64 channels/48kHz/24bit/1.33ms

Transcription

64 channels/48kHz/24bit/1.33ms
64 channels/48kHz/24bit/1.33ms
- SYSTEM DATA
- CONTENTS
Ethernet based multichannel audio system for public address, music
emergency and broadcast applications
Simultaneous transmission of up to 64 digital audio channels in studio quality
(48 kHz / 24 bit), with a constant latency period of 1.33 ms (digital)
EN 54-16
Real-time configuration with ITEC NET NET DESIGN: Allows system configuration changes during normal operation
of the system
page 4
Spider44
page 6
Spider04
page 7
SpiderLine16
page 8
SpiderMike2
page 9
Fire fighters callstation
page 10
Switch 4/1
page 11
04
B
A
DC
24V
DC 24V
POWER IN
POWER
IN
10V RX TX
T
T
TX- TX+ RX- RX+
1
2
3
4
5
6
7
T
8
LINE OUT
T
-
T
+
-
MIC IN
AMP 1
T
+
-
+
-
T
+
2
3
4
5
SPEAKER LINE MONITORING
6
7
8
9
10
11 12
100V AMP IN
AMP 3
-
T
AMP 1
+
Up to 16,000 output zones in one audio network
Can also be used with standard Ethernet network components
Integrated 2 GB memory card for alarm texts and music files
Recording Capacity 256 files, total time about 3 hours!
-
RET.
+
-
+ IN -
+
-
ZONE 2
OUT
+
-
RET.
+
-
+ IN -
+
-
ZONE 3
OUT
+
-
RET.
+
-
ZONE 4
OUT
IN
+
-
+
-
RET.
+
Made in Austria
L R
1
-
+
-
+
+
-
+
-
+
3
5
-
+ -
+
-
+
-
+
7
-
+
-
+
9
-
+
-
+
11
-
+
13
14
-
+
13
-
+
15
16
-
+
15
-
+
-
-
+
DC
24V
DC 24V
POWER IN
POWER
IN
RS485
TX- TX+ RX- RX+
HAV.
LINE IN
AMP 2
Channel A
24V DC
Speaker impedance and line monitoring during program mode
ITEC NET DESIGN configuration software
+
SD CARD
AMP 2
230V AC
Integrated real-time recorder for delayed announcements
System components certified according to EN 54-16
ZONE 1
OUT
SPEAKER LINES
AMP 3
+
HAV.
2
4
6
8
10
12
14
-
16
Made in Austria
Up to 4000 devices can work simultaneously together in a network
It has never been so easy to plan complex audio systems
-
SPIDERLINE 16
1
Real-time audio transmission:
Constant latency of 4.6 ms analog-in/analog-out
ITEC NET application interface (TCP / IP) for connecting
to security management systems
+ IN -
+
10V
04
T
Distributed audio system no „single point of failure“
System overview
EN 54-4
DigiPower
page 12
Software NET DESIGN
page 13
API interface
UP-RemoteControl Panel
page 14
DSV54-4 power supply
page 18
Certified voice alarm speaker systems
page 19
EN 54-24
Fault
Operating mode
Channel A
Fault
24V DC
Operating mode
Fault
Operating mode
Channel B
Clip
Signal
Channel C
Operating mode
POWER 2x250T
DIGI
POWER 4x150T
Clip
Signal
Fault
Operating mode
Clip
Signal
230V AC
Fault
DIGI
Channel B
Clip
Signal
Channel D
Clip
Signal
Fault
Operating mode
Clip
Signal
-
- SYSTEM OVERVIEW
NET DESIGN
For configuration,
monitoring, logging
and recording
Media Control
Integrated 2 GByte micro SD Flash
Card
SPIDERMIKE2
4x analog
Audio in
SPIDER44
RS232
4x analog
Audio out
Panel PC
API-Software
SPIDER44
Dynamic or electret
Microphone monitoring
SPIDERMIKE2
RS 232
8x dig. Output
Built-In
Speaker
ITEC
NET SWITCH
04
SPIDER04
8x 0-10V Input
SPIDER44
8x dig. Output
EOL
RS 485
8x dig. Output
EOL
SPIDER44
EOL
EOL
SPIDERLINE 16
1
2
3
4
5
SPEAKER LINE MONITORING
6
7
8
9
10
11 12
13
14
15
SPIDERLINE16
16
EOL
or
EOL
EOL
EOL
EOL
EOL
EOL
EOL
EOL
4x Speakerline monitoring
EOL
EOL
4x Speakerline monitoring
EOL
EOL
EOL
EOL
up to more than 4.000 nodes in one network
EOL
EOL
EOL
EOL
EOL
- HARDWARE COMPONENTS
SPIDER44
SPIDER04
The combined Break-in/Break-out module in 19“ design, equipped with 4 analog audio inputs and outputs,
2 network ports and 24 VDC power supply.
