Optifire
Transcription
Optifire
Instructions for use and maintenance Optifire Caution: Remove the instructions from the fireplace and give them to the client, along with the necessary instructions (explanations and demonstrations). 07DHOPFV2 01/09 Optifire 1 For the chimney sweep, tick the correct position of the baffles (see 1.5). 2 Opti- Dear Client, We congratulate you on the purchase of your Bodart & Gonay fireplace. We are happy to inform you that you have chosen a quality product wholly designed and manufactured by our company, using the most up-to-date production techniques. To get the best use out of your appliance, we strongly recommend that you read these instructions carefully and keep them safe. Also keep your proof of purchase safe, as it will be used to determine the guarantee period. We wish you lots of pleasure and warmth around your Bodart & Gonay fireplace. Customer Services. MEMO (to be completed by the installer) *DISTRIBUTOR: Name ......................................................... * APPLIANCE TYPE OPTIFIRE *REFERENCE: OPTI700 : OPTI760 : OPTI760DF: * DATE OF PURCHASE: ..... / ..... / ..... Street / No. ................................................... Town ............................................... Postcode ............................................. Tel. ........................................................... * SERIAL NUMBER: (visible on the fireplace’s identification label, see page 4 no.11 Description of elements) ………………………………………………… Note: Your supplier is the specialist chosen by BODART & GONAY to represent your region. For your safety and satisfaction, we recommend that you have them carry out your installation All local and national regulations and European standards must be observed when installing and using the appliance. If, however, you wish to carry out the installation yourself, to avoid any surprises, we recommend that you: - consult the terms of our guarantee agreement, - seek advice from your supplier. Concerning installation, given the impossibility of covering every particular case that might arise, we will confine ourselves to the most important points. Optifire 3 CONTENTS RECOMMENDATIONS 1. Fuel 2. First fire 3. With each fire 1. Use: 1.1. Description of elements 1.2. Opening – closing the fireplace 1.3. Fire behaviour 1.3.1. Lighting 1.3.2. Ideal rate 1.3.3. Reduced rate 1.4. Operating with coal (occasional) 1.5. Adjusting baffles 1.6. Fans and speed variator 2. Maintenance: 4 4 4 5 5 6 6 7 7 8 8 9 10 11 2.1. Everyday maintenance 2.2. Annual servicing 3. Faults 4. Spare parts 5. Guarantee 11 12 13 14 23 RECOMMENDATIONS 1. Fuel: OK! This appliance burns (well dried!) wooden logs and logs of compressed wood shavings. Do not put too much wood in at once. You can also use briquettes. This appliance may not under any circumstances be used as an incinerator! It can also occasionally burn coal (anthracite or lean coal) of 12/22 or 20/30 grade. It is prohibited, however, to burn coke or other fuels containing sulphur. 2. First fire: Bakes the paint, which causes a release of fumes and odours. Ventilate the room! Do not touch the paint until the fireplace has cooled down, as initially it softens before hardening for good. 3. With each fire: - Close the door of the ash box - Position the grill properly depending on the fuel - Turn on the fan (except for minimum rate) 4 Opti- 1. Use: 1.1. Description of elements 12 11 10 9 6 8 1 7 5 3 4 2 1. The gate: Never leave it open when the appliance is in operation 7. Microswitch: A switch that automatically stops the fan on opening the door. 2. The thermostat: It regulates the quantity of primary air for combustion according to its position. Its valve closes and opens according to the temperature of the combustion chamber. Its control knob is telescopic to facilitate operation. 8. Fireplace identification label 3. The ashtray door: It gives access to the ashtray and to the deashing arm. It must always be closed during a fire (otherwise the combustion air is no longer under control and the fire flares up -> overheating of appliance). 4. The deashing arm :To use it, pull it towards you. It is used to adapt the fireplace to the type of fuel (left-hand position: open grill for coal; right-hand position: closed grill for wood). Deashing is done by moving it from right to left. 5. The ashtray: In the form of a shovel to enable collection of ashes right at the bottom of the appliance. Monitor the amount of ash in the ashtray and empty it before it overflows. 6. Door lock and removable handle: With the gate closed, place the removable handle in the hole in the door latch to open and close. 9. Log-guard: For safety. 10. Refractory bricks or cast iron plates: a natural material that protects the heating unit whilst limiting variations in temperature. 11. Baffles: Made of heat-resisting stainless steel, they lengthen the path of fumes optimising secondary combustion and increasing heat transfer. They enable the fireplace to be adapted to the draught of the chimney. 12. Inner door: These are hardwearing stainless steel seals, to guarantee air tightness of the door and trouble-free clearing of smoke from the glass. 13. Distributors: They enable regular distribution of primary air. 14. Grills: They are made of heat-resisting cast iron, and the upper grill is operated by the deashing arm. Optifire 5 15. The variator: It enables adjustment of fan speed. 1. Speed adjustment. 2. Minimum speed adjustment screw under the knob 3. Fuse (Remove the knob, unscrew the plate, remove old fuse, replace with identical fuse). 1 2 3 Do not forget to calibrate the variator; refer to the installation manual in options 6. 