Fiber Optic Cable for the Nuclear Power Industry

Transcription

Fiber Optic Cable for the Nuclear Power Industry
2014
Fiber Optic Cable for
the Nuclear Power Industry
Partnership
RSCC Wire & Cable LLC (Rockbestos Surprenant Cable Corporation) and AFL entered
into a partnership for the development of fiber optic cables and releated components
into the resurging nuclear power market in early 2010. Both companies have a long
history of supplying specialty cables into utility and harsh environments where high
levels of reliability are vital. Even prior to the agreement, the partnership was already
impacting the nuclear cable market with new developments including specialty radiation
resistant fiber, highly flame retardant cables, and the development of Thermoset Low
Smoke Zero Halogen jacketed fiber optic cables for indoor/outdoor use.
RSCC brings extensive knowledge of polymers specifically designed for utilization in
radiation and harsh environments. As a world leader in the design and manufacture of
insulated high performance control, power, instrumentation, and specialty cables to the
nuclear marketplace, RSCC is unparalleled in their harsh environment test capabilities.
RSCC has over 40 years of nuclear experience and an NUPICS audited 10CFR 50
Appendix B QA program. In addition, RSCC is a nuclear cable supplier with ISO 9001
and NQA-1 approvals.
AFL is an industry leader in providing fiber optic products, engineering expertise
and integrated services to the data, utilities, and specialty markets. Over 30 years
of fiber optic cable experience enables AFL to provide effective fiber optic solutions
and engineering support. AFL’s optical fiber capability and specialty cable manufacturing,
combined with RSCC’s comprehensive knowledge of radiation and harsh environment
resistant polymers, fills an essential need for the nuclear industry in the digital
age. RSCC-AFL is committed to meeting our customers’ requirements through
collaborative efforts in pursuit of innovation, manufacturing excellence, and
unrivaled customer service.
www.R-SCC.com or (860) 653-8300
© 2011, AFL, all rights reserved. Revision 0, 01.12.11
Specifications are subject to change without notice.
Table of Contents
Fiber Optic Cable
Armored Harsh Environment Cable. . . . . . . . . . . . . . . . . . . . . . . . 2
Low Smoke Zero Halogen (LSZH), Indoor/Outdoor Loose Tube
Cable with Thermoset Jacket. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Indoor/Outdoor, Low Smoke Zero Halogen (LSZH) Breakout Cable. . 5
Low Smoke Zero Halogen Distribution Cable. . . . . . . . . . . . . . . . . 7
PVDF Jacketed, Plenum Distribution Cable. . . . . . . . . . . . . . . . . . . 9
Deployable Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Fiber Optic Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Fusion Splicing
FSM-60S Fusion Splicer Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Test and Inspection
C860 QUAD OTDR and Certification Test Kit . . . . . . . . . . . . . . . . 16
OFS 300 Optical Microscope. . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
DFS1 Digital FiberScope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
VFI2 and HiLite Visual Fault Identifiers. . . . . . . . . . . . . . . . . . . . . 25
SMLP5-5 Test Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
M210 Multifunction Micro OTDR . . . . . . . . . . . . . . . . . . . . . . . . 28
Cleaning Supplies
One-Click Cleaner Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Cletop Cassette Cleaner Series. . . . . . . . . . . . . . . . . . . . . . . . . . 32
www.R-SCC.com or (860) 653-8300
1Q13
11
Armored Harsh Environment Cable
Armored Harsh Environment cables utilize AFL’s patented, laser welded tube to technology
which provide a hermetically sealed package for the optical fibers within. The armor
wires provide improved crush and tensile performance while enabling cable flexibility.
316 stainless steel wires provide strong corrosion resistance. PVC free, flame retardant
jackets are available to provide additional long term corrosion and chemical resistance.
Users can select gel-filled or gel-free tubes. Gel is useful in preventing water migration for
outdoor applications. For indoor applications, gel can be used, but is not required.
Armored Harsh Environment cables can be used in a variety of applications including
those which require survivability and signal integrity during significant harsh environment
generating events.
These cables can be designed and tested for Class 1E safety related functions under an
Appendix B and NQA-1 quality assurance program.
Cable Components
Optional Outer Jacket
Armor Wires
Shown with optional outer jacket
Stainless Steel Tube
Features
• Hermetic Stainless Steel Tube
• High Strength Wire
• Jacket Options
• Gel Options
•Flexible
•Rugged
Applications
• Tamper Resistant Campus
Communication Cable
•In-Containment
• MSIV and Piping Penetration rooms
• High Pressure and Temperature
• Flooded spaces
• Hazardous chemical areas
Environmental Performance
• Available with a wide variety of jacketing materials including:
– Thermoplastic LSZH
– Thermoset LSZH
–PVDF
Optional Gel
Fiber
String Binders (2)
Designed to Meet the
Following Industry Standards
• IEEE 383-1974
• IEEE 1202
• Plenum, riser requirements met
dependent on jacket seletion
• ICEA S-83-596 (premise- indoor)
• ICEA S-104-696 (indoor/outdoor)
• ICEA S-87-640 (outdoor)
Temperature Performance
JACKET
TYPE
None
None
FIBER COATING
TYPE
Acrylate
High Temp.
Acrylate
None
Polyimide
Thermoset LSZH High Temp.
Acrylate
TEMP.
RATING
(°C)
-40 to +85
-40 to +150
-40 to +300
-25 to +90
NOTE: Other jacket types and fiber coatings available.
Mechanical Data
JACKET
TYPE
None
None
None
None
Thermoset LSZH
Thermoset LSZH
Thermoset LSZH
Thermoset LSZH
FIBER
COUNT
2,4
6, 8,12
24, 36
48, 72
2, 4
6, 8,12
24, 36
48, 72
www.R-SCC.com or (860) 653-8300
TUBE O.D. STRANDED CORE O.D.
in (mm)
in (mm)
.051 (1.3)
.083 (2.1)
.094 (2.4)
.142 (3.6)
.125 (3.2)
.205 (5.2)
.150 (3.8)
.230 (5.8)
.051 (1.3)
.083 (2.1)
.094 (2.4)
.142 (3.6)
.125 (3.2)
.205 (5.2)
.150 (3.8)
.230 (5.8)
JACKET O.D.
in (mm)
­—
—
—
—
.142 (3.6)
.197(5.0)
.285 (7.3)
.315 (8.0)
WEIGHT
lbs/1000ft (kg/km)
11 (16)
30 (45)
68 (101)
81 (121)
88 (25)
198 (56)
427 (120)
510 (144)
© 2011, AFL, all rights reserved. Revision 0, 01.12.2011
Specifications are subject to change without notice.
2
Low Smoke Zero Halogen (LSZH),
Indoor/Outdoor Loose Tube
Cable with Thermoset Jacket
Features
• Fiber counts up to 144
• Low smoke zero halogen, thermoset jacket
• Optional rodent resistant
armor available
• Resistant to lubricating oil
(Mil-L-23699), hydraulic fluid
(Mil-H-5606), gasoline and
deionized water
• NEC OFNG-LS listed
• NEC OFCG-LS listed
(steel armor option)
• Minimizes the use of PVC
consistent with guidance of
NRC Regulatory Guide 1.189
“Fire Protection for Operating
Nuclear Power Plants”
• Gel-filled tubes provide maximum
water-blocking capabilities to
protect fibers
• Cross-linked, cable jacket melt
resistance exceeds 200°C
• Suitable for cable tray installation
Utilizing a thermoset (XLPO) jacket, RSCC-AFL’s LX-series low-smoke zero-halogen
(LSZH) loose tube cables are specifically designed for industrial environments.
Ideal for indoor and outdoor applications, the cable design includes dry-core water
blocking system, SZ-stranding for easy mid-span access to fibers, and a highly chemical
resistant, cross-linked, UV-resistant outer jacket. For even greater mechanical strength,
a corrugated steel armor version is available. In addition to compliance to IEEE 383
flame testing, the OFN-LS listing provides additional third party testing and assurance
that the cable family meets the minimum flame and smoke generation guidelines for
cable tray installation and other general purpose inside building applications.
Cable Components
FRP central member
water blocking layer
strength member
XLPO flame retardant LSZH jacket
buffer tube with gel or optional dry water-blocking elements
optical fibers
optional inner jacket and steel armor
rip cord
Maximum Lengths
SINGLE-MODE
feet
meters
23,000
7,000
FIBER
COUNT
2 - 144
MULTIMODE
feet
23,000
meters
7,000
Longer lengths may be available upon request.
Testing Standards
Temperature Range
ANSI/ICEA S-104-696
Operating . . . . . . . . - 40ºC to + 70ºC
Telcordia GR-20
Storage . . . . . . . . . - 50ºC to + 75ºC
IEEE 383-1974, 2003
IEEE 1202
Installation. . . . . . . - 20ºC to + 60ºC
Crush*
Armored . . . . . . 550 N/cm (375 lbs/in)
Non-armored . . . 440 N/cm (250 lbs/in)
* Standard loose tube cables are 220 N/cm (125 lbs/in)
continued on next page –>
© 2011, AFL, all rights reserved. Revision 1, 03.31.2014
Specifications are subject to change without notice.
www.R-SCC.com or (860) 653-8300
3
Low Smoke Zero Halogen (LSZH),
Indoor/Outdoor Loose Tube Cable with
Thermoset Jacket
Ordering Information
ITEM
NUMBER
FIBER
COUNT
NOMINAL DIAMETER
inches
mm
NUMBER OF
TUBES/FIBERS
NON-ARMORED (OFNG-LS) – (92 & 144 fiber Count OFN-LS)
6
1w/6 (4 fillers)
0.47
RSLX006C5101N1
12
1w/12 (4 fillers)
0.47
RSLX012C5101N1
24
2w/12 (3 fillers)
0.47
RSLX024C5101N1
36
3w/12 (2 fillers)
0.47
RSLX036C5101N1
48
4w/12 (1 filler)
0.47
RSLX048C5101N1
60
5w/12 (no fillers)
0.47
RSLX060C5101N1
72
6w/12 (no fillers)
0.53
RSLX072C6101N1
96
8w/12 (no fillers)
0.57
RSLX096C8101N1
144
12w/12(no fillers)
0.724
RSLX144CC101N1
ARMORED (OFCG-LS)
6
1w/6 (4 fillers)
0.60
RSLX006C5111S1
12
1w/12 (4 fillers)
0.60
RSLX012C5111S1
1w/12,1w/6
(3
18
0.60
RSLX018C5111S1
fillers)
24
2w/12 (3 fillers)
0.60
RSLX024C5111S1
2w/12,1w/6
(2
30
0.60
RSLX030C5111S1
fillers)
36
3w/12 (2 fillers)
0.60
RSLX036C5111S1
48
4w/12 (1 filler)
0.60
RSLX048C5111S1
60
5w/12 (no fillers)
0.60
RSLX060C5111S1
72
6w/12 (no fillers)
0.63
RSLX072C6111S1
NOMINAL WEIGHT
lbs/1,000 ft
kg/km
MAX. TENSILE LOAD - lbs (N)
Short Term
Long Term
MIN. BEND RADIUS - in (cm)
Short Term
Long Term
11.9
11.9
11.9
11.9
11.9
11.9
13.5
14.5
18.4
92
92
91
91
90
90
105
121
226
137
137
136
136
134
134
156
180
336
600 (2670)
600 (2670)
600 (2670)
600 (2670)
600 (2670)
600 (2670)
600 (2670)
600 (2670)
600 (2670)
180 (800)
180 (800)
180 (800)
180 (800)
180 (800)
180 (800)
180 (800)
180 (800)
180 (800)
9.4 (24)
9.4 (24)
9.4 (24)
9.4 (24)
9.4 (24)
9.4 (24)
10.6 (27)
11.4(29)
14.48(36)
4.7 (12)
4.7 (12)
4.7 (12)
4.7 (12)
4.7 (12)
4.7 (12)
5.3 (13.5)
5.7(14.5)
7.24(18)
15.2
15.2
129
131
192
194
600 (2670)
600 (2670)
200 (890)
200 (890)
12.4 (32)
12.4 (32)
6.2 (16)
6.2 (16)
15.2
132
196
600 (2670)
200 (890)
12.4 (32)
6.2 (16)
15.2
132
196
600 (2670)
200 (890)
12.4 (32)
6.2 (16)
15.2
132
196
600 (2670)
200 (890)
12.4 (32)
6.2 (16)
15.2
15.2
15.2
16.1
132
132
132
153
196
197
198
228
600 (2670)
600 (2670)
600 (2670)
600 (2670)
200 (890)
200 (890)
200 (890)
200 (890)
12.4 (32)
12.4 (32)
12.4 (32)
13.0 (33)
6.2 (16)
6.2 (16)
6.2 (16)
6.5 (17)
 Fiber Types-Replace asterisk () in part number with number corresponding to desired fiber type below. Diameter and weight subject to change without notice.
