Journal - BACnet
Transcription
Journal - BACnet
BACnet Europe ISSN 1614-9572 Journal BACnet – The Standard for Efficient Buildings Frankfurt / Main, April 11 – 16, 2010 Hall 9.0 Stand B60 12 04 / 10 Effiziente Sanierung mit BACnet Efficient Renovation with BACnet 14 ASHRAE spart mit BACnet Energie ASHRAE Adopts BACnet 19 Da steckt Energie drin: Green-IT Energy Optimization with Green-IT 28 Energiesparende Funktionen Energy Saving Functions 52 DESIGO – saves energy efficiently through intelligent building automation Flexible for use in any building or application Come and see us at Light + Building Frankfurt/Main 11.–16.4.2010 Hall 11.0, Stand B55 With the DESIGO™ building automation system, you can significantly reduce energy consumption while at the same time optimize comfort. The system’s high control quality reduces energy consumption and ensures an especially pleasant room climate. Innovative energy saving functions allow you to sustainably preserve resources and therefore to lower costs. And an intelligent, easy-to-operate energy management system identifies saving potentials for all integrated building systems. For you, that means a system that really pays off and that can be used for all applications and expanded as needed – thanks to its high degree of flexibility. For more information, please visit www.siemens.com/desigo Answers for infrastructure. Pictures used show the new court house in Gent, designed in 2007 by the architects Stéphane Beel and Lieven Achtergael from Beel-Achtergael architecten F.V and by Technum. Editorial Notes BACnet Europe Journal ISSN 1614-9572 The BACnet Europe Journal is the European magazine for building automation based on BACnet technology. Experts, practitioners and professionals show the way in applying and developing the BACnet standard – from building automation trends to devices and application projects; from qualification and training to testing and certification; from who’s who in the BACnet community to useful information on events and publications. Special attention is given to members and activities of the BACnet Interest Group Europe (BIG-EU). Distribution This bi-annual and bi-lingual Journal (English / German) can be ordered free of charge by partners, members, media representatives and friends of the BACnet Europe Interest Group (BIG-EU) – registered society. Order the BACnet Europe Journal by E-Mail from [email protected] Online distribution The BACnet Europe Journal is posted as a Portable Document Format (PDF)-File to www.bacnetjournal.org. Editor BACnet Europe Interest Group (BIG-EU), registered society, Droste-Hülshoff-Straße 1 44141 Dortmund Germany Phone: +49-2 31-56 77 72 69 Fax: +49-2 31-42 78 67 32 E-mail: [email protected] URL: www.big-eu.org Executive Board Volker Röhl, Strabag Property and Facility Services GmbH (President), Bill Swan, Alerton / Honeywell (Vicepresident) Gijs de Koning, Regel Partners B.V. (Board Member) Roger Braun, Siemens Schweiz AG (Treasurer) Editorial Office MarDirect Marketing Direct GbR Bruno Kloubert (Editor in chief), Phone: +49-2 31-42 78 67 31 E-mail: [email protected] Advertising MarDirect Marketing Direct GbR Britta von Helden Phone: +49-2 31-56 77 72 69 Fax: +49-2 31-42 78 67 32 E-mail: [email protected] Picture credits BIG-EU, MarDirect and specified companies Copyright © BIG-EU 2010 – Further editorial use of articles in the BACnet Europe Journal is encouraged (!) with reference to the source. Please send a specimen copy to the editor, or if published online, send the URL per mail to [email protected] BACnet® is a registered trademark of the American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc. (ASHRAE) Inhalt – Content 5 6 Christoph Zeller: Steigerung der Effizienz mit BACnet – BACnet Provides Increase in Energy Efficiency BACnet – der Standard für effiziente Gebäude – The Standard for Efficient Buildings is BACnet Anwendungen – Solutions 9 11 14 16 19 21 23 25 28 30 32 35 37 39 41 44 46 48 50 ‘Zukunftssichere’ Frequenzumrichter unterstützen nahtlose Nachrüstung ‘Future-proof’ AC drivers Support Smooth Automation Upgrades Innovatives Unternehmen setzt auf innovative Technik – centrotherm photovoltaics Counts on Innovative Technology Effiziente Sanierung mit BACnet im englischen Dudley College – Dudley College, England: Efficient Renovation with BACnet BACnet von der Feld- bis zur Management-Ebene – BACnet from Field to Management Level ASHRAE Geschäftsstelle spart mit BACnet Energie – ASHRAE Adopts BACnet in Headquarters Building Energiesparkurs in Hotels – Hotels on Course to Save Energy DESIGO Gebäudemanagement für ein exotisches Golfparadies Atlantis – With DESIGO Building Automation and Control System Innovative Klimatisierung im Forschungsprojekt inHaus2, Duisburg Innovative Air Conditioning in the inHaus2 Research Program, Duisburg Da steckt Energie drin: Green-IT – Energy Optimization with Green-IT Mit Energieeffizienzmaßnahmen zu 91 Prozent Einsparung Smart Energy Efficiency Measures Lead to 91 percent Cost Reduction CO2-neutrale Wechselrichter-Fabrik setzt auf BACnet The World’s Largest CO2-neutral Inverter Factory Relies on BACnet BACnet Integration auf allen Ebenen – BACnet Integration at All Levels Südländisches Flair – Shoppen im Mediterraneo Bremerhaven Shopping at Mediterraneo in Bremerhaven – Southern Flair Presented with Charm and Esprit Erstes BACnet Projekt in der Türkei – Istanbul Atatürk International Airport Turkish Debut for BACnet at the Istanbul Atatürk International Airport CargoCity Süd – Gerüstet für weiteres Wachstum – CargoCity South – Ready to Expand Vorne Show, hinten BACnet im FriedrichstadtPalast – Curtain Call with BACnet behind the Scenes Komplexe Automation – einfach umweltfreundlich Simply Green – BACnet / IP Ensures Energy-Efficient Building Automation and Long-Term Flexibility Frischer Wind für Schulen – A Fresh Breeze Sweeps through German Schools Vollintegration von Hocheffizienzpumpen – Kostenreduzierung und Energieeinsparung Full Integration of High-Efficiency Pumps – Cost Reduction and Energy Savings BACnet insight 52 54 BACnet Objekte und Funktionen zum Energiesparen – Energy Saving BACnet Objects and Functions Bessere Qualität von BACnet Projekten II – Higher Quality from BACnet Projects II Produkte – Products 58 59 60 62 63 64 65 67 68 WRF08 BACnet – Komfortable Raumbedienung im ansprechenden Design Comfortable Room Control Highly Design-Oriented Technische Symbiose in der Gebäudeautomation – Technical Symbiosis in Building Automation Innovatives modulares System für mehr Flexibilität – Innovative Modular System for more Flexibility Elesta – Mit dem neuen BACnet Network Controller auf der light+building New Native BACnet Network Controller from Elesta at light+building Funk-Kleinstellantrieb MD15-FTL – Wireless MD15-FTL Small Motor Actuator Protokollwandler mit vielen Möglichkeiten – Versatile Protocol Converter Mit dem neuen Energy///Perfect zu mehr Durchblick – Energy///Perfect for a Clear View DoMooV Automation Server ermöglicht das einfaches Managen von Daten BACnet Server on BMS Standard Open Protocols Gebäudeautomation erfolgreich gestalten – Building Automation Created Successfully BACnet global 69 70 71 72 72 Chinesische Gebäudeautomation integriert BACnet – BACnet Integrated in to Chinese Building Automation Liaison Committee fördert gemeinsame Aktionen – Liaison Committee Sponsors Collaborative Activities Grüner Lichtblick auf der AHR Expo – A Green Ray of Hope at the AHR Expo Der BACnet Standard erobert den Nahen Osten – The BACnet Standard Shines in the Middle East BACnet kommt zur Weltausstellung nach Shanghai – BACnet will be at the World Exposition in Shanghai BACnet Interest Group Europe 73 74 75 77 77 78 GebäudeEffizienz Paris – Efficacité énergétique du Bâtiment – Dialogue 2010 Paris interclima+elec spiegelt wachsenden BACnet Bedarf – interclima+elec Reflects the Growing Demand for BACnet Effiziente Gebäudetechnik³ – Efficient Building Services Engineering³ Investitions- und Betriebskosten senken – Reducing Investment and Operating Costs Willkommen in der BIG-EU – Welcome to the BIG-EU BACnet Kalender – Calendar of BACnet Events BACnet Europe ISSN 1614-9572 Journal BACnet – The Standard for Efficient Buildings Frankfurt / Main, April 11 – 16, 2010 Hall 9.0 Stand B60 12 04 / 10 Effiziente Sanierung mit BACnet Efficient Renovation with BACnet 14 Titelbild Cover picture Wechselrichter-Fabrik Inverter factory SMA Solar Technology AG, Kassel, Germany Auf www.bacnetjournal.org als Download verfügbar. All issues can be downloaded from www.bacnetjournal.org. ASHRAE spart mit BACnet Energie ASHRAE Adopts BACnet 19 Da steckt Energie drin: Green-IT Energy Optimization with Green-IT Energiesparende Funktionen Energy Saving Functions 52 28 © SMA Solar Technology AG BACnet Europe Journal 12 04/10 3 Smart – wireless – no batteries: EasySens® in combination with BACnet MS/TP communication protocol The interoperable EasySens system makes your operation as easy as possible. With only one BACnet gateway the evaluation of up to 9 different wireless sensors and switches is possible. No complex wiring is needed any more. Thus, you are fully flexible with regard to your interior design. › Advantages at a glance: · wireless · no batteries · maintenance-free · cost-effective · interoperable › SR04PST Room Operating Panel Please visit us in Hall 9.0 Thermokon Main Stand D50 › Wireless Switch »mini« at a reasonable price Thermokon design in pure white, anthracite, aluminium, pure white glossy 11. – 16.04.2010 Frankfurt EnOcean Partnership Stand B40 LONMark Partnership Stand E10 BACnet Partnership Stand B60 Steigerung der Effizienz mit BACnet BACnet Provides Increase in Energy Efficiency Liebe Leser, Energieeffizienz ist eines der Schlüsselworte der Zukunft. Obwohl beim Weltklimagipfel vom letzten Dezember die hochgesteckten Ziele nur teilweise erreicht wurden, erkannte die Staatengemeinschaft im rechtlich nicht verbindlichen „Copenhagen Accord“ den Klimawandel als die größte Herausforderung der Menschheit an. Klar ist, dass wir in Europa den Energieverbrauch pro Kopf drastisch senken müssen. Welche Auswirkungen hat dies nun für uns? Dear Reader, Energy efficiency is one of the watchwords for the future. Although the ambitious goals set for last December’s world climate summit were achieved only in part, the Copenhagen Accord adopted by the international community, while not legally binding, acknowledged that climate change is the greatest challenge facing humanity. It is clear that we in Europe must drastically cut our per capita energy consumption. So how is this going to affect us? Die Erfüllung dieser Anforderung wird in Zukunft nicht leichter werden und bedingt ausgefeilte Regelungs- und Steuerungstechnik. Auch in Zukunft möchten wir auf den heutigen Komfort nicht verzichten und werden eine Steigerung der Energieeffizienz in der geforderten Größenordnung allein durch bessere Isolation der Gebäude nicht erreichen können. Daher müssen die verschiedenen Gewerke (HLK, Licht, Jalousien, etc.) verstärkt miteinander Daten austauschen. Sollen Gateways mit all ihren Problemen vermieden werden, so müssen diese ein gemeinsames Protokoll sprechen. Mit BACnet steht ein Protokoll zur Verfügung, das schon heute von verschiedenen Gewerken unterstützt wird. Meeting this requirement is not going to become any easier as time goes on; it calls for sophisticated measuring and control technology. Since we are unwilling to give up our present levels of comfort, and the necessary increase in energy efficiency cannot be achieved merely by improving the insulation of buildings, it follows that data exchange among the various systems (HVAC, lighting, blinds, etc.) has to be stepped up. If we are to avoid gateways – and all the problems that they entail – the equipment systems will have to ‘speak’ a common protocol. BACnet provides us with a protocol that is already supported by a variety of different systems. Damit in Zukunft noch weitere Gewerke integriert werden können, wird der BACnet-Standard ständig erweitert. Eindrucksvoll veranschaulicht dies die Anzahl der Addenda: Betrug die Zahl der veröffentlichten Addenda zwischen 2001 und 2008 insgesamt elf, so waren es allein im letzten Jahr sieben. Acht weitere stehen unmittelbar vor der Veröffentlichung. Darunter befinden sich neben Verbesserungen der Verständlichkeit auch gewichtige Ergänzungen, wie Wirelessoder XML-Spezifikationen für den Datenaustausch. The BACnet standard is constantly being extended so that even more systems can be integrated in the future. This is strikingly illustrated by the number of addenda to the standard: a total of eleven were published between 2001 and 2008, with seven more in 2009 alone and eight more due to be published very shortly. As well as changes that make the text easier to understand, these addenda include important additions such as wireless or XML specifications for data exchange. Was unterscheidet nun eine effiziente Immobilie von ihren „normalen“ Schwestern? Die Behauptung, ein Gebäude sei energieeffizient, ist schnell aufgestellt. Wie kann dies jedoch nachgewiesen werden? Zu diesem Zweck müssen Verbrauchsdaten ausgewertet werden und um innere Lasten korrigiert, mit Benchmarks und meteorologischen Daten verglichen werden. Zum Sammeln der Rohdaten helfen die seit 2001 vorhandenen BACnet-Trendlog Objekte. Einheitliche Schnittstellen erleichtern das Zusammenfassen der schon heute in vielen Reglern enthaltenen Primärdaten. What are the differences between an efficient building and its ‘normal’ counterparts? It takes no time at all to claim that a building is energy-efficient, but how can this be proven? To do this, consumption data must be evaluated, corrected for internal loads and then compared with benchmarks and meteorological data. Since 2001, BACnet Trendlog objects have been available to collect the raw data. Uniform interfaces make it easier to collate the primary data that are already included in many of today’s controllers. In Zukunft dürften für diese Zwecke auch SOAP basierte Schnittstellen an Bedeutung gewinnen, welche im BACnetStandard 2008 mit den Webservices eingeführt wurden. Es bleibt also spannend in unserer Branche. Ich lade Sie ein, sich auf der light+building über die neuesten Entwicklungen zu informieren. SOAP-based interfaces are also likely to become more important for these purposes in the future; they were introduced with the web services in the 2008 BACnet standard. All in all, our sector can continue to expect some exciting developments. See you at the light+building where we share the newest progress. Christoph Zeller Fr. Sauter AG Leiter der BIG-EU Arbeitsgruppe Technik (WG-T) Head of the BIG-EU Working Group Technique (WG-T) BACnet Europe Journal 12 04/10 5 BACnet Interest Group Europe BACnet – der Standard für effiziente Gebäude The Standard for Efficient Buildings is BACnet Planer und Integratoren für offene BACnet Systeme sind gefragt. Kaum eine Ausschreibung ohne BACnet – der herstellerunabhängige Standard wird zur festen Größe für das effiziente Gebäude. Auf der light+building zeigen 22 Mitglieder der BIG-EU was qualifizierte Fachingenieure, aber auch Anwender und Facility Manager wissen müssen. Planners and integrators for open BACnet systems are in demand. Hardly any tender offer is made without BACnet – this vendor-independent standard is becoming a fixed factor for efficient buildings. At light+building, 22 members of the BIG-EU will exhibit everything that skilled engineering specialists, users and facility managers need to know. Energiemanagement, Komfort und Sicherheit lassen sich mit dem offenen Kommunikationsstandard effizient integrieren. Das ist nachhaltige Gebäudeautomation par excellence, zu sehen in Halle 9.0 am Stand B60. BIG-EU forciert Dialog mit Integrationsplanern BIG-EU Präsident Volker Röhl kündigt weitere Schritte an, um den Engpass beim BACnet Know-how zu überwinden: „Wir beginnen auf der light+building einen neuen Dialog mit den Inte- grationsplanern und Anwendern, den wir noch in diesem Jahr intensivieren.“ Führend sind hier die Deutsche Bahn, FRAPORT, STRABAG sowie AMEV, der Arbeitskreis öffentlicher Bauverwaltungen. Sie sind längst in die notwendige Auseinan- April 11-16, 2010 Hall 9.0 Stand B60 dersetzung mit BACnet eingestiegen. Die Angebote zum effizienten Umgang mit Energie wachsen. Besonders die Gebäude bieten mit 40 Prozent Anteil am Primärenergieverbrauch ein enor Ihre Aussteller auf der light+building 2010 Your exhibitors at light+building 2010 Die technologie-unabhängige Integration der Gebäude systeme geht weit über die Heizungs-, Lüftungs- und Klimasteuerung (HLK) hinaus. BACnet erschießt auf einfache Weise neue Anforderungen wie Energiemanagement, Funkanwendungen, Sicherheit, Zutrittskontrolle. Auf dem 180 qm großen Stand präsentieren 22 BIG-EU Mitglieder ihre BACnet Komponenten. The technology-independent integration of building systems goes far beyond heating, ventilation and air conditioning control (HVAC). BACnet aims for easy methods to accommodate new requirements such as power management, wireless applications, security, and access control. 22 BIG-EU members will present their BACnet components at the 180 sqm booth. Beyond Comfort 6 BACnet Europe Journal 12 04/10 Willkommen am neuen Ausstellungsstand der BIG-EU. Die konzentrische Anordnung der Aussteller steht für die Integration aller Komponenten rund um das gemeinsame Ziel: effiziente Gebäude durch intelligente Automation. BACnet ist der einzige im Konsens entwickelte Standard für integrierte Gebäudeautomation. Welcome to the BIG-EU’s new exhibi tion booth. The concentric arrangement of exhibitors stands for the integration of all components toward a common goal: efficient buildings through intelligent automation. BACnet is the only standard developed in consensus for integrated building automation systems. mes Potenzial, die Energieeffizienz zu verbessern und durch Reduzierung der CO2-Belastung etwas für den Klimaschutz zu tun. Besonders schnell und nachhaltig wirkt hier der Einsatz von intelligenter Gebäude automation. Am Gemeinschaftsstand zeigen die Mitglieder, warum BACnet der Standard für effiziente und nachhaltige Gebäude ist. Daten austauschen zum Energiesparen Der BACnet Standard ist die Basis, damit Geräte ihre Daten zum Energiesparen austauschen können – dank der Offenheit von BACnet auch im Verbund mit Komponenten anderer Hersteller. BACnet ermöglicht die einfache herstellerunabhängige Integration einer zunehmenden Zahl von Gewerken. Neben Heizung, Klima und Lüftung werden auch Energiemanagement, Funkanwendungen, Sicherheit, Zutrittskontrolle und weitere Funktionen eingebunden. Die technologie-unabhängige Integration schafft effiziente und nachhaltige Gebäudesysteme in Bezug auf Energieverbrauch, Komfort und Sicherheit. Damit wächst die Bedeutung von BACnet beim Bau und bei der Sanierung weiter. Die Mitglieder der BIG-EU sind führend in der Gestaltung offener Systeme. Auf der light+building zeigen sie, wie BACnet die Systemintegration vereinfacht und den Wert von Immobilien steigert. Energy management, comfort and safety can be effectively integrated into the open communication standard. That is sustainable building automation par excellence, presented in Hall 9.0 at Stand B60. BIG-EU accelerates dialogue with integration planners BIG-EU President Volker Röhl announces additional steps to overcome the holdup in BACnet know-how: “At light+building we will commence a new dialogue with integration planners and users which we will intensify in this year.” The leading groups are Deutsche Bahn, FRAPORT, STRABAG, as well as AMEV, the working group of public building authorities. They have long since entered into the necessary analysis of BACnet. The offer of efficient use of energy is growing. Buildings in particular, with a 40 percent share of primary energy consumption, offer a huge potential for climate protection by improving energy efficiency and reducing CO2 emissions. The use of intelligent building automation works especially quickly and sustainably. At the joint booth members will demonstrate why BACnet is the standard for efficient and sustainable buildings. Data exchange for saving energy The BACnet standard is the foundation with which devices can exchange data in order to save energy – thanks to the openness of BACnet even when combined with components from other manufacturers. BACnet allows easy vendorindependent integration of a growing number of trades. In addition to heating, air conditioning and ventilation applications, energy management, wireless applications, security, access control and additional functions are integrated as well. The technology-independent integration creates efficient and sustainable building systems in terms of energy consumption, comfort and safety. Thus the importance of BACnet in construction and rennovation continues to grow. The members of the BIGEU are leaders in the configuration of open systems. At light+building they will demonstrate how BACnet simplifies system integration and increases the value of a real estate. BACnet Europe Journal 12 04/10 7 Wo von offener Gebäudeautomation die Rede ist, spricht man von BACnet. Wo diese auch modular, mitwachsend und energieeffzient ist, von SAUTER. Learning, understanding, planning and specifying building automation management with BACnet Zurich 18th May 2010 or Deadline f n: registratio . April 19 th Training Introduction to building automation via BACnet ISO 16484-5 • • • • • Basics of interoperability Why BACnet? Object types and services Project planning Conformance testing, BTL Logo and European Certification The training will be conducted in English SAUTER EY-modulo 5: Mit BACnet/IP. The training is designed specifically for the interests and needs of the technical service providers, developers, project engineers, planners and facility managers designed Training venue 5 Km from Zurich Airport, World Trade Center Zürich AG Leutschenbachstrasse 95, 8050 Zürich Energieeffizienz, Offenheit und Wirtschaftlichkeit. Modul für Modul für Modul. Modulare, native BACnet-Stationen der SAUTER EY-modulo 5 Familie sind in jeder Hinsicht die intelligente Lösung für alle Anforderungen im Gebäudemanagement. Mit optimalen Funktionsmodulen, integrierter Web-Anbindung sowie flexibler Raumautomation, setzt SAUTER neue Massstäbe. Frei programmierbar, sorgt SAUTER EY-modulo 5 für optimale Systemintegration (z.B. M-Bus, Modbus) Expert supervision Contact and Registration Britta von Helden [email protected] Tel. +49 231 567772-69 Room reservation via HRS und reibungslosen Betrieb. Erfahren Sie mehr über seine vielfältigen Möglichkeiten: www.sauter-controls.com Systems Components Services Facility Management Anwendungen Solutions ‘Zukunftssichere’ Frequenzumrichter unterstützen nahtlose Nachrüstung ‘Future-proof’ AC drivers Support Smooth Automation Upgrades Mit dem standardmäßig integrierten nativen BACnet ermöglicht der Standard Drive von ABB bei HLK-Applika tionen eine größere Flexibilität. Bei der Anlagenmoderni sierung kann dieser Antrieb zu zeitlichen und finanziellen Einsparungen beitragen. Peikko Finland nutzt diese Vorteile bei der Modernisierung des Gebäudemanagementsystems (GMS) in einer Produktionsstätte. With native BACnet embedded as standard, ABB’s standard drive for HVAC offers great flexibility. It can help to deliver significant savings in time and money when systems are changed. Peikko Finland realized these benefits when the Building Management System (BMS) in one of its production units was upgraded. Peikko Finland Oy stellt am Standort Lahti Bauelemente her. 2006 hat das Unternehmen eines seiner Produktionsgebäude erweitert, jedoch schon bald festgestellt, dass das GMS nicht zuverlässig genug war und aufgrund hauseigener Technologie die Geräteintegration erschwerte. Deshalb erhielt Siemens Building Technologies den Auftrag, das GMS mit einem BACnet-System nachzurüsten. Die vorhandene HLK-Anlage wurde mit vier Standard Drive-Frequenzumrichtern für HLK von ABB als Antriebe für drei Klimageräte realisiert. Dies erwies sich als gute Wahl, die Frequenzumrichter wurden bereits kurz nach der Markteinführung 2003 standardmäßig mit nativem BACnet ausgestattet. Es war der erste Frequenzumrichter, der dem BACnet-Standard entsprach und von den BACnet Testing Laboratories (BTL) die WSPCertZertifizierung erhielt. Problemlose Integration Embedded BACnet bedeutet, dass die vorhandenen Antriebe ohne zusätzliche Planungsarbeit und aufwendige Verkabelung in das neue GMS integriert werden können. Es wurde durch eine Verkettung der Antriebe ein BACnet MS / T PTeilnetz (Master-Slave / To- ken Passing) eingerichtet. In einem der Antriebe wurde ein BACnet-Router von ABB installiert. Nur ein neues Ethernet-Kabel musste zum Anschluss des Routers an den Direct Digital Controller (DDC) installiert werden, so dass Änderungen an dem vorhandenen Ethernet-Backbone vermieden wurden. Der in die Frequenzumrichter integrierte Assistent vereinfachte die BACnet-Inbetriebnahme. Peikko Finland plant die Erweiterung des BACnetSystems auf alle Gebäude am Standort Lahti. Peikko Finland plans to expand the BACnet system to all the buildings at its Lahti site. BACnet Europe Journal 12 04/10 9 Anwendungen Solutions Peikko Finland Oy manufactures construction components at its base in Lahti. The company expanded one of its production buildings in 2006, but it was soon realized that the BMS was not sufficiently reliable and, due to proprietary technology, did not support smooth device integration. Siemens Building Technologies was therefore commissioned to upgrade the BMS with a BACnet system. Der Standard Drive-Frequenzumrichter von ABB für HLK-Applikationen verfügt standardmäßig über natives BACnet. The ABB standard drive for HVAC has native BACnet embedded as standard. Der BACnet-Router überträgt Telegramme zwischen den BACnet MS / T P-Teilnetzen der Frequenzumrichter und dem BACnet / I P-Netz des GMS. Es handelt sich um ein steckbares Modul, das in den Frequenzumrichter hineinpasst und mit dem früheren Standard-Drive von ABB bei HLK-Applikationen kompatibel ist. Die Konfiguration erfolgt einfach über einen Standard-Browser. Die Einbindung eines Routers in das Netz bedeutet, dass die Frequenzumrichter von den übergeordneten Stufen des Systems auch dann erkannt werden, wenn es keinen Gebäude-Controller gibt. Über den Router kann der Bediener von seinem Arbeitsplatz aus auf alle Antriebsparameter zugreifen. Dadurch erhöht sich die Flexibilität bei der Wartung. Darüber hinaus erhält der Inbetriebnahme-Ingenieur die Möglichkeit, den Frequenzumrichter beim Austausch der Regler zu überwachen und zu steuern. Fernzugriff Das neue GMS nutzt die integrierte Funktion für die vorausschauende Wartung des ABB-Antriebs, die beim Auftreten eines Problems eine Warnmeldung ausgibt. Der Fernzugriff auf das System erfolgt per Web über einen sicheren VPN-Tunnel. Außerdem wird die gleiche Ethernet-Infrastruktur wie bei dem Büronetz des Gebäudes verwendet. Das GMS umfasst die Siemens Energy Management Control (EMC). Dank BACnet stehen an jedem Arbeitsplatz die Angaben zum Energieverbrauch und andere Daten zur Verfügung. Das BACnet-System hat alle Erwartungen von Peikko Finland erfüllt. Es ist geplant, auch die anderen fünf Gebäude des Standorts in das System zu integrieren. 10 BACnet Europe Journal 12 04/10 The existing HVAC system had been implemented using four ABB standard drives for HVAC to operate three air handling units (AHUs). This proved a very fortunate choice, as the drive has had native BACnet embedded as standard almost since it was launched in 2003. It was the first variable speed drive to conform to the BACnet standard, and to receive BACnet Testing Laboratories (BTL) approval by WSPCert certification. Smooth integration Embedded BACnet meant the existing drives could be easily integrated into the new BMS without the need for additional engineering work or extensive cabling. A BACnet MS / TP (master-slave / token passing) sub-network was created using ‘daisychain’ cabling between the drives, and an ABB BACnet router was installed in one of the drives. Only one new Ethernet cable had to be provided to connect the router to the direct digital controller (DDC), avoiding the need for changes to the existing Ethernet backbone. The drives’ built-in assistant simplified the task of commissioning the BACnet protocol. The BACnet router transfers messages between the drives’ BACnet MS / TP subnetwork and the BMS BACnet / IP network. It is a snapon module which fits inside the drive and is backwards compatible with ABB’s older standard drive for HVAC applications. The drive can easily be configured using a standard web browser. Incorporating a router into the network means that the drives are visible to higher levels in the system – even if there is no building controller. The router enables operators to access all the drive parameters from the workstation and therefore provides extra flexibility for maintenance. It also gives the commissioning engineer the option to monitor and control the drive while replacing the controllers. Remote access The new BMS utilizes the ABB drive’s predictive maintenance function to trigger an alarm if a problem occurs. The system is remotely accessible over the Internet via a secure VPN tunnel, and it uses the same Ethernet infrastructure as the office network in the building. The BMS incorporates Siemens Energy Management Control (EMC) and, thanks to BACnet, energy consumption and other data is easily available from any workstation in the system. The BACnet system has met all Peikko Finland’s expectations, and there are plans to expand it to bring the other five buildings at the same site into one overall system. Riku Kalliomaa ABB Oy, Drives (Helsinki, Finland) Global Market Manager HVAC [email protected] www.abb.com / drives Anwendungen Solutions Sitz der centrotherm photovoltaics in Blaubeuren. Office of centrotherm photovoltaics in Blaubeuren. Innovatives Unternehmen setzt auf innovative Technik centrotherm photovoltaics Counts on Innovative Technology Für den Neubau einer Produktionshalle, eines Verwaltungs gebäudes und einer Cafeteria setzt centrotherm photovoltaics auf die innovative Gebäudemanagementund Gebäudeautomationstechnik auf BACnet-Basis aus dem Hause DEOS control systems. For the construction of a new production hall, administration building and cafeteria, centrotherm photovoltaics relies on innovative building management and building automation technology based on BACnet from DEOS control systems. Die centrotherm photovoltaics AG ist einer der weltweit führenden Anbieter von Technologie und Equipment für die Herstellung von Solarsilizium, von kristallinen Solarzellen und CIGS -Dünnschichtmodulen. Das Unternehmen stattet namhafte Solarunternehmen mit schlüsselfertigen („Turnkey“-) Produktionsli- nien und Einzelanlagen aus. Durch das starke Wachstum im Jahr 2009 – das Unternehmen beschäftigt rund 1.100 Mitarbeiter – war es erforderlich, den Standort Blaubeuren zu erweitern. Der erste Abschnitt, der Bau einer Produktionshalle, wurde im zweiten Quartal 2009 fertig gestellt. Das Verwaltungsgebäude und die Cafeteria waren im Dezember 2009 bezugsfertig. Einheiten kommunizieren in Echtzeit Bei der technischen Gebäudeausrüstung setzte man auf einen sehr hohen Standard. Dreizehn Lüftungsanlagen und weitere Anlagen zur Wärme- und Kälteversorgung sind Teil des BACnet Automationssystems und in einer COSMOS 4000 OPEN Automationsstation integriert. Ebenfalls sind aus dem Gewerk Elektro 28 WAGO BACnet / I P Building Controller in das COSMOS-System integriert. Durch diesen Schritt konnte die gesamte Beleuchtung und Jalousiesteuerung visualisiert werden. Beeindru- BACnet Europe Journal 12 04/10 11 Vom Pionier zum Technologieführer » Mehr als 43 Jahre Erfolg in der Gebäudeautomation » Spitzentechnologie „totally made in Germany“ BACnet Antriebe BACnet IO-Module BACnet Controller Technologie für intelligente Gebäude! Birkenallee 113 D-48432 Rheine Tel. +49 (0)5971 91133-0 Fax +49 (0)5971 91133-95 [email protected] www.deos-ag.com Ein Unternehmen der DEOS AG Anwendungen Solutions Die Gebäudeleittechnik COSMOSweb der Firma DEOS control systems. Convenient and easy web-based operation with the native BACnet BMS (COSMOSweb) ckend ist, dass bei der Aufschaltung kein spürbarer Geschwindigkeitsverlust bei der Datenkommunikation entsteht. Die Einheiten des Systems kommunizieren in Echtzeit. Energieeffizient bis hin zur Einzelraumregelung Zusätzlich aufgeschaltet