Telemetry 2014 - ACDC Dynamics

Transcription

Telemetry 2014 - ACDC Dynamics
TELEMETRY SYSTEMS
Short Form Catalogue 2013 I 2014
www.acdc.co.za
TELEMETRY SYSTEM - WIRELESS AND REMOTE IP20
VHF Radio Modem
Note: 2 units required for 2 way comms
Code
Description
Note: 2 units required for 2 way comms
Z-LINK1
Description
DL169 is a VHF simplex/halfduplex high quality radio modem
169.4mhZ band with output power
of 200mW (ERP) 6 x 12.5KHz
channels or 3 x 25KHz channels.
The Radioman is enclosed in an
extruded aluminium box containing
the RS232/ 485 interface and
supply unit card
Power Supply
Power Supply 8-36VDC
10-40VDC: 19-28VAC
RX: 30mA @ 12VDC,
Consumption
Consumption
1W @ 12VDC
TX: 300mA @ 12VDC
Isolation
1500VAC
LED Indicators Power Supply: Error: Data TX/RX LED Indicators Unit status, Data, Transmission
6 x 12.5KHz/ 3 x 25KHz
Connectors
Channels
RJ10 terminal for RS232 serial
4800bps @ 12.5KHz or
port Stereo Jack for programming Data Rate
9600bps @ 25KHz
Antenna. IDC10 Connector
Output Power 0.2WERP (Dipole) or 0.5 WERP
suitable for I/O linking. Screw
(Yagi)
terminals
5-24VDC or 3.5-20VAC (Zinp
Set-up
EASY SETUP (Software)
Digital I/P
2.2KΩ)
Mounting
DIN 35mm rail guide
Hot Swapping
Yes
Transmitter
Weight
200g
Freq. Deviation ±1.8KHz @ 12.5/ ±3.6KHz @
25KHz
Communications
± 1.5dB
Interface
1 x RS232: 1 x RS485
O/P Stability
100 x 90 x 40mm
Protocol
ModBUS RTU
Size
RS232 or RS485
Speed
1200 to 115200 baud
Interface
1200 - 38400bps
Connectivity
32 nodes
Data Rate
Asynchronous
Modulation
GFSK
Data Format
Simplex/ Half duplex
Mode
Half-Duplex
Mode
Power Output
20mW
Receiver
RS232 or RS485
Range
400m in open space
Interface
1200 - 38400bps
Frequency
869.4MHz - 869.65MHz
Data Rate
Asynchronous
Data Format
Accessories
Simplex/ Half Duplex
Programming cables: RJ10/ DB9F Mode
PM
serial cable
Antennas
Backplane power & bus
DL-169-IN-B ¼ wave Dipole
Z-PC-DIN
connections
DL-169-IN-B-Y3 (Yagi)
Programming software
EASY SETUP
10 element external antenna
A-DIR-10-869
(824-960MHz)
6 element external antenna
A-DIR-6-869
(824-960MHz)
ANT-LINK1-MG Dual band external magnetic
antenna
2
Z-Link1 is a 869MHz radio device
suitable to establish wireless
ModBUS communication. The
device is able to manage different
and seperate ModBUS networks
through MESH networks ensuring
a reliable coverage because of
structured interconnected nodes.
DL169-RS485 (RS485 Comms)
DL169-RS232 (RS232 Comms)
SENECA
Note: 2 units required for 2 way comms
Z-AIR
Description Z-AIR is a simplex/half duplex radio
modem with embedded coaxial
dipole antenna. The intergration of
the radio modem with the antenna
eliminates connection losses. The
use of an RS485 interfaceallows
for long cable runs (47mt at 12VDC
and 180mt at 24VDC). Z-AIR can
be used as transceiver systems or
repeaters to extended coverage
ranges
Power Supply 8 - 36VDC
Consumption Sleep mode 1μA, Rx 10mA
Tx 150mA
Protection Rating IP65
868 - 870MHz( With specified
RF Band
sub-bands)
Transmitter
Freq. Deviation ±1.8KHz @#12.5KHz / ± 3KHz @
25KHz
± ppm/° C
O/P Stability
Ø 40 x L 320mm
Size
RS485
1200 - 38400bps
Data Rate
Data Format Asynchronous
Simplex / Half Duplex
Mode
Receiver
Interface
Data Rate
Data Format
Mode
Antenna
RS485
1200 - 38400bps
Asynchronous
Simplex / Half Duplex
LBT (Listern -Before -Talk)
ʎ/ 2 Intergrated
4800bps @ 12.5KHz or 9600bps
@ 25KHZ
25mW-500mW Depending on
selected band
TELEMETRY SYSTEM - WIRELESS AND REMOTE IP20
Code
Description
Power Supply
Consumption
Isolation
Indicators
Connectors
Mounting
CPU
Memory
Size (wxhxd)
Interface
Protocol
Inputs
Digital Output
Configuration
Accessories
PM0002490
A-GSM
FD01
Z-PC-DIN
Z-PC-DINAL1
Z-PC-DINAL1
Z-GPRS2
ZGPRS2 Is a GSM / GPRS
multiprotocol wireless unit with
built in I/O’s for high performance
data acquisition, Datalogging,
Commands, Measurement and
Alarm management. Z-GPRS2
works as a stand alone or
networked unit. Master Modbus
unit on RS484 ports and GSM/
GPRS communications support.
