Hufcor, Inc.

Transcription

Hufcor, Inc.
Hufcor, Inc.
New Products Presentation
Fall 2011
Series 640V
VERTICAL STACKING
OPERABLE PARTITIONS
Hufcor Summit 640V
Hufcor Summit 640V
Designed to offer vertical stacking option for standard operable
walls
Openings up to 40’ wide x 17’3” tall
Untrimmed standard Hufcor 640 Series Panel Construction
STC 52 (+/- 1)
Stacks in patent-pending drive box system above the ceiling
Standard finishes – vinyl, fabric, carpet, and approved COM
“Trim” colors – lambs wool, brown, grey & clear anodized
Stringent Safety Features
Hufcor Summit 640V
640V - Product Positioning
1. NOT SKYFOLD. Hufcor Summit is vertical stacking not vertical folding.
2. Vertically stacks above the ceiling verse at the ceiling
3. Designer-Friendly slot in ceiling verse 6’ wide ceiling stack trench
4. Designer-Friendly - single piece construction verse accordion
pantograph folding
5. Fully automated , patent-pending design – new, clean technology
6. Time-tested operable partition panel construction – accepted globally
7. No interior moving parts within the panel – reduce maintenance and
servicing
640V - Product Positioning
8. Acoustical performance of 52 (+/- 1).
9. Auto-reverse lead edge obstruction detection system.
10. Easy access to movable parts inside guide rails and accessible
drive assemblies
11. Panels park and cascade individually and as such make panelto-panel seal connections above the ceiling, reducing liability
and risk of pinch points.
640V - Product Positioning
12. Stringent, redundant safety devices
o
o
o
o
o
o
o
motor torque brake
lead edge, auto reverse obstruction detection
load arrestor (free fall safety)
two, directional key switch with push button operation
audio enunciator indicates panel system is in motion
photo eyes
UL listed components
13. Guide Rail – exposed and partially recessed
o Lateral stability
o House Safety elements
o Acoustical effectiveness
o Installation ease – lifting of panels reduced
640V - Product Positioning
14. Designer-friendly standard finishes, including approved COMs
15. Structural Loads – static, similar to accordion style systems
with stamped calculations.
16. Architect-friendly BIM drawings available
o Speeds design process
o Conflict detection and resolution
17. Seismic sound to withstand Zone 4 conditions.
1. NOT SKYFOLD
First, the Summit 640V is not Skyfold. We are a newly designed
system that provides similar benefits of vertical folding operable
walls.
Summit 640V is vertical stacking
Vs.
Skyfold Classic® is vertical folding
1. NOT SKYFOLD
Summit 640V sizing is optimized to 40’ x 17’ 3” openings
Vs.
Skyfold Classic® is is not limited by width and installed up to
36’ tall openings
Summit meets the sizing parameters of 86.5% of all projects
listed on Skyfold’s website.
2. Vertical Stacking
Summit 640V stacks above the ceiling
Vs.
Skyfold Classic® stacks in the ceiling
2. Vertical Stacking above vs. vertical folding within.
Summit 640V
Skyfold Classic
2. Vertical Stacking vs vertical folding
6’2” slot & trim
11” slot & trim
Summit 640V
Skyfold Classic
3. Vertical Stacking vs vertical folding
Summit 640V clean
ceiling design
Skyfold ceiling sacking
trench
4. Single Piece Construction
Summit 640V offers single piece construction
Vs.
Skyfold Classic® multiple vertical seam construction
5. Fully Automated, patent-pending design
Summit 640V offers new single panel stacking technology
Vs.
Skyfold Classic® dated accordion-style folding
6. Standard operable partition construction
Summit 640V offers standard Hufcor welded steel panel
construction with skinned steel faces.
Vs.
Skyfold Classic® dated accordion-style folding
7. No Internal Moving Parts
Summit 640V offers standard steel skinned panels
without internal moving parts
Vs.
Skyfold Classic® dated accordion-style folding with
dozens of internal moving parts and motors
8. Acoustical Performance
Summit 640V offers 51 - 52 STC (current prototype tests)
Vs.
Skyfold Classic® offers 51 STC
Goal for Summit 640V: 52 – 54 STC
9. Auto Reverse of Lead Edge Sensor
Summit 640V offers auto reverse with lead edge obstruction
Vs.
Skyfold Classic® does not.
10. Easy Access inside Guide Rails
Summit 640V offers guide rails
Vs.
Skyfold Classic® does not.
Guide Rail Benefits:
o Lateral stability
o House Safety elements
o Acoustical effectiveness
o Installation ease – lifting of
panels reduced
o Recessed offers aesthetic
profiles
11. Panel-to-Panel stacking occurs above ceiling
Summit 640V virtually eliminates pinch points.
Vs.
Skyfold Classic® multiple pinch point during operation.
12. Stringent, code compliant safety features
Summit 640V offers unmatched safety features.
Vs.
Skyfold Classic® provides minimal features for overhead
stacking door systems.
12. Stringent, code compliant safety features
Summit 640V offers free fall load arrestors.
Vs.
Skyfold Classic® does not.
12. Stringent, code compliant safety features
Summit 640V offers motor torque brake.
Vs.
Skyfold Classic® only offers this form of slowing device.
12. Stringent, code compliant safety features
Summit 640V offers AUTO REVERSE lead edge obstruction.
Vs.
Skyfold Classic® only offers lead edge stop system.
12. Stringent, code compliant safety features
Summit 640V offers audio enunciator during operation.
Vs.