sind zwei Rechenzentren über BACnet / I P. Weitere Bus-Protokolle wie EIB, M-Bus, Modbus und P90 von Kieback&Peter sind auf den leistungsstarken COSMOS 4000 OPEN Controllern in der Automationsebene aufgeschaltet. Die Energieeffizienz zieht sich durch das ganze System, bis hin zur Einzelraumregelung im Verwaltungsgebäude. Durch die kompakte Baugröße der COSMOS IO-Module wurden diese dezentral in den Räumen untergebracht. Diese kommunizieren mit dem BACnet-Netzwerk über den CAN-Bus. Die Raumautomation steuert Temperatur, Beleuchtung und Sonnenschutz in den Büroräumen genau nach den Erfordernissen der Mitarbeiter. Komfortable webbasierte Bedienung Auf der Managementebene wurde die webbasierte native BACnet GLT (COSMOweb) von der Firma DEOS control systems eingesetzt. Die GLT COSMOweb ermöglicht eine komfortable und einfache webbasierte Bedienung. Die Anforderungen des Endkunden werden in Bezug auf ei- ne hochflexible und einfache Bedienung in jeder Hinsicht erfüllt. Zurzeit sind 6.000 Datenpunkte über das Sys tem aufgeschaltet. Alleine 1.200 BACnet Objekte wurden in das System eingepflegt. Das Gesamtsystem, vom DDC-Controller bis zur GLT, wurde in das ITFirmennetzwerk integriert und ermöglicht durch die webbasierte GLT eine Bedienung von allen Arbeitsplätzen aus. Die Bedienung erfolgt dabei über den Internet Explorer. centrotherm photovoltaics AG is a worldwide leading supplier of technology and services for the photovoltaics industry. They provide renowned solar companies and newcomers with turnkeyproduction lines and individual plants for the fabrication of crystalline solar cells, modules and thin film modules. Due to strong growth (1,100 employees in 2009), it was necessary to expand the Blaubeuren location. The first stage, the building of the production hall, was completed in the second quarter of 2009. The administration building and the cafeteria were ready for occupancy in December 2009. Units of the system communicate in real-time For the technical building equipment, the standard was set very high. Thirteen ventilation systems and other plants for heat and cooling supply are part of the BACnet automation system and are also integrated in the COSMOS 4000 OPEN. Furthermore, 28 WAGO BACnet / IP building controllers were integrated in the COSMOS system. By taking this step the complete lighting and blind control is visualized. Also impressive is that there is no noticeable loss of speed in the data communication during connection. The units of the system communicate in real-time. Energy efficiency even in single room control Additionally two computer centres were connected via BACnet / IP. Further Bus-protocols like KNX, M-Bus, Modbus and P90 from Kieback&Peter were implemented on the powerful COSMOS 4000 OPEN controller in the automation level. The energy efficiency is represented through the complete system, down to single room control in the administration building. Due to the compact size of the COSMOS IO-modules it was possible to place them decentralized in the rooms. They communicate with the BACnet network via CANBus. The room automation controls the temperature, the lighting and the sun protection in the offices according to the requirements of the employees. Comfortable and easy web-based operation On the management level the web-based native BAC- net BMS (COSMOweb) was installed by the company DEOS control systems. The COSMOweb system allows a comfortable and easy webbased operation. No wish will be overlooked concerning the desires of the end-customers for highly flexible and easy operation. At this moment 6,000 data-points are connected on the system. About 1,200 BACnet objects were programmed to the system. The overall system, from the DDC-Controller to the BMS, was integrated into the corporate IT network and made operation from all workplaces possible via the web-based BMS. This operation is done via Internet Explorer. Klaus Keck Leiter der Niederlassung Rhein-Main Plüth Gebäudeautomation Tochter der DEOS AG [email protected] www.deos-ag.com BACnet Europe Journal 12 04/10 13 Anwendungen Solutions Effiziente Sanierung mit BACnet im englischen Dudley College Dudley College, England: Efficient Renovation with BACnet Das Dudley College in den West Midlands, England, hat kürzlich Elesta’s natives BACnet Gebäudeautomationssystem für die Sanierung ihrer bestehenden Systeme ausgewählt. Dudley College in the West Midlands, England has recently selected Elesta’s native BACnet building automation system to upgrade their existing building automation systems. Das Dudley College ist eine allgemeine Weiterbildungseinrichtung, die den Bezirk Dudley und das Umland des „Black Country“ betreut. Das College bietet Ausbildungen und Schulungen an, die sowohl die wirtschaftliche Regenerierung als auch den Bildungsstand der lokalen Arbeitskräfte stärkt und damit den wirtschaftlichen Wohlstand in der Region. Mit fünf Standorten verteilt sich das Dudley College über das Stadtgebiet. Das Heizsystem wird über vier Heizzentralen in den Standorten Mons Hill- und Castle View Campus gespeist. Hier musste die Gebäudeautomation in jeweils zwei Heizzentralen saniert werden. Die Heizzentralen waren bisher mit Geräten der Firmen JEL und Satchwell Controls ausgestattet, die über Modem anbindungen mit der existierenden Gebäudeleittechnik Dudley MBC verbunden waren. Mit der Sanierung der Gebäudeautomation wurde Elesta’s Premium Systempartner Clarkson Controls in Worcestershire beauftragt. Die Finanzierung des Projektes wurde über ein „Learning & Skills“ Zuschuss des Rates sichergestellt. Da die existierenden Schaltschränke im guten Zustand und konform zu den gültigen Standards waren und um die Kosten und den zeitlichen Ablauf zu optimieren wurde entschieden, die bestehenden Schaltschränke Das Dudley College stärkt den lokalen Bildungsstand. The Dudley College underpins local skills. 14 BACnet Europe Journal 12 04/10 zu belassen und nur die Gebäudeautomation zu erneuern. Dies führte zu einer erheblichen Reduzierung der Amortisationszeit, die sich durch die Integration einer neuen Gebäudeleittechnik auf der Managementebene zur Visualisierung, Bedienung und Optimierung der Anlage weiter verbesserte. Natives BACnet Für das Gebäudeautomationssystem wurden die modernen Master Controller RCO700D-M mit dem B-BC BACnet Geräte Profil ausgesucht. Die Controller unterstützen die BACnet-Varianten Ethernet, IP, MS / TP und PTP. Die modularen Eingangs- und Ausgangsmodule integrierter Handbedienebenen sind direkt mit den Master Controllern verbunden. Der Austausch der bestehenden Controller durch die wesentlich kompakteren Elesta Controller konnte unter Berücksichtigung der bestehenden Verdrahtung problemlos in den existierenden Schaltschränken durchgeführt werden. Die Heizzentralen wurden sukzessive saniert, um die Wärmeversorgung und Bedienung während der Sanierung sicher zu stellen. Anbindung über BACnet / IP Die kurzen Umrüstzeiten wurden durch die Tatsache unterstützt, dass die bestehenden Sensoren problemlos angebunden werden konnten. Elesta’s universelle Eingangsmodule unterstützten alle handelsüblichen Sensoren. Die vier Heizzentralen mit Elesta’s RCO D Controllern wurden dann über das lokale Netzwerk mit der Gebäudeleittechnik verbunden. Die Anbindung erfolgte über das BACnet / I P-Protokoll. Durch die Nutzung der vorhandenen IP-Netzwerkinfrastrukturen konnten die vorher für das existierende System notwendigen drei Telefonleitungen still gelegt werden. Dies führt zu zusätzlichen jährlichen Einsparungen. Zur Visualisierung, Bedienung und Optimierung der Anlage wurde Clarkson Controls BOW zentral auf der Managementebene installiert. Anwendungen Solutions Das Dudley College in den West Midlands, England. Dudley College in the West Midlands, England. Dudley College is a continuing education college serving the borough of Dudley and the wider area of the Black Country. The College provides education and training that both underpin the economic regeneration and skill base of the local workforce, thereby contributing to the prosperity of the area. The college is distributed over five campuses in the municipal area of Dudley. The heating system for the college emanates from four boiler houses around the two campuses, Mons Hill and Castle View, where the existing building automation system had to be upgraded. The boiler houses previously had a mixture of JEL and Satchwell Controls been fitted with, most of which had failed over time, along with the modem links back to the Dudley MBC Building Management System. The contract for the upgrade was awarded to Elesta’s Premium System Partner, Clarkson Controls based in Worcestershire. The funding for the works were obtained via a Learning & Skills Council Grant. The existing motor control panels were in good repair and up to current standards, so in order to keep costs under control and regain time and temperature control quickly it was decided to just update the building automation system. By doing this it also helped to reduce the pay back times to qualify for the LSC grant monies. By incorporating a central building control system at the management level for constant visualisation, operation and optimisation, this further enhanced the payback times needed. Native BACnet For the building automation system the modern Master Controllers RCO700D-M with the B-BC BACnet device profile were selected. The controller supports the BACnet variants Ethernet, IP, MSTP and PTP. The modular input and output modules were directly con- nected to the master controllers. The output modules were provided with integrated manual override ability. It was an easy matter to remove the old larger style “mother board” controllers and replace with the compact ELESTA controllers on purpose-built back plates – thus utilizing the existing controller housings and wiring. Each boiler house was changed over separately in order to give local stand alone control as quickly as possible, whilst maintaining services. Connection over BACnet / IP This quick change-over time was further assisted by being able to retain the existing sensors – ELESTA’s universal input modules can be set to accept all sensor types. The four motor control panels, which by now contained the ELESTA RCO-D controllers, were then connected over BACnet / I P via the local network back to the building control system computer. By using the sites network infrastructure the three tele phone lines on the old system were disposed of, making annual line rental savings. Clarkson Controls dynamic BACnet visualisation software was then utilised to provide access into the system for the client. Torsten Szypulski ELESTA GmbH building automation [email protected] www.elesta.de BACnet Europe Journal 12 04/10 15 Anwendungen Solutions BACnet von der Feldbis zur Management-Ebene BACnet from Field to Management Level Eine der größten Grundwasser-Geothermieanlagen Europas beliefert den Büropark Bonner Bogen und das zugehörige fünf Sterne Hotel mit Wärme- und Kälteenergie. Die Energiezentrale und die zentralen TGA-Anlagen des Hotels wurden von der Hermos AG von der Feld- bis zur Leitebene automatisiert. Dreizehn Steuerungen des Typs PCD3 M5540 der Firma Saia Burgess kommunizieren gewerkeübergreifend mittels BACnet-Protokoll. Dies nicht nur untereinander und mit der Hermos Leittechnik FIS #, sondern auch mit 29 Frequenzumrichtern des Typs ACH550 der Firma ABB. Die Vernetzung erfolgte via Ethernet und EIA-485. One of the largest ground water geothermal energy plants in Europe supplies the “Bonner Bogen” office park as well as the attached 5-star hotel with energy for heating and cooling. The energy center and the central TGA plant of the hotel were automatized from field to management level by Hermos AG in Mistelgau (Germany). 13 PDC3 M5540 controllers produced by SAIA Burgess communicate via BACnet protocol not only with each other and the management software FIS# but also with 29 frequency converters ACH550 produced by ABB. The network connection between them was made using Ethernet and EIA-485. Die Versorgung des Hotels mit Wärme und Kälte übernimmt die im Keller befindliche Energiezentrale des Bonner Bogens. Sie bezieht die Energie aus dem Grundwasser, welches über drei Saug- und Schluckbrunnenpaare gewonnen wird. Mit Hilfe dezentraler Anschaltbaugruppen des Typs Saia T760 werden die entsprechenden Pumpen und Klappen der Brunnen gesteuert. Die über Profi-S-Net bezogenen Daten der DP-Baugruppen werden von der Saia PCD3 Steuerung dem BACnet Netz zur Verfügung gestellt. So ist es dem Bediener möglich, direkt vom Leitsystem FIS# entweder auf die gesamte Anlage durch Sollwertanpassung oder auf spezielle Anlagenkomponenten wie Pumpen, Ventile oder Klappen Einfluss zu nehmen. Die intuitive Bedienung der FIS# Oberfläche spielt hierbei eine wichtige Rolle. Der Bediener muss keine speziellen Kenntnisse über die BACnet Funktionalität des priorisierten Objektbeschreibens [commandable Objects] besitzen. Mit einer globalen Schreibpriorität werden die Befehle direkt mittels ‚WriteProperty‘-Dienst an das Objekt übertragen. Damit der Zustand der benutzerspezifischen Übersteuerung visuell dargestellt werden kann, wird das entsprechende ‚Priority_Array‘ an der definierten Stelle abgefragt. Befindet sich ein Wert in diesem Arrayfeld (das Arrayfeld ist ungleich „NULL“), so wird eine Handmeldung am Symbol der Anlagenkomponente angezeigt. Alarmweiterleitung via E-Mail und SMS Eine weitere BACnet-Funktionalität wurde bei der Erfassung von Warnungen und Störungen genutzt: die Alarm- und Ereignisdienste. Anders als der bei vielen BACnet-Visualisierungen weit verbreitete quasi-Stan- 16 BACnet Europe Journal 12 04/10 Ansicht des fünf Sterne Hotels Kameha Grand Bonn. View of the Kameha Grand Bonn Hotel. dard der OPC-Kopplung, wird im FIS# nicht der Status einer einzelnen Eigenschaft (OPC-Item) eines Objekts abgebildet, sondern direkt Ereignisnachrichten empfangen. Damit Nachrichten automatisch verschickt werden, muss ein ‚NotificationClassObject‘ angelegt werden. Über dessen Klassenreferenzierung wird die Ereignisnachricht an die in der Objekteigenschaft ‚Recipient_List‘ eingetragenen Empfänger gesendet. Zur Alarmweiterleitung via SMS und E-Mail werden zusätzliche Nachrichtenobjekte benutzt. Ihnen kann der Bediener während der Laufzeit (ohne Neustart des Systems!) einzelne Meldungen zuordnen. Eine Anpassung Anwendungen Solutions FIS# Visualisierung einer Lüftungsanlage mit Energierückgewinnungssystem. FIS# visualisation of the ventilation system with energy recovery system. des Alarmtextes ist ebenfalls möglich, da hierzu auf die entsprechende Objekteigenschaft ‚Description‘ referenziert wird. Die Änderungen werden online im Flash der PCD3-Steuerung abgelegt und gesichert. Vernetzung von der Feldbis zur Managementebene Mit der Vernetzung der Feldüber die Automations- bis hin zur Managementebene realisierte die Hermos AG ein komplexes BACnet Projekt, das derzeit seines Gleichen auf dem Markt sucht. Technologische Neuerungen können dank BACnet, als offenes Kommunikationsprotokoll, auch in Zukunft nahtlos in das System integriert werden. The operator can take effect Supply of heating and cooling energy is performed by the energy center that is located in the basement of the ‘Bonner Bogen’. It pulls out energy from the ground water. Energy extraction is made by 3 pairs of suction and injection wells. Controlling the pumps and flaps of the well pairs is done by decentralised power-switch controls of type SAIA T760. The data from these controls is passed on to BACnet by a SAIA PCD3 controlling device that gets them via ProfiS-Net. From there the data is available to the management software FIS#. All data and control streams work the other way, too. By this, the Der Systemaufbau der TGA-Anlage im Hotel Bonn Visio. The system architecture of the hotel Bonn Visio. operator can take effect on the whole system by changing the setpoints as well as by specifying the desired settings on individual components like pumps, valves or flaps. All this can be done just by using the management software FIS#. An important issue in controlling the energy plant by FIS# is the good usability of the graphical user interface of the FIS# application. Operating it is very intuitive. The plant is modeled by symbols on which can be operated directly. No knowledge about BACnet and commandable objects is required by the operator. Applying a global write priority, the commands are sent directly to the respective object by the ‘WriteProperty’ service. Visualizing the user-specific override of an automatic control is done by reading from the respective ‘Priority_Array’ at the position that is defined for the respective control. If a value other than zero is found, a small hand ideogram is shown inside the symbol for the control, thus indicating manual override of the automatic control algorithm. Passing on alarms An additional feature of BACnet was used for managing warnings and alarms: the alarm and event services. In contrast to many other BACnet visualization implemen- tations which use the quasistandard OPC coupling for getting the current state of a particular object property (OPC item), FIS# receives event messages. For forwarding messages automatically, an object ‘NotifcationClass Object’ is provided by the software. When this object receives an incoming event message, it forwards it to the recipients that are registered in its ‘Recipient_List’ property. For passing on alarms via SMS and email, additional message objects are provided. The operator can assign specific messages to them at any time with immediate effect, that is, without restarting the system. Similarly, the operator can perform alarm text changes at any time with immediate effect. The alarm text is stored in the ‘Description’ property of the respective alarm object. All changes like this are stored as well in the flash memory of the PCD3 controlling system for making them permanent with regard to the next system start. Connecting flow from field level up to management level By connecting control and message flow from field level to automation level and up to the management level for a management system of a building and an energy plant, Hermos AG has realized a BACnet project of about the maximum complexity that is accomplished with BACnet in the current business market. Christian Kuhles Automatisierungssoftware HERMOS AG [email protected] www.hermos.com BACnet Europe Journal 12 04/10 17 ABB standard drives for HVAC – fluent in native BACnet – IP & MS/TP Frequenzumrichter für die Gebäudetechnik – beherrschen fließend BACnet – IP & MS/TP ABB standard drives for HVAC. 20 000 BACnet installations worldwide. HKL-Frequenzumrichter von ABB. 20 000 BACnet Installationen weltweit. Here’s why ABB standard drives for HVAC applications really Das sind die Gründe, warum HKL-Frequenzumrichter von ABB wirklich make a difference: den Unterschied machen: • Suitable for standard induction motors rated from 0,75 to • Für Standard-Asynchronmotoren mit einer Nennleistung von 355 kW (1 to 550 HP) 0,75 bis 355 kW (1 bis 550 HP) geeignet • Native BACnet embedded as standard • BACnet standardmäßig integriert • Direct connection to BACnet MS/TP networks – • Direkte Ankopplung an BACnet MS/TP-Netzwerke - kein Gateway no add-ons needed • Snap-on router as option - enables integration to BACnet/IP networks • BTL approved B-ASC (Application Specific Controller), conforms to ISO 16484-5:2007 Visit us at www.abb.com/drives notwendig • Aufsteckbarer Router ermöglicht Anbindung an BACnet/IP-Netzwerke • BTL-Zulassung B-ASC (Application Specific Controller), erfüllt ISO 16484-5:2007 Besuchen Sie uns im Internet unter www.abb.de/motors&drives E-Mail: [email protected] Anwendungen Solutions ASHRAE Geschäftsstelle spart mit BACnet Energie ASHRAE Adopts BACnet in Headquarters Building Kürzlich beschloss ASHRAE, ihre Hauptgeschäftsstelle mit besonderem Augenmerk auf Nachhaltigkeit komplett zu renovieren. Ziel war die Erlangung der LEED-EB und LEED-NC Gold-Bewertung des US Green Buildings Council. Recently ASHRAE decided to completely renovate their headquarters building with sustainability as a central theme. They set a goal of earning LEED-EB and LEED-NC Gold ratings from the US Green Buildings Council. ASHRAE wollte ein innovatives Modellprojekt schaffen, das heißt, es sollten Geräte diverser Hersteller verwendet werden. Dabei muss die Bedienoberfläche sehr intuitiv mit den einzelnen Geräten verbunden werden, um die maximal mögliche Effizienz der übergeordneten Regelung zu erreichen. Diese Vorgaben machten BACnet zur logischen Wahl für das Gebäudeautomationssystem, da es von Anfang an dafür geschaffen wurde, ein gemeinsames Protokoll für die Gebäudeautomation anzubieten. In diesem Projekt integrierte BACnet Informationen von 23 großen Gerätegruppen und sieben verschiedenen Herstellern in ein Benutzer-Interface. Dieses Interface bietet eine Grafik mit 1.800 Datenpunkten, zusätzlichen Datenwerten über Trends, Zeitpläne, Konfigurationseigenschaften und Detailbildern an. Ein konzeptionelles Netzwerkdiagramm dieses Systems ist auf der Abbildung zu sehen. Sie zeigt, dass die Regler, die die allgemeinen Gebäudebedingungen überwachen, mit einem BACnet / I P Backbone verbunden sind. Zusätzlich ist ein System zur Überwachung der Luftqualität in den Innenräumen vorhanden. Perfektes Zusammenspiel der Komponenten Der erste Stock des Gebäudes wird durch Multisplit-Geräte mit variablem Kältemittelstrom sowohl geheizt als auch gekühlt. Die Frischluftzufuhr wird durch ein Lüftungsgerät eines anderen Herstellers übernommen, welches Luft an VAV-Boxen leitet, die wiederum durch Regler eines dritten Herstellers bedient werden. Die durch BACnet ausgeführte Einbindung von Zeitplänen, Übersteuerungsmöglichkeiten, Sensormesswerten und anderen Schlüsseldaten ist essentiell zur Gewährleistung eines perfekten Zusammenspiels dieser Komponente. Die Beleuchtung wird durch BACnet-geregelte Leistungs- schalter, die mit dem IPNetzwerk verbunden sind, gesteuert. Bereiche, die sich in der Nähe der Außenwände befinden, sind mit Fotozellen ausgestattet, die die künstliche Beleuchtung automatisch zurückfahren, wenn natürliches Licht vorhanden ist. Die Belüftung der VRF-Bereiche und die Wasser-Wär mepumpen nutzen BACnetController über den ARCNET-Feldbus. Dieser ist durch einen BACnet Router mit dem Haupt-IP-Backbone verbunden. Da die Netzwerke auf beiden Seiten des Routers von BACnet sind, ist der Transfer komplexer Daten wie Alarme, Zeitpläne und Trends problemlos möglich. Der Router transferiert die BACnetNachrichten von einem Medium zum anderen. Theorie versus Praxis Bisher wurde beschrieben, wie alles in der Theorie funktionieren sollte, aber wie hat es in der Praxis funktioniert? „Für den Nutzer stellt es sich wie ein großes System dar“, sagt Michael Vaughn, ASHRAE’s Manager für Forschung und Technischen Service. „Mit nur einem oder zwei Mausklicks kann ich zwischen der Gebäudewetterstation, Stromverbrauchswerten und Zonensollwerten navigieren. Eine weitere Verbesserung ist die Möglichkeit, mit wenigen Klicks Punkte aus der Vielzahl von Systemen auszuwählen.” Geschätzt wird der Energieverbrauch des Gebäudes 30 % niedriger als der Durchschnittsverbrauch 2007 sein. Dennoch gibt es noch weitere Einsparpotenziale. „Wir nehmen immer noch Systeme in Betrieb und optimieren andere” sagte Michael Vaughn. „Die GLT war sehr hilfreich bei der Identifizierung von Bereichen, die wir uns noch einmal genau ansehen müssen oder in denen noch Verbesserungspotenzial steckt.” Dadurch ist es möglich, ursprüngliche Ziele für das Gebäude, welches kürzlich die LEED-NC Platin-Bewertung erhielt, noch zu übertreffen. BACnet Europe Journal 12 04/10 19 Anwendungen Solutions Die Regler zur Überwachung der Gebäude bedingungen sind über ein BACnet / IP Backbone verbunden. The controllers are connected to a BACnet / IP backbone. ASHRAE wanted to make this a showcase for innovation, which meant there would be multiple vendors’ equipment used in the project. The operation of this equipment had to be closely integrated to maximize the overall building performance. This made BACnet the logical choice for the building automation system, as it was designed from the ground up to provide a common protocol for building automation. In this project, BACnet integrated information from 23 major types of equipment made by 7 different manufacturers into a single user interface. This interface presented 1800 I / O points on the graphics, with countless additional data values available through trends, schedules, configuration properties, and other detail screens. A conceptual network diagram of the system is shown in Figure 1. air quality monitoring system on this network. Figure 1 shows that controllers which monitor the overall building conditions are connected to a BACnet / I P backbone. There is also an indoor Ventilation for the VRF zones on the first floor and the water source heat pumps (WSHP) on the second floor use BACnet controllers via Operating unison Primary heating and cooling on the first floor of the building are provided by variable refrigerant flow (VRF) fan coil units. Ventilation is provided by a Dedicated Outdoor Air Supply (DOAS) unit from a different vendor which supplies air to VAV boxes controlled by a third vendor. BACnet integration of schedules, overrides, sensor readings, and other key data is essential to keep these units operating in unison. Lighting control is provided by BACnet controlled circuit breakers connected to the IP network. Zones near outside walls contain photocells which automatically scale back the artificial lighting when natural lighting is available 20 BACnet Europe Journal 12 04/10 an ARCNET field bus. This is connected to the main IP backbone by a BACnet router. Since the networks on both sides of this router are BACnet, complex data like alarms, schedules and trends pass freely through the router. The router simply transfers the BACnet messages from one medium to another. Theory versus practice The preceding paragraphs described how everything should connect in theory. How did it work in the real world? “It appears to the user to be one large system,” said Michael Vaughn, ASHRAE’s manager of Research and Technical Services. “It allows me to easily navigate between the building’s weather station, sub-metered power panels, and zone set-points with just a click or two of the mouse. The ability to trend and view points from a variety of systems with just a few clicks is another big improvement.” Michael estimates the building’s energy use is about 30 % below the baseline consumption in 2007, but there is still room for improvement. “We are still commissioning some systems and optimizing others”, he said. “The BAS has been very useful in this effort by helping to identify areas that require additional attention or could be improved.” This is helping them to exceed their initial goals for the building, which recently earned a LEED-NC platinum rating. Steve Tom, Ph.D., P.E., Director of Technical Information, Automated Logic Corporation www.automatedlogic.com Anwendungen Solutions Energiesparkurs in Hotels Hotels on Course to Save Energy Hotelgäste erwarten komfortable klimatisierte Zimmer. Kostendruck und Verantwortungsbewusstsein gegenüber der Umwelt forcieren Maßnahmen zur Energieeinsparung. Für die herkömmliche Klimatechnik sind das gegensätzliche Anforderungen. Doch gerade bei der Hotelklimatisierung ergeben sich durch die typisch stark schwankende Hotelauslastung enorme Energieeinsparpotentiale ohne Komfortverlust, wenn es gelingt, die Klimatisierung an die Zimmerbelegung zu binden. Hotel guests expect comfortably conditioned rooms. Cost pressure and environmental awareness force energysaving measures. For conventional HVAC systems these are contradictory requirements. However, the usually significantly fluctuating occupancy rate of hotels provides an enormous energy-saving potential without any loss of comfort – if you succeed in linking climate control with room occupancy. Genau dies erfüllen ICSController mit FidelioSchnittstelle. Fidelio ist eine deutschlandweit sowie auch international führende Hotelbuchungssoftware. Über die Fidelio-Schnittstelle können Raumbelegungsinformationen aufgenommen und für die Klimaregelung verwendet werden. ICSController (InlineControlServer) sind grafisch programmierbar und können über steckbare I / O -Klemmen selbst als Klimaregler arbeiten oder die Raumbeleuchtung per DALI steuern. Zusätzlich verfügen die Steuerungen über standardisierte Schnittstellen der Gebäudeautomation, über die die Belegungsinformationen anderen Regelgeräten verfügbar gemacht werden können: BACnet® / I P Die ICS-Steuerungen mit BACnet-Schnittstelle erfüllen die Funktionen eines BACnet advanced application controllers (B-AAC) und enthalten darüber hinaus Client-Funktionen zum Objektzugriff. Somit können die Fidelio-Informationen wahlfrei über eigene Serverobjekte bereitgestellt oder auf BACnet-Objekte anderer BACnet-Geräte geschrieben werden. LONMARK® TP / F T-10 LONMARK® IP-852 Darüber hinaus können Controller der ICS-Familie die Belegungszustände von Hotelzimmern auch über Webservices und E-Mail verbreiten, mit Zeitsteuerfunktionen verknüpfen oder protokollieren. So werden belegte Zimmer im Komfort-Modus und unbelegte Zimmer im energiesparenden Standby-Modus betrieben. Da die Belegung des Zimmers erst mit dem Einchecken des Gastes erkannt wird und nur wenig Zeit bis zum Betreten des Zimmers bleibt, wäre der Betrieb unbelegter Zimmer im noch energiesparenderen Economy-Modus (s. Bild) mit Komforteinbußen ver- Energiebedarf / Energy demand Comfort Standby Sollwertverlauf für Klimaregelung / Setpoint chart for climate control Economy konventionell / conventional bei Zimmerbelegungsauswertung / considering room occupation bei Zimmerbelegungsauswertung inkl. Pre-Check-In-Funktion / considering room occupation incl. Pre-Check-In function PreCheck-In Check-In Check-Out sysmik©2010 Sollwertverlauf der Klimaregelung. Setpoint chart for climate control. bunden, was im Hotelgewerbe inakzeptabel ist. Nicht belegte Zimmer werden im EconomyModus betrieben Micros® Fidelio Suite 8 (ab Version 8.7) unterstützt die neue „Pre-Check-In“-Funktion bzw. den „Energy Management System Scheduler“: Eine einstellbare Zeit vor dem erwarteten Eintreffen eines Gastes generiert diese Funktion eine Information, die ebenfalls von den BACnet Europe Journal 12 04/10 21 Anwendungen Solutions SysMik-BACnet-Controller und Fidelio-Hotelbuchungssoftware im neuen Messehotel Essen. SysMik-BACnet controller and Fidelio hotel booking software in the new Messehotel Essen. ICS-Controllern ausgewertet werden kann. Nicht belegte Räume können so im Economy-Modus betrieben und ausreichend lange vor Eintreffen des Gastes in den Standby-Modus versetzt werden, um bei Betreten des Raumes durch den Gast angenehm temperiert zu sein. ICS als universelles Gateway Für reine Gatewayanwendungen stellt SysMik® verschiedene Festapplikationen zur Verfügung, die per Webbrowser konfiguriert werden und Raumbelegungsinformationen (strukturiert nach Zimmernummern) an verschiedenen Kommunikationsschnittstellen zur Weiterverarbeitung verfügbar machen – ganz ohne Programmieraufwand. Projektspezifische Anpassungen können auf Anfrage realisiert werden (z.B. Aufheizoptimierung oder Sommerkompensation). Exactly this is achieved by ICS controller types with a Fidelio interface. Fidelio is a leading German and international hotel booking software. Via a Fidelio interface, room occupancy information can be acquired and used for climate control. ICS controllers (InlineControlServer) are graphically programmable and can act as climate controllers or DALI lighting controllers using pluggable I / O terminals. Furthermore, the controllers have standardized building automation communication interfaces that provide occupancy data for other control devices: BACnet ® / I P ICS controllers with BACnet interface conform to BACnet advanced application controllers (B AAC) and moreover contain client functions for object access. Therefore the Fidelio information can be provided via its own server objects or can be written to BACnet objects of foreign BACnet devices. LONMARK® TP / F T-10 LONMARK® IP-852 Controllers of the ICS family can also publish occupancy 22 BACnet Europe Journal 12 04/10 information signals by web services and email, combine them with scheduling information and log them. This way all occupied rooms operate in comfort mode while unoccupied rooms stay at