Ventilation Manrose Fans Domestic

Transcription

Ventilation Manrose Fans Domestic
14
FLAT100SFLAT150S
Flat Fan Range
฀
฀
฀ ฀
3
/h (15l/s)-
฀
฀
฀฀฀
฀฀฀
฀ ฀
฀฀฀
฀
฀
฀
฀
฀
฀
฀
with the Building Regulations (Document F).
bathrooms and 216m3/h (60l/s) - kitchens to comply
฀฀฀
fixing kit.
Suitable for wall or panel mounting using the appropriate
cloakrooms and kitchens. Slim profile only 15mm.
100mm and 150mm panel axial fans for bathrooms,
Product type
Single speed axial fan with electronic over-run timer – up to 30 mins
and integral backdraught shutters
FLAT100T
A
Ø C
D
B
Single speed axial fan with integral backdraught shutters for remote or
light switch operation
Performance Graph
A
Dimensions
FLAT150S
Kitchen & Utility room Fans
Single speed axial fan with integral backdraught shutters for remote or
light switch operation
FLAT100S
Bathroom & toilet Fans
Cat. No.
Technical Details
PRODUCT
FLAT100S
FLAT100T
FLAT150S
FLAT150T
A
159
159
225
225
Dimensions (mm)
B
15
15
15
15
C
98
98
144
144
D
70
70
93
93
150mm (6") Range
Maximum pressure: 50 p.a.
Sound volume: 45.0 dB(A)
Maximum operating temperature: 40ºC
100mm (4") Range
Maximum pressure: 20 p.a.
Sound volume: 38.0 dB(A)
Maximum operating temperature: 40ºC
Additional Data
220-240V - AC. 50Hz . Single phase
consuming 14 watts on the 100 series
and 16 watts on the 150 series. These
fans are double insulated and do not
require an earth. All wiring must comply
with current IEE regulations. A double
pole isolating switch, having a contact
separation of at least 3mm in all poles,
must be used with a 3 amp fuse fitted.
The fan must not be accessible to a
person using either the shower or bath
and mounted a minimum of 1.8 metres
from the floor.
Electrical
Flat Fan series packed in outers of 10.
Contact our technical department for
packaging dimensions
Packaging
15
technical
16
LP100/LP120/LP150
Lo Profile Range
฀
฀ ฀
฀฀฀
฀฀฀
฀
฀
฀
฀
฀ ฀
฀ ฀
฀
฀
฀ ฀
฀
฀
฀
3
฀
฀
฀
฀
฀
3
฀
฀
฀
฀
฀ ฀
฀
/hr or 36 litres per second - 120mm (5") 230m3/
฀
฀
hr or 64 litres per second - 150mm (6").
฀฀฀
rates of 85m /hr or 23 litres per
฀฀฀
Circular Front Covers.
฀฀฀
ventilation (F1).
to comply with the 2006 building regulations on
฀฀฀
฀
฀฀฀
room.
flush fitting allows the fan to blend into the decor of the
enables it to fit unobtrusively into any wall or ceiling. Its
The Manrose Lo Profile fan has a unique design which
Product type
฀
LP100/120/150STC฀ ฀
฀
฀
฀
฀
฀
electronic timer (1-20 mins) - Chrome
฀
฀
฀
฀
฀
C
B
A
A
A
D
Dimensions
LP100/120/150S
Series Square
Grille
Dimensions
LP100/120/150 Series
For the Circular &
Square Grille
(A) LP100 Series 85m /hr, 23 litres per second
(B) LP120 Series 130m3/hr, 36 litres per second
(C) LP150 Series 230m3/hr, 64 litres per second
3
Performance Graph
฀
฀
฀
฀
฀
฀
Dimensions
LP100/120/150C
Series Circular
Grille
A
LP100/120/150CLVC Low Profile STD (low voltage) - Chrome
LP100/120/150CLVB Low Profile STD (low voltage) - Brass
LP100/120/150CLVW Low Profile STD (low voltage) - White
LP100/120/150CTC฀ ฀
฀
฀
฀
฀
฀
electronic timer (1-20 mins) - Chrome
LP100/120/150CTB฀ ฀
฀
฀
฀
฀
electronic timer (1-20 mins) - Brass
LP100/120/150CTW฀ ฀
฀
฀
฀
฀
electronic timer (1-20 mins) - White
LP100/120/150CSC Low Profile Standard model for remote switching - Chrome
LP100/120/150CSB Low Profile Standard model for remote switching - Brass
LP100/120/150CSW Low Profile Standard model for remote switching - White
CIRCULAR Front Cover
LP100/120/150SLVC Low Profile STD (low voltage) - Chrome
LP100/120/150SLVB Low Profile STD (low voltage) - Brass
LP100/120/150SLVW Low Profile STD (low voltage) - White
฀
฀
LP100/120/150STB฀ ฀
฀
฀
฀
฀
electronic timer (1-20 mins) - Brass
฀
฀
Low Profile Standard model for remote switching - Chrome
LP100/120/150SSC
LP100/120/150STW฀ ฀
฀
฀
฀
฀
electronic timer (1-20 mins) - White
Low Profile Standard model for remote switching - Brass
LP100/120/150SSB
LP100/120/150SSW Low Profile Standard model for remote switching - White
Square Front Cover
Cat. No.
Technical Details
PRODUCT
A
LP100S
140
LP100C 140Ø
LP120S
161
LP120C 165Ø
LP150S
191
LP150C 198Ø
B
100
100
122
122
122
122
Dimensions (mm)
C
10
10
10
10
10
10
D
98Ø
98Ø
118Ø
118Ø
150Ø
150Ø
150mm (6") Range
Maximum pressure: 50 p.a.
Fan speed: 2400 r.p.m.
Sound volume: 40.0 dB(A)
Maximum operating temperature: 40ºC
120mm (5") Range
Maximum pressure: 35 p.a.
Fan speed: 2000 r.p.m.
Sound volume: 41.0 dB(A)
Maximum operating temperature: 40ºC
100mm (4") Range
Maximum pressure: 20 p.a.
Fan speed: 2400 r.p.m.
Sound volume: 41.0 dB(A)
Maximum operating temperature: 40ºC
Additional Data
220-240V - AC. 50Hz
. Single phase
consuming 14 watts (100mm) and 17
watts (120/150mm). These fans are
double insulated and do not require an
earth. All wiring must comply with current
IEE regulations. A double pole isolating
switch, having a contact separation of
at least 3mm in all poles, must be used
with a 3 amp fuse fitted. The fan must
not be accessible to a person using
either the shower or bath and mounted a
minimum of 1.8 metres from the floor.
Electrical
Designed for wall or ceiling mounting
through either 100mm(4"), 120mm(5"),
150mm(6") diameter flexible or rigid
pipes or Manrose low profile, flat
channel ducting systems.
Installation
In outers of 10, for packaging
dimensions contact our technical
department.
Packaging
17
technical
18
Rtdeco100 & Rtdeco150
Rtdeco Range
฀ ฀
฀฀฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀฀฀
฀
฀
rates of 75m3
฀฀฀
ventilation (F1).
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀ ฀
฀
to comply with the 2006 building regulations on
฀฀฀
฀
฀฀฀
฀
3
/hr
฀
As Above With Aluminium Front Cover
DECO150HC
5
0
0.5
0
Rtdeco150 Range 220m3/hr, 62 litres per second
Performance Graph
10
1
10 15 20 25 30
Volume I/Sec
15
5
20
2
1.5
0
25
30
2.5
3
0
Volume m3/hr
20 40 60 80 100
Rtdeco100 Range 75m³/hr, 20 litres per second
Performance Graph
As Above With Aluminium Front Cover
Humidity Fan With Integral
DECO150HW
With Integral Timer
DECO150TC
DECO150TW
Static pressure mm WG
฀
Static pressure Pa
฀฀฀
Standard Fan
As Above With Aluminium Front Cover
DECO150SC
As Above With Aluminium Front Cover
DECO100HC
DECO150SW
As Above With Aluminium Front Cover
Humidity Fan With Integral Timer
DECO100HW
With Integral Timer
DECO100TW
DECO100TC
Standard Fan
As Above With Aluminium Front Cover
DECO100SC
Product type
DECO100SW
Cat. No.
Technical Details
Product
Rtdeco100
Rtdeco150
A
140
191
Dimensions (mm)
B
105
122
C
30
10
D
98
150Ø
Maximum operating temperature: 40ºC
Sound volume: 40.0 dB(A)
Fan speed: 2400 r.p.m
Maximum pressure: 50 p.a
150mm (6") Range
Maximum operating temperature: 40ºC
Sound volume: 41.0 dB(A)
Fan speed: 2400 r.p.m
Maximum pressure: 20 p.a
100mm (4") Range
Additional Data
220-240V - AC. 50Hz
. Single phase
consuming 14 watts on the 100mm
series and 17 watts on the 150mm
series. These fans are double insulated
and do not require an earth. All wiring
must comply with current IEE regulations.