11-40VDC: 19-28VAC
2W(standby), 6W (max)
500VAC
Ethernet, Data, Comm(TX/RX)
GSM, Power
RJ45 (10/100Mbps)
Rear: IDC10 connector
Srew clamp (max 2.5mm²)
Mini USB B-OST type Antenna
DIN 35mm rail guide
32 bit
Flash Memory 512k+2MB: RAM
128kB
35 x 100 x 112mm
RS232 / RS485
FTP, SMTP, POP3,HTTP, ModBUS
TCP, ModBUS RTU, Custom
Protocols
4 x Digital (PNP/NPN) , 2 x
Analogue
2 x SPDT relay 2A 250VAC max
Easy-Seal software
RS232 Programming cable
External GSM antenna
Photodetector for pulse counting
Baclplane power and bus
communications
Baclplane power and bus + 1
SLOT
Baclplane power and bus + 1
SLOT
MY2B
Description
MyAlarm2 is a GSM / GPRS
telecontrol unit for home, small
building industrial plant and
machine control through simple
commands sent by SMS text
message, Phone rings and Emails.
It works with any cell phone or
smartphone. Built-in temperature
Probe.
Power Supply 12VDC 100mA
Consumption 1.2 - 2 W
IP20
Protection
GSM / GPRS, Power
Indicators
Li-On (16-24 hr on full charge)
Battery
Graphic LCD 32x128 pixels
Display
4 x digital 2 wire, 1 x Analogue
Inputs
2 x relay 3A SPST
Output
Flash 2MB, Micro SD UP TO 32GB
Memory
Quad band 850/900/1800 /1900
GSM
MHz
80 x 105x 30mm
Size (wxhxd)
Removable terminal block 3.5mm
Connections
SIM card slot, Mini USB. Antenna,
Micro SD (UP to 32GB), GPS
High speed Mini USB 2.0 B TYPE
Phonebook
10 x Email + 10 x phone no. on
flash
10 x alarm email + 10 phone no.
On flash
Configuration 250 users on SIM
Accessories Easy Setup MyAlarm2 Software
MY2KITIP66 IP66 ABS Kit for field applications
WS-Contact Wireless Anti-Intrusion Sensor
Wireless Flood Sensor
WS-Water
Z-GATEWAY
Description
Z-Gatway is an industrial gateway
consisting of three main units:
1) ModBUS RTU Master- collects
data from RTU Slaves, 2) Buffer
Memory- stores data from RTU
Slaves, 3) ModBUS TCP- Monitors
requests from Ethernet registers
2 independant RS485 ports and 2
ModBUS TCP sockets. Configured
and upgraded via USB port.
Power Supply 10-40VDC: 19-28VAC
3.5W
Consumption
1500VAC PSU to remaining circuits
Isolation
LED Indicators Serial Connection IP/DHCP,
Ethernet Connection, Ethernet TX
Removable terminal block, USB
mini-B, Ethernet RJ45
Rear IDC10 connector for Z-PCConnectors
DIN backplane
Easy Setup software, Web Srever,
Set-up
DIP Switches
Baud rate
DIP-switches
DIN 35mm rail guide
Mounting
IP20
Protection
17,5 x 100 x 112mm
Sixe (wxhxd)
―
Memory
Communications
Interface
Protocol
Speed
Connectivity
Channels
Ethernet /RS485 remote control of
ModBUS RTU device
Ethernet 10Base T port (10Mbps)
Master RS485 /RS232 ModBUS
RTU protocol
Max baud rate for ModBUS RTU
set to 115200 bps
Connection for RS232 port DB9-F
in the side of module
―
―
Accessories
Backplane power and bus
Z-PC-DIN
Z-SUPPLY
Easy Setup
PM001450
SENECA
communications
Power supply
Programming Software
Ethernet Cable RJ45-RJ45
3
TELEMETRY SYSTEM - I/O MODULES IP20
Z-D-IN
Z-D-OUT
Z-10-D-IN
Z-D-IN is a 5 digital input with self powered
16VDC shared negative pole.The inputs
are protected by 600Ω W/ms TVS transient
current suppressors. The input channels have
100Hz 16 bit counters with settable filter. The
inputs can also be set as fast 32 bit totalizer
with max frequency of 10kHz. RS485 serial
communication Supports ModBUS-RTU
protocol maximum 32 nodes.
Z-D-OUT is a 5 SPST relay output module
with common line relay capacity 5A 250VAC
resistive / 2A inductive. Z-D-OUT offers
possiblity of setting relay status at start-up. The
module also allows safety time stting from 0.5
to 2.5s. RS485 serial communications supports
ModBUS-RTU protocol with maximum 32
nodes.