Skyfold Classic® does not.
13. Standard designer finishes
Summit 640V offers standard finishes
(horizontal pattern only)
Vs.
Skyfold Classic® offer standard finishes, plus wood veneer,
stainless steel, HPL and others.
14. Structural Loads
Summit 640V requires static load overhead structure
calculations
Vs.
Skyfold Classic® requires static load overhead structure
calculations.
15. BIM Drawings
Summit 640V offers BIM drawings.
Vs.
Skyfold Classic® offers BIM drawings
15. BIM Drawings
o Easier to Design
o Conflict Detection & Resolutions
16. Seismic calculates
Summit 640V withstands seismic movements in Zone 4 and stamped
testing to be provided soon.
Vs.
Skyfold Classic® seismic performance not called out in their specifications
What Summit 640V cannot do.
Summit cannot be provided in larger opening sizes than listed.
Summit requires a minmum of 44” – 51” of clearance
underneath the structural support and ceiling height.
Summit cannot provide “T” conditions with another Summit
Summit cannot do stair stepped or sloped panels
What Summit 640V cannot do.
If, Summit cannot be provided in larger opening sizes than listed.
o Offer standard operable walls as alternative options
o Offer to build down a soffit to reduce ceiling height or
design with a column.
o Offer to design a system that does work.
What Summit 640V cannot do.
If, the design calls for “T” or intersecting vertical stacking systems.
o Offer Summit in one direction and Hufcor op wall the other.
o Demonstrate what intersecting Skyfold ceiling conditions
look like and ask, “is this what you want specified?”
o Schedule Hufcor’s new AIA CES program titled,
“Flexibility is Moving in a New Direction…..UP.”
Intersecting vertical folding
partitions require soffit
cutouts
Stacking soffits must be
increased as the opening size
increases
Stair stepped Skyfolds
dangle down from the ceiling
– leaving an very
aesthetically challenging
ceiling design.
Stair stepped Skyfolds
cannot guarantee an even
horizontal splice from section
to section.
Offer a standard Hufcor
operable partition for stair
steps or sloped designs
Series 640V
“Innovation at its Highest”
Hydrau-Lift™ Bifold Doors
Hydrau-Lift™ BiFold Doors
Hydrau-Lift™ BiFold Doors - Product Characteristics
• Welded Steel Frames
• smaller sized tube frames
• cleaner/smaller weld joints
• Hydraulic SST lifting system (patented technology)
• Located on far sides of system – clear views
• pulls door in tight to frame for better weather seal and
security
• Eliminates cables and straps and unsightly door kickouts
• Is provided standard with commercially available storefront
system components
• Only complete door system on the market today
Hydrau-Lift™ BiFold Doors - Product Characteristics
• Single lift systems available as option
• Sizes available range from 18’ wide to 16’ tall
(Larger sizes are available on special requests.)
• Only system on market to have been tested for air, water
and wind loads (positive/negative pressures).
•Air - <.030 cfm @ 1.57psf
• Water – ASTM water spray
• Wind Loads:
• DP-30 (108 mph –tested to 145mph)
• DP-15 (49 mph – tested to 89 mph)
Advancement to Hydrau-Lift Systems
o Size Increases – hinge improvements
o Different applications
o Different Surfaces
Acoustic Glasswall - Upgrades
New competitive pricing continued
New product features
Mini blinds now available
Inset hinged pass door available
Lever closure with glass inserts now available
Coordinated Solid Faced Panels now available
ALLVU™
Automated Moveable
Glass Wall Systems
Introducing SMARTITION
SMARTITION
New operable wall system that allows schools share technology
Smartition rotates/spins 180-degrees
Smartition has internal wiring, conduit and cabling
Smartition integrates with interactive whiteboard technologies
Starboard EZ-LinkTechnology systems from Hitachi available to
Hufcor distributors exclusively
Smartition is installed on Hufcor Unispan® providing specification
advantages and sole sourcing opportunities
Field proven and tested – Hufcor Texas Group @ Keller ISD
SMARTITION
Hitachi Starboards
Link EZ systems
SMARTITION
Chosen by national CEFPI team to be featured
in Classroom of the Future 2021 project.
RG Designer Series Faces
Rotogravure Painted
Faux Wood
Exclusively Supplied to Hufcor by:
Rotogravure Paint Process:
five separate coats
clear coat finish
½” medium density fiberboard (MDF)
The exclusive multi-step
finish process creates intricately
detailed finishes that are highly
durable and easy to maintain.
Hufcor RG Designer Selections
Alum Rock Maple
Autumn Cherry
Georgetown Anigre
Tropical Mahogany
Monticello Anigre
Eastern Walnut
Market Benefits:
1. Durability – baked top coat is easy to clean
and is installed in hundreds of national chain
stores and restaurants.
2. Price – less expensive than HPL and Wood
Veneer
3. Simplicity of Process – Easy to install at
factory.
4. Specifiable within Section 9 of the finishes
section.
High Acoustic Panel Construction
56 STC (computer modeling)
o 16 ga. steel faces
o High density gyp – 2.3 psf vs.
1.6 psf
o Side cushion seal on vertical
o Infill top & bottom seals with
dense material
o Control surrounding
construction
49 - 50 NIC
High Acoustic Panel Strategy
56 STC (computer modeling)
49 - 50 NIC Field Testing
High Acoustic Panel Strategy
Acoustician Endorsement
Hufcor FlexTact®
Reconfigurable Wall Systems
For Scenario Based Training
Thank you.
Any Questions?