013
This database includes hazardous waste sites listed with corrective action activity in the RCRAInfo
system. The Corrective Action Program requires owners or operators of RCRA facilities (or
treatment, storage, and disposal facilities) to investigate and cleanup contamination in order to
protect human health and the environment. The United States Environmental Protection Agency
defines RCRAInfo as the comprehensive information system which provides access to data
supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and
Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting
abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial
Reporting System (BRS).
RCRAGR08
Resource Conservation & Recovery Act - Generator Facilities
VERSION DATE: 3/2013
This database includes sites listed as generators of hazardous waste (large, small, and exempt) in
the RCRAInfo system. The United States Environmental Protection Agency defines RCRAInfo as
the comprehensive information system which provides access to data supporting the Resource
Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments
(HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource
Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System
(BRS). This database includes sites located in EPA Region 8. This region includes the following
states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming.
Large Quantity Generators: Generate 1,000 kg or more of hazardous waste during any calendar
month; or Generate more than 1 kg of acutely hazardous waste during any calendar month; or
Generate more than 100 kg of any residue or contaminated soil, waste or other debris resulting
from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any
calendar month; or Generate 1 kg or less of acutely hazardous waste during any calendar month,
and accumulate more than 1kg of acutely hazardous waste at any time; or Generate 100 kg or less
of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into
or on any land or water, of acutely hazardous waste during any calendar month, and accumulated
more than 100 kg of that material at any time.
Small Quantity Generators: Generate more than 100 and less than 1000 kilograms of hazardous
waste during any calendar month and accumulate less than 6000 kg of hazardous waste at any
time; or Generate 100 kg or less of hazardous waste during any calendar month, and accumulate
more than 1000 kg of hazardous waste at any time.
Conditionally Exempt Small Quantity Generators: Generate 100 kilograms or less of hazardous
waste per calendar month, and accumulate 1000 kg or less of hazardous waste at any time; or
Generate one kilogram or less of acutely hazardous waste per calendar month, and accumulate at
any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated
soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or
acutely hazardous waste; or Generate 100 kg or less of any residue or contaminated soil, waste or
other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DEFINITIONS 7
ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL
waste during any calendar month, and accumulate at any time: 1 kg or less of acutely hazardous
waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from
the cleanup of a spill, into or on any land or water, of acutely hazardous waste.
RCRASC
RCRA Sites with Controls
VERSION DATE: 6/2012
This list of Resource Conservation and Recovery Act sites with institutional controls in place is
provided by the U.S. Environmental Protection Agency.
RCRAT
Resource Conservation & Recovery Act - Treatment, Storage & Disposal Facilities
VERSION DATE: 3/2013
This database includes Non-Corrective Action sites listed as treatment, storage and/or disposal
facilities of hazardous waste in the RCRAInfo system. The United States Environmental Protection
Agency defines RCRAInfo as the comprehensive information system which provides access to
data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous
and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and
reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and
the Biennial Reporting System (BRS).
RODS
Record of Decision System
VERSION DATE: 1/2013
These decision documents maintained by the United States Environmental Protection Agency
describe the chosen remedy for NPL (Superfund) site remediation. They also include site history,
site description, site characteristics, community participation, enforcement activities, past and
present activities, contaminated media, the contaminants present, and scope and role of response
action.
SFLIENS
CERCLIS Liens
VERSION DATE: 6/2012
A Federal CERCLA ("Superfund") lien can exist by operation of law at any site or property at which
United States Environmental Protection Agency has spent Superfund monies. These monies are
spent to investigate and address releases and threatened releases of contamination. CERCLIS
provides information as to the identity of these sites and properties. This database contains those
CERCLIS sites where the Lien on Property action is complete.
SSTS
Section Seven Tracking System
VERSION DATE: 12/2009
The United States Environmental Protection Agency tracks information on pesticide establishments
through the Section Seven Tracking System (SSTS). SSTS records the registration of new
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DEFINITIONS 8
ENVIRONMENTAL RECORDS DEFINITIONS - FEDERAL
establishments and records pesticide production at each establishment. The Federal Insecticide,
Fungicide and Rodenticide Act (FIFRA) requires that production of pesticides or devices be
conducted in a registered pesticide-producing or device-producing establishment. ("Production"
includes formulation, packaging, repackaging, and relabeling.)