A double pole isolating switch, having a
contact separation of at least 3mm in all
poles, must be used with a 3 amp fuse
fitted. The fan should not be accessible
to a person using either the shower or
bath and mounted a minimum of 1.8
metres from the floor.
Electrical
Designed for wall or ceiling mounting
through 100mm diameter flexible or
rigid pipes or Manrose low profile, flat
channel ducting systems.
Installation
19
technical
20
XF100/XP100/WF100
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
Regulations on Ventilation (F1).
฀฀฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
A
163
163
140
163
B
98Ø
98Ø
33
90
฀
C
75
67
98Ø
30
฀
฀
D
30
163
15
163
XF/XP/WF100 Series 85m3/hr, 23 l/s
Performance Graph
PRODUCT
XF100
XF100MH
XP100
WF100
Dimensions (mm)
฀
30
G
฀
A
B
Dimensions
XF100MH Series
75
98Ø
฀
F
฀
E
163
฀ ฀
฀
I
C
D
A
K
B
380 102Ø
J
Dimensions
XF100 Series
163 110Ø
H
฀
PIR activated model which switches on as a person enters the room and
runs on after the room is vacated. There is no need to connect to a separate
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
WF100PIR
฀
฀
฀
฀
WF100H฀฀
฀
฀
฀
฀
฀
Complete with pullcord switch
WF100T฀
฀
Pullcord model
WF100P
100mm (4") WINDOW FANS
PIR activated model which switches on as a person enters the room and
runs on after the room is vacated. There is no need to connect to a separate
฀
฀
฀
฀
฀
฀
฀ ฀
฀
As above but with pullcord override switch. Require no switched live
฀
As above but with pullcord override switch. Requires no switched live
฀
฀
฀
XP100TP
฀
฀
฀
฀
฀
(1-20 mins)
XP100T฀
฀
Standard model for remote switching
XP100HP
฀
฀
฀
As above supplied with pullcord switch
XP100PIR
฀ ฀
฀
XP100P
life.
฀
฀
฀
฀
XP100S
with pre-oiled bearings for a long, maintenance- free
฀ ฀
฀
฀
100mm (4") EXTRACTOR PAKS with aluminium flexible ducting and wall grille
XP100H฀
฀฀฀
฀
฀ ฀
฀
฀
PIR activated model which switches on as a person enters the room and
runs on after the room is vacated. There is no need to connect to a separate
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
XF100PIR
฀
฀
As above but with pullcord override switch. Requires no switched live
฀
฀
XF100HP
XF100H฀
฀
As XF100MH but with Electronic Timer
฀
As above but with pullcord switch and neon light
฀
XF100MHT
฀
XF100MHP
฀
฀
20-90% RH
฀
XF100MH
฀
As above but with pullcord override switch. Requires no switched live
฀
XF100TP
฀
฀
฀
As above supplied with pullcord switch
XF100T฀
Standard model for remote switching
XF100P
XF100S
฀
and easy cleaning.
thermoplastics for strength and durability, aesthetics
฀฀฀
opposite.
second, and is available in the ten options detailed
impressive extract rate of 85m3/hr, 23 litres per
฀฀฀
models for use in bathrooms and toilets.
comprehensive range offers a wide selection of
฀฀฀
100mm (4") Fan Range
Product type
100mm (4") Wall/ceiling Fans
Cat. No.
Technical Details
C
D
E
D
I
A
C
J
E
extended
Dimensions
WF100 Series
outside
A
B
Dimensions
XP100 Series
F
G
H
B
C
K inside
D
100mm (4") Range
Maximum pressure: 20 p.a.
Fan speed: 2400 r.p.m.
Sound volume: 41.0 dB(A)
Maximum operating temperature: 40ºC.
Additional Data
220-240V - AC. 50Hz . Single phase
consuming 14 watts. These fans are
double insulated and do not require an
earth. All wiring must comply with current
IEE regulations. A double pole isolating
switch, having a contact separation of
at least 3mm in all poles, must be used
with a 3 amp fuse fitted. The fan must
not be accessible to a person using
either the shower or bath and mounted a
minimum of 1.8 metres from the floor.
Electrical
WF100 Series designed for window
mounting through a standard 115 155mm Ø hole.
XP100 Series designed for through wall
fixing, supplied with aluminium flexible
ducting and external wall grille. Cut out
for XP100 kits (112mm/41/2").
XF100 Series designed for wall mounting
(pullcord version wall mounting only)
through 100mm (4") diameter flexible or
rigid pipes or Manrose low profile, flat
channel ducting systems.
Installation
WF100 Series in outers of 10 measuring
360mm x 210mm x 570mm - weight 9kgs
XP100 Series in outers of 10 measuring
380mm x 210mm x 765mm - weight 9kgs
XF100MH Series in outers of 10 measuring
572mm x 232mm x 413mm - weight 9kgs
XF100 Series in outers of 10 measuring
370mm x 200mm x 560mm - weight 7kgs
Packaging
21
technical
22
XF120/XP120/WF120
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
/hr, 36 litres per second.
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
Building Regulations on Ventilation (F1).
฀฀฀
easy cleaning.
฀
฀
thermoplastics for strength, durability, aesthetics and
฀฀฀
free life.
with pre-oiled bearings fitted for a long, maintenance
Power is provided by a single phase induction motor
฀฀฀
3
counterparts, yet only 10% larger in surface area.
fans are 56% more powerful than their 100mm (4")
and medium sized rooms, the 120mm (5") series of
฀฀฀
possess the latest design technology.
toilet fans are quiet in operation, easy to install and
฀฀฀
in ten options.
efficient range of axial flow extractor fans are available
฀฀฀
120mm (5") Fan Range
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
A
B
182
182
182 118Ø
182
32
182
92
B
A
B
C
C
D
D
G
380 118Ø
F
C
D
37
H
A
Dimensions WF120
outside
A
B
Dimensions XP120
C
D
E
78 118Ø
112
182
46 118Ø 120Ø
32
182 4-10
Dimensions XF120MH Series
A
Dimensions XF120
PRODUCT
XF120
XF120MH
XP120
WF120
Dimensions (mm)
฀
F
I
E
160
฀
glass
B
C
G
H
16
J
D
J
฀฀
I
As XF120MH but with electronic time
฀
XF120MHT
฀
As above with pullcord switch and neon light
฀
XF120MHP
฀
฀
20-90% RH
XF120MH฀
฀
PIR activated timer for presence detection that will run-on when the room
is vacated. Connection to a separate switch is not needed, (timer
฀
฀
฀
฀ ฀
฀ ฀
As above with pullcord override switch. Requires no switched live
฀
As above with pullcord override switch. Requires no switched live
฀
XF120PIR
XP120PIR
WF120PIR฀
WF120H
XF120HP
XP120HP
XP120H฀
XF120H฀
XF120TP
XP120TP
XF120T
XP120T
WF120T
As above supplied with pullcord switch
Standard Model for remote switching
XF120S
XP120S
XF120P
XP120P
WF120P
Product type
Cat. No.
Technical Details
XF/XP/WF120 Series 130m3/hr, 36 litres
per second
Performance Graph
120mm (5") Range
Maximum pressure: 35 p.a.
Fan speed: 2000 r.p.m.
Sound volume: 41.0 dB(A)
Maximum operating temperature: 40ºC
Additional Data
220-240V - AC. 50Hz . Single phase
consuming 15.5 watts. These fans are
double insulated and do not require an
earth. All wiring must comply with current
IEE regulations. A double pole isolating
switch, having a contact separation of
at least 3mm in all poles, must be used
with a 3 amp fuse fitted. The fan must
not be accessible to a person using
either the shower or bath and mounted a
minimum of 1.8 metres from the floor.
Electrical
WF120 Series designed for window
mounting through a standard
140mm - 150mm ø hole.
XP120 Series designed for through wall
fixing and comes complete with
aluminium flexible ducting and
external wall grille. Cut out for XP120
(140mm/5.5").
XF120 Series designed for wall or ceiling
mounting, (pullcord wall-mounting only).
Installation
WF120 Series in outers of 10 measuring
446mm x 225mm x 550mm - weight 10 kgs
XP120 Series in outers of 10 measuring
398mm x 210mm x 825mm - weight 10 kgs
XF120MH Series in outers of 10 measuring
760mm x 224mm x 447mm - weight 10 kgs
XF120 Series in outers of 10 measuring
400mm x 215mm x 490mm - weight 8 kgs
Packaging
23
technical
24
XF150B / XP150B / WF150B
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
/hr, 64
3
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
Regulations on Ventilation (F1).
฀฀฀
easy cleaning.
฀
฀
thermoplastics for strength, durability, aesthetics and
฀฀฀
same styling.
(4"), 120mm (5") and 150mm (6") fans, all with the
Manrose can now offer a complete family of 100mm
฀฀฀
litres per second.
