Geotechnical Survey Report
Transcription
Geotechnical Survey Report
Geotechnical Survey Report FGS Ref: Issue Date: 1234 February 2011 Client Name: Risk Address: Ms A another 23 Nowhere Rd Anywhere AB10 3AB Engineer: ### Company: Claim Ref: ### ### Directors: Trevor Ayres and Vivienne Ayres Geotechnical Services Manager: Office Manager: Geologist: CAD Technician: Martin Rush MSc FGS Louise Hiscock BSc (Hons) Carina Hicks BSc (Hons) Perry Martin AMCIHT Laboratory Manager: Lara Knight © FastrackTM 2011 Unit 9 Tyndales Farm Southend Road Woodham Mortimer Maldon Essex CM9 6TQ Tel: 0844 335 8908 Section: Fax: 0844 335 8907 FGS Ref: 1 #### Email: [email protected] Web: www.fastrack-geotechnical.co.uk GEOTECHNICAL SURVEY SUMMARY Property Address: Client Claim Ref: 1.1 #### Survey date: #### #### Operative: SE1 INTRODUCTION In accordance with your instructions, we visited the above site on 05th September 2010. The purpose of our visit was to provide information on the nature of the foundations and the underlying subsoil in order to identify the reason for the movement exhibited by the property. The geological survey map of the England and Wales (Sheet No. 295 - Taunton) shows the site to be underlain by the Mercia Mudstone Groups, noted to comprise of a predominately red, less commonly green-grey, mudstone and silt stones, with thick halite bearing units; with thin beds of gypsum and sandstones. The site is noted to be close to an area of unknown age terrace deposits. The site investigation comprised the excavation of 2No trial pits, one located on either corner of the rear projection. Through the base of each trial pit a hand auger borehole was drilled to a depth of approximately 1.50m where they were closed due to impenetrable strata. Details of the drainage survey are discussed within chapter 1.5 and recorded in full within Appendix 3. (Please refer to appendix 1 for site plan and location details). 1.2 FOUNDATION DETAILS The foundations of trial pit 1 comprise a CONCRETE footing, seated at a depth of 0.57m, noted to project 220mm from the face of the brick wall and attain a thickness of 200mm. The foundations of trial pit 1 were noted to be seated into loose, medium brown, claybound MADE GROUND containing whole bricks. The foundations of trial pit 2 comprise a CONCRETE footing, seated at a depth of 0.59m, noted to project 100mm from the face of the brick wall and attain a thickness of 220mm. The foundations of trial pit 2 were noted to be seated onto loose, red orange / brown, clay with grey mottling, containing black ash (MADE GROUND). (Please refer to appendix 2 for trial pit drawings and borehole logs). The control borehole (BH3) was noted to comprise topsoil over red-brown, topsoily, claybound MADE GROUND; the borehole was aborted at a depth of 0.80m due to an obstruction. No root activity was encountered within the boreholes. No water strikes were identified within either the trial pits or the boreholes, which were noted to be dry on completion. 1.3 DRAINAGE SURVEY A CCTV drainage survey was conducted on the accessible drainage of the property within close proximity to the area of damage, with 3No. manholes located and 3No. drainage runs surveyed Hydraulic tests were not possible due to the excessive invert of the manhole and the layout of the runs. (Please refer to appendix 3 for inspection log). 