Toxics Release Inventory
TRI
VERSION DATE: 12/2011
The Toxics Release Inventory, provided by the United States Environmental Protection Agency,
includes data on toxic chemical releases and waste management activities from certain industries
as well as federal facilities. This inventory contains information about the types and amounts of
toxic chemicals that are released each year to the air, water, and land as well as information on the
quantities of toxic chemicals sent to other facilities for further waste management.
TSCA
Toxic Substance Control Act Inventory
VERSION DATE: 12/2006
The Toxic Substances Control Act (TSCA) was enacted in 1976 to ensure that chemicals
manufactured, imported, processed, or distributed in commerce, or used or disposed of in the
United States do not pose any unreasonable risks to human health or the environment. TSCA
section 8(b) provides the United States Environmental Protection Agency authority to "compile,
keep current, and publish a list of each chemical substance that is manufactured or processed in
the United States." This TSCA Chemical Substance Inventory contains non-confidential
information on the production amount of toxic chemicals from each manufacturer and importer site.
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DEFINITIONS 9
ENVIRONMENTAL RECORDS DEFINITIONS - STATE (WY)
Sites with Institutional Controls in Place
IC
VERSION DATE: 12/2012
As defined by the Wyoming Department of Environmental Quality (DEQ), institutional controls are
legal or administrative measures that limit human exposure to contaminants. Examples include use
control areas, easements, zoning restrictions, and deed notices. They are intended to bolster the
integrity of remedies and minimize the potential exposure to contamination by limiting land or
resource use. This list of sites with institutional controls in place is provided by the DEQ’s
Voluntary Remediation Program.
LST
Leaking Storage Tanks
VERSION DATE: 1/2013
This listing of active storage tank facilities with contamination is provided by the Wyoming
Department of Environmental Quality’s Storage Tank Program (STP). According to Wyoming
Statues 35-11-1414 through 35-11-1428, the state is responsible for remediation of releases from
regulated underground storage tanks and certain aboveground storage tanks. The STP rules and
regulations apply to all regulated storage tanks in Wyoming. Storage tank owners/operators are
entitled to the state corrective action program if they register their tank(s), pay applicable fees, and
complete a minimum site assessment (if applicable). State management of remediation is optional
for owners; however, almost no tank system owners have elected to complete cleanup at their
expense.
ORPHANS
Orphan Sites
VERSION DATE: 1/2013
The Orphan Site listing is provided by the Wyoming Department of Environmental Quality (DEQ).
Under the Environmental Quality Act “Orphan Sites” are defined as: Sites where the DEQ
determines that there is no viable party that is responsible for causing or contributing to the
contamination present at the site; Sites where DEQ has issued a no further action letter, and where
there is a subsequent discovery of contamination which was present at the site when the no further
action letter was issued; Spill sites, where DEQ determines that the person responsible for the spill
cannot be identified or where DEQ must take prompt action to prevent hazards to human health or
the environment at a site where a responsible party fails to act promptly.
Storage Tanks
ST
VERSION DATE: 1/2013
This listing contains active and inactive storage tank facilities regulated by the Wyoming
Department of Environmental Quality’s Storage Tank Program (STP). The STP regulates
underground storage tanks (USTs) that contain petroleum or hazardous substances; USTs that are
larger than 110 gallons or 1,100 gallons on a farm, ranch, or residence; and those that are not
heating oil tanks. The STP regulates aboveground storage tanks (ASTs) only if they contain
gasoline or diesel, and they are used by a fuel dealer to directly fuel vehicles. The STP does not
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DEFINITIONS 10
ENVIRONMENTAL RECORDS DEFINITIONS - STATE (WY)
regulate septic tanks, water storage tanks, hazardous substance ASTs, heating oil tanks, bulk
plants, oil refineries, interstate pipeline breakout tanks, or temporary construction ASTs.