Z-D-IN is a 10 digital input with self powered
16VDC shared negative pole. Z-10-D-IN has 8
x 16 bit input counters max freq 100Hz. 2 x 32
bit input counters max freq 10kHz.Forward or
reverse counting options are available with total
overflow indication for each total counter
10-40VDC: 19-28VAC
2.5W
1500VAC
Power Supply:Error: Data Transmission/
Reception, Input status
Removable terminal block, plug-in connectors
Rear IDC10 connector for Z-PC-DIN backplane
Z-NET3, EASY Z-D-IN (plug&platy)
Baud rate, node, parity, serial port, termination
line,Bit stop
DIN 35mm rail guide
IP20
17,5 x 100 x 112mm
EEPROM for config parameters, 5 x 16 bit
registers, 5 x bit overflow
10-40VDC: 19-28VAC
2.5W
1500VAC
Power Supply:Fail: Data Transmission/
Reception, Outputt status
Removable terminal block, plug-in connectors
Rear IDC10 connector for Z-PC-DIN backplane
Z-NET3, EASY Z-D-IN (plug&platy)
Baud rate, node, parity, serial port, termination
line,Bit stop
DIN 35mm rail guide
IP20
17,5 x 100 x 112mm
EEPROM for config parameters, 5 x 16 bit
registers, 5 x bit overflow
10-40VDC: 19-28VAC
1.5W
1500VAC
Power Supply:Error: Data Transmission/
Reception, Input status
Removable terminal block, plug-in connectors
Rear IDC10 connector for Z-PC-DIN backplane
Z-NET3, EASY Z-10-D-IN (plug&platy)
Baud rate, address, inversion scale, digital
filter,totalizer.
DIN 35mm rail guide
IP20
17,5 x 100 x 112mm
2 wire RS485
ModBUS RTU slave
Up to 57600 bps
<10ms (38400 baud)
32 nodes
5 x Opto-isolated for REED, PROXIMITY, PNP,
NPN, contacts etc
Bounce filters 5-200ms
4 x 16 bit input with counting function
(max freq 100Hz)
1 x 16 bit input with counting function
(max freq 10kHz)
2 wire RS485
ModBUS RTU slave
Up to 57600 bps
<10ms (38400 baud)
32 nodes
5 x SPST NO relay with common line max
rated current 5A
Max voltage 250VAC
Relay coil voltage 24VDC
Relay release time 2ms
2 wire RS485
ModBUS RTU slave
Up to 57600 bps
<10ms (38400 baud)
32 nodes
10 x self powered 16VDC shared negative
polre
REED , Contact, sensors, proximity PNP, NPN
2 x 32 bit input counters 10kHz
8 x 16 bit input counters 100Hz
Min pulse width 4ms - 50µs
Backplane power and bus communications
Power supply
Programming software
Programming Software
Backplane power and bus communications
Power supply
Programming software
Programming Software
Backplane power and bus communications
Power supply
Programming software
Programming Software
Code
Description
Specifications
Power Supply
Consumption
Isolation
LED Indicators
Connectors
Set-up
Dip Switches
Mounting
Protection
Size (wxhxd)
Memory
Communications
Interface
Protocal
Speed
Comms time
Connectivity
Channels
Accessories
Z-PC-DIN
Z-SUPPLY
EASY SETUP
Z-NET3
4
SENECA
TELEMETRY SYSTEM - I/O MODULES IP20
Z-10-D-OUT
Z-D-IO
Z-DAQ-PID
Z-10-D-OUT offers 10 x Opto-isolated Mosfet
outputs. The digital output maximum load is
0.5A resistive/ inductive. Maximum switch on/
off frequency is 2 cycles per sec. The module
is a ModBUS Slave and can be coupled with
any ModBUS Master device. 3 way isolation
between Power/ Output/ RS485 circuits
assures data integrity.
Z-D-IO has 6 digital inputs and 2 x SPST relay
outputs. It can be used as a simple I/O module
or by setting DIP switches special functions
can be activated to drive motors, pneumatic
valves etc. The unit is ModBUS slave and can
be coupled with any ModBUS Master device 3
way isolation between Power/ Output/ RS485
circuits assures data integrity.
Z-DAQ-PID has universal analogue input (Ma,
V, PT100, TC, Ohm) and active 4/20mA or 0/
20mA output for continuous or PWM (Pulse
Width Modulated) loop control. This function
can be cancelled and the unit performs as
analogue I/O device. The unit can be coupled
with any ModBUS Master device. 3 way
isolation between Power/ Output/ RS485
circuits assure data integrity.
10-40VDC: 19-28VAC
1.5W
1500VAC
Power Supply: Error: Data Transmission/
reception, input status
Removable terminal block, plug-in connectors.
Rear IDC10 connector for Z-PC DIN backplane
Z-NET3, EASY SETUP
Baud rate, node, parity, serial port, termination
line, Bit stop
DIN 35mm rail guide
10-40VDC: 19-28VAC
2.5W
1500VAC
Power Supply: Error: Data Transmission/
reception, input status
Removable terminal block, plug-in connectors.
Rear IDC10 connector for Z-PC DIN backplane
Z-NET3, EASY SETUP
Baud rate, node, parity, serial port, termination
line, Bit stop
DIN 35mm rail guide
EEPROM for configuration settings: 5 x 16 bit
registers, 5 x overflow
10-40VDC: 19-28VAC
2W
1500VAC
Power Supply: Error: Data Transmission/
reception, input status
Removable terminal block, plug-in connectors.