1.4 LABORATORY ANALYSIS All samples recovered were tested for their moisture content and atterberg limits. The comments and opinions expressed within this report are based on the ground conditions revealed by the site works, together with an assessment of the site and of the laboratory test results. Whilst opinions may be expressed relating to the subsoil conditions in parts of the site not investigated, for example between borehole or trial pit positions, these are for guidance and no liability can be accepted for their accuracy. For and on behalf of FASTRACK GEOTECHNICAL SERVICES © FastrackTM 2011 Unit 9 Tyndales Farm Southend Road Woodham Mortimer Maldon Essex CM9 6TQ Tel: 0844 3358908 Section: Fax: 0844 3358907 FGS Ref: 2 Email: [email protected] Web: www.fastrack-geotechnical.co.uk HEAVE CALCULATION REPORT Property Address: Client Claim Ref: Survey date: Operative: Heave Calculation th In accordance with your instructions we visited the above site on 15 October 2010 in order to examine the subsoil conditions, and we have used these findings to provide information on potential heave that might occur following tree removal in a desiccated soil profile. The site investigation comprised the drilling of 2No. hand auger boreholes to a maximum depth of 3.56m. Borehole 1 was drilled through the base of a trial pit excavated on the rear wall of the out building on site, whilst borehole 2, to act as a control, was drilled 7.50m from the front of the main building to the front of the property area, as far as possible from the effects of vegetation. Disturbed samples were taken at 0.50m intervals for the purpose of laboratory testing and insitu strength tests in the form of hand held shear strength / mackintosh probe tests were conducted at each sample level. The position of all boreholes can be found on the site plan within Appendix I, with full borehole logs within Appendix II. Selected samples were tested in accordance with BS1377, method of tests for soil for Civil Engineering purposes: 1990. Samples were tested for their full moisture content profile, with selected samples tested for the Atterberg limits. Selected samples were also sent to a UKAS accredited laboratory for filter paper method testing for soil suction. All laboratory results can be found within Appendix 3. Borehole 1 encountered a very stiff, dark orange/red, sandy, gravelly CLAY beneath the topsoil, at 0.20m depth, and present to the close of the borehole at 2.57m below ground level. Borehole 2, the control, encountered MADE GROUND to a depth of 0.70m, onto a grey brown, silty, sandy, gravelly CLAY present to a depth of 1.50m. A cream/grey, orange brown, silty CLAY with occasional gravel was then encountered, and present to the close of the borehole at 3.56m below ground level. Root activity was encountered within borehole 1 and samples of the roots from 0.04m, foundation level, 0.50m, 1.00m and 1.50m depths were sent to Richardson’s Botanical Identifications for the purpose of identification. The results of this show the roots to be of Acer spp., of Maples and Sycamores. Sample suction profiles can be used to estimate the amount of ground heave that may occur following tree removal in a desiccated soil profile. The heave prediction is normally based on the soil suction profile compared to a control borehole. However, when soil suctions are not available, a heave calculation can be calculated with the use of moisture contents only although this is not as accurate as that conducted using soil suction results. The calculated heave potential for borehole 1 is: BH Depth Heave potential BH1 0.50m 77mm BH1 1.00m 49mm BH1 1.50m 42mm BH1 2.00m 27mm BH1 2.50m 6mm Section 2 – Heave Calculation – Page 1 Unit 9 Tyndales Farm Southend Road