Item # 16 - the City of Vaughan
Transcription
Item # 16 - the City of Vaughan
Item # 16 Ward #5 File: A250/15 Applicant: CARYL ROSMAN Address: 19 Windhaven Terrace, Thornhill Agent: RAYMOND ROBERTSON Adjournment Status: Notes: Comments/Conditions: Commenting Department Building Standards Development Planning Engineering TRCA PowerStream Ministry of Transportation York Region Other - _______________________ Legend: Comment Condition of Approval - Positive Comment - Negative Comment Prepared By: Pravina Attwala COMMITTEE OF ADJUSTMENT 2141 Major Mackenzie Drive, Vaughan, Ontario, L6A 1T1 Tel [905] 832-2281 Fax [905] 832-8535 NOTICE OF APPLICATION MINOR VARIANCE FILE NUMBER: A250/15 APPLICANT: CARYL ROSMAN PROPERTY: Part of Lot 33, Concession 1 (Lot 15, Registered Plan 65M-2912) municipally known as 19 Windhaven Terrace, Thornhill. ZONING: The subject lands are zoned R2, Residential Zone 2 under By-law 1-88 as amended. PURPOSE: To permit the construction of pool equipment, air conditioning unit and a garden shed as follows: PROPOSAL: 1. To permit a minimum interior side yard setback of 0.3 metres to pool equipment. 2. To permit a minimum interior side yard setback of 0.3 metres to an A/C unit. 3. To permit an accessory structure (garden shed) with a maximum height of 3.0 metres. BY-LAW REQUIREMENT: 1. A minimum interior side yard setback of 1.2 metres is required. 2. A minimum interior side yard setback of 1.2 metres is required. 3. A maximum height of 2.5 metres is permitted. A sketch is attached illustrating the request. This application will be heard by the Committee of Adjustment on the date and time shown below. DATE: THURSDAY, AUGUST 27, 2015 TIME: 6:00 PM LOCATION: COMMITTEE ROOM 242/243 (2nd Floor) VAUGHAN CITY HALL 2141 MAJOR MACKENZIE DRIVE VAUGHAN, ONTARIO L6A 1T1 You are invited to attend this public hearing in person to express your views about this application or you may be represented by counsel for that purpose. If you do not attend at the hearing it may proceed in your absence and, except as otherwise provided in the Planning Act, you will not be entitled to any further notice of the proceedings. If you wish to be notified of the decision of the Committee of Adjustment with respect to this application, you must complete the attached “Request for Decision” form and submit it to the Secretary-Treasurer. Additional information is available from the Committee of Adjustment staff between 8:30 a.m. and 4:30 p.m. Monday to Friday at the Committee of Adjustment, Clerks Department: Tel:(905) 832-8585/Fax: (905) 832-8535. If you wish to make written comments on this application they may be forwarded to the Secretary - Treasurer of the Committee of Adjustment PRIOR TO THE MEETING. Your comments are collected under the legal authority of the Planning Act, R.S.O. 1990,Chapter c. P.13, as amended. Your comments in respect to this application becomes the property of the City of Vaughan and will become part of the decision making process of the application as noted on this form. Pursuant to Section 27 of the Municipal Freedom of Information and Protection of Privacy Act, R.S.O. 1990, c. M.56, as amended, public feedback to planning proposals is considered to be a public record and will be disclosed to any individual (including being posted on the internet) upon request in accordance with Section 27 of the Municipal Freedom of Information and Protection Privacy Act, R.S.O. 1990, c. M.56, as amended. Questions about this collection should be directed to the Secretary-Treasurer, Vaughan Committee of Adjustment, Clerk’s Department, 2141 Major Mackenzie Drive, Vaughan, Ontario; L6A 1T1 (905) 832-8585 x.8332. th DATED THIS 12 DAY OF AUGUST, 2015. Todd Coles, BES, MCIP, RPP Manager of Development Services and Secretary-Treasurer to Committee of Adjustment Agenda packages will be available prior to the hearing at: Vaughan.ca/CofA Form 9 Revised Sketch - Aug 5/15 0.3M A250/15 A250/15 0.3M Location Map -A250/15 19 Windhaven Terrace, Thornhill BATHURST STREET HIGHWAY #7 ± City of Vaughan 0 0.015 0.03 0.06 Kilometers The City of Vaughan makes every effort to ensure that this map is free of errors but does not warrant that the map or its features are spatially, tabularly, or temporally accurate or fit for a particular use. This map is provided by the City of Vaughan witthout warranties of any kind, either expressed or implied. APPLICATION & SKETCH REVISED TO CONCUR WITH BUILDING COMMENTS APPLICATION & SKETCH REVISED TO CONCUR WITH BUILDING COMMENTS XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXX X Revised Sketch - Aug 5/15 0.3M A250/15 A250/15 0.3M 2141 Major Mackenzie Drive Vaughan, Ontario Canada L6A 1T1 Tel (905) 832-2281 To: From: Date: Name of Owner: Location: File No: Committee of Adjustment Brandon Correia, Building Standards Department August 4, 2015 Caryl Rosman 19 Windhaven Terrace; Lot 15, 65M-2912 A250/15 RECEIVED August 4, 2015 VAUGHAN COMMITTEE OF ADJUSTMENT Zoning Classification: The subject lands are zoned R2, Residential Zone 2 under By-law 1-88 as amended. Proposal: 1. 2. 3. To permit a minimum interior side yard setback of 0.3 metres to pool equipment. To permit a minimum interior side yard setback of 0.3 metres to an A/C unit. To permit an accessory structure (garden shed) with a maximum height of 3.0 metres. By-Law Requirements: 1. 2. 