(D) at end of item number indicates gel-free, dry water-blocked buffer tubes. Example: RSLX0129C5101N1(D)
Optical Performance Information
FIBER TYPE
Grade-index Multi-mode Fibers
(6) 62.5 Giga-Link 300
(8) 62.5 Giga-Link 1000
(5) 50 Giga-Link 600
(L) 50 Laser-Link 300 (OM3)
(1) 100/140 Graded Index MM Fiber
Step-index Singlemode Fibers
(9) Singlemode
(K) Futureguide SR-15e Bend Insensitive
(AL) Radiation Resistant Singlemode
OVERFILLED LAUNCH
MINIMUM BANDWIDTH (MHz•km)
MAXIMUM ATTENUATION
(dB/km)
1300
850 nm
nm
1310 nm 1550 nm
1 GIGABIT ETHERNET
MINIMUM LINK DISTANCE
(meters)
850 nm
1300 nm
850 nm
1300 nm
10GIGABIT ETHERNET
MINIMUM LINK DISTANCE (meters)
850 nm
1300 nm
(serial)
(serial)
3.2
3.2
2.9
2.9
5.0
1.2
1.2
0.9
0.9
4.0
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
200
350
500
1500*
100
600
600
500
500
100
300
500
600
900
N/A
550
1,000
600
550
N/A
32
65
82
300
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0.35
0.35
0.25
0.25
N/A
N/A
N/A
N/A
N/A
N/A
5,000
5,000
N/A
N/A
10,000
10,000
N/A
N/A
0.35
0.25
N/A
N/A
N/A
5,000
N/A
10,000
* 50/125 Laser-Link 300 Effective Modal Bandwidth = 2000 MHz/Km in 850nm window for 10 Gigabit Ethernet Links as measured by Differential Mode Delay (DMD).
• Gigabit Ethernet Link Distance are based on modal dispersion constraints. Actual link distance limits may also be constrained by attenuation, depending on customer’s specific loss budget.
• Available with specialty fibers (ex. 200/230, specialty coatings, radiation hardened options). Consult with our engineering specialists to select the best fiber for your application.
© 2011, AFL, all rights reserved. Revision 1, 03.31.2014
Specifications are subject to change without notice.
www.R-SCC.com or (860) 653-8300
4
Indoor/Outdoor, Low Smoke Zero Halogen
(LSZH) Breakout Cable
Features
• Semi-pressure extruded, flame
retardant, LSZH jacket resistant
to fungus, water and UV
• Minimizes use of PVC
consistent with NRC Regulatory
Guide 1.189
“Fire Protection for Operating
Nuclear Power Plants”
• Each fiber in 2.4 mm subcable for
added mechanical protection and
higher strength terminations
• NEC OFNR-LS Listed
• Aramid between subcables and outer
jacket provides additional strength
• Crush Resistance:
2200 N/cm (1500 lbs/in) (EIA-455-41A)
• Impact Resistance:
1500 impacts at 2.94 N-m (EIA-455-25)
• Flex Cycles: 400 Cycles (EIA-455-104)
• Subcables numbered every 6 inches
• Meets or exceeds:
- ANSI/ICEA S-104-696
(Indoor/Outdoor)
- Telcordia GR-409 (General
Purpose, Horizontal Backbone
Cable, Weatherized)
- IEC 60794-2-21 (I/O Multi-Fiber
Distribution)
• Subcables meet Telcordia GR-409
interconnect requirements
• Water blocked core & subunits meets water penetration requirements
of IEC 60794-1-2
LSZH Breakout Cables are the product of choice for indoor and outdoor industrial
applications where increased resistance to cyclic flex, compressive forces (crush),
impact or higher tensile loads are desirable. In accordance with NRC regulatory
guidance, this cable design features a complete absence of PVC and other halogenated
polymers which have the potential to create an “acid rain” effect when sprinklers
interact with smoke during a fire, thus undermining the potential reliability of other
equipment throughout an affected power plant space. LSZH Breakout cables are
highly flame retardant and meet nuclear, industrial and NEC general purpose flame
and smoke test requirements. Each fiber is protected by 2.4 mm sub-cable which can
be “broken-out” from the cable at key equipment junctures. Aramid yarn strength
members in each sub-cable allow each fiber to be terminated in a way that protects
the fiber from strain during mate-demate cycles, tension or bending at the back of
the connector. This is highly desirable for long term connection assembly reliability.
Additional aramid yarn strength members are coupled between sub-cables and the
semi-pressure extruded outer jacket for better installation strength and for better
strain relief when this rugged cable is used with round, military style, hermaphroditic
connectors that are often specified for harsh environment connections. The resulting
LSZH breakout cable provides the best blend of features for long term fiber optic link
reliability within power plant environments.
Cable Components
2-Fiber
6-Fiber
Mechanical Data
PART NUMBER
RSBE002242##E
RSBE004242##E
RSBE006242##E
RSBE008242##E
RSBE012242##E
RSBE018242##E
RSBE024242##E
FIBER
COUNT
NOMINAL
DIAMETER
Inches
(mm)
WEIGHT
lbs/1000ft
(kg/km)
Installation
Long Term
Installation
Long Term
2
4
6
8
12
18
24
0.34 (8.6)
0.34 (8.6)
0.4 (10.2)
0.46 (11.7)
0.58 (14.8)
0.59 (15)
0.66 (16.8)
50 (75)
50 (75)
73 (108)
95 (141)
153 (228)
138 (206)
183 (273)
300 (1350)
300 (1350)
600 (2700)
600 (2700)
600 (2700)
600 (2700)
600 (2700)
100 (450) 6.8 (17.2)
100 (450) 6.8 (17.2)
200 (900) 8.0 (20.4)
200 (900) 9.2 (23.4)
200 (900) 11.6 (29.6)
200 (900) 11.8 (30)
200 (900) 13.2 (33.60)
3.4 (8.6)
3.4 (8.6)
4.0 (10.2)
4.6 (11.7)
5.8 (14.8)
5.9 (15.0)
6.6 (16.8)
 Please specify fiber type when ordering (see next page)
TENSION
lbs (N)
BENDING RADIUS
inches (cm)
## - Specify jacket coloring scheme when ordering:
22 = Orange outer jacket, Orange subunits
99 = Yellow outer jacket, yellow subunits.
82 = Black outer jacket, Orange subunits (standard for Multimode)
89 = Black outer jacket, Yellow subunits (standard for singlemode)
8C = Black outer jacket, aqua subunits (Standard for Laser-Link 300)
Subunits are printed every 6” with unit number
© 2011, AFL, all rights reserved. Revision 2, 6.6.2013
Specifications are subject to change without notice.
www.R-SCC.com or (860) 653-8300
5
Indoor/Outdoor, Low Smoke Zero Halogen (LSZH) Breakout Cable
Applications
Testing Standards
• Building Risers
• Cable Trays
• General Purpose Industrial
• Tunnels
• Nuclear Power Plants
• Outdoor Buried (Duct Installation)
IEEE 383
IEEE 1202
OFNR-LS
UL-1666
Temperature Range
IEC 60332-24
IEC 60754-1 & 2
IEC 61034-2
Operating . . . . . . . . . -40º to + 70ºC
Storage . . . . . . . . . . -40º to + 70ºC
Installation. . . . . . . . -20º to + 70ºC
Optical Performance Information
FIBER TYPE
Grade-index Multi-mode Fibers
(6) 62.5 Giga-Link 300
(5) 50 Giga-Link 600
(L) 50 Laser-Link 300 (OM3)
(1) 100/140 Graded Index MM Fiber
Step-index Singlemode Fibers
(9) Singlemode
(K) Futureguide SR-15e Bend
Insensitive
(AL) Radiation Resistant Singlemode
OVERFILLED LAUNCH
MINIMUM BANDWIDTH (MHz•km)
MAXIMUM ATTENUATION
(dB/km)
1300
850 nm
nm
1310 nm 1550 nm
1 GIGABIT ETHERNET
MINIMUM LINK DISTANCE
(meters)
850 nm
1300 nm
850 nm
1300 nm
10GIGABIT ETHERNET
MINIMUM LINK DISTANCE (meters)
850 nm
1300 nm
(serial)
(serial)
3.5
3.5
3.5
5.0
1.2
1.2
1.2
4.0
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
200
500
1500*
100
600
500
500
100
300
600
900
N/A
550
600
550
N/A
32
82
300
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0.5
0.5
0.5
0.5
N/A
N/A
N/A
N/A
N/A
N/A
5,000
5,000
N/A
N/A
10,000
10,000
N/A
N/A
0.5
0.5
N/A
N/A
N/A
5,000
N/A
10,000
* 50/125 Laser-Link 300 Effective Modal Bandwidth = 2000 MHz/Km in 850nm window for 10 Gigabit Ethernet Links as measured by Differential Mode Delay (DMD).
• Gigabit Ethernet Link Distance are based on modal dispersion constraints. Actual link distance limits may also be constrained by attenuation, depending on customer’s specific loss budget.
• Available with specialty fibers also (ex. 200/230, specialty coatings, radiation hardened options). Consult with our engineering specialists to select the best fiber for your applications.
Cable Length - Reel Size
ITEM
Reel Height (inches)
Reel Outside Width (inches)
Drum Diameter (inches)
Reel Weight (lbs)
CAPACITY: meters (feet)
2/4 Fiber Breakout
6 Fiber Breakout
8 Fiber Breakout
12 Fiber Breakout
24 Fiber Breakout
REEL E
34
20
24
48
REEL F
42
36
23
148
1,300 (4,261)
1,000 (3,280)
—
1,000 (3,280)
­
—
2,500 (8,200)
2,500 (8,200)
2,500 (8,200)
1,600 (5,250)
1,300 (4,261)
© 2011, AFL, all rights reserved. Revision 1, 3.5.2013
Specifications are subject to change without notice.
www.R-SCC.com or (860) 653-8300
6
Low Smoke Zero Halogen Distribution Cable
LSZH Distribution cables are economical, multi-purpose cables for running fiber cable
between communications closets and equipment rooms, where fibers are terminated in
distribution enclosures. Use of flame retardant polyethylene eliminates the use of PVC
and other halogenated compounds, consistent with the guidance of NRC Regulatory
Guide 1.189. Additionally, this cable family’s OFNR-LS listing makes it suitable for
installation in a wide variety of spaces including building risers. Generally this cable will
be run in protected raceways and conduit, while more robust cables like the Indoor/
Outdoor Loose Tube cable and Breakout Cables are suited for industrial facility cable
tray deployment. The cable offers nuclear facilities an affordable method for supporting
in-building data communications links outside of the nuclear island, while using a cable
which exceeds telecommunciations industry standards for indoor fiber optic cables and
guidance from the NRC.
Cable Components
Features
Applications
• Flame Retardant, LSZH jacket
• Minimizes use of PVC consistent
with NRC Regulatory Guide 1.189
“Fire Protection for Operating
Nuclear Power Plants”
• OFNR-LS listed
• ROHS/REACH SVHC compliant
• Routing between communications
closets and equipment rooms
• Data Center Trunk cabling
• LAN distribution /
intrabuilding backbones
Temperature Range
Testing Standards
Operating
Storage
Installation
UL1666, UL1685 (OFNR-LS listed)
IEEE 383
IEEE 1202
IEC 60332-24
IEC 60754-1&2
IEC 61034-2
-20 C to +70 C
-40 C to +70 C
-10 to to +60 C
Mechanical Data
CABLE
TYPE
QUAD-Link
CPC
PART NO.
LSZH
FIBER
COUNT
TENSION
BENDING RADIUS
LBS (N)
INCHES (CM)
NOMINAL
DIAMETER
WEIGHT
INCHES
(MM)
LBS/
1000 FT
(KG/KM)
INSTALLATION
LONG
TERM
INSTALLATION
LONG
TERM
RSUE004482#0E
4
0.189 (4.8)
14 (21)
200 (890)
45 (198)
3.8 (9.6)
1.9 (4.8)
RSCE006522#0E
6
0.205 (5.2)
17 ( 26)
200 (890)
45 (198)
4.1 (10.4)
2.1 (5.2)
RSCE008542#0E
8
0.213 (5.4)
19 (29)
200 (890)
45 (198)
4.3 (10.8)
2.2 (5.4)
RSCE012602#0E
12
0.236 (6.0)
26 (38)
200 (890)
45 (198)
4.8 (12.0)
2.4 (6.0)
RSCE018762#0E
18
0.299 (7.6)
39 (58)
300 (1320)
90 (396)
6.0 (15.2)
3.0 (7.6)
RSCE024822#0E
24
0.331 (8.4)
50 (75)
300 (1320)
90 (396)
6.5 (16.4)
3.3 (8.2)
 Please specify fiber type when ordering (see below)
5 = 50/125 µm multimode GIGA-Link™ 600
7 = 50/125 µm multimode GIGA-Link™ 2000
6 = 62.5/125 µm multimode GIGA-Link™ 300
8 = 62.5/125 µm multimode GIGA-Link™ 1000
9 = 9/125 µm single-mode
L = 50/125 µm multimode Laser-Link 300 for 10 Gigabit Ethernet
K = Single-mode Futureguide SR-15e Bend Insensitive
Contact Customer Service for special fiber types/performance needs.
www.R-SCC.com or (860) 653-8300
# Specify jacket color when ordering
2 = Orange (standard for multimode)
8 = Black
9 = Yellow (standard for singlemode)
C = Aqua (standard for Laser-Link 300
© 2013, AFL, all rights reserved. PP-10-00001. Revision 0, 5.20.13
Specifications are subject to change without notice.