Other connection options: 2 serial ports (RS-232 and RS-485) for control tasks, 8 analog inputs, 8 digital
inputs, 8 digital outputs, optional plug-in card for speaker monitoring (4 channels), integrated 2 GB Micro SD
Card Flash memory card as a voice mail. Front-page display for the output of messages, program selection
and volume. The digital encoder / push-button can also be used to operate the SPIDER44 directly when
configured accordingly. Furthermore, located at the front an infrared receiving diode is in place allowing an
access via IR remote control (e.g.: Program and volume).
Online/realtime system-configuration with free ITEC PC-software NET DESIGN from every network accesspoint. Multiple access, realtime configuration of all system parameters including audion-functionalities!
The only Break-out module in 19“ design, equipped with 4 analog audio outputs, 2 network ports and 24
VDC power supply. Other connection options: 2 serial ports (RS-232 and RS-485) for control tasks, 8 analog
inputs, 8 digital inputs, 8 digital outputs, optional plug-in card for speaker monitoring (4 channels), integrated
2 GB Micro SD Card Flash memory card as a voice mail. Front-page display for the output of messages and
error states.
Online/realtime system-configuration with free ITEC PC-software NET DESIGN from every network accesspoint. Multiple access, realtime configuration of all system parameters including audion-functionalities!
Speaker- &
Speakerline-Monitoring
Technical data:
General:
up to 64 digital audio channels (default)
IEEE802.3 Ethernet - based network with 100Mbit/s duplex
4 analog audio inputs and 4 analog outputs (XLR / M / F)
lowest latency times due to high-performance DSPs
Power supply: 24 VDC
Power consumption: 15 VA
LINE DETECTION MODUL
Technical data:
General:
Interfaces / IOs:
8 analog inputs
8 digital control inputs, 8 digital control outputs
1x RS232, 1x RS485
2x Ethernet RJ45 connector
Infrared Remote Control
up to 64 digital audio channels (default)
IEEE802.3 Ethernet - based network with 100Mbit/s duplex
2 LAN-ports on RJ45 for redundant networks
4 analog outputs (auf XLR/M)
Operating temp.: –5°C / +40°C
Power supply: 24 VDC
Power consumption: 15 VA
(fig.1)
Audio Features:
16/24 or 32-bit Digital Audio
Sample rate: 48 or 96 kHz
Adjustable latency: 0.6 / 1.3 / 2.6 ms
Dynamic range: 103 dB
Total harmonic distortion (THD) <0.005 %
Frequency response: 20 Hz - 20 kHz (± 0.5 dB)
Interfaces / IOs:
END OF LINE MODUL
8 analog inputs 0 - 10V
8 digital control inputs, 8 digital control outputs
1x RS232, 1x RS485
2x Ethernet RJ45 connector
(fig.2)
Audio Features:
16/24 or 32-bit Digital Audio
Sample Rate: 48 oder 96kHz
Adjustable latency: 0.6 / 1.3 / 2.6 ms
Dynamic range: 103 dB
Total harmonic distortion (THD) <0.005 %
Frequency response: 20 Hz - 20 kHz (± 0.5 dB)
44
A
B
T
10V RX TX
1
2
3
4
5
6
7
8
T
T
TX- TX+ RX- RX+
+ IN -
+
-
ZONE 1
OUT
+
-
RET.
+
-
+ IN -
+
-
ZONE 2
OUT
+
10V
-
RET.
+
-
+ IN -
+
-
ZONE 3
OUT
+
-
RET.
+
-
ZONE 4
OUT
IN
+
-
+
-
RET.
+
DC
24V
DC 24V
POWER IN
POWER
IN
-
TX- TX+ RX- RX+
44
Made in Austria
A
44
T
DC
24V
DC 24V
POWER IN
POWER
IN
10V RX TX
T
B
1
2
3
4
5
6
7
8
T
AES/EBU
04
+ IN -
+
-
ZONE 1
OUT
+
-
RET.
+
-
+ IN -
+
-
ZONE 2
OUT
+
10V
04
Made in Austria
-
RET.
+
-
+ IN -
+
-
ZONE 3
OUT
+
-
RET.
+
-
ZONE 4
OUT
IN
+
-
+
-
RET.
+
-
- HARDWARE COMPONENTS
SPIDERLINE16
SPIDERMIKE2
The complete Voice Evacuation Central System! Central system? Isn´t ITEC NET a decentalized system?