Rear IDC10 connector for Z-PC DIN backplane
EASY SETUP
Baud rate, node, parity, serial port, termination
line, Bit stop
DIN 35mm rail guide
EEPROM for configuration settings: 5 x 16 bit
registers, 5 x overflow
2 wire RS485
ModBUS RTU slave
Up to 115200 bps
<10ms (38400 baud)
32 nodes
10 x Opto-isolated Mosfet with short circuit and
overvoltage protection between 6 - 40VDC
2 wire RS485
ModBUS RTU slave
Up to 115200 bps
<10ms (38400 baud)
32 nodes
8 x Opto-isolated inputs for Reed,Proximity,
PNP, NPN switches 2 x SPST (5A 250VAC)
outputs
2 wire RS485
ModBUS RTU slave
Up to 115200 bps
<10ms (38400 baud)
32 nodes
1 x analogue input 0-10V or 0-20/ 4 - 20mA:
Potentiometer (1KΩ-100KΩ):
TC (J,K,R,S,T,B,E,N)
1 x analogue output 0-5V, O-10V: 0-20mA/
4-20mA Conversion with or without PID,
Analogue O/P without PID, Special PWM
Pulse. Width Modulation
Backplane power and bus communications
Power supply
Programming software
Programming software
Backplane power and bus communications
Power supply
Programming software
Programming software
Backplane power and bus communications
Power supply
Programming software
Programming software
Code
Description
Specifications
Power Supply
Consumption
Isolation
LED Indicators
Connectors
Set-up
Dip Switches
Mounting
Memory
Communications
Interface
Protocal
Speed
Comms time
Connectivity
Channels
Accessories
Z-PC-DIN
Z-SUPPLY
EASY SETUP
Z-NET3
SENECA
5
TELEMETRY SYSTEM - I/O MODULES IP20
Z-4AI
Z-8AI
Z-3AO
Z-4AI is used to interface analogue inputs
(voltage or current) with ModBUS systems.
The module can supply all 4 loops at the
same time (useful for 2 wire sensors because
external power is not required. The unit is
a ModBUS Master Device. 3 way isolation
between power/ Output/ RS485 circuits
assures data integrity.
Z-8AI is used to interface analogue inputs
(voltage or current) with ModBUS systems.
The module can supply all 8 loops at the
same time (useful for 2 wire sensors because
external power is not required. The unit is a
ModBUS slave and can be coupled with any
ModBUS Master Device. 3 way isolation
between Power/ Output/ RS485 circuits
assures data integrity.
Z-3AO can supply 3 analogue outputs
(V or mA) from a ModBUS system. The
standard can be either mA (0-20mA/ 4-20mA)
or V (-10-10V, 0-10V or 2-10V). 3 way isolators
between power/ output/ RS485 circuits
assures data integrity.
10-40VDC: 19-28VAC
2.5W
1500VAC
Power Supply: Error: Data Transmission/
reception, input status
Removable terminal block, plug-in connectors.
Rear IDC10 connector for Z-PC DIN backplane
EASY SETUP
Baud rate, address, input type
DIN 35mm rail guide
EEPROM for configuration settings
10-40VDC: 19-28VAC
3.5W
1500VAC
Power Supply: Error: Data Transmission/
reception, input status
Removable terminal block, plug-in connectors.
Rear IDC10 connector for Z-PC DIN backplane
EASY SETUP
Baud rate, address, input type
DIN 35mm rail guide
EEPROM for configuration settings
10-40VDC: 19-28VAC
2.5W
1500VAC
Power Supply: Error: Data Transmission/
reception, input status
Removable terminal block, plug-in connectors.
Rear IDC10 connector for Z-PC DIN backplane
EASY SETUP
Baud rate, address, input type
DIN 35mm rail guide
EEPROM for configuration settings
2 wire RS485
ModBUS RTU slave
Up to 115200 bps
<10ms (38400 baud)
32 nodes
4 x analogue inputs:
Voltage Bipolar inputs full scale ± 2 or ±
10VDC: 100KΩ
Current bipolar full scale ±20mA
2 wire RS485
ModBUS RTU slave
Up to 115200 bps
<10ms (38400 baud)
32 nodes
8 x analogue inputs:
Voltage Bipolar inputs full scale ± 2 or ±
10VDC: 100KΩ
Current bipolar full scale ±20mA
2 wire RS485
ModBUS RTU slave
Up to 57600bps (RS485)/ 2400bps (RS232)
<20ms (38400 baud)
32 nodes
3 x analogue inputs:
Voltage Bipolar inputs full scale settable at -10V
- 10V, 0 - 10V, 2-10V
Current: full scale settable at 0 - 20mA or
4 - 20mA
Backplane power and bus communications
Power supply
Programming software
Backplane power and bus communications
Power supply
Programming software
Backplane power and bus communications
Power supply
Programming software
Code
Description
Specifications
Power Supply
Consumption
Isolation
LED Indicators
Connectors
Set-up
Dip Switches
Mounting
Memory
Communications
Interface
Protocal
Speed
Comms time
Connectivity
Channels
Accessories
Z-PC-DIN
Z-SUPPLY
EASY SETUP
6
SENECA
TELEMETRY SYSTEM - TEMPERATURE INPUT MODULES IP20
RTD Input
Specifications
Power Supply
Consumption
Isolation
LED Indicators
Connectors
Set-up
Dip Switches
Mounting
Memory
Z-4TC
Z-8TC
Z-4RTD-2 is an interface for RTD sensors
(PT100, PT1000, PT500, Ni100) with 2, 3
or 4 wires. The unit has 4 inputs and each
input is independant of eachother. The unit
is a ModBUS slave and can be coupled with
any ModBUS master device. 6 way galvanic
isolation between power supply/ input/ RS485
circuits assures data integrity.