7
Low Smoke Zero Halogen Distribution Cable (cont.)
Specifications
CORE SIZE/ FIBER TYPE
MAXIMUM ATTENUATION (DB/KM)
ISO/
IEC
OVERFILL LAUNCH MIN.
BANDWIDTH (MHZ•KM)
EMBc
(MHZ•KM)
GIGABIT ETHERNET MIN.
LINK DISTANCE
(METERS)
850 NM
1300 NM
300
550
10 GIGABIT ETHERNET
MIN. LINK DISTANCE
(METERS)
850 NM
1300 NM
32
­—
850 NM
3.5
1300 NM
1.2
1550 NM
N/A
850 NM
200
1300 NM
600
N/A
(8) 62.5 Giga-Link™ 1000 OM1
(5) 50 Giga-Link™ 600
OM2
3.5
1.2
N/A
350
600
N/A
500
1000
65
—
3.5
1.5
N/A
500
500
N/A
600
600
82
—
(L) 50 Laser-Link 300
OM3
3.0
1.2
N/A
1500
500
2000
1000
550
300
—
(K) SM Futureguide
SR-15e Bend Insensitive
(ITU G. 657.A)
(9) SM
OS2
N/A
0.5
0.5
N/A
N/A
N/A
N/A
5000
N/A
10,000
OS2
N/A
0.5
0.5
N/A
N/A
N/A
N/A
5,000
N/A
10,000
(6) 62.5 Giga-Link™ 300
OM1
Tested to meet or exceed EIA/TIA 568-B3 / Telcordia GR-409-CORE
Maximum Cable Length - Reel Size
ITEM
REEL A
REEL B
REEL C
Reel Height (inches)
16
24
30
REEL D
34
Reel Outside Width (inches)
15
17
15.25
21.25
Drum Diameter (inches)
8
12
12
12
Reel Weight (lbs)
10
23
34
44
4 Fiber Quad-Link
1,000 (3,281)
3,200 (10,500)
5,000 (16,404)
—
6 Fiber CPC
1,200 (3,937)
3,800 (12,467)
5,000 (16,404)
—
8 Fiber CPC
1,000 (3,281)
3,200 (10,500)
5,000 (16,404)
—
12 Fiber CPC
800 (2,625)
2,400 (7,874)
4,000 (13,123)
5,000 (16,404)
18 Fiber CPC (single unit)
—
1,300 (4,265)
2,100 ( 6,890)
3,350 (11,000)
24 Fiber CPC (single unit)
—
1,000 (3,281)
1,700 ( 5,777)
3,150 (10,335)
CAPACITY: METERS (FEET)
www.R-SCC.com or (860) 653-8300
© 2013, AFL, all rights reserved. PP-10-00001. Revision 0, 5.20.13
Specifications are subject to change without notice.
8
PVDF Jacketed, Plenum Distribution Cable
PVDF Jacketed Distribution Cables are economical, multi-purpose, robust cables for
running longer lengths of fiber cable between distribution enclosures throughout an
industrial facility. Use of PVDF (fluoropolymer) jacket minimizes the use of PVC, consistent with the guidance of NRC Regulatory Guide 1.189, while providing a high level of
resistance to stretching, tear, abrasion, moisture and chemicals. Despite the rugged feel
of the cable, it maintains a high degree of flexibility. The cable is plenum listed and can
be used in any space requiring flame spread and limited smoke generation requirements
including plenum spaces, building risers, cable trays and general purpose industrial installations. Waterblocking strength members and a UV/fungus/moisture resistant outer
jacket make the cable suitable for installation in conduit betweeen buildings when the
conduit depth or outdoor temperatures prevent cables exposure < -20 deg C.
Cable Components
Features
Testing Standards
NFPA 262 (OFNP listed)
IEEE 383
IEEE 1202
Temperature Range
Operating . . . . . . . . -20ºC to + 70ºC
Storage . . . . . . . . . -40ºC to + 70ºC
Installation. . . . . . . . 0ºC to + 70ºC
• Heat, moisture, chemical resistant
fluoropolymer jacket (PVDF)
• Minimizes use of PVC consistent with
NRC Reg Guide 1.189 “Fire Protecton
for Operating Nuclear Power Plants”
• Suitable for plenum, riser, cable tray,
conduit, or general purpose spaces
• Meets ANSI-S-104-696 and Telcordia
GR-409 Weatherized Cable water
penetration resistance requirements.
• ANSI/ICEA S-83-596 (Premises)
• Telcordia GR-409 (Plenum: Horizontal
and Vertical Backbone)
Mechanical Data
NOMINAL
DIAMETER
PART NUMBER
CABLE TYPE
PVDF Jacketed,
Plenum Distribution Cable
PLENUM
RSKP002482#01
RSKP004482#01
RSKP006552#01
RSKP008602#01
RSKP012702#01
RSKP018782#01
RSKP024852#01
 Please specify fiber type when ordering (see below)
WEIGHT
TENSION
LBS (N)
FIBER
COUNT INCHES (MM) LBS/1000FT (KG/KM) INSTALLATION
2
0.19 (4.8)
18 (27)
150 (660)
4
0.19 (4.8)
18 (27)
150 (660)
6
0.22 (5.5)
22 (33)
150 (660)
8
0.24 (6.0)
26 (38)
150 (660)
12
0.26 (7.0)
34 (50)
150 (660)
18
0.28 (7.8)
40 (60)
300 (1335)
24
0.33 (8.5)
54 (80)
300 (1335)
LONG
TERM
45 (200)
45 (200)
45 (200)
45 (200)
45 (200)
90 (400)
90 (400)
BENDING RADIUS
INCHES (CM)
INSTALLATION LONG TERM
3.8 (9.6)
1.9 (4.8)
3.8 (96)
1.9 (4.8)
4.3 (11.0)
2.2 (5.5)
4.7 (12.0)
2.4 (6.0)
5.5 (14.0)
2.8 (7.0)
6.1 (15.6)
3.1 (7.8)
6.7 (17.0)
3.4 (8.5)
# - Specify outer jacket color when ordering:
2 = Orange outer jacket (standard for multimode)
8 = Black outer jacket
9 = Yellow outer jacket (standard for singlemode)
C = Aqua outer jacket (Standard for Laser-Link 300)
© 2011, AFL, all rights reserved. Revision 2, 6.13.13
Specifications are subject to change without notice.
www.R-SCC.com or (860) 653-8300
9
PVDF Jacketed Plenum Distribution Cable
Optical Performance Information
FIBER TYPE
Grade-index Multi-mode Fibers
(6) 62.5 Giga-Link 300
(8) 62.5 Giga-Link 1000
(5) 50 Giga-Link 600
(L) 50 Laser-Link 300 (OM3)
(1) 100/140 Graded Index MM Fiber
Step-index Singlemode Fibers
(9) Singlemode
(K) Futureguide SR-15e Bend Insensitive
(AL) Radiation Resistant Singlemode
MAXIMUM ATTENUATION
(dB/km)
1300
850 nm
nm
1310 nm 1550 nm
OVERFILLED LAUNCH
MINIMUM BANDWIDTH (MHz•km)
1 GIGABIT ETHERNET
MINIMUM LINK DISTANCE
(meters)
850 nm
1300 nm
850 nm
1300 nm
10GIGABIT ETHERNET
MINIMUM LINK DISTANCE (meters)
850 nm
1300 nm
(serial)
(serial)
3.5
3.5
3.5
3.5
5.0
1.2
1.2
1.2
1.2
4.0
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
200
350
500
1500*
100
600
600
500
500
100
300
500
600
900
N/A
550
1,000
600
550
N/A
32
65
82
300
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0.5
0.5
0.5
0.5
N/A
N/A
N/A
N/A
N/A
N/A
5,000
5,000
N/A
N/A
10,000
10,000
N/A
N/A
0.5
0.5
N/A
N/A
N/A
5,000
N/A
10,000
* 50/125 Laser-Link 300 Effective Modal Bandwidth = 2000 MHz/Km in 850nm window for 10 Gigabit Ethernet Links as measured by Differential Mode Delay (DMD).
• Gigabit Ethernet Link Distance are based on modal dispersion constraints. Actual link distance limits may also be constrained by attenuation, depending on customer’s specific loss budget.
• Available with specialty fibers (ex. 200/230, specialty coatings, radiation hardened options). Consult with our engineering specialists to select the best fiber for your application.
Maximum Cable Length - Reel Size
ITEM
Reel/Box Height (inches)
Reel/Box Outside Width (inches)
Drum Diameter (inches)
Reel Weight (lbs)
CAPACITY: METERS (FEET)
2 Fiber
4 Fiber
6 Fiber
8 Fiber
12 Fiber
18 Fiber
24 Fiber
FIBER BOX*
15.13
13.0
8.0
6.0
REEL A
16
15
8
10
REEL B
24
17
12
23
305 (1,000)
305 (1,000)
305 (1,000)
—
—
—
—
1,000 (3,281)
1,000 (3,281)
—
—
—
—
—
3,200 (10,500)
3,200 (10,500)
2,400 (7,874)
2,400 (7,874)
1,300 (4,265)
—
—
REEL C
30
15.25
12
34
5,000
5,000
4,000
4,000
2,100
(16,404)
(16,404)
(13,123)
(13,123)
( 6,890)
—
—
REEL D
34
21.25
12
44
REEL E
34
20
24
48
—
—
5,000 (16,404)
5,000 (16,404)
3,900 (12,795)
—
—
—
—
—
—
—
1,500 (4,921)
1,500 (4,921)
© 2011, AFL, all rights reserved. Revision 1, 7-6.11
Specifications are subject to change without notice.
www.R-SCC.com or (860) 653-8300
10
Deployable Cable
RSCC-AFL Deployable Cables are ideal for use in installations where extreme
environmental conditions are present. Designed to be deployed and retrieved
in the field, these cables are highly resistant to damage caused by repetitive
impact or harsh conditions.
Applications
• Field deployment in
abusive environments
• High traffic areas
• Security and sensing applications
• Video camera deployments for
ALARA purposes
Features
• Cut resistant, flame retardant
polyurethane outer jacket
• Highly flexible construction allows
for multiple deployments
• All aramid strength members
• Performance in wide temperature range
• High impact and crush resistance
• Durable in high traffic areas
• Water and UV resistant
• Multiple jacket colors available
• Harsh environments
• Temporary installation of critical
communications lines where quick
retrieval and re-use is necessary
Cable Components
Specifications
CHARACTERISTIC
Cyclic flexing
Crush resistance
Impact
Temperature cycling
Temperature Range
Operating - 46ºC to + 85ºC
TEST PROCEDURE
EIA/TIA-455-104
EIA/TIA-455-41
EIA/TIA-455-25
EIA/TIA-455-3
PERFORMANCE
2000
2000 N/cm
200
-46°C to 85°C
Installation - 20ºC to + 85ºC
Ordering Information
NOMINAL
DIAMETER
PART
NUMBER
XU00130180G
XU00258180G
XU00458180G
XU00661180G
XU01270180G
FIBER
COUNT
1
2
4
6
12
INCHES (MM)
.12 (2.9)
.23 (5.8)
.23 (5.8)
.24 (6.1)
.28 (7.0)
WEIGHT
LBS/1000FT (KG/
KM)
5.4 (8)
21.5 (32)
21.5 (32)
21.5 (33)
31.7 (47)
Note: Diameter and weight subject to change without notice
Special bandwidth and attenuation specification and/or
radiation resistant optical fibers are available. Consult with
our application specialists to select the correct fiber and
specifications for your application.
TENSION
LBS (N)
INSTALLATION
LONG TERM
250 (1112)
66 (290)
325 (1450)
66 (290)
325 (1450)
66 (290)
325 (1450)
66 (290)
394 (1750)
79 (350)
corresponding below.
5 = 50/125µm multimode GIGA-Link™ 600
6 = 62.5/125µm multimode GIGA-Link™ 300
* Other fiber types available.