1.2. Opening – closing the door During the fire, open the door slowly. Opening it suddenly causes a temporary backdraft in the fireplace. To close the door: lift the handle, press the door against the heating unit so that the seal is gently compressed, then lower the handle until it is locked. It is normal for the fan to cut out when opening the door. 1.3. Fire behaviour The quality and the drying of the wood are of prime importance for the fireplace to operate at its best (heater power and yield, cleanliness of glass). Quality wood is: - Dry wood that has been drying for at least 2 years in a ventilated sheltered area. - Use logs from broad-leaved trees in preference to those from conifers, which tend to burn quickly and produce lots of soot. In order of preference: hornbeam, oak, beech... - It is also possible to use logs of compressed wood shavings and briquettes. An excessive load of wood leads to: - A reduction in yield and an increase in wood consumption. - A significant loss of heat through the chimney. - Premature ageing of the fireplace and chimney flue. 6 Opti- OK! 1.3.1. Lighting 1. OPEN the air control to maximum: Thermostat 9. Place the grill in open position (lever to the left). 2. Lay firelighter or crumpled-up newspaper. Finish off with kindling. The use of inflammable liquids is prohibited. 3. Set light to it. 4. To avoid condensation of fumes on the glass and to facilitate starting the fire: Leave the door slightly ajar to prevent the glass sooting up, as its still too low temperature causes condensation and deposit of particles. 5. Wait for the kindling to be well lit before LAYING the first logs, choosing the smallest ones first. 6. As soon as there are strong flames and the glass is sufficiently warm, close the door completely. 7. When the fire is blazing, close the grill and the ashtray and start the fan (Variator "ON" see 1.6). 8. When the appliance is hot, adjust the thermostat to the required position. 9. Adapt the fan speed to the quantity of hot air you need. 1.3.2. Ideal rate for good yield 1. Choose split logs (1or 2 depending on the quantity of heat needed) 2. Try to pile them in staggered rows to encourage gas exchanges. 3. Put the thermostat on 7-8. 4. Put the fan on maximum. A sign of good combustion with wood, after a phase of degassing where the fireplace interior turns black, during the actual combustion, this black tar must be burned and the fireplace interior must appear clear, then blacken again with the following load and then be reburned once again. For better yield, it is best to have the thermostat on 7-8 and load log-by-log depending on the quantity of heat you need. This also enables you to keep the glass, bricks and chimney cleaner. Also ensure that you close the baffles as far as possible and ideally put in place the third baffle if your chimney allows it (see 1.5 Adjusting baffles). Maximum permitted load at maximum rate: Model Maximum load (for reduced rate): Recommended load for 1 hour at maximum rate: OPTI700 9Kg OPTI760 11Kg OPTI760DF 11Kg 3,5Kg 4,5Kg 3,68Kg Optifire 7 1.3.3. Reduced rate and long-lasting combustion Maximum permitted load in one go at reduced rate (see previous table). 1. Keep a 3 to 5 cm bed of embers at the bottom of the fireplace. 2. Choose logs with a very wide section. 3. Position the thermostat according to the draught of your chimney. A reduced rate is generally achieved between 0 and 3. This kind of load can only be used at reduced rate, to produce a long-lasting fire. Piling logs in parallel encourages a long-lasting fire. Add more logs when there are only embers left, just after the last flames die out. Continuous use at reduced rate may, through condensation, cause an accumulation of soot in the chimney, and thereby a risk of chimney fire, and dirty the glass more quickly. Avoid reduced rate during unfavourable atmospheric conditions (low pressure and high humidity), as there is a risk of backdraft. 1.4. OPERATING WITH COAL Use coal only in an casual way. Use coal (anthracite or lean coal) of 12/22 or 20/30 grade. Fuels containing sulphur, like coke and its by-products for example, are prohibited. NB. Do not use the appliance with coal in mild weather. As the draught and rate are reduced, combustion is liable to become incomplete. 1. Position the GRILL in OPEN position. 2. OPEN the air control to maximum: THERMOSTAT 9. 3. Lay crumpled (non-glazed) paper and KINDLING in the fireplace. 4. SET LIGHT TO IT. 5. Leave the door slightly AJAR to prevent the glass sooting up, as its still too low temperature causes condensation and deposit of particles. 6. As soon as the GLASS is sufficiently HOT, CLOSE THE DOOR. 7. START the FAN in MEDIUM POSITION (see 1.6). 8. Put the coal WITHOUT SPREADING IT OUT on the grill. 9. When the fire has penetrated the mass (appearance of flames), add a SECOND LOAD. 10. Allow the fire to continue to progress before reducing GRADUALLY the air intake up to the position corresponding to the calorific requirement. 11. ADJUSTING FAN SPEED. 8 Opti- CAUTION! When the fireplace is being used, and even if there are no more flames, certain accessible parts of the appliance are at very high temperatures. Do not leave children unsupervised near the fireplace. ! 