energy-saving standby mode. As the occupancy of a room is detected just when a guest checks in, there is only little time remaining until he enters the room. Therefore the operation of unoccupied rooms in the even more energy-saving economy mode (see figure) is not feasible without a loss of comfort – which is unacceptable in the hotel business. What is new? Micros® Fidelio Suite 8 (from version 8.7) supports a new “Pre-Check-In” function also called an “Energy Management System Scheduler”: a configurable time interval prior to the expected arrival time of a guest, this function generates information that is interpretable by the ICS controllers. Unoccupied rooms can be operated in economy mode. With precheck-in information there is enough time for climate control to ensure a comfortable temperature when the guest enters his room. ICS for universal gateway For pure gateway applications SysMik® provides several ready-to-use applications that can be parameterized via web browser and which provide room occupancy information (structured by room numbers) via different communication interfaces for further processing with no programming effort. Specific adaptions can be realized on request (e.g. heat-up optimization or summer compensation). Gerd Schnitzlein SysMik GmbH [email protected] www.sysmik.de Hotel Atlantis, the Palm in Dubai. DESIGO Gebäudemanagement für ein exotisches Golfparadies Atlantis – With DESIGO Building Automation and Control System Atlantis, The Palm, ist eine Inselanlage mit 1.539 Zimmern im Zentrum der halbmondförmigen, künstlichen Palm Jumeirah in Dubai. Für das Royal Tower Hotel, das Konferenzzentrum, die Einzelhandelsgeschäfte und den Wasserpark bietet das DESIGO Gebäudeautomations system (GA-System) eine umfassende und durchgängige Kontrolle und Steuerung. Atlantis, The Palm, is a 1,539 room, ocean-themed destination resort located at the centre of the crescent of the manmade Palm Jumeirah in Dubai. The DESIGO building automation and control system (BACS) employed by the Atlantis project covers the following areas: Royal Tower Hotel, the conference center, the retail village, and the water park. Das DESIGO-GA-System des Komplexes umfasst über 120 DESIGO PX-BACnet DDCRegler mit 22.000 Datenpunkten, einschließlich Inte- gration von Drittsystemen. Alle DESIGO PX-BACnet DDC-Regler sind direkt mit der bestehenden IT-Infrastruktur verbunden. Da die Systeminformationen im Gebäude-LAN für die Managementstationen verfügbar sind, bietet es dem Kunden mehr Flexibilität, wenn es darum geht, auf alle Informationen von einem beliebigen Ort aus zuzugreifen. Ebenso erleichtert dies die Fehlersuche. Einige signifikante Features Bei Atlantis wird die Raumtemperatur in allen Gästezimmern über Umluftgeräte geregelt. Insgesamt sind in den Zimmern 1.705 Umluftgeräte installiert. Das HotelManagementsystem (Opera) ist über eine Schnittstelle mit dem GA-System verbunden. Trifft ein Gast ein und bekommt vom Front Office sein Zimmer zugeteilt, erhält das GA-System die Information, dass der Zimmerstatus auf „Occupied” geändert wurde. Daraufhin erhöht das GA-System bis zum Eintreffen des Gastes in seinem Zimmer automatisch den Raumtemperatur-Sollwert auf “Comfort”. Wenn der BACnet Europe Journal 12 04/10 23 Anwendungen Solutions Gast seinen Hotelaufenthalt beendet, wird der Raumtemperatur-Sollwert wieder auf „Economy” reduziert. Dies bringt beachtliche Energieeinsparungen. Alle kritischen Alarme werden vom GA-System als SMS an die verantwortlichen Instanzen im Hotel übermittelt. Hierdurch wird es dem Unterhaltsteam ermöglicht, schnell Maßnahmen zu ergreifen. Merkmale der DESIGOManagementstation Das integrierte Offline- und Online-Trending kann für die bequeme Analyse von Echtzeitdaten (online) und historischen Daten (offline) basierend auf BACnet TrendLog-Objekten genutzt werden. Der Zugriff auf die Managementstation und somit auf das gesamte GA-System, ist nur autorisierten Benutzern gestattet. Sobald die Zugangsdaten eingegeben werden, prüft das System die dazugehörigen Zugriffsprivilegien und gewährt lediglich Zugriff auf die befugten Anlagen und Applikationen. Hauptaufgabe der Managementstation ist es, einen strukturierten Überblick und übersichtliche Bedienung der Anlagen zu gewährleisten. Im Zusammenhang mit der Behandlung von Alarmen ist dies besonders wichtig und eine der Stärken des GASystems. Die Alarme werden automatisch registriert, durch die Managementstationen aufgezeichnet, weitergeleitet und wenn nötig ausgedruckt. Unterstützt werden sowohl BACnet Intrinsic Reporting als auch BACnet Algorithmic Reporting. Um den Benutzer schnell auf eine Alarmsituation aufmerksam zu machen, werden alle Alarme mit entsprechend hoher BACnet-Alarmpriorität in Popup-Fenstern angezeigt. Diese Alarmnachrichten erscheinen selbst dann im Vordergrund, wenn der Benutzer gerade in einem an- deren Windows-Programm arbeitet. Der Benutzer kann den Alarm im Popup-Fenster quittieren oder direkt zum dazugehörigen Anlagenschema wechseln, um detailliertere Informationen zu erhalten oder das Problem zu analysieren. Der Log Viewer zeigt Ereignisse und Benutzeraktivitäten an, die in chronologischer Reihenfolge in einer Datenbank registriert sind. Eine Aufzeichnung aller vergangener Aktivitäten und Ereignisse ist somit gewährleistet. Dies erlaubt es dem Benutzer auf einen Blick zu sehen, welche Ereignisse während seiner Abwesenheiten geschehen sind. Der Log Viewer bietet zudem ein klares Bild über die Aktivitäten und Ereignisse, wenn mehrere Benutzer am gleichen System arbeiten. The DESIGO BACS installed at Atlantis comprises over 120 DESIGO PX BACnet DDC controllers with 22,000 data points, including integration with thirdparty systems. All DESIGO PX BACnet DDC controllers are directly connected to the existing building IT infrastructure. As the system information for the management stations is available over the building LAN, the customer has more flexibility to access all information from anywhere in the network, and this also helps with troubleshooting. Some significant features All guest rooms at Atlantis are controlled via fan coil units. Altogether there are 1,705 fan coil units in the guest rooms. The hotel management system (Opera) is interfaced with the DESIGO BACS. When the front office checks a guest in to a particular room, the information is available to the BACS that the room status has been changed to “Occupied”. Then, the BACS automatically raises the room temperature setpoint to “Comfort” by the time the guest actual- 24 BACnet Europe Journal 12 04/10 Einweihungsfeier des Atlantis auf der halbmondförmigen, künstlichen Palm Jumeirah in Dubai. Opening ceremony of the Atlantis, located at the centre of the crescent of the manmade Palm Jumeirah. ly arrives in the room. When the guest checks out, the room temperature setpoint is reduced to “Economy”. printer if needed. Both BACnet intrinsic reporting and BACnet algorithmic reporting are supported. All critical alarms are sent as SMS from the BACS to the identified group of hotel operators. This enables the maintenance team to take quick action. To alert the user quickly to an alarm situation, all alarms of sufficiently high BACnet alarm priority are displayed in popup windows. The alarm messages are even displayed in the foreground when the user is working in another Windows program. The user can acknowledge the alarm in the popup window, or jump directly to the associated plant diagram for more detailed information and analysis of the problem. DESIGO management station features The fully-integrated offline and online trending can be used for convenient analysis of both real-time data (online) and historical data (offline) based on BACnet TrendLog objects. Access to the management station and therefore to the entire system is granted only to authorized users. When a user enters a user name and password, the system verifies the associated access privileges and grants access only to the relevant plant and applications. The main purpose of the management station is to ensure a structured overview and clear operation of the plants. In the context of alarm handling, this is particularly important and one of the strengths of the overall BACS. Alarms are automatically registered and logged – via the management stations, transmitted and routed to the The Log Viewer displays events and user activities logged in chronological order in a database, providing a record of all past activities and events. This enables operators to see what has happened in their absence at a glance. It also provides a clear picture over events and useractivities in cases where several users are working on the same system. Klaus Wächter Siemens Switzerland Ltd [email protected] www.siemens.com / buildingtechnologies Anwendungen Solutions Innovative Klimatisierung im Forschungsprojekt inHaus2, Duisburg Innovative Air Conditioning in the inHaus2 Research Program, Duisburg Neuartige Technologie zur Luftentfeuchtung mit regenerativen Energien und hybriden Kompakt-Kaltwassererzeugern verdeutlichen es – Ressourcenschonender Einsatz von Energie ist möglich mit der Klimatisierung der Menerga GmbH und einer Gebäude automation der SE-Elektronic GmbH. Innovative new technology for air dehumidification with renewable energies and hybrid compact cold water generators make it clear that resource-saving energy consumption can be achieved with air conditioning from Menerga GmbH and building automation from SE-Elektronic GmbH. Die Forschungsanlage inHaus2 der Fraunhofer Gesellschaft in Duisburg wurde mit der neuartigen Technologie der sorptionsgestützten Klimatisierung des SE-Electronik Partners der Menerga GmbH ausgerüstet. Es handelt sich dabei um einen Sorptionsprozess zur Entfeuchtung. Dabei wird Luft an der Oberfläche eines Rieselfilms aus konzentrierter Salzlösung getrocknet. Die Regeneration der Salzlösung erfolgt durch Austreiben des Wassers über Erwärmung. Hierzu sind Temperaturen von 55 bis 70 °C ausreichend, so dass regenerative Wär- mequellen wie Solarthermie in Betracht kommen. Beim inHaus2 wird hierfür Fernwärme verwendet. Mit der sorptionsgestützten Klimatisierung ist eine deutliche Steigerung der Energieeffizienz bei Klimageräten möglich, was bereits von der Fraunhofer Gesellschaft im Rahmen eines mehrere Jahre dauernden Forschungsprojektes nachgewiesen wurde. Sorptionsgestützte Klimatisierung hat sich bewährt Mit den Pilotanlagen des Mülheimer Unternehmens hat sich die sorptionsgestützte Klimatisierung in Deutschland und Europa zum ersten Mal mit nennenswerten Betriebserfahrungen bewährt, die durch umfangreiche Messtechnik und Messwerterfassungssys teme belegt wurden. Forschungsanlage inHaus2 der Fraunhofer Gesellschaft in Duisburg. The inHaus2 research facility at the “Fraunhofer Gesellschaft” in Duisburg. Regelung und Steuerung über BACnet Zur Kühlung der Luft kommen verschiedene Techniken zum Einsatz: Die Grundlast wird über Geothermie abgeführt, die im Verbund mit einem hybriden Kompakt-Kaltwassererzeuger von Menerga be- BACnet Europe Journal 12 04/10 25 Anwendungen Solutions BACnet Building Controller E-DDC3.1 von SE-Elektronic. The E-DDC3.1 BACnet building controller from SE-Elektronic. trieben wird, welcher bei steigendem Kühlbedarf zuschaltet. In diesem Gerät sind drei Verfahren zur Kälteerzeugung realisiert und kaskadenförmig verschaltet. Bei geringen Außentemperaturen erfolgt die Kaltwassererzeugung über freie Kühlung. Bei steigenden Außentemperaturen kommt die „adiabate“ Verdunstungskühlung zum Einsatz und erst bei sehr hohen Außentemperaturen wird zusätzliche Kälte über einen Prozess mit Kompressor erzeugt. Die Regelung und Steuerung der energieeffizienten Verfahren erfolgt durch eine Gebäudeleittechnik der SE-Elektronic GmbH aus Göppingen. Die SE-Elektronic GmbH bietet eine BACnet Kommunikation sowohl für Kleinregler (wie Sensoren) als auch für Großregler (wie Automationsstationen). Menerga GmbH als Hersteller von Klimageräten und SE-Elektronic GmbH als Hersteller von Steuer- und Regelungstechnik in der Gebäudeautomation sorgen für optimierte, energieeffiziente Lösungen in der Gebäudeklimatisierung. The inHaus2 research facility at the Fraunhofer Gesellschaft in Duisburg has been equipped with the new and novel sorption-based air conditioning technology provided by our partner Menerga GmbH. Here, a sorption process takes care of the dehumidification whereby the air is dried on a trickling film surface that is made up of concentrated brine. The regeneration of the brine is achieved by the water being expelled as a result of a rise in temperature. Temperatures of between 55 and 70 °C are sufficient for this purpose, which means that regenerative heat sources such as solar thermal energy can be considered. District heating is used in inHaus2. A substantial increase in energy efficiency can be achieved with the use of sorptionbased air conditioning – something that the Fraunhofer Gesellschaft proved within the framework of a research project lasting several years. Sorption-based air conditioning With the pilot plants from the Mülheim-based company, the sorption-based air conditioning was able to 26 BACnet Europe Journal 12 04/10 prove its worth in Germany and Europe for the first time thanks to significant operating experiences that were underlined with comprehensive measurement technology and measurement acquisition systems. Control of the energyefficient process by BACnet Diverse techniques are used in order to cool the air: The base load is discharged using geothermal energy that is operated together with a hybrid compact cold water generator produced by the Mülheim-based air conditioning manufacturer. It switches on as soon as an increase in the cooling requirement is detected. Three procedures for refrigeration are implemented in this device and are connected in a cascade formation. In the event of low external temperatures, the cold water is created by means of free cooling. In the event of increasing external temperatures, “adiabatic” evaporative cooling is used. Additional cooling is created by means of a compressor only in the event of extremely high external temperatures. The control of the energy-efficient process is taken care of by a building control system manufactured by SE-Elektronic GmbH based in Göppingen. SE-Elektronic GmbH provides you with a BACnet communication for both small regulators (such as sensors) as well as large regulators (such as automation stations). SE-Elektronic GmbH and Menerga GmbH Menerga GmbH, manufacturers of air conditioning units, and SE-Elektronic GmbH, manufacturers of control technology in the field of building automation, provide optimised and energyefficient solutions in the field of building climate control systems. Bogomir Dajcman Geschäftsführer SE-Elektronic GmbH [email protected] www.se-elektronic.de Dr. Jürgen Röben Geschäftsführer Menerga GmbH [email protected] www.menerga.com Anwendungen Solutions Da steckt Energie drin: Green-IT Energy optimization with Green-IT Energie sparen und optimieren kann nur ein System, das seine Verbraucher kennt, diese kontinuierlich beobachtet und sensibel auf Veränderungen reagiert. Die AirITSystems ist verantwortlich für den kommunikations- und informationstechnischen Betrieb am Hannover Airport. In diesem Zusammenhang betreibt das Unternehmen u.a. die Gebäudeleittechnik und die Rechenzentren. AirITSystems hat am Hannover Airport das zukunftsweisende Projekt „Green-IT“ ins Leben gerufen und damit neue Maßstäbe in Sachen verantwortungsvollen Umgang mit Energie in Großrechenzentren gesetzt. Es geht dabei in erster Linie um die nachhaltige Senkung des Energieverbrauchs. No system can save and optimize energy unless it knows its own users, monitors them continuously and responds sensibly to any changes. AirITSystems is the company responsible for running communications and IT at Hanover Airport, within which context it also operates building management and data centres. At Hanover Airport, the company AirITSystems has developed the progressive Green-IT project, which sets new benchmarks in responsible energy behaviour within large data centres. Its primary concern is the sustainable reduction of energy consumption. Das zukunftweisende Projekt „Green-IT“ am Hannover Airport. The progressive Green-IT project at the Hanover Airport. 28 BACnet Europe Journal 12 04 / 10 Dieser Ansatz beginnt mit der Leistungsreduzierung im Standby-Betrieb und setzt sich fort mit der Entwicklung energiesparender Hardund Softwarekomponenten bis hin zur energiesparenden Virtualisierung. Auch im Dienstleistungsbereich wird sich der Effekt von Green-IT nützlich erweisen und zwar durch das Argument der CO2-Einsparungen. Webinare, Webcasts oder Webkonferenzen sind entsprechende Dienstleistungsangebote, die durch das Label Green-IT für ih- re Kohlendioxideinsparung stehen. Das Rechenzentrum bietet heute ausreichend Rechenleistung für ca. 700 Clients. Dazu gehören 19 ServerRacks mit 160 Serversystemen und 60TB EVA, EMSA Massenspeicher incl. Spiegelung. Der Betrieb wird durch 2 USV Anlagen mit je 30 und 40 KW Stromversorgungsredundanzen sichergestellt. 90 Energiemessstellen sorgen dafür, dass der Energiekonsum stets unter Kontrolle bleibt. Um den hohen Ansprüchen zu genügen wurden Anwendungen Solutions für das Energie-Management-System ausschließlich Komponenten in industrieller Qualität gewählt. Zur Energiemessung vor Ort kamen busfähige MID-geprüfte Energiezähler von SaiaBurgess zum Einsatz, die mit einer SaiaPCD3.M3120 vernetzt wurden. Die so gewonnenen Daten werden direkt in der SPS verarbeitet, archiviert und über BACnet an den Leitstand, bestehend aus der Gebäudeleittechnik Software IBS8, zur Überwachung und Monitoring übermittelt. Was bedeutet Green-IT? Zu den Zielen gehören neben der Zertifizierung des Rechenzentrums u. a. nach erfolgreicher Energieoptimierung auch handfeste wirtschaftliche Vorteile. Der vorgefundene technische Stand entspricht der Situation in vielen Unternehmen mit „gewachsenen IT-Strukturen“. Für ein „Green-IT-Zertifikat“ sind jedoch einige Optimierungsaufgaben zu erfüllen. Green-IT sieht daher eine schrittweise Implementierung vor. Im ersten Schritt ist der Aufbau eines AirITEnergieerfassungssyst ems für das Rechenzentrum realisiert worden. Dazu gehört das Monitoring zum Auffinden von „Stromfressern“, Lastspitzen und deren Bedingungen. Im zweiten Schritt werden aus den gewonnenen Erkenntnissen gezielte Investitionen zur Erreichung von Quick-Wins umgesetzt wie u.a. dem Einsatz von virtuellen Servern, Thin Provisioning, Abschalten nicht genutzter Ports und freier Kühlung. Fairer Wettbewerb Der Einsatz von BACnet garantiert dem Flughafen Systemoffenheit und über fabrikatsneutrale Ausschreibungen einen fairen Wettbewerb. Dank BACnet kann ein identisches Bedienkonzept und eine gleiche visuelle Darstellung aller vernetzten Anlagen für alle Hersteller gewährleistet werden. Darüber hinaus ist BACnet zur weiterführenden Nutzung geeignet z.B. Türzugangskontrollen, Brandmeldeanlagen, Sprechanlagensteuerungen, Energiemanagement, Notlichtund anlagenüberwachung Wartungsmanagement. This approach starts with power reduction during stand-by operation and proceeds through the development of energy-saving hardware and software components to arrive at energy-saving virtualization. The effect of Green-IT will also prove useful in the service area, due specifically to the argument that it saves CO2. Webinars, webcasts and web conferences are appropriate services offered under the Green-IT label because they stand for carbon dioxide savings. Today, the data centre offers sufficient computing power for approx. 700 clients comprising 19 server racks with 160 server systems and 60TB EVA, EMSA mass memory, mirroring included. Operation is guaranteed with 2 USV systems, each having Green-IT: Das Rechenzentrum am Hannover Airport. The data center at Hanover Airport: Green-IT. 30 and 40 KW power supply redundancy. 90 energy testing points ensure that power consumption always remains under control. To satisfy high demands, only industrial quality components have been selected for the energy management system. For on-site energy measurement, bus-compatible, MIDapproved energy meters from Saia-Burgess were used and networked with a SaiaPCD3. M3120. These energy data are processed directly in the PLC, archived, and forwarded to the management system via BACnet. The control station comprises IBS8 building management software for supervision and monitoring. What does Green-IT mean? The aims of Green-IT include not only data centre certification after successful energy optimization, but also tangible, economic advantages. The technical status encountered corresponds to the situation in many companies with fully developed IT structures. For a Green-IT certificate, however, some optimization work needs to be done. Green-IT therefore provides for step-by-step implementation. The first step was to set up an AirIT energy logging system for the data centre. This includes moni- toring to identify ‘power eaters’, peak loads and their conditions. The second step is then to implement concrete measures using the findings obtained like changing old server systems for virtual servers, thin provisioning, switching off unused ports and free cooling. Vendor-neutral tendering The use of BACnet guarantees system openness for the airport and therefore fair competition via vendorneutral tendering. Thanks to BACnet, it is possible to guarantee an identical control concept and the same visual representation for all networked systems from all manufacturers. Moreover, BACnet is also suitable for further uses, e.g. door access control, fire alarm systems, intercom controllers, energy management, monitoring of emergency lighting systems and service management. Oliver Greune Saia-Burgess Controls AG [email protected] www.saia-pcd.com Marc Blanke Technische Anlagen AirITSystems GmbH [email protected] www airitsystems.de BACnet Europe Journal 12 04/10 29 Anwendungen Solutions Mit Energieeffizienzmaßnahmen zu 91 Prozent Einsparung Smart Energy Efficiency Measures Lead to 91 Percent Cost Reduction Mit dem Neubau eines Produktionswerkes beschreitet ebmpapst Mulfingen, der Spezialist für Motoren und Ventilatoren, bei der Nutzung von Prozessabwärme neue Wege und leistet damit Pionierarbeit. Energieeffizienz hat bei ebmpapst sowohl für die eigenen Produkte als auch für die Gebäude einen hohen Stellenwert. Von Anfang an wurde dies dem Architekten und Ingenieurbüro als Hauptziel mit auf den Weg gegeben und hat zu intelligenten und höchst energieeffizienten Lösungen geführt. With the new construction of the production plant of ebmpapst Mulfingen, the specialist in motors and ventilators breaks new ground in the utilization of process heat. Energy efficiency has high priority for ebmpapst, both for their own products as well as for their buildings. Right from the start of this project this main aim was pointed out to the architect and the engineering office, which led to intelligent and highly energy-efficient solutions. In Mulfingen-Hollenbach realisierte man ein Konzept, das vorsieht nahezu den gesamten Wärmebedarf des Gebäudes über vorhandene Wärmelasten zu decken. Anhand einer Gebäude- und Anlagensimulation wurde die optimale Lösung für die Auswahl der haustechnischen Anlagen erarbeitet. Schon in der Planungsphase betrachtete man daher die Gebäudeteile Lager, Büro und Produktion als Gesamtkomplex und zog die überschüssige Wärme aus der Produktion zur Beheizung des Lagers und der Büro räume heran. Die Beheizung der Lagerbereiche (Wareneinund Ausgang) erfolgt durch die Abwärme der Produktion (Dreherei und Montage). Die Abwärme der Druckluftkompressoren wird zur Ladung der beiden Pufferspeicher für die Heizung verwendet. Ein 1.100 m³ Sprinklerwasserbehälter dient als Wärmesenke im Sommer und Energiequel- Das neue Produktionswerk von ebmpapst in Hollenbach. The new production plant of ebmpapst located in Hollenbach. 30 BACnet Europe Journal 12 04/10 le im Winter. Wärmepumpen erhitzen das Wasser des Behälters im Sommer und entnehmen Wärme im Winter. Hinzu kommen Torluftschleier, Rückkühlwerke, freie Kühlung, Raumautomation, Heiz- und Kühldecken in den Bürobereichen und Ölkessel für die Spitzenlast. Bei der Auswahl der Komponenten und Systeme wurde ausschließlich auf modernste, energieeffiziente Technologien geachtet. Die Synergie eines intelligenten Anlagenkonzeptes und dem Einsatz von effizienten haustechnischen Anlagen führte so zu einer Einsparung von 91 % an Energiekosten für Heizung, Kühlung und Raumlufttechnik, verglichen mit dem Standard für EnEV-Neubauten. Anforderungen an die Gebäudeautomation Wegen des ganzheitlichen Konzeptes ist es von zentraler Bedeutung, dass die Informationsschwerpunkte eng miteinander verknüpft sind, um bedarfsgerecht die zugehörigen haustechnischen Anlagen zu regeln. Peer to Peer Kommunikation, freie Programmierbarkeit und hohe Verfügbarkeit waren für dieses innovative Bauprojekt Grundvoraussetzungen, die ein Automationssystem erfüllen muss. Zum Einsatz kam deshalb das System PMC2 der Fa. Neuberger. Das System erfüllt das erforderliche BACnet Geräteprofil B-BC, ist zertifiziert und bietet darüber hinaus HotplugFähigkeit zur Sicherstellung einer stetigen Produktion im Werk. Die offenen Schnittstellen von PMC2 ermöglichen eine flexible und unkomplizierte Integration von Wärmepumpen, Heizungskessel, Druckluftkompressoren und Rückkühlwerken. Visualisierung und Anlagenoptimierung Zur Bedienung und Visualisierung der Anlagen kam die Gebäudeleittechniksoftware ProGrafNT 6 von Neuberger zum Einsatz. Alle Daten aus den Automationsstationen werden über das BACnet / I P Netzwerk übertragen und auf der GLT visualisiert. Die ProGrafNT mit flexibler, vollständiger historischer Datenbank ermöglicht es, Archivcharts frei und beliebig kombinieren zu können. Der Anwender erkennt so sehr schnell die anlagentechnischen Zusammenhänge und kann effektiv und nachhaltig optimieren. Als nächstes ist geplant, durch Integration der 3-Tages-Wettervorhersage in die Gebäudeautomation weiteres Einsparpotenzial zu erschließen. Damit kann ProGrafNT schon im Voraus und automatisch entscheiden, ob Kälte- bzw. Wärmespeicher geladen werden, freie Nachtauskühlung notwendig ist und die richtige Energiequelle auswählen. Anwendungen Solutions Systemarchitektur der Gebäudeautomation im Werk Hollenbach. The building automation system architecture at Hollenbach. In Mulfingen-Hollenbach a concept has been realized which was designed to cover almost the entire heat requirement of the building by existing thermal loads. By means of a building and plant simulation it was possible to develop the ideal solution for the selection of the range of house automation plants. Already during the planning phase the different building parts such as the warehouse, office and production building were considered as a total building complex. Thus it is possible to use the excess heat from the production for heating of the warehouse and the offices. The warehouse area (incoming and outgoing goods) is heated by the waste heat from production (turning and assembly area). The waste heat of the air compressors is used to load the two buffer tanks for the heating. If no heat is required, a 1100m³ sprinkler reservoir is used as a heat sink in summer and an energy source in winter to take over the excess heat. The installed heat pumps heat the water of the reservoir in summer and take over heat in winter. Additionally, there are air curtains, recooling plants, free cooling, room automation, heating and cooling ceilings in the office areas and oil boilers for peak load. When choosing the components and systems, only state-of-the-art, energy-efficient technologies were considered. Synergy of an intelligent plant concept and the use of a highly efficient building automation system leads to energy savings of 91 % for heating, cooling, ventilation and air conditioning, compared with the standard according to the German Energy Saving Ordinance EnEV. Requirements on the building automation Due to the holistic concept, it is very important that the sets of controllers are closely connected with one another in order to regulate the associated building technology services as needed. Peer to Peer communication, free programmability and a high availability were the basic conditions to meet the requirements of this innovative project. For this reason the Neuberger PMC2 system was used. This system meets the required BACnet Device Profile B-BC, it is certified and furthermore, it offers hotplug capability to ensure a continuous production process in the factory. Furthermore, the open interfaces of PMC2 are of high importance to enable flexible and easy integration of heat pumps, boilers, air compressors and recooling plants. Visualization and plant optimization For operation and visualization of the plants the building management system software ProGrafNT 6, developed by Neuberger, was used. All available data from the automation stations are transmitted via BACnet / IP network and are visualized on BMS. On adjustment and optimization of the plants, the archiving of all information points in the building management system was a particulary decisive advantage. With the flexible, complete historical data base, ProGrafNT enables the user to combine archive charts freely and variably. So the user is able to understand the plant-specific coherences and can realize effective optimizations with sustained success. In the next step it is planned to integrate three-day weather forecast so that further energy savings are possible. Therefore ProGrafNT is able to automatically decide in advance, whether cold or heat accumulators are to be loaded, if free night time cooling down is necessary and can choose the right energy source. Jürgen Metzger Sales Management Neuberger Gebäudeautomation GmbH & Co. KG juergen.metzger@ neuberger.net www.neuberger.net BACnet Europe Journal 12 04/10 31 Anwendungen Solutions CO2-neutrale Wechselrichter-Fabrik setzt auf BACnet The World’s Largest CO2-neutral Inverter Factory Relies on BACnet Die SMA Solar Technology AG entwickelt, produziert und vertreibt als weltweiter Marktführer Solar-Wechselrichter und Überwachungssysteme für Photovoltaikanlagen. Als wichtigste Komponente und Herz einer Solarstromanlage wandeln SMA Solar-Wechselrichter den von Solar-Modulen erzeugten Gleichstrom in netzkonformen Wechselstrom um. Zudem sind sie als intelligente System-Manager auch für die Effizienz, Überwachung und das Netzmanagement verantwortlich. Die Unternehmensgruppe beschäftigt mehr als 4000 Mitarbeiter und erwirtschaftete in 2008 bei einem Umsatz von rund 680 Mio. Euro ein Ergebnis vor Zinsen und Steuern von über 165 Mio. Euro. SMA Solar Technology AG as world-wide market leader develops, produces and distributes solar inverters and control systems for photovoltaic systems. SMA solar inverters – the most important component and heart of a solar power system – convert the direct current generated in the solar modules into grid-compatible alternating current. Additionally they are also responsible as intelligent system managers for the yield monitoring and network management. The group employs more than 4,000 persons and in 2008 generated with a turnover of 680 million Euro, a return of more than 165 million Euro before interest and tax. Außenansicht der Wechselrichterfabrik SMA Solar Technology AG. Exterior view of the inverter factory – SMA Solar Technology AG. In nur 18 Monaten ist in Kassel eine CO2 neutrale Fabrik mit einer Spitzenkapazität von vier Gigawatt entstanden. Das Solar-Werk ist so groß wie zweieinhalb Fußballfelder und die gesamte Nutzfläche beträgt 26.000 m². Innerhalb der Produktionslinien der Leiterplattenbestückung werden pro Stunde 230.000 Bauteile verbaut, so dass ca. alle 30 Sekunden ein Wechselrichter das Werk verlässt. 