BENDING
RADIUS
INCHES
(CM)
1.2 (3.0)
2.3 (5.8)
2.3 (5.8)
2.4 (6.1)
2.8 (7.0)
TEMPERATURE
RANGE
INSTALLAOPERATING
TION
STORAGE
-46°C to 85°C -20°C to 85°C -57°C to 85°C
9 = Single-mode
K = SM Futureguide SR-15e Bend Insensitive
© 2011, AFL, all rights reserved. Revision 0, 1.12.11
Specifications are subject to change without notice.
www.R-SCC.com or (860) 653-8300
11
Fiber Optic Cable Assemblies
Fiber Optic Cable Assemblies for the nuclear market utilize the most reliable brands of
each connector style on nuclear suitable, LSZH or plenum cables. Zipcord or ruggedized,
breakout style cables, can be selected for 2 fiber deployments, depending on the length
of the assembly and where it will be routed. For routing of more than 2 fibers between
locations, breakout style cables are typically specified to provide greater resistance to
impact and crush forces that could be imparted in open trays and ladder racks.
Use of pre-terminated assemblies eliminates labor-intensive field termination, yet
provides assurance of reliable performance since terminations are performed by trained
personnel using factory qualified processes and test procedures.
Applications
• Head-end termination
to a fiber “backbone”
• Termination of fiber rack systems
• Multi-floor deployment where select
fibers are used at each floor
• Terminations between equipment racks
• Cable trays
• General purpose industrial
• Nuclear power plants
• Splicing “qualified” pigtails
to “qualified” cables for safety
related applications
Features
• 2-24 fibers. Each fiber has its own jacket and aramid yarn reinforcement for rugged protection
• Flexible for ease of routing
• RoHS compliant - Riser, Plenum and LSZH rated cables available
• 1 meter standard breakout (other lengths are custom)
• Cable type tested to meet or exceed ANSI/ICEA S-83-596/GR-409-CORE
• Telcordia GR-326 and TIA 568-C3 compliant connector assemblies
•Breakout cables offer superior resistance to crush and impact forces
•Cable outer jacket and sub-unit jackets are PVC free
•Minimizes use of PVC consistent with US NRC Regulatory Guideline 1.189
“Fire Protection for Operating Nuclear Power Plants”
•Cables meet or exceed IEEE 383-1974 flame test requirements
Ordering Information
UST
Connector End A
Single-mode
ASC = Angle SC
AFC = Angle FC
USC = Ultra SC
UFC = Ultra FC
UST = Ultra ST
Multimode
PSC = SC MM
PFC = FC MM
PST = ST MM
UST
Connector End B
Single-mode
ASC = Angle SC
AFC = Angle FC
USC = Ultra SC
UFC = Ultra FC
UST = Ultra ST
XXX = No connector
ZB
024
Fiber Count
Cable Type
001 = 1
002 = 2
004 = 4
008 = 8
006 = 6
012 = 12
024 = 24
PB = Plenum Breakout
ZB = LSZH Breakout
PS = 3 mm Plenum Simplex
LA = 24 mm LSZH Simplex
PZ = 2 mm Plenum Zipcord
L24Z = 2.4 mm LSZH Zipcord
Multimode
PSC = SC MM
PFC = FC MM
PST = ST MM
XXX = No connector
Q
Fiber Type
Q=Single-mode
ITU-T G.652D
X=Single-mode
ITU-T G.657A BIF
2=Multimode
62.5/125 µm OM1
R=Multimode
50/125 µm OM2
L=Multimode
50/125 µm OM3/10G
0015
Cable Length (meters)
XXXX (specify length)
0010 = 10 meters
Telcordia is a registered trademark of Telcordia Technologies, Inc.
© 2013, AFL, all rights reserved. PP-1-00069. Revision 0, 10.8.13
Specifications are subject to change without notice.
12
Connector Specifications
PARAMETER
CONNECTOR
SC
Single-mode Assemblies
Image
Insertion loss (dB)
Maximum
Typical
Return Loss (dB)
Minimum
Temp Range (°C)
Durability Cycles
FC
ST
Ultra
Angle
Ultra
Angle
Ultra
Angle
0.25
0.2
0.25
0.2
0.25
0.2
0.25
0.2
0.4
0.2
—
—
-55 dB -65 dB
-40 to +85
500
Multimode Assemblies
Insertion loss (dB)
Maximum 0.5
—
Typical 0.25
—
Return Loss (dB)
Minimum -30 dB —
Temp Range (°C)
-40 to +85
Durability Cycles
500
Cable Options
Simplex/Duplex
900 µm
2.4 mm
3.0 mm
-55 dB -65 dB
-40 to +85
500
-50 dB —
-40 to +85
500
0.5
0.25
0.5
0.25
—
—
-30 dB —
-40 to +85
500
Simplex/Duplex
900 µm
2.4 mm
3.0 mm
—
—
-30 dB —
-40 to +85
500
Simplex/Duplex
900 µm
2.4 mm
3.0 mm
Telcordia is a registered trademark of Telcordia Technologies, Inc.
© 2013, AFL, all rights reserved. PP-1-00069. Revision 0, 10.8.13
Specifications are subject to change without notice.
13
FSM-60S Fusion Splicer Kit
The FSM-60S fusion splicer sets the standard for core alignment fusion splicing by
incorporating a user-friendly interface with enhanced features to provide the most
rugged and reliable fusion splicer in the market today. The new rugged construction
adds improved reliability by resisting shock, dust, and rain, and can withstand a
30" drop test.
The FSM-60S splices a fiber in 9 seconds and heats a 60mm splice sleeve in 30 seconds,
for a total cycle time of only 39 seconds. Automatic tube heater operation, automated
monitor image orientation, and battery charge capability during splicer operation
provide the end user a productivity tool they can count on.
FSM-60S
Software included provides the ability to download splice data to a PC for splice
data reporting, download splicer operating software via the internet to maintain peak
performance, and download video images from the splicer to enhance technical support.
Features
Detachable Work Table
•• Dual-axis core alignment provides the most controlled, most repeatable, lowest loss,
permanent connection for optical fibers.
•• Splice factory-terminated, singlemode APC pigtails or fusible connectors to fiber optic
cables to achieve lowest connection and return losses (recommended for analog video
transmission over fiber)
•• Imaging algorithms provide time-tested estimate of loss as part of splice process
•• Splicer design naturally applies equivalence of 23 kpsi proof test on 125µm clad fibers
after splice completion to help ensure long-term mechanical reliability.
•• Rugged construction providing shock, dust and moisture resistance
•• Dual monitor position with automatic image orientation
•• Automatic arc calibration and fiber identification
•• User-selectable fiber clamping method – sheath clamp or fiber holders
•• Auto-start tube heater feature
•• Color LCD display with anti-reflective coating for excellent visibility in bright sunlight
•• Simultaneous battery charge and splicer operation
•• Long life battery (up to 160 splice/heat cycles per charge)
•• Detachable work table incorporated into the transit case
•• Data and video download software and splicer upgrade software included;
software upgrades through PC application via the internet
•• Green friendly – RoHS & WEEE compliant
Ordering Information
DESCRIPTION
FSM-60S Fusion Splicer Kit (with cleaver, battery and cord)
Includes: BTR-08 Battery, DCC-14 Battery Charge Cord, CT30A Cleaver,
ADC-13 AC Adapter, ACC-14 AC Cord, Spare Electrodes (pair), S60A Sheath Clamp,
USB Cable, Splicer Carrying Strap, Quick Reference Guide, Video Instruction Manual,
JP-05 Splice Sleeve Cooling Tray, and Transit Case with Carrying Strap
AFL NO.
S014562
© 2008-2011, AFL, all rights reserved. Revision 3, 5.6.11
Specifications are subject to change without notice.
14
FSM-60S Fusion Splicer Kit
Specifications
PARAMETER
Model
Applicable Fibers
Cladding Diameter
Coating Diameter
Fiber Cleave Length
Typical Average Splice Loss
Splicing Time
Arc Calibration Method
Splicing Modes
Splice Loss Estimate
Storage of Splice Result
Fiber Display
Magnification
Viewing Method
Operating Condition
Mechanical Proof Test
Tube Heater
Tube Heating Time
Protection Sleeve Length
Splice/Heat Cycles with Battery
Power Supply
Terminals
Wind Protection
Dimensions
Weight
VALUE
FSM-60S Fusion Splicer
Single-mode (G.652 & G.657), Multimode (G.651), DS (G.653), NZDS (G.655)
80μm to150μm
100μm to 1,000μm
8 to 16mm with 250μm coating diameter, 16mm with 900μm coating diameter
0.02dB with SM, 0.01dB with MM, 0.04dB with DS, 0.04dB with NZDS, measured by cut-back method relevant to ITU-T and IEC standards
Typical 9 seconds with standard single-mode fiber
Automatic, real-time and by using results of previous splice when in AUTO mode, manual arc calibration function available
100 preset and user programmable modes
Based upon dual camera core alignment data
Last 2000 results to be stored in the internal memory
X or Y, or both X and Y simultaneously. Front or rear monitor display options with automated image orientation
300X for single X or Y view, or 187X for X and Y view
Dual cameras with 4.1 inch TFT color LCD monitor
0 to 5,000m above sea level, 0 to 95%RH and -10 to 50°C respectively
1.96 to 2.25N
Built-in tube heater with 30 heating modes; auto-start function
Typical 30 seconds with FP-03 sleeve, 35 seconds with FP3 (40), 35-55 seconds with Fujikura micro sleeves
60mm, 40mm, micro
Typical 160 cycles with power save functions activated
Auto voltage selection from 100 to 240V AC or 10 to 15V DC with ADC-11, 13.2V DC with BTR-08 battery
USB 1.1 (USB-B type) for PC communication. Mini-DIN (6-pin) for HJS-02/03 and SH-8 tube heater
Maximum wind velocity of 15m/s. (34 mph)
136W x 161D x 143H (mm) / 5.3W x 6.3D x 5.6H (inches)
2.3 kg (5.1 lbs) with AC adapter ADC-11; 2.7kg (5.9 lbs) with BTR-08 battery
CT-30 Series Fiber Cleaver
The 16-position blade yields 48,000 single-fiber cleaves before requiring replacement,
and the built-in scrap collector conveniently stores fiber shards until they can be safely
discarded. The CT-30 Cleaver is packaged with three scrap collection options that allow the
user to tailor it to their cleaving preferences.
Specifications
Included with Cleaver:
•• AD-30A Adapter Plate (CT30A only)
•• FC-02 Fiber Collector
•• FDB-02 Scrap Box (small)
•• FDB-03 Scrap Box (large)
•• SC-01 Side Cover (installed)
•• CC-21 Carrying Case
•• Hex Wrench (1.5mm)
•• Instruction Manual
PARAMETER
Applicable Fiber
Fiber Count
Coating Diameter
Cladding Diameter
Cleave angle capability
Blade lifetime
Dimensions (W x D x H)
Weight
VALUE
Conventional silica optical fiber
Single and up to 12 fiber ribbon
250um to 900um
125um
typically <0.5˚
48,000 fiber cleaves (4,000 12-fiber cleaves)
69mm x 82mm x 41mm (2.7" x 3.2" x 1.6")
180g (0.4 lbs)
Ordering Information
FIBER HANDLING
CLEAVE LENGTH AFL NO.
SYSTEM
Single Fibers:
AD-30A Adapter Plate 900µm: 10-20mm S014080
250-900µm coating, 125µm cladding
250µm: 6-20mm
DESCRIPTION APPLICATION
CT-30A
ACCESSORIES
Replacement Blade for CT-30 Series Cleavers
S012828
© 2008-2011, AFL, all rights reserved. Revision 3, 5.6.11
Specifications are subject to change without notice.
15
C860 QUAD OTDR and Certification Test Kit
Features
•• OTDR dynamic range: 22 dB (MM); 26 dB (SM)
•• Inspection capable with the DFS1 Digital FiberScope
•• Integrated OPM, OLS, and VFL (650 nm)
•• OLS sources: LED - 850/1300 nm; Laser - 1310/1550 nm
•• Full Auto, Expert, Real-Time OTDR test modes
•• >8 hours battery life or AC power
•• Touch and Test™ user interface; TRM® reporting software
•• Automatic Pass/Fail analysis (TIA/ISO/EN)
•• Internal (1000s tests) and USB storage
•• Wave ID detect if used with NOYES Wave ID series light sources
•• Available in Seven languages
Applications
•• Tier 1 and Tier 2 testing of premise networks
•• Bi-directionally measure loss and length of fiber links
•• Perform Pass/Fail Event and Link measurements using OTDR
•• Measure loss and length of fiber links
•• Certify SM and MM fibers using Pass/Fail criteria of industry
standards, applications and user-defined thresholds
•• Create professional certification reports
C860 with DFS1 Digital FiberScope
The NOYES C860 QUAD Certification and OTDR Test Kit from AFL includes one hand-held C840 QUAD OLTS Tester and one C850
QUAD OTDR/OLTS with built-in auto test functionality. With this kit, technicians can troubleshoot and perform both Tier 1 and Tier 2
certification tests of MM and SM fiber networks, store results and create professional test reports.
