Shamir Autograph II Tech Brochure
Transcription
Shamir Autograph II Tech Brochure
As-Worn Technology™ Measurements 2. Pantoscopic Tilt Product Classification: Everyday> Progressive The angle of the lenses as they sit on a patient’s face. To get the maximum benefit from As-Worn Technology™, the actual measurements of the wearer should be included. (Vertex Distance Fitted and Refracted, Pantoscopic Tilt, Panoramic Angle) Natural Head Position Person 2 - Ear Lower Person 3 - Ear Higher Pantoscopic Tilt Range: 0 - 12 (Default: 9 ) If the As-Worn measurements are not included with the Autograph II® order, the Shamir Prescriptor® will use defaults. These defaults are based on averages. The consumer will benefit greatly from As-Worn Technology™, experiencing more precise and perfected vision. 3. Panoramic Angle The angle of the frame. 0˚ 1. Vertex Distance 15˚ 20˚ 25˚ 30˚ 35˚ 40˚ The distance between the person’s glasses and their eyes. 0˚ 0˚ 5˚ 5˚ 10˚ 10˚ 0˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚ 5˚ 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚ 5˚ 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚ Frame angle: 10° 0˚ 0˚ Vertex Range: 10mm - 16mm (Default: 13mm) 15˚ 20˚ 25˚ 30˚ 35˚Panoramic Angle 40˚ Wrap designs: 12 0˚ 5˚ 5˚ 10˚ 10˚ 0˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚ 5˚ 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚ 5˚ 10˚ Range: 0 - 12 (Default: - 30 (Default: 15 ) 15˚ 20˚ 25˚ 30˚ 5 35˚ ) 40˚ Frame angle: 22.5° 0˚ 0˚ 5˚ Example 10˚ These three patient measurements have been added to better interpret between the prescription derived from the phoropter and the prescription required by the doctor for the patient’s glasses. In order to take advantage of As-Worn Technology™, the following measurements are required: 1. Vertex distance (refracted and fitted): Vertex distance is the distance from the front of the eye to the back of the lens, whether it is in the phoropter or in the frame. 15˚ 20˚ R25˚ 30˚ L 35˚ 40˚ Sphere -4.25 -3.75 90 0˚ Sphere -3.78 -3.345 5˚ R 10˚ 15˚ L 20˚ 0˚ 15˚ 20˚ 25˚ 30˚ Height 35˚ 40˚ 5˚ 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚ Add +2.00 Pantoscopic Tilt: 10° 0˚ PD 31.0 31.5 Seg 17.5 17.0 Panoramic Angle: 6° 0˚ 5˚ 5˚ 10˚ 10˚ 0˚ 15˚ Cyl 20˚ -0.395 25˚ 30˚ -1.261 5˚ 10˚ 15˚ 20˚ 35˚ Axis 74.07 93.8 Add 1.582 +1.601 The above25˚example shows the Resultant Rx™ we’ll see 40˚ as the 25˚ prescribed Rx when worn in 30˚ with higher prescriptions benefit the most. 30˚ Clearly, those 35˚ 40˚ 15˚ 20˚ 25˚ 30˚ 35˚ the40˚ frame. 35˚ 40˚ Autograph II® w/As-Worn Technology™ Fitting Guide 11MM FIXED DESIGN 13MM FIXED DESIGN 15MM FIXED DESIGN 18MM FIXED DESIGN THE EFFECTS OF POSITION CHANGE POWERS: A powered lens moved away from the eye becomes more plus and more minus when moved closer. Lenses tilted change sphere and cylinder power. To test these, place a -4 sphere lens in an automated lensometer and change the position up and down on the lens stop or change the tilt and watch the prescription change. As a result, to deliver the correct prescription, lenses should be compensated to deliver the prescribed Rx. 15˚ 20˚ 25˚ 30˚ Axis 35˚ 40˚ -1.00 Resultant Rx™ 3. Panoramic angle: Panoramic angle, is the parabolic curve of the frame in relation to a flat plane (the curvature of the frame in relationship to the patient’s face). Therefore, the doctor’s prescription will be modified, taking the additional fitting requirements into account. The lab will return the glasses with two prescriptions; the original prescribed Rx and the “As-worn” Rx (a.k.a Resultant Rx™). It is important to use the Resultant Rx™ to verify the lens prescription in a lensometer. Some opticians may be concerned they are changing the doctor’s prescription. However, if a Rx is altered by the way it is worn, compensating the Rx for the wearing effects ensures the final pair of glasses actually delivers the prescription the doctor intended. 5˚ 10˚ Vertex Distance: 11.5mm (refracted at 13.5mm) 2. Pantoscopic tilt: Pantoscopic tilt is the angle of the frame to the face on the patient (in the phoropter this is zero for a frame 8 - 10mm). By supplying the complete frame and fitting data in addition to these parameters you are able to accurately deliver a personalized and superior lens to your patient as prescribed by the doctor for that specific frame. Cyl TECHNICAL INFORMATION 0˚ 5˚ 10˚ FIT AT 11 12 13 14 15 18 19 20 25 FIT AT 13 14 15 18 19 20 25 FIT AT 15 16 17 18 19 20 25 FIT AT 18 19 20 25 TRANSITION ZONE 6 6 6 6 6 6 6 6 6 TRANSITION ZONE 8 8 8 8 8 8 8 TRANSITION ZONE 10 10 10 10 10 10 10 TRANSITION ZONE 13 13 13 13 NEAR AREA 5 6 7 8 9 12 13 14 19 NEAR AREA 5 6 7 10 11 12 17 NEAR AREA 5 6 7 8 9 10 15 NEAR AREA 5 6 7 12 AU2-TEC-4PA-070512 As-Worn Technology Resultant Rx™ ™ Shamir Autograph II® ReCreating Perfect Vision® ReC ReCre ReCreating Perfect Vision® Perfect Vision® ReCreating ReC ReCre ® Vision ReCreating Perfect ReCreating Perfect Vision® ReCreating Perfect Vision ReC ReCre Transition Zone includes 4mm drop. Near Area: 8-10mm full add power, then decreases. * The calculations are approximates, there are other factors that may vary the actual values. Accommodative abilities, Total Rx and Add power will also have an effect on the final value. ReCreating Perfect Vision® www.shamirlens.com 877.514.8330 ® ® Shamir Autograph II Single Vision™ Shamir Autograph II - Single Vision™ is an aspheric lens. Its ocular surface is aspherically designed and processed with Freeform Technology™. This ensures an atoric ocular surface with enhanced optical and cosmetic properties. The lens will be laser engraved, these engravings are 