32 BACnet Europe Journal 12 04/10 Das Energiekonzept Das Energiekonzept verknüpft die Energieträger Strom, Wärme, Kälte und Druckluft und nutzt vorhandene Synergien. Zur Strom erzeugung kommen eine PV-Anlage mit 1,1 MW Leistung sowie ein biogasbetriebenes BHKW zum Einsatz. Die Wärme wird von dem BHKW, einem Teil Fernwärme und der Abwärme der strombetriebenen Druckluftkompressoren erzeugt. Eine Absorptionskältemaschine nutzt die ständig zur Verfügung stehende Wärme des BHKWs. Zusätzlich kommt noch eine strombetriebene Kompressionskältemaschine bei zusätzlichem Kältebedarf zum Einsatz. Regelung und Managementsystem Als innovatives und zukunftsorientiertes Unternehmen setzte SMA für das neue Werk bezüglich der Gewerke HLK auf BACnet und für die Beleuchtung und Einzelraumregelung auf EIB. Zusätzlich sollen aus den Bestandsgebäuden noch 12 Unterstationen des Fabrikates Kieback&Peter integriert werden. Für Energieanalysen werden mittlerweile auch Energieverbräuche vom installierten FRAKO System integriert. Für das Managementsystem wurde eine herstellerübergreifende Lösung gesucht, mit der sich zum einen wirtschaftlich die Bestandsautomationsanlagen aufschalten lassen und die zum anderen zukünftig mit BACnet erweitert werden kann. Pro-BACnet migriert Derzeit sind 17 Unterstationen vom Typ HSC ProBACnet migriert. Die Datenpunktbasis wurde mittels der automatischen EDE-Importfunktion der IBS integriert. Feinanpassungen wurden dann mit Hilfe des integrierten BACnet Browsers vorgenommen. Anwendungen Solutions Die Technikzentrale mit BACnet Stationen. Technical centre with BACnet stations. Derzeit sind ca. 4.500 Datenpunkte auf der GLT IBSnetview visualisiert. Für den Betreiber bedeutet dies ein Höchstmaß an Bedienkomfort und Transparenz. Dadurch ist optimale Betriebsführung und somit ein wirtschaftlicher Betrieb erst möglich. Für ein aktives Energieverbrauchscontrolling ist derzeit das EIQ-Energiecontrollingprogramm der Firma INGA im Einsatz. Vollautomatisch werden die aktuellen Energiedaten der GLT in einer SQL Datenbank archiviert und können anschließend per beliebigem Webbrowser aufgerufen werden. Verbräuche, Kosten, Budgetkontrolle, CO2-Ausstoß, Berichte und Analysen lassen sich so schnell und einfach ermitteln und visualisieren. In only 18 months a CO2 neutral factory was built near Kassel with a peak capacity of four gigawatts. The solar factory occupies the area of 2.5 football fields and the total usable floor space is 26,000 m². Within the production lines of the PCB assembly 230,000 components are built- in per hour, so one can say that nearly every 30 seconds an inverter leaves the factory. The energy concept The energy concept combines the energy sources electricity, heat, cold and compressed air and uses already existing synergies. Electrical power is derived from a 1.1 MW photovoltaic system and an onsite biogas plant. The biogas plant satisfies a portion of the factory’s heating requirements, additional heat is pro- Darstellung des Energieverbundes auf der IBS-GLT. Presentation of the energy network on the IBS-GLT. vided by district heat and the waste heat of electrically operated air compressors. An absorption refrigeration uses the constantly available heat of the biogas plant (BHKW). In case additional cooling is needed, then a compression refrigerator is additionally used. Control and management system As an innovative and futureoriented company SMA relies on BACnet for the new plant with regard to HVAC applications, and on EIB for lighting and individual room control. Additionally 12 Kieback&Peter substations will be integrated from the already existing buildings. For energy analyses in the meantime also energy consumption data from the installed FRAKO System are also integrated. For the management system a manufacturer-spanning solution was searched for with which on the one hand the already existing automation systems can be economically switched on and which on the other hand may be expanded in the future with BACnet. Pro-BACnet are migrated Currently 17 substations type HSC Pro-BACnet are migrated. The data point basis was integrated with the aid of the automatic import function EDE of IBS. Fine adjustments were made by using the integrated BACnet Browser. Actually about 4,500 data points are visualized on the GLT IBSnetview. For the operator this means maximum operating convenience and transparency and thus an optimal and only now economical operation. For the active energy consumption controlling the EIQ-Energy Controlling Programme of the company INGA is currently used. The actual energy data of the GLT are stored in a SQL data base and may be called up subsequently by using a web browser. Consumption data, costs, budget control, CO2 emissions, reports and analyses may thus be easily recorded and visualized. Florian Kienast Prokurist INGA mbH [email protected] www.inga-hameln.de BACnet Europe Journal 12 04/10 33 Another innovative design from the world’s BACnet leader. Visit us at light+building 2010 to experience the world launch of enteliSYSTEMTM – Hall 9.0 Stand E55 Anwendungen Solutions BACnet Integration auf allen Ebenen BACnet Integration at All Levels Die neue Strabag Zentrale im polnischen Pruszków setzt beim Design auf Green Building, auf die Integration aller Gewerke unter eine BACnet Bedienoberfläche und auf CISCO IP Telefone für die lokale Bedienung. The new Strabag Poland headquarters in Pruszków is a green building design with various building services integrated with BACnet, supervised by a BACnet user interface and operated locally by its occupants through CISCO IP telephones. Der österreichische Baukon zern STRABAG SE zählt heute mit rund 73.000 Mitarbeitern und einer Jahresbauleistung von rund 14 Mrd. Euro zu den größten europäischen Baukonzernen. Das Unternehmen ist seit über 160 Jahren in der Bauindustrie tätig und besitzt Nieder lassungen in der ganzen Welt. sund und komfortabel für die Mitarbeiter ist. Architektonisch gesehen ist der Bau sehr modern gehalten, denn die Hauptmerkmale des Gebäudes sind große Innenräume, die durch Glaswände voneinander abgetrennt sind. Dieser Bau ist nicht nur energiesparend, sondern auch sehr umweltfreundlich. STRABAG Sp. z o.o., die pol nische Hauptniederlassung des STRABAG Unternehmens hat ihren Sitz in Pruszków. Die neu gebaute Zentrale besteht aus einem Komplex von zwei hochmodernen Bürogebäuden. Das Ziel dieser Investition war es, ein modernes und ökologisches Gebäude zu bauen, welches ge- Es werden ausschließlich er neuerbare Energien (wie z.B. Erdwärme) für die Heizungs und Kühlanlagen verwendet. Durch eine Wärmepumpe werden u.a. die Fußbodenheizungss ysteme betrieben. Die Argumente für die Wahl einer solchen Lösung waren eindeutig: niedrige Investitionskosten, da mit einer einzigen Installation eine Doppelwirkung erzielt wird; niedrigere Instandhal tungskosten dank der Versor gung von Wärmequellen mit niedrigen Kennwerten; bessere Ausnutzung der Räume, da sie sonst durch traditionelle Heizkörper begrenzt waren. Die Lösung ist außerdem ökologisch und ausreichend zugleich und trägt zu einer angenehmeren Raumtemperatur bei. Ausschließlich erneuerbare Energie Der Einsatz von IP Telefonen für die Steuerung und Bedie nung des Komforts in allen Räumlichkeiten (Temperatur sollwertverstellung oder Bedienung der Fensterja- lousien) verdient besondere Aufmerksamkeit. Bei starker Sonneneinstrahlung senden spezielle Sensoren (von der Wetterstation) Signale an das GA-System und die Fensterjalousien werden automatisch heruntergefahren. Außerdem wurden an den Fenstern Kontakte installiert, so dass eine Kollision zwischen einer Jalousie und einem geöffneten Fenster verhindert wird. Sobald ein Fenster geöffnet wird, wird die Klimaanlage automatisch ausgeschaltet und die Jalousien werden geöffnet. Solch eine technische Lösung mit der Bedienung von IP Telefonen ist sehr hilfreich vor allem in modernen Bauten, mit Innenwänden aus Glas, wo keine Bediengeräte BACnet auf allen Ebenen in der Strabag Zentrale in Pruszków. Strabag Headyquarters Pruszków – BACnet Integration at all levels. BACnet Europe Journal 12 04/10 35 Anwendungen Solutions an den Wänden montiert werden können. Dank dieser Lösung kann die Wetterstation, abhängig von der Zeit und der Stärke der Sonneneinstrahlung, eventuell auch für andere Aufgaben nützlich sein. Das GA-System Das integrative GA-System beinhaltet u.a. folgende Ele mente: 4 Lüftungsanlagen mit Wärmerückgewinnung 200 dezentrale Unterflurlüf tungsgeräte mit Fan Coil mit Leistungskontrolle für Frischluft Zutrittskontrolle für mehr als 30 Türen mit einem automatischen Ausgangsdetektor Integration vom DALI Be leuchtungssystem in den Konferenzräumen Integration eines Einbruch meldesystems und einer Brandmeldeanlage mit mehr als 1.000 Sensoren mit Visualisierung mittels der GLT von Delta Controls BACnet B-AWS Integration von Zählern für elektrische Energie, Wärmeund Kältemengenzähler mittels MBus Protokoll und MBus / BACnet Gateways. CCTV System mit 24 IP Ka meras und 4 High Speed Kameras mit optischem Zoom Integration von USV’s, Prä zisions-Klimageräten, Wär mepumpen und Netzanalysatoren über MODBus / RTU Parkplatzsteuerung Integration von 200 Cisco IP-Telefonen für die lokale Raumbedienung. STRABAG Sp. z o.o. is a daughter company of an Austrian concern, STRABAG SE, one of the first companies registered as a “European Company” (Societas Europea). The company has led the construction market for more than 160 years with offices all over the world. The main office of STRABAG in Poland is based in Pruszków and comprises two ultramodern office buildings, the construction of which has been divided into two stages. In close vicinity of the new office building there are also two other premises within the STRABAG SE concern which house BMTI and the TPA Technical Research laboratory. The entire complex will be completed by 2011. The objective is to create a modern ecological building, with a pleasant working environment. Its architecture is extremely modern, featuring large internal glazed spaces. The building is not just energy efficient, but also environmentally friendly. Exclusively renewable energy Renewable energy is used with the heating-cooling powered by a heat pump based on under floor heating systems. The solution means low investment costs, as the amount of duplicated installation is reduced, and low maintenance costs thanks to a heat source supply with low parameters. The building also benefits from an increase in usable Die neue Strabag Zentrale in Polen, integriert zahlreiches Gebäudesysteme mit BACnet zu einem System. The new Strabag Poland headquarters integrates various building services with BACnet into one system. 36 BACnet Europe Journal 12 04/10 Das Cisco IP-Phone zur lokalen Steuerung und Bedienung. The Cisco IP telephone for local operation and control. available surface area – normally restricted by traditional heating installation. The solution balances ecological needs with the optimization of comfortable ambient temperature. The use of IP telephones is used for comfort control throughout the premises controlling temperatures and window operation. During periods of high solar gain, specialized sensors (from a weather station installed in the building) send signals to the BMS, automatically closing window rollers. Additionally, window contacts ensure closing rollers are not blocked by open windows. Once a window is opened, the air conditioning system is automatically switched off and the roller is opened. The application of IP telephony is sometimes the only option in modern buildings – where the internal walls are made of glass or any other material making electrical installation of wall-mounted sensors impossible. The weather control point is also able perform other tasks depending on the time schedule and degree of sun exposure. The STRABAG BMS installation is constantly evolving, however current features include: 4 ECO AHUs, with heat recovery, 200 sub-floor fan coils with fresh air and efficiency control, Access control for more than 30 doors with an automatic exit detector, Integration with a conference room lighting system using a DALI protocol, Integration with the fire control system (>1000 sensors) with a graphics display at the BMS ORCAview station, A gas extinguishing system in the server room, Integration of 11 electrical meters monitoring heating and cooling according to MBUS protocol, CCTV system based on EXACQ DVR and 24 high quality IP cameras, including 4 high-speed cameras with an optical zoom, Integration of 3 UPS over MOD-BUS protocol, Integration of 2 precision HVAC cabinets over MODBUS protocol, Integration of central heating and LPG monitoring system in the garage area, Integration of a heat pump system (5 compressors using LON / BACnet protocols and a monitoring system for 10 pumps for heat plant and hydrophore centre), Integration of power analyzers over MOD-BUS, Lift visualization, Control of 24 ventilators for various applications, A complete weather station with sun exposure sensors, wind strength and rainfall meters allows for the control of opening and closing of skylights and ventilation flaps, Intrusion system, Garage vehicle movement control (light signaling system), In conference rooms, the placement of division walls is controlled and forms the basis for defining air-conditioning zones, lighting and window rollers, IP CISCO platform integration. 200 telephones are used as local user interfaces (changes of temperature settings, lighting on /off, window rollers control). Delta Controls Poland Andrzej Kołodyn’ ski [email protected] www.deltacontrols.com Anwendungen Solutions Südländisches Flair – Shoppen im Mediterraneo Bremerhaven Shopping at Mediterraneo in Bremerhaven – Southern Flair Presented with Charm and Esprit Der Kellner bringt einen Espresso, auf der Piazza vor dem Cafe erfüllen fröhliche Stimmen die warme, angenehm frische Luft, malerische Gassen laden zum kurzweiligen Bummeln ein. Das Mediterraneo bietet eine entspannte Atmosphäre mediterranen Wohlfühlklimas. Für dieses sorgen Lüftungsanlagen von ALKO. Modernste Frequenzumrichtern VLT® HVAC Drive von Danfoss steuern die Lüfter. Die notwendigen Signale erhalten sie via BACnet-Anbindung an das Leitsystem. The waiter brings an espresso, cheerful voices fill the warm, pleasant fresh air on the piazza in front of the café, and picturesque alleys invite you to go for a short stroll. Mediterraneo bathes you in the relaxed atmosphere of a comfortable Mediterranean climate, courtesy of ventilation systems. Advanced Danfoss VLT® HVAC drives power the fans, and a BACnet link routes the necessary signals to the drives from the control system. Bereits 2008 eröffnete das Mediterraneo, das von der AVW Immobilien AG betrieben wird, und sorgt seitdem für neuen Schwung im Handel. Es bietet auf knapp 9000 m2 eine große Einkaufs- und Erlebniswelt im mediterranen Stil und lädt mit liebevoll und in sanften pastellfarben gehaltenen Fassaden mit insgesamt 40 Geschäften und Restaurants zum Bummeln ein. Das Herz des Mediterraneo bildet die Plaza, über der sich die gläserne Kuppel mit ihren stolzen 58 Metern Höhe zum Himmel reckt. Das graphische Display erlaubt eine einfache Inbetriebnahme und Vor-OrtBedienung. The graphical display allows easy installation and local control. Mediterranes Klima mit VLT® HVAC Drive – warm und angenehm Das Mediterraneo sorgt mit modernsten Lüftungsanlagen für mediterranes Klima, richtige Ferienstimmung kommt auf. So ist die Luft angenehm temperiert. Energieeffizient geregelte Lüfter sorgen für einen optimalen Luftaustausch für die 8.000 bis 10.000 Besucher und Käufer täglich. Insgesamt verfügt das Mediterraneo über vier Lüftungszentralen, in denen neben einer Wärmepumpenanlage auch 18 Zu- und Abluftgeräte ihren Dienst versehen. Die Steuerung der Ventilatoren der Lüftungsanlagen übernimmt der VLT® HVAC Drive, der auf HKL-Anwendungen optimiert ist. Er stellt dafür Sonderfunktionen bereit. Mittels seines modularen Aufbaus erlaubt der VLT® HVAC Drive die einfache und optimale Anpassung an die jeweils benötigte Feldbustechnologie ebenso wie eine angepasste Erweiterung für zusätzliche Einund Ausgänge oder eine externe 24 V DC Versorgung. Im Mediterraneo erfolgt die Feldbusanbindung mittels der optionalen BACnet-Erweiterungskarte, die im Vergleich zur standardmäßig integrierten BACnet-Anbindung noch mehr Möglichkeiten bietet. Einfache Einbindung in ein Gebäudeleitsystem Bereits serienmäßig verfügt der VLT® HVAC Drive FC 102 über alle notwendigen Funktionen zur einfachen Einbindung in ein Gebäudeleitsystem. So lassen sich Ist- und Sollwerte zwischen den Systemen übertragen und Datenpunkte setzen und auslesen. Die Schnittstelle unterstützt den Standard ISO 16484-5 und die Kommunikation erfolgt gemäß dem Client-Server-System. Für noch mehr Funktionalität sorgt die VLT® BACnet MCB 109, die in dieser Anwendung zum Einsatz kommt und den BACnet MS / T P-Standard erfüllt. Sie lässt sich jederzeit einfach nachrüsten oder bereits werksseitig bestellen. Mit BACnet MS / T P können die Antriebe direkt über das BACnet Protokoll mit anderen BACnet Geräten kommunizieren. Alle Einstellungen sind direkt über das BACnet Protokoll möglich und der Anwender benötigt keine zusätzliche Software für die Inbetriebnahme. Bedingt durch den einfachen physikalischen Aufbau ist BACnet MS / T P weiter auf dem Vormarsch und ideal für eine Buskommunikation in der Feldebene. Zudem kann die Verkabelung kostengünstig über eine einf ac h e Zwe id r a ht- R S 485 Technologie erfolgen. BACnet Europe Journal 12 04/10 37 Anwendungen Solutions Malerische Gassen wecken beim Besucher die Illusion, mit südländischem Flair und Charme zu shoppen. Mediterraneo offers a Mediterranean style shopping experience with the façades of its forty shops and restaurants, all tastefully designed in pastel colours. Mediterraneo, which is operated by AVW Immobilien AG, opened in 2008 and has given the retail world a new flair since then. With an area slightly less than 9,000 square metres, it houses a large shopping centre offering a Mediterranean style shopping experience with the façades of its forty shops and restaurants, all tastefully designed in pastel colours, inviting visitors to stroll around. The heart of Mediterraneo is the Plaza, which is covered by a glass dome that proudly rises to a height of 58 metres. A warm and pleasant Mediterranean climate with VLT® HVAC drives Mediterraneo creates a true holiday spirit by using advanced ventilation systems to provide the right climate. It maintains a pleasant atmosphere. Energy-efficient speed-controlled fans ensure optimal air exchange for the 8,000 to 10,000 visitors and shoppers each day. Medi- Insgesamt sorgen 18 Zu- und Abluftgeräte für ein optimales, mediterranes Klima. Mediterraneo has four ventilation clusters in total, serviced by a heat pump system and eighteen intake and exhaust units. 38 BACnet Europe Journal 12 04/10 terraneo has four ventilation clusters in total serviced by a heat pump system and eighteen intake and exhaust units. The fans in the ventilation systems are powered by VLT® HVAC drives, which are optimised for HVAC applications. They provide special functions for this purpose. Thanks to their modular construction, VLT® HVAC drives enable easy, optimal adaptation to the fieldbus technologies required by specific applications, as well as suitable extensions for supplementary inputs and outputs or an external 24 V DC supply. The fieldbus connection at Mediterraneo is provided by the optional BACnet extension card, which offers even more features than the standard integrated BACnet connection. Easy integration into building control systems The VLT® HVAC Drive FC 102 comes as standard with all necessary functions for easy integration into building control systems. It allows setpoint and actual values to be exchanged between system components, and da- ta points to be set and read out. The interface supports ISO standard 16484-5, with client / server communication. The VLT® BACnet MCB 109 used in this application provides even more functionality and complies with the BACnet MS / TP standard. It can be easily retrofitted at any time or ordered as a factory option. BACnet MS / TP enables the drives to communicate directly with other BACnet devices via the BACnet protocol. All settings can be configured directly using the BACnet protocol, and the user requires no additional software for commissioning. Thanks to its simple physical architecture, BACnet MS / TP is steadily gaining ground and is ideal for bus communication at the field level. In addition, the cabling can be installed inexpensively using simple twowire RS485 technology. Burkhard Bär Verkaufsingenieur Danfoss GmbH VLT Antriebstechnik [email protected] www.danfoss.de / vlt Anwendungen Solutions Erstes BACnet Projekt in der Türkei – Istanbul Atatürk International Airport Turkish Debut for BACnet at the Istanbul Atatürk International Airport Der Istanbul Atatürk International Airport nahm im Jahr 2000 seinen Betrieb auf. Diese wichtige internatio nale Drehscheibe war weltweit eines der ersten Flughafenprojekte, das nach dem BOT-Betreibermodell („Build-Operate-Transfer“) umgesetzt wurde. The Istanbul Atatürk International Airport in Turkey, opened in January of 2000. This major international airport was also one of the first airport projects in the world to have been undertaken as a Build-OperateTransfer model. TAV Airport Holdings, das führende Flughafenunternehmen in der Türkei, war nicht nur Bauherr, sondern ist auch der Betreiber des Istanbul Atatürk International Airport und seiner zahlreichen Erweiterungen, von denen die letzte im Jahr 2010 fertig gestellt werden soll. TAV wurde 1997 als Joint Venture von Tepe und A kfen nach deren erfolgreichen Teilnahme an der Ausschreibung für das Istanbul Atatürk Airport International Terminal gegründet. Integration als Schlüsselrolle Ziel von TAV Airports ist die Führungs- und Vorreiterrolle als Flughafenbetreiber in den Zielregionen Osteuropa, Kaukasus, Naher Osten und Nordafrika. Dies soll durch zuverlässige und integrative Lösungen mit dem Schwerpunkt auf Komfort und Sicherheit für Pächter und Passagiere erreicht werden. Es wurde sehr schnell deutlich, dass bei der erfolgreichen Koordinierung zahlreicher verschiedener Systeme wie Heizung, Lüftung und Klimatechnik (HLK) sowie Kühlung, Beleuchtung, Fluggastbrücken, Gepäckabfertigung und Brandmeldeanlagen der Integration eine Schlüsselrolle zu kommt. Der türkische Alerton Partner BTS (Bina Teknlojik Sistemleri) gewann die Ausschreibung für das komplexe Gebäudeautomationssystem des Flughafens. Nach der Vergabe des Auftrags sprach sich BTS für den Einsatz von BACnet aus, da diese Lösung optimal für die Vernetzung der verschiedensten Systeme geeignet ist. Die Empfehlung wurde von den beteiligten Parteien umgesetzt. Dies ist insbesondere deshalb bemerkenswert, da BACnet damals in der Türkei relativ unbekannt war. Der Atatürk Airport stellte somit das erste BACnet-System des Landes dar. BACtalk-System Dabei kam das BACtalk-System von Alerton zum Ein- satz. Durch diese BACnetLösung werden alle Bereiche der Gebäudeautomation integriert. Dies ermöglicht TAV als Betreiber des Atatürk Airports ein umfassendes Gebäudemanagement. Nach drei umfangreichen Systemerweiterungen in den letzten zehn Jahren erwies sich BACtalk als gute Wahl. Ein Ausbau über mehrere Jahre hinweg kann zu Problemen bei der Produktkompatibilität führen, was durch den Einsatz der Alerton Produkte vermieden wurde. Hakan Ozbek, Geschäftsführer von BTS, gewährt einen Einblick: „Zuerst setzten wir LSI Regler ein, dann für die Erweiterung des internationalen Terminals die Nachfolgeregler BTI. Für das später folgende Inlandsterminal wurde dann die BCM Generation installiert. Heute verarbeiten die Geräte aller drei Generationen nahtlos Daten von mehr als 15.000 Einund Ausgängen. Dies ist ein klarer Beleg für die Vorteile der Abwärtskompatibilität, auf die Alerton besonderen Wert legt.“ Hakan Ozbek erklärt: „BTS ist sehr stolz, dass der Atatürk Airport 2009 bei einer Umfrage von Skytrax (einem unabhängigen Beratungsunternehmen der Luftverkehrsindustrie) als zweitbester Flughafen in Südeuropa abgeschnitten hat. Einer der Hauptgründe für diese positive Bewertung war nach Angaben der befragten Passagiere die Klimatisierung. Es freut uns sehr, dass wir mit unserer Arbeit einen großen Beitrag zum Erfolg des Flughafens leisten konnten.“ Neben der Beteiligung beim Atatürk International Airport arbeitete BTS an drei weiteren großen Flughafenprojekten von TAV (Ankara, Izmir und Enfidha [Tunesien]) mit, bei denen ebenfalls das BACtalk-System auf Grundlage von BACnet zum Einsatz kam. BACnet Europe Journal 12 04/10 39 Anwendungen Solutions Das erste BACnet Projekt in der Türkei – der Istan buler Atatürk International Airport. The Istanbul Atatürk International Airport – the first BACnet system in the country. TAV Airports Holdings, the leading airports operator in Turkey not only constructed but also operates the Istanbul Atatürk International Airport and its numerous extentions, the latest being slated for completion in 2010. TAV was established in 1997 as a joint venture between the Tepe and Akfen Groups, following their successful bid for the Istanbul Atatürk Airport International Terminal contract. Integration plays an important role TAV Airports’ vision is to become the leader and the pioneer airport operating company in its targeted regions of Eastern Europe, the Caucasus, Middle East and North Africa by providing reliable, integrated solutions with a focus on comfort and security for both tenants and guests. It became clear that integration would play an important role in successfully controlling and coordinating its many systems such as heating, ventilation and air conditioning (HVAC), chillers, lighting, passenger boarding bridges, baggage handling, and fire alarms. Alerton’s Turkish dealer, BTS (Bina Teknlojik Sistemleri), applied to provide the complex building automation system for the airport and won. After the Atatürk Airport International Terminal contract was awarded, BTS recommended using BACnet to all the parties involved, since it best addressed the need to integrate the systems. The recommendation was accepted, despite little recognition of BACnet at that time in Turkey, so Atatürk became the first BACnet system in the country. BACtalk system BTS used Alerton’s BACtalk system, which uses BACnet at each level of the building automation system, to provide a powerful, integrated building management system for the Atatürk aiport operated by their customer TAV. BACtalk proved to be a good choice, judging by the three major system extensions that were done over 40 BACnet Europe Journal 12 04/10 the last ten years. Spreading various extensions out over several years can create product compatibility issues – but not with the Alerton products. Hakan Ozbek of BTS revealed the following: “We used LSI global controllers in the first phase, then their successors-Alerton BTIs (BACtalk Integrators)for the international terminal extension, then BCM (BACtalk control modules) for the domestic terminal. Now all three generations of global controllers operate over 15,000 inputs and outputs in perfect harmony, which is good proof of Alerton’s strong focus on backwards compatibility.” Hakan Ozbek, BTS’s managing director said, “BTS was delighted to learn that Atatürk was voted the second best airport in Southern Europe in a 2009 survey by Skytrax (the independent research advisors to the air transport industry). We hear that passengers interviewed said a major reason for their positive opinion of Atatürk was the air conditioning. We’re very proud of that and delighted to have played a major part in the airport’s success.” In addition to Atatürk, BTS delivered three other major airport projects for TAV including Ankara, Izmir, Enfidha-Tunisia, which all use Alerton’s BACtalk system based on BACnet. Christine Scheier Channel Marketing Manager Alerton EMEA christine.scheier@ alerton.com Anwendungen Solutions CargoCity Süd – Gerüstet für weiteres Wachstum CargoCity South – Ready to Expand Im Süden des derzeitigen Flughafenareals expandiert der Flughafen Frankfurt am Main weiter mit der CargoCity Süd. SAMSON sorgt im neuen Logistikzentrum für angenehmes Klima. Frankfurt International Airport is further extending its area by expanding CargoCity South. SAMSON provides the new logistics center with a pleasant climate. Als Betreibergesellschaft des Flughafens Frankfurt am Main (FRA) ist die Fraport AG für den sicheren und wirtschaftlichen Betrieb von FRA verantwortlich. Mit rund 19.000 Beschäftigten (inkl. Beteiligungsunternehmen) am Standort Frankfurt am Main ist der Fraport-Konzern nach der Lufthansa das bedeutendste Luftverkehrs-Unternehmen Deutschlands. Die Frachtumschlagskapazität des Flughafens Frankfurt am Main wird durch die CargoCity Süd deutlich ausgeweitet: Im Jahr 2010 soll sie bei 2,8 Millionen Tonnen liegen. Mit den Gebäudeabmessungen von 172 m x 72 m, einer Höhe von ca. 27 m und einer Grundfläche von über 10.000 m² dominiert das Logistikzentrum (Geb. 568) die neue CargoCity Süd. Im Tiefgeschoss des imposanten Gebäudes befinden sich ca. 300 Parkmöglichkeiten. Das gesamte Erdgeschoss bildet die 172 m x 52 m große, zweigeschossige Lagerhalle mit zugehöriger Anlieferungszone. Darüber befinden sich Büro-, Umkleide-, Wasch- und WC-Räume. Das Automationssystem TROVIS 6600 ist über vier Informationsschwerpunkte Anlagengrafik: Raumlufttechnische Anlage 7 Süd (GLT SAMSON). Plant scheme: Ventilation Plant 7 South (building automation by SAMSON). (ISPs) verteilt im Einsatz, zwei ISPs in den Technik räumen „Tiefgeschoss“ und zwei ISPs in den Technikräumen „Obergeschoss“. Fraport AG setzt auf BACnet Wie bereits mehrfach im BACnet Journal berichtet, setzt die Fraport AG auf BACnet. Mit dem CPU-Modul TROVIS 6610 (zertifizierter BACnet Building Controller (B-BC)) stand somit der Anbindung an bestehende BACnet Operator Workstation Softwares (B-OWS) nichts im Wege. Die Wärmeversorgung des Logistikzentrums erfolgt mit einem Gaskessel. Über einen Vorlauf- und Rücklaufsammler verteilt sich die gewonnene Wärme in die raumlufttechnischen Anlagen Nord und Süd sowie in die statische Heizung. Für eine optimale Ausnutzung der Wärme sind die raumlufttechnischen Anlagen mit einer rekuperativen Wärmerückgewinnung (Kreuzstromwärmetauscher) ausgestattet. Diese arbeitet mit den Lufterhitzern in Sequenz. Die Luftmengen werden über frequenzumformergeregelte Ventilatoren eingestellt. Betriebs- und Störmeldungen werden vom System eingelesen Sämtliche Betriebs- und Störmeldungen aus der Heizungs- und Lüftungszentrale sowie aus dem Serverraum (Überwachung der Lösch- und Kühlsysteme) werden ebenfalls vom System eingelesen und verarbeitet. Über den standardisierten KNX-Bus erfolgt die Lichtsteuerung. Zusätzlich werden einige Betriebs- und Störmeldungen aus dem Gewerk Elektro über KNX eingelesen, z. B. Auslösung Überspannungsschutz, Türschleusenkontakte, Notstromdiesel usw. Bedienung über die Direktbedienebene Bus-tec Eine Bedienung der A nlage am Informationsschwerpunkt ermöglicht die Direktbedienebene Bus-tec (Fa. Romutec). Die Anbindung der Direktbedienebene an die CPU-Module T ROVIS 6610 erfolgt über Modbus RTU. Die CPU-Module T ROVIS 6610 sind in das bauseitige Firmennetzwerk eingebunden. Die Visualisierung des kompletten Logistikzentrums erfolgt über BACnet/IP mit der bestehenden Leitzentrale der Firma JCI im Gebäude 420. Um auch im Logistikzentrum maximale Transparenz über die Anlage zu erhalten, wurde eine Gebäudeleittechnik von SAMSON eingesetzt. Die Gebäude sind mit Lichtwellenleiter verbunden. Alle physikalischen sowie ausgewählte virtuellen Da- BACnet Europe Journal 12 04/10 41 Anwendungen Solutions Flughafen Frankfurt: Logistikzentrum in der CargoCity Süd. Frankfurt International Airport, logistics center at CargoCity South. tenpunkte sind als BACnetObjekte in den CPU-Modulen TROVIS 6610 hinterlegt. Ebenfalls stehen die eingelesenen KNX-Informationen als BACnet-Objekte zur Verfügung. Fraport AG is in charge of the safe and profitable operation of Frankfurt Airport. With around 19,000 employees (including affiliated companies) at the Frankfurt site alone, Fraport is the secondlargest German air traffic company, surpassed only by Lufthansa. CargoCity South considerably expands the airport’s cargo handling capacity in 2010 it is expected to reach 2.8 million metric tons. With dimensions of 172 x 72 m, a height of approx. 