The C850 is both a QUAD Certification Tester and full-featured QUAD OTDR in a compact case with a large transflective touch screen
display suitable for both indoor and outdoor operation. The C850 features single-mode and multimode OTDR, Optical Light Sources
(OLS), Visual Fault Locator (VFL, 650 nm), and an Optical Power Meter (OPM). As an OTDR, the C850 supports Full Auto, Expert
(manual) and Real-Time test modes, simultaneous dual and single wavelength testing, and Event and Pass/Fail analysis based on
default or user-defined thresholds. The C840 QUAD Certification Tester includes VFL, OPM, and both single-mode (1310/1550 nm) and
multimode (850/1300 nm) OLS. The C840 may be used alone as a traditional power meter or light source to measure fiber loss or as a
visual fault locator to find fiber breaks.
The C860 kit combines ease of use (Touch and Test™) with multiple functionality and supports visual inspection per IEC 61300-3-35
using the DFS1 Digital FiberScope allowing users the ability to view and document connector end-face images with their OTDR traces
and loss results. Thousands of test results may be stored internally or on the supplied USB drive. Test results are transferable via a USB
cable or USB drive to a computer for viewing, printing, and analyzing with the supplied Windows® compatible software - TRM® (Test
Results Manager). Acceptance reports generated using TRM can include OTDR traces with summary and event information with or
without pass/fail indication, Event maps, and end-face images.
www.AFLglobal.com or 1-800-321-5298/1-603-528-7780
16
© 2008-2012, AFL, all rights reserved. C860-00-2000 Revision 1H, 2012-06-12
Specifications are subject to change without notice.
C860 QUAD OTDR and Certification Test Kit
Specifications
a
OTDR
Emitter Type
Safety Class
Center Wavelengths
Wavelength Tolerance
Dynamic Range (SNR = 1)
Event Dead Zone b
Attenuation Dead Zone c
Pulse Widths
Range Settings
Sampling Points
Minimum Data Point Spacing
Group Index of Refraction
(GIR)
Distance Uncertainty (m) d
Linearity e
MULTIMODE
SINGLE-MODE
POWER METER
Laser
Class I FDA 21 CFR 1040.10 and 1040.11,
IEC 60825-1: 2007-03
850/1300 nm
1310/1550 nm
±20/30 nm
±20/30 nm
22 dB
26 dB
1.5 m
9m
10, 30, 100, 300 ns; 1, 3, 10 µs
250 m to 64 km
250 m to 208 km
Calibrated Wavelengths
Detector Type
Measurement Range
Accuracy h
Measurement Units
Wavelength ID j
Set Reference
Data Storage
Tone Detection
Up to 16,000
0.25 m
1.4000 to 1.6000
GENERAL
C850 OTDR
Test Modes
±(1 + 0.005 % x distance + data point spacing)
Trace File Format
±0.05 dB/dB
Loss Threshold
0.05 dB
Length Measurement Range
Loss Resolution
0.01 dB
Data Storage
Reflectance Accuracy f
±2 dB
Wavelength
Output Power (nominal)
LIGHT SOURCE
Available Wavelengths (nom.)
Emitter Type
Safety Class
Output Power
Stability (after 15 minutes
warm up)
Wave ID Transmit
Tone Generation
C840 TESTER
OTDR (Full Auto, Expert,
Auto Test,
Real-Time), Auto Test,
OPM, OLS, VFL, DFS
OPM, OLS, VFL, DFS
SR-4731 (GR-196-CORE
N/A
Appendix A, B; SR-4731)
5 km (MM); 200 km (SM)
Internal flash memory
USB flash drive (2.0)
Downloadable from unit directly to PC
VISUAL FAULT LOCATOR
Emitter Type
Safety Class
850, 1300 1310, 1490, 1550, 1625 nm
InGaAs 2 mm
+6 to -60 dBm
±0.25
dB, dBm, mW
Yes (to -47 dBm)
Yes
Yes
Yes (to -47 dBm)
Data Storage Capacity
Laser
Class II FDA 21 CFR 1040.10 and 1040.11,
IEC 60825-1: 2007-03
650 ±20 nm
0.8 mW
USB
Tool Free Adapters
Modular cleanable SC/ST/LC
Size
Weight
Operating Temperature
Storage Temperature
Power
Battery Life k, m
MM PORT
SM PORT
850/1300 nm
1310/1550 nm
LED
Laser
Class I FDA 21 CFR 1040.10 and 1040.11,
IEC 60825-1: 2007-03
>-20 dBm, 62.5 µm MM g
0 dBm, 9 µm SM
±0.1 dB over 1 hour
±0.07 dB over 1 hour
±0.15 dB over 8 hours
Yes
270 Hz, 330 Hz, 1 KHz, 2 kHz
Recharge Time l, m
Display
Notes:
a. All specifications valid at 25 °C unless otherwise specified.
b. Typical distance between the two points 1.5 dB down each side of a reflective
spike caused by a -45 dB event using 10 ns pulse width.
c. Typical distance from event location to point where trace is within 0.5 dB of
backscatter caused by a -45 dB event using 10 ns pulse width.
d. Does not include GIR uncertainty.
e.Typical.
f. For a non-saturated event.
Internal >1000 fibers
Data Transfer to PC
27.4 x 19.3 x 7.1 cm
23 x 11 x 7 cm
(10.8 x 7.6 x 2.8 in)
(8.8 x 4.3 x 2.8 in)
2.3 kg ( 5 lb)
0.9 kg (2 lb)
-10 °C to +50 °C, 0 to 90 % RH (non-condensing)
-20 °C to +60 °C, 0 to 90 % RH (non-condensing)
Rechargeable Li-Ion or AC power adapter
>8 hours continuous testing
4 hours
16.51 cm (6.5 in),
color, transflective
9.65 cm (3.8 in),
color, transflective
g. Output power will be approximately 3 dB less if a 50 µm mandrel-wrapped
jumper is used instead of a 62.5 µm mandrel-wrapped jumper.
h. Accuracy measured at 25 ºC and -10 dBm per N.I.S.T. standards.
j. Automatic wavelength identification and switching when used with NOYES
Wave ID Series Light Sources.
k. Typical, depending on display brightness.
l. Typical, from fully discharged to fully charged state, unit may be operating.
m. External battery charger available.
www.AFLglobal.com or 1-800-321-5298/1-603-528-7780
17
© 2008-2012, AFL, all rights reserved. C860-00-2000 Revision 1H, 2012-06-12
Specifications are subject to change without notice.
C860 QUAD OTDR and Certification Test Kit
The C840 and C850 can be used together to perform Tier 1
dual wavelength MM (850/1300 nm) and SM (1310/1550 nm)
auto loss tests of one or two fibers in one or both directions as
well as measure both loss and length of the fibers and compare
to industry standards (TIA/ISO/EN), applications and userdefined thresholds values to certify the fibers. Either unit can be
identified as the Main or Remote.
The user may test two fibers at two wavelengths bi-directionally
and store the results into the main unit. Featuring rich file
naming, the Job setup wizard allows the user to define both the
cable and fiber end locations, creating easily identifiable trace
files, which are managed into Job and Cable folders.
The C850 OTDR and C840 Certification tester work with the
DFS1 Digital FiberScope.
Ordering Information
When placing an order, select options as follows: Model, Optical Configuration, Language, and Case.
Example: C860 — 100 — LP1 — H1
C860
NNN
LLL
CC
Case (CC)
H1 = Hard and soft case with SC-LC
cleaning accessories
Model
C860
Optical Configuration (NNN)
100 = QUAD 850/1300 nm MM and 1310/1550 nm SM
Language (LLL)
LP1 = Language: English, French, German,
Italian, Polish, Portuguese, Spanish
Specify Language when ordering a C860 Kit to indicate language preference of OTDR Quick Reference Guide.
Specify power cord type (country) when ordering a C860 Kit. One power cord is included with each AC adapter at no charge.
Additional power cords may be purchased separately.
www.AFLglobal.com or 1-800-321-5298/1-603-528-7780
18
© 2008-2012, AFL, all rights reserved. C860-00-2000 Revision 1H, 2012-06-12
Specifications are subject to change without notice.
C860 QUAD OTDR and Certification Test Kit
Ordering Information (continued)
Each kit includes one compact C850 QUAD OTDR/OLTS, one hand-held C840 QUAD Certification Tester, USB Flash drive, PC software
for OTDR trace analysis and certification or OPM loss reporting, (2) AC adapters, switchable test ports adapters, and accessories (see
below). The C860 hard carry case kit has room for up to 6 Fiber Rings, jumpers in a jumper carry case, and the DFS1 Digital FiberScope
kit (accessory items must be ordered separately).
CARRY CASE
ADAPTERS
CLEANING PRODUCTS
OTDR/OLS
OPM
VFI
SC, ST, LC
SC, 2.5, 1.25 mm
2.5, 1.25 mm
Soft (C850) and hard
cases
One-Click Cleaner SC/ST/FC, 2.5mm
One-Click Cleaner LC, 1.25 mm
Cletop - SB white tape
AFL NO.
C860-100-LP1-H1
Calibration Plans
AFL recommends annual calibrations on NOYES Test and Inspection products. Prepaid Cal plans offer two annual calibrations at a
discounted price, a convenient calibration expiration email service, express calibration services and access to the NOYES product
knowledge base. Cal Plus plans offer the same services as the Cal plans with the addition of a two year extended warranty (three years
total coverage).
MODEL
C860
2 YR CAL PLAN
2 YR CAL PLUS PLAN
AFL NO.
AFL NO.
CAL2-00-C860
CAL2-01-C860
C860—100—LP1—H1
OTDR, Inspection, and Cleaning Accessories
ITEM
DESCRIPTION
C850
QUAD OTDR/Auto Test Certification Tester
C840
QUAD Auto Test Certification Tester
Adapters
OTDR and OLS ports — SC, ST, LC
OPM ports — SC, 1.25 and 2.5 mm Universal
VFI ports — 1.25 and 2.5 mm Universal
Miscellaneous
Accessories
Mandrels (2) 62.5 µm, 3 mm jacket
and (2) 50 µm, 3 mm jacket
Stylus pens for touch screen. USB thumb drive, 1G.
USB to mini-USB cable
Small plastic parts box (2) to store adapter caps and mandrels
AC adapter (2), specify country of use
Cleaning
Accessories
Cases
(2) One-Click Cleaner SC/ST/FC, 2.5 mm; One-Click Cleaner LC/
MU, 1.25 mm (H2 kit only); Cletop SB white tape
Hard transit case — holds C850, C840, and above accessories
Soft case for C850
Report Software PC software and user guide
DESCRIPTION
DFS1 Digital FiberScope PC/UPC Inspection Kit
DFS1 Digital FiberScope APC Inspection Kit
DFS1 USB Digital Fiber Inspection Kit without Adapters
Fiber Ring, 1 fiber, 50/125 µm multimode, 150 m
Fiber Ring, 1 fiber, Laser Optimized, 50 µm multimode, 150 m
Fiber Ring, 1 fiber, 62.5/125 mm multimode, 150 m
AFL NO.
DFS1-00-04XU
DFS1-00-04XA
DFS1-00-04XN
FR1-M5-150-x1-x2 a
FR1-L5-150-x1-x2 a
FR1-M6-150-x1-x2 a
Fiber Ring, 1 fiber, single-mode, 150 m
Wet Cleaning Kit (shown) for SC/FC/ST/LC connectors.
Dry Cleaning Kit
One-Click Cleaner SC, ST, FC (500+ cleans)
One-Click Cleaner LC/MU (500+ cleans)
One-Click Mini-100 SC, ST, FC (100+ cleans)
One-Click Mini-100 LC/MU (100+ cleans)
One-Click Cleaner Ultra 2.5 SC, ST, FC (enlarged cleaning)
Zippered Jumper Carry Case
FR1-SM-150-y1-y2 a
8500-20-0900
8500-20-0901
8500-05-0001MZ
8500-05-0002MZ
8500-05-0005MZ
8500-05-0006MZ
8500-05-0007MZ
1400-01-0086PZ
Notes:
a. When ordering Fiber Rings, specify connector types (x1, x2, y1,y2).
FIBER SYSTEM
YES
S
NO
NOYES International Sales and Service Contact Information
9001
Available at www.AFLglobal.com/NOYES/Contacts
ISO
CERTIFIED
www.AFLglobal.com or 1-800-321-5298/1-603-528-7780
19
© 2008-2012, AFL, all rights reserved. C860-00-2000 Revision 1H, 2012-06-12
Specifications are subject to change without notice.
OFS 300 Optical Microscope
Inspect patch cords with NOYES OFS 300 from AFL. Designed for field use, with lab
quality optics, the OFS 300 scope delivers a high quality end-face image at 200x
magnification. Quickly identify scratches, dirt or other problems normally associated
with poor network performance.
FACT: A large percentage of network failures are caused by dirty or damaged end-faces
on fiber optic connectors. Inspecting jumper end-faces prior to connection is critical to
network performance. The OFS 300 scope provides a quality optical inspection tool at
an affordable price.