34mm from center to center of the two laser engravings. The fitting point and the PRP (MRP) are located at the same position, directly between and in the center of the laser engravings. FITTING: A monocular PD and a fitting height should be taken for the Autograph II - Single Vision™ lens. This will ensure that the design is placed directly in front of the pupil. By design, the OC will not be at the fitting height, unless the fitting height is equal to the mechanical center of the frame. SURFACING: The lens should be blocked on geometric center and the fitting height and prism thinning should be specified. CHECKING POWER AND PRISM AFTER SURFACING: The laser engravings should be marked, and using the centration chart, the fitting point should also be marked. The power and the amount of prescribed prism, should there be any, are checked at the fitting point. Also, remember that the lens has been cosmetically balanced so there may be vertical prism here, similar to prism thinning in a progressive. The amount of prism ground to achieve this will not exceed 2.5 diopters and should be equivalent in each eye even if the powers are dissimilar. LAYOUT FOR EDGING: Shamir Autograph II ® Autograph II® is a Freeform® lens made at the lab. Freeform® lenses start from a single vision blank and are ground with precision using special machines. The design and the patient’s Rx are on the back of the lens. Our easy access diagram below explains everything. BACK SURFACE DESIGN WIDENS PATIENT’S FIELD OF VIEW. These lenses should be laid out for edging as if it were a progressive. The engraving marks should be on the 180 line and the fitting cross moved to correspond to the PD and Fitting Height. The OC should not be used for edging layout. FINAL INSPECTION: The lens should be treated like a progressive. The laser engravings are marked and the fitting point is marked. The PD is checked by measuring the distance between the fitting points (not the OC) the fitting height is measured from the fitting point. The power, Rx Prism and vertical imbalance are all checked at the fitting point. There will be prism thinning and there should be no vertical imbalance between the two eyes. Shamir Autograph II® Conventional Progressive Lens ORDERING THE SHAMIR AUTOGRAPH II - OFFICE™ LENS: 1. Provide the prescription the same way you do for a progressive lens. Total Dynamic Reduction 2. Provide the Fitting Height and Mono Distance PD. 3. Provide the Frame details - You can send either: • A frame • A drawing of the frame with the frame (A) frame (B) and frame ED and DBL • Box Measurements • Tracer files, if lab supports 4. Provide distance from patient’s eyes to computer screen (between 60cm-200cm with intervals of 1cm). R CR -129 FFO R 5. Provide “Eye Level” for the computer screen: -129 • Below Eye Level • Above Eye Level • At Eye Level Personal Dynamic Reduction • Static - primarily in one position (i.e. sitting) • In motion (i.e. standing) The chosen frame must have a minimum fitting height of 16mm and distance of minimum 7mm from the fitting point to the upper rim of the frame. The prescription range for total reading (distance and ADD) has to be between -6.0[D] to +8.0[D]. Eyeball While semi-finished molds suffer from slight degradations resulting in a loss of optical design, the same isn’t true for Autograph II®. Each Autograph II® lens is created from a Freeform® machine, right on the spot and not from a 20th century mold. The lens is also personalized to fit the patient’s needs and both the patient’s Rx and the optical design are on the back of the lens which opens up the fields of vision for the patient. Want more benefits? Autograph II® virtually eliminates unwanted astigmatism, swim and peripheral distortions providing maximized fields of vision. If you ask us, there’s no competition here. Autograph II - Office™ is a customized occupational lens designed with Shamir’s advanced progressive technology for patients requiring a wide intermediate and a wide near zone; it is specifically created for visual needs in a small environment setting - such as an office. Autograph II - Office™ is individualized by capturing a patient’s distinctive measurements including pupillary distance, refraction, and the measured distance of a patient’s workspace. Lens designers input this data into Shamir’s Prescriptor® software to determine the ideal power configuration for each wearer. Produced with EyePoint Technology®, the lens eliminates peripheral aberrations and visual distortions while providing smooth transitions between the power zones. 6. Provide “Work Conditions”: Shamir Autograph II® Conventional Progressive Lens Shamir Autograph II - Office™ Fitting Point (PRP) Verify: • You should only verify the lens at the near reading zone. • At the Total Dynamic Reduction, point 6 - 8mm above the fitting cross, you can find the reading prescription which will be approximate power of the Total Dynamic Reduction from the total reading power. • The invisible markings will include the patient’s personal dynamic reduction. Example: Reading prescription: +2.00[D] Dynamic Reduction: -1.71[D] Center of C: +0.29[D] +0.29 [D] R CR -171 FFO Fit: Fit the Shamir Autograph II - Office™ the same way as a progressive lens, with the fitting cross at the pupil center while the patient looks at the distance and distance PD. ReCreating Perfect Vision® -1.71[D] +2.00 [D]
Similar documents
Shamir Autograph III®
is located in the most optimal position for your eyes. We can determine where the best position for the reading area is in your lenses based on your Rx. This means no more shifting and moving your ...
More information