27 m and a floor space of over 10,000 m², the new logistics center (Building 568) dominates the new CargoCity South. The basement level of the impressive building provides almost 300 parking spaces. The ground and first floors house the 172 x 52 m storage area and associated loading zone. On top of these floors, there are offices, staff rooms, showers and toilets. The TROVIS 6600 Automation System is distributed across four information centers: two centers in the technical installations room for the basement, two centers in the technical installations room for the upper floors. System reads all status and alarm messages The system also reads and processes all status and alarm messages from the heating and ventilation control station as well as the server room (monitoring of fire-fighting and cooling systems). Fraport relies on BACnet As often reported in the BACnet Journal, Fraport AG relies on BACnet. As a result, the TROVIS 6610 CPU Module (certified BACnet Building Controller (B-BC)) could easily be integrated into existing BACnet Operator Workstation Softwares (B-OWSs). Gas boilers are used to supply the logistics center with heat. Using a flow and a return flow collector, the generated heat is distributed to the north and south ventilation systems as well as radiators. To optimally use the heat, the ventilation systems are equipped with recuperative heat recovery (cross-flow heat exchangers). They work in sequence with the air heaters. The air capacity is adjusted using VFD-controlled fans (Variable Frequency Drive). Lighting is controlled using the standardized KNX bus. Additionally, some status and alarm messages issued by the electrical installations are also read using KNX, e.g. activation of surge protection, gate contacts, emergency diesel generators, etc. 42 BACnet Europe Journal 12 04/10 Direct operating level Bus-tec The direct operating level Bus-tec (by Romutec) allows the plant to be operated at the information center. It is connected to the TROVIS 6610 CPU Modules by Modbus RTU. The TROVIS 6610 CPU Modules are integrated into the corporate network on site. The entire logistics center is visualized using BACnet/IP in the existing control center by JCI in Building 420. To get the best possible overview of the plant even in the logistics center, a building automation system by SAMSON has been installed. The buildings are connected by fiber optic cables. All physical and selected virtual data points are saved as BACnet objects in the TROVIS 6610 CPU Modules. The transmitted KNX data are also available as BACnet objects. André Strauch SAMSON Aktiengesellschaft [email protected] www.samson.de Anwendungen Solutions Vorne Show, hinten BACnet im FriedrichstadtPalast Curtain Call with BACnet behind the Scenes Der Berliner FriedrichstadtPalast ist ein Ort der Superlative: Die größte Theaterbühne, die längste Girlreihe und die größte fahrbare Eisfläche der Welt, dazu ein in Inhalt und Größenordnung europaweit einzigartiges Programm mit Shows von Weltklasse-Format. Eine Bilderflut voller Tanz, Spitzenakrobatik und Musik begeistert allabendlich knapp 2.000 Gäste. Im Hintergrund arbeitet Gebäude automation von Kieback&Peter, kommuniziert gewerkeübergreifend mit BACnet und sorgt für sicheren Gebäudebetrieb, Energieeffizienz und Komfort. The Berliner FriedrichstadtPalast is a place of superlatives: having the largest theatre stage, the longest female chorus line as well as the world’s largest mobile ice-skating rink. Its vast magnitudes and dimensions feature the most unique show program that Europe has to offer in a world-class format. A flood of images full of dance, acrobatics and music inspire nearly 2,000 guests every night. Behind the scenes, building automation from Kieback&Peter is at work with trade spanning communication via BACnet. It guarantees secure building operation, energy efficiency and comfort. Im Gebäude des Neuen FriedrichstadtPalastes, 1984 an der Friedrichstraße eröffnet, sind alle wichtigen Räume des Theaters wie Verwaltung, Proberäume und Werkstätten untergebracht. Zentrale Elemente sind der Zuschauerraum und die rund 2.800 Quadratmeter große Bühne, ausgestattet mit moderner Bühnentechnik: Riesige LED-Bänder sorgen für Licht-Feuerwerke, computergesteuerte Ventile zaubern einen Regenvorhang, über 1.200 Schein- werfer, zehn Video-Großprojektoren und 150 Moving Lights setzen das Ensemble und die Solisten ins rechte Licht. Ein aus der Unterbühne ausfahrbares Wasserbecken hat ein Fassungsvermögen von 170.000 Litern, die fahrbare Eisfläche misst 340 Quadratmeter. Moderne Gebäude automation mit DDC4000 Schon bei der Eröffnung war das Gebäude mit Leittechnik ausgestattet. Den aktuellen Anforderungen 44 BACnet Europe Journal 12 04 / 10 konnte dieses System aus DDR-Zeiten aber nicht mehr gerecht werden. Deshalb entschloss sich die Senatsverwaltung Berlin als Eigentümer und Bauherr, ein modernes Automationssystem DDC4000 von Kieback&Peter zu installieren. Das Besondere: Die vorhandene Anlagentechnik für Lüftung, Heizung und andere Gewerke blieb weitestgehend erhalten und wurde bei laufendem Spielbetrieb in das Gebäudeautomationssystem integriert. Kieback&Peter übernahm dabei auch Leistungen außerhalb der Gebäudeautomation und ließ diese durch Fachfirmen durchführen. Gewerkeübergreifende Kommunikation mit BACnet Heute hat das System 16 Informationsschwerpunkte. Ein vorhandenes Automationssystem DDC3000 für die Heizung wurde nahtlos integriert. Zehn Automationsstationen DDC4400 überwachen und steuern über das Anwendungen Solutions tion monitor and control the ventilation systems, cold water temperatures and light controls via the BACnet protocol. In addition, utility meters for electricity and heat were integrated, as were sensors to monitor water temperature and water level in the large pool. © Foto: Stephan Gustavus, xix; Kostueme: Stefan Bolz Der FriedrichstadtPalast ist einzigartig in seinem Showprogramm und in seinen Dimensionen. The FriedrichstadtPalast is unique in its show program and in its dimensions. BACnet-Protokoll die Lüftungsanlagen, Kaltwassertemperaturen und die Lichtsteuerung. Integriert wurden außerdem Verbrauchszähler für Strom und Wärme. Integriert ist auch das große Wasserbecken, wo Sensoren Wassertemperatur und Füllstand überwachen. © Christian Lietzmann Gebäudemanagement mit Neutrino-GLT Das Gebäudemanagement mit einer Neutrino-GLT kommuniziert ebenfalls über BACnet. Der zentrale Leitstand hat zwei Bedienplätze. Weitere Bedienplätze sind am Arbeitsplatz des Pförtners und – über PHWIN – im Büro des Technischen Direktors. Mit der Neutrino-GLT haben die Haustechniker alle Anlagen im Griff. Störungen in den An- lagen werden über Störmeldungen sofort angezeigt und können schnell lokalisiert und beseitigt werden. Über die Gebäudeautomation von Kieback&Peter konnte die komplexe Anlagentechnik mit rund 2.000 Datenpunkten vollständig in ein übergreifendes System integriert werden. Die Überwachung und Steuerung wurden verbessert und der Anlagenbetrieb optimiert. Das standardisierte Protokoll BACnet bindet auch Fremdgewerke ein. Erweiterungen und Modifizierungen sind problemlos möglich. The FriedrichstadtPalast building on Friedrich Strasse opened its gates in 1984; it houses all important rooms of the theatre such as administration offices, rehearsal rooms and dance studios. Central elements are the auditorium and the roughly 2,800 square meter stage, equipped with modern stage equipment: giant LED strips provide lighting fireworks, computer-controlled valves conjure up a rain curtain, and over 1,200 spotlights, ten video projectors and 150 moving lights place the ensemble and soloists in the right light. An extenda- ble water basin from below the stage has a capacity of 170,000 liters and the mobile ice rink measures 340 square meters. Modern building automation with the DDC4000 The building was equipped with building automation upon opening. However, since in dates back to the GDR era the system could not measure up to today’s requirements. Therefore, the building owner and builder, the Berlin Senate, decided to install the modern DDC4000 automation system from Kieback&Peter. In particular, the existing installation engineering for ventilation, heating and other trades remained largely preserved and were integrated into the building automation system while the theatre was in full operation. Kieback&Peter also took over responsibility for services outside of building automation and outsourced them to various expert companies. Trade spanning communication with BACnet Presently the system offers 16 sets of controllers. The existing DDC3000 automation system was perfectly integrated for heating. Ten DDC4400 automation sta- Der große Saal bietet 1.895 Besuchern Platz. The main hall has a seating capacity of 1895. Building management with Neutrino-GLT The Neutrino-GLT building automation system likewise communicates via BACnet. The central control station has two operating stations. Other terminals are stationed at the doorman’s workspace and – via PHWIN – in the office of the technical director as well. Therefore, through the operation of the NeutrinoGLT, house technicians have the entire plant under control. Disturbances in the systems are instantly displayed by error messages and can be quickly located and solved. Through the building automation from Kieback&Peter the complex installation technology can be fully integrated into a comprehensive system with approximately 2,000 data points. The monitoring and control have been improved and have optimized plant operation. The standardized BACnet protocol also integrates subcontractors, making, extensions and modifications possible without problems. Thomas Ernst Niederlassung Berlin / Brandenburg Kieback&Peter GmbH & Co. KG [email protected] www.kieback-peter.de BACnet Europe Journal 12 04/10 45 Anwendungen Solutions Komplexe Automation – einfach umweltfreundlich Simply Green – BACnet / IP Ensures Energy-Efficient Building Automation and Long-Term Flexibility Die Pforzheimer Alfons-Kern-Schule zieht um. Als erste Bildungsstätte in Baden-Württemberg wird die Berufsschule von einem privaten Investor gebaut und für die nächsten 30 Jahre bewirtschaftet. Dadurch werden Millionen eingespart – und das Maximum an moderner energiesparender Bauweise erreicht. Möglich macht das der Partner in diesem Public-Private-Partnership-Projekt: Die BAM Deutschland AG legt als eines der führenden Bauunternehmen Deutschlands höchsten Wert auf ausgezeichneten Baustandard. The Alfons-Kern training center in Pforzheim is moving. This vocational school will be the first training center in the state of Baden-Württemberg to be built and managed for the next 30 years by a private investor. This will save millions and at the same time provide for optimal, modern, energy-efficient construction. This is made possible by the partner in this public-private partnership project, BAM Deutschland AG, one of the leading construction companies in Germany, which places great value in excellent construction standards. In der neuen Alfons-KernSchule spiegelt sich die Firmenphilosophie der BAM in einem ökologisch orientierten Baukonzept wider. Heizkörper wurden vollständig durch neueste Betonkernaktivierung ersetzt, klassische Beleuchtung gegen helligkeitsabhängige Konstantlichtregelung ausgetauscht und herkömmliche Jalousien von sonnenstandsabhängiger Verschattung abgelöst. „Der Wechsel von den altbewährten, aber wenig effizienten Installationen hin zu modernsten Technologien wie den thermoaktiven Bö- den und Decken zog natürlich auch eine Umstellung auf komplexe Gebäudeautomation mit sich“, erklärt Walter Dannecker, Vorstandsmitglied und Projektleiter bei der Hörburger AG, die für die ausführenden Arbeiten an der Alfons-Kern-Schule verantwortlich ist. Die Grundlage der neuen Gebäudetechnik bildet das modular aufgebaute und feldbusunabhängige I / O -System 750 von Wago. Via BACnet / I P kommunizieren insgesamt mehr als 70 Wago-BACnetController über ein autarkes Ethernet-Netzwerk mit der Gebäudeleittechnik. 46 BACnet Europe Journal 12 04/10 Dezentraler Aufbau ermöglicht raum individuelle Steuerung In jeder Etagendecke eines Gebäudes sind durchschnittlich vier bis fünf individuell angefertigte Systemverteiler untergebracht. Jeder von ihnen ist mit einem eigenen BACnetController sowie speziellen Wago-Masterklemmen ausgestattet. „Über diesen dezentralen Aufbau ermöglichen wir die raumindividuelle Steuerung und Regelung der Temperatur, der Beleuchtung, der Jalousien und der Lüftung“, beschreibt Diplomingenieur Walter Dannecker. Dazu sind in der Gebäudeleittechnik rund 6.000 Hardwareund mehr als 4.000 virtuelle Datenpunkte hinterlegt. Alle Einstellungen – von der Anwendungen Solutions grundlegenden Programmierung bis zur simplen Parameteränderung – können visuell am Computer vorgenommen werden. Aktualisierungen werden über die BACnet-Kommunikation direkt in den Wago-Controller geladen und dort lokal abgearbeitet. Im Fall einer Netzwerkstörung funktioniert jeder Regler uneingeschränkt weiter. BACnet / IP – weit verbreitet und herstellerunabhängig Seit September 2009 wird in drei von insgesamt vier neuen Gebäudekomplexen unterrichtet. Der vierte Komplex soll im September 2010 bezugsfertig sein. Geplant und ausgeschrieben hat die BAM ursprünglich mit LON. Dass schlussendlich doch BACnet / I P zum Einsatz gekommen ist, dafür ist nicht zuletzt die weite Verbreitung und die große Herstellerunabhängigkeit dieses Protokolls verantwortlich. Die Stadt Pforzheim plant zudem bereits ein stadtweites FacilityManagement-Netzwerk, das ebenfalls auf BACnet / I P basiert und alle Liegenschaften miteinander vernetzen soll. „Mit der Entscheidung für BACnet / I P haben sich Bauunternehmen und Stadt die Option offen gelassen, die Alfons-Kern-Schule in Zukunft ebenfalls an dieses Netzwerk anzubinden“, fasst Walter Dannecker abschließend zusammen. BAM’s company philosophy is reflected in the ecologically oriented construction concept for the Alfons-Kern training center. Radiators will be replaced completely by the latest concrete core activation system, classic lighting by brightness-controlled constant light regulation and normal blinds by shading regulated as a function of sunshine. Walter Dannecker, member of the managing board and project manager at Hörberger AG, responsible for carrying out the work at the Alfons-Kern school explains that: “The transition from tried and true, but less efficient installations, to the latest technologies, such as the thermoactive floors and ceilings of course meant that more complex building automation would be required.” The WAGO modular and fieldbus-independent I / O system 750 forms the basis for this new building automation technology. A total of more than 70 WAGO BACnet controllers communicate via BACnet / IP through an independent Ethernet network with the building I&C system. Individual room control and regulation An average of four to five individually produced system distribution boxes are installed in the ceiling of each floor of the building. Each of these boxes is equipped with a dedicated BACnet controller and special WAGO master modules. Engineer Walter Dannecker explains that: “We can provide for individual room control and regulation of temperature, lighting, blinds and ventilation using this decentralized configuration.” The building I&C system contains around 6,000 hardware points and more than 4,000 virtual data © Drees & Sommer GmbH, Stuttgart Die Pforzheimer Alfons-Kern-Schule – das Maximum an moderner energiesparender Bauweise wurde erreicht. The Alfons-Kern training center in Pforzheim provides for optimal, modern, energy-efficient construction. points for this. All settings, from basic programming up to simple parameterization, can be visualized and performed at the computer. Updates are loaded directly via BACnet communication to the WAGO controllers, where they are then processed locally. In the event of a network disturbance, each controller will continue to operate independently at its full capabilities. BACnet / IP – extensive use in the business Courses have been underway since September 2009 in three of the four new building complexes. The fourth complex is to be completed in September 2010. BAM originally planned and tendered this project with LON. The fact that BACnet / IP was ultimately chosen for the project can in the end be attributed to this protocol’s extensive use in the business and to the freedom this protocol allows in choosing suitable manufacturers. The city of Pforzheim is now also planning a city-wide facility manage- Das modualr aufgebaute und feldbusunabhängige I / O-System 750 von Wago bildet die Grundlage der neuen Gebäudetechnik. The WAGO modular and fieldbus-independent I / O system 750 forms the basis for this new building automation technology. ment network that will also be based on BACnet / IP and will link all sites with one another. As Walter Dannecker summarizes, “Through their selection of BACnet / IP, construction companies and the city kept the option open of also linking the Alfons-Kern school to this network in the future.” Stefan Keggenhoff contecco GmbH [email protected] Hans-Dieter Kohde Market Management Gebäudeautomation WAGO Kontakttechnik GmbH & Co. KG www.wago.com [email protected] BACnet Europe Journal 12 04 / 10 47 Anwendungen Solutions Frischer Wind für Schulen A Fresh Breeze Sweeps through German Schools Rund 20.000 Schulen in Deutschland sind sanierungs bedürftig. Jahrzehntelang stand den Kommunen dafür kaum Geld zur Verfügung, jetzt soll das Konjunktur programm II Abhilfe bringen. Die Kosten sollten sich schon bald amortisieren, denn durch energetische Sanierung kann der Energieverbrauch einer Schule durchschnittlich um 70 % gesenkt werden. Da ungefähr die Hälfte der jährlichen Energiekosten einer Kommune auf Schulen entfallen, sind erhebliche Einsparungen möglich. Around 20,000 schools in Germany are in need of refurbishment. For decades, local government had scant funds for renovations, but now the German Economic Stimulus Plan II should provide relief. The costs should amortize within a short timeframe, because refurbishment will reduce the energy consumption of a school by 70 % on average. Since schools account for approximately half of the yearly energy costs of a local authority, considerable savings can be made. Mechanische Lüftung durch dezentrale Lüftungsgeräte Vielfach ist in den Klassenzimmern keine mechanische Lüftung vorhanden. Unzureichende Lüftung verur sacht nicht nur Schimmelbefall, sondern führt auch zu Konzentrationsschwäche, Kopfschmerzen, Unwohlsein und damit zu einem Leistungsabfall der Schüler und auch der Lehrkräfte. Speziell zur Sanierung von Klassenzimmern hat die TROX GmbH dezentrale Lüftungsgeräte vom Typ TROX SCHOOLAIR entwickelt, die über den BACnetRegler b3 867 aus der Andover-Continuum-Serie von Schneider Electrics Buildings Business angesteuert werden. Der Einsatz von ECRadialventilatoren garantiert Energieeffizienz. Diese laufen sehr leise, so dass sie keine störenden Geräusche für den Unterricht erzeugen. Eine integrierte Wärmerückgewinnung verhindert, dass die Wärme der Raumluft ungenutzt nach außen ab- geführt wird. Einströmende Frischluft wird im Winter über Wärmetauscher vorgeheizt. Im Sommer kann die Zuluft über den Bypass der Wärmerückgewinnung direkt zur freien Kühlung genutzt werden. Kombination von Temperatur- und Luftqualitätsregelung Der frei programmierbare BACnet-Einzelraumregler Andover Continuum b3 867 übernimmt die Ansteuerung der Außenluftklappen, der WRG-Bypassklappe, des Erhitzer- und gegebenenfalls Kühlventils, der Ventilatoren (3-stufig) sowie die Erfassung und Verarbeitung der Zulufttemperatur. Der Zusammenschluss mehrerer Lüftungsgeräte und somit ihrer BACnet-Controller erfolgt über BACnet-MS / TP. Einer der Controller übt zusätzlich Masterfunktionen aus. Dazu wird er mit einem Raummodul STR504 verbunden. Dieses erfasst die Raumtemperatur und fordert über einen Präsenztaster 48 BACnet Europe Journal 12 04/10 die Betriebsart an. Über einen Sollwertsteller kann der vorgegebene Raumsollwert um bis zu 5 K abgesenkt oder angehoben werden. Zusätzlich erhält der Master-Controller über einen Außentemperaturfühler oder optional über Netzwerk die Außentemperatur. Ein VOC-Fühler in der Abluft liefert die Luftqualität. Unterrichts-, Abwesenheitsund Standby-Zeiten sind durch einen Scheduler vorgegeben, wobei die jeweilige Betriebsart über den Präsenztaster am Raummodul übersteuert werden kann. Regelung während der Unterrichtszeit Basierend auf dieser Standardkonfiguration führt der b3 867 während der Unterrichtszeit sowohl eine Temperaturregelung über die Raumtemperatur als auch eine Luftqualitätsregelung durch. So werden Komfortbedingungen genau für die gewünschten Belegungszeiten erzielt. Außerhalb dieser Zeiten wird unnöti- ger Energieverbrauch durch Standby-Betrieb vermieden. Eine von Schneider Electrics Buildings Business entwickelte und über BACnet MS / TP angeschlossene Steuereinheit stellt sicher, dass auch nach etwaigem Spannungsausfall mit den korrekten Zeitprogrammen weitergearbeitet wird. Zur zentralen Bedienung können alle b3 867 Controller auf einen mit Webserver ausgestatteten BACnet Building Controller (B-BC) aufgeschaltet werden. Die Kommunikation zwischen den Reglern ist eine zwingende Voraussetzung dafür, dass das Gebäude in die Energieeffizienzklasse A oder B gemäß EN 15232 eingestuft werden kann. Um übergeordnetes Monitoring durchführen zu können, Alarme an eine Zentrale weiterzuleiten usw., kann der BBC über BACnet / IP in ein BACnet-Leitsystem integriert werden. Anwendungen Solutions BACnet IP BACnet Building Controller mit Webserver Luftqualität Abluft BACnet MS/TP Außentemperatur Raummodul STR504 b3 867 (Master/Slave) b3 867 (Slave) b3 867 (Slave) Zustandsanzeige Betriebsartanforderung Sollwertanforderung Raumtemperatur Zulufttemperatur Ventilatorsteuerung, 3-stufig Außen-/Fortluftklappe WRG-Bypassklappe Erhitzerventil Kühlventil (optional) TROX SCHOOLAIR Mechanical ventilation via decentralised ventilation units Classrooms frequently do not have mechanical ventilation. Insufficient ventilation not only causes mildew inside the rooms, but also results in poor concentration, headaches and illness, and this negatively influences the performance of pupils and teachers. TROX has developed the TROX SCHOOLAIR decentralised ventilation unit as a tailor-made solution for classroom refurbishments which is actuated and controlled via the Andover Continuum b3 867 BACnet controller. Use of EC radial fans guarantees energy efficiency and enables silent operation to avoid disturbing noise during lessons. Integrated heat recovery prevents unused heat in room air escaping to the outside. Fresh air flowing in is heated with heat exchangers during the winter months. Supply air can be utilised for free cooling via the heat recovery bypass. Combination of temperature control and air quality control The freely-programmable BACnet b3 867 single room controller in the Andover Continuum series manages actuation and control of the external air damper, the heat recovery bypass damper, the heater and, where applicable, the chiller, the fans (threestage) and measuring and processing of the supply air temperature. Connection of several air conditioning appliances and their BACnet controllers is realised via BACnet MS / TP. One controller functions as a master system with a connection to the STR504 room module. This measures the room temperature and actuates the operating mode via a push button. The specified room temperature set point can be raised or lowered by up to 5 K via a set point potentiometer. In addition to this, the master controller registers the external temperature via a sensor or, optionally, a network. A VOC sensor measuring the exhaust air indicates the air quality. Teaching, absence and stand-by times are defined by a scheduler, whereas the respective current mode can be overridden by the push button on the room module. Control during lessons The b3 867 controls both the room temperature and air quality during lessons on the basis of this standard configuration. Comfortable conditions can therefore be achieved with precision at those times when the room is occupied. Energy wastage outside these times is avoided by using the stand-by mode. A special control unit developed by Schneider Electric’s Buildings Business and connected directly via BACnet MS / TP ensures that the controllers always use the correct schedulers, even after a power cut. All b3 867 controllers can be operated centrally by connecting to a BACnet Building Controller (B-BC) which is equipped with a web server. Communication between the controllers is a mandatory requirement for the classification of the building in energy efficiency class A or B in compliance with EN 15232. The B-BC can be integrated into a BACnet management system via BACnet IP to enable centralised monitoring, alarming etc. Dezentrale Lüftungsregelung von Klassenzimmern über BACnet MS / TP. Decentralised ventilation of classrooms via BACnet MS / TP. Volker Barufke Marketing Schneider Electric Buildings Germany GmbH volker.barufke@buildings. schneider-electric.com www.schneider-electric. de / buildings Die Schneider Electric Buildings Germany GmbH mit Sitz in Oberhausen entstand aus der Verschmelzung der Unternehmen TAC GmbH und Messner Gebäude technik GmbH. Zu den BACnetProduktlinien des Unternehmens zählen Andover Continuum und miles. Based in Oberhausen, Schneider Electric Buildings Germany GmbH was created through the merger of TAC GmbH and Messner Gebäudetechnik GmbH. The company’s BACnet product lines include Andover Continuum and miles. BACnet Europe Journal 12 04/10 49 Anwendungen Solutions Vollintegration von Hocheffizienzpumpen – Kostenreduzierung und Energieeinsparung Full Integration of High-Efficiency Pumps – Cost Reduction and Energy Savings Der Allwetterzoo in Münster setzt bei der Sanierung der Aquariumsgebäude auf Energieeinsparungen durch umfassende Systemintegration mit dem Einsatz von BACnet. The all weather zoo in Munster relies on energy savings by means of extensive system integration with BACnet during renovation of the aquarium building. Für die Modernisierung der kompletten Heizungs- und Lüftungstechnik im Aquariumsgebäude des Allwetterzoos in Münster 2009, standen die Eckpunkte schnell fest: Möglichst hohe Energieersparnis durch den Einsatz moderner Regelung- und Anlagentechnik unter Schonung der Umwelt sowie Senkung der Betriebskosten. Die vollständige Einbindung in die vorhandene BOWS sowie WEBServer und Alarmmanagement war ohnehin obligatorisch. Hierbei sollten Einrichtungen wie die großen Aquarien oder die Kältemaschinen möglichst eingebunden werden um ein Maximum an Effizienz und Ersparnis zu erreichen. Der Systemintegrator SWG erarbeitete zusammen mit der technischen Leitung ein ganzheitliches Konzept für das gesamte Gebäude, dessen neuer Ansatz war, Heizungspumpen und Frequenzumformer zwecks besserer Regelbarkeit auf BACnet-Basis zu integrieren. Erstmalig wurden in diesem Projekt sämtliche Hocheffizienz-Heizungspumpen der Wilo-Stratos Baureihe auf Feldebene über BACnet MS/ TP intelligent eingebunden. Die Firma WILO SE entwickelte für ihre elektronischen Pumpen eine BACnet-Anbindung, die in enger Zusammenarbeit aller Beteiligten von der SWG im Gesamtkonzept eingesetzt wurde. Die Arbeiten wurden während des laufenden Betriebs durchgeführt. The work was carried out during normal operation. 50 BACnet Europe Journal 12 04/10 Kostenersparnis in der Bauphase Diese neue Technologie entwickelte bereits in der Bauphase echtes Einsparpotential. Durch die Anbindung über BACnet MS/TP entfielen neben den sonst üblichen Schaltausgängen zur Ansteuerung auch Eingänge für Betriebsund Störmeldungen. DDC und Schaltschrank wurden kleiner und damit kostengünstiger. Eigene Temperaturfühler der Pumpen ergaben hier weiteres Einsparpotential. Zusätzliche Fühler für Überwachung und Anzeige konnten weggelassen werden. Somit reduzierten sich die Kosten für die Verkabelung und die Feldgeräte. Eingänge auf der DDC waren ebenso wenig erforderlich wie das Einschweißen von Tauchhülsen an den Verteilern. Die intelligente Einbindung der Pumpen senkte bereits in der Bauphase die Kosten spürbar. Kostenersparnis im täglichen Betrieb Für die Regelung ergaben sich völlig neue Ansätze: Pumpen können nach Drehzahl, Massenstrom oder Druck geführt werden und liefern dabei ein differenziertes Bild der Betriebssituation. Somit ist es möglich, etwa den Differenzdruck in Abhängigkeit von Größen wie Außen- oder Raumtemperatur oder der Temperaturdifferenz zwischen Vor- und Rücklauf eines Heizkreises stetig zu optimieren und dadurch eine größtmögliche Energieersparnis zu erzielen. Zusätzliche Information für den Nutzer Mit über 40 BACnet Objekten liefert die BACnet-Schnittstelle von Wilo dem Nutzer eine Vielzahl an Informationen. So können auch Betriebsstundenzähler und Stromverbrauch abgelesen werden. Differenzierte Störmeldungen helfen in der Praxis Anlagenausfälle schon im Vorfeld zu vermeiden. Über Webzugriff konnte die SWG dem Zoopersonal die Möglichkeit geben sich auch aus der Ferne jederzeit ein klares Bild über die Betriebssituation zu verschaffen. Vollintegration auch in anderen Bereichen Bei der Lüftung wurde in gleicher Weise verfahren. Frequenzumformer und Registerpumpe wurden über BACnet MS/TP eingebunden. Dabei ergaben sich bei den Umformern die gleichen Vorzüge wie bei den Pumpen: Reduktion der Hardware, optimierte Regelbarkeit und ein Plus an Information. Bei der Erfassung des Energieverbrauchs wurden Zähler mit integrierter BACnet Schnittstelle eingesetzt. Neben den reinen Verbrauchsdaten stehen damit auch Details wie Strom, Spannung oder Lei- Anwendungen Solutions Über BACnet eingebundene Hocheffizienz-Heizungspumpen. High-efficiency heating pumps integrated via BACnet. stungsfaktor zur Verfügung und geben dem Betreiber zusätzliche Informationen zur Analyse seines Energieverbrauches an die Hand. Die autark arbeitende Temperierung aller großen Fischbecken wurde über BACnet eingebunden und in das bestehende Störmeldesystem integriert, ebenso, wie die Regelung der Kleinkälteanlagen. Fazit Durch die von der SWG erstmalig durchgeführte Vollintegration aller wichtigen Bereiche der Betriebstechnik eines Gebäudes konnte hier ein ganzheitliches Konzept mit absoluter Konsequenz umgesetzt werden. Neben der Kostenersparnis während der Bauphase und im täglichen Betrieb des Gebäudes zählen das Plus an Information und Regelbarkeit zu den Highlights. Der Anspruch an einen umweltfreundlichen und resourcenschonenden Betrieb wurde in vollem Maße umgesetzt. Mit der Einbindung von Pumpen und Frequenzumformern über das normierte BACnet-Protokoll wurde ein weiterer wichtiger Schritt hin zum ganzheitlich optimierten Gebäude gemacht. The key points for the renovation of the entire heating and ventilation technology in the aquarium building of the Allwetterzoo in Mun- ster were quickly determined: High energy savings should be achieved by using stateof-the-art control and system technology which protects the environment and reduces operating costs. The complete integration into the existing BOWS as well as the web server and alarm management was mandatory. Facilities such as the large aquariums or the refrigerating machines had to be integrated in order to achieve maximum efficiency and savings. The system integrator SWG worked out an integral concept for the entire building in cooperation with the technical management. Their new approach was to integrate heating pumps and frequency converters for better control on the basis of BACnet. For the first time, all high-efficiency heating pumps of the WILO-Stratos series were integrated on field level via BACnet MS / TP. The company WILO SE developed a BACnet connection for its electronic pumps which was applied in the overall concept in close co-operation of all participants of SWG. Cost savings in the construction phase This new technology developed a real savings potential already in the construction phase. Due to the connection via BACnet MS / TP, the usu- al switching outputs for control and the inputs for operating and fault signals were not required anymore. The DDC and the switch cabinet were smaller and thus more cost-effective. The pumps’ own temperature sensors brought about another savings potential. Additional sensors for monitoring and display could be omitted. So costs for wiring and field devices could be reduced. Neither inputs on the DDC nor welding the immersion wells at the distributors were required. The intelligent integration of the pumps reduced the costs in the construction phase considerably. Cost savings in daily operation Completely new approaches arose for control: Pumps can be controlled according to speed, mass flow or pressure so that a differentiated impression of the operating situation is given. For example, it is possible to continuously optimise the differential pressure depending on parameters like the outdoor or indoor temperature or the temperature difference between the feed and the return of a heating circuit, thus achieving the best