Safety: A built-in laser safety filter provides >40 dB IR protection to reduce risk of injury
to the eye if accidentally viewing an active fiber.*
Features
•• Laser safety filter installed
•• 200x image size
•• 2.5 mm Universal connector Included
•• Low battery LED indicator
•• Long battery life with 2 AA alkaline
•• Rugged, hand-held, easy-to-use
•• Tripod mount
Applications
•• Verify jumper ends are clean prior
to connecting to network
•• Inspect end-faces for scratches or pits
•• Eliminate the most common network
fault (bad connectors)
The OFS 300 features a universal adapter cap mount that accepts a variety of
NOYES thread-on style adapter caps (ordered separately) to ease inspection of many
connector style. A momentary power switch located on the top panel keeps one hand
free for focusing.
Tri-pod mount: For stationary work, the tri-pod mount allows the OFS 300 to attach
to any standard camera tri-pod.
The OFS 300 offers 60 hours of continuous battery life from standard 2 AA batteries
and features an LED indicator, which will flash when batteries require replacement.
*Always follow your company’s laser safety procedures and never use an optical
microscope to view live fiber optic connectors.
Specifications
a
OPTICAL SPECIFICATIONS
Nominal Magnification
Adapter Mount
Safety Filter
200X
Universal, thread-on
Schott KG3, >40 dB IR
GENERAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Power
Battery Life
Weight in Use
Size (H x W x D)
0°C to +50°C
-20°C to +50°C
2 AA batteries
>60 hours
0.67 kg (1.5 lb)
13 x 5 x 20 cm (5 x 2 x 8 in)
Note: a. All specifications valid at 25°C unless otherwise specified.
Ordering Information
INCLUDES
AFL NO.
OFS 300 Inspection Scope, 2 AA batteries, neck strap, 2.5 mm universal
adapter cap, and user’s guide
OFS 300
NOYES International Sales and Service Contact Information
Available at www.AFLglobal.com/NOYES/Contacts
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
20
© 2002-2011, AFL, all rights reserved. OFS1-00-2000 Revision U, 2011-07-27
Specifications are subject to change without notice.
DFS1 Digital FiberScope
The DFS1 Digital FiberScope supports magnified video inspection
of optical fiber connector end-faces during fiber optic cable
and connector installation and maintenance. The ergonomically
designed hand-held unit illuminates fiber end-faces and delivers
magnified images via USB port to AFL’s M-series OTDRs
(M210, M200, M700) or C-series OTDRs and Certification Testers
(C840, C850, C860, C880). FiberScope software displays, labels
and stores captured images as part of connector installation
and/or maintenance records.
DFS1 Digital FiberScope
A large adjustment knob permits easy focusing using real-time
view. Once focused, a conveniently located trigger button signals
the attached display device to capture the image for analysis and
archiving. The scope’s ergonomic shape and control locations
support comfortable, single-handed operation.
Clean connector
The DFS1 is powered through the USB port, eliminating the need
for an additional battery or AC power supplies. Electronic video
inspection eliminates all danger of eye damage from active (lit)
fibers carrying either visible or infrared wavelengths.
An extensive assortment of adapters supports inspection of
a wide range of optical jumper cable connector ferrules and
bulkhead adapters. Bulkhead adapter tips are available in
multiple lengths as well as 60° angle. Connector adapters are
available for PC, UPC or APC polished ferrules in 1.25 mm,
2.5 mm and other diameters. The DFS1 is available in three
different kits which provide either PC/UPC adapters, APC
adapters or no adapters.
Dirty connector
DFS1 Digital FiberScope with M210 OTDR
Features
•• Ergonomic, hand-held design
•• Single-handed operation
•• 400x magnification
•• Fast, easy focus and display capture
•• Video output via USB port to M210, M200, M700, C840, C850,
C860, C880 or user PC
•• Powered from USB; no batteries required
•• Extensive assortment of interchangeable fiber connector
and bulkhead adapter tips
•• Adapter tips easily changed; no tools required
•• Use AFL SimpleView PC software with DFS1 to inspect
connectors using a laptop PC
AFL SimpleView™ Fiber Inspection Software is an application,
which permits the DFS1 Digital FiberScope to be used with
Windows® XP or Windows® 7 computers. AFL SimpleView
software displays a live, high-resolution video image of the endface of an optical fiber on the PC’s display. SimpleView software
is a free download www.AFLglobal.com.
Applications
•• Ideal for telco, broadband and enterprise applications
•• Optical connector and bulkhead adapter inspection
•• Display and analyze fiber end-face quality on C- and M-series
•• Visually inspect fiber end-faces for damage
or contamination impairing optical transmission
•• Generate installation inspection records, associating captured
digital photo with fiber ID
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
21
© 2011-2012, AFL, all rights reserved. DFS1-00-2000 Revision 1C, 2012-01-30
Specifications are subject to change without notice.
DFS1 Digital FiberScope
Specifications
DFS1 Digital FiberScope with M700 OTDR
a
PARAMETERS
VALUE
400X
Magnification
~400 µm x 300 µm
Field of View
0.5 μm detectable
Resolution
0°C to 50°C
Operating Temperature
-20°C to 70°C
Storage Temperature
Manual adjustment, 2 mm max travel
Focus
35 mm diameter x 175 mm length (without tip)
200 g
Dimensions
Weight
Blue LED
USB port of M-series OTDRs or C-series OTDRS and Certification Testers
Light Source
Power Supply
Note:
a. All specifications valid at 23°C ±2°C (73.4°F ±3.6°F) unless otherwise specified.
Ordering Information
DFS1 Digital FiberScope Kit
The DFS1 is available in three different kits which provide either PC/UPC adapters, APC
adapters, or no adapters. All kits include soft carry case, a storage box to hold up to six
adapter tips, FiberScope display software update for M-series OTDRs (M200, M700)
or C-series OTDRs and Certification Testers (C840, C850, C860, C880), and a quick
reference guide.
DESCRIPTION
DFS1 Digital FiberScope PC/UPC Inspection Kit includes:
(1) DFS1-00-04X0MR DFS1 USB Digital FiberScope
(1) DFS1-00-0001MR Universal 1.25 mm male PC adapter tip
(1) DFS1-00-0002MR Universal 2.5 mm male PC adapter tip
(1) DFS1-00-0003MR SC and FC female bulkhead adapter tip
(1) DFS1-00-0004MR LC female bulkhead adapter tip
(1) DFS1-04-0001MZ soft carry case for scope and adapters
(1) 8500-05-0001MZ One-Click Cleaner SC, ST, FC
(1) 8500-05-0002MZ One-Click Cleaner LC/MU
(1) 1400-01-0093MZ 6-compartment adapter tip storage box
(1) Digital FiberScope display software update for M200, M700, C840, C850, C860, or C880
DFS1 Digital FiberScope APC Inspection Kit includes:
(1) DFS1-00-04X0MR DFS1 USB Digital FiberScope
(1) DFS1-01-0002MR Universal 2.5 mm male APC adapter tip
(1) DFS1-01-0003MR SC/APC and FC/APC bulkhead adapter tip
(1) DFS1-01-0011MR SC/APC bulkhead adapter tip
(1) DFS1-04-0001MZ soft carry case for scope and adapters
(1) 8500-05-0001MZ One-Click Cleaner SC, ST, FC
(1) 1400-01-0093MZ 6-compartment adapter tip storage box
(1) Digital FiberScope display software update for M200, M700, C840, C850, C860, or C880
DFS1 USB Digital Fiber Inspection Kit without Adapters includes:
(1) DFS1-00-004X0MR DFS1 USB Digital FiberScope
(1) Soft carry case for scope and adapters
(1) 6-compartment adapter tip box
(1) Digital FiberScope display software update for M200, M700, C840, C850, C860, or C880
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
22
AFL NO.
DFS1-00-04XU
DFS1-00-04XA
DFS1-00-04XN
© 2011-2012, AFL, all rights reserved. DFS1-00-2000 Revision 1C, 2012-01-30
Specifications are subject to change without notice.
DFS1 Digital FiberScope
Ordering Information (continued)
DFS1 Accessories
DFS1-00-0001MR
DESCRIPTION
Soft carry case for DFS1 Digital FiberScope and adapters
AFL NO.
DFS1-04-0001MZ
6-compartment adapter tip storage box
1400-01-0093MZ
11-compartment adapter tip storage box
1400-01-0094MZ
One-Click Cleaner SC, ST, FC
8500-05-0001MZ
One-Click Cleaner LC/MU
8500-05-0002MZ
AFL SimpleView PC viewer software
Free download from
www.AFLglobal.com
DFS1 Adapter Tips
DFS1-00-0002MR
DFS1-00-0004MR
DFS1-00-0013MR
The following table identifies commonly required adapter tips. Other adapter tips
available. Please consult the factory for additional adapter tips and prices.
DESCRIPTION
PC FERRULE CONNECTOR ADAPTER TIPS
AFL NO.
Universal 1.25 mm tip for PC ferrule connector
Universal 2.5 mm tip for PC ferrule connector
Universal 2.0 mm tip for PC ferrule connector
Slim 1.6 mm tip for PC ferrule (termini)
Slim 1.25 mm probe tip for LuxCis and termini
Slim 2.5 mm PC ferrule tip for ELIO and termini
Tip for ELIO 1.25 mm ferrule connector
SC/PC AND FC/PC BULKHEAD ADAPTER TIPS
DFS1-00-0001MR
DFS1-00-0002MR
DFS1-00-0005MR
DFS1-00-0006MR
DFS1-00-0038MR
DFS1-00-0039MR
DFS1-00-0008MR
Tip for SC/PC and FC/PC bulkhead adapter
Short extended tip for SC/PC and FC/PC bulkhead adapter
Medium extended tip for SC/PC and FC/PC bulkhead adapter
Long extended tip for SC/PC and FC/PC bulkhead adapter
60° angled tip for SC/PC and FC/PC bulkhead adapter
60º angled tip for SC/PC bulkhead adapter
ST/PC BULKHEAD ADAPTER TIPS
DFS1-00-0003MR
DFS1-00-0010MR
DFS1-00-0011MR
DFS1-00-0012MR
DFS1-00-0013MR
DFS1-00-0040MR
Tip for ST/PC bulkhead adapter
Short extended tip for ST/PC bulkhead adapter
Medium extended tip for ST/PC bulkhead adapter
Long extended tip for ST/PC bulkhead adapter
60° angled tip for ST/PC bulkhead adapter
LC/PC BULKHEAD ADAPTER TIPS
DFS1-00-0014MR
DFS1-00-0015MR
DFS1-00-0016MR
DFS1-00-0017MR
DFS1-00-0018MR
Tip for LC/PC bulkhead adapter
Short extended tip for LC/PC bulkhead adapter
Medium extended tip for LC/PC bulkhead adapter
Long extended tip for LC/PC bulkhead adapter
60° angled tip for LC/PC bulkhead adapter
DFS1-00-0004MR
DFS1-00-0019MR
DFS1-00-0020MR
DFS1-00-0021MR
DFS1-00-0022MR
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
23
© 2011-2012, AFL, all rights reserved. DFS1-00-2000 Revision 1C, 2012-01-30
Specifications are subject to change without notice.
DFS1 Digital FiberScope
Ordering Information (continued)
DESCRIPTION
E2000/PC BULKHEAD ADAPTER TIPS
AFL NO.
Short extended tip for E2000/PC bulkhead adapter
Medium extended tip for E2000/PC bulkhead adapter
Long extended tip for E2000/PC bulkhead adapter
MU/PC BULKHEAD ADAPTER TIPS
DFS1-00-0023MR
DFS1-00-0024MR
DFS1-00-0025MR
Tip for MU/PC bulkhead adapter
Short extended tip for MU/PC bulkhead adapter
Medium extended tip for MU/PC bulkhead adapter
Long extended tip for MU/PC bulkhead adapter
60° angled tip for MU/PC bulkhead adapter
MTP/PC MULTI-FIBER ADAPTER TIPS (FERRULE & BULKHEAD)
DFS1-00-0026MR
DFS1-00-0027MR
DFS1-00-0028MR
DFS1-00-0029MR
DFS1-00-0030MR
MTP/PC bulkhead adapter extended tip; includes base plus MTP/PC front end tip.
Test ferrules using adapter tip with bulkhead adapter.
Front end tip for MTP/PC ferrule and bulkhead adapter
MTP/PC and MTP/APC bulkhead adapter extended tip kit; includes base plus MTP/PC
and MTP/APC front end tips. Test ferrules using adapter tip with bulkhead adapter.
