ElectroVap ELMC2 Steam Bath Specification

Transcription

ElectroVap ELMC2 Steam Bath Specification
Technical manual
Remote control
for
ElectroVap MC2 Steam Bath
1
Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Contents
Description
3-4
Dimensions & Installation
5
Electrical connections
6 to 8
Use & Settings
9 to 13
2
Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Description
6
7
1
2
3
4
5
1.
Steam Production Power On/Off Button
2.
Date / Time Access Setting Button
3.
Hammam light Power On/Off Button
4.
Remote Control On/Off Button
5.
12 V Power Inlet Jack (for optional AC adaptor)
6.
Navigation Pad
7.
OK Button
3
Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Description
The Steam Bath MC Remote Control gives you distant control over your steam bath. Two models
are available :
Model 1 : includes the remote control, a 12V supply transformer, a 3 dry contact control board
and a RS485 board.
Model 1 is capable of :
•
powering manually on or off the steam production or automatically thanks to a weekly
schedule (via terminals 3 & 4 of the steam bath);
•
Offering 3 dry contacts on the 3 contact control board (see under the list of possible
functions).
Model 2 : includes the remote control, a 12V supply transformer, a 8 dry contact control board
and a RS485 board.
This model is capable of :
•
powering manually on or off the steam production or automatically thanks to a weekly
schedule (via terminals 3 & 4 of the steam bath);
•
Offering 8 dry contacts on the 8 contact control board (see under the list of possible
functions).
Remote control
230/12V
Transformer
RS485
board
3 dry contact
board
8 dry contact board
Possible actions with the Steam Bath MC Remote Control :
•
•
•
•
•
•
Switching on and off the steam bath manually or on an automatic scheduled basis;
Pre-set the desired room temperature;
Select the perfume intensity (in case of a perfume device installation);
Switching on or off room light(s);
Switching on or off musics;
Powering ventilation or exhausting air out of the room.
4
Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Dimensions & Installation
DIMENSIONS
95
223
86
35
27
• Weight = 370g
INSTALLATION
Remove the lateral screws of the Remote
Control and dissemble the box. Set the
bottom on wall at the desired place and
mark one of the 4 holes.
Drill a ø 3 or 4mm hole, insert peg and
secure the bottom on wall with a screw.
Make sure that the box is at level and mark
up the other 3 holes. Take the bottom off
wall and drill the holes, insert pegs and
screws and screw them up .
1
Set back the Remote Control front panel
and screw back the two lateral screws.
The installation of the Remote Control is now completed.
Please now wire and set the Steam Bath MC Remote Control.
5
Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Electrical connexions
The wiring of the equipment described under must be made with a 0.75 mm2 maximum
flexible wire.
STEAM BATH 12V TRANSFORMER
Remote control board Ref: 500650/03
0
Transformer
220V/12V
100VA
0
12V
220V
Terminals on DIN
rail of the steam
generator
L
Black terminal to plug
on red terminal (s.a.
attached picture)
N
60
• Attach the 230/12V transformer inside the
electrical compartment of the steam generator
with the supplied set of bolts and nuts.
• Connect transformer wires as per attached
drawing.
61
Red terminal
Red terminal to plug on
On/Off switch
230/12V AC ADAPTOR
Mains socket
230V
6
Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Electrical connexions
The wiring of the equipment described under must be made with a 0.75 mm2 maximum
flexible wire.
RS485 board
Steam generator main board
Ref: 500101/05
RS485 board
Ref: 500800/01
•
•
•
Clamp the RS485 board onto the DIN
rail of the steam generator.
Connect the RS485 grey ply to the
steam generator board
Wire the RS485 3 pin connector to the
Remote Control board J11 connector
with reinforced wire as follows :
485+ on 2
485– on 1
GND on 3
Reinforced wire
GND
(reinforced)
Remote control board Ref: 500650/03
GND
(reinforced)
7
Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Electrical connexions
The wiring of the equipment described under must be made with a 0.75 mm2 maximum
flexible wire.
3 CONTACT BOARD
DEVATEC
• Attach the 3 contact board onto the stand-offs
located under the steam generator main board with
M4 8mm long screws.
• Connect the grey ply of the 3 contact board to the
connector X18 of the steam generator main board.