SWF
Permitted Solid Waste Facilities
VERSION DATE: 8/2012
This listing of permitted solid waste facilities is provided by the Solid and Hazardous Waste Division
(SHWD) of the Wyoming Department of Environmental Quality. The SHWD’s Solid Waste and
Permitting Corrective Action Program is responsible for permitting the location, design,
construction, operation, monitoring, closure and post-closure care and remediation of solid waste
management facilities. The solid waste facilities that are regulated by this program include local
community landfills (both operating and closed), municipal waste baling stations and transfer
facilities, industrial waste landfills, industrial waste treatment facilities and units, and used oil
storage facilities.
VRPBF
Voluntary Remediation Program and Brownfield Sites
VERSION DATE: 12/2012
Wyoming’s Voluntary Remediation Program (VRP) was created by the Wyoming Legislature in
2000 to create new opportunities, procedures, standards and incentives for voluntary remediation
of contaminated properties. In order to encourage more people to participate in the VRP, the
Wyoming Department of Environmental Quality (DEQ) obtained a grant from the U.S.
Environmental Protection Agency to provide technical assistance (Brownfields Assistance) at
brownfield properties that are eligible to participate in Wyoming’s VRP. This DEQ listing contains
both VRP and Brownfield properties.
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DEFINITIONS 11
ENVIRONMENTAL RECORDS DEFINITIONS - TRIBAL
INDIANRES
Indian Reservations
VERSION DATE: 1/2000
The Department of Interior and Bureau of Indian Affairs maintains this database that includes
American Indian Reservations, off-reservation trust lands, public domain allotments, Alaska Native
Regional Corporations and Recognized State Reservations.
LUSTR08
Leaking Underground Storage Tanks On Tribal Lands
VERSION DATE: 2/2013
This database, provided by the United States Environmental Protection Agency (EPA), contains
leaking underground storage tanks on Tribal lands located in EPA Region 8. This region includes
the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming.
ODINDIAN
Open Dump Inventory on Tribal Lands
VERSION DATE: 11/2006
This Indian Health Service database contains information about facilities and sites on tribal lands
where solid waste is disposed of, which are not sanitary landfills or hazardous waste disposal
facilities, and which meet the criteria promulgated under section 4004 of the Solid Waste Disposal
Act (42 U.S.C. 6944).
USTR08
Underground Storage Tanks On Tribal Lands
VERSION DATE: 2/2013
This database, provided by the United States Environmental Protection Agency (EPA), contains
underground storage tanks on Tribal lands located in EPA Region 8. This region includes the
following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming.
www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967
DEFINITIONS 12
APPENDIX E
SITE PHOTOGRAPHS
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705
Photo 1
View is south of floor drain on
west end of basement.
Photo 3
View of body repair anchors in
north end of west portion of
basement.
Reliable ■ Responsive ■ Resourceful
Photo 2
View is east of filled in floor drain
in west portion of basement.
Photo 4
View is north of oil-water
separator in basement.
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705
Photo 5
View of storm water sump in
southwest corner of west portion
of basement.
Photo 7
Transmission fluid stain in south
end of west portion of basement.
Reliable ■ Responsive ■ Resourceful
Photo 6
View of sanitary sewer sump in
southwest corner of west portion
of basement.
Photo 8
View of large stain in south end of
west portion of basement.
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705
Photo 9
View of footer cut along the south
wall of the ramp into the basement
in the west portion of the
basement.
Photo 11
View of groundwater sump in the
Body Parts room in the east
portion of the basement.
Reliable ■ Responsive ■ Resourceful
Photo 10
View is north of re-plumbing floor
cuts to sanitary sewer sump in
northwest corner of east portion of
basement.
Photo 12
View is east of east portion of
basement.
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705
Photo 13
Photo 15
View is north of groundwater
sump along north wall of east
portion of basement.
View is west of floor drain and
exhaust system through east
portion of first floor.
Reliable ■ Responsive ■ Resourceful
Photo 14
View of footer cut along south wall
of east portion of first floor.
Photo 16
View is south of oil-water
separator in east portion of first
floor.
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705
Photo 17
View is east of sand trap in east
portion of first floor.
Photo 19
Floor penetration for underground
hydraulic hoist used in east
portion of first floor.
Reliable ■ Responsive ■ Resourceful
Photo 18
Floor penetration for aboveground
electric hoists used in east portion
of first floor.
Photo 20
View is northwest of east
northwest end of east portion of
first floor showing floor drains.