possible energy savings. Additional information for the user With more than 40 BACnet objects, the BACnet interface from Wilo offers users a lot of information. So also the operating hours counter and the electricity consumption can be read. Differentiated fault signals help to prevent system breakdowns before they can occur. SWG offered the zoo staff the opportunity to get a clear impression of the operating situation anytime from a distance via web access. Full integration as well in other areas The same method was applied for ventilation. Frequency converters and the register pump were integrated via BACnet MS / TP. In doing so, there were the same advantages for the fre- quency converters as well as for the pumps, such as the reduction of the hardware, required optimised controllability and more information. Counters with an integrated BACnet interface were applied for calculating the energy consumption. Besides the mere consumption data, details like the current, voltage or the performance factor are available and give the operator additional information for analysing his energy consumption. The autarkic temperature control of all large fish tanks was connected via BACnet and integrated into the existing fault signal system. The control of small refrigerating machines was also integrated. Due to the full integration of all important areas of the building’s technology carried out by SWG for the first time, an integral concept could be realised in an absolutely consistent. The highlights are the additional information and controllability – besides the cost savings during the construction phase and in the building’s daily operation. The requirements for an environmentally sound and resource saving operation were completely realised. The integration of pumps and frequency converters via the standardised BACnet protocol is another step towards a completely optimised building. Sascha Stuckmann SWG Stuckmann Wirtschaftliche Gebäudesysteme GmbH [email protected] www.swg-beckum.de BACnet Europe Journal 12 04/10 51 BACnet insight BACnet Objekte und Funktionen zum Energiesparen BACnet Objects and Functions for Energy Saving Frank Schubert1 Als offenes Kommunikationsprotokoll wurde BACnet in Bezug auf die zu übertragenden Informationen so flexibel gestaltet, dass sich diese aus vielfältigen Anwendungen abbilden lassen. Die Informationen werden im BACnetStandard in Form von Objekten bereitgestellt, deren Elemente verschiedene Informationseigenschaften transportieren (den Wert selbst, Beschreibungstexte, Einheiten, Grenzwerte, usw.). Auch wenn ein Datenprotokoll nicht selbst Energie sparen kann, so bildet die offene Kommunikation mit BACnet jedoch die Basis dafür, dass Geräte ihre Daten für Anwendungen zum Energiesparen austauschen können, dies auch mit Komponenten verschiedener Hersteller in einem homogenen Verbund. In den vergangenen Teilen der Insight-Reihe wurden bereits viele Objekte in Bezug auf ihre Anwendung im Detail vorgestellt. Dieses Mal werden die für Energieeinsparung sinnvoll einsetzbaren Objekte und Funktionen im Überblick vorgestellt. Abbildung realer und virtueller Größen Für die Abbildung realer Messgrößen und Vorgabewerte sowie für berechnete, also virtuelle Informationen stellt BACnet insgesamt neun Standardobjekte bereit, jeweils unterteilt in Input (= phys. Eingangswert), Output (=phys. Ausgangswert) und Value (=berechneter Wert) für Analogwerte, Binärwerte und mehr- stufige Werte. Funktionen wie Betriebsstundenzählung oder minimale Einschalt- / Ausschaltzeiten sind als Option ebenfalls mit diesen Objekten möglich. Abbildung von Zählern Für die Abbildung von Zählern bietet BACnet zwei Objekte an. Das Accumulator-Objekt ermöglicht die Abbildung gezählter Impulse und liefert hiermit die Rohdaten. Das Pulse-Converter Objekt kann auf Basis gezählter Impulse entweder aus einem angeschlossenen Accumulator oder einer internen Quelle die Werte in einer fertig berechneten Einheit, z.B. kWh oder Megajoule, usw. bereitstellen. Insbesondere für die Abbildung des Energieverbrauchs oder aktueller Energiemengen sind diese Objekte in Bezug auf Energiesparfunktionen wichtig. Abbildung von Regelprozessen Das Loop-Objekt bietet die Abbildung von PID-Regelkreisen an. Dabei sind Regelparameter bereits Eigenschaften (Properties) des Objektes selbst und müssen daher nicht separat über weitere Objekte abgebildet werden. Loop-Objekte können (je nach Anwendung) auch als Kaskade ausgeführt werden, so dass der Ausgangswert einer Kaskade den Eingangswert der nächsten Kaskade bildet. Abbildung von Log-Speichern Für die Abbildung von Langzeitspeichern bietet BACnet die Objekte Trendlog (genau 1 Speicher für Trenddaten) oder Trendlog- Frank Schubert, MBS GmbH, ist Mitglied des Advisory Board und der Arbeitsgruppe Technik der BIG-EU sowie als Schulungsleiter der BACnet Interest Group Europe aktiv, [email protected]. Frank Schubert, MBS GmbH, is member of the Advisory Board and Working Group Technique of the BIG-EU as well as training-leader of the BACnet Interest Group Europe, [email protected]. 1 52 BACnet Europe Journal 12 04/10 Multiple (mehrere Trendspeicher z.B. zur parallelen Aufzeichnung). Die Trendlog-Objekte können mit Alarmfunktionen ausgerüstet sein, um ein bevorstehendes Überschreiben des Speichers an ein übergeordnetes System zu melden. Abbildung von Zeitschaltfunktionen Für die Abbildung von Zeitschaltfunktionen stellt BACnet das Calendar-Objekt (=Betriebskalender, enthält Datumsangaben, die mit dem aktuellen Datum verglichen werden) und Schedule (=Zeitschaltplan mit Wochenoder Ausnahmedefinitionen) bereit. Hiermit sind zeitabhängige Vorgänge steuerbar (z.B. Minimalprogramm in den Ferien). Abbildung von Anlagen-Hierarchien Während das Group-Objekt (=Objektgruppe in einem einzelnen Gerät) bzw. das Global Group-Objekt (=netzwerkweite Gruppe) angeschlossene Objekte ohne spezielle Hierarchie abbildet, bietet das Structured ViewObjekt die Möglichkeit, eine Anlagenstruktur als hierarchische Übersicht abzubilden. Die Zuordnung der Verbrauchswerte zu den lokalen Liegenschaftsbereichen kann z.B. für Abrechnungszwecke interessant sein. Abbildung von GA-Funktionen Das Command-Objekt erlaubt die Abbildung von zentralen Kommandos, also das Setzen von Szenen wie z.B. Nachtbetrieb (die einzelnen Aktionen sind im Command-Objekt hinterlegt). Das Program-Objekt erlaubt den Zugriff auf das Anwendungsprogramm eines BACnet-Controllers, so dass zum Beispiel zwischen verschiedenen Programmen umgeschaltet werden könnte (Normalprogramm, Sparprogramm). Das Load-Control-Objekt erlaubt direkten Eingriff in die Anlage für Energiesparmaß- nahmen durch aktive Maximumbegrenzung (z.B. E-Max). Dabei werden die Überwachungsparameter und die Abschaltfunktionen direkt im Objekt hinterlegt. Ausblick auf weitere Objekte Für andere Gebäudebereiche wurden weitere Objekte spezifiziert, die ebenfalls in Bezug auf Energieeinsparungen wichtig werden könnten. Das Lighting-Objekt erlaubt die Abbildung von Beleuchtungseinrichtungen und stellt u.a. Dimmerfunktionen bereit, die zur Energieeinsparung beitragen können. Transport von Wertänderungen mit COV Neben der Abbildung der Daten spielt auch die Benachrichtigung der aktuellen Werte und Betriebszustände bei Energieeffizienzmaßnahmen eine zentrale Rolle. Hierzu stellt BACnet Methoden zur Übertragung von Wertänderungen (COV=Changeof-Value) bereit. Dabei werden übergeordnete Systeme automatisch benachrichtigt, wenn sich Messwerte oder Zustände geändert haben, so dass sich hiermit übergeordnete Aufzeichnungsund Analysefunktionen realisieren lassen. Alarme und Ereignisse BACnet stellt zwei Methoden zur Erkennung von Ereignissen und Alarmen bereit. Bei der einfachen Grenzwertüberwachung (Intrinsic Reporting = „aus dem Inneren des Objekts“) wird der aktuelle Wert auf Grenzwerte (analog) bzw. auf einen bestimmten Zustand / Zustände (binär oder mehrstufig) überwacht und im Falle eines nicht normalen Zustands als Alarm / E reignis gemeldet. Für die Überwachung weiterer Eigenschaften verwendet BACnet das Event-Enrollment-Objekt, wobei hier insgesamt neun verschiedene Algorithmen die Art BACnet insight der Grenzwertüberwachung definieren. Für Energieoptimierungen ist insbesondere das Verfahren „Floating_Limit“ (=gleitende Grenzwerte) interessant. Hiermit werden die Grenzwerte z.B. außentemperaturgeführt anhand der tatsächlichen Umgebungsparameter nachgeführt und erlauben gegenüber einer statischen Festlegung eine optimierte Überwachung. Gehende Alarme (TO_NORMAL) oder Fehlerzustände (TO_ FAULT) werden bei der Alarmverarbeitung in BACnet ebenfalls automatisch gemeldet. Fazit Insgesamt lässt sich zusammenfassen, dass BACnet alleine zwar keine Energie einspart, jedoch durch die vielfältigen Möglichkeiten bestens für die Abbildung der Energiedatenerfassung, Energieanalysen bis hin zu aktiven Energiesparfunktionen geeignet ist. BACnet as an open communication protocol was designed so flexible to fit the requirements of a wide range of applications. The information transported with BACnet are organized in socalled objects, which present the information as properties of the object (e.g. the Present-Value, Description, Units, Limits, etc.). Even if a communication protocol itself (a “language”) cannot save energy, BACnet with its open and flexible platform offers the basis to exchange data between energyefficiency applications, also connecting different vendors to a homogenous network. In the past issues of this Insight articles a lot of objects according to specific applications have been already introduced in detail (e.g. Trend-logging, Scheduling). This Insight article explains why ap- plications for energy-savings perfectly fit into the BACnet objects and services. Presenting physical and virtual data To exchange measurements and set-points as well as calculated (virtual) information BACnet specifies a total of 9 standard object types, each for inputs, outputs and values for Analog-, Binary- and Multi-State-Data. Functions like counting the elapsed active time or minimum-on / off handling are available as an option in these objects, too. Presenting counter values To present counters BACnet introduces two object types. The Accumulator-Object allows representation of raw impulse counting, while the Pulse-Converter Object takes the impulses from an Accumulator or an internal source and converts it into a calculated engineering unit like kiloWatt-hours or Mega-Joules. Especially to count the energy-consumption these two objects are important for energy-savings. Representing control loops The Loop-Object offers representation of PID-control loops, while the control parameters are properties of the object and do not necessarily need to be presented by additional objects. Depending on the application loop objects may be cascaded by connecting the output value of a cascade to the input of the successor. Representing log-information To provide access to log-buffers for long-term data-acquisition BACnet offers the Trendlog-Object (exactly 1 Buffer to store data from a single source) and the Trendlog-Multiple object offering multi-channel acquisition and representation of trendlog-data. Trendlog-objects can be protected from losing collected data by issuing alarms, if the number of records in the buffer exceeds a certain threshold. Representing schedule functions For scheduling purposes BACnet specifies the Calendar-Object (a list of data-values compared with the current date) and the Schedule-Object providing the schedule program either as a weekly or an exception schedule) With this it is possible to realize time- or datebased functions (e.g. a special holiday operation). Representing facility hierarchies While the Group-Object (=group of objects within a single device) and the Global Group-Object (=network-wide object group) simply represent objects without any specific hierarchy the Structured-ViewObject allows you to represent the objects as a facility hierarchy. This can be necessary in facility management e.g. for commercial purposes. Representing building automation functions The Command-Object allows representation of commands, e.g. night operation, where the command-object contains the single actions of each command. The program object allows access to the application program of a BACnet controller, so that e.g. switching between normal and energy-savings programs becomes available to the user. The Load-Control-Object is designed to actively provide energysavings by maximum load control (e.g. E-Max). The parameters to be observed and the actions to temporarily shutdown components are stored within the object as properties. Outlook to other objects For other areas in buildings BACnet specifies a various number of additional objects that have relationships to energy-savings. The Lighting-Object allows representation of lighting systems and offers functions like dimming, which may be used for energy-savings as well. Transporting value-changes Besides the data representation the notification if values change plays a major role in energy-efficiency. For this BACnet provides the COV (Change-of-Value) services to automatically notify valuechanges for logging and analysis purposes. Alarms and events BACnet offers two methods for alarm and event detection. Intrinsic Reporting compares the present value against the limits (analog data) or alarm values (binary or multi-state data) and generates alarms or events in case of non-normal states To observe other properties eventenrollment can be used in BACnet to provide a total of 9 algorithms for alarm detection. For energy savings especially the Floating-Limit algorithms is of interest. With this e.g. the limits can be controlled in relation to the outside temperature and allow optimized observation compared to static limit definition. Return to normal alarms or fault values are notified by the alarm handling of BACnet controllers as well. Conclusion Putting everything together, BACnet itself does not save energy directly but the various options of this international standard allow representation of all aspects in energy management including presenting the data, energy analysis up to active energy optimization. BACnet Europe Journal 12 04/10 53 BACnet insight Bessere Qualität von BACnet Projekten II Higher Quality from BACnet Projects II Dr. Uwe Haeseler1 Arien Peterse2 Betreiber von BACnet basierten Gebäudeautomationssystemen sind oft unzufrieden, da ihre Erwartungen an das System nicht vollständig erfüllt werden. Hierfür gibt es verschiedene Ursachen: Die Planung fordert zwar viele Eigenschaften von BACnet Geräten mit einer endlosen Liste von Properties und BIBBs, nicht jedoch was als Aufgabe der Gebäudeautomation realisiert werden soll (Leistungen). Die Planung fordert pauschal „ein Stück BACnet“ Ein Auftragnehmer (AN) führt nur aus, wozu er glaubt, vom Auftraggeber (AG) beauftragt zu sein, ohne das gesamte System aus Automationsstation (AS) und B-OWS zu berücksichtigen. Bei BACnet-Systemen ist eine Dezentralisierung von Aufgaben (z.B. Alarmgenerierung, Zeitpläne, Trends) üblich. In Ausschreibungen erfolgt die Trennung von Aufgaben der Gebäudeautomation in der Automationsstation unzureichend von den in der B-OWS angesiedelten Aufgaben. Der Abdruck von Kapitel eins und drei zum Thema „bessere Qualität von BACnet Projekten“ erfolgte in Ausgabe 11 des BACnet Europe Journals. Der Artikel ist online verfügbar unter www. bacnetjournal.org BACnet – Automationsstation 2.1. Grundlagen 2.1.1 Installation Pro Informationsschwerpunkt (ISP) soll als Automationsstation mindestens ein über BACnet / I P angeschlossener B-BC installiert werden. Weitere Geräte können entsprechend ihren Aufgaben auch andere BACnet Profile repräsentieren oder über BACnet MS / T P angeschlossen werden, wobei dies zu keiner Einschränkung der Eigenschaften/ L eistungen bezüglich des ISP insgesamt führen darf. BACnet MS / T P wird als Feldbus vorgeschrieben, proprietäre Feldbusprotokolle sind nur in vorab genehmigten Ausnahmen zulässig. Zwingend vorgeschrieben ist die Einbindung von Frequenzumrichtern und Raumregelern per BACnet MS / T P oder BACnet / I P 2.1.2 Datenpunkte und Objekte Physikalische Eingänge werden direkt als je ein BACnet Input Objekt dargestellt. (Binary_Input, Analog_Input, Multistate_ Input) Physikalische Ausgänge werden direkt als je ein BACnet Output Objekt dargestellt. (Binary_Output, Analog_Output, Multistate_ Output). Eingänge und Ausgänge werden in ihren natürlichen Einheiten dargestellt. Es sind keine zusätzliche BACnet Objekte für Zwischenberechnungen (Bit, Spannungen von aktiven Fühlern, ...) zulässig. 2.1.3 Verhalten mit BACnetClients Änderungen durch eine beliebige B-OWS (Sollwerte, dynamisch erzeugte Objekte usw.) müssen nach Operationen mit dem AS-Engineering Tool (z.B. Programmänderungen, Neuladen der AS…) bestehen bleiben. Das Setzen / Rücksetzen eines BACnet Input Objekts auf „Out_ Of_Service“ muss dazu führen: dass der über die B-OWS gesetzte Present_Value anstelle des Messwertes in der jeweiligen Applikation (Regelung, Steuerung, Alarme…) verwendet wird. dass der Present_Value nach dem Zurücksetzen automatisch und sofort den aktuellen Messwert hat. Die AS unterstützt das dynamische Erzeugen / L öschen von Objekten mit einer beliebigen BOWS, dies insbesondere für das Anlegen von Trends mit der BOWS. 54 BACnet Europe Journal 12 04/10 Alle Output Objekte verfügen über das Priority_Array und lassen sich durch eine beliebige B-OWS mit jeder beliebigen Priorität übersteuern. 2.1.4 Datenaustausch Alle frei programmierbaren AS unterstützen COV zum Datenaustausch zwischen AS untereinander und zu B-OWS. 2.1.5 Alarmmanagement Das Alarmmanagement kann sowohl mit Intrinsic Reporting als auch mit Algorithmic Reporting gelöst werden. Die AS muss Änderungen der RecipientList sowohl mit den Diensten „WriteProperty“ als auch „AddListElement“ ermöglichen. Die AS muss Einträge in die RecipientList sowohl als DeviveID als auch als MAC-ID ermöglichen, der Eintrag als Device-ID ist vorzuziehen. 2.1.6 Zeitpläne Es sind mindestens 8 Schaltzeiten (Ein / Aus) pro Tag möglich, die über die OWS einstellbar sind. Die AS muss in Zeitplänen unterschiedliche Typen unterstützen: Binary Analog Multistate Die AS muss in Zeitplänen Sondertage auf eine der folgenden Arten handeln können: mit Calendar Objekt mit direktem Sondertag-Eintrag im Schedule Objekt 2.1.7 Trends Das dynamische Erzeugen / L öschen von Trend_Log‘s mit einer beliebigen B-OWS in der AS ist möglich. 2.2. Enthaltene Leistungen 2.2.1 Allgemeines Die beschriebenen Leistungen sind mit einzukalkulieren. Ebenso die Erstellung und Parametrierung aller notwendigen internen BACnetObjekte und Datenpunkte. 2.2.2 Adressierung / Objekt namen / Texte Als Datenpunktadresse wird der Objektname verwendet. Es kann entsprechend Hersteller / Systemintegrator mit folgenden Einschränkungen frei gewählt werden: die Festlegungen des BACnet Standards werden eingehalten Das erste Zeichen ist ein Buchstabe Die weiteren Zeichen sind alphanumerische Zeichen, als einziges Sonderzeichen ist der Unterstrich (’_’) zulässig. Als Benutzeradresse wird das property „Description“ verwendet. Das Property Description ist vollständig einzurichten. Verwendet werden soll der vorgegebene Schlüssel zur Bezeichnung von Datenpunkten (Teil 1) gefolgt von einem beschreibenden Klartext (Teil 2), in welchem die Anlage, Baugruppe, Funktion und Datenpunktart als Klartext enthalten ist. Der eingerichtete Schlüssel und die Klartexte sind mit dem Auftraggeber abzustimmen. Alle Objektnamen und Properties Description von komplexeren Objekten wie Trend_Log, Notification_Class, Event_Enrollment, Schedule usw. sind entsprechend den zugehörigen Objekten und entsprechend der Datenpunktadresse und Benutzeradresse zu vergeben und mit dem AG abzustimmen. In Text-Properties (Objektname, Description, Inactive / Active Text…) sind nur Zeichen entsprechend der von der B-OWS unterstützten Zeichensätze zulässig, auch wenn die AS mehr oder andere Zeichensätze unterstützt als die B-OWS. Das Property „Location“ wird vollständig eingerichtet, sofern es bei entsprechendem Gerät unterstützt wird. Alle Einheiten für Analog Objekte werden vollständig eingerichtet. BACnet insight Alle Zustandstexte für Binary und Multistate Objekte werden projektweit einheitlich und vollständig eingerichtet. Die Steuerung in der Automationsstation muss vollständig engineert werden, so dass keine zusätzliches Engineering auf der Managementebene (BACnet Client) notwendig ist. 2.2.3 Datenaustausch Alle wesentlichen Parameter wie Sollwerte, Grenzwerte für Schaltungen, gleitende Sollwertberechnung, Grenzwerte für Alarme usw. sind als BACnet Objekte bzw. Properties bereitzustellen und sollen mit einem beliebigen BACnet-Client veränderbar sein. Dokumentiert werden muss: die Wirkungsweise der Steuerung und Regelung die Kommunkation zwischen den AS 2.2.4 Alarmmanagement Mindestens 3 Alarm-Klassen müssen eingerichtet werden. (z.B. Wartung, Störung, Gefahr). Alarme sind einzurichten für: Jede technologische Störung Jede Sollwertabweichung bei aktiver Regelung Sensorausfall Überwachung Schaltung / B etriebsmeldung Schaltung an Hand- / Notbedienebene Für jeden Alarm ist eine Meldeschauerunterdrückung einzurichten. Die Quittierung eines Alarms ist unabhängig von der Entriegelung von Störungen am Schaltschrank einzurichten. Die Alarme werden so eingerichtet, dass die Quittierung in der AS gespeichert wird. Die Alarme werden so eingerichtet, dass die AS im Fall eines Alarmes zusammen mit der Alarmmeldung einen Message_ Text schickt. 2.2.5 Zeitpläne Zeitschaltungen werden in der AS mit Schedule ausgeführt und mit der B-OWS lediglich bedient: B-BC, B-AAC: internal B-ASC, B-AS, B-SS: übergeordnete AS (external) Die Zeitpläne werden entsprechend den technologischen An- forderungen vollständig in den AS eingerichtet. Zeitpläne sind für Betriebszeiten von Anlagen einzurichten, nicht für kurzzeitige Schaltungen wie Wartungslauf für Pumpen o.ä. Operators of BACnet-based building automation systems are often dissatisfied because their expectations of the system are not met. There are several reasons: 2.2.6 Trends Für jeden eingerichteten Regelkreis werden nachfolgende Trend_Log Objekte angelegt (der Objektname / Description orientiert sich an den jeweiligen Datenpunkten): Messwert Sollwert Stellgröße tensive requirementsof BACnet devices with an endless list of properties and BIBBSs, but failed to describe the actual operational requirements of the building automation system (performance) The specificiation simply stated „it must be BACnet“. The „contracted supplier“ (CS) only delivered what they interpreted in the contract issued by the „contracted client“ (CC), without taking the complete system comprising the automation stations and the B-OWS. The various tasks such as alarm generation, time schedules, trends etc. are typicall decentralized in BACnet systems. Instead, the specification failed to clearly sperate the tasks to be performed in the automation stations from the tasks to be performed at the B-OWS level. Alle DDC-Schaltungen und Betriebsrückmeldungen werden projektweit einheitlich mit Trendlog Objekten archiviert (Ereignisorientierte Aufzeichnung, zyklische Aufzeichnung ist nicht zulässig). 2.2.7 Regelungen / Steuerungen Für Regelungen ist zwingend das BACnet Objekt „Loop_Object“ zu verwenden, die Reglerparameter müssen mit einer beliebigen BOWS einstellbar sein. 2.2.8 Dokumentation Zur Dokumentation der BACnet Objekte wird ein EDE-File durch den AN zur Verfügung gestellt, welches zur Dokumentation dient. Das EDE-File ist mit folgenden Bedingungen zu erstellen: Die Spalte „keyname“ entspricht inhaltlich der Spalte „object-name“ alle mit „optional“ gekennzeichneten Spalten werden ausgefüllt, sofern das jeweilige Objekt die entsprechenden properties unterstützt auf jeden Fall müssen die Spalten „vendor-specific-address“ und „settable“ (früher „commandable“) ausgefüllt werden. Es sind sämtliche im Gerät enthaltenen Objekte aufzulisten, auch die komplexeren Objekte wie Trend_Log, Notification_Class, Event_Enrollment, Schedule usw. The specification laid out ex- The imprint of chapter one and three for the theme of “better quality of BACnet projects” carries out in Issue 11 of the BACnet Europe Journal. The article is available online at www.bacnetjournal.org BACnet – Automation Station 2.1 Basic Requirements 2.1.1. Installation The Automation Station (AS) for each mechanical / electrical plantroom (MEP) location is to be installed with a mimium of one BBC connected via BACnet / IP. Additional devices may conform to a different BACnet profile to suit the required functionality and / or may be connected via BACnet MS / TP. However the performance and characteristcs of the associated plant operation must not in any way be limited in this case. BACnet MS / TP shall be utilized at the field bus level. Proprietary field bus protocols may only be utilized when approved prior to the tender. It is a strict requirement for variable speed drives and room controllers to be conncted via BACnet MS / TP or BACnet / IP. 2.1.2 Datapoints and Objects Physical inputs shall in each case be represented by a BACnet Input Object (Binary_Input, Analog_Input, Multistate_Input). Physical outputs shall in each case each be represented by a BACnet Output Object (Binary_Output, Analog_Output, Multistate_Output). Inputs and outputs shall be displayed with their natural units of measurement / status. Additional BACnet objects for intermediary calculations (bit transformation, ranges of active sensors,...) shall not be accepted. 2.1.3 Interaction with BACnet Clients Settings and adjustments from a BACnet client (setpoints, dynamically created objects, etc.) shall remain in effect after any operation is peformed with the AS engineering tool (e.g. program changes, reloading the AS...). Setting / resetting a BACnet Input Object to / from “Out of Service”shall result in: the Present_Value set by the B-OWS taking effect within the respective application (control loop, operation sequence, alarming...), instead of the measured / monitored value. the Present Value being assigned to the measured / monitored value immiediately and automatically when reset back from “Out of Service”. The AS shall support the dynamic creation / deletion of objects from any given B-OWS, particularly with regard to the setting up Trends from a B-OWS. All Output Objects shall operate in accordance with the Priority Array and may be overridden from any given B-OWS with any appropriate priority as required. 2.1.4 Data Exchange Each free-progammable AS shall support COV for data exhange with other AS as well as with the B-OWS. 2.1.5 Alarm Management Alarm management can be triggered by Intrinsic Reporting as well as by Algorthmic Reporting mechanisms. The AS shall allow changes to the Recipient List using the “Write Property” service as well as using the “AddListElement” service. BACnet Europe Journal 12 04/10 55 BACnet insight The AS shall allow Device ID entries as well as MAC-ID entries to be made in the “Recipient List”; the entry with Device ID shall take precendence. 2.1.6 Time Schedules A minimum of 8 switch times (On / Off) shall be possible for any gven day, and shall be definable by the B-OWS. The AS shall support various object types: Binary Analog Multistate The AS shall be able to handle exceptions to standard time schedules in one of the following ways: Calendar Object Exception days to be entered directly in the Schedule Object 2.1.7 Trends It shall be possible to create / delete Trends_Log in the AS from any given B-OWS. 2.2 Deliverables 2.2.2 General The described performance scope shall be allowed for in the tender price, including the generation and configuration of all internal BACnet objects and datapoints. 2.2.3 Addressing / Object Names / Descriptions The Object Name shall be used to represent the datapoint address. It can be freely defined as necessary by the Manufacturer / System Integrator, but with the following restrictions: it shall fall within definition of the Bacnet standard the first character shall be a letter the subsequent characters shall be alphnumeric, where under- score (“_”) is allowed as the only special character The “Description” property shall be used to represent the user address. The Description property syntax shall be structured in a comprehensive format. A key shall be provided to define the Datapoint (part 1), followed by the full text description (Part 2), which clearly identifies the system, equipment, function and datapoint type in expanded text. The key format and text descriptions are to be agreed upon with the Contracted Client. All Object Names and Description properties of more complex objects such as Trend_Log, Notification_Class, Event_Enrollment, Schedule, etc. shall be defined according to their respective datapoint- and user-addresses, and are to agreed upon with the Contracted Client. Only characters supported in the B-OWS character set shall be used for text-based properties (Object Name, Description, Inactive / Active Text...), even if the AS is able to support more or different characters than the B-OWS. The “Location” property shall be fully implemented in the event that it is supported by the respective device. All units for Analog Objects shall be fully implemented. ther engineering is required at the management level (BACnet client). 2.2.4 Data Exchange All required parameters for setpoints, switching limits, sliding setpoint schedules, alarm limts etc. shall be provided by BACnet Object Properties and can be adjusted by any given B-OWS The following shall be documented: the sequence of operation data exchange between AS’s 2.2.5 Alarm Management A minimum of three Alarm / Event Classes shall be defined (e.g. Maintenance, Fault, Alarm). Alarm / Events shall be utilized for each: technical fault setpoint deviation in active control loops sensor failure monitored operational status manual / emergency override It shall be possible to suppress any given Alarm / Event. The acknowledgement of Alarm / Events shall be independent of the fault being rectified at control panel. Alarm / Events shall be defined such that their respective acknowledgements actions are stored in the AS. All status texts for Binary and Multistate objects shall be fully implemented on a consistent basis for the entire project. Alarm / Events shall be defined such that in the case of any Alarm / Event occuring, the AS will send the notification of the Alarm / Event together with a Message_Text. The operation of the AS shall be fully engineered so that no fur- 2.2.6 Time Schedules Timed operation shall be execut- Dr. Uwe Haeseler ist Leiter Gebäudeautomation der Cofely Deutschland GmbH (NL Berlin) und Mitglied der Arbeitsgruppe Technik der BIG-EU, uwe. [email protected]. Dr. Uwe Haeseler is Director of Building Automation of Cofely Deutschland GmbH and member of the working group technique of the BIG-EU, [email protected] 1 Arien Peterse, Regel Partners B.V., ist Mitglied der Arbeitsgruppe Technik der BIG-EU. [email protected]. Arien Peterse, Regel Partners B.V., is member of the working group technique of the BIG-EU, a.peterse@ regelpartners.nl. 2 56 BACnet Europe Journal 12 04/10 ed with the Schedule Object and shall be user-defined from the B-OWS: B-BC, B-AAC: internal Schedule B-ASC, B-AS, B-SS: higher level AS (external Schedule) Time Schedules shall be utilized in the AS to fully meet all operational requirements. Time Schedules shall be utilitized to accomodate the equipment and system operating hours, and not for short period operation such as pump maintenance cycles. 2.2.7 Trends Trend_Log Objects shall be utilized for each control loop (the object Name / Description shall be oriented to the respective datapoint): Measured Value Setpoint Control Value All DDC switched outputs and status feedbacks shall be archived with Trend_Log objects on a consistent basis for the entire project. 