MISCELLANEOUS PC BULKHEAD ADAPTER TIPS
DFS1-00-0037MR
Tip for LEMO 2.0 mm bulkhead adapter
Tip for LX.5/PC bulkhead adapter
Tip for 2.0 mm termini bulkhead adapter
Tip for 1.6 mm termini bulkhead adapter
Tip for ELIO 1.25 mm bulkhead adapter
APC TIPS
DFS1-00-0031MR
DFS1-00-0032MR
DFS1-00-0033MR
DFS1-00-0034MR
DFS1-00-0036MR
Universal 1.25 mm tip for APC ferrule connector
Universal 2.5 mm tip for APC ferrule connector
Tip for SC/APC and FC/APC bulkhead adapter
Tip for SC/APC bulkhead adapter
Tip for LC/APC bulkhead adapter
DFS1-01-0001MR
DFS1-01-0002MR
DFS1-01-0003MR
DFS1-01-0011MR
DFS1-01-0004MR
Short extended tip for SC/APC bulkhead adapter
60° angled tip for SC/APC bulkhead adapter
Tip for E2000/APC bulkhead adapter
Tip for LX.5/APC bulkhead adapter
MTP/APC bulkhead adapter extended tip kit; includes base plus MTP/APC front end tip.
Test ferrules using adapter tip with bulkhead adapter.
Front end tip for MTP/APC ferrule and bulkhead adapter
DFS1-01-0005MR
DFS1-01-0006MR
DFS1-01-0008MR
DFS1-01-0009MR
DFS1-01-0010MR
DFS1-00-0041MR
DFS1-00-0042MR
DFS1-01-0012MR
NOYES International Sales and Service Contact Information
Available at www.AFLglobal.com/NOYES/Contacts
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
24
© 2011-2012, AFL, all rights reserved. DFS1-00-2000 Revision 1C, 2012-01-30
Specifications are subject to change without notice.
VFI2 and HiLite Visual Fault Identifiers
The NOYES VFI2 and HiLite visible red laser sources from AFL are designed to
troubleshoot faults on fiber optic cables. Light generated by these units will escape from
sharp bends and breaks in jacketed or bare fibers, as well as poorly-mated connectors.
They can quickly identify faults in fiber optic jumper cables, distribution frames, patch
panels, and splice trays.
The HiLite and VFI2 are an excellent complement to an OTDR because they can locate
faults inside the OTDR’s dead-zone. Other applications include end-to-end continuity
checks, identifying connectors in patch panels and fibers during splicing operations.
VFI2 Visual Fault Identifier
Trace cables in messy or undocumented setups. A VFI unit provides a quick means
of finding the “other end” from amongst cluttered cables. Simply connect the VFI
to one end and look for the visual red light transmitted out the opposite connector.
Fiber Coupled Lasers for Best Test Results: NOYES VFI2 units deliver 1 mW of output
power into 9/125 single-mode fiber to ensure long range and exceptional brightness
for locating defects in single-mode and multimode fibers.
The VFI2 and HiLite units use a threaded connector adapter interface to support adapter
removal for connector cleaning and field changing of adapter styles. The 2.5 mm adapter
accepts PC and angled connectors FC, SC, ST, etc. and the 1.25 mm adapter accepts LC
and MU connectors.
A Visible Fault Indicator (VFI) is an essential tool for fiber technicians.
VFI2 Visual Fault Identifier
Features
•• Visible red laser source, 650 nm
•• High power, 1 mW into 9/125
single-mode fiber
•• Compact size
•• Universal connector interface for
quick connection
•• 2.5 mm Universal adapter included
•• 1.25 mm Universal adapter available
Applications
•• Identify fiber faults inside OTDR deadzone
•• Identify sharp bends or breaks in fibers
•• Identify poorly mated connectors
•• Verify AFL FAST Connector Installation
Ordering Information
VFI2 Models
DESCRIPTION
VFI2 visual fault identifier with 2.5 mm adapter
AFL NO.
VFI2-00-0900PR
VFI2 visual fault identifier with 2.5 mm and 1.25 mm adapters
VFI2-01-0900PR
HiLite Models
DESCRIPTION
AFL NO.
HiLite visual fault identifier with 2.5 mm adapter
VFI3-00-0900PR
HiLite visual fault identifier with 2.5 mm and 1.25 mm adapters
VFI3-01-0900PR
Adapters
DESCRIPTION
2.5 mm Universal adapter b with captivated sleeve
AFL NO.
2900-50-0007MR
1.25 mm Universal adapter c with captivated sleeve
2900-50-0010MR
Notes:
a. All specifications valid at 25°C unless otherwise specified.
b. 2.5 mm Universal adapter accepts SC, FC, ST, E2000 ferrules.
c. 1.25 mm Universal adapter accepts LC, MU ferrules.
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
25
© 2002-2012, AFL, all rights reserved. VFI3-00-2000 Revision N, 2012-01-27
Specifications are subject to change without notice.
SMLP5-5 Test Kit
The SMLP5-5 Test Kit with Wave ID, Set Reference, and Data
Storage combines the OPM5-2D optical power meter and
OLS4 integrated LED and laser light source and is ideally suited
for testing fiber optic networks with hybrid (single-mode and
multimode) cables.
The OLS4 features 850/1300 nm LED output from a multimode
output port and 1310/1550 nm laser output from a single-mode
output port. Each wavelength may be transmitted individually
at CW or with user selectable modulated Tone(SM output). Also,
each wavelength may be transmitted with Wave ID. Both output
ports are equipped with UCI based removable adapters to allow
the output connectors to be inspected and cleaned.
The OPM5-2D is a full-featured, hand-held optical power
meter designed for measuring optical power in premise, telco,
or broadband networks and for performing insertion loss
measurements on multimode or single-mode fiber optic links.
The standard Wave ID feature (when used with NOYES OLS series
light sources) automatically detects and sets the wavelength(s),
preventing setup and measurement errors. It significantly
increases efficiency and reduces technician errors—and saves
testing time—by eliminating the need to test each wavelength
individually. The OPM5-2D stores optical references for each
calibrated wavelength and offers multiple test tone detection
for fiber identification.
Features (SMLP5-5 Test Kit)
•• Wave ID reduces test time
•• Hand-held, rugged, lightweight
•• Cost-effective, easy-to-use
•• N.I.S.T traceable
•• OLS4 Quad Light Source
•• Dual or single Wave ID, CW, Tone
•• Industry standard 2 kHz test Tone
•• 50 µm and 62.5 µm mandrels
•• OPM5-2D Optical Power Meter
•• File management system organizes stored test data
•• Storage capability >500 fibers
•• USB port for download of stored data
•• TRM™ PC Reporting Tool (Windows® compatible)
•• Apply certification rules to test results
•• Create professional test reports
•• Archive test results
Data Storage of Test Results
The OPM5-2D File Management system allows technicians
to organize test results into multiple files and transfer stored
results via USB to a PC for analyzing, generating reports, and
printing. The supplied powerful PC Analysis and Reporting Tool
(TRM® - Test Results Management software) allows users to
apply industry standards based rules to test results and create
comprehensive certification reports. Users can generate network
Pass/Fail results demonstrating compliance to industry standards
and illustrate headroom. TRM is a Windows® compatible
software. The SMLP5-5 test kit is fully N.I.S.T. traceable.
Applications
•• Certify multimode and single-mode links per TIA/EIA standards
•• Fiber identification prior to splicing
•• Passive Optical Networks (PON) testing
•• Save test data for report generation with NOYES TRM Software
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
26
© 2002-2012, AFL, all rights reserved. SMLP-55-2001 Revision F, 2012-07-11
Specifications are subject to change without notice.
SMLP5-5 Test Kit
OLS4 Light Source Specifications
OPTICAL
Wavelength
Emitter Type
Spectral Width
Output Power
Output Stability
GENERAL
Power
Battery Life
Available Adapters
Operating Temperature
Storage Temperature
Size (H x W x D)
Weight
MM OPTICAL PORT
OPM5-2D Specifications
a
SM OPTICAL PORT
850
1300
1310
1550
±30 nm
-10/+50 nm ±20 nm
±20 nm
LED
Laser
Class I FDA 21 CFR 1040.10 and 1040.11,
IEC 60825-1: 2007-03
40 nm (typ) 120 nm (typ) 5 nm (max) 5 nm (max)
>-20 dBm,
0 dBm,
62.5 µm multimode b
9 µm single-mode
±0.1 dB over 8 hours
±0.05 dB over 1 hour
(after 5-minute warm-up) (after 15-minute warm-up)
±0.1 dB over 8 hours
(after 15-minute warm-up)
OPTICAL
OPM5-2D
Calibrated Wavelengths
850, 1300, 1310, 1490, 1550 nm
Detector Type
Germanium (Ge)
Measurement Range
+6 to -60 dBm
Tone Detect Range
+6 to -50 dBm
+6 to -45 dBm for 850 nm
+6 to -50 dBm
+6 to -45 dBm for 850 nm
±0.25 dB
0.01 dB
dB, dBm, μW
Wavelength ID Range
Accuracy c
Resolution
Measurement Units
GENERAL
Power
Battery Life
Operating Temperature
Storage Temperature
Size (H x W x D)
Weight
2 AA batteries, optional AC adapter
Typical 30 hours,
Typical 72 hours,
minimum 20 hours
minimum 40 hours
SC FC, ST, LC
-10°C to 50°C, 90 % RH (non-condensing)
-30°C to 60°C, 90 % RH (non-condensing)
14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in)
0.29 kg (0.65 lb)
a
2 AA batteries, optional AC adapter
300 hours
-10°C to 50°C, 90 % RH (non-condensing)
-30°C to 60°C, 90 % RH (non-condensing)
14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in)
0.26 kg (0.58 lb)
Notes:
a. All specifications valid at 25°C unless otherwise specified.
b. Output power will be approximately 3 dB less if a 50 µm mandrel-wrapped jumper is used instead of a 62.5 µm mandrel-wrapped jumper.
c. Accuracy measured at 25ºC and -10 dBm per N.I.S.T. standards.
Ordering Information
Test jumpers and connector adapters are required for operation (purchased separately). Test jumpers with a variety of connector styles
and fiber types and adapter caps for most common connectors may be purchased from AFL.
INCLUDES
OLS4 optical light source, OPM5-2D optical power meter, AA batteries, protective rubber boots, adapter cap, USB cable,
PC reporting tool - TRM® (Windows® compatible), 50 and 62.5 µm mandrels, and carry case
AFL NO.
SMLP5-5
Calibration Plans
AFL recommends annual calibrations on NOYES Test and Inspection products. Prepaid Cal plans offer two annual calibrations at a
discounted price, a convenient calibration expiration email service, express calibration services and access to the NOYES product
knowledge base. Cal Plus plans offer the same services as the Cal plans with the addition of a two year extended warranty (three years
total coverage).
MODEL
SMLP5-5
2 YR CAL PLAN
2 YR CAL PLUS PLAN
AFL NO.
AFL NO.
CAL2-00-SMLP5-5
CAL2-01-SMLP5-5
NOYES International Sales and Service Contact Information
Available at www.AFLglobal.com/NOYES/Contacts
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
27
© 2002-2012, AFL, all rights reserved. SMLP-55-2001 Revision F, 2012-07-11
Specifications are subject to change without notice.
M210 Multifunction Micro OTDR
Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks
Features
•• 30 dB dynamic range single-mode
•• 16-hour battery life
•• Remote display capable
•• Touch and Test™ intuitive user interface
•• New faster processor
•• Crisp bright display for indoor/outdoor viewing
•• Integrated OPM standard; integrated VFL standard
•• Inspection capable with DFS1 Digital FiberScope
•• Rugged, hand-held, lightweight (<1 kg)
•• Prepaid Calibration plans, Cal and Cal Plus (see next page)
Test Modes
•• Full Auto OTDR – Normal (point-to-point) fiber cable construction
M210 OTDR with DFS1 Digital FiberScope
testing and fault location
•• Expert OTDR – Full function OTDR for experienced users includes
Auto and Auto-Once setup
•• Real-Time OTDR – Fault location, splice verification
•• Optical Power Meter – Measure optical power or fiber loss
•• Visual Fault Locator – Red laser for fiber bend and break location
Languages supported
•• English
•• French
•• German
•• Italian
•• Spanish
•• Polish
•• Portuguese
The NOYES M210 is the only inspection ready QUAD OTDR that combines OTDR, OPM and VFL capability with a proven, easy-to-use
and easy-to-learn user interface. The M210 is the latest addition to the M200 family of OTDRs. Like other members of the M200 family,
the M210 offers the intuitive Touch and Test user interface in a rugged, lightweight, easy-to-hold package ready for field use. The M210
features a more powerful processing engine, a higher resolution display and, for the first time in an OTDR of its size, an integrated
Optical Power Meter.
Touch and Test simplifies the M210 user experience, minimizes human errors and reduces training time by providing one-touch access
to the Full-Auto, Expert and Real-Time OTDR test modes, OPM measurement mode as well as the Results Management and Job
Creation menus. The M210 allows setting Pass/Fail thresholds to industry standard TIA/ISO or user-values and will automatically alert
users of failing fibers. Touch and Test enables both experts and novices alike to complete jobs more accurately and in less time.
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
28
© 2012, AFL, all rights reserved. M210-00-2000 Revision 1B, 2012-06-18
Specifications are subject to change without notice.