Woodham Mortimer Maldon Essex CM9 6TQ Tel: 0844 3358908 Section: Fax: 0844 3358907 FGS Ref: 2 Email: [email protected] Web: www.fastrack-geotechnical.co.uk HEAVE CALCULATION REPORT Property Address: Client Claim Ref: Survey date: Operative: Atterberg limits tests were conducted on three samples of the CLAY subsoil from borehole 1, at 0.04m, 1.50m and 2.50m depths. This testing found the clay to be of intermediate plasticity (PI=18-20%) which indicates a low susceptibility to movement due to changes in moisture content. Full details of laboratory testing are shown within Appendix III. The comments and opinions expressed within this report are based on the conditions encountered and on the subsequent laboratory testing. Therefore, it is possible that some special conditions prevailing on site have not been taken into account. Carina Hicks For and on behalf of FASTRACK GEOTECHNICAL SERVICES Section 2 – Heave Calculation – Page 2 Unit 9 Tyndales Farm Southend Road Woodham Mortimer Maldon Essex CM9 6TQ Tel: 0844 335 8908 Appendix No: Fax: 0844 335 8907 FGS Ref: 1 #### Email: [email protected] Web: www.fastrack-geotechnical.co.uk LOCATION PLAN Property Address: Client Claim Ref: #### Survey date: #### Operative: #### SE1 © Crown Copyright. Licence no. 10001998 © NERC. All rights reserved N Scale Drawn by 1:20000@A4 MR © FastrackTM 2011 Unit 9 Tyndales Farm Southend Road Woodham Mortimer Maldon Essex CM9 6TQ Tel: 0844 335 8908 Appendix No: Fax: 0844 335 8907 FGS Ref: 1 #### Email: [email protected] Web: www.fastrack-geotechnical.co.uk GEOLOGY Property Address: Client Claim Ref: #### Survey date: #### Operative: #### N LC GD MG AL Scale Drawn by 1:20000@A4 MR © FastrackTM 2011 SE1 Unit 9 Tyndales Farm Southend Road Woodham Mortimer Maldon Essex CM9 6TQ Tel: 0844 335 8908 Appendix No: Fax: 0844 335 8907 FGS Ref: 1 #### Email: [email protected] Web: www.fastrack-geotechnical.co.uk GEOLOGY KEY Property Address: Client Claim Ref: #### Survey date: #### Operative: #### SE1 Superficial Geology Map Colour Map Code Rock Name Rock Type GD Glaciofluvial Deposits Sand and Gravel AL Alluvium Clay, Silt, Sand and Gravel MG Artificial Ground - Bedrock Geology Map Colour Map Code Rock Name Rock Type LC London Clay Clay, Silt and Sand Drawn by MR © FastrackTM 2011 Unit 9 Tyndales Farm Southend Road Woodham Mortimer Maldon Essex CM9 6TQ Tel: 0844 335 8908 Appendix No: Fax: 0844 335 8907 FGS Ref: 1 #### Email: [email protected] Web: www.fastrack-geotechnical.co.uk SITE PLAN Property Address: Client Claim Ref: #### Survey date: #### Operative: #### SE1 N CBH MH1 SVP FG1 TP1/BH1 TP2/BH2 RWP ©Crown Copyright. Licence no. 10001998 Key: Scale Drawn by Gullies and Pipes Trial Pit RWP SWG SVP FWG Shrubs and Trees Shrub Deciduous Manholes 1:200@A4 MR Borehole Conifer Appendix No: Telephone: 0844 3358908 Fax: 0844 3358907 Tyndales Farm, Southend Road, Woodham Mortimer, Email:[email protected] Maldon, Essex, CM9 6TQ Web: www.fastrack-geotechnical.co.uk FGS Ref: 2 #### TRIAL PIT 1 Property Address: #### Client Claim Ref: #### Survey date:#### Operative: SW1 Bay 0.00m 250 0.15m Concrete Claybound MADE GROUND containing brick 70 80 70 80 0.40m Concrete Light grey chalky CLAY 400 D1 @ F.L. (0.81m) V = 86-88kPa Founding strata: Light grey chalky CLAY Drawn by: Trial Pit Location: PM TP1/ BH1 Scale: 1:10 D= small disturbed sample, B= large bulk sample, U= undisturbed sample, MP= mackintosh proble blow counts, V= shear vane reading (kPa) © FastrackTM 2011 Tyndales Farm, Southend Road, Woodham Mortimer Maldon, Essex, CM9 6TQ Tel: 0844 3358908 