Yes it is, but the new ITEC NET SPIDERLINE16 is all in one: A central system for small and simple installations
and a fully integrated network-componentent in any ITEC NET-system combination:
Line multiplexer, 4 x 16 matrix switcher, backup amplifier manager, digital storage for audio files, line- and
speaker monitoring system, stand alone and/or network component.
The affordable solution for small and mid-size only EVAC-installations and complementing HQ-ITEC NET
realtime event sound systems for e.g. stadiums and conference centers.
The call station, remote control and monitoring system - all in one.
ITEC Spidermike2 is equipped with the same characteristics as the
Spider44, however the functions are distributed in a different way. The
communication terminal offers 19 soft keys (that can be labeled with insertion stripes individually), a double spaced message monitor for the
display of help and error messages, a XLR connection for microphones
(dynamic or electret), a built-in speaker for microphone monitoring, intercom, respectively alerting integrated 2 GByte micro SD Flash Card.
Rear panel connectors: 2 x RJ45 network port, Power supply: 24 VDC.
Optional Keyboard Extensions à 24 keys. Expandable to 115 keys.
Technical data:
Inputs:
Technical data:
Power supply: 24 VDC
redundant LAN-ports: 2 x RJ 45
4x100Volt amplifier inputs to connect certified power amps, integrated pilot tone amp.
8 digital control inputs
8 analog inputs (0-10V)
RS 485
2 audio-inputs (Mic/Line)
Micro SD-card-slot
General:
Ethernet-based network with 100 Mbit /s duplex (CAT5 cable or fiber optic)
2 analog microphones / line inputs
Integrated speaker
1 additional analog audio output
2-line text display for status and error messages
19 free configurable soft keys
2 digital outputs
6 analog measurement inputs
SpiderMike2
Integrated 2 GByte micro SD Flash Card
Base station
Power supply: 24 VDC
Outputs:
4 x NF-Out
16 x LS-Out (2 x 8 for A/B or 1 x 16)
8 digital outputs
Fault relais contacts
Audio Features:
16/24 or 32-bit Digital Audio
Sample rate: 48 or 96 kHz
Adjustable latency: 0.6 / 1.3 / 2.6 ms
Dynamic range: 103 dB
Total harmonic distortion (THD) <0.005 %
Frequency response: 20 Hz - 20 kHz (± 0.5 dB)
END OF LINE MODUL
Audio Features:
SPIDERLINE 16
1
LINE OUT
3
4
5
SPEAKER LINE MONITORING
6
7
8
9
10
11 12
100V AMP IN
AMP 3
+
-
MIC IN
T
T
-
+
-
T
AMP 1
+
2
AMP 1
+
-
+
13
14
15
16
SPEAKER LINES
AMP 3
-
1
+
-
3
+ -
5
+
-
7
+
-
9
+
-
11
+
-
13
-
+
15
-
+
DC
24V
DC 24V
POWER IN
POWER
IN
RS485
TX- TX+ RX- RX+
SD CARD
+
HAV.
T
T
-
AMP 2
L R
T
+
LINE IN
+
-
AMP 2
+
-
HAV.
+
2
+
4
+
6
+
8
+
10
-
Automatic microphone
monitoring and logging
(Audio In 1)
+
12
+
14
-
+
-
16
Made in Austria
16/24 or 32-bit Digital Audio
Sample rate: 48 or 96 kHz
Adjustable latency: 0.6 / 1.3 / 2.6 ms
Dynamic range: 103 dB
Total harmonic distortion (THD) <0.005 %
Frequency response: 20 Hz - 20 kHz
(± 0.5 dB)
Built-In speaker (Audio Out 1)
Keyboard Extensions
(Up to 4x 24 keys)
- HARDWARE COMPONENTS
FIRE FIGHTERS CALL STATION (ÖNORM F 3033)
The fire fighters call station has within all security relevant PA applications always the highest priority. With this
call station the responsible fire fighters chief is able to activate, start or interrupt on the flash card pre-stored alarm
and evacuation messages across zones. When removing the microphone from its holder, text announcements
are interrupted and live announcements can be spoken in by pushing a further talk button at the microphone.
All functions of the call station are continuously monitored to ensure an operation at all times: For example, the
function of the microphone cartridge, the contents of the memory chips and the microprocessors.
The call station is networked redundant to the ITEC NET switches, and what the 24 V DC power supply concerns
connected to the ITEC NET backup power supply.
Different national and international standards are governing the functions and features of call station for fire
brigades. The terminal shown here corresponds to the Austrian standard F3033 (for system designs according to
TRVB S 158).