X4
Réf:500101-05
17
16
15
15V
Transformer
115/15V
X3
14
13
12
X18
11
• The 3 contact board makes possible to connect
three optional devices on terminals : 30-31, 33-34
and 36-37 (NO contact) or terminals : 31-32, 34-35
and 37-38 (NF contact) (perfume device,
disinfectant device, ventilation or other… )
X2
F1:
2A
X12
F4:50mA
6
10
9
8
7
X1
Réf.: 500400-03
K20
X20
30 31 32
X23
K21
K22
NO
NF
NO
NF
NO
NF
X22
X21
36 37 38
33 34 35
37
36
34
33
31
30
30 31 32
8 CONTACT BOARD
33 34 35
36 37 38
• Attach the 8 contact board onto the stand-offs
located under the steam generator main board
with M4 8mm long screws.
• Connect the grey plies of the 8 contact board to
the connectors X16 & X18 of the steam generator
main board.
X16
DEVATEC
REF: 500101_05
• The 8 contact board makes possible to connect
eight optional devices on terminals : 1-2, 4-5, 7-8,
10-11, 13-14, 16-1/, 19-20 and 22-23 (NO contact)
or terminals : 8-9, 11-12, 14-15 or 17-18 (NF
contact) (perfume and disinfectant devices,
ventilation, air exhaust, urgent stop or other… )
X18
NO
NO
1
X11
4
5
19 20
22 23
NO
NF
X10
X12
DEVATEC
REF: 500660/01
X9
RL3
RL5
RL4
RL6
NO
RL1
RL2
X1
X2
1 2
2
NO
NO
4 5
RL7
X3
X4
X5
X6
7 8 9 10 11 12 13 14 15 16 17 18
X7
19 20
NF
NO
NF
NO
RL8
7
X8
22 23
8
8 9
10 11 12
13 14 15
16 17 18
Pictures for illustrating purposes only
NF
STEAM BATH MC REMOTE CONTROL
Use & Settings
DISPLAY SYMBOLS
45°C
Steam generator in run
Hammam lighting on
Steam generator on halt
Hammam lighting off
Room temperature
Perfume on
Music (option)
Pre-set temperature
Auto-timer
Steam generator on-line
Steam generator off-line
DISPLAY READING
45°C
45°C -
+
Mo 00:00
9
Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Use & Settings
Day / time settings
45°C
45°C -
+
Mo 00:00
Pressing button 2 highlights the day and hour information. Press the « OK » button and set the
day by pressing the up or down arrows of the navigation pad.
Then use the right side arrow for selecting the hour digits and set the time with the up and down
arrows of the navigation pad.
Finally, use again the right side arrow for selecting the minute digits. Use the up and down arrows
for increasing or decreasing the time. Press the « OK » button for validation and press again on
button 2 for validation of the day and hour.
2
Auto timer
Your steam generator can be weekly programmed to work on for a certain time at different time of
a day and any day of the week.
The following information will guide you on how to program your steam generator.
1. For entering the schedule menu, press both the
right and left side arrows simultaneously.
10
Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Use & Settings
Auto timer setting
Day
Mo
Tu We Th
Fr
:
Steam unit status
On
10:00
Working period time
Su
Sa
to 15:00
Th 15:12
2. The first day is illuminated : press the down arrow to select the
humidifier status.
3. The status line is illuminated : press the left or right arrow for setting
the humidifier on on or off position.
ou
4. Press the down arrow for setting the working time.
5. The working time is now illuminated : press the « OK » button.
6. For setting the period of time, press the up or down arrow.
ou
7. For selecting the minutes, press the right side arrow.
8. For setting the minutes, press the up or down arrow.
ou
9. Once the working time has been set, press the « OK » button and then
press the down arrow. The working time is no longer illuminated. You
can now set the working time for the following day by pressing the right
side arrow.
10. Process the same way as above for programming the other days.
11. Press Button 2 to exit the program.
2
11
Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Use & Settings
Menu scrolling
or
Temperature setting point
Number of lamps
22°C
22°C
45°C -
1
+
Mo 09:00
Mo 09:00
or
or
ou
Perfume intensity
Music on or off
22°C
-
22°C
Off
+
Mo 09:00
Mo 09:00
or
or
12
Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Use & Settings
Option 1 setting
Option 2 setting
22°C
Opt 1
22°C
Off
Opt 2
Mo 09:00
Off
Mo 09:00
or
or
Option 3 setting
Remote control nb
(if several remote controls)
22°C
Opt 3
22°C
Off
Unit n°
1
Mo 09:00
Mo 09:00
or
or
13
Pictures for illustrating purposes only
Rue Feu St Eloi
76550 Ambrumesnil - France
LR 94104-2
Export Division: tel. +33 (0)2 35 83 06 44 ou +33 (0)2 35 83 03 86
fax. +33 (0)2 35 85 36 72
Email: [email protected] - www.devatec.com
devatec reserves the right to change specifications or design of the equipment described in this borchure
without prior notice.
14
Pictures for illustrating purposes only