Z-4TC is a interface for themocouple sensor
type (J,K,E,N,S,R,B,T) and any generic sensor
with a mV signal output. The module has 4
input channels that are all independant of each
other. The unit is a ModBUS slave and can be
coupled with any ModBUS master device. 3
way isolation between power/output/ RS485
circuits assures data integrity.
Z-8TC is an interface for thermocouple sensor
type (J,K,E,N,S,R,B,T) and any generic sensor
with mV signal output. The module has 8 input
channels that are all independant of each
other. The unit is a ModBUS Slave and can be
coupled with any ModBUS Master device. 6
way isolation between power/ output/ RS485
circuits assures data integrity.
10-40VDC: 19-28VAC
0.7W
1500VAC
Power Supply: Error: Data Transmission/
reception, input status
Removable terminal block, plug-in connectors.
Rear IDC10 connector for Z-PC DIN backplane
EASY SETUP
Baud rate, address
DIN 35mm rail guide
EEPROM for configuration settings
10-40VDC: 19-28VAC
2.5W
1500VAC
Power Supply: Error: Data Transmission/
reception
Removable terminal block, plug-in connectors.
Rear IDC10 connector for Z-PC DIN backplane
EASY SETUP
Baud rate, address
DIN 35mm rail guide
EEPROM for configuration settings
10-40VDC: 19-28VAC
0.6W
1500VAC
Power Supply: Error: Data Transmission/
reception
Removable terminal block, plug-in connectors.
Rear IDC10 connector for Z-PC DIN backplane
EASY SETUP
Baud rate, address
DIN 35mm rail guide
EEPROM for configuration settings
2 wire RS485
ModBUS RTU slave
Up to 57600bps (RS485)/ 2400bps (RS232)
<20ms (38400 baud)
32 nodes
3 x analogue outputs:
Voltage Bipolar with settable full scale at
-10V - 10V, 0 - 10V, or 2 - 10V
Current: full scale settable at 0 - 20mA or
4 - 20mA
2 wire RS485
ModBUS RTU slave
Up to 57600bps (RS485)/ 2400bps (RS232)
<20ms (38400 baud)
32 nodes
4 x mV thermocouple inputs
Voltage: Bi-Polar with ± 160mV range
2 wire RS485
ModBUS RTU slave
Up to 57600bps (RS485)/ 2400bps (RS232)
<20ms (38400 baud)
32 nodes
8 x mV thermocouple inputs
Voltage: -10, 1-81, 4mV
Backplane power and bus communications
Power supply
Programming software
-
Backplane power and bus communications
Power supply
Programming software
Programming software
Backplane power and bus communications
Power supply
Programming software
Programming software
Communications
Interface
Protocal
Speed
Comms time
Connectivity
Channels
Accessories
Z-PC-DIN
Z-SUPPLY
EASY SETUP
Z-NET3
TC Input
Z-4RTD-2
Code
Description
TC Input
SENECA
7
TELEMETRY SYSTEM - MULTI-FUNCTION CONTROL UNITS IP20
Webserver/ PLC
Webserver/ PLC
Z-TWS-3
Z-TWS-64
Z-SG
Z-TWS-3 has a powerful on board PLC and
Ethernet Interface and webserver capabilities.
ModBUS RTU Master or slave Connection
with external HMI possible through the serial/
Ethernet interface
Z-TWS-64 has a powerful on board PLC with
webserver capabilities and Ethernet interface
ModBUS RTU Master or slave Connection
with external HMI possible through ther serial/
Ethernet interface.
Z-SG is a strain gauge signal convertor.
Sensitivy from 1 - 64mV/V settable by DIP
switch. Stable weight indication via ModBUS
register/digital output. Remote writing of TARE
in volatile/non volatile memory
via ModBUS tregister/commands
10-40VDC: 19-28VAC
3.5W
1500VAC
PSU: Ethernet connection, PLC on:
Ethernet link
Removable terminal block, plug-in connectors.
Rear IDC10 connector for Z-PC DIN backplane
EASY Z-4RTD2 SETUP
Baud rate, address
DIN 35mm rail guide
10-40VDC: 19-28VAC
2.5W
1500VAC
Power Supply: Error: Data Transmission/
reception
Removable terminal block, plug-in connectors.
Rear IDC10 connector for Z-PC DIN backplane
EASY Z-4TCSETUP
Baud rate, address
DIN 35mm rail guide
10-40VDC: 19-28VAC
2.5W
1500VAC
Power Supply:Error: Data Transmission/
Reception
Removable terminal block
Rear IDC10 connector for Z-PC-DIN backplane
DIN 35mm rail guide
IP20
17,5 x 100 x 112mm
1 x Ethernet 10 base T (RJ45), 1 x RS232 via
RJ10-4/ 4.