1.6. Fans and speed variator Caution ! The fan is engaged when the temperature switch is hot (+ 20 min.) MAX. OFF= O MINI. ON 60 15 45 OFF= O O 30 Optifire 9 1.5. Adjusting baffles: Most open position: the fireplace is delivered with this configuration. It allows easy passage of fumes. Caution: lower baffle perforations on left. Intermediate position: if no backdraft is observed on opening, it is possible to close the baffles slightly to increase yield. Caution: lower baffle perforations on right, turn baffle round. Most closed position: if there is still no backdraft in intermediate position, close it fully to always have the best yield the fireplace can give in relation to the chimney. Third baffle: if there is still no backdraft in closed position, you can install the third baffle. Again with the aim of obtaining the best yield the fireplace can give in relation to the chimney. Prohibited position: 10 Opti- Except: OPTI 760 D Most open position: the fireplace is delivered with this configuration. It allows easy passage of fumes. Intermediate position: if no backdraft is observed on opening, it is possible to close the baffles slightly to increase yield. Most closed position: if there is still no backdraft in intermediate position, close it fully to always have the best yield the fireplace can give in relation to the chimney. Optifire 11 2. Maintenance: 2.1. Everyday maintenance GLASS To clean the glass, open the door using the following procedure: CAUTION! - Do not clean the glass when it is hot. - Spray the product* on the centre of the glass, then spread it using a cloth or absorbent paper. - Do not use water and/or cleaning products on the painted areas. - For stubborn marks, it is possible to use a blade for scraping ceramic hobs. - Cleaning the glass is easier if done regularly. *We recommend use of the cleaning product “BG Clean”, available from your dealer. “BG Clean” does not contain caustic soda and is biodegradable. AIR DISTRIBUTORS Where necessary, unblock the air inlet holes of the front distributor with a vacuum cleaner, as well as those situated on both sides of the grill, which can easily be removed to facilitate the operation. GRILLS Make sure that there are no obstacles restricting their movement. DUST FILTERS (if there are any, they are level with the air inlets) Clean them with a vacuum cleaner and, where necessary, with water. New filters can be obtained form your supplier. THERMOSTAT Check that it turns properly. Your supplier is authorised to check the setting. DOOR Check that the stainless steel seal is airtight. If necessary, your supplier can adjust and/or replace it. Check that both the lock and the opening safety work properly. This is in order to ensure good yield and clean glass. ASHTRAY DOOR Check the condition of the seal and if necessary replace it to ensure air tightness. Degradation of this seal leads to poor fire control and reduction in yield. Check the operation of the spring clips. 12 Opti- 2.2. Annual servicing CHIMNEY-SWEEPING Have the chimney swept at least once a year, not only to comply with the law, but also for safety reasons. - Take note of the position of the 2 baffles. - Remove the baffles, as shown in the drawing. - If the third baffle is installed, you must first take down the 2 large baffles, unscrew the third baffle and remove it, then manoeuvre and remove the two large baffles. - Place the grill in closed position (wood). - Close the door, thermostat and ashtray door. - Simply clean up any fallen dust with a vacuum cleaner. Take advantage of the chimney-sweeping to check the chimney and connections. condition of the - Reposition the baffles following the instructions in reverse, taking care to position them as before. LUBRICATION With frequent use, it is recommended that the following parts be lubricated annually: - Door and gate: hinges and lock. - Thermostat: control shaft. DO NOT USE NORMAL LUBRICANT. At high temperatures the latter will dry out and cause seizing up. If necessary, clean the surfaces thoroughly, then apply a LUBRICANT RESISTANT TO HIGH TEMPERATURES, available from your dealer. PAINTING METAL PARTS Do not use water and/or cleaning products on the painted areas. Stained areas may be restored using special B&G high temperature aerosol paint, which is available from your dealer. FAN (as option) UNPLUG the electricity supply, DISCONNECT the fan, and then REMOVE it. CLEAN the impeller blades using a brush (COMPRESSED AIR IS PROHIBITED). REASSEMBLE everything. FIREPROOF BRICKS A split brick can still play a protective role. However, a missing piece must be replaced in order to maintain effective protection of the heating unit. Bricks are wearing parts that can be easily replaced individually. You are advised to change parts that are too damaged. Optifire 13 3. Faults FAULTS SOLUTIONS GLASS GETS DIRTY TOO QUICKLY -Check that the fuel is not damp. - Use the thermostat on 7-8. - Check the position of the air detector. - Open the baffle passage. FAN Not working any more - Check if the motor is working. - Check the micro switch. - Check (and replace) the variator fuse. - Check the temperature switch (option). - Check (and restore) the power supply. FAN Operates but the output is weak - Check that the wires of the speed variator are properly positioned. - Clean or replace the filters. - Clean the impeller blades. DRAUGHT Too strong Tighten the baffle passage (see “Adjusting baffles”) - Contact your supplier. DRAUGHT Too weak, possibly with fumes leaking into the room - Check the chimney (see installation instructions). - Remove any obstructions. - Open the baffle passage. - Check if there is any improvement when the window is open. - Have the chimney swept. Disruptions connected with weather conditions - If this condition is permanent, consult your supplier. THE FIRE LACKS INTENSITY - Check that the fuel is not damp. - Check the thermostat (put it on 7-8 and check its movement). - Empty the ashtray. - Unblock the distributor holes. THERMOSTAT NO LONGER CLOSES: - A foreign body is preventing the valve from closing - Mechanical blockage - Remove the foreign body. - Replace the thermostat. THERMOSTAT STAYS SHUT: 1. On COLD, the valve only raises from medium positions 2. On COLD, the valve does not raise any more 1) Recalibrate the setting. 2) Replace the thermostat (it has been damaged following major overheating of the fireplace). UNCONTROLLABLE FIRE: - DOOR of ashtray open or not airtight - DOOR of fireplace not airtight - THERMOSTAT does not shut - Check the ashtray door closes properly. - Check the seal, and replace it where necessary. - Readjust the door seal setting. - Readjust the position of the lock roller. - Check operation of the thermostat. In the event of a CHIMNEY FIRE, close immediately the door and the ashtray door, turn off the thermostat. 