Appendix No: 2 Fax: 0844 3358907 FGS Job No: #### # Email: [email protected] Web: www.fastrack-geotechnical.co.uk Property Address: Client Claim Ref: #### #### Survey date:#### Operative: Borehole ID: BH1 Hole Type: Scale: Samples Insitu Tests Water Strikes Type Depth (m) Type Results Depth (m) 1:35 Stratum Description and Observations Legend Dark brown, sandy, clayey MADE GROUND containing gravel and brick 0.40 D1 0.50 D2 1.00 D3 1.50 D4 2.00 D5 2.50 D6 3.00 D7 3.50 D8 4.00 D9 4.50 D10 5.00 D11 5.50 D12 6.00 V 112.00 108.00 Stiff, orange brown, silty CLAY containing small brick pieces 1 1.10 Firm / Firm to stiff, orange brown, silty CLAY V 76.00 72.00 2 V 102.00 98.00 3 V 140.00 4 grey mottling noted at 4.00m depth water pockets noted at 4.50m depth V 140.00 V 140.00 5 6.00 6 End of Borehole at 6.00 m Key: Water Strike D Disturbed Sample V Insitu vane test MP Mackintosh Probe Test Remarks: Borehole closed at 6.00m depth Noted to contain 0.25m of standing water in base of borehole on completion N.b. Unless otherwise stated small vane paddle used © FastrackTM 2011 Appendix No: Telephone: 0844 3358908 Fax: 0844 3358907 Tyndales Farm, Southend Road, Woodham Mortimer, Email:[email protected] Maldon, Essex, CM9 6TQ Web: www.fastrack-geotechnical.co.uk FGS Ref: 2 #### TRIAL PIT 2 Property Address: #### Client Claim Ref: #### Survey date:#### Operative: SW1 Conservatory 0.00m Concrete 0.10m Claybound MADE GROUND containing brick 330 150 0.40m Light grey chalky CLAY Concrete 350 0.68m Very dense orange gravelly SAND D1 @ F.L. (0.68m) MP = 4-5-100/ 45mm Travel Founding strata: Very dense orange gravelly SAND Drawn by: Trial Pit Location: PM Scale: 1:10 D= small disturbed sample, B= large bulk sample, U= undisturbed sample, MP= mackintosh proble blow counts, V= shear vane reading (kPa) TP2/ BH2 © FastrackTM 2011 Tyndales Farm, Southend Road, Woodham Mortimer Maldon, Essex, CM9 6TQ Tel: 0844 3358908 Appendix No: 2 Fax: 0844 3358907 FGS Job No: #### Email: [email protected] Web: www.fastrack-geotechnical.co.uk Property Address: Client Claim Ref: #### #### Survey date:#### Operative: Borehole ID: BH2 Hole Type: Scale: Samples Insitu Tests Water Strikes Type Depth (m) Type Results Depth (m) Stratum Description and Observations Legend Block paving 0.08 0.10 0.20 0.25 D1 1:35 Sand Lean mix concrete 0.50 Hardcore sub base Firm, grey brown, mottled orange, silty CLAY D2 1.00 D3 1.50 D4 2.00 D5 2.50 D6 3.00 D7 3.50 D8 4.00 D9 4.50 D10 5.00 D11 5.50 D12 6.00 V 64.00 68.00 1 V 140.00 2 V 140.00 3 V 140.00 4 V 140.00 5 V 140.00 6.00 6 End of Borehole at 6.00 m Key: Water Strike D Disturbed Sample V Insitu vane test MP Mackintosh Probe Test Remarks: Borehole closed at 6.00m depth Noted to be dry on completion N.b. Unless otherwise stated small vane paddle used © FastrackTM 2011 Tel: 0844 3358908 Appendix No: Fax: 0844 3358907 FGS Ref: 3 ### Email: [email protected] Tyndales Farm, Southend Road, Woodham Mortimer, Maldon, Essex, CM9 6TQ Web: www.fastrack-geotechnical.co.uk LABORATORY RESULTS Property Address: ### Client Claim Ref: ### Client: SAMPLE DETAILS ### ANALYSIS REQUESTED Investigation date: 23rd November 2010 Moisture Content PSD Sample details: Bags as received Liquid Limit Soil Suction Samples received: 26th November 2010 Plastic Limit Shear Strength Schedule recieved: 26th November 2010 Plasticity Index Contamination Samples tested: 26th Nov - 8th Dec 2010 Root ID Root/Tree DNA Results reported: 8th December 2010 Other (please state) TEST DETAILS General Sample descriptions were written in accordance with BS 