฀฀฀
for a long, maintenance-free life.
single phase induction motor with pre-oiled bearings
shops, offices, restaurants, etc. Power is provided by a
฀฀฀
style.
alternative style and design to the traditional 6" kitchen
extractor fans are available in ten options, and are an
efficient and easy to install range of 150mm (6")
฀฀฀
150mm (6") Fan Range
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
A
203
203
95
203
B
203
150Ø
150Ø
203
C
95
72
180
4-10
B
D
A
B
D
side elevation
C
Dimensions XF150B Series
A
C
Dimensions XF150BMH Series
PRODUCT
XF150B
XF150MHB
XP150B
WF150B
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀฀
160Ø
23
E
400
F
B
F
extended
E outside
C
D
B
A
D
E
C glass
Dimensions WF150B Series
side
elevation
A
Dimensions XP150B Series
D
150Ø
203
180
95
PIR activated model with timer and presence detection, timer runs on
when the room is vacated. There is no need to connect to a separate
฀
฀
฀
฀
฀
฀
฀ ฀
฀
Dimensions (mm)
฀
฀
Pullcord switch
฀
฀
Electronic timer with pullcord override switch and neon light
฀
WF150BT
As above with pullcord switch and neon light
20 - 90% RH
฀
฀
฀
฀
฀
฀
timer runs on when the room is vacated.
WF150BP
WF150BPIR
฀
As above but with pullcord override switch. Requires no switched live
฀
As XF150MH but with electronic timer 150mm 6" Window Fans
WF150BH฀
฀
฀
As above but with pullcord override switch. Requires no switched live
฀
XF150BMHT
XF150BMHP
XF150BMH฀
XF150BPIR฀
XP150BPIR
XF150BHP
XP150BHP
XF150BH฀
XP150BH
XF150BTP
XP150BTP
XF150BT
XP150BT
As above supplied with pullcord switch
Standard model for remote switching
XF150BS
XP150BS
XF150BP
XP150BP
Product type
Cat. No.
Technical Details
XF/WF/XP150B Series230m3/hr, 64 litres
per second
Performance Graph
150mm (6") Range
Maximum pressure: 50 p.a.
Fan speed: 2400 r.p.m.
Sound volume: 40.0 dB(A)
Maximum operating temperature: 400C
Additional Data
220-240V - AC. 50Hz . Single phase
consuming 17 watts. These fans are
double insulated and do not require an
earth. All wiring must comply with current
IEE regulations. A double pole isolating
switch, having a contact separation
of at least 3mm in all poles, must be
used with a 3 amp fuse fitted. The fan
should not be accessible to a person
using either the shower or the bath and
mounted a minimum of 1.8 metres from
the floor.
Electrical
WF150B Series. These fans are designed
to be fitted in either a window or wall
through a standard 184mm (71/4") hole.
A wall fixing kit FK1 (1300) is available
which comprises of wall plugs, screws
and a 400mm length of 6" diameter
aluminium flexible ducting (when
fully extended).
XP150B Series. These fans are designed
for through wall fixing. Complete with
aluminium flexible ducting and a wall grille.
XF150B Series designed for wall or
ceiling mounting (pullcord wall-mounting
only). Wall fixing kit is available separately
The SVK (1280).
Installation
XP150B Series in outers of 10
measuring 1070mm x 263mm x 428mm
- weight 21kgs
WF150B Series in outers of 10
measuring 460mm x 640mm x 240mm
- weight 17kgs
XF150BMH Series in outers of 10. For
packaging dimensions, contact our
technical department
XF150B Series in outers of 10 measuring
595mm x 245mm x 450mm - weight 11kgs
Packaging
25
technical
26
XF/XP/WF100A/120A/150A
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀ ฀
฀ ฀
฀
฀
฀ ฀
฀
฀
฀
฀ ฀
฀฀
3
฀
/hr, 23
฀
฀ ฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀ ฀
Ventilation (F1).
฀฀฀
and easy cleaning.
฀
฀
฀
฀
฀
thermoplastics for strength and durability, aesthetics
฀฀฀
with pre-oiled bearings for a maintenance-free life.
฀฀฀
64 litres per second.
฀
฀
฀
150mm (6"), has a maximum performance of 230m3/hr,
36 litres per second. The largest fan in this range, the
powerful with an impressive extract rate of 130m3/hr,
bathrooms, toilets and utility rooms are 56% more
litres per second, whilst the 120mm units for larger
฀฀฀
120mm (5") and 150mm (6").
฀฀฀
after the fan is switched on.
interior grille which open silently approximately 45 seconds
incorporating thermo-activated internal shutters behind the
Automatic extractor fan range is available in ten options, all
฀฀฀
Automatic Shutter Fan Range
Product type
As above with pullcord override switch
Requires no switched live
XF100/120ATP/XFA150BTP
XP100/120ATP/XPA150BTP
WF100/120ATP/1WFA50BTP
Electro-mechanical humidity control with on/off
฀
฀
฀ ฀
฀
B
C
39 150Ø
160
XP120A
XPA150B 180
133
WFA150B 203
72
59
E
203
182
163
203
182
163
17 155Ø
16 125Ø
15 110Ø
72
59
53
D
G
98Ø
H
D
E
C
extended
F
Dimensions XF Series
A
outside
A
B
Dimensions XP Series
380 152Ø 150Ø
380 120Ø 118Ø
380 102Ø
F
B
H
115
112
108
I
G
J
C
D
inside
I
72
59
53
J
E
K
203
182
163
K
PIR activated model with timer for presence detection
฀ ฀
฀
฀
฀ ฀
฀
฀
฀
1-20 mins) Requires no switched live
As above with pullcord override switch. Requires no
switched live
฀
฀
฀ ฀
฀
฀ ฀
฀฀
XP100/120AH/XPA150BH 95% RH Complete with
฀
฀
฀
(1-20 mins)
(A) XF/XP/WF100A Series 85m3/hr, 23
litres per second
(B) XF/XP/WF120A Series 130m3/hr, 36
litres per second
(C) XF/XP/WFA150B Series 230m3/hr, 64
litres per second
Performance Graph
119
182
WF120A
115
163
WF100A
53
98Ø
37 118Ø
140
XP100A
33
112
115
108
182 118Ø
98Ø
XFA150B 203 150Ø
XF120A
A
163
XF100A
PRODUCT
Dimensions (mm)
XF100/120APIR/XFA150BPIR
XP100/120APIR/XPA150BPIR฀
WF100/120APIR/WFA150BPIR
XF100/120AHP/XFA150BHP
XP100/120AHP/XPA150BHP
WF100/120AHP/WFA150BHP
฀
XF100/120AH/XFA150BH฀
XF100/120AMHT/XFA150BMHT
XP100/120AMHT/XPA150BMHT Electro-mechanical humidity control with on/off switch,
WF100/120AMHT/WFA150BMHT฀
฀
฀ ฀
฀
฀
XF100/120AMHP/XFA150BMHP
XP100/120AMHP/XPA150BMHP As above with pullcord override switch and neon light
WF100/120AMHP/WFA150BMHP
XF100/120AMH/XFA150BMH
XP100/120AMH/XPA150BMH
WF100/120AMH/WFA150BMH฀
฀
฀
฀
electronic timer (1-20 mins)
XF100/120AT/XFA150BT฀
XP100/120AT/XPA150BT
฀
As above supplied with pullcord switch
Standard model for remote switching
XF100/120AP/XFA150BP
XP100/120AP/XPA150BP
WF100/120AP/WFA150BP
XF100/120A/XFA150BS
XP100/120A/XPA150BS
WF100/120A/WFA150BS
Cat. No.
Technical Details
A
Dimensions WF Series
B
C
150mm (6") Range
Maximum pressure: 50 p.a.
Fan speed: 2400 r.p.m.
Sound volume: 40.0 dB(A)
Maximum operating temperature: 40ºC
120mm (5") Range
Maximum pressure: 35 p.a.
Fan speed: 2000 r.p.m.
Sound volume: 41.0 dB(A)
Maximum operating temperature: 40ºC
100mm (4") Range
Maximum pressure: 20 p.a.
Fan speed: 2400 r.p.m.
Sound volume: 41.0 dB(A)
Maximum operating temperature: 40ºC
Additional Data
D
220-240 - AC. 50Hz
. Single phase
consuming 17 watts on the 100A, 19
watts on the 120A series and 20 watts on
the A150B series. These fans are double
insulated and do not require an earth.
All wiring must comply with current IEE
regulations. A double pole isolating switch,
having contact separation of at least 3mm
in all poles, must be used with a 3 amp
fuse fitted. The fan must not be accessible
to a person using either the shower or bath
and mounted a minimum of 1.8 metres
from the floor.
Electrical
XF100/120A/XFA150B Series designed
for wall or ceiling mounting (pullcord wall
mounting only). XP100/120A/XPA150B
Series designed for through wall fixing,
supplied with aluminium flexible ducting
and external wall grille. WF100/120A/
WFA150B Series designed for window
mounting.