14 Opti- 4. Spare parts Optifire 15 OPTIONS/RECHANGES/OPTIE/WISSELSTUKKEN OPTI 700 Pièces de rechange / wisselstukken Ref 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 19 20 22 23 24 25 26 27 28 29 30 31 33 36 37 38 39 40 42 Code 07BP03 27M70016 07RV1050 27M70015 27660002 27660000 37M70014 37M70015 07CB300 07CB315 07CB344 07CB313 07CB326 07CB325 07CB327 07FFIFG 37B78013 37M70034 37M70035 37M70029 37660016 37M70016 37B78006 37B78008 37B78007 27B78014 07PBE001 37B78009 07FTS690 07PBB049 37116226 37B77016 37117400 07VM0200 37M70033 37M70003 Description poignée fil 07BP0103 NOIRES PORTE SOUDEE OPTI 700 PLAT CERAM. 596 X 497 X 4 OPTI 700 CONTREPORTE OPTI 700 PLAT FERMETURE IF 96 ACCROCHE CLENCHE IF 96 CHICANE SUPERIEURE OPTI 700 626 x 166,6-75 CHICANE INFERIEURE OPTI 700 626 x 221 BRIQUE 240X120X30 VT20 BRIQUE 300X150X30 BRIQUE 300X90X30 BRIQUE 240X60X30 (BISEAUTEE) BRIQUE 150X60X30 BISEAUTEE BRIQUE 180X60X30 BISEAUTEE BRIQUE 120X60X30 BISEAUTEE SA-PAIRE GRILLES IF-GAUMAIS-POELE BUTEE GRILLE AVANT OPTI 780 PAIRE DE REPARTITEUR OPTI 700 CANAUX D'AIR FOND OPTI 700 BARREAU PARE BUCHE OPTI 700 SUPPORT BARREAU-CHENET IF 96 DEFLECTEUR OPTI 700 PLAT SUPPORT GRILLES OPTI 780 CENDRIER OPTI 780 BRAS DECENDRAGE OPTI 780 CAISSON CENDRIER OPTI 780 SACLIPS PORTE CENDRIER D950207 PORTE CENDRIER OPTI 780 THERMOSTAT DIA90 TELESCOPIQUE POUSSOIR CADRE IF 60 VH FIXATION SONDE STABILISATEUR OPTI 780-700 (SOUVERAIN) BUSELOT AIR CHAUD DIA 125 BUSELOT RACCORD.CHEMINEE DIA 200 TROISIEME CHICANE OPTI 700-760 PAIRE PIEDS OPTI 700 Options / opties Ref 01 34 34 41 43 44 45 45 46 47 48 Code 37B78005 27M70027 27M70026 07EEG006 37B78004 37660050 37M70011 37M70018 37B77021 37B78024 37660078 Description KIT GRIL BARBECUE OPTI 780 - OPTI 700 PORTILLON CADRE 3 C. OPTI 700 PORTILLON CADRE 4 C. OPTI 700 - 760 DF SA - MICROSWITCH 831611 IW3 + 161L UL BOITIER ELECTRIQUE OPTI 780 THERMOCONTACT MONTE 2006 CADRE HAB. 3 COTES OPTI 700 CADRE 4 COTES PLAT OPTI 700 KIT VENTILATION 450 M3 HARNAIS OPTIFIRE 780 SAV KIT VARIATEUR blanc ENCASTRABLE IF96 Omschrijving ZWARTE KOUDE HANDGREEP GELASTE DEUR OPTI 700 VLAK KERAM. 596 X 497 X 4 OPTI 700 TEGENDEUR OPTI 700 VLAK SLUITING IF 96 HENDEL VANGER IF 96 BOVENSTE ROOKAFREMMER OPTI 700 ONDERSTE ROOKAFREMMER OPTI 700 VUURV.STEEN 240X120X30 VT20 VUURV. STEEN 300X150X30 VUURV. STEEN 300X90X30 VUURV.STEEN 240X60X30 KANTG. VUURV.STEEN 150X60X30 KANTG. VUURV.STEEN 180X60X30 KANTG. VUURV.STEEN 120X60X30 KANTG. VUURROOSTER INFIRE GAUMAIS-KACHEL VOORSTE ROOSTER BLOK OPTI 780 PAAR LUCHTVERDELERS OPTI 700 LUCHTKANALEN BODEM OPTI 700 BLOKKENHOUDER OPTI 700 STEUN BLOKKENHOUDER IF 96 LUCHTDEFLECTOR OPTI 700 VLAK ROOSTER SUPPORT OPTI 780 ASLADE OPTI 780 ROOSTERSTANG OPTI 780 ASLADE AFSLUITPLAAT OPTI 780 VEERKLEM ASLADE DEUR ASLADE DEUR OPTI 780 THERMOSTAAT Ø90 TELESCOPISCH KADER DRUKKNOP IF 60 VH BEVESTIGING HAARBUISJE SOEVEREIN STABILISATOR WARMELUCHTBUISJE DIA 125 INOX AANSLUITINGSBUISJE DIA 200 DERDE ROOKAFREMMER OPTI 700-760 PAAR VOETEN OPTI 700 Omschrijving kIT BARBECUE OPTI 780- OPTI 700 DEURTJE 3Z KADER OPTI 700 AFDEKPLAAT4 Z KADER OPTI 700 - 760 DF MICROSWITCH MET DRUKKNOP ELEKTRISCH KASTJE OPTI 780 GEMONTEERD THERMOCONTACT 2006 3Z KADER OPTI 700 4 ZIJ. KADER VLAK OPTI 700 VENTILATIE KIT 750 M3 PHENIX OPTIFRE 780 KABELSET KIT INBOUWDIMMER IF96 Imprimé, le 16/10/2007 16 Opti- Optifire 17 OPTIONS/RECHANGES/OPTIE/WISSELSTUKKEN OPTI 760 Pièces de rechange / wisselstukken Ref 01 01 02 02 03 03 04 04 05 06 07 08 09 09 10 10 11 11 14 15 16 18 19 19 20 21 22 23 24 25 26 27 28 28 29 30 31 32 33 34 35 36 37 44 45 ----- Code 27B78016 27B78017 27B78015 27B78021 07RV1039 07RV1041 27660002 27B78022 07BP03 27660000 37B78014 37B78015 07CB300 07FF0301 07CB315 07FF0305 07CB344 07FF0306 07CB325 07CB327 37B78013 37B76034 07FFIFG2 07FFIFG3 37B78007 07PBE001 37B78009 37B78006 37B78008 27B78014 37660016 37B78029 37B78016 37B78026 07FTS690 37116226 37B77016 37117400 07VM0200 07PBB049 37115018 37M70003 07EEG006 37B76035 37M70033 37B78070 37B78075 Description PORTE SOUDEE OPTI 780 PLAT PORTE SOUDEE CINTREE OPTI 780 CONTREPORTE OPTI 780 PLAT CONTREPORTE OPTI 780 CINTREE CERAM. 656X487X4 OPTI 780 + OPTI 760 DF CERAM.R.900 DEV.638 H.490 EP.4 FERMETURE IF 96 FERMETURE PORTE CINTREE OPT780 MAIN FROIDE NICKEL.IF96+PRISMA ACCROCHE CLENCHE IF 96 CHICANE SUPERIEURE OPTI 780 686 x 166,6-75 CHICANE INFERIEURE OPTI 780 686 x 221 BRIQUE 240X120X30 VT20 PLAQUETTE FONTE 240X120X30 BRIQUE 300X150X30 PLAQUETTE FONTE 300X150X30 BRIQUE 300X90X30 PLAQUETTE FONTE 300X90X30 BRIQUE 180X60X30 BISEAUTEE BRIQUE 120X60X30 BISEAUTEE BUTEE GRILLE AVANT OPTI 780 PAIRE DE REPARTITEUR OPTI 760 GRILLE ACIER CHR. SUP. LG 266 GRILLE FONTE INF. LG 300 BRAS DECENDRAGE OPTI 780 SACLIPS PORTE CENDRIER D950207 PORTE CENDRIER OPTI 780 SUPPORT GRILLES OPTI 780 CENDRIER OPTI 780 CAISSON CENDRIER OPTI 780 SUPPORT BARREAU-CHENET IF 96 BARREAU PARE BUCHE OPTI 780 DEFLECTEUR OPTI 780 PLAT DEFLECTEUR AIR OPTI 780 CINTRE THERMOSTAT DIA90 TELESCOPIQUE FIXATION SONDE STABILISATEUR OPTI 780-700 (SOUVERAIN) BUSELOT AIR CHAUD DIA 125 BUSELOT RACCORD.CHEMINEE DIA 200 POUSSOIR CADRE IF 60 VH TISONNIER PAIRE PIEDS OPTI 700 SA - MICROSWITCH 831611 IW3 + 161L UL PAIRE DE CANAUX AIR OPTI 760 TROISIEME CHICANE OPTI 700-760 1/2 KIT FONTE OPTI 780 - 700 1/2 KIT BRIQUE OPTI 780/700 Options / opties Ref 38 39 40 41 42 43 43 43 ------------- Code 37660050 37B78004 07EEVENC 37B78024 37B78023 37M76011 37B76018 37M76020 07EVDDA6 3774H024 37B78005 37B77032 37M76027 27B78029 18 Opti- Description THERMOCONTACT MONTE 2006 BOITIER ELECTRIQUE OPTI 780 VARIATEUR A ENCASTRER(S.CABLE) HARNAIS OPTIFIRE 780 SAV KIT VENTILATION OPTI 780 - 700 CADRE 3 COTES PLAT OPTI 760 DF CADRE 4 C. PLAT OPTI 760 + CACHE THERMOSTAT CADRE 3 COTES CINTRE OPTI 760 DF SA-VENTILATEUR DDL 133-200 (+ CONDENSATEUR 2µF) BOIT.FILT REPRISE 25X16 LAITON KIT GRIL BARBECUE OPTI 780 - OPTI 700 CAISSON VENTILATION 450 M3 KIT CLAPET PIVOTANT OPTI 760-760 DF PORTIL.CINTRE CADRE 3C OPTI780 Omschrijving GELASTE DEUR OPTI 780 VLAK GEBOGEN GELASTE DEUR OPTI 780 TEGENDEUR OPTI 780 VLAK TEGENDEUR OPTI 780 AFGERONDE KERAM. 