14 FLAT100SFLAT150S Flat Fan Range 3 /h (15l/s)- with the Building Regulations (Document F). bathrooms and 216m3/h (60l/s) - kitchens to comply fixing kit. Suitable for wall or panel mounting using the appropriate cloakrooms and kitchens. Slim profile only 15mm. 100mm and 150mm panel axial fans for bathrooms, Product type Single speed axial fan with electronic over-run timer – up to 30 mins and integral backdraught shutters FLAT100T A Ø C D B Single speed axial fan with integral backdraught shutters for remote or light switch operation Performance Graph A Dimensions FLAT150S Kitchen & Utility room Fans Single speed axial fan with integral backdraught shutters for remote or light switch operation FLAT100S Bathroom & toilet Fans Cat. No. Technical Details PRODUCT FLAT100S FLAT100T FLAT150S FLAT150T A 159 159 225 225 Dimensions (mm) B 15 15 15 15 C 98 98 144 144 D 70 70 93 93 150mm (6") Range Maximum pressure: 50 p.a. Sound volume: 45.0 dB(A) Maximum operating temperature: 40ºC 100mm (4") Range Maximum pressure: 20 p.a. Sound volume: 38.0 dB(A) Maximum operating temperature: 40ºC Additional Data 220-240V - AC. 50Hz . Single phase consuming 14 watts on the 100 series and 16 watts on the 150 series. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor. Electrical Flat Fan series packed in outers of 10. Contact our technical department for packaging dimensions Packaging 15 technical 16 LP100/LP120/LP150 Lo Profile Range 3 3 /hr or 36 litres per second - 120mm (5") 230m3/ hr or 64 litres per second - 150mm (6"). rates of 85m /hr or 23 litres per Circular Front Covers. ventilation (F1). to comply with the 2006 building regulations on room. flush fitting allows the fan to blend into the decor of the enables it to fit unobtrusively into any wall or ceiling. Its The Manrose Lo Profile fan has a unique design which Product type LP100/120/150STC electronic timer (1-20 mins) - Chrome C B A A A D Dimensions LP100/120/150S Series Square Grille Dimensions LP100/120/150 Series For the Circular & Square Grille (A) LP100 Series 85m /hr, 23 litres per second (B) LP120 Series 130m3/hr, 36 litres per second (C) LP150 Series 230m3/hr, 64 litres per second 3 Performance Graph Dimensions LP100/120/150C Series Circular Grille A LP100/120/150CLVC Low Profile STD (low voltage) - Chrome LP100/120/150CLVB Low Profile STD (low voltage) - Brass LP100/120/150CLVW Low Profile STD (low voltage) - White LP100/120/150CTC electronic timer (1-20 mins) - Chrome LP100/120/150CTB electronic timer (1-20 mins) - Brass LP100/120/150CTW electronic timer (1-20 mins) - White LP100/120/150CSC Low Profile Standard model for remote switching - Chrome LP100/120/150CSB Low Profile Standard model for remote switching - Brass LP100/120/150CSW Low Profile Standard model for remote switching - White CIRCULAR Front Cover LP100/120/150SLVC Low Profile STD (low voltage) - Chrome LP100/120/150SLVB Low Profile STD (low voltage) - Brass LP100/120/150SLVW Low Profile STD (low voltage) - White LP100/120/150STB electronic timer (1-20 mins) - Brass Low Profile Standard model for remote switching - Chrome LP100/120/150SSC LP100/120/150STW electronic timer (1-20 mins) - White Low Profile Standard model for remote switching - Brass LP100/120/150SSB LP100/120/150SSW Low Profile Standard model for remote switching - White Square Front Cover Cat. No. Technical Details PRODUCT A LP100S 140 LP100C 140Ø LP120S 161 LP120C 165Ø LP150S 191 LP150C 198Ø B 100 100 122 122 122 122 Dimensions (mm) C 10 10 10 10 10 10 D 98Ø 98Ø 118Ø 118Ø 150Ø 150Ø 150mm (6") Range Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m. Sound volume: 40.0 dB(A) Maximum operating temperature: 40ºC 120mm (5") Range Maximum pressure: 35 p.a. Fan speed: 2000 r.p.m. Sound volume: 41.0 dB(A) Maximum operating temperature: 40ºC 100mm (4") Range Maximum pressure: 20 p.a. Fan speed: 2400 r.p.m. Sound volume: 41.0 dB(A) Maximum operating temperature: 40ºC Additional Data 220-240V - AC. 50Hz . Single phase consuming 14 watts (100mm) and 17 watts (120/150mm). These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor. Electrical Designed for wall or ceiling mounting through either 100mm(4"), 120mm(5"), 150mm(6") diameter flexible or rigid pipes or Manrose low profile, flat channel ducting systems. Installation In outers of 10, for packaging dimensions contact our technical department. Packaging 17 technical 18 Rtdeco100 & Rtdeco150 Rtdeco Range rates of 75m3 ventilation (F1). to comply with the 2006 building regulations on 3 /hr As Above With Aluminium Front Cover DECO150HC 5 0 0.5 0 Rtdeco150 Range 220m3/hr, 62 litres per second Performance Graph 10 1 10 15 20 25 30 Volume I/Sec 15 5 20 2 1.5 0 25 30 2.5 3 0 Volume m3/hr 20 40 60 80 100 Rtdeco100 Range 75m³/hr, 20 litres per second Performance Graph As Above With Aluminium Front Cover Humidity Fan With Integral DECO150HW With Integral Timer DECO150TC DECO150TW Static pressure mm WG Static pressure Pa Standard Fan As Above With Aluminium Front Cover DECO150SC As Above With Aluminium Front Cover DECO100HC DECO150SW As Above With Aluminium Front Cover Humidity Fan With Integral Timer DECO100HW With Integral Timer DECO100TW DECO100TC Standard Fan As Above With Aluminium Front Cover DECO100SC Product type DECO100SW Cat. No. Technical Details Product Rtdeco100 Rtdeco150 A 140 191 Dimensions (mm) B 105 122 C 30 10 D 98 150Ø Maximum operating temperature: 40ºC Sound volume: 40.0 dB(A) Fan speed: 2400 r.p.m Maximum pressure: 50 p.a 150mm (6") Range Maximum operating temperature: 40ºC Sound volume: 41.0 dB(A) Fan speed: 2400 r.p.m Maximum pressure: 20 p.a 100mm (4") Range Additional Data 220-240V - AC. 50Hz . Single phase consuming 14 watts on the 100mm series and 17 watts on the 150mm series. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan should not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor. Electrical Designed for wall or ceiling mounting through 100mm diameter flexible or rigid pipes or Manrose low profile, flat channel ducting systems. Installation 19 technical 20 XF100/XP100/WF100 Regulations on Ventilation (F1). A 163 163 140 163 B 98Ø 98Ø 33 90 C 75 67 98Ø 30 D 30 163 15 163 XF/XP/WF100 Series 85m3/hr, 23 l/s Performance Graph PRODUCT XF100 XF100MH XP100 WF100 Dimensions (mm) 30 G A B Dimensions XF100MH Series 75 98Ø F E 163 I C D A K B 380 102Ø J Dimensions XF100 Series 163 110Ø H PIR activated model which switches on as a person enters the room and runs on after the room is vacated. There is no need to connect to a separate WF100PIR WF100H Complete with pullcord switch WF100T Pullcord model WF100P 100mm (4") WINDOW FANS PIR activated model which switches on as a person enters the room and runs on after the room is vacated. There is no need to connect to a separate As above but with pullcord override switch. Require no switched live As above but with pullcord override switch. Requires no switched live XP100TP (1-20 mins) XP100T Standard model for remote switching XP100HP As above supplied with pullcord switch XP100PIR XP100P life. XP100S with pre-oiled bearings for a long, maintenance- free 100mm (4") EXTRACTOR PAKS with aluminium flexible ducting and wall grille XP100H PIR activated model which switches on as a person enters the room and runs on after the room is vacated. There is no need to connect to a separate XF100PIR As above but with pullcord override switch. Requires no switched live XF100HP XF100H As XF100MH but with Electronic Timer As above but with pullcord switch and neon light XF100MHT XF100MHP 20-90% RH XF100MH As above but with pullcord override switch. Requires no switched live XF100TP As above supplied with pullcord switch XF100T Standard model for remote switching XF100P XF100S and easy cleaning. thermoplastics for strength and durability, aesthetics opposite. second, and is available in the ten options detailed impressive extract rate of 85m3/hr, 23 litres per models for use in bathrooms and toilets. comprehensive range offers a wide selection of 100mm (4") Fan Range Product type 100mm (4") Wall/ceiling Fans Cat. No. Technical Details C D E D I A C J E extended Dimensions WF100 Series outside A B Dimensions XP100 Series F G H B C K inside D 100mm (4") Range Maximum pressure: 20 p.a. Fan speed: 2400 r.p.m. Sound volume: 41.0 dB(A) Maximum operating temperature: 40ºC. Additional Data 220-240V - AC. 50Hz . Single phase consuming 14 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor. Electrical WF100 Series designed for window mounting through a standard 115 155mm Ø hole. XP100 Series designed for through wall fixing, supplied with aluminium flexible ducting and external wall grille. Cut out for XP100 kits (112mm/41/2"). XF100 Series designed for wall mounting (pullcord version wall mounting only) through 100mm (4") diameter flexible or rigid pipes or Manrose low profile, flat channel ducting systems. Installation WF100 Series in outers of 10 measuring 360mm x 210mm x 570mm - weight 9kgs XP100 Series in outers of 10 measuring 380mm x 210mm x 765mm - weight 9kgs XF100MH Series in outers of 10 measuring 572mm x 232mm x 413mm - weight 9kgs XF100 Series in outers of 10 measuring 370mm x 200mm x 560mm - weight 7kgs Packaging 21 technical 22 XF120/XP120/WF120 /hr, 36 litres per second. Building Regulations on Ventilation (F1). easy cleaning. thermoplastics for strength, durability, aesthetics and free life. with pre-oiled bearings fitted for a long, maintenance Power is provided by a single phase induction motor 3 counterparts, yet only 10% larger in surface area. fans are 56% more powerful than their 100mm (4") and medium sized rooms, the 120mm (5") series of possess the latest design technology. toilet fans are quiet in operation, easy to install and in ten options. efficient range of axial flow extractor fans are available 120mm (5") Fan Range A B 182 182 182 118Ø 182 32 182 92 B A B C C D D G 380 118Ø F C D 37 H A Dimensions WF120 outside A B Dimensions XP120 C D E 78 118Ø 112 182 46 118Ø 120Ø 32 182 4-10 Dimensions XF120MH Series A Dimensions XF120 PRODUCT XF120 XF120MH XP120 WF120 Dimensions (mm) F I E 160 glass B C G H 16 J D J I As XF120MH but with electronic time XF120MHT As above with pullcord switch and neon light XF120MHP 20-90% RH XF120MH PIR activated timer for presence detection that will run-on when the room is vacated. Connection to a separate switch is not needed, (timer As above with pullcord override switch. Requires no switched live As above with pullcord override switch. Requires no switched live XF120PIR XP120PIR WF120PIR WF120H XF120HP XP120HP XP120H XF120H XF120TP XP120TP XF120T XP120T WF120T As above supplied with pullcord switch Standard Model for remote switching XF120S XP120S XF120P XP120P WF120P Product type Cat. No. Technical Details XF/XP/WF120 Series 130m3/hr, 36 litres per second Performance Graph 120mm (5") Range Maximum pressure: 35 p.a. Fan speed: 2000 r.p.m. Sound volume: 41.0 dB(A) Maximum operating temperature: 40ºC Additional Data 220-240V - AC. 50Hz . Single phase consuming 15.5 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor. Electrical WF120 Series designed for window mounting through a standard 140mm - 150mm ø hole. XP120 Series designed for through wall fixing and comes complete with aluminium flexible ducting and external wall grille. Cut out for XP120 (140mm/5.5"). XF120 Series designed for wall or ceiling mounting, (pullcord wall-mounting only). Installation WF120 Series in outers of 10 measuring 446mm x 225mm x 550mm - weight 10 kgs XP120 Series in outers of 10 measuring 398mm x 210mm x 825mm - weight 10 kgs XF120MH Series in outers of 10 measuring 760mm x 224mm x 447mm - weight 10 kgs XF120 Series in outers of 10 measuring 400mm x 215mm x 490mm - weight 8 kgs Packaging 23 technical 24 XF150B / XP150B / WF150B /hr, 64 3 Regulations on Ventilation (F1). easy cleaning. thermoplastics for strength, durability, aesthetics and same styling. (4"), 120mm (5") and 150mm (6") fans, all with the Manrose can now offer a complete family of 100mm litres per second. for a long, maintenance-free life. single phase induction motor with pre-oiled bearings shops, offices, restaurants, etc. Power is provided by a style. alternative style and design to the traditional 6" kitchen extractor fans are available in ten options, and are an efficient and easy to install range of 150mm (6") 150mm (6") Fan Range A 203 203 95 203 B 203 150Ø 150Ø 203 C 95 72 180 4-10 B D A B D side elevation C Dimensions XF150B Series A C Dimensions XF150BMH Series PRODUCT XF150B XF150MHB XP150B WF150B 160Ø 23 E 400 F B F extended E outside C D B A D E C glass Dimensions WF150B Series side elevation A Dimensions XP150B Series D 150Ø 203 180 95 PIR activated model with timer and presence detection, timer runs on when the room is vacated. There is no need to connect to a separate Dimensions (mm) Pullcord switch Electronic timer with pullcord override switch and neon light WF150BT As above with pullcord switch and neon light 20 - 90% RH timer runs on when the room is vacated. WF150BP WF150BPIR As above but with pullcord override switch. Requires no switched live As XF150MH but with electronic timer 150mm 6" Window Fans WF150BH As above but with pullcord override switch. Requires no switched live XF150BMHT XF150BMHP XF150BMH XF150BPIR XP150BPIR XF150BHP XP150BHP XF150BH XP150BH XF150BTP XP150BTP