Installation
XFA150B/XPA150B/WFA150B Series in
outers of 10 For packaging dimensions,
contact our technical department
WF120A Series in outers of 10 measuring
760mm x 224 x 447 - weight 11 kgs
XP120A Series in outers of 10 measuring
360mm x 220mm x 982 - weight 11 kgs
XF120A Series in outers of 10 measuring
760mm x 224mm x 447mm - weight 10
kgs
WF100A Series in outers of 10 measuring
360mm x 210mm x 695mm - weight 9 kgs
XF100A Series in outers of 10 measuring
595mm x 365mm x 205mm - weight
9 kgs XP100A Series in outers of 10
measuring 885mm x 360mm x 215mm weight 9 kgs
Packaging
27
technical
28
LW100/SELVLW100
80% energy saving
฀
฀
฀
฀
฀฀฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀ ฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀ ฀
Ventilation (F1).
฀฀฀
easy cleaning.
฀
฀
฀
฀
฀
Our new range of Lo-Watt fans are
specifically designed to meet the
regulations
The Building Regulations introduced in
2010 – Domestic dwellings, gives the
recommended Watts Per Litre (w/l/s)
for each type of fan, to be used in new
buildings.
New Building Regulations
2010 Domestic
฀
thermoplastics for strength and durability, aesthetics and
฀฀฀
impressive extract rate of 75m3/hr, 21 litres per second.
฀
฀฀฀
฀฀฀
฀ ฀
฀฀฀
฀
฀
฀฀฀
฀฀฀
mounting.
฀
Lo Watt Humidity Timer Fan Incorporating a 1-20min over run
฀
฀
฀
฀
LW100H
3
5
10 15 20 25 30
Volume I/Sec
A
B
Dimensions LW100
0
0
5
Dimensions Transformer
SELVLW 100
10
0.5
15
20
25
1
0
Volume m3/hr
20 40 60 80 100
1.5
2
2.5
0
LW100 75m3/hr at 21 litres per
C
SELVLW100H
30
Lo Watt Humidity Timer Fan Incorporating a 1-20min over run
฀
฀
฀
฀
SELVLW100T
Performance Graph
Lo Watt Standard Fan
Lo Watt Timer Fan Incorporating a 1-20min over run
SELVLW100S
Static pressure mm WG
฀฀฀
Lo Watt Timer Fan Incorporating a 1-20min over run
LW100T
Safety Extra Low Voltage (SELV) includes fan and transformer
Lo Watt Standard Fan
LW100S
Static pressure Pa
Lo-Watt™ Range
Product type
Cat. No.
Technical Details
Product
A
LW100
163
SELVLW 82
B
98
145
Dimensions (mm)
C
97
78
D
30
E
163
Maximum pressure: 20 p.a
Fan Speed: 3123 r.p.m
Sound volume: 38.0 dB(A)
Maximum operating temperature: 45ºC
Additional Data
220-240 - AC. 50Hz Single phase
Consuming 4.3watts. The LW100 is
powered by a brushless motor. All wiring
must comply with current IEE regulations.
A double pole Isolating switch, having
contact separation of at least 3mm in all
poles, must be used with a 3amp fuse
fitted. The fan must not be accessible to
a person using either the shower or the
bath (use SELV model) and mounted a
minimum of 1.8metres from the floor.
Electrical
LW100 Series designed for wall
mounting only. Through 100mm (4")
diameter flexible or rigid pipes.
Installation
29
technical
30
LOW VOLTAGE RANGE 100/120/150MM
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀ ฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀ ฀
฀
฀ ฀
฀
฀
฀
฀ ฀
฀
฀
Ventilation (F1), rated to IP44.
฀฀฀
life.
฀
฀
฀
with pre-oiled bearings for a long, maintenance-free
฀฀฀
and easy cleaning.
thermoplastics for strength and durability, aesthetics
฀฀฀
110m3/hr 31 litres per second.
฀฀฀
per second.
second and the 150mm 230m3/hr 64 litres
litres a second, the 120mm (5") 130m3/hr 36 litres per
฀ The extract rate of the 100mm (4") model is 85m3/hr 23
ducting and resistance by grilles.
฀
฀
฀
against the high pressures caused by longer lengths of
backward curved centrifugal impeller for large airflow
฀฀฀฀
shower.
and out of the reach of the person using the bath or
mounted inside the room where the fan is installed
pullcord, humidistat, PIR and versions have to be
on the ceiling next to the pullcord switch. Obviously
mounted remotely either in the roof space or high
motor. The transformer and switching mechanism is
model manufactured with a 12V - 50Hz shaded pole
use of conventional fans), the 12 Volt fan is a standard
shower or bath (where current regulations prevent the
฀฀฀
120mm (5") and 150mm (6") and in seven options.
(SELV) fans are available in three diameters - 100mm (4"),
฀฀฀
Safety Extra Low Voltage Bathroom/Shower Extractor Fans
12 Volt SELV Fan Range
A
Wall or ceiling model *
CF200LV
163
182
182
WF100LV
XF120LV
WF120LV
65
B
65
23
23
150Ø
150Ø
92
118Ø
90
98Ø
C
260
95
95
95
95
32
46
30
75
D
185
203
203
203
203
182
78
163
30
E
45
32
163
100
182
F
C
D
G
H
A
B
C
Dimensions WF150BLV/ WF150ALV
B
Dimensions CF200LV
E
D
F
90
135
B
See page 27 for dimensions on
WF120ALV
A
Dimensions WF120LV
See page 27 for dimensions on
WF100ALV
A
Dimensions WF100LV
(A) XF/WF100LV 85m3/hr, 23 litres per second
(B) XF/WF120LV 130m3/hr, 36 litres per second
(C) XF/WF150BLV 230m3/hr, 64 litres per second
(D) CF200LV 110m3/hr, 31 litres per second
Performance Graphs
CF200LV
WF150ALV 203
WF150BLV 203
XF150ALV 203
XF150BLV 203
A
163
PRODUCT
XF100LV
C
C
Window model/Automatic window model *
WF150BLV/WF150ALV
B
Wall or ceiling model/Automatic wall or ceiling model *
XF150BLV/XF150ALV
H
Window model/Automatic window model
WF120LV/WF120ALV
G
Wall or ceiling model/Automatic wall or ceiling model
XF120LV/XF120ALV
* Use LT12 Transformer
Window model/Automatic window model
WF100LV/WF100ALV
Dimensions (mm)
Product type
Wall or ceiling model/Automatic wall or ceiling model
Cat. No.
XF100LV/XF100ALV
Technical Details
D
D
B
C
B
A
B
C
D
D
C
Dimensions XF150BLV/ XF150ALV
A
Dimensions XF120LV
A
Dimensions XF100LV
D
12 volts AC. - 50Hz. 14W on XF/WF100,
20W on XF/WF120LV, XF/WF150BLV
and CF200LV. Supplied by a remote
safety isolating transformer - Manrose
type T12 series.
Electrical
F
E
E
CF200LV In outers of 10 measuring 753mm
x 283mm x 390mm - weight 12kgs
WF150BLV/ALV In outers of 10 measuring
460mm x 640mm x 240mm - weight 17kgs
XF150BLV/ALV In outers of 10 measuring
595mm x 245mm x 450mm - weight 11kgs
WF120LV/ALV In outers of 10 measuring
446mm x 225mm x 550mm - weight 10kgs
XF120LV/ALV In outers of 10 measuring
400mm x 215mm x 490mm - weight 8kgs
WF100LV/ALV In outers of 10 measuring
360mm x 210mm x 510mm - weight 9kgs
XF100LV/ALV In outers of 10 measuring
370mm x 200mm x 560mm - weight 7kgs
Packaging
31
technical
32
T12S/LT12S
T12 Series
remote Transformer
฀ ฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀ ฀
฀
knobs.
฀฀฀
฀
฀
and easy cleaning.
฀
฀
฀
฀
high gloss ABS thermoplastics for strength, durability
฀฀฀
light and complete with pattress.
฀฀฀
pullcord light switch.
or PIR models) or high-up on the ceiling next to the
be mounted in the loft area (not Pullcord, Humidistat
of Safety Extra Low Voltage (SELV) transformers can
the splash area of the shower or bath, the T12 series
฀฀฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
PIR Activated model which switches on when the room is entered
and runs on when the room is vacated.