2.2.8 Control Loops The BACNet “Loop” Object shall be utilized for all control loops, whereby the respective control loop parameters shall be user definable from any given B-OWS. 2.2.9 Documentation The BACnet objects shall be documented within an EDE-file, which is to be provided as part of the overall documentation set by the Contracted Supplier. The EDE-file shall be created in accordance with the following criteria: The content of the “keyname” field shall be the same as the “object-name” field All fields designated as “optional” shall contain entries whenever the respective Object properties are supported The “Vendor-specific-address” and “settable” columns must contain entries in all cases The various objects in the device shall also be itemized, included more complex objects such as Trend_Log, Notification_Class, Event_Enrollment, Schedule, etc. Produkte Products WRF08 BACnet – Komfortable Raum bedienung im ansprechenden Design Comfortable Room Control Highly Design-Oriented Die Thermokon-Produktreihe der Raumbediengeräte begrüßt ein bekanntes Gesicht mit neuer Basis. Ab sofort ist das WRF08_BACnet-MS / TP zur komfortablen Bedienung einer BACnet-orientierten Automationsumgebung erhältlich. Thermokon’s proven and well-known product line of multifunctional room operating panels series WRF08 is extended by a BACnet compatible type. Now the WRF08_ BACnet_MS / TP is available for convenient operation of BACnet oriented automation environments. Das große LC-Display zeigt standardmäßig die gegenwärtige Raumtemperatur an, welche über einen integrierten Temperatursensor ermittelt wird. Spezifische Anzeigen können problemlos über das mitgelieferte Konfigurationstool realisiert werden. übertragung RS-485. Das Gerät arbeitet mit dem Geräteprofil BACnet Application Specific Controller (B-ASC). Sämtliche integrierten BACnet-Objekte sowie die Dokumentation der BIBBS sind auf der Thermokon-Homepage einsehbar. As a standard, the large LCdisplay shows the actual room temperature detected by an integrated temperature sensor. Customized settings can be easily realized by means of the supplied configuration tool. With up to 12 operating buttons, the WRF08 BACnet is Das WRF08 auf BACnet-Basis fokussiert mit der Option von bis zu 12 Bedientasten die Anwendungen in ihrem individuellen Einsatzbereich. Durch die großzügige Designvielfalt, realisiert durch unterschiedliche Grundfarben des Gerätes sowie verschiedenste Designrahmen, lässt sich das WRF08 als Blickfang in eine Designkonzeption integrieren. Enabled connection to remote stations The use of the standardized BACnet MS / TP protocol enables the connection to corresponding remote stations such as additional automation systems or control technologies like the BACnet Operating Workstations. The interface standard RS485 is used for digital data transmission. The room panel operates with the device profile BACnet Application Specific Controller (B-ASC). All integrated BACnet objects as well as the BIBBS documentation can be viewed at Thermokon’s website. Anschluss an Automationsstationen oder Leittechniken Die Verwendung des standardisierten BACnet MS / T P Protokolls ermöglicht den Anschluss an entsprechende Gegenstellen wie zusätzliche Automationsstationen oder Leittechniken wie BACnet Operating Workstations. Als Schnittstellenstandard dient die digitale Daten focused on your individual applications. Thanks to a great design variety realized by different basic colors for the device as well as various design frames, the WRF08 can be ideally integrated in your design concepts as an eyecatcher. Das Raumbediengeräte WRF08_BACnet-MS / TP von Thermokon. The WRF08_MS / TP – convenient room control. 58 BACnet Europe Journal 12 04/10 THERMOKON Sensortechnik GmbH www.thermokon.de [email protected] Produkte Products Der SRC65-BACnet fungiert als Gateway zwischen der drahtlosen EnOcean-Technologie und BACnet. The SRC65-BACnet act as a gateway between the wireless EnOcean-technology and BACnet. Technische Symbiose in der Gebäudeautomation Technical Symbiosis in Building Automation Warum nur eine der zahlreichen Netzwerktechnologien in der Gebäudeautomation nutzen? Thermokon kombiniert mit dem neuen BACnet-EnOcean-Gateway SRC65-BACnet zwei etablierte Netzwerktechnologien, um energieeffiziente und umweltfreundliche „Green Buildings“ zu ermöglichen. Why use only one of the numerous network technologies in building automation? By means of the new BACnet EnOcean gateway SRC65-BACnet Thermokon combines two established network technologies to enable energyefficient and environmentally friendly “green buildings”. Das Gateway arbeitet mit dem Geräteprofil B-ASC und stellt eine Vielzahl an BIBBs zur Verfügung. Großen Wert legte Thermokon bei der Entwicklung auf die Einhaltung der BACnetStandards. Dies gewährleistet eine einwandfreie Interoperabilität, bereits existierende Projekte sind mühelos erweiterbar. Der SRC65-BACnet fungiert als Gateway zwischen der drahtlosen LowPower-Technologie von EnOcean und BACnet. During the indoor development great importance was given to compliance with the BACnet standards, thus, guaranteeing smooth interoperability and easy modification of existing projects. The SRC65-BACnet is designed as a gateway between the wireless LowPowertechnology by EnOcean and BACnet. Die Gerätefunktion umfasst einen Funkempfänger für EnOcean Funktelegramme und wird gemeinsam mit anderen BACnet-Automationsstationen betrieben. Alle Parametrier- und Konfigurationseinstellungen sind über das BACnet-Netzwerk möglich. Anschluss an Automationsstation oder GLT Das verwendete und international standardisierte BACnet MS / T P Protokoll ermöglicht den Anschluss an Automationsstationen oder GLTs. Die Baudrate ist frei wählbar und über DIP-Schalter einstellbar. Als Schnittstelle auf BusSeite dient der RS485-Standard. Die maximale Anzahl an Busteilnehmern gibt der verwendeten RS485 Transceiver vor und ermöglicht 128 Geräte Segment. Die Adressierung der Geräte zur Identifikation im Netzwerk erfolgt ebenfalls über DIP-Schalter und wird jedem Gerät individuell vergeben. Es lassen sich bis zu 32 EnOcean-basierte Geräte einlernen und verwenden. Nach dem erfolgreichen „Bekanntmachen“ von Sensoren und SRC65-BACnet ist unmittelbar ein kombiniertes Arbeiten mit beiden Netzwerktechnologien möglich. The function of the SRC65BACnet includes a radio receiver for EnOcean radio telegrams and is operated with other BACnet automation systems. All parameterization and configuration properties can be set over the BACnet network. Connection to automation station or BMS The protocol used is the international standardized BACnet MS / TP enabling the connection to automation stations or BMS. The baud rate is arbitrarily adjustable via a DIP switch. The RS485 standard works as an interface on the bus side. The maximum number of bus sharing units is preset by the RS485 transceiver and enables 128 devices / bus segment. The addressing of the devices for the identification in the network is also realized with a DIP-switch and is individually assigned to each device. The gateway works with the device profile BACnet Application Specific Controller (BASC) which offers a multiplicity of the BIBBs described above. It is possible to seamlessly connect and to use up to 32 EnOcean based devices. After a successful “learning-in” procedure of the sensors to the SRC65-BACnet, a combined operation with both network technologies is immediately possible. THERMOKON Sensortechnik GmbH www.thermokon.de [email protected] BACnet Europe Journal 12 04/10 59 Produkte Products Innovatives modulares System für mehr Flexibilität Innovative Modular System for more Flexibility Delta Controls stellt auf der light+building die neue enteliBUSTM Systemfamilie vor, eine neue Generation von Automationsstationen für Gebäudeautomation, Zutrittskontrolle und Beleuchtungssteuerung – modular, flexibel, erweiterbar. At light+building Delta Controls presents its new enteliBUSTM system family of modern automation stations for building automation, access control and lighting – modular, flexible, expandable. Das enteliBUSTM System ist eine frei programmierbare, modulare native BACnet® Controller Plattform mit beliebig erweiterbaren Ein- und Ausgängen und bietet eine beispiellose Flexibilität für mittlere und große ISP‘s. Herzstück des enteliBUSTM Automationssystems ist der enteliBUSTM Manager (eBMGR). Der eBMGR ist ein frei programmierbarer BACnet Building Controller (BBC) und stellt die primäre CPU Prozessorleistung, den lokalen Speicher und die externen Kommunikationsschnittstellen zur Verfügung. Das enteliBUSTM Automationssystem ist ein BACnet Router und unterstützt zahlreiche Kommunikationsvarianten: wie BACnet / IP, Ethernet, BACnet MS / TP sowie Fremdprotokolle wie z.B. Modbus / RTU unterstützt. Physikalische Einund Ausgänge für die Feldebene Die enteliBUSTM Module werden auf DIN-Hutschienen montiert, auf die enteliBUSTM Leiterplatten gesteckt und stellen die physikalischen E / A für die Feldebene zur Verfügung. Sie verfügen über 4 / 8 Ein- und Ausgänge und erlauben eine passgenaue Aufteilung. Die E / A Module können auch abgesetzt von der CPU in einen entfernten Schaltschrank eingebaut werden. Man kann die E / A Module im laufenden Betrieb austauschen (hot swappable) und sie haben optional einen Handschalter für die Notbedienung mit Positionsrückmeldung. E / A Module können beliebig gemischt und konfiguriert werden, um die entsprechende Anzahl E / A‘s für die benötigte Applikation, zu erhalten. Modulares Design bietet Flexibilität, einfacheren Service und geringere Kosten für zukünftige Upgrades und Erweiterungen. The enteliBUSTM Control System is a fully programmable, native BACnet, modular controller platform with expandable I / O that provides unparalleled flexibility to suit any medium to high density I / O application. The enteliBUSTM Manager (eBMGR) module is the ‘brain’ of an enteliBUSTM Controller System. The eBMGR is a fully programmable native BACnet Building Controller (B-BC) and contains the primary CPU processing power, memory storage, and the external communication ports. The enteliBUSTM automation engine is a BACnet router supporting multiple communication methods in- Der enteliBUSTM für moderne Raum- und Gebäudeautomation. For modern building and room automation - the automation station enteliBUSTM. 60 BACnet Europe Journal 12 04/10 Die enteliBUSTM E / A Module gibt es in verschiedensten Konfigurationen mit optionaler Handbedienung. The enteliBUSTM I / O modules comes in various configurations with optional manual override capability. cluding, BACnet IP, Ethernet, BACnet MS / TP, as well as 3rd party protocols such as Modbus / RTU. Physical input and output Field device connections The enteliBUSTM I / O modules are DIN rail mountable and are plugged onto an enteliBUSTM controller or expander backplane and provide the physical input and output field device connections. Each module supports 4 / 8 I / O points which allows granular I / O expansion. It is also possible to extend the I / O bus so that the I / O modules can be remotely installed from the CPU unit. I / O modules are hot swappable and have optional adjustable analog manual override with status feedback. I / O modules can be mixed and matched to provide the exact I / O mix required for a given application. Modular design provides flexibility, ease of service, and reduced cost for future upgrades and expansion. Delta Controls Germany [email protected] www.deltacontrols.de Produkte Products Elesta – Mit dem neuen BACnet Network Controller auf der light+building New Native BACnet Network Controller from Elesta at light+building Im Rahmen der light+building stellt Elesta building automation mit dem RCO500D-M / W eine neue Produktreihe der Produktfamilie Controlesta mit integrierter Web-Technologie vor. Within the framework of light+building Elesta building automation presents a new product range to their product family Controlesta, with the RCO500D-M / W with integrated Web technology. Der neue RCO500D-M / W mit integrierter Web-Technologie. New native BACnet Network Controller with Web technology from Elesta. Die Netzwerk-Controller RCO500D-M mit dem BACnet Geräteprofil B-BC unterstützen bei Bedarf neben den BACnet-Protokollen Ethernet, IP, MSTP und PTP auch die Protokolle Modbus, M-Bus, Wilo, Grundfos, Energesta-REN und andere. Diese vielfältigen Integrations- und Kommunikationsmöglichkeiten können simultan, in Abhängigkeit der freien Schnittstellen, genutzt werden. Integrierter Web-Server Die Controller-Variante RCO500D-W verfügt zusätzlich über einen integrierten Web-Server der die Visualisierung, Bedienung und Alarmierung mit einem StandardWebbrowser erlaubt. Mit dem integrierten Web-Server kann jederzeit auf die Anlage zugegriffen werden und das direkt in der Anlage am Schaltschrank oder per Fern- zugriff über das Intranet oder das Internet. Der integrierte Web-Server steht als neues Produkt-Feature auch in den BACnet-fähigen Master Controllern der Controlesta Baureihe RCO7.. zur Verfügung. Die HTML-Anlagenseiten werden komfortabel und effizient mit der Engineering-Software RCOtool erstellt. Die Baureihe RCO500DM / W ist durch die hohe Flexibilität für die heutigen und zukünftigen Anforderungen der modernen Gebäudeautomation ausgelegt. Ihre variable Ein- und Ausgangsbelegung, die vielfältigen Integrationsmöglichkeiten und die integrierte Web Technologie ermöglichen sowohl den Einsatz als Netzwerk-Controller in komplexen Anlagen als auch als abgesetzte Lösung für kommunikative Kleinanlagen. 62 BACnet Europe Journal 12 04/10 The network controller RCO500D-M with B-BC BACnet device profile supports BACnet protocols Ethernet, IP, MSTP and PTP on request. Additional protocols such as Modbus, M-bus, Wilo, Grundfos, Energesta REN, etc., are also supported. These various integration and communication abilities can be used simultaneously dependent on available interfaces. Integrated Web server The controller model RCO500D-W additionally has an integrated Web server for visualisation, operation and alarming via a standard web browser. The integrated Web server allows access to the installation at any time - directly at the control panel or with remote access via the Intranet or Internet. The integrated Web server is also available as a new prod- uct feature within the BACnet enabled Master Controller of the Controlesta range RCO7.. . The HTML pages are conveniently and efficiently designed with ELESTA’s engineering tool RCO-tool. The RCO500D-M / W series with its high flexibility is prepared for today’s and future requirements for modern building automation. The variable input and output design, the various integration abilities and the integrated Web technology makes the network controller usable for large sophisticated buildings as well as for multiple smaller buildings requiring remote communications. ELESTA GmbH building automation [email protected] www.elesta.de Produkte Products Funk-Kleinstellantrieb MD15-FTL Wireless MD15-FTL Small Motor Actuator Der Kieback&Peter Kleinstellantrieb MD15-FTL ist der erste Kleinstellantrieb, der den offenen EnOcean-Funk-Standard unterstützt. Er kommuniziert gemäß dem offenen und neutralen EnOcean-Aktor-Profil für Kleinstellantriebe. The Kieback&Peter MD15-FTL small motor actuator is the first small actuator that supports the open EnOcean wireless standard. It communicates in accordance with the open and neutral EnOcean acuator profile for small actuators. Der MD15-FTL basiert auf der Kieback&Peter MD15Plattform mit ihren vielen Nutzenvorteilen. Die Zusammenführung von Temperaturfühler / Sensor, Regler, motorischem Stellantrieb und innovativer Elektronik in einem Gerät bietet eine Anwendungsbreite vom klassischen Aktor bis zum einfachen Raumregler. Integration in Raumautomation In Kombination mit funkfähigen kabelgebundenen Raumreglern / G ateways übernimmt der MD15-FTL die Rolle eines intelligenten Stellantriebs für die Raumautomation. Der Raumcontroller kann über Funk und Kabel mit allen Komponenten der Raumautomation kommunizieren und deren Daten verarbeiten. Er übernimmt alle Regel- und Steuerungsfunktionen der Raumautomation und sorgt dafür, dass die Stellantriebe MD15-FTL optimal in das Gesamtsystem eingebunden werden. Bei dieser Lösung für Gebäude mit hohem Automatisierungsgrad ist ein direkter Zugriff von der Managementebene bis zu dem Funk-Stellantrieb möglich. Wo der Nutzer die Raumkonditionen individuell beeinflussen möchte, kann der MD15-FTL in Kombination mit einem Funkpartner (z. B. SolarFunk-Raumbediengerät) arbeiten. Am Raumbediengerät kann der Nutzer z. B. den Sollwert individuell einstellen oder ein Zeitprogramm hinterlegen. Über den EnOcean-Funkstandard werden diese Informationen an den MD15-FTL übertragen. Ein integrierter Regelalgorithmus ermöglicht durch die Softwarefunktionen eine präzise Raumregelung mit einfachster Bedienung und Konfiguration. Kostengünstige Raumtemperaturregelung Mit dem integrierten Messwertgeber und Regler kann der MD15-FTL auch ohne Integration in ein Raumautomationssystem arbeiten. Der eingestellte Sollwert wird automatisch eingehalten. Einsatzbereiche sind überall dort, wo mit wenig Installationsaufwand eine autarke und kostengünstige Raumtemperaturregelung realisiert werden soll. The MD15-FTL is based on the Kieback&Peter MD15 platform with its numerous user benefits. The combination of temperature probe / sensor, controller, motordriven actuator and innovative electronics in one device offers a range of applications from a classical actuator to a simple room controller. Integration in room automation MD15-FTL plays the role of an intelligent actuator for room automation in combination with compatible cable-based room controllers / gateways. The room controller can communicate with and process the data of all room automation components both wirelessly and via cables. It takes on all of the room automation’s control and regulating functions, and ensures that the actuators MD15-FTL are optimally integrated into the overall system. For buildings a with high degree of automation, this solution offers direct access from the management level to the wireless motor actuators. When the user wants room conditions to be individually controlled, the MD15-FTL can work in combination with a wireless partner (e.g. a SolarFunk room device). Via the room control unit, the user can individually adjust the set point or submit his own time schedule, for example. This information is transmitted to the MD15FTL wireless small actuator via the EnOcean wireless standard. An integrated control algorithm provides precise room control with the easiest operation and configuration by means of the software functions. Minimal installation effort With its integrated transducer and controller the MD15FTL can also work without integration in an room automation system. The setpoint is automatically observed. Application areas include anywhere self-sufficient and cost-effective temperature control is to be implemented with minimal installation effort. Kieback&Peter GmbH & Co. KG [email protected] www.kieback-peter.de Der neue Kleinstellantrieb MD15-FTL unterstützt den offenen EnOcean-Funk-Standard. The new MD15-FTL small motor actuator supports the open EnOcean wireless standard. BACnet Europe Journal 12 04/10 63 Produkte Products Protokollwandler mit vielen Möglichkeiten Versatile Protocol Converter 1979 veröffentlichte die Firma Gould-Modicon das Modbus-Protokoll. Ein Kommunikationsprotokoll, das nach dem Master-Slave-Prinzip konzipiert ist. Durch die Offenheit, leicht zu verstehende Mechanismen und Funktionen gewann es an Popularität und verbreitete sich in Industrie und vielen anderen Branchen. The Modbus protocol, a master-slave communication protocol, was published in 1979 by Gould-Modicon. As the protocol was open and its functions were easy to understand, it was soon accepted widely in industrial processes as well as other sectors. The Modbus protocol is still implemented in many of the latest smart devices. Noch heute haben viele kommunikationsfähige Geräte das Modbus-Protokoll implementiert. Oft genügt das Protokoll den heutigen Anforderungen nicht mehr, oder bestehende Systeme müssen mit einer übergeordneten BACnet Operator Workstation Software (BOWS) kommunizieren. Integration ermöglicht einwandfreie Kommunikation Zur Integration bietet sich das BACnet-zertifizierte CPU-Modul TROVIS 6610 an. Es verarbeitet ModbusInformationen (Funktionen 1, 2, 3, 4, 5, 6, 15 und 16) und stellt diese als BACnetObjekte zur Verfügung. Neben den eigenen SAMSONGeräten, z.B. TROVIS 5477 und TROVIS 5576, sind viele Partnersysteme, z.B. der Firmen Romutec Steuer- und Regelsysteme, Janitza Electronics, Iskra Avtoelektrika und Thermokon Sensortechnik in die Gerätebibliothek des Projektierungswerkzeugs „Grafische Projektierung TROVIS 6690“ aufgenommen worden. CPU-Modul mit vollem Funktionsumfang Modbus-Geräte, die nicht Bestandteil der Bibliot hek sind, werden dialoggeführt integriert. Neben der eigentlichen Protokollwandlung steht dem Anwender noch der volle Funktionsumfang des CPU-Moduls TROVIS 6610 zur Verfügung: Ein BACnet Building Controller (B-BC) mit 40 physikalischen Kanälen, umfangreicher HLK-Bibliothek, vollgrafischer Web-Server, E-Mail-Versand, GPRS-Unterstützung usw. Das Automationssystem setzt sich aus CPU-Modulen TROVIS 6610 und dezentralen Erweiterungsmodulen TROVIS 6620 (I / O -Modul) und TROVIS 6625 (I-Modul) zusammen. TROVIS 6625 ist ein neues Modul mit 20 binären Eingängen. Optional steht das Web-Terminal TROVIS 6615 mit berührungsempfindlichem Bildschirm (5,7“, 640 x 480 Pixel) zur Verfügung. In many cases, however, the protocol no longer suffices to meet today’s requirements, e.g. because existing systems must be upgraded to communicate with higher-level BACnet Operator Workstation Software (B-OWS). Integration allows perfect communication For integration, the BACnet-certified TROVIS 6610 CPU Module is available. The module processes Modbus data (functions 1, 2, 3, 4, 5, 6, 15 and 16) and makes them available as BACnet objects. In addition to SAMSON devices (e.g. TROVIS 5477 and TROVIS 5576 Controllers), products by many other manufacturers (e.g. Romutec, Janitza, Iskra and Thermokon) have already been integrated into the device library of the TROVIS 6690 Graphical Project Management Tool. Dialog boxes assist users in conveniently integrating Modbus devices that are not yet available in the library. TROVIS 6610 CPU Module with full scope of functions Apart from the actual conversion of protocols, users also benefit from the full scope of functions provided by the TROVIS 6610 CPU Module, i.e. a BACnet Building Controller (B-BC) with 40 physical channels, extensive HVAC library, graphical web server, email notification, GPRS support, etc. The automation system is composed of TROVIS 6610 CPU Modules and the distributed expansion modules TROVIS 6620 I / O Module and TROVIS 6625 I-Module. TROVIS 6625 is a new module with 20 binary inputs. Optionally, the TROVIS 6615 Web Terminal with touch screen (5.7", 640 x 480 pixels) is available. Projektierungswerkzeug „Grafische Projektierung TROVIS 6690“. TROVIS 6690 Graphical Project Management Tool. 64 BACnet Europe Journal 12 04/10 SAMSON Aktiengesellschaft [email protected] www.samson.de Produkte Products Mit dem neuen „Energy /// Perfect“ zu mehr Durchblick “Energy /// Perfect” for a Clear View Energiekosten steigen stetig. Transparenz über die Verursacher der Energiekosten ist notwendig, um trotz absehbarer Preissteigerungen Kosten senken und auf einem niedrigen Niveau halten zu können. Energy costs are steadily increasing. A clear view about the reasons for energy costs becomes necessary to lower the energy costs and keep them at a low level in the long run. Für die lokale Aufzeichnung der Verbrauchsdaten steht der Energy /// Saver zur Verfügung. Das Gerät basiert auf dem bekannten MBS Universal-Gateway und bietet neben einer BACnet / I P und MS / T P Schnittstelle zusätzlich die Möglichkeit, Zählerdaten über das M-Bus Protokoll aufzuzeichnen. Über den integrierten Webserver können bereits lokal liegenschaftsbezogene Auswertungen durchgeführt werden. Für kleine Anlagen oder einzelne Liegenschaften reicht diese Lösung bereits als Basis für ein umfassendes Energiemanagement aus. Mit einem optionalen Modem ausgerüstet, können bei Bedarf auch Alarme als SMS-Nachrichten an Mobiltelefone gesendet werden oder der Zugriff auf das Sys tem über das öffentliche Telefonnetz bereitgestellt werden. Transparenz und globaler Überblick Sollen mehrere Liegenschaften im direkten Überblick angezeigt werden oder steht das Benchmarking (Vergleich von ähnlichen Liegenschaften) im Vordergrund, so wird mit der PCSoftware Energy /// Viewer der umfassende Überblick über alle Liegenschaften ermöglicht. Hier können ebenfalls Kosteninformationen oder Vertragsdaten hinterlegt werden, so dass auf einfachste Weise Kostenoptimierungen möglich sind. Alle oben genannten Komponenten von Energy /// Perfect haben ein Ziel: Klarheit schaffen, um mit organisatorischen Maßnahmen den Verbrauch von Energie zu reduzieren. Daher folgt auf den Prozess des „Sichtbarmachens“ die Optimierung anhand der gewonnenen Messdaten. Energy /// Saver provides the local acquisition of data. The device is based on the well-known MBS UniversalGateway, and besides a BACnet / I P and MS / T P interface it provides the capability to capture metering data using the M-Bus protocol. Local facility analysis is provided by the integrated webserver. For small assets or single facilities this solution is often sufficient as a basis for energy monitoring and analysis. Equipped with an optional modem, alarms may be sent to mobile phones or access to the system can be provided through the public telephone network. Transparency and global overview If multiple facilities are to be shown in a survey or to provide a benchmark (for comparison of similar facilities) the software Energy /// Viewer allows a comprehensive overview about all your facilities. Additionally, costinformation or contract data can be added, so that costoptimization is made easy. All components of Energy /// Perfect follow the same goal: Provide clarify to allow energy optimization by organizational activities. After the process of visualizing consumption, the process of optimization according to the recorded data needs to follow. MBS GmbH [email protected] www.mbs-software.de BACnet Europe Journal 12 04/10 65 Produkte Products DoMooV Automation Server ermöglicht das einfache Managen von Daten BACnet server on BMS Standard Open Protocols Heutzutage haben BMS Systeme mit einer wachsenden Menge von Daten zu tun, die unterschiedliche offene BMS Standard Protokolle verwenden. Newron System bietet mit dem DoMooV Automation Server eine Software an, um verschiedene BMS Protokolle über eine Standard-BACnetSchnittstelle zu managen. Today’s BMS systems have to deal with a growing amount of data using several open BMS standard protocols. NEWRON SYSTEM offers new software managing several BMS protocols through a standard BACnet interface: DoMooV Automation Server. Derzeit existieren mehrere EN / ISO BMS Standard-Protokolle: BACnet, Lon, KNX, M-Bus plus Normen wie etwa MODBUS oder OPC. Systeme berücksichtigen immer mehr Protokolle, BACnet ist das Protokoll, das die Daten für das SCADA System sammelt. Der DoMooV AutomationServer verfügt über eine OPCServer Schnittstelle zur Verbindung von SCADA-Software mit Netzen, die mehrere BMS Kommunikationsprotokolle verwenden. Dies verhindert die Entwicklung eines Kommunikations-Treibers oder die Nutzung verschiedener OPC-Server je Protokoll: Da ist es klüger, mit einem einzigartigen Multi-Protokoll-OPCServer zu arbeiten. Verwaltung über eine Standard BACnetSchnittstelle Darüber hinaus bietet der DoMooV Automation Server die vollständige Verwaltung dieser Protokolle über eine Standard-BACnet-Schnittstelle. Die Software ermöglicht die Anbindung mehrerer FeldDaten an BACnet. Es ist nicht nur möglich, mehrere Protokolle (Lon, KNX, BACnet, M-Bus, Modbus) in BACnet zu überführen, sondern auch proprietäre oder nicht BMS Protokolle über die OPCSchnittstelle zu übersetzen. Für die „Hyperversion“, stellt der OPC-Client-Feld Treiber eine Schnittstelle mit einem nicht BACnet-SCADA zur Verfügung und überführt die Werte in ein StandardBACnet-Format. DoMooV Automation Server bietet ein SDK zur Entwicklung von Windows-Anwendungen unter Verwendung einer .NET-Programmierschnittstelle an. Mit diesem SDK kann man eine BMSWindow Anwendung programmieren, die das Lesen / Schreiben, die Alarmnachrichten, das Trending und die Terminplanung durch Unterstützung von BMS-Standard-Protokollen managt. Dies erleichtert der SCADATreiber oder die Tool Entwicklung. DoMooV Automation Server ist ein Windows-Programm, jedoch auch für Linux-Betriebssysteme verfügbar. Die Architektur des DoMooV Automation Servers von Nerwon. Architecture of the DoMooV Automation Servers by Newron. Today several EN / ISO BMS standard protocols exist: BACnet, LonWorks, KNX, M-Bus plus standards which are de facto included in BMS: MODBUS, OPC. Systems are becoming multiprotocol and BACnet is seen today as the protocol which gathers all the data for the SCADA system. The DoMooV Automation server has an OPC server interface to connect any SCADA software with networks using several BMS communication protocols. This avoids developing a communication driver for each protocol, or using a different OPC server for each protocol: this is indeed wiser for dealing with a unique multi protocol OPC server. In addition, the DoMooV Automation Server offers complete management of those protocols via a standard BACnet interface. The software allows interfacing several field data to BACnet. It is possible to translate into BACnet several standard field protocols (LonWorks, KNX, BACnet, M-Bus, Modbus) but also proprietary or non BMS protocols via the OPC interface. The OPC client field driver provides an interface with a non BACnet SCADA and translates the values to standard BACnet format to build «hypervision». The DoMooV Automation Server offers as SDK to develop Windows applications using a .NET programming interface. With this SDK you can program a BMS Windows application that can manage reading / writing, alarming, trending and scheduling on the supported BMS standard protocols. This eases SCADA driver or manufacturer tool developments. The DoMooV Automation Server is a Windows program but is also available for Linux OS. Serge LE MEN NEWRON SYSTEM serge.lemen@ newron-system.com BACnet Europe Journal 12 04/10 67 Produkte Products Gebäudeautomation erfolgreich gestalten Building Automation Created Successfully Mit dem Einzelraumregler COSMOS SRU und der BACnet Automationsstation COSMOS 600 Open Gebäude automation erfolgreich gestalten. Successful building automation with the room controller COSMOS SRU and the native BACnet Controller COMOS 600. Der neue Einzelraumregler COSMOS SRU kommuniziert standardmäßig über BACnet Schnittstelle mit anderen Geräten. Er verfügt über 16 Ein-/Ausgänge. Acht universal verwendbare Eingänge können sowohl als Digitaleingänge wie auch für den Anschluss marktüblicher analoger Sensoren genutzt werden. Zur Verfügung stehen ferner vier Universal- und vier Digitalausgänge (zwei bis 80mA, zwei bis 800mA). Darüber hinaus stehen diverse Standardapplikationen zur Verfügung, die lediglich parametriert werden müssen. Alle Parametrierungen können direkt über das BACnet Protokoll erfolgen. Die Geräte sind eingeordnet im Device Profil B-ASC (BACnet Application Specific Controller). Zu den geforderten BIBBs sind noch zusätzlich DS-COVU-B und DS-RPM-B implementiert. BACnet Automationsstation COSMOS 600 OPEN COSMOS 600 OPEN ist eine frei-programmierbare native BACnet Automationsstation (B-BC). Die Programmierung erfolgt mit der grafisch orientierten Funktionsplan-Software COSMOS FUP XL. Die COSMOS 600 OPEN verfügt standardmäßig über acht digitale Eingänge (mit Zählerfunktion), 12 digitale Ausgänge (Transistorausgänge je 80 mA), acht analoge Eingänge (auch als digitale Eingänge verwendbar) und vier analoge Ausgänge (0 bis 10 Volt). Ferner können weitere COSMOS IO Module bis zu 5 km Entfernung mittels CAN Bus angeschlossen werden. COSMOS 600 OPEN unterstützt die BBMD Funktionalität (BACnet Broadcast Management Device) und die Spezifikation B-BC (BACnet Building Controller). Sie kann gleichzeitig als BACnet-Client und BACnet-Server eingesetzt werden. Als Hardwarelayer stehen BACnet / I P, BACnet MS / T P und BACnet PTP zur Verfügung. In Verbindung mit dem integrierten Webserver COSMOview erhält man eine komfortable, grafische Bedienerführung über einen Webbrowser. Die Automationsstation COSMOS 600 OPEN unterstützt native das BACnet-Protokoll DIN EN ISO 16484-5. As a native BACnet controller supports COSMOS 600 OPEN the BACnet protocol DIN EN ISO 16484-5. The new single room controller COSMOS SRU communicates as standard with other devices via the BACnet interface. It disposes of 16 inputs and / or outputs. Eight universally usable inputs could be used as digital inputs as well as for the connection of mainstream analog sensors. There are four universal outputs and four additional digital outputs (two up to 80mA, two up to 800mA) available. Furthermore, several standard applications are available, which only have to be parameterized. All parametrizations can be made directly via the BACnet protocol. The devices are classified in the device profile B-ASC (BACnet Application Specific Controller). In addition to the required BIBBS, DS-COVU-B and DS-RPM-B are also implemented. BACnet controller COSMOS 600 OPEN COSMOS 600 OPEN is a freely-programmable native Der Einzelraumregler COSMOS SRU von DEOS kommuniziert standardmäßig über die BACnet Schnittstelle. The new single room controller COSMOS SRU communicates as standard with other devices via BACnet. 