XF150BT XP150BT As above supplied with pullcord switch Standard model for remote switching XF150BS XP150BS XF150BP XP150BP Product type Cat. No. Technical Details XF/WF/XP150B Series230m3/hr, 64 litres per second Performance Graph 150mm (6") Range Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m. Sound volume: 40.0 dB(A) Maximum operating temperature: 400C Additional Data 220-240V - AC. 50Hz . Single phase consuming 17 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan should not be accessible to a person using either the shower or the bath and mounted a minimum of 1.8 metres from the floor. Electrical WF150B Series. These fans are designed to be fitted in either a window or wall through a standard 184mm (71/4") hole. A wall fixing kit FK1 (1300) is available which comprises of wall plugs, screws and a 400mm length of 6" diameter aluminium flexible ducting (when fully extended). XP150B Series. These fans are designed for through wall fixing. Complete with aluminium flexible ducting and a wall grille. XF150B Series designed for wall or ceiling mounting (pullcord wall-mounting only). Wall fixing kit is available separately The SVK (1280). Installation XP150B Series in outers of 10 measuring 1070mm x 263mm x 428mm - weight 21kgs WF150B Series in outers of 10 measuring 460mm x 640mm x 240mm - weight 17kgs XF150BMH Series in outers of 10. For packaging dimensions, contact our technical department XF150B Series in outers of 10 measuring 595mm x 245mm x 450mm - weight 11kgs Packaging 25 technical 26 XF/XP/WF100A/120A/150A 3 /hr, 23 Ventilation (F1). and easy cleaning. thermoplastics for strength and durability, aesthetics with pre-oiled bearings for a maintenance-free life. 64 litres per second. 150mm (6"), has a maximum performance of 230m3/hr, 36 litres per second. The largest fan in this range, the powerful with an impressive extract rate of 130m3/hr, bathrooms, toilets and utility rooms are 56% more litres per second, whilst the 120mm units for larger 120mm (5") and 150mm (6"). after the fan is switched on. interior grille which open silently approximately 45 seconds incorporating thermo-activated internal shutters behind the Automatic extractor fan range is available in ten options, all Automatic Shutter Fan Range Product type As above with pullcord override switch Requires no switched live XF100/120ATP/XFA150BTP XP100/120ATP/XPA150BTP WF100/120ATP/1WFA50BTP Electro-mechanical humidity control with on/off B C 39 150Ø 160 XP120A XPA150B 180 133 WFA150B 203 72 59 E 203 182 163 203 182 163 17 155Ø 16 125Ø 15 110Ø 72 59 53 D G 98Ø H D E C extended F Dimensions XF Series A outside A B Dimensions XP Series 380 152Ø 150Ø 380 120Ø 118Ø 380 102Ø F B H 115 112 108 I G J C D inside I 72 59 53 J E K 203 182 163 K PIR activated model with timer for presence detection 1-20 mins) Requires no switched live As above with pullcord override switch. Requires no switched live XP100/120AH/XPA150BH 95% RH Complete with (1-20 mins) (A) XF/XP/WF100A Series 85m3/hr, 23 litres per second (B) XF/XP/WF120A Series 130m3/hr, 36 litres per second (C) XF/XP/WFA150B Series 230m3/hr, 64 litres per second Performance Graph 119 182 WF120A 115 163 WF100A 53 98Ø 37 118Ø 140 XP100A 33 112 115 108 182 118Ø 98Ø XFA150B 203 150Ø XF120A A 163 XF100A PRODUCT Dimensions (mm) XF100/120APIR/XFA150BPIR XP100/120APIR/XPA150BPIR WF100/120APIR/WFA150BPIR XF100/120AHP/XFA150BHP XP100/120AHP/XPA150BHP WF100/120AHP/WFA150BHP XF100/120AH/XFA150BH XF100/120AMHT/XFA150BMHT XP100/120AMHT/XPA150BMHT Electro-mechanical humidity control with on/off switch, WF100/120AMHT/WFA150BMHT XF100/120AMHP/XFA150BMHP XP100/120AMHP/XPA150BMHP As above with pullcord override switch and neon light WF100/120AMHP/WFA150BMHP XF100/120AMH/XFA150BMH XP100/120AMH/XPA150BMH WF100/120AMH/WFA150BMH electronic timer (1-20 mins) XF100/120AT/XFA150BT XP100/120AT/XPA150BT As above supplied with pullcord switch Standard model for remote switching XF100/120AP/XFA150BP XP100/120AP/XPA150BP WF100/120AP/WFA150BP XF100/120A/XFA150BS XP100/120A/XPA150BS WF100/120A/WFA150BS Cat. No. Technical Details A Dimensions WF Series B C 150mm (6") Range Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m. Sound volume: 40.0 dB(A) Maximum operating temperature: 40ºC 120mm (5") Range Maximum pressure: 35 p.a. Fan speed: 2000 r.p.m. Sound volume: 41.0 dB(A) Maximum operating temperature: 40ºC 100mm (4") Range Maximum pressure: 20 p.a. Fan speed: 2400 r.p.m. Sound volume: 41.0 dB(A) Maximum operating temperature: 40ºC Additional Data D 220-240 - AC. 50Hz . Single phase consuming 17 watts on the 100A, 19 watts on the 120A series and 20 watts on the A150B series. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor. Electrical XF100/120A/XFA150B Series designed for wall or ceiling mounting (pullcord wall mounting only). XP100/120A/XPA150B Series designed for through wall fixing, supplied with aluminium flexible ducting and external wall grille. WF100/120A/ WFA150B Series designed for window mounting. Installation XFA150B/XPA150B/WFA150B Series in outers of 10 For packaging dimensions, contact our technical department WF120A Series in outers of 10 measuring 760mm x 224 x 447 - weight 11 kgs XP120A Series in outers of 10 measuring 360mm x 220mm x 982 - weight 11 kgs XF120A Series in outers of 10 measuring 760mm x 224mm x 447mm - weight 10 kgs WF100A Series in outers of 10 measuring 360mm x 210mm x 695mm - weight 9 kgs XF100A Series in outers of 10 measuring 595mm x 365mm x 205mm - weight 9 kgs XP100A Series in outers of 10 measuring 885mm x 360mm x 215mm weight 9 kgs Packaging 27 technical 28 LW100/SELVLW100 80% energy saving Ventilation (F1). easy cleaning. Our new range of Lo-Watt fans are specifically designed to meet the regulations The Building Regulations introduced in 2010 – Domestic dwellings, gives the recommended Watts Per Litre (w/l/s) for each type of fan, to be used in new buildings. New Building Regulations 2010 Domestic thermoplastics for strength and durability, aesthetics and impressive extract rate of 75m3/hr, 21 litres per second. mounting. Lo Watt Humidity Timer Fan Incorporating a 1-20min over run LW100H 3 5 10 15 20 25 30 Volume I/Sec A B Dimensions LW100 0 0 5 Dimensions Transformer SELVLW 100 10 0.5 15 20 25 1 0 Volume m3/hr 20 40 60 80 100 1.5 2 2.5 0 LW100 75m3/hr at 21 litres per C SELVLW100H 30 Lo Watt Humidity Timer Fan Incorporating a 1-20min over run SELVLW100T Performance Graph Lo Watt Standard Fan Lo Watt Timer Fan Incorporating a 1-20min over run SELVLW100S Static pressure mm WG Lo Watt Timer Fan Incorporating a 1-20min over run LW100T Safety Extra Low Voltage (SELV) includes fan and transformer Lo Watt Standard