3. A minimum interior side yard setback of 1.2 metres is required. A minimum interior side yard setback of 1.2 metres is required. A maximum height of 2.5 metres is permitted. Staff Comments: Stop Work Orders and Orders to Comply: There are no outstanding Orders on file. Building Permits Issued: A building permit has not been issued. The Ontario Building Code requires a building permit for structures that exceed 10m2. Other Comments: Conditions of Approval: If the committee finds merit in the application, the following conditions of approval are recommended. None. * Comments are based on the review of documentation supplied with this application. Page 1 of 1 DATE: August 18, 2015 TO: Todd Coles, Committee of Adjustment FROM: Grant Uyeyama, Director of Development Planning MEETING DATE: August 27, 2015 OWNER: Caryl Rosman FILE(S): A250/15 Location: Proposal: 19 Windhaven Terrace, Vaughan Ward 5, Vicinity of Regional Road No. 7 and Bathurst Street The Owner is requesting permission to maintain an existing A/C unit and to construct a garden shed and pool equipment with the following variances: 1 2 3 Variance Minimum Interior Side Yard Setback to pool equipment Minimum Interior Side Yard Setback to A/C unit Maximum Height of Accessory Structure (garden shed) Proposed 0.3 m Required 1.2 m 0.3 m 1.2 m 3.0 m 2.5 m Official Plan: The subject lands are designated “Low-Rise Residential” by City of Vaughan Official Plan 2010 (VOP 2010). The proposal conforms to the policies of the Official Plan. Comments: Planning Department Staff conducted a site visit with photo documentation on August 12, 2015. The subject lands are developed with a one-storey single detached dwelling with an existing deck and garden shed in the rear yard. The Development Engineering and Infrastructure Planning Services Department has indicated no objection to the location of the pool equipment and existing A/C unit as it will not adversely affect the existing drainage pattern. Accordingly, the Planning Department has no objection to Variances #1 and #2. The Owner is proposing to replace the existing garden shed with a new garden shed in the same location. The Planning Department also has no objection to the increased height for the new garden shed in the rear yard. The accessory structure will not physically or visually impact any abutting properties as it is partially shielded by existing vegetation (trees and shrubs) along the rear lot line. The accessory structure also complies with all other setback requirements of Zoning By-law 1-88. Accordingly, the Planning Department supports Variance #3. The Planning Department is of the opinion that the proposal is minor in nature, meets the intent of the Zoning By-law, and is desirable for the appropriate development of the land. Condition(s): None. Recommendation: The Planning Department supports Minor Variance Application A250/15. Report Prepared By: Natalie Wong, Planner 1 Christina Napoli, Senior Planner Development Planning Department I City of Vaughan I 2141 Major Mackenzie Drive I Vaughan, ON L6A 1T1 T: 905.832.8585 I F: 905.832.6080 I www.vaughan.ca DATE: August 18, 2015 TO: Todd Coles, Committee of Adjustment FROM: Steve Lysecki Development Engineering & Infrastructure Planning Services MEETING DATE: August 27, 2015 OWNER: FILE(S): CARYL ROSMAN A250/15 Location: Part of Lot 33, Concession 1 (Lot 15, Registered Plan 65M-2912) municipally known as 19 Windhaven Terrace, Thornhill. Proposal: 1. To permit a minimum interior side yard setback of 0.3 metres to pool equipment. 2. To permit a minimum interior side yard setback of 0.3 metres to an A/C unit. 3. To permit an accessory structure (garden shed) with a maximum height of 3.0 metres. By-Law Requirements: 1. A minimum interior side yard setback of 1.2 metres is required. 2. A minimum interior side yard setback of 1.2 metres is required. 3. A maximum height of 2.5 metres is permitted. Comments: The lot drains via split lot drainage; therefore, there is little impact from the proposed reduced setbacks for the pool equipment and the A/C unit. The A/C unit shall remain elevated. Accordingly, the Development Engineering and Infrastructure Planning Services Department does not object to Variance Application A250/15. Conditions: None. Date: August 10, 2015 Attention: Pravina Attwala RE: Request for Comments File No.: A250/15 Related Files: Applicant: Caryl Rosman Location: 19 Windhaven Terrace, Thornhill 1 COMMENTS: PowerStream has received and reviewed the proposed Variance Application. This review, however, does not imply any approval of the project or plan. All proposed billboards, signs, and other structures associated with the project or plan must maintain minimum clearances to the existing overhead or underground electrical distribution system as specified by the applicable standards, codes and acts referenced. In the event that construction commences, and the clearance between any component of the work/structure and the adjacent existing overhead and underground electrical distribution system violates the Occupational Health and Safety Act, the customer will be responsible for 100% of the costs associated with PowerStream making the work area safe. All construction work will be required to stop until the safe limits of approach can be established. In the event construction is completed, and the clearance between the constructed structure and the adjacent existing overhead and underground electrical distribution system violates the any of applicable standards, acts or codes referenced, the customer will be responsible for 100% of PowerStream’s cost for any relocation work. References: Ontario Electrical Safety Code, latest edition (Clearance of Conductors from Buildings) Ontario Health and Safety Act, latest edition (Construction Protection) Ontario Building Code, latest edition (Clearance to Buildings) PowerStream (Construction Standard 03-1, 03-4), attached Canadian Standards Association, latest edition (Basic Clearances) If more information is required, please contact either of the following: Mr. Barry N. Stephens Commercial & Industrial Services Supervisor Phone: 1-877-963-6900 ext. 4425 Fax: 905-532-4401 E-mail: [email protected] Mr. Tony D’Onofrio Supervisor, Subdivisions & New Services Phone: 1-877-963-6900 ext. 24419 Fax: 905-532-4401 E-mail: [email protected] 2 3 4