As above with pullcord override switch. Requires no switched live
฀
Outside
Zones
B
2
0.6m
2
0.6m
Shower Zone Diagram
Outside
Zones
2
1
1
2
Bathroom Zone Diagram
A
2
0
2
0
1
2
2
0.6m
2
0.6m
Outside Zones
2
2
Outside
2.4m
Zones
C
Window recess Zone 2
Space under bath is Zone 1 if
accessible without tool
Zone 0
Zone 1
Zone 2
Outside Zones
Outside
Zones
Window recess Zone 2
Space under bath is Zone 1 if
accessible without tool
Zone 0
Zone 1
Zone 2
Outside Zones
Dimensions T12/LT12
Transformer
T12PIR/LT12PIR The fan requires no switched live, has no requirement to connect
฀ ฀
฀
฀
฀
฀ ฀
฀
฀
฀
LT models are for use with 150 Range and CF200LV
T12HP/LT12HP
T12H/LT12H฀
฀
As above with pullcord override switch. Requires no switched live
฀
T12TP/LT12TP
฀
฀
฀
(1-20mins)
T12T/LT12T฀
฀
As above supplied with pullcord switch
T12P/LT12P
Product type
Standard model for remote switching
T12S/LT12S
Cat. No.
Technical Details
Zone 2:
Extends to 0.60 metres
beyond Zone 1 to a height of
2.25 metres above the floor.
The exterior of the bath or
shower tray to a height of 2.25
metres above the floor.
C
66
65
78
Zone 1:
B
147
145
145
The interior of the bath or
shower tray.
A
86
82
82
Zone 0:
PRODUCT
T12S/T
T12P/TP/HP
LT12
Dimensions (mm)
Construction of transformer in
accordance with EN60742.
Transformer
Input 220-240V - 50Hz . Output 12volt
AC. 50Hz 25VA S.E.L.V. (35VA on LT Series)
Must be mounted out of reach of the
person using the bath or shower. These
appliances are double insulated and do not
require an earth, but must be connected
to the supply through a suitable double
pole isolating switch with a minimum
contact gap of 3mm on fixed wiring circuits.
The protective fuse must not exceed 3A
and installation must be supervised by a
qualified electrician. See zone diagram for
transformer zone rating.
Electrical
Packed in outers of 10 measuring 313mm x
97mm x 126mm - weight 10kgs.
Packaging
33
technical
34
SF100W/120W/150W
฀
฀
฀ ฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
Regulations on Ventilation (F1), rated to IP44.
฀฀฀
฀฀฀
clips, fixing screws and plugs.
external fixed louvre wall grille, self adhesive cable
telescopic ducting, one white internal and one grey
shutter, a length of 380mm flexible aluminium
tube fan with a mounted spring loaded backdraught
฀฀฀
performance of 230m /hr, 64 litres per second.
SF150W, the largest fan in the range, has a maximum
SF120W extracts 130m3/hr 36 litres per second. The
rate of 85m3/hr 23 litres per second, whilst the larger
฀฀฀
prevent the installation of conventional fans).
splash area of a shower or bath (where regulations
the internal wall which enables installation within the
mounted inside the wall, 175mm from the face of
฀฀฀
only 15mm.
rooms, the Slimline Wall Fan has a unique profile of
฀฀฀
Slimline Wall Fan Kit Range
Standard 5" model for remote switching
SF120W
(A) SF100W 85m3/hr, 23 litres per second
(B) SF120W 130m3/hr, 36 litres per second
(C) SF150W 230m3/hr, 64 litres per second
Performance Graph
In-line fan
Typical Installation
Fixed louvre wall grilles
Backdraught shutter
Standard 6" model for remote switching
Standard 4" model for remote switching
SF100W
SF150W
Product type
Cat. No.
Technical Details
SF100/120/150W with
flexible aluminium ducting
SF100W
SF120W
SF150W
See page 43.
(ID100/120/150 series)
Dimensions (mm)
150mm (6") Range
Maximum pressure: 50 p.a.
Fan speed: 2400 r.p.m.
Sound volume: 40.0 dB(A)
Maximum operating temperature: 40ºC
120mm (5") Range
Maximum pressure: 35 p.a.
Fan speed: 2000 r.p.m.
Sound volume: 41.0 dB(A)
Maximum operating temperature: 40ºC
100mm (4") Range
Maximum pressure: 20 p.a.
Fan speed: 2400 r.p.m.
Sound volume: 41.0 dB(A)
Maximum operating temperature: 40ºC
Additional Data
220-240V - AC. 50Hz
. Single phase
consuming 14W on SF100W, 15.5W on
SF120W and 20W on SF150W.
These fans are double insulated and
do not require an earth. All wiring must
comply with current IEE regulations. A
double pole isolating switch, having a
contact separation of at least 3mm in all
poles, must be used with a 3 amp fuse
fitted. The fan should not be accessible
to a person using either the shower or
bath, and mounted a minimum of 1.8
metres from the floor.
Electrical
Designed for mounting in-line in walls
and discharged through the flexible
aluminium ducting provided.
Installation
SF150W In outers of 10. For packaging
dimensions, contact our technical
department
SF120W In outers of 10 measuring
510mm x 234mm x 867mm - weight 13kgs
SF100W In outers of 10 measuring
605mm x 318mm x 745mm - weight 12kgs
Packaging
35
technical
36
SL/SLK 100MM 120MM & 150MM
Showerlite Range
฀
฀
฀ ฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀ ฀
฀
฀
฀
฀
ducting runs.
฀฀ ฀฀
฀
฀ ฀ ฀
฀
฀
฀
฀
ducting, external wall grille, fixing screws, plugs and straps.
Showerlite unit, transformer, one length of PVC flexible
supplied complete with fan (available with or without timer),
They are also available in a blister fan kit pack. Each pack is
packaging or in blister packs with or without transformer.
฀฀฀
providing a rich warm glow of soft light.
Manrose Showerlite will enhance any shower or bathroom
฀฀฀
centrifugal fans.
range of in-line axial fans or the CFD/MAN range of in-line
and 150mm (6") in-line system such as the Manrose SF/ID
฀฀฀
isolating transformer.
฀
Showerlite fan kit, standard model chrome fitting
Showerlite fan kit, standard model brass fitting
SL-120SC
SL-120SB
Showerlite fan kit, timer model brass fitting
Showerlite fan kit, timer model chrome fitting
Showerlite fan kit, timer model brass fitting
SL-150TW
SL-150TC
SL-150TB
PRODUCT
SL-W/B/C
SL120
SL150
A
140Ø
170Ø
200Ø
B
74
74
74
C
98
118
148
Showerlite centrifugal fan kit, timer model chrome fitting
SLCFDTC
Dimensions (mm)
Showerlite centrifugal fan kit, timer model white fitting
Showerlite centrifugal fan kit, timer model brass fitting
SLCFDSC
SLCFDTB
Showerlite centrifugal fan kit, standard model chrome fitting
SLCFDSB
SLCFDTW
Showerlite centrifugal fan kit, standard model white fitting
Showerlite centrifugal fan kit, standard model brass fitting
SLCFDSW
Centrifugal Packs Boxed Packaging
Showerlite fan kit, standard model brass fitting
Showerlite fan kit, timer model white fitting
SL-150SB
Showerlite fan kit, standard model chrome fitting
SL-150SC
Showerlite fan kit, standard model white fitting
SL-120TB
SL-150SW
Showerlite fan kit, timer model chrome fitting
SL-120TC
Showerlite fan kit, timer model white fitting
Showerlite fan kit, standard model white fitting
SL-120SW
SL-120TW
Showerlite fan kit, timer model chrome fitting
SLKTC
Showerlite fan kit, timer model white fitting
Showerlite fan kit, timer model brass fitting
SLKTB
Showerlite fan kit, standard model chrome fitting
SLKTW
Showerlite fan kit, standard model brass fitting
Showerlite fan kit, standard model white fitting
SLKSC
SLKSB
฀
SLKSW
฀
Showerlite with transformer chrome fitting
SL-CTB
Showerlite In-Line Axial Extractor Packs Blister Packaging
Showerlite with transformer brass fitting
Showerlite chrome fitting
Showerlite brass fitting
SL-BB
SL-CB
Showerlite with transformer white fitting
SL-WTB
SL-BTB
Showerlite white fitting
SL-WB
฀
฀
Transformer
T1250W
shower or bath and is powered by a S.E.L.V. remote safety
฀฀฀
and 150mm (6") versions.
and bathrooms. Now available in 100mm (4"), 120mm (5")
is incorporated into a circular diffuser, suitable for showers
฀฀฀
Showerlite chrome fitting
Showerlite Single Blister Packs
Showerlite brass fitting
SL-C
Showerlite white fitting
Product type
SL-B
SL-W
Boxed Cartons
Cat. No.
Technical Details
A
Dimensions
Typical Installation
B
C
All plastic components are moulded
in high temperature VO rated
thermoplastics.
Construction
12 volt 35W dichroic 5.3 sealed lamp.
Powered by a transformer T1250W. Input,
AC. Output, 12 volt AC. 50 VA.
Electrical
Designed to be ceiling mounted through
102mm (4") diameter flexible ducting or
rigid pipes.
Installation
Boxed in outers of 10. For packaging
dimensions, contact our technical
department.
Packaging
37
technical
38
MAN50/MAN50SF/MAN50SLK
฀
฀
฀ ฀
฀
175mm
Ø100mm
MAN50 Maximum pressure 120p.a.