Fan LW100S Static pressure Pa Lo-Watt™ Range Product type Cat. No. Technical Details Product A LW100 163 SELVLW 82 B 98 145 Dimensions (mm) C 97 78 D 30 E 163 Maximum pressure: 20 p.a Fan Speed: 3123 r.p.m Sound volume: 38.0 dB(A) Maximum operating temperature: 45ºC Additional Data 220-240 - AC. 50Hz Single phase Consuming 4.3watts. The LW100 is powered by a brushless motor. All wiring must comply with current IEE regulations. A double pole Isolating switch, having contact separation of at least 3mm in all poles, must be used with a 3amp fuse fitted. The fan must not be accessible to a person using either the shower or the bath (use SELV model) and mounted a minimum of 1.8metres from the floor. Electrical LW100 Series designed for wall mounting only. Through 100mm (4") diameter flexible or rigid pipes. Installation 29 technical 30 LOW VOLTAGE RANGE 100/120/150MM Ventilation (F1), rated to IP44. life. with pre-oiled bearings for a long, maintenance-free and easy cleaning. thermoplastics for strength and durability, aesthetics 110m3/hr 31 litres per second. per second. second and the 150mm 230m3/hr 64 litres litres a second, the 120mm (5") 130m3/hr 36 litres per The extract rate of the 100mm (4") model is 85m3/hr 23 ducting and resistance by grilles. against the high pressures caused by longer lengths of backward curved centrifugal impeller for large airflow shower. and out of the reach of the person using the bath or mounted inside the room where the fan is installed pullcord, humidistat, PIR and versions have to be on the ceiling next to the pullcord switch. Obviously mounted remotely either in the roof space or high motor. The transformer and switching mechanism is model manufactured with a 12V - 50Hz shaded pole use of conventional fans), the 12 Volt fan is a standard shower or bath (where current regulations prevent the 120mm (5") and 150mm (6") and in seven options. (SELV) fans are available in three diameters - 100mm (4"), Safety Extra Low Voltage Bathroom/Shower Extractor Fans 12 Volt SELV Fan Range A Wall or ceiling model * CF200LV 163 182 182 WF100LV XF120LV WF120LV 65 B 65 23 23 150Ø 150Ø 92 118Ø 90 98Ø C 260 95 95 95 95 32 46 30 75 D 185 203 203 203 203 182 78 163 30 E 45 32 163 100 182 F C D G H A B C Dimensions WF150BLV/ WF150ALV B Dimensions CF200LV E D F 90 135 B See page 27 for dimensions on WF120ALV A Dimensions WF120LV See page 27 for dimensions on WF100ALV A Dimensions WF100LV (A) XF/WF100LV 85m3/hr, 23 litres per second (B) XF/WF120LV 130m3/hr, 36 litres per second (C) XF/WF150BLV 230m3/hr, 64 litres per second (D) CF200LV 110m3/hr, 31 litres per second Performance Graphs CF200LV WF150ALV 203 WF150BLV 203 XF150ALV 203 XF150BLV 203 A 163 PRODUCT XF100LV C C Window model/Automatic window model * WF150BLV/WF150ALV B Wall or ceiling model/Automatic wall or ceiling model * XF150BLV/XF150ALV H Window model/Automatic window model WF120LV/WF120ALV G Wall or ceiling model/Automatic wall or ceiling model XF120LV/XF120ALV * Use LT12 Transformer Window model/Automatic window model WF100LV/WF100ALV Dimensions (mm) Product type Wall or ceiling model/Automatic wall or ceiling model Cat. No. XF100LV/XF100ALV Technical Details D D B C B A B C D D C Dimensions XF150BLV/ XF150ALV A Dimensions XF120LV A Dimensions XF100LV D 12 volts AC. - 50Hz. 14W on XF/WF100, 20W on XF/WF120LV, XF/WF150BLV and CF200LV. Supplied by a remote safety isolating transformer - Manrose type T12 series. Electrical F E E CF200LV In outers of 10 measuring 753mm x 283mm x 390mm - weight 12kgs WF150BLV/ALV In outers of 10 measuring 460mm x 640mm x 240mm - weight 17kgs XF150BLV/ALV In outers of 10 measuring 595mm x 245mm x 450mm - weight 11kgs WF120LV/ALV In outers of 10 measuring 446mm x 225mm x 550mm - weight 10kgs XF120LV/ALV In outers of 10 measuring 400mm x 215mm x 490mm - weight 8kgs WF100LV/ALV In outers of 10 measuring 360mm x 210mm x 510mm - weight 9kgs XF100LV/ALV In outers of 10 measuring 370mm x 200mm x 560mm - weight 7kgs Packaging 31 technical 32 T12S/LT12S T12 Series remote Transformer knobs. and easy cleaning. high gloss ABS thermoplastics for strength, durability light and complete with pattress. pullcord light switch. or PIR models) or high-up on the ceiling next to the be mounted in the loft area (not Pullcord, Humidistat of Safety Extra Low Voltage (SELV) transformers can the splash area of the shower or bath, the T12 series PIR Activated model which switches on when the room is entered and runs on when the room is vacated. As above with pullcord override switch. Requires no switched live Outside Zones B 2 0.6m 2 0.6m Shower Zone Diagram Outside Zones 2 1 1 2 Bathroom Zone Diagram A 2 0 2 0 1 2 2 0.6m 2 0.6m Outside Zones 2 2 Outside 2.4m Zones C Window recess Zone 2 Space under bath is Zone 1 if accessible without tool Zone 0 Zone 1 Zone 2 Outside Zones Outside Zones Window recess Zone 2 Space under bath is Zone 1 if accessible without tool Zone 0 Zone 1 Zone 2 Outside Zones Dimensions T12/LT12 Transformer T12PIR/LT12PIR The fan requires no switched live, has no requirement to connect LT models are for use with 150 Range and CF200LV T12HP/LT12HP T12H/LT12H As above with pullcord override switch. Requires no switched live T12TP/LT12TP (1-20mins) T12T/LT12T As above supplied with pullcord switch T12P/LT12P Product type Standard model for remote switching T12S/LT12S Cat. No. Technical Details Zone 2: Extends to 0.60 metres beyond Zone 1 to a height of 2.25 metres above the floor. The exterior of the bath or shower tray to a height of 2.25 metres above the floor. C 66 65 78 Zone 1: B 147 145 145 The interior of the bath or shower tray. A 86 82 82 Zone 0: PRODUCT T12S/T T12P/TP/HP LT12 Dimensions (mm) Construction of transformer in accordance with EN60742. Transformer Input 220-240V - 50Hz . Output 12volt AC. 50Hz 25VA S.E.L.V. (35VA on LT Series) Must be mounted out of reach of the person using the bath or shower. These appliances are double insulated and do not require an earth, but must be connected to the supply through a suitable double pole isolating switch with a minimum contact gap of 3mm on fixed wiring circuits. The protective fuse must not exceed 3A and installation must be supervised by a qualified electrician. See zone diagram for transformer zone rating. Electrical Packed in outers of 10 measuring 313mm x 97mm x 126mm - weight 10kgs. Packaging 33 technical 34 SF100W/120W/150W Regulations on Ventilation (F1), rated to IP44. clips, fixing screws and plugs. external fixed louvre wall grille, self adhesive cable telescopic ducting, one white internal and one grey shutter, a length of 380mm flexible aluminium tube fan with a mounted spring loaded