656X487X4 OPTI 780/760/760D KERAM.R.900 DEV.638 H.490 EP.4 Opti 780 SLUITING IF 96 SLUITING GEBOGEN DEUR OPTI 780 ZWARTE KOUDE HANDGREEP HENDEL VANGER IF 96 BOVENSTE ROOKAFREMMER OPTI 780 ONDERSTE ROOKAFREMMER OPTI 780 VUURV.STEEN 240X120X30 VT20 GIETIJZER PLAATJE 240X120X30 VUURV. STEEN 300X150X30 GIETIJZER PLAATJE 300X150X30 VUURV. STEEN 300X90X30 GIETIJZER PLAATJE 300X90X30 VUURV.STEEN 180X60X30 KANTG. VUURV.STEEN 120X60X30 KANTG. VOORSTE ROOSTER BLOK OPTI 780 PAAR LUCHTVERDELERS OPTI 760 BOVENROOSTER+CHROME LG 266 ONDERROOSTER LG 300 ROOSTERSTANG OPTI 780 VEERKLEM ASLADE DEUR ASLADE DEUR OPTI 780 ROOSTER SUPPORT OPTI 780 ASLADE OPTI 780 ASLADE AFSLUITPLAAT OPTI 780 STEUN BLOKKENHOUDER IF 96 BLOKKENHOUDER OPTI 780 LUCHTDEFLECTOR OPTI 780 VLAK LUCHTDEFLECTOR OPTI780 ROND THERMOSTAAT Ø90 TELESCOPISCH BEVESTIGING HAARBUISJE SOEVEREIN STABILISATOR WARMELUCHTBUISJE DIA 125 INOX AANSLUITINGSBUISJE DIA 200 KADER DRUKKNOP IF 60 VH POOK PAAR VOETEN OPTI 700 MICROSWITCH MET DRUKKNOP PAAR LUCHTKANALEN OPTI 760 DERDE ROOKAFREMMER OPTI 700-760 1/2 KIT GIETIJZER OPTI 780 1/2 KIT STENEN OPTI 760/700 Omschrijving GEMONTEERD THERMOCONTACT 2006 ELEKTRISCH KASTJE OPTI 780 INBOUW VARIATOR (Z.KABEL) OPTIFRE 780 KABELSET KIT VENTILATIE OPTI 700 - 760 - 16/9 (2006) 3Z VLAKKE KADER OPTI 760 4 ZIJ. KADER VLAK OPTI 760 3 ZIJ.GEBOGEN BEKL.KAD.OPTI 760 DK VENTILATOR DDL 133-200 AANZUIGROOSTER KOPER 25X16 kIT BARBECUE OPTI 780- OPTI 700 VENTILATIEKAST 750 M3 SPILDRAAIENDE KLEP OPTI 760-760 DK ONDERDEUR OPTIFIRE 783/2 Optifire 19 OPTIONS/RECHANGES/OPTIE/WISSELSTUKKEN OPTI 760 DF Pièces de rechange / wisselstukken Ref 01 01 01 02 03 04 05 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 22 23 24 25 26 27 28 ----------- Code 37B78017 27B78015 07RV1039 27660002 37B78016 27660000 37M76018 27M70026 27M76034 37B76034 37M76025 37B78009 37M76035 37B78008 37660016 37B78029 27B78014 37M76004 37116226 37117400 07FTS690 07FFIFG 07CB327 07VM0200 37M76032 37M76045 07CB352 07CB326 07CB354 37M76005 07BP03 37115018 07PBB049 07PBE001 37B78006 Description PORTE MONTEE OPTI 780 PLAT CONTREPORTE OPTI 780 PLAT CERAM. 656X487X4 OPTI 780 + OPTI 760 DF FERMETURE IF 96 DEFLECTEUR OPTI 780 PLAT ACCROCHE CLENCHE IF 96 CADRE 4 COTES OPTI 760 DF PORTILLON CADRE 4 C. OPTI 700 - 760 DF CACHE THERMOSTAT OPTI 760 DF PAIRE DE REPARTITEUR OPTI 760 CHICANE INFERIEURE OPTI 760 DF PORTE CENDRIER OPTI 780 CANAUX D'AIR OPTI 760 DF CENDRIER OPTI 780 SUPPORT BARREAU-CHENET IF 96 BARREAU PARE BUCHE OPTI 780 CAISSON CENDRIER OPTI 780 BRAS DECENDRAGE OPTI 760 DF FIXATION SONDE BUSELOT AIR CHAUD DIA 125 THERMOSTAT DIA90 TELESCOPIQUE SA-PAIRE GRILLES IF-GAUMAIS-POELE BRIQUE 120X60X30 BISEAUTEE BUSELOT RACCORD.CHEMINEE DIA 200 COMPENSATION CORPS CHAUFFE OPTI 760 DF CHICANE SUPERIEUR OPTI 760 DF BRIQUE 425X 150 X 30 BISEAUT.39/42% AL2O3 BRIQUE 150X60X30 BISEAUTEE BRIQUE REFRACT.220 X 60 X 30 CALE BRIQUE OPTI 760 DF MAIN FROIDE NICKEL.IF96+PRISMA TISONNIER POUSSOIR CADRE IF 60 VH SACLIPS PORTE CENDRIER D950207 SUPPORT GRILLES OPTI 780 Options / opties Ref 01 01 01 02 03 05 05 05 05 29 30 30 30 ----------------- Code 37B78025 37B78021 07RV1041 27B78022 37B78026 37M76011 27B78027 37M76020 27B78029 37B78023 37M76027 37M76007 27680052 37B77021 37660078 07EEG006 37680048 27660029 37M76021 37B78004 37660051 Description PORTE CINTRE MONTEE OPTI 780 CONTREPORTE MONTEE OPTI780 CIN CERAM.R.900 DEV.638 H.490 EP.4 FERMETURE PORTE CINTREE OPT780 DEFLECTEUR AIR OPTI 780 CINTRE CADRE 3 COTES PLAT OPTI 760 DF PORTILLON CADRE 3 C. OPTI 780 - 760 DF CADRE 3 COTES CINTRE OPTI 760 DF PORTIL.CINTRE CADRE 3C OPTI780 KIT VENTILATION OPTI 780 - 700 KIT CLAPET PIVOTANT OPTI 760 DF POIGNEE DE REGLAGE CLAPET PIVOTANT OPTI 700 -760 PALIER CLAPET PIVOTANT IF RC93 KIT VENTILATION 450 M3 KIT VARIATEUR blanc ENCASTRABLE IF96 SA - MICROSWITCH 831611 IW3 + 161L UL KIT THERMOCONTACT INFIRE RC93 KIT PARE BUCHE FONTE INFIRE 96 TRAVERSE 4 IEME COTE CADRE 3 COTES OPTI 760 DF BOITIER ELECTRIQUE OPTI 780 KIT THERMOCONTACT 2006 COMPLET Omschrijving VOLLEDIGE DEUR OPTI 760/1 TEGENDEUR OPTI 780 VLAK KERAM. 656X487X4 OPTI 780/760/760D SLUITING IF 96 LUCHTDEFLECTOR OPTI 780 VLAK HENDEL VANGER IF 96 4-ZIJDIGE KADER OPTI 760 DK AFDEKPLAAT4 Z KADER OPTI 700 - 760 DF THERMOSTAAT BESCHERMING OPTI 760 DK PAAR LUCHTVERDELERS OPTI 760 ONDERSTE ROOKAFREMMER OPTI 760DK ASLADE DEUR OPTI 780 LUCHTKANALEN OPTI 760DK ASLADE OPTI 780 STEUN BLOKKENHOUDER IF 96 BLOKKENHOUDER OPTI 780 ASLADE AFSLUITPLAAT OPTI 780 ROOSTERSTANG OPTI 760 DK BEVESTIGING HAARBUISJE WARMELUCHTBUISJE DIA 125 THERMOSTAAT Ø90 TELESCOPISCH VUURROOSTER INFIRE GAUMAIS-KACHEL VUURV.STEEN 120X60X30 KANTG. INOX AANSLUITINGSBUISJE DIA 200 VULSTUK VERBRANDINGSKAMER OPTI 760 DK BOVENSTE ROOKAFREMMER OPTI 760DK VUURV STEEN 425X150X30 KANTG 39/42% AL203 VUURV.STEEN 150X60X30 KANTG. VUURV STEEN 220 X 60 X 30 STEEN HOUDER OPTI 760 DK ZWARTE KOUDE HANDGREEP POOK KADER DRUKKNOP IF 60 VH VEERKLEM ASLADE DEUR ROOSTER SUPPORT OPTI 780 Omschrijving VOLLEDIGE DEUR OPTI 780/2 TEGENDEUR OPTI 780 ROND KERAM.R.900 DEV.638 H.490 EP.4 Opti 780 SLUITING GEBOGEN DEUR OPTI 780 LUCHTDEFLECTOR OPTI780 ROND 3Z VLAKKE KADER OPTI 760 AFDEKPLAAT3 Z KADER OPTI 780 - 760 DF 3 ZIJ.GEBOGEN BEKL.KAD.OPTI 760 DK ONDERDEUR OPTIFIRE 783/2 KIT VENTILATIE OPTI 700 - 760 - 16/9 (2006) SPILDRAAIENDE KLEP OPTI 760-760 DK REGELINGSHENDEL SPILDRAAIENDE KLEP OPTI 700-760 STEUN DRAAIENDE KLEP IF RC93 VENTILATIE KIT 750 M3 PHENIX KIT INBOUWDIMMER IF96 MICROSWITCH MET DRUKKNOP SET THERMOCONTACT RC93 KIT GIETIJZEREN BLOKKENHOUDER 96 ONDER 4DE ZIJDE 3Z KADER OPTI 760 DF