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705
Photo 21
View of showroom in west portion
of first floor.
Photo 22
View is south of roof top parking
on west portion of building.
Photo 23
View is east of roof of east portion
of building.
Photo 24
View is southeast of west parking
lot.
Photo 25
View is southeast of east parking
lot.
Photo 26
Northwest adjoining property.
Reliable ■ Responsive ■ Resourceful
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705
Photo 27
North adjoining property.
Photo 29
East adjoining properties.
Reliable ■ Responsive ■ Resourceful
Photo 28
North and northwest adjoining
properties.
Photo 30
Site building and attached south
adjoining property.
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705
East parking lot of site and
neighboring south adjoining
property.
Photo 32
South adjoining property.
Photo 33
Southwest adjoining property.
Photo 34
West adjoining property.
Photo 35
West adjoining property.
Photo 36
View is east of site building.
Photo 31
Reliable ■ Responsive ■ Resourceful
Phase I Environmental Site Assessment
New Cheyenne Public Safety Center ■ Cheyenne, WY
Photos Taken: 04/30/3013 ■ Terracon Project No. 24137705
Photo 37
View is southeast of site building.
Reliable ■ Responsive ■ Resourceful
APPENDIX F
CREDENTIALS
CLAY MUIRHEAD, P.E.
SENIOR ENVIRONMENTAL ENGINEER,
PRINCIPAL & ENVIRONMENTAL MANAGER
PROFESSIONAL EXPERIENCE
Mr. Muirhead has over 20 years of experience in environmental
engineering, due diligence services (Phase I and II Environmental Site
Assessments), Federal Brownfields and Wyoming Voluntary Remediation
Program assessments, solid waste engineering, and construction
management. He is a principal and manager of environmental services in
Terracon’s Cheyenne office.
PROJECT EXPERIENCE – Environmental Site Assessments
• Phase I and II Environmental Site Assessments, Various Sites Wyoming, Colorado and Nebraska
Performed Phase I Environmental Site Assessments on various
commercial, industrial and agricultural properties and facilities located
throughout Wyoming, Colorado and Nebraska. Clients have included
Albertson’s, American National Bank, Cheyenne LEADS, City of
Cheyenne, Community First National Bank, Cracker Barrel Restaurants,
Gundle, Halladay Motors, Koll Telecommunications, McLeod USA, New
Frontier Bank, Sierra Trading Post, Simon Contractors, U.S. Bank, VAE
Nortrak, Volk Real Estate, Wal-Mart, Wendy’s Restaurants, Wyoming
Association of Municipalities, Wyoming Bank and Trust, and more. Phase
II ESA’s performed on several.
• Voluntary Remediation Program Assessment, Cheyenne Transit
Facility – Cheyenne, Wyoming
Project Manager for Wyoming Voluntary Remediation Program
assessment of historic dump site in Cheyenne, WY for development of
the site as a transit bus facility. Project included a subsurface site
characterization, public meetings, risk assessment and mitigation
alternatives.
• Brownfield Pilot Assessment, Historic Railroad Roundhouse –
Evanston, Wyoming
Project Manager for Federal EPA Brownfield Pilot Assessment of historic
railroad roundhouse. Project included environmental site assessments,
public meetings, human health and ecological risk assessments, and
evaluation of mitigation alternatives.
• Environmental Feasibility Analysis, Wind Energy Project - Reno
Junction, Wyoming
Project Manager for environmental feasibility analysis for proposed wind
energy project near Reno Junction, WY for Third Planet Windpower.
Project included review and mapping of published information for site
geotechnical and geological hazards, wetlands, threatened and
endangered species, and historic and archeological resources.
• WDEQ Subdivision Applications, Various Sites - Laramie County
and Platte County, Wyoming
Project Manager for various subdivision applications to develop
residential subdivisions in which on-site water supply and waste water
systems were proposed under the Wyoming Department of
Environmental Quality Subdivision Program. The applications included a
subsurface soil and groundwater assessment, aquifer testing, and an
evaluation of the nitrate impact from the proposed waste water systems.