5930:1999. Samples were prepared in accordance with BS 1377: Part 1: 1990, section 7 Samples from this contract will be retained for 1 calender month following the issue of this report unless otherwise notified Written approval is required from Fastrack Geoetchnical Services Limited to reproduce report in full. The results shown within this report only relate to the samples tested Moisture Content Samples were tested in accordance with BS 1377: Part 2: 1990, section 3.2 (Oven drying method) In accordance with Note 1 to paragraph 3.2.4 of BS 1377 Part 2 1990; these moisture contents have been corrected to give the equivalent moisture content of the fraction passing the 425µm sieve, to enable comparison with the liquid & plastic limits. (If condition of test is 'natural' the retained percentage is an estimated value, if condition is 'washed' the percentage is a measured value). o Samples are dried at 105-110 C unless otherwise stated. Atterberg Limits Samples were tested in accordance with BS 1377: Part 2: 1990, section 4.3 (4 drop LL), 4.4 (1 drop LL), 5.3 (PL) and 5.4 (PI) Test results on samples with a sand content, may show less accurate results. If condition of test is 'washed' results relate to the fraction passing the 425µm sieve only. * Driscoll's rules deem the soil to be desicated where the moisture content is less than the value calculated using driscoll's rule 1 and/or 2 Particle Size Distribution Samples were tested in accordance with BS 1377: Part 2: 1990 section 9.2 (Wet sieving method) Undrained Shear Stength Samples were prepared in accordance with BS 1377: Part 7: 1990 section 8.3 and testing in accordance with BS 1377: Part 7: 1990: section 8.4 (undrained shear strength in triaxial compression without measurement of pore pressure (UU)) Soil Suction Samples were prepared and tested based on the BRE digest No:IP4/93 (Corrected). (Corrected) 'A method of determining the state of desiccation in clay soils.' (Filter paper method). Test results on samples with a sand or silt content, may show less accurate results. Deviation to standard procedure - Polythene bags are not used from weighing filter papers. Page 1 of 3 © FastrackTM 2011 Tel: 0844 3358908 Appendix No: Fax: 0844 3358907 FGS Ref: 3 ### Email: [email protected] Tyndales Farm, Southend Road, Woodham Mortimer, Web: www.fastrack-geotechnical.co.uk Maldon, Essex, CM9 6TQ LABORATORY RESULTS Property Address: ### Client Claim Ref: ### Depth MC LL PL PI Class % Retained (425µm) BOREHOLE 1 Corr. MC Soil Suction Condition of test Soil Description (m) (%) (%) (%) (%) (%) 0.81 24.5 24.75 35 40 42 CL 1 (kPa) 130 Natural 1.00 22 23.16 32 41 45 CL 5 122 Natural Grey / brown silty CLAY containing claystone and chalk fragments Grey silty clayey MADEGROUND containing brick, claystone and chalk fragments 1 50 1.50 24 25.26 25 26 33 42 43 CL 5 132 Natural Grey / brown silty CLAY containing claystone and chalk fragments 2.00 25.5 26.84 34 43 41 CL 5 140 Natural Brown silty CLAY containing claystone and chalk fragments GRAPH Corrected Moisture Content (%) Liquid Limit (%) Plastic Limit (%) LL x 0.4 (Driscoll's Rule 1) A-Line 0.81m PL + 2% (Driscoll's Rule 2) Soil Suction (kPa) 1.50m 2.00m 10 Moisture Content (%) 20 30 40 50 80 0.00 0 1.00m Upper Plasticity Range Int.med High V. High CI CH CV CE MI MH MV ME Extr. High 70 Low Plasticity 60 0.50 CL y Index (%) Plasticity 40 50 130 Depth h (m) 1.00 122 20 30 1.50 132 10 2.00 140 0 2.50 ML 120 125 130 135 Soil Suction (kPa) 140 145 0 20 40 60 Liquid Limit (%) 80 100 Comments: Issued by: Lara Knight (Laboratory Manager) Other Signed: Page 2 of 3 © FastrackTM 2011 120 Tel: 0844 3358908 Appendix No: Fax: 0844 3358907 FGS Ref: 3 ### Email: [email protected] Tyndales Farm, Southend Road, Woodham Mortimer, Web: www.fastrack-geotechnical.co.uk Maldon, Essex, CM9 6TQ LABORATORY RESULTS Property Address: ### Client Claim Ref: ### Depth MC LL PL PI Class % Retained (425µm) BOREHOLE 2 Corr. MC Soil Suction Condition of test Soil Description (m) (%) (%) (%) (%) (%) 0.68 15.6 15.76 25 32 40 CL 1 (kPa) 125 Natural Brown clayey SAND containing gravel 1.00 16.2 16.7 23 35 41 CL 3 126 Natural Brown clayey SAND containing gravel 1 50 1.50 17.5 17 5 18.42 18 42 28 37 42 CL 5 140 Natural Brown clayey SAND containing gravel GRAPH Corrected Moisture Content (%) Liquid Limit (%) Plastic Limit (%) LL x 0.4 (Driscoll's Rule 1) PL + 2% (Driscoll's Rule 2) Soil Suction (kPa) 10 Moisture Content (%) 20 30 0.68m 1.00m 1.50m 40 80 0.00 0 A-Line Upper Plasticity Range Int.med High V. High CI CH CV CE MI MH MV ME Extr. High 70 0.20 Low Plasticity y Index (%) Plasticity 40 50 Depth h (m) 0.80 0.60 60 0.40 CL 125 10 1.40 20 1.20 30 1.00 126 140 0 1.60 ML 120 125 130 135 Soil Suction (kPa) 140 145 0 20 40 60 Liquid Limit (%) 80 100 Comments: Issued by: Lara Knight (Laboratory Manager) Other Signed: Page 3 of 3 © FastrackTM 2011 120 Richardson's Botanical Identifications 49-51 Whiteknights Road, Reading, RG6 7BB | [email protected] | 0118 986 9552 . Fastrack Geotechnical Services Ltd. Tyndales Farm Southend Road Woodham Mortimer MALDON, Essex CM9 6TQ Order No Date Job Ref Dear Sirs Risk Address The samples you sent in relation to the above on Date (received by us on Date) have been examined. The structure was referable as follows: BH1, 1.50m 1 root: microscopic examination showed insufficient cells for recognition. BH1, 3.00m 1 root: most like QUERCUS (Oak) or the related CASTANEA (Sweet Chestnut). This was a very THIN and decayed sample. A further root, not examined in detail appeared similar under low magnification. 17 pieces of TWIGS, not roots. Not identified. 21 roots: unfortunately insufficient cells for identification. BH2, 2.50m 1 root: QUERCUS (Oak). 2 further roots, not examined in detail appeared similar under low magnification. 5 pieces of TWIGS, not roots. Not identified. 3 roots: unfortunately insufficient cells for identification. BH2, 3.00m 1 root: QUERCUS (Oak). 8 further roots, not examined in detail appeared similar under low magnification. 11 roots: unfortunately insufficient cells for identification. I trust this is of help; please call us if you have any queries. Yours faithfully Dr Ian B K Richardson * * Try out our web site on www.botanical.net * * ____________________________ Identified with no information on vegetation, on or off site. © FastrackTM 2011 Tel: 0844 3358908 Appendix No: Fax: 0844 3358907 FGS Ref: 4 #### Email: [email protected] Tyndales Farm, Southend Road, Woodham Mortimer, Maldon, Essex, CM9 6TQ Web: www.fastrack-geotechnical.co.uk DRAINAGE SURVEY Property Address: #### Client Claim Ref: #### Survey date: #### Operative: SW1 Following your recent instruction we attended the above property and carried out a cctv camera survey and hydraulic testing of the drainage, in accordance with procedures detailed in the WRc Drain Repair Book. Manhole / Inspection chamber Summary: Node Invert Level (m) Manhole Construction Pipe Size Pipe Material Manhole Condition MH1 0.90m Brick & Render 100mm Salt Glaze GOOD Type of Cover Size of Cover Cast Iron 660x510mm Hydraulic Testing Summary: Run From To 1 