M210 Multifunction Micro OTDR
M210 Models and Included Adapters
WAVELENGTHS (nm)
850
1300
1310
OPM PORT
ADAPTERS
AFL BASE
MODEL NO.
SC, FC
SC, 2.5 mm Universal
M210-20
26/26
SC, ST
SC, 2.5 mm Universal
M210-22
26/26/30/30
SC, FC, ST
SC, 2.5 mm Universal
M210-25
DYNAMIC OTDR PORT
RANGE (dB) ADAPTERS
1550
30/30
All M210 OTDRs include a USB flash
drive, an AC adapter, UCI switchable
adapters for OTDR and OPM ports, trace
analysis and documentation software and
a quick reference guide.
Ordering Information
DESCRIPTION
M210 QUAD Certification Kit (Tier 1 and 2): M210 QUAD, OLS4, DFS1* in hard case
M210 QUAD Test and Inspection Kit (Tier 2): M210 QUAD, DFS1* in hard case
AFL NO.
M210-25K-01-HC2
M210-25K-01-HC1
* When ordering, specify DFS1 model. The DFS1 FiberScope kit is available as either PC/UPC inspection kit
(DFS1-00-04XU model) or APC inspection kit (DFS1-004XA model).
M210 OTDR, SM (1310/1550), OPM, VFL in hard case
M210 OTDR, MM (850/1300) OPM, VFL in hard case
M210-20U-01-HC
M210-22U-01-HC
M210 OTDR, QUAD (850/1300/1310/1550), OPM, VFL in hard case
M210 OTDR, SM (1310/1550) OPM, VFL in soft case
M210 OTDR, MM (850/1300) OPM, VFL in soft case
M210 OTDR, QUAD (850/1300/1310/1550), OPM, VFL in soft case
M210-25U-01-HC
M210-20U-01
M210-22U-01
M210-25U-01
M210
NN
U
LL
When ordering, select options as follows:
Optical Configuration (NN), (U) for UPC
connection and Language (LL). Add (HC)
only if ordering the hard case option.
Example: M210-25U-01-HC -> This
model number indicates M210 QUAD
with the English/European language pack
in the optional hard case.
HC
Hard Case option (HC)
Optical Configuration (NN)
20 = 1310/1550 nm SM
22 = 850/1300 nm MM
25 = 850/1300 nm MM and 1310/1550 nm SM
(Select (HC) only if ordering hard case option)
Language (LL)
01 = English, French, German, Italian,
Polish, Portuguese, Spanish
OTDR port ferrule (U = UPC)
*Specify Language for OTDR Quick Reference Guide
Calibration Plans
M210 OTDR AND/OR KIT
MODEL
M210-25K-01-HC1
M210-25K-01-HC2
M210-20U-01-HC
M210-22U-01-HC
M210-25U-01-HC
M210-20U-01
M210-22U-01
M210-25U-01
2 YR CAL PLAN
AFL NO.
CAL2-00-M210-25K-HC1
CAL2-00-M210-25K-HC2
CAL2-00-M210-20
CAL2-00-M210-22
CAL2-00-M210-25
CAL2-00-M210-20
CAL2-00-M210-22
CAL2-00-M210-25
2 YR CAL PLUS PLAN
AFL NO.
CAL2-01-M210-25K-HC1
CAL2-01-M210-25K-HC2
CAL2-01-M210-20
CAL2-01-M210-22
CAL2-01-M210-25
CAL2-01-M210-20
CAL2-01-M210-22
CAL2-01-M210-25
AFL recommends annual calibrations
on NOYES Test and Inspection products.
Prepaid Cal plans offer two annual
calibrations at a discounted price, a
convenient calibration expiration email
service, express calibration services and
access to the NOYES product knowledge
base. Cal Plus plans offer the same
services as the Cal plans with the
addition of a two year extended warranty
(three years total coverage).
NOYES International Sales and Service Contact Information
Available at www.AFLglobal.com/NOYES/Contacts
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
29
© 2012, AFL, all rights reserved. M210-00-2000 Revision 1B, 2012-06-18
Specifications are subject to change without notice.
One-Click Cleaner Series
With Innovative Push-to-Clean Design
The One-Click Cleaner is an easy-to-use option for cleaning connectors on jumpers
and in adapters. Simply insert the One-Click Cleaner into an adapter and push until
an audible “click” is heard. The One-Click Cleaner uses the mechanical push action to
advance an optical grade cleaning tape while the cleaning tip is rotated to ensure the
fiber end-face is effectively, but gently cleaned. The One-Click Cleaner is a must-have for
field technicians. Small enough to fit in a shirt pocket and a great addition to cleaning
kits. Save your wrist – no more twist!
MU/LC
Mini-100
SC/ST/FC
ODC
Mini-500
Compact One-Click Cleaner Mini: Offering the same technology and
performance as the original, the One-Click Cleaner is now available in a smaller, more
compact size, which allows for cleaning of connectors in tighter places. Its smaller size
also makes it a great addition to test kits and cleaning kits. The One-Click Mini that is
offered by AFL as a low cost solution with 100+ cleans per unit is now also available
with same 500+ cleans per unit as the standard One-Click. The One-Click Mini is an
effective, easy-to-use cleaning solution for SC, ST, FC, LC, MU and TFOCA connectors.
Rugged ODC® Version: With the increasing demand of Outdoor Connector
(ODC) plug and socket styles, the ODC One-Click Cleaner, which cleans the ferrules in
ODC plug, socket and 1.25 mm ferrules, is an essential cleaning tool for WiMax Base
Station, Fiber-to-the-Antenna, Broadcasting and Surveillance Video technicians.
One-Click Ultra Cleaner 2.5: The new One-Click Ultra Cleaner 2.5 has an
enlarged cleaning area to clean more of the connector end-face. The One-Click Ultra
Cleaner 2.5 cleans up to a 2 mm diameter area of the connector end-face. The One-Click
Ultra Cleaner is a superior cleaner for SC, ST, and FC connectors.
One-Click Cleaner D-LC (Duplex LC): Reduce cleaning time
with the new One-Click Cleaner D-LC. Offering the same performance and easy-to-use
one-click technology as the original, the One-Click Cleaner D-LC cuts cleaning time in
half by effectively cleaning both LC connectors of a duplex LC at one time. 500+ duplex
LC cleans per cleaner (1000+ LC connector cleans).
Features
D-LC
2.5 Ultra
•• Cleans connectors on jumpers and in adapters; low cost per clean
•• Effective on a variety of contaminates including dust and oils
•• Ergonomic, comfortable design with single action cleaning
•• Automatic advance ensures each clean is performed with fresh cleaning tape
•• Compliant with EU/95/2002/EC Directive (RoHS)
•• Available with enlarged cleaning area up to 2 mm
•• Duplex LC version available
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
30
© 2008-2012, AFL, all rights reserved. 8500-05-2000 Revision 1F, 2.16.12
Specifications are subject to change without notice.
One-Click Cleaner Series
Illustration of cleaning procedure for SC connectors
SC Adapter
Clean End-face
One-Click Cleaner SC
Cleaning of Dust (single-mode 10/125 fiber)
Cleaning of Oil (single-mode 10/125 fiber)
Before Cleaning
After Cleaning
Before Cleaning
After Cleaning
Ordering Information
MODEL
One-Click SC, ST, FC
DESCRIPTION
One-Click Cleaner SC, ST, FC (500 cleans)
LENGTH
172 mm (6.88 in)
AFL NO.
BASE
17.5 x 17.5 mm (0.7 x 0.7 in) 8500-05-0001MZ
One-Click LC/MU
One-Click Cleaner LC/MU (500 cleans)
172 mm (6.88 in)
17.5 x 17.5 mm (0.7 x 0.7 in) 8500-05-0002MZ
One-Click ODC
One-Click Mini-100 SC, ST, FC
One-Click Cleaner ODC (outdoor connector, 500 cleans)
One-Click Cleaner Mini-100 SC, ST, FC (100 cleans)
172 mm (6.88 in)
17.5 x 17.5 mm (0.7 x 0.7 in) 8500-05-0004MZ
120.65 mm (4.75 in) 17.5 x 30.2 mm(0.7 x 1.2 in) 8500-05-0005MZ
One-Click Mini-100 LC/MU
One-Click Cleaner Mini-100 LC/MU (100 cleans)
120.65 mm (4.75 in) 17.5 x 30.2 mm(0.7 x 1.2 in)
8500-05-0006MZ
120.65 mm (4.75 in) 17.5 x 30.2 mm(0.7 x 1.2 in)
8500-05-0009MZ
120.65 mm (4.75 in) 17.5 x 30.2 mm(0.7 x 1.2 in)
8500-05-0010MZ
One-Click Mini-500 SC, ST, FC One-Click Cleaner Mini-500 SC, ST, FC (500 cleans)
One-Click Cleaner Mini-500 LC/MU (500 cleans)
One-Click Mini-500 LC/MU
One-Click Ultra Cleaner 2.5
One-Click D-LC
One-Click Ultra Cleaner 2.5 SC, ST, FC
203.2 mm (8 in)
(enlarged cleaning area, 500 cleans)
One-Click Ultra Cleaner D-LC (Duplex LC, 500 cleans x 2) 195 mm (7.7 in)
22.2 x 33.3 mm (0.8 x 1.3 in) 8500-05-0007MZ
18 x 30 mm (0.7 x 1.2 in)
8500-05-0008MZ
NOYES International Sales and Service Contact Information
Available at www.AFLglobal.com/NOYES/Contacts
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
31
© 2008-2012, AFL, all rights reserved. 8500-05-2000 Revision 1F, 2.16.12
Specifications are subject to change without notice.
Cletop Cassette Cleaner Series
The Cletop connector cleaner is a rugged palm-sized cleaner that offers exceptional
performance with a proven track record. The choice of many leading manufacturers
and telecom carries worldwide for nearly 20 years – Cletop is a name you can rely on.
Why Clean Fiber Connectors?
Cletop -S Series
•• Pits and scratches are often caused by dirt
•• Dust, dirt, oils, etc. ,are everywhere and will migrate to exposed connector end-faces
•• Dirty connectors attenuate signal levels and can increase digital bit error rates
•• Always clean both connectors when mating / unmating to avoid contamination transfer
Cletop Cassette Cleaner Options
Cletop Series
•• Cletop Series – Original version (proven reliability)
•• Cletop -S Series – Second generation cleaner offering the same Cletop cleaning performance
with “Drop-in” replacement tape cartridge and ergonomic design that works equally well for
left or right handed operators
•• Type A and -SA – Designed for single 2.5 mm ferrules (SC, FC, ST, & D4)
•• Type B and -SB – Cleans SC, SC2, FC, ST, DIN, D4, MU, LC, MT, MPO/MTP®
without pins, MT-RJ without pins
•• Type MPO – Accepts MPO/MTP connectors with pins
•• Type MT-RJ – Accepts MT-RJ connectors with pins
Features
•• Compact and lightweight design is ideal for use in laboratories,
assembly lines, or in the field
•• Consistent cleaning results without IPA alcohol, which is toxic, flammable,
and leaves a residue on fiber ends (white haze)
•• Excellent anti-static properties for static sensitive applications and
to minimize reattachment of dust to ferrule after cleaning
•• Simple push button shutter operation exposes cleaning tape only when
in use – minimizing unwanted dust
•• Replaceable and cost effective cleaning tape
•• Over 400 wipes per tape
MTP is a registered trademark of US Conec.
© 2007-2012, AFL, all rights reserved. 8500-00-2000 Revision 1D, 2.16.12
Specifications are subject to change without notice.
32
Cletop Cassette Cleaner Series
Specifications
PARAMETER
Size
Weight
VALUE
130 x 75 x 40 mm (5.1 x 3.0 x 1.6 in)
160 g/0.35 lb
Ordering Information
DESCRIPTION
CLETOP – S SERIES
Cletop - SA with Blue Tape
AFL NO.
Cletop - SB with Blue Tape
8500-10-0029MZ
Cletop - SB with White Tape
Replacement Tape Type S - Blue
Replacement Tape Type S - White
CLETOP ORIGINAL SERIES
Cletop Type A with Blue Tape
Cletop Type A with White Tape
Cletop Type B with Blue Tape
Cletop Type B with White tape
8500-10-0016MZ
8500-10-0021MZ
8500-10-0017MZ
Cletop for MT-RJ with pins (White Tape)
8500-10-0032MZ
Cletop for MPO/MTP with pins (White Tape)
8500-10-0033MZ
Replacement Tape Blue
8500-10-0012MZ
Replacement Tape White
8500-10-0015MZ
8500-10-0020MZ
8500-10-0027MZ
8500-10-0011MZ
8500-10-0028MZ
8500-10-0014MZ
© 2007-2012, AFL, all rights reserved. 8500-00-2000 Revision 1D, 2.16.12
Specifications are subject to change without notice.
33
NOTES
NOTES
© 2011, all rights reserved.
BRO-03338
03.31.2014