backdraught performance of 230m /hr, 64 litres per second. SF150W, the largest fan in the range, has a maximum SF120W extracts 130m3/hr 36 litres per second. The rate of 85m3/hr 23 litres per second, whilst the larger prevent the installation of conventional fans). splash area of a shower or bath (where regulations the internal wall which enables installation within the mounted inside the wall, 175mm from the face of only 15mm. rooms, the Slimline Wall Fan has a unique profile of Slimline Wall Fan Kit Range Standard 5" model for remote switching SF120W (A) SF100W 85m3/hr, 23 litres per second (B) SF120W 130m3/hr, 36 litres per second (C) SF150W 230m3/hr, 64 litres per second Performance Graph In-line fan Typical Installation Fixed louvre wall grilles Backdraught shutter Standard 6" model for remote switching Standard 4" model for remote switching SF100W SF150W Product type Cat. No. Technical Details SF100/120/150W with flexible aluminium ducting SF100W SF120W SF150W See page 43. (ID100/120/150 series) Dimensions (mm) 150mm (6") Range Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m. Sound volume: 40.0 dB(A) Maximum operating temperature: 40ºC 120mm (5") Range Maximum pressure: 35 p.a. Fan speed: 2000 r.p.m. Sound volume: 41.0 dB(A) Maximum operating temperature: 40ºC 100mm (4") Range Maximum pressure: 20 p.a. Fan speed: 2400 r.p.m. Sound volume: 41.0 dB(A) Maximum operating temperature: 40ºC Additional Data 220-240V - AC. 50Hz . Single phase consuming 14W on SF100W, 15.5W on SF120W and 20W on SF150W. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan should not be accessible to a person using either the shower or bath, and mounted a minimum of 1.8 metres from the floor. Electrical Designed for mounting in-line in walls and discharged through the flexible aluminium ducting provided. Installation SF150W In outers of 10. For packaging dimensions, contact our technical department SF120W In outers of 10 measuring 510mm x 234mm x 867mm - weight 13kgs SF100W In outers of 10 measuring 605mm x 318mm x 745mm - weight 12kgs Packaging 35 technical 36 SL/SLK 100MM 120MM & 150MM Showerlite Range ducting runs. ducting, external wall grille, fixing screws, plugs and straps. Showerlite unit, transformer, one length of PVC flexible supplied complete with fan (available with or without timer), They are also available in a blister fan kit pack. Each pack is packaging or in blister packs with or without transformer. providing a rich warm glow of soft light. Manrose Showerlite will enhance any shower or bathroom centrifugal fans. range of in-line axial fans or the CFD/MAN range of in-line and 150mm (6") in-line system such as the Manrose SF/ID isolating transformer. Showerlite fan kit, standard model chrome fitting Showerlite fan kit, standard model brass fitting SL-120SC SL-120SB Showerlite fan kit, timer model brass fitting Showerlite fan kit, timer model chrome fitting Showerlite fan kit, timer model brass fitting SL-150TW SL-150TC SL-150TB PRODUCT SL-W/B/C SL120 SL150 A 140Ø 170Ø 200Ø B 74 74 74 C 98 118 148 Showerlite centrifugal fan kit, timer model chrome fitting SLCFDTC Dimensions (mm) Showerlite centrifugal fan kit, timer model white fitting Showerlite centrifugal fan kit, timer model brass fitting SLCFDSC SLCFDTB Showerlite centrifugal fan kit, standard model chrome fitting SLCFDSB SLCFDTW Showerlite centrifugal fan kit, standard model white fitting Showerlite centrifugal fan kit, standard model brass fitting SLCFDSW Centrifugal Packs Boxed Packaging Showerlite fan kit, standard model brass fitting Showerlite fan kit, timer model white fitting SL-150SB Showerlite fan kit, standard model chrome fitting SL-150SC Showerlite fan kit, standard model white fitting SL-120TB SL-150SW Showerlite fan kit, timer model chrome fitting SL-120TC Showerlite fan kit, timer model white fitting Showerlite fan kit, standard model white fitting SL-120SW SL-120TW Showerlite fan kit, timer model chrome fitting SLKTC Showerlite fan kit, timer model white fitting Showerlite fan kit, timer model brass fitting SLKTB Showerlite fan kit, standard model chrome fitting SLKTW Showerlite fan kit, standard model brass fitting Showerlite fan kit, standard model white fitting SLKSC SLKSB SLKSW Showerlite with transformer chrome fitting SL-CTB Showerlite In-Line Axial Extractor Packs Blister Packaging Showerlite with transformer brass fitting Showerlite chrome fitting Showerlite brass fitting SL-BB SL-CB Showerlite with transformer white fitting SL-WTB SL-BTB Showerlite white fitting SL-WB Transformer T1250W shower or bath and is powered by a S.E.L.V. remote safety and 150mm (6") versions. and bathrooms. Now available in 100mm (4"), 120mm (5") is incorporated into a circular diffuser, suitable for showers Showerlite chrome fitting Showerlite Single Blister Packs Showerlite brass fitting SL-C Showerlite white fitting Product type SL-B SL-W Boxed Cartons Cat. No. Technical Details A Dimensions Typical Installation B C All plastic components are moulded in high temperature VO rated thermoplastics. Construction 12 volt 35W dichroic 5.3 sealed lamp. Powered by a transformer T1250W. Input, AC. Output, 12 volt AC. 50 VA. Electrical Designed to be ceiling mounted through 102mm (4") diameter flexible ducting or rigid pipes. Installation Boxed in outers of 10. For packaging dimensions, contact our technical department. Packaging 37 technical 38 MAN50/MAN50SF/MAN50SLK 175mm Ø100mm MAN50 Maximum pressure 120p.a. Additional Data All wiring must comply with the current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. ducting and resistance by grilles. Showerlite fitting and transformer. grilles together with a chrome metres of PVC ducting and wall centrifugal in-line fan unit, 6 which comprises of the MAN50 and wall grilles. fan unit, 6 metres of PVC ducting caused by longer lengths of against the high pressures maintenance-free life. of the MAN50 centrifugal in-line impellers for a large airflow backward curved centrifugal with pre-oiled bearings for a long, shower rooms and utility rooms. Regulations on Ventilation (F1). a single phase induction motor including bathrooms, toilets, a wide range of applications comply with the 2006 Building litres per second. mounting bracket. Designed to have extract rates of 110m3/hr 31 unobtrusive, the MAN50 units and durability, aesthetics and easy backdraughts. ABS thermoplastics for strength discharge spigot to prevent cleaning. manufactured using high impact non-return flap is built into the MAN50 Range 110m3/hr, 31 litres per second Maximum operating temperature: 40ºC Sound volume: 45.0dB(A) Performance Graph 180mm 220-240V - AC. 50Hz . Single phase consuming 20W on the MAN50 Electrical For packaging dimensions please contact our technical department. Fan speed: 1400 r.p.m. Timer model in-line fan kit (100mmØ) MAN50TSFK MAN50 Series in outers of 5 Packaging ceilings, A spring operated, Timer model with bracket MAN50T MAN50TSLKC Timer model in-line Showerlite fan kit (100mmØ) Chrome Standard model with bracket MAN50S designed for use with suspended systems. to cover most in-line ducting MAN50 in-line fan has been commercial applications, the ventilation accessories available wide range of domestic and Man50 In-line Centrifugal Fan Range Product type Cat. No. Technical Details 39 technical 40 PRO SHOWERLITE for easy fan installation in the roof. The first in-shower ventilation kit incorporates seven 3 A bracket is also included in your house. 