Additional Data
All wiring must comply with the current
IEE regulations. A double pole isolating
switch, having a contact separation of
at least 3mm in all poles, must be used
with a 3 amp fuse fitted.
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀ ฀
฀
฀
ducting and resistance by grilles.
฀
฀
฀
฀
Showerlite fitting and transformer.
grilles together with a chrome
metres of PVC ducting and wall
centrifugal in-line fan unit, 6
which comprises of the MAN50
฀฀฀
and wall grilles.
฀
fan unit, 6 metres of PVC ducting
฀
caused by longer lengths of
฀
against the high pressures
฀฀฀
maintenance-free life.
of the MAN50 centrifugal in-line
฀
impellers for a large airflow
backward curved centrifugal
฀฀฀
with pre-oiled bearings for a long,
฀
shower rooms and utility rooms.
฀฀฀
Regulations on Ventilation (F1).
a single phase induction motor
฀
including bathrooms, toilets,
a wide range of applications
฀฀฀
comply with the 2006 Building
฀
litres per second.
฀
mounting bracket. Designed to
฀฀฀
have extract rates of 110m3/hr 31
unobtrusive, the MAN50 units
฀
and durability, aesthetics and easy
backdraughts.
฀฀฀
ABS thermoplastics for strength
discharge spigot to prevent
cleaning.
manufactured using high impact
฀
non-return flap is built into the
฀฀฀
MAN50 Range 110m3/hr, 31 litres per second
Maximum operating temperature: 40ºC
Sound volume: 45.0dB(A)
Performance Graph
180mm
220-240V - AC. 50Hz . Single phase
consuming 20W on the MAN50
Electrical
For packaging dimensions please
contact our technical department.
Fan speed: 1400 r.p.m.
฀
Timer model in-line fan kit (100mmØ)
MAN50TSFK
MAN50 Series in outers of 5
Packaging
ceilings, A spring operated,
฀
Timer model with bracket
MAN50T
MAN50TSLKC Timer model in-line Showerlite fan kit (100mmØ) Chrome
Standard model with bracket
MAN50S
designed for use with suspended
฀
systems.
฀ ฀
to cover most in-line ducting
฀฀฀
MAN50 in-line fan has been
฀ ฀
commercial applications, the
฀
ventilation accessories available
฀
wide range of domestic and
฀฀฀
Man50 In-line Centrifugal
Fan Range
Product type
Cat. No.
Technical Details
39
technical
40
PRO SHOWERLITE
for easy fan installation in
the roof.
The first in-shower ventilation
kit incorporates seven
3
A bracket is also included
in your house.
1
2006 building regulations.
bathroom or any other area
7
5
4
4
2
equipment within one kit.
4
6
bathroom.
4
of soft light to enhance any
provides a rich warm glow
waterproof protection. It
is a sealed unit for total IP
attractive chrome finish and
The Showerlite fan has an
to reduce to 100mm/4".
a built in extended reducer,
120mm/5" Showerlite with
An attractive powerful
50lps, which exceeds the
extend the ventilation in your
2
capable of extracting 180hr
powerful way, to totally
different pieces of ventilation
centrifugal fan. This is
provide an effective and
A powerful high
performance In-line
1
The kit includes:
everything you require to
so much more. It includes
Showerlite fan kit gives you
The complete Professional
6
5
4
3
7
for your total ventilation.
showerlite.The complete kit
to power the 12 volt
(SELV) transformer,
A safety extra low voltage
Showerlite.
fan, internal grille and
ducting to the in-line
which connects the PVC
A PVC T-Piece connector,
install guide).
soffit. (see installation for
which fits into the external
the egg crate wall grille,
in-line fan extracts through
An external wall grille; the
size room.
adapt the installation in any
long length enables you to
flexible PVC ducting. This
10 metres of 100mm/4"
unobtrusively into any room.
unique design, and will fit
white grille, which has a
this is a circular internal
One additional inlet,
Professional Showerlite Fan Kit
Boxed in outers of one.
Please contact our technical department
for further details.
A
B
3
1
B
Ø135mm
Ø140mm
Ø100mm
Ø100mm
Ø165mm
272mm
ØA
C
B
ØA
74mm
140mm
33mm
250mm
10mm
136mm
B
C
D
dØ
ØD
C
A
B
5
B
4
C
A
2a
100mm
100mm
dØ
C
A
120mm
Ø250mm
D
B
2
117mm
50mm
15mm
100mm
E
Ød
72mm
E
VENTILATES POWERFULLY & ILLUMINATES SAFELY
ØA
1
2
2a
3
4
5
PRODUCT
Dimensions
Catalogue Number
PROCFSLKC
In-Line Centrifugal Fan
Performance: 180m3h 50lps
Fan speed: 2500 rpm
Max Operating Temperature: 60ºC
Sound Level: 43.0 dB(A)
Weight: 2kg
Additional Data
In-Line Centrifugal Fan
4 pole single phase induction motor with
ball bearings fitted for a long, maintenancefree life and protected by a thermo-auto
resetting cut-out approved totally enclosed
for protection against dirt and dust. Motors
are continually rated.
Motor
In-Line Centrifugal Fan
Strong impact light grey plastic casing.
Showerlite Fan
All plastic components are moulded in high
temperature VO rated thermoplastics.
Construction
In-Line Centrifugal Fan
Induct Fans suitable for in-line systems
and designed for use with suspended
ceiling systems.
Showerlite Fan
Designed to fit through a 120mm/5"
diameter hole with an incorporated
reducer to fit 100/4" PVC ducting.
Installation
Electronic transformer for LV-Halogen
lamps.
Input: 230V-50-60Hz
Output: 12V 20-60W
Transformer
220-240V- AC. 50Hz
Single phase
consuming 32 watts. These fans are
double insulated and do not require an
earth. All wiring must comply with current
IEE regulations. A double pole isolating
switch, having contact separation of at
least 3mm in all poles, must be used
with a 3 amp fuse fitted.
In-Line Centrifugal Fan
Showerlite Fan
12 volt 35W dichroic 5.3 sealed
lamp. Powered by a transformer
T1250W. Input, AC output, 12 volt AC.
50VA dimmable.
Electrical
Packaging
1
2
3
4
5
6
7
In-line centrifugal duct fan with mounting bracket
1 x 120mm/5" Showerlite unit with chrome fitting & fixed reducer to 100mm/4"
1 x Circular Internal White Grille
10 metres of 100mm/4" PVC Flexible Ducting
1 x Egg Crate External Wall Grille
1 x PVC T-Piece Connector
1 x Low Volt Transformer
The Professional Showerlite kit is supplied complete with:
Technical Details
41
41
technical
42
SF100/120/150 ID100/120/150
฀
฀
฀
฀
฀
฀
฀ ฀
฀ ฀
฀
฀
฀
฀
Ventilation (F1).
2006 Building Regulations on
฀฀฀
maintenance-free life.
litres per second.
pre-oiled bearings for a long,
฀ ฀
performance of 230m3/hr, 64
฀
phase induction motor with
฀ ฀
ID150 Tube Fan, with a top
฀฀฀
Also new to the range is the
130m3/hr 36 litres per second.
performs with an impressive
cleaning.
฀
durability, aesthetics and easy
using high impact ABS
฀฀฀
per second, whilst the SF/ID120
฀
thermoplastics for strength and
฀
SF/ID100 is 85m3/hr 23 litres
฀
operation, the extract rate of the
฀฀฀
฀ ฀
where a long run of ducting is used.
their 100mm counterparts.
and are 56% more powerful than
฀
suitable for boosting another fan
฀
larger shower or bathroom areas,
฀
comprises a fan unit only and is
฀฀฀
engineered for the ventilation of
series of in-line fans have been
฀฀฀
screws, plugs and straps to
secure the duct to the grilles.
one external wall grille, fixing
฀
mounted remotely.
฀ ฀
ducting, one internal (white) and
฀ ฀
shock in wet areas as the fan is
฀
remove any risk of an electric
฀฀฀
unit, one length of PVC flexible
฀
supplied complete with a fan
฀
4") range of in-line extractor fans
฀
rooms, the SF/ID 100 (100mm
฀
the SF100/120/150 fan kits are
฀
of bathrooms, toilets and shower
฀฀฀
Shower/In-line Fan Range
฀
฀
(1-20 mins)
SF100/120/150T฀
B
B
C
A
Dimensions
ID100/120/150 Series
A
Dimensions
SF100/120/150 Circular
and Square Grille
PRODUCT
A
ID100
98Ø
ID120
116Ø
ID150
148Ø
ID100S
130
ID120S
150
ID150S
187
SF100S/T Up to 3m
SF120S/T Up to 4m
SF150S/T Up to 5m
Dimensions (mm)
A
B
90
99
110
155
155
153
140
160
180
C
100
118
150
90
99
109
140
160
180
E
15
16
15
F
D
G
Internal
grey grille
H
10
10
10
H
I
I
฀
J
J
50 98Ø
50 116Ø
50 148Ø
฀
฀
External
grey
grille
Dimensions
ID100S/120S/150S
Series with Bracket
140
140
140
G
Showerfan screwed
฀
E
C
27
27
27
33
37
35
Flexible
Ducting
100Ø
118Ø
150Ø
100Ø
125Ø
150Ø
D
Performance may vary depending on the length of ducting used
SF/ID150 Up to 230m3/hr, 64 litres per second
SF/ID120 Up to 130m3/hr, 36 litres per second
SF/ID100 Up to 85m3/hr, 23 litres per second
Performance
฀
฀
฀
(1-20 mins)
ID100/120/150T฀
฀
Standard model for remote switching with bracket
ID100/120/150S
฀
Standard model (tube fan) for remote switching
฀
ID100/120/150
ID In-line fans
Standard model for remote switching
SF100/120/150S
฀
In-line fan kits with PVC duct and wall grilles
SF
฀
Product type
Cat. No.