O x RS485-ModBUS, 1 x RS232/ 485 via
RJ10-4/ 4
1200-11500bps
PP, http, FTP, SMTP, ModBUS RTU,
ModBUS TCP/ IP
Ethernet TCP-IP (10Mbps)- ModBUS TCP-IP
(client server)
ModBUS RTU on RS232/ RS485 Master/ slave
Parity: None, Even, Odd
1 x Ethernet 10 base T (RJ45), 1 x RS232 1 x 2 wire RS485
RS232 via RJ10-4/ 4, 1 x RS232 via RJ10-4/ 4 ModBUS RTU slave
Processing
Flash memory
RAM
Timers
Counters
Retentive Variable
CPU RISC 32Bit - 20MIPS
16MB (O of which 14 MB are for datalogging)
8MB
2046 bytes
CPU RISC 64bit - 70MIPS
128MB
64MB
1600
1600
2046 bytes
Z-NET-3
Z-NET RTU
Wed editor, Data recorder, Trend viewer
OPC server, IEC 870 (remote control)
Isagraf, CoDeSys, Seneca Libraries
Wed editor, Data recorder, Trend viewer
OPC server, IEC 870 (remote control)
PLC/ Isagraf
Code
Description
Specifications
Power Supply
Consumption
Isolation
LED Indicators
Connectors
Set-up
Dip Switches
Mounting
Communications
Interface
Speed
Comms
Connectivity
Processing and memory
Programming
Z-PC-DIN
Z-SUPPLY
Z-NET
8
Remote terminal unit
1200-11500bps
PP, http, FTP, SMTP, ModBUS RTU, ModBUS
TCP/ IP
Ethernet TCP-IP (10Mbps)- ModBUS TCP-IP
(client server)
ModBUS RTU on RS232/ RS485 Master/ slave
Parity: None, Even, Odd
SENECA
Up to 57600bps (RS485)/ 2400bops (RS232)
Up to 57600bps (RS485)/ 2400bops (RS232)
32 nodes
Accessories
Z-PC-DIN: Backplane power and bus
communications
Z-SUPPLY: Power supply
EASY SETUP: Programming Software
SG-EQ4: loadcell connection & equalisation
system
Programming
EASY Z-SG(plug&play)
TELEMETRY SYSTEM - MULTI-FUNCTION CONTROL UNITS IP20
Remote terminal unit
Z-Bridge2
Z204
Code
Description
Specifications
Power Supply
Consumption
Isolation
LED Indicators
Connectors
Set-up
Dip Switches
Mounting
Protection
Size (wxhxd)
Memory
Accessories
Z-PC-DIN
Z-SUPPLY
EASY SETUP
PM001450
Z-107
Z-204 accepts alternating or direct voltage
(up to 100V) TRMS and provides an isolated
analogue output (Ma/V) alternatively the output
is available as ModBUS-RTU interface 3
way isolation between Power/ output/ RS485
circuits assures data integrity
Z-BRIDGE2 is a serial protocol converter
from ModBUS RTU to ModBUS TCP/IP, with
2 x RS484 Ports, 1 x Ethernet port and 1 x
USB port. Protocols supported are ModBUS
RTU master on RS485/RS232 and ModBUS
TCP/ IP server on the Ethernet network.
RS485 ports are individually configured (from
600 to 115200bps). The IP address can be
static or configured for DHCP (Dynamic Host
Config. Protocol)
Z-107 allows for a transparent and isolated
bi-directional conversion of RS485/ RS232
serial line into RS232. The RS232 connection
is available on both terminal and RJ10
connection, The RS485 connection is available
on terminal and rear connector
10-40VDC
1.0W
4000VAC between input and power supply/
output ports
Power Supply: Failure: RS485 connections
10-40VDC: 19-28VAC
3.5W
500VAC (PSU/ Serial Port/ Ethernet)
10-40VDC: 19-28VAC
2.5W
1500VAC
Serial comms, IP/DHCP connection Ethernet
TX/RX
Removable terminal block, plug-in connectors. Removable terminal block, USB mini-B,
Ethernet RJ45. Rear IDC10 connector for
Rear IDC10 connector for Z-PC DIN
Z-PC-DIN backplane
backplane
EASY SETUP, Web server, DIP switches
EASY 204
Baud rate, address, line termination, input range Baud Rate
DIN 35mm rail guide
DIN 35mm rail guide
IP20
IP20
175.5 x 100 x 112mm
175.5 x 100 x 112mm
CPU 32 bit, 512kB fLASH, 128Kb RAM,
Back-up battery
Power Supply: RST signal status: data
transmission/ reception
Removable terminal block, plug-in
connectors. Rear IDC10 connector for Z-PC
DIN backplane
DIP switches
Speed, communication, change from direction
DIN 35mm rail guide
IP20
175.5 x 100 x 112mm
-
2 wire RS485 (alternative to analogue output)
RS232: No Parity, 8 data bits 1 stop bit
1200-115200baud
1 x input 0-300, 0-600, 0-1000VAC/DC
1 x output voltage 0-10V (Min load 2.5kΩ)
1 x current 0-20mA/ 4-20mA (Max load 600Ω)
1 x Ethernet, 2 x RS485, 1 x USB mini
ModBUS RTU Master, ModBUS TCP-IP/ http
600 to 115200bps
http, FTP
-
RS232 on RJ45, RS485/ 422 on terminals
ModBUS RTU slave
Up to 115kbps
2 wire half duplex, point to point, multidrop
-
Backplane power and bus communications
Programming software
Programming cable
Backplane power and bus communications
Power supply
Programming software
Ethernet cable
Backplane power and bus communications
Power Supply
-
Communications
Interface
Protocol
Speed
Connectivity
Channels
Z-BRIDGE2
SENECA
9
TELEMETRY SYSTEM - POWER ANALYSERS/POWER SUPPLY IP20
Z203-1
S203TA
Z-SUPPLY
Z-203-1 is a single phase network analyser
suited for use up to 500VAC and 5A max
current. The unit provides the following
measureable VRMS, IRMS, Watt, Var,
Va, Frequency, CosØ. Measurements are
available via ModBUS serial comms analogue
re-transmission (mA or V). 3 Way galvanic
isolation for Power supply/ input/ RS485
assures data integrity.