68 BACnet Europe Journal 12 04/10 BACnet controller (B-BC). The programming is effected with the graphically-oriented programming software COSMOS FUP XL. The COSMOS 600 OPEN has eigth digital inputs (with parameters), 12 digital outputs (transistor outputs each 80mA), eight analog inputs (also useable as digital inputs) and 4 analog outputs (0 up to 10 volts). Furthermore, additional COSMOS IO modules up to a distance of 5 Km can be connected via CAN-Bus. COSMOS 600 OPEN supports the BBMD functionality (BACnet Broadcast Management Device) and the specification B-BC (BACnet Building Controller). It can be used at the same time as BACnet-Client and as BACnet-Server. As hardware layer BACnet / I P, BACnet MS / T P and BACnet PTP are available. In connection with the integrated webserver COSMOview you get convenient, graphical operator guidance via one web browser. DEOS AG [email protected] www.deos-ag.com BACnet global Chinesische Gebäudeautomation integriert BACnet BACnet Integrated into Chinese Building Automation Die leistungsstarke Integration der Gebäudeautomation und die erwiesene Steigerung der Energieeffizienz öffneten der BACnet Technologie das Tor zum chinesischen Markt. Unter dieser Erkenntnis stand das erste unabhängige BACnet Forum in China. Das Forum fand am 20. Oktober 2009 in Beijing statt. Über 170 BACnet Nutzer aus China und der ganzen Welt diskutierten das technische, ökonomische und ökologische Potenzial des Standards. BACnet’s powerful building automation integration and proven results in energy efficiency have led this technology to be a leading sustainable solution for the Chinese market. This was the common spirit at the first independent BACnet Forum in China. The forum was held in Beijing on October 20th, 2009. More than 170 BACnet users from China and all over the world discussed the technical, economic and ecological potential. H. Michael Newman eröffnete das erste unabhängige BACnet Forum in Beijing. The first independent BACnet Forum was opened by H. Michael Newman H. Michael Newman, Schöpfer von BACnet und Gründer des BACnet Standardisierungskomitees, eröffnete das BACnet Forum Beijing. Die Teilnehmer wurden von Huang Jiusong willkommen geheißen, dem Leiter des Building Development Centre of Science and Technology Committee of Ministry of Housing and Urban-Rural Development of the Peoples Republic of China. H. Michael Newman, creator of BACnet and founder of the BACnet standardization committee, opened the BACnet Forum Beijing. The participants were welcomed by Huang Jiusong, Head of the Intelligent Building Development Centre of Science and Technology Committee of Ministry of Housing and Urban-Rural Development of the Peoples Republic of China. Global Player sind involviert BACnet Experten von weltweit operierenden Unternehmen stellten Entwicklungen und Anwendungen der neuen Technologie vor. Auf dem Forum gab die BACnet Interest Group China (BIG-CN) ihre Gründung bekannt. Ein vierköpfiger Vorstand und ein Beirat vertreten die 15 Gründungsmitglieder. Ziel des BACnet Forums Beijing war die Einführung der fortschrittlichen BACnet Technologie und die Präsentation der westlichen Industrie auf dem chinesischen Markt. Ein ungeahnter Andrang von chinesischen Experten, Technologieanwendern, Investoren, Beratern, Entwicklern, Herstellern und Systemintegratoren war zu verzeichnen. Das nächste BACnet Forum in China wird im Oktober 2010 in Shanghai stattfinden. Global BACnet players involved BACnet experts of world spanning companies introduced developments and applications of the new technology. At the forum the BACnet Interest Group China (BIG- CN) announced its foundation. 15 founding members have elected a board and an advisory board. The target of the BACnet Forum Beijing was to introduce the advanced BACnet technology and products from the western industry to the Chinese market. An unforeseen large number of Chinese experts, technology operators, investors, consultants, developers, manufacturers, system integrators, specifiers, owners and users was present. The next BACnet forum in China will be held in October 2010 in Shanghai. BACnet Europe Journal 12 04/10 69 BACnet global Liaison Committee fördert gemeinsame Aktionen Liaison Committee Conveys Collaborative Activities Am Sonntag vor der AHR Expo traf sich in Orlando das transatlantische BACnet Liaison Committee. Die Vertreter von BACnet International (BI) und von der BACnet Interest Group Europe (BIG-EU) nutzten das Gespräch zur Abstimmung der Aktionen, die den Gebrauch BACnet Standards weiter fördern. The transatlantic BACnet Liaison Committee met in Orlando on the Sunday before the AHR Expo. Representatives of BACnet International (BI) and the BACnet Interest Group Europe (BIG-EU) took advantage of the meeting to coordinate activities for further developing the use of the BACnet Standard. Der neue BTL Manager Duffy O’Craven berichtete über die Akkreditierung des BI Testlabors SoftDEL in Mumbai. Damit ist neben dem WSPLab in Stuttgart ein zweites Labor für BACnet Konformitätstests akkreditiert. Die Einheitlichkeit der Tests wird durch die Testsoftware unterstützt. Beide Labors setzen das BACnet Test Framework (BTF) ein. Auch die Gerätehersteller können es für ihre Vortests nutzen. Bis Ende Januar hatten sich vier BIG-EU Mitglieder mit dem Beitritt zur BI die weitere Nutzung der BTL-Marke gesichert. Mit einer zusätzlichen Ermäßigung für BIG-EU Mitglieder der Kategorie D soll die Aufnahme in die BI für kleine und mittlere Unternehmen attraktiver werden. Um die Vielfalt der BACnet Angebote darzustellen, lud die BIG-EU alle BI Mitglieder auf den BACnet Gemeinschaftsstand der light+building ein. Die BI wird sich zudem als Institu- tion präsentieren – ebenfalls auf Einladung der BIG-EU. H. Michael Newman bot allen BIG-EU Mitglieder an, sich an der Sammlung von Referenzprojekten auf der BI Website (www.bacnetinternational.org) zu beteiligen und dort auch den BACnet Kalender zu nutzen. testing software. Both laboratories use the BACnet Test Framework (BTF). Manufacturers can use it for their pre-testing as well. As of the end of January, four BIG-EU members joined BI, thus securing the further use of the BTL brand. An additional discount for Category D BIG-EU members is meant to make admission to BI more attractive for small and mid-sized firms. BIG-EU has invited all BI members to the BACnet joint booth at light&building in order to demonstrate the wide variety of BACnet products on offer. BI will present itself as an institution – also at the invitation of the BIG-EU. H. Michael Newman offered that all BIGEU members participate in the collection of reference projects on the BI website (www.bacnetinternational. org) and that they use the BACnet calendar as well. A additional topic was the foundation of the BACnet Interest Group China (BIGCN). It was created in last October with the joint support of BI and the BIG-EU. With the upcoming BACnet Forum Shanghai in October this year the application of the BACnet standard in China will be further supported. Ein weiteres Thema war die Gründung der BACnet Interest Group China (BIGCN). Sie war mit gemeinsamer Unterstützung durch die BI und die BIG-EU im letzten Oktober zustande gekommen. Mit dem anstehenden BACnet Forum Shanghai im Oktober dieses Jahres wird die Anwendung des BACnet Standards in China weiter unterstützt. The new BTL manager, Duffy O’Craven reported on the accreditation of the BI testing laboratory SoftDEL in Mumbai. Along with the WSPLab in Stuttgart this is the second laboratory accredited for BACnet conformance tests. The uniformity of the tests is supported by 70 BACnet Europe Journal 12 04/10 Im Bild (v.l.n.r.) H. Michael Newman (BI), Bruno Kloubert (BIG-EU), Frank Schubert (BIG-EU), Steven T. Bushby (BI), Raymond Rae (BI), Hans Symanczik (BIG-EU), Bill Swan (BI), Duffy O’Craven (BI), Andy McMillan (BI). In the picture (left to right) H. Michael Newman (BI), Bruno Kloubert (BIG-EU), Frank Schubert (BIG-EU), Steven T. Bushby (BI), Raymond Rae (BI), Hans Symanczik (BIG-EU), Bill Swan (BI), Duffy O’Craven (BI), Andy McMillan (BI). BACnet global Grüner Lichtblick auf der AHR Expo A Green Ray of Hope at the AHR Expo Auf der AHR Expo war das große Interesse an „grünen“, nachhaltigen Produkten und Technologien sichtbar. Vom 25.-27. Januar kamen 28.500 Besucher zur größten HLK Messe Nordamerikas nach Orlando, acht Prozent mehr als auf der letzten AHR Expo in Orlando 2005. A considerable interest in “green” sustainable products and technologies at the AHR Expo was quite obvious. From 25-27 January 28,500 visitors came to Orlando for the biggest HVAC fair in North America, eight percent more than at the last AHR Expo in Orlando in 2005. Die wachsende Nachfrage nach „grüner“ Gebäudetechnik ist eine enorme Chance und Herausforderung für den BACnet Standard, legt er doch die vielleicht wichtigste Basis zum Energiesparen. Erst die Integration aller Gebäudesysteme ermöglicht eine intelligente Abstimmung von Beschattungs-, Heizungs- und Klimasystemen, eine zentrale Dokumentation von Verbrauchsdaten, einen Ausbau des Energiemanagements und der Energie Services. BACnet International nutzte diese Chance und präsentierte sich auf ihrem Gemeinschaftsstand mit zehn Mitgliedern. The increasing demand for “green” building technology is both an enormous oppor- tunity and challenge for the BACnet standard, as it likely lays the most important groundwork for saving energy. Only the integration of all building systems enables an intelligent arrangement of systems for sun-blinds, heating and air conditioning; central documentation of consumption data; and the upgrading of both energy management and energy services. BACnet International has taken advantage of this opportunity and was represented by ten members at its joint booth. BACnet im VLT® HVAC Drive FC 102 Standard oder soll es mehr sein? Bitte besuchen Sie uns auf der Light & Building 2010 in Halle 9, Stand D10 www.danfoss.de/vlt 2x mehr Flexibilität BACnet ist ab Mai 2010 standardmäßig in die Frequenzumrichter VLT® HVAC Drive FC 102 integriert. Mehr Funktionen zur Entlastung der übergeordneten Steuerung bietet die BACnet advanced Option. Danfoss GmbH, VLT Antriebstechnik Carl-Legien-Straße 8, 63073 Offenbach Telefon: 069 8902-0, E-Mail: [email protected] BACnet global Der BACnet Standard erobert den Nahen Osten The BACnet Standard Shines in the Middle East Im Rahmen der diesjährigen Big 5 in Dubai vom 22.25.11.2010 wird ein Treffen von BACnet Herstellern aus Europa, den USA und dem Mittleren Osten stattfinden. Ziel ist es, die Aktivität der BACnet Middle East und sich ergebene Synergien zwischen den einzelnen Gruppen zu fördern As part of this year’s Big 5 in Dubai from 22-25 November, 2010 there will be a meeting of BACnet manufacturers from Europe, the USA and the Middle East. The aim is to promote BACnet Middle East activity and the growing synergies among the different groups. Dubai ist für den Handel mit den weiterhin boomenden Wirtschaftsräumen in Indien, China und Nordafrika, aber auch in Saudi-Arabien, Abu Dhabi und Kuwait ein bevorzugter Standort. Zwischen den BACnet Anwendern dieser Länder und den Mitgliedern der großen BACnet Interest Groups in Europa und den USA sollen nützliche Relationen entstehen. Dubai is the preferred center of business for the booming markets in India, China and North Africa as well as in Saudi Arabia, Abu Dhabi and Kuwait. Advantageous relationships ought to be created between BACnet users in these countries and the members of the large BACnet Interest Groups in Europe and the US. BACnet kommt zur Weltausstellung nach Shanghai BACnet Will be at the World Exposition in Shanghai Auf der zweiten Vorstandsund Beiratssitzung der BACnet Interest Group China (BIG-CN), die am 9. März in Beijing stattfand, wurde der Termin für das angekündigte BACnet Forum Shanghai verabschiedet. Mitte Oktober, in der 43. Kalenderwoche, lädt die BIG-CN alle chinesischen Experten und Anwender der offenen Gebäudekommunikation in die bedeutendste Industriestadt der Volksrepublik China ein. Shanghai ist vom 1. Mai bis 31. Oktober die Heimat der Weltausstellung „Expo 2010 Shanghai China“. Zur bisher größten Weltausstellung aller Zeiten werden 70 Millionen Besucher erwartet. 240 angemeldete Länder sind schon heute ein Rekord. Im Städtedreieck Shanghai Hangzhou - Suzhou werden viele ehrgeizige Infrastruktur- und Wohnungsbauprojekte verwirklicht. Mit dem Forum holt China den BACnet Standard mitten in das mächtige ökonomische Zentrum. Weitere Information auf www.bacnetforum. org 72 BACnet Europe Journal 12 04/10 At the second board and advisors meeting of the BACnet Interest Group China (BIGCN), which took place on 9 March in Beijing, the date for the announced BACnet forum Shanghai was approved. In mid-October, in the 43rd calendar week, BIG-CN invites all Chinese experts and users of open building communication to the most important industrial city of the People’s Republic of China Shanghai will be the home of the “Expo 2010 Shanghai China” world exposition between 1 May and 31 October. 70 million visitors are expected to come to the largest world exposition ever. With 240 registered countries a record has already been set. Many ambitious infrastructure and apartment building projects have been realized in the region of the three cities Shanghai, Hang Zhou and Su Zhou. With the forum China is placing the BACnet Standard right in the middle of this economically strong region. Further information can be found at www.bacnetforum.org. BACnet Interest Group Europe GebäudeEffizienz Paris – Efficacité énergétique du Bâtiment – Dialogue 2010 Paris Frankreich führt mit der „Régulation Thermique - RT 2012“ den Niedrigenergiestandard für Neubauten ein. Mit Spannung erwartet die Baubranche die Veröffentlichung der neuen Energieeffizienz-Vorschrift im Juni 2010. Am 22. Juni treffen sich in Paris die französischen Experten und die Anwender intelligenter Gebäudetechnik zur Bestimmung des Status quo. In einem Dialog zur Energieeffizienz von Gebäuden („Efficacité énergétique du Bâtiment“) geht es um den Werterhalt von Immobilien, die Modernisierung öffentlicher Gebäude und das Wirtschaftspotenzial, das von den neuen europäischen und nationalen Standards ausgeht. France is implementing the low energy standard for new buildings with its “Régulation Thermique - RT 2012”. The building industry is eagerly awaiting the publishing of this new energy efficiency directive in June, 2010. On 22 June, French experts and users of intelligent building technology will meet in Paris to ascertain the status quo. The dialogue on energy efficiency in buildings (“Efficacité énergétique du Bâtiment”) is about maintaining the value of buildings, the modernization of public buildings and the economic potential which arises from the new European and national standards. Der Dialog in Paris ist das französische Pendant zum GebäudeEffizienz Dialog Frankfurt, der in diesem Jahr zum dritten Mal die Anwender, Planer und Anbieter energieeffizienter Gebäudetechnik zusammenbringt. Kooperationspartner sind auf nationaler Ebene die BACnet-, KNX- und LonMark-Organisationen gemeinsam mit dem französischen HLK-Verband ACR. Auf europäischer Ebene vertreten sind eu.bac (European building automation controls association), eu.ESCO (European association of energy service companies) sowie die BIG-EU (BACnet Interest Group Europe). Das französische Umweltprogramm „Grenelle de l’environnement“ fördert die Energieeffizienz von Wohnungen und öffentlichen Gebäuden, um den Energieverbrauch in Frankreich bis 2020 um über ein Drittel zu senken. 440 Milliarden Euro Fördermittel sind angesetzt; davon geht fast die Hälfte in die Baubranche. Rund um das Thema Energieeffizienz wird sich der Markt rasant entwickeln. Der Dialog „Efficacité énergétique du Bâtiment“ ist Treffpunkt für Investoren, Planer, Berater, Facility Manager und die Anbieter energieeffizienter Technologien und Services. Hochkarätige Referenten bieten französischen und europäischen Perspektiven aus erster Hand. The dialogue in Paris is the French counterpart to the GebäudeEffizienz (Building Efficiency) dialogue in Frankfurt, which brought together users, planners and providers of energy-efficient building technology for the third time. The organisations of BACnet, KNX and LonMark as well as the French HLK association ACR are cooperation partners on the national level. eu.bac (European Building Automation Controls Association), eu.ESCO (European Association of Energy Service Companies and BIG-EU (BACnet Interest Group Europe) are represented on the European level. The French environmental program “Grenelle de l’environnement” sponsors energy efficiency in apartments and public buildings, in order to lower the energy consumption in France by more than one-third before 2020. 440 billion Euros in subsidies have been applied, almost half of which will used in the building industry. The energy efficiency market will develop rapidly. The “Efficacité énergétique du Bâtiment” dialogue is a meeting place for investors, planners, consultants, facility managers and providers of energy-efficient technologies and services. Prestigious speakers will offer first-hand French and European perspectives. Planer, Betreiber, Facility Manager und Investoren informierten sich auf der GebäudeEffizienz über den Einsatz intelligenter Gebäudeautomationen, Energie Service Modelle und die Trends von morgen. Planers, operators, facility managers and investors gatherd information on building efficiency through the use of building automation, energy service models an new trends. BACnet Europe Journal 12 04/10 73 BACnet Interest Group Europe interclima+elec spiegelt wachsenden BACnet Bedarf interclima+elec Reflects the Growing Demand for BACnet BACnet gewinnt in Frankreich an Fahrt. Auf der Interclima+elec, der größten französischen Messe für Gebäudetechik, war die Nachfrage nach Trainings, Produkten und offener Systemarchitektur groß. Die Installationszahlen steigen; kaum ein Nichtwohngebäude wird ohne BACnet geplant. Der Markt ist in Bewegung. BACnet is gaining momentum in France. The demand for training, products and open system architecture was quite large at interclima+elec, one of France‘s largest trade fairs for building services engineering. The number of installations is rising, hardly any non-residential buildings are planned without BACnet. The market is on the move. Auf dem zweiten, nun vergrößerten Stand der Association BACnet France vom 9. bis 12. Februar in Paris präsentierten neun Aussteller den nachhaltigen Nutzen ihrer BACnet Produkte. Der Stand wurde von zahlreichen Planern, Integratoren und Beratern besucht. An allen vier Messetagen gab es einen regen fachlichen Austausch. Nine exhibitors presented the lasting benefits of their BACnet products in Paris from 9 to 12 February at what was the second booth – this time much larger – for the BACnet France Association. The booth was visited by numerous planners, integrators and consultants. There was a lively professional exchange on all four days. BACnet Interest Group Europe Effiziente Gebäudetechnik³ Efficient Building Services Engineering³ Effiziente Gebäudetechnik³ – Drei Tage rund um die Betriebskosten schließen mit dem BACnet Forum ab. Planer und Betreiber berichten über die Stärken integrierter Systeme, den Nutzen moderner Finanzierungskonzepte und die Verbesserung der Standards. Technologie- und Serviceanbieter präsentieren nachhaltig effiziente Komponenten, Systeme und Dienstleistungen. Efficient building services engineering³ – three days about operating costs will make up the BACnet Forum. Planners and operators will report on the strengths of integrated systems, the benefits of modern finance concepts and the improvement of standards. Technology and service providers will present sustainably efficient components, systems and services. Die Betriebskosten stehen im Blickfeld des erweiterten Frankfurter GebäudeEffizienz Dialogs. Vom 8.-10. November finden an drei aufeinander folgenden Tagen in der Messe Frankfurt die LONCOM (8.11.), der GebäudeEffizienz Dialog (9.11.) und das 2. Deutsche BACnet Forum (10.11.) statt. Von der Raumautomation bis zur Leittechnik werden aktuelle Standards und Trends für effiziente Gebäude diskutiert. Das BACnet Forum ist den erweiterten Funktionen des Standards gewidmet. „Unser neues Konzept bietet dem Teilnehmer drei Tage rund um die Leistungen intelligenten Gebäudetechnik“, so Volker Röhl, Präsident der BACnet Interest Group Europe (BIG-EU) und Mitglied im Programmkomitee. Jan Spelsberg, LonMark Deutschland e.V., ebenfalls Programmkomitee-Mitglied erläutert: „Wo wir bisher eine technologieunabhängige Darstellung favorisierten, bieten wir nun wie gewünscht mehrere Ebenen.“ Weil weniger gebaut wird, gilt das Interesse der Bauwirtschaft vor allem der Effizienzsteigerung. Im Mittelpunkt steht der Werterhalt Dialog Frankfurt 2010 der Immobilien. Eine Sanierung bringt verbessertes Energiemanagement, eine spürbare Senkung der Betriebskosten – und das ohne Einbußen bei Komfort und Sicherheit. Sowohl bei öffentlichen als auch bei kommerziellen Gebäuden liegt hier ein enormes Potenzial. 250 Teilnehmer am GebäudeEffizienz Dialog 2009 haben diesen Trend bestätigt. Der einzige umfassende Wunsch war, noch mehr über die einzelnen Techniken zu erfahren. Nachdem die BACnet Interest Group Europe (BIGEU) und der LonMark Deutschland e.V. dem Veranstaltungskonzept zugestimmt hatten, beschloss auch das Programmkomitee des GebäudeEffizienz Dialogs, diesem Wunsch zu folgen. Operating costs are the focus of the expanded GebäudeEffizienz (Building Efficiency) dialogue in Frank- BACnet Europe Journal 12 04/10 75 BACnet Interest Group Europe Whenever open building automation is under discussion, talk turns to BACnet. And if it has to be modular, extensible and energy efficient as well, talk turns to SAUTER. furt. On three consecutive days from 8 to 10 November, 2010, LONCOM (8 Nov.), the GebäudeEffizienz Dialog (9 Nov.) and the 2nd German BACnet Forum (10 Nov.) will take place in Frankfurt. From room automation to control technology, current standards and trends for efficient building will be discussed. The BACnet Forum is dedicated to the expanded features of the standard. “Our new concept offers the participant three days on the benefits of intelligent building services engineering,” says Volker Röhl, President of the BACnet Interest Group Europe (BIGEU) and member of the program committee. Jan Spelsberg of the LonMark Germany Association, likewise a program committee member, explained: “Whereas we formerly favored a technology-independent presentation, we now offer multiple platforms as desired.” tion industry applies primarily towards increasing efficiency. The central focus is maintaining the value of real estate. Renovation brings about improved energy management, a significant reduction in operating costs – without sacrificing comfort and safety. Both in public and commercial buildings there is enormous potential. The 250 participants in the 2009 Building Efficiency Dialogue confirm this trend. The only comprehensive wish was to learn more about the particular technologies. After the BACnet Interest Group Europe (BIGEU) and the LonMark Germany Association agreed to the concept of the event, the program committee of the Building Efficiency Dialogue also decided to comply with this desire. Because less is being built, the interest of the construc- SAUTER EY-modulo 5: with BACnet/IP. Energy efficient, open and economical – module for module for module. Modular, native BACnet stations of the SAUTER EY-modulo 5 series are the intelligent solutions in every respect for any needs relating to building management and room automation. With its optimal function modules, integrated web connection and flexible room automation system, SAUTER sets new standards. Because it is freely programmable, SAUTER EY-modulo 5 provides perfect system integration (e.g. M-Bus, Modbus) and smooth operation. Find out more about its versatility: www.sauter-controls.com Systems Components Services 76 BACnet Europe Journal 12 04/10 Facility Management BACnet Interest Group Europe Investitions- und Betriebskosten senken Reducing Investment and Operating Costs Zum 2. Deutschen BACnet Anwender Forum lädt die BIG-EU am 10. November 2010 nach Frankfurt ein. Fünf Jahre nach dem ersten deutschen BACnet Forum – damals in Berlin – ist es Zeit, die erweiterten Möglichkeiten von BACnet aufzuarbeiten und die Nutzung als Basis für energieeffiziente Gebäude zu erklären. BIG-EU invites users to the second German BACnet user forum in Frankfurt on 10 November, 2010. Five years after the first German BACnet forum in Berlin it is time to refurbish the enhanced possibilities of BACnet and define its use as the basis of energy efficient buildings. Die neue Version des BACnet Standards, Anfang 2009 publiziert, unterstützt das Energiemanagement und die Einbindung von Energie Services. Insgesamt um sieben Punkte wurde der Standard gegenüber der Version von 2004 aufgewertet – darunter neue Wege der Internetnutzung, der Zutrittskontrolle und der Anbindung an ERP Systeme. Mit dem BACnet Forum Frankfurt stellt sich die BIG- EU der wachsenden Nachfrage nach BACnet Know-how auf dem deutschen Markt. Kaum eine Ausschreibung für Zweckbauten kommt ohne BACnet daher. Bei richtiger Anwendung des Standards steigt die Wertschöpfung bei den Beteiligten, während die Investitions- und Betriebskosten der Bauherren sinken. Weitere Information auf www. bacnetforum.org The new version of the BACnet standard, published in 2009, supports energy management and the integration of energy services. A total of seven items were added to the standard compared to the 2004 version. Among these are new methods for use of the Internet, access control and the connection to ERP systems. The BACnet forum Frankfurt is the BIG-EU’s answer to the increasing demand for BACnet know-how on the German market. Hardly any tenders for functional buildings are made without BACnet. With the proper application of the Standard the added value for those involved is increased, while builders’ investment and operating costs are reduced. You can find additional information at www.bacnetforum.org. Willkommen in der BIG-EU Welcome to the BIG-EU iSAtech GmbH Paul J. Jaß [email protected] www.isatech.de Die Firma iSAtech GmbH – intelligente Sensoren Aktoren technologie – wurde 1996 in Berlin von Dipl.-Ing. Paul Jaß gegründet. Als Kooperationspartner und Zulieferant entwickelt iSAtech vorrangig intelligente, modulare Steuerungssysteme, welche vernetzt und autark agieren. Speziell im Bereich der Vernetzung mit BACnet wurden Steuerungen für Wärmerückgewinnungsgeräte und applikative Rauminfogeräte in Form von graphischen Bedien- und Steuerungseinheiten für die sensorgesteuerte Regelung entwickelt. Ergänzt durch flexible E/AEinheiten (Heizungsventile, Fensterkontakte) und den iSAmanager zur Adressierung wird die einfache Integration in die BACnet Umgebung von iSAtech gewährleistet. Dabei stehen wir mit unserer langjährigen Felderfahrung von der Entwicklung, der Projektierung bis hin zur Fertigung unserem Kooperationspartner zur Seite. The company iSAtech GmbH – intelligent sensor actuator technology – was founded in 1996 in Berlin by Dipl.-Ing. Paul Jaß. As cooperation partner and supplier, iSAtech develops mainly intelligent, modular control systems, which can be networked and function autarkically. In the area of networking with BACnet, control systems were developed for waste heat recovery as well as prac- tical devices for collecting information about rooms in the form of graphical user and control units for sensor-powered regulation. The inclusion of flexible I/O units (heating valves, window contact sensors) and the iSAmanager for addressing make it easy to integrate iSAtech into the BACnet environment. With our many years of experience in the field we assist our cooperation partners from the development stage through project planning all the way to the manufacturing stage. BACnet Europe Journal 12 04/10 77 BACnet Interest Group Europe BACnet Kalender – Calendar of BACnet Events Datum Date Ort Location Veranstaltung Event Kontakt Information 11.-16.04.2010 Frankfurt, D BIG-EU booth at light+building Jochen Willems, MarDirect, [email protected] 29.04.2010 Dortmund, D BACnet im deutschen Markt – Working Group Meeting BIG-EU Office, [email protected] 18.05.2010 WTC Zürich, CH BACnet Academy Europe – international training session Britta von Helden, MarDirect, [email protected] 2010 09.-10.06.2010 Frankfurt, D BACnet VDI Training Frank Schubert, MBS GmbH, [email protected] Hans R. Kranz, HAKIngenieurberatung, [email protected] 22.06.2010 Paris, F Efficacité énergétique du Bâtiment Dialogue 2010 Maguy de Mercurio, [email protected], Tel. Paris: 01 46 89 67 25 Oktober 2010 Shanghai, CN BACnet Forum Shanghai Ivy Pan, MarDirect, [email protected] 20.09.2010 Luzern, CH WG-T and WG-M Meetings BIG-EU Office, [email protected] 20.09.2010 Luzern, CH General Meeting BIG-EU Office, [email protected] 21.09.2010 Luzern, CH Advisory Board Meeting BIG-EU Office, [email protected] 19.-20.10.2010 Düsseldorf, D BACnet VDI Training Frank Schubert, MBS GmbH, [email protected] Hans R. Kranz, HAKIngenieurberatung, [email protected] 09.11.2010 Frankfurt, D GebäudeEffizienz Dialog 2010 Jochen Willems, MarDirect, [email protected] 10.11.2010 Frankfurt, D 2. Deutsches BACnet Forum BIG-EU Office, [email protected] Joint BACnet booth at the Big 5 Jochen Willems, MarDirect, [email protected] 22.-25.11.2010 Dubai, UAE w ICS – InlineControlServer programmable modular controller multi|protocol multi functional Fidelio® hotel reservation BACnet® server / client LonMark® TP/FT-10 / IP-852 sysmik©2010 78 BACnet Europe Journal 12 04/10 sysmik.com Betriebskosten von Immobilien senken, durch: integrierte Systeme moderne Finanzierungskonzepte effiziente Komponenten Energy Services Dialog Frankfurt 2010 Kongressmesse für energieeffiziente Immobilien Werterhalt von Immobilien durch Sanierung verbessertesEnergiemanagement spürbareSenkungderEnergiekosten ohneEinbußenbeiKomfortundSicherheit Top Themen ökologischeQualitätvonGebäuden ökonomischeQualitätvonGebäuden funktionaleQualitätvonGebäuden Dienstag, GebäudeEffizienz Award ZumzweitenMalwird2010derGebäudeEffizienzAwardausgelobt.DasbesteAutomationsprodukt,dasbesteAutomationssystem unddereffizientesteServicewerdengesucht. Funktionalität,Energieeffizienz,KommunikationsfähigkeitundwirtschaftlicherNutzensind dieKriterien. 09. November 2010 Congress Center der Messe Frankfurt Information. Bewerbung. Anmeldung. www.gebaeudeeffizienz2010.de Partner VERBAND BERATENDER INGENIEURE … wir sehen uns. light+building2010 11.–16.April,Stand9.0,E30 … see you there. Gebäudemanagement mit BACnet® … Building management with BACnet® The Neutrino-GLT speaks native BACnet®, which makes it open for comprehensive system integration of the widest variety of equipment from different trades. The entire plant technology is transparent. In this way it is open for comprehensive system integration of trade spanning devices. It can be easily monitored, operated and optimized. Top performance and high security of operation, data and access come as a matter of course. www.kieback-peter.de Die Neutrino-GLT spricht nativ BACnet ®. Damit ist sie offen für umfassende Systemintegration unterschiedlichster Anlagen aus verschiedenen Gewerken. Die gesamte Anlagentechnik ist transparent. Sie kann einfach überwacht, bedient und optimiert werden. Große Leistungsfähigkeit und hohe Betriebs-, Datenund Zugangssicherheit sind selbstverständlich. Kieback&PeterGmbH&Co.KG,12347Berlin,Germany,Tel.:+4930600 95-0,E-Mail:[email protected]