ELEKTRISCH KASTJE OPTI 780 COMPLETE SET THERMOCONTACT 2006 Imprimé, le 11/09/2007 20 Opti- 4920 Harzé BELGIUM 06 EN 13229:2001 and EN 13229 A2:2004 Inset appliance fired by solid fuel Optifire 703/704 Mininum insulation thickness: Side wall: Back wall: Ceiling: Floor: Recommended fuels :Woodlogs Emission of CO in combustion products : 0.15 % Flue gas temperature : 296 °C Thermal output : 11.3 kW Energy efficiency : 75.9 % 111 mm minimum 113 mm minimum 89 mm minimum no insulation required Read and follow the operating instructions! Optifire 21 4920 Harzé BELGIUM 06 EN 13229:2001 and EN 13229 A2:2004 Inset appliance fired by solid fuel Optifire 760 D Mininum insulation thickness: Side wall: Back wall: Ceiling: Floor: Recommended fuels :Woodlogs Emission of CO in combustion products : 0.50 % Flue gas temperature : 245 °C Thermal output : 10,0 kW Energy efficiency : 68,6 % 103 mm minimum 113mm minimum 90 mm minimum 42mm minimum Read and follow the operating instructions! 22 Opti- 4920 Harzé BELGIUM 06 EN 13229:2001 and EN 13229 A2:2004 Inset appliance fired by solid fuel Optifire 763/764 Mininum insulation thickness: Side wall: Back wall: Ceiling: Floor: Recommended fuels :Woodlogs Emission of CO in combustion products : 0.25 % Flue gas temperature : 345 °C Thermal output : 15.9 kW Energy efficiency : 73.7 % 118 mm minimum 174 mm minimum 107 mm minimum no insulation required Read and follow the operating instructions! Optifire 23 5. Guarantee DURATION AND LIMITATION - 6 years guarantee on: the overall structure - 2 years guarantee on: removable parts - 2 years guarantee on: fans and speed variator - No guarantee on: glass, bricks AGREEMENT Bodart & Gonay guarantees its appliances: - in accordance with its catalogues and instructions for use, - for safety of operational use. RESERVES Bodart and Gonay reserves the right to modify its appliances, catalogues, instructions for use, independently, at any time, and without notice. The validity of the guarantee is annulled in the event of non-compliance with the requirements and recommendations in these instructions. Maintenance under guarantee will be carried out exclusively through the dealer on presentation of the purchase invoice. Parts will only be delivered in exchange for faulty parts. EXCLUSION Accidents, damage and malfunctions connected with: - Unsuitability of the rated power of the appliance for the heat requirements of the premises; - Incorrect installation or connections; - Destruction of the thermostat through overheating caused by intensive use through: • the ashtray door being left open; • the fan being left on stop; - Insufficient or excessive draught; - Misuse; - Incompatible, destructive and/or damp fuel (treated wood); - Consumption beyond limits of use; - Inadequate maintenance; - Use of electrical and electronic components not approved by Bodart and Gonay; - Any internal modification or alteration to the fireplace; - Transportation and installation. Transportation and packaging costs. Any costs not agreed in advance by Bodart & Gonay. Costs resulting from non-use of the appliance. EFFECTIVE DATE The guarantee takes effect from the date written on the invoice. The invoice is the sole authentic document for the guarantee. 24 Opti- Bodart & Gonay SA - Parc Artisanal de Harzé - Rue de Lambinon, 3 - B-4920 HARZE tel: 32 (0)4 239 93 93 - fax: 32 (0)4 239 93 98 [email protected] - www.b-g.be Installation Instructions Optifire 07DHOPFV2 Caution: Remove the instructions from the fireplace and give them to the client, along with the necessary instructions (explanations and demonstrations). 01.09 Optifire 24 INSTALLATION INSTRUCTIONS 1. Characteristics 2. Flue 3. Outside air supply 4. Convection air 5. Installation 5.1. Recommendations 5.2. Alcove 5.3. Electricity 5.4. Putting the fireplace in place 5.5. Frames 6. Options 6.1. Fan, speed variator, door- and temperature switch 6.2. Pivoting valve kit 26 32 33 33 34 34 35 35 35 36 37 37 39 Check list: Check the different minimum fitting dimensions (take options into account!) See p.17. Levelling the fireplace, 2 reference points. Position the chimney connection pipe and the hot air outlet connection. No combustible materials (wood, wallpaper, etc.) on the ceiling and on the walls around hot air outlets. For combustible materials on the floor, a safe distance of 80 cm is required. Combustion air circuit control. Convection air circuits control. The chimney outlet has a cowl. Installation of frame (option) before building work. 25 Optifire 1.Characteristics : 13.5 10 13.5 10 Optifire 703: Optifire 26 13.5 10 13.5 10 Optifire 704: 27 Optifire Ø ROOKUITLAAT: 200MM AANTAL WARMELUCHTUITLATEN: 4 X Ø 125MM HOUTVERBRUIK (maximale snelheid): 3.5KG/H GEWICHT: 139KG Ø SORTIE FUMEE: 200MM SORTIES AIR CHAUD: 4 X Ø 125MM CHARGE DE BOIS (allure maximum): 3.5KG/H POIDS: 139KG PROTECTION ELECTRIQUE: FUSIBLE 1.25 A TENSION ELECTRIQUE: 230 VAC PUISSANCE ELECTRIQUE: 77W ELECTRISCHE ZEKERING: 1.25 A AANSLUITING: 230 VAC ELECTRISCH VERMOGEN: 77W VETILATOR DEBIET 450M³/H BRANDSTOF(FEN): HOUT - KOLEN COMBUSTIBLES: BOIS - CHARBON DEBIT MAX 450M³/H VERMOGEN: 16.5KW MET VENTILATIE 12 KW ZONDER VENTILATIE OPTION VENTILATION: 1 TURBINE CENTRIFUGE PUISSANCE: 16.5KW AVEC VENTILATION 12 KW SANS VENTILATION REF:47M76... BODART & GONAY TYPE: OPTI 763/1 Optifire 763: Optifire 28 VENTILATIE OPTIE: 1 CENTRIFUGAAL TURBINE Ø ROOKUITLAAT: 200MM AANTAL WARMELUCHTUITLATEN: 4 X Ø 125MM HOUTVERBRUIK (maximale snelheid): 3.5KG/H GEWICHT: 139KG SORTIES AIR CHAUD: 4 X Ø 125MM CHARGE DE BOIS (allure maximum): 3.5KG/H POIDS: 139KG PROTECTION ELECTRIQUE: FUSIBLE 1.25 A TENSION ELECTRIQUE: 230 VAC PUISSANCE ELECTRIQUE: 77W ELECTRISCHE ZEKERING: 1.25 A AANSLUITING: 230 VAC ELECTRISCH VERMOGEN: 77W VETILATOR DEBIET 450M³/H BRANDSTOF(FEN): HOUT - KOLEN COMBUSTIBLES: BOIS - CHARBON Ø SORTIE FUMEE: 200MM DEBIT MAX 450M³/H VERMOGEN: 