EDUCATION
Master of Business Administration,
1987, University of Denver
Bachelor of Science, Civil
Engineering, 1985, University of
Wyoming
REGISTRATIONS
Professional Engineer: Wyoming
CERTIFICATIONS
40-Hour OSHA Hazardous Waste
Operations Training
Nuclear Density Gauge Safety
Training
Radiation Safety Training: X-ray
Fluorescence Analyzer
AFFILIATIONS
Cheyenne-Laramie County
Corporation for Economic
Development (LEADS)
Greater Cheyenne Chamber of
Commerce
Wyoming Engineering Society
(WES)
Wyoming Solid Waste and
Recycling Association
(WSWRA), Board Member and
Past President
Cheyenne Household Hazardous
Waste Collection Committee
(CH2WC2), Charter Board
Member and Publicity Chairman
WORK HISTORY
Terracon, Environmental Engineer,
1996-present
City of Cheyenne, Solid Waste
Engineer, 1992-1995
Edward’s Construction, Inc.,
Estimator/Project Manager,
1991-1992
Homer J. Olsen, Inc., Civil
Engineer, 1989-1991
H.J. Stabile and Son, Inc.,
Estimator, 1987-1989
MUIRHEAD, CLAY 2
PROJECT EXPERIENCE – Environmental Engineering
• Operation and Maintenance of Remedial Systems for Leaking Underground Storage Tank Sites –
Cheyenne and Rock Springs, WY
Project Manager for operation and maintenance of groundwater and vadose zone remedial systems for
leaking underground storage tank sites (gasoline and diesel) in Cheyenne and Rock Springs Wyoming.
Client is Wyoming Department of Environmental Quality Storage Tank Program. Remedial systems include
groundwater extraction, soil vapor extraction, duel phase vapor extraction and air sparge.
PROJECT EXPERIENCE – Landfill Siting, Permitting and Design
• Variance Application, Lateral Expansion Design, and Permit Application, Eastern Laramie County
Solid Waste Disposal District Landfill - Burns, WY
Manager for landfill design and permit application project for a lateral and vertical expansion to the Burns
Landfill. Prior to the design, Terracon completed a variance application to expand within the prohibited
siting Project distance from an occupied dwelling and water well. The project includes a subsurface
characterization, public meetings, and a design that is sensitive to the concerns of adjacent landowners.
• Title V Air Quality Permit Applications, Casper Regional Landfill and Casper Balefill – Casper, WY
Project Manager for preparation of Title V Air Quality Permit Applications for the Casper Regional Landfill
and Casper Balefill. Projects included categorization and summary of landfill and balefill point source
emissions, process flow diagrams, emissions inventories using the EPA Landfill Gas Emission Model, and
WDEQ/Air Quality Division (AQD) permit applications.
• Siting, Permitting and Design of New Landfill – Cheyenne, Wyoming
Project Manager for politically sensitive, multi-year project for siting, permitting and design of new municipal
solid waste landfill for Cheyenne and Western Laramie County, WY. The project included coordination of a
team of professionals, preparation and execution of a public participation plan, consultation with a public
advisory committee appointed by the Mayor, geographic information system (GIS) siting study, geotechnical
and multi-aquifer hydrogeological investigation, biological and cultural resource surveys, landfill design with
leak detection system, permit application, and construction cost estimates.
• Design of Phase III of North Trench, Cheyenne Sanitary Landfill – Cheyenne, Wyoming
Project Manager for landfill cell design project for the Cheyenne Sanitary Landfill. Project included a
subsurface investigation, liner materials alternative evaluation, surface water drainage design, leachate
collection system design, engineered containment system design, contractor bidding services and
construction quality assurance services.
• Leachate System Design and Management, Cheyenne Sanitary Landfill – Cheyenne, Wyoming
Project Manager for leachate system design and management projects for the Cheyenne Sanitary Landfill.
Projects included preparation of long-term leachate management plan; storm water and leachate
calculations, Hydrologic Evaluation of Landfill Performance (HELP) modeling, underground leachate
pipeline design, leachate evaporation pond design, and construction quality assurance (CQA) services.
• Alternative Earthen Final Cover Assessment, Cheyenne Sanitary Landfill – Cheyenne, Wyoming
Project Manager for alternative earthen final cover (AEFC) feasibility assessment at the Cheyenne Landfill.