NETWORK-SWITCH
ITEC NET is based on the Ethernet standard IEEE 802.3, layer 2, 100 Mbit/s duplex in principle. That means
for setting up a network you can use all the standard components of the computer world for networking
ITEC NET devices without hesitation. However, the switches are system relevant components and need to be
certified for the implementation in security sound systems according to EN 54-16. As leading manufacturers of
network switches have no devices in their program to date, which are certified according to this particular fire
alarm standard, we have developed a switch on our own and precisely tailored it to the ITEC NET requirements.
Among others, these are facilities with fiber optic connections for long distance transmissions and single-source
24V DC power supplies (for a connection to certified power supply devices).
Technical data:
General:
Meets IEEE802.3u standard
Provides 2x 4x 10/100 Mbps Fast Ethernet ports and 1 x 100 Base-FX port
Global LED support (e.g.: power status, 100Lnk/Act, Full duplex per port)
IEEE 802.1q tag-based VLAN
VLAN ID tag / un-tag options per port
QoS priority management per port
Automatic MDI / MDI-X crossover
Stand alone (opt. managed functionality)
DC IN Power: 24 V / max. 1 A
Technical data:
General:
Ethernet-based network with 100 Mbit /s duplex (CAT5 cable or fiber optic)
Hand held microphone
Integrated speaker
Audio Features:
1 additional analog audio output
16/24 or 32-bit Digital Audio
6 announcement buttons
Sample rate: 48 or 96 kHz
Status indication lights
Adjustable latency: 0.6 / 1.3 / 2.6 ms
2 digital outputs
Dynamic range: 103 dB
6 analog measurement inputs
Total harmonic distortion (THD) <0.005 %
Integrated 2 GByte micro SD Flash Card
Frequency response: 20 Hz - 20 kHz (± 0.5 dB)
Power supply: 24 VDC
Fiber port:
Supports multi-mode fiber and SC connectors
802.3u 100 BaseFX compliant
Fixed 100 Mbps Full duplex operation
- SOFTWARE
NET DESIGN
- HARDWARE COMPONENTS
DIGIPOWER POWER AMPLIFIER
ITEC NET DESIGN is a Windows-based application for configuring and monitoring the entire ITEC NET network. Included is a TCP/IP interface (ITEC NET API) allowing a direct link to other control systems, such as
media control or security management systems. In addition NET DESIGN offers the possibility to update the
DSP- and control software from any point of the network. The huge number of monitoring and logging capabilities
ensures a safe operation within this large audio and data distribution system.
System Overview
In this window you will find all
ITEC NET components plus the
connected configuration PCs.
Photos or sketches of the system
floor plan can be used as background information with a free
arrangement of all components.
The „jump to „ function quickly
finds all devices with direct access
to the configuration pages.
Full power even at 24 V DC single supply! An absolute must for system designs conforming to international
standards. Power supply equipment according to EN 54-4 provides after a breakdown replacement power
directly from the connected accumulator (24 V DC). Therefore power amplifiers must be capable to provide even
at 24 V DC the full output power. The new ITEC DigiPower series not only meets this requirement, but offers also
many other important features such as an “energy-optimized „stand-by” mode.
2 models: 2x250 W/100 V and 4x150 W/100 V
Control LEDs for all signal and operation states
Fault signals for battery and mains
Fault signal for the power amplifier
2/4 channel in a 2 HU 19“ rack
Low installation depth (only 260 mm)
All connections plug-in/screw terminals
Balanced inputs with transformer option
Automatic stand-by mode
Protection for open-circuit, shorts, over temperature, DC
230 V AC and DC 24 V power supply
Start-up delay
Maintenance-free cooling system without fans
Digital signal processing
Only 10 W power consumption in stand-by mode
Channel A
Fault
24V DC
Operating mode
Channel B
Clip
Signal
Fault
Operating mode
DIGI
Clip
Signal
230V AC
Channel C
Fault
Operating mode
Channel D
Clip
Signal
Fault
Operating mode
System Tree Audio
Input Config
Clip
Signal
POWER 4x150T
Each audio input has the following
settings:
Mic / Line
Gain in dB steps
Compressor / Limiter
Various level controls
Network channel assignment
- SOFTWARE
NET DESIGN
A particular highlight is the exceptional possibility of real-time configuration:
The technician can configure “ITEC NET Systems” in real-time during operation without the need for a system
re-boot afterwards. The software runs on Windows XP / Server 2003 / Windows 7 / Server 2008
System List
Feeding Channels
Displays the current state of all audio channels in
the network.Offers the possibility of recording simultaneously up to 8 network channels on a PC.