Technical Details
150mm (6") Range
Maximum pressure: 50 p.a.
Fan speed: 2400 r.p.m.
Sound volume: 40.0 dB(A)
Maximum operating temperature: 40ºC
120mm (5") Range
Maximum pressure: 35 p.a.
Fan speed: 2000 r.p.m.
Sound volume: 41.0 dB(A)
100mm (4") Range
Maximum pressure: 20 p.a.
Fan speed: 2400 r.p.m.
Sound volume: 41.0 dB(A)
Maximum operating temperature: 40ºC
Additional Data
220-240V - AC. 50Hz
. Single phase
consuming 14W on ID100, 15.5W on
ID120 and 20W on ID150. These fans
are double insulated and do not require
an earth. All wiring must comply with
current IEE
regulations. A double pole isolating
switch, having a contact separation of
at least 3mm in all poles, must be used
with a 3 amp fuse fitted.
Electrical
The shower fan is easy to install in the
average loft/ceiling recess as after the
hole has been cut in the ceiling of the
shower/room, all other work is continued
outside the living area.
Installation
ID150/S/T In outers of 10 contact our
technical department for packaging
dimensions
ID120/S/T In outers of 10 measuring
328mm x 179mm x 567mm - weight 7kgs
ID100/S/T In outers of 10 measuring
282mm x 176mm x 490mm - weight 6kgs
ID150 In outers of 10. For packaging
dimensions, contact our technical
department
ID120 In outers of 10 measuring
264mm x 144mm x 567mm - weight 5kgs
ID100 In outers of 10 measuring
220mm x 125mm x 490mm - weight 4kgs
SF150 In outers of 5 measuring
440mm x 393mm x 1083mm. Volume 1.873
SF120 In outers of 10 measuring
620mm x 396mm x 917mm - weight 17kgs
SF100 In outers of 10 measuring
515mm x 350mm x 820mm - weight 16kgs
Packaging
43
technical
44
SF150A/ID150A
฀
฀
฀ ฀
฀
฀฀฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
152mmØ.
ducting supplied is one 5m length
Ventilation (F1).
฀ ฀
and the fan unit, whilst the PVC
฀฀฀
maintenance-free life.
pre-oiled bearings for a long,
2006 Building Regulations on
฀
฀ ฀
phase induction motor with
฀฀฀
secure the duct onto the grilles
screws, plugs and straps to
supplied complete with fixing
or as In-line fan kits, which are
฀฀฀
ducting used.
depending on the length of
฀
and external grilles. The flexible
durability, including the internal
reinforced with steel wire.
฀
ducting is made from PVC
฀
to 220m3/hr 62 litres per second,
฀
has a powerful extract rate of up
฀฀฀
thermoplastics for strength and
฀
using high impact ABS
฀ ฀
remotely.
฀
removed as the fan is mounted
฀฀฀
make installation simple.
฀ ฀
has easy to follow instructions to
฀
with water.
฀
there is a possibility of contact
฀฀฀
and sports facilities, the SF150
฀
bars and meeting rooms, schools
฀
and bathrooms, or any where
฀ ฀
ventilation of larger shower rooms
฀
rooms with showers, restaurants,
฀
have been designed for the safe
฀฀฀
150mm (6") In-line Fan Kit Range
Product type
A
฀
B
D
฀
C
B
฀
฀
C
฀
฀
฀
Typical Installations
Internal white
grille
Flexible ducting
SF150/ID150 Up to 220m3/hr, 62 litres per second
Maximum Fan performance stated, this can vary depending on the length of ducting used
Performance
A
Dimensions SF150/ID150 Series
Dimensions ID150 Series
฀
Standard model for remote switching
ID150AT ฀
ID150A
฀
฀
฀
฀
฀
automatic in-line shutters
SF150AT ฀฀
฀
Standard model for remote switching
SF150A
In-line fan kits with PVC duct and wall grilles incorporating automatic in-line shutters
Cat. No.
Technical Details
B
180
180
C
180
180
D
Up to 5m
External
grey grille
The 150mm (6”) in-line fan
attached to the floor
above the suspended ceiling
PRODUCT
A
SF150A 152Ø
ID150A 152Ø
Dimensions (mm)
150mm (6") Range
Maximum pressure: 50 p.a.
Fan speed: 2400 r.p.m.
Sound volume: 40.0 dB(A)
Maximum operating temperature: 40ºC
Additional Data
220-240V - AC. 50Hz
. Single
phase consuming 20W on the SF150A
automatic models. These fans are double
insulated and do not require an earth.
All wiring must comply with the current
IEE regulations. A double pole isolating
switch, having a contact separation of
at least 3mm in all poles, must be used
with a 3 amp fuse fitted.
Electrical
The 150mm shower fan is easy to install
in the average loft/ceiling recess as,
after the hole has been cut in the ceiling
of the shower/room, all other work is
continued outside the living area.
Installation
ID150 In outers of 10 measuring
755mm x 229mm x 428mm volume 0.07m3
SF150 In outers of 5 measuring 440mm x
393mm x 1083mm volume 1.87m3
Packaging
45
technical
46
CF100/CF200/CF400
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
easy cleaning.
฀
฀ ฀
฀
฀ ฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
Regulations on Ventilation (F1).
฀฀฀
fibre filter.
฀
฀
fans are also supplied with a 11mm thick washable
for a maintenance free life of over 40,000 hours. These
external rotor motors which incorporate ball bearings
฀฀฀
long, maintenance-free life.
phase induction motor with pre-oiled bearings for a
฀฀฀
and
thermoplastics for strength and durability, aesthetics
฀฀฀
second.
has a maximum performance of 230m3/hr, 64 litres per
per second. The largest fan in the range, the CF400
CF200 range have an extract rate of 110m /hr 31 litres
3
has an extract rate of 90m3/hr 20 litres per second, the
฀฀฀
backdraughts.
non-return flap into the discharge spigot to stop
฀฀฀ ฀
resistance by grilles.
pressures caused by long lengths of ducting and
units will give maximum performance even against
฀฀฀
restaurants, hotels and offices.
for kitchens and commercial applications, such as
cloakrooms, utility rooms, and the CF400 is designed
CF100/200 ranges are designed for bathrooms, toilets,
yet very quiet and vibration free ventilation. The
the latest technology to provide extremely powerful,
฀฀฀
Centrifugal Fan Range
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀
฀
฀
Electronic humidity control with pullcord override switch
Requires no switched live
฀
฀
As above with pullcord override switch. Requires no switched live
฀
As above supplied with pullcord switch
฀
D
D
90
260
350
B
E
163
45
45
D
98Ø
98Ø
F
C
90
153
G
G
H
110m3/hr, 31 litres per second
C
65
185
265
A
D
Performance Graph CF200
B
98Ø
65
60
A
90m3/hr, 25 litres per second
A
163
65
70
E
F
B
Dimensions CF400 Series
G
H
E
Dimensions CF200 Series
Performance Graph CF100
PRODUCT
CF100
CF200
CF400
Dimensions (mm)
B
C
A
Dimensions CF100 Series
C
135
198
H
F
E
CF100PIR฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
CF200PIR run on when room is vacated (1-20 mins). Requires no switched live
CF400PIR
CF200HP
CF400HP
CF100H฀
CF200H฀
CF400H
CF100TP
CF200TP
CF400TP
CF100T
CF200T฀
CF400T
CF100P
CF200P
CF400P
฀
฀
230m3/hr, 64 litres per second
Performance Graph CF400
CF400
Maximum pressure: 300 p.a.
Fan speed: 2335 r.p.m.
Sound volume: 58.0 dB(A)
Maximum operating temperature: 89ºC
CF200
Maximum pressure: 120 p.a.
Fan speed: 1400 r.p.m.
Sound volume: 45.0 dB(A)
CF100
Maximum pressure: 80 p.a.
Fan speed: 1600 r.p.m.