MH1 2 MH1 Result Remarks Upstream PASS No loss Downstream FAIL 2cm drop over 5 minutes 3 4 5 6 Serviceability: 1 Is the system failing to discharge normal household flows to the sewer system? (i.e. recurrance of blockage) No 2 Is there evidence of leakage occuring (infiltration or exfiltration)? No 3 Is there intermittent storm-water flooding? No 4 Has a hydraulic leakage test failed? N/A 5 Do observed defects make the drain unservicable? No Comments: Recommendations for Repair: Run Grade Recommended action 1 A None required 2 B Install structural liner 3 C Replace with new uPVC 4 5 6 © FastrackTM 2011 Tel: 0844 3358908 Tyndales Farm, Southend Road, Woodham Mortimer, Maldon, Essex, CM9 6TQ 4 Appendix No: Fax: 0844 3358907 #### FGS Ref: Email: [email protected] Web: www.fastrack-geotechnical.co.uk DRAINAGE SURVEY Property Address: #### Client Claim Ref: #### Run Details: (Please refer to appendix 1 for site plan and run layout) Ownership Run From To Pipe Diameter Pipe Materials Duty Direction 1 MH1 Upstream 100mm Salt Glaze Foul Upstream Private 2 MH2 Downstream 100mm Salt Glaze Foul Downstream Private 3 4 5 6 Grade Guidelines: Grade A Grade B Grade C Condition grade A: Structurally sound with no leakage evident. Slight crack/defects permitted. Condition grade B: Cracks and/or fractures observed but pipe provides sufficient arching support. Some leakage may be evident. Condition grade C:Structurally unsound with insufficient arching support. Total collapse/blockage likely in the future. Inspection Report: Observations Remarks m 1 0.00 SS Start Survey 0.50 WL Water level 1.00 CN Connection 1.00 WL Water level 0 5.50 CN Connection 0 Lateral enters from above (FG2) 10.00 SF 0.00 SS 8.00 CC B Crack, circumferential 5 Standing water 8.50 JD(M) B Joint displaced medium 50 Standing water 9.00 WL Water level 0 Standing water 10.00 SF 0.00 SS 1.50 CL B Crack, longitudinal 3.20 OJ(L) C Open joint large SF C Finish Survey 2 3 Code Grade Water (%) Clock Run A 5 Standing water Lateral enters from above (FG1/SVP) Finish Survey Start Survey B Finish Survey Start Survey © FastrackTM 2011 Tyndales Farm Southend Road Woodham Mortimer Maldon Essex CM9 6TQ Tel: 08443358908 Fax: 08443358907 Email: [email protected] Web: www.fastrack-geotechnical.co.uk DRAINAGE REPAIR ESTIMATE Property Address: Client Claim Ref: #### Survey date: #### Operative: #### Date Our Ref: Your Ref: Re: #### ######## Estimate for drainage repairs Works: 1. RWG and KWG Excavate and replace Gully and 1m pipework with new uPVC, jet runs and CCTV survey TOTAL £##.## exc vat This estimate is exclusive of vat, is based on our interpretation of the required repairs and limited to the items listed above; should any further works be deemed necessary they will be charged in accordance with the schedule of rates. Should you require alternative repairs to be carried out, please provide details and we will issue a revised quotation as soon as possible. An assumption has been made that a building notice is not required for the completion of these works; in the event that a building notice is required, we can obtain it on your behalf; this will be charged at cost plus 10%. This estimate should be read in conjunction with our standard schedule of assumptions and conditions of contract; a copy of which can be obtained from the office. This estimate is valid for 2 calendar months from the date of issue. Should you have any queries please do not hesitate to contact the office on 08443358908. Yours sincerely Fastrack™ Geotechnical Services Ltd © FastrackTM 2011 SE2