System Tree Audio Output Config
Each audio output has the
following settings:
Modes (for example: Normal
Operation)
4-channel mixer (mixing up to 4
network channels on one output
channel)
Output level control selection
System Tree Keypad
Config Table
Different functions can be
assigned to each soft key, e.g.:
Zone selection
Talk key
All Zones
Chime
Delete
Alarm texts
+ / -, up / down, etc.
System Tree Audio
Output Priority Table
Independent of the program
channels the priority channels
are defined here: 16 different
priority levels are adjustable
System Tree
Output EQs, Delay
For each audio output
the following DSP functions
are available:
4x fully parametric EQ and/or
4x high-pass filter
4x low-pass filter
4x high shelf
4x low shelf
1x delay up to 650ms
System Tree
Zone Select Table
With an entry in this table individual outputs or groups of outputs are explicitly addressed via
priority announcement channels. This allows the direct access of a call station to specific
output zones (The prioritization
of terminals among each other
had been defined in the output
priority table in advance).
- API SOFTWARE
APPLICATION PROGRAMMING INTERFACE
This TCP/IP based software interface for ITEC NET
offers all necessary functions to operate and monitor a
system. Using the free available software “ITEC tablet
designer” an application has been implemented. This
program allows you easily to manage complex PA systems via an amateur safe and self-explanatory graphical
user interface. The user interface can be arranged freely
and is highly flexible due to its modular design. Another
request to the interface, that had been implemented,
was the connection of “ITEC NET” to higher-level security management systems to combine all security relevant disciplines in a large building (fire alarm systems,
access systems, video surveillance, etc.).
- UP REMOTE
CONTROL PANEL
Wall-mount control panel, featuring program selection,
output volume control, preset recall funktions. RS 485
communication protocol supports up to 16 panels. Supporting and powered by ITEC NET- and all ITEC
Mixer- and Splitter series.
BACKUP POWER SUPPLY
Backup power supply for system designs according to EN 833-4 and TRVB S 158
The digital power supply ITEC DSV54-4 is certified according to EN 54-4:1997 + A2: 2006. It is used to
supply the components of the individual modules and for charging / monitoring of the emergency batteries.
The power supply is intended for a connection to a 230 V/50 Hz (±15 %) power network and has to be
connected via a two-pole pre-fuse of maximum 16 A. The integrated power supply provides power up to
300 W at 24 V DC. Thus during mains operation, in addition to the load current that is needed to recharge the
batteries within 24 hours on at least 80 % of its rated capacity, sufficient power for the supply of 24 V system
components (Spider44, SpiderMike2, Switch4 /1) is available (e.g.: 6 A for charging batteries with 160 Ah total
capacity and 6 A for other devices). Supply voltage, connected batteries and the pre-fuses of the low-voltage
outlets are monitored by the ITEC DSV54-4. Errors are reported via LEDs on the front side and via potential-free
relay changeover contacts. The internal resistance of the batteries is also measured cyclical. In case the resistance
gets greater than 20 mΩ, it is reported at the front side via LEDs and relay contacts. The device is equipped with a
deep discharge protection, which is activated when the battery voltage drops below 1.8 V/cell and which ensures
a reliable protection of the batteries.
- VOICE ALARM SPEAKER SYSTEMS
Decades of experience in the installation of professional sound systems have taught us that the
impact of room acoustics on the speech intelligibility of sound events reproduced by speaker
systems is more than important. All new standards in voice alarm sound reinforcement also
require the compliance with respect to intelligibility values for announcements and CIS values
greater than 0,7. In practice however it means, that for sound installations of halls and stands,
the use of ceiling speakers, sound projectors and horn loudspeakers (even if certified) doesn’t
provide the desired results. Therefore we offer you for reverberant spaces strongly focusing sound
columnes and for high-performance full-range applications our highpower fullrange speakers
both as certified PA speakers. The most important ITEC PA speakers, which will be used within
100V full range applications as well as in voice alarm sound reinforcement systems, are currently
under certification
Certified High-Power Speaker Systems
Achieving good speech intelligibility- and high SPL-values are required by all of the appropriate
international standards. With „normal“ ceiling speakers, sound-projectors and hornspeakers
these requirements often can not be fullfilled, especially in highly reverberant rooms and halls.
This is the reason for we decided to bring a couple of our highpower sound columnes and some
of our fullrange highpower cabinets into certification acc. to EN 54-24 (in progress):
Die ITEC NeodymLine-Serie,
die ITEC NeoFocus-Serie,
der ITEC Monitor12 und
das ITEC PowerTop12/2