Sound volume: 42.0 dB(A)
Additional Data
220-240V - AC. 50Hz
single phase
consuming 17W on the CF100 range,
17W on the CF200 range and 45W on
the CF400 range. These fans are double
insulated and do not require an earth. All
wiring must comply with current IEE
regulations. A double pole isolating switch,
having a contact separation of at least 3mm
in all poles, must be used with a 3amp fuse
fitted. The fan should not be accessible to a
person using either the shower or bath and
mounted to a minimum of 1.8 metres from
the floor.
Electrical
Designed to be mounted on walls or
ceilings and discharged through a
100mm (4") standard rigid or flexible
duct, and are also suitable for use
with flat duct channel systems.
Comprehensive wiring and installation
instructions are included with each fan.
Installation
CF400 Series in outers of 5 measuring
290mm x 400mm x 920mm - weight 14kgs
CF200 Series in outers of 10 measuring
753mm x 283mm x 390mm - weight 12kgs
CF100 Series in outers of 10 measuring
340mm x 175mm x 835mm - weight 11kgs
CF100S
CF200S
CF400S
Standard model for remote switching
Packaging
Cat. No. Product type
Technical Details
47
technical
48
M200S
฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
/h (15l/s) to
3
฀
฀฀฀
฀฀฀
฀ ฀
฀
฀ ฀
฀
฀
฀
comply with the Building Regulations (Document F)
฀฀฀
versions.
฀฀฀
฀฀฀
฀
Available as a wall model with the addition of a wall fitting kit.
via rigid, flexible or flat ducting.
Designed for wall or ceilings mounting and discharging
vertical ducted system.
in 2 positions allowing for rear exit or connecting to a
impeller assembly. The rear spigot can be mounted
due to the unique cassette design of the motor and
M200 is designed for surface or flush mounting
for ducted ventilation of internal bathrooms and WC’s.
The M200 range of centrifugal bathroom fans are designed
M200 Centrifugal Bathroom Fan
Single speed fan with integral back draught shutters Integral
฀ ฀ ฀ ฀
฀
฀
฀
฀
฀
฀ ฀฀฀
requirements of Part F Building Regulations 2006, for installed
performance
Single speed fan with integral back draught shutters. Integral
฀
฀
฀
฀
฀ ฀
฀ ฀
Building Regulations 2006, for installed performance
Electronic Humidity control with pullcord over ride switch requires no
switched live.
M200T
M200H
฀
M200HP
Flush Fitting
C
Dimensions
E
70m3/hr 20 litres per second
Surface Mount
D
Single speed fan with integral back draught shutters. Pullcord
operation. Meets the requirements of Part F Building Regulations
2006, for installed performance
M200P
Performance Graph M200
Single speed fan with integral back draught shutters. Light or remote
switch operation. Meets the requirements of Part F Building
Regulations 2006, for installed performance
M200S
B
฀ ฀฀
Product type
Cat. No.
Technical Details
A
PRODUCT A
B
M200
210 265
Dimensions (mm)
C
100
D
90
M200
Maximum pressure: Sound volume:
36.0 dB(A) Maximum operating
temperature: 40ºC
Additional Data
E
17
220-240V - AC. 50Hz single phase
consuming 11W on the M200 range,
These fans are double insulated and
do not require an earth. All wiring must
comply with current IEE regulations. A
double pole isolating switch, having a
contact separation of at least 3mm in all
poles, must be used with a 3amp fuse
fitted. The fan should not be accessible
to a person using either the shower or
bath and mounted to a minimum of 1.8
metres from the floor.
Electrical
Designed to be mounted on walls
or ceilings and discharged through
a 100mm (4") standard rigid or
flexible duct, and are also suitable for
use with flat duct channel systems.
Comprehensive wiring and installation
instructions are included with each fan.
Installation
M200 Series in outers of 10 measuring
753mm x 283mm x 390mm – weight 12kgs
Packaging
49
technical
50
XF150/WF150
฀ ฀
฀
฀ ฀
฀
฀
฀
฀
฀
฀฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀ ฀ ฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀ ฀
฀
฀ ฀
฀
฀
฀
฀ ฀
฀
฀
฀
Regulations on Ventilation (F1).
฀฀฀
life.
฀
฀
with pre-oiled bearings for a long, maintenance-free
฀฀฀
and easy cleaning.
thermoplastics for strength and durability, aesthetics
฀฀฀
WF150 range is suitable for window mounting.
rooms, restaurants, hotels, offices and shops. The
commercial applications including kitchens, utility
XP150 range is ideally suited to use in domestic and
฀฀฀
second on the WF150.
for the XF/XP version and 220m3/hr 62 litres per
฀
฀
powerful extract rate of 230m3/hr 64 litres per second
has been designed for simple installation, and has a
฀฀฀
be wall, ceiling or window mounted.
(6") axial flow kitchen fans are quiet, efficient and can
฀฀฀
6" Wall and Window Fan Range
Product type
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀
฀ ฀
฀
฀
฀
฀
฀
Standard model
A
B
฀
฀
฀
C
D
D
A
A
B
฀
฀
E
C
F
D
฀฀
฀฀
PRODUCT A
B
C
D
E
F
XF150
203 203 95 150Ø
XF150A 203 203 95 150Ø
XP150
95 150Ø 400 160Ø 180 180
WF150 203 203 95
23
Dimensions (mm)
C
D
Dimensions XP150 Series
B
Dimensions XF150A Series
(A) XF/XP/150 Series 230m3/hr, 64 litres per second
(B) WF150 Series 220m3/hr, 62 litres per second
Performance Graphs
A
SIDE
ELEVATION
THROUGH
GLASS
Dimensions WF150 Series
B
C
Humidity control complete with pullcord
Timer model complete with pullcord
Pullcord model
Standard model
Dimensions XF150 Series
WF150AH
WF150AT
WF150AP
WF150A
Automatic model with internal shutters
Timer model complete with pullcord
Humidity control complete with pullcord
WF150H
Pullcord model
WF150T
WF150P
WF150
฀
Electronic humidity control with pullcord override switch
Requires no switched live
฀
WINDOW FANS - Basic model with fixed grilles
XF150AHP/XP150AHP
XF150AH/XP150AH
฀
฀
฀
฀
timer (1-20 mins)
XF150AT/XP150AT฀
Standard model for remote switching
As above supplied with pullcord switch
XF150AP/XP150AP
XF150A/XP150A
฀
Electronic humidity control with pullcord override switch
Requires no switched live
฀
฀
WALL/CEILING FANS AND PAKS - Automatic model with internal shutters
XF150HP/XP150HP
฀ ฀
฀
฀
XF150H/XP150H
฀
฀
฀
฀
timer (1-20 mins)
฀
As above with pullcord switch
XF150T/XP150T฀
Standard model for remote switching
XF150P/XP150P
XF150/XP150
WALL/CEILING FANS AND PAKS - Base model with fixed internal grille
Cat. No.
Technical Details
Maximum pressure: 50 p.a.
Fan speed: 2400 r.p.m.
Sound volume: 40.0 dB(A)
Maximum operating temperature: 40ºC
Additional Data
220-240V - AC. 50Hz
. Single phase
consuming 17W on the 150 series and
20W on the 150A automatic models.
These fans are double insulated and
do not require an earth. All wiring must
comply with the current IEE regulations.
A double pole isolating switch, having a
contact separation of at least 3mm in all
poles, must be used with a 3 amp fuse
fitted. The fan should not be accessible
to a person using either the shower or
bath and mounted a minimum of 1.8m
from the floor.
Electrical
WF150/WF150A this series has been
designed for window or wall fixing through
฀
฀ ฀
a standard 184mm (71/4 ฀
wall fixing, please use the FK1 wall vent
kit Cat No. 1300. There are two variations
in the range, the base model with fixed
louvres for additional trickle flow ventilation
and the automatic model incorporates
thermoactivated internal shutters (except
the pullcord operated model WF150AP).
XP150/150A This series has been designed
for through wall fixing and is supplied
complete with aluminium flexible ducting
and wall grille. The XP150/150A series
of 150mm (6") extractor fans can be
wall mounted, and there are two models
available in this range. The XP150 model
has a fixed louvre internal grille, whilst the
automatic model the XP150A, has thermoactivated internal shutters which open 45
seconds after the fan has been switched
on (except the manual pullcord operated
model XP150AP).
The XF150/150A series of 150mm (6")
extractor fans can be wall or ceiling
mounted (not pullcord models), and there
are two models available in this range.
The XF150 model has a fixed louvre
internal grille, whilst the automatic model
the XF150A, has thermo-activated internal
shutters which open 45 seconds after
the fan has been switched on (except the
manual pullcord operated model XF150AP).
Installation
WF150 In outers of 10 measuring
460mm x 640mm x 240mm - weight 17kgs
XP150 In outers of 10 measuring 1070mm
x 263mm x 428mm - weight 21kgs
XF150 In outers of 10 measuring
595mm x 245mm x 450mm - weight 11kgs
Packaging
51
technical