S203TA is a complete three phase network
analyser suited for use up to 600VAC and 5A
max current. The unit provides the following
measurable variables VRMS, IRMS, Watt,
Var, Va, Frequency, CosØ. Measurements are
available via ModBUS serial comms analogue
re-transmission (mA or V) 3 way galvanic
isolation for power supply/ input/ RS485
assures data integrity.
Z-SUPPLY is a single-phase power supply
with AC/DC input of 110VAC - 230VAC
47-63Hz, 0.7A./ 110VDC-315VDC 0.7A.
Z-SUPPLY output voltage is 24VDC 1.5A ± 2%,
available on terminals and IDC connector at
base of unit for connection to Z-PC-DIN. The
unit is protected against over-current/ voltage
by internal fuse, 1.25A type T (slow blow).
10-40VDC, 19-28VAC
2W
1500VAC
Power supply, Error, Data transmission/
reception
Terminals, IDC10 connector for Z-PC
backplane
35mm DIN rail
EASY 203 SETUP
Address, Baud rate, Analogue output
2 x inputs 0-5A, 0-500VAC
1 x output configured as VRMS, IRMS, P, Q,
CosØ Max load 2.5kΩ
0-20/ 4-20mA Max load 600Ω
10-40VDC, 19-28VAC
2W
1500VAC
Power supply, Error, Data transmission/
reception
Terminals
110-230VAC/ 110-350VDC
No load 1.4W/ Full load 6.6W
3000VAC/ 60sec
Power supply, output status
RS485 1200 - 115200 baud
RS232 2400 baud address 01, parity No, 8
data bits
1 stop bit
ModBUS RTU Slave
RS485 1200 - 115200 baud
RS232 2400 baud address 01, parity No, 8
data bits
1 stop bit
ModBUS RTU Slave: 32 nodes
Code
Description
Specifications
Power Supply
Consumption
Isolation
LED Indicators
Connectors
Mounting
Set-up
Dip Switches
Channels
Communications
Interface
Protocal
35mm DIN rail
EASY 203 SETUP
Address, Baud rate, variable output
1 x input, 1 x output + RS485 RTU Slave
+ analogue. Address setting, baud setting,
measuring variable. Select 3 phase or single
phase
Terminals, IDC10 connector for Z-PC
backplane
35mm DIN rail
PROGRAMMABLE HEAD MOUNT TEMPERATURE TRANSMITTER (LOOP POWERED)
Code
Description
T121
Programmable using Programming Kit S117 (see accessories)
Input: PT100, Ni100, PT500, PT1000, J, K, R, S, T, B, E, N thermocouples
Power supply 7 - 30 VDC
Current output 4/20 or 20/4mA (2 wire)
Resolution 2μA (>13bit)
Response time >1s
Over range fault output 102.5 - 105% full scale
Connection by spring terminals (wire size 0.2-0.25mm² )
Size 20mm x 43.7mmØ
10
SENECA
ACCESSORIES
Description
Code
Z-PC-DINAL2-17.5 head+2slots
Z-PC-DIN2-17.5 2slots
Z-PC-DIN8-17.5 8slots
Z-PC-DINAL2-35 head+1slots
Z-PC-DIN1-35 1slots
Z-PC-DIN4-35 4slots
S401-L
Code
OLED brightness display: 2,7"
Interfaces:
1 x RS485 Modbus Master +
1 x RS485 Modbus Slave
Direct connection with I/O Modules
20 query functions (incl addition, subtraction,
square, cube etc)
Dimension: 96 x 48 x 25 (W*H*D) mm
Activation alarm output
Z-POWER-230/15A
Z-POWER-230/25A
Z-POWER-115/15A
Input supply 230 or 115VAC
Output 19VAC
Clips onto 35mm DIN Rail
Z-PC DIN supports hot swapping
Available with 2, 4 or 8 plug in slots
For 17.5mm or 35mm wide modules
Clips onto 35mm DIN rail
Data Recorder Software
Easy Setup Software
S117P-1
Plug & Play set-up software for programmable Programming kit for head mount temperature
Data acquisition visualisation and recording
software. Simultaneous visualisation of up to 8 devices
transmitters.