16.5KW MET VENTILATIE 12 KW ZONDER VENTILATIE OPTION VENTILATION: 1 TURBINE CENTRIFUGE PUISSANCE: 16.5KW AVEC VENTILATION 12 KW SANS VENTILATION REF:47M76... BODART & GONAY VENTILATIE OPTIE: 1 CENTRIFUGAAL TURBINE 29 Optifire TYPE: OPTI 764/1 Optifire 764: Optifire 763D: Optifire 30 Optifire 764D: 31 Optifire 2. Flue RECOMMENDATIONS The flue must be built according to good practice, the most important elements of which are as follows: - Minimum height (distance between connection and top of chimney stack) will be 4 m. - Section: chimney: Ø 200 air outlet: Ø125 - The flue must be heat insulated. - The chimney outlet (stack) and its location are very important; it is absolutely necessary that the outlet has a cowl to prevent rain reaching the fireplace. Ask advice from a chimney maker (any device contracting the section of the outlet must be avoided). The chimney outlet must be located away from areas affected by wind. Min 0,4 m - The presence of obstacles near the chimney outlet must be taken into account. -An individual flue does not have more than 2 catings (i.e. changes in direction). The angle of these cantings with the vertical generally speaking should not exceed 20°, or 45° for a smooth metal flue. 45° 20°- 45° OK! OK! - The flue must allow recovery of soot (sweepable). - Only connect one appliance per flue. FOR AN EXISTING FLUE: It is essential to check, in addition to air tightness, emptiness and overall stability, the compatibility of the fireplace and if necessary, line the flue, or even modify the chimneystack. Optifire 32 Airtight connection - In case of a double flue: - choose the best, - seal the unused one. Max 45° “Breeching” to prevent soot build-up Soot trap - In case of a side connection on an existing flue, carry out one of the following two assemblies: - It is essential that the connection is airtight. 3. Combustion air and outside air supply When a fireplace burns wood, it consumes air, which means that a certain quantity of air exits by the chimney D. This air must be compensated for by the normal inlets, A and B, and if the latter are insufficient, a new clean air inlet C must be added. The presence of a ventilator hood in the same living space creates an additional air outlet D’, which must also be compensated for. Indicative value of C in accordance with the diameter of the chimney and the air tightness of the house: You must provide a fresh air inlet of 30 cm²/KW, i.e. 150 cm2. A D D' B D - Preferably, this inlet will be near the fireplace. This is in order to avoid currents of cold air across the room, a vacuum in the premises and to help let fresh air in. 4. Convection air (hot air) Hot air produced by the fireplace leaves directly by the space above the door. However, it is possible to connect, in addition, 4 hot air pipes on the top of the fireplace. This allows even more heat to be extracted and/or the heat to be sent to a different room from the one where the fireplace is situated. The contribution of these outlets remains restricted to +/- 1 KW per outlet. Heat-insulated pipes are recommended for the appliance to work at its best (they create a «draught» for convection air). When installing these pipes, limit the length and changes in direction, bend at an angle at the widest change in direction and avoid the use of outlet grills with a low permeability coefficient, as the resulting losses in speed reduce the effectiveness of hot air outlets. 33 Optifire - If hot air is sent to another room, it is essential to fit an air return port with section at least equivalent to the hot air outlets. This is very important so as not to create a vacuum in the room, which would cause the fireplace to malfunction. - Convection air circuits must also be taken into account (see the convection diagrams below). OK! OK! 5. Installation 5.1. RECOMMENDATIONS - The chimney must be suitable. - To avoid losses of heat in the pipes, it is recommended that they be insulated. - The fireplace must be level. - Check that the door works properly (side opening). - After connection to the chimney, we advise you to light a fire. - It is possible not to insulate the fireplace at all. In this case, it is essential that air can circulate around the fireplace. To do this, an air stream of at least 5 cm must be provided right around the fire, which allows at the same time for heat to be recovered. The decorative chimney must then allow clean air to enter at the bottom and leave at the top. (See drawing in 5.2.) However if the fireplace is against one of the outside walls of the house, it is preferable to insulate it from this wall. - COMBUSTIBLE MATERIALS: they are to be prohibited in the immediate surroundings of the fireplace, hot air outlets and the chimney flue. A safe distance on the floor of 80 cm is required. Please note that when opening the door, burning embers can be projected several metres. - INSULATING MATERIALS: use «HIGH TEMPERATURE» materials like certain rock wools. In all cases, these materials must not be in contact with convection air (DO NOT USE GLASS WOOL). Optifire 34 5.2. Alcove B Y Y - Clear the way for connection to the chimney and, if necessary, the hot air pipes. - Remove any hoods and dampers. - Insulate the outside walls. - In the case of new building work, it is PROHIBITED to rest the building work on top of the fireplace. A --> B: System for decompressing and cooling the fireplace and chimney mantle. Recovery of additional heat. Z A Z --> Y and W: Natural or forced convection (with fan as option): Fireplace double wall recovery system. 5.3. Electricity - Bring the flexible power cable to face the port fitted in the appliance. Make sure there is enough length for the connection and for any subsequent simple maintenance. All installation and maintenance operations on the fan and the variator must be done with the power supply disconnected. 