Project included soil testing and analysis of on site soils, and modeling to compare and evaluate an AEFC
with a WDEQ prescriptive final cover system.
• Landfill Cap Design, Cheyenne Sanitary Landfill – Cheyenne, Wyoming
Project Manager for landfill cap design, surface water run-off design, and construction quality control for the
South Trench Cells at the Cheyenne Sanitary Landfill. The cap design utilized a high density polyethylene
(HDPE) liner system.
• Environmental Compliance Engineering, Cheyenne Sanitary Landfill – Cheyenne, Wyoming
Project Manager for comprehensive, multi-year landfill engineering project at the Cheyenne Landfill that
included a permit renewal application, creek channel realignment permit with U.S. Army Corps of Engineers
and WDEQ, preliminary landfill expansion / new landfill development evaluation citizen landfill advisory
committee, multi-aquifer hydrogeologic investigation, vertical expansion design, and Tier 1 NMOC emission
rate assessment.
MUIRHEAD, CLAY 3
PROJECT EXPERIENCE – Landfill Environmental Monitoring
• Environmental Monitoring and Reporting, Casper Regional Landfill and Casper Balefill – Casper, WY
Project Manager for multi-year environmental monitoring and reporting projects for Casper Regional Landfill
and Casper Balefill. Projects include updating the facility environmental monitoring plans, quality control
(QC) review of groundwater sampling data and laboratory results, groundwater data reduction and
statistical analysis, landfill gas emission rate calculations and air quality reporting, aerial photography and
mapping, volumetric calculations, and quarterly and annual groundwater quality and air emissions reports.
• Post Closure Monitoring, Base Landfills - F.E. Warren Air Force Base, Wyoming
Project Manager for post closure monitoring project at three landfill sites at F.E. Warren Air Force Base in
Cheyenne, Wyoming for the Air Force Center for Environmental Excellence (AFCEE). The project included
groundwater, surface water, and methane sampling. Micropurge and diffusion sampling technology used for
groundwater sampling.
PROJECT EXPERIENCE – Solid Waste Transfer Stations and Recycling Facilities
• Transfer Station Permit Application and Household Hazardous Waste Facility Design – City of
Cheyenne Transfer Station
Project Manager for Wyoming Department of Environmental Quality solid waste permit application for the
Felix Pino Transfer Station in Cheyenne, WY. The project included the design and permitting of a
permanent household hazardous waste (HHW) facility at the transfer station.
• Transfer Station Permit Application, City of Casper Solid Waste Transfer Facility – Casper, Wyoming
Project Manager for Wyoming Department of Environmental Quality solid waste permit renewal application
for the City of Casper Solid Waste Transfer Facility in Casper, WY. The facility is the largest municipal solid
waste (MSW) baling facility in WY and includes a sophisticated scale house, multi-level baling facility,
compost facility, household hazardous waste (HHW) facility, and recycling center.
• Solid Waste Baler Evaluation and Replacement, Casper Balefill – Casper, Wyoming
Project Manager on multi-year baler evaluation and replacement project for the Casper Balefill Transfer
Station. Project includes research of solid waste baling and bale bag/wrapping equipment, tours of select
solid waste baling facilities throughout the United States, equipment cost estimates, building modifications,
bid specifications, bidding services, and construction quality assurance (CQA) services.
• E-Waste Recycling Facility Permit Application, Tatooine Electronic Systems - Cheyenne, WY
Project Manager for first electronic waste (e-waste) recycling facility permit from Wyoming Department of
Environmental Quality (WDEQ). Project included negotiations with WDEQ to develop standards for e-waste
recycling facilities, preparation of a permit application for approval by the WDEQ, and public meetings.
ADDITIONAL COURSES
Senior Leadership Course, Terracon Consultants, Inc., Olathe, Kansas.
Fundamentals of Professional Practice, ASFE, Kansas City, Kansas.
Designing and Implementing Alternative Earthen Final Covers for Waste Containment Facilities, University of
Wisconsin, Held at University of California, Los Angeles (UCLA).
Fundamentals of Groundwater Contamination and Remediation Techniques, University of Wisconsin,
Madison, Wisconsin.
Sanitary Landfill Design, University of Wisconsin, Madison, Wisconsin.