1 2006 building regulations. bathroom or any other area 7 5 4 4 2 equipment within one kit. 4 6 bathroom. 4 of soft light to enhance any provides a rich warm glow waterproof protection. It is a sealed unit for total IP attractive chrome finish and The Showerlite fan has an to reduce to 100mm/4". a built in extended reducer, 120mm/5" Showerlite with An attractive powerful 50lps, which exceeds the extend the ventilation in your 2 capable of extracting 180hr powerful way, to totally different pieces of ventilation centrifugal fan. This is provide an effective and A powerful high performance In-line 1 The kit includes: everything you require to so much more. It includes Showerlite fan kit gives you The complete Professional 6 5 4 3 7 for your total ventilation. showerlite.The complete kit to power the 12 volt (SELV) transformer, A safety extra low voltage Showerlite. fan, internal grille and ducting to the in-line which connects the PVC A PVC T-Piece connector, install guide). soffit. (see installation for which fits into the external the egg crate wall grille, in-line fan extracts through An external wall grille; the size room. adapt the installation in any long length enables you to flexible PVC ducting. This 10 metres of 100mm/4" unobtrusively into any room. unique design, and will fit white grille, which has a this is a circular internal One additional inlet, Professional Showerlite Fan Kit Boxed in outers of one. Please contact our technical department for further details. A B 3 1 B Ø135mm Ø140mm Ø100mm Ø100mm Ø165mm 272mm ØA C B ØA 74mm 140mm 33mm 250mm 10mm 136mm B C D dØ ØD C A B 5 B 4 C A 2a 100mm 100mm dØ C A 120mm Ø250mm D B 2 117mm 50mm 15mm 100mm E Ød 72mm E VENTILATES POWERFULLY & ILLUMINATES SAFELY ØA 1 2 2a 3 4 5 PRODUCT Dimensions Catalogue Number PROCFSLKC In-Line Centrifugal Fan Performance: 180m3h 50lps Fan speed: 2500 rpm Max Operating Temperature: 60ºC Sound Level: 43.0 dB(A) Weight: 2kg Additional Data In-Line Centrifugal Fan 4 pole single phase induction motor with ball bearings fitted for a long, maintenancefree life and protected by a thermo-auto resetting cut-out approved totally enclosed for protection against dirt and dust. Motors are continually rated. Motor In-Line Centrifugal Fan Strong impact light grey plastic casing. Showerlite Fan All plastic components are moulded in high temperature VO rated thermoplastics. Construction In-Line Centrifugal Fan Induct Fans suitable for in-line systems and designed for use with suspended ceiling systems. Showerlite Fan Designed to fit through a 120mm/5" diameter hole with an incorporated reducer to fit 100/4" PVC ducting. Installation Electronic transformer for LV-Halogen lamps. Input: 230V-50-60Hz Output: 12V 20-60W Transformer 220-240V- AC. 50Hz Single phase consuming 32 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. In-Line Centrifugal Fan Showerlite Fan 12 volt 35W dichroic 5.3 sealed lamp. Powered by a transformer T1250W. Input, AC output, 12 volt AC. 50VA dimmable. Electrical Packaging 1 2 3 4 5 6 7 In-line centrifugal duct fan with mounting bracket 1 x 120mm/5" Showerlite unit with chrome fitting & fixed reducer to 100mm/4" 1 x Circular Internal White Grille 10 metres of 100mm/4" PVC Flexible Ducting 1 x Egg Crate External Wall Grille 1 x PVC T-Piece Connector 1 x Low Volt Transformer The Professional Showerlite kit is supplied complete with: Technical Details 41 41 technical 42 SF100/120/150 ID100/120/150 Ventilation (F1). 2006 Building Regulations on maintenance-free life. litres per second. pre-oiled bearings for a long, performance of 230m3/hr, 64 phase induction motor with ID150 Tube Fan, with a top Also new to the range is the 130m3/hr 36 litres per second. performs with an impressive cleaning. durability, aesthetics and easy using high impact ABS per second, whilst the SF/ID120 thermoplastics for strength and SF/ID100 is 85m3/hr 23 litres operation, the extract rate of the where a long run of ducting is used. their 100mm counterparts. and are 56% more powerful than suitable for boosting another fan larger shower or bathroom areas, comprises a fan unit only and is engineered for the ventilation of series of in-line fans have been screws, plugs and straps to secure the duct to the grilles. one external wall grille, fixing mounted remotely. ducting, one internal (white) and shock in wet areas as the fan is remove any risk of an electric unit, one length of PVC flexible supplied complete with a fan 4") range of in-line extractor fans rooms, the SF/ID 100 (100mm the SF100/120/150 fan kits are of bathrooms, toilets and shower Shower/In-line Fan Range (1-20 mins) SF100/120/150T B B C A Dimensions ID100/120/150 Series A Dimensions SF100/120/150 Circular and Square Grille PRODUCT A ID100 98Ø ID120 116Ø ID150 148Ø ID100S 130 ID120S 150 ID150S 187 SF100S/T Up to 3m SF120S/T Up to 4m SF150S/T Up to 5m Dimensions (mm) A B 90 99 110 155 155 153 140 160 180 C 100 118 150 90 99 109 140 160 180 E 15 16 15 F D G Internal grey grille H 10 10 10 H I I J J 50 98Ø 50 116Ø 50 148Ø External grey grille Dimensions ID100S/120S/150S Series with Bracket 140 140 140 G Showerfan screwed E C 27 27 27 33 37 35 Flexible Ducting 100Ø 118Ø 150Ø 100Ø 125Ø 150Ø D Performance may vary depending on the length of ducting used SF/ID150 Up to 230m3/hr, 64 litres per second SF/ID120 Up to 130m3/hr, 36 litres per second SF/ID100 Up to 85m3/hr, 23 litres per second Performance (1-20 mins) ID100/120/150T Standard model for remote switching with bracket ID100/120/150S Standard model (tube fan) for remote switching ID100/120/150 ID In-line fans Standard model for remote switching SF100/120/150S In-line fan kits with PVC duct and wall grilles SF Product type Cat. No. Technical Details 150mm (6") Range Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m. Sound volume: 40.0 dB(A) Maximum operating temperature: 40ºC 120mm (5") Range Maximum pressure: 35 p.a. Fan speed: 2000 r.p.m. Sound volume: 41.0 dB(A) 100mm (4") Range Maximum pressure: 20 p.a. Fan speed: 2400 r.p.m. Sound volume: 41.0 dB(A) Maximum operating temperature: 40ºC Additional Data 220-240V - AC. 50Hz . Single phase consuming 14W on ID100, 15.5W on ID120 and 20W on ID150. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. Electrical The shower fan is easy to install in the average loft/ceiling recess as after the hole has been cut in the ceiling of the shower/room, all other work is continued outside the living area. Installation ID150/S/T In outers of 10 contact our technical department for packaging dimensions ID120/S/T In outers of 10 measuring 328mm x 179mm x 567mm - weight 7kgs ID100/S/T In outers of 10 measuring 282mm x 176mm x 490mm - weight 6kgs ID150 In outers of 10. For packaging dimensions, contact our technical department ID120 In outers of 10 measuring 264mm x 144mm x 567mm - weight 5kgs ID100 In outers of 10 measuring 220mm x 125mm x 490mm - weight 4kgs SF150 In outers of 5 measuring 440mm x 393mm x 1083mm. Volume 1.873 SF120 In outers of 10 measuring 620mm x 396mm x 917mm - weight 17kgs SF100 In outers of 10 measuring 515mm x 350mm x 820mm - weight 16kgs Packaging 43 technical 44 SF150A/ID150A 152mmØ. ducting supplied is one 5m length Ventilation (F1). and the fan unit, whilst the PVC maintenance-free life. pre-oiled bearings for a long, 2006 Building Regulations on phase induction motor with secure the duct onto the grilles screws, plugs and straps to supplied complete with fixing or as In-line fan kits, which are ducting used. depending on the length of and external grilles. The flexible durability, including the internal reinforced with steel wire. ducting is made from PVC to 220m3/hr 62 litres per second, has a powerful extract rate of up thermoplastics for strength and using high impact ABS remotely. removed as the fan is mounted make installation simple. has easy to follow instructions to with water. there is a possibility of contact and sports facilities, the SF150 bars and meeting rooms, schools and bathrooms, or any where ventilation of larger shower rooms rooms with showers, restaurants, have been designed for the safe 150mm (6") In-line Fan Kit Range Product type A B D C B C Typical Installations Internal white grille Flexible ducting SF150/ID150 Up to 220m3/hr, 62 litres per second Maximum Fan performance stated, this can vary depending on the length of ducting used Performance A Dimensions SF150/ID150 Series Dimensions ID150 Series Standard model for remote switching ID150AT ID150A automatic in-line shutters SF150AT Standard model for remote switching SF150A In-line fan kits with PVC duct and wall grilles incorporating automatic in-line shutters Cat. No. Technical Details B 180 180 C 180 180 D Up to 5m External grey grille The 150mm (6”) in-line fan attached to the floor above the suspended ceiling PRODUCT A SF150A 152Ø ID150A 152Ø Dimensions (mm) 150mm (6") Range Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m. Sound volume: 40.0 dB(A) Maximum operating temperature: 40ºC Additional Data 220-240V - AC. 50Hz . Single phase consuming 20W on the SF150A automatic models. These fans are double insulated and do not require an earth. All wiring must comply with the current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. Electrical The 150mm shower fan is easy to install in the average loft/ceiling recess as, after the hole has been cut in the ceiling of the shower/room, all other work is continued outside the living area. Installation ID150 In outers of 10 measuring 755mm x 229mm x 428mm volume 0.07m3 SF150 In outers of 5 measuring 440mm x 393mm x 1083mm volume 1.87m3 Packaging 45 technical 46 CF100/CF200/CF400 easy cleaning. Regulations on Ventilation (F1). fibre filter. fans are also supplied with a 11mm thick washable for a maintenance free life of over 40,000 hours. These external rotor motors which incorporate ball bearings long, maintenance-free life. phase induction motor with pre-oiled bearings for a and thermoplastics for strength and durability, aesthetics second. has a maximum performance of 230m3/hr, 64 litres per per second. The largest fan in the range, the CF400 CF200 range have an extract rate of 110m /hr 31 litres 3 has an extract rate of 90m3/hr 20 litres per second, the backdraughts. non-return flap into the discharge spigot to stop resistance by grilles. pressures caused by long lengths of ducting and units will give maximum performance even against restaurants, hotels and offices. for kitchens and commercial applications, such as cloakrooms, utility rooms, and the CF400 is designed CF100/200 ranges are designed for bathrooms, toilets, yet very quiet and vibration free ventilation. The the latest technology to provide extremely powerful, Centrifugal Fan Range Electronic humidity control with pullcord override switch Requires no switched live As above with pullcord override switch. Requires no switched live As above supplied with pullcord switch D D 90 260 350 B E 163 45 45 D 98Ø 98Ø F C 90 153 G G H 110m3/hr, 31 litres per second C 65 185 265 A D Performance Graph CF200 B 98Ø 65 60 A 90m3/hr, 25 litres per second A 163 65 70 E F B Dimensions CF400 Series G H E Dimensions CF200 Series Performance Graph CF100 PRODUCT CF100 CF200 CF400 Dimensions (mm) B C A Dimensions CF100 Series C 135 198 H F E CF100PIR CF200PIR run on when room is vacated (1-20 mins). Requires no switched live CF400PIR CF200HP CF400HP CF100H CF200H CF400H CF100TP CF200TP CF400TP CF100T CF200T CF400T CF100P CF200P CF400P 230m3/hr, 64 litres per second Performance Graph CF400 CF400 Maximum pressure: 300 p.a. Fan speed: 2335 r.p.m. Sound volume: 58.0 dB(A) Maximum operating temperature: 89ºC CF200 Maximum pressure: 120 p.a. Fan speed: 1400 r.p.m. Sound volume: 45.0 dB(A) CF100 Maximum pressure: 80 p.a. Fan speed: 1600 r.p.m. Sound volume: 42.0 dB(A) Additional Data 220-240V - AC. 50Hz single phase consuming 17W on the CF100 range, 17W on the CF200 range and 45W on the CF400 range. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3amp fuse fitted. The fan should not be accessible to a person using either the shower or bath and mounted to a minimum of 1.8 metres from the floor. Electrical Designed to be mounted on walls or ceilings and discharged through a 100mm (4") standard rigid or flexible duct, and are also suitable for use with flat duct channel systems. Comprehensive wiring and installation instructions are included with each fan. Installation CF400 Series in outers of 5 measuring 290mm x 400mm x 920mm - weight 14kgs CF200 Series in outers of 10 measuring 753mm x 283mm x 390mm - weight 12kgs CF100 Series in outers of 10 measuring 340mm x 175mm x 835mm - weight 11kgs CF100S CF200S CF400S Standard model for remote switching Packaging Cat. No. Product type Technical Details 47 technical 48 M200S /h (15l/s) to 3 comply with the Building Regulations (Document F) versions. Available as a wall model with the addition of a wall fitting kit. via rigid, flexible or flat ducting. Designed for wall or ceilings mounting and discharging vertical ducted system. in 2 positions allowing for rear exit or connecting to a impeller assembly. The rear spigot can be mounted due to the unique cassette design of the motor and M200 is designed for surface or flush mounting for ducted ventilation of internal bathrooms and WC’s. The M200 range of centrifugal bathroom fans are designed M200 Centrifugal Bathroom Fan Single speed fan with integral back draught shutters Integral requirements of Part F Building Regulations 2006, for installed performance Single speed fan with integral back draught shutters. Integral Building Regulations 2006, for installed performance Electronic Humidity control with pullcord over ride switch requires no switched live. M200T M200H M200HP Flush Fitting C Dimensions E 70m3/hr 20 litres per second Surface Mount D Single speed fan with integral back draught shutters. Pullcord operation. Meets the requirements of Part F Building Regulations 2006, for installed performance M200P Performance Graph M200 Single speed fan with integral back draught shutters. Light or remote switch operation. Meets the requirements of Part F Building Regulations 2006, for installed performance M200S B Product type Cat. No. Technical Details A PRODUCT A B M200 210 265 Dimensions (mm) C 100 D 90 M200 Maximum pressure: Sound volume: 36.0 dB(A) Maximum operating temperature: 40ºC Additional Data E 17 220-240V - AC. 50Hz single phase consuming 11W on the M200 range, These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3amp fuse fitted. The fan should not be accessible to a person using either the shower or bath and mounted to a minimum of 1.8 metres from the floor. Electrical Designed to be mounted on walls or ceilings and discharged through a 100mm (4") standard rigid or flexible duct, and are also suitable for use with flat duct channel systems. Comprehensive wiring and installation instructions are included with each fan. Installation M200 Series in outers of 10 measuring 753mm x 283mm x 390mm – weight 12kgs Packaging 49 technical 50 XF150/WF150 Regulations on Ventilation (F1). life. with pre-oiled bearings for a long, maintenance-free and easy cleaning. thermoplastics for strength and durability, aesthetics WF150 range is suitable for window mounting. rooms, restaurants, hotels, offices and shops. The commercial applications including kitchens, utility XP150 range is ideally suited to use in domestic and second on the WF150. for the XF/XP version and 220m3/hr 62 litres per powerful extract rate of 230m3/hr 64 litres per second has been designed for simple installation, and has a be wall, ceiling or window mounted. (6") axial flow kitchen fans are quiet, efficient and can 6" Wall and Window Fan Range Product type Standard model A B C D D A A B E C F D PRODUCT A B C D E F XF150 203 203 95 150Ø XF150A 203 203 95 150Ø XP150 95 150Ø 400 160Ø 180 180 WF150 203 203 95 23 Dimensions (mm) C D Dimensions XP150 Series B Dimensions XF150A Series (A) XF/XP/150 Series 230m3/hr, 64 litres per second (B) WF150 Series 220m3/hr, 62 litres per second Performance Graphs A SIDE ELEVATION THROUGH GLASS Dimensions WF150 Series B C Humidity control complete with pullcord Timer model complete with pullcord Pullcord model Standard model Dimensions XF150 Series WF150AH WF150AT WF150AP WF150A Automatic model with internal shutters Timer model complete with pullcord Humidity control complete with pullcord WF150H Pullcord model WF150T WF150P WF150 Electronic humidity control with pullcord override switch Requires no switched live WINDOW FANS - Basic model with fixed grilles XF150AHP/XP150AHP XF150AH/XP150AH timer (1-20 mins) XF150AT/XP150AT Standard model for remote switching As above supplied with pullcord switch XF150AP/XP150AP XF150A/XP150A Electronic humidity control with pullcord override switch Requires no switched live WALL/CEILING FANS AND PAKS - Automatic model with internal shutters XF150HP/XP150HP XF150H/XP150H timer (1-20 mins) As above with pullcord switch XF150T/XP150T Standard model for remote switching XF150P/XP150P XF150/XP150 WALL/CEILING FANS AND PAKS - Base model with fixed internal grille Cat. No. Technical Details Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m. Sound volume: 40.0 dB(A) Maximum operating temperature: 40ºC Additional Data 220-240V - AC. 50Hz . Single phase consuming 17W on the 150 series and 20W on the 150A automatic models. These fans are double insulated and do not require an earth. All wiring must comply with the current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan should not be accessible to a person using either the shower or bath and mounted a minimum of 1.8m from the floor. Electrical WF150/WF150A this series has been designed for window or wall fixing through a standard 184mm (71/4 wall fixing, please use the FK1 wall vent kit Cat No. 1300. There are two variations in the range, the base model with fixed louvres for additional trickle flow ventilation and the automatic model incorporates thermoactivated internal shutters (except the pullcord operated model WF150AP). XP150/150A This series has been designed for through wall fixing and is supplied complete with aluminium flexible ducting and wall grille. The XP150/150A series of 150mm (6") extractor fans can be wall mounted, and there are two models available in this range. The XP150 model has a fixed louvre internal grille, whilst the automatic model the XP150A, has thermoactivated internal shutters which open 45 seconds after the fan has been switched on (except the manual pullcord operated model XP150AP). The XF150/150A series of 150mm (6") extractor fans can be wall or ceiling mounted (not pullcord models), and there are two models available in this range. The XF150 model has a fixed louvre internal grille, whilst the automatic model the XF150A, has thermo-activated internal shutters which open 45 seconds after the fan has been switched on (except the manual pullcord operated model XF150AP). Installation WF150 In outers of 10 measuring 460mm x 640mm x 240mm - weight 17kgs XP150 In outers of 10 measuring 1070mm x 263mm x 428mm - weight 21kgs XF150 In outers of 10 measuring 595mm x 245mm x 450mm - weight 11kgs Packaging 51 technical