5.4. Putting the fireplace in place 1. Dismantle the removable parts. - the door (open more than 45°and lift) - the baffle (see dismantling a baffle) - the refractory bricks kit and grills 2. Introduce and position the fireplace in the alcove. - Clear the holes used for the convection circuit. - Determine the height (telescopic feet (except OPTI760 DF). CAUTION! Comply with the MINIMUM SECTION FOR CONVECTION AIR INDUCTION, i.e. 400cm² free passage, so take into account the passage coefficient of grills and filter if there are any. - Plan sufficient space for the fan if necessary. The fan can be mounted from inside the fireplace or from under the fireplace. - Heat insulate the outside adjoining wall and inflammable materials. - Put the appliance in place, upright and level (left/right and front/back). 35 Optifire - It is vital that the feet are pinned down. To do this, drill a 5.25 diameter hole with the bit provided and insert the M6 SELF-CUTTING screws (except OPTI760 DF). - Plan for passage of the motor electrical power cable when doing building work. - Connect the hot air collars if necessary. - Through the inside of the fireplace, look for the collar and pull it until it jams. Then pull down the bottom retainers. - Assembling the brickwork: firstly: the back – secondly: the sides. BRICKS REFERENES REFERENCE BRIQUES CAST IRON REFERENCES DIMENSIONS (mm) DIMENSIONS (mm) - Place the baffles in the most closed position but without backdraft to obtain the best yield from the fireplace. (See chapter 1.5. Adjusting baffles). - You are advised to do a test run before doing building work around the appliance. - Put the covering on the appliance (when designing the covering, do not forget to allow MINIMUM SECTIONS for passages of the CONVECTION CIRCUIT). - Place the covering frame. Simply slide the frame between the covering and the springs. - Dust the visible painted surfaces. - Make a first fire to bake the paint (ventilate the room and do not touch the fireplace). CHECK THE DRAUGHT. - If you need to alter the position of the baffles, note the ideal position of baffles for your chimney at the place given on the first page of these instructions. This will enable you to reposition them properly after chimney-sweeping. Note: Possibility of using the hooks for fastening the fireplace to its pallet to fasten the fireplace to the wall. 5.5. Frames Place the frame: 1. Open and unhinge the door. 2. Insert the frame in the cabinet. 3. Ideally, in terms of depth, the frame should be flush with the door. 4. Hang the door back on and close it. Optifire 36 6. Options 6.1. Fan, speed variator, door switch and temperature switch The fan enables you to pump air between the heating unit and the cabinet to recover maximum heat and thereby increase the yield and power of the appliance. The speed variator enables you to vary, according to requirements, the output of the fan. The door switch breaks contact when you open the door to prevent any backdraft of smoke and puffs of hot air during reloading of the fireplace in operation. Positioning the fan from below: Insert the fan (condenser, white cylinder, towards you) through the lower hole so that the platform rests on the bottom of the cabinet. Position the fan using silent blocs in the five housings provided. Be careful of the electrical cable. Positioning the fan from inside: You are advised to remove the finish frame and the door. The fan is inserted from inside; you must remove the pair of grills, the two stainless steel cases located in front of the grills, the bricks behind and at the side, and the grill support. Unscrew the ash box using the Allen key. The ash box is removed through the ashtray door after removing the ashtray. Make the electric connection. You must pass the fan connector through the orifice provided on the left of the ash box, position the switch support on the fireplace and screw it down. Connect the fan. Insert it in the fireplace (Pay attention to the fan’s assembly direction! Blower directed backwards). Check carefully the passage of the cable and connect the variator to the left of the fireplace. To finish, reassemble the fireplace. X Temperature switch The temperature switch automatically engages the fan when the appliance is hot and disengages it when it has cooled down. When switching on, a wait of about 15 minutes before it engages is normal. 37 Optifire OK ! 6.1. N°10 220V 220V IMPORTANT: Adjustment (calibration) of the speed variator: Once installation of the fan and the different components has been fully completed: - Turn on power. - Put the fan on minimum = knob turned fully in a clockwise direction. - Pull the knob (1) out. - Using a screwdriver, turn the adjustment screw (2) until the fan is operating silently; this determines the minimum output that you want on your fan. CAUTION: Always check carefully that the fan is always turning at least a little bit, even at reduced speed. Try several on/offs of the fan down to minimum to ensure that everything is operating smoothly. If the fan has stopped in minimum position, the fan motor will be damaged! 1. Speed adjustment knob. 1. 2. Minimum speed adjustment screw under the knob (calibration required). 2. 3. 1.25A fuse (Remove the knob, unscrew the plate, pull out and replace). 3. MAX. OFF= O MINI. For the power cable and position of the variator, simply measure the space required by the variator, cut the cable as required (unplugged!) and connect the variator to it as indicated in the diagram supplied with the variator. Optifire 38 6.2. Pivoting valve kit This kit enables you to seal, if required, the hot air stream above the door, sending more or less hot air to the hot air outlets if the latter are connected! 39 Optifire Bodart & Gonay SA - Parc Artisanal de Harzé - Rue de Lambinon, 3 - B-4920 HARZE tel: 32 (0)4 239 93 93 - fax: 32 (0)4 239 93 98 [email protected] - www.b-g.be