Auto update from the web real time testing
channels per page
Consists of : Serial Cables, USB to RS232/
TTL, Cofiguration software
CABLE ACCESSORIES
Code
PM001420
PM001430
PM001440
PM001450
PM001460
PM001530
PM001601
PM002350
PM002460
PM002470
PM002480
PM002490
PM002500
PM002510
PM002520
PM002530
Description
Terminal Type
RS232 serial cable (Z-TWS, Z-RTU, Z107, Z-LINK)
RJ10/ DB9F
Modem communication cable (Z-TWS)
RJ10/ DB25M
Modem and HMI communication cable (ZTWS, Z-RTU)
RJ10/ DB25M
Ethernet cable-right (Z-TWS - network device)
RJ45/ RJ45
Crossing Ethernet cable ( Z-TWS-PC)
RJ45/ RJ45
Modem serial cable (Z-TWS, Z-RTU)
RJ10/ DB9M
Programming serial cable (Z-4AI-D, Z-4TC-D, Z8AI, Z-8TC, Z-4RTD2, Z-SG, Z203)
Jack/ DB9F
RS485 serial cable for Radiomodem
DB9M/ Bolt Heads
RS485 serial cable TP-WIRE (Z-TWS)
Tp-wire/ Bolt heads
Serial cable (Z-TWS, Z-RTU, Z107)
RJ10/ RJ10
RS485 Serial cable (Z-TWS)
RJ10/ Bolt heads
RS232 Serial cable - programming (Z-RTU, M-RTU, Radiomodem)
DB9M/ DB9F
RS232 modem for firmware updating (ZRTU, M-RTU, Radiomodem)
DB9M/ DB9F
Serial cable for Radiomodem
DB9F/ Puntali
Serial cable
DB9M/ DB9M
Serial cable
DB9F/ DB9F
SENECA
11
SIGNAL CONVERTERS
Programmable Signal Converter
Analogue to Frequency
Z104
Z111
Z109 REG-BP Is a single channel isolated
intelligent analogue signal converter.
Inputs can be programmed for mV, mA,
Thermocouple, RTD, Potentiometer, Reostat
or NTC.
Sampling rates are variable between 240sps
at 11bit to 15sps at 15bit.
Z104 converts current or voltage input to
frequency pulse train output.
The output can be programmed to range from
1 pulse every 2 hours to 10kHz.
3 way isolation between Power Supply / Input
/ Output assures integrity of datas.
Z111 converts frequency pulse train input to a
mA / V output.
The input is programmable to range from 1mHz
to 9.99kHz.
Can be programmed via DIP switch.
3 way isolation between Power Supply / Input /
Output assures integrity of datas.
Power Supply
Consumption
Isolation
LED Indicators
10-40VDC, 19-28VAC
2W
1500v
Power Supply, Alarm
10-40VDC, 19-28VAC
2.5W
1500VAC
Power Supply, Error, Data TX/RX Input Status
10-40VDC, 19-28VAC
2.5W
1500VAC
Power Supply, Error, Data TX/RX Input Status
Connectors
Terminals, USB
Terminals
Terminals
Mounting
Set-up
Dip Switches
Channels
DIN Rail
DIP Switch and PC
Analogue Input and Output
1 x Input / Output
DIN Rail
DIP Switch and PC
Analogue Input and Output
1 x Input / Output
DIN Rail
DIP Switch and PC
Analogue Input and Output
1 x Input / Output
Code
Description
Specifications
Input
Output
Z109 REG-BP
Frequency to Analogue
Programmable:- mV, mA, RTD, NTC, Reostat, Voltage 0 - 5 / 1 - 5 / 0 - 10 / 2 - 10V
Min Load 1kΩ
Potentiometer, Thermocouple
Current 0 - 20 / 4 - 20mA
Max Load 600Ω
Voltage -10 to 10V min load 1kΩ
Current -20 to 20mA max load 500Ω
NPN open collector 30VDC, 300mA
Reed relay 30VAC/DC 100mA
Note 1:- USB / Micro USB Cable required
Software free downloadtt
12
SENECA
Pulses Contact / Reed / NPN 2/3 wire with
24VDC . Namur / Hall Effect / 24VDC TTL.
Max frequency 10kHz
Voltage 0 - 5 / 1 - 5 / 0 - 10 / 2 - 10V
Min Load 1kΩ
Current 0 - 20 / 4 - 20mA
Max Load 600Ω
NOTES
SENECA
13
HEAD OFFICE
NATIONAL
P.O. Box 3812, Edenvale
1610, South Africa
26 Nguni Drive [email protected]
Longmeadow Estate West Tel: 010 202 3300
Edenvale, Gauteng Fax: 087 807 5441
South Africa www.acdc.co.za
Sales
Technical
Tel: 010 202 3400
Tel: 010 202 3500
Germiston
Cape Town
Pinetown
Riverhorse
Tel: 011 418 9600
Tel: 021 510 0710
Tel: 031 700 4215
Tel: 031 492 4800
www.acdc.co.za
1st Edition 2014
Distributed by:
AC/DC SFC TELEMETRY
Distributors and Franchises throughout Southern Africa